SIO Argo Site:
Pump Diagnostics Page   



Serial= 8878 WMO= 1902258

Return

←PreviousNext→

Cycle 163 GMT 20/12/2024 16:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 32 14.95 445 213 0.21 / 616.58 2 3
2 7 2006.04 32 14.85 2863 1360 1.57 / 617.94 2 3
3 13 1757.44 19 14.84 2543 717 2.29 / 618.66 2 3
4 13 1194.60 19 14.78 1976 555 2.85 / 619.21 2 4
5 13 632.72 19 14.89 1204 341 3.19 / 619.55 2 4
6 13 77.32 19 14.99 434 124 3.31 / 619.68 2 3
7 8 0.04 165 14.96 325 802 4.11 / 620.48 2 4
Average= 3.78
(KJ/cycle)

Cycle 162 GMT 10/12/2024 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 32 14.95 432 207 0.21 / 612.69 3 3
2 7 2008.48 33 14.83 2896 1417 1.62 / 614.11 2 4
3 13 1602.72 19 14.80 2434 684 2.31 / 614.79 2 3
4 13 1166.12 19 14.82 1885 531 2.84 / 615.32 2 4
5 13 440.96 19 14.94 895 254 3.09 / 615.58 2 3
6 13 29.76 19 15.01 361 103 3.20 / 615.68 2 3
7 8 0.12 165 14.99 278 688 3.88 / 616.37 2 4
Average= 3.78
(KJ/cycle)

Cycle 161 GMT 1/12/2024 2:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 32 14.95 435 208 0.21 / 608.73 3 3
2 7 2011.24 32 14.88 2775 1321 1.53 / 610.05 2 3
3 13 1734.80 19 14.82 2558 720 2.25 / 610.77 2 3
4 13 1278.08 19 14.82 2006 565 2.81 / 611.33 2 3
5 13 660.52 19 14.89 1218 345 3.16 / 611.68 2 3
6 13 79.80 19 15.01 402 115 3.27 / 611.79 2 3
7 8 -0.16 165 14.99 280 693 3.97 / 612.48 2 6
Average= 3.78
(KJ/cycle)

Cycle 160 GMT 21/11/2024 7:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 32 14.97 432 207 0.21 / 604.62 2 3
2 7 2010.12 32 14.86 3018 1435 1.64 / 606.06 2 3
3 13 1756.24 19 14.90 2525 715 2.36 / 606.77 2 3
4 13 1223.24 19 14.79 1989 559 2.92 / 607.33 2 3
5 13 806.04 19 14.86 1403 396 3.31 / 607.73 2 4
6 13 103.84 19 15.01 418 119 3.43 / 607.85 2 3
7 8 -0.12 165 14.99 271 670 4.10 / 608.52 2 8
Average= 3.78
(KJ/cycle)

Cycle 159 GMT 11/11/2024 12: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 32 14.96 440 211 0.21 / 600.94 2 3
2 7 2007.60 32 14.82 2894 1372 1.58 / 602.32 2 3
3 13 1609.08 19 14.82 2438 686 2.27 / 603.00 2 3
4 13 1050.52 19 14.84 1739 490 2.76 / 603.49 2 3
5 13 357.12 19 14.97 792 225 2.99 / 603.72 2 3
6 8 0.08 165 15.01 282 698 3.68 / 604.42 2 5
Average= 3.78
(KJ/cycle)

Cycle 158 GMT 1/11/2024 16:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 32 14.96 445 213 0.21 / 596.96 2 3
2 7 2008.04 32 14.91 2802 1337 1.55 / 598.29 2 3
3 13 1766.48 19 14.84 2539 716 2.27 / 599.01 2 3
4 13 1243.96 19 14.83 1901 536 2.80 / 599.55 2 3
5 13 828.88 19 14.86 1400 395 3.20 / 599.94 2 3
6 13 105.12 19 15.02 422 120 3.32 / 600.06 2 3
7 8 0.12 165 15.00 271 671 3.99 / 600.73 2 7
Average= 3.78
(KJ/cycle)

Cycle 157 GMT 22/10/2024 21:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 32 14.96 461 221 0.22 / 593.18 2 3
2 7 2004.44 32 14.86 2847 1354 1.57 / 594.53 2 3
3 13 1604.72 19 14.83 2430 685 2.26 / 595.22 2 3
4 13 1057.24 19 14.87 1730 489 2.75 / 595.71 2 3
5 13 461.88 19 14.95 931 264 3.01 / 595.97 2 3
6 13 24.20 19 15.04 310 89 3.10 / 596.06 2 3
7 8 -0.16 165 15.00 277 686 3.79 / 596.74 2 7
Average= 3.78
(KJ/cycle)

Cycle 156 GMT 13/10/2024 2:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 32 14.96 440 211 0.21 / 589.41 2 3
2 7 2007.60 32 14.84 2884 1370 1.58 / 590.78 2 3
3 13 1590.96 19 14.82 2435 686 2.27 / 591.46 2 3
4 13 1035.56 19 14.86 1739 491 2.76 / 591.95 2 3
5 13 449.92 19 14.94 936 266 3.02 / 592.22 2 3
6 8 0.16 165 15.00 298 738 3.76 / 592.96 2 7
Average= 3.78
(KJ/cycle)

Cycle 155 GMT 3/10/2024 7:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 32 14.96 461 221 0.22 / 585.31 2 3
2 7 2004.88 33 14.82 2844 1391 1.61 / 586.70 2 3
3 13 1761.04 19 14.88 2429 687 2.30 / 587.38 2 3
4 13 1348.96 19 14.74 2075 581 2.88 / 587.97 2 3
5 13 805.00 19 14.83 1423 401 3.28 / 588.37 2 3
6 13 113.96 19 15.02 448 128 3.41 / 588.49 2 3
7 8 0.08 165 15.01 284 703 4.11 / 589.20 2 7
Average= 3.78
(KJ/cycle)

Cycle 154 GMT 23/ 9/2024 11:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 32 14.96 453 217 0.22 / 581.62 2 3
2 7 2014.20 32 14.83 2906 1379 1.60 / 583.00 2 3
3 13 1593.32 19 14.80 2429 683 2.28 / 583.68 2 3
4 13 1041.68 19 14.83 1728 487 2.77 / 584.17 2 4
5 13 333.04 19 14.96 756 215 2.98 / 584.38 2 3
6 8 0.00 165 15.00 285 705 3.69 / 585.09 2 6
Average= 3.77
(KJ/cycle)

Cycle 153 GMT 13/ 9/2024 16:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 32 14.95 447 214 0.21 / 577.88 2 3
2 7 2004.52 32 14.85 2843 1351 1.56 / 579.24 2 3
3 13 1608.76 19 14.82 2433 685 2.25 / 579.92 2 3
4 13 1047.80 19 14.84 1745 492 2.74 / 580.41 2 3
5 13 463.92 19 14.95 924 262 3.00 / 580.68 2 4
6 8 -0.04 165 15.00 293 725 3.73 / 581.40 2 11
Average= 3.78
(KJ/cycle)

Cycle 152 GMT 3/ 9/2024 21:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 32 14.95 431 206 0.21 / 574.16 2 3
2 7 2008.24 32 14.83 2883 1368 1.57 / 575.53 2 3
3 13 1615.72 19 14.81 2450 689 2.26 / 576.22 2 3
4 13 1044.24 19 14.84 1725 486 2.75 / 576.71 2 3
5 13 470.80 19 14.93 937 266 3.02 / 576.97 2 3
6 8 0.32 165 15.00 282 698 3.71 / 577.67 2 6
Average= 3.78
(KJ/cycle)

Cycle 151 GMT 25/ 8/2024 2:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 32 14.95 444 212 0.21 / 570.21 2 3
2 7 2005.24 33 14.88 2778 1364 1.58 / 571.57 2 3
3 13 1737.52 19 14.85 2464 695 2.27 / 572.26 2 3
4 13 1196.16 19 14.82 1857 523 2.79 / 572.79 2 3
5 13 771.72 19 14.86 1320 373 3.17 / 573.16 2 4
6 13 80.48 19 15.03 388 111 3.28 / 573.27 2 3
7 8 0.00 165 15.00 277 686 3.96 / 573.96 2 7
Average= 3.78
(KJ/cycle)

Cycle 150 GMT 15/ 8/2024 7: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 32 14.96 448 214 0.21 / 566.03 2 3
2 7 2007.20 32 14.85 2806 1333 1.55 / 567.36 2 3
3 13 1753.24 19 14.77 2699 757 2.31 / 568.12 2 3
4 13 1341.76 19 14.82 1941 547 2.85 / 568.67 2 3
5 13 933.64 19 14.80 1590 447 3.30 / 569.11 2 4
6 13 203.32 19 14.99 565 161 3.46 / 569.28 2 3
7 8 0.16 165 15.00 290 718 4.18 / 569.99 2 4
Average= 3.77
(KJ/cycle)

Cycle 149 GMT 5/ 8/2024 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 32 14.95 443 212 0.21 / 562.16 2 3
2 7 2004.72 33 14.84 2810 1376 1.59 / 563.53 2 3
3 13 1717.04 19 14.81 2527 711 2.30 / 564.25 2 3
4 13 1251.56 19 14.82 2009 566 2.86 / 564.81 2 3
5 13 481.60 19 14.95 946 269 3.13 / 565.08 2 3
6 8 0.28 165 15.01 297 736 3.87 / 565.82 2 4
Average= 3.77
(KJ/cycle)

Cycle 148 GMT 26/ 7/2024 17: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 32 14.96 442 212 0.21 / 558.13 2 3
2 7 2010.08 32 14.82 2849 1351 1.56 / 559.48 2 3
3 13 1881.44 19 14.81 2639 743 2.31 / 560.22 2 3
4 13 1191.28 19 14.85 1812 511 2.82 / 560.73 2 3
5 13 782.56 19 14.86 1403 396 3.21 / 561.13 2 4
6 13 77.96 19 15.03 397 113 3.33 / 561.24 2 3
7 8 -0.04 165 15.00 285 705 4.03 / 561.95 2 4
Average= 3.77
(KJ/cycle)

Cycle 147 GMT 16/ 7/2024 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 32 14.98 453 217 0.22 / 554.35 3 3
2 7 2011.48 32 14.84 2843 1350 1.57 / 555.70 2 3
3 13 1608.56 19 14.82 2407 678 2.24 / 556.38 2 3
4 13 1053.12 19 14.85 1709 482 2.73 / 556.86 2 4
5 13 473.40 19 14.95 923 262 2.99 / 557.12 2 3
6 13 14.68 19 15.03 302 86 3.08 / 557.21 2 3
7 8 0.16 165 15.00 285 705 3.78 / 557.91 2 5
Average= 3.77
(KJ/cycle)

Cycle 146 GMT 7/ 7/2024 2:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 32 14.97 449 215 0.22 / 550.53 3 3
2 7 2007.96 33 14.86 2843 1394 1.61 / 551.92 2 3
3 13 1599.04 19 14.83 2409 679 2.29 / 552.60 2 3
4 13 1035.24 19 14.87 1691 478 2.77 / 553.08 2 4
5 13 450.60 19 14.97 893 254 3.02 / 553.33 2 3
6 13 29.72 19 15.04 322 92 3.11 / 553.43 2 2
7 8 0.08 165 15.01 286 708 3.82 / 554.13 2 6
Average= 3.77
(KJ/cycle)

Cycle 145 GMT 27/ 6/2024 7:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 32 14.97 448 215 0.21 / 546.44 3 3
2 3 1016.16 1 15.28 1362 21 0.24 / 546.46 2 3
3 7 2008.24 32 14.88 2772 1320 1.56 / 547.78 2 3
4 13 1882.76 19 14.76 2767 776 2.33 / 548.56 2 5
5 13 1301.36 19 14.86 1952 551 2.88 / 549.11 2 3
6 13 726.68 19 14.92 1275 361 3.24 / 549.47 2 4
7 13 122.40 19 15.03 442 126 3.37 / 549.60 2 3
8 8 0.28 165 15.02 290 719 4.09 / 550.31 2 6
Average= 3.77
(KJ/cycle)

Cycle 144 GMT 17/ 6/2024 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 32 14.97 433 207 0.21 / 542.55 2 3
2 7 2012.72 32 14.85 2900 1378 1.59 / 543.93 2 3
3 13 1615.28 19 14.84 2455 692 2.28 / 544.62 2 3
4 13 1167.28 19 14.84 1882 531 2.81 / 545.15 2 3
5 13 414.16 19 14.98 873 248 3.06 / 545.40 2 3
6 13 23.16 19 15.05 333 95 3.15 / 545.50 2 2
7 8 -0.24 165 15.01 294 728 3.88 / 546.23 2 5
Average= 3.77
(KJ/cycle)

Cycle 143 GMT 7/ 6/2024 17: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.32 32 14.96 480 230 0.23 / 538.59 2 3
2 7 2012.20 32 14.81 2946 1396 1.63 / 539.99 2 2
3 13 1748.00 19 14.86 2481 700 2.33 / 540.69 2 3
4 13 1175.08 19 14.78 1910 536 2.86 / 541.22 2 3
5 13 606.76 19 14.91 1137 322 3.18 / 541.55 2 3
6 13 67.20 19 15.03 372 106 3.29 / 541.65 2 2
7 8 0.12 165 15.01 280 693 3.98 / 542.34 2 4
Average= 3.77
(KJ/cycle)

Cycle 142 GMT 28/ 5/2024 22: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 32 14.97 454 217 0.22 / 534.75 2 3
2 7 2007.72 32 14.87 2835 1349 1.57 / 536.10 2 3
3 13 1601.36 19 14.84 2394 675 2.24 / 536.77 2 3
4 13 1057.92 19 14.87 1720 486 2.73 / 537.26 2 3
5 13 481.64 19 14.96 944 268 3.00 / 537.53 2 4
6 13 37.88 19 15.04 349 100 3.10 / 537.63 2 3
7 8 0.12 165 15.01 296 733 3.83 / 538.36 2 6
Average= 3.76
(KJ/cycle)

Cycle 141 GMT 19/ 5/2024 2:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 32 14.96 455 218 0.22 / 530.95 3 3
2 7 2010.00 33 14.85 2828 1386 1.60 / 532.33 2 4
3 13 1607.80 19 14.84 2388 673 2.28 / 533.01 2 4
4 13 1047.92 19 14.85 1720 485 2.76 / 533.49 2 3
5 13 343.84 19 14.99 780 222 2.98 / 533.71 2 3
6 13 20.08 19 15.03 331 95 3.08 / 533.81 2 3
7 8 0.08 165 15.00 292 723 3.80 / 534.53 2 5
Average= 3.76
(KJ/cycle)

Cycle 140 GMT 9/ 5/2024 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 32 14.95 437 209 0.21 / 527.16 2 3
2 7 2010.20 33 14.85 2884 1413 1.62 / 528.57 2 3
3 13 1499.28 19 14.84 2307 650 2.27 / 529.22 2 3
4 13 948.56 19 14.88 1601 453 2.73 / 529.68 2 3
5 13 392.84 19 14.97 844 240 2.97 / 529.92 2 3
6 13 23.32 19 15.04 329 94 3.06 / 530.01 2 3
7 8 0.08 165 15.01 291 721 3.78 / 530.73 2 4
Average= 3.76
(KJ/cycle)

Cycle 139 GMT 29/ 4/2024 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 32 14.96 463 222 0.22 / 523.13 3 3
2 7 2005.20 32 14.86 2892 1375 1.60 / 524.51 2 4
3 13 1607.88 19 14.87 2389 675 2.27 / 525.18 2 3
4 13 1190.20 19 14.79 1972 554 2.83 / 525.74 2 3
5 13 752.56 19 14.90 1313 372 3.20 / 526.11 2 4
6 13 57.76 19 15.03 376 107 3.31 / 526.22 2 3
7 8 0.12 165 14.99 297 735 4.04 / 526.95 2 3
Average= 3.76
(KJ/cycle)

Cycle 138 GMT 19/ 4/2024 17: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 32 14.95 437 209 0.21 / 519.22 3 3
2 7 2006.48 32 14.85 2895 1376 1.58 / 520.60 2 3
3 13 1750.32 19 14.79 2617 735 2.32 / 521.33 2 3
4 13 1127.44 19 14.85 1801 508 2.83 / 521.84 2 3
5 13 406.72 19 14.97 851 242 3.07 / 522.08 2 3
6 13 49.68 19 15.03 359 103 3.17 / 522.19 2 3
7 8 0.08 165 15.00 292 723 3.90 / 522.91 2 6
Average= 3.76
(KJ/cycle)

Cycle 137 GMT 9/ 4/2024 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 32 14.94 434 207 0.21 / 515.45 2 3
2 7 2003.84 33 14.85 2867 1405 1.61 / 516.85 2 3
3 13 1581.40 19 14.83 2400 676 2.29 / 517.53 2 3
4 13 1016.72 19 14.87 1677 474 2.76 / 518.00 2 3
5 13 308.36 19 14.99 713 203 2.97 / 518.20 2 3
6 13 31.48 19 15.03 334 95 3.06 / 518.30 2 3
7 8 -0.24 165 15.01 289 716 3.78 / 519.01 2 7
Average= 3.76
(KJ/cycle)

Cycle 136 GMT 31/ 3/2024 2: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 32 14.94 451 216 0.22 / 511.66 3 3
2 7 2005.64 32 14.85 2819 1340 1.56 / 513.00 2 3
3 13 1597.04 19 14.77 2419 679 2.23 / 513.68 2 3
4 13 1031.32 19 14.83 1700 479 2.71 / 514.16 2 3
5 13 445.20 19 14.94 921 261 2.97 / 514.42 2 4
6 13 29.52 19 15.01 334 95 3.07 / 514.51 2 3
7 8 0.04 165 14.98 293 724 3.79 / 515.24 2 6
Average= 3.76
(KJ/cycle)

Cycle 135 GMT 21/ 3/2024 7: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 32 14.93 440 210 0.21 / 507.82 2 3
2 7 2002.72 32 14.85 2875 1366 1.58 / 509.18 2 3
3 13 1584.40 19 14.82 2445 688 2.26 / 509.87 2 4
4 13 1130.56 19 14.87 1791 506 2.77 / 510.38 2 3
5 13 389.12 19 14.95 843 239 3.01 / 510.62 2 3
6 13 52.16 19 15.00 364 104 3.11 / 510.72 2 3
7 8 0.00 165 14.99 293 725 3.84 / 511.44 2 3
Average= 3.76
(KJ/cycle)

Cycle 134 GMT 11/ 3/2024 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 32 14.94 460 220 0.22 / 504.02 3 3
2 3 1016.28 1 15.19 1526 23 0.24 / 504.04 2 3
3 7 2011.68 33 14.85 2828 1386 1.63 / 505.43 2 3
4 13 1605.04 19 14.84 2357 665 2.29 / 506.09 2 3
5 13 1041.40 19 14.85 1713 483 2.78 / 506.58 2 3
6 13 335.44 19 14.97 733 208 2.99 / 506.78 2 3
7 13 44.68 19 15.02 337 96 3.08 / 506.88 2 3
8 8 0.04 165 14.99 293 725 3.81 / 507.61 2 7
Average= 3.76
(KJ/cycle)

Cycle 133 GMT 1/ 3/2024 16: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 32 14.94 435 208 0.21 / 500.04 3 3
2 7 2005.04 32 14.85 2859 1359 1.57 / 501.40 2 3
3 13 1581.04 19 14.82 2392 674 2.24 / 502.07 2 3
4 13 1139.20 19 14.85 1826 515 2.76 / 502.58 2 4
5 13 390.64 19 14.96 842 239 2.99 / 502.82 2 3
6 13 52.36 19 15.02 373 106 3.10 / 502.93 2 3
7 8 0.00 165 14.99 297 735 3.84 / 503.66 2 7
8 14 0.00 30 14.97 299 134 3.97 / 503.80 3 11
Average= 3.76
(KJ/cycle)

Cycle 132 GMT 20/ 2/2024 20:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 32 14.97 440 211 0.21 / 496.32 3 3
2 7 2011.48 32 14.84 2859 1358 1.57 / 497.68 2 3
3 13 1482.16 19 14.82 2267 638 2.21 / 498.32 2 3
4 13 1063.16 19 14.85 1732 489 2.70 / 498.81 2 3
5 13 228.56 19 15.01 600 171 2.87 / 498.98 2 3
6 13 43.04 19 15.03 354 101 2.97 / 499.08 2 3
7 8 -0.16 165 14.99 303 749 3.72 / 499.83 2 6
Average= 3.76
(KJ/cycle)

Cycle 131 GMT 11/ 2/2024 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 32 14.96 442 212 0.21 / 492.58 2 3
2 7 2004.40 33 14.85 2863 1403 1.61 / 493.99 2 3
3 13 1483.56 19 14.84 2274 641 2.26 / 494.63 2 3
4 13 1067.72 19 14.86 1738 491 2.75 / 495.12 2 3
5 13 222.84 19 15.01 592 169 2.92 / 495.29 2 3
6 13 42.88 19 15.04 351 100 3.02 / 495.39 2 3
7 8 0.08 165 15.01 293 726 3.74 / 496.11 2 7
Average= 3.76
(KJ/cycle)

Cycle 130 GMT 1/ 2/2024 5:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 32 14.97 465 223 0.22 / 488.82 3 3
2 7 2010.92 32 14.87 2817 1340 1.56 / 490.16 2 4
3 13 1601.08 19 14.84 2360 665 2.23 / 490.82 2 3
4 13 1039.64 19 14.87 1685 476 2.70 / 491.30 2 4
5 13 460.52 19 14.96 896 255 2.96 / 491.55 2 3
6 13 33.16 19 15.04 323 92 3.05 / 491.65 2 3
7 8 0.16 165 15.01 292 723 3.77 / 492.37 2 6
Average= 3.76
(KJ/cycle)

Cycle 129 GMT 22/ 1/2024 7:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 32 14.97 462 221 0.22 / 484.98 2 3
2 7 2005.56 32 14.87 2867 1364 1.59 / 486.35 2 3
3 13 1609.72 19 14.84 2426 684 2.27 / 487.03 2 3
4 13 1044.08 19 14.87 1733 490 2.76 / 487.52 2 3
5 13 460.52 19 14.95 941 267 3.03 / 487.79 2 3
6 13 30.84 19 15.04 334 95 3.12 / 487.88 2 2
7 8 0.04 165 15.01 288 713 3.84 / 488.60 2 5
Average= 3.76
(KJ/cycle)

Cycle 128 GMT 12/ 1/2024 9:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 32 14.95 498 238 0.24 / 481.13 3 3
2 7 2007.08 33 14.85 2900 1421 1.66 / 482.56 2 3
3 13 1602.24 19 14.84 2449 691 2.35 / 483.25 2 3
4 13 1037.60 19 14.87 1710 483 2.83 / 483.73 2 3
5 13 324.16 19 14.99 746 212 3.05 / 483.94 2 3
6 13 31.76 19 15.04 327 93 3.14 / 484.03 2 3
7 8 0.12 165 15.01 293 726 3.86 / 484.76 2 11
Average= 3.76
(KJ/cycle)

Cycle 127 GMT 2/ 1/2024 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 32 14.96 498 238 0.24 / 477.14 2 3
2 7 2007.56 32 14.82 2896 1373 1.61 / 478.51 2 3
3 13 1587.44 19 14.81 2460 692 2.30 / 479.20 2 3
4 13 1008.36 19 14.85 1726 487 2.79 / 479.69 2 3
5 13 431.88 19 14.95 953 271 3.06 / 479.96 2 3
6 13 26.28 19 15.03 373 107 3.17 / 480.07 2 2
7 8 0.08 165 14.99 335 829 4.00 / 480.90 2 3
Average= 3.76
(KJ/cycle)

Cycle 126 GMT 23/12/2023 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 32 14.95 498 238 0.24 / 473.15 3 3
2 7 2008.04 32 14.86 2896 1377 1.62 / 474.52 2 3
3 13 1594.36 19 14.83 2430 685 2.30 / 475.21 2 3
4 13 1158.92 19 14.85 1894 534 2.83 / 475.74 2 3
5 13 419.00 19 14.98 902 257 3.09 / 476.00 2 4
6 13 27.88 19 15.05 366 105 3.20 / 476.10 2 3
7 8 0.16 165 15.01 321 795 3.99 / 476.90 2 4
Average= 3.76
(KJ/cycle)

Cycle 125 GMT 13/12/2023 16:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 32 14.96 487 233 0.23 / 469.12 2 3
2 7 2003.76 32 14.87 2877 1369 1.60 / 470.49 2 2
3 13 1720.64 19 14.83 2588 729 2.33 / 471.21 2 3
4 13 1127.28 19 14.86 1840 520 2.85 / 471.73 2 3
5 13 519.08 19 14.95 1029 292 3.14 / 472.03 2 3
6 13 38.60 19 15.04 363 104 3.25 / 472.13 2 4
7 8 0.12 165 15.01 314 778 4.02 / 472.91 2 5
Average= 3.75
(KJ/cycle)

Cycle 124 GMT 3/12/2023 19: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 32 14.96 470 225 0.22 / 465.20 2 3
2 7 2010.40 32 14.87 2889 1375 1.60 / 466.58 2 3
3 13 1610.92 19 14.83 2443 688 2.29 / 467.26 2 4
4 13 1048.28 19 14.86 1733 489 2.78 / 467.75 2 3
5 13 474.44 19 14.96 963 274 3.05 / 468.03 2 3
6 13 27.76 19 15.04 349 100 3.15 / 468.13 2 3
7 8 -0.08 165 15.00 306 757 3.91 / 468.88 2 10
Average= 3.75
(KJ/cycle)

Cycle 123 GMT 23/11/2023 21: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 32 15.00 439 211 0.21 / 461.12 2 3
2 7 2004.32 33 14.86 2871 1408 1.62 / 462.53 2 3
3 13 1585.52 19 14.85 2406 679 2.30 / 463.21 2 3
4 13 1024.00 19 14.87 1714 484 2.78 / 463.70 2 3
5 13 426.92 19 14.98 912 260 3.04 / 463.96 2 3
6 13 24.56 19 15.04 348 99 3.14 / 464.05 2 2
7 8 0.12 165 15.01 316 783 3.92 / 464.84 2 10
8 14 0.12 30 14.98 307 138 4.06 / 464.98 3 11
Average= 3.75
(KJ/cycle)

Cycle 122 GMT 13/11/2023 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 32 14.99 438 210 0.21 / 457.26 2 3
2 7 2009.36 32 14.85 2874 1366 1.58 / 458.63 2 4
3 13 1736.24 19 14.81 2575 725 2.30 / 459.35 2 3
4 13 1134.64 19 14.87 1820 514 2.81 / 459.87 2 3
5 13 530.96 19 14.95 1003 285 3.10 / 460.15 2 3
6 13 39.80 19 15.06 310 89 3.19 / 460.24 2 3
7 8 -0.08 165 15.03 271 672 3.86 / 460.91 2 6
Average= 3.75
(KJ/cycle)

Cycle 121 GMT 4/11/2023 1:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 32 14.98 432 207 0.21 / 453.53 2 3
2 7 2003.36 33 14.86 2855 1400 1.61 / 454.93 2 3
3 13 1600.72 19 14.85 2398 677 2.28 / 455.61 2 4
4 13 1158.56 19 14.86 1851 523 2.81 / 456.13 2 3
5 13 406.92 19 15.00 830 237 3.04 / 456.37 2 3
6 8 0.00 165 15.04 276 685 3.73 / 457.05 2 5
Average= 3.75
(KJ/cycle)

Cycle 120 GMT 25/10/2023 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 32 15.00 433 208 0.21 / 449.69 2 3
2 7 2006.40 32 14.89 2828 1347 1.56 / 451.04 2 4
3 13 1590.00 19 14.85 2426 684 2.24 / 451.72 2 3
4 13 1152.72 19 14.86 1863 526 2.77 / 452.25 2 3
5 13 552.48 19 14.96 1055 300 3.07 / 452.55 2 3
6 13 18.08 19 15.06 312 89 3.15 / 452.64 2 3
7 8 0.08 165 15.02 277 686 3.84 / 453.33 2 4
Average= 3.75
(KJ/cycle)

Cycle 119 GMT 15/10/2023 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 32 15.00 440 211 0.21 / 445.96 3 3
2 7 2006.16 32 14.86 2865 1362 1.57 / 447.33 2 3
3 13 1588.48 19 14.85 2395 676 2.25 / 448.00 2 3
4 13 1023.84 19 14.89 1678 475 2.72 / 448.48 2 3
5 13 449.56 19 14.98 883 251 2.98 / 448.73 2 3
6 13 26.28 19 15.06 310 89 3.06 / 448.82 2 3
7 8 -0.20 165 15.03 269 667 3.73 / 449.48 2 4
Average= 3.75
(KJ/cycle)

Cycle 118 GMT 5/10/2023 8:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 32 14.99 435 209 0.21 / 442.23 2 3
2 7 2004.40 32 14.87 2860 1361 1.57 / 443.59 2 4
3 13 1584.44 19 14.84 2419 682 2.25 / 444.28 2 4
4 13 1151.20 19 14.86 1886 532 2.78 / 444.81 2 3
5 13 410.88 19 14.99 879 250 3.03 / 445.06 2 3
6 8 0.12 165 15.03 280 694 3.73 / 445.75 2 7
Average= 3.75
(KJ/cycle)

Cycle 117 GMT 25/ 9/2023 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 32 14.99 433 208 0.21 / 438.52 2 3
2 7 2007.28 32 14.87 2860 1361 1.57 / 439.88 2 2
3 13 1607.12 19 14.85 2420 683 2.25 / 440.56 2 4
4 13 1047.44 19 14.88 1719 486 2.74 / 441.05 2 4
5 13 356.88 19 15.00 772 220 2.96 / 441.27 2 3
6 13 38.04 19 15.06 334 96 3.05 / 441.36 2 2
7 8 0.08 165 15.03 267 662 3.72 / 442.02 2 9
Average= 3.75
(KJ/cycle)

Cycle 116 GMT 15/ 9/2023 12:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 32 14.99 431 207 0.21 / 434.69 2 3
2 7 2006.84 33 14.86 2857 1401 1.61 / 436.09 2 3
3 13 1591.24 19 14.85 2408 679 2.29 / 436.77 2 3
4 13 1008.80 19 14.88 1649 466 2.75 / 437.23 2 3
5 13 305.52 19 15.01 683 195 2.95 / 437.43 2 3
6 13 30.56 19 15.06 318 91 3.04 / 437.52 2 3
7 8 0.08 165 15.04 270 670 3.71 / 438.19 2 6
8 14 0.08 30 15.02 267 120 3.83 / 438.31 2 8
Average= 3.75
(KJ/cycle)

Cycle 115 GMT 5/ 9/2023 14:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 32 14.99 413 198 0.20 / 430.98 2 3
2 7 2003.68 32 14.86 2860 1360 1.56 / 432.34 2 3
3 13 1595.68 19 14.86 2416 682 2.24 / 433.02 2 4
4 13 1023.04 19 14.89 1708 483 2.72 / 433.50 2 3
5 13 318.88 19 15.02 728 208 2.93 / 433.71 2 3
6 13 31.32 19 15.07 327 94 3.02 / 433.81 2 3
7 8 -0.04 165 15.03 272 675 3.70 / 434.48 2 6
Average= 3.75
(KJ/cycle)

Cycle 114 GMT 26/ 8/2023 16:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 15.00 410 197 0.20 / 427.24 3 3
2 7 2012.40 32 14.86 2866 1363 1.56 / 428.60 2 4
3 13 1608.48 19 14.85 2413 681 2.24 / 429.28 2 3
4 13 1029.36 19 14.89 1681 476 2.72 / 429.76 2 3
5 13 441.24 19 14.98 882 251 2.97 / 430.01 2 3
6 13 53.16 19 15.04 354 101 3.07 / 430.11 2 3
7 8 0.04 165 15.03 270 670 3.74 / 430.78 2 5
Average= 3.75
(KJ/cycle)

Cycle 113 GMT 16/ 8/2023 18:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 32 15.00 441 212 0.21 / 423.45 2 3
2 7 2005.76 32 14.86 2875 1367 1.58 / 424.82 2 3
3 13 1480.48 19 14.86 2258 638 2.22 / 425.46 2 3
4 13 1066.28 19 14.89 1730 489 2.71 / 425.94 2 3
5 13 364.08 19 15.00 766 218 2.92 / 426.16 2 3
6 13 47.36 19 15.07 333 95 3.02 / 426.26 2 2
7 8 0.04 165 15.04 268 665 3.68 / 426.92 2 3
8 14 0.04 30 15.02 265 119 3.80 / 427.04 4 8
Average= 3.75
(KJ/cycle)

Cycle 112 GMT 6/ 8/2023 20:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 32 14.99 427 205 0.20 / 419.71 3 3
2 7 2009.88 32 14.88 2820 1343 1.55 / 421.06 2 3
3 13 1606.56 19 14.86 2385 673 2.22 / 421.73 2 3
4 13 1038.88 19 14.89 1693 479 2.70 / 422.21 2 3
5 13 460.40 19 14.98 910 259 2.96 / 422.47 2 3
6 13 63.32 19 15.06 358 102 3.06 / 422.57 2 3
7 8 -0.04 165 15.03 270 670 3.73 / 423.24 2 7
Average= 3.75
(KJ/cycle)

Cycle 111 GMT 27/ 7/2023 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 32 15.00 441 212 0.21 / 415.75 3 3
2 7 2009.24 32 14.89 2882 1373 1.58 / 417.12 2 3
3 13 1585.28 19 14.85 2419 683 2.27 / 417.80 2 3
4 13 1156.12 19 14.87 1866 527 2.79 / 418.33 2 3
5 13 558.28 19 14.96 1039 295 3.09 / 418.63 2 3
6 13 21.96 19 15.07 315 90 3.18 / 418.72 2 3
7 8 -0.16 165 15.04 270 670 3.85 / 419.39 2 6
8 14 -0.16 30 15.01 269 121 3.97 / 419.51 3 5
Average= 3.75
(KJ/cycle)

Cycle 110 GMT 18/ 7/2023 1:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 32 15.00 452 217 0.22 / 412.10 2 3
2 7 2010.24 32 14.90 2844 1356 1.57 / 413.46 2 3
3 13 1468.20 19 14.87 2271 642 2.21 / 414.10 2 3
4 13 1056.00 19 14.89 1752 496 2.71 / 414.60 2 4
5 13 462.64 19 14.98 936 266 2.98 / 414.86 2 3
6 8 -0.04 165 15.05 271 673 3.65 / 415.54 2 5
Average= 3.74
(KJ/cycle)

Cycle 109 GMT 8/ 7/2023 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 32 14.99 446 214 0.21 / 408.45 2 3
2 7 2003.08 32 14.90 2811 1340 1.55 / 409.79 2 3
3 13 1726.92 19 14.87 2512 710 2.26 / 410.50 2 3
4 13 1007.96 19 14.92 1629 462 2.73 / 410.97 2 3
5 13 442.28 19 15.01 870 248 2.97 / 411.21 2 3
6 8 0.20 165 15.04 271 673 3.65 / 411.89 2 5
Average= 3.74
(KJ/cycle)

Cycle 108 GMT 28/ 6/2023 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 32 14.99 425 204 0.20 / 404.62 3 3
2 7 2013.80 32 14.88 2877 1370 1.57 / 405.99 2 3
3 13 1601.00 19 14.87 2412 681 2.26 / 406.67 2 3
4 13 1151.12 19 14.88 1837 519 2.77 / 407.19 2 3
5 13 538.08 19 14.97 1015 289 3.06 / 407.48 2 3
6 13 39.64 19 15.06 336 96 3.16 / 407.58 2 3
7 8 -0.08 165 15.04 268 665 3.82 / 408.24 2 4
Average= 3.75
(KJ/cycle)

Cycle 107 GMT 18/ 6/2023 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 32 14.99 441 212 0.21 / 400.72 3 3
2 7 2005.16 32 14.87 2868 1365 1.58 / 402.09 2 4
3 13 1594.96 19 14.86 2412 681 2.26 / 402.77 2 3
4 13 1157.08 19 14.87 1841 520 2.78 / 403.29 2 3
5 13 406.20 19 14.99 849 242 3.02 / 403.53 2 3
6 13 45.12 19 15.05 351 100 3.12 / 403.63 2 2
7 8 -0.08 165 15.03 270 670 3.79 / 404.30 2 7
8 14 -0.08 30 15.01 261 118 3.91 / 404.42 4 7
Average= 3.74
(KJ/cycle)

Cycle 106 GMT 8/ 6/2023 9:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 32 14.99 431 207 0.21 / 396.86 2 3
2 7 2010.80 32 14.88 2881 1372 1.58 / 398.23 2 3
3 13 1600.44 19 14.86 2402 678 2.26 / 398.91 2 3
4 13 1154.20 19 14.88 1832 518 2.77 / 399.43 2 3
5 13 574.76 19 14.96 1078 306 3.08 / 399.73 2 3
6 13 47.48 19 15.06 346 99 3.18 / 399.83 2 3
7 8 0.04 165 15.03 273 677 3.86 / 400.51 2 5
Average= 3.74
(KJ/cycle)

Cycle 105 GMT 29/ 5/2023 12:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 32 15.00 428 205 0.21 / 393.13 2 3
2 7 2008.68 32 14.88 2851 1358 1.56 / 394.48 2 3
3 13 1595.04 19 14.85 2405 679 2.24 / 395.16 2 4
4 13 1151.92 19 14.86 1846 521 2.76 / 395.68 2 3
5 13 296.28 19 15.01 704 201 2.96 / 395.88 2 3
6 13 31.16 19 15.05 329 94 3.06 / 395.98 2 3
7 8 0.04 165 15.03 272 675 3.73 / 396.65 2 8
Average= 3.74
(KJ/cycle)

Cycle 104 GMT 19/ 5/2023 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 32 14.99 435 209 0.21 / 389.40 3 3
2 7 2011.68 32 14.89 2859 1362 1.57 / 390.76 2 3
3 13 1603.12 19 14.86 2440 689 2.26 / 391.45 2 3
4 13 1036.08 19 14.89 1722 487 2.75 / 391.93 2 3
5 13 328.48 19 15.02 750 214 2.96 / 392.15 2 3
6 13 36.88 19 15.07 336 96 3.06 / 392.25 2 2
7 8 -0.16 165 15.04 272 675 3.73 / 392.92 2 4
Average= 3.74
(KJ/cycle)

Cycle 103 GMT 9/ 5/2023 16:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 32 15.00 439 211 0.21 / 385.53 2 3
2 7 2004.80 32 14.88 2879 1371 1.58 / 386.90 2 3
3 13 1740.08 19 14.84 2567 724 2.31 / 387.62 2 4
4 13 1121.36 19 14.89 1806 511 2.82 / 388.14 2 3
5 13 524.32 19 14.97 989 281 3.10 / 388.42 2 3
6 13 37.56 19 15.07 318 91 3.19 / 388.51 2 3
7 8 0.04 165 15.04 274 680 3.87 / 389.19 2 6
Average= 3.74
(KJ/cycle)

Cycle 102 GMT 29/ 4/2023 19:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 32 15.00 441 212 0.21 / 381.68 3 3
2 7 2006.44 32 14.89 2881 1373 1.58 / 383.05 2 3
3 13 1731.60 19 14.87 2566 725 2.31 / 383.78 2 3
4 13 1151.60 19 14.89 1829 517 2.83 / 384.29 2 3
5 13 417.60 19 15.01 844 241 3.07 / 384.53 2 3
6 13 45.52 19 15.07 344 98 3.17 / 384.63 2 3
7 8 0.04 165 15.03 277 687 3.85 / 385.32 2 6
Average= 3.74
(KJ/cycle)

Cycle 101 GMT 19/ 4/2023 21:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 32 14.98 428 205 0.21 / 377.88 2 3
2 7 2009.68 32 14.88 2875 1369 1.57 / 379.25 2 3
3 13 1593.80 19 14.87 2400 678 2.25 / 379.93 2 3
4 13 1156.08 19 14.88 1849 523 2.77 / 380.45 2 3
5 13 411.28 19 15.00 851 243 3.02 / 380.69 2 3
6 13 23.68 19 15.07 323 92 3.11 / 380.79 2 3
7 8 -0.20 165 15.04 274 680 3.79 / 381.47 2 6
Average= 3.74
(KJ/cycle)

Cycle 100 GMT 9/ 4/2023 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 32 14.99 431 207 0.21 / 373.87 3 3
2 3 1023.28 1 15.17 1714 26 0.23 / 373.90 2 3
3 7 2003.68 33 14.89 2808 1380 1.61 / 375.28 2 2
4 13 1593.72 19 14.87 2390 675 2.29 / 375.95 2 4
5 13 1157.12 19 14.88 1859 526 2.81 / 376.48 2 3
6 13 543.24 19 14.96 1026 292 3.10 / 376.77 2 3
7 13 39.72 19 15.06 351 100 3.21 / 376.87 2 2
8 8 0.12 165 15.04 276 685 3.89 / 377.55 2 3
9 14 0.12 30 15.01 270 122 4.01 / 377.68 2 5
Average= 3.74
(KJ/cycle)

Cycle 99 GMT 31/ 3/2023 2: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 32 15.00 439 211 0.21 / 370.07 2 3
2 7 2007.68 32 14.90 2830 1349 1.56 / 371.42 2 3
3 13 1592.80 19 14.86 2409 680 2.24 / 372.10 2 3
4 13 1148.48 19 14.87 1858 525 2.77 / 372.63 2 3
5 13 387.80 19 15.00 842 240 3.01 / 372.87 2 3
6 13 44.00 19 15.05 353 101 3.11 / 372.97 2 3
7 8 0.32 165 15.03 280 694 3.80 / 373.66 2 4
Average= 3.74
(KJ/cycle)

Cycle 98 GMT 21/ 3/2023 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 32 14.97 422 202 0.20 / 366.36 2 3
2 7 2004.24 32 14.88 2869 1366 1.57 / 367.73 2 3
3 13 1583.48 19 14.87 2396 677 2.25 / 368.40 2 4
4 13 1023.56 19 14.91 1691 479 2.72 / 368.88 2 3
5 13 312.04 19 15.02 734 209 2.93 / 369.09 2 3
6 13 28.40 19 15.07 327 94 3.03 / 369.18 2 3
7 8 -0.20 165 15.04 274 680 3.71 / 369.86 2 7
Average= 3.74
(KJ/cycle)

Cycle 97 GMT 11/ 3/2023 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 32 15.00 432 207 0.21 / 362.25 3 3
2 7 2011.44 32 14.90 2873 1370 1.58 / 363.62 2 3
3 13 1729.40 19 14.86 2567 725 2.30 / 364.34 2 4
4 13 1021.72 19 14.91 1670 473 2.78 / 364.82 2 3
5 13 658.76 19 14.95 1181 335 3.11 / 365.15 2 3
6 13 575.68 19 14.94 1079 306 3.42 / 365.46 2 3
7 8 0.04 165 15.02 282 699 4.12 / 366.16 2 4
Average= 3.74
(KJ/cycle)

Cycle 96 GMT 1/ 3/2023 8:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 32 15.00 431 207 0.21 / 358.44 2 3
2 7 2007.00 32 14.90 2854 1361 1.57 / 359.80 2 3
3 13 1607.16 19 14.87 2420 684 2.25 / 360.49 2 3
4 13 1163.48 19 14.90 1856 525 2.78 / 361.01 2 3
5 13 409.88 19 15.00 876 250 3.03 / 361.26 2 3
6 13 20.64 19 15.07 315 90 3.12 / 361.35 2 3
7 8 0.16 165 15.04 277 687 3.80 / 362.04 2 5
Average= 3.73
(KJ/cycle)

Cycle 95 GMT 19/ 2/2023 11: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 32 15.00 436 209 0.21 / 354.50 3 3
2 7 2011.88 32 14.90 2885 1376 1.58 / 355.88 2 3
3 13 1732.88 19 14.86 2577 728 2.31 / 356.61 2 3
4 13 1272.60 19 14.88 2004 567 2.88 / 357.17 2 3
5 13 508.56 19 14.99 976 278 3.16 / 357.45 2 3
6 13 32.32 19 15.08 323 93 3.25 / 357.54 2 2
7 8 -0.04 165 15.04 279 692 3.94 / 358.24 2 4
Average= 3.73
(KJ/cycle)

Cycle 94 GMT 9/ 2/2023 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 32 14.99 429 206 0.21 / 350.66 2 3
2 7 2002.60 33 14.89 2859 1405 1.61 / 352.07 2 3
3 13 1593.08 19 14.87 2434 688 2.30 / 352.75 2 3
4 13 1149.20 19 14.88 1864 527 2.83 / 353.28 2 3
5 13 405.00 19 15.01 859 245 3.07 / 353.53 2 3
6 13 22.56 19 15.06 313 90 3.16 / 353.62 2 3
7 8 0.28 165 15.04 274 680 3.84 / 354.30 2 4
Average= 3.73
(KJ/cycle)

Cycle 93 GMT 30/ 1/2023 15:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 32 15.01 429 206 0.21 / 346.76 3 3
2 7 2011.04 32 14.90 2865 1366 1.57 / 348.13 2 3
3 13 1736.04 19 14.87 2579 729 2.30 / 348.86 2 3
4 13 1138.40 19 14.90 1822 516 2.82 / 349.38 2 3
5 13 550.20 19 14.98 1044 297 3.11 / 349.67 2 3
6 13 34.20 19 15.07 342 98 3.21 / 349.77 2 3
7 8 0.08 165 15.04 276 685 3.90 / 350.46 2 7
Average= 3.73
(KJ/cycle)

Cycle 92 GMT 20/ 1/2023 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 32 14.99 419 201 0.20 / 343.05 2 3
2 7 2007.88 32 14.90 2865 1366 1.57 / 344.42 2 4
3 13 1594.40 19 14.88 2402 679 2.25 / 345.10 2 3
4 13 1028.36 19 14.91 1681 476 2.72 / 345.57 2 3
5 13 317.48 19 15.03 715 204 2.93 / 345.78 2 3
6 13 31.84 19 15.08 334 96 3.02 / 345.87 2 3
7 8 -0.08 165 15.05 276 685 3.71 / 346.56 2 6
Average= 3.73
(KJ/cycle)

Cycle 91 GMT 10/ 1/2023 20:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 32 15.01 430 207 0.21 / 339.23 2 3
2 3 1016.12 1 15.19 1757 27 0.23 / 339.26 2 3
3 7 2004.60 32 14.89 2876 1370 1.60 / 340.63 2 3
4 13 1604.08 19 14.86 2427 685 2.29 / 341.32 2 3
5 13 1036.92 19 14.91 1726 489 2.78 / 341.80 2 3
6 13 441.64 19 15.00 920 262 3.04 / 342.07 2 3
7 13 19.92 19 15.07 314 90 3.13 / 342.16 2 2
8 8 0.00 165 15.04 280 695 3.82 / 342.85 2 6
Average= 3.73
(KJ/cycle)

Cycle 90 GMT 31/12/2022 22:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 32 15.01 417 200 0.20 / 335.38 2 3
2 7 2006.80 33 14.91 2838 1396 1.60 / 336.77 2 3
3 13 1730.60 19 14.88 2572 727 2.32 / 337.50 2 3
4 13 1131.12 19 14.90 1827 517 2.84 / 338.02 2 3
5 13 401.80 19 15.02 844 241 3.08 / 338.26 2 3
6 13 20.24 19 15.09 318 91 3.17 / 338.35 2 3
7 8 -0.12 165 15.05 272 675 3.85 / 339.03 2 3
Average= 3.73
(KJ/cycle)

Cycle 89 GMT 22/12/2022 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 31 15.04 450 210 0.21 / 331.68 2 3
2 7 2013.72 32 14.90 2862 1365 1.57 / 333.04 2 3
3 13 1489.84 19 14.88 2301 651 2.22 / 333.69 2 3
4 13 1078.44 19 14.89 1762 498 2.72 / 334.19 2 4
5 13 358.60 19 15.02 786 224 2.95 / 334.41 2 3
6 13 19.64 19 15.09 307 88 3.04 / 334.50 2 2
7 8 0.04 165 15.07 272 676 3.71 / 335.18 2 7
Average= 3.72
(KJ/cycle)

Cycle 88 GMT 12/12/2022 2:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 31 15.04 433 202 0.20 / 327.86 2 3
2 7 2005.44 32 14.91 2856 1363 1.56 / 329.22 2 4
3 13 1604.68 19 14.89 2425 686 2.25 / 329.91 2 3
4 13 1176.88 19 14.91 1866 529 2.78 / 330.43 2 3
5 13 432.80 19 15.03 885 253 3.03 / 330.69 2 3
6 13 19.96 19 15.10 316 91 3.12 / 330.78 2 3
7 8 0.08 165 15.07 277 689 3.81 / 331.47 2 5
Average= 3.72
(KJ/cycle)

Cycle 87 GMT 2/12/2022 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 31 15.05 428 200 0.20 / 324.16 2 3
2 7 2006.80 32 14.93 2843 1358 1.56 / 325.52 2 3
3 13 1603.80 19 14.89 2432 688 2.25 / 326.21 2 3
4 13 1047.56 19 14.93 1718 487 2.73 / 326.69 2 3
5 13 464.60 19 15.01 936 267 3.00 / 326.96 2 3
6 8 0.12 165 15.08 279 694 3.69 / 327.65 2 5
Average= 3.72
(KJ/cycle)

Cycle 86 GMT 22/11/2022 7:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 31 15.05 439 205 0.20 / 320.50 2 3
2 7 2008.28 33 14.91 2875 1415 1.62 / 321.91 2 3
3 13 1589.52 19 14.89 2413 683 2.30 / 322.59 2 3
4 13 1026.48 19 14.93 1677 476 2.78 / 323.07 2 3
5 13 316.84 19 15.07 705 202 2.98 / 323.27 2 3
6 8 0.16 165 15.09 277 690 3.67 / 323.96 2 4
Average= 3.72
(KJ/cycle)

Cycle 85 GMT 12/11/2022 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 31 15.04 430 200 0.20 / 316.73 2 3
2 7 2003.04 33 14.91 2881 1418 1.62 / 318.15 2 3
3 13 1590.36 19 14.90 2415 684 2.30 / 318.84 2 3
4 13 1147.28 19 14.91 1844 522 2.82 / 319.36 2 3
5 13 410.04 19 15.04 843 241 3.06 / 319.60 2 3
6 8 -0.08 165 15.09 278 692 3.76 / 320.29 2 6
Average= 3.72
(KJ/cycle)

Cycle 84 GMT 2/11/2022 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 31 15.04 430 200 0.20 / 313.03 2 3
2 7 2013.88 32 14.90 2900 1383 1.58 / 314.41 2 3
3 13 1597.20 19 14.89 2431 688 2.27 / 315.10 2 3
4 13 1025.00 19 14.92 1697 481 2.75 / 315.58 2 3
5 13 438.40 19 15.03 893 255 3.01 / 315.84 2 3
6 8 0.12 165 15.09 279 695 3.70 / 316.53 2 4
Average= 3.72
(KJ/cycle)

Cycle 83 GMT 23/10/2022 13:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 31 15.05 421 196 0.20 / 309.38 3 3
2 7 2006.80 32 14.90 2836 1352 1.55 / 310.73 2 3
3 13 1576.16 19 14.89 2387 675 2.22 / 311.41 2 3
4 13 1137.12 19 14.90 1851 524 2.75 / 311.93 2 3
5 13 263.28 19 15.06 658 188 2.94 / 312.12 2 3
6 8 0.00 165 15.10 285 710 3.65 / 312.83 2 3
Average= 3.72
(KJ/cycle)

Cycle 82 GMT 13/10/2022 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 15.05 432 202 0.20 / 305.68 2 3
2 7 2005.76 32 14.91 2837 1354 1.56 / 307.03 2 3
3 13 1565.92 19 14.92 2323 659 2.21 / 307.69 2 3
4 13 1014.96 19 14.94 1653 469 2.68 / 308.16 2 4
5 13 305.20 19 15.06 703 201 2.88 / 308.36 2 3
6 8 0.00 165 15.10 281 700 3.58 / 309.06 2 4
7 14 0.00 30 15.07 273 123 3.71 / 309.19 2 7
Average= 3.73
(KJ/cycle)

Cycle 81 GMT 3/10/2022 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 31 15.06 441 206 0.21 / 301.93 2 3
2 7 2004.08 32 14.90 2884 1375 1.58 / 303.30 2 3
3 13 1593.56 19 14.89 2400 679 2.26 / 303.98 2 3
4 13 1019.36 19 14.93 1669 473 2.73 / 304.45 2 3
5 13 295.28 19 15.07 679 194 2.93 / 304.65 2 3
6 8 0.12 165 15.09 283 705 3.63 / 305.35 2 4
7 14 0.12 30 15.07 276 125 3.76 / 305.48 2 6
Average= 3.73
(KJ/cycle)

Cycle 80 GMT 23/ 9/2022 20: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 31 15.05 441 206 0.21 / 298.26 2 3
2 7 2008.32 32 14.91 2880 1374 1.58 / 299.63 2 4
3 13 1587.92 19 14.89 2435 689 2.27 / 300.32 2 3
4 13 1022.76 19 14.94 1718 488 2.76 / 300.81 2 3
5 13 309.64 19 15.08 730 209 2.97 / 301.02 2 3
6 8 0.12 165 15.10 283 705 3.67 / 301.72 2 3
Average= 3.72
(KJ/cycle)

Cycle 79 GMT 13/ 9/2022 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 31 15.05 437 204 0.20 / 294.59 2 3
2 7 2007.52 32 14.92 2849 1360 1.56 / 295.95 2 3
3 13 1608.76 19 14.88 2426 686 2.25 / 296.63 2 3
4 13 1056.48 19 14.92 1740 493 2.74 / 297.13 2 3
5 13 349.04 19 15.05 788 225 2.97 / 297.35 2 2
6 8 0.08 165 15.09 281 700 3.67 / 298.05 2 6
Average= 3.73
(KJ/cycle)

Cycle 78 GMT 4/ 9/2022 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 31 15.06 451 211 0.21 / 290.80 2 3
2 7 2007.08 32 14.93 2876 1374 1.58 / 292.17 2 3
3 13 1589.92 19 14.91 2421 686 2.27 / 292.86 2 3
4 13 1153.76 19 14.93 1860 528 2.80 / 293.39 2 3
5 13 530.04 19 15.02 1031 294 3.09 / 293.68 2 3
6 8 0.16 165 15.09 282 702 3.79 / 294.38 2 5
Average= 3.73
(KJ/cycle)

Cycle 77 GMT 25/ 8/2022 2:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 31 15.06 438 204 0.20 / 287.00 2 3
2 7 2011.36 33 14.91 2865 1410 1.61 / 288.41 2 3
3 13 1598.36 19 14.90 2414 683 2.30 / 289.10 2 3
4 13 1050.04 19 14.93 1711 485 2.78 / 289.58 2 3
5 13 328.40 19 15.06 719 206 2.99 / 289.79 2 3
6 8 0.00 165 15.10 271 675 3.66 / 290.46 2 6
7 14 0.00 30 15.09 277 125 3.79 / 290.59 2 8
Average= 3.73
(KJ/cycle)

Cycle 76 GMT 15/ 8/2022 4:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 31 15.07 439 205 0.21 / 283.32 2 3
2 7 2004.76 32 14.91 2875 1372 1.58 / 284.70 2 3
3 13 1603.48 19 14.91 2415 684 2.26 / 285.38 2 3
4 13 1034.00 19 14.94 1693 481 2.74 / 285.86 2 3
5 13 441.84 19 15.04 881 252 2.99 / 286.11 2 3
6 8 0.16 165 15.10 275 685 3.68 / 286.80 2 5
Average= 3.72
(KJ/cycle)

Cycle 75 GMT 5/ 8/2022 7: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 31 15.06 428 200 0.20 / 279.66 2 3
2 7 2004.20 32 14.93 2874 1373 1.57 / 281.03 2 3
3 13 1600.24 19 14.92 2407 682 2.26 / 281.71 2 3
4 13 1047.28 19 14.94 1711 486 2.74 / 282.20 2 3
5 13 352.96 19 15.08 757 217 2.96 / 282.42 2 3
6 8 0.24 165 15.12 282 704 3.66 / 283.12 2 4
Average= 3.73
(KJ/cycle)

Cycle 74 GMT 26/ 7/2022 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 31 15.08 445 208 0.21 / 275.91 2 3
2 7 2007.32 32 14.92 2879 1375 1.58 / 277.28 2 2
3 13 1593.52 19 14.91 2417 685 2.27 / 277.97 2 3
4 13 1028.84 19 14.95 1690 480 2.75 / 278.45 2 3
5 13 584.36 19 15.02 1085 310 3.06 / 278.76 2 3
6 8 0.04 165 15.11 281 701 3.76 / 279.46 2 5
Average= 3.73
(KJ/cycle)

Cycle 73 GMT 16/ 7/2022 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 31 15.08 436 204 0.20 / 272.24 2 3
2 7 2007.16 32 14.93 2872 1372 1.58 / 273.61 2 3
3 13 1603.48 19 14.92 2425 687 2.26 / 274.30 2 3
4 13 1037.28 19 14.95 1703 484 2.75 / 274.78 2 3
5 13 321.08 19 15.08 733 210 2.96 / 274.99 2 3
6 8 0.16 165 15.11 284 708 3.67 / 275.70 2 4
Average= 3.73
(KJ/cycle)

Cycle 72 GMT 6/ 7/2022 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 32 15.07 449 217 0.22 / 268.51 2 3
2 7 2004.68 32 14.93 2852 1363 1.58 / 269.88 2 3
3 13 1587.60 19 14.91 2396 679 2.26 / 270.56 2 3
4 13 1152.24 19 14.93 1856 526 2.78 / 271.08 2 3
5 13 409.44 19 15.06 866 248 3.03 / 271.33 2 3
6 8 -0.16 165 15.11 283 706 3.74 / 272.04 2 4
Average= 3.73
(KJ/cycle)

Cycle 71 GMT 26/ 6/2022 15:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 15.07 440 212 0.21 / 264.80 2 3
2 7 2004.40 32 14.92 2841 1356 1.57 / 266.15 2 3
3 13 1580.96 19 14.92 2399 680 2.25 / 266.83 2 3
4 13 1142.36 19 14.93 1840 522 2.77 / 267.36 2 3
5 13 391.84 19 15.07 840 241 3.01 / 267.60 2 3
6 8 -0.08 165 15.12 281 701 3.71 / 268.30 2 4
Average= 3.73
(KJ/cycle)

Cycle 70 GMT 16/ 6/2022 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 32 15.09 439 212 0.21 / 261.05 2 3
2 7 2009.36 32 14.93 2875 1374 1.59 / 262.42 2 3
3 13 1595.44 19 14.91 2412 683 2.27 / 263.11 2 3
4 13 1037.60 19 14.95 1686 479 2.75 / 263.58 2 3
5 13 316.68 19 15.09 714 205 2.95 / 263.79 2 3
6 13 28.24 19 15.13 343 99 3.05 / 263.89 2 3
7 8 0.00 165 15.11 280 698 3.75 / 264.59 2 3
Average= 3.73
(KJ/cycle)

Cycle 69 GMT 6/ 6/2022 20:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 32 15.09 449 217 0.22 / 257.28 2 3
2 7 2006.92 32 14.95 2838 1358 1.57 / 258.64 2 3
3 13 1729.04 19 14.92 2551 723 2.30 / 259.36 2 3
4 13 1140.72 19 14.95 1832 520 2.82 / 259.88 2 3
5 13 438.72 19 15.07 883 253 3.07 / 260.13 2 3
6 8 0.12 165 15.13 282 704 3.77 / 260.84 2 8
Average= 3.73
(KJ/cycle)

Cycle 68 GMT 27/ 5/2022 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 32 15.08 449 217 0.22 / 253.51 2 3
2 7 2004.12 32 14.95 2859 1368 1.58 / 254.88 2 3
3 13 1606.24 19 14.93 2427 688 2.27 / 255.57 2 3
4 13 1162.60 19 14.93 1879 533 2.81 / 256.10 2 3
5 13 417.72 19 15.07 885 253 3.06 / 256.35 2 3
6 8 0.12 165 15.14 283 707 3.77 / 257.06 2 5
Average= 3.73
(KJ/cycle)

Cycle 67 GMT 18/ 5/2022 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 32 15.08 437 211 0.21 / 249.79 2 3
2 7 2008.84 32 14.94 2860 1367 1.58 / 251.16 2 3
3 13 1595.16 19 14.93 2417 686 2.26 / 251.84 2 3
4 13 1027.00 19 14.97 1714 488 2.75 / 252.33 2 3
5 13 430.44 19 15.08 914 262 3.01 / 252.59 2 3
6 8 -0.12 165 15.14 281 702 3.72 / 253.30 2 8
Average= 3.72
(KJ/cycle)

Cycle 66 GMT 8/ 5/2022 2:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 31 15.09 454 212 0.21 / 246.16 2 3
2 7 2019.52 32 14.95 2840 1359 1.57 / 247.52 2 3
3 13 1481.84 19 14.92 2267 643 2.21 / 248.16 2 4
4 13 1063.72 19 14.95 1745 496 2.71 / 248.66 2 3
5 13 332.68 19 15.08 757 217 2.93 / 248.87 2 3
6 8 0.20 165 15.12 283 706 3.63 / 249.58 2 4
Average= 3.73
(KJ/cycle)

Cycle 65 GMT 28/ 4/2022 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 31 15.11 467 219 0.22 / 242.46 2 3
2 7 2005.88 32 14.94 2870 1372 1.59 / 243.83 2 3
3 13 1594.20 19 14.92 2420 686 2.28 / 244.52 2 3
4 13 1030.48 19 14.97 1722 490 2.77 / 245.01 2 3
5 13 328.56 19 15.10 762 219 2.99 / 245.23 2 3
6 8 0.04 165 15.13 288 719 3.70 / 245.95 2 4
Average= 3.73
(KJ/cycle)

Cycle 64 GMT 18/ 4/2022 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 31 15.09 448 210 0.21 / 238.77 2 3
2 7 2010.28 32 14.95 2865 1371 1.58 / 240.14 2 3
3 13 1602.72 19 14.93 2420 686 2.27 / 240.82 2 4
4 13 1026.16 19 14.97 1708 486 2.75 / 241.31 2 3
5 13 314.64 19 15.12 743 213 2.97 / 241.52 2 2
6 8 0.00 165 15.15 288 720 3.69 / 242.24 2 7
Average= 3.73
(KJ/cycle)

Cycle 63 GMT 8/ 4/2022 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 31 15.10 448 210 0.21 / 234.77 2 3
2 7 2003.56 32 14.97 2858 1369 1.58 / 236.14 2 3
3 13 1599.80 19 14.94 2443 693 2.27 / 236.84 2 3
4 13 1152.08 19 14.95 1872 532 2.80 / 237.37 2 3
5 13 418.80 19 15.10 889 255 3.06 / 237.62 2 3
6 13 21.68 19 15.17 326 94 3.15 / 237.72 2 3
7 8 0.28 165 15.14 286 714 3.87 / 238.43 2 4
8 14 0.28 30 15.12 280 127 3.99 / 238.56 2 6
Average= 3.73
(KJ/cycle)

Cycle 62 GMT 29/ 3/2022 11:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 31 15.11 429 201 0.20 / 230.85 2 3
2 7 2011.52 32 14.96 2873 1375 1.58 / 232.23 2 3
3 13 1595.96 19 14.93 2420 686 2.26 / 232.91 2 3
4 13 1162.00 19 14.95 1890 537 2.80 / 233.45 2 3
5 13 555.36 19 15.06 1069 306 3.11 / 233.75 2 3
6 13 21.40 19 15.16 327 94 3.20 / 233.85 2 3
7 8 -0.08 165 15.14 286 714 3.91 / 234.56 2 3
Average= 3.72
(KJ/cycle)

Cycle 61 GMT 19/ 3/2022 14: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 32 15.11 446 216 0.22 / 227.19 2 3
2 7 2003.00 32 14.94 2857 1366 1.58 / 228.55 2 3
3 13 1582.28 19 14.92 2392 678 2.26 / 229.23 2 5
4 13 1017.80 19 14.98 1666 474 2.73 / 229.70 2 3
5 13 425.16 19 15.10 861 247 2.98 / 229.95 2 3
6 8 0.16 165 15.15 279 697 3.68 / 230.65 2 4
Average= 3.72
(KJ/cycle)

Cycle 60 GMT 9/ 3/2022 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 31 15.11 453 212 0.21 / 223.41 2 3
2 3 1020.52 1 15.25 1741 27 0.24 / 223.44 2 3
3 7 2007.56 33 14.98 2806 1387 1.63 / 224.82 2 2
4 13 1602.48 19 14.94 2397 680 2.31 / 225.50 2 4
5 13 1154.60 19 14.97 1828 520 2.83 / 226.02 2 3
6 13 408.52 19 15.11 817 235 3.06 / 226.26 2 3
7 8 0.12 165 15.17 285 713 3.77 / 226.97 2 6
Average= 3.72
(KJ/cycle)

Cycle 59 GMT 27/ 2/2022 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 31 15.13 461 216 0.22 / 219.49 2 3
2 7 2009.20 32 14.95 2881 1378 1.59 / 220.87 2 3
3 13 1593.32 19 14.94 2447 695 2.29 / 221.56 2 3
4 13 1150.12 19 14.97 1883 536 2.82 / 222.10 2 3
5 13 391.84 19 15.12 852 245 3.07 / 222.34 2 2
6 13 18.56 19 15.19 340 98 3.17 / 222.44 2 2
7 8 -0.08 165 15.16 303 758 3.93 / 223.20 2 5
Average= 3.72
(KJ/cycle)

Cycle 58 GMT 17/ 2/2022 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 31 15.15 457 215 0.21 / 215.67 2 3
2 7 2008.16 32 14.98 2844 1363 1.58 / 217.03 2 3
3 13 1607.08 19 14.94 2433 691 2.27 / 217.72 2 3
4 13 1053.64 19 15.00 1714 488 2.76 / 218.21 2 3
5 13 465.00 19 15.11 928 266 3.02 / 218.48 2 3
6 13 22.32 19 15.20 316 91 3.11 / 218.57 2 2
7 8 0.00 165 15.17 281 703 3.82 / 219.27 2 5
Average= 3.72
(KJ/cycle)

Cycle 57 GMT 7/ 2/2022 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 31 15.13 458 215 0.21 / 211.88 2 3
2 7 2005.80 33 14.98 2852 1410 1.62 / 213.29 2 3
3 13 1595.84 19 14.97 2389 680 2.30 / 213.97 2 3
4 13 1028.64 19 15.02 1684 481 2.78 / 214.45 2 4
5 13 309.52 19 15.17 704 203 2.99 / 214.65 2 3
6 13 28.24 19 15.23 307 89 3.08 / 214.74 2 2
7 8 0.12 165 15.20 283 710 3.79 / 215.45 2 4
Average= 3.71
(KJ/cycle)

Cycle 56 GMT 29/ 1/2022 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 31 15.15 459 216 0.22 / 208.02 2 3
2 7 2008.04 32 14.98 2860 1371 1.59 / 209.40 2 3
3 13 1600.32 19 14.94 2434 691 2.28 / 210.09 2 4
4 13 1037.52 19 15.01 1711 488 2.77 / 210.57 2 3
5 13 450.68 19 15.13 938 270 3.04 / 210.84 2 3
6 13 20.80 19 15.20 336 97 3.13 / 210.94 2 2
7 8 -0.08 165 15.18 290 726 3.86 / 211.67 2 4
Average= 3.71
(KJ/cycle)

Cycle 55 GMT 19/ 1/2022 3:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 31 15.16 467 219 0.22 / 204.23 2 3
2 7 2003.32 32 14.96 2869 1373 1.59 / 205.61 2 3
3 13 1593.88 19 14.95 2413 685 2.28 / 206.29 2 5
4 13 1144.04 19 15.00 1836 523 2.80 / 206.82 2 3
5 13 393.44 19 15.14 852 245 3.05 / 207.06 2 3
6 8 0.00 165 15.19 298 747 3.79 / 207.81 2 4
Average= 3.71
(KJ/cycle)

Cycle 54 GMT 9/ 1/2022 5:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 31 15.16 448 211 0.21 / 200.37 2 3
2 7 2008.48 32 14.98 2866 1374 1.58 / 201.74 2 3
3 13 1727.52 19 14.96 2582 734 2.32 / 202.47 2 3
4 13 1122.76 19 15.01 1808 516 2.83 / 202.99 2 3
5 13 513.16 19 15.14 990 285 3.12 / 203.27 2 3
6 8 -0.32 165 15.21 295 740 3.86 / 204.01 2 5
Average= 3.71
(KJ/cycle)

Cycle 53 GMT 30/12/2021 8: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 31 15.18 460 216 0.22 / 196.67 2 3
2 7 2011.80 32 14.99 2867 1375 1.59 / 198.04 2 3
3 13 1609.92 19 14.97 2423 689 2.28 / 198.73 2 3
4 13 1044.96 19 15.03 1704 487 2.77 / 199.22 2 3
5 13 321.92 19 15.18 725 209 2.98 / 199.43 2 3
6 8 0.32 165 15.21 291 730 3.71 / 200.16 2 7
Average= 3.71
(KJ/cycle)

Cycle 52 GMT 20/12/2021 10: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 31 15.18 466 219 0.22 / 192.96 2 3
2 7 2003.68 32 14.99 2865 1374 1.59 / 194.33 2 4
3 13 1614.68 19 14.96 2438 693 2.29 / 195.02 2 3
4 13 1041.04 19 15.03 1706 487 2.77 / 195.51 2 3
5 13 316.08 19 15.18 720 208 2.98 / 195.72 2 3
6 8 0.00 165 15.21 291 730 3.71 / 196.45 2 4
Average= 3.71
(KJ/cycle)

Cycle 51 GMT 10/12/2021 12:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 31 15.19 455 214 0.21 / 189.10 2 3
2 7 2006.52 32 14.99 2864 1374 1.59 / 190.47 2 3
3 13 1739.04 19 14.95 2607 741 2.33 / 191.21 2 3
4 13 1134.12 19 15.01 1850 528 2.86 / 191.74 2 3
5 13 389.88 19 15.17 856 247 3.10 / 191.99 2 3
6 8 0.04 165 15.22 299 751 3.85 / 192.74 2 6
Average= 3.71
(KJ/cycle)

Cycle 50 GMT 30/11/2021 14:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 15.18 469 221 0.22 / 185.34 2 3
2 7 2008.04 32 15.00 2860 1373 1.59 / 186.72 2 3
3 13 1598.40 19 14.98 2416 688 2.28 / 187.40 2 3
4 13 1047.20 19 15.04 1715 490 2.77 / 187.89 2 3
5 13 461.04 19 15.14 914 263 3.03 / 188.16 2 3
6 8 0.08 165 15.22 289 726 3.76 / 188.88 2 4
Average= 3.70
(KJ/cycle)

Cycle 49 GMT 20/11/2021 16:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 31 15.20 471 222 0.22 / 181.48 2 3
2 7 2004.00 32 15.00 2863 1374 1.60 / 182.86 2 3
3 13 1723.60 19 14.97 2568 730 2.33 / 183.59 2 3
4 13 1118.20 19 15.01 1831 522 2.85 / 184.11 2 3
5 13 375.88 19 15.19 842 243 3.09 / 184.35 2 3
6 8 0.36 165 15.23 307 771 3.86 / 185.12 2 4
Average= 3.70
(KJ/cycle)

Cycle 48 GMT 10/11/2021 19: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 31 15.20 453 213 0.21 / 177.80 2 3
2 7 2009.60 32 15.00 2859 1372 1.59 / 179.17 2 3
3 13 1596.36 19 14.99 2414 688 2.27 / 179.86 2 3
4 13 1028.36 19 15.06 1691 484 2.76 / 180.34 2 3
5 13 298.48 19 15.22 692 200 2.96 / 180.54 2 3
6 8 -0.20 165 15.25 286 720 3.68 / 181.26 2 4
Average= 3.70
(KJ/cycle)

Cycle 47 GMT 31/10/2021 21:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 31 15.20 459 216 0.22 / 174.07 2 3
2 7 2007.72 32 14.99 2862 1373 1.59 / 175.45 2 3
3 13 1603.52 19 14.98 2433 692 2.28 / 176.14 2 3
4 13 1036.44 19 15.05 1722 492 2.77 / 176.63 2 3
5 13 312.92 19 15.20 748 216 2.99 / 176.85 2 3
6 8 0.20 165 15.25 292 735 3.72 / 177.58 2 4
Average= 3.70
(KJ/cycle)

Cycle 46 GMT 21/10/2021 23:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 31 15.20 473 223 0.22 / 170.35 2 3
2 7 2003.04 32 15.01 2868 1378 1.60 / 171.73 2 3
3 13 1598.88 19 14.98 2418 688 2.29 / 172.42 2 3
4 13 1035.96 19 15.04 1694 484 2.77 / 172.90 2 3
5 13 319.00 19 15.20 743 215 2.99 / 173.12 2 3
6 8 0.00 165 15.24 294 739 3.73 / 173.86 2 4
Average= 3.70
(KJ/cycle)

Cycle 45 GMT 12/10/2021 1:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 31 15.21 476 224 0.22 / 166.50 2 3
2 7 2010.08 32 15.01 2884 1385 1.61 / 167.89 2 3
3 13 1605.40 19 15.00 2423 691 2.30 / 168.58 2 3
4 13 1164.48 19 15.04 1864 533 2.83 / 169.11 2 3
5 13 412.48 19 15.20 847 245 3.08 / 169.35 2 3
6 8 -0.04 165 15.25 309 778 3.86 / 170.13 2 4
Average= 3.70
(KJ/cycle)

Cycle 44 GMT 2/10/2021 4:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 31 15.21 470 222 0.22 / 162.66 2 3
2 7 2010.04 33 15.02 2894 1434 1.66 / 164.09 2 3
3 13 1589.80 19 14.99 2451 698 2.35 / 164.79 2 3
4 13 1031.88 19 15.06 1727 494 2.85 / 165.28 2 3
5 13 310.48 19 15.23 748 216 3.06 / 165.50 2 3
6 8 -0.08 165 15.26 309 778 3.84 / 166.28 2 3
Average= 3.70
(KJ/cycle)

Cycle 43 GMT 22/ 9/2021 6:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 31 15.21 456 215 0.22 / 158.69 2 3
2 7 2011.72 33 15.01 2878 1426 1.64 / 160.12 2 3
3 13 1601.36 19 15.00 2448 698 2.34 / 160.82 2 3
4 13 1031.04 19 15.07 1726 494 2.83 / 161.31 2 3
5 13 310.32 19 15.23 740 214 3.05 / 161.52 2 2
6 8 0.16 165 15.27 308 776 3.82 / 162.30 2 9
7 14 0.16 30 15.24 293 134 3.96 / 162.43 2 9
Average= 3.69
(KJ/cycle)

Cycle 42 GMT 12/ 9/2021 8:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 31 15.23 480 227 0.23 / 154.88 2 3
2 7 2010.84 32 15.02 2890 1389 1.62 / 156.27 2 3
3 13 1603.12 19 15.00 2432 693 2.31 / 156.96 2 3
4 13 1028.36 19 15.07 1692 484 2.79 / 157.45 2 3
5 13 426.40 19 15.20 899 260 3.05 / 157.71 2 3
6 8 0.16 165 15.25 307 772 3.83 / 158.48 2 3
Average= 3.69
(KJ/cycle)

Cycle 41 GMT 2/ 9/2021 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 31 15.24 468 221 0.22 / 151.14 2 3
2 7 2004.92 32 15.03 2869 1380 1.60 / 152.52 2 3
3 13 1597.60 19 15.00 2451 699 2.30 / 153.22 2 3
4 13 1013.72 19 15.09 1690 485 2.78 / 153.71 2 3
5 13 176.52 19 15.28 562 163 2.95 / 153.87 2 3
6 8 0.36 165 15.28 311 784 3.73 / 154.65 2 4
Average= 3.68
(KJ/cycle)

Cycle 40 GMT 23/ 8/2021 13:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 31 15.24 475 224 0.22 / 147.30 2 3
2 7 2007.12 32 15.02 2882 1385 1.61 / 148.69 2 3
3 13 1590.88 19 15.01 2435 694 2.30 / 149.38 2 3
4 13 1025.44 19 15.09 1719 493 2.80 / 149.87 2 3
5 13 431.36 19 15.22 903 261 3.06 / 150.13 2 2
6 8 -0.04 165 15.27 312 786 3.84 / 150.92 2 4
Average= 3.68
(KJ/cycle)

Cycle 39 GMT 13/ 8/2021 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 31 15.25 475 225 0.22 / 143.40 2 3
2 7 2007.56 32 15.03 2874 1382 1.61 / 144.78 2 3
3 13 1608.40 19 15.02 2438 696 2.30 / 145.48 2 3
4 13 1159.48 19 15.06 1873 536 2.84 / 146.01 2 3
5 13 404.36 19 15.23 877 254 3.09 / 146.27 2 3
6 8 -0.04 165 15.28 321 809 3.90 / 147.08 2 3
Average= 3.68
(KJ/cycle)

Cycle 38 GMT 3/ 8/2021 17:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 15.24 488 231 0.23 / 139.59 2 3
2 7 2003.96 32 15.01 2873 1380 1.61 / 140.97 2 3
3 13 1585.64 19 15.01 2439 696 2.31 / 141.67 2 3
4 13 1020.12 19 15.09 1729 496 2.80 / 142.16 2 3
5 13 294.92 19 15.26 729 211 3.01 / 142.38 2 3
6 8 0.16 165 15.28 317 799 3.81 / 143.18 2 7
Average= 3.67
(KJ/cycle)

Cycle 37 GMT 24/ 7/2021 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 30 15.24 490 224 0.22 / 135.61 2 3
2 7 2003.72 33 15.01 2868 1421 1.64 / 137.03 2 3
3 13 1597.56 19 15.01 2416 689 2.33 / 137.72 2 4
4 13 1017.16 19 15.09 1701 488 2.82 / 138.21 2 3
5 13 291.16 19 15.27 727 211 3.03 / 138.42 2 3
6 8 -0.08 165 15.28 317 799 3.83 / 139.22 2 3
7 14 -0.08 30 15.26 316 145 3.98 / 139.36 2 3
Average= 3.67
(KJ/cycle)

Cycle 36 GMT 14/ 7/2021 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 30 15.25 482 221 0.22 / 131.81 2 3
2 7 2010.52 32 15.02 2877 1383 1.60 / 133.19 2 3
3 13 1583.44 19 15.01 2445 697 2.30 / 133.89 2 4
4 13 1018.76 19 15.09 1725 495 2.80 / 134.38 2 3
5 13 298.76 19 15.25 734 213 3.01 / 134.60 2 3
6 8 0.12 165 15.29 313 790 3.80 / 135.39 2 5
Average= 3.66
(KJ/cycle)

Cycle 35 GMT 5/ 7/2021 0:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 30 15.25 484 221 0.22 / 127.93 2 3
2 7 2006.60 32 15.04 2863 1378 1.60 / 129.31 2 3
3 13 1594.28 19 15.02 2424 692 2.29 / 130.00 2 3
4 13 1139.64 19 15.07 1874 537 2.83 / 130.54 2 3
5 13 395.60 19 15.23 872 252 3.08 / 130.79 2 3
6 8 0.32 165 15.29 316 797 3.88 / 131.59 2 3
Average= 3.66
(KJ/cycle)

Cycle 34 GMT 25/ 6/2021 2:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 30 15.25 474 217 0.22 / 123.99 2 3
2 7 2005.52 32 15.04 2890 1391 1.61 / 125.38 2 3
3 13 1597.88 19 15.02 2439 696 2.30 / 126.08 2 3
4 13 1027.32 19 15.10 1730 496 2.80 / 126.57 2 3
5 13 311.08 19 15.26 750 217 3.02 / 126.79 2 3
6 8 -0.04 165 15.30 309 780 3.80 / 127.57 2 7
7 14 -0.04 30 15.27 312 143 3.94 / 127.71 2 6
Average= 3.65
(KJ/cycle)

Cycle 33 GMT 15/ 6/2021 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 30 15.24 483 221 0.22 / 120.23 2 3
2 7 2005.84 32 15.02 2873 1381 1.60 / 121.61 2 3
3 13 1582.72 19 15.03 2399 685 2.29 / 122.29 2 3
4 13 1011.88 19 15.11 1668 479 2.77 / 122.77 2 3
5 13 276.76 19 15.27 692 201 2.97 / 122.97 2 3
6 8 0.12 165 15.29 317 800 3.77 / 123.77 2 4
Average= 3.64
(KJ/cycle)

Cycle 32 GMT 5/ 6/2021 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 30 15.24 468 214 0.21 / 116.39 2 3
2 7 2004.20 32 15.04 2880 1386 1.60 / 117.77 2 3
3 13 1588.64 19 15.01 2456 700 2.30 / 118.47 2 3
4 13 1039.08 19 15.10 1750 502 2.80 / 118.98 2 3
5 13 318.64 19 15.25 768 223 3.03 / 119.20 2 3
6 8 0.16 165 15.29 320 807 3.83 / 120.01 2 4
Average= 3.64
(KJ/cycle)

Cycle 31 GMT 26/ 5/2021 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 15.25 487 223 0.22 / 112.29 2 3
2 7 2003.16 32 15.05 2880 1387 1.61 / 113.68 2 3
3 13 1736.24 19 15.00 2647 754 2.36 / 114.44 2 3
4 13 1119.48 19 15.09 1869 536 2.90 / 114.97 2 3
5 13 380.84 19 15.26 852 247 3.15 / 115.22 2 3
6 8 0.32 165 15.29 320 807 3.95 / 116.03 2 4
7 14 0.32 30 15.28 320 147 4.10 / 116.17 2 5
Average= 3.63
(KJ/cycle)

Cycle 30 GMT 16/ 5/2021 11: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 30 15.24 480 219 0.22 / 108.34 2 3
2 7 2004.60 32 15.05 2866 1380 1.60 / 109.72 2 3
3 13 1583.32 19 15.04 2460 703 2.30 / 110.42 2 4
4 13 1136.88 19 15.09 1885 540 2.84 / 110.96 2 3
5 13 517.60 19 15.22 1045 302 3.15 / 111.26 2 3
6 8 0.12 165 15.29 320 807 3.95 / 112.07 2 4
Average= 3.62
(KJ/cycle)

Cycle 29 GMT 6/ 5/2021 13:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 30 15.26 473 217 0.22 / 104.47 2 3
2 7 2006.20 32 15.04 2885 1388 1.61 / 105.86 2 3
3 13 1585.60 19 15.05 2421 692 2.30 / 106.55 2 3
4 13 1021.04 19 15.12 1732 498 2.79 / 107.05 2 3
5 13 166.04 19 15.31 549 160 2.95 / 107.21 2 2
6 13 30.44 19 15.33 363 106 3.06 / 107.31 2 3
7 8 0.16 165 15.30 320 808 3.87 / 108.12 2 4
Average= 3.60
(KJ/cycle)

Cycle 28 GMT 26/ 4/2021 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 30 15.30 415 190 0.19 / 100.71 2 3
2 7 2002.00 32 15.05 2862 1378 1.57 / 102.09 2 3
3 13 1580.12 19 15.06 2393 685 2.25 / 102.77 2 3
4 13 1007.04 19 15.13 1667 479 2.73 / 103.25 2 3
5 13 273.72 19 15.31 651 189 2.92 / 103.44 2 3
6 8 -0.12 165 15.31 320 808 3.73 / 104.25 2 3
Average= 3.59
(KJ/cycle)

Cycle 27 GMT 16/ 4/2021 17:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 30 15.30 406 186 0.19 / 97.10 2 3
2 7 2002.12 33 15.07 2852 1418 1.60 / 98.52 2 3
3 13 1582.44 19 15.06 2406 688 2.29 / 99.20 2 3
4 13 1002.12 19 15.15 1651 475 2.77 / 99.68 2 3
5 13 264.12 19 15.32 635 185 2.95 / 99.86 2 3
6 8 0.12 165 15.34 259 656 3.61 / 100.52 2 4
Average= 3.59
(KJ/cycle)

Cycle 26 GMT 6/ 4/2021 20:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 30 15.29 412 189 0.19 / 93.42 2 3
2 7 2007.92 32 15.07 2842 1371 1.56 / 94.79 2 3
3 13 1606.40 19 15.07 2405 689 2.25 / 95.48 2 3
4 13 1163.88 19 15.11 1859 534 2.78 / 96.01 2 3
5 13 416.88 19 15.26 836 242 3.02 / 96.26 2 3
6 8 0.32 165 15.34 259 656 3.68 / 96.91 2 4
Average= 3.59
(KJ/cycle)

Cycle 25 GMT 27/ 3/2021 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 30 15.28 414 190 0.19 / 89.76 3 3
2 7 2006.56 32 15.06 2866 1381 1.57 / 91.14 2 3
3 13 1584.60 19 15.05 2392 684 2.25 / 91.82 2 4
4 13 1007.08 19 15.15 1659 478 2.73 / 92.30 2 3
5 13 282.56 19 15.30 660 192 2.92 / 92.49 2 3
6 13 19.80 19 15.35 291 85 3.01 / 92.58 2 2
7 8 0.00 165 15.33 259 655 3.66 / 93.23 2 5
Average= 3.59
(KJ/cycle)

Cycle 24 GMT 18/ 3/2021 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 30 15.29 415 190 0.19 / 86.09 2 3
2 7 2007.56 32 15.09 2859 1381 1.57 / 87.47 2 3
3 13 1587.88 18 15.08 2410 654 2.23 / 88.12 2 3
4 13 1033.56 18 15.14 1693 461 2.69 / 88.58 2 3
5 13 452.32 18 15.27 894 246 2.93 / 88.83 2 3
6 13 24.92 18 15.35 302 83 3.02 / 88.91 2 3
7 8 -0.08 165 15.33 259 655 3.67 / 89.57 2 7
Average= 3.58
(KJ/cycle)

Cycle 23 GMT 8/ 3/2021 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 30 15.29 410 188 0.19 / 82.39 2 3
2 7 2002.56 33 15.07 2850 1417 1.61 / 83.81 2 3
3 13 1569.36 18 15.08 2392 649 2.25 / 84.46 2 3
4 13 1009.20 18 15.16 1669 455 2.71 / 84.91 2 3
5 13 422.44 18 15.28 866 238 2.95 / 85.15 2 3
6 13 23.96 18 15.36 302 83 3.03 / 85.24 2 2
7 8 -0.04 165 15.33 261 660 3.69 / 85.90 2 4
Average= 3.58
(KJ/cycle)

Cycle 22 GMT 26/ 2/2021 4:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 15.29 405 186 0.19 / 78.90 2 3
2 7 2006.20 32 15.06 2852 1374 1.56 / 80.27 2 3
3 13 1474.12 18 15.09 2259 614 2.17 / 80.88 2 3
4 13 1056.16 18 15.14 1723 470 2.64 / 81.35 2 4
5 13 325.68 18 15.30 727 200 2.84 / 81.55 2 3
6 8 0.24 165 15.33 257 650 3.49 / 82.20 2 3
Average= 3.57
(KJ/cycle)

Cycle 21 GMT 16/ 2/2021 6:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 30 15.31 412 189 0.19 / 75.23 2 3
2 7 2006.16 32 15.08 2871 1385 1.57 / 76.61 2 3
3 13 1595.24 18 15.07 2419 656 2.23 / 77.27 2 3
4 13 1023.12 18 15.16 1680 458 2.69 / 77.73 2 3
5 13 444.28 18 15.27 889 244 2.93 / 77.97 2 3
6 13 23.84 18 15.36 299 83 3.02 / 78.06 2 2
7 8 0.08 165 15.34 259 656 3.67 / 78.71 2 8
Average= 3.58
(KJ/cycle)

Cycle 20 GMT 6/ 2/2021 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 30 15.31 419 192 0.19 / 71.59 2 3
2 7 2005.08 32 15.08 2868 1384 1.58 / 72.98 2 5
3 13 1602.20 18 15.09 2424 658 2.23 / 73.64 2 6
4 13 1042.16 18 15.17 1708 466 2.70 / 74.10 2 3
5 13 327.68 18 15.32 731 202 2.90 / 74.30 2 3
6 13 15.60 18 15.37 286 79 2.98 / 74.38 2 2
7 8 0.20 165 15.34 259 656 3.64 / 75.04 2 4
Average= 3.57
(KJ/cycle)

Cycle 19 GMT 27/ 1/2021 11: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 30 15.31 409 188 0.19 / 68.05 2 3
2 7 2010.68 32 15.06 2872 1384 1.57 / 69.44 2 3
3 13 1594.84 18 15.08 2426 659 2.23 / 70.09 2 3
4 13 1018.96 18 15.16 1671 456 2.69 / 70.55 2 3
5 13 310.04 18 15.30 700 193 2.88 / 70.74 2 3
6 8 0.28 165 15.34 260 658 3.54 / 71.40 2 7
Average= 3.57
(KJ/cycle)

Cycle 18 GMT 17/ 1/2021 13: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 15.30 410 188 0.19 / 64.52 2 3
2 7 2004.28 32 15.09 2859 1381 1.57 / 65.90 2 3
3 13 1580.44 17 15.09 2388 613 2.18 / 66.51 2 6
4 13 1148.04 17 15.14 1837 473 2.65 / 66.98 2 3
5 13 418.44 17 15.29 852 221 2.88 / 67.20 2 3
6 8 0.12 165 15.35 261 661 3.54 / 67.86 2 3
Average= 3.57
(KJ/cycle)

Cycle 17 GMT 7/ 1/2021 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 30 15.32 414 190 0.19 / 60.94 2 3
2 7 2002.96 32 15.08 2869 1384 1.57 / 62.33 2 3
3 13 1574.12 17 15.10 2379 611 2.19 / 62.94 2 3
4 13 1019.76 17 15.16 1680 433 2.62 / 63.37 2 4
5 13 448.48 17 15.29 891 232 2.85 / 63.60 2 3
6 13 23.76 17 15.38 296 77 2.93 / 63.68 2 2
7 8 0.12 165 15.34 256 648 3.58 / 64.33 2 6
Average= 3.57
(KJ/cycle)

Cycle 16 GMT 28/12/2020 17:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 30 15.31 424 195 0.19 / 57.42 2 3
2 7 2011.48 33 15.08 2866 1426 1.62 / 58.85 2 3
3 13 1590.60 17 15.10 2412 619 2.24 / 59.47 2 4
4 13 1022.68 17 15.18 1679 433 2.67 / 59.90 2 3
5 13 332.88 17 15.31 735 191 2.86 / 60.09 2 3
6 8 0.20 165 15.36 261 661 3.53 / 60.75 2 4
Average= 3.57
(KJ/cycle)

Cycle 15 GMT 18/12/2020 19:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 30 15.32 421 193 0.19 / 53.94 2 3
2 7 2003.56 32 15.08 2850 1375 1.57 / 55.32 2 3
3 13 1467.28 17 15.11 2252 578 2.15 / 55.89 2 3
4 13 1056.48 17 15.16 1720 443 2.59 / 56.34 2 3
5 13 473.48 17 15.27 926 240 2.83 / 56.58 2 3
6 8 0.16 165 15.35 256 648 3.48 / 57.23 2 3
Average= 3.58
(KJ/cycle)

Cycle 14 GMT 8/12/2020 21:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 30 15.32 424 195 0.19 / 50.35 2 3
2 7 2009.28 32 15.10 2868 1386 1.58 / 51.73 2 3
3 13 1587.08 17 15.10 2400 616 2.20 / 52.35 2 3
4 13 1151.60 17 15.15 1834 472 2.67 / 52.82 2 3
5 13 558.20 17 15.27 1044 271 2.94 / 53.09 2 3
6 8 0.00 165 15.36 259 656 3.60 / 53.75 2 3
Average= 3.58
(KJ/cycle)

Cycle 13 GMT 28/11/2020 23:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 30 15.32 416 191 0.19 / 46.80 2 3
2 7 2005.16 32 15.10 2863 1383 1.57 / 48.19 2 3
3 13 1575.24 17 15.11 2401 617 2.19 / 48.80 2 3
4 13 1136.24 17 15.17 1827 471 2.66 / 49.27 2 3
5 13 394.60 17 15.33 820 214 2.88 / 49.49 2 3
6 8 0.20 165 15.38 261 662 3.54 / 50.15 2 6
Average= 3.58
(KJ/cycle)

Cycle 12 GMT 19/11/2020 2: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 30 15.33 416 191 0.19 / 43.26 2 3
2 7 2003.52 33 15.08 2863 1425 1.62 / 44.68 2 3
3 13 1581.76 17 15.10 2401 616 2.23 / 45.30 2 3
4 13 1015.24 17 15.18 1657 428 2.66 / 45.73 2 3
5 13 441.40 17 15.31 881 229 2.89 / 45.96 2 3
6 8 0.20 165 15.36 259 656 3.55 / 46.61 2 4
Average= 3.59
(KJ/cycle)

Cycle 11 GMT 9/11/2020 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 29 15.33 405 180 0.18 / 39.77 2 3
2 7 2004.24 31 15.09 2866 1341 1.52 / 41.11 2 3
3 13 1581.64 18 15.11 2383 648 2.17 / 41.76 2 4
4 13 1018.48 18 15.18 1677 458 2.63 / 42.21 2 3
5 13 305.64 18 15.34 700 193 2.82 / 42.41 2 3
6 8 0.00 165 15.36 260 659 3.48 / 43.07 2 5
Average= 3.59
(KJ/cycle)

Cycle 10 GMT 30/10/2020 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 29 15.34 418 186 0.19 / 36.21 2 3
2 7 2002.16 31 15.10 2862 1340 1.53 / 37.55 2 3
3 13 1726.76 18 15.09 2565 697 2.22 / 38.25 2 3
4 13 993.76 18 15.20 1640 449 2.67 / 38.70 2 3
5 13 425.24 18 15.31 857 236 2.91 / 38.93 2 3
6 8 0.16 165 15.37 258 654 3.56 / 39.59 2 7
Average= 3.60
(KJ/cycle)

Cycle 9 GMT 20/10/2020 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 29 15.34 418 186 0.19 / 32.02 2 3
2 7 2006.60 74 14.94 2827 3125 3.31 / 35.15 2 3
3 13 379.16 18 15.32 796 220 3.53 / 35.37 2 3
4 8 0.08 165 15.37 259 657 4.19 / 36.03 2 3
Average= 3.60
(KJ/cycle)

Cycle 8 GMT 10/10/2020 11: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 29 15.35 424 189 0.19 / 27.82 2 3
2 7 2006.88 74 14.95 2838 3140 3.33 / 30.96 2 3
3 13 360.00 18 15.33 774 214 3.54 / 31.18 2 3
4 8 0.08 165 15.38 261 662 4.20 / 31.84 2 4
Average= 3.54
(KJ/cycle)

Cycle 7 GMT 30/ 9/2020 13:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 15.33 419 186 0.19 / 23.63 2 3
2 7 2008.52 74 14.96 2832 3135 3.32 / 26.77 2 3
3 13 361.20 18 15.34 769 212 3.53 / 26.98 2 3
4 8 0.16 165 15.39 258 655 4.19 / 27.63 2 6
Average= 3.45
(KJ/cycle)

Cycle 6 GMT 20/ 9/2020 16:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 28 15.33 420 180 0.18 / 19.42 2 3
2 10 1028.68 2 15.35 1747 54 0.23 / 19.47 2 3
3 7 2006.32 74 14.97 2836 3142 3.38 / 22.62 2 3
4 13 239.08 18 15.37 603 167 3.54 / 22.78 2 3
5 8 0.00 165 15.38 261 662 4.20 / 23.44 2 5
Average= 3.35
(KJ/cycle)

Cycle 5 GMT 10/ 9/2020 19:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 26 15.35 424 169 0.17 / 14.94 2 3
2 10 1005.20 2 15.33 1719 53 0.22 / 14.99 2 3
3 7 2004.76 74 14.96 2824 3126 3.35 / 18.11 2 4
4 13 249.08 18 15.35 617 170 3.52 / 18.29 2 3
5 8 -0.20 165 15.38 259 657 4.18 / 18.94 2 7
6 14 -0.20 75 15.36 258 297 4.47 / 19.24 2 4
Average= 3.21
(KJ/cycle)

Cycle 4 GMT 31/ 8/2020 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 28 15.35 411 177 0.18 / 11.47 2 3
2 7 1506.64 74 15.12 2253 2521 2.70 / 13.99 2 3
3 13 112.80 18 15.40 427 118 2.82 / 14.11 2 2
4 8 0.16 165 15.39 258 655 3.47 / 14.77 2 3
Average= 2.95
(KJ/cycle)

Cycle 3 GMT 30/ 8/2020 22: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 28 15.35 421 181 0.18 / 7.97 2 3
2 3 1019.36 1 15.40 1775 27 0.21 / 8.00 2 2
3 7 1522.36 74 15.12 2269 2539 2.75 / 10.54 2 3
4 13 56.36 18 15.41 345 96 2.84 / 10.63 2 3
5 8 0.12 165 15.39 261 663 3.51 / 11.30 2 6
Average= 2.82
(KJ/cycle)

Cycle 2 GMT 29/ 8/2020 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 28 15.34 431 185 0.19 / 4.60 2 3
2 7 1525.56 74 15.11 2267 2535 2.72 / 7.14 2 3
3 8 0.08 165 15.40 257 653 3.37 / 7.79 2 4
Average= 2.60
(KJ/cycle)

Cycle 1 GMT 28/ 8/2020 22:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 24 15.53 383 143 0.14 / 1.58 3 3
2 10 1030.12 2 15.36 1753 54 0.20 / 1.63 2 3
3 3 1039.52 1 15.38 1772 27 0.22 / 1.66 2 3
4 7 998.28 74 15.24 1593 1797 2.02 / 3.46 2 3
5 8 0.12 165 15.40 260 661 2.68 / 4.12 2 7
6 14 0.12 75 15.38 258 298 2.98 / 4.42 2 6
Average= 2.21
(KJ/cycle)

Cycle 0 GMT 28/ 8/2020 12:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 79.48 24 15.63 361 135 0.14 / 0.14 3 3
2 7 92.68 74 15.61 370 427 0.56 / 0.56 3 3
3 8 0.24 240 15.59 234 876 1.44 / 1.44 3 7
Average= 1.44
(KJ/cycle)