Cycle 37 GMT 25/ 6/2019 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 36 12.11 478 208 0.21 / 142.94 3 4
2 10 1027.56 3 12.22 1713 63 0.27 / 143.00 3 5
3 3 1076.04 2 12.19 1800 44 0.32 / 143.04 3 7
4 3 1030.44 1 12.25 1755 21 0.34 / 143.07 3 6
5 12 1184.60 3 11.75 1908 67 0.40 / 143.13 3 4
6 7 2003.16 33 11.01 2835 1030 1.43 / 144.16 4 5
7 13 1859.00 16 10.94 2687 470 1.90 / 144.63 3 6
8 13 1555.76 16 10.94 2325 407 2.31 / 145.04 3 7
9 13 1247.84 16 11.02 1935 341 2.65 / 145.38 3 8
10 13 941.28 16 11.14 1570 280 2.93 / 145.66 3 10
11 13 471.32 16 11.40 965 176 3.11 / 145.84 3 11
12 13 155.64 16 11.57 545 101 3.21 / 145.94 3 14
13 8 0.28 165 11.62 251 481 3.69 / 146.42 5 248
Average= 3.85
(KJ/cycle)

Cycle 36 GMT 15/ 6/2019 4:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 36 13.62 493 242 0.24 / 139.28 3 4
2 3 1023.32 1 13.75 1730 24 0.27 / 139.30 3 6
3 12 1168.72 3 12.25 1914 70 0.34 / 139.37 3 4
4 7 2005.44 33 11.67 2845 1096 1.43 / 140.47 4 5
5 13 1860.96 16 11.59 2697 500 1.93 / 140.97 3 6
6 13 1396.84 16 11.65 2136 398 2.33 / 141.37 3 8
7 13 1100.56 16 11.71 1765 331 2.66 / 141.70 3 9
8 13 787.48 16 11.81 1382 261 2.92 / 141.96 3 11
9 13 452.80 16 11.96 942 180 3.10 / 142.14 3 12
10 13 32.00 16 12.15 383 74 3.18 / 142.21 3 14
11 8 -0.04 165 12.12 256 512 3.69 / 142.73 4 248
12 14 -0.04 1 12.13 231 3 3.69 / 142.73 248 248
Average= 3.86
(KJ/cycle)

Cycle 35 GMT 5/ 6/2019 6:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 34 13.77 500 234 0.23 / 135.56 3 3
2 10 1028.00 2 13.86 1760 49 0.28 / 135.61 3 5
3 3 1041.52 1 13.88 1756 24 0.31 / 135.63 3 6
4 12 1335.00 3 13.69 2105 86 0.39 / 135.72 3 4
5 7 2005.16 33 13.31 2859 1256 1.65 / 136.97 4 6
6 13 1685.08 16 13.30 2517 536 2.19 / 137.51 3 8
7 13 1193.48 16 13.35 1904 407 2.59 / 137.92 3 11
8 13 741.20 16 13.45 1329 286 2.88 / 138.20 3 11
9 13 254.08 16 13.59 701 152 3.03 / 138.35 3 12
10 13 10.56 16 13.66 374 82 3.11 / 138.44 3 13
11 8 0.24 165 13.64 266 599 3.71 / 139.04 4 248
12 14 0.24 1 13.64 246 3 3.71 / 139.04 248 248
Average= 3.86
(KJ/cycle)

Cycle 34 GMT 26/ 5/2019 8: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 34 14.68 503 251 0.25 / 131.94 3 3
2 12 1173.00 3 13.88 1915 80 0.33 / 132.02 3 5
3 7 2003.80 33 13.47 2861 1272 1.60 / 133.29 5 5
4 13 1535.80 16 13.48 2323 501 2.10 / 133.79 3 7
5 13 1225.56 16 13.50 1948 421 2.52 / 134.21 3 10
6 13 897.80 16 13.55 1541 334 2.86 / 134.54 3 11
7 13 237.36 16 13.74 677 149 3.01 / 134.69 3 11
8 8 0.20 165 13.80 278 633 3.64 / 135.32 3 248
Average= 3.87
(KJ/cycle)

Cycle 33 GMT 16/ 5/2019 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 33 14.79 507 247 0.25 / 128.13 3 3
2 12 1180.24 3 14.73 1923 85 0.33 / 128.22 3 5
3 7 2004.56 33 14.34 2882 1364 1.70 / 129.58 5 5
4 13 1538.84 16 14.39 2343 539 2.24 / 130.12 3 8
5 13 1204.52 16 14.42 1942 448 2.68 / 130.57 3 10
6 13 689.44 16 14.55 1283 299 2.98 / 130.87 3 12
7 13 86.28 16 14.72 486 114 3.10 / 130.98 3 11
8 8 -0.16 165 14.73 289 702 3.80 / 131.68 3 248
Average= 3.87
(KJ/cycle)

Cycle 32 GMT 6/ 5/2019 11:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 33 14.84 499 244 0.24 / 124.28 3 3
2 12 1173.96 3 14.78 1963 87 0.33 / 124.37 3 5
3 7 2003.72 34 14.40 2880 1410 1.74 / 125.78 5 5
4 13 1509.76 16 14.47 2313 536 2.28 / 126.32 3 7
5 13 1165.64 16 14.51 1894 440 2.72 / 126.76 3 9
6 13 654.00 16 14.64 1245 292 3.01 / 127.05 3 11
7 13 72.44 16 14.82 470 111 3.12 / 127.16 3 10
8 8 0.20 165 14.82 297 726 3.85 / 127.89 3 248
Average= 3.88
(KJ/cycle)

Cycle 31 GMT 26/ 4/2019 13:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 33 14.90 505 248 0.25 / 120.38 3 3
2 12 1171.84 3 14.80 1914 85 0.33 / 120.46 3 4
3 7 2001.24 34 14.41 2883 1412 1.75 / 121.87 4 5
4 13 1666.92 16 14.44 2498 577 2.32 / 122.45 3 7
5 13 1147.36 16 14.54 1880 437 2.76 / 122.89 3 7
6 13 643.64 16 14.67 1232 289 3.05 / 123.18 3 10
7 13 68.48 16 14.85 465 110 3.16 / 123.29 3 9
8 8 -0.08 165 14.85 307 752 3.91 / 124.04 3 248
Average= 3.88
(KJ/cycle)

Cycle 30 GMT 16/ 4/2019 14:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 33 14.92 501 247 0.25 / 116.56 3 3
2 12 1148.96 3 14.81 1905 85 0.33 / 116.64 3 4
3 7 2005.36 33 14.44 2882 1373 1.70 / 118.02 4 5
4 13 1531.60 16 14.51 2341 543 2.25 / 118.56 3 6
5 13 1049.16 16 14.61 1745 408 2.66 / 118.97 3 7
6 13 567.08 16 14.74 1133 267 2.92 / 119.23 3 8
7 13 96.52 16 14.90 507 121 3.04 / 119.35 3 9
8 8 0.20 165 14.90 314 772 3.82 / 120.13 3 248
Average= 3.88
(KJ/cycle)

Cycle 29 GMT 6/ 4/2019 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 33 14.94 513 253 0.25 / 112.63 3 3
2 12 1156.60 3 14.85 1909 85 0.34 / 112.71 3 4
3 7 2004.04 33 14.48 2869 1371 1.71 / 114.08 4 5
4 13 1525.36 16 14.55 2332 543 2.25 / 114.62 3 6
5 13 1044.92 16 14.66 1738 408 2.66 / 115.03 3 6
6 13 711.36 16 14.73 1315 310 2.97 / 115.34 3 7
7 13 81.00 16 14.94 479 115 3.08 / 115.46 3 8
8 13 18.84 16 14.96 397 95 3.18 / 115.55 3 9
9 8 -0.12 165 14.94 308 759 3.94 / 116.31 3 248
Average= 3.88
(KJ/cycle)

Cycle 28 GMT 27/ 3/2019 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 33 14.94 495 244 0.24 / 108.74 3 3
2 12 1170.48 3 14.84 1922 86 0.33 / 108.82 3 4
3 7 2003.48 33 14.48 2884 1378 1.71 / 110.20 4 5
4 13 1530.76 16 14.55 2342 545 2.25 / 110.75 3 6
5 13 1201.36 16 14.61 1933 452 2.70 / 111.20 3 6
6 13 534.88 16 14.80 1091 258 2.96 / 111.46 3 7
7 13 55.88 16 14.96 447 107 3.07 / 111.56 3 7
8 8 0.08 165 14.95 328 809 3.88 / 112.37 3 248
Average= 3.87
(KJ/cycle)

Cycle 27 GMT 17/ 3/2019 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 33 14.92 508 250 0.25 / 104.78 3 3
2 12 1176.52 3 14.83 1934 86 0.34 / 104.86 3 4
3 7 2001.52 33 14.48 2881 1377 1.71 / 106.24 4 4
4 13 1500.24 16 14.56 2303 537 2.25 / 106.78 3 5
5 13 1165.72 16 14.62 1890 442 2.69 / 107.22 3 6
6 13 819.04 16 14.70 1461 344 3.04 / 107.56 3 7
7 13 62.56 16 14.96 449 107 3.14 / 107.67 3 6
8 8 0.04 165 14.95 334 824 3.97 / 108.49 3 248
Average= 3.87
(KJ/cycle)

Cycle 26 GMT 7/ 3/2019 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 33 14.93 498 245 0.25 / 100.92 3 3
2 12 1176.32 3 14.82 1946 87 0.33 / 101.01 3 4
3 7 2003.20 33 14.46 2883 1376 1.71 / 102.38 4 4
4 13 1495.16 16 14.56 2278 531 2.24 / 102.91 3 5
5 13 1025.52 16 14.66 1721 404 2.64 / 103.32 3 6
6 13 549.08 16 14.80 1117 265 2.91 / 103.58 3 6
7 13 48.60 16 14.95 441 105 3.01 / 103.69 3 5
8 8 0.08 165 14.94 341 841 3.85 / 104.53 3 248
Average= 3.87
(KJ/cycle)

Cycle 25 GMT 25/ 2/2019 22:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 33 14.94 496 245 0.24 / 96.99 3 3
2 12 1168.04 3 14.83 1925 86 0.33 / 97.07 3 4
3 7 2001.68 33 14.47 2876 1373 1.70 / 98.44 4 4
4 13 1502.84 16 14.56 2307 537 2.24 / 98.98 3 5
5 13 1030.84 16 14.66 1732 406 2.65 / 99.39 3 6
6 13 697.92 16 14.74 1309 309 2.96 / 99.70 3 6
7 13 74.56 16 14.94 477 114 3.07 / 99.81 3 5
8 8 0.12 165 14.93 349 860 3.93 / 100.67 3 248
9 14 0.12 1 14.94 271 4 3.93 / 100.67 248 248
Average= 3.87
(KJ/cycle)

Cycle 24 GMT 16/ 2/2019 0:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 33 14.93 508 250 0.25 / 93.11 3 3
2 12 1166.88 3 14.83 1921 85 0.34 / 93.20 3 3
3 7 2004.48 33 14.47 2881 1376 1.71 / 94.57 3 4
4 13 1368.68 16 14.60 2151 502 2.21 / 95.08 3 5
5 13 1063.36 16 14.66 1766 414 2.63 / 95.49 3 5
6 13 557.88 16 14.80 1126 267 2.89 / 95.76 3 6
7 13 48.36 16 14.96 441 106 3.00 / 95.86 3 5
8 8 0.04 165 14.94 354 873 3.87 / 96.74 3 248
9 14 0.04 1 14.94 284 4 3.88 / 96.74 248 248
Average= 3.87
(KJ/cycle)

Cycle 23 GMT 6/ 2/2019 1:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 33 14.94 511 252 0.25 / 89.16 3 3
2 12 1196.56 3 14.83 1977 88 0.34 / 89.24 3 3
3 7 2001.88 33 14.49 2884 1379 1.72 / 90.62 3 4
4 13 1504.40 16 14.59 2310 539 2.26 / 91.16 3 5
5 13 1029.36 16 14.69 1724 405 2.66 / 91.57 3 5
6 13 690.92 16 14.76 1312 310 2.97 / 91.88 3 5
7 13 41.28 16 14.97 432 103 3.08 / 91.98 3 5
8 8 0.20 165 14.95 358 883 3.96 / 92.86 3 248
Average= 3.87
(KJ/cycle)

Cycle 22 GMT 27/ 1/2019 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 33 14.94 504 248 0.25 / 85.17 3 3
2 12 1166.32 3 14.87 1930 86 0.33 / 85.26 3 3
3 7 2006.56 33 14.50 2886 1381 1.72 / 86.64 3 4
4 13 1521.92 16 14.59 2332 544 2.26 / 87.18 3 5
5 13 1180.64 16 14.65 1916 449 2.71 / 87.63 3 5
6 13 518.96 16 14.83 1075 255 2.96 / 87.89 3 5
7 13 79.48 16 14.97 487 117 3.08 / 88.00 3 5
8 8 0.20 165 14.95 365 900 3.98 / 88.90 3 248
Average= 3.87
(KJ/cycle)

Cycle 21 GMT 17/ 1/2019 5: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 33 14.94 511 252 0.25 / 81.23 3 3
2 12 1177.68 3 14.86 1946 87 0.34 / 81.32 3 3
3 7 2003.20 33 14.51 2897 1387 1.73 / 82.71 3 3
4 13 1505.80 16 14.59 2316 541 2.27 / 83.25 3 5
5 13 1028.00 16 14.71 1724 406 2.67 / 83.65 3 5
6 13 551.44 16 14.82 1117 265 2.94 / 83.92 3 5
7 13 45.28 16 14.98 441 106 3.04 / 84.02 3 5
8 8 -0.04 165 14.96 364 898 3.94 / 84.92 3 30
Average= 3.86
(KJ/cycle)

Cycle 20 GMT 7/ 1/2019 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 33 14.93 516 254 0.25 / 77.29 3 3
2 12 1172.52 3 14.85 1955 87 0.34 / 77.38 3 3
3 7 2003.60 33 14.51 2886 1382 1.72 / 78.76 3 3
4 13 1519.44 16 14.60 2332 545 2.27 / 79.30 3 5
5 13 1030.60 16 14.69 1747 411 2.68 / 79.71 3 5
6 13 540.00 16 14.83 1108 263 2.94 / 79.98 3 5
7 13 46.36 16 14.98 444 106 3.05 / 80.08 3 4
8 8 -0.08 165 14.96 364 898 3.95 / 80.98 3 20
Average= 3.86
(KJ/cycle)

Cycle 19 GMT 28/12/2018 8: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 33 14.92 510 251 0.25 / 73.28 3 3
2 12 1175.56 3 14.86 1976 88 0.34 / 73.36 3 3
3 7 2003.68 33 14.51 2899 1388 1.73 / 74.75 3 3
4 13 1509.48 17 14.59 2325 577 2.30 / 75.33 3 4
5 13 1023.72 17 14.69 1733 433 2.74 / 75.76 3 5
6 13 517.08 17 14.83 1077 272 3.01 / 76.03 3 5
7 13 33.16 17 14.98 420 107 3.12 / 76.14 3 4
8 8 0.20 165 14.94 363 895 4.01 / 77.03 3 15
Average= 3.85
(KJ/cycle)

Cycle 18 GMT 18/12/2018 9:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 33 14.92 517 255 0.25 / 69.24 3 3
2 12 1177.08 3 14.86 1956 87 0.34 / 69.33 3 3
3 7 2003.32 34 14.51 2899 1430 1.77 / 70.76 3 3
4 13 1505.36 17 14.59 2309 573 2.34 / 71.33 3 4
5 13 1016.08 17 14.69 1725 431 2.78 / 71.76 3 4
6 13 516.08 17 14.82 1074 271 3.05 / 72.03 3 4
7 13 31.36 17 14.97 414 105 3.15 / 72.14 3 4
8 8 -0.04 165 14.94 359 885 4.04 / 73.02 3 17
Average= 3.84
(KJ/cycle)

Cycle 17 GMT 8/12/2018 11:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 32 14.92 517 247 0.25 / 65.21 3 3
2 12 1179.56 3 14.86 1960 87 0.33 / 65.29 3 3
3 7 2003.40 33 14.51 2906 1391 1.73 / 66.69 3 3
4 13 1515.48 17 14.60 2328 578 2.30 / 67.26 3 4
5 13 1025.76 17 14.69 1736 434 2.74 / 67.70 3 4
6 13 523.32 17 14.82 1086 274 3.01 / 67.97 3 4
7 13 35.00 17 14.97 422 107 3.12 / 68.08 3 4
8 8 0.28 165 14.94 369 910 4.03 / 68.99 3 13
Average= 3.83
(KJ/cycle)

Cycle 16 GMT 28/11/2018 12:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 32 14.91 508 242 0.24 / 61.25 3 3
2 12 1181.20 3 14.88 1968 88 0.33 / 61.34 3 3
3 7 2002.04 34 14.52 2896 1430 1.76 / 62.77 3 3
4 13 1364.16 17 14.63 2153 535 2.30 / 63.31 3 4
5 13 919.44 17 14.73 1579 395 2.69 / 63.70 3 4
6 13 433.48 17 14.85 960 242 2.93 / 63.94 3 4
7 13 22.12 17 14.97 410 104 3.04 / 64.05 3 4
8 8 -0.04 165 14.94 370 912 3.95 / 64.96 3 10
Average= 3.82
(KJ/cycle)

Cycle 15 GMT 18/11/2018 14:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 32 14.92 517 247 0.25 / 57.26 3 3
2 12 1172.68 3 14.87 1964 88 0.33 / 57.35 3 3
3 7 2002.04 33 14.53 2890 1386 1.72 / 58.73 3 3
4 13 1496.04 17 14.60 2305 572 2.29 / 59.30 3 3
5 13 1011.92 17 14.70 1702 425 2.72 / 59.73 3 4
6 13 516.48 17 14.83 1063 268 2.99 / 60.00 3 4
7 13 33.08 17 14.97 423 108 3.09 / 60.10 3 4
8 8 -0.12 165 14.93 368 907 4.00 / 61.01 3 11
Average= 3.81
(KJ/cycle)

Cycle 14 GMT 8/11/2018 16: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 32 14.92 512 244 0.24 / 53.36 3 3
2 12 1158.96 3 14.89 1901 85 0.33 / 53.45 3 3
3 7 2002.36 33 14.54 2895 1389 1.72 / 54.84 3 3
4 13 1489.40 17 14.60 2317 575 2.29 / 55.41 3 4
5 13 1005.36 17 14.71 1699 425 2.72 / 55.84 3 4
6 13 506.08 17 14.83 1065 268 2.99 / 56.10 3 4
7 8 0.28 165 14.94 368 907 3.89 / 57.01 3 9
Average= 3.80
(KJ/cycle)

Cycle 13 GMT 29/10/2018 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 32 14.92 527 252 0.25 / 49.43 3 3
2 12 1169.24 3 14.91 1948 87 0.34 / 49.52 3 3
3 7 2005.28 33 14.54 2908 1395 1.73 / 50.91 3 3
4 13 1510.56 17 14.60 2341 581 2.32 / 51.49 3 3
5 13 1019.60 17 14.71 1726 432 2.75 / 51.93 3 4
6 13 510.48 17 14.83 1068 269 3.02 / 52.20 3 4
7 8 -0.24 165 14.94 374 922 3.94 / 53.12 3 9
Average= 3.79
(KJ/cycle)

Cycle 12 GMT 19/10/2018 19: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 32 14.92 524 250 0.25 / 45.55 3 3
2 12 1162.12 3 14.90 1952 87 0.34 / 45.63 3 3
3 7 2003.12 33 14.54 2908 1395 1.73 / 47.03 3 3
4 13 1503.92 17 14.61 2335 580 2.31 / 47.61 3 3
5 13 1013.56 17 14.71 1727 432 2.74 / 48.04 3 3
6 13 375.52 17 14.88 892 226 2.97 / 48.27 3 4
7 8 0.28 165 14.95 370 913 3.88 / 49.18 3 10
Average= 3.78
(KJ/cycle)

Cycle 11 GMT 9/10/2018 20:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 32 14.90 534 255 0.25 / 41.58 3 3
2 12 1176.84 3 14.90 1971 88 0.34 / 41.67 3 3
3 7 2003.08 34 14.54 2911 1439 1.78 / 43.11 3 3
4 13 1488.24 17 14.62 2300 572 2.35 / 43.68 3 3
5 13 991.68 17 14.72 1697 425 2.78 / 44.11 3 3
6 13 473.36 17 14.85 1024 259 3.04 / 44.37 3 3
7 8 0.12 165 14.95 377 930 3.97 / 45.30 3 10
Average= 3.77
(KJ/cycle)

Cycle 10 GMT 29/ 9/2018 21:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 32 14.91 522 249 0.25 / 37.56 3 3
2 12 1161.04 3 14.91 1966 88 0.34 / 37.64 3 3
3 7 2001.88 36 14.52 2909 1521 1.86 / 39.16 3 3
4 13 1475.44 17 14.63 2277 566 2.42 / 39.73 3 3
5 13 961.28 17 14.73 1652 414 2.84 / 40.14 3 3
6 13 444.32 17 14.85 987 249 3.09 / 40.39 3 4
7 8 0.32 165 14.94 380 937 4.02 / 41.33 3 9
Average= 3.76
(KJ/cycle)

Cycle 9 GMT 19/ 9/2018 22:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 32 14.92 529 253 0.25 / 33.59 3 3
2 3 1015.80 1 15.00 1784 27 0.28 / 33.61 3 3
3 12 1174.40 3 14.92 1985 89 0.37 / 33.70 3 3
4 7 2001.28 36 14.54 2900 1518 1.89 / 35.22 3 3
5 13 1329.12 17 14.66 2121 529 2.41 / 35.75 3 3
6 13 997.52 17 14.72 1709 428 2.84 / 36.18 3 3
7 13 297.64 17 14.90 794 201 3.04 / 36.38 3 3
8 8 0.16 165 14.94 377 929 3.97 / 37.31 3 9
Average= 3.73
(KJ/cycle)

Cycle 8 GMT 10/ 9/2018 0:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 14.93 521 241 0.24 / 29.64 3 3
2 3 1015.52 1 15.02 1750 26 0.27 / 29.66 3 3
3 7 2010.92 36 14.57 2900 1521 1.79 / 31.19 3 3
4 13 1491.00 17 14.65 2320 578 2.37 / 31.76 3 3
5 13 989.16 17 14.75 1696 425 2.79 / 32.19 3 3
6 13 357.68 17 14.90 874 221 3.01 / 32.41 3 3
7 8 0.12 165 14.96 374 923 3.94 / 33.33 3 7
Average= 3.70
(KJ/cycle)

Cycle 7 GMT 31/ 8/2018 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 31 14.95 523 242 0.24 / 25.42 3 3
2 3 1018.40 1 15.03 1767 27 0.27 / 25.44 3 3
3 7 2004.88 41 14.57 2894 1729 2.00 / 27.17 3 3
4 13 1464.00 21 14.66 2274 700 2.70 / 27.87 3 3
5 13 759.92 21 14.82 1386 431 3.13 / 28.30 3 3
6 13 94.52 21 14.99 517 163 3.29 / 28.47 3 4
7 8 0.12 165 14.97 377 931 4.22 / 29.40 3 7
Average= 3.67
(KJ/cycle)

Cycle 6 GMT 21/ 8/2018 4:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 30 14.99 522 235 0.23 / 21.22 3 3
2 10 1003.52 2 15.00 1745 52 0.29 / 21.27 3 3
3 7 2005.52 41 14.60 2891 1731 2.02 / 23.00 3 3
4 13 1338.44 21 14.72 2080 643 2.66 / 23.64 3 3
5 13 815.36 21 14.81 1456 453 3.11 / 24.09 3 3
6 13 58.88 21 15.01 464 146 3.26 / 24.24 3 3
7 8 -0.24 165 14.98 378 934 4.19 / 25.17 3 9
Average= 3.60
(KJ/cycle)

Cycle 5 GMT 11/ 8/2018 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 29 15.04 507 221 0.22 / 17.24 3 3
2 10 1012.16 2 15.03 1727 52 0.27 / 17.29 3 3
3 7 2009.48 36 14.66 2864 1512 1.78 / 18.80 3 3
4 13 1484.20 18 14.73 2273 603 2.39 / 19.40 3 3
5 13 973.52 18 14.83 1646 439 2.83 / 19.84 3 3
6 13 296.56 18 15.00 782 211 3.04 / 20.06 3 3
7 8 0.04 165 15.03 373 925 3.96 / 20.98 3 6
Average= 3.50
(KJ/cycle)

Cycle 4 GMT 1/ 8/2018 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 30 15.03 513 231 0.23 / 13.79 3 3
2 7 1507.52 36 14.84 2282 1219 1.45 / 15.01 3 3
3 13 1368.40 18 14.84 2110 564 2.01 / 15.57 3 3
4 13 851.12 18 14.93 1461 393 2.41 / 15.96 3 3
5 13 156.96 18 15.09 567 154 2.56 / 16.12 3 3
6 8 0.12 165 15.08 362 901 3.46 / 17.02 3 5
Average= 3.40
(KJ/cycle)

Cycle 3 GMT 31/ 7/2018 10:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 29 15.04 502 219 0.22 / 9.60 3 3
2 3 1043.48 1 15.06 1786 27 0.25 / 9.63 3 3
3 7 1523.32 74 14.75 2284 2493 2.74 / 12.12 3 3
4 13 168.16 18 15.08 601 163 2.90 / 12.28 3 3
5 8 0.12 240 15.07 352 1273 4.18 / 13.56 3 11
Average= 3.39
(KJ/cycle)

Cycle 2 GMT 30/ 7/2018 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 24 15.11 485 176 0.18 / 5.23 3 3
2 10 1052.80 3 15.07 1773 80 0.26 / 5.31 3 3
3 3 1089.44 2 15.07 1839 55 0.31 / 5.37 3 3
4 3 1021.56 1 15.12 1771 27 0.34 / 5.39 3 3
5 7 1506.80 75 14.77 2242 2484 2.82 / 7.88 3 3
6 13 270.52 18 15.07 732 199 3.02 / 8.08 3 3
7 8 0.08 240 15.07 361 1306 4.33 / 9.38 3 11
Average= 3.13
(KJ/cycle)

Cycle 1 GMT 29/ 7/2018 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 23 15.26 444 156 0.16 / 1.84 3 3
2 10 1064.36 3 15.13 1781 81 0.24 / 1.92 3 3
3 10 1098.32 2 15.12 1840 56 0.29 / 1.98 3 3
4 3 1078.96 2 15.12 1825 55 0.35 / 2.03 3 3
5 3 1020.20 1 15.16 1741 26 0.37 / 2.06 3 3
6 7 1006.16 74 14.98 1615 1790 2.16 / 3.85 3 3
7 8 0.04 240 15.15 332 1207 3.37 / 5.05 3 16
Average= 2.53
(KJ/cycle)

Cycle 0 GMT 29/ 7/2018 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.12 22 15.39 395 134 0.13 / 0.13 3 3
2 7 74.68 74 15.35 407 462 0.60 / 0.60 3 3
3 8 0.16 240 15.31 296 1088 1.68 / 1.68 3 8
Average= 1.68
(KJ/cycle)