SIO Argo Site:
Pump Diagnostics Page   



Serial= 3313 WMO= 7902209

Return

←PreviousNext→

Cycle 16 GMT 22/ 4/2025 20:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 27 15.18 434 178 0.18 / 50.96 2 2
2 10 1002.00 2 15.18 1438 44 0.22 / 51.00 2 2
3 7 2009.92 39 14.90 2685 1560 1.78 / 52.57 2 3
4 13 1286.00 18 15.04 1795 486 2.27 / 53.05 2 3
5 13 859.44 18 15.09 1271 345 2.61 / 53.40 2 5
6 13 328.00 18 15.21 664 182 2.79 / 53.58 2 6
7 8 0.00 165 15.24 261 656 3.45 / 54.23 2 11
Average= 3.19
(KJ/cycle)

Cycle 15 GMT 13/ 4/2025 1: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 28 15.18 412 175 0.18 / 47.55 2 2
2 3 980.04 -1 15.48 0 0 0.00 / 47.55 2 2
3 7 2007.32 38 14.90 2700 1529 1.70 / 49.08 2 3
4 13 1396.20 18 15.01 1919 518 2.22 / 49.60 2 3
5 13 874.52 18 15.10 1266 344 2.57 / 49.94 2 4
6 13 352.00 18 15.19 683 187 2.75 / 50.13 2 6
7 8 -0.16 165 15.25 260 654 3.41 / 50.78 2 16
Average= 3.17
(KJ/cycle)

Cycle 14 GMT 3/ 4/2025 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 28 15.17 427 181 0.18 / 44.18 2 2
2 7 2007.04 38 14.90 2686 1521 1.70 / 45.70 2 3
3 13 1352.84 18 15.00 1881 508 2.21 / 46.21 2 3
4 13 830.36 18 15.10 1240 337 2.55 / 46.54 2 4
5 13 310.80 18 15.20 648 177 2.72 / 46.72 2 6
6 8 0.04 165 15.25 260 654 3.38 / 47.38 2 13
Average= 3.16
(KJ/cycle)

Cycle 13 GMT 24/ 3/2025 10:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 28 15.18 416 177 0.18 / 40.82 2 2
2 7 2003.32 38 14.90 2673 1513 1.69 / 42.34 2 3
3 13 1297.96 18 15.02 1812 490 2.18 / 42.83 2 4
4 13 823.56 18 15.11 1199 326 2.51 / 43.15 2 4
5 13 394.12 18 15.18 719 196 2.70 / 43.35 2 5
6 8 0.40 165 15.25 257 647 3.35 / 44.00 2 14
Average= 3.14
(KJ/cycle)

Cycle 12 GMT 14/ 3/2025 15:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 28 15.19 417 177 0.18 / 37.47 2 2
2 7 2008.96 38 14.90 2689 1523 1.70 / 38.99 2 3
3 13 1294.36 18 15.03 1801 487 2.19 / 39.48 2 4
4 13 825.64 18 15.10 1251 340 2.53 / 39.82 2 3
5 13 309.44 18 15.21 647 177 2.70 / 40.00 2 6
6 8 -0.16 165 15.24 258 649 3.35 / 40.65 2 10
Average= 3.13
(KJ/cycle)

Cycle 11 GMT 4/ 3/2025 20:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 28 15.19 408 174 0.17 / 34.13 2 2
2 7 2008.60 38 14.91 2680 1518 1.69 / 35.65 2 3
3 13 1336.16 18 15.02 1870 506 2.20 / 36.15 2 3
4 13 838.24 18 15.11 1202 327 2.52 / 36.48 2 4
5 13 270.44 18 15.21 603 165 2.69 / 36.64 2 5
6 8 0.40 165 15.25 259 652 3.34 / 37.29 2 15
Average= 3.11
(KJ/cycle)

Cycle 10 GMT 23/ 2/2025 2: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 27 15.20 403 165 0.17 / 30.82 2 2
2 7 2007.80 38 14.92 2687 1523 1.69 / 32.35 2 2
3 13 1293.68 18 15.03 1802 488 2.18 / 32.83 2 3
4 13 740.36 18 15.14 1106 301 2.48 / 33.14 2 5
5 13 312.68 18 15.21 642 176 2.65 / 33.31 2 5
6 8 0.16 165 15.26 255 642 3.30 / 33.95 2 13
Average= 3.09
(KJ/cycle)

Cycle 9 GMT 13/ 2/2025 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 26 15.19 422 167 0.17 / 27.42 2 2
2 3 1036.60 1 15.21 1534 23 0.19 / 27.44 2 2
3 7 2011.48 38 14.91 2678 1517 1.71 / 28.96 2 3
4 13 1360.08 18 15.02 1898 513 2.22 / 29.47 2 3
5 13 866.60 18 15.11 1224 333 2.55 / 29.81 2 5
6 13 383.04 18 15.19 721 197 2.75 / 30.00 2 5
7 8 0.08 165 15.26 260 655 3.41 / 30.66 2 11
Average= 3.07
(KJ/cycle)

Cycle 8 GMT 3/ 2/2025 11:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 28 15.18 418 178 0.18 / 24.05 2 2
2 3 917.44 -5 15.47 0 0 0.00 / 24.05 2 2
3 7 2006.68 38 14.92 2676 1517 1.69 / 25.57 2 3
4 13 1321.52 18 15.04 1840 498 2.19 / 26.06 2 3
5 13 852.64 18 15.12 1218 331 2.52 / 26.40 2 4
6 13 434.68 18 15.19 769 210 2.73 / 26.61 2 5
7 8 0.04 165 15.26 257 647 3.38 / 27.25 2 12
Average= 3.03
(KJ/cycle)

Cycle 7 GMT 24/ 1/2025 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 26 15.19 405 160 0.16 / 20.89 2 2
2 7 1807.00 38 14.95 2451 1392 1.55 / 22.28 2 3
3 13 1232.48 18 15.04 1701 460 2.01 / 22.74 2 3
4 13 758.88 18 15.10 1134 308 2.32 / 23.05 2 5
5 13 273.88 18 15.21 604 165 2.49 / 23.21 2 5
6 8 0.12 165 15.24 261 656 3.14 / 23.87 2 13
Average= 2.98
(KJ/cycle)

Cycle 6 GMT 23/ 1/2025 15:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 26 15.19 418 165 0.17 / 17.69 2 2
2 3 1019.16 1 15.25 1522 23 0.19 / 17.71 2 2
3 7 1804.32 38 14.95 2448 1391 1.58 / 19.10 2 3
4 13 1313.96 18 15.01 1859 502 2.08 / 19.61 2 3
5 13 771.84 18 15.13 1149 313 2.39 / 19.92 2 4
6 13 283.32 18 15.22 617 169 2.56 / 20.09 2 4
7 8 0.24 165 15.25 254 639 3.20 / 20.73 2 7
Average= 2.96
(KJ/cycle)

Cycle 5 GMT 22/ 1/2025 13:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 26 15.20 411 162 0.16 / 13.98 2 2
2 7 1805.52 74 14.85 2447 2689 2.85 / 16.67 2 5
3 13 482.24 18 15.18 813 222 3.07 / 16.89 2 5
4 8 0.00 165 15.25 252 634 3.71 / 17.53 2 10
Average= 2.92
(KJ/cycle)

Cycle 4 GMT 21/ 1/2025 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 25 15.21 414 157 0.16 / 10.64 2 2
2 3 1034.76 1 15.26 1393 21 0.18 / 10.66 2 2
3 7 1523.64 74 14.96 2086 2309 2.49 / 12.97 2 5
4 13 424.96 18 15.22 765 210 2.70 / 13.18 2 5
5 8 0.16 165 15.28 253 638 3.34 / 13.82 2 12
Average= 2.76
(KJ/cycle)

Cycle 3 GMT 20/ 1/2025 13:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 23 15.22 419 147 0.15 / 7.24 2 2
2 10 1011.00 2 15.16 1462 44 0.19 / 7.29 2 2
3 7 1507.08 74 14.97 2063 2285 2.48 / 9.57 2 5
4 13 369.88 18 15.24 711 195 2.67 / 9.77 2 5
5 13 15.60 18 15.31 282 78 2.75 / 9.85 2 5
6 8 0.04 165 15.27 253 637 3.39 / 10.48 2 17
Average= 2.62
(KJ/cycle)

Cycle 2 GMT 19/ 1/2025 13:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 31 15.28 411 195 0.19 / 3.95 2 2
2 3 850.12 -3 15.58 0 0 0.00 / 3.95 2 2
3 3 904.92 -2 15.60 0 0 0.00 / 3.95 2 2
4 7 1515.20 74 14.97 2091 2316 2.51 / 6.26 2 5
5 13 371.36 18 15.23 688 189 2.70 / 6.45 2 4
6 8 0.12 165 15.28 256 645 3.35 / 7.10 2 11
Average= 2.37
(KJ/cycle)

Cycle 1 GMT 18/ 1/2025 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 26 15.44 368 148 0.15 / 1.55 2 2
2 7 984.48 74 15.18 1382 1552 1.70 / 3.10 2 6
3 8 -0.12 165 15.35 258 653 2.35 / 3.75 2 16
Average= 1.88
(KJ/cycle)

Cycle 0 GMT 18/ 1/2025 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 25 15.57 369 144 0.14 / 0.14 2 2
2 7 134.88 74 15.54 401 461 0.60 / 0.60 2 3
3 8 0.28 240 15.51 213 793 1.40 / 1.40 2 15
Average= 1.40
(KJ/cycle)