SIO Argo Site:
Pump Diagnostics Page   



Serial= 6043 WMO= 5905757

Return

←PreviousNext→

Cycle 357 GMT 22/ 7/2020 22:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.0 561 15.34 279 2401 2.40 / 1968.60 244 244
2 6 -99.0 55 15.28 299 251 2.65 / 1968.86 244 244
3 7 -99.0 80 15.29 307 376 3.03 / 1969.23 244 244
4 13 -99.0 80 15.27 306 374 3.40 / 1969.61 244 244
5 13 -99.0 80 15.25 307 375 3.78 / 1969.98 244 244
6 13 -99.0 80 15.23 306 373 4.15 / 1970.35 244 244
7 13 -99.0 80 15.22 298 363 4.51 / 1970.72 244 244
8 13 -99.0 80 15.20 299 364 4.88 / 1971.08 244 244
9 13 -99.0 80 15.19 298 362 5.24 / 1971.44 244 244
10 13 -99.0 80 15.18 291 353 5.59 / 1971.79 244 244
11 13 -99.0 80 15.17 294 357 5.95 / 1972.15 244 244
12 13 -99.0 80 15.17 294 357 6.30 / 1972.51 244 244
13 13 -99.0 80 15.16 291 353 6.66 / 1972.86 244 244
14 13 -99.0 80 15.16 289 350 7.01 / 1973.21 244 244
15 13 -99.0 80 15.16 290 352 7.36 / 1973.56 244 244
16 13 -99.0 80 15.16 287 348 7.71 / 1973.91 244 244
17 13 -99.0 80 15.16 285 346 8.05 / 1974.26 244 244
18 13 -99.0 80 15.16 287 348 8.40 / 1974.61 244 244
19 13 -99.0 80 15.16 289 350 8.75 / 1974.96 244 244
20 13 -99.0 80 15.16 290 352 9.10 / 1975.31 244 244
21 13 -99.0 80 15.16 284 344 9.45 / 1975.65 244 244
22 13 -99.0 80 15.16 282 342 9.79 / 1975.99 244 244
23 14 -99.0 1 15.17 294 4 9.79 / 1976.00 244 244
24 14 -99.0 9 15.17 287 39 9.83 / 1976.04 244 244
Average= 1976.04
(KJ/cycle)

Cycle 350 GMT 20/ 7/2020 16:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.0 561 15.35 275 2368 2.37 / 1958.77 244 244
2 6 -99.0 55 15.29 294 247 2.62 / 1959.02 244 244
3 7 -99.0 80 15.30 304 372 2.99 / 1959.39 244 244
4 13 -99.0 80 15.29 305 373 3.36 / 1959.77 244 244
5 13 -99.0 80 15.27 296 362 3.72 / 1960.13 244 244
6 13 -99.0 80 15.25 294 359 4.08 / 1960.49 244 244
7 13 -99.0 80 15.24 292 356 4.44 / 1960.84 244 244
8 13 -99.0 80 15.22 294 358 4.79 / 1961.20 244 244
9 13 -99.0 80 15.21 291 354 5.15 / 1961.56 244 244
10 13 -99.0 80 15.20 289 351 5.50 / 1961.91 244 244
11 13 -99.0 80 15.19 290 352 5.85 / 1962.26 244 244
12 13 -99.0 80 15.18 295 358 6.21 / 1962.62 244 244
13 13 -99.0 80 15.18 291 353 6.56 / 1962.97 244 244
14 13 -99.0 80 15.18 290 352 6.92 / 1963.32 244 244
15 13 -99.0 80 15.18 290 352 7.27 / 1963.68 244 244
16 13 -99.0 80 15.18 288 350 7.62 / 1964.03 244 244
17 13 -99.0 80 15.17 295 358 7.98 / 1964.38 244 244
18 13 -99.0 80 15.17 298 362 8.34 / 1964.74 244 244
19 13 -99.0 80 15.17 292 354 8.69 / 1965.10 244 244
20 13 -99.0 80 15.17 295 358 9.05 / 1965.46 244 244
21 13 -99.0 80 15.18 289 351 9.40 / 1965.81 244 244
22 13 -99.0 80 15.18 289 351 9.75 / 1966.16 244 244
23 14 -99.0 1 15.18 305 5 9.76 / 1966.16 244 244
24 14 -99.0 9 15.18 291 40 9.80 / 1966.20 244 244
Average= 1966.20
(KJ/cycle)

Cycle 346 GMT 18/ 7/2020 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.0 561 15.26 300 2568 2.57 / 1949.03 2 244
2 6 -99.0 55 15.22 306 256 2.82 / 1949.29 244 244
3 7 -99.0 80 15.36 307 377 3.20 / 1949.67 244 244
4 13 -99.0 80 15.34 300 368 3.57 / 1950.04 244 244
5 13 -99.0 80 15.33 296 363 3.93 / 1950.40 244 244
6 13 -99.0 80 15.31 294 360 4.29 / 1950.76 244 244
7 13 -99.0 80 15.29 293 358 4.65 / 1951.12 244 244
8 13 -99.0 80 15.28 291 356 5.01 / 1951.47 244 244
9 13 -99.0 80 15.26 290 354 5.36 / 1951.83 244 244
10 13 -99.0 80 15.24 290 354 5.71 / 1952.18 244 244
11 13 -99.0 80 15.23 286 348 6.06 / 1952.53 244 244
12 13 -99.0 80 15.22 285 347 6.41 / 1952.88 244 244
13 13 -99.0 80 15.21 284 346 6.76 / 1953.22 244 244
14 13 -99.0 80 15.21 288 350 7.11 / 1953.57 244 244
15 13 -99.0 80 15.20 289 351 7.46 / 1953.92 244 244
16 13 -99.0 80 15.19 291 354 7.81 / 1954.28 244 244
17 13 -99.0 80 15.19 289 351 8.16 / 1954.63 244 244
18 13 -99.0 80 15.19 293 356 8.52 / 1954.99 244 244
19 13 -99.0 80 15.19 286 348 8.87 / 1955.33 244 244
20 13 -99.0 80 15.19 284 345 9.21 / 1955.68 244 244
21 13 -99.0 80 15.19 281 341 9.55 / 1956.02 244 244
22 13 -99.0 80 15.19 283 344 9.90 / 1956.36 244 244
23 14 -99.0 1 15.19 293 4 9.90 / 1956.37 244 244
24 14 -99.0 9 15.19 287 39 9.94 / 1956.41 244 244
Average= 33.73
(KJ/cycle)

Cycle 345 GMT 17/ 7/2020 8:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 356 436 0.44 / 1946.21 2 38
2 14 -0.2 48 15.28 355 260 0.70 / 1946.47 2 106
Average= 34.15
(KJ/cycle)

Cycle 344 GMT 16/ 7/2020 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 356 436 0.44 / 1945.51 2 39
2 14 0.0 48 15.28 352 258 0.69 / 1945.77 2 108
Average= 34.75
(KJ/cycle)

Cycle 343 GMT 16/ 7/2020 13:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 364 446 0.45 / 1944.80 2 33
2 14 0.0 50 15.28 359 274 0.72 / 1945.08 2 104
Average= 35.37
(KJ/cycle)

Cycle 342 GMT 16/ 7/2020 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 358 438 0.44 / 1944.11 2 34
2 14 -0.1 45 15.29 358 246 0.68 / 1944.36 2 108
Average= 36.01
(KJ/cycle)

Cycle 341 GMT 15/ 7/2020 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 365 447 0.45 / 1943.41 2 43
2 14 -0.1 48 15.28 361 265 0.71 / 1943.67 2 109
Average= 36.67
(KJ/cycle)

Cycle 340 GMT 15/ 7/2020 9: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.31 357 437 0.44 / 1942.64 2 27
2 14 0.0 58 15.29 359 318 0.76 / 1942.96 2 110
Average= 37.36
(KJ/cycle)

Cycle 339 GMT 14/ 7/2020 23:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 358 438 0.44 / 1941.94 2 41
2 14 -0.1 48 15.29 356 261 0.70 / 1942.21 2 112
Average= 38.08
(KJ/cycle)

Cycle 338 GMT 14/ 7/2020 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 367 450 0.45 / 1941.15 2 36
2 14 0.0 65 15.28 354 352 0.80 / 1941.51 2 129
Average= 38.83
(KJ/cycle)

Cycle 337 GMT 14/ 7/2020 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 359 440 0.44 / 1940.42 2 36
2 14 0.0 52 15.29 353 281 0.72 / 1940.70 2 116
Average= 39.61
(KJ/cycle)

Cycle 336 GMT 13/ 7/2020 19:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 361 442 0.44 / 1939.74 2 41
2 14 0.0 45 15.29 361 248 0.69 / 1939.98 2 109
Average= 40.42
(KJ/cycle)

Cycle 335 GMT 13/ 7/2020 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 357 437 0.44 / 1939.03 2 40
2 14 0.0 48 15.29 355 261 0.70 / 1939.29 2 109
Average= 41.26
(KJ/cycle)

Cycle 334 GMT 13/ 7/2020 0:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 354 434 0.43 / 1938.33 2 29
2 14 -0.1 50 15.29 346 265 0.70 / 1938.60 2 114
Average= 42.14
(KJ/cycle)

Cycle 333 GMT 12/ 7/2020 14:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 355 435 0.44 / 1937.68 2 32
2 14 0.0 39 15.30 357 213 0.65 / 1937.90 3 108
Average= 43.06
(KJ/cycle)

Cycle 332 GMT 12/ 7/2020 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.35 359 441 0.44 / 1936.98 2 43
2 14 0.0 50 15.33 352 270 0.71 / 1937.25 2 104
Average= 44.03
(KJ/cycle)

Cycle 331 GMT 11/ 7/2020 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.39 355 437 0.44 / 1936.20 2 32
2 14 0.0 63 15.37 350 339 0.78 / 1936.54 2 112
Average= 45.04
(KJ/cycle)

Cycle 330 GMT 11/ 7/2020 10:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.42 359 443 0.44 / 1935.39 2 38
2 14 0.0 69 15.40 351 373 0.82 / 1935.76 2 105
Average= 46.09
(KJ/cycle)

Cycle 329 GMT 11/ 7/2020 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.46 363 449 0.45 / 1934.52 2 31
2 14 -0.1 78 15.44 353 425 0.87 / 1934.95 2 111
Average= 47.19
(KJ/cycle)

Cycle 328 GMT 10/ 7/2020 15:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.4 80 15.46 370 458 0.46 / 1933.50 2 42
2 14 0.4 103 15.43 363 577 1.03 / 1934.07 2 123
Average= 48.35
(KJ/cycle)

Cycle 327 GMT 10/ 7/2020 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 504.7 494 14.30 3112 21984 21.98 / 1921.10 2 66
2 6 4466.4 63 13.80 3115 2708 24.69 / 1923.80 2 68
3 3 3509.4 90 14.58 2607 3421 28.11 / 1927.22 2 78
4 3 2315.6 88 14.82 1917 2500 30.61 / 1929.72 2 82
5 7 1038.6 80 15.08 1133 1367 31.98 / 1931.09 2 79
6 13 938.7 80 15.04 1047 1260 33.24 / 1932.35 2 73
7 13 127.5 80 15.18 511 621 33.86 / 1932.97 2 162
8 14 -0.2 3 15.21 440 20 33.88 / 1932.99 23 150
9 14 -0.2 7 15.20 439 47 33.93 / 1933.04 73 244
Average= 49.57
(KJ/cycle)

Cycle 326 GMT 9/ 7/2020 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 410.8 492 15.16 641 4781 4.78 / 1894.22 2 32
2 6 516.0 57 15.03 682 584 5.37 / 1894.81 2 37
3 3 1305.8 36 15.13 1282 698 6.06 / 1895.51 2 60
4 3 1021.5 21 15.18 1149 366 6.43 / 1895.87 2 64
5 7 678.9 80 15.21 907 1104 7.53 / 1896.98 2 63
6 13 595.0 80 15.17 830 1007 8.54 / 1897.98 2 51
7 13 74.7 80 15.21 482 586 9.13 / 1898.57 2 60
8 13 41.1 80 15.20 399 485 9.61 / 1899.05 2 244
9 14 -0.4 1 15.20 399 6 9.62 / 1899.06 244 244
10 14 -0.3 9 15.20 370 51 9.67 / 1899.11 244 244
Average= 49.98
(KJ/cycle)

Cycle 325 GMT 8/ 7/2020 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 367 449 0.45 / 1889.32 2 37
2 14 0.0 22 15.29 368 124 0.57 / 1889.44 2 122
Average= 51.07
(KJ/cycle)

Cycle 324 GMT 7/ 7/2020 20: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 376 460 0.46 / 1888.75 2 46
2 14 0.0 22 15.29 366 123 0.58 / 1888.87 2 115
Average= 52.47
(KJ/cycle)

Cycle 323 GMT 7/ 7/2020 10:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.4 80 15.30 377 461 0.46 / 1888.12 2 27
2 14 0.0 30 15.29 368 169 0.63 / 1888.29 2 115
Average= 53.95
(KJ/cycle)

Cycle 322 GMT 7/ 7/2020 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 372 456 0.46 / 1887.53 2 34
2 14 0.0 22 15.29 373 125 0.58 / 1887.66 2 102
Average= 55.52
(KJ/cycle)

Cycle 321 GMT 6/ 7/2020 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 383 469 0.47 / 1886.84 2 35
2 14 0.0 41 15.29 374 234 0.70 / 1887.07 2 114
Average= 57.18
(KJ/cycle)

Cycle 320 GMT 6/ 7/2020 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.4 80 15.31 373 457 0.46 / 1886.06 2 33
2 14 0.5 54 15.28 378 312 0.77 / 1886.37 2 105
Average= 58.95
(KJ/cycle)

Cycle 319 GMT 5/ 7/2020 20:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.2 80 15.31 369 452 0.45 / 1885.29 2 33
2 14 -0.1 56 15.28 365 312 0.76 / 1885.60 2 125
Average= 60.83
(KJ/cycle)

Cycle 318 GMT 5/ 7/2020 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.30 373 457 0.46 / 1884.61 2 30
2 14 -0.1 41 15.29 364 228 0.68 / 1884.84 2 105
Average= 62.83
(KJ/cycle)

Cycle 317 GMT 5/ 7/2020 1:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 364 446 0.45 / 1883.94 2 29
2 14 0.1 39 15.29 364 217 0.66 / 1884.15 2 106
Average= 64.97
(KJ/cycle)

Cycle 316 GMT 4/ 7/2020 16:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 376 461 0.46 / 1883.29 2 38
2 14 0.0 35 15.29 373 200 0.66 / 1883.49 2 104
Average= 67.27
(KJ/cycle)

Cycle 315 GMT 4/ 7/2020 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 377 462 0.46 / 1882.68 2 38
2 14 -0.1 26 15.29 375 149 0.61 / 1882.83 2 126
Average= 69.73
(KJ/cycle)

Cycle 314 GMT 3/ 7/2020 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 372 455 0.46 / 1882.05 2 38
2 14 0.1 30 15.29 367 168 0.62 / 1882.22 3 110
Average= 72.39
(KJ/cycle)

Cycle 313 GMT 3/ 7/2020 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 378 463 0.46 / 1881.45 2 31
2 14 0.0 26 15.29 374 149 0.61 / 1881.60 2 122
Average= 75.26
(KJ/cycle)

Cycle 312 GMT 3/ 7/2020 2:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.31 372 456 0.46 / 1880.84 2 39
2 14 -0.1 26 15.29 374 149 0.60 / 1880.98 2 124
Average= 78.37
(KJ/cycle)

Cycle 311 GMT 2/ 7/2020 16:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.30 380 465 0.47 / 1880.25 2 41
2 14 0.1 22 15.29 383 129 0.59 / 1880.38 3 112
Average= 81.76
(KJ/cycle)

Cycle 310 GMT 2/ 7/2020 7:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 374 458 0.46 / 1879.66 2 47
2 14 -0.1 22 15.29 375 126 0.58 / 1879.79 2 122
Average= 85.44
(KJ/cycle)

Cycle 309 GMT 1/ 7/2020 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 383 469 0.47 / 1879.09 2 34
2 14 0.1 20 15.29 376 115 0.58 / 1879.20 2 121
Average= 89.49
(KJ/cycle)

Cycle 308 GMT 1/ 7/2020 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 389 476 0.48 / 1878.54 2 48
2 14 0.0 13 15.29 392 78 0.55 / 1878.62 2 117
Average= 93.93
(KJ/cycle)

Cycle 307 GMT 1/ 7/2020 3: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 384 470 0.47 / 1877.96 2 36
2 14 0.0 18 15.30 386 106 0.58 / 1878.06 3 113
Average= 98.85
(KJ/cycle)

Cycle 306 GMT 30/ 6/2020 17:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 375 459 0.46 / 1877.28 2 36
2 14 0.0 35 15.29 386 207 0.67 / 1877.49 2 115
Average= 104.30
(KJ/cycle)

Cycle 305 GMT 30/ 6/2020 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 380 465 0.47 / 1876.65 2 37
2 14 -0.1 30 15.29 383 176 0.64 / 1876.82 2 106
Average= 110.40
(KJ/cycle)

Cycle 304 GMT 29/ 6/2020 22:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 372 455 0.46 / 1875.99 2 32
2 14 -0.1 33 15.29 374 189 0.64 / 1876.18 2 110
Average= 117.26
(KJ/cycle)

Cycle 303 GMT 29/ 6/2020 13: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 379 464 0.46 / 1875.34 2 41
2 14 -0.1 35 15.29 372 199 0.66 / 1875.54 2 111
Average= 125.04
(KJ/cycle)

Cycle 302 GMT 29/ 6/2020 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 381 467 0.47 / 1874.66 2 36
2 14 0.0 37 15.29 369 209 0.68 / 1874.87 2 113
Average= 133.92
(KJ/cycle)

Cycle 301 GMT 28/ 6/2020 18:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 388 475 0.47 / 1874.03 2 38
2 14 -0.1 30 15.29 370 170 0.64 / 1874.20 2 122
Average= 144.17
(KJ/cycle)

Cycle 300 GMT 28/ 6/2020 8:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 377 462 0.46 / 1873.42 2 44
2 14 0.0 22 15.29 385 130 0.59 / 1873.55 2 135
Average= 156.13
(KJ/cycle)

Cycle 299 GMT 27/ 6/2020 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 374 458 0.46 / 1872.83 2 32
2 14 0.0 24 15.29 371 136 0.59 / 1872.96 2 120
Average= 170.27
(KJ/cycle)

Cycle 298 GMT 27/ 6/2020 13:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 384 470 0.47 / 1872.20 2 43
2 14 -0.1 28 15.29 381 163 0.63 / 1872.37 2 113
Average= 187.24
(KJ/cycle)

Cycle 297 GMT 27/ 6/2020 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 377 462 0.46 / 1871.62 2 41
2 14 -0.1 20 15.29 380 116 0.58 / 1871.73 2 111
Average= 207.97
(KJ/cycle)

Cycle 296 GMT 26/ 6/2020 18:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 379 464 0.46 / 1870.99 2 36
2 14 -0.1 28 15.29 379 162 0.63 / 1871.16 2 138
Average= 233.89
(KJ/cycle)

Cycle 295 GMT 26/ 6/2020 9:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 386 472 0.47 / 1870.42 2 49
2 14 0.0 18 15.29 388 107 0.58 / 1870.53 2 115
Average= 267.22
(KJ/cycle)

Cycle 294 GMT 25/ 6/2020 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 377 462 0.46 / 1869.79 2 28
2 14 -0.1 28 15.29 374 160 0.62 / 1869.95 2 110
Average= 311.66
(KJ/cycle)

Cycle 293 GMT 25/ 6/2020 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 378 463 0.46 / 1869.17 2 43
2 14 -0.2 28 15.29 374 160 0.62 / 1869.33 2 114
Average= 373.87
(KJ/cycle)

Cycle 292 GMT 25/ 6/2020 4:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 380 465 0.47 / 1868.51 2 41
2 14 -0.1 33 15.29 382 193 0.66 / 1868.71 2 110
Average= 467.18
(KJ/cycle)

Cycle 291 GMT 24/ 6/2020 19:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 383 469 0.47 / 1867.90 2 39
2 14 0.0 24 15.29 390 143 0.61 / 1868.05 2 106
Average= 622.68
(KJ/cycle)

Cycle 290 GMT 24/ 6/2020 9:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 380 465 0.47 / 1867.26 2 32
2 14 0.0 30 15.29 372 171 0.64 / 1867.44 2 130
Average= 933.72
(KJ/cycle)

Cycle 289 GMT 24/ 6/2020 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 377 462 0.46 / 1866.65 2 32
2 14 0.0 26 15.30 383 152 0.61 / 1866.80 2 101
Average= 1866.80
(KJ/cycle)

Cycle 285 GMT 23/ 6/2020 12:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 375 459 0.46 / 1866.09 2 42
2 14 -0.1 16 15.30 376 92 0.55 / 1866.19 2 113
Average= 207.35
(KJ/cycle)

Cycle 284 GMT 23/ 6/2020 3: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 371 454 0.45 / 1865.52 2 39
2 14 0.0 20 15.29 368 113 0.57 / 1865.63 2 109
Average= 233.20
(KJ/cycle)

Cycle 283 GMT 22/ 6/2020 17:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 382 468 0.47 / 1864.99 2 50
2 14 0.0 13 15.29 381 76 0.54 / 1865.07 2 123
Average= 266.44
(KJ/cycle)

Cycle 282 GMT 22/ 6/2020 8: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 383 469 0.47 / 1864.29 2 32
2 14 0.0 41 15.29 376 236 0.70 / 1864.52 2 118
Average= 310.75
(KJ/cycle)

Cycle 281 GMT 21/ 6/2020 13:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.34 369 453 0.45 / 1863.31 2 33
2 14 -0.1 30 15.33 373 172 0.62 / 1863.48 2 115
3 14 0.0 70 15.31 315 338 0.96 / 1863.82 35 244
Average= 372.76
(KJ/cycle)

Cycle 280 GMT 20/ 6/2020 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.39 376 463 0.46 / 1862.36 2 35
2 14 0.0 22 15.38 373 126 0.59 / 1862.48 2 126
3 14 0.0 78 15.37 312 374 0.96 / 1862.86 45 244
Average= 465.71
(KJ/cycle)

Cycle 279 GMT 20/ 6/2020 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.7 80 15.44 374 462 0.46 / 1861.38 2 25
2 14 0.7 28 15.43 377 163 0.62 / 1861.55 2 113
3 14 0.6 72 15.42 313 348 0.97 / 1861.89 29 244
Average= 620.63
(KJ/cycle)

Cycle 278 GMT 19/ 6/2020 6:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.0 461 14.71 2152 14593 14.59 / 1854.65 2 59
2 6 2814.8 60 14.35 2155 1855 16.45 / 1856.50 2 58
3 3 1835.3 64 14.89 1655 1577 18.03 / 1858.08 2 77
4 3 900.7 15 15.13 1102 250 18.28 / 1858.33 2 68
5 7 291.9 80 15.29 628 768 19.04 / 1859.10 2 57
6 13 196.1 80 15.27 556 679 19.72 / 1859.78 2 59
7 13 35.1 80 15.27 441 539 20.26 / 1860.32 2 45
8 14 0.0 67 15.25 412 421 20.68 / 1860.74 2 121
9 14 -0.1 33 15.24 365 184 20.87 / 1860.92 33 244
Average= 930.46
(KJ/cycle)

Cycle 277 GMT 17/ 6/2020 22: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.0 451 15.12 854 5824 5.82 / 1835.54 2 43
2 6 823.2 56 14.97 870 729 6.55 / 1836.27 2 44
3 3 1042.5 22 15.15 1129 376 6.93 / 1836.65 2 67
4 3 700.3 5 15.25 951 73 7.00 / 1836.72 2 66
5 7 593.9 80 15.25 821 1002 8.00 / 1837.72 2 65
6 13 511.7 80 15.21 752 915 8.92 / 1838.64 2 60
7 13 406.0 80 15.18 664 806 9.72 / 1839.44 2 60
8 14 -1.3 88 15.21 403 539 10.26 / 1839.98 2 102
9 14 -1.5 12 15.19 392 71 10.34 / 1840.06 37 244
Average= 1840.06
(KJ/cycle)

Cycle 274 GMT 16/ 6/2020 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 363 445 0.44 / 1828.73 2 31
2 14 0.0 187 15.28 348 994 1.44 / 1829.72 2 105
Average= 11.02
(KJ/cycle)

Cycle 273 GMT 15/ 6/2020 18:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 366 449 0.45 / 1827.21 2 29
2 14 -0.1 200 15.28 350 1070 1.52 / 1828.28 2 120
Average= 11.08
(KJ/cycle)

Cycle 272 GMT 15/ 6/2020 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 353 433 0.43 / 1825.80 2 30
2 14 -0.1 183 15.28 343 959 1.39 / 1826.76 2 115
Average= 11.14
(KJ/cycle)

Cycle 271 GMT 14/ 6/2020 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 368 451 0.45 / 1824.43 2 31
2 14 0.1 179 15.28 344 941 1.39 / 1825.37 2 129
Average= 11.20
(KJ/cycle)

Cycle 270 GMT 13/ 6/2020 11: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.3 80 15.32 376 461 0.46 / 1823.09 2 28
2 14 0.1 165 15.28 351 885 1.35 / 1823.98 2 131
Average= 11.26
(KJ/cycle)

Cycle 269 GMT 12/ 6/2020 16:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 365 447 0.45 / 1821.79 2 29
2 14 -0.1 157 15.29 353 847 1.29 / 1822.63 2 114
Average= 11.32
(KJ/cycle)

Cycle 268 GMT 11/ 6/2020 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 366 449 0.45 / 1820.20 2 32
2 14 0.0 213 15.28 349 1136 1.58 / 1821.34 2 107
Average= 11.38
(KJ/cycle)

Cycle 267 GMT 11/ 6/2020 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 367 450 0.45 / 1818.96 2 26
2 14 0.0 148 15.29 349 790 1.24 / 1819.75 2 117
Average= 11.44
(KJ/cycle)

Cycle 266 GMT 10/ 6/2020 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 371 455 0.45 / 1817.75 2 30
2 14 0.1 140 15.29 359 768 1.22 / 1818.51 2 122
Average= 11.51
(KJ/cycle)

Cycle 265 GMT 9/ 6/2020 14:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 367 450 0.45 / 1816.58 2 34
2 14 0.0 133 15.29 351 714 1.16 / 1817.29 2 104
Average= 11.58
(KJ/cycle)

Cycle 264 GMT 8/ 6/2020 20:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 367 450 0.45 / 1815.38 2 35
2 14 0.0 138 15.28 353 744 1.19 / 1816.13 2 122
Average= 11.64
(KJ/cycle)

Cycle 263 GMT 8/ 6/2020 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.32 357 438 0.44 / 1814.31 2 29
2 14 0.1 118 15.29 348 628 1.07 / 1814.93 2 101
Average= 11.71
(KJ/cycle)

Cycle 262 GMT 7/ 6/2020 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 369 452 0.45 / 1813.16 2 33
2 14 0.0 133 15.29 349 710 1.16 / 1813.87 2 131
Average= 11.78
(KJ/cycle)

Cycle 261 GMT 6/ 6/2020 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 366 449 0.45 / 1812.05 2 31
2 14 0.0 120 15.29 356 653 1.10 / 1812.71 2 110
Average= 11.85
(KJ/cycle)

Cycle 260 GMT 5/ 6/2020 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 365 447 0.45 / 1811.07 2 37
2 14 -0.1 73 15.30 353 394 0.84 / 1811.47 2 109
3 14 0.0 27 15.28 329 136 0.98 / 1811.60 31 244
Average= 11.92
(KJ/cycle)

Cycle 259 GMT 4/ 6/2020 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 361 442 0.44 / 1810.09 2 34
2 14 -0.1 88 15.29 350 471 0.91 / 1810.56 2 120
3 14 0.0 12 15.28 339 62 0.98 / 1810.63 49 244
Average= 11.99
(KJ/cycle)

Cycle 258 GMT 4/ 6/2020 5:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 367 450 0.45 / 1809.11 2 27
2 14 0.0 84 15.29 357 459 0.91 / 1809.57 2 119
3 14 0.0 16 15.28 336 82 0.99 / 1809.65 44 244
Average= 12.06
(KJ/cycle)

Cycle 257 GMT 3/ 6/2020 11: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 376 461 0.46 / 1808.02 2 37
2 14 -0.1 118 15.29 356 642 1.10 / 1808.66 2 108
Average= 12.14
(KJ/cycle)

Cycle 256 GMT 2/ 6/2020 16:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 376 461 0.46 / 1807.05 2 39
2 14 -0.1 45 15.30 359 247 0.71 / 1807.30 2 117
3 14 -0.1 55 15.29 309 260 0.97 / 1807.56 45 244
Average= 12.21
(KJ/cycle)

Cycle 255 GMT 1/ 6/2020 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 366 449 0.45 / 1806.04 2 28
2 14 -0.1 103 15.29 352 554 1.00 / 1806.59 2 105
Average= 12.29
(KJ/cycle)

Cycle 254 GMT 1/ 6/2020 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.8 80 15.33 363 445 0.45 / 1804.76 2 33
2 14 -0.1 155 15.29 349 827 1.27 / 1805.59 2 106
Average= 12.37
(KJ/cycle)

Cycle 253 GMT 31/ 5/2020 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.32 361 442 0.44 / 1803.13 2 35
2 14 0.0 223 15.28 348 1186 1.63 / 1804.31 2 134
Average= 12.44
(KJ/cycle)

Cycle 252 GMT 30/ 5/2020 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 368 451 0.45 / 1801.75 2 27
2 14 0.0 176 15.29 348 936 1.39 / 1802.69 2 106
Average= 12.52
(KJ/cycle)

Cycle 251 GMT 29/ 5/2020 20:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 363 445 0.44 / 1800.34 2 27
2 14 0.1 178 15.29 352 958 1.40 / 1801.30 2 125
Average= 12.60
(KJ/cycle)

Cycle 250 GMT 29/ 5/2020 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 365 447 0.45 / 1799.04 2 33
2 14 0.0 165 15.29 341 860 1.31 / 1799.90 2 103
Average= 12.68
(KJ/cycle)

Cycle 249 GMT 28/ 5/2020 7:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 366 449 0.45 / 1797.94 2 28
2 14 -0.1 120 15.29 354 650 1.10 / 1798.59 2 118
Average= 12.76
(KJ/cycle)

Cycle 248 GMT 27/ 5/2020 12:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 371 455 0.45 / 1796.82 2 34
2 14 0.0 125 15.29 353 675 1.13 / 1797.49 2 104
Average= 12.84
(KJ/cycle)

Cycle 247 GMT 26/ 5/2020 18:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 375 460 0.46 / 1795.82 2 25
2 14 -0.1 99 15.30 354 536 1.00 / 1796.36 2 115
3 14 -0.1 1 15.29 364 6 1.00 / 1796.36 50 117
Average= 12.92
(KJ/cycle)

Cycle 246 GMT 25/ 5/2020 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 374 458 0.46 / 1794.77 2 39
2 14 0.0 110 15.30 353 594 1.05 / 1795.36 2 113
Average= 13.01
(KJ/cycle)

Cycle 245 GMT 25/ 5/2020 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 369 452 0.45 / 1793.75 2 28
2 14 0.0 101 15.30 358 553 1.01 / 1794.31 2 111
Average= 13.10
(KJ/cycle)

Cycle 244 GMT 24/ 5/2020 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.33 367 450 0.45 / 1792.67 2 28
2 14 0.0 114 15.29 361 629 1.08 / 1793.30 2 108
Average= 13.19
(KJ/cycle)

Cycle 243 GMT 23/ 5/2020 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 373 457 0.46 / 1791.62 2 29
2 14 -0.1 110 15.29 355 597 1.05 / 1792.22 2 104
Average= 13.28
(KJ/cycle)

Cycle 242 GMT 22/ 5/2020 22: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.33 367 450 0.45 / 1790.54 2 33
2 14 0.1 114 15.30 359 626 1.08 / 1791.17 2 126
Average= 13.37
(KJ/cycle)

Cycle 241 GMT 22/ 5/2020 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.33 368 451 0.45 / 1789.29 2 26
2 14 -0.1 147 15.29 355 798 1.25 / 1790.09 2 126
Average= 13.46
(KJ/cycle)

Cycle 240 GMT 21/ 5/2020 13:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.34 363 445 0.45 / 1788.19 2 25
2 14 -0.1 120 15.31 355 652 1.10 / 1788.84 2 121
Average= 13.55
(KJ/cycle)

Cycle 239 GMT 20/ 5/2020 23: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.33 357 438 0.44 / 1787.19 2 29
2 14 0.0 105 15.31 348 559 1.00 / 1787.74 2 112
Average= 13.65
(KJ/cycle)

Cycle 238 GMT 20/ 5/2020 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.33 360 442 0.44 / 1786.18 2 31
2 14 -0.1 105 15.31 350 563 1.00 / 1786.75 2 113
Average= 13.74
(KJ/cycle)

Cycle 237 GMT 20/ 5/2020 5: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.33 362 444 0.44 / 1784.93 2 31
2 14 0.0 153 15.30 346 810 1.25 / 1785.74 2 117
Average= 13.84
(KJ/cycle)

Cycle 236 GMT 19/ 5/2020 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.33 369 453 0.45 / 1783.96 2 25
2 14 0.0 88 15.31 348 469 0.92 / 1784.43 2 127
3 14 0.0 12 15.30 337 62 0.98 / 1784.49 40 244
Average= 13.94
(KJ/cycle)

Cycle 235 GMT 19/ 5/2020 11: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.34 361 443 0.44 / 1782.89 2 30
2 14 0.0 112 15.31 357 612 1.06 / 1783.51 2 137
Average= 14.04
(KJ/cycle)

Cycle 234 GMT 19/ 5/2020 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.33 364 446 0.45 / 1781.61 2 30
2 14 0.0 159 15.30 347 844 1.29 / 1782.45 2 114
Average= 14.15
(KJ/cycle)

Cycle 233 GMT 18/ 5/2020 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.34 366 449 0.45 / 1780.62 2 37
2 14 -0.1 80 15.31 360 441 0.89 / 1781.06 2 111
3 14 -0.1 20 15.30 335 103 0.99 / 1781.16 36 244
Average= 14.25
(KJ/cycle)

Cycle 232 GMT 18/ 5/2020 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.35 364 447 0.45 / 1779.61 2 32
2 14 0.0 101 15.32 361 559 1.01 / 1780.17 2 104
Average= 14.36
(KJ/cycle)

Cycle 231 GMT 18/ 5/2020 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.34 357 438 0.44 / 1778.50 2 24
2 14 -0.1 125 15.31 347 664 1.10 / 1779.16 2 120
Average= 14.46
(KJ/cycle)

Cycle 230 GMT 17/ 5/2020 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.34 364 447 0.45 / 1777.53 2 30
2 14 -0.2 86 15.32 347 457 0.90 / 1777.99 2 115
3 14 -0.1 14 15.31 332 71 0.98 / 1778.06 34 244
Average= 14.57
(KJ/cycle)

Cycle 229 GMT 17/ 5/2020 18:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.33 353 433 0.43 / 1776.48 2 31
2 14 0.0 112 15.30 351 601 1.03 / 1777.08 2 134
Average= 14.69
(KJ/cycle)

Cycle 228 GMT 17/ 5/2020 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.33 360 442 0.44 / 1775.56 2 37
2 14 -0.1 33 15.32 358 181 0.62 / 1775.74 2 117
3 14 -0.3 67 15.31 302 310 0.93 / 1776.05 36 244
Average= 14.80
(KJ/cycle)

Cycle 227 GMT 17/ 5/2020 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.2 80 15.34 363 445 0.45 / 1774.36 2 33
2 14 -0.2 140 15.31 356 763 1.21 / 1775.12 2 106
Average= 14.92
(KJ/cycle)

Cycle 226 GMT 17/ 5/2020 11:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.3 80 15.31 372 456 0.46 / 1773.39 2 32
2 14 -0.2 39 15.30 374 223 0.68 / 1773.61 2 121
3 14 -0.3 61 15.29 318 297 0.98 / 1773.91 37 244
Average= 15.03
(KJ/cycle)

Cycle 225 GMT 17/ 5/2020 9:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.7 80 15.26 394 481 0.48 / 1772.08 2 38
2 14 0.5 150 15.23 373 852 1.33 / 1772.93 2 124
Average= 15.15
(KJ/cycle)

Cycle 224 GMT 17/ 5/2020 7: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 476.4 162 15.18 709 1744 1.74 / 1749.96 2 42
2 6 5645.1 69 14.60 3888 3917 5.66 / 1753.88 2 88
3 3 5550.6 20 14.69 3887 1142 6.80 / 1755.02 2 92
4 3 5223.1 1 14.91 3911 58 6.86 / 1755.08 2 88
5 7 5280.3 80 14.69 3691 4338 11.20 / 1759.41 2 94
6 13 4253.9 80 14.66 3090 3624 14.82 / 1763.04 2 97
7 13 3050.4 80 14.79 2396 2835 17.66 / 1765.87 2 97
8 13 2067.2 80 14.91 1791 2136 19.79 / 1768.01 2 96
9 13 1217.9 80 15.02 1260 1514 21.31 / 1769.52 2 93
10 13 908.3 80 15.02 1047 1258 22.57 / 1770.78 2 93
11 14 0.3 125 15.17 432 819 23.38 / 1771.60 2 101
Average= 15.27
(KJ/cycle)

Cycle 223 GMT 7/ 5/2020 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.2 164 15.23 476 1189 1.19 / 1728.38 2 26
2 6 5601.9 69 14.62 3845 3879 5.07 / 1732.26 2 70
3 7 5097.3 80 14.71 3594 4229 9.30 / 1736.49 2 80
4 13 4100.4 80 14.68 2982 3502 12.80 / 1739.99 2 84
5 13 3014.3 80 14.79 2345 2775 15.57 / 1742.77 2 98
6 13 1972.6 80 14.92 1717 2049 17.62 / 1744.82 2 98
7 13 1047.2 80 15.05 1139 1371 18.99 / 1746.19 2 93
8 13 945.2 80 15.01 1060 1273 20.27 / 1747.46 2 94
9 14 -0.6 116 15.16 430 756 21.02 / 1748.22 2 102
Average= 15.20
(KJ/cycle)

Cycle 222 GMT 27/ 4/2020 1:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 5681.2 201 14.94 1940 5826 5.83 / 1707.01 2 62
2 6 5669.1 70 14.59 3896 3979 9.80 / 1710.99 2 84
3 7 5114.0 80 14.72 3586 4223 14.03 / 1715.21 2 93
4 13 4199.5 80 14.66 3054 3582 17.61 / 1718.79 2 94
5 13 2875.7 80 14.82 2271 2692 20.30 / 1721.49 2 95
6 13 1968.0 80 14.92 1728 2063 22.36 / 1723.55 2 96
7 13 1276.9 80 14.99 1297 1555 23.92 / 1725.10 2 94
8 13 958.1 80 15.00 1075 1290 25.21 / 1726.39 2 95
9 14 -0.5 123 15.16 429 800 26.01 / 1727.19 2 115
Average= 15.15
(KJ/cycle)

Cycle 221 GMT 16/ 4/2020 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.1 156 15.28 902 2150 2.15 / 1678.73 2 28
2 6 5681.3 70 14.60 3878 3963 6.11 / 1682.69 2 66
3 3 5679.0 28 14.64 3943 1616 7.73 / 1684.31 2 62
4 3 5242.3 2 14.91 3854 115 7.84 / 1684.42 2 64
5 7 5282.4 80 14.69 3671 4314 12.16 / 1688.74 2 67
6 13 4460.5 80 14.63 3203 3749 15.91 / 1692.49 2 73
7 13 3345.4 80 14.75 2539 2996 18.90 / 1695.48 2 75
8 13 2037.2 80 14.93 1759 2101 21.00 / 1697.58 2 72
9 13 1220.0 80 15.03 1247 1499 22.50 / 1699.08 2 73
10 13 903.4 80 15.03 1042 1253 23.76 / 1700.34 2 70
11 14 -1.4 133 15.17 420 847 24.60 / 1701.18 2 113
Average= 15.05
(KJ/cycle)

Cycle 220 GMT 6/ 4/2020 19:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.29 338 413 0.41 / 1675.66 2 22
2 14 -0.1 183 15.26 329 919 1.33 / 1676.58 2 112
Average= 14.97
(KJ/cycle)

Cycle 219 GMT 6/ 4/2020 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.2 80 15.26 343 419 0.42 / 1674.75 2 30
2 14 -0.1 56 15.24 345 294 0.71 / 1675.04 3 114
3 14 -0.1 44 15.24 304 204 0.92 / 1675.25 49 244
Average= 15.09
(KJ/cycle)

Cycle 218 GMT 6/ 4/2020 17:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.22 351 427 0.43 / 1673.80 2 36
2 14 -0.3 95 15.20 348 503 0.93 / 1674.30 2 127
3 14 -0.2 5 15.19 349 27 0.96 / 1674.33 51 232
Average= 15.22
(KJ/cycle)

Cycle 217 GMT 6/ 4/2020 16:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 2.2 80 15.21 372 453 0.45 / 1672.21 2 42
2 14 1.7 215 15.17 357 1164 1.62 / 1673.37 2 104
Average= 15.35
(KJ/cycle)

Cycle 216 GMT 6/ 4/2020 14:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 5746.3 197 15.11 1029 3063 3.06 / 1651.96 2 40
2 6 5690.0 69 14.61 3886 3917 6.98 / 1655.87 2 74
3 7 4995.0 80 14.73 3514 4141 11.12 / 1660.01 2 86
4 13 4180.5 80 14.67 3035 3562 14.68 / 1663.58 2 90
5 13 2878.4 80 14.82 2271 2692 17.38 / 1666.27 2 89
6 13 1969.8 80 14.92 1730 2065 19.44 / 1668.33 2 90
7 13 1166.2 80 15.01 1231 1478 20.92 / 1669.81 2 90
8 13 851.7 80 15.02 1015 1220 22.14 / 1671.03 2 85
9 14 -0.5 112 15.16 427 725 22.86 / 1671.76 2 105
Average= 15.48
(KJ/cycle)

Cycle 215 GMT 27/ 3/2020 12:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 5762.1 195 14.86 2227 6453 6.45 / 1628.12 2 68
2 6 5746.4 69 14.58 3934 3958 10.41 / 1632.07 2 82
3 3 5296.3 5 14.83 3764 279 10.69 / 1632.35 2 80
4 7 5262.9 80 14.72 3654 4303 14.99 / 1636.65 2 83
5 13 4310.1 80 14.67 3100 3638 18.63 / 1640.29 2 89
6 13 3062.5 80 14.81 2371 2809 21.44 / 1643.10 2 87
7 13 1973.1 80 14.94 1713 2047 23.49 / 1645.15 2 88
8 13 1457.4 80 14.97 1386 1660 25.15 / 1646.81 2 90
9 13 923.8 80 15.02 1045 1256 26.40 / 1648.07 2 86
10 14 0.1 129 15.17 423 828 27.23 / 1648.89 2 107
Average= 15.41
(KJ/cycle)

Cycle 214 GMT 17/ 3/2020 11:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 5740.5 193 14.86 2224 6378 6.38 / 1600.90 2 57
2 6 5762.0 69 14.59 3937 3963 10.34 / 1604.86 2 75
3 3 5300.5 5 14.83 3801 282 10.62 / 1605.15 2 72
4 7 5283.3 80 14.71 3680 4331 14.95 / 1609.48 2 77
5 13 4251.7 80 14.67 3073 3606 18.56 / 1613.08 2 81
6 13 3208.4 80 14.77 2462 2909 21.47 / 1615.99 2 82
7 13 2011.2 80 14.94 1739 2078 23.55 / 1618.07 2 86
8 13 1243.0 80 15.02 1256 1509 25.06 / 1619.58 2 80
9 13 931.2 80 15.03 1042 1253 26.31 / 1620.83 2 83
10 14 -1.1 133 15.18 411 830 27.14 / 1621.66 2 109
Average= 15.30
(KJ/cycle)

Cycle 213 GMT 7/ 3/2020 9:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.1 142 15.15 1447 3113 3.11 / 1570.42 2 42
2 6 5740.7 69 14.59 3929 3955 7.07 / 1574.38 2 72
3 3 5738.8 31 14.65 3955 1796 8.86 / 1576.18 2 68
4 3 5555.7 20 14.70 3865 1136 10.00 / 1577.31 2 70
5 7 5312.1 80 14.67 3673 4311 14.31 / 1581.62 2 75
6 13 4488.5 80 14.64 3216 3767 18.08 / 1585.39 2 81
7 13 3282.5 80 14.77 2503 2958 21.04 / 1588.35 2 80
8 13 1984.4 80 14.95 1733 2073 23.11 / 1590.42 2 83
9 13 1399.8 80 14.99 1358 1629 24.74 / 1592.05 2 79
10 13 993.6 80 15.01 1096 1316 26.05 / 1593.36 2 82
11 13 25.7 80 15.18 446 542 26.59 / 1593.91 2 60
12 14 -2.4 52 15.17 420 331 26.93 / 1594.24 2 112
13 14 -2.4 48 15.15 391 284 27.21 / 1594.52 16 244
Average= 15.19
(KJ/cycle)

Cycle 212 GMT 26/ 2/2020 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.35 316 388 0.39 / 1566.56 2 19
2 14 0.0 161 15.33 306 755 1.14 / 1567.31 2 146
Average= 15.07
(KJ/cycle)

Cycle 211 GMT 25/ 2/2020 23: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.36 311 382 0.38 / 1565.28 2 14
2 14 -0.1 193 15.33 301 891 1.27 / 1566.17 2 104
Average= 15.21
(KJ/cycle)

Cycle 210 GMT 25/ 2/2020 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.35 317 389 0.39 / 1564.29 2 18
2 14 0.0 127 15.32 310 603 0.99 / 1564.90 2 118
Average= 15.34
(KJ/cycle)

Cycle 209 GMT 25/ 2/2020 15:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.34 318 390 0.39 / 1563.28 2 20
2 14 0.0 133 15.32 308 628 1.02 / 1563.90 2 135
Average= 15.48
(KJ/cycle)

Cycle 208 GMT 25/ 2/2020 12:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.34 317 389 0.39 / 1562.19 2 16
2 14 -0.1 146 15.32 311 696 1.08 / 1562.89 2 119
Average= 15.63
(KJ/cycle)

Cycle 207 GMT 25/ 2/2020 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.35 316 388 0.39 / 1561.15 2 21
2 14 0.0 138 15.32 306 647 1.03 / 1561.80 2 111
Average= 15.78
(KJ/cycle)

Cycle 206 GMT 25/ 2/2020 6:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.35 315 387 0.39 / 1560.04 2 15
2 14 -0.1 155 15.32 307 729 1.12 / 1560.77 2 110
Average= 15.93
(KJ/cycle)

Cycle 205 GMT 25/ 2/2020 4: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.35 312 383 0.38 / 1558.97 2 18
2 14 -0.1 146 15.32 304 680 1.06 / 1559.65 2 100
Average= 16.08
(KJ/cycle)

Cycle 204 GMT 25/ 2/2020 1: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.35 311 382 0.38 / 1557.84 2 17
2 14 0.0 163 15.33 300 750 1.13 / 1558.59 2 147
Average= 16.24
(KJ/cycle)

Cycle 203 GMT 24/ 2/2020 22:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.34 317 389 0.39 / 1556.87 2 17
2 14 0.0 125 15.32 306 586 0.98 / 1557.46 2 123
Average= 16.39
(KJ/cycle)

Cycle 202 GMT 24/ 2/2020 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.34 316 388 0.39 / 1555.82 2 16
2 14 0.0 140 15.31 308 660 1.05 / 1556.48 2 117
Average= 16.56
(KJ/cycle)

Cycle 201 GMT 24/ 2/2020 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.33 323 396 0.40 / 1554.88 2 20
2 14 0.0 116 15.31 310 551 0.95 / 1555.43 2 141
Average= 16.73
(KJ/cycle)

Cycle 200 GMT 24/ 2/2020 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 318 390 0.39 / 1553.83 2 24
2 14 -0.1 135 15.30 317 655 1.04 / 1554.49 2 144
Average= 16.90
(KJ/cycle)

Cycle 199 GMT 24/ 2/2020 14:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 316 387 0.39 / 1552.84 2 19
2 14 0.0 129 15.29 305 602 0.99 / 1553.44 2 119
Average= 17.07
(KJ/cycle)

Cycle 198 GMT 24/ 2/2020 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 318 390 0.39 / 1551.48 2 16
2 14 0.0 210 15.29 304 976 1.37 / 1552.45 2 137
Average= 17.25
(KJ/cycle)

Cycle 197 GMT 24/ 2/2020 11:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 318 390 0.39 / 1550.60 2 17
2 14 0.0 86 15.30 317 417 0.81 / 1551.02 2 111
3 14 0.0 14 15.29 309 66 0.87 / 1551.09 40 244
Average= 17.43
(KJ/cycle)

Cycle 196 GMT 24/ 2/2020 10:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 322 395 0.39 / 1549.74 2 13
2 14 -0.1 95 15.30 311 452 0.85 / 1550.19 2 128
3 14 -0.1 5 15.30 316 24 0.87 / 1550.21 62 244
Average= 17.62
(KJ/cycle)

Cycle 195 GMT 24/ 2/2020 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 327 401 0.40 / 1548.84 2 23
2 14 0.0 101 15.30 323 499 0.90 / 1549.34 2 125
Average= 17.81
(KJ/cycle)

Cycle 194 GMT 24/ 2/2020 7:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 317 389 0.39 / 1547.91 2 10
2 14 0.0 112 15.30 311 533 0.92 / 1548.44 2 120
Average= 18.01
(KJ/cycle)

Cycle 193 GMT 24/ 2/2020 6:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.31 318 389 0.39 / 1547.00 2 20
2 14 -0.1 108 15.29 313 517 0.91 / 1547.52 2 119
Average= 18.21
(KJ/cycle)

Cycle 192 GMT 24/ 2/2020 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.31 312 382 0.38 / 1545.98 2 14
2 14 0.0 135 15.29 308 636 1.02 / 1546.62 2 148
Average= 18.41
(KJ/cycle)

Cycle 191 GMT 24/ 2/2020 4: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.32 310 380 0.38 / 1544.79 2 20
2 14 0.0 174 15.29 302 803 1.18 / 1545.60 2 123
Average= 18.62
(KJ/cycle)

Cycle 190 GMT 24/ 2/2020 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.32 307 376 0.38 / 1543.95 2 19
2 14 -0.1 84 15.30 307 395 0.77 / 1544.34 2 109
3 14 0.0 16 15.29 289 71 0.84 / 1544.41 42 244
Average= 18.83
(KJ/cycle)

Cycle 189 GMT 24/ 2/2020 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.2 80 15.31 309 378 0.38 / 1543.10 2 15
2 14 0.0 101 15.29 304 469 0.85 / 1543.57 2 120
Average= 19.06
(KJ/cycle)

Cycle 188 GMT 24/ 2/2020 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 312 382 0.38 / 1542.25 2 21
2 14 -0.1 101 15.28 306 472 0.85 / 1542.72 2 105
Average= 19.28
(KJ/cycle)

Cycle 187 GMT 23/ 2/2020 23:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 326 399 0.40 / 1541.06 2 11
2 14 0.0 174 15.28 306 814 1.21 / 1541.87 2 171
Average= 19.52
(KJ/cycle)

Cycle 186 GMT 23/ 2/2020 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 325 398 0.40 / 1540.18 2 20
2 14 0.0 78 15.29 317 378 0.78 / 1540.56 2 102
3 14 -0.1 22 15.28 291 98 0.87 / 1540.66 44 244
Average= 19.75
(KJ/cycle)

Cycle 185 GMT 23/ 2/2020 21:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 316 387 0.39 / 1539.26 2 21
2 14 0.0 110 15.28 311 523 0.91 / 1539.78 2 151
Average= 20.00
(KJ/cycle)

Cycle 184 GMT 23/ 2/2020 20:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.31 318 389 0.39 / 1537.97 2 17
2 14 -0.1 193 15.28 306 902 1.29 / 1538.87 2 131
Average= 20.25
(KJ/cycle)

Cycle 183 GMT 23/ 2/2020 19:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 319 390 0.39 / 1537.11 2 22
2 14 -0.1 75 15.29 313 359 0.75 / 1537.47 2 123
3 14 0.0 25 15.28 285 109 0.86 / 1537.58 53 244
Average= 20.50
(KJ/cycle)

Cycle 182 GMT 23/ 2/2020 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.30 316 387 0.39 / 1536.21 2 21
2 14 0.0 110 15.27 309 519 0.91 / 1536.72 2 116
Average= 20.77
(KJ/cycle)

Cycle 181 GMT 23/ 2/2020 17:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.30 318 389 0.39 / 1534.88 2 20
2 14 0.0 200 15.27 308 941 1.33 / 1535.82 2 146
Average= 21.04
(KJ/cycle)

Cycle 180 GMT 23/ 2/2020 16:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.29 319 390 0.39 / 1534.03 2 26
2 14 -0.1 60 15.28 313 287 0.68 / 1534.32 3 122
3 14 0.0 40 15.27 276 169 0.85 / 1534.49 43 244
Average= 21.31
(KJ/cycle)

Cycle 179 GMT 23/ 2/2020 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.29 321 393 0.39 / 1533.16 2 24
2 14 -0.1 95 15.27 316 458 0.85 / 1533.62 2 130
3 14 -0.1 5 15.26 318 24 0.88 / 1533.64 54 237
Average= 21.60
(KJ/cycle)

Cycle 178 GMT 23/ 2/2020 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.29 322 394 0.39 / 1531.92 2 12
2 14 -0.1 178 15.27 312 848 1.24 / 1532.77 2 117
Average= 21.90
(KJ/cycle)

Cycle 177 GMT 23/ 2/2020 13:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.29 323 395 0.40 / 1531.06 2 20
2 14 -0.1 60 15.28 319 292 0.69 / 1531.35 2 116
3 14 0.0 40 15.27 284 173 0.86 / 1531.53 46 244
Average= 22.20
(KJ/cycle)

Cycle 176 GMT 23/ 2/2020 13: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.28 326 399 0.40 / 1530.18 2 19
2 14 -0.1 97 15.27 320 474 0.87 / 1530.65 2 151
3 14 -0.1 3 15.26 334 15 0.89 / 1530.66 70 157
Average= 22.51
(KJ/cycle)

Cycle 175 GMT 23/ 2/2020 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.29 323 395 0.40 / 1528.86 2 23
2 14 0.0 193 15.26 312 919 1.31 / 1529.78 2 114
Average= 22.83
(KJ/cycle)

Cycle 174 GMT 23/ 2/2020 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.29 328 401 0.40 / 1527.99 2 25
2 14 0.0 67 15.28 323 331 0.73 / 1528.32 2 100
3 14 -0.1 33 15.27 291 147 0.88 / 1528.46 36 244
Average= 23.16
(KJ/cycle)

Cycle 173 GMT 23/ 2/2020 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.28 329 402 0.40 / 1527.09 2 20
2 14 0.0 97 15.26 324 480 0.88 / 1527.57 2 140
3 14 -0.1 3 15.25 338 15 0.90 / 1527.58 59 137
Average= 23.50
(KJ/cycle)

Cycle 172 GMT 23/ 2/2020 9:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.28 338 413 0.41 / 1525.74 2 19
2 14 -0.1 191 15.25 324 944 1.36 / 1526.69 2 127
Average= 23.85
(KJ/cycle)

Cycle 171 GMT 23/ 2/2020 8:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.26 334 408 0.41 / 1524.82 2 23
2 14 0.0 86 15.24 335 439 0.85 / 1525.26 2 140
3 14 0.0 14 15.24 325 69 0.92 / 1525.33 56 244
Average= 24.21
(KJ/cycle)

Cycle 170 GMT 23/ 2/2020 7:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.23 334 407 0.41 / 1523.86 2 22
2 14 -0.2 112 15.21 326 555 0.96 / 1524.41 2 132
Average= 24.59
(KJ/cycle)

Cycle 169 GMT 23/ 2/2020 6:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.3 80 15.23 333 406 0.41 / 1522.28 2 26
2 14 -0.1 240 15.19 321 1170 1.58 / 1523.45 2 135
Average= 24.97
(KJ/cycle)

Cycle 168 GMT 23/ 2/2020 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.19 342 416 0.42 / 1521.37 2 27
2 14 0.0 78 15.18 335 397 0.81 / 1521.77 2 114
3 14 -0.1 22 15.17 325 108 0.92 / 1521.88 37 244
Average= 25.36
(KJ/cycle)

Cycle 167 GMT 23/ 2/2020 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.17 345 419 0.42 / 1520.34 2 31
2 14 0.0 118 15.15 344 615 1.03 / 1520.96 2 116
Average= 25.78
(KJ/cycle)

Cycle 166 GMT 23/ 2/2020 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 5.8 80 15.18 378 459 0.46 / 1518.74 2 31
2 14 2.2 225 15.14 348 1185 1.64 / 1519.92 2 105
Average= 26.21
(KJ/cycle)

Cycle 165 GMT 23/ 2/2020 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.1 155 15.16 410 963 0.96 / 1499.88 2 23
2 6 5703.7 69 14.63 3881 3918 4.88 / 1503.80 2 71
3 7 4596.3 80 14.79 3264 3862 8.74 / 1507.66 2 76
4 13 3685.0 80 14.75 2724 3214 11.96 / 1510.88 2 81
5 13 2490.8 80 14.89 2010 2394 14.35 / 1513.27 2 80
6 13 1992.8 80 14.90 1699 2025 16.38 / 1515.30 2 78
7 13 1017.0 80 15.05 1092 1315 17.69 / 1516.61 2 76
8 13 673.8 80 15.07 866 1044 18.74 / 1517.66 2 76
9 14 -0.7 90 15.17 410 560 19.30 / 1518.22 2 101
10 14 -0.7 10 15.16 404 61 19.36 / 1518.28 10 108
Average= 26.64
(KJ/cycle)

Cycle 164 GMT 12/ 2/2020 23:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 72.8 171 15.15 420 1088 1.09 / 1481.64 2 25
2 6 5540.4 69 14.65 3791 3832 4.92 / 1485.47 2 72
3 7 4425.8 80 14.81 3166 3751 8.67 / 1489.22 2 75
4 13 3509.0 80 14.78 2612 3088 11.76 / 1492.31 2 78
5 13 2242.3 80 14.93 1854 2214 13.97 / 1494.52 2 78
6 13 1566.1 80 14.98 1451 1739 15.71 / 1496.26 2 79
7 13 985.0 80 15.04 1067 1284 17.00 / 1497.55 2 75
8 13 309.3 80 15.14 622 753 17.75 / 1498.30 2 69
9 14 -0.6 84 15.17 410 522 18.27 / 1498.82 2 113
10 14 -0.4 16 15.16 399 97 18.37 / 1498.92 9 203
Average= 26.77
(KJ/cycle)

Cycle 163 GMT 2/ 2/2020 19: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.0 173 15.14 459 1202 1.20 / 1459.89 2 27
2 6 5705.8 69 14.61 3874 3905 5.11 / 1463.79 2 71
3 7 5191.9 80 14.72 3613 4255 9.36 / 1468.05 2 73
4 13 4291.8 80 14.68 3073 3609 12.97 / 1471.65 2 76
5 13 3049.9 80 14.82 2346 2781 15.75 / 1474.44 2 77
6 13 1984.3 80 14.95 1701 2034 17.79 / 1476.47 2 77
7 13 1168.3 80 15.05 1190 1433 19.22 / 1477.90 2 75
8 13 956.8 80 15.04 1046 1259 20.48 / 1479.16 2 76
9 13 353.1 80 15.12 646 781 21.26 / 1479.94 2 82
10 14 -1.5 45 15.17 416 284 21.54 / 1480.23 2 107
11 14 -1.4 55 15.15 388 323 21.87 / 1480.55 14 244
Average= 26.92
(KJ/cycle)

Cycle 162 GMT 23/ 1/2020 17: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 149.2 176 15.17 459 1225 1.23 / 1438.78 2 27
2 6 5602.5 70 14.63 3813 3905 5.13 / 1442.69 2 74
3 7 5060.3 80 14.74 3518 4148 9.28 / 1446.84 2 80
4 13 4136.8 80 14.71 2974 3500 12.78 / 1450.33 2 85
5 13 2837.1 80 14.86 2212 2630 15.41 / 1452.96 2 84
6 13 1999.0 80 14.94 1708 2041 17.45 / 1455.01 2 83
7 13 1025.1 80 15.07 1102 1329 18.78 / 1456.33 2 83
8 13 930.5 80 15.03 1029 1237 20.02 / 1457.57 2 84
9 13 22.8 80 15.19 426 518 20.53 / 1458.09 2 76
10 14 -0.7 37 15.18 410 230 20.76 / 1458.32 2 111
11 14 -0.8 63 15.16 381 364 21.13 / 1458.68 16 244
Average= 27.01
(KJ/cycle)

Cycle 161 GMT 13/ 1/2020 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 325.4 177 15.14 581 1557 1.56 / 1417.08 2 31
2 6 5606.0 70 14.63 3817 3909 5.47 / 1420.99 2 64
3 3 5222.9 1 14.88 3873 58 5.52 / 1421.05 2 69
4 7 5275.5 80 14.72 3638 4284 9.81 / 1425.33 2 68
5 13 4556.9 80 14.64 3224 3776 13.58 / 1429.11 2 71
6 13 3147.9 80 14.82 2402 2848 16.43 / 1431.96 2 72
7 13 1982.0 80 14.96 1698 2032 18.46 / 1433.99 2 76
8 13 1324.7 80 15.03 1284 1544 20.01 / 1435.53 2 72
9 13 915.0 80 15.05 1010 1216 21.22 / 1436.75 2 72
10 14 -0.4 135 15.20 394 808 22.03 / 1437.56 2 105
Average= 27.12
(KJ/cycle)

Cycle 160 GMT 3/ 1/2020 13:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 250.6 176 15.14 531 1415 1.41 / 1395.33 2 30
2 6 5674.0 70 14.62 3852 3942 5.36 / 1399.27 2 69
3 3 5232.4 1 14.94 3794 57 5.41 / 1399.33 2 63
4 7 5281.1 80 14.72 3649 4297 9.71 / 1403.63 2 73
5 13 4321.2 80 14.68 3078 3615 13.33 / 1407.24 2 75
6 13 3050.7 80 14.83 2328 2762 16.09 / 1410.00 2 80
7 13 1970.8 80 14.97 1682 2014 18.10 / 1412.02 2 83
8 13 1228.5 80 15.05 1229 1480 19.58 / 1413.50 2 80
9 13 915.5 80 15.05 1015 1222 20.80 / 1414.72 2 83
10 14 -0.1 133 15.19 399 806 21.61 / 1415.52 2 106
Average= 27.22
(KJ/cycle)

Cycle 159 GMT 24/12/2019 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 258.8 174 15.14 531 1399 1.40 / 1372.92 2 29
2 6 5495.2 69 14.64 3765 3803 5.20 / 1376.72 2 69
3 3 5252.8 3 14.91 3830 171 5.37 / 1376.89 2 64
4 3 5220.7 1 14.94 3884 58 5.43 / 1376.95 2 64
5 7 5292.6 80 14.71 3661 4308 9.74 / 1381.26 2 75
6 13 4428.6 80 14.67 3142 3687 13.43 / 1384.95 2 79
7 13 3231.4 80 14.79 2454 2904 16.33 / 1387.85 2 81
8 13 1965.9 80 14.97 1689 2023 18.35 / 1389.87 2 82
9 13 1473.4 80 14.99 1385 1661 20.01 / 1391.53 2 83
10 13 948.4 80 15.04 1051 1265 21.28 / 1392.80 2 84
11 13 18.7 80 15.20 427 519 21.80 / 1393.32 2 63
12 14 -0.7 45 15.18 404 276 22.07 / 1393.59 2 102
13 14 -0.7 55 15.17 385 321 22.40 / 1393.91 9 244
Average= 27.33
(KJ/cycle)

Cycle 158 GMT 14/12/2019 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 180.8 174 15.17 488 1288 1.29 / 1351.37 2 30
2 6 5373.9 69 14.66 3687 3730 5.02 / 1355.10 2 65
3 7 5239.8 80 14.72 3630 4275 9.29 / 1359.37 2 69
4 13 4135.2 80 14.72 2975 3503 12.80 / 1362.87 2 72
5 13 3093.4 80 14.82 2362 2800 15.60 / 1365.68 2 76
6 13 1945.5 80 14.97 1667 1996 17.59 / 1367.67 2 73
7 13 1181.5 80 15.06 1187 1430 19.02 / 1369.10 2 73
8 13 973.6 80 15.04 1046 1259 20.28 / 1370.36 2 74
9 13 102.4 80 15.18 469 570 20.85 / 1370.93 2 67
10 14 -1.0 39 15.18 400 237 21.09 / 1371.17 2 103
11 14 -0.7 61 15.17 381 353 21.44 / 1371.52 17 244
Average= 27.43
(KJ/cycle)

Cycle 157 GMT 4/12/2019 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 239.0 172 15.17 522 1362 1.36 / 1329.67 2 33
2 6 5668.7 69 14.63 3836 3872 5.23 / 1333.54 2 72
3 3 5310.9 6 14.82 3754 334 5.57 / 1333.87 2 69
4 7 5288.5 80 14.72 3647 4295 9.86 / 1338.17 2 74
5 13 4244.0 80 14.71 3039 3576 13.44 / 1341.75 2 76
6 13 3086.4 80 14.83 2375 2818 16.26 / 1344.56 2 76
7 13 1988.3 80 14.97 1701 2037 18.29 / 1346.60 2 80
8 13 1328.6 80 15.03 1294 1556 19.85 / 1348.16 2 77
9 13 806.5 80 15.08 950 1146 21.00 / 1349.30 2 70
10 14 -0.9 125 15.20 409 777 21.77 / 1350.08 2 107
Average= 27.55
(KJ/cycle)

Cycle 156 GMT 24/11/2019 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 269.3 168 15.16 546 1391 1.39 / 1307.36 2 36
2 6 5758.0 70 14.62 3894 3985 5.38 / 1311.35 2 66
3 3 5395.9 11 14.78 3731 607 5.98 / 1311.95 2 65
4 7 5283.3 80 14.71 3656 4302 10.28 / 1316.26 2 70
5 13 4322.6 80 14.70 3079 3621 13.91 / 1319.88 2 70
6 13 3261.3 80 14.80 2454 2906 16.81 / 1322.78 2 73
7 13 1970.2 80 14.98 1684 2018 18.83 / 1324.80 2 77
8 13 1209.2 80 15.06 1203 1449 20.28 / 1326.25 2 71
9 13 995.1 80 15.04 1059 1274 21.55 / 1327.52 2 73
10 14 -0.9 129 15.20 399 782 22.34 / 1328.31 2 106
Average= 27.67
(KJ/cycle)

Cycle 155 GMT 14/11/2019 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.0 166 15.18 484 1220 1.22 / 1285.58 2 36
2 6 5731.2 70 14.63 3880 3974 5.19 / 1289.55 2 65
3 3 5261.8 3 14.93 3776 169 5.36 / 1289.72 2 66
4 7 5261.4 80 14.72 3640 4286 9.65 / 1294.01 2 70
5 13 4396.4 80 14.68 3132 3678 13.33 / 1297.68 2 72
6 13 2996.1 80 14.85 2301 2734 16.06 / 1300.42 2 73
7 13 1978.2 80 14.98 1692 2028 18.09 / 1302.44 2 75
8 13 1314.9 80 15.04 1275 1534 19.62 / 1303.98 2 72
9 13 905.1 80 15.07 1013 1221 20.84 / 1305.20 2 71
10 14 -0.5 127 15.21 399 771 21.61 / 1305.97 2 109
Average= 27.79
(KJ/cycle)

Cycle 154 GMT 4/11/2019 2: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 143.6 167 15.19 462 1172 1.17 / 1264.18 2 36
2 6 5716.9 70 14.63 3873 3966 5.14 / 1268.15 2 70
3 7 5227.8 80 14.72 3624 4268 9.41 / 1272.41 2 73
4 13 4308.0 80 14.70 3092 3636 13.04 / 1276.05 2 79
5 13 2996.8 80 14.85 2325 2762 15.80 / 1278.81 2 75
6 13 1952.0 80 14.98 1693 2029 17.83 / 1280.84 2 80
7 13 1271.6 80 15.04 1262 1518 19.35 / 1282.36 2 77
8 13 961.0 80 15.05 1057 1273 20.62 / 1283.63 2 76
9 14 -0.1 118 15.21 404 725 21.35 / 1284.36 2 103
Average= 27.92
(KJ/cycle)

Cycle 153 GMT 24/10/2019 23:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 343.9 160 15.17 583 1415 1.42 / 1241.56 2 35
2 6 5716.7 70 14.63 3880 3974 5.39 / 1245.54 2 69
3 3 5573.3 22 14.71 3843 1244 6.63 / 1246.78 2 72
4 3 5218.9 1 14.93 3869 58 6.69 / 1246.84 2 70
5 7 5253.5 80 14.71 3637 4280 10.97 / 1251.12 2 71
6 13 4302.4 80 14.71 3068 3610 14.58 / 1254.73 2 72
7 13 3021.0 80 14.85 2320 2756 17.34 / 1257.49 2 77
8 13 1992.8 80 14.98 1701 2038 19.38 / 1259.52 2 76
9 13 1191.8 80 15.07 1201 1448 20.82 / 1260.97 2 74
10 13 987.6 80 15.05 1060 1276 22.10 / 1262.25 2 73
11 14 -0.4 125 15.22 399 759 22.86 / 1263.01 2 107
Average= 28.07
(KJ/cycle)

Cycle 152 GMT 14/10/2019 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 494.6 148 15.16 686 1539 1.54 / 1217.70 2 41
2 6 5704.3 70 14.63 3866 3959 5.50 / 1221.66 2 66
3 3 5703.0 29 14.69 3897 1660 7.16 / 1223.32 2 69
4 3 5361.0 9 14.84 3703 495 7.65 / 1223.82 2 71
5 7 5280.6 80 14.71 3659 4306 11.96 / 1228.12 2 73
6 13 4349.0 80 14.71 3102 3650 15.61 / 1231.77 2 77
7 13 3059.2 80 14.86 2334 2775 18.38 / 1234.55 2 77
8 13 1989.5 80 14.99 1688 2024 20.41 / 1236.57 2 79
9 13 1298.5 80 15.05 1268 1527 21.93 / 1238.10 2 80
10 13 993.3 80 15.05 1068 1286 23.22 / 1239.38 2 78
11 14 -0.1 129 15.22 390 766 23.99 / 1240.15 2 108
Average= 28.19
(KJ/cycle)

Cycle 151 GMT 4/10/2019 20:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 4001.2 156 15.17 693 1640 1.64 / 1194.41 2 35
2 6 5683.1 70 14.65 3846 3944 5.58 / 1198.35 2 65
3 3 5651.1 26 14.72 3866 1480 7.06 / 1199.83 2 69
4 3 5245.5 2 14.97 3826 115 7.18 / 1199.95 2 65
5 7 5260.2 80 14.71 3622 4262 11.44 / 1204.21 2 73
6 13 4376.7 80 14.70 3108 3655 15.10 / 1207.86 2 76
7 13 3112.9 80 14.85 2366 2811 17.91 / 1210.68 2 75
8 13 1969.2 80 14.99 1684 2019 19.93 / 1212.69 2 76
9 13 1162.0 80 15.08 1185 1430 21.36 / 1214.12 2 72
10 13 957.8 80 15.07 1039 1253 22.61 / 1215.38 2 74
11 14 0.5 131 15.22 394 786 23.39 / 1216.16 2 102
Average= 28.28
(KJ/cycle)

Cycle 150 GMT 24/ 9/2019 19:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.8 228 15.22 445 1544 1.54 / 1178.97 2 34
2 6 4004.9 59 14.86 2867 2514 4.06 / 1181.48 2 67
3 3 3640.4 7 15.02 2704 284 4.34 / 1181.76 2 68
4 7 3518.8 80 14.94 2580 3084 7.43 / 1184.85 2 75
5 13 2580.6 80 14.99 2020 2422 9.85 / 1187.27 2 75
6 13 1997.0 80 15.01 1667 2002 11.85 / 1189.27 2 71
7 13 997.7 80 15.15 1047 1269 13.12 / 1190.54 2 71
8 13 893.6 80 15.11 976 1180 14.30 / 1191.72 2 75
9 13 2.3 80 15.26 394 481 14.78 / 1192.20 2 58
10 14 -0.2 37 15.24 387 218 15.00 / 1192.42 2 113
11 14 -0.2 63 15.22 365 350 15.35 / 1192.77 8 244
Average= 28.40
(KJ/cycle)

Cycle 149 GMT 23/ 9/2019 2:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 4000.4 251 15.14 744 2827 2.83 / 1163.64 2 39
2 6 4005.0 60 14.85 2874 2561 5.39 / 1166.20 2 66
3 3 3787.3 15 14.95 2801 628 6.02 / 1166.83 2 70
4 3 3566.4 3 15.09 2853 129 6.15 / 1166.96 2 69
5 7 3504.7 80 14.93 2593 3097 9.24 / 1170.06 2 71
6 13 2544.5 80 15.00 2014 2417 11.66 / 1172.47 2 69
7 13 1928.7 80 15.03 1646 1979 13.64 / 1174.45 2 70
8 13 926.5 80 15.16 1022 1239 14.88 / 1175.69 2 68
9 13 706.5 80 15.15 863 1046 15.92 / 1176.74 2 72
10 14 -0.1 114 15.25 392 681 16.61 / 1177.42 2 113
Average= 28.72
(KJ/cycle)

Cycle 148 GMT 21/ 9/2019 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.2 210 15.22 443 1416 1.42 / 1146.46 2 33
2 6 4004.5 60 14.86 2863 2553 3.97 / 1149.01 2 64
3 3 3985.7 27 14.91 2892 1164 5.13 / 1150.18 2 68
4 3 3579.5 4 15.06 2695 162 5.30 / 1150.34 2 69
5 7 3503.7 80 14.94 2589 3094 8.39 / 1153.43 2 71
6 13 2613.0 80 14.98 2061 2470 10.86 / 1155.90 2 74
7 13 1966.4 80 15.02 1659 1993 12.85 / 1157.90 2 71
8 13 960.3 80 15.15 1031 1250 14.10 / 1159.14 2 68
9 13 633.0 80 15.17 818 993 15.10 / 1160.14 2 70
10 14 -0.2 114 15.25 390 678 15.77 / 1160.82 2 112
Average= 29.02
(KJ/cycle)

Cycle 147 GMT 19/ 9/2019 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 79.7 200 15.26 391 1193 1.19 / 1130.44 2 29
2 6 4004.6 60 14.87 2883 2572 3.77 / 1133.01 2 64
3 3 3926.7 23 14.92 2859 981 4.75 / 1133.99 2 69
4 3 3564.0 3 15.10 2734 124 4.87 / 1134.11 2 66
5 7 3520.8 80 14.93 2610 3117 7.99 / 1137.23 2 70
6 13 2826.4 80 14.94 2203 2633 10.62 / 1139.86 2 69
7 13 1999.0 80 15.01 1686 2025 12.65 / 1141.89 2 72
8 13 944.7 80 15.15 1038 1258 13.90 / 1143.15 2 66
9 13 841.8 80 15.12 965 1167 15.07 / 1144.31 2 72
10 14 -0.3 118 15.24 405 728 15.80 / 1145.04 2 108
Average= 29.36
(KJ/cycle)

Cycle 146 GMT 18/ 9/2019 3:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.29 336 411 0.41 / 1128.73 2 42
2 14 0.0 104 15.27 323 513 0.92 / 1129.24 2 107
Average= 29.72
(KJ/cycle)

Cycle 145 GMT 18/ 9/2019 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.28 337 412 0.41 / 1127.74 2 24
2 14 -0.1 116 15.26 328 581 0.99 / 1128.32 2 109
Average= 30.50
(KJ/cycle)

Cycle 144 GMT 18/ 9/2019 1:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.27 339 414 0.41 / 1126.66 2 35
2 14 -0.2 135 15.24 325 669 1.08 / 1127.33 2 110
Average= 31.31
(KJ/cycle)

Cycle 143 GMT 18/ 9/2019 0:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.25 332 405 0.41 / 1125.41 2 29
2 14 -0.1 168 15.22 327 836 1.24 / 1126.24 2 107
Average= 32.18
(KJ/cycle)

Cycle 142 GMT 17/ 9/2019 23:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.23 336 409 0.41 / 1124.36 2 30
2 14 0.0 131 15.21 324 646 1.05 / 1125.00 2 103
Average= 33.09
(KJ/cycle)

Cycle 141 GMT 17/ 9/2019 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.22 347 423 0.42 / 1123.17 2 42
2 14 -0.1 153 15.19 333 774 1.20 / 1123.95 2 108
Average= 34.06
(KJ/cycle)

Cycle 140 GMT 17/ 9/2019 21:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.22 344 419 0.42 / 1121.85 2 32
2 14 -0.1 178 15.19 334 903 1.32 / 1122.75 2 102
Average= 35.09
(KJ/cycle)

Cycle 139 GMT 17/ 9/2019 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.21 353 430 0.43 / 1120.74 2 41
2 14 -0.1 131 15.19 347 690 1.12 / 1121.43 2 112
Average= 36.18
(KJ/cycle)

Cycle 138 GMT 17/ 9/2019 20:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.3 80 15.25 380 464 0.46 / 1119.20 2 42
2 14 0.5 204 15.21 359 1114 1.58 / 1120.31 2 109
Average= 37.34
(KJ/cycle)

Cycle 137 GMT 17/ 9/2019 19:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.0 200 15.17 391 1186 1.19 / 1105.51 2 30
2 6 4005.3 59 14.87 2889 2535 3.72 / 1108.04 2 64
3 3 3523.8 1 15.09 2766 42 3.76 / 1108.08 2 65
4 7 3490.4 80 14.95 2604 3114 6.88 / 1111.20 2 72
5 13 2622.0 80 14.99 2077 2491 9.37 / 1113.69 2 72
6 13 1827.7 80 15.06 1598 1925 11.29 / 1115.61 2 69
7 13 1106.7 80 15.13 1144 1385 12.68 / 1117.00 2 69
8 13 672.5 80 15.17 846 1027 13.70 / 1118.02 2 64
9 14 -0.5 116 15.25 400 708 14.41 / 1118.73 2 113
Average= 38.58
(KJ/cycle)

Cycle 136 GMT 16/ 9/2019 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.18 351 426 0.43 / 1103.79 2 43
2 14 -0.1 74 15.17 349 392 0.82 / 1104.19 2 122
3 14 -0.1 26 15.16 340 134 0.95 / 1104.32 13 244
Average= 39.44
(KJ/cycle)

Cycle 135 GMT 16/ 9/2019 2:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.21 365 444 0.44 / 1102.84 2 36
2 14 0.0 54 15.19 354 290 0.73 / 1103.13 2 107
3 14 0.0 46 15.18 339 237 0.97 / 1103.37 10 244
Average= 40.87
(KJ/cycle)

Cycle 134 GMT 16/ 9/2019 1:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.3 80 15.24 391 477 0.48 / 1101.83 2 52
2 14 0.4 89 15.22 376 509 0.99 / 1102.34 2 107
3 14 0.3 11 15.20 366 61 1.05 / 1102.40 6 127
Average= 42.40
(KJ/cycle)

Cycle 133 GMT 16/ 9/2019 1:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.4 201 15.20 433 1323 1.32 / 1088.47 2 36
2 6 4004.4 59 14.86 2901 2543 3.87 / 1091.01 2 67
3 7 3467.6 80 14.95 2593 3101 6.97 / 1094.11 2 74
4 13 2510.2 80 15.01 2013 2417 9.38 / 1096.53 2 71
5 13 1743.5 80 15.07 1552 1871 11.26 / 1098.40 2 77
6 13 944.8 80 15.16 1052 1276 12.53 / 1099.68 2 76
7 13 617.9 80 15.18 826 1003 13.53 / 1100.68 2 77
8 14 -0.1 108 15.26 406 669 14.20 / 1101.35 2 102
Average= 44.05
(KJ/cycle)

Cycle 132 GMT 14/ 9/2019 8:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.8 199 15.20 437 1322 1.32 / 1073.72 2 36
2 6 4005.9 60 14.86 2894 2580 3.90 / 1076.30 2 72
3 3 3563.0 3 15.07 2805 127 4.03 / 1076.43 2 78
4 3 3532.5 1 15.13 2780 42 4.07 / 1076.47 2 76
5 7 3528.2 80 14.94 2631 3145 7.22 / 1079.62 2 79
6 13 2785.2 80 14.97 2181 2612 9.83 / 1082.23 2 79
7 13 1955.1 80 15.03 1684 2025 11.85 / 1084.25 2 82
8 13 930.8 80 15.16 1039 1260 13.11 / 1085.51 2 79
9 13 499.2 80 15.20 753 916 14.03 / 1086.43 2 75
10 14 -0.3 114 15.26 412 717 14.74 / 1087.15 2 117
Average= 45.30
(KJ/cycle)

Cycle 131 GMT 12/ 9/2019 15:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.4 196 15.13 375 1112 1.11 / 1059.07 2 30
2 6 4006.0 60 14.88 2883 2574 3.69 / 1061.64 2 65
3 3 3614.7 6 15.01 2766 249 3.94 / 1061.89 2 69
4 7 3538.6 80 14.94 2625 3137 7.07 / 1065.03 2 73
5 13 2836.6 80 14.95 2200 2631 9.70 / 1067.66 2 72
6 13 1853.3 80 15.05 1615 1944 11.65 / 1069.60 2 72
7 13 957.3 80 15.16 1053 1277 12.93 / 1070.88 2 69
8 13 407.7 80 15.22 681 829 13.75 / 1071.71 2 68
9 14 0.0 112 15.26 405 692 14.45 / 1072.40 2 101
Average= 46.63
(KJ/cycle)

Cycle 130 GMT 10/ 9/2019 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.16 332 403 0.40 / 1057.46 2 26
2 14 -0.1 73 15.15 332 367 0.77 / 1057.83 2 111
3 14 -0.1 27 15.14 307 125 0.90 / 1057.95 37 244
Average= 48.09
(KJ/cycle)

Cycle 129 GMT 10/ 9/2019 23: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.16 324 393 0.39 / 1056.58 2 24
2 14 0.0 65 15.15 326 321 0.71 / 1056.90 2 110
3 14 0.1 35 15.14 304 161 0.88 / 1057.06 25 244
Average= 50.34
(KJ/cycle)

Cycle 128 GMT 10/ 9/2019 22:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.16 324 393 0.39 / 1055.70 2 30
2 14 0.0 69 15.15 326 341 0.73 / 1056.04 2 112
3 14 0.1 31 15.14 306 144 0.88 / 1056.18 28 244
Average= 52.81
(KJ/cycle)

Cycle 127 GMT 10/ 9/2019 22:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.15 327 396 0.40 / 1054.83 2 34
2 14 0.1 42 15.15 327 208 0.60 / 1055.04 2 113
3 14 0.0 58 15.14 306 269 0.87 / 1055.31 11 244
Average= 55.54
(KJ/cycle)

Cycle 126 GMT 10/ 9/2019 21:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.15 329 399 0.40 / 1053.96 2 33
2 14 0.0 39 15.14 327 193 0.59 / 1054.15 2 120
3 14 0.0 61 15.13 306 282 0.87 / 1054.43 15 244
Average= 58.58
(KJ/cycle)

Cycle 125 GMT 10/ 9/2019 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.15 324 393 0.39 / 1053.08 2 41
2 14 0.0 37 15.14 327 183 0.58 / 1053.27 2 112
3 14 -0.1 63 15.13 306 292 0.87 / 1053.56 11 244
Average= 61.97
(KJ/cycle)

Cycle 124 GMT 10/ 9/2019 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.15 329 399 0.40 / 1052.21 2 37
2 14 -0.2 39 15.14 332 196 0.59 / 1052.41 2 111
3 14 0.1 61 15.13 308 284 0.88 / 1052.69 18 244
Average= 65.79
(KJ/cycle)

Cycle 123 GMT 10/ 9/2019 20:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.14 328 397 0.40 / 1051.33 2 41
2 14 0.0 37 15.14 328 184 0.58 / 1051.52 2 115
3 14 -0.1 63 15.12 310 295 0.88 / 1051.81 15 244
Average= 70.12
(KJ/cycle)

Cycle 122 GMT 10/ 9/2019 20:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.14 337 408 0.41 / 1050.45 2 35
2 14 0.0 37 15.13 329 184 0.59 / 1050.64 2 109
3 14 0.0 63 15.12 312 297 0.89 / 1050.94 14 244
Average= 75.07
(KJ/cycle)

Cycle 121 GMT 10/ 9/2019 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.13 338 409 0.41 / 1049.56 2 47
2 14 -0.1 37 15.13 334 187 0.60 / 1049.75 2 112
3 14 0.0 63 15.11 312 297 0.89 / 1050.05 17 244
Average= 80.77
(KJ/cycle)

Cycle 120 GMT 10/ 9/2019 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.13 332 402 0.40 / 1048.67 2 34
2 14 -0.1 35 15.12 337 178 0.58 / 1048.84 2 103
3 14 0.0 65 15.11 315 309 0.89 / 1049.15 14 244
Average= 87.43
(KJ/cycle)

Cycle 119 GMT 10/ 9/2019 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.14 341 413 0.41 / 1047.78 2 59
2 14 0.0 28 15.13 335 142 0.55 / 1047.92 2 101
3 14 0.0 72 15.12 314 342 0.90 / 1048.26 10 244
Average= 95.30
(KJ/cycle)

Cycle 118 GMT 10/ 9/2019 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.14 337 408 0.41 / 1046.88 2 49
2 14 0.0 33 15.14 335 167 0.58 / 1047.05 2 107
3 14 -0.1 67 15.12 318 322 0.90 / 1047.37 11 244
Average= 104.74
(KJ/cycle)

Cycle 117 GMT 10/ 9/2019 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.15 343 416 0.42 / 1045.97 2 38
2 14 0.0 35 15.14 343 182 0.60 / 1046.15 2 112
3 14 -0.1 65 15.13 324 319 0.92 / 1046.47 10 244
Average= 116.27
(KJ/cycle)

Cycle 116 GMT 10/ 9/2019 17:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.2 80 15.15 350 424 0.42 / 1045.05 2 46
2 14 0.0 33 15.15 351 175 0.60 / 1045.22 2 105
3 14 0.0 67 15.13 328 332 0.93 / 1045.55 9 244
Average= 130.69
(KJ/cycle)

Cycle 115 GMT 10/ 9/2019 17:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.17 365 443 0.44 / 1044.10 2 48
2 14 -0.1 35 15.16 353 187 0.63 / 1044.29 2 107
3 14 0.0 65 15.15 337 332 0.96 / 1044.62 15 244
Average= 149.23
(KJ/cycle)

Cycle 114 GMT 10/ 9/2019 17: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.20 370 450 0.45 / 1043.12 2 37
2 14 0.1 39 15.19 363 215 0.66 / 1043.34 2 105
3 14 0.0 61 15.17 348 322 0.99 / 1043.66 12 244
Average= 173.94
(KJ/cycle)

Cycle 113 GMT 10/ 9/2019 16:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.2 80 15.23 391 476 0.48 / 1042.10 2 55
2 14 0.3 54 15.21 380 312 0.79 / 1042.42 2 118
3 14 0.2 46 15.19 366 256 1.04 / 1042.67 12 244
Average= 208.53
(KJ/cycle)

Cycle 112 GMT 10/ 9/2019 16:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.1 188 15.34 379 1093 1.09 / 1027.50 2 30
2 6 4007.7 60 14.87 2908 2595 3.69 / 1030.09 2 64
3 3 3860.8 20 14.93 2864 855 4.54 / 1030.95 2 72
4 3 3544.2 2 15.10 2797 84 4.63 / 1031.03 2 69
5 7 3526.7 80 14.92 2626 3134 7.76 / 1034.17 2 72
6 13 2717.1 80 14.95 2147 2568 10.33 / 1036.73 2 74
7 13 1990.8 80 15.01 1704 2046 12.38 / 1038.78 2 72
8 13 980.2 80 15.14 1078 1306 13.68 / 1040.09 2 73
9 13 425.8 80 15.20 705 857 14.54 / 1040.94 2 72
10 14 -0.3 110 15.24 408 684 15.22 / 1041.63 2 102
Average= 260.41
(KJ/cycle)

Cycle 111 GMT 9/ 9/2019 0:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.0 391 15.31 378 2263 2.26 / 1024.11 2 30
2 6 968.1 57 15.23 1013 879 3.14 / 1024.99 2 56
3 7 3.6 80 15.45 346 428 3.57 / 1025.42 2 39
4 14 0.0 196 15.41 326 985 4.55 / 1026.41 3 122
Average= 342.14
(KJ/cycle)

Cycle 110 GMT 8/ 9/2019 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.4 403 15.31 384 2369 2.37 / 1019.55 2 30
2 6 959.8 57 15.24 1001 870 3.24 / 1020.42 2 51
3 7 0.1 80 15.45 349 431 3.67 / 1020.85 2 39
4 14 -0.1 195 15.41 333 1001 4.67 / 1021.85 2 114
Average= 510.93
(KJ/cycle)

Cycle 109 GMT 7/ 9/2019 12: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.7 415 15.34 389 2476 2.48 / 1015.07 2 33
2 6 808.0 57 15.26 896 779 3.26 / 1015.85 2 52
3 7 1.5 80 15.45 344 425 3.68 / 1016.28 2 40
4 14 0.4 180 15.41 325 901 4.58 / 1017.18 2 100
Average= 1017.18
(KJ/cycle)

Cycle 103 GMT 6/ 9/2019 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 633.7 411 15.23 762 4770 4.77 / 1007.91 2 38
2 6 1012.4 57 15.15 995 859 5.63 / 1008.77 2 42
3 3 1065.8 23 15.26 1091 383 6.01 / 1009.16 2 57
4 3 713.7 5 15.34 901 69 6.08 / 1009.23 2 55
5 7 609.7 80 15.34 793 973 7.05 / 1010.20 2 58
6 13 517.6 80 15.31 732 897 7.95 / 1011.09 2 58
7 13 26.9 80 15.34 406 498 8.45 / 1011.59 2 57
8 13 12.0 80 15.32 383 469 8.92 / 1012.06 2 151
9 14 -0.6 7 15.31 390 42 8.96 / 1012.10 2 108
10 14 -0.6 93 15.29 347 493 9.45 / 1012.60 29 244
Average= 92.05
(KJ/cycle)

Cycle 102 GMT 5/ 9/2019 18:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.3 415 15.22 373 2356 2.36 / 1001.20 2 32
2 6 634.7 57 15.25 779 677 3.03 / 1001.88 2 50
3 7 0.0 80 15.46 335 414 3.45 / 1002.29 2 46
4 14 -0.1 172 15.43 321 852 4.30 / 1003.14 2 100
Average= 100.31
(KJ/cycle)

Cycle 101 GMT 5/ 9/2019 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.2 80 15.23 320 390 0.39 / 998.36 2 31
2 14 0.0 101 15.21 313 481 0.87 / 998.84 2 108
Average= 110.98
(KJ/cycle)

Cycle 100 GMT 4/ 9/2019 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.23 324 395 0.39 / 997.38 2 26
2 14 0.0 125 15.21 315 599 0.99 / 997.97 2 105
Average= 124.75
(KJ/cycle)

Cycle 99 GMT 4/ 9/2019 23:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.24 327 399 0.40 / 996.19 2 21
2 14 0.0 165 15.22 313 786 1.18 / 996.98 2 118
Average= 142.43
(KJ/cycle)

Cycle 98 GMT 4/ 9/2019 22:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.26 325 397 0.40 / 995.31 2 18
2 14 0.0 75 15.24 322 368 0.76 / 995.68 2 106
3 14 0.0 25 15.23 303 115 0.88 / 995.80 30 244
Average= 165.97
(KJ/cycle)

Cycle 97 GMT 4/ 9/2019 22:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.27 323 395 0.39 / 994.43 2 30
2 14 -0.1 93 15.25 316 448 0.84 / 994.88 2 143
3 14 -0.1 7 15.24 315 34 0.88 / 994.92 54 244
Average= 198.98
(KJ/cycle)

Cycle 96 GMT 4/ 9/2019 21:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.29 328 401 0.40 / 993.51 2 32
2 14 0.0 108 15.27 321 529 0.93 / 994.04 2 110
Average= 248.51
(KJ/cycle)

Cycle 95 GMT 4/ 9/2019 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.34 332 407 0.41 / 992.48 2 30
2 14 0.0 129 15.31 317 626 1.03 / 993.11 2 115
Average= 331.04
(KJ/cycle)

Cycle 94 GMT 4/ 9/2019 20:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.3 80 15.40 335 413 0.41 / 991.29 2 33
2 14 0.0 161 15.37 317 784 1.20 / 992.07 2 122
Average= 496.04
(KJ/cycle)

Cycle 93 GMT 4/ 9/2019 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.5 80 15.49 339 420 0.42 / 989.80 2 30
2 14 -0.2 215 15.44 326 1082 1.50 / 990.88 2 117
Average= 990.88
(KJ/cycle)

Cycle 80 GMT 3/ 9/2019 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.18 312 379 0.38 / 988.91 2 29
2 14 -0.1 88 15.17 305 407 0.79 / 989.32 2 112
3 14 0.0 12 15.17 304 55 0.84 / 989.38 32 244
Average= 12.21
(KJ/cycle)

Cycle 79 GMT 3/ 9/2019 22:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.18 317 385 0.38 / 988.05 2 26
2 14 0.1 103 15.17 309 483 0.87 / 988.53 2 103
Average= 12.36
(KJ/cycle)

Cycle 78 GMT 3/ 9/2019 22:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.18 316 384 0.38 / 987.10 2 32
2 14 0.0 123 15.17 303 565 0.95 / 987.67 2 123
Average= 12.50
(KJ/cycle)

Cycle 77 GMT 3/ 9/2019 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.18 320 389 0.39 / 986.24 2 34
2 14 -0.1 74 15.17 316 355 0.74 / 986.60 2 114
3 14 -0.1 26 15.16 305 120 0.86 / 986.72 17 244
Average= 12.65
(KJ/cycle)

Cycle 76 GMT 3/ 9/2019 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.18 315 383 0.38 / 985.38 2 27
2 14 0.0 86 15.17 310 404 0.79 / 985.79 2 109
3 14 -0.1 14 15.16 311 66 0.85 / 985.85 17 129
Average= 12.80
(KJ/cycle)

Cycle 75 GMT 3/ 9/2019 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.18 318 386 0.39 / 984.53 2 27
2 14 0.1 97 15.16 311 457 0.84 / 984.99 2 103
3 14 -0.1 3 15.16 324 15 0.86 / 985.00 16 61
Average= 12.96
(KJ/cycle)

Cycle 74 GMT 3/ 9/2019 20:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.17 316 383 0.38 / 983.63 2 32
2 14 -0.1 108 15.16 315 516 0.90 / 984.14 2 110
Average= 13.12
(KJ/cycle)

Cycle 73 GMT 3/ 9/2019 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.17 322 391 0.39 / 982.75 2 29
2 14 0.0 103 15.15 315 492 0.88 / 983.24 2 109
Average= 13.29
(KJ/cycle)

Cycle 72 GMT 3/ 9/2019 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.17 322 391 0.39 / 981.89 2 28
2 14 0.0 69 15.16 311 325 0.72 / 982.22 2 101
3 14 -0.1 31 15.15 310 146 0.86 / 982.36 19 244
Average= 13.46
(KJ/cycle)

Cycle 71 GMT 3/ 9/2019 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.2 80 15.16 323 392 0.39 / 981.02 2 42
2 14 -0.1 88 15.15 316 421 0.81 / 981.44 2 109
3 14 0.0 12 15.14 316 57 0.87 / 981.50 14 125
Average= 13.63
(KJ/cycle)

Cycle 70 GMT 3/ 9/2019 19: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.16 323 392 0.39 / 980.14 2 40
2 14 -0.1 97 15.14 325 477 0.87 / 980.61 2 107
3 14 0.0 3 15.14 318 14 0.88 / 980.63 21 59
Average= 13.81
(KJ/cycle)

Cycle 69 GMT 3/ 9/2019 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.15 333 404 0.40 / 979.24 2 39
2 14 -0.1 103 15.14 326 508 0.91 / 979.75 2 107
Average= 14.00
(KJ/cycle)

Cycle 68 GMT 3/ 9/2019 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.15 325 394 0.39 / 978.26 2 38
2 14 0.0 119 15.13 321 578 0.97 / 978.83 2 108
Average= 14.19
(KJ/cycle)

Cycle 67 GMT 3/ 9/2019 17:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.15 326 395 0.40 / 977.23 2 38
2 14 -0.1 131 15.13 318 630 1.03 / 977.86 2 101
Average= 14.38
(KJ/cycle)

Cycle 66 GMT 3/ 9/2019 17:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.14 333 403 0.40 / 976.22 2 34
2 14 0.0 127 15.13 323 621 1.02 / 976.84 2 103
Average= 14.58
(KJ/cycle)

Cycle 65 GMT 3/ 9/2019 17: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.14 324 392 0.39 / 975.32 2 38
2 14 0.0 67 15.13 327 331 0.72 / 975.65 2 105
3 14 0.0 33 15.12 316 158 0.88 / 975.81 9 244
Average= 14.79
(KJ/cycle)

Cycle 64 GMT 3/ 9/2019 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.13 333 403 0.40 / 974.44 2 41
2 14 -0.1 78 15.12 330 389 0.79 / 974.83 2 101
3 14 0.0 22 15.11 312 104 0.90 / 974.93 14 165
Average= 15.00
(KJ/cycle)

Cycle 63 GMT 3/ 9/2019 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.12 334 404 0.40 / 973.54 2 43
2 14 0.0 93 15.11 329 462 0.87 / 974.00 2 105
3 14 -0.2 7 15.10 325 34 0.90 / 974.03 18 93
Average= 15.22
(KJ/cycle)

Cycle 62 GMT 3/ 9/2019 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.12 334 404 0.40 / 972.64 2 38
2 14 0.1 97 15.11 328 481 0.88 / 973.12 2 106
3 14 0.0 3 15.10 323 15 0.90 / 973.13 19 63
Average= 15.45
(KJ/cycle)

Cycle 61 GMT 3/ 9/2019 15:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.1 80 15.11 334 404 0.40 / 971.71 2 38
2 14 0.0 105 15.10 328 520 0.92 / 972.23 2 107
Average= 15.68
(KJ/cycle)

Cycle 60 GMT 3/ 9/2019 15: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.10 333 402 0.40 / 970.74 2 44
2 14 0.0 114 15.09 329 566 0.97 / 971.31 2 104
Average= 15.92
(KJ/cycle)

Cycle 59 GMT 3/ 9/2019 14:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.10 330 399 0.40 / 969.75 2 36
2 14 -0.1 121 15.08 327 597 1.00 / 970.34 2 104
Average= 16.17
(KJ/cycle)

Cycle 58 GMT 3/ 9/2019 14:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.09 333 402 0.40 / 968.73 2 28
2 14 0.0 127 15.07 323 618 1.02 / 969.35 2 109
Average= 16.43
(KJ/cycle)

Cycle 57 GMT 3/ 9/2019 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.09 333 402 0.40 / 967.62 2 32
2 14 0.0 142 15.07 330 706 1.11 / 968.33 2 109
Average= 16.70
(KJ/cycle)

Cycle 56 GMT 3/ 9/2019 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.09 331 400 0.40 / 966.48 2 30
2 14 0.0 148 15.07 330 736 1.14 / 967.22 2 100
Average= 16.97
(KJ/cycle)

Cycle 55 GMT 3/ 9/2019 13: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.09 341 412 0.41 / 965.28 2 38
2 14 -0.1 161 15.07 331 803 1.21 / 966.08 2 109
Average= 17.25
(KJ/cycle)

Cycle 54 GMT 3/ 9/2019 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.10 339 410 0.41 / 964.02 2 43
2 14 0.0 168 15.08 336 851 1.26 / 964.87 2 105
Average= 17.54
(KJ/cycle)

Cycle 53 GMT 3/ 9/2019 12:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 0.0 80 15.12 343 415 0.41 / 962.68 2 42
2 14 0.0 185 15.10 332 927 1.34 / 963.61 2 110
Average= 17.84
(KJ/cycle)

Cycle 52 GMT 3/ 9/2019 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 -0.1 80 15.15 349 423 0.42 / 961.32 2 41
2 14 0.0 183 15.12 342 946 1.37 / 962.27 2 104
Average= 18.16
(KJ/cycle)

Cycle 51 GMT 3/ 9/2019 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 2.1 80 15.21 383 466 0.47 / 959.62 2 42
2 14 0.4 238 15.17 354 1278 1.74 / 960.90 2 103
Average= 18.48
(KJ/cycle)

Cycle 50 GMT 3/ 9/2019 10:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.5 132 15.17 429 859 0.86 / 939.30 2 36
2 6 5743.3 70 14.64 3891 3987 4.85 / 943.28 2 68
3 7 5204.8 80 14.77 3588 4240 9.09 / 947.52 2 69
4 13 4252.8 80 14.74 3038 3582 12.67 / 951.11 2 73
5 13 2972.5 80 14.88 2285 2720 15.39 / 953.83 2 75
6 13 1983.2 80 14.99 1684 2019 17.41 / 955.84 2 73
7 13 1061.5 80 15.12 1109 1341 18.75 / 957.19 2 71
8 13 961.3 80 15.08 1032 1245 19.99 / 958.43 2 76
9 14 -0.1 118 15.23 401 721 20.72 / 959.15 2 101
Average= 18.81
(KJ/cycle)

Cycle 49 GMT 24/ 8/2019 8:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.8 128 15.20 425 827 0.83 / 917.38 2 36
2 6 5719.6 70 14.65 3857 3955 4.78 / 921.33 2 73
3 3 5369.4 9 14.83 3732 498 5.28 / 921.83 2 74
4 3 5224.0 1 14.98 3783 57 5.34 / 921.89 2 70
5 7 5269.5 80 14.76 3625 4280 9.62 / 926.17 2 74
6 13 4292.7 80 14.74 3063 3612 13.23 / 929.78 2 82
7 13 3026.2 80 14.89 2336 2783 16.01 / 932.56 2 82
8 13 1965.0 80 15.01 1682 2020 18.03 / 934.58 2 81
9 13 1128.4 80 15.11 1154 1395 19.43 / 935.98 2 76
10 13 925.8 80 15.09 1016 1227 20.65 / 937.20 2 79
11 13 188.7 80 15.21 528 642 21.30 / 937.84 2 74
12 14 -0.8 37 15.22 406 229 21.52 / 938.07 2 103
13 14 -0.7 63 15.20 380 364 21.89 / 938.44 16 244
Average= 18.77
(KJ/cycle)

Cycle 48 GMT 14/ 8/2019 6:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.9 122 15.19 425 788 0.79 / 895.55 2 33
2 6 5741.4 70 14.65 3874 3973 4.76 / 899.52 2 71
3 3 5488.6 16 14.78 3775 893 5.65 / 900.42 2 73
4 3 5218.0 1 14.99 3771 57 5.71 / 900.47 2 67
5 7 5266.9 80 14.77 3612 4268 9.98 / 904.74 2 74
6 13 4325.9 80 14.74 3075 3626 13.60 / 908.37 2 79
7 13 3048.1 80 14.88 2323 2765 16.37 / 911.13 2 77
8 13 1984.1 80 15.01 1687 2026 18.39 / 913.16 2 80
9 13 1159.6 80 15.11 1173 1418 19.81 / 914.57 2 78
10 13 945.8 80 15.09 1028 1241 21.05 / 915.82 2 77
11 14 0.0 123 15.24 391 733 21.79 / 916.55 2 117
Average= 18.71
(KJ/cycle)

Cycle 47 GMT 4/ 8/2019 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.7 126 15.20 409 783 0.78 / 875.16 2 32
2 6 5763.8 70 14.65 3902 4002 4.78 / 879.16 2 67
3 7 5052.8 80 14.79 3497 4138 8.92 / 883.30 2 73
4 13 4167.4 80 14.76 3000 3542 12.46 / 886.84 2 74
5 13 2873.2 80 14.91 2219 2647 15.11 / 889.49 2 76
6 13 1991.2 80 14.99 1704 2043 17.16 / 891.53 2 73
7 13 1090.4 80 15.11 1132 1368 18.52 / 892.90 2 71
8 13 878.1 80 15.10 985 1190 19.71 / 894.09 2 72
9 14 -0.3 113 15.23 390 671 20.38 / 894.76 2 114
Average= 18.64
(KJ/cycle)

Cycle 46 GMT 25/ 7/2019 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.6 131 15.20 416 828 0.83 / 855.23 2 35
2 6 5743.7 71 14.65 3877 4033 4.86 / 859.27 2 65
3 7 4969.5 80 14.81 3455 4093 8.95 / 863.36 2 71
4 13 4017.4 80 14.79 2886 3415 12.37 / 866.77 2 73
5 13 2838.6 80 14.91 2202 2627 15.00 / 869.40 2 75
6 13 1976.7 80 15.00 1678 2014 17.01 / 871.41 2 71
7 13 999.4 80 15.13 1067 1291 18.30 / 872.71 2 70
8 13 672.5 80 15.14 851 1031 19.33 / 873.74 2 68
9 14 -0.2 106 15.24 397 641 19.97 / 874.38 2 103
Average= 18.60
(KJ/cycle)

Cycle 45 GMT 15/ 7/2019 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.7 127 15.21 424 819 0.82 / 833.52 2 29
2 6 5740.1 70 14.66 3877 3979 4.80 / 837.50 2 64
3 3 5421.3 12 14.82 3736 664 5.46 / 838.17 2 67
4 3 5225.1 1 15.00 3740 56 5.52 / 838.22 2 67
5 7 5270.7 80 14.77 3619 4276 9.79 / 842.50 2 69
6 13 4221.5 80 14.77 3032 3583 13.38 / 846.08 2 73
7 13 3026.2 80 14.90 2330 2777 16.15 / 848.86 2 72
8 13 1996.2 80 15.01 1707 2050 18.20 / 850.91 2 74
9 13 1210.5 80 15.10 1218 1471 19.68 / 852.38 2 70
10 13 997.7 80 15.08 1071 1292 20.97 / 853.67 2 73
11 14 -0.5 121 15.24 397 732 21.70 / 854.40 2 102
Average= 18.57
(KJ/cycle)

Cycle 44 GMT 4/ 7/2019 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.5 127 15.19 417 804 0.80 / 812.70 2 30
2 6 5756.6 70 14.65 3892 3991 4.80 / 816.70 2 66
3 3 5219.0 1 14.95 3779 56 4.85 / 816.75 2 61
4 7 5222.8 80 14.78 3588 4242 9.09 / 820.99 2 69
5 13 4243.6 80 14.77 3036 3587 12.68 / 824.58 2 73
6 13 2936.6 80 14.92 2253 2689 15.37 / 827.27 2 74
7 13 1960.3 80 15.03 1670 2008 17.38 / 829.28 2 71
8 13 1206.0 80 15.11 1196 1446 18.82 / 830.72 2 71
9 13 996.9 80 15.09 1053 1271 20.10 / 832.00 2 76
10 14 -0.2 118 15.25 394 709 20.81 / 832.71 2 108
Average= 18.50
(KJ/cycle)

Cycle 43 GMT 24/ 6/2019 21: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.1 139 15.22 415 878 0.88 / 793.08 2 29
2 6 5753.8 70 14.67 3893 3998 4.88 / 797.07 2 72
3 7 4641.8 80 14.86 3242 3854 8.73 / 800.93 2 75
4 13 3769.3 80 14.83 2765 3280 12.01 / 804.21 2 79
5 13 2661.0 80 14.95 2095 2506 14.52 / 806.71 2 76
6 13 1967.3 80 15.00 1663 1996 16.51 / 808.71 2 78
7 13 998.2 80 15.13 1066 1290 17.80 / 810.00 2 73
8 13 445.0 80 15.19 699 849 18.65 / 810.85 2 69
9 13 21.7 80 15.25 404 493 19.14 / 811.34 2 86
10 14 -0.2 16 15.24 391 95 19.24 / 811.44 2 117
11 14 -0.2 84 15.22 361 462 19.70 / 811.90 19 244
Average= 18.45
(KJ/cycle)

Cycle 42 GMT 14/ 6/2019 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.9 140 15.15 383 812 0.81 / 772.30 2 29
2 6 5746.4 70 14.67 3874 3978 4.79 / 776.28 2 70
3 3 5228.2 1 14.98 3804 57 4.85 / 776.33 2 66
4 7 5198.7 80 14.80 3566 4222 9.07 / 780.56 2 74
5 13 4163.3 80 14.79 2993 3541 12.61 / 784.10 2 77
6 13 3036.9 80 14.91 2318 2765 15.38 / 786.86 2 80
7 13 1971.9 80 15.03 1684 2025 17.40 / 788.89 2 80
8 13 1120.8 80 15.13 1154 1397 18.80 / 790.28 2 79
9 13 917.3 80 15.12 1006 1217 20.01 / 791.50 2 79
10 14 0.0 116 15.26 395 699 20.71 / 792.20 2 108
Average= 18.42
(KJ/cycle)

Cycle 41 GMT 4/ 6/2019 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 7 16.9 80 15.24 392 478 0.48 / 767.23 2 30
2 13 65.9 80 15.22 413 503 0.98 / 767.74 2 33
3 13 119.5 80 15.20 435 529 1.51 / 768.27 2 35
4 13 191.0 80 15.18 466 566 2.08 / 768.83 2 33
5 13 266.8 80 15.17 510 619 2.69 / 769.45 2 37
6 13 235.8 80 15.17 487 591 3.29 / 770.04 2 40
7 13 146.2 80 15.17 428 519 3.81 / 770.56 2 41
8 13 22.9 80 15.18 355 431 4.24 / 770.99 2 47
9 14 -0.5 30 15.18 343 156 4.39 / 771.15 2 103
10 14 -0.7 70 15.16 318 337 4.73 / 771.49 14 244
Average= 18.37
(KJ/cycle)

Cycle 40 GMT 4/ 6/2019 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.9 138 15.22 418 878 0.88 / 746.49 2 33
2 6 5607.0 70 14.69 3787 3894 4.77 / 750.38 2 67
3 3 5259.2 3 14.99 3754 169 4.94 / 750.55 2 66
4 3 5220.7 1 15.04 3755 56 5.00 / 750.61 2 68
5 7 5278.7 80 14.79 3619 4282 9.28 / 754.89 2 74
6 13 4258.0 80 14.79 3039 3596 12.88 / 758.48 2 75
7 13 2969.4 80 14.94 2270 2713 15.59 / 761.20 2 75
8 13 1980.2 80 15.04 1689 2032 17.62 / 763.23 2 83
9 13 1299.9 80 15.10 1267 1531 19.15 / 764.76 2 81
10 13 983.0 80 15.11 1061 1283 20.43 / 766.04 2 85
11 14 -0.1 117 15.26 400 714 21.15 / 766.76 2 106
Average= 18.70
(KJ/cycle)

Cycle 39 GMT 25/ 5/2019 11:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.3 140 15.23 416 887 0.89 / 725.79 2 29
2 6 5768.4 70 14.67 3893 3998 4.88 / 729.79 2 69
3 7 5184.7 80 14.81 3577 4238 9.12 / 734.03 2 70
4 13 4330.7 80 14.79 3069 3631 12.75 / 737.66 2 76
5 13 2877.1 80 14.95 2229 2666 15.42 / 740.32 2 76
6 13 1957.1 80 15.04 1672 2012 17.43 / 742.34 2 76
7 13 1082.2 80 15.15 1134 1374 18.81 / 743.71 2 72
8 13 867.7 80 15.13 985 1192 20.00 / 744.90 2 73
9 14 -0.4 116 15.26 399 706 20.70 / 745.61 2 112
Average= 18.64
(KJ/cycle)

Cycle 38 GMT 15/ 5/2019 9:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.7 143 15.22 407 886 0.89 / 705.24 2 26
2 6 5748.2 70 14.68 3883 3990 4.88 / 709.23 2 66
3 7 5106.0 80 14.81 3540 4194 9.07 / 713.43 2 71
4 13 4245.3 80 14.80 3021 3577 12.65 / 717.01 2 72
5 13 2883.2 80 14.95 2237 2675 15.32 / 719.68 2 76
6 13 1979.6 80 15.04 1689 2032 17.35 / 721.71 2 74
7 13 1015.7 80 15.16 1079 1309 18.66 / 723.02 2 72
8 13 912.9 80 15.13 1002 1213 19.88 / 724.23 2 74
9 14 -0.7 110 15.27 398 669 20.54 / 724.90 2 114
Average= 18.59
(KJ/cycle)

Cycle 37 GMT 5/ 5/2019 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.6 143 15.20 406 882 0.88 / 683.86 2 26
2 6 5726.7 70 14.68 3863 3970 4.85 / 687.83 2 68
3 3 5233.3 1 14.96 3859 58 4.91 / 687.89 2 63
4 7 5256.5 80 14.80 3618 4284 9.19 / 692.17 2 70
5 13 4246.8 80 14.81 3027 3586 12.78 / 695.76 2 73
6 13 3113.4 80 14.92 2354 2810 15.59 / 698.57 2 74
7 13 1951.9 80 15.06 1665 2006 17.60 / 700.57 2 73
8 13 1256.8 80 15.12 1237 1496 19.09 / 702.07 2 73
9 13 928.8 80 15.13 1020 1235 20.33 / 703.30 2 72
10 13 7.7 80 15.28 398 487 20.81 / 703.79 2 55
11 14 -0.7 37 15.26 388 219 21.03 / 704.01 2 107
12 14 -0.8 63 15.25 363 349 21.38 / 704.36 13 244
Average= 18.54
(KJ/cycle)

Cycle 36 GMT 25/ 4/2019 5:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.9 141 15.21 406 871 0.87 / 661.73 2 27
2 6 5747.2 71 14.68 3864 4027 4.90 / 665.76 2 67
3 3 5307.2 6 14.88 3683 329 5.23 / 666.09 2 69
4 7 5219.9 80 14.81 3591 4255 9.48 / 670.35 2 72
5 13 4410.7 80 14.79 3124 3696 13.18 / 674.04 2 76
6 13 2946.5 80 14.95 2270 2715 15.89 / 676.76 2 77
7 13 1982.4 80 15.05 1682 2025 17.92 / 678.78 2 75
8 13 1196.7 80 15.14 1193 1445 19.36 / 680.23 2 75
9 13 986.0 80 15.12 1054 1275 20.64 / 681.50 2 76
10 13 17.7 80 15.28 405 495 21.13 / 682.00 2 67
11 13 3.9 80 15.26 375 458 21.59 / 682.45 2 244
12 14 -0.5 1 15.26 392 6 21.60 / 682.46 63 158
13 14 -0.5 99 15.24 343 518 22.11 / 682.98 68 244
Average= 18.46
(KJ/cycle)

Cycle 35 GMT 15/ 4/2019 4: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.4 141 15.23 413 887 0.89 / 639.80 2 26
2 6 5748.1 70 14.68 3891 3998 4.89 / 643.80 2 69
3 3 5252.1 3 14.97 3814 171 5.06 / 643.97 2 67
4 7 5253.2 80 14.80 3609 4273 9.33 / 648.25 2 72
5 13 4409.5 80 14.80 3108 3680 13.01 / 651.93 2 79
6 13 3120.8 80 14.93 2357 2815 15.82 / 654.74 2 78
7 13 1952.1 80 15.07 1666 2009 17.83 / 656.75 2 78
8 13 1120.1 80 15.16 1142 1385 19.22 / 658.13 2 76
9 13 915.4 80 15.15 1009 1223 20.44 / 659.36 2 76
10 13 28.1 80 15.29 415 508 20.95 / 659.86 2 66
11 13 16.1 80 15.27 383 468 21.42 / 660.33 2 244
12 14 -0.6 1 15.27 400 6 21.42 / 660.34 57 161
13 14 -0.7 99 15.24 348 525 21.95 / 660.86 64 244
Average= 18.36
(KJ/cycle)

Cycle 34 GMT 5/ 4/2019 1:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 74.0 135 15.25 418 861 0.86 / 617.53 2 25
2 6 5750.8 70 14.69 3878 3988 4.85 / 621.52 2 66
3 3 5471.2 15 14.82 3806 846 5.69 / 622.36 2 70
4 7 5295.9 80 14.80 3635 4304 10.00 / 626.67 2 73
5 13 4290.2 80 14.82 3055 3622 13.62 / 630.29 2 77
6 13 3068.7 80 14.94 2334 2790 16.41 / 633.08 2 78
7 13 1955.4 80 15.07 1674 2018 18.43 / 635.10 2 79
8 13 1267.1 80 15.13 1239 1500 19.93 / 636.60 2 77
9 13 964.2 80 15.14 1037 1256 21.18 / 637.85 2 78
10 13 18.2 80 15.29 403 493 21.68 / 638.35 2 54
11 14 -1.2 33 15.28 389 196 21.87 / 638.54 2 100
12 14 -1.2 67 15.26 365 373 22.25 / 638.92 19 244
Average= 18.25
(KJ/cycle)

Cycle 33 GMT 26/ 3/2019 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.5 137 15.25 402 840 0.84 / 597.01 2 25
2 6 5719.4 70 14.69 3861 3970 4.81 / 600.98 2 66
3 7 5168.0 80 14.82 3563 4224 9.03 / 605.21 2 71
4 13 4181.5 80 14.84 3005 3568 12.60 / 608.78 2 76
5 13 2940.9 80 14.97 2263 2710 15.31 / 611.49 2 83
6 13 1959.9 80 15.07 1673 2017 17.33 / 613.50 2 79
7 13 997.6 80 15.19 1067 1297 18.63 / 614.80 2 77
8 13 889.8 80 15.15 989 1199 19.82 / 616.00 2 79
9 14 -0.2 112 15.29 392 671 20.50 / 616.67 2 108
Average= 18.14
(KJ/cycle)

Cycle 32 GMT 15/ 3/2019 22: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.0 142 15.26 407 882 0.88 / 576.77 2 26
2 6 5719.4 70 14.70 3856 3968 4.85 / 580.74 2 81
3 7 5034.5 80 14.84 3481 4133 8.98 / 584.87 2 84
4 13 4057.2 80 14.86 2940 3495 12.48 / 588.36 2 87
5 13 2687.0 80 15.01 2118 2543 15.02 / 590.91 2 87
6 13 1938.8 80 15.07 1662 2004 17.02 / 592.91 2 86
7 13 1088.0 80 15.17 1131 1373 18.40 / 594.28 2 84
8 13 984.9 80 15.13 1048 1268 19.67 / 595.55 2 87
9 14 -1.2 103 15.29 395 622 20.29 / 596.17 2 105
Average= 18.07
(KJ/cycle)

Cycle 31 GMT 5/ 3/2019 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.7 141 15.25 405 871 0.87 / 555.73 2 27
2 6 5743.5 70 14.70 3882 3995 4.87 / 559.72 2 75
3 3 5242.1 2 14.99 3823 115 4.98 / 559.84 2 70
4 7 5283.6 80 14.82 3634 4308 9.29 / 564.14 2 79
5 13 4174.0 80 14.84 3006 3569 12.86 / 567.71 2 81
6 13 3217.7 80 14.92 2429 2899 15.76 / 570.61 2 81
7 13 1974.3 80 15.08 1686 2034 17.79 / 572.65 2 81
8 13 1125.1 80 15.17 1151 1397 19.19 / 574.04 2 81
9 13 802.7 80 15.18 937 1138 20.33 / 575.18 2 81
10 14 0.3 117 15.30 394 705 21.03 / 575.89 2 106
Average= 18.00
(KJ/cycle)

Cycle 30 GMT 23/ 2/2019 17:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.3 139 15.26 414 878 0.88 / 533.77 2 26
2 6 5804.9 70 14.69 3928 4039 4.92 / 537.80 2 78
3 3 5292.7 5 14.93 3753 280 5.20 / 538.08 2 78
4 7 5278.9 80 14.82 3641 4317 9.51 / 542.40 2 79
5 13 4308.7 80 14.83 3080 3654 13.17 / 546.06 2 83
6 13 3131.9 80 14.94 2400 2868 16.04 / 548.92 2 87
7 13 1978.9 80 15.08 1706 2058 18.09 / 550.98 2 83
8 13 1296.2 80 15.14 1269 1537 19.63 / 552.52 2 84
9 13 977.9 80 15.15 1053 1276 20.91 / 553.80 2 83
10 13 14.4 80 15.31 403 494 21.40 / 554.29 2 59
11 14 -0.5 33 15.29 390 197 21.60 / 554.49 2 105
12 14 -0.4 67 15.27 362 370 21.97 / 554.86 14 244
Average= 17.90
(KJ/cycle)

Cycle 29 GMT 13/ 2/2019 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.3 142 15.24 404 874 0.87 / 512.93 2 26
2 6 5676.2 70 14.71 3851 3965 4.84 / 516.90 2 67
3 7 5123.7 80 14.84 3545 4209 9.05 / 521.10 2 73
4 13 4101.7 80 14.87 2947 3506 12.55 / 524.61 2 75
5 13 3163.9 80 14.93 2387 2851 15.41 / 527.46 2 79
6 13 1972.6 80 15.08 1687 2035 17.44 / 529.50 2 78
7 13 1257.9 80 15.15 1233 1494 18.93 / 530.99 2 79
8 13 932.2 80 15.16 1018 1235 20.17 / 532.23 2 81
9 14 -0.5 110 15.30 393 661 20.83 / 532.89 2 112
Average= 17.76
(KJ/cycle)

Cycle 28 GMT 3/ 2/2019 14:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 72.3 137 15.27 420 879 0.88 / 490.68 2 25
2 6 5655.9 70 14.72 3842 3959 4.84 / 494.64 2 68
3 3 5417.0 12 14.87 3778 674 5.51 / 495.31 2 67
4 7 5293.0 80 14.82 3642 4318 9.83 / 499.63 2 70
5 13 4447.5 80 14.82 3141 3724 13.55 / 503.36 2 75
6 13 3051.0 80 14.97 2334 2795 16.35 / 506.15 2 75
7 13 1980.6 80 15.09 1687 2037 18.39 / 508.19 2 77
8 13 1210.6 80 15.17 1208 1466 19.85 / 509.65 2 76
9 13 768.4 80 15.20 914 1111 20.96 / 510.76 2 72
10 13 276.9 80 15.26 578 706 21.67 / 511.47 2 82
11 14 -1.1 37 15.29 403 228 21.90 / 511.70 2 114
12 14 -1.2 63 15.28 372 358 22.25 / 512.06 24 244
Average= 17.66
(KJ/cycle)

Cycle 27 GMT 24/ 1/2019 13:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.3 140 15.26 407 870 0.87 / 470.16 2 25
2 6 5663.4 70 14.72 3837 3954 4.82 / 474.11 2 67
3 7 5137.6 80 14.84 3556 4222 9.04 / 478.33 2 72
4 13 4170.7 80 14.87 2984 3550 12.59 / 481.88 2 76
5 13 2974.2 80 14.98 2298 2754 15.35 / 484.64 2 76
6 13 1993.4 80 15.08 1698 2048 17.40 / 486.69 2 76
7 13 1010.7 80 15.21 1086 1321 18.72 / 488.01 2 73
8 13 796.8 80 15.20 939 1142 19.86 / 489.15 2 73
9 14 -0.6 108 15.31 395 653 20.51 / 489.80 2 105
Average= 17.49
(KJ/cycle)

Cycle 26 GMT 14/ 1/2019 12:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.8 137 15.29 413 865 0.87 / 448.23 2 23
2 6 5718.9 70 14.72 3862 3979 4.84 / 452.21 2 65
3 3 5352.1 8 14.90 3722 444 5.29 / 452.65 2 65
4 7 5276.8 80 14.83 3622 4297 9.59 / 456.95 2 70
5 13 4320.6 80 14.85 3077 3655 13.24 / 460.60 2 75
6 13 3065.8 80 14.97 2346 2810 16.05 / 463.41 2 74
7 13 1992.9 80 15.09 1705 2058 18.11 / 465.47 2 74
8 13 1229.5 80 15.17 1234 1498 19.61 / 466.97 2 75
9 13 899.6 80 15.18 1012 1229 20.84 / 468.20 2 73
10 13 18.0 80 15.32 412 505 21.34 / 468.70 2 65
11 14 -0.5 35 15.30 397 213 21.55 / 468.92 2 105
12 14 -0.4 65 15.29 376 374 21.93 / 469.29 15 244
Average= 17.38
(KJ/cycle)

Cycle 25 GMT 4/ 1/2019 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.3 138 15.29 404 852 0.85 / 427.26 2 25
2 6 5712.0 70 14.73 3869 3989 4.84 / 431.25 2 67
3 7 5218.6 80 14.84 3601 4275 9.12 / 435.52 2 68
4 13 4401.9 80 14.84 3134 3721 12.84 / 439.24 2 74
5 13 3007.8 80 14.99 2321 2783 15.62 / 442.02 2 73
6 13 1985.7 80 15.10 1703 2057 17.68 / 444.08 2 72
7 13 1050.2 80 15.21 1109 1349 19.03 / 445.43 2 68
8 13 951.5 80 15.18 1036 1258 20.29 / 446.69 2 72
9 14 -0.6 112 15.32 392 673 20.96 / 447.36 2 101
Average= 17.21
(KJ/cycle)

Cycle 24 GMT 25/12/2018 8:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.9 139 15.29 412 876 0.88 / 406.75 2 26
2 6 5691.7 70 14.74 3845 3967 4.84 / 410.71 2 65
3 7 5207.9 80 14.85 3583 4257 9.10 / 414.97 2 71
4 13 4138.3 80 14.89 2976 3545 12.64 / 418.51 2 75
5 13 3037.5 80 14.98 2329 2791 15.44 / 421.31 2 75
6 13 1949.7 80 15.11 1676 2026 17.46 / 423.33 2 76
7 13 991.7 80 15.23 1073 1307 18.77 / 424.64 2 71
8 13 775.7 80 15.22 922 1123 19.89 / 425.76 2 68
9 14 -0.7 108 15.33 388 642 20.53 / 426.40 2 105
Average= 17.06
(KJ/cycle)

Cycle 23 GMT 15/12/2018 6:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.8 141 15.29 411 886 0.89 / 386.24 2 28
2 6 5588.5 70 14.75 3807 3931 4.82 / 390.17 2 66
3 7 5156.5 80 14.86 3554 4225 9.04 / 394.39 2 71
4 13 4098.6 80 14.89 2957 3522 12.56 / 397.91 2 75
5 13 2981.1 80 14.99 2302 2761 15.32 / 400.67 2 74
6 13 1971.3 80 15.10 1682 2032 17.36 / 402.71 2 74
7 13 1105.5 80 15.21 1141 1388 18.74 / 404.09 2 72
8 13 785.8 80 15.22 928 1130 19.87 / 405.22 2 70
9 14 -0.5 108 15.33 390 646 20.52 / 405.87 2 105
Average= 16.91
(KJ/cycle)

Cycle 22 GMT 5/12/2018 4:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.9 141 15.30 417 900 0.90 / 364.81 2 29
2 6 5743.9 70 14.73 3883 4004 4.90 / 368.81 2 67
3 3 5247.7 2 15.02 3821 115 5.02 / 368.93 2 64
4 7 5275.7 80 14.85 3638 4322 9.34 / 373.25 2 72
5 13 4302.2 80 14.87 3075 3658 13.00 / 376.91 2 77
6 13 3158.6 80 14.97 2405 2880 15.88 / 379.79 2 75
7 13 1978.4 80 15.12 1699 2055 17.93 / 381.84 2 76
8 13 1283.2 80 15.18 1268 1540 19.47 / 383.38 2 76
9 13 955.8 80 15.18 1045 1269 20.74 / 384.65 2 74
10 14 -0.5 116 15.33 393 699 21.44 / 385.35 2 105
Average= 16.75
(KJ/cycle)

Cycle 21 GMT 25/11/2018 2:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 72.7 139 15.30 421 895 0.90 / 343.50 2 29
2 6 5551.7 70 14.76 3782 3908 4.80 / 347.40 2 67
3 3 5262.8 3 15.01 3901 176 4.98 / 347.58 2 65
4 7 5296.2 80 14.86 3644 4332 9.31 / 351.91 2 70
5 13 4372.1 80 14.86 3133 3725 13.04 / 355.63 2 74
6 13 2985.3 80 15.01 2305 2768 15.80 / 358.40 2 73
7 13 1960.2 80 15.12 1676 2027 17.83 / 360.43 2 82
8 13 1272.1 80 15.19 1258 1529 19.36 / 361.96 2 84
9 13 949.1 80 15.19 1043 1267 20.63 / 363.23 2 84
10 14 -0.3 114 15.34 390 682 21.31 / 363.91 2 105
Average= 16.54
(KJ/cycle)

Cycle 20 GMT 15/11/2018 0:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.6 143 15.31 415 909 0.91 / 322.86 2 30
2 6 5620.0 70 14.77 3813 3942 4.85 / 326.80 2 67
3 7 5085.5 80 14.88 3541 4215 9.07 / 331.02 2 70
4 13 4185.5 80 14.89 3015 3591 12.66 / 334.61 2 73
5 13 2861.7 80 15.03 2243 2697 15.35 / 337.31 2 73
6 13 1929.2 80 15.12 1671 2021 17.38 / 339.33 2 74
7 13 1064.6 80 15.22 1128 1373 18.75 / 340.70 2 71
8 13 957.8 80 15.19 1042 1266 20.02 / 341.97 2 74
9 14 -0.7 103 15.34 400 632 20.65 / 342.60 2 101
Average= 16.31
(KJ/cycle)

Cycle 19 GMT 4/11/2018 23:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.9 135 15.31 431 891 0.89 / 301.08 2 29
2 6 5614.0 70 14.76 3833 3960 4.85 / 305.04 2 67
3 3 5383.9 10 14.93 3763 562 5.41 / 305.60 2 66
4 7 5306.1 80 14.86 3670 4363 9.78 / 309.97 2 69
5 13 4380.5 80 14.87 3142 3738 13.51 / 313.70 2 73
6 13 2963.1 80 15.02 2296 2759 16.27 / 316.46 2 72
7 13 1949.7 80 15.13 1675 2027 18.30 / 318.49 2 74
8 13 1196.5 80 15.21 1213 1476 19.78 / 319.97 2 72
9 13 977.7 80 15.19 1065 1294 21.07 / 321.26 2 73
10 14 -0.1 114 15.35 395 691 21.76 / 321.95 2 110
Average= 16.10
(KJ/cycle)

Cycle 18 GMT 25/10/2018 13:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.0 135 15.32 425 879 0.88 / 279.93 2 31
2 6 5601.1 70 14.78 3816 3948 4.83 / 283.88 2 67
3 7 5271.1 80 14.88 3647 4341 9.17 / 288.22 2 69
4 13 4246.7 80 14.90 3052 3638 12.81 / 291.86 2 72
5 13 3148.2 80 14.99 2410 2890 15.70 / 294.75 2 72
6 13 1964.7 80 15.13 1695 2052 17.75 / 296.80 2 74
7 13 1196.8 80 15.21 1216 1480 19.23 / 298.28 2 72
8 13 874.2 80 15.22 1001 1219 20.45 / 299.50 2 71
9 14 -0.7 112 15.35 403 693 21.14 / 300.19 2 100
Average= 15.80
(KJ/cycle)

Cycle 17 GMT 15/10/2018 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.3 134 15.32 432 887 0.89 / 258.54 2 32
2 6 5663.8 70 14.78 3860 3994 4.88 / 262.53 2 66
3 3 5245.8 2 15.06 3779 114 4.99 / 262.64 2 61
4 7 5272.2 80 14.88 3644 4338 9.33 / 266.98 2 70
5 13 4434.5 80 14.87 3160 3759 13.09 / 270.74 2 72
6 13 3025.1 80 15.02 2329 2799 15.89 / 273.54 2 72
7 13 1996.5 80 15.13 1706 2065 17.95 / 275.60 2 75
8 13 1296.0 80 15.20 1279 1555 19.51 / 277.16 2 74
9 13 859.7 80 15.23 991 1207 20.72 / 278.37 2 72
10 14 -0.2 112 15.36 399 686 21.40 / 279.05 2 106
Average= 15.50
(KJ/cycle)

Cycle 16 GMT 4/10/2018 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.4 132 15.33 427 864 0.86 / 237.31 2 35
2 6 5630.8 69 14.79 3830 3909 4.77 / 241.22 2 70
3 3 5258.7 3 15.07 3802 172 4.94 / 241.39 2 65
4 7 5309.1 80 14.89 3666 4367 9.31 / 245.75 2 74
5 13 4194.9 80 14.92 3018 3602 12.91 / 249.36 2 78
6 13 3105.7 80 15.01 2380 2858 15.77 / 252.21 2 78
7 13 1995.2 80 15.14 1699 2058 17.83 / 254.27 2 80
8 13 1128.9 80 15.24 1169 1425 19.25 / 255.70 2 78
9 13 921.3 80 15.22 1030 1254 20.51 / 256.95 2 78
10 14 0.1 112 15.36 405 697 21.21 / 257.65 2 106
Average= 15.16
(KJ/cycle)

Cycle 15 GMT 24/ 9/2018 8:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.0 136 15.34 425 887 0.89 / 216.74 2 33
2 6 5484.0 69 14.81 3744 3826 4.71 / 220.56 2 67
3 7 5189.2 80 14.91 3597 4291 9.00 / 224.85 2 72
4 13 4099.9 80 14.94 2959 3537 12.54 / 228.39 2 73
5 13 2971.4 80 15.04 2301 2769 15.31 / 231.16 2 73
6 13 1943.6 80 15.15 1672 2026 17.33 / 233.19 2 74
7 13 1019.1 80 15.26 1099 1342 18.68 / 234.53 2 70
8 13 918.8 80 15.23 1023 1246 19.92 / 235.77 2 72
9 14 -0.3 108 15.37 403 669 20.59 / 236.44 2 117
Average= 14.78
(KJ/cycle)

Cycle 14 GMT 13/ 9/2018 23:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.5 137 15.34 422 887 0.89 / 195.91 2 32
2 6 5614.3 70 14.80 3821 3959 4.85 / 199.87 2 67
3 7 5223.9 80 14.91 3622 4320 9.17 / 204.19 2 70
4 13 4329.3 80 14.91 3096 3693 12.86 / 207.88 2 72
5 13 2977.8 80 15.04 2295 2761 15.62 / 210.64 2 73
6 13 1955.6 80 15.16 1671 2027 17.65 / 212.67 2 75
7 13 981.3 80 15.28 1066 1303 18.95 / 213.97 2 69
8 13 880.9 80 15.25 990 1208 20.16 / 215.18 2 72
9 14 0.0 110 15.38 396 670 20.83 / 215.85 2 106
Average= 14.39
(KJ/cycle)

Cycle 13 GMT 3/ 9/2018 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.8 132 15.35 428 867 0.87 / 174.28 2 32
2 6 5657.9 70 14.81 3844 3985 4.85 / 178.27 2 66
3 3 5306.3 6 15.00 3736 336 5.19 / 178.60 2 66
4 7 5317.8 80 14.91 3677 4386 9.57 / 182.99 2 71
5 13 4500.6 80 14.88 3200 3809 13.38 / 186.80 2 74
6 13 3154.8 80 15.02 2412 2898 16.28 / 189.70 2 75
7 13 1969.3 80 15.16 1697 2058 18.34 / 191.75 2 75
8 13 1135.2 80 15.25 1167 1424 19.76 / 193.18 2 77
9 13 819.2 80 15.26 956 1167 20.93 / 194.34 2 75
10 14 0.2 112 15.38 394 679 21.61 / 195.02 2 110
Average= 13.93
(KJ/cycle)

Cycle 12 GMT 24/ 8/2018 4:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.0 130 15.34 441 879 0.88 / 152.95 2 31
2 6 5674.3 70 14.81 3854 3995 4.87 / 156.95 2 63
3 3 5252.9 3 15.09 3835 174 5.05 / 157.12 2 63
4 7 5277.4 80 14.93 3637 4344 9.39 / 161.47 2 69
5 13 4438.1 80 14.90 3145 3749 13.14 / 165.22 2 72
6 13 3008.4 80 15.06 2317 2792 15.93 / 168.01 2 73
7 13 1992.1 80 15.16 1703 2065 18.00 / 170.07 2 75
8 13 1073.2 80 15.27 1129 1379 19.38 / 171.45 2 71
9 13 970.9 80 15.24 1053 1284 20.66 / 172.74 2 74
10 14 -0.2 110 15.38 401 678 21.34 / 173.41 2 104
Average= 13.34
(KJ/cycle)

Cycle 11 GMT 19/ 8/2018 4:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.7 142 15.35 438 955 0.95 / 132.61 2 32
2 6 5504.6 64 14.84 3767 3578 4.53 / 136.18 2 67
3 3 5042.9 2 15.11 3678 111 4.64 / 136.30 2 64
4 7 5080.3 80 14.96 3530 4225 8.87 / 140.52 2 70
5 13 4109.7 80 14.95 2970 3552 12.42 / 144.07 2 73
6 13 3010.2 80 15.05 2320 2793 15.21 / 146.87 2 72
7 13 1963.2 80 15.16 1683 2041 17.25 / 148.91 2 75
8 13 969.3 80 15.29 1070 1309 18.56 / 150.22 2 70
9 13 862.4 80 15.25 987 1204 19.77 / 151.42 2 73
10 14 0.1 104 15.38 409 654 20.42 / 152.07 2 109
Average= 12.67
(KJ/cycle)

Cycle 10 GMT 14/ 8/2018 6:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.9 140 15.36 433 931 0.93 / 112.14 2 33
2 6 5503.7 64 14.85 3777 3590 4.52 / 115.73 2 68
3 3 5077.8 4 15.07 3590 216 4.74 / 115.95 2 68
4 7 5056.0 80 14.96 3524 4218 8.95 / 120.17 2 71
5 13 4397.0 80 14.92 3133 3740 12.69 / 123.90 2 74
6 13 2725.7 80 15.11 2142 2589 15.28 / 126.49 2 74
7 13 1957.0 80 15.17 1684 2044 17.33 / 128.54 2 76
8 13 999.9 80 15.29 1079 1320 18.65 / 129.86 2 72
9 13 786.3 80 15.28 935 1143 19.79 / 131.00 2 72
10 14 -0.1 103 15.39 411 652 20.44 / 131.65 2 114
Average= 11.97
(KJ/cycle)

Cycle 9 GMT 9/ 8/2018 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.3 164 15.35 432 1088 1.09 / 94.06 2 35
2 6 5007.5 62 14.90 3496 3230 4.32 / 97.29 2 72
3 3 4569.7 3 15.17 3435 156 4.47 / 97.44 2 70
4 7 4489.8 80 15.00 3212 3854 8.33 / 101.30 2 77
5 13 3596.8 80 15.01 2684 3223 11.55 / 104.52 2 77
6 13 2548.3 80 15.11 2050 2478 14.03 / 107.00 2 79
7 13 1519.2 80 15.23 1424 1735 15.76 / 108.73 2 80
8 13 923.8 80 15.28 1036 1266 17.03 / 110.00 2 78
9 13 116.2 80 15.40 485 598 17.63 / 110.60 2 59
10 14 -0.2 65 15.40 400 400 18.03 / 111.00 2 101
11 14 -0.2 35 15.38 395 213 18.24 / 111.21 13 244
Average= 11.12
(KJ/cycle)

Cycle 8 GMT 7/ 8/2018 5:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.2 157 15.36 435 1049 1.05 / 75.32 2 35
2 6 5008.1 63 14.90 3495 3281 4.33 / 78.60 2 71
3 3 4631.3 7 15.07 3337 352 4.68 / 78.95 2 71
4 3 4531.3 1 15.22 3367 51 4.73 / 79.00 2 71
5 7 4545.4 80 14.99 3228 3871 8.60 / 82.87 2 76
6 13 3571.5 80 15.02 2655 3190 11.79 / 86.06 2 78
7 13 2451.1 80 15.14 1983 2402 14.20 / 88.46 2 79
8 13 1615.9 80 15.21 1484 1806 16.00 / 90.27 2 79
9 13 931.6 80 15.28 1048 1281 17.28 / 91.55 2 77
10 13 343.4 80 15.36 645 793 18.08 / 92.34 2 70
11 14 0.0 75 15.39 410 473 18.55 / 92.82 2 108
12 14 0.0 25 15.38 396 152 18.70 / 92.97 16 244
Average= 10.33
(KJ/cycle)

Cycle 7 GMT 5/ 8/2018 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.0 211 15.34 441 1427 1.43 / 61.26 2 35
2 6 4005.4 60 15.01 2900 2612 4.04 / 63.88 2 71
3 3 3579.0 4 15.17 2744 167 4.21 / 64.04 2 74
4 7 3417.4 80 15.11 2564 3099 7.31 / 67.14 2 75
5 13 2484.8 80 15.17 2005 2433 9.74 / 69.57 2 78
6 13 1851.5 80 15.19 1622 1971 11.71 / 71.55 2 81
7 13 976.2 80 15.29 1079 1320 13.03 / 72.87 2 77
8 13 315.6 80 15.38 626 770 13.80 / 73.64 2 68
9 14 -0.2 97 15.40 411 614 14.41 / 74.25 2 110
10 14 -0.3 3 15.39 409 19 14.43 / 74.27 21 68
Average= 9.28
(KJ/cycle)

Cycle 6 GMT 3/ 8/2018 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.3 203 15.34 432 1345 1.35 / 45.95 2 37
2 6 4005.9 60 15.01 2904 2615 3.96 / 48.57 2 72
3 3 3688.1 10 15.12 2789 422 4.38 / 48.99 2 73
4 7 3517.3 80 15.09 2636 3182 7.56 / 52.17 2 77
5 13 2666.8 80 15.13 2119 2565 10.13 / 54.74 2 78
6 13 1809.9 80 15.20 1610 1958 12.09 / 56.69 2 81
7 13 986.2 80 15.29 1088 1331 13.42 / 58.02 2 76
8 13 770.2 80 15.28 937 1145 14.56 / 59.17 2 76
9 14 -0.2 105 15.39 413 667 15.23 / 59.84 2 102
Average= 8.55
(KJ/cycle)

Cycle 5 GMT 2/ 8/2018 1: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.9 179 15.40 403 1111 1.11 / 29.88 2 34
2 6 4009.3 59 15.01 2911 2578 3.69 / 32.45 2 67
3 3 4044.0 30 15.02 2978 1342 5.03 / 33.79 2 70
4 3 3621.0 6 15.15 2778 253 5.28 / 34.05 2 74
5 7 3487.3 80 15.09 2623 3166 8.45 / 37.21 2 76
6 13 2578.0 80 15.14 2071 2508 10.96 / 39.72 2 78
7 13 1817.2 80 15.19 1614 1961 12.92 / 41.68 2 80
8 13 978.3 80 15.28 1085 1326 14.25 / 43.01 2 76
9 13 536.1 80 15.32 786 963 15.21 / 43.97 2 71
10 14 0.1 101 15.39 407 633 15.84 / 44.61 2 109
Average= 7.43
(KJ/cycle)

Cycle 4 GMT 31/ 7/2018 12:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.1 373 15.37 407 2333 2.33 / 25.69 2 34
2 6 1007.1 57 15.31 1025 894 3.23 / 26.59 2 55
3 3 835.3 11 15.35 953 161 3.39 / 26.75 2 52
4 3 649.4 2 15.40 885 27 3.42 / 26.77 2 51
5 7 210.8 80 15.48 518 641 4.06 / 27.41 2 44
6 13 177.4 80 15.46 489 605 4.66 / 28.02 2 47
7 14 -0.1 132 15.45 365 744 5.41 / 28.76 2 106
Average= 5.75
(KJ/cycle)

Cycle 3 GMT 31/ 7/2018 2:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.0 375 15.37 401 2311 2.31 / 20.26 2 31
2 6 1003.2 57 15.31 1020 890 3.20 / 21.15 2 52
3 3 811.2 10 15.36 932 143 3.34 / 21.30 2 54
4 3 640.7 2 15.40 871 27 3.37 / 21.32 2 54
5 7 231.7 80 15.48 537 665 4.04 / 21.99 2 46
6 13 198.1 80 15.45 502 620 4.66 / 22.61 2 48
7 14 -0.3 133 15.45 365 750 5.41 / 23.36 2 114
Average= 5.84
(KJ/cycle)

Cycle 2 GMT 30/ 7/2018 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.7 383 15.31 416 2439 2.44 / 15.07 2 33
2 6 1004.7 57 15.30 1034 902 3.34 / 15.97 2 50
3 3 805.5 10 15.35 949 146 3.49 / 16.12 2 52
4 7 135.3 80 15.49 464 575 4.06 / 16.69 2 42
5 13 102.5 80 15.46 431 533 4.59 / 17.23 2 43
6 14 0.0 131 15.45 357 723 5.32 / 17.95 2 112
Average= 5.98
(KJ/cycle)

Cycle 1 GMT 30/ 7/2018 5:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.9 307 15.32 381 1792 1.79 / 7.56 2 34
2 6 1014.0 57 15.27 1005 875 2.67 / 8.44 2 50
3 3 1259.1 33 15.26 1191 600 3.27 / 9.04 2 52
4 3 1224.7 31 15.27 1201 569 3.83 / 9.60 2 56
5 3 1037.0 22 15.31 1097 369 4.20 / 9.97 2 57
6 3 824.7 11 15.35 978 165 4.37 / 10.14 2 59
7 7 460.2 80 15.39 722 889 5.26 / 11.03 2 57
8 13 424.1 80 15.36 686 843 6.10 / 11.87 2 60
9 14 -0.1 125 15.40 396 762 6.86 / 12.63 2 110
Average= 6.32
(KJ/cycle)

Cycle 0 GMT 29/ 7/2018 20: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 163.7 460 15.55 485 3469 3.47 / 3.47 2 35
2 7 251.9 80 15.45 502 620 4.09 / 4.09 2 34
3 13 256.6 80 15.42 493 608 4.70 / 4.70 2 38
4 13 173.8 80 15.40 441 543 5.24 / 5.24 2 45
5 14 -0.1 69 15.39 348 370 5.61 / 5.61 2 109
6 14 -0.2 31 15.38 333 159 5.77 / 5.77 20 244
Average= 5.77
(KJ/cycle)