SIO Argo Site:
Pump Diagnostics Page   



Serial= 4025 WMO= 2903831

Return

←PreviousNext→

Cycle 16 GMT 8/ 5/2025 21:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 47 14.76 431 299 0.30 / 62.33 3 3
2 8 2006.16 58 14.45 2858 2395 2.69 / 64.72 2 3
3 14 1633.36 30 14.46 2396 1039 3.73 / 65.76 2 4
4 14 1058.64 30 14.61 1674 734 4.47 / 66.50 2 6
5 14 524.88 30 14.76 985 436 4.90 / 66.93 2 6
6 14 183.80 30 14.84 534 238 5.14 / 67.17 2 7
7 14 112.60 30 14.85 429 191 5.33 / 67.36 2 8
8 14 50.20 30 14.84 337 150 5.48 / 67.51 2 9
9 9 -0.04 165 14.84 258 632 6.11 / 68.14 2 53
10 15 -0.08 55 14.83 199 162 6.28 / 68.31 33 245
Average= 6.21
(KJ/cycle)

Cycle 15 GMT 28/ 4/2025 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 47 14.76 422 293 0.29 / 55.90 3 3
2 8 1917.68 100 14.42 2737 3947 4.24 / 59.85 2 4
3 14 851.80 25 14.68 1413 519 4.76 / 60.37 2 6
4 14 388.68 25 14.81 803 297 5.06 / 60.66 2 6
5 14 146.32 25 14.86 478 178 5.23 / 60.84 2 6
6 14 109.72 25 14.86 425 158 5.39 / 61.00 2 6
7 14 78.60 25 14.84 377 140 5.53 / 61.14 2 7
8 14 27.20 25 14.84 305 113 5.64 / 61.25 2 8
9 9 0.00 159 14.83 256 604 6.25 / 61.86 3 55
10 15 -0.08 61 14.83 194 175 6.42 / 62.03 34 245
Average= 6.20
(KJ/cycle)

Cycle 14 GMT 27/ 4/2025 20: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 45 14.82 416 277 0.28 / 49.35 3 3
2 11 1019.64 2 14.92 1688 50 0.33 / 49.40 2 3
3 8 2007.60 100 14.32 2845 4074 4.40 / 53.47 2 4
4 14 787.76 25 14.68 1326 487 4.89 / 53.96 2 7
5 14 351.20 25 14.80 757 280 5.17 / 54.24 2 6
6 14 138.44 25 14.85 468 174 5.34 / 54.41 2 6
7 14 105.80 25 14.85 416 154 5.50 / 54.57 2 6
8 14 73.88 25 14.84 372 138 5.63 / 54.71 2 8
9 14 41.24 25 14.83 322 119 5.75 / 54.83 2 9
10 9 0.08 159 14.83 256 604 6.36 / 55.43 2 50
11 15 -0.08 61 14.81 196 177 6.53 / 55.61 29 245
Average= 6.18
(KJ/cycle)

Cycle 13 GMT 27/ 4/2025 7:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 45 14.79 415 276 0.28 / 45.47 3 3
2 3 1046.44 1 14.93 1735 26 0.30 / 45.49 2 3
3 3 1025.08 1 14.98 1691 25 0.33 / 45.52 2 3
4 8 1013.84 100 14.74 1589 2342 2.67 / 47.86 2 5
5 14 122.76 25 14.90 438 163 2.83 / 48.02 2 5
6 14 88.84 25 14.89 391 146 2.98 / 48.17 2 6
7 14 54.28 25 14.89 337 125 3.10 / 48.29 2 7
8 9 0.60 172 14.87 250 639 3.74 / 48.93 2 52
9 15 -0.20 48 14.85 196 140 3.88 / 49.07 33 245
Average= 6.13
(KJ/cycle)

Cycle 12 GMT 27/ 4/2025 1:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 46 14.77 421 286 0.29 / 39.05 3 3
2 8 1913.24 101 14.43 2732 3982 4.27 / 43.04 2 5
3 14 847.08 25 14.70 1405 516 4.78 / 43.55 2 7
4 14 383.80 25 14.83 792 294 5.08 / 43.85 2 6
5 14 153.16 25 14.88 482 179 5.26 / 44.03 2 6
6 14 110.76 25 14.87 415 154 5.41 / 44.18 2 6
7 14 77.20 25 14.87 369 137 5.55 / 44.32 2 7
8 14 42.72 25 14.86 317 118 5.67 / 44.43 2 8
9 9 0.00 157 14.85 249 581 6.25 / 45.01 2 52
10 15 -0.08 63 14.84 187 175 6.42 / 45.19 30 245
Average= 6.46
(KJ/cycle)

Cycle 11 GMT 26/ 4/2025 2:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 46 14.80 410 279 0.28 / 32.65 3 3
2 3 1017.76 1 14.98 1675 25 0.30 / 32.67 2 3
3 8 1915.96 100 14.44 2733 3946 4.25 / 36.62 2 4
4 14 846.88 25 14.69 1395 512 4.76 / 37.13 2 6
5 14 387.32 25 14.82 793 294 5.06 / 37.43 2 6
6 14 149.16 25 14.86 470 175 5.23 / 37.60 2 6
7 14 117.88 25 14.87 424 158 5.39 / 37.76 2 6
8 14 75.80 25 14.85 364 135 5.52 / 37.89 2 7
9 14 41.84 25 14.85 316 117 5.64 / 38.01 2 9
10 9 0.04 159 14.85 248 586 6.23 / 38.60 2 54
11 15 -0.04 61 14.84 191 173 6.40 / 38.77 32 245
Average= 6.46
(KJ/cycle)

Cycle 10 GMT 25/ 4/2025 3:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 46 14.84 415 283 0.28 / 26.32 3 3
2 8 1913.16 100 14.44 2719 3926 4.21 / 30.24 2 3
3 14 842.76 25 14.70 1387 510 4.72 / 30.75 2 6
4 14 384.72 25 14.83 790 293 5.01 / 31.05 2 6
5 14 143.60 25 14.88 466 173 5.19 / 31.22 2 6
6 14 103.56 25 14.88 408 152 5.34 / 31.37 2 6
7 14 69.08 25 14.86 357 133 5.47 / 31.50 2 7
8 14 25.12 25 14.85 293 109 5.58 / 31.61 2 8
9 9 0.04 159 14.85 247 583 6.16 / 32.20 2 52
10 15 -0.16 61 14.84 191 173 6.33 / 32.37 32 245
Average= 6.47
(KJ/cycle)

Cycle 9 GMT 24/ 4/2025 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 45 14.85 403 269 0.27 / 19.53 3 3
2 8 1724.64 145 14.47 2480 5203 5.47 / 24.73 2 4
3 14 166.60 16 14.91 494 118 5.59 / 24.85 2 5
4 14 125.36 16 14.91 435 104 5.69 / 24.95 2 5
5 14 104.00 16 14.90 399 95 5.79 / 25.05 2 5
6 14 86.52 16 14.90 372 89 5.88 / 25.14 2 5
7 14 61.44 16 14.90 338 81 5.96 / 25.22 2 6
8 14 37.64 16 14.88 298 71 6.03 / 25.29 2 7
9 9 0.04 176 14.88 238 623 6.65 / 25.91 2 60
10 15 -0.04 44 14.86 187 122 6.78 / 26.03 38 245
Average= 6.51
(KJ/cycle)

Cycle 8 GMT 23/ 4/2025 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 45 14.81 403 269 0.27 / 13.28 3 3
2 8 1521.04 145 14.57 2225 4701 4.97 / 17.98 2 5
3 14 155.88 16 14.92 478 114 5.08 / 18.09 2 5
4 14 122.36 16 14.91 429 102 5.19 / 18.20 2 5
5 14 106.68 16 14.91 400 95 5.28 / 18.29 2 5
6 14 85.08 16 14.91 366 87 5.37 / 18.38 2 6
7 14 56.16 16 14.90 327 78 5.45 / 18.46 2 6
8 14 32.92 16 14.90 292 70 5.52 / 18.53 2 7
9 9 0.08 170 14.90 235 595 6.11 / 19.12 3 56
10 15 -0.04 50 14.89 183 136 6.25 / 19.26 34 245
Average= 6.42
(KJ/cycle)

Cycle 7 GMT 22/ 4/2025 8:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 45 14.86 409 273 0.27 / 7.06 3 3
2 8 1513.48 145 14.54 2213 4666 4.94 / 11.73 2 5
3 14 158.84 16 14.92 486 116 5.06 / 11.84 2 5
4 14 121.12 16 14.92 430 103 5.16 / 11.94 2 5
5 14 105.60 16 14.92 402 96 5.25 / 12.04 2 5
6 14 82.88 16 14.93 367 88 5.34 / 12.13 2 5
7 14 56.24 16 14.91 328 78 5.42 / 12.21 2 6
8 14 34.40 16 14.92 295 70 5.49 / 12.28 2 7
9 9 0.12 172 14.91 235 603 6.09 / 12.88 2 56
10 15 -0.08 48 14.89 184 132 6.22 / 13.01 34 245
Average= 6.51
(KJ/cycle)

Cycle 6 GMT 21/ 4/2025 22: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 45 15.23 400 274 0.27 / 2.56 3 3
2 8 985.80 145 14.76 1534 3283 3.56 / 5.85 2 6
3 14 73.88 16 14.92 369 88 3.65 / 5.93 2 6
4 14 44.28 16 14.90 326 78 3.72 / 6.01 2 8
5 9 0.04 176 14.90 246 645 4.37 / 6.66 2 51
6 15 -0.04 44 14.88 198 130 4.50 / 6.79 26 245
Average= 6.79
(KJ/cycle)

Cycle 0 GMT 21/ 4/2025 9: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 212.3 45 15.28 526 362 0.36 / 0.36 3 3
2 8 239.9 145 15.20 532 1173 1.53 / 1.53 3 4
3 14 40.6 16 15.12 271 66 1.60 / 1.60 3 4
4 9 0.2 187 15.07 214 603 2.20 / 2.20 3 54
5 15 0.1 33 15.04 173 86 2.29 / 2.29 41 245
Average= 2.29
(KJ/cycle)