SIO Argo Site:
Pump Diagnostics Page   



Serial= 3195 WMO= 5906925

Return

←PreviousNext→

Cycle 61 GMT 16/11/2024 18:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 20 15.11 444 134 0.13 / 238.59 2 4
2 3 1376.04 -1 15.43 0 0 0.00 / 238.59 2 4
3 3 1427.12 1 15.00 2341 35 0.17 / 238.63 2 14
4 7 2003.44 38 14.72 2940 1645 1.81 / 240.27 2 14
5 13 1626.40 18 14.77 2491 662 2.48 / 240.94 2 15
6 13 1057.56 18 14.87 1784 478 2.95 / 241.41 2 19
7 13 446.60 18 15.05 979 265 3.22 / 241.68 2 18
8 13 126.64 18 15.15 512 140 3.36 / 241.82 2 14
9 8 0.08 175 15.14 321 850 4.21 / 242.67 2 14
Average= 3.91
(KJ/cycle)

Cycle 60 GMT 7/11/2024 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 20 15.11 444 134 0.13 / 234.40 2 4
2 3 1376.60 -1 15.42 0 0 0.00 / 234.40 2 4
3 3 1438.68 1 15.00 2357 35 0.17 / 234.44 2 13
4 7 2011.04 38 14.73 2955 1654 1.82 / 236.09 2 12
5 13 1582.08 18 14.79 2453 653 2.48 / 236.74 2 16
6 13 1026.60 18 14.89 1745 468 2.94 / 237.21 2 17
7 13 429.64 18 15.06 958 260 3.20 / 237.47 2 18
8 13 112.24 18 15.16 494 135 3.34 / 237.61 2 12
9 8 0.08 175 15.14 322 853 4.19 / 238.46 2 22
Average= 3.91
(KJ/cycle)

Cycle 59 GMT 28/10/2024 6:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 20 15.11 472 143 0.14 / 230.24 2 3
2 7 2004.32 38 14.73 2940 1646 1.79 / 231.89 2 12
3 13 1571.36 18 14.80 2415 643 2.43 / 232.53 2 15
4 13 919.60 18 14.92 1605 431 2.86 / 232.96 2 18
5 13 586.40 18 15.01 1170 316 3.18 / 233.28 2 20
6 13 121.28 18 15.16 509 139 3.32 / 233.41 2 13
7 8 0.12 175 15.14 322 853 4.17 / 234.27 2 16
Average= 3.90
(KJ/cycle)

Cycle 58 GMT 18/10/2024 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 20 15.12 472 143 0.14 / 226.09 2 3
2 7 2003.48 38 14.72 2945 1647 1.79 / 227.74 2 11
3 13 1495.12 18 14.79 2336 622 2.41 / 228.36 2 15
4 13 1051.80 18 14.87 1768 473 2.89 / 228.83 2 17
5 13 443.44 18 15.06 979 265 3.15 / 229.10 2 17
6 13 108.48 18 15.15 492 134 3.28 / 229.23 2 16
7 8 0.16 175 15.14 326 864 4.15 / 230.10 2 21
Average= 3.90
(KJ/cycle)

Cycle 57 GMT 8/10/2024 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 20 15.12 459 139 0.14 / 221.88 2 3
2 7 2013.36 38 14.73 2963 1659 1.80 / 223.54 2 13
3 13 1585.92 18 14.78 2458 654 2.45 / 224.19 2 16
4 13 1000.68 18 14.90 1719 461 2.91 / 224.65 2 17
5 13 488.48 18 15.05 1047 284 3.20 / 224.94 2 19
6 13 157.76 18 15.16 565 154 3.35 / 225.09 2 16
7 8 0.12 175 15.14 324 858 4.21 / 225.95 2 22
Average= 3.90
(KJ/cycle)

Cycle 56 GMT 29/ 9/2024 0: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 20 15.12 469 142 0.14 / 217.72 2 5
2 7 2012.48 38 14.72 2963 1657 1.80 / 219.38 2 13
3 13 1583.84 18 14.78 2452 652 2.45 / 220.03 2 15
4 13 933.72 18 14.92 1621 435 2.89 / 220.46 2 17
5 13 409.00 18 15.07 934 253 3.14 / 220.72 2 20
6 13 171.96 18 15.15 585 160 3.30 / 220.88 2 16
7 8 0.00 175 15.14 326 864 4.16 / 221.74 2 19
Average= 3.89
(KJ/cycle)

Cycle 55 GMT 19/ 9/2024 5:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 19 15.12 478 137 0.14 / 213.47 2 4
2 7 2004.92 38 14.73 2942 1647 1.78 / 215.12 2 14
3 13 1565.76 18 14.80 2415 643 2.43 / 215.76 2 14
4 13 1083.32 18 14.87 1812 485 2.91 / 216.25 2 18
5 13 541.56 18 15.03 1121 303 3.22 / 216.55 2 20
6 13 152.60 18 15.15 568 155 3.37 / 216.70 2 15
7 8 -0.20 175 15.15 329 872 4.24 / 217.58 2 23
Average= 3.89
(KJ/cycle)

Cycle 54 GMT 9/ 9/2024 11:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 20 15.11 471 142 0.14 / 209.23 2 4
2 7 2004.64 38 14.71 2945 1646 1.79 / 210.88 2 12
3 13 1482.20 18 14.80 2328 620 2.41 / 211.50 2 16
4 13 960.16 18 14.90 1662 446 2.85 / 211.95 2 20
5 13 475.36 18 15.04 1018 276 3.13 / 212.22 2 21
6 13 143.96 18 15.15 544 148 3.28 / 212.37 2 16
7 8 0.04 175 15.14 327 866 4.14 / 213.24 2 15
8 14 0.04 20 15.12 322 97 4.24 / 213.33 3 22
Average= 3.88
(KJ/cycle)

Cycle 53 GMT 30/ 8/2024 17:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 20 15.13 449 136 0.14 / 204.96 2 4
2 3 1381.68 -1 15.40 0 0 0.00 / 204.96 2 4
3 3 1429.04 1 15.01 2328 35 0.17 / 204.99 2 13
4 7 2008.04 38 14.73 2949 1651 1.82 / 206.64 2 12
5 13 1680.28 18 14.78 2564 682 2.50 / 207.32 2 14
6 13 996.32 18 14.90 1713 459 2.96 / 207.78 2 19
7 13 510.68 18 15.04 1082 293 3.26 / 208.08 2 22
8 13 126.72 18 15.16 524 143 3.40 / 208.22 2 15
9 8 0.00 175 15.15 329 872 4.27 / 209.09 2 17
Average= 3.87
(KJ/cycle)

Cycle 52 GMT 20/ 8/2024 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 19 15.15 454 131 0.13 / 200.82 2 4
2 3 1417.68 1 15.03 2300 35 0.17 / 200.85 2 12
3 7 2007.24 38 14.73 2943 1647 1.81 / 202.50 2 13
4 13 1467.52 18 14.81 2300 613 2.43 / 203.11 2 16
5 13 1001.64 18 14.91 1717 461 2.89 / 203.57 2 18
6 13 416.12 18 15.07 938 254 3.14 / 203.83 2 20
7 13 139.64 18 15.16 530 145 3.29 / 203.97 2 16
8 8 0.08 175 15.15 320 848 4.13 / 204.82 2 25
Average= 3.86
(KJ/cycle)

Cycle 51 GMT 11/ 8/2024 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 19 15.12 472 136 0.14 / 196.66 2 3
2 7 2011.56 38 14.74 2951 1653 1.79 / 198.32 2 13
3 13 1413.16 18 14.85 2228 596 2.38 / 198.91 2 17
4 13 1154.76 18 14.88 1908 511 2.90 / 199.42 2 20
5 13 449.36 18 15.07 992 269 3.16 / 199.69 2 22
6 13 118.16 18 15.17 501 137 3.30 / 199.83 2 18
7 8 0.32 175 15.17 323 857 4.16 / 200.69 2 14
Average= 3.86
(KJ/cycle)

Cycle 50 GMT 1/ 8/2024 10:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 19 15.14 463 133 0.13 / 192.41 2 4
2 7 2006.72 38 14.75 2941 1648 1.78 / 194.06 2 13
3 13 1520.60 18 14.83 2359 630 2.41 / 194.68 2 17
4 13 978.32 18 14.94 1683 453 2.86 / 195.14 2 19
5 13 487.44 18 15.05 1059 287 3.15 / 195.42 2 21
6 13 146.04 18 15.17 544 149 3.30 / 195.57 2 17
7 13 17.08 18 15.21 360 99 3.40 / 195.67 2 10
8 8 -0.24 175 15.15 323 856 4.25 / 196.53 2 15
Average= 3.85
(KJ/cycle)

Cycle 49 GMT 22/ 7/2024 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 19 15.15 447 129 0.13 / 188.31 2 4
2 7 2004.40 38 14.75 2942 1649 1.78 / 189.95 2 15
3 13 1511.68 18 14.84 2350 628 2.41 / 190.58 2 18
4 13 950.00 18 14.93 1655 445 2.85 / 191.03 2 19
5 13 376.04 18 15.11 899 245 3.09 / 191.27 2 21
6 13 109.48 18 15.18 498 136 3.23 / 191.41 2 14
7 8 0.20 175 15.17 326 865 4.10 / 192.27 2 18
Average= 3.85
(KJ/cycle)

Cycle 48 GMT 12/ 7/2024 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 19 15.14 458 132 0.13 / 184.11 2 5
2 7 2012.48 38 14.75 2951 1654 1.79 / 185.76 2 14
3 13 1452.88 18 14.84 2279 609 2.39 / 186.37 2 18
4 13 1035.56 18 14.91 1758 472 2.87 / 186.84 2 19
5 13 640.12 18 15.01 1243 336 3.20 / 187.18 2 20
6 13 120.60 18 15.19 505 138 3.34 / 187.32 2 15
7 8 -0.08 175 15.17 324 860 4.20 / 188.18 2 18
Average= 3.84
(KJ/cycle)

Cycle 47 GMT 3/ 7/2024 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 19 15.14 459 132 0.13 / 180.03 2 4
2 7 2008.84 38 14.76 2955 1657 1.79 / 181.69 2 13
3 13 1484.24 18 14.85 2317 619 2.41 / 182.31 2 17
4 13 912.64 18 14.96 1614 435 2.84 / 182.74 2 20
5 13 374.12 18 15.11 881 240 3.08 / 182.98 2 21
6 13 113.08 18 15.19 497 136 3.22 / 183.12 2 17
7 8 0.00 175 15.17 323 857 4.08 / 183.98 2 19
Average= 3.83
(KJ/cycle)

Cycle 46 GMT 23/ 6/2024 8:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 19 15.14 471 135 0.14 / 175.73 2 3
2 3 1383.84 -1 15.44 0 0 0.00 / 175.73 2 3
3 3 1432.64 1 15.00 2342 35 0.17 / 175.77 2 15
4 7 2004.24 38 14.74 2937 1645 1.82 / 177.41 2 13
5 13 1513.84 18 14.83 2357 629 2.44 / 178.04 2 17
6 13 1066.04 18 14.91 1800 483 2.93 / 178.52 2 18
7 13 469.56 18 15.07 1012 275 3.20 / 178.80 2 22
8 13 125.64 18 15.17 520 142 3.34 / 178.94 2 14
9 13 17.92 18 15.20 362 99 3.44 / 179.04 2 17
10 8 0.12 175 15.16 325 862 4.31 / 179.90 2 24
Average= 3.83
(KJ/cycle)

Cycle 45 GMT 13/ 6/2024 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.00 19 15.14 505 145 0.15 / 171.55 2 5
2 7 2007.12 38 14.76 2948 1653 1.80 / 173.20 2 14
3 13 1538.72 18 14.84 2385 637 2.44 / 173.84 2 19
4 13 951.92 18 14.95 1647 443 2.88 / 174.28 2 19
5 13 519.92 18 15.06 1099 298 3.18 / 174.58 2 21
6 13 125.88 18 15.19 519 142 3.32 / 174.72 2 18
7 8 0.16 175 15.18 328 871 4.19 / 175.59 2 21
Average= 3.82
(KJ/cycle)

Cycle 44 GMT 3/ 6/2024 19:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 19 15.16 471 136 0.14 / 167.30 2 5
2 7 2007.08 38 14.74 2935 1644 1.78 / 168.94 2 13
3 13 1749.68 18 14.79 2638 702 2.48 / 169.64 2 16
4 13 978.04 18 14.94 1672 450 2.93 / 170.09 2 19
5 13 485.00 18 15.06 1044 283 3.21 / 170.37 2 20
6 13 98.32 18 15.18 492 134 3.35 / 170.51 2 18
7 8 0.16 175 15.18 337 895 4.24 / 171.40 2 22
Average= 3.81
(KJ/cycle)

Cycle 43 GMT 25/ 5/2024 1:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 19 15.18 436 126 0.13 / 163.13 2 4
2 7 2010.64 39 14.76 2942 1694 1.82 / 164.83 2 14
3 13 1570.56 18 14.82 2434 649 2.47 / 165.48 2 17
4 13 1018.12 18 14.93 1727 464 2.93 / 165.94 2 19
5 13 519.24 18 15.06 1079 292 3.23 / 166.23 2 21
6 13 116.92 18 15.20 494 135 3.36 / 166.37 2 17
7 8 0.12 165 15.18 316 791 4.15 / 167.16 2 27
Average= 3.80
(KJ/cycle)

Cycle 42 GMT 15/ 5/2024 6:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 19 15.17 449 129 0.13 / 159.01 2 4
2 3 1380.68 -1 15.45 0 0 0.00 / 159.01 2 4
3 3 1435.72 1 15.03 2336 35 0.16 / 159.05 2 14
4 7 2004.60 38 14.77 2941 1651 1.82 / 160.70 2 14
5 13 1515.32 18 14.87 2362 632 2.45 / 161.33 2 17
6 13 878.76 18 14.99 1561 421 2.87 / 161.75 2 21
7 13 407.88 18 15.12 932 254 3.12 / 162.00 2 20
8 13 89.52 18 15.22 460 126 3.25 / 162.13 2 15
9 13 21.40 18 15.23 357 98 3.35 / 162.23 2 9
10 8 0.04 165 15.20 311 780 4.13 / 163.01 2 18
Average= 3.79
(KJ/cycle)

Cycle 41 GMT 5/ 5/2024 11:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 19 15.16 455 131 0.13 / 154.95 2 4
2 7 2012.40 38 14.77 2946 1653 1.78 / 156.61 2 13
3 13 1519.24 18 14.87 2350 629 2.41 / 157.24 2 18
4 13 1022.68 18 14.94 1735 467 2.88 / 157.70 2 19
5 13 423.48 18 15.11 943 256 3.14 / 157.96 2 19
6 13 95.24 18 15.21 467 128 3.26 / 158.09 2 16
7 8 -0.12 165 15.20 317 795 4.06 / 158.88 2 20
Average= 3.78
(KJ/cycle)

Cycle 40 GMT 25/ 4/2024 17:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 19 15.17 438 126 0.13 / 150.81 2 4
2 3 1383.36 -1 15.46 0 0 0.00 / 150.81 2 4
3 7 2009.84 38 14.76 2933 1645 1.77 / 152.46 2 15
4 13 1474.48 18 14.85 2311 618 2.39 / 153.08 2 18
5 13 882.48 18 14.97 1557 420 2.81 / 153.50 2 19
6 13 503.80 18 15.07 1052 285 3.09 / 153.78 2 22
7 13 146.28 18 15.18 541 148 3.24 / 153.93 2 18
8 13 18.28 18 15.21 350 96 3.34 / 154.02 2 13
9 8 0.12 165 15.17 319 798 4.14 / 154.82 2 18
Average= 3.78
(KJ/cycle)

Cycle 39 GMT 15/ 4/2024 23: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 19 15.19 446 129 0.13 / 146.66 2 3
2 3 1373.52 -1 15.45 0 0 0.00 / 146.66 2 3
3 3 1424.76 1 15.05 2325 35 0.16 / 146.70 2 14
4 7 2004.08 38 14.78 2938 1650 1.81 / 148.35 2 14
5 13 1509.00 18 14.87 2340 626 2.44 / 148.98 2 18
6 13 955.72 18 14.97 1643 443 2.88 / 149.42 2 20
7 13 360.04 18 15.14 849 231 3.11 / 149.65 2 20
8 13 91.44 18 15.23 456 125 3.24 / 149.78 2 18
9 8 0.52 165 15.21 308 773 4.01 / 150.55 2 19
10 14 0.52 30 15.18 304 138 4.15 / 150.69 3 27
Average= 3.77
(KJ/cycle)

Cycle 38 GMT 6/ 4/2024 4:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 19 15.18 435 125 0.13 / 142.51 2 4
2 3 1373.08 -1 15.48 0 0 0.00 / 142.51 2 4
3 3 1444.64 1 15.04 2351 35 0.16 / 142.54 2 14
4 7 2006.20 38 14.79 2941 1653 1.81 / 144.19 2 14
5 13 1476.44 18 14.89 2295 615 2.43 / 144.81 2 18
6 13 985.72 18 14.98 1679 453 2.88 / 145.26 2 21
7 13 433.92 18 15.14 954 260 3.14 / 145.52 2 20
8 13 101.08 18 15.23 467 128 3.27 / 145.65 2 18
9 13 20.04 18 15.26 353 97 3.37 / 145.75 2 12
10 8 0.32 165 15.22 314 789 4.16 / 146.54 2 22
Average= 3.76
(KJ/cycle)

Cycle 37 GMT 27/ 3/2024 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 19 15.19 428 124 0.12 / 138.35 2 3
2 7 2007.04 38 14.79 2936 1650 1.77 / 140.00 2 13
3 13 1619.84 18 14.85 2493 666 2.44 / 140.66 2 17
4 13 963.68 18 14.99 1658 447 2.89 / 141.11 2 20
5 13 459.16 18 15.13 992 270 3.16 / 141.38 2 21
6 13 79.92 18 15.24 437 120 3.28 / 141.50 2 12
7 13 17.68 18 15.25 349 96 3.37 / 141.60 2 10
8 8 0.24 165 15.21 313 786 4.16 / 142.38 2 16
Average= 3.75
(KJ/cycle)

Cycle 36 GMT 17/ 3/2024 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 19 15.19 441 127 0.13 / 134.18 2 4
2 7 2012.64 38 14.80 2950 1659 1.79 / 135.84 2 12
3 13 1487.16 18 14.88 2304 617 2.40 / 136.46 2 16
4 13 946.88 18 14.99 1623 438 2.84 / 136.90 2 19
5 13 515.56 18 15.10 1057 287 3.13 / 137.18 2 19
6 13 111.04 18 15.24 474 130 3.26 / 137.31 2 14
7 8 0.32 165 15.22 306 768 4.03 / 138.08 2 22
8 14 0.32 30 15.20 307 140 4.17 / 138.22 2 20
Average= 3.74
(KJ/cycle)

Cycle 35 GMT 7/ 3/2024 22:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 19 15.20 448 129 0.13 / 130.10 2 3
2 3 1382.52 -1 15.49 0 0 0.00 / 130.10 2 3
3 3 1433.04 1 15.06 2342 35 0.16 / 130.14 2 12
4 7 2008.40 38 14.77 2941 1651 1.82 / 131.79 2 13
5 13 1519.52 18 14.87 2354 630 2.45 / 132.42 2 16
6 13 886.88 18 15.00 1553 419 2.86 / 132.84 2 19
7 13 409.24 18 15.13 909 248 3.11 / 133.09 2 19
8 13 80.88 18 15.23 431 118 3.23 / 133.20 2 16
9 13 19.60 18 15.24 339 93 3.32 / 133.30 2 11
10 8 0.04 165 15.21 302 758 4.08 / 134.06 2 16
Average= 3.72
(KJ/cycle)

Cycle 34 GMT 27/ 2/2024 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 19 15.19 451 130 0.13 / 125.95 2 3
2 3 1377.16 -1 15.49 0 0 0.00 / 125.95 2 3
3 3 1429.68 1 15.08 2317 35 0.17 / 125.98 2 12
4 7 2005.40 38 14.80 2942 1655 1.82 / 127.64 2 12
5 13 1536.52 18 14.87 2383 638 2.46 / 128.27 2 16
6 13 1000.56 18 14.97 1691 456 2.91 / 128.73 2 19
7 13 407.40 18 15.14 907 247 3.16 / 128.98 2 19
8 13 135.32 18 15.21 511 140 3.30 / 129.12 2 15
9 13 19.92 18 15.25 342 94 3.39 / 129.21 2 15
10 8 0.24 165 15.22 304 763 4.16 / 129.97 2 16
Average= 3.71
(KJ/cycle)

Cycle 33 GMT 17/ 2/2024 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 19 15.19 427 123 0.12 / 121.89 2 3
2 7 2009.60 39 14.78 2934 1691 1.81 / 123.58 2 13
3 13 1402.76 18 14.90 2201 590 2.40 / 124.17 2 17
4 13 938.32 18 14.98 1624 438 2.84 / 124.61 2 19
5 13 338.04 18 15.16 807 220 3.06 / 124.83 2 19
6 13 121.80 18 15.22 486 133 3.20 / 124.96 2 16
7 13 35.80 18 15.25 360 99 3.29 / 125.06 2 18
8 8 -0.08 165 15.22 301 756 4.05 / 125.82 2 14
Average= 3.70
(KJ/cycle)

Cycle 32 GMT 7/ 2/2024 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 19 15.21 425 123 0.12 / 117.84 2 3
2 7 2007.40 38 14.80 2929 1647 1.77 / 119.49 2 12
3 13 1542.64 18 14.87 2380 637 2.41 / 120.12 2 16
4 13 907.92 18 15.01 1570 424 2.83 / 120.55 2 19
5 13 418.24 18 15.14 923 252 3.08 / 120.80 2 19
6 13 142.92 18 15.22 516 141 3.22 / 120.94 2 15
7 13 23.64 18 15.25 338 93 3.32 / 121.03 2 11
8 8 -0.12 165 15.22 292 733 4.05 / 121.77 2 17
Average= 3.69
(KJ/cycle)

Cycle 31 GMT 28/ 1/2024 20:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 19 15.21 423 122 0.12 / 113.78 2 3
2 7 2004.88 39 14.80 2931 1692 1.81 / 115.47 2 13
3 13 1463.76 18 14.92 2277 612 2.43 / 116.08 2 16
4 13 879.04 18 15.03 1536 416 2.84 / 116.49 2 19
5 13 437.60 18 15.15 950 259 3.10 / 116.75 2 19
6 13 112.40 18 15.24 470 129 3.23 / 116.88 2 14
7 13 14.48 18 15.26 326 90 3.32 / 116.97 2 14
8 8 0.12 165 15.23 296 744 4.06 / 117.72 2 18
Average= 3.68
(KJ/cycle)

Cycle 30 GMT 19/ 1/2024 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 19 15.21 438 127 0.13 / 109.57 2 3
2 7 2003.20 39 14.80 2928 1690 1.82 / 111.26 2 13
3 13 1612.08 18 14.87 2461 659 2.48 / 111.91 2 15
4 13 1050.24 18 14.97 1753 472 2.95 / 112.39 2 18
5 13 494.00 18 15.12 1030 280 3.23 / 112.67 2 19
6 13 152.64 18 15.23 533 146 3.37 / 112.81 2 16
7 13 21.80 18 15.25 340 93 3.47 / 112.91 2 15
8 8 0.00 165 15.23 297 746 4.21 / 113.65 2 18
Average= 3.67
(KJ/cycle)

Cycle 29 GMT 9/ 1/2024 7:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 19 15.22 419 121 0.12 / 105.53 2 3
2 3 1377.96 -1 15.50 0 0 0.00 / 105.53 2 3
3 3 1429.92 1 15.09 2309 35 0.16 / 105.57 2 12
4 7 2006.40 38 14.79 2925 1644 1.80 / 107.21 2 13
5 13 1589.28 18 14.87 2427 650 2.45 / 107.86 2 15
6 13 1012.84 18 14.97 1708 460 2.91 / 108.32 2 19
7 13 365.36 18 15.17 838 229 3.14 / 108.55 2 18
8 13 145.92 18 15.23 519 142 3.28 / 108.69 2 16
9 8 -0.48 165 15.23 297 746 4.03 / 109.44 2 15
Average= 3.65
(KJ/cycle)

Cycle 28 GMT 30/12/2023 12:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 19 15.22 435 126 0.13 / 101.49 2 3
2 7 2005.88 38 14.81 2932 1650 1.78 / 103.14 2 13
3 13 1695.40 18 14.84 2556 683 2.46 / 103.83 2 15
4 13 971.60 18 14.99 1652 446 2.90 / 104.27 2 18
5 13 431.92 18 15.14 935 255 3.16 / 104.53 2 19
6 13 152.56 18 15.24 528 145 3.30 / 104.67 2 15
7 8 0.48 165 15.23 295 741 4.05 / 105.41 2 17
Average= 3.63
(KJ/cycle)

Cycle 27 GMT 20/12/2023 17:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 19 15.22 429 124 0.12 / 97.51 2 4
2 7 2005.16 38 14.82 2925 1647 1.77 / 99.16 2 13
3 13 1529.68 18 14.90 2351 631 2.40 / 99.79 2 16
4 13 979.12 18 15.00 1669 451 2.85 / 100.24 2 18
5 13 387.12 18 15.16 874 238 3.09 / 100.48 2 18
6 13 166.04 18 15.25 548 150 3.24 / 100.63 2 15
7 8 0.08 165 15.25 294 740 3.98 / 101.37 2 15
Average= 3.62
(KJ/cycle)

Cycle 26 GMT 10/12/2023 23:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 19 15.22 426 123 0.12 / 93.45 2 3
2 3 1370.92 -1 15.49 0 0 0.00 / 93.45 2 3
3 3 1427.00 1 15.09 2308 35 0.16 / 93.48 2 11
4 7 2012.28 38 14.81 2933 1651 1.81 / 95.13 2 13
5 13 1526.32 18 14.89 2353 631 2.44 / 95.76 2 16
6 13 1020.28 18 14.99 1713 462 2.90 / 96.23 2 18
7 13 459.80 18 15.14 974 265 3.17 / 96.49 2 19
8 13 170.84 18 15.23 554 152 3.32 / 96.64 2 15
9 8 0.16 165 15.24 295 742 4.06 / 97.39 2 15
Average= 3.61
(KJ/cycle)

Cycle 25 GMT 1/12/2023 4:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 19 15.22 441 128 0.13 / 89.37 2 3
2 3 1383.52 -1 15.51 0 0 0.00 / 89.37 2 3
3 3 1434.24 1 15.08 2311 35 0.16 / 89.40 2 11
4 7 2004.76 38 14.81 2918 1642 1.80 / 91.04 2 11
5 13 1528.80 18 14.90 2356 632 2.44 / 91.68 2 15
6 13 1084.32 18 14.98 1797 485 2.92 / 92.16 2 17
7 13 516.56 18 15.11 1053 286 3.21 / 92.45 2 18
8 13 116.92 18 15.24 477 131 3.34 / 92.58 2 14
9 8 -0.04 165 15.23 297 746 4.08 / 93.32 2 15
Average= 3.59
(KJ/cycle)

Cycle 24 GMT 21/11/2023 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 19 15.23 421 122 0.12 / 85.38 2 3
2 3 1380.48 -1 15.51 0 0 0.00 / 85.38 2 3
3 3 1438.72 1 15.07 2352 35 0.16 / 85.42 2 11
4 7 2008.76 38 14.83 2930 1651 1.81 / 87.07 2 11
5 13 1439.76 18 14.92 2234 600 2.41 / 87.67 2 14
6 13 1011.28 18 14.99 1696 458 2.87 / 88.13 2 17
7 13 446.08 18 15.16 949 259 3.12 / 88.39 2 17
8 13 79.96 18 15.28 417 115 3.24 / 88.50 2 12
9 8 0.12 165 15.25 294 740 3.98 / 89.24 2 18
Average= 3.57
(KJ/cycle)

Cycle 23 GMT 11/11/2023 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 19 15.23 437 126 0.13 / 81.27 2 3
2 7 2013.36 38 14.83 2937 1655 1.78 / 82.93 2 11
3 13 1429.80 18 14.95 2242 603 2.38 / 83.53 2 14
4 13 1011.56 18 15.01 1705 461 2.85 / 83.99 2 17
5 13 435.48 18 15.18 942 257 3.10 / 84.25 2 17
6 13 161.28 18 15.25 540 148 3.25 / 84.40 2 13
7 8 -0.28 165 15.26 290 730 3.98 / 85.13 2 26
8 14 -0.28 30 15.24 289 132 4.11 / 85.26 3 19
Average= 3.55
(KJ/cycle)

Cycle 22 GMT 1/11/2023 21:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 19 15.22 442 128 0.13 / 77.32 2 3
2 7 2010.52 38 14.84 2930 1652 1.78 / 78.97 2 11
3 13 1432.56 18 14.95 2243 604 2.38 / 79.58 2 15
4 13 1003.84 18 15.02 1699 459 2.84 / 80.04 2 17
5 13 392.24 18 15.19 888 243 3.09 / 80.28 2 17
6 13 80.92 18 15.28 425 117 3.20 / 80.39 2 13
7 8 0.40 165 15.25 299 752 3.96 / 81.15 2 16
Average= 3.53
(KJ/cycle)

Cycle 21 GMT 23/10/2023 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 19 15.25 437 127 0.13 / 73.34 2 4
2 7 2010.76 38 14.84 2930 1652 1.78 / 74.99 2 12
3 13 1580.28 18 14.93 2418 650 2.43 / 75.64 2 14
4 13 892.20 18 15.04 1556 421 2.85 / 76.06 2 17
5 13 406.80 18 15.17 914 250 3.10 / 76.31 2 18
6 13 82.88 18 15.27 436 120 3.22 / 76.43 2 13
7 8 0.00 165 15.26 303 763 3.98 / 77.19 2 16
Average= 3.51
(KJ/cycle)

Cycle 20 GMT 13/10/2023 8:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 19 15.24 427 124 0.12 / 69.26 2 3
2 3 1372.12 -1 15.52 0 0 0.00 / 69.26 2 3
3 3 1421.20 1 15.12 2297 35 0.16 / 69.29 2 13
4 7 2004.80 38 14.85 2918 1647 1.81 / 70.94 2 13
5 13 1461.84 18 14.96 2267 610 2.42 / 71.55 2 16
6 13 1010.16 18 15.02 1701 460 2.88 / 72.01 2 18
7 13 610.12 18 15.12 1178 321 3.20 / 72.33 2 20
8 13 129.84 18 15.28 493 136 3.33 / 72.47 2 15
9 8 -0.12 165 15.26 295 743 4.07 / 73.21 2 19
Average= 3.49
(KJ/cycle)

Cycle 19 GMT 3/10/2023 14:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 19 15.24 424 123 0.12 / 65.34 2 3
2 7 2012.32 38 14.84 2920 1647 1.77 / 66.99 2 13
3 13 1457.68 18 14.94 2254 606 2.38 / 67.60 2 16
4 13 975.88 18 15.01 1651 446 2.82 / 68.04 2 19
5 13 379.68 18 15.18 855 234 3.06 / 68.28 2 18
6 13 129.72 18 15.26 484 133 3.19 / 68.41 2 14
7 8 -0.04 165 15.25 289 727 3.92 / 69.14 2 16
Average= 3.46
(KJ/cycle)

Cycle 18 GMT 23/ 9/2023 19: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 19 15.23 430 124 0.12 / 61.38 2 4
2 7 2011.68 38 14.85 2921 1648 1.77 / 63.03 2 13
3 13 1532.16 18 14.93 2344 630 2.40 / 63.66 2 16
4 13 987.44 18 15.03 1673 453 2.86 / 64.11 2 18
5 13 399.00 18 15.19 884 242 3.10 / 64.36 2 19
6 13 127.08 18 15.26 488 134 3.23 / 64.49 2 14
7 8 0.20 165 15.26 290 730 3.96 / 65.22 2 14
Average= 3.43
(KJ/cycle)

Cycle 17 GMT 14/ 9/2023 0: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 19 15.23 440 127 0.13 / 57.43 2 4
2 3 1358.16 -1 15.51 1 0 0.00 / 57.43 2 4
3 3 1433.16 1 15.10 2320 35 0.16 / 57.47 2 13
4 7 2007.88 38 14.84 2923 1648 1.81 / 59.12 2 13
5 13 1385.76 18 14.98 2169 585 2.40 / 59.70 2 16
6 13 903.16 18 15.06 1554 421 2.82 / 60.12 2 18
7 13 461.36 18 15.16 970 265 3.08 / 60.39 2 19
8 13 123.44 18 15.26 481 132 3.21 / 60.52 2 15
9 8 0.20 165 15.26 293 738 3.95 / 61.26 2 17
Average= 3.40
(KJ/cycle)

Cycle 16 GMT 4/ 9/2023 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 20 15.24 443 135 0.14 / 53.53 2 4
2 3 1358.36 -1 15.51 0 0 0.00 / 53.53 2 4
3 7 2017.44 38 14.85 2927 1652 1.79 / 55.18 2 13
4 13 1490.96 18 14.94 2306 620 2.41 / 55.80 2 16
5 13 849.36 18 15.08 1491 405 2.81 / 56.20 2 19
6 13 420.64 18 15.17 912 249 3.06 / 56.45 2 19
7 13 98.72 18 15.28 445 122 3.18 / 56.57 2 13
8 8 0.44 165 15.27 291 733 3.92 / 57.31 2 20
Average= 3.37
(KJ/cycle)

Cycle 15 GMT 25/ 8/2023 10:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 23 15.24 421 148 0.15 / 49.51 2 4
2 3 1267.12 -4 15.51 0 0 0.00 / 49.51 2 4
3 7 2013.08 38 14.87 2922 1651 1.80 / 51.16 2 13
4 13 1597.20 18 14.93 2422 651 2.45 / 51.81 2 15
5 13 943.64 18 15.05 1607 435 2.88 / 52.25 2 19
6 13 504.76 18 15.15 1029 281 3.17 / 52.53 2 19
7 13 113.28 18 15.28 466 128 3.29 / 52.66 2 14
8 8 -0.08 165 15.26 292 735 4.03 / 53.39 2 15
Average= 3.34
(KJ/cycle)

Cycle 14 GMT 15/ 8/2023 16:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 30 15.25 424 194 0.19 / 45.51 2 4
2 3 994.36 -14 15.53 0 0 0.00 / 45.51 2 4
3 3 1461.08 2 15.11 2330 70 0.26 / 45.58 2 11
4 7 2005.68 38 14.87 2915 1647 1.91 / 47.23 2 12
5 13 1334.40 18 14.98 2095 565 2.48 / 47.80 2 16
6 13 877.40 18 15.07 1517 412 2.89 / 48.21 2 19
7 13 537.20 18 15.14 1074 293 3.18 / 48.50 2 19
8 13 126.24 18 15.27 483 133 3.31 / 48.63 2 15
9 8 -0.12 165 15.26 290 730 4.04 / 49.36 2 17
Average= 3.29
(KJ/cycle)

Cycle 13 GMT 5/ 8/2023 22: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 30 15.28 431 198 0.20 / 41.44 2 4
2 7 2007.76 38 14.87 2914 1647 1.84 / 43.08 2 12
3 13 1427.88 18 14.97 2225 600 2.44 / 43.68 2 16
4 13 906.16 18 15.06 1556 422 2.87 / 44.10 2 19
5 13 379.28 18 15.20 851 233 3.10 / 44.34 2 18
6 13 107.12 18 15.29 452 124 3.22 / 44.46 2 13
7 8 -0.08 165 15.28 288 726 3.95 / 45.19 2 17
8 14 -0.08 30 15.26 287 131 4.08 / 45.32 2 18
Average= 3.24
(KJ/cycle)

Cycle 12 GMT 27/ 7/2023 1:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 30 15.30 439 202 0.20 / 38.51 2 4
2 7 1456.52 38 15.06 2228 1275 1.48 / 39.79 2 15
3 13 866.92 18 15.18 1505 411 1.89 / 40.20 2 18
4 13 256.72 18 15.33 671 185 2.07 / 40.38 2 16
5 13 95.64 18 15.35 435 120 2.19 / 40.50 2 14
6 8 0.04 165 15.34 290 734 2.93 / 41.24 2 19
Average= 3.17
(KJ/cycle)

Cycle 11 GMT 17/ 7/2023 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 30 15.27 434 199 0.20 / 35.03 2 4
2 7 1411.32 75 14.99 2165 2434 2.63 / 37.46 2 16
3 13 79.04 18 15.37 415 115 2.75 / 37.58 2 13
4 8 0.44 165 15.34 291 737 3.48 / 38.31 2 19
Average= 3.19
(KJ/cycle)

Cycle 10 GMT 7/ 7/2023 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 30 15.24 436 199 0.20 / 31.08 2 4
2 3 1019.84 1 15.26 1759 27 0.23 / 31.10 2 14
3 7 1659.32 74 14.88 2471 2721 2.95 / 33.82 2 15
4 13 211.80 18 15.30 609 168 3.11 / 33.99 2 16
5 13 58.88 18 15.33 380 105 3.22 / 34.10 2 14
6 8 0.44 165 15.31 289 730 3.95 / 34.83 2 19
Average= 3.17
(KJ/cycle)

Cycle 9 GMT 27/ 6/2023 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 30 15.29 428 196 0.20 / 26.54 2 4
2 7 1999.56 74 14.77 2889 3158 3.35 / 29.69 2 13
3 13 561.08 18 15.17 1112 304 3.66 / 30.00 2 18
4 13 163.20 18 15.28 537 148 3.81 / 30.15 2 15
5 8 0.12 165 15.30 290 732 4.54 / 30.88 2 19
Average= 3.09
(KJ/cycle)

Cycle 8 GMT 17/ 6/2023 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 30 15.32 424 195 0.19 / 22.96 2 4
2 7 1513.00 74 14.96 2284 2528 2.72 / 25.49 2 15
3 13 112.32 18 15.34 460 127 2.85 / 25.61 2 14
4 8 -0.04 165 15.33 287 726 3.58 / 26.34 2 17
Average= 2.93
(KJ/cycle)

Cycle 7 GMT 7/ 6/2023 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 29 15.30 431 191 0.19 / 19.94 2 3
2 7 1100.08 75 15.09 1754 1985 2.18 / 21.93 2 16
3 13 45.60 18 15.37 365 101 2.28 / 22.03 2 15
4 8 0.24 165 15.36 291 738 3.01 / 22.76 2 17
Average= 2.85
(KJ/cycle)

Cycle 6 GMT 6/ 6/2023 8:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 29 15.29 417 185 0.18 / 16.78 2 3
2 7 1206.20 75 15.06 1889 2134 2.32 / 18.91 2 15
3 13 52.00 18 15.36 376 104 2.42 / 19.02 2 13
4 8 0.32 165 15.34 289 731 3.15 / 19.75 2 17
Average= 2.82
(KJ/cycle)

Cycle 5 GMT 5/ 6/2023 9: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 29 15.31 418 186 0.19 / 13.43 2 3
2 7 1349.92 74 15.02 2080 2312 2.50 / 15.75 2 14
3 13 96.56 18 15.35 439 121 2.62 / 15.87 2 14
4 8 0.28 165 15.33 288 728 3.35 / 16.60 2 17
Average= 2.77
(KJ/cycle)

Cycle 4 GMT 4/ 6/2023 9:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 29 15.33 433 192 0.19 / 10.21 2 4
2 7 1041.96 74 15.14 1682 1884 2.08 / 12.09 2 16
3 13 37.20 18 15.39 354 98 2.18 / 12.19 2 14
4 8 0.04 165 15.37 289 733 2.91 / 12.92 2 17
5 14 0.04 75 15.34 284 327 3.23 / 13.25 2 19
Average= 2.65
(KJ/cycle)

Cycle 3 GMT 3/ 6/2023 9:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 29 15.33 430 191 0.19 / 7.38 2 4
2 7 1056.64 74 15.13 1700 1903 2.09 / 9.28 2 16
3 8 0.36 165 15.36 288 730 2.82 / 10.01 2 18
Average= 2.50
(KJ/cycle)

Cycle 2 GMT 2/ 6/2023 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 33 15.28 417 210 0.21 / 4.61 2 3
2 3 873.32 -2 15.58 0 0 0.00 / 4.61 2 3
3 3 948.84 -1 15.61 0 0 0.00 / 4.61 2 3
4 7 1023.28 74 15.15 1654 1854 2.06 / 6.46 2 16
5 8 0.20 165 15.37 286 725 2.79 / 7.19 2 16
Average= 2.40
(KJ/cycle)

Cycle 1 GMT 1/ 6/2023 11:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 28 15.46 377 163 0.16 / 1.74 2 3
2 10 1002.72 2 15.27 1686 51 0.21 / 1.79 2 7
3 7 978.04 74 15.12 1595 1785 2.00 / 3.58 2 15
4 13 17.28 18 15.38 322 89 2.09 / 3.67 2 14
5 8 0.08 165 15.33 289 731 2.82 / 4.40 2 17
Average= 2.20
(KJ/cycle)

Cycle 0 GMT 1/ 6/2023 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.12 27 15.60 416 175 0.18 / 0.18 2 3
2 7 138.52 74 15.56 440 507 0.68 / 0.68 2 4
3 8 0.20 240 15.52 241 898 1.58 / 1.58 2 19
Average= 1.58
(KJ/cycle)