SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 34 | 14.95 | 441 | 224 | 0.22 / 628.28 | 2 | 3 |
2 | 7 | 2011.56 | 31 | 14.75 | 2936 | 1342 | 1.57 / 629.63 | 2 | 2 |
3 | 13 | 1724.68 | 18 | 14.74 | 2594 | 688 | 2.25 / 630.32 | 2 | 3 |
4 | 13 | 1138.60 | 18 | 14.79 | 1849 | 492 | 2.75 / 630.81 | 2 | 3 |
5 | 13 | 707.48 | 18 | 14.86 | 1281 | 343 | 3.09 / 631.15 | 2 | 3 |
6 | 13 | 59.28 | 18 | 15.01 | 387 | 105 | 3.19 / 631.25 | 2 | 3 |
7 | 8 | 0.24 | 165 | 14.98 | 298 | 737 | 3.93 / 631.99 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 34 | 14.95 | 450 | 229 | 0.23 / 624.34 | 2 | 3 |
2 | 7 | 2014.80 | 32 | 14.76 | 2931 | 1384 | 1.61 / 625.73 | 2 | 2 |
3 | 13 | 1735.04 | 18 | 14.74 | 2592 | 688 | 2.30 / 626.41 | 2 | 3 |
4 | 13 | 1165.60 | 18 | 14.78 | 1868 | 497 | 2.80 / 626.91 | 2 | 3 |
5 | 13 | 593.32 | 18 | 14.89 | 1115 | 299 | 3.10 / 627.21 | 2 | 3 |
6 | 13 | 49.76 | 18 | 15.00 | 386 | 104 | 3.20 / 627.31 | 2 | 3 |
7 | 8 | 0.12 | 165 | 14.97 | 302 | 746 | 3.95 / 628.06 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 34 | 14.94 | 453 | 230 | 0.23 / 620.59 | 2 | 3 |
2 | 7 | 2006.76 | 31 | 14.78 | 2931 | 1343 | 1.57 / 621.93 | 2 | 2 |
3 | 13 | 1636.92 | 18 | 14.78 | 2474 | 658 | 2.23 / 622.59 | 2 | 3 |
4 | 13 | 1217.16 | 18 | 14.79 | 1940 | 516 | 2.75 / 623.10 | 2 | 3 |
5 | 13 | 532.92 | 18 | 14.91 | 1033 | 277 | 3.02 / 623.38 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.99 | 296 | 732 | 3.76 / 624.11 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 34 | 14.95 | 453 | 230 | 0.23 / 616.69 | 2 | 2 |
2 | 7 | 2013.56 | 31 | 14.79 | 2927 | 1342 | 1.57 / 618.04 | 2 | 3 |
3 | 13 | 1639.96 | 18 | 14.76 | 2485 | 660 | 2.23 / 618.70 | 2 | 3 |
4 | 13 | 1217.60 | 18 | 14.79 | 1939 | 516 | 2.75 / 619.21 | 2 | 3 |
5 | 13 | 646.64 | 18 | 14.88 | 1177 | 315 | 3.06 / 619.53 | 2 | 4 |
6 | 13 | 81.40 | 18 | 15.01 | 413 | 112 | 3.18 / 619.64 | 2 | 3 |
7 | 8 | 0.12 | 165 | 14.99 | 290 | 717 | 3.89 / 620.36 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 33 | 14.95 | 454 | 224 | 0.22 / 612.90 | 2 | 2 |
2 | 7 | 2010.44 | 31 | 14.78 | 2926 | 1341 | 1.56 / 614.24 | 2 | 2 |
3 | 13 | 1721.00 | 18 | 14.76 | 2590 | 688 | 2.25 / 614.93 | 2 | 3 |
4 | 13 | 1274.96 | 18 | 14.79 | 2006 | 534 | 2.79 / 615.47 | 2 | 3 |
5 | 13 | 538.80 | 18 | 14.91 | 1034 | 278 | 3.06 / 615.74 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.01 | 291 | 721 | 3.78 / 616.46 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 33 | 14.98 | 462 | 228 | 0.23 / 609.04 | 2 | 3 |
2 | 7 | 2005.84 | 31 | 14.78 | 2913 | 1335 | 1.56 / 610.37 | 2 | 2 |
3 | 13 | 1605.84 | 18 | 14.78 | 2445 | 650 | 2.21 / 611.02 | 2 | 3 |
4 | 13 | 1157.88 | 18 | 14.81 | 1861 | 496 | 2.71 / 611.52 | 2 | 3 |
5 | 13 | 709.32 | 18 | 14.88 | 1264 | 339 | 3.05 / 611.86 | 2 | 3 |
6 | 13 | 26.68 | 18 | 15.03 | 332 | 90 | 3.14 / 611.95 | 2 | 3 |
7 | 8 | 0.28 | 165 | 15.00 | 296 | 733 | 3.87 / 612.68 | 2 | 9 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 33 | 14.99 | 451 | 223 | 0.22 / 605.01 | 2 | 3 |
2 | 7 | 2008.24 | 31 | 14.80 | 2927 | 1343 | 1.57 / 606.35 | 2 | 2 |
3 | 13 | 1737.72 | 18 | 14.77 | 2624 | 698 | 2.26 / 607.05 | 2 | 3 |
4 | 13 | 1158.96 | 18 | 14.82 | 1870 | 499 | 2.76 / 607.55 | 2 | 3 |
5 | 13 | 726.64 | 18 | 14.89 | 1290 | 346 | 3.11 / 607.89 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.02 | 305 | 756 | 3.86 / 608.65 | 2 | 5 |
7 | 14 | 0.08 | 35 | 14.99 | 306 | 161 | 4.02 / 608.81 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 33 | 14.97 | 451 | 223 | 0.22 / 600.92 | 2 | 2 |
2 | 7 | 2009.76 | 31 | 14.79 | 2934 | 1345 | 1.57 / 602.26 | 2 | 2 |
3 | 13 | 1739.16 | 18 | 14.77 | 2615 | 695 | 2.26 / 602.96 | 2 | 3 |
4 | 13 | 1283.68 | 18 | 14.80 | 2031 | 541 | 2.80 / 603.50 | 2 | 3 |
5 | 13 | 550.44 | 18 | 14.94 | 1054 | 283 | 3.09 / 603.78 | 2 | 3 |
6 | 13 | 50.84 | 18 | 15.05 | 377 | 102 | 3.19 / 603.88 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.02 | 300 | 743 | 3.93 / 604.63 | 2 | 5 |
8 | 14 | 0.08 | 35 | 14.99 | 299 | 157 | 4.09 / 604.78 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 33 | 14.98 | 461 | 228 | 0.23 / 597.14 | 2 | 3 |
2 | 7 | 2005.32 | 31 | 14.78 | 2929 | 1342 | 1.57 / 598.48 | 2 | 2 |
3 | 13 | 1618.04 | 18 | 14.77 | 2456 | 653 | 2.22 / 599.13 | 2 | 3 |
4 | 13 | 1202.12 | 18 | 14.79 | 1926 | 513 | 2.74 / 599.65 | 2 | 3 |
5 | 13 | 614.28 | 18 | 14.90 | 1150 | 308 | 3.04 / 599.96 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.01 | 298 | 738 | 3.78 / 600.69 | 2 | 10 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 33 | 14.97 | 463 | 229 | 0.23 / 593.20 | 2 | 2 |
2 | 7 | 2007.60 | 31 | 14.77 | 2931 | 1342 | 1.57 / 594.55 | 2 | 3 |
3 | 13 | 1603.96 | 18 | 14.78 | 2435 | 648 | 2.22 / 595.19 | 2 | 3 |
4 | 13 | 1183.88 | 18 | 14.80 | 1900 | 506 | 2.72 / 595.70 | 2 | 3 |
5 | 13 | 599.56 | 18 | 14.91 | 1132 | 304 | 3.03 / 596.00 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.03 | 303 | 751 | 3.78 / 596.75 | 2 | 5 |
7 | 14 | 0.12 | 35 | 15.00 | 298 | 156 | 3.94 / 596.91 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 33 | 14.96 | 475 | 234 | 0.23 / 589.38 | 2 | 2 |
2 | 7 | 2003.00 | 31 | 14.78 | 2918 | 1337 | 1.57 / 590.72 | 2 | 3 |
3 | 13 | 1752.76 | 18 | 14.76 | 2622 | 697 | 2.27 / 591.41 | 2 | 3 |
4 | 13 | 1172.24 | 18 | 14.80 | 1892 | 504 | 2.77 / 591.92 | 2 | 3 |
5 | 13 | 599.84 | 18 | 14.91 | 1137 | 305 | 3.08 / 592.22 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.02 | 303 | 751 | 3.83 / 592.97 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 33 | 14.97 | 471 | 233 | 0.23 / 585.57 | 2 | 2 |
2 | 7 | 2012.16 | 31 | 14.78 | 2922 | 1339 | 1.57 / 586.91 | 2 | 2 |
3 | 13 | 1620.60 | 18 | 14.77 | 2465 | 655 | 2.23 / 587.57 | 2 | 3 |
4 | 13 | 1192.92 | 18 | 14.79 | 1913 | 509 | 2.74 / 588.08 | 2 | 3 |
5 | 13 | 611.84 | 18 | 14.91 | 1146 | 308 | 3.04 / 588.38 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.02 | 308 | 763 | 3.81 / 589.15 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 33 | 14.97 | 458 | 226 | 0.23 / 581.55 | 2 | 2 |
2 | 7 | 2006.72 | 31 | 14.79 | 2925 | 1341 | 1.57 / 582.89 | 2 | 2 |
3 | 13 | 1737.08 | 18 | 14.76 | 2623 | 697 | 2.26 / 583.59 | 2 | 3 |
4 | 13 | 1298.80 | 18 | 14.79 | 2058 | 548 | 2.81 / 584.13 | 2 | 3 |
5 | 13 | 710.16 | 18 | 14.89 | 1277 | 342 | 3.15 / 584.48 | 2 | 3 |
6 | 13 | 50.72 | 18 | 15.03 | 387 | 105 | 3.26 / 584.58 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.01 | 306 | 758 | 4.02 / 585.34 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 34 | 14.95 | 457 | 232 | 0.23 / 577.73 | 2 | 2 |
2 | 7 | 2004.92 | 31 | 14.78 | 2932 | 1343 | 1.58 / 579.07 | 2 | 3 |
3 | 13 | 1738.16 | 18 | 14.76 | 2619 | 696 | 2.27 / 579.77 | 2 | 3 |
4 | 13 | 1180.76 | 18 | 14.79 | 1914 | 510 | 2.78 / 580.28 | 2 | 3 |
5 | 13 | 591.48 | 18 | 14.90 | 1127 | 302 | 3.08 / 580.58 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.01 | 301 | 745 | 3.83 / 581.32 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 34 | 14.96 | 461 | 234 | 0.23 / 573.90 | 2 | 2 |
2 | 7 | 2006.04 | 32 | 14.78 | 2917 | 1380 | 1.61 / 575.28 | 2 | 2 |
3 | 13 | 1734.72 | 18 | 14.75 | 2606 | 692 | 2.31 / 575.97 | 2 | 3 |
4 | 13 | 1162.08 | 18 | 14.80 | 1866 | 497 | 2.80 / 576.47 | 2 | 3 |
5 | 13 | 582.32 | 18 | 14.90 | 1089 | 292 | 3.10 / 576.76 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.00 | 297 | 735 | 3.83 / 577.49 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 34 | 14.97 | 454 | 231 | 0.23 / 570.00 | 2 | 2 |
2 | 7 | 2004.08 | 31 | 14.82 | 2935 | 1348 | 1.58 / 571.35 | 2 | 2 |
3 | 13 | 1620.28 | 18 | 14.78 | 2464 | 656 | 2.23 / 572.01 | 2 | 3 |
4 | 13 | 1204.44 | 18 | 14.80 | 1932 | 515 | 2.75 / 572.52 | 2 | 3 |
5 | 13 | 634.00 | 18 | 14.89 | 1168 | 313 | 3.06 / 572.84 | 2 | 3 |
6 | 13 | 16.24 | 18 | 15.04 | 333 | 90 | 3.15 / 572.93 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.00 | 298 | 738 | 3.89 / 573.66 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 34 | 14.96 | 443 | 225 | 0.23 / 566.19 | 2 | 2 |
2 | 7 | 2009.28 | 31 | 14.78 | 2933 | 1344 | 1.57 / 567.53 | 2 | 2 |
3 | 13 | 1737.64 | 18 | 14.76 | 2603 | 692 | 2.26 / 568.23 | 2 | 3 |
4 | 13 | 1178.68 | 18 | 14.80 | 1904 | 507 | 2.77 / 568.73 | 2 | 3 |
5 | 13 | 603.04 | 18 | 14.91 | 1127 | 302 | 3.07 / 569.04 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.01 | 298 | 738 | 3.81 / 569.77 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 34 | 14.97 | 436 | 222 | 0.22 / 562.25 | 2 | 3 |
2 | 7 | 2005.52 | 31 | 14.81 | 2920 | 1341 | 1.56 / 563.59 | 2 | 2 |
3 | 13 | 1746.96 | 18 | 14.76 | 2625 | 697 | 2.26 / 564.28 | 2 | 3 |
4 | 13 | 1180.84 | 18 | 14.80 | 1902 | 507 | 2.77 / 564.79 | 2 | 3 |
5 | 13 | 747.04 | 18 | 14.86 | 1329 | 355 | 3.12 / 565.15 | 2 | 3 |
6 | 13 | 12.08 | 18 | 15.03 | 322 | 87 | 3.21 / 565.23 | 2 | 3 |
7 | 8 | 0.08 | 165 | 14.99 | 296 | 732 | 3.94 / 565.96 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 34 | 14.97 | 458 | 233 | 0.23 / 558.52 | 2 | 3 |
2 | 7 | 2013.24 | 31 | 14.79 | 2927 | 1342 | 1.58 / 559.87 | 2 | 2 |
3 | 13 | 1621.32 | 18 | 14.77 | 2450 | 651 | 2.23 / 560.52 | 2 | 3 |
4 | 13 | 1212.12 | 18 | 14.80 | 1925 | 513 | 2.74 / 561.03 | 2 | 3 |
5 | 13 | 504.60 | 18 | 14.93 | 986 | 265 | 3.00 / 561.30 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.00 | 294 | 728 | 3.73 / 562.02 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 34 | 14.97 | 445 | 226 | 0.23 / 554.68 | 2 | 2 |
2 | 7 | 2006.68 | 32 | 14.80 | 2928 | 1387 | 1.61 / 556.07 | 2 | 3 |
3 | 13 | 1743.72 | 18 | 14.76 | 2618 | 696 | 2.31 / 556.76 | 2 | 3 |
4 | 13 | 1175.68 | 18 | 14.80 | 1887 | 503 | 2.81 / 557.27 | 2 | 3 |
5 | 13 | 597.88 | 18 | 14.90 | 1108 | 297 | 3.11 / 557.56 | 2 | 3 |
6 | 8 | 0.16 | 165 | 14.99 | 294 | 727 | 3.84 / 558.29 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 34 | 14.96 | 454 | 231 | 0.23 / 550.96 | 2 | 3 |
2 | 7 | 2006.08 | 31 | 14.81 | 2911 | 1336 | 1.57 / 552.30 | 2 | 3 |
3 | 13 | 1619.96 | 18 | 14.79 | 2444 | 651 | 2.22 / 552.95 | 2 | 3 |
4 | 13 | 1202.60 | 18 | 14.81 | 1922 | 512 | 2.73 / 553.46 | 2 | 3 |
5 | 13 | 501.36 | 18 | 14.93 | 984 | 264 | 2.99 / 553.72 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.02 | 295 | 731 | 3.73 / 554.46 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 34 | 14.96 | 453 | 230 | 0.23 / 547.07 | 2 | 2 |
2 | 7 | 2006.68 | 31 | 14.80 | 2928 | 1343 | 1.57 / 548.42 | 2 | 3 |
3 | 13 | 1731.88 | 18 | 14.77 | 2611 | 694 | 2.27 / 549.11 | 2 | 3 |
4 | 13 | 1165.12 | 18 | 14.82 | 1871 | 499 | 2.77 / 549.61 | 2 | 3 |
5 | 13 | 597.92 | 18 | 14.92 | 1116 | 300 | 3.07 / 549.91 | 2 | 3 |
6 | 13 | 59.24 | 18 | 15.03 | 380 | 103 | 3.17 / 550.01 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.00 | 290 | 718 | 3.89 / 550.73 | 2 | 9 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 34 | 14.97 | 453 | 231 | 0.23 / 543.14 | 2 | 2 |
2 | 7 | 2010.56 | 31 | 14.80 | 2922 | 1341 | 1.57 / 544.48 | 2 | 2 |
3 | 13 | 1742.92 | 18 | 14.77 | 2610 | 694 | 2.27 / 545.17 | 2 | 3 |
4 | 13 | 1169.84 | 18 | 14.82 | 1874 | 500 | 2.76 / 545.67 | 2 | 3 |
5 | 13 | 591.88 | 18 | 14.91 | 1105 | 297 | 3.06 / 545.97 | 2 | 3 |
6 | 8 | 0.68 | 165 | 15.02 | 291 | 721 | 3.78 / 546.69 | 2 | 6 |
7 | 14 | 0.68 | 35 | 15.00 | 292 | 153 | 3.94 / 546.84 | 2 | 8 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 34 | 14.95 | 457 | 232 | 0.23 / 539.22 | 2 | 3 |
2 | 7 | 2008.32 | 31 | 14.79 | 2919 | 1338 | 1.57 / 540.55 | 2 | 3 |
3 | 13 | 1729.60 | 18 | 14.77 | 2586 | 688 | 2.26 / 541.24 | 2 | 3 |
4 | 13 | 1152.28 | 18 | 14.81 | 1857 | 495 | 2.75 / 541.74 | 2 | 3 |
5 | 13 | 573.44 | 18 | 14.91 | 1093 | 293 | 3.05 / 542.03 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.01 | 292 | 723 | 3.77 / 542.75 | 2 | 5 |
7 | 14 | 0.20 | 35 | 14.98 | 292 | 153 | 3.92 / 542.91 | 3 | 8 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 34 | 14.96 | 443 | 225 | 0.23 / 535.33 | 2 | 3 |
2 | 7 | 2004.52 | 31 | 14.80 | 2904 | 1332 | 1.56 / 536.66 | 2 | 2 |
3 | 13 | 1732.52 | 18 | 14.77 | 2590 | 689 | 2.25 / 537.35 | 2 | 3 |
4 | 13 | 1166.20 | 18 | 14.81 | 1879 | 501 | 2.75 / 537.85 | 2 | 3 |
5 | 13 | 588.64 | 18 | 14.90 | 1110 | 298 | 3.04 / 538.15 | 2 | 3 |
6 | 13 | 58.64 | 18 | 15.01 | 383 | 103 | 3.15 / 538.25 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.00 | 295 | 730 | 3.88 / 538.98 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 34 | 14.96 | 436 | 222 | 0.22 / 531.57 | 2 | 3 |
2 | 7 | 2005.32 | 31 | 14.80 | 2917 | 1338 | 1.56 / 532.91 | 2 | 3 |
3 | 13 | 1620.52 | 18 | 14.77 | 2456 | 653 | 2.21 / 533.57 | 2 | 3 |
4 | 13 | 1200.52 | 18 | 14.80 | 1912 | 509 | 2.72 / 534.07 | 2 | 3 |
5 | 13 | 616.36 | 18 | 14.91 | 1136 | 305 | 3.03 / 534.38 | 2 | 3 |
6 | 8 | 0.44 | 165 | 15.01 | 293 | 726 | 3.75 / 535.11 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 34 | 14.95 | 451 | 229 | 0.23 / 527.87 | 2 | 3 |
2 | 7 | 2013.92 | 31 | 14.80 | 2935 | 1347 | 1.58 / 529.21 | 2 | 2 |
3 | 13 | 1624.72 | 18 | 14.79 | 2473 | 658 | 2.23 / 529.87 | 2 | 3 |
4 | 13 | 1105.76 | 18 | 14.82 | 1799 | 480 | 2.71 / 530.35 | 2 | 3 |
5 | 13 | 541.68 | 18 | 14.92 | 1042 | 280 | 2.99 / 530.63 | 2 | 3 |
6 | 8 | -0.28 | 165 | 15.00 | 291 | 720 | 3.71 / 531.35 | 2 | 3 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 34 | 14.94 | 452 | 230 | 0.23 / 523.97 | 2 | 3 |
2 | 7 | 2008.52 | 31 | 14.80 | 2918 | 1339 | 1.57 / 525.31 | 2 | 2 |
3 | 13 | 1739.56 | 18 | 14.77 | 2607 | 693 | 2.26 / 526.00 | 2 | 2 |
4 | 13 | 1177.16 | 18 | 14.82 | 1881 | 502 | 2.76 / 526.51 | 2 | 3 |
5 | 13 | 594.40 | 18 | 14.93 | 1115 | 300 | 3.06 / 526.81 | 2 | 3 |
6 | 13 | 64.44 | 18 | 15.02 | 395 | 107 | 3.17 / 526.91 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.00 | 293 | 725 | 3.89 / 527.64 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 34 | 14.97 | 449 | 229 | 0.23 / 520.10 | 2 | 3 |
2 | 7 | 2004.36 | 31 | 14.79 | 2916 | 1337 | 1.57 / 521.43 | 2 | 3 |
3 | 13 | 1612.48 | 18 | 14.79 | 2463 | 656 | 2.22 / 522.09 | 2 | 3 |
4 | 13 | 1214.88 | 18 | 14.81 | 1928 | 514 | 2.74 / 522.60 | 2 | 3 |
5 | 13 | 633.48 | 18 | 14.92 | 1164 | 313 | 3.05 / 522.91 | 2 | 3 |
6 | 13 | 41.84 | 18 | 15.03 | 356 | 96 | 3.14 / 523.01 | 2 | 2 |
7 | 8 | 0.36 | 165 | 15.00 | 296 | 733 | 3.88 / 523.74 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 34 | 14.97 | 455 | 232 | 0.23 / 516.20 | 2 | 3 |
2 | 7 | 2010.92 | 31 | 14.82 | 2925 | 1344 | 1.58 / 517.54 | 2 | 3 |
3 | 13 | 1738.04 | 18 | 14.78 | 2605 | 693 | 2.27 / 518.24 | 2 | 3 |
4 | 13 | 1167.48 | 18 | 14.82 | 1880 | 502 | 2.77 / 518.74 | 2 | 3 |
5 | 13 | 588.36 | 18 | 14.92 | 1103 | 296 | 3.07 / 519.03 | 2 | 3 |
6 | 13 | 58.12 | 18 | 15.03 | 383 | 104 | 3.17 / 519.14 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.01 | 294 | 728 | 3.90 / 519.87 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 33 | 14.97 | 457 | 226 | 0.23 / 512.31 | 2 | 3 |
2 | 7 | 2007.24 | 31 | 14.80 | 2906 | 1333 | 1.56 / 513.64 | 2 | 2 |
3 | 13 | 1739.88 | 18 | 14.77 | 2607 | 693 | 2.25 / 514.33 | 2 | 3 |
4 | 13 | 1177.00 | 18 | 14.82 | 1883 | 502 | 2.75 / 514.84 | 2 | 3 |
5 | 13 | 603.96 | 18 | 14.92 | 1121 | 301 | 3.06 / 515.14 | 2 | 3 |
6 | 13 | 35.28 | 18 | 15.05 | 363 | 98 | 3.15 / 515.24 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.01 | 296 | 733 | 3.89 / 515.97 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 33 | 14.98 | 462 | 228 | 0.23 / 508.33 | 2 | 3 |
2 | 7 | 2003.08 | 31 | 14.82 | 2916 | 1340 | 1.57 / 509.67 | 2 | 2 |
3 | 13 | 1746.68 | 18 | 14.77 | 2621 | 697 | 2.26 / 510.37 | 2 | 3 |
4 | 13 | 1297.04 | 18 | 14.80 | 2056 | 548 | 2.81 / 510.92 | 2 | 3 |
5 | 13 | 692.84 | 18 | 14.90 | 1244 | 334 | 3.15 / 511.25 | 2 | 3 |
6 | 13 | 43.72 | 18 | 15.05 | 367 | 99 | 3.25 / 511.35 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.02 | 296 | 734 | 3.98 / 512.08 | 2 | 10 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 33 | 15.00 | 457 | 226 | 0.23 / 504.30 | 2 | 3 |
2 | 7 | 2006.68 | 31 | 14.82 | 2925 | 1344 | 1.57 / 505.65 | 2 | 2 |
3 | 13 | 1752.92 | 18 | 14.78 | 2621 | 697 | 2.27 / 506.34 | 2 | 3 |
4 | 13 | 1302.92 | 18 | 14.81 | 2048 | 546 | 2.81 / 506.89 | 2 | 3 |
5 | 13 | 706.40 | 18 | 14.90 | 1271 | 341 | 3.15 / 507.23 | 2 | 3 |
6 | 13 | 48.04 | 18 | 15.05 | 396 | 107 | 3.26 / 507.34 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.02 | 309 | 766 | 4.03 / 508.10 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 33 | 14.98 | 437 | 216 | 0.22 / 500.47 | 2 | 3 |
2 | 7 | 2008.60 | 31 | 14.80 | 2937 | 1347 | 1.56 / 501.82 | 2 | 2 |
3 | 13 | 1741.08 | 18 | 14.78 | 2620 | 697 | 2.26 / 502.51 | 2 | 3 |
4 | 13 | 1292.84 | 18 | 14.81 | 2042 | 544 | 2.80 / 503.06 | 2 | 3 |
5 | 13 | 573.68 | 18 | 14.94 | 1086 | 292 | 3.10 / 503.35 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.03 | 293 | 727 | 3.82 / 504.08 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 33 | 14.96 | 465 | 230 | 0.23 / 496.63 | 2 | 3 |
2 | 7 | 2007.56 | 31 | 14.81 | 2925 | 1343 | 1.57 / 497.97 | 2 | 3 |
3 | 13 | 1595.36 | 18 | 14.80 | 2427 | 647 | 2.22 / 498.62 | 2 | 3 |
4 | 13 | 1170.60 | 18 | 14.82 | 1896 | 506 | 2.72 / 499.13 | 2 | 3 |
5 | 13 | 596.00 | 18 | 14.92 | 1122 | 301 | 3.03 / 499.43 | 2 | 3 |
6 | 13 | 24.56 | 18 | 15.06 | 337 | 91 | 3.12 / 499.52 | 2 | 3 |
7 | 8 | -0.12 | 165 | 15.01 | 296 | 733 | 3.85 / 500.25 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 33 | 14.98 | 460 | 227 | 0.23 / 492.79 | 2 | 3 |
2 | 7 | 2004.96 | 31 | 14.81 | 2926 | 1343 | 1.57 / 494.13 | 2 | 3 |
3 | 13 | 1611.68 | 18 | 14.79 | 2443 | 650 | 2.22 / 494.78 | 2 | 3 |
4 | 13 | 1081.36 | 18 | 14.83 | 1767 | 472 | 2.69 / 495.25 | 2 | 3 |
5 | 13 | 530.60 | 18 | 14.94 | 1043 | 280 | 2.97 / 495.53 | 2 | 3 |
6 | 13 | 38.80 | 18 | 15.05 | 373 | 101 | 3.07 / 495.63 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.01 | 310 | 768 | 3.84 / 496.40 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 33 | 14.97 | 468 | 231 | 0.23 / 488.98 | 2 | 2 |
2 | 7 | 2005.68 | 32 | 14.81 | 2940 | 1393 | 1.62 / 490.38 | 2 | 3 |
3 | 13 | 1617.36 | 18 | 14.79 | 2489 | 663 | 2.29 / 491.04 | 2 | 3 |
4 | 13 | 1193.92 | 18 | 14.83 | 1927 | 514 | 2.80 / 491.55 | 2 | 3 |
5 | 13 | 489.64 | 18 | 14.96 | 973 | 262 | 3.06 / 491.82 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.03 | 300 | 744 | 3.81 / 492.56 | 2 | 3 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 33 | 14.99 | 461 | 228 | 0.23 / 485.12 | 2 | 2 |
2 | 7 | 2008.12 | 31 | 14.81 | 2920 | 1341 | 1.57 / 486.46 | 2 | 2 |
3 | 13 | 1613.68 | 18 | 14.80 | 2458 | 655 | 2.22 / 487.12 | 2 | 2 |
4 | 13 | 1177.88 | 18 | 14.84 | 1893 | 506 | 2.73 / 487.62 | 2 | 3 |
5 | 13 | 596.80 | 18 | 14.93 | 1116 | 300 | 3.03 / 487.92 | 2 | 3 |
6 | 13 | 23.68 | 18 | 15.06 | 339 | 92 | 3.12 / 488.01 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.02 | 298 | 739 | 3.86 / 488.75 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 33 | 14.98 | 459 | 227 | 0.23 / 481.31 | 2 | 3 |
2 | 7 | 2010.80 | 32 | 14.81 | 2924 | 1386 | 1.61 / 482.69 | 2 | 3 |
3 | 13 | 1743.96 | 18 | 14.78 | 2613 | 695 | 2.31 / 483.39 | 2 | 2 |
4 | 13 | 1159.04 | 18 | 14.84 | 1879 | 502 | 2.81 / 483.89 | 2 | 3 |
5 | 13 | 471.36 | 18 | 14.98 | 952 | 257 | 3.07 / 484.15 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.03 | 301 | 746 | 3.81 / 484.89 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 33 | 14.99 | 446 | 221 | 0.22 / 477.40 | 2 | 3 |
2 | 7 | 2004.00 | 31 | 14.80 | 2913 | 1336 | 1.56 / 478.74 | 2 | 3 |
3 | 13 | 1743.72 | 18 | 14.77 | 2615 | 695 | 2.25 / 479.43 | 2 | 3 |
4 | 13 | 1170.92 | 18 | 14.81 | 1882 | 502 | 2.75 / 479.93 | 2 | 3 |
5 | 13 | 474.92 | 18 | 14.96 | 951 | 256 | 3.01 / 480.19 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.02 | 297 | 736 | 3.75 / 480.92 | 2 | 3 |
7 | 14 | 0.04 | 35 | 15.00 | 294 | 154 | 3.90 / 481.08 | 2 | 8 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 33 | 14.97 | 467 | 231 | 0.23 / 473.67 | 2 | 3 |
2 | 7 | 2010.12 | 31 | 14.80 | 2929 | 1344 | 1.57 / 475.02 | 2 | 3 |
3 | 13 | 1612.24 | 18 | 14.79 | 2458 | 654 | 2.23 / 475.67 | 2 | 3 |
4 | 13 | 1191.56 | 18 | 14.81 | 1913 | 510 | 2.74 / 476.18 | 2 | 3 |
5 | 13 | 475.32 | 18 | 14.96 | 952 | 256 | 3.00 / 476.44 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.02 | 299 | 741 | 3.74 / 477.18 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 33 | 14.97 | 459 | 227 | 0.23 / 469.80 | 2 | 2 |
2 | 7 | 2011.04 | 31 | 14.82 | 2926 | 1344 | 1.57 / 471.15 | 2 | 2 |
3 | 13 | 1756.00 | 18 | 14.77 | 2638 | 701 | 2.27 / 471.85 | 2 | 3 |
4 | 13 | 1301.40 | 18 | 14.80 | 2047 | 545 | 2.82 / 472.40 | 2 | 3 |
5 | 13 | 576.36 | 18 | 14.93 | 1090 | 293 | 3.11 / 472.69 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.03 | 304 | 754 | 3.86 / 473.44 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 33 | 14.99 | 455 | 225 | 0.23 / 466.09 | 2 | 3 |
2 | 7 | 2007.32 | 31 | 14.81 | 2915 | 1338 | 1.56 / 467.42 | 2 | 3 |
3 | 13 | 1605.40 | 18 | 14.79 | 2435 | 648 | 2.21 / 468.07 | 2 | 3 |
4 | 13 | 1180.64 | 18 | 14.82 | 1898 | 506 | 2.72 / 468.58 | 2 | 3 |
5 | 13 | 466.76 | 18 | 14.95 | 941 | 253 | 2.97 / 468.83 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.02 | 301 | 746 | 3.72 / 469.58 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 33 | 15.00 | 460 | 228 | 0.23 / 462.31 | 2 | 3 |
2 | 7 | 2005.16 | 31 | 14.81 | 2927 | 1344 | 1.57 / 463.65 | 2 | 3 |
3 | 13 | 1616.08 | 18 | 14.80 | 2454 | 654 | 2.23 / 464.30 | 2 | 3 |
4 | 13 | 1193.64 | 18 | 14.82 | 1926 | 514 | 2.74 / 464.82 | 2 | 3 |
5 | 13 | 604.80 | 18 | 14.92 | 1126 | 302 | 3.04 / 465.12 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.03 | 299 | 742 | 3.78 / 465.86 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 33 | 14.98 | 461 | 228 | 0.23 / 458.57 | 2 | 3 |
2 | 7 | 2005.04 | 31 | 14.81 | 2919 | 1340 | 1.57 / 459.91 | 2 | 3 |
3 | 13 | 1601.72 | 18 | 14.80 | 2449 | 652 | 2.22 / 460.56 | 2 | 3 |
4 | 13 | 1184.44 | 18 | 14.82 | 1907 | 509 | 2.73 / 461.07 | 2 | 3 |
5 | 13 | 476.16 | 18 | 14.96 | 963 | 259 | 2.99 / 461.33 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.03 | 303 | 751 | 3.74 / 462.08 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 33 | 14.99 | 461 | 228 | 0.23 / 454.56 | 2 | 2 |
2 | 7 | 2010.80 | 31 | 14.80 | 2915 | 1337 | 1.57 / 455.90 | 2 | 3 |
3 | 13 | 1618.36 | 18 | 14.80 | 2458 | 655 | 2.22 / 456.55 | 2 | 3 |
4 | 13 | 1193.28 | 18 | 14.83 | 1902 | 508 | 2.73 / 457.06 | 2 | 3 |
5 | 13 | 487.08 | 18 | 14.95 | 978 | 263 | 2.99 / 457.33 | 2 | 3 |
6 | 13 | 17.24 | 18 | 15.06 | 336 | 91 | 3.08 / 457.42 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.03 | 307 | 761 | 3.84 / 458.18 | 2 | 4 |
8 | 14 | -0.08 | 35 | 15.00 | 305 | 160 | 4.00 / 458.34 | 2 | 9 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 33 | 14.99 | 465 | 230 | 0.23 / 450.78 | 2 | 3 |
2 | 7 | 2005.80 | 31 | 14.79 | 2923 | 1340 | 1.57 / 452.12 | 2 | 2 |
3 | 13 | 1606.40 | 18 | 14.80 | 2450 | 653 | 2.22 / 452.78 | 2 | 3 |
4 | 13 | 1181.04 | 18 | 14.82 | 1891 | 504 | 2.73 / 453.28 | 2 | 3 |
5 | 13 | 602.24 | 18 | 14.94 | 1132 | 304 | 3.03 / 453.58 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.04 | 302 | 749 | 3.78 / 454.33 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 33 | 14.99 | 452 | 224 | 0.22 / 447.01 | 2 | 3 |
2 | 7 | 2004.28 | 31 | 14.80 | 2927 | 1343 | 1.57 / 448.35 | 2 | 3 |
3 | 13 | 1733.04 | 18 | 14.77 | 2608 | 693 | 2.26 / 449.05 | 2 | 3 |
4 | 13 | 1153.28 | 18 | 14.84 | 1861 | 497 | 2.76 / 449.55 | 2 | 3 |
5 | 13 | 472.24 | 18 | 14.96 | 960 | 259 | 3.02 / 449.80 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.04 | 302 | 749 | 3.76 / 450.55 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 33 | 15.00 | 472 | 234 | 0.23 / 443.03 | 2 | 2 |
2 | 7 | 2010.56 | 31 | 14.81 | 2945 | 1352 | 1.59 / 444.39 | 2 | 3 |
3 | 13 | 1733.92 | 18 | 14.79 | 2602 | 693 | 2.28 / 445.08 | 2 | 3 |
4 | 13 | 1147.44 | 18 | 14.83 | 1857 | 496 | 2.77 / 445.57 | 2 | 3 |
5 | 13 | 589.32 | 18 | 14.94 | 1120 | 301 | 3.08 / 445.88 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.03 | 303 | 751 | 3.83 / 446.63 | 2 | 6 |
7 | 14 | 0.08 | 35 | 15.02 | 306 | 161 | 3.99 / 446.79 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.84 | 33 | 14.98 | 473 | 234 | 0.23 / 439.22 | 2 | 2 |
2 | 7 | 2006.00 | 31 | 14.80 | 2916 | 1338 | 1.57 / 440.56 | 2 | 2 |
3 | 13 | 1619.40 | 18 | 14.79 | 2460 | 655 | 2.23 / 441.21 | 2 | 3 |
4 | 13 | 1216.44 | 18 | 14.81 | 1947 | 519 | 2.75 / 441.73 | 2 | 3 |
5 | 13 | 625.84 | 18 | 14.93 | 1163 | 313 | 3.06 / 442.05 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.04 | 304 | 754 | 3.81 / 442.80 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 33 | 14.99 | 454 | 225 | 0.22 / 435.28 | 2 | 2 |
2 | 7 | 2004.44 | 32 | 14.81 | 2916 | 1382 | 1.61 / 436.66 | 2 | 3 |
3 | 13 | 1617.00 | 18 | 14.79 | 2446 | 651 | 2.26 / 437.31 | 2 | 3 |
4 | 13 | 1184.48 | 18 | 14.81 | 1916 | 511 | 2.77 / 437.82 | 2 | 3 |
5 | 13 | 473.28 | 18 | 14.97 | 959 | 258 | 3.03 / 438.08 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.03 | 301 | 746 | 3.77 / 438.83 | 2 | 6 |
7 | 14 | 0.04 | 35 | 15.02 | 302 | 159 | 3.93 / 438.99 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 33 | 14.99 | 464 | 230 | 0.23 / 431.37 | 2 | 2 |
2 | 7 | 2007.92 | 31 | 14.82 | 2927 | 1345 | 1.57 / 432.72 | 2 | 3 |
3 | 13 | 1736.36 | 18 | 14.80 | 2604 | 694 | 2.27 / 433.41 | 2 | 3 |
4 | 13 | 1171.68 | 18 | 14.83 | 1888 | 504 | 2.77 / 433.91 | 2 | 3 |
5 | 13 | 607.00 | 18 | 14.93 | 1134 | 305 | 3.08 / 434.22 | 2 | 3 |
6 | 13 | 16.24 | 18 | 15.07 | 330 | 90 | 3.17 / 434.31 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.03 | 302 | 749 | 3.92 / 435.06 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 33 | 14.98 | 454 | 224 | 0.22 / 427.49 | 2 | 3 |
2 | 7 | 2011.24 | 31 | 14.82 | 2927 | 1345 | 1.57 / 428.83 | 2 | 3 |
3 | 13 | 1746.76 | 18 | 14.78 | 2617 | 696 | 2.27 / 429.53 | 2 | 3 |
4 | 13 | 1301.08 | 18 | 14.81 | 2063 | 550 | 2.82 / 430.08 | 2 | 3 |
5 | 13 | 563.68 | 18 | 14.94 | 1079 | 290 | 3.11 / 430.37 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.04 | 311 | 772 | 3.88 / 431.14 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 33 | 14.97 | 458 | 226 | 0.23 / 423.52 | 2 | 2 |
2 | 7 | 2005.60 | 31 | 14.81 | 2913 | 1337 | 1.56 / 424.86 | 2 | 2 |
3 | 13 | 1739.12 | 18 | 14.80 | 2611 | 696 | 2.26 / 425.55 | 2 | 3 |
4 | 13 | 1156.72 | 18 | 14.85 | 1879 | 502 | 2.76 / 426.05 | 2 | 3 |
5 | 13 | 581.32 | 18 | 14.96 | 1113 | 300 | 3.06 / 426.35 | 2 | 3 |
6 | 8 | 0.56 | 165 | 15.05 | 302 | 750 | 3.81 / 427.10 | 2 | 4 |
7 | 14 | 0.56 | 35 | 15.03 | 303 | 159 | 3.97 / 427.26 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 33 | 14.98 | 476 | 235 | 0.24 / 419.43 | 2 | 2 |
2 | 7 | 2010.56 | 31 | 14.82 | 2931 | 1347 | 1.58 / 420.77 | 2 | 2 |
3 | 13 | 1743.96 | 18 | 14.79 | 2626 | 699 | 2.28 / 421.47 | 2 | 3 |
4 | 13 | 1166.16 | 18 | 14.84 | 1882 | 503 | 2.78 / 421.97 | 2 | 3 |
5 | 13 | 604.52 | 18 | 14.94 | 1131 | 304 | 3.09 / 422.28 | 2 | 4 |
6 | 13 | 31.48 | 18 | 15.07 | 357 | 97 | 3.18 / 422.38 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.04 | 305 | 757 | 3.94 / 423.13 | 2 | 4 |
8 | 14 | -0.04 | 35 | 15.01 | 306 | 161 | 4.10 / 423.29 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 33 | 14.98 | 459 | 227 | 0.23 / 415.51 | 2 | 2 |
2 | 7 | 2008.52 | 31 | 14.81 | 2939 | 1349 | 1.58 / 416.85 | 2 | 3 |
3 | 13 | 1619.76 | 18 | 14.80 | 2459 | 655 | 2.23 / 417.51 | 2 | 3 |
4 | 13 | 1194.16 | 18 | 14.82 | 1934 | 516 | 2.75 / 418.03 | 2 | 3 |
5 | 13 | 614.12 | 18 | 14.93 | 1156 | 311 | 3.06 / 418.34 | 2 | 3 |
6 | 13 | 16.16 | 18 | 15.08 | 340 | 92 | 3.15 / 418.43 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.04 | 307 | 762 | 3.91 / 419.19 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 33 | 14.98 | 472 | 233 | 0.23 / 411.58 | 2 | 2 |
2 | 7 | 2003.48 | 32 | 14.80 | 2918 | 1382 | 1.62 / 412.96 | 2 | 3 |
3 | 13 | 1608.40 | 18 | 14.80 | 2454 | 654 | 2.27 / 413.61 | 2 | 3 |
4 | 13 | 1204.44 | 18 | 14.82 | 1938 | 517 | 2.79 / 414.13 | 2 | 3 |
5 | 13 | 613.16 | 18 | 14.93 | 1151 | 309 | 3.10 / 414.44 | 2 | 3 |
6 | 13 | 26.40 | 18 | 15.07 | 348 | 94 | 3.19 / 414.53 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.04 | 301 | 747 | 3.94 / 415.28 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 33 | 14.98 | 459 | 227 | 0.23 / 407.61 | 2 | 3 |
2 | 7 | 2006.12 | 31 | 14.81 | 2925 | 1343 | 1.57 / 408.95 | 2 | 3 |
3 | 13 | 1747.24 | 18 | 14.79 | 2619 | 697 | 2.27 / 409.65 | 2 | 3 |
4 | 13 | 1176.44 | 18 | 14.83 | 1892 | 505 | 2.77 / 410.15 | 2 | 3 |
5 | 13 | 601.00 | 18 | 14.95 | 1127 | 303 | 3.08 / 410.46 | 2 | 3 |
6 | 13 | 58.24 | 18 | 15.06 | 408 | 111 | 3.19 / 410.57 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.03 | 312 | 774 | 3.96 / 411.34 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 33 | 15.00 | 443 | 219 | 0.22 / 403.49 | 2 | 3 |
2 | 7 | 2011.12 | 31 | 14.82 | 2931 | 1347 | 1.57 / 404.84 | 2 | 3 |
3 | 13 | 1881.92 | 18 | 14.76 | 2794 | 742 | 2.31 / 405.58 | 2 | 2 |
4 | 13 | 1142.76 | 18 | 14.85 | 1840 | 492 | 2.80 / 406.08 | 2 | 3 |
5 | 13 | 570.68 | 18 | 14.95 | 1090 | 293 | 3.09 / 406.37 | 2 | 3 |
6 | 13 | 56.08 | 18 | 15.06 | 392 | 106 | 3.20 / 406.48 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.03 | 302 | 749 | 3.95 / 407.22 | 2 | 3 |
8 | 14 | 0.20 | 35 | 15.01 | 301 | 158 | 4.11 / 407.38 | 2 | 6 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 33 | 14.99 | 457 | 226 | 0.23 / 399.44 | 2 | 2 |
2 | 7 | 2005.60 | 31 | 14.81 | 2914 | 1338 | 1.56 / 400.78 | 2 | 2 |
3 | 13 | 1741.08 | 18 | 14.78 | 2611 | 695 | 2.26 / 401.47 | 2 | 3 |
4 | 13 | 1157.08 | 18 | 14.83 | 1863 | 497 | 2.76 / 401.97 | 2 | 3 |
5 | 13 | 574.72 | 18 | 14.94 | 1097 | 295 | 3.05 / 402.26 | 2 | 3 |
6 | 13 | 46.20 | 18 | 15.07 | 383 | 104 | 3.15 / 402.37 | 2 | 3 |
7 | 8 | -0.16 | 165 | 15.03 | 302 | 749 | 3.90 / 403.12 | 2 | 6 |
8 | 14 | -0.16 | 35 | 15.00 | 303 | 159 | 4.06 / 403.28 | 2 | 12 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 33 | 14.99 | 451 | 223 | 0.22 / 395.52 | 2 | 3 |
2 | 7 | 2011.24 | 31 | 14.82 | 2919 | 1341 | 1.56 / 396.86 | 2 | 2 |
3 | 13 | 1743.00 | 18 | 14.79 | 2613 | 696 | 2.26 / 397.56 | 2 | 2 |
4 | 13 | 1172.84 | 18 | 14.84 | 1891 | 505 | 2.76 / 398.06 | 2 | 3 |
5 | 13 | 608.56 | 18 | 14.93 | 1140 | 306 | 3.07 / 398.37 | 2 | 3 |
6 | 13 | 66.04 | 18 | 15.04 | 402 | 109 | 3.18 / 398.48 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.02 | 297 | 736 | 3.92 / 399.21 | 2 | 5 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 33 | 14.99 | 452 | 224 | 0.22 / 391.81 | 2 | 3 |
2 | 7 | 2006.48 | 31 | 14.81 | 2929 | 1345 | 1.57 / 393.16 | 2 | 3 |
3 | 13 | 1502.40 | 18 | 14.81 | 2318 | 618 | 2.19 / 393.77 | 2 | 3 |
4 | 13 | 1119.00 | 18 | 14.83 | 1815 | 484 | 2.67 / 394.26 | 2 | 3 |
5 | 13 | 556.24 | 18 | 14.95 | 1071 | 288 | 2.96 / 394.55 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.04 | 302 | 749 | 3.71 / 395.30 | 2 | 6 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 33 | 14.99 | 448 | 222 | 0.22 / 387.90 | 2 | 3 |
2 | 7 | 2005.00 | 31 | 14.82 | 2915 | 1339 | 1.56 / 389.24 | 2 | 3 |
3 | 13 | 1735.72 | 18 | 14.79 | 2609 | 695 | 2.26 / 389.93 | 2 | 3 |
4 | 13 | 1265.56 | 18 | 14.82 | 2006 | 535 | 2.79 / 390.47 | 2 | 3 |
5 | 13 | 519.92 | 18 | 14.97 | 1024 | 276 | 3.07 / 390.74 | 2 | 3 |
6 | 13 | 51.08 | 18 | 15.07 | 381 | 103 | 3.17 / 390.85 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.04 | 299 | 742 | 3.91 / 391.59 | 2 | 6 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 33 | 14.99 | 465 | 230 | 0.23 / 383.94 | 2 | 2 |
2 | 7 | 2006.60 | 31 | 14.83 | 2915 | 1340 | 1.57 / 385.28 | 2 | 2 |
3 | 13 | 1622.44 | 18 | 14.81 | 2453 | 654 | 2.22 / 385.94 | 2 | 3 |
4 | 13 | 1196.00 | 18 | 14.84 | 1913 | 511 | 2.74 / 386.45 | 2 | 3 |
5 | 13 | 752.04 | 18 | 14.90 | 1342 | 360 | 3.09 / 386.81 | 2 | 3 |
6 | 13 | 64.72 | 18 | 15.06 | 414 | 112 | 3.21 / 386.92 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.03 | 305 | 756 | 3.96 / 387.68 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 33 | 15.00 | 455 | 225 | 0.23 / 380.05 | 2 | 2 |
2 | 7 | 2006.44 | 31 | 14.82 | 2925 | 1344 | 1.57 / 381.40 | 2 | 2 |
3 | 13 | 1615.04 | 18 | 14.81 | 2451 | 653 | 2.22 / 382.05 | 2 | 3 |
4 | 13 | 1071.12 | 18 | 14.86 | 1768 | 473 | 2.70 / 382.52 | 2 | 3 |
5 | 13 | 638.96 | 18 | 14.92 | 1202 | 323 | 3.02 / 382.84 | 2 | 3 |
6 | 13 | 40.40 | 18 | 15.06 | 387 | 105 | 3.12 / 382.95 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.03 | 308 | 764 | 3.89 / 383.71 | 2 | 6 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 33 | 15.00 | 462 | 229 | 0.23 / 376.08 | 2 | 3 |
2 | 7 | 2008.08 | 31 | 14.83 | 2924 | 1344 | 1.57 / 377.42 | 2 | 3 |
3 | 13 | 1735.60 | 18 | 14.79 | 2606 | 694 | 2.27 / 378.11 | 2 | 2 |
4 | 13 | 1163.60 | 18 | 14.85 | 1877 | 502 | 2.77 / 378.62 | 2 | 3 |
5 | 13 | 735.00 | 18 | 14.91 | 1315 | 353 | 3.12 / 378.97 | 2 | 3 |
6 | 13 | 53.76 | 18 | 15.08 | 395 | 107 | 3.23 / 379.08 | 2 | 3 |
7 | 8 | -0.12 | 165 | 15.05 | 302 | 750 | 3.98 / 379.83 | 2 | 6 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 33 | 15.00 | 450 | 223 | 0.22 / 372.16 | 2 | 2 |
2 | 7 | 2006.12 | 31 | 14.83 | 2922 | 1343 | 1.57 / 373.51 | 2 | 3 |
3 | 13 | 1738.68 | 18 | 14.80 | 2610 | 695 | 2.26 / 374.20 | 2 | 3 |
4 | 13 | 1151.28 | 18 | 14.85 | 1859 | 497 | 2.76 / 374.70 | 2 | 3 |
5 | 13 | 573.20 | 18 | 14.95 | 1095 | 295 | 3.05 / 374.99 | 2 | 3 |
6 | 13 | 28.48 | 18 | 15.07 | 358 | 97 | 3.15 / 375.09 | 2 | 3 |
7 | 8 | 0.32 | 165 | 15.04 | 305 | 757 | 3.91 / 375.85 | 2 | 6 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 33 | 14.99 | 462 | 229 | 0.23 / 368.33 | 2 | 2 |
2 | 7 | 2007.76 | 31 | 14.84 | 2921 | 1344 | 1.57 / 369.67 | 2 | 3 |
3 | 13 | 1599.12 | 18 | 14.83 | 2439 | 651 | 2.22 / 370.32 | 2 | 3 |
4 | 13 | 1175.60 | 18 | 14.85 | 1897 | 507 | 2.73 / 370.83 | 2 | 3 |
5 | 13 | 484.80 | 18 | 14.99 | 975 | 263 | 2.99 / 371.09 | 2 | 3 |
6 | 13 | 34.64 | 18 | 15.08 | 366 | 99 | 3.09 / 371.19 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.04 | 301 | 747 | 3.84 / 371.94 | 2 | 7 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 33 | 14.98 | 481 | 238 | 0.24 / 364.43 | 2 | 3 |
2 | 7 | 2003.80 | 31 | 14.83 | 2918 | 1341 | 1.58 / 365.77 | 2 | 2 |
3 | 13 | 1614.52 | 18 | 14.82 | 2447 | 653 | 2.23 / 366.42 | 2 | 3 |
4 | 13 | 1189.64 | 18 | 14.84 | 1911 | 510 | 2.74 / 366.93 | 2 | 3 |
5 | 13 | 595.56 | 18 | 14.95 | 1137 | 306 | 3.05 / 367.24 | 2 | 3 |
6 | 13 | 35.08 | 18 | 15.08 | 377 | 102 | 3.15 / 367.34 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.05 | 307 | 762 | 3.91 / 368.10 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 33 | 15.00 | 459 | 227 | 0.23 / 360.55 | 2 | 2 |
2 | 7 | 2005.32 | 32 | 14.84 | 2921 | 1387 | 1.61 / 361.94 | 2 | 2 |
3 | 13 | 1602.80 | 18 | 14.83 | 2442 | 652 | 2.27 / 362.59 | 2 | 3 |
4 | 13 | 1065.00 | 18 | 14.87 | 1748 | 468 | 2.73 / 363.06 | 2 | 3 |
5 | 13 | 500.72 | 18 | 14.97 | 995 | 268 | 3.00 / 363.33 | 2 | 3 |
6 | 13 | 34.72 | 18 | 15.09 | 371 | 101 | 3.10 / 363.43 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.04 | 307 | 762 | 3.86 / 364.19 | 2 | 6 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 33 | 14.99 | 472 | 233 | 0.23 / 356.63 | 2 | 3 |
2 | 7 | 2002.84 | 31 | 14.84 | 2922 | 1344 | 1.58 / 357.97 | 2 | 3 |
3 | 13 | 1729.16 | 18 | 14.80 | 2601 | 693 | 2.27 / 358.66 | 2 | 3 |
4 | 13 | 1146.68 | 18 | 14.85 | 1869 | 500 | 2.77 / 359.16 | 2 | 3 |
5 | 13 | 578.40 | 18 | 14.96 | 1100 | 296 | 3.07 / 359.46 | 2 | 3 |
6 | 13 | 29.12 | 18 | 15.07 | 366 | 99 | 3.17 / 359.56 | 2 | 3 |
7 | 8 | 0.28 | 165 | 15.04 | 308 | 764 | 3.93 / 360.32 | 2 | 6 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 33 | 14.98 | 462 | 228 | 0.23 / 352.68 | 2 | 3 |
2 | 7 | 2010.84 | 31 | 14.83 | 2934 | 1349 | 1.58 / 354.03 | 2 | 3 |
3 | 13 | 1736.08 | 18 | 14.81 | 2609 | 696 | 2.27 / 354.72 | 2 | 3 |
4 | 13 | 1166.04 | 18 | 14.85 | 1888 | 505 | 2.78 / 355.23 | 2 | 3 |
5 | 13 | 588.20 | 18 | 14.96 | 1117 | 301 | 3.08 / 355.53 | 2 | 3 |
6 | 13 | 24.60 | 18 | 15.08 | 362 | 98 | 3.18 / 355.63 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.05 | 309 | 767 | 3.94 / 356.39 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 33 | 14.99 | 450 | 223 | 0.22 / 348.73 | 2 | 2 |
2 | 7 | 2004.68 | 31 | 14.85 | 2926 | 1347 | 1.57 / 350.08 | 2 | 3 |
3 | 13 | 1740.64 | 18 | 14.82 | 2620 | 699 | 2.27 / 350.78 | 2 | 3 |
4 | 13 | 1166.68 | 18 | 14.87 | 1886 | 505 | 2.77 / 351.28 | 2 | 3 |
5 | 13 | 589.24 | 18 | 14.95 | 1137 | 306 | 3.08 / 351.59 | 2 | 3 |
6 | 13 | 23.88 | 18 | 15.08 | 351 | 95 | 3.17 / 351.68 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.04 | 308 | 764 | 3.94 / 352.45 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 33 | 15.00 | 479 | 237 | 0.24 / 344.80 | 2 | 3 |
2 | 7 | 2005.60 | 31 | 14.84 | 2916 | 1341 | 1.58 / 346.15 | 2 | 3 |
3 | 13 | 1730.68 | 18 | 14.81 | 2614 | 697 | 2.28 / 346.84 | 2 | 2 |
4 | 13 | 1168.88 | 18 | 14.87 | 1888 | 505 | 2.78 / 347.35 | 2 | 3 |
5 | 13 | 594.44 | 18 | 14.95 | 1122 | 302 | 3.08 / 347.65 | 2 | 3 |
6 | 13 | 25.28 | 18 | 15.08 | 355 | 96 | 3.18 / 347.75 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.04 | 308 | 764 | 3.94 / 348.51 | 2 | 9 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 33 | 15.01 | 464 | 230 | 0.23 / 340.90 | 2 | 3 |
2 | 7 | 2005.28 | 31 | 14.84 | 2926 | 1346 | 1.58 / 342.25 | 2 | 3 |
3 | 13 | 1732.00 | 18 | 14.83 | 2609 | 696 | 2.27 / 342.94 | 2 | 3 |
4 | 13 | 1275.52 | 18 | 14.84 | 2027 | 541 | 2.81 / 343.48 | 2 | 3 |
5 | 13 | 667.32 | 18 | 14.94 | 1217 | 327 | 3.14 / 343.81 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.06 | 304 | 755 | 3.90 / 344.57 | 2 | 3 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 33 | 15.01 | 462 | 229 | 0.23 / 336.87 | 2 | 2 |
2 | 7 | 2004.64 | 31 | 14.84 | 2908 | 1338 | 1.57 / 338.21 | 2 | 3 |
3 | 13 | 1735.20 | 18 | 14.81 | 2621 | 699 | 2.27 / 338.91 | 2 | 3 |
4 | 13 | 1281.88 | 18 | 14.85 | 2038 | 545 | 2.81 / 339.45 | 2 | 3 |
5 | 13 | 545.12 | 18 | 14.98 | 1060 | 286 | 3.10 / 339.74 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.07 | 309 | 768 | 3.86 / 340.51 | 2 | 4 |
7 | 14 | -0.04 | 35 | 15.04 | 309 | 163 | 4.03 / 340.67 | 3 | 9 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 33 | 15.01 | 463 | 229 | 0.23 / 333.06 | 2 | 3 |
2 | 7 | 2011.08 | 31 | 14.85 | 2936 | 1352 | 1.58 / 334.41 | 2 | 3 |
3 | 13 | 1734.60 | 18 | 14.83 | 2617 | 699 | 2.28 / 335.11 | 2 | 3 |
4 | 13 | 1152.96 | 18 | 14.87 | 1860 | 498 | 2.78 / 335.61 | 2 | 3 |
5 | 13 | 452.40 | 18 | 15.00 | 933 | 252 | 3.03 / 335.86 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.06 | 314 | 780 | 3.81 / 336.64 | 2 | 4 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 15.00 | 469 | 232 | 0.23 / 329.11 | 2 | 2 |
2 | 7 | 2012.76 | 31 | 14.86 | 2938 | 1353 | 1.59 / 330.47 | 2 | 2 |
3 | 13 | 1742.48 | 18 | 14.83 | 2629 | 702 | 2.29 / 331.17 | 2 | 3 |
4 | 13 | 1149.56 | 18 | 14.87 | 1877 | 502 | 2.79 / 331.67 | 2 | 3 |
5 | 13 | 566.68 | 18 | 14.98 | 1111 | 300 | 3.09 / 331.97 | 2 | 3 |
6 | 13 | 25.96 | 18 | 15.09 | 357 | 97 | 3.19 / 332.07 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.06 | 309 | 768 | 3.95 / 332.83 | 2 | 6 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 33 | 15.01 | 458 | 227 | 0.23 / 325.23 | 2 | 2 |
2 | 7 | 2011.48 | 31 | 14.85 | 2951 | 1358 | 1.59 / 326.59 | 2 | 3 |
3 | 13 | 1750.80 | 18 | 14.82 | 2640 | 704 | 2.29 / 327.30 | 2 | 3 |
4 | 13 | 1178.28 | 18 | 14.86 | 1897 | 507 | 2.80 / 327.80 | 2 | 3 |
5 | 13 | 606.40 | 18 | 14.96 | 1139 | 307 | 3.10 / 328.11 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.07 | 309 | 768 | 3.87 / 328.88 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 33 | 15.02 | 472 | 234 | 0.23 / 321.38 | 2 | 2 |
2 | 7 | 2012.48 | 32 | 14.84 | 2939 | 1396 | 1.63 / 322.77 | 2 | 2 |
3 | 13 | 1604.84 | 18 | 14.84 | 2450 | 654 | 2.28 / 323.43 | 2 | 3 |
4 | 13 | 1175.88 | 18 | 14.86 | 1901 | 508 | 2.79 / 323.94 | 2 | 3 |
5 | 13 | 604.72 | 18 | 14.96 | 1137 | 306 | 3.10 / 324.24 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.07 | 308 | 766 | 3.86 / 325.01 | 2 | 6 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 33 | 15.04 | 463 | 230 | 0.23 / 317.60 | 2 | 2 |
2 | 7 | 2006.92 | 31 | 14.84 | 2936 | 1351 | 1.58 / 318.95 | 2 | 3 |
3 | 13 | 1602.32 | 18 | 14.84 | 2469 | 660 | 2.24 / 319.61 | 2 | 3 |
4 | 13 | 1174.56 | 18 | 14.87 | 1906 | 510 | 2.75 / 320.12 | 2 | 3 |
5 | 13 | 462.00 | 18 | 15.00 | 945 | 255 | 3.01 / 320.38 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.07 | 308 | 766 | 3.77 / 321.14 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 33 | 15.01 | 477 | 236 | 0.24 / 313.78 | 2 | 2 |
2 | 7 | 2003.64 | 31 | 14.86 | 2929 | 1349 | 1.59 / 315.13 | 2 | 2 |
3 | 13 | 1603.00 | 18 | 14.84 | 2451 | 655 | 2.24 / 315.78 | 2 | 3 |
4 | 13 | 1184.56 | 18 | 14.86 | 1907 | 510 | 2.75 / 316.29 | 2 | 3 |
5 | 13 | 599.20 | 18 | 14.96 | 1134 | 305 | 3.06 / 316.60 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.07 | 312 | 776 | 3.83 / 317.37 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 33 | 15.04 | 460 | 228 | 0.23 / 310.03 | 2 | 2 |
2 | 7 | 2011.04 | 31 | 14.86 | 2943 | 1356 | 1.58 / 311.39 | 2 | 3 |
3 | 13 | 1595.36 | 18 | 14.85 | 2445 | 654 | 2.24 / 312.04 | 2 | 3 |
4 | 13 | 1057.00 | 18 | 14.90 | 1744 | 468 | 2.71 / 312.51 | 2 | 3 |
5 | 13 | 503.84 | 18 | 14.99 | 1009 | 272 | 2.98 / 312.78 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.07 | 305 | 758 | 3.74 / 313.54 | 2 | 5 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 33 | 15.03 | 466 | 231 | 0.23 / 306.19 | 2 | 3 |
2 | 7 | 2005.20 | 31 | 14.85 | 2938 | 1353 | 1.58 / 307.54 | 2 | 2 |
3 | 13 | 1729.12 | 18 | 14.84 | 2613 | 698 | 2.28 / 308.24 | 2 | 3 |
4 | 13 | 1151.24 | 18 | 14.89 | 1865 | 500 | 2.78 / 308.74 | 2 | 3 |
5 | 13 | 573.20 | 18 | 14.98 | 1100 | 297 | 3.08 / 309.03 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.09 | 310 | 772 | 3.85 / 309.80 | 2 | 7 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 33 | 15.04 | 470 | 233 | 0.23 / 302.35 | 2 | 2 |
2 | 7 | 2006.44 | 31 | 14.87 | 2931 | 1351 | 1.58 / 303.70 | 2 | 3 |
3 | 13 | 1618.24 | 18 | 14.85 | 2464 | 659 | 2.24 / 304.36 | 2 | 2 |
4 | 13 | 1185.16 | 18 | 14.89 | 1918 | 514 | 2.76 / 304.88 | 2 | 3 |
5 | 13 | 606.96 | 18 | 14.97 | 1141 | 307 | 3.06 / 305.18 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.09 | 310 | 772 | 3.84 / 305.95 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 33 | 15.04 | 467 | 232 | 0.23 / 298.60 | 2 | 2 |
2 | 7 | 2006.76 | 31 | 14.85 | 2931 | 1349 | 1.58 / 299.95 | 2 | 3 |
3 | 13 | 1602.52 | 18 | 14.85 | 2437 | 651 | 2.23 / 300.60 | 2 | 3 |
4 | 13 | 1161.72 | 18 | 14.88 | 1887 | 505 | 2.74 / 301.10 | 2 | 3 |
5 | 13 | 443.72 | 18 | 15.02 | 930 | 251 | 2.99 / 301.35 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.09 | 307 | 764 | 3.75 / 302.12 | 2 | 6 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 15.05 | 471 | 234 | 0.23 / 294.75 | 2 | 2 |
2 | 7 | 2011.56 | 32 | 14.86 | 2935 | 1396 | 1.63 / 296.14 | 2 | 3 |
3 | 13 | 1729.68 | 18 | 14.84 | 2608 | 697 | 2.33 / 296.84 | 2 | 3 |
4 | 13 | 1147.00 | 18 | 14.89 | 1871 | 501 | 2.83 / 297.34 | 2 | 3 |
5 | 13 | 444.72 | 18 | 15.03 | 924 | 250 | 3.08 / 297.59 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.09 | 311 | 774 | 3.85 / 298.36 | 2 | 6 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 33 | 15.05 | 484 | 240 | 0.24 / 290.94 | 2 | 3 |
2 | 7 | 2003.72 | 31 | 14.87 | 2928 | 1350 | 1.59 / 292.29 | 2 | 3 |
3 | 13 | 1597.40 | 18 | 14.86 | 2440 | 653 | 2.24 / 292.94 | 2 | 3 |
4 | 13 | 1170.04 | 18 | 14.89 | 1880 | 504 | 2.75 / 293.45 | 2 | 3 |
5 | 13 | 587.72 | 18 | 14.99 | 1124 | 303 | 3.05 / 293.75 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.10 | 306 | 762 | 3.81 / 294.51 | 2 | 3 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 33 | 15.04 | 462 | 229 | 0.23 / 287.06 | 2 | 2 |
2 | 7 | 2012.76 | 31 | 14.86 | 2946 | 1357 | 1.59 / 288.41 | 2 | 3 |
3 | 13 | 1733.24 | 18 | 14.84 | 2634 | 704 | 2.29 / 289.12 | 2 | 3 |
4 | 13 | 1141.68 | 18 | 14.89 | 1857 | 498 | 2.79 / 289.61 | 2 | 3 |
5 | 13 | 569.16 | 18 | 14.99 | 1098 | 296 | 3.08 / 289.91 | 2 | 4 |
6 | 8 | 0.24 | 165 | 15.10 | 317 | 790 | 3.87 / 290.70 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 33 | 15.05 | 472 | 234 | 0.23 / 283.05 | 2 | 3 |
2 | 7 | 2006.60 | 31 | 14.86 | 2927 | 1348 | 1.58 / 284.40 | 2 | 3 |
3 | 13 | 1602.96 | 18 | 14.86 | 2447 | 655 | 2.24 / 285.05 | 2 | 3 |
4 | 13 | 1186.60 | 18 | 14.87 | 1931 | 517 | 2.75 / 285.57 | 2 | 3 |
5 | 13 | 598.72 | 18 | 14.99 | 1147 | 309 | 3.06 / 285.88 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.09 | 313 | 779 | 3.84 / 286.66 | 2 | 6 |
7 | 14 | -0.08 | 35 | 15.07 | 316 | 167 | 4.01 / 286.83 | 2 | 7 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 33 | 15.06 | 473 | 235 | 0.24 / 279.23 | 2 | 2 |
2 | 7 | 2004.40 | 31 | 14.87 | 2931 | 1351 | 1.59 / 280.58 | 2 | 3 |
3 | 13 | 1607.72 | 18 | 14.87 | 2455 | 657 | 2.24 / 281.24 | 2 | 3 |
4 | 13 | 1184.56 | 18 | 14.89 | 1904 | 510 | 2.75 / 281.75 | 2 | 3 |
5 | 13 | 591.92 | 18 | 15.00 | 1125 | 304 | 3.06 / 282.05 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.10 | 308 | 767 | 3.82 / 282.82 | 2 | 5 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 33 | 15.04 | 481 | 239 | 0.24 / 275.38 | 2 | 2 |
2 | 7 | 2011.84 | 31 | 14.87 | 2933 | 1352 | 1.59 / 276.74 | 2 | 3 |
3 | 13 | 1615.84 | 18 | 14.86 | 2459 | 658 | 2.25 / 277.39 | 2 | 3 |
4 | 13 | 1200.60 | 18 | 14.88 | 1933 | 518 | 2.77 / 277.91 | 2 | 3 |
5 | 13 | 600.60 | 18 | 15.00 | 1137 | 307 | 3.07 / 278.22 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.11 | 310 | 773 | 3.85 / 278.99 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 33 | 15.07 | 462 | 230 | 0.23 / 271.25 | 2 | 2 |
2 | 7 | 2003.96 | 31 | 14.89 | 2916 | 1346 | 1.58 / 272.60 | 2 | 3 |
3 | 13 | 1746.96 | 18 | 14.85 | 2624 | 701 | 2.28 / 273.30 | 2 | 2 |
4 | 13 | 1296.08 | 18 | 14.88 | 2048 | 549 | 2.83 / 273.85 | 2 | 3 |
5 | 13 | 675.84 | 18 | 14.98 | 1234 | 333 | 3.16 / 274.18 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.10 | 319 | 795 | 3.95 / 274.98 | 2 | 4 |
7 | 14 | 0.28 | 35 | 15.08 | 320 | 169 | 4.12 / 275.15 | 2 | 8 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 33 | 15.09 | 480 | 239 | 0.24 / 267.27 | 2 | 2 |
2 | 7 | 2012.40 | 31 | 14.88 | 2936 | 1354 | 1.59 / 268.63 | 2 | 2 |
3 | 13 | 1739.04 | 18 | 14.85 | 2617 | 700 | 2.29 / 269.33 | 2 | 3 |
4 | 13 | 1139.32 | 18 | 14.91 | 1856 | 498 | 2.79 / 269.83 | 2 | 3 |
5 | 13 | 439.64 | 18 | 15.06 | 919 | 249 | 3.04 / 270.08 | 2 | 3 |
6 | 8 | 0.44 | 165 | 15.12 | 313 | 781 | 3.82 / 270.86 | 2 | 4 |
7 | 14 | 0.44 | 35 | 15.09 | 316 | 167 | 3.99 / 271.02 | 3 | 10 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 33 | 15.09 | 468 | 233 | 0.23 / 263.56 | 2 | 2 |
2 | 7 | 1853.56 | 31 | 14.92 | 2731 | 1263 | 1.50 / 264.82 | 2 | 2 |
3 | 13 | 1593.68 | 18 | 14.89 | 2430 | 651 | 2.15 / 265.47 | 2 | 3 |
4 | 13 | 1169.28 | 18 | 14.94 | 1888 | 508 | 2.66 / 265.98 | 2 | 3 |
5 | 13 | 570.60 | 18 | 15.03 | 1097 | 297 | 2.95 / 266.28 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.12 | 304 | 758 | 3.71 / 267.04 | 2 | 5 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 33 | 15.07 | 464 | 231 | 0.23 / 260.05 | 2 | 2 |
2 | 7 | 1526.76 | 32 | 15.03 | 2332 | 1122 | 1.35 / 261.17 | 2 | 3 |
3 | 13 | 1420.52 | 18 | 15.00 | 2200 | 594 | 1.95 / 261.76 | 2 | 3 |
4 | 13 | 1152.80 | 18 | 14.99 | 1861 | 502 | 2.45 / 262.26 | 2 | 3 |
5 | 13 | 545.20 | 18 | 15.08 | 1054 | 286 | 2.73 / 262.55 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.15 | 310 | 775 | 3.51 / 263.33 | 2 | 6 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 33 | 15.08 | 466 | 232 | 0.23 / 255.94 | 2 | 2 |
2 | 7 | 1942.12 | 31 | 14.89 | 2847 | 1314 | 1.55 / 257.25 | 2 | 3 |
3 | 13 | 1672.24 | 18 | 14.88 | 2534 | 679 | 2.22 / 257.93 | 2 | 3 |
4 | 13 | 1218.64 | 18 | 14.92 | 1945 | 522 | 2.75 / 258.45 | 2 | 3 |
5 | 13 | 622.60 | 18 | 15.02 | 1165 | 315 | 3.06 / 258.77 | 2 | 3 |
6 | 13 | 60.48 | 18 | 15.17 | 394 | 108 | 3.17 / 258.88 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.12 | 311 | 776 | 3.95 / 259.65 | 2 | 5 |
8 | 14 | 0.16 | 35 | 15.11 | 311 | 164 | 4.11 / 259.82 | 2 | 7 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 33 | 15.07 | 471 | 234 | 0.23 / 252.08 | 2 | 2 |
2 | 7 | 2004.24 | 31 | 14.89 | 2928 | 1352 | 1.59 / 253.43 | 2 | 3 |
3 | 13 | 1612.32 | 18 | 14.89 | 2461 | 660 | 2.25 / 254.09 | 2 | 3 |
4 | 13 | 1067.84 | 18 | 14.94 | 1758 | 473 | 2.72 / 254.56 | 2 | 3 |
5 | 13 | 504.60 | 18 | 15.07 | 1009 | 274 | 2.99 / 254.84 | 2 | 3 |
6 | 13 | 37.04 | 18 | 15.16 | 369 | 101 | 3.09 / 254.94 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.12 | 308 | 768 | 3.86 / 255.71 | 2 | 8 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 33 | 15.08 | 474 | 236 | 0.24 / 248.12 | 2 | 3 |
2 | 7 | 2008.72 | 31 | 14.90 | 2954 | 1364 | 1.60 / 249.48 | 2 | 2 |
3 | 13 | 1604.44 | 18 | 14.88 | 2462 | 659 | 2.26 / 250.14 | 2 | 5 |
4 | 13 | 1182.04 | 18 | 14.91 | 1917 | 514 | 2.77 / 250.65 | 2 | 3 |
5 | 13 | 583.52 | 18 | 15.02 | 1121 | 303 | 3.08 / 250.96 | 2 | 3 |
6 | 13 | 52.16 | 18 | 15.16 | 399 | 109 | 3.19 / 251.07 | 2 | 3 |
7 | 8 | 0.32 | 165 | 15.13 | 312 | 779 | 3.97 / 251.85 | 2 | 5 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 15.08 | 459 | 228 | 0.23 / 244.18 | 2 | 2 |
2 | 7 | 2013.44 | 31 | 14.89 | 2935 | 1355 | 1.58 / 245.53 | 2 | 3 |
3 | 13 | 1605.84 | 18 | 14.90 | 2460 | 660 | 2.24 / 246.19 | 2 | 4 |
4 | 13 | 1183.68 | 18 | 14.92 | 1915 | 514 | 2.76 / 246.71 | 2 | 3 |
5 | 13 | 458.88 | 18 | 15.07 | 967 | 262 | 3.02 / 246.97 | 2 | 3 |
6 | 13 | 30.76 | 18 | 15.16 | 380 | 104 | 3.12 / 247.07 | 2 | 3 |
7 | 8 | -0.16 | 165 | 15.13 | 324 | 809 | 3.93 / 247.88 | 2 | 6 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 33 | 15.08 | 458 | 228 | 0.23 / 240.09 | 2 | 2 |
2 | 7 | 2006.04 | 32 | 14.90 | 2928 | 1396 | 1.62 / 241.48 | 2 | 3 |
3 | 13 | 1742.00 | 18 | 14.87 | 2626 | 703 | 2.33 / 242.18 | 2 | 3 |
4 | 13 | 1154.08 | 18 | 14.92 | 1861 | 500 | 2.83 / 242.68 | 2 | 3 |
5 | 13 | 435.64 | 18 | 15.08 | 899 | 244 | 3.07 / 242.93 | 2 | 3 |
6 | 13 | 13.84 | 18 | 15.17 | 336 | 92 | 3.16 / 243.02 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.14 | 307 | 767 | 3.93 / 243.79 | 2 | 11 |
8 | 14 | 0.12 | 35 | 15.11 | 305 | 161 | 4.09 / 243.95 | 2 | 8 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 33 | 15.10 | 470 | 234 | 0.23 / 236.22 | 2 | 2 |
2 | 7 | 2012.20 | 31 | 14.89 | 2928 | 1352 | 1.59 / 237.58 | 2 | 3 |
3 | 13 | 1607.08 | 18 | 14.88 | 2459 | 659 | 2.24 / 238.23 | 2 | 3 |
4 | 13 | 1164.96 | 18 | 14.93 | 1882 | 506 | 2.75 / 238.74 | 2 | 3 |
5 | 13 | 454.72 | 18 | 15.08 | 932 | 253 | 3.00 / 238.99 | 2 | 3 |
6 | 13 | 29.88 | 18 | 15.17 | 358 | 98 | 3.10 / 239.09 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.14 | 307 | 767 | 3.87 / 239.86 | 2 | 8 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 33 | 15.10 | 470 | 234 | 0.23 / 232.28 | 2 | 3 |
2 | 7 | 2010.76 | 31 | 14.89 | 2943 | 1358 | 1.59 / 233.64 | 2 | 3 |
3 | 13 | 1604.96 | 18 | 14.89 | 2453 | 657 | 2.25 / 234.30 | 2 | 4 |
4 | 13 | 1177.00 | 18 | 14.92 | 1901 | 511 | 2.76 / 234.81 | 2 | 3 |
5 | 13 | 576.52 | 18 | 15.05 | 1095 | 297 | 3.06 / 235.10 | 2 | 3 |
6 | 13 | 44.12 | 18 | 15.19 | 385 | 105 | 3.16 / 235.21 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.14 | 313 | 782 | 3.94 / 235.99 | 2 | 6 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 33 | 15.11 | 477 | 238 | 0.24 / 228.38 | 2 | 2 |
2 | 7 | 2005.24 | 31 | 14.92 | 2927 | 1354 | 1.59 / 229.73 | 2 | 3 |
3 | 13 | 1611.52 | 18 | 14.91 | 2450 | 658 | 2.25 / 230.39 | 2 | 3 |
4 | 13 | 1178.04 | 18 | 14.93 | 1910 | 513 | 2.76 / 230.90 | 2 | 3 |
5 | 13 | 448.20 | 18 | 15.09 | 932 | 253 | 3.02 / 231.16 | 2 | 3 |
6 | 13 | 60.12 | 18 | 15.18 | 416 | 114 | 3.13 / 231.27 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.16 | 310 | 775 | 3.90 / 232.05 | 2 | 6 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 33 | 15.12 | 473 | 236 | 0.24 / 224.24 | 2 | 3 |
2 | 7 | 2012.12 | 31 | 14.91 | 2934 | 1356 | 1.59 / 225.59 | 2 | 3 |
3 | 13 | 1745.12 | 18 | 14.88 | 2633 | 705 | 2.30 / 226.30 | 2 | 3 |
4 | 13 | 1166.16 | 18 | 14.94 | 1889 | 508 | 2.81 / 226.81 | 2 | 3 |
5 | 13 | 594.24 | 18 | 15.07 | 1126 | 305 | 3.11 / 227.11 | 2 | 3 |
6 | 13 | 25.32 | 18 | 15.20 | 354 | 97 | 3.21 / 227.21 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.17 | 307 | 768 | 3.98 / 227.98 | 2 | 5 |
8 | 14 | -0.08 | 35 | 15.14 | 308 | 163 | 4.14 / 228.14 | 2 | 9 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 33 | 15.13 | 477 | 238 | 0.24 / 220.33 | 2 | 2 |
2 | 7 | 2009.12 | 31 | 14.91 | 2927 | 1353 | 1.59 / 221.68 | 2 | 3 |
3 | 13 | 1608.88 | 18 | 14.89 | 2465 | 661 | 2.25 / 222.34 | 2 | 5 |
4 | 13 | 1175.60 | 18 | 14.93 | 1910 | 513 | 2.77 / 222.86 | 2 | 3 |
5 | 13 | 450.08 | 18 | 15.10 | 944 | 257 | 3.02 / 223.11 | 2 | 3 |
6 | 13 | 28.36 | 18 | 15.21 | 369 | 101 | 3.12 / 223.21 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.18 | 314 | 786 | 3.91 / 224.00 | 2 | 7 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 32 | 15.14 | 466 | 226 | 0.23 / 216.45 | 2 | 2 |
2 | 7 | 2004.24 | 31 | 14.91 | 2931 | 1355 | 1.58 / 217.81 | 2 | 3 |
3 | 13 | 1610.28 | 18 | 14.90 | 2470 | 662 | 2.24 / 218.47 | 2 | 3 |
4 | 13 | 1064.76 | 18 | 14.97 | 1767 | 476 | 2.72 / 218.95 | 2 | 3 |
5 | 13 | 494.16 | 18 | 15.09 | 1005 | 273 | 2.99 / 219.22 | 2 | 3 |
6 | 13 | 35.76 | 18 | 15.20 | 370 | 101 | 3.09 / 219.32 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.17 | 308 | 771 | 3.86 / 220.09 | 2 | 8 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 32 | 15.15 | 479 | 232 | 0.23 / 212.57 | 2 | 2 |
2 | 7 | 2006.28 | 31 | 14.91 | 2935 | 1357 | 1.59 / 213.93 | 2 | 3 |
3 | 13 | 1601.60 | 18 | 14.92 | 2453 | 659 | 2.25 / 214.59 | 2 | 3 |
4 | 13 | 1065.88 | 18 | 14.99 | 1758 | 474 | 2.72 / 215.06 | 2 | 3 |
5 | 13 | 491.20 | 18 | 15.12 | 1011 | 275 | 3.00 / 215.34 | 2 | 3 |
6 | 13 | 31.44 | 18 | 15.22 | 376 | 103 | 3.10 / 215.44 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.18 | 314 | 786 | 3.89 / 216.23 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 32 | 15.16 | 479 | 232 | 0.23 / 208.77 | 2 | 2 |
2 | 7 | 2012.44 | 31 | 14.93 | 2944 | 1363 | 1.59 / 210.14 | 2 | 3 |
3 | 13 | 1616.84 | 18 | 14.92 | 2467 | 663 | 2.26 / 210.80 | 2 | 3 |
4 | 13 | 1181.32 | 18 | 14.97 | 1908 | 514 | 2.77 / 211.31 | 2 | 3 |
5 | 13 | 463.72 | 18 | 15.12 | 952 | 259 | 3.03 / 211.57 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.20 | 307 | 770 | 3.80 / 212.34 | 2 | 5 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 32 | 15.17 | 477 | 232 | 0.23 / 204.84 | 2 | 2 |
2 | 7 | 2005.76 | 31 | 14.93 | 2918 | 1351 | 1.58 / 206.20 | 2 | 2 |
3 | 13 | 1726.40 | 18 | 14.91 | 2619 | 703 | 2.28 / 206.90 | 2 | 3 |
4 | 13 | 1153.76 | 18 | 14.97 | 1880 | 507 | 2.79 / 207.40 | 2 | 3 |
5 | 13 | 452.12 | 18 | 15.14 | 921 | 251 | 3.04 / 207.66 | 2 | 3 |
6 | 13 | 32.48 | 18 | 15.23 | 373 | 102 | 3.14 / 207.76 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.20 | 312 | 782 | 3.93 / 208.54 | 2 | 7 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 32 | 15.16 | 469 | 228 | 0.23 / 200.95 | 2 | 2 |
2 | 7 | 2005.16 | 31 | 14.93 | 2926 | 1354 | 1.58 / 202.31 | 2 | 2 |
3 | 13 | 1603.52 | 18 | 14.92 | 2438 | 655 | 2.24 / 202.96 | 2 | 3 |
4 | 13 | 1165.48 | 18 | 14.97 | 1901 | 512 | 2.75 / 203.47 | 2 | 3 |
5 | 13 | 443.72 | 18 | 15.14 | 926 | 252 | 3.00 / 203.73 | 2 | 4 |
6 | 13 | 28.64 | 18 | 15.25 | 365 | 100 | 3.10 / 203.83 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.20 | 314 | 788 | 3.89 / 204.61 | 2 | 7 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 32 | 15.19 | 473 | 230 | 0.23 / 196.99 | 2 | 2 |
2 | 7 | 2007.08 | 31 | 14.94 | 2943 | 1363 | 1.59 / 198.36 | 2 | 2 |
3 | 13 | 1733.04 | 18 | 14.91 | 2624 | 704 | 2.30 / 199.06 | 2 | 3 |
4 | 13 | 1162.28 | 18 | 14.98 | 1895 | 511 | 2.81 / 199.57 | 2 | 3 |
5 | 13 | 468.16 | 18 | 15.15 | 968 | 264 | 3.07 / 199.83 | 2 | 3 |
6 | 13 | 31.16 | 18 | 15.25 | 376 | 103 | 3.18 / 199.94 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.23 | 313 | 787 | 3.96 / 200.72 | 2 | 7 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 32 | 15.18 | 471 | 229 | 0.23 / 193.17 | 2 | 2 |
2 | 7 | 2003.56 | 31 | 14.93 | 2927 | 1355 | 1.58 / 194.53 | 2 | 2 |
3 | 13 | 1614.88 | 18 | 14.93 | 2477 | 666 | 2.25 / 195.19 | 2 | 3 |
4 | 13 | 1177.40 | 18 | 14.97 | 1921 | 518 | 2.77 / 195.71 | 2 | 3 |
5 | 13 | 464.88 | 18 | 15.14 | 961 | 262 | 3.03 / 195.97 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.23 | 314 | 789 | 3.82 / 196.76 | 2 | 5 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 32 | 15.20 | 488 | 237 | 0.24 / 189.33 | 2 | 2 |
2 | 7 | 2011.56 | 31 | 14.93 | 2948 | 1364 | 1.60 / 190.69 | 2 | 3 |
3 | 13 | 1743.68 | 18 | 14.91 | 2642 | 709 | 2.31 / 191.40 | 2 | 4 |
4 | 13 | 1038.76 | 18 | 15.02 | 1734 | 469 | 2.78 / 191.87 | 2 | 3 |
5 | 13 | 480.28 | 18 | 15.16 | 980 | 267 | 3.05 / 192.14 | 2 | 5 |
6 | 8 | 0.12 | 165 | 15.24 | 321 | 807 | 3.85 / 192.94 | 2 | 7 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 32 | 15.19 | 473 | 230 | 0.23 / 185.55 | 2 | 3 |
2 | 7 | 2005.68 | 31 | 14.94 | 2920 | 1352 | 1.58 / 186.91 | 2 | 3 |
3 | 13 | 1602.96 | 18 | 14.93 | 2445 | 657 | 2.24 / 187.56 | 2 | 3 |
4 | 13 | 1064.36 | 18 | 15.01 | 1757 | 475 | 2.71 / 188.04 | 2 | 3 |
5 | 13 | 487.76 | 18 | 15.15 | 986 | 269 | 2.98 / 188.31 | 2 | 5 |
6 | 8 | 0.00 | 165 | 15.23 | 312 | 784 | 3.77 / 189.09 | 2 | 7 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 32 | 15.21 | 479 | 233 | 0.23 / 181.69 | 2 | 2 |
2 | 7 | 2006.80 | 32 | 14.93 | 2932 | 1401 | 1.63 / 183.09 | 2 | 3 |
3 | 13 | 1610.16 | 18 | 14.94 | 2458 | 661 | 2.29 / 183.75 | 2 | 3 |
4 | 13 | 1177.60 | 18 | 14.99 | 1907 | 515 | 2.81 / 184.27 | 2 | 3 |
5 | 13 | 459.84 | 18 | 15.18 | 961 | 263 | 3.07 / 184.53 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.25 | 316 | 795 | 3.87 / 185.32 | 2 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 32 | 15.20 | 467 | 227 | 0.23 / 177.89 | 2 | 2 |
2 | 7 | 2005.04 | 31 | 14.92 | 2931 | 1356 | 1.58 / 179.24 | 2 | 4 |
3 | 13 | 1604.12 | 18 | 14.94 | 2473 | 665 | 2.25 / 179.91 | 2 | 4 |
4 | 13 | 1068.52 | 18 | 15.02 | 1764 | 477 | 2.72 / 180.39 | 2 | 3 |
5 | 13 | 499.36 | 18 | 15.16 | 1007 | 275 | 3.00 / 180.66 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.24 | 316 | 795 | 3.79 / 181.46 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 32 | 15.20 | 477 | 232 | 0.23 / 174.15 | 2 | 2 |
2 | 7 | 2007.48 | 31 | 14.94 | 2934 | 1359 | 1.59 / 175.51 | 2 | 4 |
3 | 13 | 1607.32 | 18 | 14.94 | 2456 | 660 | 2.25 / 176.17 | 2 | 3 |
4 | 13 | 1063.00 | 18 | 15.02 | 1760 | 476 | 2.73 / 176.65 | 2 | 3 |
5 | 13 | 382.84 | 18 | 15.19 | 847 | 232 | 2.96 / 176.88 | 2 | 3 |
6 | 8 | 0.40 | 165 | 15.25 | 312 | 785 | 3.74 / 177.66 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 32 | 15.21 | 471 | 229 | 0.23 / 170.32 | 2 | 2 |
2 | 7 | 2005.00 | 32 | 14.94 | 2932 | 1402 | 1.63 / 171.72 | 2 | 3 |
3 | 13 | 1596.52 | 18 | 14.95 | 2451 | 660 | 2.29 / 172.38 | 2 | 3 |
4 | 13 | 1051.12 | 18 | 15.05 | 1745 | 473 | 2.76 / 172.85 | 2 | 3 |
5 | 13 | 489.04 | 18 | 15.18 | 999 | 273 | 3.04 / 173.13 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.26 | 314 | 791 | 3.83 / 173.92 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 32 | 15.23 | 488 | 238 | 0.24 / 166.21 | 2 | 2 |
2 | 7 | 2009.96 | 31 | 14.94 | 2942 | 1363 | 1.60 / 167.58 | 2 | 3 |
3 | 13 | 1605.48 | 18 | 14.95 | 2458 | 661 | 2.26 / 168.24 | 2 | 3 |
4 | 13 | 1170.48 | 18 | 15.01 | 1917 | 518 | 2.78 / 168.76 | 2 | 3 |
5 | 13 | 446.24 | 18 | 15.20 | 947 | 259 | 3.04 / 169.01 | 2 | 3 |
6 | 13 | 15.20 | 18 | 15.30 | 360 | 99 | 3.14 / 169.11 | 2 | 3 |
7 | 8 | -0.20 | 165 | 15.26 | 321 | 808 | 3.95 / 169.92 | 2 | 6 |
8 | 14 | -0.20 | 35 | 15.23 | 318 | 170 | 4.12 / 170.09 | 2 | 8 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 32 | 15.23 | 495 | 241 | 0.24 / 162.35 | 2 | 2 |
2 | 7 | 2009.76 | 32 | 14.95 | 2936 | 1405 | 1.65 / 163.76 | 2 | 3 |
3 | 13 | 1603.64 | 18 | 14.97 | 2446 | 659 | 2.30 / 164.42 | 2 | 3 |
4 | 13 | 1053.04 | 18 | 15.05 | 1748 | 474 | 2.78 / 164.89 | 2 | 3 |
5 | 13 | 484.56 | 18 | 15.19 | 996 | 272 | 3.05 / 165.16 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.28 | 322 | 812 | 3.86 / 165.98 | 2 | 7 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 32 | 15.23 | 481 | 234 | 0.23 / 158.53 | 2 | 2 |
2 | 7 | 2008.84 | 31 | 14.95 | 2941 | 1363 | 1.60 / 159.89 | 2 | 3 |
3 | 13 | 1598.16 | 18 | 14.97 | 2447 | 659 | 2.26 / 160.55 | 2 | 3 |
4 | 13 | 1049.28 | 18 | 15.05 | 1763 | 478 | 2.73 / 161.03 | 2 | 3 |
5 | 13 | 470.72 | 18 | 15.20 | 979 | 268 | 3.00 / 161.30 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.27 | 323 | 814 | 3.82 / 162.11 | 2 | 4 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 32 | 15.22 | 496 | 242 | 0.24 / 154.48 | 2 | 2 |
2 | 7 | 2010.00 | 32 | 14.95 | 2945 | 1409 | 1.65 / 155.89 | 2 | 3 |
3 | 13 | 1604.40 | 18 | 14.95 | 2459 | 662 | 2.31 / 156.55 | 2 | 3 |
4 | 13 | 1054.04 | 18 | 15.05 | 1756 | 476 | 2.79 / 157.03 | 2 | 3 |
5 | 13 | 492.12 | 18 | 15.19 | 1013 | 277 | 3.06 / 157.30 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.28 | 326 | 822 | 3.89 / 158.12 | 2 | 6 |
7 | 14 | 0.00 | 35 | 15.25 | 324 | 173 | 4.06 / 158.30 | 2 | 11 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 32 | 15.21 | 487 | 237 | 0.24 / 150.59 | 2 | 2 |
2 | 7 | 2011.44 | 32 | 14.95 | 2942 | 1407 | 1.64 / 151.99 | 2 | 3 |
3 | 13 | 1610.00 | 18 | 14.96 | 2459 | 662 | 2.31 / 152.66 | 2 | 3 |
4 | 13 | 1054.60 | 18 | 15.05 | 1754 | 475 | 2.78 / 153.13 | 2 | 3 |
5 | 13 | 493.80 | 18 | 15.18 | 1003 | 274 | 3.06 / 153.41 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.28 | 330 | 832 | 3.89 / 154.24 | 2 | 3 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 32 | 15.22 | 484 | 236 | 0.24 / 146.48 | 2 | 2 |
2 | 7 | 2003.44 | 31 | 14.97 | 2932 | 1361 | 1.60 / 147.84 | 2 | 3 |
3 | 13 | 1613.72 | 18 | 14.96 | 2468 | 665 | 2.26 / 148.50 | 2 | 3 |
4 | 13 | 1184.08 | 18 | 15.02 | 1918 | 519 | 2.78 / 149.02 | 2 | 3 |
5 | 13 | 468.48 | 18 | 15.20 | 967 | 265 | 3.04 / 149.29 | 2 | 3 |
6 | 13 | 24.44 | 18 | 15.31 | 356 | 98 | 3.14 / 149.38 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.27 | 316 | 796 | 3.94 / 150.18 | 2 | 5 |
8 | 14 | 0.08 | 35 | 15.25 | 317 | 169 | 4.11 / 150.35 | 2 | 11 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 32 | 15.22 | 480 | 234 | 0.23 / 142.62 | 2 | 2 |
2 | 7 | 2009.08 | 31 | 14.96 | 2944 | 1365 | 1.60 / 143.99 | 2 | 4 |
3 | 13 | 1596.24 | 18 | 14.96 | 2442 | 658 | 2.26 / 144.64 | 2 | 3 |
4 | 13 | 1166.60 | 18 | 15.03 | 1886 | 510 | 2.77 / 145.15 | 2 | 3 |
5 | 13 | 566.52 | 18 | 15.16 | 1095 | 299 | 3.07 / 145.45 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.28 | 313 | 789 | 3.85 / 146.24 | 2 | 10 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 32 | 15.24 | 473 | 231 | 0.23 / 138.59 | 2 | 2 |
2 | 7 | 2011.88 | 32 | 14.95 | 2936 | 1405 | 1.64 / 139.99 | 2 | 3 |
3 | 13 | 1615.20 | 18 | 14.96 | 2466 | 664 | 2.30 / 140.66 | 2 | 3 |
4 | 13 | 1058.08 | 18 | 15.06 | 1760 | 477 | 2.78 / 141.14 | 2 | 3 |
5 | 13 | 495.00 | 18 | 15.19 | 1008 | 276 | 3.05 / 141.41 | 2 | 3 |
6 | 8 | 1.24 | 165 | 15.29 | 319 | 805 | 3.86 / 142.22 | 2 | 5 |
7 | 14 | 1.24 | 35 | 15.26 | 320 | 171 | 4.03 / 142.39 | 2 | 7 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.72 | 32 | 15.23 | 486 | 237 | 0.24 / 134.76 | 2 | 2 |
2 | 7 | 2008.08 | 31 | 14.99 | 2937 | 1365 | 1.60 / 136.13 | 2 | 3 |
3 | 13 | 1605.72 | 18 | 14.97 | 2462 | 663 | 2.27 / 136.79 | 2 | 3 |
4 | 13 | 1184.96 | 18 | 15.04 | 1914 | 518 | 2.78 / 137.31 | 2 | 3 |
5 | 13 | 451.92 | 18 | 15.22 | 935 | 256 | 3.04 / 137.57 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.30 | 314 | 793 | 3.83 / 138.36 | 2 | 7 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 32 | 15.23 | 487 | 237 | 0.24 / 130.91 | 2 | 2 |
2 | 7 | 2010.12 | 31 | 14.96 | 2939 | 1363 | 1.60 / 132.27 | 2 | 3 |
3 | 13 | 1602.64 | 18 | 14.97 | 2441 | 658 | 2.26 / 132.93 | 2 | 3 |
4 | 13 | 1163.20 | 18 | 15.04 | 1879 | 509 | 2.77 / 133.44 | 2 | 3 |
5 | 13 | 557.16 | 18 | 15.19 | 1086 | 297 | 3.06 / 133.73 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.28 | 315 | 794 | 3.86 / 134.53 | 2 | 7 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 32 | 15.25 | 469 | 229 | 0.23 / 127.12 | 2 | 2 |
2 | 7 | 2004.80 | 31 | 14.96 | 2927 | 1357 | 1.59 / 128.48 | 2 | 3 |
3 | 13 | 1595.92 | 18 | 14.97 | 2453 | 661 | 2.25 / 129.14 | 2 | 3 |
4 | 13 | 1040.68 | 18 | 15.08 | 1733 | 470 | 2.72 / 129.61 | 2 | 3 |
5 | 13 | 459.12 | 18 | 15.22 | 953 | 261 | 2.98 / 129.87 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.29 | 317 | 800 | 3.78 / 130.67 | 2 | 4 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 32 | 15.25 | 489 | 239 | 0.24 / 123.27 | 2 | 2 |
2 | 7 | 2004.64 | 31 | 14.96 | 2935 | 1361 | 1.60 / 124.63 | 2 | 3 |
3 | 13 | 1600.28 | 18 | 14.99 | 2456 | 663 | 2.26 / 125.30 | 2 | 3 |
4 | 13 | 1164.88 | 18 | 15.05 | 1888 | 511 | 2.77 / 125.81 | 2 | 3 |
5 | 13 | 557.60 | 18 | 15.20 | 1081 | 296 | 3.07 / 126.10 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.29 | 312 | 787 | 3.86 / 126.89 | 2 | 7 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 32 | 15.25 | 475 | 232 | 0.23 / 119.44 | 2 | 2 |
2 | 7 | 2010.04 | 31 | 14.96 | 2936 | 1362 | 1.59 / 120.80 | 2 | 3 |
3 | 13 | 1602.72 | 18 | 14.99 | 2444 | 659 | 2.25 / 121.46 | 2 | 3 |
4 | 13 | 1162.36 | 18 | 15.05 | 1882 | 510 | 2.76 / 121.97 | 2 | 3 |
5 | 13 | 435.20 | 18 | 15.23 | 918 | 252 | 3.01 / 122.23 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.31 | 320 | 808 | 3.82 / 123.03 | 2 | 4 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 32 | 15.27 | 480 | 235 | 0.23 / 115.65 | 2 | 2 |
2 | 7 | 2007.40 | 31 | 14.97 | 2936 | 1363 | 1.60 / 117.02 | 2 | 3 |
3 | 13 | 1591.80 | 18 | 15.00 | 2434 | 657 | 2.25 / 117.67 | 2 | 3 |
4 | 13 | 1037.24 | 18 | 15.08 | 1727 | 469 | 2.72 / 118.14 | 2 | 4 |
5 | 13 | 472.40 | 18 | 15.21 | 976 | 267 | 2.99 / 118.41 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.29 | 318 | 802 | 3.79 / 119.21 | 2 | 4 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 32 | 15.26 | 485 | 237 | 0.24 / 111.80 | 2 | 2 |
2 | 7 | 2004.04 | 31 | 14.99 | 2934 | 1363 | 1.60 / 113.16 | 2 | 3 |
3 | 13 | 1726.40 | 18 | 14.97 | 2608 | 703 | 2.30 / 113.87 | 2 | 3 |
4 | 13 | 1144.84 | 18 | 15.07 | 1867 | 506 | 2.81 / 114.37 | 2 | 3 |
5 | 13 | 440.52 | 18 | 15.24 | 925 | 254 | 3.06 / 114.63 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.31 | 314 | 793 | 3.86 / 115.42 | 2 | 7 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 32 | 15.27 | 472 | 231 | 0.23 / 107.85 | 2 | 2 |
2 | 7 | 2005.12 | 32 | 15.00 | 2920 | 1402 | 1.63 / 109.26 | 2 | 3 |
3 | 13 | 1732.32 | 18 | 14.97 | 2605 | 702 | 2.33 / 109.96 | 2 | 2 |
4 | 13 | 1137.36 | 18 | 15.08 | 1853 | 503 | 2.84 / 110.46 | 2 | 3 |
5 | 13 | 557.56 | 18 | 15.22 | 1087 | 298 | 3.13 / 110.76 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.31 | 318 | 803 | 3.94 / 111.56 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 31 | 15.26 | 471 | 223 | 0.22 / 104.06 | 2 | 2 |
2 | 7 | 2005.64 | 31 | 14.98 | 2919 | 1356 | 1.58 / 105.41 | 2 | 3 |
3 | 13 | 1600.76 | 18 | 14.99 | 2439 | 658 | 2.24 / 106.07 | 2 | 3 |
4 | 13 | 1033.56 | 18 | 15.10 | 1717 | 467 | 2.70 / 106.54 | 2 | 3 |
5 | 13 | 478.84 | 18 | 15.23 | 981 | 269 | 2.97 / 106.81 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.31 | 323 | 816 | 3.79 / 107.62 | 2 | 5 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 31 | 15.27 | 474 | 224 | 0.22 / 100.22 | 2 | 2 |
2 | 7 | 2007.08 | 31 | 14.98 | 2934 | 1362 | 1.59 / 101.58 | 2 | 3 |
3 | 13 | 1594.00 | 18 | 15.01 | 2428 | 656 | 2.24 / 102.24 | 2 | 3 |
4 | 13 | 1155.68 | 18 | 15.09 | 1873 | 509 | 2.75 / 102.75 | 2 | 3 |
5 | 13 | 546.52 | 18 | 15.23 | 1074 | 294 | 3.05 / 103.04 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.31 | 314 | 793 | 3.84 / 103.84 | 2 | 9 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 31 | 15.29 | 470 | 223 | 0.22 / 96.41 | 2 | 2 |
2 | 7 | 2003.00 | 32 | 14.98 | 2920 | 1400 | 1.62 / 97.81 | 2 | 3 |
3 | 13 | 1595.28 | 18 | 15.00 | 2434 | 657 | 2.28 / 98.46 | 2 | 3 |
4 | 13 | 1144.12 | 18 | 15.08 | 1863 | 506 | 2.79 / 98.97 | 2 | 3 |
5 | 13 | 432.28 | 18 | 15.25 | 909 | 250 | 3.03 / 99.22 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.31 | 308 | 778 | 3.81 / 100.00 | 2 | 4 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 31 | 15.28 | 453 | 215 | 0.21 / 92.44 | 2 | 2 |
2 | 7 | 2004.28 | 31 | 15.00 | 2928 | 1362 | 1.58 / 93.80 | 2 | 3 |
3 | 13 | 1598.12 | 18 | 15.01 | 2429 | 656 | 2.23 / 94.45 | 2 | 2 |
4 | 13 | 1164.24 | 18 | 15.09 | 1889 | 513 | 2.75 / 94.97 | 2 | 3 |
5 | 13 | 580.64 | 18 | 15.20 | 1122 | 307 | 3.05 / 95.27 | 2 | 3 |
6 | 13 | 26.40 | 18 | 15.36 | 376 | 104 | 3.16 / 95.38 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.31 | 319 | 806 | 3.96 / 96.18 | 2 | 7 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 31 | 15.28 | 459 | 217 | 0.22 / 88.60 | 2 | 2 |
2 | 7 | 2008.16 | 31 | 14.99 | 2949 | 1370 | 1.59 / 89.97 | 2 | 3 |
3 | 13 | 1596.96 | 18 | 15.03 | 2430 | 657 | 2.25 / 90.63 | 2 | 3 |
4 | 13 | 1033.56 | 18 | 15.12 | 1714 | 466 | 2.71 / 91.10 | 2 | 3 |
5 | 13 | 461.56 | 18 | 15.26 | 945 | 260 | 2.97 / 91.36 | 2 | 3 |
6 | 13 | 26.20 | 18 | 15.35 | 353 | 98 | 3.07 / 91.46 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.33 | 303 | 766 | 3.84 / 92.22 | 2 | 6 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 31 | 15.28 | 467 | 221 | 0.22 / 84.70 | 2 | 2 |
2 | 3 | 1017.40 | 1 | 15.38 | 1736 | 27 | 0.25 / 84.72 | 2 | 2 |
3 | 7 | 2005.60 | 31 | 15.02 | 2923 | 1361 | 1.61 / 86.08 | 2 | 2 |
4 | 13 | 1603.32 | 18 | 15.02 | 2447 | 662 | 2.27 / 86.74 | 2 | 3 |
5 | 13 | 1176.08 | 18 | 15.08 | 1889 | 513 | 2.78 / 87.26 | 2 | 3 |
6 | 13 | 460.60 | 18 | 15.25 | 940 | 258 | 3.04 / 87.52 | 2 | 3 |
7 | 13 | 29.76 | 18 | 15.37 | 359 | 99 | 3.14 / 87.62 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.33 | 305 | 771 | 3.91 / 88.39 | 2 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 31 | 15.29 | 452 | 214 | 0.21 / 80.92 | 2 | 3 |
2 | 7 | 2008.92 | 31 | 15.00 | 2928 | 1362 | 1.58 / 82.28 | 2 | 3 |
3 | 13 | 1602.96 | 18 | 15.03 | 2438 | 660 | 2.24 / 82.94 | 2 | 3 |
4 | 13 | 1049.80 | 18 | 15.12 | 1720 | 468 | 2.70 / 83.40 | 2 | 3 |
5 | 13 | 352.16 | 18 | 15.31 | 782 | 216 | 2.92 / 83.62 | 2 | 3 |
6 | 13 | 18.64 | 18 | 15.37 | 328 | 91 | 3.01 / 83.71 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.33 | 302 | 764 | 3.77 / 84.47 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 31 | 15.30 | 446 | 212 | 0.21 / 77.08 | 2 | 2 |
2 | 7 | 2006.64 | 31 | 15.00 | 2934 | 1364 | 1.58 / 78.45 | 2 | 3 |
3 | 13 | 1729.76 | 18 | 15.01 | 2588 | 699 | 2.28 / 79.15 | 2 | 2 |
4 | 13 | 1022.80 | 18 | 15.13 | 1689 | 460 | 2.74 / 79.61 | 2 | 3 |
5 | 13 | 455.36 | 18 | 15.26 | 919 | 252 | 2.99 / 79.86 | 2 | 3 |
6 | 13 | 27.04 | 18 | 15.36 | 346 | 96 | 3.08 / 79.95 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.34 | 295 | 747 | 3.83 / 80.70 | 2 | 8 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 31 | 15.29 | 450 | 213 | 0.21 / 73.15 | 2 | 2 |
2 | 7 | 2005.96 | 32 | 15.02 | 2915 | 1401 | 1.61 / 74.55 | 2 | 3 |
3 | 13 | 1596.88 | 18 | 15.04 | 2422 | 656 | 2.27 / 75.21 | 2 | 3 |
4 | 13 | 1047.80 | 18 | 15.13 | 1725 | 470 | 2.74 / 75.68 | 2 | 3 |
5 | 13 | 460.52 | 18 | 15.26 | 932 | 256 | 3.00 / 75.93 | 2 | 3 |
6 | 13 | 63.12 | 18 | 15.36 | 394 | 109 | 3.10 / 76.04 | 2 | 3 |
7 | 13 | 15.16 | 18 | 15.36 | 326 | 90 | 3.19 / 76.13 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.32 | 292 | 738 | 3.93 / 76.87 | 2 | 9 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 31 | 15.29 | 443 | 210 | 0.21 / 69.38 | 2 | 2 |
2 | 7 | 2003.48 | 31 | 15.04 | 2935 | 1368 | 1.58 / 70.75 | 2 | 3 |
3 | 13 | 1603.08 | 18 | 15.06 | 2417 | 655 | 2.23 / 71.40 | 2 | 2 |
4 | 13 | 1174.12 | 18 | 15.11 | 1875 | 510 | 2.74 / 71.91 | 2 | 3 |
5 | 13 | 582.40 | 18 | 15.24 | 1093 | 300 | 3.04 / 72.21 | 2 | 3 |
6 | 8 | 0.36 | 165 | 15.34 | 286 | 724 | 3.77 / 72.94 | 2 | 6 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 31 | 15.32 | 435 | 207 | 0.21 / 65.43 | 2 | 2 |
2 | 7 | 2007.84 | 31 | 15.02 | 2935 | 1367 | 1.57 / 66.79 | 2 | 3 |
3 | 13 | 1594.28 | 18 | 15.06 | 2420 | 656 | 2.23 / 67.45 | 2 | 3 |
4 | 13 | 1045.16 | 18 | 15.13 | 1717 | 468 | 2.70 / 67.92 | 2 | 3 |
5 | 13 | 470.00 | 18 | 15.29 | 950 | 261 | 2.96 / 68.18 | 2 | 3 |
6 | 13 | 25.72 | 18 | 15.37 | 343 | 95 | 3.05 / 68.27 | 2 | 3 |
7 | 8 | -0.12 | 165 | 15.34 | 293 | 742 | 3.79 / 69.02 | 2 | 9 |
8 | 14 | -0.12 | 35 | 15.33 | 290 | 156 | 3.95 / 69.17 | 3 | 8 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 31 | 15.31 | 443 | 210 | 0.21 / 61.77 | 2 | 2 |
2 | 7 | 2005.12 | 32 | 15.01 | 2927 | 1406 | 1.62 / 63.18 | 2 | 3 |
3 | 13 | 1579.32 | 18 | 15.05 | 2406 | 652 | 2.27 / 63.83 | 2 | 3 |
4 | 13 | 1022.76 | 18 | 15.15 | 1684 | 459 | 2.73 / 64.29 | 2 | 3 |
5 | 13 | 337.12 | 18 | 15.30 | 758 | 209 | 2.94 / 64.50 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.35 | 285 | 722 | 3.66 / 65.22 | 2 | 5 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 31 | 15.33 | 453 | 215 | 0.22 / 58.10 | 2 | 2 |
2 | 7 | 2003.32 | 33 | 15.00 | 2916 | 1443 | 1.66 / 59.54 | 2 | 2 |
3 | 13 | 1581.84 | 17 | 15.04 | 2404 | 615 | 2.27 / 60.16 | 2 | 3 |
4 | 13 | 1009.12 | 17 | 15.15 | 1673 | 431 | 2.70 / 60.59 | 2 | 3 |
5 | 13 | 436.72 | 17 | 15.29 | 896 | 233 | 2.94 / 60.82 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.36 | 293 | 743 | 3.68 / 61.56 | 2 | 4 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 31 | 15.30 | 447 | 212 | 0.21 / 54.44 | 2 | 2 |
2 | 7 | 2002.48 | 33 | 15.00 | 2913 | 1442 | 1.65 / 55.88 | 2 | 3 |
3 | 13 | 1457.84 | 17 | 15.07 | 2247 | 576 | 2.23 / 56.46 | 2 | 3 |
4 | 13 | 1042.36 | 17 | 15.15 | 1712 | 441 | 2.67 / 56.90 | 2 | 3 |
5 | 13 | 451.56 | 17 | 15.28 | 922 | 239 | 2.91 / 57.14 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.35 | 293 | 742 | 3.65 / 57.88 | 2 | 4 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 31 | 15.32 | 448 | 213 | 0.21 / 50.74 | 2 | 2 |
2 | 7 | 2004.36 | 34 | 15.00 | 2928 | 1493 | 1.71 / 52.23 | 2 | 2 |
3 | 13 | 1451.56 | 17 | 15.08 | 2236 | 573 | 2.28 / 52.80 | 2 | 3 |
4 | 13 | 1039.36 | 17 | 15.14 | 1704 | 439 | 2.72 / 53.24 | 2 | 3 |
5 | 13 | 460.84 | 17 | 15.28 | 934 | 243 | 2.96 / 53.49 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.36 | 294 | 745 | 3.71 / 54.23 | 2 | 6 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 30 | 15.32 | 445 | 205 | 0.20 / 46.97 | 2 | 2 |
2 | 3 | 1016.72 | 1 | 15.39 | 1729 | 27 | 0.23 / 46.99 | 2 | 3 |
3 | 7 | 2010.48 | 34 | 15.01 | 2925 | 1493 | 1.72 / 48.49 | 2 | 3 |
4 | 13 | 1579.60 | 17 | 15.05 | 2412 | 617 | 2.34 / 49.10 | 2 | 3 |
5 | 13 | 1010.00 | 17 | 15.15 | 1674 | 431 | 2.77 / 49.53 | 2 | 3 |
6 | 13 | 449.16 | 17 | 15.28 | 916 | 238 | 3.01 / 49.77 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.36 | 297 | 753 | 3.76 / 50.53 | 2 | 7 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 32 | 15.34 | 452 | 222 | 0.22 / 43.29 | 2 | 2 |
2 | 3 | 964.12 | -1 | 15.64 | 0 | 0 | 0.00 / 43.29 | 2 | 2 |
3 | 7 | 2008.00 | 30 | 15.03 | 2936 | 1324 | 1.55 / 44.61 | 2 | 3 |
4 | 13 | 1590.84 | 18 | 15.06 | 2428 | 658 | 2.20 / 45.27 | 2 | 3 |
5 | 13 | 1156.32 | 18 | 15.12 | 1852 | 504 | 2.71 / 45.78 | 2 | 3 |
6 | 13 | 428.56 | 18 | 15.30 | 889 | 245 | 2.95 / 46.02 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.36 | 293 | 743 | 3.70 / 46.76 | 2 | 5 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 31 | 15.31 | 443 | 210 | 0.21 / 39.54 | 2 | 2 |
2 | 7 | 2008.64 | 30 | 15.03 | 2922 | 1318 | 1.53 / 40.85 | 2 | 3 |
3 | 13 | 1733.08 | 18 | 15.04 | 2586 | 700 | 2.23 / 41.55 | 2 | 2 |
4 | 13 | 1135.96 | 18 | 15.12 | 1827 | 497 | 2.73 / 42.05 | 2 | 3 |
5 | 13 | 547.36 | 18 | 15.26 | 1046 | 287 | 3.01 / 42.34 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.36 | 288 | 730 | 3.74 / 43.07 | 2 | 4 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 31 | 15.34 | 452 | 215 | 0.21 / 35.90 | 2 | 2 |
2 | 7 | 2006.40 | 30 | 15.03 | 2928 | 1320 | 1.54 / 37.22 | 2 | 3 |
3 | 13 | 1593.32 | 18 | 15.05 | 2420 | 656 | 2.19 / 37.87 | 2 | 3 |
4 | 13 | 1047.84 | 18 | 15.15 | 1718 | 468 | 2.66 / 38.34 | 2 | 3 |
5 | 13 | 458.60 | 18 | 15.28 | 928 | 255 | 2.91 / 38.60 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.36 | 287 | 727 | 3.64 / 39.32 | 2 | 7 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.56 | 31 | 15.31 | 468 | 222 | 0.22 / 32.21 | 2 | 2 |
2 | 7 | 2009.60 | 30 | 15.05 | 2933 | 1324 | 1.55 / 33.53 | 2 | 3 |
3 | 13 | 1598.84 | 18 | 15.06 | 2443 | 662 | 2.21 / 34.19 | 2 | 3 |
4 | 13 | 1167.04 | 18 | 15.13 | 1876 | 511 | 2.72 / 34.70 | 2 | 3 |
5 | 13 | 432.84 | 18 | 15.29 | 888 | 244 | 2.96 / 34.95 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.37 | 290 | 735 | 3.70 / 35.68 | 2 | 6 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 31 | 15.34 | 449 | 214 | 0.21 / 28.48 | 2 | 2 |
2 | 7 | 2005.52 | 30 | 15.04 | 2920 | 1318 | 1.53 / 29.80 | 2 | 3 |
3 | 13 | 1596.68 | 18 | 15.07 | 2411 | 654 | 2.19 / 30.46 | 2 | 3 |
4 | 13 | 1153.08 | 18 | 15.13 | 1843 | 502 | 2.69 / 30.96 | 2 | 3 |
5 | 13 | 548.52 | 18 | 15.26 | 1048 | 288 | 2.97 / 31.25 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.36 | 291 | 738 | 3.71 / 31.98 | 2 | 4 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 31 | 15.33 | 443 | 211 | 0.21 / 24.84 | 2 | 2 |
2 | 7 | 2007.84 | 30 | 15.05 | 2917 | 1317 | 1.53 / 26.15 | 2 | 2 |
3 | 13 | 1598.84 | 18 | 15.08 | 2413 | 655 | 2.18 / 26.81 | 2 | 2 |
4 | 13 | 1156.92 | 18 | 15.13 | 1846 | 503 | 2.69 / 27.31 | 2 | 2 |
5 | 13 | 410.60 | 18 | 15.30 | 855 | 235 | 2.92 / 27.55 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.37 | 286 | 725 | 3.65 / 28.27 | 2 | 5 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 29 | 15.34 | 441 | 196 | 0.20 / 20.48 | 2 | 2 |
2 | 3 | 1057.96 | 2 | 15.34 | 1798 | 55 | 0.25 / 20.54 | 2 | 2 |
3 | 7 | 2008.76 | 74 | 14.88 | 2903 | 3197 | 3.45 / 23.73 | 2 | 2 |
4 | 13 | 230.64 | 18 | 15.36 | 609 | 168 | 3.62 / 23.90 | 2 | 2 |
5 | 8 | 0.16 | 165 | 15.38 | 285 | 723 | 4.34 / 24.63 | 2 | 5 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 26 | 15.34 | 444 | 177 | 0.18 / 16.09 | 2 | 2 |
2 | 10 | 1040.40 | 2 | 15.30 | 1728 | 53 | 0.23 / 16.15 | 2 | 2 |
3 | 3 | 1054.00 | 2 | 15.33 | 1791 | 55 | 0.28 / 16.20 | 2 | 2 |
4 | 7 | 2008.04 | 74 | 14.88 | 2903 | 3197 | 3.48 / 19.40 | 2 | 2 |
5 | 13 | 220.76 | 18 | 15.37 | 599 | 166 | 3.65 / 19.56 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.38 | 285 | 723 | 4.37 / 20.29 | 2 | 5 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 29 | 15.35 | 428 | 191 | 0.19 / 12.32 | 2 | 2 |
2 | 7 | 1521.52 | 74 | 15.06 | 2287 | 2549 | 2.74 / 14.87 | 2 | 3 |
3 | 8 | 0.12 | 165 | 15.39 | 284 | 721 | 3.46 / 15.59 | 2 | 4 |
4 | 14 | 0.12 | 75 | 15.35 | 281 | 324 | 3.78 / 15.92 | 2 | 12 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 29 | 15.34 | 440 | 196 | 0.20 / 8.86 | 2 | 2 |
2 | 3 | 1019.20 | 1 | 15.42 | 1729 | 27 | 0.22 / 8.88 | 2 | 2 |
3 | 7 | 1508.84 | 74 | 15.05 | 2264 | 2521 | 2.74 / 11.41 | 2 | 2 |
4 | 8 | 0.08 | 165 | 15.39 | 286 | 726 | 3.47 / 12.13 | 2 | 9 |
Average= | 3.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 28 | 15.31 | 446 | 191 | 0.19 / 5.11 | 2 | 2 |
2 | 3 | 1049.76 | 1 | 15.32 | 1762 | 27 | 0.22 / 5.13 | 2 | 2 |
3 | 7 | 1448.92 | 75 | 15.06 | 2192 | 2476 | 2.69 / 7.61 | 2 | 2 |
4 | 8 | 0.12 | 165 | 15.38 | 286 | 726 | 3.42 / 8.34 | 2 | 6 |
5 | 14 | 0.12 | 75 | 15.36 | 283 | 326 | 3.75 / 8.66 | 2 | 9 |
Average= | 2.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 24 | 15.49 | 446 | 166 | 0.17 / 1.93 | 2 | 2 |
2 | 10 | 1022.04 | 4 | 15.28 | 1703 | 104 | 0.27 / 2.04 | 2 | 2 |
3 | 3 | 1048.40 | 1 | 15.31 | 1782 | 27 | 0.30 / 2.07 | 2 | 2 |
4 | 7 | 1001.24 | 74 | 15.17 | 1608 | 1805 | 2.10 / 3.87 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.36 | 284 | 720 | 2.82 / 4.59 | 2 | 6 |
6 | 14 | 0.20 | 75 | 15.33 | 282 | 324 | 3.15 / 4.92 | 2 | 15 |
Average= | 2.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.36 | 24 | 15.62 | 465 | 174 | 0.17 / 0.17 | 2 | 3 |
2 | 7 | 132.04 | 74 | 15.57 | 474 | 546 | 0.72 / 0.72 | 2 | 4 |
3 | 8 | 0.08 | 240 | 15.55 | 281 | 1049 | 1.77 / 1.77 | 2 | 14 |
Average= | 1.77 (KJ/cycle) |