SIO Argo Site:
Pump Diagnostics Page   



Serial= 3194 WMO= 5906924

Return

←PreviousNext→

Cycle 60 GMT 8/11/2024 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 31 15.10 429 201 0.20 / 231.04 2 3
2 3 985.84 -1 15.46 0 0 0.00 / 231.04 2 3
3 3 1017.60 1 15.11 1745 26 0.23 / 231.06 2 8
4 7 2013.52 38 14.65 2983 1661 1.89 / 232.73 2 6
5 13 1707.76 18 14.72 2602 689 2.58 / 233.41 2 6
6 13 1068.36 18 14.86 1783 477 3.05 / 233.89 2 5
7 13 464.12 18 15.05 984 267 3.32 / 234.16 2 6
8 13 131.60 18 15.15 483 132 3.45 / 234.29 2 4
9 13 18.44 18 15.18 313 86 3.54 / 234.38 2 7
10 8 0.96 165 15.14 284 709 4.25 / 235.08 2 10
Average= 3.85
(KJ/cycle)

Cycle 59 GMT 30/10/2024 2:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 31 15.11 431 202 0.20 / 226.76 2 3
2 3 984.80 -1 15.45 0 0 0.00 / 226.76 2 3
3 7 2012.20 38 14.65 2985 1662 1.86 / 228.42 2 4
4 13 1649.04 18 14.73 2536 672 2.54 / 229.10 2 5
5 13 1122.12 18 14.85 1858 497 3.03 / 229.59 2 7
6 13 514.40 18 15.03 1049 284 3.32 / 229.88 2 6
7 13 170.28 18 15.15 547 149 3.47 / 230.03 2 6
8 13 26.00 18 15.18 330 90 3.56 / 230.12 2 12
9 8 1.08 165 15.14 289 722 4.28 / 230.84 2 6
Average= 3.85
(KJ/cycle)

Cycle 58 GMT 20/10/2024 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 31 15.11 429 201 0.20 / 222.73 2 3
2 7 2009.64 38 14.65 2987 1663 1.86 / 224.39 2 6
3 13 1519.16 18 14.76 2365 628 2.49 / 225.02 2 8
4 13 951.20 18 14.89 1644 441 2.93 / 225.46 2 6
5 13 429.48 18 15.07 919 249 3.18 / 225.71 2 6
6 13 144.88 18 15.16 502 137 3.32 / 225.84 2 4
7 8 0.28 165 15.15 286 715 4.03 / 226.56 2 17
Average= 3.84
(KJ/cycle)

Cycle 57 GMT 10/10/2024 12:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 31 15.12 437 205 0.20 / 218.54 2 3
2 7 2019.16 38 14.66 2989 1665 1.87 / 220.21 2 7
3 13 1555.96 18 14.76 2425 644 2.51 / 220.85 2 6
4 13 946.48 18 14.91 1634 439 2.95 / 221.29 2 7
5 13 511.16 18 15.05 1038 281 3.23 / 221.57 2 3
6 13 170.44 18 15.16 548 150 3.38 / 221.72 2 5
7 13 24.84 18 15.19 327 89 3.47 / 221.81 2 10
8 8 1.60 165 15.15 287 717 4.19 / 222.53 2 5
Average= 3.84
(KJ/cycle)

Cycle 56 GMT 30/ 9/2024 17:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 31 15.13 426 200 0.20 / 214.44 2 3
2 7 2009.60 38 14.66 2969 1654 1.85 / 216.10 2 5
3 13 1449.64 18 14.78 2272 604 2.46 / 216.70 2 6
4 13 1043.44 18 14.87 1753 469 2.93 / 217.17 2 7
5 13 588.60 18 15.00 1155 312 3.24 / 217.48 2 6
6 13 127.96 18 15.16 481 131 3.37 / 217.61 2 5
7 8 -0.08 165 15.16 289 723 4.09 / 218.34 2 11
Average= 3.83
(KJ/cycle)

Cycle 55 GMT 20/ 9/2024 22:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 31 15.14 455 214 0.21 / 210.23 2 3
2 7 2006.12 38 14.67 2971 1656 1.87 / 211.89 2 4
3 13 1602.24 18 14.77 2484 660 2.53 / 212.55 2 7
4 13 1116.36 18 14.86 1854 496 3.03 / 213.05 2 8
5 13 656.92 18 14.99 1243 335 3.36 / 213.38 2 6
6 13 144.44 18 15.17 503 137 3.50 / 213.52 2 4
7 8 0.96 165 15.16 289 723 4.22 / 214.24 2 6
Average= 3.83
(KJ/cycle)

Cycle 54 GMT 11/ 9/2024 3:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 31 15.14 428 201 0.20 / 206.15 2 3
2 7 2010.84 38 14.66 2975 1657 1.86 / 207.81 2 4
3 13 1516.76 18 14.77 2356 626 2.48 / 208.44 2 7
4 13 987.44 18 14.90 1669 448 2.93 / 208.88 2 6
5 13 595.28 18 15.01 1154 312 3.24 / 209.20 2 5
6 13 82.40 18 15.19 403 110 3.35 / 209.31 2 5
7 8 2.00 165 15.17 285 713 4.07 / 210.02 2 11
Average= 3.82
(KJ/cycle)

Cycle 53 GMT 1/ 9/2024 8:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 31 15.14 441 207 0.21 / 202.12 2 3
2 7 2004.24 38 14.67 2988 1666 1.87 / 203.78 2 3
3 13 1510.52 18 14.77 2358 627 2.50 / 204.41 2 7
4 13 895.72 18 14.93 1558 419 2.92 / 204.83 2 5
5 13 473.28 18 15.05 987 267 3.19 / 205.09 2 5
6 13 145.12 18 15.16 505 138 3.32 / 205.23 2 5
7 8 -2.12 165 15.16 288 720 4.04 / 205.95 2 14
Average= 3.81
(KJ/cycle)

Cycle 52 GMT 22/ 8/2024 13:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 31 15.15 441 207 0.21 / 198.02 2 3
2 7 2010.60 38 14.67 2985 1664 1.87 / 199.69 2 7
3 13 1511.48 18 14.79 2359 628 2.50 / 200.31 2 7
4 13 944.28 18 14.91 1625 436 2.94 / 200.75 2 7
5 13 581.76 18 15.02 1138 308 3.24 / 201.06 2 6
6 13 136.56 18 15.17 492 134 3.38 / 201.19 2 5
7 8 -0.88 165 15.17 286 716 4.09 / 201.91 2 6
Average= 3.81
(KJ/cycle)

Cycle 51 GMT 12/ 8/2024 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 15.13 435 204 0.20 / 193.91 2 3
2 7 2003.16 38 14.67 2978 1660 1.86 / 195.57 2 5
3 13 1684.16 18 14.74 2578 684 2.55 / 196.25 2 6
4 13 969.16 18 14.92 1647 442 2.99 / 196.69 2 7
5 13 486.44 18 15.06 1013 275 3.27 / 196.97 2 7
6 13 101.80 18 15.18 442 121 3.39 / 197.09 2 5
7 8 -1.40 165 15.18 290 726 4.11 / 197.82 2 13
Average= 3.80
(KJ/cycle)

Cycle 50 GMT 2/ 8/2024 23:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 31 15.16 467 219 0.22 / 189.80 2 2
2 7 2004.00 38 14.68 2971 1657 1.88 / 191.46 2 7
3 13 1638.08 18 14.77 2517 669 2.55 / 192.12 2 6
4 13 930.52 18 14.94 1607 432 2.98 / 192.56 2 7
5 13 548.32 18 15.05 1092 296 3.27 / 192.85 2 5
6 13 134.84 18 15.18 491 134 3.41 / 192.99 2 5
7 8 -0.60 165 15.18 286 716 4.12 / 193.70 2 19
Average= 3.80
(KJ/cycle)

Cycle 49 GMT 24/ 7/2024 4:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 31 15.15 439 206 0.21 / 185.65 2 2
2 7 2011.44 38 14.68 2988 1667 1.87 / 187.31 2 6
3 13 1577.56 18 14.78 2455 653 2.53 / 187.97 2 6
4 13 1075.64 18 14.88 1797 481 3.01 / 188.45 2 5
5 13 471.20 18 15.08 986 268 3.28 / 188.71 2 7
6 13 128.68 18 15.19 486 133 3.41 / 188.85 2 4
7 8 0.60 165 15.18 292 731 4.14 / 189.58 2 12
Average= 3.79
(KJ/cycle)

Cycle 48 GMT 14/ 7/2024 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 31 15.15 433 203 0.20 / 181.50 2 3
2 7 2013.08 38 14.71 2994 1674 1.88 / 183.18 2 8
3 13 1596.76 18 14.79 2472 658 2.54 / 183.83 2 6
4 13 1050.24 18 14.90 1770 475 3.01 / 184.31 2 7
5 13 452.00 18 15.10 954 259 3.27 / 184.57 2 7
6 13 168.84 18 15.18 537 147 3.42 / 184.72 2 7
7 8 0.88 165 15.19 289 724 4.14 / 185.44 2 5
Average= 3.78
(KJ/cycle)

Cycle 47 GMT 4/ 7/2024 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 31 15.16 442 208 0.21 / 177.49 2 4
2 7 2006.16 38 14.69 2987 1667 1.88 / 179.16 2 6
3 13 1482.56 18 14.81 2328 621 2.50 / 179.78 2 7
4 13 997.92 18 14.92 1705 458 2.95 / 180.24 2 7
5 13 356.04 18 15.13 820 223 3.18 / 180.46 2 8
6 13 97.20 18 15.21 428 117 3.29 / 180.58 2 6
7 8 1.48 165 15.19 287 719 4.01 / 181.30 2 14
Average= 3.78
(KJ/cycle)

Cycle 46 GMT 24/ 6/2024 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 31 15.15 432 203 0.20 / 173.36 2 3
2 7 2012.04 38 14.70 2988 1669 1.87 / 175.03 2 7
3 13 1534.04 18 14.80 2397 639 2.51 / 175.67 2 5
4 13 1037.36 18 14.91 1760 472 2.98 / 176.14 2 5
5 13 535.80 18 15.07 1075 292 3.27 / 176.43 2 4
6 13 126.56 18 15.20 477 131 3.41 / 176.56 2 3
7 8 0.56 165 15.20 288 722 4.13 / 177.29 2 8
Average= 3.77
(KJ/cycle)

Cycle 45 GMT 15/ 6/2024 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 31 15.16 458 215 0.22 / 169.24 2 3
2 7 2007.44 39 14.69 2999 1718 1.93 / 170.96 2 5
3 13 1445.00 18 14.82 2279 608 2.54 / 171.56 2 7
4 13 1019.76 18 14.92 1727 464 3.01 / 172.03 2 5
5 13 471.20 18 15.10 988 269 3.27 / 172.30 2 4
6 13 131.72 18 15.20 492 135 3.41 / 172.43 2 6
7 8 -2.40 165 15.20 290 727 4.14 / 173.16 2 7
Average= 3.76
(KJ/cycle)

Cycle 44 GMT 5/ 6/2024 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 31 15.15 438 206 0.21 / 165.13 2 3
2 7 2012.80 38 14.70 2987 1669 1.87 / 166.80 2 4
3 13 1633.52 18 14.77 2526 672 2.55 / 167.47 2 5
4 13 946.80 18 14.95 1637 441 2.99 / 167.91 2 8
5 13 406.20 18 15.11 893 243 3.23 / 168.15 2 6
6 13 133.84 18 15.20 495 135 3.36 / 168.29 2 6
7 8 -1.36 165 15.19 294 737 4.10 / 169.02 2 16
Average= 3.76
(KJ/cycle)

Cycle 43 GMT 26/ 5/2024 10:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.08 30 15.19 463 211 0.21 / 161.01 2 3
2 3 1017.56 1 15.16 1780 27 0.24 / 161.03 2 6
3 7 2007.64 38 14.69 2982 1665 1.90 / 162.70 2 6
4 13 1544.20 18 14.80 2407 641 2.54 / 163.34 2 7
5 13 956.52 18 14.93 1647 443 2.99 / 163.78 2 9
6 13 521.16 18 15.06 1056 286 3.27 / 164.07 2 6
7 13 124.96 18 15.19 479 131 3.40 / 164.20 2 4
8 8 -0.60 165 15.19 288 722 4.13 / 164.92 2 3
Average= 3.75
(KJ/cycle)

Cycle 42 GMT 16/ 5/2024 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 15.19 444 202 0.20 / 157.39 2 3
2 7 1432.16 38 14.92 2252 1277 1.48 / 158.67 2 7
3 13 1387.88 18 14.91 2193 589 2.07 / 159.26 2 5
4 13 889.64 18 15.03 1556 421 2.49 / 159.68 2 5
5 13 443.24 18 15.14 956 261 2.75 / 159.94 2 6
6 13 92.12 18 15.25 433 119 2.87 / 160.06 2 4
7 8 0.32 165 15.24 293 737 3.60 / 160.80 2 5
Average= 3.74
(KJ/cycle)

Cycle 41 GMT 6/ 5/2024 19: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 15.23 425 201 0.20 / 153.87 2 3
2 3 978.36 -1 15.54 0 0 0.00 / 153.87 2 3
3 7 1385.36 38 14.93 2183 1239 1.44 / 155.11 2 7
4 13 1345.64 18 14.94 2139 575 2.01 / 155.68 2 4
5 13 958.92 18 15.00 1643 444 2.46 / 156.13 2 8
6 13 312.64 18 15.20 760 208 2.67 / 156.33 2 6
7 13 96.96 18 15.25 438 120 2.79 / 156.45 2 8
8 8 0.32 165 15.23 293 736 3.52 / 157.19 3 17
Average= 3.74
(KJ/cycle)

Cycle 40 GMT 26/ 4/2024 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 15.19 435 205 0.20 / 150.71 2 3
2 3 986.52 -1 15.53 0 0 0.00 / 150.71 2 3
3 7 1073.92 39 15.09 1774 1044 1.25 / 151.75 2 7
4 13 1041.24 18 15.07 1748 474 1.72 / 152.23 2 6
5 13 945.16 18 15.06 1616 438 2.16 / 152.66 2 8
6 13 264.24 18 15.26 675 185 2.35 / 152.85 2 5
7 13 61.44 18 15.30 377 104 2.45 / 152.95 2 4
8 8 0.52 165 15.27 284 716 3.17 / 153.67 2 7
Average= 3.75
(KJ/cycle)

Cycle 39 GMT 17/ 4/2024 2:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 31 15.17 437 206 0.21 / 146.98 2 3
2 7 1571.84 38 14.87 2432 1374 1.58 / 148.36 2 6
3 13 1476.48 18 14.89 2317 621 2.20 / 148.98 2 7
4 13 916.76 18 15.02 1596 431 2.63 / 149.41 2 9
5 13 432.48 18 15.16 928 253 2.89 / 149.66 2 7
6 13 86.40 18 15.25 419 115 3.00 / 149.78 2 5
7 8 -0.04 165 15.23 288 724 3.72 / 150.50 2 17
Average= 3.76
(KJ/cycle)

Cycle 38 GMT 7/ 4/2024 5:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 31 15.18 446 210 0.21 / 142.78 2 3
2 7 2008.24 38 14.72 2989 1672 1.88 / 144.45 2 7
3 13 1490.96 18 14.83 2335 623 2.51 / 145.07 2 8
4 13 1056.92 18 14.92 1780 478 2.98 / 145.55 2 7
5 13 453.60 18 15.11 965 262 3.25 / 145.81 2 7
6 13 119.12 18 15.22 481 132 3.38 / 145.95 2 5
7 13 30.72 18 15.23 350 96 3.47 / 146.04 2 11
8 8 -1.04 165 15.20 294 737 4.21 / 146.78 2 13
Average= 3.76
(KJ/cycle)

Cycle 37 GMT 28/ 3/2024 10:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 31 15.18 450 212 0.21 / 138.67 2 3
2 7 2011.68 38 14.72 2988 1671 1.88 / 140.34 2 7
3 13 1528.60 18 14.84 2396 640 2.52 / 140.98 2 6
4 13 1050.32 18 14.93 1770 476 3.00 / 141.45 2 5
5 13 463.04 18 15.11 978 266 3.26 / 141.72 2 7
6 13 127.16 18 15.22 474 130 3.39 / 141.85 2 4
7 8 -0.92 165 15.22 286 718 4.11 / 142.57 2 16
Average= 3.75
(KJ/cycle)

Cycle 36 GMT 18/ 3/2024 15:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 31 15.21 426 201 0.20 / 134.54 2 2
2 7 1897.16 38 14.73 2843 1591 1.79 / 136.14 2 6
3 13 1500.96 18 14.83 2354 628 2.42 / 136.76 2 7
4 13 1036.28 18 14.92 1747 469 2.89 / 137.23 2 7
5 13 526.56 18 15.08 1064 289 3.18 / 137.52 2 7
6 13 131.20 18 15.21 484 133 3.31 / 137.65 2 4
7 13 17.24 18 15.24 319 88 3.40 / 137.74 2 4
8 8 -2.00 165 15.21 284 713 4.11 / 138.46 3 4
Average= 3.74
(KJ/cycle)

Cycle 35 GMT 8/ 3/2024 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 31 15.17 433 204 0.20 / 130.88 2 3
2 7 1529.44 38 14.90 2377 1346 1.55 / 132.23 2 7
3 13 1486.72 18 14.89 2328 624 2.17 / 132.85 2 7
4 13 919.44 18 15.04 1594 432 2.60 / 133.28 2 6
5 13 365.24 18 15.19 830 227 2.83 / 133.51 2 3
6 13 87.88 18 15.27 421 116 2.95 / 133.63 2 4
7 8 -0.08 165 15.25 285 717 3.66 / 134.34 2 8
Average= 3.73
(KJ/cycle)

Cycle 34 GMT 27/ 2/2024 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 31 15.21 425 200 0.20 / 126.61 2 3
2 7 2003.88 38 14.74 2977 1667 1.87 / 128.27 2 6
3 13 1597.08 18 14.83 2478 661 2.53 / 128.93 2 8
4 13 1092.96 18 14.94 1819 489 3.02 / 129.42 2 6
5 13 584.68 18 15.08 1144 311 3.33 / 129.73 2 6
6 13 132.60 18 15.24 481 132 3.46 / 129.87 2 5
7 13 19.76 18 15.25 319 88 3.55 / 129.95 2 3
8 8 1.08 165 15.22 289 726 4.27 / 130.68 2 6
Average= 3.73
(KJ/cycle)

Cycle 33 GMT 18/ 2/2024 2: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 31 15.23 433 204 0.20 / 122.76 2 3
2 7 1649.16 38 14.85 2523 1424 1.63 / 124.19 2 8
3 13 1457.96 18 14.89 2293 615 2.24 / 124.80 2 7
4 13 910.36 18 15.01 1586 429 2.67 / 125.23 2 6
5 13 375.00 18 15.18 840 230 2.90 / 125.46 2 7
6 13 55.36 18 15.27 370 102 3.00 / 125.56 2 8
7 8 1.12 165 15.24 284 714 3.72 / 126.28 2 4
8 14 1.12 30 15.21 282 129 3.85 / 126.40 3 7
Average= 3.72
(KJ/cycle)

Cycle 32 GMT 8/ 2/2024 4:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 31 15.21 429 202 0.20 / 119.34 2 3
2 7 1346.28 38 14.99 2139 1218 1.42 / 120.56 2 4
3 13 1305.92 18 14.98 2089 563 1.98 / 121.12 2 7
4 13 834.40 18 15.09 1477 401 2.39 / 121.52 2 6
5 13 338.20 18 15.23 785 215 2.60 / 121.73 2 6
6 13 67.40 18 15.29 387 107 2.71 / 121.84 2 6
7 8 0.40 165 15.27 285 718 3.42 / 122.56 2 15
Average= 3.71
(KJ/cycle)

Cycle 31 GMT 29/ 1/2024 8:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 31 15.22 440 208 0.21 / 115.59 2 3
2 7 1661.60 38 14.86 2536 1432 1.64 / 117.02 2 8
3 13 1517.00 18 14.90 2373 636 2.28 / 117.66 2 6
4 13 886.68 18 15.05 1551 420 2.70 / 118.08 2 6
5 13 354.20 18 15.20 804 220 2.92 / 118.30 2 5
6 13 81.32 18 15.28 405 111 3.03 / 118.41 2 4
7 8 0.68 165 15.25 287 722 3.75 / 119.13 2 15
Average= 3.72
(KJ/cycle)

Cycle 30 GMT 19/ 1/2024 11: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 15.20 433 204 0.20 / 111.91 2 3
2 7 1514.88 38 14.94 2353 1336 1.54 / 113.25 2 7
3 13 1471.44 18 14.93 2312 621 2.16 / 113.87 2 5
4 13 899.60 18 15.06 1561 423 2.58 / 114.29 2 6
5 13 422.80 18 15.20 906 248 2.83 / 114.54 2 4
6 13 92.48 18 15.29 424 117 2.95 / 114.66 2 5
7 8 0.40 165 15.26 289 728 3.68 / 115.38 2 7
Average= 3.72
(KJ/cycle)

Cycle 29 GMT 9/ 1/2024 14:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 31 15.19 431 203 0.20 / 107.90 2 3
2 7 2004.72 38 14.74 2970 1664 1.87 / 109.57 2 3
3 13 1487.16 18 14.85 2335 624 2.49 / 110.19 2 6
4 13 998.76 18 14.97 1693 456 2.95 / 110.65 2 5
5 13 402.56 18 15.16 880 240 3.19 / 110.89 2 5
6 13 84.72 18 15.25 411 113 3.30 / 111.00 2 4
7 8 -0.28 165 15.24 281 707 4.01 / 111.71 2 14
Average= 3.72
(KJ/cycle)

Cycle 28 GMT 30/12/2023 18:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 31 15.21 419 198 0.20 / 103.80 2 2
2 7 2009.56 38 14.76 2998 1682 1.88 / 105.48 2 4
3 13 1500.36 18 14.87 2350 629 2.51 / 106.11 2 5
4 13 1064.52 18 14.95 1787 481 2.99 / 106.59 2 5
5 13 512.24 18 15.13 1042 284 3.27 / 106.87 2 6
6 13 119.36 18 15.24 461 126 3.40 / 107.00 2 4
7 8 -0.60 165 15.24 279 702 4.10 / 107.70 2 9
Average= 3.71
(KJ/cycle)

Cycle 27 GMT 20/12/2023 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 15.22 423 193 0.19 / 99.73 2 3
2 7 2010.76 39 14.76 2987 1719 1.91 / 101.45 2 6
3 13 1439.44 18 14.89 2273 609 2.52 / 102.06 2 4
4 13 1004.60 18 14.98 1709 461 2.98 / 102.52 2 6
5 13 401.08 18 15.18 882 241 3.22 / 102.76 2 5
6 13 127.40 18 15.26 469 129 3.35 / 102.89 2 4
7 8 2.04 165 15.25 284 715 4.07 / 103.60 2 17
Average= 3.70
(KJ/cycle)

Cycle 26 GMT 11/12/2023 4:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 15.22 436 199 0.20 / 95.65 2 3
2 7 2005.64 38 14.76 2991 1678 1.88 / 97.33 2 5
3 13 1575.68 18 14.86 2454 656 2.53 / 97.99 2 5
4 13 1026.72 18 14.98 1741 469 3.00 / 98.46 2 6
5 13 379.84 18 15.18 861 235 3.24 / 98.69 2 7
6 13 109.04 18 15.27 448 123 3.36 / 98.81 2 3
7 8 -0.44 165 15.26 286 720 4.08 / 99.53 2 16
Average= 3.69
(KJ/cycle)

Cycle 25 GMT 1/12/2023 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 30 15.23 459 210 0.21 / 91.54 2 2
2 7 2009.56 38 14.76 2987 1675 1.89 / 93.22 2 4
3 13 1550.96 18 14.86 2427 649 2.53 / 93.87 2 4
4 13 1051.96 18 14.97 1778 479 3.01 / 94.35 2 5
5 13 442.36 18 15.17 941 257 3.27 / 94.60 2 3
6 13 109.96 18 15.26 458 126 3.40 / 94.73 2 6
7 8 -1.04 165 15.25 288 725 4.12 / 95.45 2 6
Average= 3.67
(KJ/cycle)

Cycle 24 GMT 21/11/2023 14:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 30 15.25 427 195 0.20 / 87.42 2 3
2 7 2004.36 38 14.77 2990 1678 1.87 / 89.10 2 4
3 13 1566.48 18 14.87 2440 653 2.53 / 89.75 2 4
4 13 1053.12 18 14.99 1772 478 3.00 / 90.23 2 4
5 13 444.84 18 15.17 947 259 3.26 / 90.49 2 4
6 13 66.52 18 15.28 397 109 3.37 / 90.60 2 3
7 8 0.00 165 15.27 291 733 4.11 / 91.33 2 2
Average= 3.65
(KJ/cycle)

Cycle 23 GMT 11/11/2023 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 15.22 436 199 0.20 / 83.86 2 2
2 7 1442.00 39 14.98 2267 1324 1.52 / 85.18 2 3
3 13 1402.12 18 14.97 2219 598 2.12 / 85.78 2 4
4 13 858.08 18 15.09 1516 412 2.53 / 86.19 2 5
5 13 268.20 18 15.26 694 191 2.72 / 86.38 2 5
6 13 52.76 18 15.32 374 103 2.83 / 86.49 2 2
7 8 -1.72 165 15.29 293 739 3.57 / 87.23 2 14
Average= 3.63
(KJ/cycle)

Cycle 22 GMT 1/11/2023 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 30 15.23 433 198 0.20 / 79.76 2 3
2 7 2008.72 38 14.77 2988 1677 1.87 / 81.44 2 4
3 13 1665.52 18 14.85 2561 685 2.56 / 82.12 2 4
4 13 943.76 18 15.00 1625 439 3.00 / 82.56 2 5
5 13 444.20 18 15.16 956 261 3.26 / 82.82 2 6
6 13 63.28 18 15.29 388 107 3.37 / 82.93 2 3
7 8 -0.32 165 15.26 291 733 4.10 / 83.66 2 9
Average= 3.64
(KJ/cycle)

Cycle 21 GMT 23/10/2023 4: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.04 30 15.26 461 211 0.21 / 75.74 2 3
2 7 2003.52 38 14.76 2997 1681 1.89 / 77.42 2 4
3 13 1472.20 18 14.89 2318 621 2.51 / 78.04 2 4
4 13 981.28 18 14.99 1679 453 2.97 / 78.49 2 5
5 13 387.12 18 15.19 863 236 3.20 / 78.73 2 5
6 13 70.16 18 15.28 394 108 3.31 / 78.84 2 4
7 8 0.40 165 15.26 287 723 4.03 / 79.56 2 14
Average= 3.62
(KJ/cycle)

Cycle 20 GMT 13/10/2023 8:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 30 15.28 455 209 0.21 / 72.18 2 3
2 7 1387.96 38 15.02 2196 1253 1.46 / 73.43 2 4
3 13 1346.84 18 15.00 2145 579 2.04 / 74.01 2 4
4 13 920.16 18 15.09 1590 432 2.47 / 74.44 2 5
5 13 361.04 18 15.24 836 229 2.70 / 74.67 2 5
6 13 80.04 18 15.32 412 114 2.82 / 74.79 2 3
7 8 -0.28 165 15.30 294 742 3.56 / 75.53 2 4
Average= 3.60
(KJ/cycle)

Cycle 19 GMT 3/10/2023 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 15.27 429 197 0.20 / 68.80 2 2
2 3 988.88 -1 15.59 0 0 0.00 / 68.80 2 2
3 7 1342.00 38 15.05 2138 1223 1.42 / 70.03 2 4
4 13 1299.44 18 15.05 2089 566 1.99 / 70.59 2 4
5 13 810.64 18 15.14 1453 396 2.38 / 70.99 2 5
6 13 417.44 18 15.24 906 249 2.63 / 71.24 2 5
7 8 -2.00 165 15.31 290 733 3.36 / 71.97 2 3
Average= 3.60
(KJ/cycle)

Cycle 18 GMT 23/ 9/2023 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 30 15.24 428 196 0.20 / 65.17 2 3
2 7 1564.04 38 14.94 2413 1370 1.57 / 66.54 2 5
3 13 1520.16 18 14.94 2360 635 2.20 / 67.18 2 4
4 13 852.44 18 15.10 1498 407 2.61 / 67.59 2 5
5 13 316.32 18 15.26 745 205 2.81 / 67.79 2 5
6 13 48.12 18 15.33 354 98 2.91 / 67.89 2 3
7 8 2.76 165 15.30 285 719 3.63 / 68.61 2 16
Average= 3.61
(KJ/cycle)

Cycle 17 GMT 13/ 9/2023 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 30 15.23 461 211 0.21 / 61.13 2 3
2 7 2009.04 38 14.79 2973 1671 1.88 / 62.80 2 4
3 13 1481.84 18 14.90 2336 627 2.51 / 63.43 2 4
4 13 981.80 18 15.02 1678 454 2.96 / 63.88 2 5
5 13 423.40 18 15.18 916 250 3.21 / 64.13 2 5
6 13 85.40 18 15.28 415 114 3.33 / 64.24 2 6
7 8 0.68 165 15.26 292 735 4.06 / 64.98 2 16
Average= 3.61
(KJ/cycle)

Cycle 16 GMT 3/ 9/2023 23:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 30 15.25 451 206 0.21 / 57.06 2 2
2 7 2009.92 38 14.79 2973 1671 1.88 / 58.73 2 3
3 13 1412.04 18 14.92 2235 600 2.48 / 59.33 2 4
4 13 1021.72 18 15.00 1727 466 2.94 / 59.80 2 4
5 13 510.64 18 15.15 1032 281 3.23 / 60.08 2 4
6 13 63.04 18 15.29 382 105 3.33 / 60.19 2 5
7 8 -0.52 165 15.27 290 731 4.06 / 60.92 2 8
Average= 3.58
(KJ/cycle)

Cycle 15 GMT 25/ 8/2023 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 15.23 433 198 0.20 / 53.58 2 2
2 7 1761.20 38 14.89 2672 1512 1.71 / 55.09 2 4
3 13 1203.56 18 15.02 1970 533 2.24 / 55.62 2 5
4 13 660.84 18 15.17 1238 338 2.58 / 55.96 2 5
5 13 210.28 18 15.29 604 166 2.75 / 56.13 2 5
6 8 1.56 165 15.31 289 730 3.48 / 56.86 2 6
Average= 3.55
(KJ/cycle)

Cycle 14 GMT 15/ 8/2023 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 30 15.25 431 197 0.20 / 49.57 2 2
2 7 2004.00 38 14.80 2969 1670 1.87 / 51.24 2 3
3 13 1442.44 18 14.91 2288 614 2.48 / 51.85 2 4
4 13 969.48 18 15.00 1664 449 2.93 / 52.30 2 4
5 13 370.68 18 15.20 828 227 3.16 / 52.53 2 4
6 13 92.80 18 15.28 433 119 3.28 / 52.65 2 3
7 8 0.08 165 15.26 291 733 4.01 / 53.38 2 6
Average= 3.56
(KJ/cycle)

Cycle 13 GMT 5/ 8/2023 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 30 15.24 461 211 0.21 / 45.48 2 2
2 3 1024.56 1 15.22 1781 27 0.24 / 45.51 2 2
3 7 2003.60 38 14.81 2975 1674 1.91 / 47.19 2 3
4 13 1509.04 18 14.91 2362 634 2.55 / 47.82 2 3
5 13 956.28 18 15.03 1654 447 2.99 / 48.27 2 3
6 13 451.40 18 15.19 958 262 3.26 / 48.53 2 4
7 13 108.00 18 15.29 442 122 3.38 / 48.65 2 3
8 8 0.00 165 15.28 286 721 4.10 / 49.37 2 4
Average= 3.53
(KJ/cycle)

Cycle 12 GMT 26/ 7/2023 16:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 29 15.23 430 190 0.19 / 41.32 2 2
2 3 1029.76 1 15.22 1763 27 0.22 / 41.34 2 3
3 7 2003.24 38 14.80 2963 1666 1.88 / 43.01 2 3
4 13 1513.84 18 14.92 2346 630 2.51 / 43.64 2 3
5 13 1008.12 18 15.03 1702 460 2.97 / 44.10 2 4
6 13 395.96 18 15.21 873 239 3.21 / 44.34 2 4
7 13 84.60 18 15.30 417 115 3.33 / 44.45 2 3
8 13 14.64 18 15.32 317 87 3.41 / 44.54 2 4
9 8 1.08 165 15.28 290 731 4.15 / 45.27 2 5
Average= 3.48
(KJ/cycle)

Cycle 11 GMT 16/ 7/2023 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 29 15.30 424 188 0.19 / 36.72 2 2
2 7 2010.96 74 14.66 2980 3233 3.42 / 39.95 2 3
3 13 554.92 18 15.13 1102 300 3.72 / 40.25 2 4
4 13 158.28 18 15.26 516 142 3.86 / 40.39 2 4
5 8 0.00 165 15.26 291 733 4.60 / 41.13 2 7
Average= 3.43
(KJ/cycle)

Cycle 10 GMT 6/ 7/2023 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 29 15.31 429 190 0.19 / 33.21 2 2
2 7 1429.20 74 14.93 2234 2468 2.66 / 35.68 2 4
3 13 95.88 18 15.36 429 119 2.78 / 35.80 2 4
4 8 1.40 165 15.34 290 734 3.51 / 36.53 2 6
Average= 3.32
(KJ/cycle)

Cycle 9 GMT 26/ 6/2023 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 28 15.33 426 183 0.18 / 29.92 2 2
2 3 1016.56 1 15.26 1785 27 0.21 / 29.95 2 3
3 7 1243.36 75 15.03 1997 2251 2.46 / 32.20 2 4
4 13 16.28 18 15.40 318 88 2.55 / 32.29 2 4
5 8 1.36 165 15.35 290 734 3.28 / 33.02 2 7
Average= 3.30
(KJ/cycle)

Cycle 8 GMT 17/ 6/2023 0:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 30 15.27 420 192 0.19 / 26.85 2 2
2 3 962.28 -1 15.61 0 0 0.00 / 26.85 2 2
3 7 1124.64 74 15.08 1834 2047 2.24 / 28.90 2 4
4 13 39.00 18 15.40 352 98 2.34 / 29.00 2 4
5 8 -0.12 165 15.37 291 738 3.07 / 29.74 2 7
Average= 3.30
(KJ/cycle)

Cycle 7 GMT 7/ 6/2023 2:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 15.25 419 185 0.19 / 23.33 2 2
2 7 1422.08 75 14.92 2219 2483 2.67 / 25.81 2 3
3 13 133.48 18 15.33 483 133 2.80 / 25.94 2 4
4 8 0.96 165 15.31 284 717 3.52 / 26.66 2 9
Average= 3.33
(KJ/cycle)

Cycle 6 GMT 6/ 6/2023 2:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 28 15.26 430 184 0.18 / 19.34 2 2
2 3 1016.40 1 15.25 1778 27 0.21 / 19.37 2 3
3 7 1627.80 74 14.83 2475 2716 2.93 / 22.08 2 3
4 13 373.20 18 15.22 830 227 3.15 / 22.31 2 4
5 13 96.24 18 15.30 425 117 3.27 / 22.43 2 3
6 8 0.64 165 15.28 283 713 3.98 / 23.14 2 9
Average= 3.31
(KJ/cycle)

Cycle 5 GMT 5/ 6/2023 1:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 15.24 423 181 0.18 / 15.44 2 2
2 7 1567.96 75 14.86 2407 2683 2.86 / 18.12 2 3
3 13 319.60 18 15.25 761 209 3.07 / 18.33 2 4
4 13 92.08 18 15.32 423 117 3.19 / 18.44 2 4
5 8 -2.40 165 15.29 283 714 3.90 / 19.16 2 6
Average= 3.19
(KJ/cycle)

Cycle 4 GMT 4/ 6/2023 1:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 28 15.26 408 174 0.17 / 11.36 2 2
2 3 1023.60 1 15.26 1779 27 0.20 / 11.39 2 3
3 7 1716.16 74 14.81 2582 2830 3.03 / 14.22 2 3
4 13 362.64 18 15.23 799 219 3.25 / 14.44 2 4
5 13 92.76 18 15.30 413 114 3.36 / 14.55 2 3
6 8 2.60 165 15.28 279 703 4.07 / 15.26 2 7
Average= 3.05
(KJ/cycle)

Cycle 3 GMT 3/ 6/2023 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 26 15.30 408 162 0.16 / 7.59 2 2
2 10 1033.76 2 15.23 1770 54 0.22 / 7.64 2 2
3 7 1514.96 74 14.90 2325 2564 2.78 / 10.20 2 3
4 13 303.76 18 15.27 716 197 2.98 / 10.40 2 4
5 13 87.84 18 15.32 394 109 3.09 / 10.51 2 3
6 8 2.48 165 15.30 269 679 3.76 / 11.19 2 8
Average= 2.80
(KJ/cycle)

Cycle 2 GMT 2/ 6/2023 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 33 15.28 405 204 0.20 / 4.49 2 2
2 3 828.84 -3 15.62 0 0 0.00 / 4.49 2 2
3 3 915.56 -2 15.62 0 0 0.00 / 4.49 2 2
4 7 1219.44 74 15.01 1939 2154 2.36 / 6.64 2 4
5 13 70.16 18 15.36 375 104 2.46 / 6.75 2 4
6 8 -1.92 165 15.34 268 678 3.14 / 7.42 2 9
Average= 2.47
(KJ/cycle)

Cycle 1 GMT 1/ 6/2023 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 28 15.44 381 165 0.16 / 1.77 2 2
2 7 997.48 74 15.06 1641 1829 1.99 / 3.60 2 4
3 8 -0.04 165 15.33 269 680 2.67 / 4.28 2 7
Average= 2.14
(KJ/cycle)

Cycle 0 GMT 31/ 5/2023 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.52 27 15.58 473 199 0.20 / 0.20 2 2
2 7 173.96 74 15.54 479 551 0.75 / 0.75 2 3
3 8 0.20 240 15.51 231 860 1.61 / 1.61 2 9
Average= 1.61
(KJ/cycle)