SIO Argo Site:
Pump Diagnostics Page   



Serial= 3191 WMO= 5906921

Return

←PreviousNext→

Cycle 61 GMT 17/11/2024 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 32 15.13 457 221 0.22 / 227.71 2 5
2 7 2007.48 38 14.82 3004 1692 1.91 / 229.40 2 17
3 13 1492.56 18 14.90 2360 633 2.55 / 230.03 2 19
4 13 961.48 18 15.01 1677 453 3.00 / 230.49 2 20
5 13 407.04 18 15.14 900 245 3.24 / 230.73 2 20
6 13 70.36 18 15.21 406 111 3.36 / 230.84 2 15
7 8 -0.04 165 15.18 298 746 4.10 / 231.59 2 22
Average= 3.74
(KJ/cycle)

Cycle 60 GMT 7/11/2024 22: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 32 15.14 463 224 0.22 / 223.58 2 5
2 7 2003.52 38 14.83 3006 1694 1.92 / 225.27 2 15
3 13 1521.72 18 14.90 2415 648 2.57 / 225.92 2 16
4 13 985.88 18 15.00 1709 461 3.03 / 226.38 2 19
5 13 446.76 18 15.14 956 261 3.29 / 226.64 2 20
6 13 28.60 18 15.22 348 95 3.38 / 226.74 2 12
7 8 0.04 165 15.19 300 752 4.14 / 227.49 2 25
Average= 3.73
(KJ/cycle)

Cycle 59 GMT 29/10/2024 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 32 15.15 460 223 0.22 / 219.39 2 7
2 7 2005.92 39 14.84 3009 1741 1.96 / 221.13 2 15
3 13 1479.76 18 14.92 2366 635 2.60 / 221.77 2 18
4 13 1032.16 18 14.99 1772 478 3.08 / 222.25 2 21
5 13 427.96 18 15.15 935 255 3.33 / 222.50 2 20
6 13 45.48 18 15.22 366 100 3.43 / 222.60 2 13
7 8 0.16 165 15.19 299 749 4.18 / 223.35 2 22
Average= 3.72
(KJ/cycle)

Cycle 58 GMT 19/10/2024 8:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 32 15.15 465 225 0.23 / 215.27 2 6
2 7 2014.44 38 14.82 3014 1697 1.92 / 216.97 2 15
3 13 1538.12 18 14.91 2431 652 2.58 / 217.62 2 17
4 13 954.04 18 15.02 1662 449 3.02 / 218.07 2 20
5 13 411.04 18 15.16 903 246 3.27 / 218.32 2 19
6 13 45.04 18 15.22 372 102 3.37 / 218.42 2 14
7 8 0.00 165 15.20 300 752 4.13 / 219.17 2 20
Average= 3.71
(KJ/cycle)

Cycle 57 GMT 9/10/2024 13:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 32 15.15 470 228 0.23 / 211.14 2 5
2 7 2004.04 38 14.84 3003 1693 1.92 / 212.84 2 16
3 13 1535.48 18 14.91 2441 655 2.58 / 213.49 2 17
4 13 943.88 18 15.03 1654 447 3.02 / 213.94 2 21
5 13 393.68 18 15.15 888 242 3.27 / 214.18 2 19
6 13 31.00 18 15.23 357 98 3.36 / 214.28 2 16
7 8 0.16 165 15.20 306 767 4.13 / 215.05 2 24
Average= 3.71
(KJ/cycle)

Cycle 56 GMT 29/ 9/2024 18:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 32 15.16 463 225 0.22 / 206.97 2 6
2 7 2007.08 38 14.85 3001 1693 1.92 / 208.67 2 15
3 13 1539.92 18 14.93 2432 654 2.57 / 209.32 2 17
4 13 1055.64 18 15.00 1808 488 3.06 / 209.81 2 23
5 13 403.84 18 15.16 900 246 3.31 / 210.05 2 19
6 13 18.04 18 15.23 335 92 3.40 / 210.15 2 15
7 8 0.16 165 15.21 306 768 4.17 / 210.91 2 24
Average= 3.70
(KJ/cycle)

Cycle 55 GMT 19/ 9/2024 23:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 32 15.16 464 225 0.23 / 202.92 2 5
2 7 2013.36 38 14.84 3014 1700 1.92 / 204.62 2 15
3 13 1489.12 18 14.92 2380 639 2.56 / 205.26 2 19
4 13 958.48 18 15.04 1683 456 3.02 / 205.72 2 20
5 13 458.60 18 15.15 982 268 3.29 / 205.98 2 20
6 8 0.08 165 15.21 305 765 4.05 / 206.75 2 14
Average= 3.69
(KJ/cycle)

Cycle 54 GMT 10/ 9/2024 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.56 32 15.16 468 227 0.23 / 198.66 2 5
2 7 2004.64 38 14.87 2985 1687 1.91 / 200.35 2 15
3 13 1585.12 18 14.91 2487 667 2.58 / 201.02 2 19
4 13 1141.04 18 14.99 1913 516 3.10 / 201.53 2 20
5 13 469.92 18 15.16 991 270 3.37 / 201.80 2 20
6 13 132.52 18 15.22 499 137 3.50 / 201.94 2 16
7 8 0.16 165 15.20 301 755 4.26 / 202.70 2 14
Average= 3.69
(KJ/cycle)

Cycle 53 GMT 31/ 8/2024 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 32 15.16 470 228 0.23 / 194.51 2 5
2 7 2004.56 38 14.85 3006 1696 1.92 / 196.20 2 16
3 13 1621.92 18 14.91 2539 681 2.61 / 196.88 2 16
4 13 964.76 18 15.02 1677 453 3.06 / 197.34 2 22
5 13 374.36 18 15.19 852 233 3.29 / 197.57 2 19
6 13 59.36 18 15.24 393 108 3.40 / 197.68 2 15
7 8 -0.12 165 15.22 302 758 4.16 / 198.44 2 24
Average= 3.67
(KJ/cycle)

Cycle 52 GMT 21/ 8/2024 14:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 32 15.17 466 226 0.23 / 190.32 2 8
2 3 981.48 -1 15.55 0 0 0.00 / 190.32 2 8
3 3 1022.84 1 15.27 1805 28 0.25 / 190.35 2 15
4 7 2004.36 38 14.84 3002 1693 1.95 / 192.04 2 17
5 13 1561.28 18 14.92 2470 663 2.61 / 192.70 2 17
6 13 963.92 18 15.04 1687 457 3.07 / 193.16 2 21
7 13 415.96 18 15.17 917 250 3.32 / 193.41 2 19
8 13 36.12 18 15.24 364 100 3.42 / 193.51 2 12
9 8 0.12 165 15.21 306 768 4.18 / 194.28 2 25
Average= 3.67
(KJ/cycle)

Cycle 51 GMT 11/ 8/2024 20: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 32 15.17 467 227 0.23 / 186.23 2 6
2 7 2011.64 38 14.84 3015 1700 1.93 / 187.93 2 16
3 13 1528.52 18 14.93 2419 650 2.58 / 188.58 2 18
4 13 1023.56 18 15.02 1760 476 3.05 / 189.06 2 21
5 13 425.08 18 15.16 944 258 3.31 / 189.32 2 22
6 8 0.20 165 15.21 309 775 4.09 / 190.09 2 27
Average= 3.66
(KJ/cycle)

Cycle 50 GMT 2/ 8/2024 1:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 32 15.18 468 227 0.23 / 182.23 2 6
2 7 2003.52 38 14.85 3002 1694 1.92 / 183.92 2 17
3 13 1431.04 18 14.95 2299 619 2.54 / 184.54 2 19
4 13 1003.44 18 15.03 1729 468 3.01 / 185.01 2 22
5 13 391.92 18 15.17 890 243 3.25 / 185.25 2 21
6 8 0.00 165 15.22 302 758 4.01 / 186.01 2 22
Average= 3.65
(KJ/cycle)

Cycle 49 GMT 23/ 7/2024 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 31 15.17 436 205 0.21 / 178.08 2 5
2 7 2005.04 38 14.85 3000 1693 1.90 / 179.77 2 17
3 13 1517.04 18 14.93 2396 644 2.54 / 180.42 2 20
4 13 1027.52 18 15.02 1755 474 3.02 / 180.89 2 21
5 13 413.60 18 15.17 913 249 3.27 / 181.14 2 20
6 13 42.24 18 15.24 366 100 3.37 / 181.24 2 15
7 8 0.16 165 15.21 301 755 4.12 / 182.00 2 24
Average= 3.64
(KJ/cycle)

Cycle 48 GMT 13/ 7/2024 11:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 31 15.17 452 213 0.21 / 173.93 2 5
2 7 1922.52 39 14.86 2903 1682 1.89 / 175.61 2 17
3 13 1556.44 18 14.94 2455 660 2.56 / 176.27 2 19
4 13 1104.52 18 15.01 1862 503 3.06 / 176.77 2 22
5 13 433.44 18 15.18 940 257 3.32 / 177.03 2 20
6 13 46.96 18 15.24 370 101 3.42 / 177.13 2 14
7 8 -0.24 165 15.22 296 743 4.16 / 177.88 2 21
Average= 3.63
(KJ/cycle)

Cycle 47 GMT 3/ 7/2024 14: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 31 15.18 448 211 0.21 / 170.00 2 5
2 7 1694.28 39 14.96 2611 1523 1.73 / 171.53 2 18
3 13 1445.80 18 15.00 2309 623 2.36 / 172.15 2 17
4 13 947.52 18 15.08 1659 450 2.81 / 172.60 2 21
5 13 334.68 18 15.22 806 221 3.03 / 172.82 2 20
6 13 111.92 18 15.25 476 131 3.16 / 172.95 2 15
7 8 0.00 165 15.24 304 764 3.92 / 173.72 2 24
Average= 3.62
(KJ/cycle)

Cycle 46 GMT 23/ 6/2024 16:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.16 31 15.21 477 225 0.22 / 166.15 2 6
2 7 1671.40 38 14.96 2577 1465 1.69 / 167.62 2 17
3 13 1523.28 18 14.97 2400 647 2.34 / 168.26 2 19
4 13 923.28 18 15.08 1626 441 2.78 / 168.71 2 22
5 13 361.72 18 15.22 851 233 3.01 / 168.94 2 21
6 13 38.52 18 15.26 361 99 3.11 / 169.04 2 17
7 8 0.04 165 15.24 300 754 3.86 / 169.79 2 21
Average= 3.61
(KJ/cycle)

Cycle 45 GMT 13/ 6/2024 19:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 31 15.21 470 222 0.22 / 162.54 2 6
2 7 1546.20 38 15.02 2418 1380 1.60 / 163.92 2 19
3 13 1405.08 18 15.04 2250 609 2.21 / 164.52 2 18
4 13 820.32 18 15.15 1482 404 2.61 / 164.93 2 21
5 13 336.72 18 15.25 806 221 2.84 / 165.15 2 19
6 8 0.36 165 15.27 309 779 3.61 / 165.93 2 22
Average= 3.61
(KJ/cycle)

Cycle 44 GMT 3/ 6/2024 22:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 31 15.21 446 210 0.21 / 158.94 2 6
2 7 1512.96 38 15.03 2380 1359 1.57 / 160.30 2 17
3 13 1420.44 18 15.03 2277 616 2.19 / 160.92 2 21
4 13 877.48 18 15.13 1557 424 2.61 / 161.34 2 21
5 13 320.28 18 15.25 774 212 2.82 / 161.56 2 20
6 8 0.08 165 15.27 301 758 3.58 / 162.31 2 16
Average= 3.61
(KJ/cycle)

Cycle 43 GMT 25/ 5/2024 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 31 15.21 461 217 0.22 / 155.40 2 5
2 7 1392.56 38 15.09 2211 1268 1.49 / 156.67 2 17
3 13 1354.28 18 15.09 2179 592 2.08 / 157.26 2 17
4 13 827.88 18 15.17 1483 405 2.48 / 157.66 2 21
5 13 281.00 18 15.27 724 199 2.68 / 157.86 2 19
6 13 57.52 18 15.30 395 109 2.79 / 157.97 2 14
7 8 -0.04 165 15.26 303 763 3.55 / 158.73 2 16
Average= 3.61
(KJ/cycle)

Cycle 42 GMT 15/ 5/2024 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 31 15.23 458 216 0.22 / 151.84 2 6
2 3 986.56 -1 15.58 0 0 0.00 / 151.84 2 6
3 3 1022.28 1 15.29 1791 27 0.24 / 151.87 2 14
4 7 1369.64 38 15.10 2172 1246 1.49 / 153.11 2 22
5 13 1331.96 18 15.09 2141 582 2.07 / 153.70 2 22
6 13 914.24 18 15.14 1596 435 2.51 / 154.13 2 21
7 13 244.64 18 15.28 671 185 2.69 / 154.32 2 18
8 13 37.72 18 15.31 360 99 2.79 / 154.41 2 16
9 8 0.12 165 15.27 304 766 3.56 / 155.18 4 19
Average= 3.61
(KJ/cycle)

Cycle 41 GMT 5/ 5/2024 8:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 31 15.21 445 210 0.21 / 148.32 2 5
2 3 987.72 -1 15.58 0 0 0.00 / 148.32 2 5
3 3 1025.08 1 15.29 1811 28 0.24 / 148.35 2 13
4 7 1390.92 38 15.10 2191 1257 1.49 / 149.60 2 20
5 13 1350.48 18 15.09 2143 582 2.08 / 150.19 2 17
6 13 865.52 18 15.16 1508 412 2.49 / 150.60 2 21
7 13 250.04 18 15.30 647 178 2.67 / 150.78 2 19
8 13 39.16 18 15.32 341 94 2.76 / 150.87 2 17
9 8 0.12 165 15.28 299 754 3.51 / 151.62 2 22
Average= 3.61
(KJ/cycle)

Cycle 40 GMT 25/ 4/2024 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 31 15.22 453 214 0.21 / 144.73 2 5
2 3 979.08 -1 15.59 0 0 0.00 / 144.73 2 5
3 3 1016.08 1 15.30 1785 27 0.24 / 144.75 2 15
4 7 1404.92 38 15.10 2232 1281 1.52 / 146.03 2 18
5 13 1364.08 18 15.08 2188 594 2.12 / 146.63 2 19
6 13 818.48 18 15.17 1480 404 2.52 / 147.03 2 20
7 13 275.40 18 15.27 715 197 2.72 / 147.23 2 19
8 13 48.36 18 15.31 385 106 2.82 / 147.33 2 17
9 8 0.00 165 15.26 308 776 3.60 / 148.11 2 21
Average= 3.61
(KJ/cycle)

Cycle 39 GMT 15/ 4/2024 15:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 31 15.21 464 219 0.22 / 141.15 2 5
2 3 988.52 -1 15.59 0 0 0.00 / 141.15 2 5
3 3 1020.44 1 15.29 1791 27 0.25 / 141.18 2 15
4 7 1314.68 38 15.13 2119 1218 1.46 / 142.39 2 19
5 13 1277.68 18 15.11 2084 567 2.03 / 142.96 2 19
6 13 958.92 18 15.15 1666 454 2.49 / 143.42 2 20
7 13 280.44 18 15.30 728 200 2.69 / 143.62 2 20
8 13 58.84 18 15.32 405 112 2.80 / 143.73 2 15
9 8 0.12 165 15.28 311 784 3.58 / 144.51 2 27
Average= 3.61
(KJ/cycle)

Cycle 38 GMT 5/ 4/2024 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 31 15.22 450 212 0.21 / 137.54 2 6
2 7 1423.00 38 15.08 2269 1300 1.51 / 138.84 2 19
3 13 1378.68 18 15.06 2219 602 2.11 / 139.44 2 23
4 13 846.92 18 15.16 1529 417 2.53 / 139.86 2 22
5 13 248.44 18 15.29 689 190 2.72 / 140.05 2 20
6 13 42.08 18 15.31 382 105 2.83 / 140.15 2 18
7 8 0.16 165 15.27 308 776 3.60 / 140.93 2 23
Average= 3.61
(KJ/cycle)

Cycle 37 GMT 26/ 3/2024 22:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 31 15.23 466 220 0.22 / 134.07 2 6
2 3 987.20 -1 15.60 0 0 0.00 / 134.07 2 6
3 3 1022.08 1 15.32 1799 28 0.25 / 134.10 2 14
4 7 1279.96 38 15.13 2066 1188 1.44 / 135.29 2 18
5 13 1243.84 18 15.12 2046 557 1.99 / 135.85 2 19
6 13 874.76 18 15.18 1550 424 2.42 / 136.27 2 21
7 13 250.28 18 15.30 679 187 2.60 / 136.46 2 18
8 13 40.44 18 15.33 367 101 2.70 / 136.56 2 18
9 8 0.00 165 15.30 305 770 3.47 / 137.33 2 26
Average= 3.61
(KJ/cycle)

Cycle 36 GMT 17/ 3/2024 1:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 31 15.22 462 218 0.22 / 130.73 2 4
2 7 1249.64 38 15.16 2028 1168 1.39 / 131.89 2 20
3 13 1212.64 18 15.14 1996 544 1.93 / 132.44 2 20
4 13 745.80 18 15.22 1377 377 2.31 / 132.81 2 22
5 13 212.08 18 15.31 621 171 2.48 / 132.99 2 18
6 13 28.20 18 15.34 356 98 2.58 / 133.08 2 13
7 8 -0.08 165 15.29 305 769 3.35 / 133.85 2 20
Average= 3.62
(KJ/cycle)

Cycle 35 GMT 7/ 3/2024 5:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 31 15.23 442 209 0.21 / 127.06 2 4
2 7 1406.80 38 15.10 2237 1284 1.49 / 128.35 2 22
3 13 1405.16 18 15.07 2259 613 2.11 / 128.96 2 20
4 13 919.88 18 15.14 1627 443 2.55 / 129.40 2 21
5 13 323.12 18 15.27 787 216 2.76 / 129.62 2 19
6 13 48.84 18 15.31 389 107 2.87 / 129.73 2 14
7 8 0.20 165 15.27 310 781 3.65 / 130.51 2 19
Average= 3.63
(KJ/cycle)

Cycle 34 GMT 26/ 2/2024 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 31 15.23 461 218 0.22 / 123.52 2 5
2 3 1017.12 1 15.30 1776 27 0.24 / 123.55 2 12
3 7 1320.92 39 15.13 2124 1253 1.50 / 124.80 2 17
4 13 1282.32 18 15.12 2089 569 2.07 / 125.37 2 18
5 13 858.76 18 15.20 1535 420 2.49 / 125.79 2 21
6 13 256.48 18 15.30 691 190 2.68 / 125.98 2 18
7 13 49.52 18 15.32 387 107 2.78 / 126.09 2 17
8 8 -0.08 165 15.28 305 769 3.55 / 126.85 2 24
Average= 3.62
(KJ/cycle)

Cycle 33 GMT 16/ 2/2024 12: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.88 31 15.24 455 215 0.21 / 120.06 2 4
2 7 1302.44 38 15.15 2093 1205 1.42 / 121.27 2 18
3 13 1264.20 18 15.14 2059 561 1.98 / 121.83 2 19
4 13 844.20 18 15.21 1512 414 2.39 / 122.24 2 20
5 13 288.76 18 15.30 730 201 2.60 / 122.44 2 18
6 13 35.52 18 15.34 361 100 2.70 / 122.54 2 13
7 8 0.16 165 15.29 301 759 3.46 / 123.30 2 20
Average= 3.63
(KJ/cycle)

Cycle 32 GMT 6/ 2/2024 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 31 15.25 457 216 0.22 / 116.67 2 5
2 7 1282.44 38 15.17 2064 1190 1.41 / 117.86 2 19
3 13 1245.56 18 15.15 2036 555 1.96 / 118.42 2 18
4 13 783.80 18 15.24 1430 392 2.35 / 118.81 2 21
5 13 253.16 18 15.32 679 187 2.54 / 119.00 2 19
6 13 44.04 18 15.34 371 102 2.64 / 119.10 2 17
7 8 0.08 165 15.30 296 747 3.39 / 119.85 2 23
Average= 3.63
(KJ/cycle)

Cycle 31 GMT 27/ 1/2024 19: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 31 15.25 449 212 0.21 / 113.27 2 6
2 7 1273.36 38 15.17 2051 1182 1.39 / 114.45 2 17
3 13 1236.60 18 15.16 2014 550 1.94 / 115.00 2 19
4 13 859.96 18 15.21 1525 418 2.36 / 115.42 2 22
5 13 229.00 18 15.34 649 179 2.54 / 115.60 2 18
6 13 27.32 18 15.36 347 96 2.64 / 115.69 2 17
7 8 0.08 165 15.32 302 763 3.40 / 116.46 2 26
Average= 3.64
(KJ/cycle)

Cycle 30 GMT 17/ 1/2024 22:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 31 15.25 436 206 0.21 / 109.96 2 5
2 7 1235.80 38 15.20 2002 1156 1.36 / 111.11 2 18
3 13 1207.64 18 15.18 1978 540 1.90 / 111.65 2 19
4 13 776.72 18 15.24 1429 392 2.29 / 112.05 2 21
5 13 170.08 18 15.35 567 157 2.45 / 112.20 2 19
6 13 12.52 18 15.36 327 90 2.54 / 112.29 2 17
7 8 -0.12 165 15.31 302 763 3.30 / 113.06 2 28
Average= 3.65
(KJ/cycle)

Cycle 29 GMT 8/ 1/2024 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.44 31 15.25 453 214 0.21 / 106.43 2 4
2 3 986.60 -1 15.64 0 0 0.00 / 106.43 2 4
3 7 1371.24 38 15.15 2176 1253 1.47 / 107.69 2 19
4 13 1330.68 18 15.13 2141 583 2.05 / 108.27 2 18
5 13 889.36 18 15.22 1569 430 2.48 / 108.70 2 20
6 13 312.16 18 15.31 767 211 2.69 / 108.91 2 20
7 13 19.80 18 15.36 338 93 2.78 / 109.00 2 18
8 8 0.16 165 15.31 296 748 3.53 / 109.75 2 15
Average= 3.66
(KJ/cycle)

Cycle 28 GMT 29/12/2023 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 31 15.27 456 216 0.22 / 102.97 2 6
2 7 1332.84 39 15.17 2123 1256 1.47 / 104.23 2 20
3 13 1292.64 18 15.15 2078 567 2.04 / 104.80 2 19
4 13 724.48 18 15.26 1339 368 2.41 / 105.16 2 22
5 13 309.44 18 15.32 754 208 2.61 / 105.37 2 20
6 13 33.80 18 15.36 355 98 2.71 / 105.47 2 17
7 8 -0.04 165 15.32 296 748 3.46 / 106.22 2 23
Average= 3.66
(KJ/cycle)

Cycle 27 GMT 19/12/2023 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 15.26 430 197 0.20 / 99.59 2 5
2 7 1267.24 39 15.19 2040 1209 1.41 / 100.80 2 18
3 13 1231.28 18 15.18 1997 546 1.95 / 101.34 2 17
4 13 814.20 18 15.25 1456 400 2.35 / 101.74 2 21
5 13 308.44 18 15.32 745 205 2.56 / 101.95 2 19
6 13 19.56 18 15.35 322 89 2.65 / 102.04 2 20
7 8 0.04 165 15.31 286 722 3.37 / 102.76 2 19
Average= 3.67
(KJ/cycle)

Cycle 26 GMT 9/12/2023 12:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 31 15.29 451 214 0.21 / 96.29 2 6
2 7 1240.92 38 15.20 1994 1152 1.37 / 97.45 2 20
3 13 1205.00 18 15.19 1957 535 1.90 / 97.98 2 20
4 13 789.56 18 15.24 1429 392 2.29 / 98.37 2 20
5 13 291.60 18 15.32 723 199 2.49 / 98.57 2 19
6 13 28.04 18 15.36 336 93 2.58 / 98.67 2 20
7 8 0.12 165 15.32 287 725 3.31 / 99.39 2 25
Average= 3.68
(KJ/cycle)

Cycle 25 GMT 29/11/2023 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 31 15.28 450 213 0.21 / 93.12 2 7
2 7 1198.48 38 15.22 1951 1128 1.34 / 94.25 2 20
3 13 1163.68 18 15.21 1911 523 1.86 / 94.77 2 19
4 13 847.16 18 15.25 1494 410 2.27 / 95.18 2 21
5 13 180.24 18 15.38 568 157 2.43 / 95.34 2 19
6 8 0.04 165 15.35 292 740 3.17 / 96.08 2 22
Average= 3.70
(KJ/cycle)

Cycle 24 GMT 19/11/2023 20: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 31 15.28 435 206 0.21 / 89.93 2 6
2 7 1237.48 38 15.21 1990 1150 1.36 / 91.08 2 18
3 13 1201.20 18 15.19 1964 537 1.89 / 91.62 2 21
4 13 762.84 18 15.26 1389 382 2.27 / 92.00 2 23
5 13 223.28 18 15.35 618 171 2.45 / 92.17 2 20
6 8 0.08 165 15.34 291 737 3.18 / 92.91 2 25
Average= 3.72
(KJ/cycle)

Cycle 23 GMT 9/11/2023 23:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 30 15.28 440 202 0.20 / 86.65 2 5
2 7 1309.20 38 15.17 2087 1203 1.40 / 87.86 2 19
3 13 1269.48 18 15.16 2044 558 1.96 / 88.41 2 18
4 13 841.72 18 15.24 1488 408 2.37 / 88.82 2 21
5 13 273.24 18 15.33 688 190 2.56 / 89.01 2 20
6 8 0.16 165 15.34 282 714 3.27 / 89.73 2 26
Average= 3.74
(KJ/cycle)

Cycle 22 GMT 31/10/2023 3:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 30 15.31 425 195 0.20 / 83.32 2 8
2 7 1324.16 39 15.20 2103 1247 1.44 / 84.57 2 18
3 13 1283.72 18 15.18 2050 560 2.00 / 85.13 2 21
4 13 899.16 18 15.24 1548 425 2.43 / 85.55 2 21
5 13 282.80 18 15.35 683 189 2.62 / 85.74 2 19
6 8 0.12 165 15.34 280 709 3.32 / 86.45 2 28
Average= 3.76
(KJ/cycle)

Cycle 21 GMT 21/10/2023 6:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 30 15.26 427 195 0.20 / 80.11 2 7
2 7 1353.68 38 15.17 2131 1228 1.42 / 81.34 2 22
3 13 1312.36 18 15.16 2087 570 1.99 / 81.91 2 20
4 13 778.96 18 15.27 1381 380 2.37 / 82.29 2 21
5 13 236.64 18 15.36 611 169 2.54 / 82.46 2 18
6 8 -0.04 165 15.35 265 671 3.21 / 83.13 2 13
Average= 3.78
(KJ/cycle)

Cycle 20 GMT 11/10/2023 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 30 15.27 419 192 0.19 / 76.19 2 8
2 7 2011.64 38 14.95 2975 1690 1.88 / 77.88 2 15
3 13 1570.72 18 15.03 2434 658 2.54 / 78.54 2 18
4 13 1009.64 18 15.13 1702 464 3.00 / 79.00 2 22
5 13 401.12 18 15.26 859 236 3.24 / 79.24 2 22
6 8 0.00 165 15.31 269 680 3.92 / 79.92 2 28
Average= 3.81
(KJ/cycle)

Cycle 19 GMT 1/10/2023 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 30 15.27 421 193 0.19 / 72.31 2 8
2 7 2010.52 38 14.94 2964 1683 1.88 / 73.99 2 18
3 13 1561.92 18 15.01 2419 654 2.53 / 74.64 2 19
4 13 968.28 18 15.13 1641 447 2.98 / 75.09 2 23
5 13 363.68 18 15.27 809 222 3.20 / 75.31 2 21
6 8 0.16 165 15.32 271 685 3.88 / 76.00 2 28
Average= 3.80
(KJ/cycle)

Cycle 18 GMT 21/ 9/2023 20:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 30 15.26 432 198 0.20 / 68.48 2 8
2 7 2006.04 38 14.94 2974 1688 1.89 / 70.17 2 15
3 13 1504.12 18 15.05 2350 637 2.52 / 70.81 2 19
4 13 902.04 18 15.15 1549 422 2.95 / 71.23 2 21
5 13 304.80 18 15.29 717 197 3.14 / 71.43 2 20
6 8 0.00 165 15.32 270 683 3.83 / 72.11 2 26
Average= 3.80
(KJ/cycle)

Cycle 17 GMT 12/ 9/2023 1:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 30 15.26 419 192 0.19 / 64.59 2 9
2 7 2007.24 39 14.96 2981 1739 1.93 / 66.33 2 17
3 13 1376.44 18 15.07 2184 592 2.52 / 66.92 2 20
4 13 860.00 18 15.17 1504 411 2.93 / 67.33 2 22
5 13 476.24 18 15.25 970 266 3.20 / 67.60 2 22
6 8 0.16 165 15.31 272 687 3.89 / 68.29 2 27
Average= 3.79
(KJ/cycle)

Cycle 16 GMT 2/ 9/2023 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 30 15.27 425 195 0.19 / 60.70 2 7
2 7 2010.28 38 14.96 2985 1697 1.89 / 62.40 2 16
3 13 1487.44 18 15.04 2330 631 2.52 / 63.03 2 19
4 13 988.56 18 15.13 1667 454 2.98 / 63.48 2 21
5 13 412.92 18 15.27 877 241 3.22 / 63.72 2 21
6 8 -0.04 165 15.32 268 677 3.89 / 64.40 2 22
Average= 3.79
(KJ/cycle)

Cycle 15 GMT 23/ 8/2023 11:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 30 15.28 425 195 0.19 / 56.88 2 7
2 7 2006.00 38 14.96 2971 1689 1.88 / 58.57 2 16
3 13 1412.64 18 15.07 2223 603 2.49 / 59.17 2 19
4 13 890.72 18 15.17 1536 419 2.91 / 59.59 2 21
5 13 393.48 18 15.28 848 233 3.14 / 59.83 2 21
6 8 0.20 165 15.32 268 677 3.82 / 60.50 2 21
Average= 3.78
(KJ/cycle)

Cycle 14 GMT 13/ 8/2023 15:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 30 15.30 411 189 0.19 / 53.00 2 8
2 7 2006.76 38 14.98 2983 1698 1.89 / 54.69 2 15
3 13 1524.20 18 15.06 2384 646 2.53 / 55.34 2 19
4 13 985.52 18 15.16 1666 455 2.99 / 55.79 2 21
5 13 368.64 18 15.30 810 223 3.21 / 56.02 2 21
6 8 -0.08 165 15.34 265 671 3.88 / 56.69 2 27
Average= 3.78
(KJ/cycle)

Cycle 13 GMT 3/ 8/2023 20:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 30 15.29 423 194 0.19 / 49.15 2 7
2 7 2003.76 38 14.98 2966 1688 1.88 / 50.84 2 16
3 13 1513.12 18 15.07 2367 642 2.52 / 51.48 2 19
4 13 972.48 18 15.16 1650 450 2.97 / 51.93 2 22
5 13 327.92 18 15.31 751 207 3.18 / 52.14 2 20
6 8 0.12 165 15.34 265 671 3.85 / 52.81 2 22
Average= 3.77
(KJ/cycle)

Cycle 12 GMT 25/ 7/2023 1:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 30 15.29 423 194 0.19 / 45.32 2 7
2 7 2004.16 38 15.00 2966 1691 1.88 / 47.01 2 15
3 13 1436.08 18 15.09 2261 614 2.50 / 47.63 2 20
4 13 914.48 18 15.18 1572 430 2.93 / 48.06 2 21
5 13 360.68 18 15.31 800 220 3.15 / 48.28 2 21
6 8 0.16 165 15.34 268 678 3.83 / 48.95 2 26
Average= 3.77
(KJ/cycle)

Cycle 11 GMT 15/ 7/2023 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 30 15.29 429 197 0.20 / 40.74 2 7
2 3 1018.16 1 15.37 1749 27 0.22 / 40.76 2 16
3 7 2002.88 75 14.86 2964 3303 3.53 / 44.07 2 17
4 13 551.60 18 15.26 1082 297 3.82 / 44.36 2 23
5 13 19.68 18 15.36 304 84 3.91 / 44.45 2 13
6 8 0.16 165 15.32 269 680 4.59 / 45.13 2 24
Average= 3.76
(KJ/cycle)

Cycle 10 GMT 5/ 7/2023 9:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.27 430 197 0.20 / 36.22 2 7
2 3 1018.64 1 15.38 1774 27 0.22 / 36.25 2 15
3 7 2003.52 74 14.87 2960 3257 3.48 / 39.51 2 16
4 13 424.84 18 15.30 893 246 3.73 / 39.75 2 22
5 13 85.76 18 15.36 397 110 3.84 / 39.86 2 18
6 8 0.04 165 15.34 267 676 4.51 / 40.54 2 28
Average= 3.69
(KJ/cycle)

Cycle 9 GMT 25/ 6/2023 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 29 15.28 426 189 0.19 / 31.69 2 6
2 3 1036.08 1 15.35 1792 28 0.22 / 31.72 2 16
3 7 2004.52 74 14.86 2960 3255 3.47 / 34.97 2 16
4 13 484.48 18 15.27 980 269 3.74 / 35.24 2 22
5 13 80.32 18 15.36 392 108 3.85 / 35.35 2 18
6 8 0.04 165 15.33 268 678 4.53 / 36.03 2 27
Average= 3.60
(KJ/cycle)

Cycle 8 GMT 15/ 6/2023 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 30 15.28 417 191 0.19 / 27.20 2 6
2 3 965.56 -1 15.69 0 0 0.00 / 27.20 2 6
3 7 2003.32 74 14.86 2951 3245 3.44 / 30.45 2 16
4 13 483.96 18 15.28 980 270 3.71 / 30.72 2 22
5 13 75.68 18 15.35 385 106 3.81 / 30.82 2 19
6 8 -0.04 165 15.33 267 675 4.49 / 31.50 2 22
Average= 3.50
(KJ/cycle)

Cycle 7 GMT 5/ 6/2023 17:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 28 15.27 425 182 0.18 / 23.05 2 6
2 7 1778.60 74 14.95 2669 2953 3.13 / 26.00 2 17
3 13 399.80 18 15.30 855 235 3.37 / 26.24 2 21
4 13 50.00 18 15.36 347 96 3.47 / 26.33 2 18
5 8 0.00 165 15.34 268 678 4.14 / 27.01 2 25
Average= 3.38
(KJ/cycle)

Cycle 6 GMT 4/ 6/2023 17: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 28 15.31 400 171 0.17 / 18.95 2 6
2 7 1759.68 74 14.95 2639 2920 3.09 / 21.87 2 16
3 13 388.92 18 15.30 839 231 3.32 / 22.10 2 21
4 13 45.32 18 15.36 339 94 3.42 / 22.19 2 17
5 8 0.08 165 15.33 267 675 4.09 / 22.87 2 31
Average= 3.27
(KJ/cycle)

Cycle 5 GMT 3/ 6/2023 16:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 28 15.29 423 181 0.18 / 15.33 2 6
2 7 1507.64 75 15.05 2313 2611 2.79 / 17.95 2 16
3 13 225.24 18 15.34 597 165 2.96 / 18.11 2 18
4 8 0.08 165 15.34 263 666 3.62 / 18.78 2 18
Average= 3.13
(KJ/cycle)

Cycle 4 GMT 2/ 6/2023 16:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 28 15.29 415 178 0.18 / 11.60 2 5
2 3 1016.80 1 15.37 1753 27 0.20 / 11.62 2 16
3 7 1519.28 74 15.05 2333 2598 2.80 / 14.22 2 16
4 13 262.84 18 15.34 652 180 2.98 / 14.40 2 19
5 13 19.44 18 15.38 297 82 3.07 / 14.48 2 19
6 8 0.04 165 15.34 265 671 3.74 / 15.15 2 27
Average= 3.03
(KJ/cycle)

Cycle 3 GMT 1/ 6/2023 16:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 25 15.30 417 160 0.16 / 7.89 2 5
2 10 1013.72 3 15.33 1691 78 0.24 / 7.97 2 10
3 7 1525.12 74 15.05 2341 2607 2.84 / 10.58 2 16
4 13 250.24 18 15.35 636 176 3.02 / 10.75 2 20
5 8 0.12 165 15.35 263 666 3.69 / 11.42 2 17
Average= 2.85
(KJ/cycle)

Cycle 2 GMT 31/ 5/2023 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 33 15.32 430 217 0.22 / 4.34 2 6
2 3 830.60 -3 15.68 0 0 0.00 / 4.34 2 6
3 3 886.64 -2 15.71 0 0 0.00 / 4.34 2 6
4 7 1520.84 74 15.05 2326 2590 2.81 / 6.93 2 17
5 13 165.88 18 15.36 506 140 2.95 / 7.07 2 18
6 8 0.16 165 15.35 263 666 3.61 / 7.73 2 25
Average= 2.58
(KJ/cycle)

Cycle 1 GMT 30/ 5/2023 17:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 28 15.51 392 170 0.17 / 1.58 2 4
2 7 999.60 74 15.23 1639 1847 2.02 / 3.43 2 19
3 8 -0.12 165 15.40 270 686 2.70 / 4.12 2 21
Average= 2.06
(KJ/cycle)

Cycle 0 GMT 30/ 5/2023 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 82.60 27 15.64 356 150 0.15 / 0.15 2 5
2 7 97.44 74 15.61 369 426 0.58 / 0.58 2 8
3 8 0.12 240 15.58 224 838 1.41 / 1.41 2 20
Average= 1.41
(KJ/cycle)