SIO Argo Site:
Pump Diagnostics Page   



Serial= 8587 WMO= 3901476

Return

←PreviousNext→

Cycle 264 GMT 21/12/2024 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 27 14.80 493 197 0.20 / 1162.21 2 2
2 7 2004.76 45 14.03 2892 1826 2.02 / 1164.04 2 2
3 13 1729.84 21 14.11 2551 756 2.78 / 1164.79 2 2
4 13 1142.32 21 14.32 1783 536 3.31 / 1165.33 2 2
5 13 542.24 21 14.61 1053 323 3.64 / 1165.65 2 2
6 8 0.52 170 14.86 346 874 4.51 / 1166.53 2 3
Average= 4.40
(KJ/cycle)

Cycle 263 GMT 11/12/2024 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 14.80 491 196 0.20 / 1157.76 2 2
2 7 2008.00 45 14.02 2899 1829 2.03 / 1159.59 2 2
3 13 1595.40 21 14.16 2374 706 2.73 / 1160.30 2 2
4 13 1025.68 21 14.38 1639 495 3.23 / 1160.79 2 2
5 13 581.28 21 14.59 1101 337 3.56 / 1161.13 2 2
6 8 -0.52 170 14.86 350 884 4.45 / 1162.01 2 3
Average= 4.40
(KJ/cycle)

Cycle 262 GMT 1/12/2024 22:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 14.80 501 208 0.21 / 1153.23 2 2
2 7 2002.12 45 14.04 2834 1791 2.00 / 1155.02 2 2
3 13 1718.96 21 14.13 2532 751 2.75 / 1155.77 2 2
4 13 1018.28 21 14.39 1632 493 3.24 / 1156.27 2 2
5 13 448.52 21 14.67 935 288 3.53 / 1156.55 2 2
6 13 14.36 21 14.90 374 117 3.65 / 1156.67 2 2
7 8 0.60 170 14.85 355 896 4.54 / 1157.57 2 4
Average= 4.40
(KJ/cycle)

Cycle 261 GMT 21/11/2024 22:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 26 14.80 510 196 0.20 / 1148.71 2 2
2 10 1016.32 3 14.72 1727 76 0.27 / 1148.79 2 2
3 7 2005.24 45 14.04 2868 1812 2.08 / 1150.60 2 2
4 13 1721.16 21 14.12 2521 748 2.83 / 1151.35 2 2
5 13 1009.12 21 14.40 1633 494 3.33 / 1151.84 2 2
6 13 441.00 21 14.68 924 285 3.61 / 1152.12 2 2
7 8 -0.28 170 14.86 356 899 4.51 / 1153.02 2 2
Average= 4.40
(KJ/cycle)

Cycle 260 GMT 11/11/2024 23:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 27 14.80 496 198 0.20 / 1144.30 2 2
2 3 969.84 -1 15.35 0 0 0.00 / 1144.30 2 2
3 7 2008.48 45 14.04 2876 1817 2.02 / 1146.12 2 2
4 13 1589.84 21 14.15 2379 707 2.72 / 1146.83 2 2
5 13 1041.04 21 14.38 1665 503 3.22 / 1147.33 2 2
6 13 469.32 21 14.66 958 295 3.52 / 1147.62 2 2
7 8 -0.04 170 14.87 352 890 4.41 / 1148.51 2 3
Average= 4.40
(KJ/cycle)

Cycle 259 GMT 1/11/2024 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 27 14.82 481 192 0.19 / 1139.74 2 2
2 7 2004.40 45 14.03 2891 1825 2.02 / 1141.57 2 2
3 13 1589.76 21 14.16 2362 702 2.72 / 1142.27 2 2
4 13 1165.08 21 14.32 1815 546 3.27 / 1142.81 2 2
5 13 447.52 21 14.67 932 287 3.55 / 1143.10 2 2
6 13 33.52 21 14.89 403 126 3.68 / 1143.23 2 2
7 8 0.04 170 14.86 347 877 4.56 / 1144.10 2 8
Average= 4.40
(KJ/cycle)

Cycle 258 GMT 22/10/2024 23:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 26 14.80 511 197 0.20 / 1135.38 2 2
2 3 1043.84 1 14.91 1775 26 0.22 / 1135.40 2 2
3 7 2003.48 45 14.04 2852 1802 2.02 / 1137.20 2 2
4 13 1605.68 21 14.16 2381 708 2.73 / 1137.91 2 2
5 13 1056.60 21 14.38 1684 509 3.24 / 1138.42 2 2
6 13 349.96 21 14.73 808 250 3.49 / 1138.67 2 2
7 8 0.28 170 14.87 347 877 4.37 / 1139.55 2 2
Average= 4.40
(KJ/cycle)

Cycle 257 GMT 12/10/2024 23:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 26 14.80 488 188 0.19 / 1130.98 2 2
2 7 2008.52 45 14.03 2875 1815 2.00 / 1132.79 2 2
3 13 1601.60 21 14.16 2378 707 2.71 / 1133.50 2 2
4 13 1033.68 21 14.40 1651 499 3.21 / 1134.00 2 2
5 13 476.32 21 14.67 967 298 3.51 / 1134.30 2 2
6 8 0.04 170 14.87 349 882 4.39 / 1135.18 2 2
Average= 4.40
(KJ/cycle)

Cycle 256 GMT 3/10/2024 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 26 14.79 507 195 0.19 / 1126.45 2 2
2 7 2004.92 45 14.04 2834 1791 1.99 / 1128.24 2 2
3 13 1724.24 21 14.12 2531 750 2.74 / 1128.99 2 2
4 13 1014.28 21 14.41 1648 499 3.23 / 1129.49 2 2
5 13 459.36 21 14.68 947 292 3.53 / 1129.78 2 2
6 13 34.32 21 14.89 406 127 3.65 / 1129.91 2 2
7 8 0.44 170 14.86 350 884 4.54 / 1130.79 2 3
Average= 4.40
(KJ/cycle)

Cycle 255 GMT 23/ 9/2024 0:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 26 14.78 496 191 0.19 / 1121.67 2 2
2 7 2004.96 45 14.04 2864 1809 2.00 / 1123.48 2 2
3 13 1615.32 21 14.16 2395 712 2.71 / 1124.19 2 2
4 13 1056.68 21 14.39 1684 509 3.22 / 1124.70 2 2
5 13 477.72 21 14.66 978 301 3.52 / 1125.00 2 2
6 8 0.08 170 14.86 353 892 4.41 / 1125.89 2 4
7 14 0.08 70 14.83 346 359 4.77 / 1126.25 2 3
Average= 4.40
(KJ/cycle)

Cycle 254 GMT 13/ 9/2024 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 27 14.81 491 196 0.20 / 1116.80 2 2
2 7 2009.36 45 14.04 2844 1797 1.99 / 1118.59 2 2
3 13 1478.64 21 14.20 2218 661 2.65 / 1119.25 2 2
4 13 1068.52 21 14.37 1689 510 3.16 / 1119.76 2 2
5 13 509.48 21 14.65 1008 310 3.47 / 1120.07 2 2
6 13 38.92 21 14.88 412 129 3.60 / 1120.20 2 2
7 8 -0.16 170 14.85 359 906 4.51 / 1121.11 2 4
8 14 -0.16 70 14.82 356 369 4.88 / 1121.48 2 3
Average= 4.40
(KJ/cycle)

Cycle 253 GMT 3/ 9/2024 0:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 27 14.81 482 193 0.19 / 1112.35 2 2
2 7 2003.68 45 14.03 2855 1803 2.00 / 1114.15 2 2
3 13 1602.88 21 14.17 2368 705 2.70 / 1114.86 2 2
4 13 1045.72 21 14.40 1664 503 3.20 / 1115.36 2 2
5 13 347.08 21 14.74 796 246 3.45 / 1115.61 2 2
6 13 21.04 21 14.90 383 120 3.57 / 1115.73 2 2
7 8 -0.44 170 14.86 345 872 4.44 / 1116.60 2 3
Average= 4.40
(KJ/cycle)

Cycle 252 GMT 24/ 8/2024 0:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 27 14.80 496 198 0.20 / 1107.94 2 2
2 7 2004.16 45 14.03 2869 1811 2.01 / 1109.75 2 2
3 13 1590.28 21 14.17 2363 703 2.71 / 1110.45 2 2
4 13 1148.36 21 14.35 1800 542 3.26 / 1111.00 2 2
5 13 432.84 21 14.69 914 282 3.54 / 1111.28 2 2
6 8 0.16 170 14.87 349 882 4.42 / 1112.16 2 2
Average= 4.40
(KJ/cycle)

Cycle 251 GMT 14/ 8/2024 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 26 14.80 498 192 0.19 / 1103.51 2 2
2 3 1035.72 1 14.91 1762 26 0.22 / 1103.53 2 2
3 7 2004.56 45 14.04 2859 1806 2.02 / 1105.34 2 2
4 13 1607.12 21 14.15 2389 710 2.73 / 1106.05 2 2
5 13 1036.48 21 14.40 1664 503 3.24 / 1106.55 2 2
6 13 463.88 21 14.66 958 295 3.53 / 1106.85 2 2
7 8 0.32 170 14.86 353 892 4.42 / 1107.74 2 3
Average= 4.40
(KJ/cycle)

Cycle 250 GMT 4/ 8/2024 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 27 14.78 510 204 0.20 / 1098.97 2 2
2 3 960.00 -1 15.31 0 0 0.00 / 1098.97 2 2
3 7 2003.12 46 14.03 2870 1852 2.06 / 1100.82 2 2
4 13 1730.24 21 14.13 2547 756 2.81 / 1101.57 2 2
5 13 1009.40 21 14.42 1632 494 3.31 / 1102.07 2 2
6 13 304.88 21 14.75 755 234 3.54 / 1102.30 2 2
7 13 33.48 21 14.88 409 128 3.67 / 1102.43 2 2
8 8 0.04 170 14.85 351 886 4.55 / 1103.32 2 5
Average= 4.40
(KJ/cycle)

Cycle 249 GMT 25/ 7/2024 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 26 14.79 497 191 0.19 / 1093.99 2 2
2 3 1037.48 1 14.88 1780 26 0.22 / 1094.01 2 2
3 7 2007.56 45 14.04 2878 1818 2.04 / 1095.83 2 2
4 13 1725.24 21 14.13 2543 755 2.79 / 1096.59 2 2
5 13 1134.68 21 14.37 1775 536 3.33 / 1097.12 2 2
6 13 409.84 21 14.69 884 273 3.60 / 1097.40 2 2
7 13 26.44 21 14.88 395 123 3.72 / 1097.52 2 2
8 8 -0.24 170 14.85 350 884 4.61 / 1098.40 2 11
9 14 -0.24 70 14.82 347 360 4.97 / 1098.76 2 5
Average= 4.40
(KJ/cycle)

Cycle 248 GMT 15/ 7/2024 1:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 27 14.79 491 196 0.20 / 1089.59 2 2
2 3 973.48 -1 15.29 0 0 0.00 / 1089.59 2 2
3 7 2002.92 45 14.04 2889 1825 2.02 / 1091.42 2 2
4 13 1587.68 21 14.18 2346 699 2.72 / 1092.12 2 2
5 13 1037.88 21 14.40 1661 502 3.22 / 1092.62 2 2
6 13 478.52 21 14.65 970 298 3.52 / 1092.92 2 2
7 8 -0.24 170 14.85 348 879 4.40 / 1093.80 2 4
Average= 4.39
(KJ/cycle)

Cycle 247 GMT 5/ 7/2024 1:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 27 14.80 492 197 0.20 / 1085.19 2 2
2 7 2007.92 45 14.03 2898 1830 2.03 / 1087.02 2 2
3 13 1599.28 21 14.17 2372 706 2.73 / 1087.73 2 2
4 13 1032.36 21 14.40 1649 499 3.23 / 1088.23 2 2
5 13 461.24 21 14.66 947 292 3.52 / 1088.52 2 2
6 8 0.08 170 14.85 348 879 4.40 / 1089.40 2 4
Average= 4.39
(KJ/cycle)

Cycle 246 GMT 25/ 6/2024 2: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 27 14.79 496 198 0.20 / 1080.79 2 2
2 7 2007.12 45 14.05 2834 1792 1.99 / 1082.58 2 2
3 13 1582.60 21 14.17 2363 703 2.69 / 1083.28 2 2
4 13 1018.72 21 14.41 1648 499 3.19 / 1083.78 2 2
5 13 584.48 21 14.60 1100 337 3.53 / 1084.12 2 2
6 8 0.08 170 14.85 348 879 4.41 / 1085.00 2 4
Average= 4.39
(KJ/cycle)

Cycle 245 GMT 15/ 6/2024 2:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 27 14.80 485 194 0.19 / 1076.38 2 2
2 7 2003.60 45 14.05 2855 1805 2.00 / 1078.18 2 2
3 13 1733.44 21 14.13 2545 755 2.75 / 1078.94 2 2
4 13 1010.16 21 14.41 1619 490 3.24 / 1079.43 2 2
5 13 448.96 21 14.67 930 287 3.53 / 1079.71 2 2
6 8 -0.08 170 14.85 347 876 4.41 / 1080.59 2 7
Average= 4.39
(KJ/cycle)

Cycle 244 GMT 5/ 6/2024 2:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 27 14.78 498 199 0.20 / 1071.94 2 2
2 7 2006.32 45 14.03 2889 1824 2.02 / 1073.77 2 2
3 13 1731.40 21 14.13 2522 748 2.77 / 1074.52 2 2
4 13 1024.48 21 14.40 1643 497 3.27 / 1075.01 2 2
5 13 462.04 21 14.66 955 294 3.56 / 1075.31 2 2
6 8 0.00 170 14.85 347 876 4.44 / 1076.18 2 2
Average= 4.39
(KJ/cycle)

Cycle 243 GMT 26/ 5/2024 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 27 14.79 487 194 0.19 / 1067.36 2 2
2 7 2004.68 45 14.06 2847 1801 2.00 / 1069.16 2 2
3 13 1729.08 21 14.12 2552 757 2.75 / 1069.91 2 2
4 13 1154.04 21 14.34 1812 546 3.30 / 1070.46 2 2
5 13 452.24 21 14.66 937 288 3.59 / 1070.75 2 2
6 13 16.08 21 14.87 382 119 3.71 / 1070.87 2 2
7 8 -0.28 170 14.83 348 877 4.58 / 1071.75 2 4
Average= 4.39
(KJ/cycle)

Cycle 242 GMT 16/ 5/2024 3:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 27 14.78 499 199 0.20 / 1062.97 2 2
2 7 2003.04 45 14.05 2868 1813 2.01 / 1064.79 2 2
3 13 1608.44 21 14.17 2381 709 2.72 / 1065.50 2 2
4 13 1179.44 21 14.33 1844 555 3.28 / 1066.05 2 2
5 13 327.08 21 14.71 779 241 3.52 / 1066.29 2 2
6 8 0.36 170 14.84 345 870 4.39 / 1067.16 2 3
Average= 4.39
(KJ/cycle)

Cycle 241 GMT 6/ 5/2024 3:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 14.78 482 199 0.20 / 1058.45 2 2
2 3 962.76 -1 15.28 0 0 0.00 / 1058.45 2 2
3 7 2004.60 45 14.05 2872 1816 2.02 / 1060.27 2 2
4 13 1593.32 21 14.18 2348 699 2.71 / 1060.97 2 2
5 13 1042.88 21 14.38 1674 506 3.22 / 1061.47 2 2
6 13 468.48 21 14.64 962 296 3.52 / 1061.77 2 2
7 13 39.88 21 14.85 411 128 3.64 / 1061.90 2 2
8 8 0.00 170 14.83 348 877 4.52 / 1062.77 2 3
Average= 4.39
(KJ/cycle)

Cycle 240 GMT 26/ 4/2024 3:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 28 14.79 494 205 0.20 / 1053.63 2 2
2 3 1027.52 1 14.91 1737 26 0.23 / 1053.66 2 2
3 7 2002.48 46 14.05 2883 1863 2.09 / 1055.52 2 2
4 13 1727.72 21 14.13 2519 747 2.84 / 1056.27 2 2
5 13 1012.40 21 14.40 1633 494 3.34 / 1056.76 2 2
6 13 433.80 21 14.66 906 279 3.61 / 1057.04 2 2
7 8 -0.20 170 14.84 342 863 4.48 / 1057.90 2 6
8 14 -0.20 70 14.82 339 352 4.83 / 1058.25 2 3
Average= 4.39
(KJ/cycle)

Cycle 239 GMT 16/ 4/2024 4: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 28 14.79 487 202 0.20 / 1049.26 2 2
2 7 2004.56 46 14.05 2874 1857 2.06 / 1051.11 2 2
3 13 1594.96 21 14.18 2319 691 2.75 / 1051.80 2 2
4 13 1036.52 21 14.39 1661 502 3.25 / 1052.31 2 2
5 13 346.08 21 14.70 801 247 3.50 / 1052.55 2 2
6 8 0.28 170 14.84 346 873 4.37 / 1053.43 2 2
Average= 4.39
(KJ/cycle)

Cycle 238 GMT 6/ 4/2024 4: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 28 14.79 494 205 0.20 / 1044.92 2 2
2 7 2005.64 45 14.06 2864 1812 2.02 / 1046.73 2 2
3 13 1596.64 21 14.18 2331 694 2.71 / 1047.43 2 2
4 13 1042.56 21 14.39 1673 506 3.22 / 1047.93 2 2
5 13 341.36 21 14.70 801 247 3.46 / 1048.18 2 2
6 8 0.04 170 14.84 347 875 4.34 / 1049.05 2 5
Average= 4.39
(KJ/cycle)

Cycle 237 GMT 27/ 3/2024 4:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 28 14.79 486 201 0.20 / 1040.52 2 2
2 7 2005.68 45 14.06 2864 1812 2.01 / 1042.34 2 2
3 13 1599.96 21 14.17 2371 706 2.72 / 1043.04 2 2
4 13 1034.52 21 14.39 1660 502 3.22 / 1043.54 2 2
5 13 470.72 21 14.63 965 296 3.52 / 1043.84 2 2
6 8 0.12 170 14.84 347 875 4.39 / 1044.71 2 3
Average= 4.39
(KJ/cycle)

Cycle 236 GMT 17/ 3/2024 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 14.80 496 206 0.21 / 1036.12 2 2
2 3 1018.52 1 14.94 1737 26 0.23 / 1036.15 2 2
3 7 2005.64 45 14.05 2891 1828 2.06 / 1037.97 2 2
4 13 1594.16 21 14.18 2372 706 2.77 / 1038.68 2 2
5 13 1027.28 21 14.39 1646 497 3.26 / 1039.18 2 2
6 13 447.80 21 14.65 926 285 3.55 / 1039.46 2 2
7 8 0.36 170 14.84 341 860 4.41 / 1040.32 2 3
Average= 4.39
(KJ/cycle)

Cycle 235 GMT 7/ 3/2024 4:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 14.80 480 199 0.20 / 1031.72 2 2
2 7 2005.04 45 14.07 2849 1804 2.00 / 1033.52 2 2
3 13 1728.24 21 14.14 2503 743 2.75 / 1034.26 2 2
4 13 1025.88 21 14.39 1647 498 3.24 / 1034.76 2 2
5 13 466.28 21 14.64 947 291 3.53 / 1035.05 2 2
6 8 0.08 170 14.84 342 863 4.40 / 1035.91 2 3
Average= 4.39
(KJ/cycle)

Cycle 234 GMT 26/ 2/2024 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.80 480 199 0.20 / 1027.40 2 2
2 7 2003.16 45 14.08 2851 1806 2.01 / 1029.21 2 2
3 13 1581.04 21 14.19 2320 691 2.70 / 1029.90 2 2
4 13 1035.40 21 14.39 1660 502 3.20 / 1030.40 2 2
5 13 332.12 21 14.71 789 244 3.44 / 1030.64 2 2
6 8 0.16 170 14.84 346 873 4.31 / 1031.52 2 3
Average= 4.39
(KJ/cycle)

Cycle 233 GMT 16/ 2/2024 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 28 14.79 488 202 0.20 / 1023.00 2 2
2 7 2005.60 46 14.08 2825 1830 2.03 / 1024.83 2 2
3 13 1602.52 21 14.18 2345 698 2.73 / 1025.53 2 2
4 13 1042.12 21 14.38 1675 506 3.24 / 1026.04 2 2
5 13 466.76 21 14.64 962 296 3.53 / 1026.33 2 2
6 8 0.52 170 14.84 345 870 4.40 / 1027.20 2 5
Average= 4.39
(KJ/cycle)

Cycle 232 GMT 6/ 2/2024 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 14.79 485 201 0.20 / 1018.55 2 2
2 7 2002.16 45 14.08 2858 1811 2.01 / 1020.36 2 2
3 13 1732.76 21 14.14 2545 756 2.77 / 1021.12 2 2
4 13 1141.72 21 14.35 1787 539 3.31 / 1021.65 2 2
5 13 414.36 21 14.67 890 274 3.58 / 1021.93 2 2
6 8 0.04 170 14.84 345 870 4.45 / 1022.80 2 4
Average= 4.39
(KJ/cycle)

Cycle 231 GMT 27/ 1/2024 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 27 14.78 497 198 0.20 / 1014.16 2 2
2 3 1024.88 1 14.94 1742 26 0.22 / 1014.19 2 2
3 7 2005.12 46 14.07 2868 1856 2.08 / 1016.04 2 2
4 13 1478.32 21 14.23 2214 662 2.74 / 1016.71 2 2
5 13 1074.92 21 14.37 1707 515 3.26 / 1017.22 2 2
6 13 373.28 21 14.69 837 258 3.52 / 1017.48 2 2
7 8 0.20 170 14.84 345 870 4.39 / 1018.35 2 3
Average= 4.39
(KJ/cycle)

Cycle 230 GMT 17/ 1/2024 5:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 27 14.78 495 198 0.20 / 1009.65 2 2
2 7 2003.84 45 14.07 2878 1822 2.02 / 1011.47 2 2
3 13 1586.88 21 14.19 2365 705 2.72 / 1012.18 2 2
4 13 1028.12 21 14.39 1648 498 3.22 / 1012.68 2 2
5 13 453.00 21 14.64 941 289 3.51 / 1012.97 2 2
6 13 13.80 21 14.86 378 118 3.63 / 1013.08 2 2
7 8 -0.04 170 14.82 349 879 4.51 / 1013.96 2 5
Average= 4.39
(KJ/cycle)

Cycle 229 GMT 7/ 1/2024 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 27 14.78 504 201 0.20 / 1005.28 2 2
2 7 2006.88 45 14.07 2876 1821 2.02 / 1007.10 2 2
3 13 1596.28 21 14.17 2395 713 2.73 / 1007.81 2 2
4 13 1029.48 21 14.39 1653 500 3.23 / 1008.31 2 2
5 13 330.60 21 14.71 789 244 3.48 / 1008.56 2 2
6 8 -0.36 170 14.83 356 898 4.38 / 1009.45 2 2
Average= 4.39
(KJ/cycle)

Cycle 228 GMT 28/12/2023 6: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 27 14.78 495 198 0.20 / 1000.80 2 2
2 7 2003.64 45 14.08 2863 1814 2.01 / 1002.62 2 2
3 13 1725.72 21 14.15 2550 758 2.77 / 1003.37 2 2
4 13 1136.76 21 14.34 1792 540 3.31 / 1003.91 2 2
5 13 410.32 21 14.67 890 274 3.58 / 1004.19 2 2
6 8 -0.04 170 14.83 353 890 4.47 / 1005.08 2 2
Average= 4.39
(KJ/cycle)

Cycle 227 GMT 18/12/2023 6:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 27 14.78 488 195 0.19 / 996.44 2 2
2 7 2007.92 45 14.07 2891 1830 2.03 / 998.27 2 2
3 13 1602.12 21 14.17 2382 709 2.73 / 998.98 2 2
4 13 1037.04 21 14.39 1664 503 3.24 / 999.48 2 2
5 13 341.80 21 14.70 794 245 3.48 / 999.73 2 2
6 8 0.28 170 14.84 348 878 4.36 / 1000.61 2 3
Average= 4.39
(KJ/cycle)

Cycle 226 GMT 8/12/2023 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 27 14.78 502 200 0.20 / 992.05 2 2
2 7 2007.48 45 14.07 2894 1832 2.03 / 993.88 2 2
3 13 1596.56 21 14.19 2341 698 2.73 / 994.58 2 2
4 13 1036.76 21 14.39 1656 500 3.23 / 995.08 2 2
5 13 455.36 21 14.65 943 290 3.52 / 995.37 2 2
6 8 0.48 170 14.84 348 878 4.40 / 996.25 2 10
Average= 4.39
(KJ/cycle)

Cycle 225 GMT 28/11/2023 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 26 14.78 496 191 0.19 / 987.67 2 2
2 3 1041.28 1 14.87 1782 26 0.22 / 987.70 2 2
3 7 2003.36 45 14.07 2886 1827 2.04 / 989.52 2 2
4 13 1597.72 21 14.18 2361 703 2.75 / 990.23 2 2
5 13 1028.60 21 14.40 1655 500 3.25 / 990.73 2 2
6 13 333.88 21 14.71 789 244 3.49 / 990.97 2 2
7 8 -0.12 170 14.84 347 875 4.37 / 991.85 2 3
Average= 4.39
(KJ/cycle)

Cycle 224 GMT 18/11/2023 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 28 14.77 488 202 0.20 / 983.31 2 2
2 3 939.36 -1 15.29 0 0 0.00 / 983.31 2 2
3 3 971.52 -1 15.32 0 0 0.00 / 983.31 2 2
4 7 2008.64 45 14.08 2859 1811 2.01 / 985.12 2 2
5 13 1484.28 21 14.23 2199 657 2.67 / 985.78 2 2
6 13 1077.64 21 14.37 1698 512 3.18 / 986.29 2 2
7 13 494.80 21 14.63 989 304 3.49 / 986.60 2 2
8 8 0.36 170 14.83 350 882 4.37 / 987.48 2 3
Average= 4.39
(KJ/cycle)

Cycle 223 GMT 8/11/2023 6:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 26 14.78 500 192 0.19 / 978.68 2 2
2 3 1070.60 2 14.75 1810 53 0.25 / 978.74 2 2
3 7 2007.32 46 14.07 2879 1863 2.11 / 980.60 2 2
4 13 1595.96 21 14.18 2377 708 2.82 / 981.31 2 2
5 13 1020.16 21 14.39 1631 493 3.31 / 981.80 2 2
6 13 458.60 21 14.65 947 291 3.60 / 982.09 2 2
7 13 66.96 21 14.83 449 140 3.74 / 982.23 2 2
8 8 -0.08 170 14.83 348 877 4.62 / 983.11 2 5
Average= 4.39
(KJ/cycle)

Cycle 222 GMT 29/10/2023 7: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 26 14.78 489 188 0.19 / 974.29 2 2
2 7 2003.04 45 14.09 2877 1824 2.01 / 976.11 2 2
3 13 1592.80 21 14.19 2366 705 2.72 / 976.82 2 2
4 13 1028.96 21 14.39 1651 499 3.22 / 977.32 2 2
5 13 457.20 21 14.65 946 291 3.51 / 977.61 2 2
6 8 0.28 170 14.84 350 883 4.39 / 978.49 2 2
Average= 4.39
(KJ/cycle)

Cycle 221 GMT 19/10/2023 7:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 27 14.77 505 201 0.20 / 969.84 2 2
2 7 2005.36 46 14.08 2878 1864 2.07 / 971.70 2 2
3 13 1601.68 21 14.18 2403 716 2.78 / 972.42 2 2
4 13 1046.80 21 14.39 1684 509 3.29 / 972.93 2 2
5 13 463.76 21 14.65 954 293 3.58 / 973.22 2 2
6 8 0.40 170 14.84 349 880 4.46 / 974.10 2 5
Average= 4.39
(KJ/cycle)

Cycle 220 GMT 9/10/2023 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 26 14.78 492 189 0.19 / 965.33 2 2
2 7 2005.52 45 14.08 2879 1824 2.01 / 967.15 2 2
3 13 1728.92 21 14.15 2533 753 2.77 / 967.90 2 2
4 13 1007.68 21 14.41 1623 491 3.26 / 968.39 2 2
5 13 313.80 21 14.72 762 236 3.49 / 968.63 2 2
6 13 38.52 21 14.86 409 128 3.62 / 968.76 2 2
7 8 0.32 170 14.83 350 882 4.50 / 969.64 2 7
Average= 4.39
(KJ/cycle)

Cycle 219 GMT 29/ 9/2023 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 26 14.78 489 188 0.19 / 960.78 2 2
2 7 2005.48 46 14.08 2867 1857 2.04 / 962.64 2 2
3 13 1597.64 21 14.20 2335 696 2.74 / 963.34 2 2
4 13 1042.28 21 14.40 1654 500 3.24 / 963.84 2 2
5 13 470.80 21 14.65 950 292 3.53 / 964.13 2 2
6 13 18.24 21 14.87 377 118 3.65 / 964.25 2 2
7 8 -0.20 170 14.83 353 890 4.54 / 965.14 2 2
Average= 4.39
(KJ/cycle)

Cycle 218 GMT 19/ 9/2023 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 26 14.78 490 188 0.19 / 956.46 2 2
2 7 2008.16 45 14.08 2861 1813 2.00 / 958.28 2 2
3 13 1601.88 21 14.19 2363 704 2.71 / 958.98 2 2
4 13 1042.24 21 14.39 1670 505 3.21 / 959.49 2 2
5 13 325.88 21 14.72 771 238 3.45 / 959.72 2 2
6 8 0.48 170 14.84 345 870 4.32 / 960.59 2 3
Average= 4.39
(KJ/cycle)

Cycle 217 GMT 9/ 9/2023 8: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 26 14.77 497 191 0.19 / 952.08 2 2
2 7 2001.72 45 14.11 2822 1792 1.98 / 953.88 2 2
3 13 1590.72 21 14.20 2346 700 2.68 / 954.58 2 2
4 13 1152.00 21 14.34 1801 542 3.22 / 955.12 2 2
5 13 420.08 21 14.67 895 276 3.50 / 955.39 2 2
6 8 0.20 170 14.84 350 883 4.38 / 956.28 2 4
Average= 4.39
(KJ/cycle)

Cycle 216 GMT 30/ 8/2023 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 26 14.79 488 188 0.19 / 947.62 2 2
2 7 2008.32 45 14.08 2878 1824 2.01 / 949.45 2 2
3 13 1591.72 21 14.19 2370 706 2.72 / 950.15 2 2
4 13 1024.40 21 14.41 1627 492 3.21 / 950.64 2 2
5 13 322.72 21 14.72 770 238 3.45 / 950.88 2 2
6 13 37.60 21 14.86 409 128 3.58 / 951.01 2 2
7 8 -0.04 170 14.83 350 882 4.46 / 951.89 2 3
Average= 4.39
(KJ/cycle)

Cycle 215 GMT 20/ 8/2023 8:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 26 14.78 494 190 0.19 / 943.25 2 2
2 7 2006.32 45 14.09 2891 1833 2.02 / 945.09 2 2
3 13 1726.36 21 14.16 2528 752 2.77 / 945.84 2 2
4 13 1002.36 21 14.42 1613 488 3.26 / 946.33 2 2
5 13 299.48 21 14.74 740 229 3.49 / 946.56 2 2
6 8 -0.12 170 14.85 348 879 4.37 / 947.44 2 3
Average= 4.39
(KJ/cycle)

Cycle 214 GMT 10/ 8/2023 8:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 27 14.78 508 203 0.20 / 938.84 2 2
2 3 971.20 -1 15.31 0 0 0.00 / 938.84 2 2
3 7 2003.36 45 14.09 2872 1821 2.02 / 940.67 2 2
4 13 1598.04 21 14.20 2342 698 2.72 / 941.36 2 2
5 13 1164.44 21 14.34 1808 544 3.27 / 941.91 2 2
6 13 424.12 21 14.68 901 278 3.54 / 942.19 2 2
7 8 0.20 170 14.85 348 879 4.42 / 943.06 2 4
Average= 4.39
(KJ/cycle)

Cycle 213 GMT 31/ 7/2023 8:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 25 14.79 505 187 0.19 / 934.37 2 2
2 10 1002.92 3 14.66 1676 74 0.26 / 934.44 2 2
3 7 2007.28 45 14.09 2882 1827 2.09 / 936.27 2 2
4 13 1597.40 21 14.19 2379 709 2.80 / 936.98 2 2
5 13 1024.92 21 14.41 1656 501 3.30 / 937.48 2 2
6 13 443.40 21 14.67 928 286 3.58 / 937.76 2 2
7 8 0.00 170 14.85 348 879 4.46 / 938.64 2 2
Average= 4.39
(KJ/cycle)

Cycle 212 GMT 21/ 7/2023 9:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 27 14.78 493 197 0.20 / 929.95 2 2
2 3 907.28 -2 15.31 0 0 0.00 / 929.95 2 2
3 7 2006.80 45 14.11 2848 1808 2.01 / 931.76 2 2
4 13 1594.72 21 14.20 2377 709 2.71 / 932.47 2 2
5 13 1165.48 21 14.34 1833 552 3.27 / 933.02 2 2
6 13 437.16 21 14.67 920 283 3.55 / 933.30 2 2
7 8 0.28 170 14.85 348 879 4.43 / 934.18 2 3
Average= 4.39
(KJ/cycle)

Cycle 211 GMT 11/ 7/2023 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 27 14.78 504 201 0.20 / 925.09 2 2
2 3 1019.04 1 14.98 1759 26 0.23 / 925.11 2 2
3 7 2003.80 45 14.12 2843 1806 2.03 / 926.92 2 2
4 13 1721.36 21 14.19 2482 740 2.77 / 927.66 2 2
5 13 1134.52 21 14.37 1779 537 3.31 / 928.20 2 2
6 13 553.56 21 14.62 1059 325 3.64 / 928.52 2 2
7 8 0.72 170 14.85 347 876 4.51 / 929.40 2 2
8 14 0.72 70 14.82 341 354 4.87 / 929.75 2 5
Average= 4.39
(KJ/cycle)

Cycle 210 GMT 1/ 7/2023 9:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 27 14.80 499 199 0.20 / 920.49 2 2
2 7 2003.00 45 14.11 2853 1812 2.01 / 922.30 2 2
3 13 1733.52 21 14.18 2522 751 2.76 / 923.06 2 2
4 13 1156.44 21 14.36 1796 542 3.30 / 923.60 2 2
5 13 461.68 21 14.67 943 291 3.59 / 923.89 2 2
6 13 36.48 21 14.87 403 126 3.72 / 924.01 2 2
7 8 0.08 170 14.84 346 873 4.59 / 924.89 2 13
Average= 4.38
(KJ/cycle)

Cycle 209 GMT 21/ 6/2023 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 27 14.80 496 198 0.20 / 916.08 2 2
2 7 2004.20 45 14.09 2887 1831 2.03 / 917.92 2 2
3 13 1604.44 21 14.19 2380 709 2.74 / 918.62 2 2
4 13 1036.12 21 14.40 1659 502 3.24 / 919.13 2 2
5 13 461.64 21 14.66 947 292 3.53 / 919.42 2 2
6 8 -0.40 170 14.85 347 876 4.41 / 920.29 2 3
Average= 4.38
(KJ/cycle)

Cycle 208 GMT 11/ 6/2023 10:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 27 14.80 491 196 0.20 / 911.74 2 2
2 7 2003.16 45 14.12 2813 1787 1.98 / 913.52 2 2
3 13 1732.68 21 14.18 2508 747 2.73 / 914.27 2 2
4 13 1019.76 21 14.42 1643 498 3.23 / 914.77 2 2
5 13 331.24 21 14.73 780 241 3.47 / 915.01 2 2
6 8 0.68 170 14.86 347 877 4.35 / 915.89 2 2
Average= 4.38
(KJ/cycle)

Cycle 207 GMT 1/ 6/2023 10:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 26 14.80 494 190 0.19 / 907.34 2 2
2 3 1023.52 1 14.98 1760 26 0.22 / 907.37 2 2
3 7 2007.84 45 14.10 2890 1834 2.05 / 909.20 2 2
4 13 1601.88 21 14.20 2375 708 2.76 / 909.91 2 2
5 13 1038.80 21 14.40 1663 503 3.26 / 910.42 2 2
6 13 347.32 21 14.72 803 248 3.51 / 910.66 2 2
7 8 -0.32 170 14.86 347 877 4.39 / 911.54 2 3
Average= 4.38
(KJ/cycle)

Cycle 206 GMT 22/ 5/2023 10:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 26 14.81 490 189 0.19 / 902.83 2 2
2 7 2007.52 45 14.10 2866 1818 2.01 / 904.65 2 2
3 13 1595.80 21 14.21 2350 701 2.71 / 905.35 2 2
4 13 1167.88 21 14.35 1813 546 3.25 / 905.90 2 2
5 13 308.88 21 14.75 750 232 3.49 / 906.13 2 2
6 13 42.76 21 14.88 411 128 3.62 / 906.26 2 2
7 8 0.36 170 14.85 354 894 4.51 / 907.15 2 4
Average= 4.38
(KJ/cycle)

Cycle 205 GMT 12/ 5/2023 10:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 27 14.80 487 195 0.19 / 898.52 2 2
2 7 2004.68 45 14.11 2843 1805 2.00 / 900.32 2 2
3 13 1599.04 21 14.21 2385 712 2.71 / 901.04 2 2
4 13 1048.60 21 14.41 1656 501 3.21 / 901.54 2 2
5 13 350.40 21 14.73 800 247 3.46 / 901.78 2 2
6 8 0.40 170 14.86 341 861 4.32 / 902.65 2 4
Average= 4.38
(KJ/cycle)

Cycle 204 GMT 2/ 5/2023 10:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.82 484 201 0.20 / 894.08 2 2
2 3 967.40 -1 15.32 0 0 0.00 / 894.08 2 2
3 7 2005.76 45 14.10 2889 1833 2.03 / 895.91 2 2
4 13 1471.08 21 14.25 2195 657 2.69 / 896.57 2 2
5 13 1042.64 21 14.40 1663 503 3.19 / 897.07 2 2
6 13 320.64 21 14.74 771 239 3.43 / 897.31 2 2
7 13 90.44 21 14.85 473 148 3.58 / 897.46 2 2
8 8 0.20 170 14.85 343 866 4.45 / 898.32 2 3
Average= 4.38
(KJ/cycle)

Cycle 203 GMT 22/ 4/2023 10:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 27 14.82 489 196 0.20 / 889.70 2 2
2 7 2002.96 45 14.10 2868 1820 2.02 / 891.52 2 2
3 13 1595.32 21 14.21 2359 704 2.72 / 892.23 2 2
4 13 1023.72 21 14.43 1642 498 3.22 / 892.73 2 2
5 13 445.68 21 14.68 929 286 3.50 / 893.01 2 2
6 8 -0.16 170 14.86 343 866 4.37 / 893.88 2 4
Average= 4.38
(KJ/cycle)

Cycle 202 GMT 12/ 4/2023 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 28 14.82 481 200 0.20 / 885.33 2 2
2 7 2005.00 45 14.10 2877 1825 2.03 / 887.15 2 2
3 13 1734.04 21 14.17 2533 754 2.78 / 887.91 2 2
4 13 887.68 21 14.49 1469 447 3.23 / 888.35 2 2
5 13 467.12 21 14.67 952 293 3.52 / 888.65 2 2
6 8 0.52 170 14.87 341 862 4.38 / 889.51 2 3
Average= 4.38
(KJ/cycle)

Cycle 201 GMT 2/ 4/2023 11:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 27 14.82 481 192 0.19 / 880.93 2 2
2 3 1044.36 1 14.88 1752 26 0.22 / 880.95 2 2
3 7 2003.24 45 14.10 2880 1827 2.05 / 882.78 2 2
4 13 1732.32 21 14.18 2528 753 2.80 / 883.53 2 2
5 13 1008.04 21 14.43 1625 492 3.29 / 884.03 2 2
6 13 312.24 21 14.75 755 234 3.52 / 884.26 2 2
7 8 0.04 170 14.87 343 867 4.39 / 885.13 2 7
Average= 4.38
(KJ/cycle)

Cycle 200 GMT 23/ 3/2023 11:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 26 14.82 485 187 0.19 / 876.53 2 2
2 7 2003.32 46 14.11 2831 1837 2.02 / 878.37 2 2
3 13 1601.56 21 14.21 2358 704 2.73 / 879.07 2 2
4 13 1057.84 21 14.41 1673 506 3.23 / 879.58 2 2
5 13 493.00 21 14.66 984 303 3.54 / 879.88 2 2
6 8 0.28 170 14.87 338 854 4.39 / 880.74 2 3
Average= 4.38
(KJ/cycle)

Cycle 199 GMT 13/ 3/2023 11:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 27 14.81 472 189 0.19 / 872.25 2 2
2 3 967.20 -1 15.32 0 0 0.00 / 872.25 2 2
3 7 2008.48 45 14.12 2836 1802 1.99 / 874.05 2 2
4 13 1587.48 21 14.22 2343 700 2.69 / 874.75 2 2
5 13 1026.80 21 14.42 1642 497 3.19 / 875.25 2 2
6 13 319.36 21 14.74 763 236 3.42 / 875.49 2 2
7 8 0.04 170 14.87 339 857 4.28 / 876.34 2 5
Average= 4.38
(KJ/cycle)

Cycle 198 GMT 3/ 3/2023 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 28 14.81 484 201 0.20 / 867.58 2 2
2 7 2005.80 45 14.11 2888 1834 2.03 / 869.42 2 2
3 13 1587.60 21 14.22 2358 704 2.74 / 870.12 2 2
4 13 1019.88 21 14.43 1629 494 3.23 / 870.61 2 2
5 13 314.68 21 14.75 759 235 3.47 / 870.85 2 2
6 8 -0.04 170 14.87 341 862 4.33 / 871.71 2 2
7 14 -0.04 70 14.84 338 351 4.68 / 872.06 2 9
Average= 4.38
(KJ/cycle)

Cycle 197 GMT 21/ 2/2023 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 27 14.82 478 191 0.19 / 863.08 2 2
2 3 1024.12 1 14.98 1738 26 0.22 / 863.11 2 2
3 7 2005.72 45 14.10 2891 1834 2.05 / 864.94 2 2
4 13 1607.40 21 14.22 2365 706 2.76 / 865.65 2 2
5 13 1036.92 21 14.41 1656 501 3.26 / 866.15 2 2
6 13 326.36 21 14.74 770 238 3.50 / 866.39 2 2
7 13 21.76 21 14.90 382 120 3.62 / 866.51 2 2
8 8 0.16 170 14.86 347 877 4.49 / 867.38 2 2
Average= 4.38
(KJ/cycle)

Cycle 196 GMT 11/ 2/2023 11:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 27 14.83 469 188 0.19 / 858.62 2 2
2 7 2004.48 45 14.12 2831 1799 1.99 / 860.41 2 2
3 13 1596.16 21 14.22 2326 695 2.68 / 861.11 2 2
4 13 1042.64 21 14.41 1672 506 3.19 / 861.62 2 2
5 13 461.88 21 14.67 951 293 3.48 / 861.91 2 2
6 13 35.64 21 14.89 398 124 3.60 / 862.03 2 2
7 8 -0.12 170 14.86 339 856 4.46 / 862.89 2 4
Average= 4.38
(KJ/cycle)

Cycle 195 GMT 1/ 2/2023 11:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 27 14.81 476 190 0.19 / 854.21 2 2
2 7 2005.32 45 14.12 2858 1816 2.01 / 856.02 2 2
3 13 1740.80 21 14.18 2540 756 2.76 / 856.78 2 2
4 13 1024.88 21 14.43 1645 498 3.26 / 857.28 2 2
5 13 450.92 21 14.68 933 288 3.55 / 857.57 2 2
6 8 0.32 170 14.87 341 862 4.41 / 858.43 2 3
Average= 4.38
(KJ/cycle)

Cycle 194 GMT 22/ 1/2023 11:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 27 14.82 479 192 0.19 / 849.77 2 2
2 7 2003.48 46 14.12 2871 1865 2.06 / 851.64 2 2
3 13 1467.24 21 14.26 2197 658 2.71 / 852.30 2 2
4 13 1042.52 21 14.41 1662 503 3.22 / 852.80 2 2
5 13 326.72 21 14.74 773 239 3.46 / 853.04 2 2
6 13 17.80 21 14.90 374 117 3.57 / 853.16 2 2
7 8 -0.12 170 14.86 341 861 4.44 / 854.02 2 2
Average= 4.38
(KJ/cycle)

Cycle 193 GMT 12/ 1/2023 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 14.82 485 194 0.19 / 845.28 2 2
2 7 2002.48 45 14.12 2842 1806 2.00 / 847.09 2 2
3 13 1593.24 21 14.23 2357 704 2.70 / 847.79 2 2
4 13 1151.36 21 14.38 1784 539 3.24 / 848.33 2 2
5 13 432.44 21 14.70 903 279 3.52 / 848.61 2 2
6 13 14.44 21 14.91 367 115 3.64 / 848.73 2 2
7 8 0.40 170 14.87 339 857 4.49 / 849.58 2 5
Average= 4.38
(KJ/cycle)

Cycle 192 GMT 2/ 1/2023 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 27 14.83 469 188 0.19 / 840.95 2 2
2 7 2003.92 45 14.11 2880 1829 2.02 / 842.78 2 2
3 13 1596.80 21 14.22 2359 704 2.72 / 843.48 2 2
4 13 1027.68 21 14.43 1638 496 3.22 / 843.98 2 2
5 13 327.40 21 14.75 776 240 3.46 / 844.22 2 2
6 8 0.00 170 14.87 343 867 4.32 / 845.09 2 3
Average= 4.38
(KJ/cycle)

Cycle 191 GMT 23/12/2022 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 26 14.82 481 185 0.19 / 836.51 2 2
2 3 1054.40 1 14.85 1758 26 0.21 / 836.53 2 2
3 7 2002.72 46 14.12 2864 1860 2.07 / 838.39 2 2
4 13 1600.24 21 14.23 2345 701 2.77 / 839.09 2 2
5 13 1050.64 21 14.42 1675 507 3.28 / 839.60 2 2
6 13 471.32 21 14.68 957 295 3.57 / 839.90 2 2
7 8 0.32 170 14.87 343 867 4.44 / 840.76 2 7
Average= 4.38
(KJ/cycle)

Cycle 190 GMT 13/12/2022 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 26 14.82 477 184 0.18 / 832.04 2 2
2 7 2005.12 45 14.12 2900 1843 2.03 / 833.88 2 2
3 13 1725.96 21 14.19 2530 754 2.78 / 834.64 2 2
4 13 1156.96 21 14.38 1797 543 3.32 / 835.18 2 2
5 13 433.64 21 14.70 909 281 3.60 / 835.46 2 2
6 8 0.12 170 14.88 340 860 4.46 / 836.32 2 3
Average= 4.38
(KJ/cycle)

Cycle 189 GMT 3/12/2022 12:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 26 14.81 490 189 0.19 / 827.28 2 2
2 7 2004.12 45 14.12 2884 1832 2.02 / 829.11 2 2
3 13 1734.72 21 14.19 2545 758 2.78 / 829.87 2 2
4 13 1001.96 21 14.45 1623 492 3.27 / 830.36 2 2
5 13 440.80 21 14.69 921 284 3.56 / 830.64 2 2
6 8 0.24 170 14.87 342 865 4.42 / 831.51 2 3
7 14 0.24 70 14.84 338 351 4.77 / 831.86 2 4
Average= 4.38
(KJ/cycle)

Cycle 188 GMT 23/11/2022 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 14.81 483 193 0.19 / 822.38 2 2
2 3 962.64 -1 15.34 0 0 0.00 / 822.38 2 2
3 7 2004.12 45 14.13 2830 1799 1.99 / 824.18 2 2
4 13 1734.52 21 14.19 2531 754 2.75 / 824.93 2 2
5 13 1152.68 21 14.38 1786 539 3.29 / 825.47 2 2
6 13 426.48 21 14.70 902 278 3.56 / 825.75 2 2
7 13 18.88 21 14.91 380 119 3.68 / 825.87 2 2
8 8 -0.04 170 14.87 343 867 4.55 / 826.74 2 4
9 14 -0.04 70 14.84 337 350 4.90 / 827.09 2 8
Average= 4.38
(KJ/cycle)

Cycle 187 GMT 13/11/2022 12:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 27 14.82 479 192 0.19 / 817.84 2 2
2 3 1024.60 1 15.00 1732 26 0.22 / 817.87 2 2
3 7 2006.76 45 14.13 2843 1808 2.03 / 819.68 2 2
4 13 1727.72 21 14.19 2521 751 2.78 / 820.43 2 2
5 13 1015.04 21 14.45 1619 491 3.27 / 820.92 2 2
6 13 448.48 21 14.70 926 286 3.55 / 821.20 2 2
7 13 14.04 21 14.91 372 116 3.67 / 821.32 2 2
8 8 -0.16 170 14.87 342 865 4.53 / 822.19 2 4
Average= 4.37
(KJ/cycle)

Cycle 186 GMT 3/11/2022 13: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 27 14.82 484 194 0.19 / 813.54 2 2
2 7 2002.36 45 14.14 2838 1806 2.00 / 815.34 2 2
3 13 1606.08 21 14.23 2379 711 2.71 / 816.05 2 2
4 13 1041.60 21 14.43 1649 500 3.21 / 816.55 2 2
5 13 344.28 21 14.75 784 243 3.45 / 816.80 2 2
6 8 0.20 170 14.88 338 855 4.31 / 817.65 2 6
Average= 4.37
(KJ/cycle)

Cycle 185 GMT 24/10/2022 13: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 26 14.82 495 191 0.19 / 809.23 2 2
2 3 1037.88 1 14.95 1770 26 0.22 / 809.25 2 2
3 7 2003.40 45 14.12 2894 1839 2.06 / 811.09 2 2
4 13 1590.60 21 14.23 2360 705 2.76 / 811.80 2 2
5 13 1030.12 21 14.43 1637 496 3.26 / 812.29 2 2
6 13 195.12 21 14.83 604 188 3.45 / 812.48 2 2
7 8 -0.08 170 14.88 341 863 4.31 / 813.34 2 2
Average= 4.37
(KJ/cycle)

Cycle 184 GMT 14/10/2022 13: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 26 14.81 494 190 0.19 / 804.83 2 2
2 7 2003.36 45 14.13 2844 1808 2.00 / 806.63 2 2
3 13 1724.08 21 14.19 2530 754 2.75 / 807.39 2 2
4 13 1013.24 21 14.45 1619 491 3.24 / 807.88 2 2
5 13 452.76 21 14.69 935 288 3.53 / 808.17 2 2
6 8 0.04 170 14.88 343 868 4.40 / 809.04 2 3
Average= 4.37
(KJ/cycle)

Cycle 183 GMT 4/10/2022 13:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 26 14.82 487 188 0.19 / 800.36 2 2
2 7 2005.20 45 14.13 2851 1813 2.00 / 802.17 2 2
3 13 1596.32 21 14.24 2326 696 2.70 / 802.86 2 2
4 13 1036.48 21 14.43 1657 502 3.20 / 803.37 2 2
5 13 453.64 21 14.69 930 287 3.49 / 803.65 2 2
6 13 12.56 21 14.91 367 115 3.60 / 803.77 2 2
7 8 -0.16 170 14.87 343 867 4.47 / 804.64 2 2
Average= 4.37
(KJ/cycle)

Cycle 182 GMT 24/ 9/2022 13:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 27 14.80 494 197 0.20 / 795.92 2 2
2 3 947.88 -1 15.34 0 0 0.00 / 795.92 2 2
3 7 2002.64 45 14.13 2864 1821 2.02 / 797.74 2 2
4 13 1724.52 21 14.19 2545 758 2.78 / 798.50 2 2
5 13 1131.24 21 14.40 1766 534 3.31 / 799.03 2 2
6 13 413.80 21 14.72 882 273 3.58 / 799.30 2 2
7 8 0.20 170 14.88 342 865 4.45 / 800.17 2 4
Average= 4.37
(KJ/cycle)

Cycle 181 GMT 14/ 9/2022 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 26 14.82 501 193 0.19 / 791.17 2 2
2 3 1045.80 1 14.91 1791 27 0.22 / 791.19 2 2
3 7 2002.48 45 14.13 2861 1819 2.04 / 793.01 2 2
4 13 1593.56 21 14.24 2347 702 2.74 / 793.71 2 2
5 13 1026.92 21 14.44 1641 498 3.24 / 794.21 2 2
6 13 468.40 21 14.69 952 294 3.53 / 794.50 2 2
7 8 -0.20 170 14.88 341 863 4.39 / 795.37 2 3
8 14 -0.20 70 14.85 339 352 4.75 / 795.72 2 3
Average= 4.37
(KJ/cycle)

Cycle 180 GMT 4/ 9/2022 13:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 27 14.82 485 194 0.19 / 786.82 2 2
2 3 965.60 -1 15.35 0 0 0.00 / 786.82 2 2
3 7 2007.52 45 14.14 2844 1810 2.00 / 788.63 2 2
4 13 1602.36 21 14.23 2383 712 2.72 / 789.35 2 2
5 13 1042.48 21 14.43 1669 506 3.22 / 789.85 2 2
6 13 343.12 21 14.75 797 247 3.47 / 790.10 2 2
7 8 0.00 170 14.87 346 875 4.34 / 790.97 2 4
Average= 4.37
(KJ/cycle)

Cycle 179 GMT 25/ 8/2022 13:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 26 14.82 494 190 0.19 / 782.17 2 2
2 3 1053.60 1 14.88 1768 26 0.22 / 782.20 2 2
3 7 2002.80 45 14.15 2824 1798 2.01 / 784.00 2 2
4 13 1732.00 21 14.20 2527 754 2.77 / 784.75 2 2
5 13 1135.32 21 14.40 1779 538 3.31 / 785.29 2 2
6 13 535.00 21 14.65 1036 319 3.63 / 785.61 2 2
7 13 107.04 21 14.86 493 154 3.78 / 785.76 2 2
8 8 0.88 170 14.86 344 869 4.65 / 786.63 2 3
Average= 4.37
(KJ/cycle)

Cycle 178 GMT 15/ 8/2022 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 27 14.82 483 193 0.19 / 777.86 2 2
2 3 951.28 -1 15.35 0 0 0.00 / 777.86 2 2
3 7 2002.24 45 14.14 2862 1821 2.01 / 779.68 2 2
4 13 1590.04 21 14.25 2345 702 2.72 / 780.38 2 2
5 13 1024.84 21 14.44 1643 498 3.21 / 780.88 2 2
6 13 329.68 21 14.76 772 239 3.45 / 781.12 2 2
7 8 0.12 170 14.88 342 865 4.32 / 781.98 2 3
Average= 4.37
(KJ/cycle)

Cycle 177 GMT 5/ 8/2022 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 14.83 485 194 0.19 / 773.52 2 2
2 3 1028.68 1 14.98 1779 27 0.22 / 773.55 2 2
3 7 2002.96 45 14.14 2861 1820 2.04 / 775.37 2 2
4 13 1484.24 21 14.27 2231 669 2.71 / 776.04 2 2
5 13 1057.64 21 14.42 1686 511 3.22 / 776.55 2 2
6 13 347.28 21 14.75 799 247 3.47 / 776.80 2 2
7 8 -0.24 170 14.88 343 868 4.34 / 777.66 2 4
Average= 4.37
(KJ/cycle)

Cycle 176 GMT 26/ 7/2022 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 27 14.82 497 199 0.20 / 769.15 2 2
2 7 2004.20 45 14.14 2851 1814 2.01 / 770.97 2 2
3 13 1729.96 21 14.20 2523 752 2.77 / 771.72 2 2
4 13 1017.64 21 14.44 1641 498 3.26 / 772.22 2 2
5 13 315.40 21 14.77 761 236 3.50 / 772.45 2 2
6 8 0.60 170 14.88 345 873 4.37 / 773.33 2 4
Average= 4.37
(KJ/cycle)

Cycle 175 GMT 16/ 7/2022 14:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 26 14.82 504 194 0.19 / 764.75 2 2
2 3 1032.24 1 14.96 1753 26 0.22 / 764.78 2 2
3 7 2007.72 45 14.15 2843 1810 2.03 / 766.59 2 2
4 13 1606.40 21 14.24 2399 717 2.75 / 767.31 2 2
5 13 1045.52 21 14.43 1676 508 3.26 / 767.81 2 2
6 13 346.48 21 14.75 804 249 3.51 / 768.06 2 2
7 8 0.04 170 14.88 353 893 4.40 / 768.96 2 4
Average= 4.37
(KJ/cycle)

Cycle 174 GMT 6/ 7/2022 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 27 14.83 482 193 0.19 / 760.41 2 2
2 7 2006.84 45 14.14 2848 1812 2.01 / 762.22 2 2
3 13 1592.44 21 14.25 2376 711 2.72 / 762.93 2 2
4 13 1025.56 21 14.45 1645 499 3.22 / 763.43 2 2
5 13 324.88 21 14.77 771 239 3.45 / 763.67 2 2
6 8 0.16 170 14.88 351 888 4.34 / 764.56 2 2
Average= 4.37
(KJ/cycle)

Cycle 173 GMT 26/ 6/2022 14:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 28 14.82 479 199 0.20 / 756.04 2 2
2 3 968.84 -1 15.35 0 0 0.00 / 756.04 2 2
3 7 2004.76 45 14.15 2852 1816 2.01 / 757.85 2 2
4 13 1602.44 21 14.25 2365 708 2.72 / 758.56 2 2
5 13 1045.36 21 14.43 1658 502 3.22 / 759.06 2 2
6 13 468.20 21 14.69 951 293 3.52 / 759.36 2 2
7 8 -0.16 170 14.88 340 860 4.38 / 760.22 2 8
Average= 4.37
(KJ/cycle)

Cycle 172 GMT 16/ 6/2022 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 27 14.84 492 197 0.20 / 751.73 2 2
2 3 1041.64 1 14.94 1775 27 0.22 / 751.76 2 2
3 7 2005.12 45 14.14 2871 1827 2.05 / 753.59 2 2
4 13 1477.56 21 14.28 2203 661 2.71 / 754.25 2 2
5 13 936.56 21 14.48 1524 463 3.17 / 754.71 2 2
6 13 376.16 21 14.73 839 260 3.43 / 754.97 2 2
7 8 0.60 170 14.88 343 868 4.30 / 755.84 2 8
Average= 4.37
(KJ/cycle)

Cycle 171 GMT 6/ 6/2022 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 27 14.83 482 193 0.19 / 747.39 2 2
2 7 2005.24 45 14.15 2816 1793 1.99 / 749.18 2 2
3 13 1598.96 21 14.25 2369 709 2.70 / 749.89 2 2
4 13 1034.92 21 14.44 1635 496 3.19 / 750.39 2 2
5 13 456.12 21 14.70 935 289 3.48 / 750.68 2 2
6 8 -0.20 170 14.89 339 858 4.34 / 751.54 2 4
Average= 4.37
(KJ/cycle)

Cycle 170 GMT 27/ 5/2022 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 14.84 482 200 0.20 / 743.02 2 2
2 3 962.84 -1 15.35 0 0 0.00 / 743.02 2 2
3 7 2007.72 45 14.13 2883 1833 2.03 / 744.86 2 2
4 13 1594.04 21 14.26 2327 697 2.73 / 745.55 2 2
5 13 1030.52 21 14.45 1640 498 3.23 / 746.05 2 2
6 13 460.04 21 14.70 938 290 3.52 / 746.34 2 2
7 8 0.72 170 14.89 338 856 4.37 / 747.20 2 2
Average= 4.37
(KJ/cycle)

Cycle 169 GMT 17/ 5/2022 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 27 14.84 484 194 0.19 / 738.65 2 2
2 7 2005.56 45 14.15 2827 1800 1.99 / 740.45 2 2
3 13 1597.36 21 14.25 2342 701 2.69 / 741.15 2 2
4 13 1163.24 21 14.39 1786 540 3.23 / 741.69 2 2
5 13 436.08 21 14.71 909 281 3.52 / 741.97 2 2
6 8 0.28 170 14.89 337 853 4.37 / 742.82 2 4
Average= 4.37
(KJ/cycle)

Cycle 168 GMT 7/ 5/2022 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 14.84 483 201 0.20 / 734.33 2 2
2 7 2004.08 45 14.15 2863 1823 2.02 / 736.15 2 2
3 13 1598.56 21 14.26 2348 703 2.73 / 736.86 2 2
4 13 1039.64 21 14.44 1652 501 3.23 / 737.36 2 2
5 13 335.76 21 14.76 784 243 3.47 / 737.60 2 2
6 8 0.16 170 14.89 338 856 4.33 / 738.46 2 2
Average= 4.37
(KJ/cycle)

Cycle 167 GMT 27/ 4/2022 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 27 14.84 473 190 0.19 / 729.97 2 2
2 7 2005.76 45 14.14 2856 1817 2.01 / 731.79 2 2
3 13 1601.28 21 14.24 2387 714 2.72 / 732.50 2 2
4 13 1041.36 21 14.44 1663 504 3.22 / 733.01 2 2
5 13 340.12 21 14.76 792 245 3.47 / 733.25 2 2
6 8 0.24 170 14.89 347 878 4.35 / 734.13 2 5
Average= 4.37
(KJ/cycle)

Cycle 166 GMT 17/ 4/2022 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 27 14.85 473 190 0.19 / 725.48 2 2
2 7 2003.64 45 14.14 2862 1821 2.01 / 727.30 2 2
3 13 1725.08 21 14.22 2501 747 2.76 / 728.05 2 2
4 13 992.12 21 14.47 1592 484 3.24 / 728.53 2 2
5 13 430.52 21 14.72 904 279 3.52 / 728.81 2 2
6 13 27.00 21 14.92 379 119 3.64 / 728.93 2 2
7 8 0.28 170 14.89 335 848 4.49 / 729.78 2 2
Average= 4.37
(KJ/cycle)

Cycle 165 GMT 7/ 4/2022 16: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 27 14.85 487 195 0.20 / 721.08 2 2
2 7 2003.24 45 14.14 2887 1837 2.03 / 722.92 2 2
3 13 1725.56 21 14.22 2495 745 2.78 / 723.67 2 2
4 13 1020.08 21 14.45 1628 494 3.27 / 724.16 2 2
5 13 448.12 21 14.71 921 285 3.56 / 724.44 2 2
6 8 -0.04 170 14.90 335 849 4.40 / 725.29 2 2
Average= 4.37
(KJ/cycle)

Cycle 164 GMT 28/ 3/2022 16:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.85 473 197 0.20 / 716.58 2 2
2 3 966.00 -1 15.36 0 0 0.00 / 716.58 2 2
3 7 2004.56 45 14.15 2829 1801 2.00 / 718.38 2 2
4 13 1592.84 21 14.26 2369 709 2.71 / 719.09 2 2
5 13 1158.44 21 14.38 1821 550 3.26 / 719.64 2 2
6 13 425.32 21 14.72 901 279 3.54 / 719.92 2 2
7 13 30.68 21 14.92 388 122 3.66 / 720.04 2 2
8 8 0.08 170 14.89 336 851 4.51 / 720.89 2 3
Average= 4.37
(KJ/cycle)

Cycle 163 GMT 18/ 3/2022 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 14.85 471 196 0.20 / 712.26 2 2
2 7 2004.48 45 14.15 2842 1810 2.01 / 714.07 2 2
3 13 1588.84 21 14.26 2353 705 2.71 / 714.78 2 2
4 13 1032.68 21 14.45 1664 505 3.22 / 715.28 2 2
5 13 323.00 21 14.77 769 239 3.45 / 715.52 2 2
6 8 0.16 170 14.90 339 859 4.31 / 716.38 2 3
Average= 4.37
(KJ/cycle)

Cycle 162 GMT 8/ 3/2022 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 28 14.85 481 200 0.20 / 707.96 2 2
2 7 2004.56 45 14.16 2818 1796 2.00 / 709.76 2 2
3 13 1592.00 21 14.25 2357 705 2.70 / 710.46 2 2
4 13 910.64 21 14.51 1491 454 3.16 / 710.92 2 2
5 13 490.68 21 14.69 975 301 3.46 / 711.22 2 2
6 8 0.32 170 14.90 336 851 4.31 / 712.07 2 4
Average= 4.37
(KJ/cycle)

Cycle 161 GMT 26/ 2/2022 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 14.85 487 202 0.20 / 703.61 2 2
2 3 1018.00 1 15.04 1726 26 0.23 / 703.64 2 2
3 7 2003.64 45 14.14 2891 1840 2.07 / 705.48 2 2
4 13 1595.00 21 14.27 2348 704 2.77 / 706.18 2 2
5 13 1024.12 21 14.45 1640 498 3.27 / 706.68 2 2
6 13 313.76 21 14.78 750 233 3.50 / 706.91 2 2
7 8 0.20 170 14.90 336 851 4.35 / 707.76 2 3
Average= 4.37
(KJ/cycle)

Cycle 160 GMT 16/ 2/2022 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 28 14.86 476 198 0.20 / 699.23 2 2
2 7 2003.84 45 14.17 2815 1795 1.99 / 701.02 2 2
3 13 1726.08 21 14.23 2497 746 2.74 / 701.77 2 2
4 13 1019.12 21 14.46 1633 496 3.24 / 702.27 2 2
5 13 445.48 21 14.71 927 286 3.52 / 702.55 2 2
6 8 0.32 170 14.90 338 856 4.38 / 703.41 2 3
Average= 4.37
(KJ/cycle)

Cycle 159 GMT 6/ 2/2022 16:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.85 474 197 0.20 / 694.84 2 2
2 7 2004.44 46 14.15 2850 1855 2.05 / 696.70 2 2
3 13 1479.08 21 14.30 2214 665 2.72 / 697.36 2 2
4 13 1069.84 21 14.43 1703 516 3.23 / 697.88 2 2
5 13 489.80 21 14.68 983 303 3.54 / 698.18 2 2
6 8 -0.28 170 14.90 336 851 4.39 / 699.03 2 2
Average= 4.37
(KJ/cycle)

Cycle 158 GMT 27/ 1/2022 16:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 28 14.85 483 201 0.20 / 690.55 2 2
2 7 2008.44 45 14.16 2840 1810 2.01 / 692.36 2 2
3 13 1603.08 21 14.26 2367 709 2.72 / 693.07 2 2
4 13 904.64 21 14.52 1475 450 3.17 / 693.52 2 2
5 13 372.08 21 14.76 829 257 3.43 / 693.77 2 2
6 8 -0.16 170 14.90 344 871 4.30 / 694.64 2 3
Average= 4.37
(KJ/cycle)

Cycle 157 GMT 17/ 1/2022 16:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 28 14.85 480 200 0.20 / 686.20 2 2
2 7 2002.16 45 14.15 2877 1832 2.03 / 688.03 2 2
3 13 1586.48 21 14.27 2355 706 2.74 / 688.74 2 2
4 13 1023.60 21 14.46 1625 493 3.23 / 689.23 2 2
5 13 325.48 21 14.78 768 238 3.47 / 689.47 2 2
6 8 0.52 170 14.90 346 876 4.35 / 690.35 2 4
Average= 4.37
(KJ/cycle)

Cycle 156 GMT 7/ 1/2022 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 14.86 472 196 0.20 / 681.88 2 2
2 7 2002.20 45 14.16 2864 1825 2.02 / 683.71 2 2
3 13 1583.96 21 14.28 2324 697 2.72 / 684.41 2 2
4 13 1022.88 21 14.46 1635 496 3.21 / 684.90 2 2
5 13 329.16 21 14.78 771 239 3.45 / 685.14 2 2
6 8 0.04 170 14.91 339 859 4.31 / 686.00 2 2
Average= 4.37
(KJ/cycle)

Cycle 155 GMT 28/12/2021 17:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 14.85 478 192 0.19 / 677.49 2 2
2 7 2001.48 45 14.16 2845 1813 2.00 / 679.30 2 2
3 13 1584.88 21 14.28 2351 705 2.71 / 680.01 2 2
4 13 1156.76 21 14.40 1800 544 3.25 / 680.55 2 2
5 13 431.08 21 14.73 910 281 3.54 / 680.83 2 2
6 8 -0.16 170 14.90 337 854 4.39 / 681.69 2 3
Average= 4.37
(KJ/cycle)

Cycle 154 GMT 18/12/2021 17:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 26 14.85 480 185 0.19 / 672.99 2 2
2 3 1030.64 1 14.98 1753 26 0.21 / 673.01 2 2
3 7 2002.04 46 14.16 2847 1854 2.07 / 674.87 2 2
4 13 1582.48 21 14.27 2355 706 2.77 / 675.57 2 2
5 13 1154.92 21 14.41 1786 540 3.31 / 676.11 2 2
6 13 564.80 21 14.66 1064 328 3.64 / 676.44 2 2
7 8 0.24 170 14.90 338 856 4.50 / 677.30 2 3
Average= 4.37
(KJ/cycle)

Cycle 153 GMT 8/12/2021 17:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 27 14.84 493 198 0.20 / 668.55 2 2
2 3 969.56 -1 15.38 0 0 0.00 / 668.55 2 2
3 7 2003.24 46 14.15 2877 1873 2.07 / 670.43 2 2
4 13 1725.52 21 14.23 2537 758 2.83 / 671.19 2 2
5 13 987.28 21 14.48 1586 482 3.31 / 671.67 2 2
6 13 424.48 21 14.74 900 279 3.59 / 671.95 2 2
7 8 0.16 170 14.91 338 857 4.45 / 672.80 2 3
Average= 4.37
(KJ/cycle)

Cycle 152 GMT 28/11/2021 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 27 14.84 489 196 0.20 / 663.71 2 2
2 7 2002.48 46 14.16 2852 1858 2.05 / 665.57 2 2
3 13 1723.80 21 14.24 2517 753 2.81 / 666.32 2 2
4 13 1145.44 21 14.42 1793 543 3.35 / 666.86 2 2
5 13 418.08 21 14.74 888 275 3.62 / 667.14 2 2
6 8 0.12 170 14.90 341 864 4.49 / 668.00 2 4
7 14 0.12 70 14.87 340 354 4.84 / 668.36 2 2
Average= 4.37
(KJ/cycle)

Cycle 151 GMT 18/11/2021 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 27 14.85 474 190 0.19 / 659.30 2 2
2 3 1027.00 1 15.02 1774 27 0.22 / 659.33 2 2
3 7 2007.80 45 14.16 2865 1826 2.04 / 661.15 2 2
4 13 1596.24 21 14.29 2343 703 2.75 / 661.86 2 2
5 13 1032.56 21 14.46 1653 502 3.25 / 662.36 2 2
6 13 467.32 21 14.71 951 294 3.54 / 662.65 2 2
7 8 0.28 170 14.90 341 864 4.40 / 663.51 2 3
Average= 4.37
(KJ/cycle)

Cycle 150 GMT 8/11/2021 18:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 27 14.85 495 198 0.20 / 654.96 2 2
2 7 2004.04 45 14.17 2819 1798 2.00 / 656.76 2 2
3 13 1588.72 21 14.27 2354 705 2.70 / 657.47 2 2
4 13 1021.72 21 14.47 1634 497 3.20 / 657.96 2 2
5 13 456.72 21 14.72 937 290 3.49 / 658.25 2 2
6 8 -0.20 170 14.91 338 857 4.34 / 659.11 2 2
Average= 4.36
(KJ/cycle)

Cycle 149 GMT 29/10/2021 18:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 26 14.85 494 191 0.19 / 650.47 2 2
2 7 2003.40 45 14.18 2828 1805 2.00 / 652.28 2 2
3 13 1724.64 21 14.24 2478 741 2.74 / 653.02 2 2
4 13 1138.32 21 14.43 1778 539 3.28 / 653.56 2 2
5 13 551.48 21 14.68 1053 325 3.60 / 653.88 2 2
6 8 0.64 170 14.90 349 884 4.48 / 654.77 2 3
Average= 4.37
(KJ/cycle)

Cycle 148 GMT 19/10/2021 18:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 28 14.84 485 202 0.20 / 646.03 2 2
2 3 948.00 -1 15.38 0 0 0.00 / 646.03 2 2
3 7 2004.88 45 14.17 2861 1824 2.03 / 647.85 2 2
4 13 1723.68 21 14.24 2521 754 2.78 / 648.61 2 2
5 13 1017.56 21 14.47 1630 495 3.28 / 649.10 2 2
6 13 460.00 21 14.72 943 292 3.57 / 649.39 2 2
7 8 0.24 170 14.90 351 889 4.46 / 650.28 2 7
Average= 4.36
(KJ/cycle)

Cycle 147 GMT 9/10/2021 18:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 26 14.86 480 185 0.19 / 641.39 2 2
2 10 1025.44 3 14.75 1706 75 0.26 / 641.46 2 2
3 7 2005.12 45 14.18 2815 1796 2.06 / 643.26 2 2
4 13 1730.72 21 14.24 2509 750 2.81 / 644.01 2 2
5 13 1144.20 21 14.42 1773 537 3.34 / 644.55 2 2
6 13 424.48 21 14.74 898 278 3.62 / 644.83 2 2
7 13 27.88 21 14.94 388 122 3.74 / 644.95 2 2
8 8 -0.28 170 14.90 347 879 4.62 / 645.83 2 4
Average= 4.36
(KJ/cycle)

Cycle 146 GMT 29/ 9/2021 19: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 27 14.84 481 193 0.19 / 637.09 2 2
2 3 957.32 -1 15.38 0 0 0.00 / 637.09 2 2
3 7 2006.24 45 14.17 2836 1808 2.00 / 638.90 2 2
4 13 1591.76 21 14.29 2356 707 2.71 / 639.60 2 2
5 13 907.80 21 14.53 1483 453 3.16 / 640.06 2 2
6 13 486.64 21 14.71 968 299 3.46 / 640.35 2 2
7 8 0.16 170 14.91 335 849 4.31 / 641.20 2 3
Average= 4.36
(KJ/cycle)

Cycle 145 GMT 19/ 9/2021 19: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 26 14.86 482 186 0.19 / 632.17 2 2
2 3 1036.88 1 14.99 1747 26 0.21 / 632.20 2 2
3 7 2002.60 45 14.16 2882 1836 2.05 / 634.03 2 2
4 13 1721.48 21 14.25 2477 741 2.79 / 634.77 2 2
5 13 1132.44 21 14.43 1763 534 3.32 / 635.31 2 2
6 13 404.92 21 14.75 865 268 3.59 / 635.58 2 2
7 13 23.04 21 14.95 377 118 3.71 / 635.70 2 2
8 8 -0.20 170 14.90 337 854 4.56 / 636.55 2 3
9 14 -0.20 70 14.87 332 346 4.91 / 636.89 2 7
Average= 4.36
(KJ/cycle)

Cycle 144 GMT 9/ 9/2021 19:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 27 14.86 475 191 0.19 / 627.84 2 2
2 3 961.72 -1 15.38 0 0 0.00 / 627.84 2 2
3 7 2004.36 45 14.17 2866 1828 2.02 / 629.67 2 2
4 13 1598.60 21 14.28 2370 711 2.73 / 630.38 2 2
5 13 1037.56 21 14.47 1659 504 3.23 / 630.89 2 2
6 13 347.48 21 14.79 794 247 3.48 / 631.13 2 2
7 8 -0.04 170 14.92 336 852 4.33 / 631.98 2 4
Average= 4.36
(KJ/cycle)

Cycle 143 GMT 30/ 8/2021 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 26 14.86 472 182 0.18 / 623.39 2 2
2 3 1050.72 1 14.93 1757 26 0.21 / 623.41 2 2
3 7 2006.00 46 14.18 2806 1830 2.04 / 625.24 2 2
4 13 1730.68 21 14.25 2508 751 2.79 / 626.00 2 2
5 13 1137.92 21 14.43 1757 532 3.32 / 626.53 2 2
6 13 419.12 21 14.75 882 273 3.60 / 626.80 2 2
7 8 0.00 170 14.92 336 852 4.45 / 627.65 2 2
Average= 4.36
(KJ/cycle)

Cycle 142 GMT 20/ 8/2021 19:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 27 14.87 479 192 0.19 / 619.10 2 2
2 3 963.80 -1 15.39 0 0 0.00 / 619.10 2 2
3 7 2005.84 45 14.16 2873 1831 2.02 / 620.93 2 2
4 13 1480.56 21 14.32 2212 665 2.69 / 621.60 2 2
5 13 1064.40 21 14.45 1690 513 3.20 / 622.11 2 2
6 13 336.12 21 14.79 779 242 3.44 / 622.35 2 2
7 8 0.36 170 14.91 337 854 4.30 / 623.21 2 3
Average= 4.36
(KJ/cycle)

Cycle 141 GMT 10/ 8/2021 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 27 14.87 476 191 0.19 / 614.67 2 2
2 7 2003.36 45 14.16 2855 1819 2.01 / 616.49 2 2
3 13 1719.88 21 14.25 2518 754 2.76 / 617.24 2 2
4 13 1133.40 21 14.43 1764 535 3.30 / 617.78 2 2
5 13 407.80 21 14.76 870 270 3.57 / 618.05 2 2
6 8 0.40 170 14.92 339 860 4.43 / 618.91 2 5
Average= 4.36
(KJ/cycle)

Cycle 140 GMT 31/ 7/2021 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 27 14.87 478 192 0.19 / 610.19 2 2
2 7 2004.00 46 14.17 2845 1854 2.05 / 612.04 2 2
3 13 1728.76 21 14.24 2500 748 2.79 / 612.79 2 2
4 13 1014.64 21 14.48 1625 494 3.29 / 613.28 2 2
5 13 315.12 21 14.81 750 233 3.52 / 613.51 2 2
6 13 16.36 21 14.96 365 115 3.64 / 613.63 2 2
7 8 0.40 170 14.91 336 852 4.49 / 614.48 2 4
Average= 4.36
(KJ/cycle)

Cycle 139 GMT 21/ 7/2021 20: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 26 14.86 480 185 0.19 / 605.81 2 2
2 3 1053.96 1 14.93 1771 26 0.21 / 605.83 2 2
3 3 1018.44 1 15.09 1768 27 0.24 / 605.86 2 2
4 7 2007.40 45 14.18 2844 1815 2.05 / 607.67 2 2
5 13 1609.56 21 14.28 2357 707 2.76 / 608.38 2 2
6 13 1060.32 21 14.46 1680 510 3.27 / 608.89 2 2
7 13 352.16 21 14.79 804 250 3.52 / 609.14 2 2
8 8 -0.32 170 14.92 336 852 4.37 / 609.99 2 3
Average= 4.36
(KJ/cycle)

Cycle 138 GMT 11/ 7/2021 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 28 14.85 477 198 0.20 / 601.40 2 2
2 3 917.08 -2 15.39 0 0 0.00 / 601.40 2 2
3 7 2002.76 45 14.18 2830 1806 2.00 / 603.20 2 2
4 13 1722.08 21 14.25 2496 747 2.75 / 603.95 2 2
5 13 1133.64 21 14.44 1773 538 3.29 / 604.49 2 2
6 13 406.00 21 14.76 868 269 3.56 / 604.76 2 2
7 8 0.40 170 14.92 341 865 4.42 / 605.62 2 7
Average= 4.36
(KJ/cycle)

Cycle 137 GMT 1/ 7/2021 20:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 14.87 485 202 0.20 / 596.61 2 2
2 3 1021.16 1 15.07 1760 27 0.23 / 596.63 2 2
3 7 2003.48 45 14.17 2864 1826 2.05 / 598.46 2 2
4 13 1586.24 21 14.30 2327 699 2.75 / 599.16 2 2
5 13 1020.76 21 14.47 1649 501 3.25 / 599.66 2 2
6 13 584.36 21 14.67 1090 336 3.59 / 599.99 2 2
7 8 1.24 170 14.92 337 855 4.45 / 600.85 2 3
8 14 1.24 70 14.89 335 349 4.79 / 601.20 2 6
Average= 4.36
(KJ/cycle)

Cycle 136 GMT 21/ 6/2021 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 28 14.87 478 199 0.20 / 592.23 2 2
2 7 2006.76 45 14.18 2812 1794 1.99 / 594.03 2 2
3 13 1601.84 21 14.29 2367 710 2.70 / 594.74 2 2
4 13 1051.92 21 14.47 1672 508 3.21 / 595.25 2 2
5 13 474.64 21 14.72 960 297 3.51 / 595.54 2 2
6 8 -0.12 170 14.92 339 860 4.37 / 596.40 2 2
Average= 4.35
(KJ/cycle)

Cycle 135 GMT 11/ 6/2021 20:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 27 14.88 471 189 0.19 / 587.92 2 2
2 7 2003.96 45 14.17 2874 1833 2.02 / 589.75 2 2
3 13 1477.76 21 14.32 2228 670 2.69 / 590.42 2 2
4 13 1063.08 21 14.45 1673 508 3.20 / 590.93 2 2
5 13 356.36 21 14.78 809 251 3.45 / 591.18 2 2
6 8 0.08 170 14.92 336 852 4.30 / 592.04 2 6
Average= 4.35
(KJ/cycle)

Cycle 134 GMT 1/ 6/2021 20:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 28 14.88 476 198 0.20 / 583.55 2 2
2 7 2006.32 45 14.17 2881 1837 2.04 / 585.39 2 2
3 13 1590.68 21 14.30 2337 702 2.74 / 586.09 2 2
4 13 1031.92 21 14.48 1655 503 3.24 / 586.59 2 2
5 13 453.28 21 14.74 929 288 3.53 / 586.88 2 2
6 8 0.16 170 14.93 335 850 4.38 / 587.73 2 3
Average= 4.35
(KJ/cycle)

Cycle 133 GMT 22/ 5/2021 20:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 27 14.89 463 186 0.19 / 579.10 2 2
2 3 1031.32 1 15.02 1767 27 0.21 / 579.13 2 2
3 7 2003.48 46 14.17 2867 1869 2.08 / 581.00 2 2
4 13 1594.80 21 14.29 2345 704 2.79 / 581.70 2 2
5 13 1040.04 21 14.48 1663 506 3.29 / 582.21 2 2
6 13 463.72 21 14.73 941 291 3.58 / 582.50 2 2
7 8 0.12 170 14.92 338 857 4.44 / 583.35 2 5
Average= 4.35
(KJ/cycle)

Cycle 132 GMT 12/ 5/2021 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 27 14.89 464 187 0.19 / 574.77 2 2
2 7 2001.64 45 14.18 2844 1815 2.00 / 576.58 2 2
3 13 1720.64 21 14.26 2511 752 2.75 / 577.33 2 2
4 13 885.24 21 14.56 1453 444 3.20 / 577.78 2 2
5 13 461.96 21 14.74 934 289 3.49 / 578.07 2 2
6 8 -0.08 170 14.93 334 848 4.33 / 578.92 2 2
Average= 4.35
(KJ/cycle)

Cycle 131 GMT 2/ 5/2021 20:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 28 14.87 468 195 0.19 / 570.33 2 2
2 7 2004.16 45 14.19 2859 1826 2.02 / 572.16 2 2
3 13 1731.08 21 14.25 2521 754 2.77 / 572.91 2 2
4 13 1135.08 21 14.44 1786 542 3.32 / 573.46 2 2
5 13 417.16 21 14.76 888 275 3.59 / 573.73 2 2
6 8 0.40 170 14.93 335 850 4.44 / 574.58 2 3
Average= 4.35
(KJ/cycle)

Cycle 130 GMT 22/ 4/2021 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 14.88 480 200 0.20 / 565.86 2 2
2 7 2004.68 45 14.18 2854 1821 2.02 / 567.68 2 2
3 13 1592.96 21 14.30 2340 703 2.72 / 568.38 2 2
4 13 1033.80 21 14.48 1640 499 3.22 / 568.88 2 2
5 13 460.40 21 14.74 945 293 3.52 / 569.17 2 2
6 13 16.08 21 14.97 364 114 3.63 / 569.29 2 2
7 8 0.32 170 14.92 335 850 4.48 / 570.14 2 2
Average= 4.35
(KJ/cycle)

Cycle 129 GMT 12/ 4/2021 21:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 28 14.89 470 196 0.20 / 561.39 2 2
2 7 2003.68 45 14.20 2812 1797 1.99 / 563.19 2 2
3 13 1603.08 21 14.31 2348 706 2.70 / 563.89 2 2
4 13 1041.04 21 14.48 1657 504 3.20 / 564.40 2 2
5 13 462.84 21 14.74 938 290 3.49 / 564.69 2 2
6 13 13.40 21 14.97 362 114 3.61 / 564.80 2 2
7 8 0.08 170 14.92 339 860 4.47 / 565.66 2 3
Average= 4.35
(KJ/cycle)

Cycle 128 GMT 2/ 4/2021 21:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 26 14.88 480 186 0.19 / 556.80 2 2
2 3 1061.04 2 14.90 1772 53 0.24 / 556.85 2 2
3 3 1020.88 1 15.09 1775 27 0.27 / 556.88 2 2
4 7 2004.88 45 14.18 2862 1826 2.09 / 558.70 2 2
5 13 1733.68 21 14.25 2547 762 2.85 / 559.47 2 2
6 13 1129.16 21 14.45 1766 536 3.39 / 560.00 2 2
7 13 539.64 21 14.70 1038 320 3.71 / 560.32 2 2
8 8 0.16 170 14.93 343 871 4.58 / 561.19 2 2
Average= 4.35
(KJ/cycle)

Cycle 127 GMT 23/ 3/2021 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 14.88 476 198 0.20 / 552.42 2 2
2 3 944.36 -1 15.40 0 0 0.00 / 552.42 2 2
3 7 2004.20 45 14.20 2819 1801 2.00 / 554.22 2 2
4 13 1598.04 21 14.30 2376 714 2.71 / 554.94 2 2
5 13 1032.44 21 14.48 1649 501 3.21 / 555.44 2 2
6 13 451.92 21 14.74 935 289 3.50 / 555.73 2 2
7 8 0.24 170 14.93 349 886 4.39 / 556.61 2 3
Average= 4.35
(KJ/cycle)

Cycle 126 GMT 13/ 3/2021 22: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 14.90 465 194 0.19 / 547.62 2 2
2 7 2005.28 45 14.20 2816 1799 1.99 / 549.42 2 2
3 13 1597.48 21 14.30 2346 705 2.70 / 550.13 2 2
4 13 1038.48 21 14.48 1655 503 3.20 / 550.63 2 2
5 13 342.00 21 14.80 794 247 3.45 / 550.88 2 2
6 13 19.92 21 14.97 371 117 3.56 / 550.99 2 2
7 8 0.00 170 14.93 344 873 4.44 / 551.87 2 2
8 14 0.00 70 14.89 343 358 4.80 / 552.22 2 10
Average= 4.35
(KJ/cycle)

Cycle 125 GMT 3/ 3/2021 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 26 14.90 466 181 0.18 / 543.19 2 2
2 10 1018.00 3 14.78 1689 75 0.26 / 543.27 2 2
3 7 2003.36 45 14.20 2840 1815 2.07 / 545.08 2 2
4 13 1584.12 21 14.32 2312 695 2.77 / 545.78 2 2
5 13 1143.64 21 14.44 1778 539 3.30 / 546.31 2 2
6 13 410.52 21 14.78 871 270 3.57 / 546.58 2 2
7 8 0.08 170 14.94 332 843 4.42 / 547.43 2 3
Average= 4.34
(KJ/cycle)

Cycle 124 GMT 21/ 2/2021 22:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 14.88 462 192 0.19 / 538.89 2 2
2 3 916.32 -2 15.40 0 0 0.00 / 538.89 2 2
3 7 2004.28 45 14.20 2837 1813 2.01 / 540.70 2 2
4 13 1599.68 21 14.31 2355 708 2.71 / 541.41 2 2
5 13 1025.68 21 14.49 1641 499 3.21 / 541.91 2 2
6 13 335.68 21 14.81 778 242 3.45 / 542.15 2 2
7 8 0.16 170 14.94 338 858 4.31 / 543.01 2 3
Average= 4.34
(KJ/cycle)

Cycle 123 GMT 11/ 2/2021 22:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 28 14.89 473 197 0.20 / 534.10 2 2
2 7 2003.12 45 14.21 2818 1802 2.00 / 535.90 2 2
3 13 1591.72 21 14.31 2337 702 2.70 / 536.60 2 2
4 13 1024.84 21 14.49 1635 498 3.20 / 537.10 2 2
5 13 453.76 21 14.75 934 289 3.49 / 537.39 2 2
6 13 14.08 21 14.97 364 114 3.60 / 537.50 2 2
7 8 0.08 170 14.93 335 850 4.45 / 538.35 2 2
8 14 0.08 70 14.90 330 344 4.80 / 538.70 2 4
Average= 4.34
(KJ/cycle)

Cycle 122 GMT 1/ 2/2021 22:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 27 14.89 475 191 0.19 / 529.71 2 2
2 3 1045.88 1 14.99 1779 27 0.22 / 529.74 2 2
3 7 2004.92 45 14.19 2842 1815 2.03 / 531.55 2 2
4 13 1586.08 21 14.32 2337 703 2.74 / 532.25 2 2
5 13 1023.68 21 14.49 1647 501 3.24 / 532.76 2 2
6 13 444.28 21 14.75 922 286 3.52 / 533.04 2 2
7 8 0.24 170 14.94 338 858 4.38 / 533.90 2 4
Average= 4.34
(KJ/cycle)

Cycle 121 GMT 22/ 1/2021 22:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 27 14.90 470 189 0.19 / 525.42 2 2
2 7 2004.84 45 14.20 2824 1805 1.99 / 527.22 2 2
3 13 1599.52 21 14.30 2353 707 2.70 / 527.93 2 2
4 13 1031.12 21 14.49 1651 502 3.20 / 528.43 2 2
5 13 325.64 21 14.82 764 238 3.44 / 528.67 2 2
6 8 0.40 170 14.94 335 851 4.29 / 529.52 2 9
Average= 4.34
(KJ/cycle)

Cycle 120 GMT 12/ 1/2021 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 28 14.89 469 196 0.20 / 521.05 2 2
2 3 968.36 -1 15.41 0 0 0.00 / 521.05 2 2
3 7 2002.88 45 14.20 2851 1822 2.02 / 522.87 2 2
4 13 1600.40 21 14.31 2350 706 2.72 / 523.58 2 2
5 13 1032.52 21 14.49 1649 502 3.23 / 524.08 2 2
6 13 462.60 21 14.74 942 292 3.52 / 524.37 2 2
7 8 -0.16 170 14.94 338 858 4.38 / 525.23 2 3
Average= 4.34
(KJ/cycle)

Cycle 119 GMT 2/ 1/2021 22:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 27 14.90 471 189 0.19 / 516.61 2 2
2 3 1044.88 1 14.98 1731 26 0.22 / 516.64 2 2
3 7 2002.20 45 14.19 2855 1823 2.04 / 518.46 2 2
4 13 1594.28 21 14.32 2319 697 2.74 / 519.16 2 2
5 13 1030.68 21 14.49 1642 500 3.24 / 519.66 2 2
6 13 589.04 21 14.68 1103 340 3.58 / 520.00 2 2
7 8 0.04 170 14.94 336 853 4.43 / 520.85 2 2
Average= 4.34
(KJ/cycle)

Cycle 118 GMT 23/12/2020 22:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 27 14.89 468 188 0.19 / 512.29 2 2
2 7 2003.44 45 14.20 2854 1824 2.01 / 514.11 2 2
3 13 1603.96 21 14.30 2398 720 2.73 / 514.83 2 2
4 13 1041.76 21 14.49 1649 502 3.23 / 515.33 2 2
5 13 340.60 21 14.82 784 244 3.48 / 515.58 2 2
6 8 -0.24 170 14.95 334 849 4.33 / 516.42 2 2
Average= 4.34
(KJ/cycle)

Cycle 117 GMT 13/12/2020 22:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 14.89 479 200 0.20 / 507.92 2 2
2 7 2003.32 45 14.20 2850 1821 2.02 / 509.74 2 2
3 13 1599.32 21 14.32 2348 706 2.73 / 510.45 2 2
4 13 1034.40 21 14.50 1648 502 3.23 / 510.95 2 2
5 13 463.44 21 14.75 944 292 3.52 / 511.24 2 2
6 8 0.12 170 14.95 337 856 4.38 / 512.10 2 4
Average= 4.34
(KJ/cycle)

Cycle 116 GMT 3/12/2020 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 27 14.89 482 194 0.19 / 503.46 2 2
2 3 1023.48 1 15.07 1757 26 0.22 / 503.49 2 2
3 7 2003.88 45 14.19 2871 1833 2.05 / 505.32 2 2
4 13 1730.68 21 14.27 2531 758 2.81 / 506.08 2 2
5 13 1006.40 21 14.52 1614 492 3.30 / 506.57 2 2
6 13 438.52 21 14.77 916 284 3.59 / 506.86 2 2
7 8 0.36 170 14.94 340 864 4.45 / 507.72 2 4
Average= 4.34
(KJ/cycle)

Cycle 115 GMT 23/11/2020 23:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 26 14.89 476 184 0.18 / 499.12 2 2
2 3 1025.28 1 15.06 1748 26 0.21 / 499.14 2 2
3 7 2003.24 45 14.20 2847 1819 2.03 / 500.96 2 2
4 13 1589.32 21 14.32 2335 702 2.73 / 501.67 2 2
5 13 1020.36 21 14.50 1645 501 3.23 / 502.17 2 2
6 13 313.28 21 14.83 761 237 3.47 / 502.40 2 2
7 8 0.08 170 14.94 340 864 4.33 / 503.27 2 2
Average= 4.34
(KJ/cycle)

Cycle 114 GMT 13/11/2020 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 27 14.89 471 189 0.19 / 494.78 2 2
2 3 965.60 -1 15.41 0 0 0.00 / 494.78 2 2
3 7 2004.04 45 14.20 2846 1819 2.01 / 496.60 2 2
4 13 1589.20 21 14.31 2315 696 2.70 / 497.29 2 2
5 13 1021.96 21 14.50 1635 498 3.20 / 497.79 2 2
6 13 441.88 21 14.77 913 283 3.48 / 498.07 2 2
7 8 0.28 170 14.94 339 861 4.35 / 498.93 2 3
Average= 4.34
(KJ/cycle)

Cycle 113 GMT 3/11/2020 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 14.89 487 203 0.20 / 490.41 2 2
2 7 2003.12 45 14.20 2874 1836 2.04 / 492.25 2 2
3 13 1588.12 21 14.33 2319 698 2.74 / 492.95 2 2
4 13 1027.92 21 14.51 1625 495 3.23 / 493.44 2 2
5 13 450.48 21 14.76 927 287 3.52 / 493.73 2 2
6 8 -0.12 170 14.94 338 858 4.38 / 494.59 2 3
Average= 4.34
(KJ/cycle)

Cycle 112 GMT 24/10/2020 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 28 14.88 493 205 0.21 / 486.09 2 2
2 7 2006.44 45 14.22 2816 1802 2.01 / 487.89 2 2
3 13 1599.32 21 14.32 2345 705 2.71 / 488.60 2 2
4 13 1041.92 21 14.50 1656 504 3.22 / 489.10 2 2
5 13 328.84 21 14.83 776 242 3.46 / 489.34 2 2
6 8 0.20 170 14.95 341 867 4.33 / 490.21 2 4
Average= 4.34
(KJ/cycle)

Cycle 111 GMT 15/10/2020 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 26 14.88 492 190 0.19 / 481.52 2 2
2 3 1075.48 2 14.88 1808 54 0.24 / 481.58 2 2
3 3 1019.88 1 15.13 1761 27 0.27 / 481.60 2 2
4 7 2003.64 45 14.21 2860 1829 2.10 / 483.43 2 2
5 13 1469.32 21 14.37 2202 664 2.76 / 484.10 2 2
6 13 1056.08 21 14.48 1682 511 3.28 / 484.61 2 2
7 13 473.36 21 14.74 959 297 3.57 / 484.91 2 2
8 13 13.04 21 14.98 368 116 3.69 / 485.02 2 2
9 8 0.36 170 14.93 340 863 4.55 / 485.89 2 3
Average= 4.34
(KJ/cycle)

Cycle 110 GMT 5/10/2020 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 27 14.89 484 195 0.19 / 477.20 2 2
2 3 967.24 -1 15.42 0 0 0.00 / 477.20 2 2
3 7 2003.60 45 14.21 2855 1826 2.02 / 479.02 2 2
4 13 1597.56 21 14.32 2354 708 2.73 / 479.73 2 2
5 13 1029.84 21 14.51 1637 499 3.23 / 480.23 2 2
6 13 323.00 21 14.84 761 237 3.46 / 480.47 2 2
7 8 -0.08 170 14.95 341 867 4.33 / 481.33 2 4
Average= 4.34
(KJ/cycle)

Cycle 109 GMT 25/ 9/2020 0:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 26 14.89 487 189 0.19 / 472.69 2 2
2 3 1023.04 1 15.08 1758 27 0.22 / 472.71 2 2
3 7 2008.28 45 14.18 2909 1856 2.07 / 474.57 2 2
4 13 1597.72 21 14.34 2330 702 2.77 / 475.27 2 2
5 13 1034.24 21 14.50 1651 503 3.28 / 475.77 2 2
6 13 319.00 21 14.84 762 237 3.51 / 476.01 2 2
7 13 36.72 21 14.97 401 126 3.64 / 476.14 2 2
8 8 0.36 170 14.94 341 866 4.51 / 477.00 2 4
Average= 4.34
(KJ/cycle)

Cycle 108 GMT 15/ 9/2020 0:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 27 14.89 477 192 0.19 / 468.19 2 2
2 7 2002.76 45 14.20 2852 1822 2.01 / 470.01 2 2
3 13 1727.76 21 14.27 2550 764 2.78 / 470.78 2 2
4 13 1004.80 21 14.53 1600 488 3.27 / 471.27 2 2
5 13 325.04 21 14.84 771 240 3.51 / 471.51 2 2
6 13 36.16 21 14.98 398 125 3.63 / 471.63 2 2
7 8 0.40 170 14.95 341 867 4.50 / 472.50 2 8
Average= 4.33
(KJ/cycle)

Cycle 107 GMT 5/ 9/2020 0:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 26 14.90 484 188 0.19 / 463.72 2 2
2 3 1042.68 1 14.99 1757 26 0.21 / 463.74 2 2
3 7 2003.88 45 14.21 2845 1819 2.03 / 465.56 2 2
4 13 1724.04 21 14.29 2515 755 2.79 / 466.32 2 2
5 13 1138.00 21 14.47 1783 542 3.33 / 466.86 2 2
6 13 407.48 21 14.79 878 273 3.60 / 467.13 2 2
7 8 0.08 170 14.95 342 869 4.47 / 468.00 2 3
Average= 4.33
(KJ/cycle)

Cycle 106 GMT 26/ 8/2020 0:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 27 14.89 476 191 0.19 / 459.26 2 2
2 3 971.64 -1 15.45 0 0 0.00 / 459.26 2 2
3 7 2002.68 46 14.20 2878 1880 2.07 / 461.14 2 2
4 13 1726.08 21 14.29 2505 752 2.82 / 461.89 2 2
5 13 995.48 21 14.53 1597 487 3.31 / 462.38 2 2
6 13 425.92 21 14.78 900 279 3.59 / 462.66 2 2
7 8 0.04 170 14.96 341 867 4.46 / 463.53 2 2
Average= 4.33
(KJ/cycle)

Cycle 105 GMT 16/ 8/2020 0:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 26 14.88 485 188 0.19 / 454.73 2 2
2 3 1029.76 1 15.06 1757 26 0.21 / 454.76 2 2
3 7 2005.48 45 14.21 2837 1814 2.03 / 456.57 2 2
4 13 1599.00 21 14.33 2340 704 2.73 / 457.27 2 2
5 13 1030.04 21 14.51 1640 500 3.23 / 457.77 2 2
6 13 450.68 21 14.77 925 287 3.52 / 458.06 2 2
7 13 67.20 21 14.96 443 139 3.66 / 458.20 2 2
8 8 0.20 170 14.94 343 871 4.53 / 459.07 2 6
Average= 4.33
(KJ/cycle)

Cycle 104 GMT 6/ 8/2020 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 27 14.90 472 190 0.19 / 449.91 2 2
2 3 955.04 -1 15.42 0 0 0.00 / 449.91 2 2
3 7 2004.44 45 14.22 2817 1803 1.99 / 451.71 2 2
4 13 1595.44 21 14.33 2355 709 2.70 / 452.42 2 2
5 13 1025.60 21 14.51 1643 501 3.20 / 452.92 2 2
6 13 452.56 21 14.77 933 289 3.49 / 453.21 2 2
7 13 30.24 21 14.98 388 122 3.61 / 453.33 2 2
8 8 0.00 170 14.94 338 858 4.47 / 454.19 2 6
9 14 0.00 70 14.91 337 352 4.82 / 454.54 2 6
Average= 4.33
(KJ/cycle)

Cycle 103 GMT 27/ 7/2020 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 14.90 481 194 0.19 / 445.49 2 2
2 7 2002.00 46 14.21 2846 1860 2.05 / 447.35 2 2
3 13 1588.32 21 14.33 2351 707 2.76 / 448.06 2 2
4 13 1016.72 21 14.52 1630 497 3.26 / 448.56 2 2
5 13 438.20 21 14.78 918 285 3.54 / 448.84 2 2
6 8 0.28 170 14.95 344 874 4.42 / 449.72 2 3
Average= 4.32
(KJ/cycle)

Cycle 102 GMT 17/ 7/2020 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 14.91 478 200 0.20 / 441.12 2 2
2 7 2005.12 45 14.21 2851 1823 2.02 / 442.94 2 2
3 13 1596.36 21 14.34 2349 707 2.73 / 443.65 2 2
4 13 1019.44 21 14.52 1637 499 3.23 / 444.15 2 2
5 13 440.28 21 14.78 919 285 3.51 / 444.44 2 2
6 8 0.48 170 14.96 340 865 4.38 / 445.30 2 3
Average= 4.32
(KJ/cycle)

Cycle 101 GMT 7/ 7/2020 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 27 14.91 481 194 0.19 / 436.66 2 2
2 3 1018.28 1 15.09 1743 26 0.22 / 436.69 2 2
3 7 2002.16 45 14.21 2847 1821 2.04 / 438.51 2 2
4 13 1723.48 21 14.30 2507 753 2.79 / 439.26 2 2
5 13 1130.20 21 14.48 1753 533 3.33 / 439.80 2 2
6 13 395.04 21 14.81 859 267 3.59 / 440.06 2 2
7 8 -0.16 170 14.96 337 857 4.45 / 440.92 2 3
Average= 4.32
(KJ/cycle)

Cycle 100 GMT 27/ 6/2020 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 27 14.91 479 193 0.19 / 432.38 2 2
2 7 2002.84 45 14.20 2872 1835 2.03 / 434.21 2 2
3 13 1588.40 21 14.33 2354 708 2.74 / 434.92 2 2
4 13 895.24 21 14.58 1472 451 3.19 / 435.37 2 2
5 13 338.68 21 14.83 784 244 3.43 / 435.61 2 2
6 8 0.12 170 14.96 337 857 4.29 / 436.47 2 2
Average= 4.32
(KJ/cycle)

Cycle 99 GMT 17/ 6/2020 1:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 27 14.91 480 193 0.19 / 427.92 2 2
2 3 1019.84 1 15.11 1754 27 0.22 / 427.94 2 2
3 7 2002.00 45 14.23 2813 1801 2.02 / 429.74 2 2
4 13 1726.52 21 14.31 2522 758 2.78 / 430.50 2 2
5 13 1132.84 21 14.48 1769 538 3.32 / 431.04 2 2
6 13 419.64 21 14.79 894 278 3.59 / 431.32 2 2
7 8 0.24 170 14.96 340 865 4.46 / 432.18 2 4
Average= 4.32
(KJ/cycle)

Cycle 98 GMT 7/ 6/2020 1:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 27 14.92 460 185 0.19 / 423.55 2 2
2 7 2003.16 45 14.22 2856 1828 2.01 / 425.38 2 2
3 13 1593.00 21 14.35 2352 709 2.72 / 426.09 2 2
4 13 1011.84 21 14.53 1622 495 3.22 / 426.58 2 2
5 13 441.96 21 14.78 915 284 3.50 / 426.87 2 2
6 8 -0.52 170 14.96 337 857 4.36 / 427.72 2 5
Average= 4.32
(KJ/cycle)

Cycle 97 GMT 28/ 5/2020 1:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 26 14.91 469 182 0.18 / 419.10 2 2
2 3 1054.36 1 14.95 1754 26 0.21 / 419.12 2 2
3 7 2003.00 45 14.22 2856 1828 2.04 / 420.95 2 2
4 13 1594.88 21 14.34 2345 706 2.74 / 421.66 2 2
5 13 1025.20 21 14.52 1645 502 3.24 / 422.16 2 2
6 13 310.68 21 14.85 747 233 3.48 / 422.39 2 2
7 13 16.40 21 15.00 365 115 3.59 / 422.51 2 2
8 8 0.56 170 14.96 338 860 4.45 / 423.37 2 3
Average= 4.32
(KJ/cycle)

Cycle 96 GMT 18/ 5/2020 1:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 28 14.90 482 201 0.20 / 414.61 2 2
2 3 932.40 -1 15.42 0 0 0.00 / 414.61 2 2
3 3 962.92 -1 15.46 0 0 0.00 / 414.61 2 2
4 7 2003.08 45 14.21 2880 1842 2.04 / 416.45 2 2
5 13 1579.68 21 14.36 2338 705 2.75 / 417.16 2 2
6 13 1004.32 21 14.53 1623 495 3.24 / 417.65 2 2
7 13 422.40 21 14.79 896 278 3.52 / 417.93 2 2
8 13 25.08 21 14.99 383 121 3.64 / 418.05 2 2
9 8 0.04 170 14.95 339 862 4.50 / 418.92 2 4
Average= 4.32
(KJ/cycle)

Cycle 95 GMT 8/ 5/2020 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 28 14.92 472 197 0.20 / 409.78 2 2
2 7 2005.52 45 14.22 2825 1808 2.00 / 411.59 2 2
3 13 1594.32 21 14.34 2357 710 2.71 / 412.30 2 2
4 13 1026.52 21 14.52 1628 496 3.21 / 412.79 2 2
5 13 444.60 21 14.78 925 287 3.50 / 413.08 2 2
6 13 12.52 21 15.00 367 116 3.61 / 413.20 2 2
7 8 -0.36 170 14.95 340 864 4.48 / 414.06 2 2
8 14 -0.36 70 14.92 336 351 4.83 / 414.41 2 11
Average= 4.32
(KJ/cycle)

Cycle 94 GMT 28/ 4/2020 1:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 28 14.93 464 194 0.19 / 405.42 2 2
2 7 2003.24 45 14.21 2865 1832 2.03 / 407.25 2 2
3 13 1719.00 21 14.30 2508 753 2.78 / 408.00 2 2
4 13 1002.16 21 14.54 1615 493 3.27 / 408.49 2 2
5 13 292.60 21 14.86 725 226 3.50 / 408.72 2 2
6 8 0.44 170 14.97 339 863 4.36 / 409.58 2 5
Average= 4.31
(KJ/cycle)

Cycle 93 GMT 18/ 4/2020 2: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 28 14.92 471 197 0.20 / 401.14 2 2
2 7 2004.00 45 14.21 2842 1817 2.01 / 402.96 2 2
3 13 1595.04 21 14.34 2354 709 2.72 / 403.66 2 2
4 13 905.52 21 14.58 1478 453 3.18 / 404.12 2 2
5 13 342.00 21 14.84 791 247 3.42 / 404.36 2 2
6 8 0.12 170 14.97 337 858 4.28 / 405.22 2 3
Average= 4.31
(KJ/cycle)

Cycle 92 GMT 8/ 4/2020 2: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 28 14.92 467 195 0.20 / 396.66 2 2
2 7 2002.20 45 14.23 2819 1805 2.00 / 398.46 2 2
3 13 1591.40 21 14.35 2333 703 2.70 / 399.17 2 2
4 13 900.00 21 14.58 1482 454 3.16 / 399.62 2 2
5 13 608.40 21 14.70 1126 348 3.50 / 399.97 2 2
6 13 27.44 21 15.00 384 121 3.63 / 400.09 2 2
7 8 -0.16 170 14.96 336 855 4.48 / 400.94 2 2
Average= 4.31
(KJ/cycle)

Cycle 91 GMT 29/ 3/2020 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 27 14.93 469 189 0.19 / 392.24 2 2
2 3 1027.36 1 15.08 1764 27 0.22 / 392.27 2 2
3 7 2005.76 46 14.21 2871 1877 2.09 / 394.15 2 2
4 13 1594.52 21 14.35 2329 702 2.79 / 394.85 2 2
5 13 904.68 21 14.58 1489 456 3.25 / 395.30 2 2
6 13 480.08 21 14.76 967 300 3.55 / 395.60 2 2
7 8 0.16 170 14.97 337 858 4.41 / 396.46 2 5
Average= 4.31
(KJ/cycle)

Cycle 90 GMT 19/ 3/2020 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 28 14.94 472 197 0.20 / 387.90 2 2
2 3 968.56 -1 15.43 0 0 0.00 / 387.90 2 2
3 7 2004.96 46 14.22 2816 1842 2.04 / 389.75 2 2
4 13 1592.52 21 14.36 2343 707 2.75 / 390.45 2 2
5 13 1043.68 21 14.52 1663 507 3.25 / 390.96 2 2
6 13 337.60 21 14.84 786 245 3.50 / 391.20 2 2
7 8 0.12 170 14.98 334 851 4.35 / 392.05 2 3
Average= 4.31
(KJ/cycle)

Cycle 89 GMT 9/ 3/2020 2:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 28 14.93 473 198 0.20 / 383.51 2 2
2 3 1021.52 1 15.11 1776 27 0.22 / 383.54 2 2
3 7 2002.00 46 14.22 2846 1862 2.09 / 385.40 2 2
4 13 1590.48 21 14.36 2346 707 2.79 / 386.11 2 2
5 13 1026.28 21 14.54 1634 499 3.29 / 386.61 2 2
6 13 324.28 21 14.85 766 239 3.53 / 386.85 2 2
7 8 0.28 170 14.98 338 861 4.39 / 387.71 2 3
Average= 4.31
(KJ/cycle)

Cycle 88 GMT 28/ 2/2020 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 28 14.93 472 197 0.20 / 379.14 2 2
2 7 2004.64 46 14.21 2856 1867 2.06 / 381.01 2 2
3 13 1592.24 21 14.35 2332 703 2.77 / 381.71 2 2
4 13 1025.96 21 14.53 1634 499 3.27 / 382.21 2 2
5 13 326.04 21 14.85 778 243 3.51 / 382.45 2 2
6 8 0.36 170 14.97 338 860 4.37 / 383.31 2 3
Average= 4.31
(KJ/cycle)

Cycle 87 GMT 18/ 2/2020 2:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 27 14.92 478 193 0.19 / 374.72 2 2
2 3 1048.68 1 15.00 1770 27 0.22 / 374.74 2 2
3 7 2002.84 45 14.20 2862 1829 2.05 / 376.57 2 2
4 13 1591.64 21 14.34 2324 700 2.75 / 377.27 2 2
5 13 1014.96 21 14.53 1635 499 3.25 / 377.77 2 2
6 13 442.80 21 14.78 929 288 3.54 / 378.06 2 2
7 8 0.16 170 14.96 349 888 4.42 / 378.95 2 4
Average= 4.31
(KJ/cycle)

Cycle 86 GMT 8/ 2/2020 2:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 14.92 473 198 0.20 / 370.27 2 2
2 3 960.52 -1 15.43 0 0 0.00 / 370.27 2 2
3 7 2005.36 45 14.21 2835 1813 2.01 / 372.09 2 2
4 13 1595.88 21 14.35 2349 708 2.72 / 372.80 2 2
5 13 1028.36 21 14.53 1644 502 3.22 / 373.30 2 2
6 13 592.28 21 14.71 1110 343 3.56 / 373.64 2 2
7 8 -0.32 170 14.96 347 882 4.45 / 374.52 2 2
Average= 4.30
(KJ/cycle)

Cycle 85 GMT 29/ 1/2020 2:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 27 14.94 467 188 0.19 / 365.92 2 2
2 3 1027.24 1 15.09 1740 26 0.21 / 365.95 2 2
3 7 2006.60 45 14.21 2838 1815 2.03 / 367.76 2 2
4 13 1476.20 21 14.40 2183 660 2.69 / 368.42 2 2
5 13 1046.60 21 14.52 1659 506 3.20 / 368.93 2 2
6 13 460.32 21 14.78 935 290 3.49 / 369.22 2 2
7 8 -0.16 170 14.97 337 858 4.34 / 370.08 2 9
Average= 4.30
(KJ/cycle)

Cycle 84 GMT 19/ 1/2020 2:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 27 14.93 475 191 0.19 / 361.57 2 2
2 3 1032.64 1 15.06 1766 27 0.22 / 361.59 2 2
3 7 2002.28 46 14.22 2798 1830 2.05 / 363.43 2 2
4 13 1598.72 21 14.35 2348 708 2.76 / 364.13 2 2
5 13 1037.24 21 14.53 1653 504 3.26 / 364.64 2 2
6 13 329.08 21 14.85 774 241 3.50 / 364.88 2 2
7 8 0.04 170 14.98 336 856 4.36 / 365.73 2 5
Average= 4.30
(KJ/cycle)

Cycle 83 GMT 9/ 1/2020 2:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 26 14.92 469 182 0.18 / 357.14 2 2
2 3 1023.80 1 15.10 1751 26 0.21 / 357.16 2 2
3 7 2004.92 45 14.21 2847 1821 2.03 / 358.98 2 2
4 13 1721.52 21 14.32 2508 754 2.78 / 359.74 2 2
5 13 1000.24 21 14.55 1610 492 3.28 / 360.23 2 2
6 13 430.72 21 14.80 905 281 3.56 / 360.51 2 2
7 8 0.20 170 14.98 340 866 4.42 / 361.38 2 3
Average= 4.30
(KJ/cycle)

Cycle 82 GMT 30/12/2019 2:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 27 14.92 471 190 0.19 / 352.71 2 2
2 3 970.88 -1 15.44 0 0 0.00 / 352.71 2 2
3 7 2008.44 45 14.22 2835 1814 2.00 / 354.52 2 2
4 13 1604.28 21 14.35 2365 713 2.72 / 355.23 2 2
5 13 1039.08 21 14.53 1648 503 3.22 / 355.74 2 2
6 13 320.40 21 14.86 761 237 3.46 / 355.97 2 2
7 13 14.48 21 15.01 370 117 3.57 / 356.09 2 2
8 8 0.40 170 14.97 340 865 4.44 / 356.95 2 2
Average= 4.30
(KJ/cycle)

Cycle 81 GMT 20/12/2019 2:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 28 14.92 484 202 0.20 / 348.29 2 2
2 7 2002.08 45 14.22 2848 1822 2.02 / 350.11 2 2
3 13 1592.04 21 14.35 2365 713 2.74 / 350.82 2 2
4 13 891.72 21 14.60 1466 449 3.19 / 351.27 2 2
5 13 327.36 21 14.86 771 241 3.43 / 351.51 2 2
6 13 16.96 21 15.01 372 117 3.54 / 351.63 2 2
7 8 0.00 170 14.96 348 885 4.43 / 352.52 2 5
Average= 4.30
(KJ/cycle)

Cycle 80 GMT 10/12/2019 2:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 28 14.91 487 203 0.20 / 343.94 2 2
2 7 2002.32 45 14.21 2852 1824 2.03 / 345.77 2 2
3 13 1588.80 21 14.37 2336 705 2.73 / 346.47 2 2
4 13 1016.76 21 14.54 1626 496 3.23 / 346.97 2 2
5 13 304.08 21 14.87 740 231 3.46 / 347.20 2 2
6 8 0.24 170 14.97 348 886 4.35 / 348.09 2 5
Average= 4.30
(KJ/cycle)

Cycle 79 GMT 30/11/2019 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 27 14.92 495 199 0.20 / 339.56 2 2
2 3 1039.64 1 15.03 1768 27 0.23 / 339.58 2 2
3 7 2006.72 45 14.22 2837 1815 2.04 / 341.40 2 2
4 13 1595.76 21 14.36 2356 710 2.75 / 342.11 2 2
5 13 1026.92 21 14.54 1649 504 3.26 / 342.61 2 2
6 13 305.80 21 14.87 749 234 3.49 / 342.85 2 2
7 8 -0.08 170 14.97 352 896 4.39 / 343.74 2 3
Average= 4.30
(KJ/cycle)

Cycle 78 GMT 20/11/2019 2:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 14.93 483 195 0.19 / 335.12 2 2
2 7 2003.44 45 14.21 2873 1837 2.03 / 336.96 2 2
3 13 1588.64 21 14.36 2360 712 2.74 / 337.67 2 2
4 13 1024.40 21 14.55 1628 497 3.24 / 338.17 2 2
5 13 448.92 21 14.80 932 290 3.53 / 338.46 2 2
6 8 0.28 170 14.97 352 896 4.43 / 339.36 2 4
Average= 4.30
(KJ/cycle)

Cycle 77 GMT 10/11/2019 2:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 27 14.93 480 193 0.19 / 330.87 2 2
2 7 2003.68 45 14.23 2807 1797 1.99 / 332.66 2 2
3 13 1464.16 21 14.42 2174 658 2.65 / 333.32 2 2
4 13 1047.12 21 14.54 1648 503 3.15 / 333.82 2 2
5 13 330.88 21 14.86 774 242 3.39 / 334.07 2 2
6 8 0.08 170 14.98 339 863 4.26 / 334.93 2 3
Average= 4.29
(KJ/cycle)

Cycle 76 GMT 31/10/2019 2:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 27 14.93 483 195 0.19 / 326.40 2 2
2 7 2002.52 46 14.23 2824 1849 2.04 / 328.25 2 2
3 13 1729.12 21 14.33 2510 755 2.80 / 329.00 2 2
4 13 1138.76 21 14.50 1768 538 3.34 / 329.54 2 2
5 13 406.96 21 14.83 868 270 3.61 / 329.81 2 2
6 8 0.08 170 14.98 338 861 4.47 / 330.67 2 5
Average= 4.29
(KJ/cycle)

Cycle 75 GMT 21/10/2019 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 26 14.93 480 186 0.19 / 322.05 2 2
2 3 1019.20 1 15.12 1730 26 0.21 / 322.08 2 2
3 7 2008.48 45 14.24 2814 1803 2.02 / 323.88 2 2
4 13 1604.92 21 14.37 2349 709 2.72 / 324.59 2 2
5 13 1047.32 21 14.54 1653 505 3.23 / 325.10 2 2
6 13 332.60 21 14.86 778 243 3.47 / 325.34 2 2
7 8 -0.12 170 14.98 340 866 4.34 / 326.20 2 2
Average= 4.29
(KJ/cycle)

Cycle 74 GMT 11/10/2019 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 27 14.93 479 193 0.19 / 317.71 2 2
2 3 970.44 -1 15.44 0 0 0.00 / 317.71 2 2
3 7 2003.92 46 14.22 2851 1865 2.06 / 319.57 2 2
4 13 1578.28 21 14.37 2324 701 2.76 / 320.27 2 2
5 13 1003.08 21 14.56 1609 492 3.25 / 320.77 2 2
6 13 295.72 21 14.89 733 229 3.48 / 321.00 2 2
7 8 -0.12 170 14.98 342 871 4.35 / 321.87 2 8
Average= 4.29
(KJ/cycle)

Cycle 73 GMT 1/10/2019 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 26 14.93 481 187 0.19 / 313.31 2 2
2 3 1047.20 1 15.02 1750 26 0.21 / 313.34 2 2
3 7 2003.16 45 14.23 2856 1829 2.04 / 315.17 2 2
4 13 1578.80 21 14.37 2374 716 2.76 / 315.88 2 2
5 13 1011.84 21 14.56 1633 499 3.26 / 316.38 2 2
6 13 294.76 21 14.89 735 230 3.49 / 316.61 2 2
7 8 0.76 170 14.98 354 901 4.39 / 317.52 2 2
Average= 4.29
(KJ/cycle)

Cycle 72 GMT 21/ 9/2019 2:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 26 14.93 480 186 0.19 / 308.96 2 2
2 7 2006.76 45 14.23 2862 1833 2.02 / 310.79 2 2
3 13 1603.24 21 14.38 2367 715 2.73 / 311.51 2 2
4 13 1037.88 21 14.55 1650 504 3.24 / 312.01 2 2
5 13 322.44 21 14.88 765 239 3.48 / 312.25 2 2
6 8 0.52 170 14.99 344 877 4.35 / 313.13 2 3
Average= 4.29
(KJ/cycle)

Cycle 71 GMT 11/ 9/2019 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 28 14.93 484 202 0.20 / 304.60 2 2
2 3 963.24 -1 15.44 0 0 0.00 / 304.60 2 2
3 7 2002.64 45 14.23 2862 1833 2.04 / 306.43 2 2
4 13 1587.48 21 14.39 2338 707 2.74 / 307.14 2 2
5 13 896.60 21 14.63 1479 454 3.20 / 307.60 2 2
6 13 203.76 21 14.94 612 192 3.39 / 307.79 2 2
7 13 19.52 21 15.03 375 118 3.51 / 307.91 2 2
8 8 0.00 170 14.99 340 866 4.37 / 308.77 2 3
Average= 4.29
(KJ/cycle)

Cycle 70 GMT 1/ 9/2019 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 27 14.94 489 197 0.20 / 300.05 2 2
2 3 1028.52 1 15.09 1748 26 0.22 / 300.08 2 2
3 7 2002.08 46 14.24 2847 1865 2.09 / 301.94 2 2
4 13 1589.16 21 14.39 2333 705 2.79 / 302.65 2 2
5 13 1152.48 21 14.51 1802 549 3.34 / 303.20 2 2
6 13 550.56 21 14.76 1054 327 3.67 / 303.52 2 2
7 8 0.52 170 14.99 344 877 4.55 / 304.40 2 4
Average= 4.29
(KJ/cycle)

Cycle 69 GMT 22/ 8/2019 2:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 26 14.94 483 188 0.19 / 295.71 2 2
2 7 2005.56 45 14.25 2811 1803 1.99 / 297.51 2 2
3 13 1585.04 21 14.40 2319 701 2.69 / 298.21 2 2
4 13 1015.72 21 14.58 1624 497 3.19 / 298.71 2 2
5 13 438.88 21 14.83 909 283 3.47 / 298.99 2 2
6 8 -0.20 170 15.00 339 864 4.34 / 299.85 2 4
Average= 4.28
(KJ/cycle)

Cycle 68 GMT 12/ 8/2019 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 28 14.94 491 205 0.21 / 291.33 2 2
2 3 960.00 -1 15.45 0 0 0.00 / 291.33 2 2
3 7 2001.84 46 14.25 2817 1847 2.05 / 293.18 2 2
4 13 1721.56 21 14.35 2503 754 2.81 / 293.93 2 2
5 13 988.52 21 14.58 1596 489 3.29 / 294.42 2 2
6 13 292.36 21 14.90 728 228 3.52 / 294.65 2 2
7 8 -0.12 170 15.00 341 870 4.39 / 295.52 2 4
Average= 4.28
(KJ/cycle)

Cycle 67 GMT 2/ 8/2019 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 28 14.94 491 205 0.21 / 286.88 2 2
2 7 2014.24 45 14.23 2876 1842 2.05 / 288.72 2 2
3 13 1603.40 21 14.38 2390 722 2.77 / 289.44 2 2
4 13 1039.00 21 14.56 1667 510 3.28 / 289.95 2 2
5 13 450.36 21 14.82 944 294 3.57 / 290.24 2 2
6 8 0.04 170 15.00 346 882 4.45 / 291.13 2 2
Average= 4.28
(KJ/cycle)

Cycle 66 GMT 23/ 7/2019 2:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 27 14.96 476 192 0.19 / 282.55 2 2
2 7 2002.36 45 14.24 2868 1838 2.03 / 284.39 2 2
3 13 1459.20 21 14.45 2194 666 2.70 / 285.05 2 2
4 13 1032.96 21 14.57 1657 507 3.20 / 285.56 2 2
5 13 328.68 21 14.89 772 241 3.44 / 285.80 2 2
6 8 0.48 170 15.00 341 870 4.31 / 286.67 2 5
Average= 4.28
(KJ/cycle)

Cycle 65 GMT 13/ 7/2019 2:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 27 14.96 480 194 0.19 / 278.19 2 2
2 7 2003.16 45 14.26 2832 1817 2.01 / 280.01 2 2
3 13 1579.08 21 14.41 2336 707 2.72 / 280.72 2 2
4 13 1007.92 21 14.59 1617 495 3.21 / 281.21 2 2
5 13 431.08 21 14.84 907 283 3.50 / 281.50 2 2
6 8 0.00 170 15.01 337 860 4.36 / 282.36 2 3
Average= 4.28
(KJ/cycle)

Cycle 64 GMT 3/ 7/2019 2:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 27 14.97 474 192 0.19 / 273.88 2 2
2 7 2002.00 45 14.25 2858 1833 2.02 / 275.71 2 2
3 13 1580.52 21 14.41 2329 705 2.73 / 276.42 2 2
4 13 1004.56 21 14.60 1610 494 3.22 / 276.91 2 2
5 13 287.00 21 14.92 717 225 3.45 / 277.14 2 2
6 8 0.48 170 15.02 338 863 4.31 / 278.00 2 7
Average= 4.28
(KJ/cycle)

Cycle 63 GMT 23/ 6/2019 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 27 14.97 477 193 0.19 / 269.57 2 2
2 7 2003.44 45 14.25 2860 1834 2.03 / 271.40 2 2
3 13 1580.28 21 14.42 2315 701 2.73 / 272.10 2 2
4 13 1007.04 21 14.59 1607 492 3.22 / 272.59 2 2
5 13 305.72 21 14.91 745 233 3.45 / 272.83 2 2
6 8 0.24 170 15.02 338 863 4.32 / 273.69 2 8
Average= 4.28
(KJ/cycle)

Cycle 62 GMT 13/ 6/2019 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 28 14.97 484 203 0.20 / 265.22 2 2
2 7 2004.80 45 14.25 2859 1833 2.04 / 267.06 2 2
3 13 1585.80 21 14.42 2347 711 2.75 / 267.77 2 2
4 13 1022.56 21 14.60 1632 500 3.25 / 268.27 2 2
5 13 309.84 21 14.91 754 236 3.48 / 268.50 2 2
6 8 0.60 170 15.02 341 871 4.35 / 269.37 2 6
Average= 4.28
(KJ/cycle)

Cycle 61 GMT 3/ 6/2019 3: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 28 14.99 466 196 0.20 / 260.67 2 2
2 7 2002.12 45 14.28 2813 1808 2.00 / 262.48 2 2
3 13 1591.76 21 14.42 2335 707 2.71 / 263.18 2 2
4 13 1163.00 21 14.54 1805 551 3.26 / 263.74 2 2
5 13 426.92 21 14.86 907 283 3.54 / 264.02 2 2
6 13 53.44 21 15.04 421 133 3.68 / 264.15 2 2
7 8 -0.28 170 15.02 340 868 4.55 / 265.02 2 4
Average= 4.27
(KJ/cycle)

Cycle 60 GMT 24/ 5/2019 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 28 14.99 470 197 0.20 / 256.36 2 2
2 7 2002.88 45 14.27 2838 1822 2.02 / 258.19 2 2
3 13 1585.36 21 14.43 2331 706 2.73 / 258.89 2 2
4 13 1016.68 21 14.61 1618 496 3.22 / 259.39 2 2
5 13 290.56 21 14.94 723 227 3.45 / 259.62 2 2
6 8 0.08 170 15.03 336 859 4.31 / 260.47 2 4
Average= 4.27
(KJ/cycle)

Cycle 59 GMT 14/ 5/2019 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 14.99 468 196 0.20 / 251.97 2 2
2 7 2002.32 45 14.27 2862 1838 2.03 / 253.81 2 2
3 13 1727.72 21 14.38 2513 759 2.79 / 254.57 2 2
4 13 1015.56 21 14.61 1629 500 3.29 / 255.07 2 2
5 13 308.72 21 14.93 750 235 3.53 / 255.30 2 2
6 8 -0.16 170 15.04 338 864 4.39 / 256.17 2 3
Average= 4.27
(KJ/cycle)

Cycle 58 GMT 4/ 5/2019 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 29 15.00 480 209 0.21 / 247.62 2 2
2 7 2004.56 45 14.28 2848 1830 2.04 / 249.45 2 2
3 13 1465.08 21 14.48 2180 663 2.70 / 250.11 2 2
4 13 1051.60 21 14.60 1652 507 3.21 / 250.62 2 2
5 13 466.96 21 14.85 948 296 3.50 / 250.92 2 2
6 8 0.28 170 15.04 336 859 4.36 / 251.77 2 4
Average= 4.27
(KJ/cycle)

Cycle 57 GMT 24/ 4/2019 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 28 15.00 482 202 0.20 / 243.36 2 2
2 3 1038.80 1 15.06 1766 27 0.23 / 243.39 2 2
3 7 2004.72 45 14.28 2828 1817 2.05 / 245.21 2 2
4 13 1471.68 21 14.48 2210 672 2.72 / 245.88 2 2
5 13 915.92 21 14.66 1507 464 3.18 / 246.34 2 2
6 13 215.00 21 14.98 636 200 3.38 / 246.54 2 2
7 8 -0.08 170 15.05 339 867 4.25 / 247.41 2 3
Average= 4.27
(KJ/cycle)

Cycle 56 GMT 14/ 4/2019 2:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 27 15.01 465 188 0.19 / 239.02 2 2
2 3 1036.48 1 15.09 1741 26 0.21 / 239.05 2 2
3 7 2006.44 45 14.28 2808 1804 2.02 / 240.85 2 2
4 13 1585.00 21 14.46 2330 708 2.73 / 241.56 2 2
5 13 1016.76 21 14.62 1627 500 3.23 / 242.06 2 2
6 13 311.00 21 14.94 753 236 3.46 / 242.29 2 2
7 8 0.32 170 15.05 339 867 4.33 / 243.16 2 3
Average= 4.27
(KJ/cycle)

Cycle 55 GMT 4/ 4/2019 2:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 25 15.01 463 174 0.17 / 234.60 2 2
2 3 1062.80 2 14.98 1761 53 0.23 / 234.65 2 2
3 7 2001.88 45 14.28 2850 1831 2.06 / 236.48 2 2
4 13 1589.84 21 14.45 2329 707 2.76 / 237.19 2 2
5 13 1011.68 21 14.64 1620 498 3.26 / 237.68 2 2
6 13 425.68 21 14.88 895 280 3.54 / 237.96 2 2
7 8 0.24 170 15.05 339 867 4.41 / 238.83 2 8
Average= 4.26
(KJ/cycle)

Cycle 54 GMT 25/ 3/2019 2:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 28 15.02 475 200 0.20 / 230.25 2 2
2 3 899.16 -2 15.47 0 0 0.00 / 230.25 2 2
3 7 2004.24 45 14.29 2811 1808 2.01 / 232.05 2 2
4 13 1585.52 21 14.44 2371 719 2.73 / 232.77 2 2
5 13 1015.04 21 14.63 1635 502 3.23 / 233.28 2 2
6 13 439.56 21 14.88 915 286 3.51 / 233.56 2 2
7 8 0.16 170 15.06 336 860 4.37 / 234.42 2 4
Average= 4.26
(KJ/cycle)

Cycle 53 GMT 15/ 3/2019 2: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 27 15.02 465 189 0.19 / 225.94 2 2
2 7 2005.52 45 14.28 2840 1825 2.01 / 227.76 2 2
3 13 1473.12 21 14.50 2179 664 2.68 / 228.43 2 2
4 13 1056.64 21 14.63 1679 516 3.19 / 228.94 2 2
5 13 328.08 21 14.94 776 243 3.44 / 229.19 2 2
6 8 0.20 170 15.06 336 860 4.30 / 230.05 2 2
Average= 4.26
(KJ/cycle)

Cycle 52 GMT 5/ 3/2019 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 28 15.02 467 196 0.20 / 221.66 2 2
2 7 2003.52 45 14.29 2858 1838 2.03 / 223.50 2 2
3 13 1472.80 21 14.50 2194 668 2.70 / 224.17 2 2
4 13 913.92 21 14.69 1503 464 3.17 / 224.63 2 2
5 13 358.24 21 14.93 818 256 3.42 / 224.89 2 2
6 8 0.00 170 15.06 338 865 4.29 / 225.75 2 3
Average= 4.26
(KJ/cycle)

Cycle 51 GMT 23/ 2/2019 1:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 27 15.02 467 189 0.19 / 217.33 2 2
2 7 2004.28 44 14.29 2855 1795 1.98 / 219.13 2 2
3 13 1592.00 21 14.47 2351 714 2.70 / 219.84 2 2
4 13 1036.12 21 14.64 1654 509 3.21 / 220.35 2 2
5 13 323.76 21 14.95 774 243 3.45 / 220.60 2 2
6 8 0.60 170 15.06 339 868 4.32 / 221.46 2 3
Average= 4.26
(KJ/cycle)

Cycle 50 GMT 13/ 2/2019 1:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 26 15.02 472 184 0.18 / 212.82 2 2
2 3 1040.64 1 15.06 1767 27 0.21 / 212.85 2 2
3 7 2005.52 43 14.30 2871 1765 1.98 / 214.61 2 2
4 13 1727.20 21 14.41 2515 761 2.74 / 215.38 2 2
5 13 1003.88 21 14.65 1611 496 3.23 / 215.87 2 2
6 13 435.60 21 14.90 915 286 3.52 / 216.16 2 2
7 13 27.00 21 15.09 384 122 3.64 / 216.28 2 2
8 8 -0.04 170 15.06 338 865 4.51 / 217.14 2 4
Average= 4.26
(KJ/cycle)

Cycle 49 GMT 3/ 2/2019 1:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 28 15.01 472 198 0.20 / 208.49 2 2
2 3 960.08 -1 15.48 0 0 0.00 / 208.49 2 2
3 7 2001.48 43 14.32 2811 1731 1.93 / 210.22 2 2
4 13 1719.36 21 14.42 2508 759 2.69 / 210.98 2 2
5 13 1001.60 21 14.66 1619 498 3.19 / 211.48 2 2
6 13 436.04 21 14.90 917 287 3.47 / 211.76 2 2
7 8 0.24 170 15.07 341 874 4.35 / 212.64 2 5
Average= 4.25
(KJ/cycle)

Cycle 48 GMT 24/ 1/2019 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 29 15.03 479 209 0.21 / 203.77 2 2
2 3 963.04 -1 15.48 0 0 0.00 / 203.77 2 2
3 7 2001.20 43 14.31 2840 1748 1.96 / 205.52 2 2
4 13 1590.32 21 14.48 2342 712 2.67 / 206.23 2 2
5 13 1160.24 21 14.60 1801 552 3.22 / 206.79 2 2
6 13 425.96 21 14.91 904 283 3.50 / 207.07 2 2
7 8 0.16 170 15.07 339 868 4.37 / 207.94 2 4
8 14 0.16 70 15.04 335 353 4.72 / 208.29 2 6
Average= 4.25
(KJ/cycle)

Cycle 47 GMT 14/ 1/2019 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 28 15.03 473 199 0.20 / 199.40 2 2
2 3 1027.04 1 15.13 1732 26 0.23 / 199.43 2 2
3 7 2006.44 43 14.31 2855 1757 1.98 / 201.19 2 2
4 13 1594.72 21 14.48 2340 712 2.69 / 201.90 2 2
5 13 1031.60 21 14.66 1644 506 3.20 / 202.40 2 2
6 13 456.88 21 14.90 935 293 3.49 / 202.70 2 2
7 8 -0.28 170 15.08 339 869 4.36 / 203.57 2 4
Average= 4.24
(KJ/cycle)

Cycle 46 GMT 4/ 1/2019 1:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 27 15.04 471 191 0.19 / 195.05 2 2
2 3 1025.64 1 15.14 1735 26 0.22 / 195.08 2 2
3 7 2001.28 43 14.33 2835 1747 1.96 / 196.83 2 2
4 13 1590.76 21 14.48 2354 716 2.68 / 197.54 2 2
5 13 1026.48 21 14.66 1647 507 3.19 / 198.05 2 2
6 13 439.72 21 14.91 917 287 3.47 / 198.34 2 2
7 8 0.12 170 15.08 338 866 4.34 / 199.20 2 9
Average= 4.24
(KJ/cycle)

Cycle 45 GMT 25/12/2018 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 27 15.04 467 190 0.19 / 190.67 2 2
2 7 2003.08 43 14.33 2822 1739 1.93 / 192.41 2 2
3 13 1719.36 21 14.45 2505 760 2.69 / 193.17 2 2
4 13 1141.28 21 14.62 1792 550 3.24 / 193.72 2 2
5 13 408.68 21 14.93 880 276 3.51 / 193.99 2 2
6 8 0.52 170 15.08 339 869 4.38 / 194.86 2 4
Average= 4.24
(KJ/cycle)

Cycle 44 GMT 15/12/2018 1:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 27 15.04 471 191 0.19 / 186.39 2 2
2 3 1022.96 1 15.14 1761 27 0.22 / 186.41 2 2
3 7 2006.00 43 14.33 2807 1730 1.95 / 188.14 2 2
4 13 1598.12 21 14.48 2351 715 2.66 / 188.86 2 2
5 13 1034.24 21 14.66 1650 508 3.17 / 189.37 2 2
6 13 340.00 21 14.96 789 248 3.42 / 189.61 2 2
7 8 -0.16 170 15.08 338 866 4.28 / 190.48 2 5
Average= 4.23
(KJ/cycle)

Cycle 43 GMT 5/12/2018 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 28 15.03 473 199 0.20 / 182.05 2 2
2 3 970.48 -1 15.49 0 0 0.00 / 182.05 2 2
3 7 2003.92 43 14.32 2851 1756 1.95 / 183.80 2 2
4 13 1593.40 21 14.50 2341 713 2.67 / 184.51 2 2
5 13 1036.72 21 14.67 1669 514 3.18 / 185.03 2 2
6 13 461.60 21 14.91 942 295 3.48 / 185.32 2 2
7 8 0.40 170 15.08 340 872 4.35 / 186.19 2 6
Average= 4.23
(KJ/cycle)

Cycle 42 GMT 25/11/2018 1:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 27 15.03 479 194 0.19 / 177.74 2 2
2 3 1040.48 1 15.08 1727 26 0.22 / 177.77 2 2
3 7 2002.92 43 14.34 2832 1746 1.97 / 179.51 2 2
4 13 1591.24 21 14.50 2352 716 2.68 / 180.23 2 2
5 13 1029.40 21 14.68 1649 508 3.19 / 180.74 2 2
6 13 315.44 21 14.99 755 238 3.43 / 180.98 2 2
7 8 -0.20 170 15.09 339 870 4.30 / 181.85 2 2
Average= 4.23
(KJ/cycle)

Cycle 41 GMT 15/11/2018 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 27 15.03 473 192 0.19 / 173.42 2 2
2 7 2001.80 43 14.34 2841 1752 1.94 / 175.17 2 2
3 13 1720.72 21 14.45 2512 762 2.71 / 175.93 2 2
4 13 1011.48 21 14.69 1625 501 3.21 / 176.44 2 2
5 13 316.36 21 14.98 757 238 3.45 / 176.67 2 2
6 8 0.28 170 15.09 341 875 4.32 / 177.55 2 2
Average= 4.23
(KJ/cycle)

Cycle 40 GMT 5/11/2018 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 27 15.04 476 193 0.19 / 169.07 2 2
2 7 2003.56 43 14.35 2817 1738 1.93 / 170.81 2 2
3 13 1599.20 21 14.49 2375 723 2.65 / 171.53 2 2
4 13 1043.40 21 14.67 1682 518 3.17 / 172.05 2 2
5 13 471.80 21 14.91 960 301 3.47 / 172.35 2 2
6 8 0.08 170 15.09 342 877 4.35 / 173.23 2 3
Average= 4.23
(KJ/cycle)

Cycle 39 GMT 26/10/2018 1:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 26 15.04 479 187 0.19 / 164.70 2 2
2 3 1033.92 1 15.13 1761 27 0.21 / 164.73 2 2
3 7 2003.84 43 14.35 2831 1747 1.96 / 166.48 2 2
4 13 1602.08 21 14.49 2353 716 2.68 / 167.19 2 2
5 13 1033.20 21 14.67 1656 510 3.19 / 167.70 2 2
6 13 458.96 21 14.92 944 296 3.48 / 168.00 2 2
7 8 0.04 170 15.09 342 877 4.36 / 168.88 2 4
Average= 4.22
(KJ/cycle)

Cycle 38 GMT 16/10/2018 1:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 26 15.03 484 189 0.19 / 160.43 2 2
2 7 2003.56 43 14.35 2857 1763 1.95 / 162.19 2 2
3 13 1587.88 21 14.50 2340 713 2.66 / 162.91 2 2
4 13 1013.88 21 14.69 1629 503 3.17 / 163.41 2 2
5 13 300.92 21 15.00 737 232 3.40 / 163.64 2 2
6 8 0.20 170 15.10 341 875 4.27 / 164.52 2 6
Average= 4.22
(KJ/cycle)

Cycle 37 GMT 6/10/2018 1: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 26 15.05 480 188 0.19 / 155.72 2 2
2 7 2004.76 43 14.36 2824 1744 1.93 / 157.47 2 2
3 13 1729.52 21 14.45 2523 766 2.70 / 158.23 2 2
4 13 1013.28 21 14.70 1610 497 3.19 / 158.73 2 2
5 13 432.12 21 14.94 902 283 3.48 / 159.01 2 2
6 8 -0.04 170 15.10 340 873 4.35 / 159.89 2 3
7 14 -0.04 70 15.06 338 356 4.71 / 160.24 2 3
Average= 4.22
(KJ/cycle)

Cycle 36 GMT 26/ 9/2018 0:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 27 15.05 480 195 0.20 / 151.40 2 2
2 7 2002.08 43 14.36 2846 1757 1.95 / 153.16 2 2
3 13 1725.24 21 14.46 2517 764 2.72 / 153.92 2 2
4 13 1004.92 21 14.70 1620 500 3.22 / 154.42 2 2
5 13 288.96 21 15.01 727 229 3.45 / 154.65 2 2
6 8 0.64 170 15.10 344 883 4.33 / 155.54 2 3
Average= 4.20
(KJ/cycle)

Cycle 35 GMT 16/ 9/2018 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 27 15.04 487 198 0.20 / 147.11 2 2
2 7 2004.44 43 14.36 2847 1758 1.96 / 148.87 2 2
3 13 1593.64 21 14.52 2331 711 2.67 / 149.58 2 2
4 13 1023.72 21 14.70 1641 507 3.17 / 150.09 2 2
5 13 317.48 21 15.00 761 240 3.41 / 150.33 2 2
6 8 -0.12 170 15.10 343 880 4.29 / 151.21 2 2
Average= 4.20
(KJ/cycle)

Cycle 34 GMT 6/ 9/2018 0:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 27 15.05 481 195 0.20 / 142.60 2 2
2 7 2003.44 44 14.36 2829 1787 1.98 / 144.39 2 2
3 13 1714.40 21 14.48 2503 761 2.74 / 145.15 2 2
4 13 986.52 21 14.72 1594 493 3.24 / 145.64 2 2
5 13 411.28 21 14.96 875 275 3.51 / 145.91 2 2
6 13 22.64 21 15.14 382 121 3.63 / 146.04 2 2
7 8 -0.04 170 15.10 342 878 4.51 / 146.91 2 3
Average= 4.20
(KJ/cycle)

Cycle 33 GMT 27/ 8/2018 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 27 15.05 488 198 0.20 / 138.25 2 2
2 7 2006.28 43 14.36 2853 1762 1.96 / 140.01 2 2
3 13 1598.20 21 14.52 2356 718 2.68 / 140.73 2 2
4 13 1025.72 21 14.70 1638 506 3.18 / 141.23 2 2
5 13 439.20 21 14.94 918 288 3.47 / 141.52 2 2
6 8 0.00 170 15.10 344 883 4.36 / 142.40 2 2
Average= 4.19
(KJ/cycle)

Cycle 32 GMT 17/ 8/2018 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 27 15.06 494 201 0.20 / 133.90 2 2
2 7 2006.24 43 14.37 2852 1762 1.96 / 135.66 2 2
3 13 1599.00 21 14.51 2373 723 2.69 / 136.38 2 2
4 13 1024.08 21 14.70 1632 504 3.19 / 136.89 2 2
5 13 430.92 21 14.95 904 284 3.47 / 137.17 2 2
6 8 0.48 170 15.11 341 876 4.35 / 138.05 2 6
Average= 4.18
(KJ/cycle)

Cycle 31 GMT 7/ 8/2018 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 27 15.07 476 194 0.19 / 129.41 2 2
2 3 1019.40 1 15.19 1742 26 0.22 / 129.44 2 2
3 7 2001.16 43 14.37 2849 1760 1.98 / 131.20 2 2
4 13 1719.24 21 14.49 2500 761 2.74 / 131.96 2 2
5 13 1124.12 21 14.67 1759 542 3.28 / 132.50 2 2
6 13 530.24 21 14.91 1032 323 3.61 / 132.82 2 2
7 8 -0.04 170 15.11 341 876 4.48 / 133.70 2 4
Average= 4.18
(KJ/cycle)

Cycle 30 GMT 28/ 7/2018 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 15.07 473 200 0.20 / 125.04 2 2
2 3 955.40 -1 15.51 0 0 0.00 / 125.04 2 2
3 7 2005.36 43 14.38 2849 1762 1.96 / 126.80 2 2
4 13 1585.28 21 14.53 2330 711 2.67 / 127.51 2 2
5 13 1143.00 21 14.66 1784 549 3.22 / 128.06 2 2
6 13 407.88 21 14.97 873 274 3.50 / 128.34 2 2
7 8 0.00 170 15.11 342 878 4.37 / 129.22 2 5
Average= 4.17
(KJ/cycle)

Cycle 29 GMT 18/ 7/2018 1: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 28 15.07 473 200 0.20 / 120.80 2 2
2 7 2003.40 43 14.38 2806 1735 1.93 / 122.54 2 2
3 13 1597.32 21 14.54 2328 711 2.65 / 123.25 2 2
4 13 917.52 21 14.76 1502 466 3.11 / 123.71 2 2
5 13 358.40 21 15.00 812 256 3.37 / 123.97 2 2
6 8 0.20 170 15.12 339 871 4.24 / 124.84 2 3
Average= 4.16
(KJ/cycle)

Cycle 28 GMT 8/ 7/2018 0:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 28 15.06 485 205 0.20 / 116.48 2 2
2 7 2001.80 43 14.40 2803 1736 1.94 / 118.22 2 2
3 13 1586.56 21 14.54 2356 719 2.66 / 118.94 2 2
4 13 1028.80 21 14.71 1646 508 3.17 / 119.44 2 2
5 13 431.08 21 14.96 903 284 3.45 / 119.73 2 2
6 8 0.28 170 15.12 341 877 4.33 / 120.60 2 4
Average= 4.16
(KJ/cycle)

Cycle 27 GMT 28/ 6/2018 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 27 15.08 484 197 0.20 / 111.94 2 2
2 3 1046.24 1 15.08 1753 26 0.22 / 111.97 2 2
3 7 2006.56 44 14.39 2821 1786 2.01 / 113.76 2 2
4 13 1602.12 21 14.53 2366 722 2.73 / 114.48 2 2
5 13 1025.68 21 14.71 1640 507 3.24 / 114.98 2 2
6 13 439.92 21 14.96 921 289 3.53 / 115.27 2 2
7 13 25.80 21 15.15 386 123 3.65 / 115.40 2 2
8 8 0.28 170 15.11 342 878 4.53 / 116.28 2 3
Average= 4.15
(KJ/cycle)

Cycle 26 GMT 18/ 6/2018 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 27 15.08 477 194 0.19 / 107.64 2 2
2 7 2004.60 43 14.39 2836 1755 1.95 / 109.40 2 2
3 13 1585.40 21 14.54 2337 714 2.66 / 110.11 2 2
4 13 1030.80 21 14.72 1647 509 3.17 / 110.62 2 2
5 13 326.92 21 15.02 777 245 3.42 / 110.87 2 2
6 8 0.04 170 15.13 342 880 4.30 / 111.75 2 3
Average= 4.14
(KJ/cycle)

Cycle 25 GMT 7/ 6/2018 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 27 15.08 466 190 0.19 / 103.44 2 2
2 7 2003.44 43 14.41 2815 1744 1.93 / 105.18 2 2
3 13 1472.88 21 14.60 2184 670 2.60 / 105.85 2 2
4 13 925.72 21 14.77 1511 469 3.07 / 106.32 2 2
5 13 360.44 21 15.00 813 256 3.33 / 106.58 2 2
6 8 0.00 170 15.13 340 875 4.20 / 107.45 2 4
Average= 4.13
(KJ/cycle)

Cycle 24 GMT 28/ 5/2018 23:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 28 15.09 472 199 0.20 / 99.03 2 2
2 3 972.20 -1 15.55 0 0 0.00 / 99.03 2 2
3 7 2003.32 43 14.40 2838 1757 1.96 / 100.78 2 2
4 13 1594.04 21 14.56 2352 719 2.68 / 101.50 2 2
5 13 1026.28 21 14.73 1655 512 3.19 / 102.01 2 2
6 13 309.36 21 15.03 748 236 3.42 / 102.25 2 2
7 13 36.04 21 15.16 393 125 3.55 / 102.38 2 2
8 8 0.12 170 15.13 339 872 4.42 / 103.25 2 4
Average= 4.13
(KJ/cycle)

Cycle 23 GMT 18/ 5/2018 23:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 28 15.10 479 203 0.20 / 94.67 2 2
2 3 1020.12 1 15.21 1767 27 0.23 / 94.70 2 2
3 7 2002.56 43 14.41 2826 1751 1.98 / 96.45 2 2
4 13 1589.40 21 14.56 2353 719 2.70 / 97.17 2 2
5 13 1016.48 21 14.74 1626 503 3.20 / 97.67 2 2
6 13 435.68 21 14.97 913 287 3.49 / 97.96 2 2
7 8 0.08 170 15.14 338 870 4.36 / 98.83 2 2
Average= 4.12
(KJ/cycle)

Cycle 22 GMT 8/ 5/2018 23:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 28 15.10 469 198 0.20 / 90.39 2 2
2 7 2003.16 43 14.42 2846 1765 1.96 / 92.15 2 2
3 13 1591.20 21 14.56 2340 715 2.68 / 92.87 2 2
4 13 1014.32 21 14.74 1616 500 3.18 / 93.37 2 2
5 13 302.40 21 15.04 740 234 3.41 / 93.60 2 2
6 8 0.24 170 15.15 336 865 4.28 / 94.47 2 3
Average= 4.11
(KJ/cycle)

Cycle 21 GMT 28/ 4/2018 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 28 15.10 472 200 0.20 / 86.10 2 2
2 7 2002.44 43 14.43 2823 1752 1.95 / 87.85 2 2
3 13 1589.60 21 14.56 2369 724 2.68 / 88.58 2 2
4 13 1018.04 21 14.74 1633 505 3.18 / 89.08 2 2
5 13 299.12 21 15.05 742 235 3.42 / 89.32 2 2
6 8 0.08 170 15.15 339 873 4.29 / 90.19 2 3
Average= 4.10
(KJ/cycle)

Cycle 20 GMT 18/ 4/2018 23:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 28 15.11 465 197 0.20 / 81.67 2 2
2 7 2005.12 43 14.42 2843 1763 1.96 / 83.43 2 2
3 13 1603.44 21 14.56 2379 727 2.69 / 84.16 2 2
4 13 1031.96 21 14.74 1647 510 3.20 / 84.67 2 2
5 13 317.36 21 15.04 759 240 3.44 / 84.91 2 2
6 13 38.52 21 15.17 394 126 3.56 / 85.03 2 2
7 8 -0.36 170 15.14 337 867 4.43 / 85.90 2 6
Average= 4.09
(KJ/cycle)

Cycle 19 GMT 8/ 4/2018 22:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 28 15.11 473 200 0.20 / 77.22 2 2
2 3 1018.72 1 15.22 1760 27 0.23 / 77.25 2 2
3 7 2003.56 43 14.43 2845 1765 1.99 / 79.02 2 2
4 13 1728.92 21 14.53 2514 767 2.76 / 79.78 2 2
5 13 1139.48 21 14.70 1778 549 3.31 / 80.33 2 2
6 13 393.08 21 15.01 858 270 3.58 / 80.60 2 2
7 8 0.44 170 15.15 337 868 4.45 / 81.47 2 6
Average= 4.07
(KJ/cycle)

Cycle 18 GMT 29/ 3/2018 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 27 15.12 471 192 0.19 / 72.93 2 2
2 7 2005.24 43 14.44 2826 1755 1.95 / 74.68 2 2
3 13 1590.84 21 14.57 2344 717 2.66 / 75.40 2 2
4 13 1018.60 21 14.75 1649 511 3.17 / 75.91 2 2
5 13 306.12 21 15.05 750 237 3.41 / 76.15 2 2
6 8 0.12 170 15.15 340 876 4.29 / 77.02 2 3
Average= 4.05
(KJ/cycle)

Cycle 17 GMT 19/ 3/2018 22:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 27 15.12 462 189 0.19 / 68.60 2 2
2 7 2004.68 44 14.44 2829 1797 1.99 / 70.39 2 2
3 13 1584.24 21 14.58 2344 718 2.70 / 71.11 2 2
4 13 885.24 21 14.80 1478 459 3.16 / 71.57 2 2
5 13 446.68 21 14.98 933 294 3.46 / 71.87 2 2
6 8 0.04 170 15.16 338 871 4.33 / 72.74 2 8
Average= 4.04
(KJ/cycle)

Cycle 16 GMT 9/ 3/2018 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 27 15.13 462 189 0.19 / 64.16 2 2
2 7 2003.56 43 14.45 2825 1755 1.94 / 65.92 2 2
3 13 1724.36 21 14.55 2516 769 2.71 / 66.68 2 2
4 13 1005.40 21 14.76 1615 501 3.21 / 67.18 2 2
5 13 286.36 21 15.07 718 227 3.44 / 67.41 2 2
6 13 30.80 21 15.19 386 123 3.56 / 67.54 2 2
7 8 -0.08 170 15.15 339 873 4.44 / 68.41 2 6
Average= 4.02
(KJ/cycle)

Cycle 15 GMT 27/ 2/2018 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 28 15.13 467 198 0.20 / 59.72 2 2
2 7 2001.84 43 14.44 2858 1775 1.97 / 61.49 2 2
3 13 1592.00 21 14.59 2324 712 2.68 / 62.21 2 2
4 13 1012.12 21 14.77 1617 502 3.19 / 62.71 2 2
5 13 411.92 21 15.01 876 276 3.46 / 62.98 2 2
6 13 22.20 21 15.19 375 120 3.58 / 63.10 2 2
7 8 0.20 170 15.16 337 869 4.45 / 63.97 2 3
Average= 4.00
(KJ/cycle)

Cycle 14 GMT 17/ 2/2018 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 27 15.12 476 194 0.19 / 55.47 2 2
2 7 2003.32 43 14.45 2849 1770 1.96 / 57.24 2 2
3 13 1582.72 21 14.59 2361 723 2.69 / 57.96 2 2
4 13 885.60 21 14.81 1472 458 3.15 / 58.42 2 2
5 13 326.04 21 15.05 771 244 3.39 / 58.67 2 2
6 8 0.12 170 15.17 332 856 4.25 / 59.52 2 2
Average= 3.97
(KJ/cycle)

Cycle 13 GMT 7/ 2/2018 21: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 28 15.12 473 200 0.20 / 51.06 2 2
2 7 2002.36 43 14.46 2847 1770 1.97 / 52.83 2 2
3 13 1596.08 20 14.61 2337 683 2.65 / 53.51 2 2
4 13 1023.88 20 14.77 1636 483 3.14 / 53.99 2 2
5 13 456.12 20 15.00 950 285 3.42 / 54.28 2 2
6 13 31.52 20 15.19 393 119 3.54 / 54.40 2 2
7 8 0.08 170 15.16 341 879 4.42 / 55.28 2 3
Average= 3.95
(KJ/cycle)

Cycle 12 GMT 28/ 1/2018 20:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 28 15.13 475 201 0.20 / 46.77 2 2
2 7 2003.84 44 14.45 2858 1817 2.02 / 48.59 2 2
3 13 1462.52 20 14.64 2192 642 2.66 / 49.23 2 2
4 13 908.36 20 14.82 1507 447 3.11 / 49.68 2 2
5 13 220.68 20 15.12 640 194 3.30 / 49.87 2 2
6 13 20.96 20 15.20 378 115 3.42 / 49.98 2 2
7 8 0.00 170 15.17 338 872 4.29 / 50.86 2 5
Average= 3.91
(KJ/cycle)

Cycle 11 GMT 18/ 1/2018 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 15.14 476 202 0.20 / 42.45 2 2
2 3 1023.60 1 15.25 1746 27 0.23 / 42.48 2 2
3 7 2003.96 43 14.47 2856 1777 2.01 / 44.26 2 2
4 13 1598.76 20 14.62 2339 684 2.69 / 44.94 2 2
5 13 1029.68 20 14.78 1632 482 3.17 / 45.42 2 2
6 13 447.76 20 15.01 932 280 3.45 / 45.70 2 2
7 8 0.04 170 15.17 336 867 4.32 / 46.57 2 2
Average= 3.88
(KJ/cycle)

Cycle 10 GMT 8/ 1/2018 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 27 15.13 470 192 0.19 / 38.14 2 2
2 7 2001.88 44 14.46 2861 1820 2.01 / 39.96 2 2
3 13 1573.48 20 14.62 2336 683 2.70 / 40.64 2 2
4 13 1002.24 20 14.80 1607 476 3.17 / 41.12 2 2
5 13 424.24 20 15.02 894 269 3.44 / 41.38 2 2
6 8 -0.40 170 15.18 336 867 4.31 / 42.25 2 6
Average= 3.84
(KJ/cycle)

Cycle 9 GMT 29/12/2017 19:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 26 15.14 469 185 0.18 / 33.87 2 2
2 3 1043.40 1 15.18 1740 26 0.21 / 33.90 2 2
3 7 2005.08 43 14.49 2829 1763 1.97 / 35.66 2 2
4 13 1599.68 20 14.61 2371 693 2.67 / 36.35 2 2
5 13 1030.56 20 14.79 1648 487 3.15 / 36.84 2 2
6 13 323.36 20 15.08 765 231 3.38 / 37.07 2 2
7 8 0.12 170 15.18 338 872 4.26 / 37.94 2 3
Average= 3.79
(KJ/cycle)

Cycle 8 GMT 19/12/2017 18:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 26 15.14 464 183 0.18 / 29.65 2 2
2 7 2003.96 44 14.47 2856 1818 2.00 / 31.47 2 2
3 13 1459.20 22 14.65 2172 700 2.70 / 32.17 2 2
4 13 897.00 22 14.83 1473 481 3.18 / 32.65 2 2
5 13 175.60 22 15.14 578 193 3.37 / 32.84 2 2
6 8 0.04 165 15.18 338 847 4.22 / 33.69 2 2
Average= 3.74
(KJ/cycle)

Cycle 7 GMT 9/12/2017 18:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 25 15.14 470 178 0.18 / 25.36 2 2
2 3 1026.40 1 15.24 1719 26 0.20 / 25.39 2 2
3 7 2002.96 44 14.48 2856 1820 2.02 / 27.21 2 2
4 13 1451.84 22 14.66 2146 692 2.72 / 27.90 2 2
5 13 893.68 22 14.83 1467 479 3.19 / 28.38 2 2
6 13 304.56 22 15.08 739 245 3.44 / 28.62 2 2
7 8 0.40 165 15.18 337 844 4.28 / 29.47 2 5
Average= 3.68
(KJ/cycle)

Cycle 6 GMT 29/11/2017 17:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 26 15.14 464 183 0.18 / 21.14 2 2
2 3 972.28 -1 15.58 0 0 0.00 / 21.14 2 2
3 3 1022.08 1 15.28 1766 27 0.21 / 21.16 2 2
4 7 2002.84 44 14.49 2821 1799 2.01 / 22.96 2 2
5 13 1463.28 22 14.66 2172 701 2.71 / 23.66 2 2
6 13 912.28 22 14.83 1483 484 3.19 / 24.15 2 2
7 13 197.52 22 15.13 596 198 3.39 / 24.34 2 2
8 8 0.08 165 15.18 335 839 4.23 / 25.18 2 2
Average= 3.60
(KJ/cycle)

Cycle 5 GMT 19/11/2017 17: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 23 15.16 473 165 0.16 / 16.76 2 2
2 10 1021.72 3 14.99 1693 76 0.24 / 16.83 2 2
3 7 2000.84 44 14.49 2841 1811 2.05 / 18.65 2 2
4 13 1590.12 22 14.63 2327 749 2.80 / 19.39 2 2
5 13 885.12 22 14.84 1453 474 3.28 / 19.87 2 2
6 13 303.20 22 15.08 729 242 3.52 / 20.11 2 2
7 8 0.20 165 15.18 336 842 4.36 / 20.95 2 6
Average= 3.49
(KJ/cycle)

Cycle 4 GMT 9/11/2017 16:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 27 15.14 472 193 0.19 / 13.08 2 2
2 3 931.52 -1 15.58 0 0 0.00 / 13.08 2 2
3 7 1507.72 44 14.71 2247 1454 1.65 / 14.54 2 2
4 13 1379.64 22 14.75 2079 675 2.32 / 15.21 2 2
5 13 676.12 22 14.97 1200 395 2.72 / 15.61 2 2
6 13 111.20 22 15.20 483 162 2.88 / 15.77 2 2
7 8 0.04 165 15.21 328 823 3.70 / 16.59 2 5
Average= 3.32
(KJ/cycle)

Cycle 3 GMT 8/11/2017 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 26 15.14 469 185 0.18 / 9.32 2 2
2 7 1514.60 44 14.70 2243 1451 1.64 / 10.77 2 2
3 13 1393.96 22 14.74 2113 685 2.32 / 11.45 2 2
4 13 808.88 22 14.90 1368 448 2.77 / 11.90 2 2
5 13 93.28 22 15.21 460 154 2.92 / 12.05 2 2
6 8 0.12 165 15.20 334 838 3.76 / 12.89 2 2
Average= 3.22
(KJ/cycle)

Cycle 2 GMT 7/11/2017 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 24 15.15 465 169 0.17 / 5.09 2 2
2 10 1008.32 3 15.03 1681 76 0.24 / 5.17 2 2
3 7 1506.80 74 14.62 2232 2415 2.66 / 7.58 2 2
4 13 456.92 25 15.03 928 349 3.01 / 7.93 2 2
5 8 0.12 240 15.18 329 1199 4.21 / 9.13 2 3
Average= 3.04
(KJ/cycle)

Cycle 1 GMT 6/11/2017 19:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 25 15.31 464 178 0.18 / 1.98 2 2
2 7 1001.80 74 14.81 1593 1746 1.92 / 3.72 2 2
3 8 0.88 240 15.21 329 1201 3.12 / 4.92 2 10
Average= 2.46
(KJ/cycle)

Cycle 0 GMT 6/11/2017 7:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 86.96 25 15.49 437 169 0.17 / 0.17 2 2
2 7 96.80 74 15.45 439 502 0.67 / 0.67 2 2
3 8 0.04 240 15.42 305 1129 1.80 / 1.80 2 6
Average= 1.80
(KJ/cycle)