SIO Argo Site:
Pump Diagnostics Page   



Serial= 3181 WMO= 5906920

Return

←PreviousNext→

Cycle 65 GMT 22/12/2024 23:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 34 15.20 471 243 0.24 / 263.35 2 5
2 7 2007.92 38 14.88 2941 1663 1.91 / 265.02 2 9
3 13 1545.48 18 14.92 2383 640 2.55 / 265.66 2 13
4 13 1022.72 18 15.00 1708 461 3.01 / 266.12 2 15
5 13 597.52 18 15.09 1156 314 3.32 / 266.43 2 16
6 13 85.36 18 15.20 449 123 3.44 / 266.55 2 21
7 8 0.12 165 15.17 316 791 4.24 / 267.34 2 13
Average= 4.05
(KJ/cycle)

Cycle 64 GMT 13/12/2024 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 34 15.14 478 246 0.25 / 260.25 2 3
2 7 1063.20 39 15.23 1743 1035 1.28 / 261.29 2 12
3 13 1042.76 18 15.21 1727 473 1.75 / 261.76 2 13
4 13 796.84 18 15.21 1399 383 2.14 / 262.15 2 14
5 13 211.64 18 15.28 618 170 2.31 / 262.32 2 12
6 8 0.04 165 15.27 315 794 3.10 / 263.11 2 17
Average= 4.05
(KJ/cycle)

Cycle 63 GMT 3/12/2024 8:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 34 15.17 471 243 0.24 / 255.95 2 4
2 7 2005.64 38 14.91 2939 1665 1.91 / 257.62 2 11
3 13 1606.48 18 14.95 2457 661 2.57 / 258.28 2 11
4 13 1181.04 18 14.98 1919 517 3.09 / 258.79 2 15
5 13 563.72 18 15.13 1112 303 3.39 / 259.10 2 17
6 13 27.28 18 15.22 368 101 3.49 / 259.20 2 7
7 8 0.12 165 15.20 323 810 4.30 / 260.01 2 15
Average= 4.06
(KJ/cycle)

Cycle 62 GMT 23/11/2024 13:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 34 15.15 482 248 0.25 / 251.66 2 4
2 7 2006.68 38 14.92 2946 1670 1.92 / 253.33 2 8
3 13 1746.44 18 14.92 2637 708 2.63 / 254.03 2 11
4 13 1071.32 18 15.03 1778 481 3.11 / 254.52 2 14
5 13 543.44 18 15.14 1088 297 3.40 / 254.81 2 15
6 13 30.12 18 15.24 366 100 3.50 / 254.91 2 2
7 8 0.20 165 15.21 317 796 4.30 / 255.71 2 3
Average= 4.06
(KJ/cycle)

Cycle 61 GMT 13/11/2024 18:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 33 15.15 480 240 0.24 / 247.29 2 4
2 7 2015.16 38 14.91 2957 1675 1.92 / 248.97 2 9
3 13 1579.68 18 14.95 2426 653 2.57 / 249.62 2 12
4 13 1307.96 18 14.97 2078 560 3.13 / 250.18 2 14
5 13 591.40 18 15.11 1151 313 3.44 / 250.50 2 16
6 13 24.32 18 15.24 364 100 3.54 / 250.60 2 23
7 8 0.08 165 15.20 324 813 4.35 / 251.41 2 33
Average= 4.05
(KJ/cycle)

Cycle 60 GMT 3/11/2024 23: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 33 15.18 480 240 0.24 / 243.04 2 4
2 7 2012.16 38 14.92 2948 1671 1.91 / 244.72 2 10
3 13 1616.68 18 14.94 2474 665 2.58 / 245.38 2 12
4 13 1041.92 18 15.04 1726 467 3.04 / 245.85 2 14
5 13 560.80 18 15.13 1106 301 3.35 / 246.15 2 16
6 13 15.44 18 15.24 343 94 3.44 / 246.24 2 13
7 8 0.12 165 15.20 323 810 4.25 / 247.05 2 5
Average= 4.05
(KJ/cycle)

Cycle 59 GMT 25/10/2024 3:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 33 15.17 488 244 0.24 / 238.85 2 4
2 7 2011.32 38 14.92 2950 1673 1.92 / 240.52 2 10
3 13 1548.48 18 14.96 2386 643 2.56 / 241.17 2 12
4 13 1230.56 18 14.99 1972 532 3.09 / 241.70 2 14
5 13 557.24 18 15.13 1102 300 3.39 / 242.00 2 16
6 8 0.00 165 15.22 321 806 4.20 / 242.80 2 9
Average= 4.05
(KJ/cycle)

Cycle 58 GMT 15/10/2024 8:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 33 15.18 486 243 0.24 / 234.62 2 7
2 7 2010.32 39 14.91 2941 1710 1.95 / 236.33 2 8
3 13 1588.36 18 14.95 2433 655 2.61 / 236.99 2 12
4 13 1209.40 18 15.00 1948 526 3.13 / 237.51 2 14
5 13 493.76 18 15.18 1020 279 3.41 / 237.79 2 15
6 8 0.12 165 15.23 324 814 4.23 / 238.61 2 21
Average= 4.04
(KJ/cycle)

Cycle 57 GMT 5/10/2024 13:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 33 15.19 485 243 0.24 / 230.31 2 5
2 7 2006.60 38 14.92 2944 1669 1.91 / 231.98 2 9
3 13 1574.00 18 14.97 2424 653 2.57 / 232.64 2 12
4 13 1196.68 18 15.01 1940 524 3.09 / 233.16 2 15
5 13 553.28 18 15.16 1102 301 3.39 / 233.46 2 16
6 13 22.80 18 15.27 359 99 3.49 / 233.56 2 21
7 8 -0.04 165 15.23 326 819 4.31 / 234.38 2 5
Average= 4.04
(KJ/cycle)

Cycle 56 GMT 25/ 9/2024 18:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 33 15.19 484 243 0.24 / 226.07 2 5
2 7 2006.84 39 14.92 2946 1714 1.96 / 227.79 2 10
3 13 1699.44 18 14.95 2574 693 2.65 / 228.48 2 13
4 13 1049.36 18 15.06 1750 474 3.12 / 228.96 2 15
5 13 557.80 18 15.15 1104 301 3.42 / 229.26 2 16
6 8 0.28 165 15.23 324 814 4.24 / 230.07 2 4
Average= 4.04
(KJ/cycle)

Cycle 55 GMT 16/ 9/2024 0: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 33 15.19 485 243 0.24 / 221.81 2 5
2 7 2003.52 38 14.94 2941 1670 1.91 / 223.48 2 10
3 13 1630.88 18 14.97 2501 674 2.59 / 224.16 2 15
4 13 1096.40 18 15.04 1813 491 3.08 / 224.65 2 15
5 13 498.32 18 15.19 1025 280 3.36 / 224.93 2 15
6 13 24.04 18 15.27 361 99 3.46 / 225.03 2 14
7 8 -0.04 165 15.23 321 807 4.26 / 225.83 2 14
Average= 4.03
(KJ/cycle)

Cycle 54 GMT 6/ 9/2024 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 33 15.19 489 245 0.25 / 217.61 2 5
2 7 2008.24 38 14.92 2954 1675 1.92 / 219.28 2 11
3 13 1595.08 18 14.97 2460 663 2.58 / 219.95 2 15
4 13 1070.28 18 15.06 1794 486 3.07 / 220.43 2 15
5 13 581.04 18 15.16 1147 313 3.38 / 220.75 2 16
6 8 0.16 165 15.24 327 822 4.20 / 221.57 2 9
Average= 4.03
(KJ/cycle)

Cycle 53 GMT 27/ 8/2024 9:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 33 15.20 469 235 0.24 / 213.38 2 5
2 7 2013.68 38 14.94 2961 1681 1.92 / 215.06 2 12
3 13 1543.32 18 14.98 2384 643 2.56 / 215.71 2 14
4 13 1175.92 18 15.04 1921 520 3.08 / 216.23 2 15
5 13 597.28 18 15.17 1158 316 3.40 / 216.54 2 16
6 8 0.24 165 15.25 326 820 4.22 / 217.36 2 8
Average= 4.03
(KJ/cycle)

Cycle 52 GMT 17/ 8/2024 14:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 33 15.19 483 242 0.24 / 209.25 2 4
2 7 2007.92 38 14.95 2949 1675 1.92 / 210.93 2 10
3 13 1549.40 18 15.00 2382 643 2.56 / 211.57 2 12
4 13 1077.40 18 15.07 1786 484 3.05 / 212.05 2 14
5 13 509.20 18 15.19 1030 282 3.33 / 212.34 2 15
6 8 0.00 165 15.26 323 813 4.14 / 213.15 2 12
Average= 4.02
(KJ/cycle)

Cycle 51 GMT 7/ 8/2024 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 33 15.20 486 244 0.24 / 204.90 2 5
2 7 2011.80 38 14.94 2946 1673 1.92 / 206.57 2 10
3 13 1814.16 18 14.94 2713 730 2.65 / 207.30 2 11
4 13 1080.40 18 15.05 1789 485 3.13 / 207.78 2 15
5 13 596.80 18 15.16 1151 314 3.44 / 208.10 2 16
6 13 20.84 18 15.29 354 97 3.54 / 208.20 2 16
7 8 0.16 165 15.24 323 812 4.35 / 209.01 2 14
Average= 4.02
(KJ/cycle)

Cycle 50 GMT 29/ 7/2024 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 33 15.21 475 238 0.24 / 200.61 2 6
2 7 2012.12 39 14.95 2958 1725 1.96 / 202.34 2 9
3 13 1548.20 18 15.00 2397 647 2.61 / 202.98 2 12
4 13 1023.40 18 15.08 1721 467 3.08 / 203.45 2 15
5 13 545.44 18 15.17 1085 296 3.37 / 203.75 2 16
6 13 21.20 18 15.30 356 98 3.47 / 203.84 2 13
7 8 0.16 165 15.25 322 810 4.28 / 204.65 2 8
Average= 4.01
(KJ/cycle)

Cycle 49 GMT 19/ 7/2024 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 33 15.21 474 238 0.24 / 196.47 2 5
2 7 2003.36 38 14.95 2947 1674 1.91 / 198.14 2 9
3 13 1555.96 18 15.00 2401 648 2.56 / 198.79 2 13
4 13 1089.20 18 15.06 1800 488 3.05 / 199.28 2 15
5 13 492.96 18 15.20 1028 281 3.33 / 199.56 2 16
6 8 -0.16 165 15.26 323 813 4.14 / 200.37 2 20
Average= 4.01
(KJ/cycle)

Cycle 48 GMT 9/ 7/2024 10:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 33 15.21 490 246 0.25 / 192.07 2 4
2 7 2006.76 39 14.95 2956 1723 1.97 / 193.79 2 10
3 13 1684.68 18 14.98 2572 694 2.66 / 194.49 2 12
4 13 1145.64 18 15.06 1881 510 3.17 / 195.00 2 14
5 13 599.12 18 15.17 1167 319 3.49 / 195.31 2 15
6 13 19.12 18 15.30 355 98 3.59 / 195.41 2 9
7 8 0.20 165 15.25 325 818 4.41 / 196.23 2 11
Average= 4.00
(KJ/cycle)

Cycle 47 GMT 29/ 6/2024 15:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 33 15.21 481 241 0.24 / 187.68 2 4
2 7 2012.64 38 14.94 2955 1678 1.92 / 189.36 2 10
3 13 1633.56 18 15.00 2492 673 2.59 / 190.03 2 12
4 13 1186.44 18 15.05 1928 522 3.11 / 190.55 2 15
5 13 623.36 18 15.16 1197 327 3.44 / 190.88 2 16
6 13 25.68 18 15.29 372 102 3.54 / 190.98 2 4
7 8 0.24 165 15.25 334 840 4.38 / 191.82 2 12
Average= 4.00
(KJ/cycle)

Cycle 46 GMT 19/ 6/2024 20:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 33 15.23 484 243 0.24 / 183.31 2 5
2 7 2009.28 38 14.96 2955 1680 1.92 / 184.99 2 10
3 13 1637.36 18 14.98 2503 675 2.60 / 185.67 2 11
4 13 1196.44 18 15.05 1958 530 3.13 / 186.20 2 14
5 13 519.76 18 15.20 1065 291 3.42 / 186.49 2 16
6 13 63.12 18 15.29 432 119 3.54 / 186.61 2 12
7 8 0.12 165 15.25 331 833 4.37 / 187.44 2 17
Average= 3.99
(KJ/cycle)

Cycle 45 GMT 10/ 6/2024 1:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 33 15.22 488 245 0.25 / 179.07 2 5
2 7 2014.88 39 14.96 2961 1728 1.97 / 180.80 2 10
3 13 1585.64 18 15.00 2453 662 2.63 / 181.46 2 12
4 13 1099.16 18 15.07 1813 492 3.13 / 181.95 2 15
5 13 502.60 18 15.21 1036 284 3.41 / 182.24 2 16
6 8 -0.08 165 15.27 330 831 4.24 / 183.07 2 14
Average= 3.98
(KJ/cycle)

Cycle 44 GMT 31/ 5/2024 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 33 15.22 478 240 0.24 / 174.65 2 5
2 7 2017.68 38 14.97 2972 1691 1.93 / 176.34 2 10
3 13 1971.20 18 14.94 2919 785 2.72 / 177.12 2 11
4 13 1024.92 18 15.11 1724 469 3.18 / 177.59 2 15
5 13 537.52 18 15.21 1081 296 3.48 / 177.89 2 15
6 13 39.52 18 15.29 396 109 3.59 / 178.00 2 4
7 8 0.32 165 15.26 329 828 4.42 / 178.83 2 16
Average= 3.97
(KJ/cycle)

Cycle 43 GMT 21/ 5/2024 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 33 15.23 484 243 0.24 / 170.28 2 4
2 7 2004.84 38 14.99 2953 1682 1.93 / 171.97 2 10
3 13 1694.64 18 15.00 2576 696 2.62 / 172.66 2 14
4 13 1137.88 18 15.07 1882 511 3.13 / 173.17 2 14
5 13 487.44 18 15.23 1023 280 3.41 / 173.45 2 16
6 13 89.28 18 15.30 467 129 3.54 / 173.58 2 12
7 8 -0.04 165 15.27 328 826 4.37 / 174.41 2 17
Average= 3.96
(KJ/cycle)

Cycle 42 GMT 11/ 5/2024 16:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 32 15.22 484 236 0.24 / 166.02 2 5
2 7 2005.28 38 14.97 2962 1685 1.92 / 167.71 2 12
3 13 1510.80 18 15.03 2350 636 2.56 / 168.34 2 14
4 13 1094.32 18 15.08 1831 497 3.05 / 168.84 2 14
5 13 442.76 18 15.22 959 263 3.32 / 169.10 2 15
6 13 24.16 18 15.32 370 102 3.42 / 169.21 2 8
7 8 0.00 165 15.27 331 834 4.25 / 170.04 2 14
Average= 3.95
(KJ/cycle)

Cycle 41 GMT 1/ 5/2024 21:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 32 15.23 483 235 0.24 / 161.60 2 5
2 7 2005.20 38 14.97 2960 1684 1.92 / 163.29 2 11
3 13 1701.80 18 15.00 2601 702 2.62 / 163.99 2 12
4 13 1185.12 18 15.08 1944 528 3.15 / 164.52 2 15
5 13 562.40 18 15.20 1121 307 3.46 / 164.82 2 16
6 13 70.60 18 15.31 448 123 3.58 / 164.95 2 16
7 8 -0.04 165 15.27 334 842 4.42 / 165.79 2 10
Average= 3.95
(KJ/cycle)

Cycle 40 GMT 22/ 4/2024 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 32 15.22 492 240 0.24 / 157.36 2 4
2 7 1965.84 38 14.95 2913 1655 1.89 / 159.02 2 10
3 13 1502.88 18 15.03 2349 635 2.53 / 159.65 2 13
4 13 1057.04 18 15.10 1776 483 3.01 / 160.13 2 16
5 13 460.32 18 15.23 989 271 3.28 / 160.41 2 16
6 13 58.84 18 15.30 429 118 3.40 / 160.52 2 14
7 8 0.16 165 15.27 335 844 4.25 / 161.37 2 18
Average= 3.94
(KJ/cycle)

Cycle 39 GMT 12/ 4/2024 4:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 32 15.22 469 228 0.23 / 153.23 2 4
2 7 1818.40 38 15.02 2712 1548 1.78 / 154.78 2 11
3 13 1617.52 18 15.04 2489 674 2.45 / 155.45 2 14
4 13 1018.36 18 15.13 1719 468 2.92 / 155.92 2 16
5 13 442.72 18 15.25 964 265 3.18 / 156.18 2 16
6 13 24.00 18 15.32 369 102 3.28 / 156.28 2 9
7 8 -0.08 165 15.27 332 836 4.12 / 157.12 2 12
Average= 3.93
(KJ/cycle)

Cycle 38 GMT 2/ 4/2024 7:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 32 15.22 499 243 0.24 / 148.93 2 5
2 7 1915.88 38 14.97 2849 1621 1.86 / 150.55 2 11
3 13 1704.52 18 14.99 2595 700 2.56 / 151.25 2 15
4 13 1140.36 18 15.07 1872 508 3.07 / 151.76 2 16
5 13 485.68 18 15.23 1023 280 3.35 / 152.04 2 16
6 13 37.60 18 15.31 398 110 3.46 / 152.15 2 9
7 8 0.08 165 15.28 338 852 4.31 / 153.00 2 17
Average= 3.92
(KJ/cycle)

Cycle 37 GMT 23/ 3/2024 9:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 32 15.23 485 236 0.24 / 144.68 2 5
2 7 1860.52 38 15.02 2777 1585 1.82 / 146.27 2 13
3 13 1517.80 18 15.05 2364 640 2.46 / 146.91 2 14
4 13 1051.12 18 15.13 1765 481 2.94 / 147.39 2 15
5 13 588.92 18 15.21 1169 320 3.26 / 147.71 2 17
6 13 60.96 18 15.32 437 121 3.38 / 147.83 2 16
7 8 0.20 165 15.28 340 857 4.24 / 148.69 2 17
Average= 3.91
(KJ/cycle)

Cycle 36 GMT 13/ 3/2024 12:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 32 15.23 501 244 0.24 / 140.23 2 4
2 7 1987.00 38 14.97 2946 1676 1.92 / 141.90 2 12
3 13 1730.00 18 15.00 2647 715 2.63 / 142.62 2 13
4 13 1104.20 18 15.11 1844 502 3.14 / 143.12 2 16
5 13 697.20 18 15.18 1319 360 3.50 / 143.48 2 16
6 13 37.28 18 15.32 403 111 3.61 / 143.59 2 4
7 8 0.08 165 15.27 340 857 4.46 / 144.45 2 13
Average= 3.90
(KJ/cycle)

Cycle 35 GMT 3/ 3/2024 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 32 15.24 501 244 0.24 / 135.86 2 5
2 7 1984.40 38 14.97 2936 1670 1.91 / 137.53 2 12
3 13 1525.80 18 15.03 2383 645 2.56 / 138.17 2 15
4 13 1377.60 18 15.03 2195 594 3.15 / 138.77 2 16
5 13 404.16 18 15.26 910 250 3.40 / 139.02 2 16
6 13 35.60 18 15.33 393 108 3.51 / 139.12 2 12
7 8 -0.04 165 15.29 340 858 4.37 / 139.98 2 17
Average= 3.89
(KJ/cycle)

Cycle 34 GMT 22/ 2/2024 16:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 32 15.23 503 245 0.25 / 131.50 2 5
2 7 1901.64 38 15.02 2843 1623 1.87 / 133.13 2 12
3 13 1648.16 18 15.03 2531 685 2.55 / 133.81 2 14
4 13 1057.00 18 15.14 1778 485 3.04 / 134.30 2 15
5 13 615.64 18 15.22 1199 328 3.37 / 134.62 2 17
6 13 76.80 18 15.32 463 128 3.49 / 134.75 2 12
7 8 0.00 165 15.29 341 860 4.35 / 135.61 2 8
Average= 3.87
(KJ/cycle)

Cycle 33 GMT 12/ 2/2024 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 32 15.24 483 236 0.24 / 127.01 2 5
2 7 2008.36 39 14.99 2974 1739 1.97 / 128.75 2 10
3 13 1810.00 18 15.01 2729 737 2.71 / 129.49 2 11
4 13 1075.84 18 15.11 1800 490 3.20 / 129.98 2 15
5 13 539.56 18 15.22 1096 300 3.50 / 130.28 2 16
6 13 38.20 18 15.32 397 109 3.61 / 130.39 2 11
7 8 0.20 165 15.28 346 872 4.48 / 131.26 2 15
Average= 3.86
(KJ/cycle)

Cycle 32 GMT 3/ 2/2024 0:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 32 15.23 503 245 0.25 / 122.65 2 4
2 7 2008.80 38 15.00 2976 1696 1.94 / 124.35 2 9
3 13 1573.68 18 15.06 2455 666 2.61 / 125.02 2 12
4 13 1199.60 18 15.09 1969 535 3.14 / 125.55 2 14
5 13 430.96 18 15.27 952 262 3.40 / 125.81 2 15
6 13 18.44 18 15.34 370 102 3.51 / 125.92 2 11
7 8 -0.08 165 15.29 341 860 4.37 / 126.78 2 5
Average= 3.84
(KJ/cycle)

Cycle 31 GMT 24/ 1/2024 4:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 32 15.23 498 243 0.24 / 118.41 2 5
2 7 1957.24 38 14.99 2905 1655 1.90 / 120.06 2 11
3 13 1396.40 18 15.08 2209 600 2.50 / 120.66 2 15
4 13 1041.72 18 15.13 1764 480 2.98 / 121.14 2 18
5 13 487.56 18 15.24 1035 284 3.26 / 121.43 2 17
6 13 38.20 18 15.34 399 110 3.37 / 121.54 2 17
7 8 0.08 165 15.29 346 873 4.24 / 122.41 2 9
Average= 3.83
(KJ/cycle)

Cycle 30 GMT 14/ 1/2024 7: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 32 15.24 502 245 0.24 / 114.04 2 5
2 7 2003.80 38 14.99 2967 1690 1.93 / 115.73 2 9
3 13 1491.08 18 15.06 2334 633 2.57 / 116.36 2 13
4 13 1031.96 18 15.14 1751 477 3.04 / 116.84 2 15
5 13 633.16 18 15.21 1227 336 3.38 / 117.18 2 17
6 13 36.68 18 15.33 399 110 3.49 / 117.29 2 9
7 8 0.08 165 15.29 348 878 4.37 / 118.17 2 16
Average= 3.81
(KJ/cycle)

Cycle 29 GMT 4/ 1/2024 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 32 15.26 509 249 0.25 / 109.69 2 5
2 7 2014.00 38 15.00 2969 1692 1.94 / 111.38 2 9
3 13 1592.04 18 15.06 2464 668 2.61 / 112.05 2 12
4 13 984.92 18 15.15 1687 460 3.07 / 112.51 2 17
5 13 595.36 18 15.23 1174 322 3.39 / 112.83 2 16
6 13 24.04 18 15.35 375 104 3.49 / 112.94 2 8
7 8 0.20 165 15.30 340 858 4.35 / 113.80 2 13
Average= 3.79
(KJ/cycle)

Cycle 28 GMT 25/12/2023 16:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 32 15.32 485 238 0.24 / 105.29 2 7
2 3 968.44 -1 15.64 0 0 0.00 / 105.29 2 7
3 7 2003.56 38 14.99 2952 1682 1.92 / 106.97 2 9
4 13 1632.28 18 15.04 2519 682 2.60 / 107.65 2 12
5 13 1226.04 18 15.08 2000 543 3.14 / 108.19 2 14
6 13 482.96 18 15.25 1024 281 3.43 / 108.47 2 16
7 13 18.00 18 15.34 373 103 3.53 / 108.58 2 10
8 8 0.04 165 15.29 344 868 4.40 / 109.44 2 13
Average= 3.77
(KJ/cycle)

Cycle 27 GMT 15/12/2023 22: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 32 15.27 505 247 0.25 / 101.69 2 6
2 7 1251.64 39 15.27 2008 1196 1.44 / 102.89 2 12
3 13 1251.64 18 15.24 2019 554 2.00 / 103.44 2 14
4 13 1210.12 18 15.20 1957 535 2.53 / 103.98 2 16
5 13 278.44 18 15.38 738 204 2.74 / 104.18 2 15
6 8 0.08 165 15.38 342 868 3.60 / 105.05 2 12
Average= 3.75
(KJ/cycle)

Cycle 26 GMT 6/12/2023 1:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 32 15.27 502 245 0.25 / 97.49 2 6
2 7 2005.64 38 15.01 2972 1695 1.94 / 99.18 2 10
3 13 1569.20 18 15.09 2440 663 2.60 / 99.84 2 14
4 13 1045.24 18 15.15 1760 480 3.08 / 100.32 2 16
5 13 397.40 18 15.28 910 250 3.33 / 100.57 2 16
6 8 0.04 165 15.32 344 870 4.20 / 101.44 2 3
Average= 3.76
(KJ/cycle)

Cycle 25 GMT 26/11/2023 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 32 15.28 489 239 0.24 / 93.08 2 3
2 7 2008.00 38 15.01 2959 1688 1.93 / 94.76 2 8
3 13 1463.64 18 15.09 2299 624 2.55 / 95.39 2 12
4 13 1307.68 18 15.09 2097 570 3.12 / 95.96 2 14
5 13 535.84 18 15.26 1093 300 3.42 / 96.26 2 17
6 13 25.64 18 15.35 385 106 3.53 / 96.36 2 4
7 8 0.12 165 15.32 347 877 4.40 / 97.24 2 13
Average= 3.74
(KJ/cycle)

Cycle 24 GMT 16/11/2023 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 32 15.29 499 244 0.24 / 88.78 2 8
2 7 2009.04 38 15.01 2979 1699 1.94 / 90.48 2 8
3 13 1623.12 18 15.05 2506 679 2.62 / 91.16 2 12
4 13 1162.56 18 15.11 1925 524 3.15 / 91.68 2 15
5 13 509.72 18 15.26 1056 290 3.44 / 91.97 2 16
6 8 0.16 165 15.32 341 862 4.30 / 92.84 2 11
Average= 3.71
(KJ/cycle)

Cycle 23 GMT 6/11/2023 15:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 32 15.27 518 253 0.25 / 84.72 2 5
2 3 1018.20 1 15.36 1766 27 0.28 / 84.74 2 10
3 7 1788.00 38 15.06 2695 1542 1.82 / 86.28 2 12
4 13 1638.60 18 15.08 2524 685 2.51 / 86.97 2 14
5 13 1000.48 18 15.18 1701 465 2.97 / 87.43 2 16
6 13 357.32 18 15.32 846 233 3.21 / 87.67 2 16
7 8 0.04 165 15.33 344 870 4.08 / 88.54 2 30
Average= 3.69
(KJ/cycle)

Cycle 22 GMT 27/10/2023 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 32 15.28 510 249 0.25 / 80.39 2 5
2 7 2011.84 38 15.00 2969 1692 1.94 / 82.09 2 9
3 13 1641.36 18 15.07 2520 684 2.63 / 82.77 2 12
4 13 1072.20 18 15.14 1805 492 3.12 / 83.26 2 15
5 13 626.20 18 15.24 1211 332 3.45 / 83.59 2 17
6 8 0.20 165 15.32 344 870 4.32 / 84.46 2 2
Average= 3.67
(KJ/cycle)

Cycle 21 GMT 17/10/2023 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 32 15.27 503 246 0.25 / 76.08 2 8
2 7 2013.56 38 15.02 2979 1700 1.95 / 77.78 2 9
3 13 1551.24 18 15.08 2419 657 2.60 / 78.44 2 13
4 13 1289.04 18 15.11 2080 566 3.17 / 79.00 2 15
5 13 436.88 18 15.29 958 264 3.43 / 79.27 2 16
6 8 0.08 165 15.34 346 876 4.31 / 80.14 2 11
Average= 3.64
(KJ/cycle)

Cycle 20 GMT 8/10/2023 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 32 15.29 512 251 0.25 / 71.78 2 5
2 7 2004.36 39 15.02 2967 1738 1.99 / 73.52 2 9
3 13 1578.68 18 15.08 2447 664 2.65 / 74.18 2 13
4 13 1036.80 18 15.16 1758 480 3.13 / 74.66 2 15
5 13 521.08 18 15.27 1077 296 3.43 / 74.96 2 17
6 8 0.12 165 15.34 346 876 4.30 / 75.84 2 20
Average= 3.61
(KJ/cycle)

Cycle 19 GMT 28/ 9/2023 7:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 32 15.29 503 246 0.25 / 67.62 2 6
2 3 976.96 -1 15.63 0 0 0.00 / 67.62 2 6
3 3 1034.56 1 15.38 1802 28 0.27 / 67.65 2 10
4 7 2008.04 38 15.02 2968 1694 1.97 / 69.35 2 10
5 13 1519.24 18 15.10 2370 644 2.61 / 69.99 2 13
6 13 927.80 18 15.19 1607 439 3.05 / 70.43 2 16
7 13 330.40 18 15.31 814 224 3.28 / 70.65 2 16
8 8 -0.08 165 15.33 347 878 4.15 / 71.53 2 7
Average= 3.58
(KJ/cycle)

Cycle 18 GMT 18/ 9/2023 11:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 32 15.30 508 249 0.25 / 63.46 2 6
2 7 1972.60 39 15.04 2927 1717 1.97 / 65.18 2 10
3 13 1543.20 18 15.10 2400 652 2.62 / 65.83 2 13
4 13 1005.28 18 15.17 1712 467 3.09 / 66.30 2 16
5 13 314.68 18 15.33 785 217 3.30 / 66.51 2 14
6 8 0.00 165 15.34 341 863 4.17 / 67.38 2 8
Average= 3.55
(KJ/cycle)

Cycle 17 GMT 8/ 9/2023 14:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 31 15.32 509 242 0.24 / 59.17 2 8
2 3 1018.04 1 15.39 1758 27 0.27 / 59.20 2 8
3 7 2001.76 38 15.04 2964 1694 1.96 / 60.89 2 10
4 13 1642.16 18 15.09 2536 689 2.65 / 61.58 2 13
5 13 979.96 18 15.19 1674 458 3.11 / 62.04 2 15
6 13 530.08 18 15.27 1079 297 3.41 / 62.34 2 15
7 8 0.16 165 15.35 346 876 4.28 / 63.21 2 11
Average= 3.51
(KJ/cycle)

Cycle 16 GMT 29/ 8/2023 16:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 31 15.30 500 237 0.24 / 54.95 2 7
2 7 1963.64 39 15.04 2912 1708 1.95 / 56.65 2 11
3 13 1502.12 18 15.11 2355 641 2.59 / 57.29 2 14
4 13 1045.48 18 15.18 1771 484 3.07 / 57.78 2 16
5 13 455.64 18 15.30 993 273 3.34 / 58.05 2 16
6 8 0.20 165 15.35 347 879 4.22 / 58.93 2 18
Average= 3.47
(KJ/cycle)

Cycle 15 GMT 19/ 8/2023 18:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 31 15.30 513 243 0.24 / 50.70 2 7
2 7 2003.12 39 15.04 2958 1735 1.98 / 52.43 2 9
3 13 1683.28 18 15.07 2577 699 2.68 / 53.13 2 12
4 13 932.04 18 15.21 1622 444 3.12 / 53.58 2 15
5 13 398.00 18 15.32 910 251 3.37 / 53.83 2 15
6 8 -0.04 165 15.34 348 881 4.25 / 54.71 2 18
Average= 3.42
(KJ/cycle)

Cycle 14 GMT 9/ 8/2023 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 31 15.31 507 241 0.24 / 46.52 2 6
2 3 1017.56 1 15.39 1766 27 0.27 / 46.55 2 9
3 7 2010.00 38 15.05 2956 1691 1.96 / 48.24 2 10
4 13 1518.28 18 15.12 2365 644 2.60 / 48.88 2 13
5 13 1000.52 18 15.19 1698 464 3.07 / 49.35 2 16
6 13 325.92 18 15.34 811 224 3.29 / 49.57 2 16
7 8 0.12 165 15.36 349 885 4.17 / 50.46 2 13
Average= 3.36
(KJ/cycle)

Cycle 13 GMT 31/ 7/2023 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 31 15.32 497 236 0.24 / 42.60 2 6
2 3 1018.96 1 15.42 1780 27 0.26 / 42.62 2 9
3 7 1668.00 38 15.14 2543 1463 1.73 / 44.09 2 12
4 13 1472.68 18 15.17 2310 631 2.36 / 44.72 2 13
5 13 1005.76 18 15.24 1704 467 2.82 / 45.19 2 16
6 13 335.20 18 15.35 823 227 3.05 / 45.41 2 15
7 8 0.20 165 15.37 342 867 3.92 / 46.28 2 10
Average= 3.31
(KJ/cycle)

Cycle 12 GMT 21/ 7/2023 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 30 15.31 497 228 0.23 / 38.56 2 7
2 3 1019.76 1 15.37 1769 27 0.26 / 38.58 2 8
3 7 1760.96 38 15.13 2652 1525 1.78 / 40.11 2 11
4 13 1514.32 18 15.16 2358 643 2.42 / 40.75 2 13
5 13 1018.24 18 15.23 1722 472 2.90 / 41.23 2 16
6 13 460.60 18 15.33 983 271 3.17 / 41.50 2 16
7 8 -0.20 165 15.37 341 865 4.03 / 42.36 2 12
Average= 3.26
(KJ/cycle)

Cycle 11 GMT 11/ 7/2023 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 30 15.38 489 226 0.23 / 34.20 2 5
2 7 1800.92 75 15.00 2694 3031 3.26 / 37.23 2 12
3 13 404.36 18 15.33 907 250 3.51 / 37.48 2 16
4 8 0.32 165 15.37 335 850 4.36 / 38.33 2 13
Average= 3.19
(KJ/cycle)

Cycle 10 GMT 1/ 7/2023 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 15.34 484 215 0.22 / 30.83 2 6
2 3 1027.72 1 15.39 1779 27 0.24 / 30.85 2 10
3 7 1297.16 74 15.22 2030 2286 2.53 / 33.14 2 13
4 8 0.16 165 15.44 327 833 3.36 / 33.97 2 7
Average= 3.09
(KJ/cycle)

Cycle 9 GMT 21/ 6/2023 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 29 15.40 488 218 0.22 / 26.85 2 6
2 7 1551.72 75 15.09 2373 2686 2.90 / 29.54 2 13
3 13 397.48 18 15.36 886 245 3.15 / 29.78 2 16
4 8 -0.12 165 15.39 326 828 3.98 / 30.61 2 8
Average= 3.06
(KJ/cycle)

Cycle 8 GMT 11/ 6/2023 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 30 15.37 474 219 0.22 / 23.69 2 6
2 7 1179.76 74 15.27 1885 2130 2.35 / 25.82 2 13
3 8 0.04 165 15.47 321 819 3.17 / 26.63 2 11
Average= 2.96
(KJ/cycle)

Cycle 7 GMT 1/ 6/2023 13:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 29 15.37 473 211 0.21 / 20.52 2 5
2 7 1191.84 74 15.25 1893 2136 2.35 / 22.66 2 12
3 8 0.00 165 15.42 318 809 3.16 / 23.47 2 10
Average= 2.93
(KJ/cycle)

Cycle 6 GMT 31/ 5/2023 13:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 29 15.36 464 207 0.21 / 17.32 2 5
2 3 1021.04 1 15.41 1765 27 0.23 / 17.35 2 9
3 7 1179.40 75 15.24 1871 2139 2.37 / 19.49 2 12
4 8 0.24 165 15.42 323 822 3.19 / 20.31 2 12
Average= 2.90
(KJ/cycle)

Cycle 5 GMT 30/ 5/2023 14:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 29 15.36 475 212 0.21 / 14.05 2 5
2 3 1018.72 1 15.43 1746 27 0.24 / 14.08 2 9
3 7 1271.84 74 15.20 1993 2242 2.48 / 16.32 2 12
4 8 0.08 165 15.41 312 793 3.27 / 17.12 2 12
Average= 2.85
(KJ/cycle)

Cycle 4 GMT 29/ 5/2023 14:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 29 15.36 468 208 0.21 / 11.02 2 4
2 3 1024.00 1 15.40 1768 27 0.24 / 11.05 2 9
3 7 1084.64 75 15.27 1742 1995 2.23 / 13.04 2 13
4 8 0.00 165 15.43 315 802 3.03 / 13.84 2 15
Average= 2.77
(KJ/cycle)

Cycle 3 GMT 28/ 5/2023 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 27 15.39 477 198 0.20 / 7.79 2 5
2 10 1011.76 2 15.36 1738 53 0.25 / 7.85 2 7
3 7 1215.52 74 15.24 1919 2164 2.42 / 10.01 2 12
4 8 0.04 165 15.42 314 799 3.21 / 10.81 2 8
Average= 2.70
(KJ/cycle)

Cycle 2 GMT 27/ 5/2023 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 33 15.34 464 235 0.23 / 4.90 2 4
2 3 869.12 -2 15.68 0 0 0.00 / 4.90 2 4
3 3 904.36 -2 15.72 0 0 0.00 / 4.90 2 4
4 7 1015.00 74 15.30 1664 1884 2.12 / 6.78 2 13
5 8 -0.08 165 15.45 320 816 2.93 / 7.60 2 10
Average= 2.53
(KJ/cycle)

Cycle 1 GMT 26/ 5/2023 17: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 28 15.52 435 189 0.19 / 1.92 2 3
2 3 1059.12 2 15.40 1815 56 0.24 / 1.98 2 8
3 7 1013.52 74 15.25 1663 1877 2.12 / 3.85 2 13
4 8 -0.04 165 15.40 318 808 2.93 / 4.66 2 15
Average= 2.33
(KJ/cycle)

Cycle 0 GMT 26/ 5/2023 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 27 15.66 426 180 0.18 / 0.18 2 3
2 7 132.40 74 15.62 455 526 0.71 / 0.71 2 4
3 8 0.16 240 15.59 274 1025 1.73 / 1.73 2 16
Average= 1.73