SIO Argo Site:
Pump Diagnostics Page   



Serial= 8588 WMO= 3901477

Return

←PreviousNext→

Cycle 263 GMT 16/12/2024 1:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 23 14.87 473 162 0.16 / 1140.77 2 2
2 7 2003.12 42 14.11 3016 1787 1.95 / 1142.56 2 2
3 13 1733.56 20 14.19 2690 763 2.71 / 1143.32 2 2
4 13 1144.44 20 14.37 1919 552 3.26 / 1143.87 2 2
5 13 427.76 20 14.70 943 277 3.54 / 1144.15 2 2
6 13 29.64 20 14.92 371 111 3.65 / 1144.26 2 2
7 8 0.12 175 14.89 316 823 4.48 / 1145.08 2 6
Average= 4.34
(KJ/cycle)

Cycle 262 GMT 6/12/2024 1:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 23 14.85 480 164 0.16 / 1136.50 2 2
2 3 969.32 -1 15.37 0 0 0.00 / 1136.50 2 2
3 7 2006.76 43 14.10 3014 1827 1.99 / 1138.33 2 2
4 13 1602.68 20 14.23 2519 717 2.71 / 1139.04 2 2
5 13 1041.88 20 14.42 1767 510 3.22 / 1139.55 2 2
6 13 330.44 20 14.76 795 235 3.45 / 1139.79 2 2
7 8 0.12 175 14.91 315 822 4.27 / 1140.61 2 4
Average= 4.34
(KJ/cycle)

Cycle 261 GMT 26/11/2024 1:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 23 14.86 485 166 0.17 / 1132.03 2 2
2 7 2006.20 42 14.11 3020 1790 1.96 / 1133.81 2 2
3 13 1741.08 20 14.19 2703 767 2.72 / 1134.58 2 2
4 13 1043.28 20 14.42 1780 513 3.24 / 1135.10 2 2
5 13 473.88 20 14.68 1011 297 3.53 / 1135.39 2 2
6 13 43.12 20 14.91 392 117 3.65 / 1135.51 2 2
7 8 0.08 175 14.89 317 826 4.48 / 1136.34 2 4
Average= 4.34
(KJ/cycle)

Cycle 260 GMT 16/11/2024 1:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 23 14.86 478 163 0.16 / 1127.70 2 2
2 7 2005.12 42 14.11 3029 1795 1.96 / 1129.50 2 2
3 13 1613.60 20 14.22 2533 720 2.68 / 1130.22 2 2
4 13 1045.72 20 14.41 1788 515 3.19 / 1130.74 2 2
5 13 463.76 20 14.68 996 292 3.49 / 1131.03 2 2
6 8 0.28 175 14.90 319 832 4.32 / 1131.86 2 3
Average= 4.34
(KJ/cycle)

Cycle 259 GMT 6/11/2024 1: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 23 14.85 485 166 0.17 / 1123.42 2 2
2 7 2003.64 42 14.10 3010 1783 1.95 / 1125.20 2 2
3 13 1596.88 20 14.23 2490 709 2.66 / 1125.91 2 2
4 13 1042.48 20 14.41 1779 513 3.17 / 1126.42 2 2
5 13 471.16 20 14.68 1002 294 3.46 / 1126.71 2 2
6 8 0.08 175 14.90 317 827 4.29 / 1127.54 2 2
Average= 4.34
(KJ/cycle)

Cycle 258 GMT 27/10/2024 0:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 23 14.86 480 164 0.16 / 1118.99 2 2
2 7 2003.72 42 14.11 3023 1791 1.96 / 1120.78 2 2
3 13 1599.32 20 14.23 2529 720 2.68 / 1121.50 2 2
4 13 1037.80 20 14.42 1773 511 3.19 / 1122.01 2 2
5 13 476.52 20 14.68 1014 298 3.48 / 1122.31 2 2
6 13 16.72 20 14.93 352 105 3.59 / 1122.41 2 2
7 8 0.36 175 14.89 321 836 4.43 / 1123.25 2 2
Average= 4.34
(KJ/cycle)

Cycle 257 GMT 17/10/2024 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 23 14.85 485 166 0.17 / 1114.54 2 2
2 7 2006.04 42 14.11 3020 1790 1.96 / 1116.33 2 2
3 13 1733.40 20 14.20 2682 762 2.72 / 1117.09 2 2
4 13 1025.32 20 14.44 1745 504 3.22 / 1117.59 2 2
5 13 455.76 20 14.69 982 289 3.51 / 1117.88 2 2
6 13 33.56 20 14.93 377 113 3.62 / 1118.00 2 2
7 8 -0.08 175 14.90 318 829 4.45 / 1118.82 2 5
Average= 4.34
(KJ/cycle)

Cycle 256 GMT 7/10/2024 0:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 23 14.87 481 165 0.16 / 1110.08 2 2
2 7 2006.24 42 14.11 3007 1782 1.95 / 1111.87 2 2
3 13 1601.84 20 14.24 2513 716 2.66 / 1112.58 2 2
4 13 1171.68 20 14.37 1945 559 3.22 / 1113.14 2 2
5 13 452.56 20 14.70 973 286 3.51 / 1113.43 2 2
6 13 31.44 20 14.93 374 112 3.62 / 1113.54 2 2
7 8 0.28 175 14.90 320 834 4.45 / 1114.37 2 3
Average= 4.34
(KJ/cycle)

Cycle 255 GMT 27/ 9/2024 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 23 14.86 468 160 0.16 / 1105.73 2 2
2 7 2005.48 42 14.12 3014 1787 1.95 / 1107.52 2 2
3 13 1729.88 20 14.20 2685 763 2.71 / 1108.28 2 2
4 13 1028.16 20 14.43 1756 507 3.22 / 1108.79 2 2
5 13 463.84 20 14.69 998 293 3.51 / 1109.08 2 2
6 8 0.08 175 14.91 322 840 4.35 / 1109.92 2 3
Average= 4.34
(KJ/cycle)

Cycle 254 GMT 16/ 9/2024 23:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 23 14.86 475 162 0.16 / 1101.18 2 2
2 7 2009.36 42 14.11 3035 1799 1.96 / 1102.98 2 2
3 13 1742.48 20 14.19 2711 769 2.73 / 1103.75 2 2
4 13 1147.68 20 14.38 1910 549 3.28 / 1104.30 2 2
5 13 558.52 20 14.64 1127 330 3.61 / 1104.63 2 2
6 13 25.04 20 14.93 365 109 3.72 / 1104.74 2 2
7 8 -0.04 175 14.90 320 834 4.55 / 1105.57 2 4
Average= 4.34
(KJ/cycle)

Cycle 253 GMT 6/ 9/2024 23:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 23 14.86 477 163 0.16 / 1096.71 2 2
2 7 2004.84 42 14.11 3021 1790 1.95 / 1098.50 2 2
3 13 1603.64 20 14.23 2514 715 2.67 / 1099.21 2 2
4 13 1175.04 20 14.37 1954 562 3.23 / 1099.78 2 2
5 13 463.88 20 14.69 1005 295 3.53 / 1100.07 2 2
6 13 16.96 20 14.94 357 107 3.63 / 1100.18 2 2
7 8 0.08 175 14.90 322 840 4.47 / 1101.02 2 4
Average= 4.33
(KJ/cycle)

Cycle 252 GMT 27/ 8/2024 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 23 14.86 478 163 0.16 / 1092.39 2 2
2 7 2002.36 42 14.11 3017 1788 1.95 / 1094.18 2 2
3 13 1600.08 20 14.23 2531 720 2.67 / 1094.90 2 2
4 13 1032.00 20 14.43 1767 510 3.18 / 1095.41 2 2
5 13 461.84 20 14.69 998 293 3.47 / 1095.70 2 2
6 8 0.12 175 14.91 324 845 4.32 / 1096.55 2 6
Average= 4.33
(KJ/cycle)

Cycle 251 GMT 17/ 8/2024 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 23 14.86 485 166 0.17 / 1088.07 2 2
2 7 2006.12 42 14.11 3008 1783 1.95 / 1089.85 2 2
3 13 1608.24 20 14.23 2527 719 2.67 / 1090.57 2 2
4 13 1053.00 20 14.42 1792 517 3.18 / 1091.08 2 2
5 13 482.52 20 14.68 1028 302 3.49 / 1091.39 2 2
6 8 0.32 175 14.90 322 840 4.33 / 1092.23 2 2
Average= 4.33
(KJ/cycle)

Cycle 250 GMT 7/ 8/2024 23: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 23 14.85 478 163 0.16 / 1083.76 2 2
2 7 2004.32 42 14.11 3016 1787 1.95 / 1085.54 2 2
3 13 1596.60 20 14.23 2497 711 2.66 / 1086.25 2 2
4 13 1026.96 20 14.43 1757 507 3.17 / 1086.76 2 2
5 13 461.84 20 14.69 1006 296 3.46 / 1087.06 2 2
6 8 0.04 175 14.90 323 842 4.31 / 1087.90 2 3
Average= 4.33
(KJ/cycle)

Cycle 249 GMT 28/ 7/2024 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 23 14.86 482 165 0.16 / 1079.33 2 2
2 7 2005.72 42 14.11 3024 1792 1.96 / 1081.12 2 2
3 13 1597.44 20 14.24 2510 715 2.67 / 1081.83 2 2
4 13 1036.32 20 14.43 1774 512 3.18 / 1082.34 2 2
5 13 466.76 20 14.70 1008 296 3.48 / 1082.64 2 2
6 13 16.84 20 14.94 359 107 3.59 / 1082.75 2 2
7 8 -0.04 175 14.90 324 845 4.43 / 1083.59 2 3
Average= 4.33
(KJ/cycle)

Cycle 248 GMT 18/ 7/2024 22:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 23 14.86 489 167 0.17 / 1074.95 2 2
2 7 2005.48 42 14.11 3018 1789 1.96 / 1076.74 2 2
3 13 1735.04 20 14.19 2703 767 2.72 / 1077.51 2 2
4 13 1024.00 20 14.44 1765 510 3.23 / 1078.02 2 2
5 13 462.40 20 14.69 1005 295 3.53 / 1078.31 2 2
6 8 0.20 175 14.91 325 848 4.38 / 1079.16 2 5
Average= 4.33
(KJ/cycle)

Cycle 247 GMT 8/ 7/2024 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 23 14.87 493 169 0.17 / 1070.62 2 2
2 7 2004.00 42 14.11 3015 1787 1.96 / 1072.41 2 2
3 13 1591.96 20 14.23 2517 716 2.67 / 1073.12 2 2
4 13 1029.08 20 14.43 1764 509 3.18 / 1073.63 2 2
5 13 463.48 20 14.69 1002 294 3.48 / 1073.93 2 2
6 8 0.40 175 14.90 329 858 4.33 / 1074.79 2 3
Average= 4.33
(KJ/cycle)

Cycle 246 GMT 28/ 6/2024 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 23 14.87 495 169 0.17 / 1066.30 2 2
2 7 2008.76 43 14.10 3020 1831 2.00 / 1068.13 2 2
3 13 1617.68 20 14.22 2539 722 2.72 / 1068.85 2 2
4 13 1045.32 20 14.42 1785 515 3.24 / 1069.36 2 2
5 13 338.68 20 14.76 823 243 3.48 / 1069.61 2 2
6 8 0.12 175 14.91 324 845 4.33 / 1070.45 2 2
Average= 4.33
(KJ/cycle)

Cycle 245 GMT 18/ 6/2024 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 23 14.86 491 168 0.17 / 1061.85 2 2
2 7 2006.36 42 14.11 3015 1787 1.95 / 1063.64 2 2
3 13 1603.00 20 14.22 2528 719 2.67 / 1064.36 2 2
4 13 1182.64 20 14.36 1965 564 3.24 / 1064.92 2 2
5 13 591.44 20 14.63 1183 346 3.58 / 1065.27 2 2
6 8 0.32 175 14.91 328 856 4.44 / 1066.13 2 2
Average= 4.33
(KJ/cycle)

Cycle 244 GMT 8/ 6/2024 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 24 14.87 476 170 0.17 / 1057.02 2 2
2 3 968.76 -1 15.35 0 0 0.00 / 1057.02 2 2
3 3 1023.04 1 15.01 1857 28 0.20 / 1057.05 2 2
4 7 2005.28 42 14.10 3022 1790 1.99 / 1058.84 2 2
5 13 1735.20 20 14.19 2681 761 2.75 / 1059.60 2 2
6 13 1033.28 20 14.43 1771 511 3.26 / 1060.11 2 2
7 13 597.04 20 14.62 1196 350 3.61 / 1060.46 2 2
8 13 315.32 20 14.76 799 236 3.84 / 1060.69 2 2
9 13 85.12 20 14.88 467 139 3.98 / 1060.83 2 2
10 8 -0.04 175 14.88 328 854 4.84 / 1061.69 2 5
Average= 4.33
(KJ/cycle)

Cycle 243 GMT 29/ 5/2024 21:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 23 14.86 476 163 0.16 / 1052.74 2 2
2 7 2002.96 42 14.11 3021 1790 1.95 / 1054.53 2 2
3 13 1605.44 20 14.23 2522 718 2.67 / 1055.25 2 2
4 13 1052.60 20 14.42 1788 516 3.19 / 1055.77 2 2
5 13 353.52 20 14.76 843 249 3.44 / 1056.02 2 2
6 8 0.00 175 14.91 319 832 4.27 / 1056.85 2 4
Average= 4.33
(KJ/cycle)

Cycle 242 GMT 19/ 5/2024 20:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 23 14.87 475 162 0.16 / 1048.28 2 2
2 7 2006.36 42 14.11 3012 1785 1.95 / 1050.06 2 2
3 13 1733.60 20 14.19 2696 765 2.71 / 1050.83 2 2
4 13 1028.40 20 14.43 1761 508 3.22 / 1051.33 2 2
5 13 472.20 20 14.69 1013 298 3.52 / 1051.63 2 2
6 13 44.80 20 14.92 393 117 3.64 / 1051.75 2 2
7 8 0.00 175 14.90 319 832 4.47 / 1052.58 2 3
Average= 4.33
(KJ/cycle)

Cycle 241 GMT 9/ 5/2024 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 23 14.87 475 162 0.16 / 1043.72 2 2
2 7 2003.56 42 14.11 3016 1787 1.95 / 1045.51 2 2
3 13 1721.12 20 14.20 2668 758 2.71 / 1046.26 2 2
4 13 1269.44 20 14.33 2081 596 3.30 / 1046.86 2 2
5 13 523.16 20 14.67 1079 317 3.62 / 1047.18 2 2
6 13 23.36 20 14.94 359 107 3.73 / 1047.28 2 2
7 8 0.16 175 14.90 318 829 4.56 / 1048.11 2 5
Average= 4.33
(KJ/cycle)

Cycle 240 GMT 29/ 4/2024 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 23 14.86 464 159 0.16 / 1039.18 2 2
2 7 2006.24 42 14.11 3006 1781 1.94 / 1040.96 2 2
3 13 1737.36 20 14.19 2691 764 2.70 / 1041.73 2 2
4 13 1158.24 20 14.37 1924 553 3.26 / 1042.28 2 2
5 13 560.76 20 14.64 1128 330 3.59 / 1042.61 2 2
6 13 56.84 20 14.91 410 122 3.71 / 1042.73 2 2
7 8 0.28 175 14.90 316 824 4.53 / 1043.56 2 3
Average= 4.33
(KJ/cycle)

Cycle 239 GMT 19/ 4/2024 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 23 14.86 469 160 0.16 / 1034.77 2 2
2 7 2001.92 42 14.11 3019 1789 1.95 / 1036.56 2 2
3 13 1601.88 20 14.23 2515 716 2.67 / 1037.27 2 2
4 13 1039.52 20 14.42 1772 511 3.18 / 1037.79 2 2
5 13 466.68 20 14.68 1007 296 3.47 / 1038.08 2 2
6 13 36.00 20 14.91 383 114 3.59 / 1038.19 2 2
7 8 -0.08 175 14.89 318 829 4.41 / 1039.02 2 4
Average= 4.33
(KJ/cycle)

Cycle 238 GMT 9/ 4/2024 20:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 24 14.85 472 168 0.17 / 1030.34 2 2
2 3 968.52 -1 15.34 0 0 0.00 / 1030.34 2 2
3 3 1025.44 1 15.01 1872 28 0.20 / 1030.37 2 2
4 7 2006.20 42 14.11 3014 1786 1.98 / 1032.15 2 2
5 13 1599.60 20 14.21 2526 718 2.70 / 1032.87 2 2
6 13 1035.32 20 14.42 1769 510 3.21 / 1033.38 2 2
7 13 459.72 20 14.68 995 292 3.50 / 1033.67 2 2
8 13 33.32 20 14.91 375 112 3.61 / 1033.79 2 2
9 8 0.20 175 14.89 316 823 4.44 / 1034.61 2 3
Average= 4.33
(KJ/cycle)

Cycle 237 GMT 30/ 3/2024 20:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 24 14.87 469 167 0.17 / 1025.92 2 2
2 7 2007.24 42 14.11 3011 1784 1.95 / 1027.70 2 2
3 13 1611.68 20 14.22 2515 715 2.67 / 1028.42 2 2
4 13 1048.48 20 14.42 1780 513 3.18 / 1028.93 2 2
5 13 486.52 20 14.67 1026 301 3.48 / 1029.23 2 2
6 13 41.48 20 14.91 389 116 3.60 / 1029.35 2 2
7 8 0.28 175 14.89 316 823 4.42 / 1030.17 2 3
Average= 4.33
(KJ/cycle)

Cycle 236 GMT 20/ 3/2024 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 24 14.86 459 164 0.16 / 1021.33 2 2
2 7 2007.56 42 14.11 3014 1786 1.95 / 1023.12 2 2
3 13 1602.28 20 14.22 2510 714 2.66 / 1023.83 2 2
4 13 1178.16 20 14.36 1946 559 3.22 / 1024.39 2 2
5 13 451.72 20 14.69 977 287 3.51 / 1024.68 2 2
6 13 36.44 20 14.91 379 113 3.62 / 1024.79 2 2
7 8 0.12 175 14.89 315 821 4.44 / 1025.61 2 4
8 14 0.12 30 14.87 314 140 4.58 / 1025.75 2 3
Average= 4.33
(KJ/cycle)

Cycle 235 GMT 10/ 3/2024 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 24 14.87 457 163 0.16 / 1016.89 2 2
2 7 2007.12 42 14.11 3008 1783 1.95 / 1018.67 2 2
3 13 1739.40 20 14.18 2699 765 2.71 / 1019.43 2 2
4 13 1036.40 20 14.42 1757 507 3.22 / 1019.94 2 2
5 13 465.32 20 14.68 995 292 3.51 / 1020.23 2 2
6 13 37.04 20 14.90 383 114 3.62 / 1020.35 2 2
7 8 0.16 175 14.88 315 820 4.44 / 1021.17 2 3
Average= 4.33
(KJ/cycle)

Cycle 234 GMT 29/ 2/2024 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 23 14.86 461 158 0.16 / 1012.54 2 2
2 7 2002.96 42 14.12 3011 1786 1.94 / 1014.33 2 2
3 13 1598.92 20 14.22 2506 713 2.66 / 1015.04 2 2
4 13 1036.24 20 14.42 1746 504 3.16 / 1015.55 2 2
5 13 341.52 20 14.74 829 244 3.40 / 1015.79 2 2
6 13 23.80 20 14.91 366 109 3.51 / 1015.90 2 2
7 8 0.12 175 14.89 316 823 4.34 / 1016.72 2 6
Average= 4.33
(KJ/cycle)

Cycle 233 GMT 19/ 2/2024 19:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 23 14.85 462 158 0.16 / 1008.10 2 2
2 7 2003.56 42 14.11 3001 1778 1.94 / 1009.88 2 2
3 13 1730.48 20 14.19 2678 760 2.70 / 1010.64 2 2
4 13 1144.12 20 14.37 1897 545 3.24 / 1011.19 2 2
5 13 431.08 20 14.70 938 276 3.52 / 1011.46 2 2
6 13 33.80 20 14.91 370 110 3.63 / 1011.57 2 2
7 8 0.12 175 14.89 312 813 4.44 / 1012.39 2 4
Average= 4.33
(KJ/cycle)

Cycle 232 GMT 9/ 2/2024 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 23 14.85 473 162 0.16 / 1003.64 2 2
2 7 2008.48 43 14.10 3008 1824 1.99 / 1005.46 2 2
3 13 1613.72 20 14.21 2547 724 2.71 / 1006.19 2 2
4 13 1172.60 20 14.35 1950 560 3.27 / 1006.75 2 2
5 13 429.32 20 14.69 950 279 3.55 / 1007.02 2 2
6 13 28.92 20 14.90 363 108 3.66 / 1007.13 2 2
7 8 0.20 175 14.88 312 812 4.47 / 1007.95 2 3
Average= 4.33
(KJ/cycle)

Cycle 231 GMT 30/ 1/2024 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 24 14.85 472 168 0.17 / 999.20 2 2
2 3 967.68 -1 15.33 0 0 0.00 / 999.20 2 2
3 3 1018.04 1 15.01 1880 28 0.20 / 999.23 2 2
4 7 2007.36 42 14.10 3015 1785 1.98 / 1001.02 2 2
5 13 1605.40 20 14.21 2528 718 2.70 / 1001.73 2 2
6 13 1044.52 20 14.41 1781 513 3.21 / 1002.25 2 2
7 13 465.68 20 14.67 1007 295 3.51 / 1002.54 2 2
8 13 18.60 20 14.91 354 106 3.61 / 1002.65 2 2
9 8 -0.08 175 14.88 318 828 4.44 / 1003.48 2 3
Average= 4.33
(KJ/cycle)

Cycle 230 GMT 20/ 1/2024 19:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 24 14.85 465 166 0.17 / 994.76 2 2
2 7 2002.32 42 14.12 3008 1784 1.95 / 996.54 2 2
3 13 1736.36 20 14.19 2691 764 2.71 / 997.31 2 2
4 13 1036.60 20 14.41 1762 508 3.22 / 997.81 2 2
5 13 476.52 20 14.67 1011 297 3.52 / 998.11 2 2
6 13 18.52 20 14.91 356 106 3.62 / 998.22 2 2
7 8 0.16 175 14.88 314 818 4.44 / 999.03 2 5
Average= 4.32
(KJ/cycle)

Cycle 229 GMT 10/ 1/2024 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 24 14.85 480 171 0.17 / 990.28 2 2
2 7 2003.08 42 14.11 3017 1788 1.96 / 992.07 2 2
3 13 1734.08 20 14.18 2688 762 2.72 / 992.83 2 2
4 13 1151.80 20 14.36 1908 548 3.27 / 993.38 2 2
5 13 420.92 20 14.69 937 275 3.54 / 993.66 2 2
6 13 26.56 20 14.90 368 110 3.65 / 993.77 2 2
7 8 0.36 175 14.87 317 825 4.48 / 994.59 2 5
Average= 4.32
(KJ/cycle)

Cycle 228 GMT 31/12/2023 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 24 14.84 491 175 0.17 / 985.99 2 2
2 7 2001.72 42 14.11 3017 1788 1.96 / 987.78 2 2
3 13 1585.60 20 14.22 2498 710 2.67 / 988.49 2 2
4 13 1029.24 20 14.41 1761 508 3.18 / 989.00 2 2
5 13 452.96 20 14.67 984 289 3.47 / 989.29 2 2
6 8 0.12 175 14.88 318 828 4.30 / 990.11 2 3
Average= 4.32
(KJ/cycle)

Cycle 227 GMT 21/12/2023 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 24 14.84 471 168 0.17 / 981.59 2 2
2 7 2002.32 42 14.11 3018 1789 1.96 / 983.38 2 2
3 13 1739.00 20 14.18 2697 765 2.72 / 984.14 2 2
4 13 1150.36 20 14.36 1910 549 3.27 / 984.69 2 2
5 13 435.52 20 14.68 963 283 3.55 / 984.97 2 2
6 8 0.20 175 14.88 323 841 4.39 / 985.82 2 3
Average= 4.32
(KJ/cycle)

Cycle 226 GMT 11/12/2023 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 24 14.84 480 171 0.17 / 977.28 2 2
2 7 2004.56 42 14.11 3011 1784 1.96 / 979.07 2 2
3 13 1606.80 20 14.21 2519 716 2.67 / 979.78 2 2
4 13 1045.32 20 14.40 1783 514 3.18 / 980.30 2 2
5 13 473.44 20 14.66 1011 296 3.48 / 980.59 2 2
6 8 0.08 175 14.88 318 828 4.31 / 981.42 2 2
Average= 4.32
(KJ/cycle)

Cycle 225 GMT 1/12/2023 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 24 14.83 486 173 0.17 / 973.04 2 2
2 7 2002.88 42 14.11 3003 1780 1.95 / 974.82 2 2
3 13 1596.76 20 14.22 2501 711 2.66 / 975.53 2 2
4 13 1041.80 20 14.40 1775 511 3.18 / 976.04 2 2
5 13 340.76 20 14.73 828 244 3.42 / 976.28 2 2
6 8 0.20 175 14.88 319 831 4.25 / 977.11 2 2
Average= 4.32
(KJ/cycle)

Cycle 224 GMT 21/11/2023 19:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 23 14.84 485 166 0.17 / 968.69 2 2
2 7 2002.92 43 14.11 3012 1827 1.99 / 970.52 2 2
3 13 1591.24 20 14.21 2526 718 2.71 / 971.24 2 2
4 13 1026.96 20 14.42 1740 502 3.21 / 971.74 2 2
5 13 452.48 20 14.67 985 289 3.50 / 972.03 2 2
6 8 0.08 175 14.87 321 835 4.34 / 972.86 2 3
Average= 4.32
(KJ/cycle)

Cycle 223 GMT 11/11/2023 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 23 14.83 474 162 0.16 / 964.45 2 2
2 7 2008.36 42 14.12 3016 1789 1.95 / 966.24 2 2
3 13 1601.64 20 14.22 2518 716 2.67 / 966.95 2 2
4 13 1039.60 20 14.40 1773 511 3.18 / 967.46 2 2
5 13 346.36 20 14.73 828 244 3.42 / 967.71 2 2
6 8 0.08 175 14.88 315 820 4.24 / 968.53 2 3
Average= 4.32
(KJ/cycle)

Cycle 222 GMT 1/11/2023 19: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 24 14.82 480 171 0.17 / 960.09 2 2
2 7 2001.32 42 14.12 3003 1781 1.95 / 961.87 2 2
3 13 1727.16 20 14.18 2679 760 2.71 / 962.63 2 2
4 13 1146.44 20 14.36 1921 552 3.26 / 963.18 2 2
5 13 419.68 20 14.69 935 275 3.54 / 963.46 2 2
6 8 0.04 175 14.88 318 828 4.37 / 964.28 2 2
Average= 4.32
(KJ/cycle)

Cycle 221 GMT 22/10/2023 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 24 14.83 468 167 0.17 / 955.76 2 2
2 7 2004.64 43 14.11 3021 1833 2.00 / 957.59 2 2
3 13 1586.48 20 14.22 2498 710 2.71 / 958.31 2 2
4 13 1026.64 20 14.41 1748 504 3.21 / 958.81 2 2
5 13 449.36 20 14.67 972 285 3.50 / 959.09 2 2
6 8 0.04 175 14.87 317 825 4.32 / 959.92 2 3
Average= 4.32
(KJ/cycle)

Cycle 220 GMT 12/10/2023 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 24 14.82 482 171 0.17 / 951.48 2 2
2 7 2007.16 43 14.11 3019 1832 2.00 / 953.31 2 2
3 13 1592.80 20 14.22 2492 709 2.71 / 954.02 2 2
4 13 1033.12 20 14.40 1757 506 3.22 / 954.53 2 2
5 13 329.00 20 14.73 808 238 3.46 / 954.77 2 2
6 8 0.36 175 14.87 319 830 4.29 / 955.60 2 2
Average= 4.32
(KJ/cycle)

Cycle 219 GMT 2/10/2023 18:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 24 14.82 485 173 0.17 / 947.19 2 2
2 7 2002.72 43 14.11 3019 1832 2.00 / 949.02 2 2
3 13 1593.60 20 14.22 2514 715 2.72 / 949.73 2 2
4 13 1030.64 20 14.40 1756 506 3.22 / 950.24 2 2
5 13 326.52 20 14.74 802 236 3.46 / 950.48 2 2
6 8 0.08 175 14.87 320 833 4.29 / 951.31 2 3
Average= 4.32
(KJ/cycle)

Cycle 218 GMT 22/ 9/2023 18:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 24 14.83 481 171 0.17 / 942.87 2 2
2 7 2006.64 42 14.11 3019 1789 1.96 / 944.66 2 2
3 13 1601.12 20 14.22 2512 714 2.67 / 945.38 2 2
4 13 1041.52 20 14.40 1776 511 3.19 / 945.89 2 2
5 13 462.68 20 14.66 1001 293 3.48 / 946.18 2 2
6 8 0.32 175 14.87 320 833 4.31 / 947.02 2 2
Average= 4.32
(KJ/cycle)

Cycle 217 GMT 12/ 9/2023 18:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 24 14.83 483 172 0.17 / 938.58 2 2
2 7 2003.28 42 14.12 3020 1791 1.96 / 940.37 2 2
3 13 1589.96 20 14.24 2486 708 2.67 / 941.08 2 2
4 13 1030.52 20 14.40 1765 508 3.18 / 941.59 2 2
5 13 457.76 20 14.67 988 290 3.47 / 941.88 2 2
6 8 -0.08 175 14.88 316 823 4.29 / 942.70 2 2
Average= 4.32
(KJ/cycle)

Cycle 216 GMT 2/ 9/2023 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 24 14.83 469 167 0.17 / 934.25 2 2
2 7 2003.60 42 14.12 3024 1793 1.96 / 936.04 2 2
3 13 1730.32 20 14.19 2690 763 2.72 / 936.81 2 2
4 13 1009.28 20 14.42 1730 499 3.22 / 937.31 2 2
5 13 442.12 20 14.68 963 283 3.51 / 937.59 2 2
6 8 0.16 175 14.88 316 823 4.33 / 938.41 2 2
Average= 4.32
(KJ/cycle)

Cycle 215 GMT 23/ 8/2023 18:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 23 14.83 474 162 0.16 / 929.86 2 2
2 7 2002.96 42 14.12 3014 1787 1.95 / 931.65 2 2
3 13 1732.56 20 14.18 2692 763 2.71 / 932.41 2 2
4 13 1150.44 20 14.36 1917 551 3.26 / 932.96 2 2
5 13 441.24 20 14.68 968 284 3.55 / 933.24 2 2
6 8 0.36 175 14.88 322 838 4.39 / 934.08 2 3
Average= 4.32
(KJ/cycle)

Cycle 214 GMT 13/ 8/2023 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 23 14.83 490 167 0.17 / 925.61 2 2
2 7 2003.20 42 14.12 3026 1795 1.96 / 927.41 2 2
3 13 1584.76 20 14.23 2497 711 2.67 / 928.12 2 2
4 13 1017.80 20 14.41 1748 504 3.18 / 928.62 2 2
5 13 324.84 20 14.74 807 238 3.41 / 928.86 2 2
6 8 -0.16 175 14.88 321 836 4.25 / 929.70 2 3
Average= 4.32
(KJ/cycle)

Cycle 213 GMT 3/ 8/2023 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 23 14.83 486 166 0.17 / 921.36 2 2
2 7 2002.92 42 14.12 3015 1788 1.95 / 923.15 2 2
3 13 1595.96 20 14.22 2510 714 2.67 / 923.86 2 2
4 13 1032.84 20 14.41 1768 510 3.18 / 924.37 2 2
5 13 330.60 20 14.74 813 240 3.42 / 924.61 2 2
6 8 0.16 175 14.88 320 833 4.25 / 925.45 2 2
Average= 4.32
(KJ/cycle)

Cycle 212 GMT 24/ 7/2023 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 23 14.84 470 160 0.16 / 917.03 2 2
2 7 2004.48 42 14.12 3019 1790 1.95 / 918.83 2 2
3 13 1592.80 20 14.23 2501 712 2.66 / 919.54 2 2
4 13 1152.28 20 14.35 1933 555 3.22 / 920.09 2 2
5 13 426.44 20 14.69 942 277 3.49 / 920.37 2 2
6 8 0.08 175 14.88 318 828 4.32 / 921.20 2 2
Average= 4.32
(KJ/cycle)

Cycle 211 GMT 14/ 7/2023 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 23 14.83 481 164 0.16 / 912.67 2 2
2 7 2002.76 43 14.12 3016 1831 2.00 / 914.50 2 2
3 13 1729.60 20 14.19 2698 766 2.76 / 915.26 2 2
4 13 1001.84 20 14.43 1718 496 3.26 / 915.76 2 2
5 13 434.20 20 14.68 955 280 3.54 / 916.04 2 2
6 8 0.20 175 14.88 321 836 4.37 / 916.87 2 2
Average= 4.32
(KJ/cycle)

Cycle 210 GMT 4/ 7/2023 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 23 14.84 473 161 0.16 / 908.34 2 2
2 7 2003.24 42 14.12 3022 1792 1.95 / 910.13 2 2
3 13 1595.68 20 14.22 2503 712 2.67 / 910.85 2 2
4 13 1015.36 20 14.42 1727 498 3.16 / 911.34 2 2
5 13 188.88 20 14.81 607 180 3.34 / 911.52 2 2
6 8 0.40 175 14.88 320 833 4.18 / 912.36 2 3
7 14 0.40 30 14.86 324 144 4.32 / 912.50 2 2
Average= 4.32
(KJ/cycle)

Cycle 209 GMT 24/ 6/2023 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 24 14.83 479 170 0.17 / 904.12 2 2
2 7 2004.24 42 14.12 3032 1798 1.97 / 905.92 2 2
3 13 1471.92 20 14.26 2352 671 2.64 / 906.59 2 2
4 13 1059.80 20 14.39 1799 518 3.16 / 907.10 2 2
5 13 340.92 20 14.73 827 244 3.40 / 907.35 2 2
6 8 -0.28 175 14.88 320 833 4.23 / 908.18 2 2
Average= 4.32
(KJ/cycle)

Cycle 208 GMT 14/ 6/2023 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 23 14.84 493 168 0.17 / 899.80 2 2
2 7 2002.04 42 14.12 3017 1789 1.96 / 901.59 2 2
3 13 1591.16 20 14.23 2509 714 2.67 / 902.31 2 2
4 13 1031.72 20 14.41 1769 510 3.18 / 902.82 2 2
5 13 450.92 20 14.67 983 288 3.47 / 903.11 2 2
6 8 0.60 175 14.87 323 841 4.31 / 903.95 2 2
Average= 4.33
(KJ/cycle)

Cycle 207 GMT 4/ 6/2023 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 24 14.84 484 172 0.17 / 895.26 2 2
2 7 2002.48 42 14.12 3025 1794 1.97 / 897.05 2 2
3 13 1589.76 20 14.23 2494 710 2.68 / 897.76 2 2
4 13 1021.64 20 14.42 1756 506 3.18 / 898.27 2 2
5 13 448.32 20 14.67 977 287 3.47 / 898.55 2 2
6 13 16.08 20 14.91 354 106 3.57 / 898.66 2 2
7 8 -0.12 175 14.87 320 833 4.41 / 899.49 2 3
8 14 -0.12 30 14.86 323 144 4.55 / 899.64 2 8
Average= 4.33
(KJ/cycle)

Cycle 206 GMT 25/ 5/2023 17:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 23 14.85 481 164 0.16 / 890.94 2 2
2 7 2002.00 42 14.13 3019 1792 1.96 / 892.74 2 2
3 13 1598.72 20 14.23 2510 714 2.67 / 893.45 2 2
4 13 1041.28 20 14.41 1773 511 3.18 / 893.96 2 2
5 13 465.48 20 14.67 996 292 3.47 / 894.25 2 2
6 8 0.12 175 14.89 319 831 4.30 / 895.08 2 4
Average= 4.32
(KJ/cycle)

Cycle 205 GMT 15/ 5/2023 17:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 23 14.85 465 159 0.16 / 886.66 2 2
2 3 1031.32 1 14.94 1869 28 0.19 / 886.69 2 2
3 7 2006.72 42 14.13 3010 1786 1.97 / 888.48 2 2
4 13 1596.08 20 14.23 2510 714 2.69 / 889.19 2 2
5 13 1046.32 20 14.41 1777 512 3.20 / 889.70 2 2
6 13 348.60 20 14.73 840 247 3.45 / 889.95 2 2
7 8 0.28 175 14.89 318 829 4.28 / 890.78 2 3
Average= 4.32
(KJ/cycle)

Cycle 204 GMT 5/ 5/2023 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 23 14.84 479 163 0.16 / 882.35 2 2
2 7 2003.12 42 14.13 3020 1792 1.96 / 884.14 2 2
3 13 1720.76 20 14.21 2669 759 2.71 / 884.90 2 2
4 13 1010.48 20 14.43 1733 500 3.21 / 885.40 2 2
5 13 433.80 20 14.69 951 279 3.49 / 885.68 2 2
6 8 0.08 175 14.88 317 825 4.32 / 886.50 2 5
Average= 4.32
(KJ/cycle)

Cycle 203 GMT 25/ 4/2023 17: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 23 14.85 488 167 0.17 / 877.98 2 2
2 7 2007.04 42 14.13 3007 1785 1.95 / 879.76 2 2
3 13 1601.32 20 14.23 2514 715 2.67 / 880.48 2 2
4 13 1037.80 20 14.41 1777 512 3.18 / 880.99 2 2
5 13 324.72 20 14.74 808 238 3.42 / 881.23 2 2
6 13 38.84 20 14.89 391 116 3.53 / 881.34 2 2
7 8 -0.08 175 14.87 324 843 4.38 / 882.19 2 7
Average= 4.32
(KJ/cycle)

Cycle 202 GMT 15/ 4/2023 16:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 23 14.85 468 160 0.16 / 873.74 2 2
2 7 2004.08 42 14.12 3026 1795 1.95 / 875.53 2 2
3 13 1585.20 20 14.23 2494 710 2.66 / 876.24 2 2
4 13 1013.40 20 14.42 1739 502 3.17 / 876.74 2 2
5 13 304.12 20 14.76 775 229 3.39 / 876.97 2 2
6 8 0.48 175 14.89 321 836 4.23 / 877.81 2 4
Average= 4.32
(KJ/cycle)

Cycle 201 GMT 5/ 4/2023 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 23 14.85 479 164 0.16 / 869.06 2 2
2 5 1300.40 8 14.57 2222 259 0.42 / 869.32 2 2
3 7 2006.00 42 14.11 3033 1797 2.22 / 871.11 2 2
4 13 1599.84 20 14.22 2520 717 2.94 / 871.83 2 2
5 13 1030.88 20 14.41 1763 508 3.44 / 872.34 2 2
6 13 459.44 20 14.67 997 293 3.74 / 872.63 2 2
7 13 32.08 20 14.90 377 112 3.85 / 872.74 2 2
8 8 0.16 175 14.88 320 833 4.68 / 873.58 2 2
Average= 4.32
(KJ/cycle)

Cycle 200 GMT 26/ 3/2023 16:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 23 14.86 473 162 0.16 / 864.64 2 2
2 7 2003.92 42 14.13 3021 1793 1.95 / 866.44 2 2
3 13 1596.68 20 14.23 2511 715 2.67 / 867.15 2 2
4 13 1029.48 20 14.42 1770 510 3.18 / 867.66 2 2
5 13 444.96 20 14.68 977 287 3.47 / 867.95 2 2
6 13 30.84 20 14.90 377 112 3.58 / 868.06 2 2
7 8 0.08 175 14.88 320 833 4.41 / 868.89 2 5
Average= 4.32
(KJ/cycle)

Cycle 199 GMT 16/ 3/2023 16:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 24 14.85 483 172 0.17 / 860.06 2 2
2 3 951.16 -1 15.34 0 0 0.00 / 860.06 2 2
3 5 1301.32 8 14.58 2214 258 0.43 / 860.32 2 2
4 7 2003.36 42 14.12 3011 1786 2.22 / 862.10 2 2
5 13 1728.04 20 14.19 2667 757 2.97 / 862.86 2 2
6 13 1016.96 20 14.43 1740 502 3.48 / 863.36 2 2
7 13 449.64 20 14.68 983 289 3.76 / 863.65 2 2
8 8 0.40 175 14.89 319 831 4.59 / 864.48 2 2
Average= 4.32
(KJ/cycle)

Cycle 198 GMT 6/ 3/2023 16: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 23 14.85 472 161 0.16 / 855.73 2 2
2 7 2004.36 42 14.13 3023 1794 1.96 / 857.53 2 2
3 13 1484.28 20 14.27 2370 676 2.63 / 858.20 2 2
4 13 944.24 20 14.46 1649 477 3.11 / 858.68 2 2
5 13 377.20 20 14.71 878 258 3.37 / 858.94 2 2
6 13 46.76 20 14.89 402 120 3.49 / 859.06 2 2
7 8 0.12 175 14.88 319 831 4.32 / 859.89 2 2
Average= 4.32
(KJ/cycle)

Cycle 197 GMT 24/ 2/2023 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 23 14.84 487 166 0.17 / 851.34 2 2
2 7 2002.48 42 14.13 3016 1790 1.96 / 853.13 2 2
3 13 1595.08 20 14.24 2508 714 2.67 / 853.84 2 2
4 13 1019.08 20 14.43 1750 505 3.18 / 854.34 2 2
5 13 442.72 20 14.69 970 285 3.46 / 854.63 2 2
6 13 30.12 20 14.91 378 113 3.57 / 854.74 2 2
7 8 0.16 175 14.88 318 828 4.40 / 855.57 2 3
Average= 4.32
(KJ/cycle)

Cycle 196 GMT 14/ 2/2023 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 23 14.86 478 163 0.16 / 846.89 2 2
2 7 2009.76 42 14.13 3022 1793 1.96 / 848.69 2 2
3 13 1601.04 20 14.24 2515 716 2.67 / 849.40 2 2
4 13 1035.12 20 14.42 1772 511 3.18 / 849.92 2 2
5 13 459.36 20 14.67 1000 293 3.48 / 850.21 2 2
6 13 31.48 20 14.90 382 114 3.59 / 850.32 2 2
7 8 0.20 175 14.88 325 846 4.44 / 851.17 2 2
Average= 4.32
(KJ/cycle)

Cycle 195 GMT 4/ 2/2023 15:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 23 14.86 472 161 0.16 / 842.44 2 2
2 7 2001.92 42 14.14 3016 1791 1.95 / 844.23 2 2
3 13 1725.96 20 14.21 2692 765 2.72 / 845.00 2 2
4 13 1008.08 20 14.43 1734 500 3.22 / 845.50 2 2
5 13 438.96 20 14.69 967 284 3.50 / 845.78 2 2
6 13 15.52 20 14.92 355 106 3.61 / 845.89 2 2
7 8 0.16 175 14.88 323 841 4.45 / 846.73 2 6
Average= 4.32
(KJ/cycle)

Cycle 194 GMT 25/ 1/2023 15:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 23 14.85 472 161 0.16 / 838.07 2 2
2 7 2005.76 42 14.13 3027 1796 1.96 / 839.87 2 2
3 13 1607.92 20 14.23 2528 719 2.68 / 840.59 2 2
4 13 1036.32 20 14.42 1779 513 3.19 / 841.10 2 2
5 13 328.88 20 14.75 813 240 3.43 / 841.34 2 2
6 13 20.76 20 14.92 361 108 3.54 / 841.45 2 2
7 8 -0.08 175 14.89 320 834 4.37 / 842.28 2 9
Average= 4.32
(KJ/cycle)

Cycle 193 GMT 15/ 1/2023 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 23 14.85 479 164 0.16 / 833.63 2 2
2 7 2006.40 43 14.13 3013 1831 1.99 / 835.46 2 2
3 13 1594.56 20 14.24 2503 713 2.71 / 836.18 2 2
4 13 1024.40 20 14.43 1752 506 3.21 / 836.68 2 2
5 13 442.72 20 14.69 972 286 3.50 / 836.97 2 2
6 13 14.80 20 14.92 354 106 3.60 / 837.07 2 2
7 8 0.24 175 14.88 322 838 4.44 / 837.91 2 3
Average= 4.32
(KJ/cycle)

Cycle 192 GMT 5/ 1/2023 15:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 23 14.84 485 166 0.17 / 829.14 2 2
2 7 2002.88 42 14.14 3016 1791 1.96 / 830.94 2 2
3 13 1729.48 20 14.21 2676 761 2.72 / 831.70 2 2
4 13 1133.60 20 14.38 1898 546 3.26 / 832.24 2 2
5 13 421.04 20 14.70 946 278 3.54 / 832.52 2 2
6 13 28.76 20 14.91 377 112 3.65 / 832.63 2 2
7 8 -0.20 175 14.88 321 836 4.49 / 833.47 2 2
Average= 4.32
(KJ/cycle)

Cycle 191 GMT 26/12/2022 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 23 14.85 485 166 0.17 / 824.77 2 2
2 7 2004.56 42 14.14 3023 1795 1.96 / 826.56 2 2
3 13 1597.08 20 14.24 2519 717 2.68 / 827.28 2 2
4 13 1031.88 20 14.42 1757 507 3.19 / 827.78 2 2
5 13 343.56 20 14.74 830 245 3.43 / 828.03 2 2
6 13 20.32 20 14.92 363 108 3.54 / 828.14 2 2
7 8 0.28 175 14.88 323 841 4.38 / 828.98 2 5
Average= 4.32
(KJ/cycle)

Cycle 190 GMT 16/12/2022 14:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 23 14.85 485 166 0.17 / 820.41 2 2
2 7 2001.88 42 14.14 3015 1791 1.96 / 822.20 2 2
3 13 1595.16 20 14.24 2496 711 2.67 / 822.91 2 2
4 13 1030.16 20 14.43 1750 505 3.17 / 823.41 2 2
5 13 321.48 20 14.75 796 235 3.41 / 823.65 2 2
6 13 35.60 20 14.91 384 115 3.52 / 823.76 2 2
7 8 0.12 175 14.88 321 836 4.36 / 824.60 2 4
Average= 4.32
(KJ/cycle)

Cycle 189 GMT 6/12/2022 14:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 23 14.85 477 163 0.16 / 815.89 2 2
2 5 1301.56 8 14.59 2209 258 0.42 / 816.14 2 2
3 7 2009.24 42 14.12 3018 1790 2.21 / 817.93 2 2
4 13 1609.00 20 14.23 2517 716 2.93 / 818.65 2 2
5 13 1043.68 20 14.42 1769 510 3.44 / 819.16 2 2
6 13 347.96 20 14.74 840 248 3.68 / 819.41 2 2
7 8 -0.08 175 14.90 320 834 4.52 / 820.24 2 4
Average= 4.32
(KJ/cycle)

Cycle 188 GMT 26/11/2022 13:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 23 14.84 489 167 0.17 / 811.57 2 2
2 7 2004.76 42 14.14 3007 1786 1.95 / 813.36 2 2
3 13 1597.88 20 14.24 2514 716 2.67 / 814.08 2 2
4 13 1035.24 20 14.43 1770 511 3.18 / 814.59 2 2
5 13 451.72 20 14.69 985 289 3.47 / 814.88 2 2
6 8 0.36 175 14.89 325 847 4.32 / 815.72 2 2
Average= 4.32
(KJ/cycle)

Cycle 187 GMT 16/11/2022 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 23 14.84 479 163 0.16 / 806.89 2 2
2 5 1303.52 8 14.60 2217 259 0.42 / 807.15 2 2
3 7 2006.08 42 14.13 3028 1797 2.22 / 808.95 2 2
4 13 1596.56 20 14.23 2515 716 2.94 / 809.66 2 2
5 13 1037.00 20 14.43 1774 512 3.45 / 810.17 2 2
6 13 454.52 20 14.69 981 288 3.74 / 810.46 2 2
7 13 30.88 20 14.92 376 112 3.85 / 810.57 2 2
8 8 0.12 175 14.89 320 834 4.68 / 811.41 2 2
Average= 4.32
(KJ/cycle)

Cycle 186 GMT 6/11/2022 13:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 23 14.85 484 165 0.17 / 802.49 2 2
2 7 2005.24 42 14.14 3009 1787 1.95 / 804.27 2 2
3 13 1592.80 20 14.25 2503 713 2.67 / 804.99 2 2
4 13 1027.20 20 14.44 1753 506 3.17 / 805.49 2 2
5 13 452.20 20 14.69 981 288 3.46 / 805.78 2 2
6 13 30.04 20 14.92 374 112 3.57 / 805.89 2 2
7 8 0.04 175 14.89 320 834 4.41 / 806.73 2 4
Average= 4.31
(KJ/cycle)

Cycle 185 GMT 27/10/2022 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 23 14.85 488 167 0.17 / 798.23 2 2
2 7 2003.20 42 14.14 3009 1787 1.95 / 800.02 2 2
3 13 1599.72 20 14.25 2508 715 2.67 / 800.73 2 2
4 13 1032.08 20 14.43 1764 509 3.18 / 801.24 2 2
5 13 329.52 20 14.76 815 241 3.42 / 801.48 2 2
6 8 0.08 175 14.89 322 839 4.26 / 802.32 2 2
Average= 4.31
(KJ/cycle)

Cycle 184 GMT 17/10/2022 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 22 14.84 491 160 0.16 / 793.91 2 2
2 7 2008.56 42 14.14 3025 1796 1.96 / 795.71 2 2
3 13 1594.60 20 14.25 2507 714 2.67 / 796.42 2 2
4 13 1031.52 20 14.43 1765 509 3.18 / 796.93 2 2
5 13 454.36 20 14.69 987 290 3.47 / 797.22 2 2
6 8 0.08 175 14.89 324 844 4.31 / 798.06 2 3
Average= 4.31
(KJ/cycle)

Cycle 183 GMT 7/10/2022 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 23 14.85 475 162 0.16 / 789.63 2 2
2 7 2002.08 42 14.15 3011 1789 1.95 / 791.41 2 2
3 13 1602.92 20 14.25 2512 716 2.67 / 792.13 2 2
4 13 914.40 20 14.48 1604 465 3.13 / 792.60 2 2
5 13 489.60 20 14.67 1035 304 3.44 / 792.90 2 2
6 8 0.28 175 14.89 326 849 4.29 / 793.75 2 2
Average= 4.31
(KJ/cycle)

Cycle 182 GMT 27/ 9/2022 13:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 23 14.84 487 166 0.17 / 785.28 2 2
2 7 2004.52 42 14.15 3003 1785 1.95 / 787.06 2 2
3 13 1588.28 20 14.27 2491 711 2.66 / 787.78 2 2
4 13 1018.00 20 14.44 1740 503 3.16 / 788.28 2 2
5 13 302.72 20 14.78 769 227 3.39 / 788.51 2 2
6 13 13.84 20 14.93 353 105 3.50 / 788.61 2 2
7 8 0.00 175 14.89 327 852 4.35 / 789.46 2 2
Average= 4.31
(KJ/cycle)

Cycle 181 GMT 17/ 9/2022 13:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 23 14.84 492 168 0.17 / 780.92 2 2
2 7 2002.40 42 14.15 3005 1786 1.95 / 782.71 2 2
3 13 1590.12 20 14.26 2494 711 2.67 / 783.42 2 2
4 13 1026.84 20 14.44 1739 502 3.17 / 783.92 2 2
5 13 323.80 20 14.77 804 238 3.40 / 784.16 2 2
6 13 17.96 20 14.93 363 108 3.51 / 784.26 2 2
7 8 0.08 175 14.89 326 849 4.36 / 785.11 2 3
Average= 4.31
(KJ/cycle)

Cycle 180 GMT 7/ 9/2022 13:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 23 14.84 489 167 0.17 / 776.35 2 2
2 5 1304.00 8 14.59 2201 257 0.42 / 776.61 2 2
3 7 2007.28 42 14.13 3016 1790 2.21 / 778.40 2 2
4 13 1596.60 20 14.24 2498 711 2.93 / 779.11 2 2
5 13 1029.20 20 14.43 1754 506 3.43 / 779.62 2 2
6 13 445.28 20 14.70 971 285 3.72 / 779.90 2 2
7 8 0.28 175 14.89 326 849 4.57 / 780.75 2 5
Average= 4.31
(KJ/cycle)

Cycle 179 GMT 28/ 8/2022 13: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 23 14.85 491 168 0.17 / 771.90 2 2
2 7 2005.44 43 14.15 3002 1827 1.99 / 773.73 2 2
3 13 1597.44 20 14.25 2519 718 2.71 / 774.44 2 2
4 13 1031.76 20 14.43 1759 508 3.22 / 774.95 2 2
5 13 320.20 20 14.77 798 236 3.46 / 775.19 2 2
6 8 -0.04 175 14.90 326 850 4.31 / 776.04 2 2
7 14 -0.04 30 14.88 329 147 4.45 / 776.19 2 3
Average= 4.31
(KJ/cycle)

Cycle 178 GMT 18/ 8/2022 12:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 23 14.85 487 166 0.17 / 767.66 2 2
2 7 2005.76 42 14.15 3000 1783 1.95 / 769.44 2 2
3 13 1596.16 20 14.26 2482 708 2.66 / 770.15 2 2
4 13 1021.96 20 14.44 1746 504 3.16 / 770.65 2 2
5 13 327.12 20 14.77 802 237 3.40 / 770.89 2 2
6 8 0.36 175 14.90 324 845 4.24 / 771.73 2 6
Average= 4.31
(KJ/cycle)

Cycle 177 GMT 8/ 8/2022 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 22 14.85 487 159 0.16 / 763.33 2 2
2 7 2005.20 42 14.16 2971 1767 1.93 / 765.10 2 2
3 13 1731.52 20 14.22 2667 758 2.68 / 765.86 2 2
4 13 1020.84 20 14.44 1744 504 3.19 / 766.36 2 2
5 13 447.52 20 14.70 975 287 3.47 / 766.65 2 2
6 8 -0.08 175 14.90 323 842 4.32 / 767.49 2 2
Average= 4.31
(KJ/cycle)

Cycle 176 GMT 29/ 7/2022 12:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 23 14.84 495 169 0.17 / 758.97 2 2
2 7 2002.36 42 14.16 2995 1781 1.95 / 760.75 2 2
3 13 1727.64 20 14.23 2667 759 2.71 / 761.51 2 2
4 13 1138.64 20 14.40 1884 543 3.25 / 762.05 2 2
5 13 417.48 20 14.72 939 276 3.53 / 762.33 2 2
6 8 0.24 175 14.90 324 845 4.37 / 763.17 2 2
Average= 4.31
(KJ/cycle)

Cycle 175 GMT 19/ 7/2022 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 23 14.86 484 165 0.17 / 754.55 2 2
2 7 2003.24 42 14.15 3003 1785 1.95 / 756.33 2 2
3 13 1596.28 20 14.26 2497 712 2.66 / 757.04 2 2
4 13 1030.96 20 14.44 1767 510 3.17 / 757.55 2 2
5 13 452.60 20 14.69 989 291 3.46 / 757.84 2 2
6 13 33.72 20 14.92 378 113 3.58 / 757.96 2 2
7 8 0.04 175 14.89 323 842 4.42 / 758.80 2 3
Average= 4.31
(KJ/cycle)

Cycle 174 GMT 9/ 7/2022 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 22 14.87 478 156 0.16 / 750.24 2 2
2 7 2005.20 42 14.15 3014 1791 1.95 / 752.03 2 2
3 13 1591.36 20 14.26 2494 711 2.66 / 752.74 2 2
4 13 1029.68 20 14.45 1757 508 3.17 / 753.25 2 2
5 13 450.36 20 14.70 981 288 3.46 / 753.54 2 2
6 8 0.04 175 14.90 323 842 4.30 / 754.38 2 2
Average= 4.31
(KJ/cycle)

Cycle 173 GMT 29/ 6/2022 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 23 14.86 485 166 0.17 / 745.95 2 2
2 3 968.04 -1 15.36 0 0 0.00 / 745.95 2 2
3 7 2001.72 42 14.15 3016 1792 1.96 / 747.75 2 2
4 13 1731.80 20 14.22 2690 765 2.72 / 748.51 2 2
5 13 1014.96 20 14.45 1741 503 3.23 / 749.02 2 2
6 13 311.68 20 14.78 784 232 3.46 / 749.25 2 2
7 8 0.12 175 14.91 321 838 4.30 / 750.08 2 4
Average= 4.31
(KJ/cycle)

Cycle 172 GMT 19/ 6/2022 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 22 14.87 479 157 0.16 / 741.63 2 2
2 3 1053.28 1 14.87 1913 28 0.19 / 741.66 2 2
3 7 2004.92 42 14.14 3016 1791 1.98 / 743.45 2 2
4 13 1589.20 20 14.26 2499 713 2.69 / 744.16 2 2
5 13 1016.68 20 14.45 1741 503 3.19 / 744.67 2 2
6 13 427.76 20 14.71 954 281 3.47 / 744.95 2 2
7 8 0.20 175 14.90 323 842 4.32 / 745.79 2 2
Average= 4.31
(KJ/cycle)

Cycle 171 GMT 9/ 6/2022 11:40:32

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 22 14.87 482 158 0.16 / 737.33 2 2
2 7 2005.84 42 14.15 3000 1783 1.94 / 739.11 2 2
3 13 1607.20 20 14.26 2517 718 2.66 / 739.83 2 2
4 13 1045.16 20 14.44 1779 514 3.17 / 740.34 2 2
5 13 461.32 20 14.70 997 293 3.47 / 740.64 2 2
6 8 -0.04 175 14.91 321 838 4.30 / 741.47 2 2
Average= 4.31
(KJ/cycle)

Cycle 170 GMT 30/ 5/2022 11:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 23 14.87 479 164 0.16 / 733.08 2 2
2 3 959.08 -1 15.36 0 0 0.00 / 733.08 2 2
3 7 2003.88 42 14.15 3012 1790 1.95 / 734.87 2 2
4 13 1597.72 20 14.26 2515 717 2.67 / 735.59 2 2
5 13 1023.04 20 14.45 1760 509 3.18 / 736.10 2 2
6 13 313.08 20 14.78 790 234 3.41 / 736.33 2 2
7 8 0.44 175 14.91 322 840 4.25 / 737.17 2 4
Average= 4.31
(KJ/cycle)

Cycle 169 GMT 20/ 5/2022 11:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 22 14.87 484 158 0.16 / 728.71 2 2
2 7 2002.80 42 14.15 3017 1793 1.95 / 730.50 2 2
3 13 1592.92 20 14.26 2503 714 2.67 / 731.22 2 2
4 13 1030.56 20 14.44 1762 509 3.17 / 731.73 2 2
5 13 323.68 20 14.77 805 238 3.41 / 731.96 2 2
6 13 40.52 20 14.93 392 117 3.53 / 732.08 2 2
7 8 0.04 175 14.90 321 837 4.37 / 732.92 2 3
Average= 4.31
(KJ/cycle)

Cycle 168 GMT 10/ 5/2022 10:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 22 14.88 472 155 0.15 / 724.36 2 2
2 7 2004.76 42 14.15 3019 1794 1.95 / 726.16 2 2
3 13 1596.28 20 14.27 2512 717 2.67 / 726.87 2 2
4 13 1163.60 20 14.39 1936 557 3.22 / 727.43 2 2
5 13 428.80 20 14.71 956 281 3.50 / 727.71 2 2
6 8 0.08 175 14.91 322 840 4.34 / 728.55 2 4
Average= 4.31
(KJ/cycle)

Cycle 167 GMT 30/ 4/2022 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 22 14.88 481 157 0.16 / 720.24 2 2
2 7 2006.84 42 14.15 3024 1797 1.95 / 722.03 2 2
3 13 1469.88 20 14.30 2340 669 2.62 / 722.70 2 2
4 13 930.88 20 14.48 1627 471 3.10 / 723.18 2 2
5 13 244.76 20 14.81 692 205 3.30 / 723.38 2 2
6 8 0.20 175 14.91 317 827 4.13 / 724.21 2 3
Average= 4.31
(KJ/cycle)

Cycle 166 GMT 20/ 4/2022 10:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 22 14.88 479 157 0.16 / 715.99 2 2
2 3 1021.64 1 15.02 1880 28 0.19 / 716.02 2 2
3 7 2003.84 42 14.15 3011 1789 1.97 / 717.81 2 2
4 13 1582.28 20 14.26 2489 710 2.68 / 718.52 2 2
5 13 1021.68 20 14.45 1746 505 3.19 / 719.02 2 2
6 13 311.92 20 14.79 784 232 3.42 / 719.26 2 2
7 8 0.16 175 14.92 316 825 4.25 / 720.08 2 4
Average= 4.31
(KJ/cycle)

Cycle 165 GMT 10/ 4/2022 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 23 14.87 471 161 0.16 / 711.68 2 2
2 3 953.64 -1 15.36 0 0 0.00 / 711.68 2 2
3 7 2006.00 42 14.15 3027 1799 1.96 / 713.48 2 2
4 13 1599.88 20 14.26 2524 720 2.68 / 714.20 2 2
5 13 1036.64 20 14.45 1762 509 3.19 / 714.71 2 2
6 13 453.88 20 14.70 986 290 3.48 / 715.00 2 2
7 8 0.20 175 14.92 320 836 4.31 / 715.83 2 3
Average= 4.31
(KJ/cycle)

Cycle 164 GMT 31/ 3/2022 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 22 14.88 478 156 0.16 / 707.24 2 2
2 3 1041.60 1 14.93 1886 28 0.18 / 707.27 2 2
3 7 2007.52 42 14.16 3025 1799 1.98 / 709.07 2 2
4 13 1604.76 20 14.26 2534 723 2.71 / 709.79 2 2
5 13 914.04 20 14.50 1607 466 3.17 / 710.26 2 2
6 13 496.40 20 14.68 1042 306 3.48 / 710.56 2 2
7 13 35.84 20 14.93 386 115 3.59 / 710.68 2 2
8 8 0.04 175 14.90 322 840 4.43 / 711.52 2 3
Average= 4.31
(KJ/cycle)

Cycle 163 GMT 21/ 3/2022 9:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 23 14.87 477 163 0.16 / 702.90 2 2
2 3 968.20 -1 15.36 0 0 0.00 / 702.90 2 2
3 3 1018.40 1 15.05 1878 28 0.19 / 702.93 2 2
4 7 2004.16 42 14.16 3019 1795 1.99 / 704.73 2 2
5 13 1596.60 20 14.26 2511 716 2.70 / 705.44 2 2
6 13 1033.20 20 14.45 1766 510 3.21 / 705.95 2 2
7 13 460.32 20 14.71 995 293 3.51 / 706.25 2 2
8 8 0.16 175 14.92 322 841 4.35 / 707.09 2 4
Average= 4.31
(KJ/cycle)

Cycle 162 GMT 11/ 3/2022 9:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 22 14.88 480 157 0.16 / 698.50 2 2
2 7 2003.80 43 14.16 3012 1834 1.99 / 700.34 2 2
3 13 1596.28 20 14.26 2512 716 2.71 / 701.05 2 2
4 13 1021.56 20 14.45 1751 506 3.21 / 701.56 2 2
5 13 307.52 20 14.79 781 231 3.44 / 701.79 2 2
6 13 32.48 20 14.94 379 113 3.56 / 701.90 2 2
7 8 0.24 175 14.91 320 835 4.39 / 702.74 2 4
Average= 4.31
(KJ/cycle)

Cycle 161 GMT 1/ 3/2022 8:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 23 14.88 471 161 0.16 / 694.07 2 2
2 3 973.32 -1 15.37 0 0 0.00 / 694.07 2 2
3 3 1029.44 1 15.02 1885 28 0.19 / 694.10 2 2
4 7 2005.20 42 14.15 3030 1801 1.99 / 695.90 2 2
5 13 1734.20 20 14.23 2691 766 2.76 / 696.67 2 2
6 13 1010.52 20 14.47 1728 500 3.26 / 697.17 2 2
7 13 308.44 20 14.79 778 230 3.49 / 697.40 2 2
8 13 33.48 20 14.94 378 113 3.60 / 697.51 2 2
9 8 0.12 175 14.91 320 835 4.43 / 698.35 2 3
Average= 4.31
(KJ/cycle)

Cycle 160 GMT 19/ 2/2022 8:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 23 14.88 466 159 0.16 / 689.48 2 2
2 3 971.60 -1 15.37 0 0 0.00 / 689.48 2 2
3 3 1025.84 1 15.04 1855 28 0.19 / 689.51 2 2
4 5 1304.76 8 14.60 2209 258 0.45 / 689.76 2 2
5 7 2005.12 42 14.15 2995 1780 2.23 / 691.54 2 2
6 13 1594.00 20 14.26 2509 716 2.94 / 692.26 2 2
7 13 896.60 20 14.51 1576 457 3.40 / 692.72 2 2
8 13 336.60 20 14.78 818 242 3.64 / 692.96 2 2
9 13 38.12 20 14.93 390 116 3.76 / 693.08 2 2
10 8 0.08 175 14.91 321 838 4.59 / 693.91 2 3
Average= 4.31
(KJ/cycle)

Cycle 159 GMT 9/ 2/2022 8:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 23 14.88 485 166 0.17 / 685.07 2 2
2 7 2006.00 42 14.16 3014 1792 1.96 / 686.87 2 2
3 13 1595.48 20 14.27 2501 714 2.67 / 687.58 2 2
4 13 1025.88 20 14.46 1753 507 3.18 / 688.09 2 2
5 13 449.72 20 14.72 976 287 3.47 / 688.37 2 2
6 13 31.16 20 14.94 374 112 3.58 / 688.49 2 2
7 8 0.04 175 14.91 319 832 4.41 / 689.32 2 3
Average= 4.31
(KJ/cycle)

Cycle 158 GMT 30/ 1/2022 8:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 23 14.88 487 167 0.17 / 680.81 2 2
2 7 2004.72 42 14.16 3024 1798 1.97 / 682.60 2 2
3 13 1600.36 20 14.26 2513 717 2.68 / 683.32 2 2
4 13 1030.72 20 14.45 1755 507 3.19 / 683.83 2 2
5 13 325.52 20 14.78 807 239 3.43 / 684.07 2 2
6 8 0.20 175 14.92 322 841 4.27 / 684.91 2 4
Average= 4.31
(KJ/cycle)

Cycle 157 GMT 20/ 1/2022 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 23 14.88 479 164 0.16 / 676.49 2 2
2 7 2001.88 42 14.16 3017 1794 1.96 / 678.28 2 2
3 13 1587.52 20 14.27 2501 714 2.67 / 678.99 2 2
4 13 1036.12 20 14.45 1775 513 3.18 / 679.51 2 2
5 13 451.72 20 14.72 984 290 3.47 / 679.80 2 2
6 8 0.20 175 14.92 323 843 4.32 / 680.64 2 2
Average= 4.31
(KJ/cycle)

Cycle 156 GMT 10/ 1/2022 8: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 23 14.88 490 168 0.17 / 671.96 2 2
2 5 1300.72 8 14.62 2217 259 0.43 / 672.22 2 2
3 7 2004.72 42 14.15 3016 1792 2.22 / 674.01 2 2
4 13 1597.40 20 14.27 2514 717 2.94 / 674.73 2 2
5 13 1030.80 20 14.46 1758 508 3.45 / 675.24 2 2
6 13 320.52 20 14.79 800 237 3.68 / 675.47 2 2
7 8 0.16 175 14.92 325 849 4.53 / 676.32 2 2
Average= 4.31
(KJ/cycle)

Cycle 155 GMT 31/12/2021 7:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 23 14.89 482 165 0.17 / 667.62 2 2
2 7 2003.60 42 14.16 3015 1793 1.96 / 669.41 2 2
3 13 1463.48 20 14.31 2334 668 2.63 / 670.08 2 2
4 13 1043.28 20 14.44 1782 515 3.14 / 670.59 2 2
5 13 328.08 20 14.78 811 240 3.38 / 670.83 2 2
6 13 19.08 20 14.95 363 109 3.49 / 670.94 2 2
7 8 -0.12 175 14.91 325 848 4.34 / 671.79 2 3
Average= 4.31
(KJ/cycle)

Cycle 154 GMT 21/12/2021 7:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 23 14.89 483 165 0.17 / 663.29 2 2
2 7 2003.44 42 14.17 3016 1795 1.96 / 665.08 2 2
3 13 1596.24 20 14.27 2508 716 2.68 / 665.80 2 2
4 13 1034.00 20 14.46 1765 510 3.19 / 666.31 2 2
5 13 464.00 20 14.72 1000 294 3.48 / 666.60 2 2
6 8 0.16 175 14.93 325 849 4.33 / 667.45 2 3
Average= 4.31
(KJ/cycle)

Cycle 153 GMT 11/12/2021 7:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 23 14.88 490 168 0.17 / 659.02 2 2
2 7 2006.28 42 14.17 3019 1797 1.96 / 660.82 2 2
3 13 1597.40 20 14.28 2507 716 2.68 / 661.53 2 2
4 13 1033.96 20 14.46 1762 510 3.19 / 662.04 2 2
5 13 318.36 20 14.80 797 236 3.43 / 662.28 2 2
6 8 0.48 175 14.93 324 847 4.27 / 663.12 2 3
Average= 4.31
(KJ/cycle)

Cycle 152 GMT 1/12/2021 7:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 23 14.88 482 165 0.16 / 654.74 2 2
2 7 2003.16 42 14.17 3014 1794 1.96 / 656.53 2 2
3 13 1603.80 20 14.27 2521 719 2.68 / 657.25 2 2
4 13 1038.92 20 14.46 1773 513 3.19 / 657.76 2 2
5 13 327.76 20 14.79 810 240 3.43 / 658.00 2 2
6 8 0.20 175 14.92 325 849 4.28 / 658.85 2 3
Average= 4.31
(KJ/cycle)

Cycle 151 GMT 21/11/2021 7:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 23 14.87 501 171 0.17 / 650.44 2 2
2 7 2007.16 42 14.17 3021 1798 1.97 / 652.24 2 2
3 13 1609.68 20 14.27 2527 721 2.69 / 652.96 2 2
4 13 1043.88 20 14.46 1769 512 3.20 / 653.47 2 2
5 13 336.72 20 14.79 822 243 3.45 / 653.72 2 2
6 8 0.16 175 14.93 327 854 4.30 / 654.57 2 3
Average= 4.31
(KJ/cycle)

Cycle 150 GMT 11/11/2021 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 23 14.87 494 169 0.17 / 646.14 2 2
2 7 2007.28 42 14.16 3025 1799 1.97 / 647.94 2 2
3 13 1603.84 20 14.28 2527 722 2.69 / 648.67 2 2
4 13 1034.32 20 14.46 1763 510 3.20 / 649.18 2 2
5 13 322.40 20 14.80 805 238 3.44 / 649.41 2 2
6 8 0.16 175 14.92 329 859 4.30 / 650.27 2 4
Average= 4.31
(KJ/cycle)

Cycle 149 GMT 1/11/2021 7: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 23 14.87 495 169 0.17 / 641.56 2 2
2 5 1301.24 8 14.61 2229 261 0.43 / 641.82 2 2
3 7 2004.56 42 14.14 3027 1798 2.23 / 643.61 2 2
4 13 1730.88 20 14.23 2677 762 2.99 / 644.38 2 2
5 13 1021.56 20 14.47 1747 506 3.49 / 644.88 2 2
6 13 306.88 20 14.80 786 233 3.73 / 645.11 2 2
7 8 -0.12 175 14.93 330 862 4.59 / 645.98 2 2
Average= 4.31
(KJ/cycle)

Cycle 148 GMT 22/10/2021 6:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 23 14.87 490 168 0.17 / 637.27 2 2
2 7 2003.88 42 14.17 3012 1793 1.96 / 639.06 2 2
3 13 1587.64 20 14.29 2506 716 2.68 / 639.78 2 2
4 13 1030.08 20 14.47 1757 508 3.18 / 640.29 2 2
5 13 303.84 20 14.80 779 231 3.42 / 640.52 2 2
6 8 0.40 175 14.92 333 869 4.28 / 641.39 2 3
Average= 4.30
(KJ/cycle)

Cycle 147 GMT 12/10/2021 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 23 14.87 503 172 0.17 / 632.84 2 2
2 7 2004.84 42 14.17 3013 1793 1.97 / 634.63 2 2
3 13 1586.72 20 14.28 2498 713 2.68 / 635.34 2 2
4 13 1016.84 20 14.47 1737 503 3.18 / 635.85 2 2
5 13 437.88 20 14.73 968 285 3.47 / 636.13 2 2
6 13 15.96 20 14.96 363 109 3.58 / 636.24 2 2
7 8 -0.40 175 14.92 330 862 4.44 / 637.10 2 5
Average= 4.30
(KJ/cycle)

Cycle 146 GMT 2/10/2021 6:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 23 14.87 495 169 0.17 / 628.45 2 2
2 7 2004.44 42 14.17 3005 1788 1.96 / 630.24 2 2
3 13 1599.28 20 14.28 2507 716 2.67 / 630.95 2 2
4 13 1033.00 20 14.46 1757 508 3.18 / 631.46 2 2
5 13 594.72 20 14.65 1173 344 3.53 / 631.80 2 2
6 8 0.32 175 14.92 330 862 4.39 / 632.66 2 2
Average= 4.30
(KJ/cycle)

Cycle 145 GMT 22/ 9/2021 6:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 23 14.87 505 173 0.17 / 623.75 2 2
2 5 1307.24 8 14.60 2224 260 0.43 / 624.01 2 2
3 7 2001.88 42 14.15 3013 1791 2.22 / 625.80 2 2
4 13 1595.48 20 14.28 2515 718 2.94 / 626.52 2 2
5 13 1027.96 20 14.46 1760 509 3.45 / 627.03 2 2
6 13 441.84 20 14.73 970 286 3.74 / 627.31 2 2
7 13 14.36 20 14.96 359 107 3.84 / 627.42 2 2
8 8 0.08 175 14.92 328 856 4.70 / 628.28 2 2
Average= 4.30
(KJ/cycle)

Cycle 144 GMT 12/ 9/2021 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 23 14.88 492 168 0.17 / 619.44 2 2
2 7 2004.24 42 14.18 3002 1788 1.96 / 621.23 2 2
3 13 1723.84 20 14.25 2666 760 2.72 / 621.99 2 2
4 13 998.68 20 14.49 1718 498 3.21 / 622.49 2 2
5 13 289.92 20 14.82 756 224 3.44 / 622.71 2 2
6 8 0.16 175 14.93 331 865 4.30 / 623.58 2 2
Average= 4.30
(KJ/cycle)

Cycle 143 GMT 2/ 9/2021 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 23 14.87 499 171 0.17 / 615.11 2 2
2 7 2004.76 42 14.17 3013 1793 1.96 / 616.91 2 2
3 13 1587.64 20 14.29 2493 712 2.68 / 617.62 2 2
4 13 1021.16 20 14.47 1743 504 3.18 / 618.12 2 2
5 13 436.96 20 14.74 967 285 3.47 / 618.41 2 2
6 8 -0.12 175 14.93 332 867 4.33 / 619.27 2 3
Average= 4.30
(KJ/cycle)

Cycle 142 GMT 23/ 8/2021 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 23 14.87 498 170 0.17 / 610.76 2 2
2 7 2014.84 42 14.17 3028 1802 1.97 / 612.56 2 2
3 13 1605.36 20 14.29 2517 719 2.69 / 613.28 2 2
4 13 1171.36 20 14.41 1940 559 3.25 / 613.84 2 2
5 13 311.20 20 14.81 787 233 3.48 / 614.07 2 2
6 8 0.24 175 14.93 332 867 4.35 / 614.94 2 3
Average= 4.30
(KJ/cycle)

Cycle 141 GMT 13/ 8/2021 6:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 23 14.88 488 167 0.17 / 606.17 2 2
2 5 1302.28 8 14.61 2209 258 0.43 / 606.43 2 2
3 7 2004.68 42 14.17 3008 1790 2.22 / 608.22 2 2
4 13 1606.84 20 14.28 2521 720 2.94 / 608.94 2 2
5 13 1031.52 20 14.47 1760 509 3.44 / 609.44 2 2
6 13 443.24 20 14.74 968 285 3.73 / 609.73 2 2
7 8 0.00 175 14.93 329 860 4.59 / 610.59 2 3
Average= 4.30
(KJ/cycle)

Cycle 140 GMT 3/ 8/2021 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 23 14.88 497 170 0.17 / 601.84 2 2
2 7 2005.52 42 14.18 3011 1793 1.96 / 603.63 2 2
3 13 1600.44 20 14.29 2503 715 2.68 / 604.35 2 2
4 13 1032.40 20 14.47 1757 508 3.19 / 604.86 2 2
5 13 451.20 20 14.74 976 288 3.47 / 605.15 2 2
6 8 0.08 175 14.93 327 854 4.33 / 606.00 2 2
Average= 4.30
(KJ/cycle)

Cycle 139 GMT 24/ 7/2021 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 23 14.88 493 169 0.17 / 597.47 2 2
2 7 2003.52 42 14.18 3005 1790 1.96 / 599.26 2 2
3 13 1594.28 20 14.30 2501 715 2.67 / 599.98 2 2
4 13 1015.72 20 14.49 1732 502 3.18 / 600.48 2 2
5 13 301.36 20 14.82 769 228 3.40 / 600.71 2 2
6 13 38.28 20 14.96 386 115 3.52 / 600.82 2 2
7 8 0.12 175 14.93 325 849 4.37 / 601.67 2 6
Average= 4.30
(KJ/cycle)

Cycle 138 GMT 14/ 7/2021 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 22 14.89 497 163 0.16 / 592.88 2 2
2 5 1303.00 8 14.62 2219 260 0.42 / 593.14 2 2
3 7 2003.32 42 14.17 3000 1785 2.21 / 594.92 2 2
4 13 1601.40 20 14.29 2501 715 2.92 / 595.64 2 2
5 13 1034.32 20 14.47 1765 511 3.43 / 596.15 2 2
6 13 457.24 20 14.73 987 291 3.72 / 596.44 2 2
7 8 0.36 175 14.93 330 862 4.59 / 597.30 2 2
Average= 4.30
(KJ/cycle)

Cycle 137 GMT 4/ 7/2021 5:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 22 14.88 490 160 0.16 / 588.61 2 2
2 7 2006.24 42 14.17 3013 1793 1.95 / 590.41 2 2
3 13 1591.04 20 14.30 2501 715 2.67 / 591.12 2 2
4 13 1018.52 20 14.48 1745 505 3.17 / 591.63 2 2
5 13 287.64 20 14.83 754 224 3.40 / 591.85 2 2
6 8 -0.08 175 14.94 331 865 4.26 / 592.72 2 3
Average= 4.30
(KJ/cycle)

Cycle 136 GMT 24/ 6/2021 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 23 14.88 493 169 0.17 / 584.02 2 2
2 3 971.28 -1 15.39 0 0 0.00 / 584.02 2 2
3 3 1021.04 1 15.07 1872 28 0.20 / 584.05 2 2
4 7 2004.32 43 14.17 3003 1830 2.03 / 585.88 2 2
5 13 1591.40 20 14.29 2497 714 2.74 / 586.59 2 2
6 13 1023.84 20 14.48 1753 508 3.25 / 587.10 2 2
7 13 312.40 20 14.81 788 233 3.48 / 587.33 2 2
8 13 33.96 20 14.96 389 116 3.60 / 587.45 2 2
9 8 -0.04 175 14.93 328 857 4.45 / 588.31 2 3
10 14 -0.04 30 14.91 331 148 4.60 / 588.45 2 4
Average= 4.30
(KJ/cycle)

Cycle 135 GMT 14/ 6/2021 5:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 22 14.90 489 160 0.16 / 579.35 2 2
2 5 1303.80 8 14.61 2218 259 0.42 / 579.61 2 2
3 7 2006.16 42 14.16 3004 1787 2.21 / 581.40 2 2
4 13 1605.48 20 14.28 2529 722 2.93 / 582.12 2 2
5 13 1041.76 20 14.47 1786 517 3.45 / 582.64 2 2
6 13 329.84 20 14.80 815 241 3.69 / 582.88 2 2
7 13 19.00 20 14.97 365 109 3.80 / 582.99 2 2
8 8 0.24 175 14.93 330 862 4.66 / 583.85 2 3
Average= 4.29
(KJ/cycle)

Cycle 134 GMT 4/ 6/2021 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 22 14.90 485 159 0.16 / 575.18 2 2
2 7 2002.16 42 14.18 3003 1788 1.95 / 576.97 2 2
3 13 1585.64 20 14.30 2490 712 2.66 / 577.68 2 2
4 13 897.48 20 14.54 1586 461 3.12 / 578.14 2 2
5 13 216.76 20 14.87 653 194 3.32 / 578.33 2 2
6 8 0.16 175 14.94 328 858 4.17 / 579.19 2 3
Average= 4.29
(KJ/cycle)

Cycle 133 GMT 25/ 5/2021 5: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 23 14.89 487 167 0.17 / 570.83 2 2
2 3 966.84 -1 15.39 0 0 0.00 / 570.83 2 2
3 7 2007.08 43 14.18 3011 1836 2.00 / 572.67 2 2
4 13 1585.16 20 14.30 2488 712 2.71 / 573.38 2 2
5 13 1007.72 20 14.49 1725 500 3.21 / 573.88 2 2
6 13 423.40 20 14.75 944 278 3.49 / 574.16 2 2
7 8 0.28 175 14.94 329 860 4.35 / 575.02 2 4
Average= 4.29
(KJ/cycle)

Cycle 132 GMT 15/ 5/2021 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 23 14.90 479 164 0.16 / 566.44 2 2
2 7 2005.52 42 14.18 3014 1795 1.96 / 568.23 2 2
3 13 1588.76 20 14.30 2489 712 2.67 / 568.94 2 2
4 13 1026.16 20 14.49 1747 506 3.18 / 569.45 2 2
5 13 331.64 20 14.80 818 242 3.42 / 569.69 2 2
6 13 18.68 20 14.97 365 109 3.53 / 569.80 2 2
7 8 -0.04 175 14.93 332 867 4.40 / 570.67 2 4
Average= 4.29
(KJ/cycle)

Cycle 131 GMT 5/ 5/2021 5: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 23 14.90 479 164 0.16 / 562.00 2 2
2 7 2002.36 42 14.19 3005 1791 1.96 / 563.79 2 2
3 13 1599.20 20 14.30 2506 717 2.67 / 564.51 2 2
4 13 1030.20 20 14.48 1753 508 3.18 / 565.01 2 2
5 13 453.04 20 14.74 985 290 3.47 / 565.30 2 2
6 13 19.76 20 14.98 365 109 3.58 / 565.41 2 2
7 8 0.40 175 14.94 328 858 4.44 / 566.27 2 3
Average= 4.29
(KJ/cycle)

Cycle 130 GMT 25/ 4/2021 5: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 22 14.91 489 160 0.16 / 557.70 2 2
2 3 1029.80 1 15.01 1878 28 0.19 / 557.73 2 2
3 7 2003.44 43 14.17 3000 1828 2.02 / 559.56 2 2
4 13 1472.88 20 14.34 2329 668 2.68 / 560.23 2 2
5 13 1052.32 20 14.46 1776 514 3.20 / 560.74 2 2
6 13 328.16 20 14.80 814 241 3.44 / 560.98 2 2
7 8 0.04 175 14.94 326 852 4.29 / 561.83 2 3
Average= 4.29
(KJ/cycle)

Cycle 129 GMT 15/ 4/2021 5: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 22 14.91 494 162 0.16 / 553.34 2 2
2 7 2002.44 42 14.19 2986 1780 1.94 / 555.12 2 2
3 13 1592.80 20 14.30 2504 716 2.66 / 555.83 2 2
4 13 1025.76 20 14.48 1744 505 3.16 / 556.34 2 2
5 13 311.20 20 14.82 785 233 3.40 / 556.57 2 2
6 13 35.28 20 14.97 385 115 3.51 / 556.69 2 2
7 8 0.24 175 14.94 327 855 4.37 / 557.54 2 4
Average= 4.29
(KJ/cycle)

Cycle 128 GMT 5/ 4/2021 4:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 23 14.91 469 161 0.16 / 548.92 2 2
2 7 2006.40 42 14.18 3003 1788 1.95 / 550.71 2 2
3 13 1590.20 20 14.31 2477 709 2.66 / 551.42 2 2
4 13 1019.88 20 14.49 1737 503 3.16 / 551.92 2 2
5 13 441.64 20 14.75 967 285 3.45 / 552.21 2 2
6 13 30.36 20 14.97 380 114 3.56 / 552.32 2 2
7 8 0.08 175 14.94 327 855 4.42 / 553.18 2 6
Average= 4.29
(KJ/cycle)

Cycle 127 GMT 26/ 3/2021 4:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 22 14.92 477 157 0.16 / 544.44 2 2
2 3 1046.44 1 14.94 1892 28 0.18 / 544.47 2 2
3 7 2005.40 42 14.18 3000 1787 1.97 / 546.26 2 2
4 13 1729.68 20 14.26 2665 760 2.73 / 547.02 2 2
5 13 1011.04 20 14.50 1732 502 3.23 / 547.52 2 2
6 13 434.56 20 14.76 958 283 3.52 / 547.80 2 2
7 13 28.08 20 14.98 375 112 3.63 / 547.92 2 2
8 8 0.00 175 14.94 323 844 4.47 / 548.76 2 5
Average= 4.29
(KJ/cycle)

Cycle 126 GMT 16/ 3/2021 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 23 14.91 484 166 0.17 / 540.15 2 2
2 3 922.16 -1 15.40 0 0 0.00 / 540.15 2 2
3 3 971.48 -1 15.42 0 0 0.00 / 540.15 2 2
4 7 2006.36 43 14.18 3012 1837 2.00 / 541.99 2 2
5 13 1597.12 20 14.30 2511 718 2.72 / 542.70 2 2
6 13 1018.80 20 14.49 1741 505 3.23 / 543.21 2 2
7 13 298.32 20 14.83 772 229 3.45 / 543.44 2 2
8 8 0.36 175 14.96 325 851 4.31 / 544.29 2 4
Average= 4.29
(KJ/cycle)

Cycle 125 GMT 6/ 3/2021 4: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 23 14.92 474 163 0.16 / 535.49 2 2
2 3 1020.20 1 15.06 1876 28 0.19 / 535.52 2 2
3 5 1302.56 8 14.62 2226 260 0.45 / 535.78 2 2
4 7 2005.80 42 14.17 3006 1789 2.24 / 537.57 2 2
5 13 1480.16 20 14.34 2338 671 2.91 / 538.24 2 2
6 13 1071.48 20 14.46 1822 527 3.44 / 538.77 2 2
7 13 349.96 20 14.80 840 249 3.69 / 539.02 2 2
8 13 45.20 20 14.96 403 121 3.81 / 539.14 2 2
9 8 0.00 175 14.94 324 847 4.65 / 539.98 2 3
Average= 4.29
(KJ/cycle)

Cycle 124 GMT 24/ 2/2021 3:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 22 14.91 484 159 0.16 / 531.04 2 2
2 3 1024.36 1 15.04 1874 28 0.19 / 531.06 2 2
3 7 2004.92 42 14.19 3011 1794 1.98 / 532.86 2 2
4 13 1595.60 20 14.31 2509 718 2.70 / 533.58 2 2
5 13 1024.48 20 14.49 1741 505 3.20 / 534.08 2 2
6 13 437.72 20 14.75 965 285 3.49 / 534.37 2 2
7 13 28.08 20 14.98 375 112 3.60 / 534.48 2 2
8 8 0.16 175 14.95 325 850 4.45 / 535.33 2 4
Average= 4.28
(KJ/cycle)

Cycle 123 GMT 14/ 2/2021 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 23 14.91 476 163 0.16 / 526.65 2 2
2 3 958.88 -1 15.40 0 0 0.00 / 526.65 2 2
3 7 2002.40 42 14.19 3005 1791 1.95 / 528.44 2 2
4 13 1596.40 20 14.31 2511 719 2.67 / 529.16 2 2
5 13 1031.16 20 14.49 1759 510 3.18 / 529.67 2 2
6 13 325.48 20 14.82 814 241 3.42 / 529.91 2 2
7 13 38.84 20 14.97 395 118 3.54 / 530.03 2 2
8 8 0.28 175 14.94 326 852 4.39 / 530.88 2 4
Average= 4.28
(KJ/cycle)

Cycle 122 GMT 4/ 2/2021 3:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 23 14.91 486 167 0.17 / 522.17 2 2
2 7 2005.12 42 14.19 3023 1802 1.97 / 523.97 2 2
3 13 1595.32 20 14.31 2504 717 2.68 / 524.69 2 2
4 13 1157.72 20 14.43 1927 556 3.24 / 525.24 2 2
5 13 412.80 20 14.77 935 276 3.52 / 525.52 2 2
6 13 24.84 20 14.98 370 111 3.63 / 525.63 2 2
7 8 0.04 175 14.95 326 853 4.48 / 526.48 2 3
Average= 4.28
(KJ/cycle)

Cycle 121 GMT 25/ 1/2021 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 23 14.91 476 163 0.16 / 517.82 2 2
2 7 2002.28 42 14.19 3007 1792 1.96 / 519.61 2 2
3 13 1467.00 20 14.35 2334 670 2.63 / 520.28 2 2
4 13 1048.20 20 14.48 1769 512 3.14 / 520.79 2 2
5 13 338.32 20 14.81 827 245 3.38 / 521.04 2 2
6 13 39.00 20 14.97 390 117 3.50 / 521.16 2 2
7 8 0.16 175 14.94 324 847 4.35 / 522.00 2 3
Average= 4.28
(KJ/cycle)

Cycle 120 GMT 15/ 1/2021 3:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 22 14.92 489 161 0.16 / 513.32 2 2
2 7 2002.72 42 14.19 3007 1792 1.95 / 515.11 2 2
3 13 1727.12 20 14.28 2667 762 2.71 / 515.87 2 2
4 13 1125.72 20 14.46 1880 544 3.26 / 516.42 2 2
5 13 386.32 20 14.79 891 264 3.52 / 516.68 2 2
6 13 49.20 20 14.97 408 122 3.64 / 516.80 2 2
7 8 0.04 175 14.95 326 853 4.50 / 517.66 2 3
Average= 4.28
(KJ/cycle)

Cycle 119 GMT 5/ 1/2021 3:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 22 14.91 491 161 0.16 / 509.05 2 2
2 7 2006.68 42 14.19 3013 1796 1.96 / 510.85 2 2
3 13 1599.00 20 14.31 2521 722 2.68 / 511.57 2 2
4 13 1031.88 20 14.50 1759 510 3.19 / 512.08 2 2
5 13 326.84 20 14.82 808 239 3.43 / 512.32 2 2
6 8 0.24 175 14.96 320 838 4.27 / 513.16 2 2
Average= 4.28
(KJ/cycle)

Cycle 118 GMT 26/12/2020 3:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 23 14.91 492 169 0.17 / 504.63 2 2
2 7 2005.00 42 14.18 3005 1790 1.96 / 506.42 2 2
3 13 1592.48 20 14.32 2498 715 2.67 / 507.14 2 2
4 13 1017.16 20 14.50 1738 504 3.18 / 507.64 2 2
5 13 439.08 20 14.76 962 284 3.46 / 507.93 2 2
6 13 29.24 20 14.98 380 114 3.58 / 508.04 2 2
7 8 0.08 175 14.95 326 853 4.43 / 508.89 2 2
Average= 4.28
(KJ/cycle)

Cycle 117 GMT 16/12/2020 3:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 23 14.91 495 170 0.17 / 500.04 2 2
2 5 1306.32 8 14.62 2217 259 0.43 / 500.30 2 2
3 7 2002.16 42 14.18 3009 1792 2.22 / 502.09 2 2
4 13 1586.16 20 14.32 2497 715 2.94 / 502.81 2 2
5 13 1021.80 20 14.49 1753 508 3.44 / 503.32 2 2
6 13 445.28 20 14.76 975 288 3.73 / 503.60 2 2
7 8 0.20 175 14.95 329 861 4.59 / 504.47 2 2
Average= 4.28
(KJ/cycle)

Cycle 116 GMT 6/12/2020 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 23 14.90 502 172 0.17 / 495.72 2 2
2 7 2003.92 42 14.19 3007 1792 1.96 / 497.51 2 2
3 13 1731.24 20 14.27 2681 765 2.73 / 498.28 2 2
4 13 1006.56 20 14.50 1734 503 3.23 / 498.78 2 2
5 13 300.28 20 14.84 778 231 3.46 / 499.01 2 2
6 8 -0.04 175 14.96 329 861 4.32 / 499.87 2 2
Average= 4.27
(KJ/cycle)

Cycle 115 GMT 26/11/2020 3:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 23 14.91 485 166 0.17 / 491.43 2 2
2 7 2002.32 42 14.19 3024 1802 1.97 / 493.24 2 2
3 13 1594.52 20 14.32 2505 717 2.69 / 493.95 2 2
4 13 1026.84 20 14.49 1756 509 3.19 / 494.46 2 2
5 13 312.24 20 14.83 782 232 3.43 / 494.69 2 2
6 8 -0.04 175 14.96 326 853 4.28 / 495.55 2 3
Average= 4.27
(KJ/cycle)

Cycle 114 GMT 16/11/2020 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 23 14.89 495 170 0.17 / 487.01 2 2
2 7 2005.84 42 14.20 3013 1797 1.97 / 488.81 2 2
3 13 1728.64 20 14.28 2680 765 2.73 / 489.57 2 2
4 13 1150.00 20 14.45 1915 553 3.29 / 490.13 2 2
5 13 423.48 20 14.78 950 281 3.57 / 490.41 2 2
6 8 0.28 175 14.96 329 861 4.43 / 491.27 2 2
Average= 4.27
(KJ/cycle)

Cycle 113 GMT 6/11/2020 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 22 14.91 492 161 0.16 / 482.73 2 2
2 7 2003.92 43 14.19 3010 1837 2.00 / 484.56 2 2
3 13 1461.64 20 14.37 2330 670 2.67 / 485.23 2 2
4 13 1046.00 20 14.48 1771 513 3.18 / 485.74 2 2
5 13 323.08 20 14.83 801 238 3.42 / 485.98 2 2
6 8 0.16 175 14.95 328 858 4.28 / 486.84 2 2
Average= 4.27
(KJ/cycle)

Cycle 112 GMT 27/10/2020 3:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 22 14.90 504 165 0.17 / 478.31 2 2
2 7 2003.24 42 14.20 3013 1797 1.96 / 480.11 2 2
3 13 1726.52 20 14.29 2672 764 2.73 / 480.87 2 2
4 13 996.16 20 14.52 1710 497 3.22 / 481.37 2 2
5 13 564.48 20 14.70 1140 335 3.56 / 481.70 2 2
6 8 1.20 175 14.96 329 861 4.42 / 482.56 2 4
Average= 4.27
(KJ/cycle)

Cycle 111 GMT 17/10/2020 3:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 22 14.90 496 163 0.16 / 473.93 2 2
2 7 2006.16 42 14.20 3019 1801 1.96 / 475.73 2 2
3 13 1598.44 20 14.32 2523 723 2.69 / 476.45 2 2
4 13 1157.88 20 14.45 1921 555 3.24 / 477.01 2 2
5 13 420.32 20 14.78 940 278 3.52 / 477.28 2 2
6 8 -0.08 175 14.96 329 861 4.38 / 478.14 2 8
Average= 4.27
(KJ/cycle)

Cycle 110 GMT 7/10/2020 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 23 14.91 482 165 0.17 / 469.57 2 2
2 7 2002.64 42 14.19 3008 1793 1.96 / 471.37 2 2
3 13 1458.40 20 14.37 2332 670 2.63 / 472.04 2 2
4 13 1038.76 20 14.50 1759 510 3.14 / 472.55 2 2
5 13 328.04 20 14.83 809 240 3.38 / 472.79 2 2
6 13 36.96 20 14.98 394 118 3.50 / 472.90 2 2
7 8 0.24 175 14.95 329 861 4.36 / 473.76 2 3
Average= 4.27
(KJ/cycle)

Cycle 109 GMT 27/ 9/2020 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 22 14.91 494 162 0.16 / 465.31 2 2
2 7 2003.72 42 14.20 3016 1799 1.96 / 467.11 2 2
3 13 1591.80 20 14.33 2499 716 2.68 / 467.83 2 2
4 13 1011.60 20 14.51 1722 500 3.18 / 468.33 2 2
5 13 294.80 20 14.85 760 226 3.40 / 468.55 2 2
6 8 0.12 175 14.96 327 856 4.26 / 469.41 2 3
Average= 4.27
(KJ/cycle)

Cycle 108 GMT 17/ 9/2020 3:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 22 14.91 484 159 0.16 / 461.03 2 2
2 7 2003.44 42 14.20 3012 1796 1.96 / 462.83 2 2
3 13 1594.84 20 14.33 2504 718 2.67 / 463.55 2 2
4 13 1033.12 20 14.50 1759 510 3.18 / 464.06 2 2
5 13 322.92 20 14.84 798 237 3.42 / 464.29 2 2
6 8 0.36 175 14.96 327 856 4.28 / 465.15 2 2
Average= 4.27
(KJ/cycle)

Cycle 107 GMT 7/ 9/2020 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 22 14.92 485 159 0.16 / 456.72 2 2
2 7 2001.36 42 14.21 3005 1793 1.95 / 458.51 2 2
3 13 1592.04 20 14.34 2492 715 2.67 / 459.23 2 2
4 13 1028.40 20 14.51 1747 507 3.17 / 459.74 2 2
5 13 442.16 20 14.77 964 285 3.46 / 460.02 2 2
6 8 -0.24 175 14.96 326 853 4.31 / 460.87 2 3
Average= 4.27
(KJ/cycle)

Cycle 106 GMT 28/ 8/2020 3: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 22 14.91 492 161 0.16 / 452.40 2 2
2 7 2003.32 42 14.20 3016 1799 1.96 / 454.20 2 2
3 13 1589.80 20 14.33 2500 716 2.68 / 454.91 2 2
4 13 1023.12 20 14.51 1746 507 3.18 / 455.42 2 2
5 13 433.00 20 14.78 950 281 3.46 / 455.70 2 2
6 8 0.20 175 14.96 329 861 4.33 / 456.56 2 2
Average= 4.27
(KJ/cycle)

Cycle 105 GMT 18/ 8/2020 2:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 22 14.91 490 161 0.16 / 448.03 2 2
2 7 2004.08 42 14.20 3008 1794 1.95 / 449.82 2 2
3 13 1597.40 20 14.33 2499 716 2.67 / 450.54 2 2
4 13 1165.72 20 14.45 1929 557 3.23 / 451.10 2 2
5 13 425.20 20 14.78 943 279 3.51 / 451.37 2 2
6 8 0.32 175 14.96 329 861 4.37 / 452.24 2 3
Average= 4.27
(KJ/cycle)

Cycle 104 GMT 8/ 8/2020 2:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 22 14.91 492 161 0.16 / 443.78 2 2
2 7 2005.00 42 14.20 3027 1805 1.97 / 445.58 2 2
3 13 1606.72 20 14.33 2504 718 2.68 / 446.30 2 2
4 13 1044.60 20 14.50 1771 514 3.20 / 446.81 2 2
5 13 202.44 20 14.91 629 188 3.39 / 447.00 2 2
6 8 0.28 175 14.97 331 867 4.25 / 447.87 2 3
Average= 4.27
(KJ/cycle)

Cycle 103 GMT 29/ 7/2020 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 22 14.92 489 161 0.16 / 439.42 2 2
2 7 2003.56 42 14.21 3010 1796 1.96 / 441.21 2 2
3 13 1729.60 20 14.30 2670 764 2.72 / 441.98 2 2
4 13 1007.16 20 14.53 1724 501 3.22 / 442.48 2 2
5 13 427.28 20 14.78 948 280 3.50 / 442.76 2 2
6 8 -0.16 175 14.97 327 857 4.36 / 443.61 2 2
Average= 4.27
(KJ/cycle)

Cycle 102 GMT 19/ 7/2020 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 22 14.91 492 161 0.16 / 435.14 2 2
2 7 2003.80 42 14.21 3003 1792 1.95 / 436.93 2 2
3 13 1595.28 20 14.34 2505 718 2.67 / 437.65 2 2
4 13 1023.60 20 14.52 1744 506 3.18 / 438.16 2 2
5 13 322.48 20 14.84 798 237 3.42 / 438.39 2 2
6 8 0.24 175 14.97 329 862 4.28 / 439.26 2 5
Average= 4.26
(KJ/cycle)

Cycle 101 GMT 9/ 7/2020 2:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 22 14.92 486 160 0.16 / 430.78 2 2
2 7 2003.84 43 14.20 3003 1834 1.99 / 432.61 2 2
3 13 1593.56 20 14.34 2505 718 2.71 / 433.33 2 2
4 13 1022.36 20 14.52 1739 505 3.22 / 433.84 2 2
5 13 447.32 20 14.77 970 287 3.50 / 434.12 2 2
6 8 0.24 175 14.97 327 857 4.36 / 434.98 2 3
Average= 4.26
(KJ/cycle)

Cycle 100 GMT 29/ 6/2020 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 22 14.93 484 159 0.16 / 426.46 2 2
2 7 2004.84 42 14.21 3016 1800 1.96 / 428.26 2 2
3 13 1593.56 20 14.34 2497 716 2.68 / 428.97 2 2
4 13 1023.00 20 14.52 1744 506 3.18 / 429.48 2 2
5 13 442.04 20 14.78 966 286 3.47 / 429.76 2 2
6 8 0.28 175 14.97 326 854 4.32 / 430.62 2 4
Average= 4.26
(KJ/cycle)

Cycle 99 GMT 19/ 6/2020 1:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 22 14.92 496 163 0.16 / 422.11 2 2
2 3 1028.92 1 15.04 1870 28 0.19 / 422.14 2 2
3 7 2004.68 42 14.21 3001 1791 1.98 / 423.93 2 2
4 13 1601.84 20 14.34 2505 718 2.70 / 424.65 2 2
5 13 1024.84 20 14.51 1748 507 3.21 / 425.16 2 2
6 13 435.92 20 14.78 957 283 3.49 / 425.44 2 2
7 8 -0.12 175 14.97 327 857 4.35 / 426.30 2 3
Average= 4.26
(KJ/cycle)

Cycle 98 GMT 9/ 6/2020 1:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 22 14.92 489 161 0.16 / 417.59 2 2
2 7 2006.36 42 14.21 2997 1789 1.95 / 419.38 2 2
3 13 1591.56 20 14.34 2499 717 2.67 / 420.09 2 2
4 13 1026.48 20 14.52 1751 508 3.17 / 420.60 2 2
5 13 310.44 20 14.85 783 233 3.41 / 420.83 2 2
6 13 37.80 20 15.00 389 117 3.52 / 420.95 2 2
7 8 -0.04 175 14.97 325 851 4.38 / 421.80 2 5
8 14 -0.04 30 14.94 330 148 4.52 / 421.95 2 4
Average= 4.26
(KJ/cycle)

Cycle 97 GMT 30/ 5/2020 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 21 14.92 489 153 0.15 / 413.21 2 2
2 3 1022.64 1 15.06 1871 28 0.18 / 413.24 2 2
3 7 2001.92 42 14.21 2994 1787 1.97 / 415.03 2 2
4 13 1726.88 20 14.30 2669 763 2.73 / 415.79 2 2
5 13 1012.04 20 14.53 1722 500 3.23 / 416.29 2 2
6 13 439.96 20 14.79 963 285 3.52 / 416.58 2 2
7 8 0.32 175 14.97 325 851 4.37 / 417.43 2 2
Average= 4.26
(KJ/cycle)

Cycle 96 GMT 20/ 5/2020 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 22 14.94 485 159 0.16 / 408.84 2 2
2 3 964.88 -1 15.42 0 0 0.00 / 408.84 2 2
3 7 2001.56 42 14.21 3000 1790 1.95 / 410.63 2 2
4 13 1590.12 20 14.35 2494 716 2.67 / 411.35 2 2
5 13 1018.28 20 14.52 1733 503 3.17 / 411.85 2 2
6 13 310.12 20 14.85 782 232 3.40 / 412.08 2 2
7 13 33.24 20 15.00 384 115 3.52 / 412.20 2 2
8 8 0.08 175 14.97 328 859 4.38 / 413.06 2 3
Average= 4.26
(KJ/cycle)

Cycle 95 GMT 10/ 5/2020 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 21 14.95 476 149 0.15 / 404.37 2 2
2 3 1046.36 1 14.96 1888 28 0.18 / 404.40 2 2
3 7 2003.44 42 14.22 2989 1785 1.96 / 406.18 2 2
4 13 1730.44 20 14.30 2680 766 2.73 / 406.95 2 2
5 13 1013.04 20 14.53 1737 505 3.23 / 407.45 2 2
6 13 308.44 20 14.86 782 232 3.47 / 407.69 2 2
7 8 0.28 175 14.98 324 849 4.32 / 408.54 2 2
8 14 0.28 30 14.96 329 148 4.46 / 408.68 2 3
Average= 4.26
(KJ/cycle)

Cycle 94 GMT 30/ 4/2020 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 22 14.95 478 157 0.16 / 400.10 2 2
2 3 973.60 -1 15.45 0 0 0.00 / 400.10 2 2
3 7 2004.76 43 14.21 2986 1825 1.98 / 401.93 2 2
4 13 1595.16 20 14.35 2500 717 2.70 / 402.64 2 2
5 13 1018.44 20 14.53 1736 504 3.20 / 403.15 2 2
6 13 300.08 20 14.86 767 228 3.43 / 403.38 2 2
7 8 0.04 175 14.98 322 844 4.28 / 404.22 2 2
Average= 4.25
(KJ/cycle)

Cycle 93 GMT 19/ 4/2020 23:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 21 14.94 482 151 0.15 / 395.81 2 2
2 3 1026.72 1 15.05 1865 28 0.18 / 395.84 2 2
3 7 2005.80 42 14.21 3004 1793 1.97 / 397.63 2 2
4 13 1595.64 20 14.35 2498 717 2.69 / 398.35 2 2
5 13 1033.08 20 14.52 1759 511 3.20 / 398.86 2 2
6 13 311.20 20 14.86 787 234 3.43 / 399.09 2 2
7 8 0.36 175 14.99 325 853 4.29 / 399.94 2 2
Average= 4.25
(KJ/cycle)

Cycle 92 GMT 9/ 4/2020 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 22 14.95 478 157 0.16 / 391.44 2 2
2 3 963.96 -1 15.42 0 0 0.00 / 391.44 2 2
3 7 2003.64 42 14.22 2991 1786 1.94 / 393.23 2 2
4 13 1594.00 20 14.35 2506 719 2.66 / 393.95 2 2
5 13 1021.96 20 14.53 1738 505 3.17 / 394.45 2 2
6 13 315.12 20 14.85 791 235 3.40 / 394.69 2 2
7 13 40.88 20 15.00 392 118 3.52 / 394.81 2 2
8 8 0.12 175 14.97 325 851 4.37 / 395.66 2 2
Average= 4.25
(KJ/cycle)

Cycle 91 GMT 30/ 3/2020 22:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 21 14.95 474 149 0.15 / 387.06 2 2
2 3 1065.88 2 14.91 1900 57 0.21 / 387.12 2 2
3 7 2006.36 43 14.21 2986 1825 2.03 / 388.94 2 2
4 13 1583.20 20 14.35 2481 712 2.74 / 389.66 2 2
5 13 1003.80 20 14.54 1716 499 3.24 / 390.16 2 2
6 13 418.56 20 14.80 941 279 3.52 / 390.43 2 2
7 8 0.48 175 14.98 325 852 4.37 / 391.29 2 4
Average= 4.25
(KJ/cycle)

Cycle 90 GMT 20/ 3/2020 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 22 14.95 470 155 0.15 / 382.71 2 2
2 3 964.72 -1 15.42 0 0 0.00 / 382.71 2 2
3 7 2001.92 42 14.21 2983 1780 1.93 / 384.49 2 2
4 13 1592.80 20 14.36 2488 715 2.65 / 385.21 2 2
5 13 1021.20 20 14.53 1733 504 3.15 / 385.71 2 2
6 13 310.56 20 14.86 781 232 3.39 / 385.94 2 2
7 13 34.48 20 15.00 384 115 3.50 / 386.06 2 2
8 8 0.00 175 14.98 326 855 4.35 / 386.91 2 5
Average= 4.25
(KJ/cycle)

Cycle 89 GMT 10/ 3/2020 22: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 22 14.96 478 157 0.16 / 378.35 2 2
2 7 2001.52 42 14.22 2981 1780 1.94 / 380.13 2 2
3 13 1602.16 20 14.35 2503 718 2.66 / 380.85 2 2
4 13 1037.84 20 14.53 1756 510 3.17 / 381.36 2 2
5 13 319.96 20 14.86 791 235 3.40 / 381.60 2 2
6 13 35.80 20 15.01 382 115 3.52 / 381.71 2 2
7 8 0.08 175 14.98 323 847 4.36 / 382.56 2 3
Average= 4.25
(KJ/cycle)

Cycle 88 GMT 29/ 2/2020 21:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 22 14.94 482 158 0.16 / 374.16 2 2
2 7 2002.76 42 14.22 2979 1779 1.94 / 375.94 2 2
3 13 1584.88 20 14.36 2491 715 2.65 / 376.65 2 2
4 13 900.08 20 14.59 1577 460 3.11 / 377.11 2 2
5 13 326.96 20 14.85 801 238 3.35 / 377.35 2 2
6 8 0.08 175 14.99 323 847 4.20 / 378.20 2 3
Average= 4.25
(KJ/cycle)

Cycle 87 GMT 19/ 2/2020 21:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 22 14.94 482 158 0.16 / 369.74 2 2
2 7 2003.28 42 14.21 2997 1789 1.95 / 371.52 2 2
3 13 1597.24 20 14.36 2491 715 2.66 / 372.24 2 2
4 13 1024.20 20 14.53 1736 504 3.17 / 372.74 2 2
5 13 446.40 20 14.79 968 286 3.45 / 373.03 2 2
6 13 29.40 20 15.01 376 113 3.57 / 373.14 2 2
7 8 0.20 175 14.98 326 855 4.42 / 374.00 2 7
Average= 4.25
(KJ/cycle)

Cycle 86 GMT 9/ 2/2020 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 22 14.94 478 157 0.16 / 365.36 2 2
2 7 2004.00 42 14.22 2991 1786 1.94 / 367.14 2 2
3 13 1598.28 20 14.36 2494 716 2.66 / 367.86 2 2
4 13 1033.68 20 14.53 1751 509 3.17 / 368.37 2 2
5 13 312.60 20 14.86 786 234 3.40 / 368.60 2 2
6 13 35.92 20 15.00 389 117 3.52 / 368.72 2 2
7 8 0.08 175 14.98 327 857 4.38 / 369.58 2 4
Average= 4.25
(KJ/cycle)

Cycle 85 GMT 30/ 1/2020 20:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 21 14.94 477 150 0.15 / 360.93 2 2
2 3 1023.24 1 15.06 1873 28 0.18 / 360.96 2 2
3 7 2003.04 42 14.22 2999 1791 1.97 / 362.75 2 2
4 13 1730.24 20 14.31 2690 770 2.74 / 363.52 2 2
5 13 1002.72 20 14.55 1708 497 3.24 / 364.02 2 2
6 13 293.40 20 14.87 758 225 3.46 / 364.25 2 2
7 13 15.56 20 15.02 354 106 3.57 / 364.35 2 2
8 8 0.08 175 14.98 324 849 4.42 / 365.20 2 2
Average= 4.25
(KJ/cycle)

Cycle 84 GMT 20/ 1/2020 20:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 22 14.94 490 161 0.16 / 356.55 2 2
2 7 2013.24 42 14.21 3014 1799 1.96 / 358.35 2 2
3 13 1606.68 20 14.35 2509 720 2.68 / 359.07 2 2
4 13 1033.36 20 14.53 1760 511 3.19 / 359.58 2 2
5 13 326.48 20 14.86 806 240 3.43 / 359.82 2 2
6 13 37.40 20 15.00 389 117 3.55 / 359.94 2 2
7 8 0.08 175 14.98 324 849 4.40 / 360.78 2 5
Average= 4.24
(KJ/cycle)

Cycle 83 GMT 10/ 1/2020 20:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 21 14.94 485 152 0.15 / 352.22 2 2
2 3 1039.52 1 15.00 1891 28 0.18 / 352.25 2 2
3 7 2004.56 42 14.22 2989 1785 1.97 / 354.03 2 2
4 13 1595.28 20 14.36 2498 717 2.68 / 354.75 2 2
5 13 1022.00 20 14.54 1745 507 3.19 / 355.26 2 2
6 13 438.32 20 14.80 958 284 3.47 / 355.54 2 2
7 8 0.24 175 14.99 323 847 4.32 / 356.39 2 2
Average= 4.24
(KJ/cycle)

Cycle 82 GMT 31/12/2019 19:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 22 14.93 482 158 0.16 / 347.89 2 2
2 3 952.08 -1 15.42 0 0 0.00 / 347.89 2 2
3 7 2005.96 42 14.22 2985 1783 1.94 / 349.67 2 2
4 13 1726.20 20 14.32 2660 762 2.70 / 350.43 2 2
5 13 1004.80 20 14.55 1706 496 3.20 / 350.93 2 2
6 13 424.20 20 14.80 942 279 3.48 / 351.21 2 2
7 8 0.12 175 14.99 328 860 4.34 / 352.07 2 3
Average= 4.24
(KJ/cycle)

Cycle 81 GMT 21/12/2019 19:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 21 14.93 491 154 0.15 / 343.29 2 2
2 3 1019.56 1 15.09 1875 28 0.18 / 343.32 2 2
3 7 2007.08 43 14.21 3005 1836 2.02 / 345.16 2 2
4 13 1607.08 20 14.35 2519 723 2.74 / 345.88 2 2
5 13 1024.56 20 14.54 1732 504 3.25 / 346.38 2 2
6 13 308.96 20 14.86 778 231 3.48 / 346.61 2 2
7 13 16.76 20 15.02 362 109 3.58 / 346.72 2 2
8 8 0.00 175 14.98 327 857 4.44 / 347.58 2 3
9 14 0.00 30 14.96 329 148 4.59 / 347.73 2 4
Average= 4.24
(KJ/cycle)

Cycle 80 GMT 11/12/2019 19:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 21 14.94 484 152 0.15 / 338.89 2 2
2 7 2006.04 42 14.21 3005 1793 1.95 / 340.68 2 2
3 13 1587.12 20 14.36 2487 714 2.66 / 341.40 2 2
4 13 900.24 20 14.59 1575 460 3.12 / 341.86 2 2
5 13 469.72 20 14.77 1003 296 3.42 / 342.15 2 2
6 13 33.00 20 15.00 387 116 3.53 / 342.27 2 2
7 8 0.20 175 14.97 332 870 4.40 / 343.14 2 3
Average= 4.24
(KJ/cycle)

Cycle 79 GMT 1/12/2019 18:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 22 14.94 487 160 0.16 / 334.63 2 2
2 7 2001.52 42 14.22 2999 1791 1.95 / 336.42 2 2
3 13 1593.08 20 14.36 2491 715 2.67 / 337.13 2 2
4 13 1029.84 20 14.54 1745 507 3.17 / 337.64 2 2
5 13 303.80 20 14.87 775 230 3.40 / 337.87 2 2
6 8 0.08 175 14.98 330 865 4.27 / 338.74 2 2
Average= 4.23
(KJ/cycle)

Cycle 78 GMT 21/11/2019 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 21 14.93 495 155 0.16 / 330.36 2 2
2 7 2006.00 42 14.22 3010 1798 1.95 / 332.16 2 2
3 13 1477.48 20 14.40 2352 677 2.63 / 332.84 2 2
4 13 1059.20 20 14.52 1794 521 3.15 / 333.36 2 2
5 13 332.04 20 14.85 816 242 3.39 / 333.60 2 2
6 8 0.20 175 14.98 331 868 4.26 / 334.47 2 13
Average= 4.23
(KJ/cycle)

Cycle 77 GMT 11/11/2019 18:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 21 14.93 492 154 0.15 / 326.06 2 2
2 7 2003.08 42 14.23 2983 1783 1.94 / 327.84 2 2
3 13 1597.44 20 14.36 2497 717 2.65 / 328.56 2 2
4 13 1027.40 20 14.54 1736 505 3.16 / 329.06 2 2
5 13 446.84 20 14.79 971 287 3.45 / 329.35 2 2
6 8 0.04 175 14.98 326 855 4.30 / 330.21 2 3
Average= 4.23
(KJ/cycle)

Cycle 76 GMT 1/11/2019 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 21 14.93 494 155 0.15 / 321.73 2 2
2 7 2004.60 42 14.23 2984 1783 1.94 / 323.51 2 2
3 13 1735.52 20 14.32 2664 763 2.70 / 324.27 2 2
4 13 1004.40 20 14.55 1706 496 3.20 / 324.77 2 2
5 13 421.76 20 14.81 932 276 3.47 / 325.05 2 2
6 8 0.24 175 14.99 327 858 4.33 / 325.90 2 5
Average= 4.23
(KJ/cycle)

Cycle 75 GMT 22/10/2019 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 21 14.93 500 157 0.16 / 317.43 2 2
2 7 2003.00 42 14.23 2981 1782 1.94 / 319.21 2 2
3 13 1587.16 20 14.37 2493 716 2.65 / 319.93 2 2
4 13 1011.80 20 14.55 1723 501 3.16 / 320.43 2 2
5 13 430.04 20 14.81 944 280 3.44 / 320.71 2 2
6 8 -0.08 175 14.99 330 866 4.30 / 321.57 2 2
Average= 4.23
(KJ/cycle)

Cycle 74 GMT 12/10/2019 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 21 14.93 495 155 0.16 / 313.12 2 2
2 7 2001.88 42 14.23 2985 1784 1.94 / 314.91 2 2
3 13 1583.60 20 14.38 2487 715 2.65 / 315.62 2 2
4 13 1016.72 20 14.55 1729 503 3.16 / 316.13 2 2
5 13 432.52 20 14.81 949 281 3.44 / 316.41 2 2
6 8 0.16 175 14.99 329 863 4.30 / 317.27 2 3
Average= 4.23
(KJ/cycle)

Cycle 73 GMT 2/10/2019 17: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 22 14.93 503 165 0.17 / 308.83 2 2
2 7 2003.24 43 14.23 2994 1832 2.00 / 310.66 2 2
3 13 1593.24 20 14.38 2484 714 2.71 / 311.37 2 2
4 13 1016.08 20 14.55 1723 501 3.21 / 311.87 2 2
5 13 300.08 20 14.88 761 226 3.44 / 312.10 2 2
6 8 0.36 175 14.99 331 868 4.31 / 312.97 2 2
Average= 4.23
(KJ/cycle)

Cycle 72 GMT 22/ 9/2019 16:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 21 14.94 499 157 0.16 / 304.55 2 2
2 7 2003.92 42 14.23 2996 1791 1.95 / 306.34 2 2
3 13 1594.36 20 14.38 2502 720 2.67 / 307.06 2 2
4 13 1019.32 20 14.55 1737 505 3.17 / 307.57 2 2
5 13 305.68 20 14.88 774 230 3.40 / 307.80 2 2
6 8 -0.04 175 14.99 330 866 4.27 / 308.66 2 3
Average= 4.23
(KJ/cycle)

Cycle 71 GMT 12/ 9/2019 16:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 21 14.94 492 154 0.15 / 300.25 2 2
2 7 2005.28 42 14.24 2988 1787 1.94 / 302.04 2 2
3 13 1726.44 20 14.34 2658 762 2.70 / 302.80 2 2
4 13 994.92 20 14.57 1705 497 3.20 / 303.30 2 2
5 13 285.12 20 14.89 752 224 3.42 / 303.52 2 2
6 8 -0.12 175 15.00 332 871 4.30 / 304.39 2 2
Average= 4.23
(KJ/cycle)

Cycle 70 GMT 2/ 9/2019 16: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 21 14.95 486 153 0.15 / 295.92 2 2
2 7 2005.64 42 14.24 3004 1797 1.95 / 297.72 2 2
3 13 1594.12 20 14.39 2478 713 2.66 / 298.43 2 2
4 13 1020.00 20 14.56 1735 505 3.17 / 298.94 2 2
5 13 435.48 20 14.82 958 284 3.45 / 299.22 2 2
6 8 0.60 175 15.00 334 877 4.33 / 300.10 2 5
Average= 4.23
(KJ/cycle)

Cycle 69 GMT 23/ 8/2019 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 21 14.96 486 153 0.15 / 291.40 2 2
2 7 2004.08 42 14.24 2977 1780 1.93 / 293.18 2 2
3 13 1590.12 20 14.39 2490 717 2.65 / 293.90 2 2
4 13 1009.56 20 14.57 1720 501 3.15 / 294.40 2 2
5 13 289.04 20 14.90 748 223 3.37 / 294.63 2 2
6 13 64.28 20 15.01 427 128 3.50 / 294.75 2 2
7 8 -0.08 175 14.99 330 866 4.37 / 295.62 2 5
8 14 -0.08 30 14.97 334 150 4.52 / 295.77 2 2
Average= 4.23
(KJ/cycle)

Cycle 68 GMT 13/ 8/2019 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 21 14.96 482 151 0.15 / 287.11 2 2
2 7 2005.88 42 14.25 2981 1784 1.94 / 288.90 2 2
3 13 1732.68 20 14.35 2665 765 2.70 / 289.66 2 2
4 13 1018.88 20 14.57 1729 504 3.20 / 290.17 2 2
5 13 312.28 20 14.90 772 230 3.43 / 290.40 2 2
6 8 0.12 175 15.01 326 856 4.29 / 291.25 2 2
Average= 4.22
(KJ/cycle)

Cycle 67 GMT 3/ 8/2019 15: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 21 14.96 498 156 0.16 / 282.83 2 2
2 3 1027.20 1 15.07 1884 28 0.18 / 282.86 2 2
3 7 2005.08 42 14.25 2991 1790 1.97 / 284.65 2 2
4 13 1593.44 20 14.40 2491 717 2.69 / 285.36 2 2
5 13 1027.76 20 14.57 1739 507 3.20 / 285.87 2 2
6 13 318.68 20 14.89 788 235 3.43 / 286.10 2 2
7 8 0.16 175 15.01 326 856 4.29 / 286.96 2 4
Average= 4.22
(KJ/cycle)

Cycle 66 GMT 24/ 7/2019 14:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 21 14.97 481 151 0.15 / 278.55 2 2
2 7 2003.20 43 14.25 2985 1829 1.98 / 280.37 2 2
3 13 1585.68 20 14.40 2497 719 2.70 / 281.09 2 2
4 13 998.00 20 14.59 1708 498 3.20 / 281.59 2 2
5 13 267.68 20 14.93 715 213 3.41 / 281.81 2 2
6 8 0.12 175 15.02 329 865 4.28 / 282.67 2 2
Average= 4.22
(KJ/cycle)

Cycle 65 GMT 14/ 7/2019 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 21 14.98 487 153 0.15 / 274.17 2 2
2 7 2002.12 42 14.25 2989 1789 1.94 / 275.96 2 2
3 13 1605.32 20 14.40 2515 724 2.67 / 276.68 2 2
4 13 1025.44 20 14.58 1744 509 3.17 / 277.19 2 2
5 13 316.24 20 14.90 786 234 3.41 / 277.43 2 2
6 13 19.08 20 15.06 356 107 3.52 / 277.53 2 2
7 8 0.00 175 15.01 328 862 4.38 / 278.39 2 6
Average= 4.22
(KJ/cycle)

Cycle 64 GMT 4/ 7/2019 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 21 14.99 483 152 0.15 / 269.90 2 2
2 7 2002.00 42 14.26 2994 1793 1.95 / 271.69 2 2
3 13 1590.40 20 14.41 2509 723 2.67 / 272.41 2 2
4 13 1018.56 20 14.59 1735 506 3.17 / 272.92 2 2
5 13 310.16 20 14.91 782 233 3.41 / 273.15 2 2
6 8 0.08 175 15.03 328 863 4.27 / 274.02 2 3
Average= 4.22
(KJ/cycle)

Cycle 63 GMT 24/ 6/2019 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 22 14.99 484 160 0.16 / 265.59 2 2
2 3 945.08 -1 15.45 0 0 0.00 / 265.59 2 2
3 7 2002.12 42 14.26 2980 1785 1.94 / 267.38 2 2
4 13 1582.72 20 14.42 2488 718 2.66 / 268.10 2 2
5 13 1015.44 20 14.59 1726 504 3.17 / 268.60 2 2
6 13 432.56 20 14.85 952 283 3.45 / 268.88 2 2
7 8 0.04 175 15.03 328 863 4.31 / 269.75 2 3
Average= 4.21
(KJ/cycle)

Cycle 62 GMT 14/ 6/2019 13: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 21 14.99 479 151 0.15 / 261.20 2 2
2 3 1061.80 2 14.96 1905 57 0.21 / 261.25 2 2
3 7 2002.36 42 14.25 2985 1787 1.99 / 263.04 2 2
4 13 1721.60 20 14.37 2670 767 2.76 / 263.81 2 2
5 13 989.64 20 14.60 1697 496 3.26 / 264.30 2 2
6 13 407.36 20 14.87 914 272 3.53 / 264.57 2 2
7 8 0.56 175 15.03 327 860 4.39 / 265.44 2 3
Average= 4.21
(KJ/cycle)

Cycle 61 GMT 4/ 6/2019 12:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 21 15.00 479 151 0.15 / 256.86 2 2
2 7 2004.84 42 14.25 3007 1800 1.95 / 258.66 2 2
3 13 1456.56 20 14.46 2318 670 2.62 / 259.33 2 2
4 13 902.04 20 14.65 1584 464 3.09 / 259.80 2 2
5 13 333.36 20 14.91 811 242 3.33 / 260.04 2 2
6 8 -0.20 175 15.04 326 858 4.18 / 260.90 2 3
7 14 -0.20 30 15.02 331 149 4.33 / 261.05 2 2
Average= 4.21
(KJ/cycle)

Cycle 60 GMT 25/ 5/2019 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 21 15.00 485 153 0.15 / 252.57 2 2
2 7 2004.28 42 14.27 2979 1785 1.94 / 254.35 2 2
3 13 1592.68 20 14.43 2492 719 2.66 / 255.07 2 2
4 13 1022.04 20 14.61 1733 506 3.16 / 255.58 2 2
5 13 431.84 20 14.87 938 279 3.44 / 255.86 2 2
6 8 0.28 175 15.04 324 853 4.30 / 256.71 2 3
Average= 4.21
(KJ/cycle)

Cycle 59 GMT 15/ 5/2019 12:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 21 15.01 478 151 0.15 / 248.33 2 2
2 7 2003.52 42 14.26 2998 1796 1.95 / 250.12 2 2
3 13 1584.20 20 14.43 2483 717 2.66 / 250.84 2 2
4 13 1005.44 20 14.62 1716 502 3.16 / 251.34 2 2
5 13 281.12 20 14.95 735 220 3.38 / 251.56 2 2
6 8 -0.04 175 15.05 325 856 4.24 / 252.42 2 2
Average= 4.21
(KJ/cycle)

Cycle 58 GMT 5/ 5/2019 11:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 21 15.01 482 152 0.15 / 244.08 2 2
2 7 2002.20 42 14.27 2989 1791 1.94 / 245.88 2 2
3 13 1574.76 20 14.44 2478 716 2.66 / 246.59 2 2
4 13 1007.24 20 14.62 1720 503 3.16 / 247.09 2 2
5 13 291.00 20 14.94 754 225 3.39 / 247.32 2 2
6 8 0.28 175 15.05 325 856 4.24 / 248.18 2 9
Average= 4.21
(KJ/cycle)

Cycle 57 GMT 25/ 4/2019 11:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 20 15.01 479 144 0.14 / 239.54 2 2
2 3 1043.32 1 15.02 1895 28 0.17 / 239.57 2 2
3 7 2004.60 42 14.27 2991 1793 1.96 / 241.36 2 2
4 13 1585.16 20 14.43 2486 717 2.68 / 242.08 2 2
5 13 877.96 20 14.68 1551 455 3.14 / 242.53 2 2
6 13 442.20 20 14.87 957 285 3.42 / 242.82 2 2
7 13 28.48 20 15.08 375 113 3.54 / 242.93 2 2
8 8 0.00 175 15.05 324 853 4.39 / 243.79 2 2
9 14 0.00 30 15.03 327 147 4.54 / 243.93 2 4
Average= 4.21
(KJ/cycle)

Cycle 56 GMT 15/ 4/2019 11: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 21 15.01 476 150 0.15 / 235.22 2 2
2 3 960.04 -1 15.46 0 0 0.00 / 235.22 2 2
3 7 2005.76 43 14.27 2997 1839 1.99 / 237.06 2 2
4 13 1582.44 20 14.44 2490 719 2.71 / 237.78 2 2
5 13 872.72 20 14.68 1547 454 3.16 / 238.23 2 2
6 13 176.32 20 15.01 591 177 3.34 / 238.41 2 2
7 13 38.40 20 15.08 391 118 3.46 / 238.53 2 2
8 8 0.00 175 15.05 329 867 4.32 / 239.40 2 10
Average= 4.20
(KJ/cycle)

Cycle 55 GMT 5/ 4/2019 10:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 21 15.02 481 152 0.15 / 230.85 2 2
2 3 1031.56 1 15.07 1872 28 0.18 / 230.88 2 2
3 7 2001.64 42 14.28 2991 1794 1.97 / 232.67 2 2
4 13 1597.12 20 14.44 2497 721 2.69 / 233.39 2 2
5 13 892.00 20 14.68 1567 460 3.16 / 233.85 2 2
6 13 334.96 20 14.93 812 242 3.40 / 234.09 2 2
7 13 39.20 20 15.08 391 118 3.52 / 234.21 2 2
8 8 -0.04 175 15.05 327 861 4.38 / 235.07 2 5
Average= 4.20
(KJ/cycle)

Cycle 54 GMT 26/ 3/2019 10:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 21 15.03 485 153 0.15 / 226.53 2 2
2 7 2003.96 42 14.28 2988 1792 1.95 / 228.32 2 2
3 13 1591.28 20 14.44 2490 719 2.66 / 229.04 2 2
4 13 1023.16 20 14.63 1735 508 3.17 / 229.55 2 2
5 13 434.88 20 14.88 954 284 3.46 / 229.83 2 2
6 8 0.32 175 15.06 328 864 4.32 / 230.70 2 4
Average= 4.19
(KJ/cycle)

Cycle 53 GMT 16/ 3/2019 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 21 15.02 483 152 0.15 / 222.31 2 2
2 7 2002.08 42 14.28 3012 1806 1.96 / 224.12 2 2
3 13 1602.68 20 14.44 2506 724 2.68 / 224.84 2 2
4 13 905.28 20 14.68 1597 469 3.15 / 225.31 2 2
5 13 216.84 20 15.00 649 195 3.35 / 225.51 2 2
6 8 0.16 175 15.07 330 870 4.22 / 226.38 2 2
Average= 4.19
(KJ/cycle)

Cycle 52 GMT 6/ 3/2019 9:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 21 15.03 485 153 0.15 / 217.93 2 2
2 7 2003.24 42 14.29 2993 1796 1.95 / 219.73 2 2
3 13 1590.28 20 14.45 2486 718 2.67 / 220.45 2 2
4 13 1011.80 20 14.64 1725 505 3.17 / 220.95 2 2
5 13 301.60 20 14.96 768 230 3.40 / 221.18 2 2
6 13 17.44 20 15.10 360 109 3.51 / 221.29 2 2
7 8 -0.20 175 15.06 329 867 4.38 / 222.16 2 3
Average= 4.19
(KJ/cycle)

Cycle 51 GMT 24/ 2/2019 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 21 15.03 475 150 0.15 / 213.62 2 2
2 3 1018.36 1 15.13 1865 28 0.18 / 213.65 2 2
3 7 2003.64 42 14.29 3015 1810 1.99 / 215.46 2 2
4 13 1589.20 20 14.46 2483 718 2.71 / 216.17 2 2
5 13 1013.96 20 14.64 1723 504 3.21 / 216.68 2 2
6 13 302.76 20 14.96 763 228 3.44 / 216.91 2 2
7 8 0.20 175 15.07 331 873 4.31 / 217.78 2 3
Average= 4.19
(KJ/cycle)

Cycle 50 GMT 14/ 2/2019 8:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 21 15.03 480 152 0.15 / 209.37 2 2
2 7 2005.52 42 14.30 3001 1802 1.95 / 211.18 2 2
3 13 1476.36 20 14.50 2347 681 2.63 / 211.86 2 2
4 13 1048.68 20 14.63 1761 515 3.15 / 212.37 2 2
5 13 307.04 20 14.96 777 232 3.38 / 212.60 2 2
6 8 0.12 175 15.07 328 865 4.25 / 213.47 2 2
Average= 4.19
(KJ/cycle)

Cycle 49 GMT 4/ 2/2019 8:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 20 15.03 497 149 0.15 / 205.10 2 2
2 7 2004.48 42 14.30 3005 1805 1.95 / 206.90 2 2
3 13 1598.36 20 14.46 2503 724 2.68 / 207.63 2 2
4 13 1020.92 20 14.64 1746 511 3.19 / 208.14 2 2
5 13 298.92 20 14.97 755 226 3.42 / 208.36 2 2
6 8 0.04 175 15.08 325 858 4.27 / 209.22 2 3
Average= 4.18
(KJ/cycle)

Cycle 48 GMT 25/ 1/2019 8:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 21 15.03 492 155 0.16 / 200.80 2 2
2 7 2002.68 42 14.31 2986 1795 1.95 / 202.59 2 2
3 13 1469.00 20 14.50 2332 676 2.63 / 203.27 2 2
4 13 1048.84 20 14.63 1767 517 3.14 / 203.79 2 2
5 13 466.48 20 14.88 994 296 3.44 / 204.08 2 2
6 8 0.24 175 15.07 329 868 4.31 / 204.95 2 2
Average= 4.18
(KJ/cycle)

Cycle 47 GMT 15/ 1/2019 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 21 15.04 482 152 0.15 / 196.56 2 2
2 7 2004.08 42 14.30 3000 1802 1.95 / 198.36 2 2
3 13 1590.76 20 14.46 2495 722 2.68 / 199.08 2 2
4 13 885.40 20 14.71 1559 459 3.13 / 199.54 2 2
5 13 318.04 20 14.96 794 238 3.37 / 199.78 2 2
6 8 0.08 175 15.08 327 863 4.23 / 200.64 2 2
Average= 4.18
(KJ/cycle)

Cycle 46 GMT 5/ 1/2019 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 21 15.04 480 152 0.15 / 192.29 2 2
2 7 2003.92 43 14.30 3010 1851 2.00 / 194.14 2 2
3 13 1724.80 20 14.42 2665 769 2.77 / 194.91 2 2
4 13 862.84 20 14.72 1532 451 3.22 / 195.36 2 2
5 13 169.88 20 15.04 583 175 3.40 / 195.54 2 2
6 8 0.00 175 15.08 329 868 4.27 / 196.41 2 3
Average= 4.18
(KJ/cycle)

Cycle 45 GMT 26/12/2018 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 20 15.03 503 151 0.15 / 188.12 2 2
2 7 2005.08 42 14.32 2981 1793 1.94 / 189.91 2 2
3 13 1591.36 20 14.48 2488 721 2.66 / 190.63 2 2
4 13 896.28 20 14.71 1568 461 3.13 / 191.09 2 2
5 13 202.68 20 15.03 623 187 3.31 / 191.28 2 2
6 8 0.12 175 15.09 326 861 4.17 / 192.14 2 3
Average= 4.18
(KJ/cycle)

Cycle 44 GMT 16/12/2018 6: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 21 15.04 488 154 0.15 / 183.76 2 2
2 7 2004.96 42 14.32 2982 1793 1.95 / 185.56 2 2
3 13 1597.92 20 14.47 2499 723 2.67 / 186.28 2 2
4 13 1012.52 20 14.67 1716 503 3.17 / 186.78 2 2
5 13 286.28 20 14.99 735 220 3.39 / 187.00 2 2
6 13 28.52 20 15.11 374 113 3.51 / 187.12 2 2
7 8 0.12 175 15.08 322 850 4.36 / 187.97 2 4
Average= 4.18
(KJ/cycle)

Cycle 43 GMT 6/12/2018 5:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 21 15.04 493 156 0.16 / 179.55 2 2
2 7 2005.64 42 14.32 2973 1788 1.94 / 181.34 2 2
3 13 1601.36 20 14.47 2507 726 2.67 / 182.07 2 2
4 13 1028.28 20 14.66 1729 507 3.18 / 182.57 2 2
5 13 183.20 20 15.05 591 178 3.35 / 182.75 2 2
6 8 0.28 175 15.09 325 858 4.21 / 183.61 2 4
Average= 4.17
(KJ/cycle)

Cycle 42 GMT 26/11/2018 5:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 21 15.04 485 153 0.15 / 175.32 2 2
2 7 2002.72 42 14.33 2975 1791 1.94 / 177.11 2 2
3 13 1574.64 20 14.49 2452 711 2.65 / 177.82 2 2
4 13 990.28 20 14.68 1684 494 3.15 / 178.32 2 2
5 13 274.32 20 15.00 723 217 3.37 / 178.53 2 2
6 8 0.28 175 15.09 327 864 4.23 / 179.40 2 3
Average= 4.17
(KJ/cycle)

Cycle 41 GMT 16/11/2018 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 21 15.04 481 152 0.15 / 171.00 2 2
2 3 1024.44 1 15.13 1879 28 0.18 / 171.03 2 2
3 7 2005.12 43 14.32 2976 1833 2.01 / 172.86 2 2
4 13 1590.84 20 14.48 2489 721 2.73 / 173.58 2 2
5 13 1007.16 20 14.67 1709 501 3.24 / 174.08 2 2
6 13 276.52 20 15.00 725 217 3.45 / 174.30 2 2
7 8 0.00 175 15.09 329 869 4.32 / 175.17 2 5
Average= 4.17
(KJ/cycle)

Cycle 40 GMT 6/11/2018 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 22 15.04 491 162 0.16 / 166.70 2 2
2 3 958.36 -1 15.49 0 0 0.00 / 166.70 2 2
3 7 2001.80 43 14.32 2977 1833 2.00 / 168.54 2 2
4 13 1587.88 20 14.49 2476 718 2.71 / 169.25 2 2
5 13 1010.56 20 14.68 1719 505 3.22 / 169.76 2 2
6 13 276.56 20 15.01 724 217 3.44 / 169.98 2 2
7 8 -0.04 175 15.09 330 871 4.31 / 170.85 2 2
Average= 4.17
(KJ/cycle)

Cycle 39 GMT 27/10/2018 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 21 15.04 493 156 0.16 / 162.32 2 2
2 3 1043.96 1 15.05 1879 28 0.18 / 162.35 2 2
3 7 2004.00 42 14.33 3007 1810 1.99 / 164.16 2 2
4 13 1595.28 20 14.49 2498 724 2.72 / 164.89 2 2
5 13 1016.20 20 14.67 1727 507 3.22 / 165.39 2 2
6 13 408.84 20 14.94 916 274 3.50 / 165.67 2 2
7 8 0.04 175 15.09 331 874 4.37 / 166.54 2 2
Average= 4.16
(KJ/cycle)

Cycle 38 GMT 17/10/2018 3:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 21 15.04 505 159 0.16 / 158.08 2 2
2 7 2004.84 42 14.33 3000 1806 1.97 / 159.88 2 2
3 13 1461.36 20 14.53 2316 673 2.64 / 160.55 2 2
4 13 1027.72 20 14.67 1735 509 3.15 / 161.06 2 2
5 13 299.96 20 15.00 758 227 3.37 / 161.29 2 2
6 8 0.16 175 15.10 332 877 4.25 / 162.17 2 4
Average= 4.16
(KJ/cycle)

Cycle 37 GMT 7/10/2018 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 21 15.04 491 155 0.16 / 153.61 2 2
2 7 2002.32 42 14.53 3032 1850 2.01 / 155.46 2 2
3 13 1566.08 20 14.51 2451 711 2.72 / 156.17 2 2
4 13 985.72 20 14.69 1685 495 3.21 / 156.67 2 2
5 13 406.20 20 14.95 911 272 3.48 / 156.94 2 2
6 13 20.20 20 15.13 364 110 3.59 / 157.05 2 2
7 8 0.20 175 15.09 329 869 4.46 / 157.92 2 3
Average= 4.16
(KJ/cycle)

Cycle 36 GMT 27/ 9/2018 2:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 21 15.05 482 152 0.15 / 149.27 2 2
2 7 2004.60 42 14.34 2986 1798 1.95 / 151.07 2 2
3 13 1595.44 20 14.49 2493 722 2.67 / 151.79 2 2
4 13 1017.68 20 14.68 1723 506 3.18 / 152.29 2 2
5 13 432.16 20 14.93 947 283 3.46 / 152.58 2 2
6 8 0.32 175 15.10 332 877 4.34 / 153.45 2 2
Average= 4.15
(KJ/cycle)

Cycle 35 GMT 17/ 9/2018 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 21 15.05 486 154 0.15 / 145.03 2 2
2 7 2003.08 42 14.35 2976 1794 1.95 / 146.83 2 2
3 13 1587.28 20 14.51 2472 717 2.66 / 147.55 2 2
4 13 889.72 20 14.74 1559 460 3.12 / 148.01 2 2
5 13 323.80 20 14.99 791 237 3.36 / 148.24 2 2
6 8 0.00 175 15.10 330 872 4.23 / 149.11 2 2
Average= 4.14
(KJ/cycle)

Cycle 34 GMT 7/ 9/2018 1:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 20 15.05 490 147 0.15 / 140.71 2 2
2 3 1026.80 1 15.12 1880 28 0.18 / 140.74 2 2
3 7 2003.44 43 14.35 2977 1837 2.01 / 142.58 2 2
4 13 1578.64 20 14.51 2460 714 2.73 / 143.29 2 2
5 13 1007.16 20 14.70 1708 502 3.23 / 143.80 2 2
6 13 272.48 20 15.03 717 216 3.44 / 144.01 2 2
7 8 0.16 175 15.11 329 870 4.31 / 144.88 2 2
Average= 4.14
(KJ/cycle)

Cycle 33 GMT 28/ 8/2018 1:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 20 15.06 489 147 0.15 / 136.50 2 2
2 7 2002.72 42 14.35 2973 1792 1.94 / 138.30 2 2
3 13 1585.44 20 14.51 2472 717 2.66 / 139.01 2 2
4 13 880.48 20 14.75 1547 456 3.11 / 139.47 2 2
5 13 307.44 20 15.00 772 232 3.34 / 139.70 2 2
6 8 -0.20 175 15.11 327 865 4.21 / 140.57 2 3
Average= 4.13
(KJ/cycle)

Cycle 32 GMT 18/ 8/2018 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 20 15.06 501 151 0.15 / 132.30 2 2
2 7 2003.64 42 14.36 2971 1792 1.94 / 134.09 2 2
3 13 1586.92 20 14.52 2467 716 2.66 / 134.80 2 2
4 13 1018.84 20 14.70 1715 504 3.16 / 135.31 2 2
5 13 180.20 20 15.07 593 179 3.34 / 135.49 2 2
6 8 0.64 175 15.11 329 870 4.21 / 136.36 2 3
Average= 4.13
(KJ/cycle)

Cycle 31 GMT 8/ 8/2018 0:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 20 15.06 495 149 0.15 / 127.89 2 2
2 7 2001.64 42 14.37 2973 1794 1.94 / 129.68 2 2
3 13 1588.00 20 14.52 2470 717 2.66 / 130.40 2 2
4 13 1006.96 20 14.71 1703 501 3.16 / 130.90 2 2
5 13 429.68 20 14.95 941 281 3.44 / 131.18 2 2
6 13 10.32 20 15.15 350 106 3.55 / 131.29 2 2
7 8 0.36 175 15.11 325 859 4.41 / 132.15 2 5
Average= 4.13
(KJ/cycle)

Cycle 30 GMT 29/ 7/2018 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 21 15.07 487 154 0.15 / 123.73 2 2
2 7 2002.36 42 14.37 2977 1797 1.95 / 125.52 2 2
3 13 1579.52 20 14.52 2471 718 2.67 / 126.24 2 2
4 13 868.80 20 14.76 1528 451 3.12 / 126.69 2 2
5 13 169.92 20 15.08 578 174 3.29 / 126.87 2 2
6 8 0.04 175 15.12 329 871 4.16 / 127.74 2 2
Average= 4.12
(KJ/cycle)

Cycle 29 GMT 18/ 7/2018 23:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 20 15.07 484 146 0.15 / 119.48 2 2
2 7 2003.20 42 14.37 2970 1793 1.94 / 121.27 2 2
3 13 1589.88 20 14.52 2470 717 2.66 / 121.99 2 2
4 13 1013.16 20 14.71 1708 502 3.16 / 122.49 2 2
5 13 287.16 20 15.03 736 221 3.38 / 122.71 2 2
6 8 0.20 175 15.12 325 860 4.24 / 123.57 2 3
Average= 4.12
(KJ/cycle)

Cycle 28 GMT 8/ 7/2018 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 20 15.08 499 150 0.15 / 115.25 2 2
2 7 2003.80 42 14.36 2972 1792 1.94 / 117.05 2 2
3 13 1578.24 20 14.53 2442 710 2.65 / 117.75 2 2
4 13 995.24 20 14.71 1691 497 3.15 / 118.25 2 2
5 13 274.32 20 15.03 726 218 3.37 / 118.47 2 2
6 8 0.24 175 15.12 326 863 4.23 / 119.33 2 3
Average= 4.11
(KJ/cycle)

Cycle 27 GMT 28/ 6/2018 22:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 20 15.07 489 147 0.15 / 111.14 2 2
2 7 2001.88 42 14.38 2968 1793 1.94 / 112.93 2 2
3 13 1455.60 20 14.58 2295 669 2.61 / 113.60 2 2
4 13 893.28 20 14.76 1562 461 3.07 / 114.06 2 2
5 13 188.00 20 15.08 596 180 3.25 / 114.24 2 2
6 8 0.04 175 15.13 326 863 4.11 / 115.10 2 2
Average= 4.11
(KJ/cycle)

Cycle 26 GMT 18/ 6/2018 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 20 15.09 491 148 0.15 / 106.86 2 2
2 7 2004.20 43 14.38 2989 1848 2.00 / 108.71 2 2
3 13 1460.56 20 14.57 2299 670 2.67 / 109.38 2 2
4 13 898.32 20 14.76 1568 463 3.13 / 109.84 2 2
5 13 186.80 20 15.08 601 181 3.31 / 110.02 2 2
6 13 20.04 20 15.16 360 109 3.42 / 110.13 2 2
7 8 0.24 175 15.12 325 860 4.28 / 110.99 2 2
Average= 4.11
(KJ/cycle)

Cycle 25 GMT 8/ 6/2018 21:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 20 15.09 490 148 0.15 / 102.62 2 2
2 7 2003.40 42 14.39 2973 1797 1.94 / 104.41 2 2
3 13 1587.36 20 14.54 2471 719 2.66 / 105.13 2 2
4 13 1008.48 20 14.72 1708 503 3.17 / 105.63 2 2
5 13 290.32 20 15.04 746 224 3.39 / 105.86 2 2
6 8 0.16 175 15.14 321 850 4.24 / 106.71 2 2
Average= 4.10
(KJ/cycle)

Cycle 24 GMT 29/ 5/2018 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 21 15.09 492 156 0.16 / 98.46 2 2
2 7 2004.48 43 14.39 2970 1838 1.99 / 100.30 2 2
3 13 1449.88 20 14.58 2300 671 2.66 / 100.97 2 2
4 13 897.36 20 14.77 1564 462 3.13 / 101.43 2 2
5 13 175.76 20 15.10 590 178 3.30 / 101.61 2 2
6 8 0.24 175 15.14 325 861 4.17 / 102.47 2 3
Average= 4.10
(KJ/cycle)

Cycle 23 GMT 19/ 5/2018 20:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 20 15.09 489 148 0.15 / 94.27 2 2
2 7 2002.16 42 14.39 2979 1800 1.95 / 96.07 2 2
3 13 1454.76 20 14.59 2301 671 2.62 / 96.74 2 2
4 13 897.00 20 14.77 1573 465 3.08 / 97.21 2 2
5 13 324.96 20 15.02 798 240 3.32 / 97.45 2 2
6 8 0.44 175 15.14 323 856 4.18 / 98.30 2 4
Average= 4.10
(KJ/cycle)

Cycle 22 GMT 9/ 5/2018 20:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 21 15.10 490 155 0.16 / 90.04 2 2
2 7 2004.72 42 14.40 2999 1814 1.97 / 91.85 2 2
3 13 1595.76 20 14.55 2488 724 2.69 / 92.57 2 2
4 13 886.92 20 14.78 1554 459 3.15 / 93.03 2 2
5 13 318.64 20 15.03 788 237 3.39 / 93.27 2 2
6 8 -0.08 175 15.15 322 854 4.24 / 94.12 2 2
Average= 4.09
(KJ/cycle)

Cycle 21 GMT 29/ 4/2018 19:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 21 15.10 486 154 0.15 / 85.87 2 2
2 7 2003.84 43 14.40 2986 1849 2.00 / 87.72 2 2
3 13 1448.24 20 14.60 2281 666 2.67 / 88.38 2 2
4 13 895.28 20 14.78 1563 462 3.13 / 88.85 2 2
5 13 167.52 20 15.11 571 173 3.30 / 89.02 2 2
6 8 0.40 175 15.15 325 862 4.17 / 89.88 2 2
Average= 4.09
(KJ/cycle)

Cycle 20 GMT 19/ 4/2018 19:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 20 15.10 475 143 0.14 / 81.63 2 2
2 3 1031.20 1 15.15 1874 28 0.17 / 81.66 2 2
3 7 2001.88 42 14.42 2975 1802 1.97 / 83.46 2 2
4 13 1580.12 20 14.57 2461 717 2.69 / 84.18 2 2
5 13 871.84 20 14.80 1538 455 3.15 / 84.63 2 2
6 13 300.28 20 15.05 760 229 3.37 / 84.86 2 2
7 8 0.16 175 15.16 322 854 4.23 / 85.71 2 8
Average= 4.08
(KJ/cycle)

Cycle 19 GMT 9/ 4/2018 19: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 21 15.12 482 153 0.15 / 77.26 2 2
2 3 948.92 -1 15.54 0 0 0.00 / 77.26 2 2
3 7 2001.28 42 14.42 2971 1799 1.95 / 79.06 2 2
4 13 1592.60 20 14.57 2473 721 2.67 / 79.78 2 2
5 13 1017.68 20 14.74 1718 506 3.18 / 80.29 2 2
6 13 294.60 20 15.06 753 227 3.41 / 80.52 2 2
7 13 33.48 20 15.18 375 114 3.52 / 80.63 2 2
8 8 -0.08 175 15.15 323 856 4.38 / 81.49 2 8
Average= 4.07
(KJ/cycle)

Cycle 18 GMT 30/ 3/2018 18:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 21 15.13 472 150 0.15 / 72.98 2 2
2 3 1020.80 1 15.22 1865 28 0.18 / 73.01 2 2
3 7 2004.16 42 14.42 2990 1811 1.99 / 74.82 2 2
4 13 1580.52 20 14.58 2467 719 2.71 / 75.54 2 2
5 13 995.44 20 14.75 1687 498 3.21 / 76.04 2 2
6 13 275.72 20 15.07 723 218 3.42 / 76.25 2 2
7 8 0.32 175 15.16 322 854 4.28 / 77.11 2 3
Average= 4.06
(KJ/cycle)

Cycle 17 GMT 20/ 3/2018 18:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 21 15.13 477 152 0.15 / 68.78 2 2
2 7 2003.12 42 14.43 2981 1807 1.96 / 70.59 2 2
3 13 1583.60 20 14.58 2458 717 2.67 / 71.30 2 2
4 13 872.28 20 14.80 1534 454 3.13 / 71.76 2 2
5 13 302.92 20 15.06 760 229 3.36 / 71.99 2 2
6 8 -0.16 175 15.17 318 844 4.20 / 72.83 2 3
Average= 4.05
(KJ/cycle)

Cycle 16 GMT 10/ 3/2018 17:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 21 15.14 465 148 0.15 / 64.61 2 2
2 7 2003.28 42 14.43 2983 1808 1.96 / 66.42 2 2
3 13 1569.92 19 14.59 2452 680 2.64 / 67.10 2 2
4 13 996.76 19 14.76 1691 474 3.11 / 67.57 2 2
5 13 285.20 19 15.07 742 212 3.32 / 67.78 2 2
6 8 0.04 175 15.17 318 844 4.17 / 68.63 2 5
Average= 4.04
(KJ/cycle)

Cycle 15 GMT 28/ 2/2018 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 22 15.13 476 158 0.16 / 60.34 2 2
2 7 2002.52 42 14.45 2971 1803 1.96 / 62.14 2 2
3 13 1590.76 19 14.59 2494 691 2.65 / 62.83 2 2
4 13 904.92 19 14.80 1575 443 3.10 / 63.27 2 2
5 13 341.88 19 15.05 813 232 3.33 / 63.51 2 2
6 13 38.72 19 15.19 379 109 3.44 / 63.62 2 2
7 8 0.24 175 15.17 319 847 4.28 / 64.46 2 7
Average= 4.03
(KJ/cycle)

Cycle 14 GMT 18/ 2/2018 16:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 20 15.14 472 143 0.14 / 56.01 2 2
2 3 1061.64 2 15.08 1886 57 0.20 / 56.07 2 2
3 7 2001.68 43 14.44 2982 1852 2.05 / 57.92 2 2
4 13 1450.20 19 14.63 2295 638 2.69 / 58.56 2 2
5 13 904.96 19 14.80 1579 444 3.13 / 59.00 2 2
6 13 328.04 19 15.06 791 226 3.36 / 59.23 2 2
7 13 34.08 19 15.20 376 109 3.47 / 59.34 2 2
8 8 -0.12 175 15.17 317 842 4.31 / 60.18 2 7
Average= 4.01
(KJ/cycle)

Cycle 13 GMT 8/ 2/2018 16:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 22 15.13 470 156 0.16 / 51.74 2 2
2 3 932.48 -1 15.56 0 0 0.00 / 51.74 2 2
3 7 2001.68 42 14.45 2996 1818 1.97 / 53.56 2 2
4 13 1720.72 19 14.56 2649 733 2.71 / 54.29 2 2
5 13 982.32 19 14.78 1671 469 3.18 / 54.76 2 2
6 13 409.64 19 15.02 910 260 3.44 / 55.02 2 2
7 8 0.36 175 15.18 319 847 4.28 / 55.87 2 3
Average= 3.99
(KJ/cycle)

Cycle 12 GMT 29/ 1/2018 16: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 22 15.14 466 155 0.16 / 47.19 2 2
2 7 2003.40 42 14.46 2975 1807 1.96 / 49.00 2 2
3 13 1588.84 19 14.60 2475 687 2.65 / 49.68 2 2
4 13 1008.52 19 14.77 1713 481 3.13 / 50.16 2 2
5 13 421.96 19 15.02 924 264 3.39 / 50.43 2 2
6 8 0.32 175 15.19 317 843 4.24 / 51.27 2 3
7 14 0.32 65 15.15 319 314 4.55 / 51.58 2 9
Average= 3.97
(KJ/cycle)

Cycle 11 GMT 19/ 1/2018 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 22 15.14 480 160 0.16 / 42.96 2 2
2 3 965.72 -1 15.57 0 0 0.00 / 42.96 2 2
3 3 1030.88 1 15.22 1882 29 0.19 / 42.99 2 2
4 7 2006.12 44 14.45 3001 1908 2.10 / 44.90 2 2
5 13 1450.24 19 14.64 2295 638 2.73 / 45.53 2 2
6 13 887.92 19 14.82 1557 438 3.17 / 45.97 2 2
7 13 298.44 19 15.08 750 215 3.39 / 46.19 2 2
8 8 0.32 175 15.18 319 847 4.24 / 47.03 2 3
Average= 3.92
(KJ/cycle)

Cycle 10 GMT 9/ 1/2018 14:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 22 15.14 476 159 0.16 / 38.83 2 2
2 7 2003.44 44 14.46 2970 1890 2.05 / 40.72 2 2
3 13 1440.32 19 14.65 2266 631 2.68 / 41.35 2 2
4 13 872.72 19 14.83 1536 433 3.11 / 41.78 2 2
5 13 166.92 19 15.15 567 163 3.27 / 41.95 2 2
6 8 0.08 175 15.19 320 851 4.13 / 42.80 2 3
Average= 3.89
(KJ/cycle)

Cycle 9 GMT 30/12/2017 14:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 21 15.15 469 149 0.15 / 34.62 2 2
2 3 1024.36 1 15.23 1887 29 0.18 / 34.64 2 2
3 7 2001.48 45 14.46 2996 1949 2.13 / 36.59 2 2
4 13 1436.52 19 14.66 2276 634 2.76 / 37.23 2 2
5 13 867.32 19 14.84 1530 431 3.19 / 37.66 2 2
6 13 157.08 19 15.16 556 160 3.35 / 37.82 2 2
7 8 0.24 175 15.19 321 853 4.21 / 38.67 2 4
Average= 3.87
(KJ/cycle)

Cycle 8 GMT 20/12/2017 13:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 22 15.14 470 157 0.16 / 30.39 2 2
2 3 936.00 -1 15.57 0 0 0.00 / 30.39 2 2
3 7 2001.84 44 14.46 2985 1899 2.06 / 32.29 2 2
4 13 1433.76 22 14.65 2271 732 2.79 / 33.02 2 2
5 13 734.36 22 14.88 1357 444 3.23 / 33.46 2 2
6 13 74.72 22 15.19 438 146 3.38 / 33.61 2 2
7 8 0.20 175 15.19 322 856 4.23 / 34.47 2 3
Average= 3.83
(KJ/cycle)

Cycle 7 GMT 10/12/2017 13:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 22 15.14 477 159 0.16 / 26.07 2 2
2 3 1032.16 1 15.21 1876 29 0.19 / 26.10 2 2
3 7 2003.28 45 14.46 2994 1948 2.14 / 28.05 2 2
4 13 1450.80 22 14.64 2299 740 2.88 / 28.79 2 2
5 13 741.52 22 14.88 1368 448 3.32 / 29.23 2 2
6 13 74.80 22 15.20 435 145 3.47 / 29.38 2 2
7 8 0.16 175 15.19 321 853 4.32 / 30.23 2 3
Average= 3.78
(KJ/cycle)

Cycle 6 GMT 30/11/2017 12:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 23 15.14 492 171 0.17 / 21.80 2 2
2 3 973.32 -1 15.60 0 0 0.00 / 21.80 2 2
3 7 2001.12 44 14.48 2970 1892 2.06 / 23.69 2 2
4 13 1436.28 22 14.65 2267 731 2.79 / 24.42 2 2
5 13 860.64 22 14.84 1519 496 3.29 / 24.92 2 2
6 13 65.96 22 15.20 423 141 3.43 / 25.06 2 2
7 8 0.24 175 15.19 321 853 4.28 / 25.91 2 6
Average= 3.70
(KJ/cycle)

Cycle 5 GMT 20/11/2017 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 23 15.15 482 168 0.17 / 17.44 2 2
2 3 966.92 -1 15.58 0 0 0.00 / 17.44 2 2
3 7 2003.00 44 14.49 2976 1897 2.07 / 19.33 2 2
4 13 1556.40 22 14.62 2432 782 2.85 / 20.11 2 2
5 13 825.64 22 14.85 1480 484 3.33 / 20.60 2 2
6 13 107.36 22 15.18 487 163 3.49 / 20.76 2 2
7 8 0.36 175 15.19 325 864 4.36 / 21.62 2 3
Average= 3.60
(KJ/cycle)

Cycle 4 GMT 10/11/2017 11:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 20 15.15 478 145 0.14 / 13.41 2 2
2 3 1067.04 2 15.08 1896 57 0.20 / 13.46 2 2
3 7 1516.00 44 14.69 2376 1536 1.74 / 15.00 2 2
4 13 1253.68 22 14.77 2046 665 2.40 / 15.66 2 2
5 13 669.80 22 14.96 1269 418 2.82 / 16.08 2 2
6 8 0.12 240 15.21 325 1186 4.01 / 17.27 2 2
Average= 3.45
(KJ/cycle)

Cycle 3 GMT 9/11/2017 11:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 23 15.13 499 174 0.17 / 9.42 2 2
2 3 874.04 -2 15.57 0 0 0.00 / 9.42 2 2
3 3 957.16 -1 15.59 0 0 0.00 / 9.42 2 2
4 7 1511.76 44 14.69 2374 1534 1.71 / 10.95 2 2
5 13 1382.04 22 14.73 2217 718 2.43 / 11.67 2 2
6 13 650.32 22 14.96 1242 409 2.84 / 12.08 2 2
7 8 0.32 240 15.20 324 1182 4.02 / 13.26 2 2
Average= 3.32
(KJ/cycle)

Cycle 2 GMT 8/11/2017 12:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 24 15.15 487 177 0.18 / 5.29 2 2
2 3 946.52 -1 15.57 0 0 0.00 / 5.29 2 2
3 7 1506.48 74 14.61 2358 2549 2.73 / 7.84 2 2
4 13 167.32 25 15.16 572 217 2.94 / 8.05 2 2
5 8 0.12 240 15.18 327 1191 4.13 / 9.24 2 8
Average= 3.08
(KJ/cycle)

Cycle 1 GMT 7/11/2017 13:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 25 15.31 472 181 0.18 / 2.06 2 2
2 3 955.16 -1 15.56 0 0 0.00 / 2.06 2 2
3 7 997.40 74 14.79 1691 1851 2.03 / 3.91 2 2
4 8 0.12 240 15.21 328 1197 3.23 / 5.11 2 2
Average= 2.55
(KJ/cycle)

Cycle 0 GMT 7/11/2017 2:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 97.40 25 15.49 473 183 0.18 / 0.18 2 2
2 7 106.96 74 15.45 475 543 0.73 / 0.73 2 2
3 8 -0.04 240 15.41 312 1154 1.88 / 1.88 2 5
Average= 1.88
(KJ/cycle)