SIO Argo Site:
Pump Diagnostics Page   



Serial= 4015 WMO= 1902373

Return

←PreviousNext→

Cycle 7 GMT 4/ 5/2025 17:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 36 14.80 403 215 0.21 / 38.61 3 3
2 8 1013.32 59 14.94 1571 1385 1.60 / 40.00 2 7
3 14 503.60 30 14.99 933 420 2.02 / 40.42 2 5
4 14 160.72 30 14.99 478 215 2.23 / 40.63 2 6
5 14 91.08 30 15.00 384 173 2.41 / 40.81 2 7
6 14 46.12 30 14.98 317 142 2.55 / 40.95 2 9
7 9 0.20 159 14.96 249 592 3.14 / 41.54 2 53
8 15 0.04 61 14.95 204 186 3.33 / 41.73 39 246
Average= 5.22
(KJ/cycle)

Cycle 6 GMT 24/ 4/2025 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 39 14.82 395 228 0.23 / 31.93 3 3
2 3 934.44 -1 15.34 1 0 0.00 / 31.93 3 3
3 3 960.48 -1 15.35 1 0 0.00 / 31.93 3 3
4 8 1735.44 145 14.36 2458 5118 5.35 / 37.05 2 5
5 14 173.72 25 14.87 496 184 5.53 / 37.23 2 6
6 14 106.96 25 14.87 408 152 5.68 / 37.39 2 7
7 14 76.28 25 14.86 362 134 5.82 / 37.52 2 8
8 14 28.84 25 14.86 293 109 5.93 / 37.63 2 9
9 9 0.24 157 14.85 249 581 6.51 / 38.21 2 54
10 15 0.08 63 14.84 203 190 6.70 / 38.40 40 246
Average= 5.49
(KJ/cycle)

Cycle 5 GMT 23/ 4/2025 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 40 14.81 397 235 0.24 / 25.26 3 3
2 3 909.28 -2 15.35 0 0 0.00 / 25.26 3 3
3 3 956.88 -1 15.35 1 0 0.00 / 25.26 3 3
4 8 1736.40 145 14.35 2455 5108 5.34 / 30.37 2 6
5 14 174.00 25 14.87 498 185 5.53 / 30.55 2 6
6 14 103.92 25 14.88 402 150 5.68 / 30.70 2 7
7 14 68.96 25 14.86 351 130 5.81 / 30.83 2 9
8 14 26.92 25 14.87 289 107 5.92 / 30.94 2 10
9 9 -0.36 155 14.87 247 569 6.49 / 31.51 2 52
10 15 -0.48 65 14.85 200 193 6.68 / 31.70 38 246
Average= 5.28
(KJ/cycle)

Cycle 4 GMT 22/ 4/2025 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 42 14.85 394 246 0.25 / 18.62 3 3
2 3 861.28 -3 15.37 1 0 0.00 / 18.62 3 3
3 3 926.24 -1 15.37 1 0 0.00 / 18.62 3 3
4 8 1701.92 146 14.46 2409 5086 5.33 / 23.70 2 7
5 14 160.68 25 14.90 478 178 5.51 / 23.88 2 6
6 14 98.24 25 14.91 390 145 5.65 / 24.03 2 7
7 14 66.40 25 14.90 343 128 5.78 / 24.16 2 8
8 14 23.80 25 14.89 284 106 5.89 / 24.26 2 10
9 9 0.20 155 14.89 247 570 6.46 / 24.83 2 50
10 15 0.04 65 14.88 200 193 6.65 / 25.02 37 246
Average= 5.00
(KJ/cycle)

Cycle 3 GMT 21/ 4/2025 19:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 45 14.88 387 259 0.26 / 12.58 3 3
2 3 797.64 -4 15.38 1 0 0.00 / 12.58 3 3
3 3 832.36 -3 15.39 1 0 0.00 / 12.58 3 3
4 8 1518.56 145 14.57 2181 4608 4.87 / 17.19 2 5
5 14 120.52 16 14.94 419 100 4.97 / 17.29 2 5
6 14 97.64 16 14.95 387 93 5.06 / 17.38 2 5
7 14 75.92 16 14.93 351 84 5.14 / 17.47 2 5
8 14 51.64 16 14.94 312 75 5.22 / 17.54 2 6
9 14 31.68 16 14.93 287 69 5.29 / 17.61 2 7
10 9 0.80 174 14.93 240 623 5.91 / 18.23 2 52
11 15 0.64 46 14.91 205 141 6.05 / 18.37 40 246
Average= 4.59
(KJ/cycle)

Cycle 2 GMT 20/ 4/2025 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 45 14.87 389 260 0.26 / 6.56 3 3
2 3 785.76 -4 15.39 0 0 0.00 / 6.56 3 3
3 3 817.36 -3 15.40 0 0 0.00 / 6.56 3 3
4 8 1513.04 145 14.53 2172 4576 4.84 / 11.13 2 6
5 14 122.80 16 14.93 422 101 4.94 / 11.23 2 5
6 14 97.60 16 14.93 386 92 5.03 / 11.33 2 5
7 14 79.60 16 14.93 359 86 5.12 / 11.41 2 5
8 14 55.60 16 14.92 325 78 5.19 / 11.49 2 6
9 14 32.64 16 14.92 289 69 5.26 / 11.56 2 7
10 9 0.24 176 14.92 239 628 5.89 / 12.19 2 52
11 15 0.08 44 14.90 207 136 6.03 / 12.32 40 246
Average= 4.11
(KJ/cycle)

Cycle 1 GMT 20/ 4/2025 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 45 15.02 379 256 0.26 / 2.41 3 3
2 3 771.36 -4 15.43 1 0 0.00 / 2.41 3 3
3 3 803.68 -4 15.42 1 0 0.00 / 2.41 3 3
4 8 866.16 145 14.85 1367 2943 3.20 / 5.36 2 8
5 14 64.48 16 14.98 338 81 3.28 / 5.44 2 6
6 14 38.56 16 14.97 303 73 3.35 / 5.51 2 7
7 9 0.36 178 14.95 245 652 4.01 / 6.16 2 56
8 15 0.16 42 14.93 214 134 4.14 / 6.30 41 246
Average= 3.15
(KJ/cycle)

Cycle 0 GMT 20/ 4/2025 5: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 193.76 45 15.32 481 332 0.33 / 0.33 3 3
2 8 218.96 145 15.26 493 1091 1.42 / 1.42 3 4
3 14 25.80 16 15.20 242 59 1.48 / 1.48 3 4
4 9 0.16 170 15.15 211 543 2.02 / 2.02 3 50
5 15 -0.16 50 15.12 176 133 2.16 / 2.16 41 246
Average= 2.16
(KJ/cycle)