SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 32 | 15.17 | 387 | 188 | 0.19 / 92.34 | 2 | 3 |
2 | 7 | 2010.00 | 39 | 14.93 | 2760 | 1607 | 1.79 / 93.95 | 2 | 6 |
3 | 13 | 1355.72 | 18 | 15.00 | 1994 | 538 | 2.33 / 94.49 | 2 | 8 |
4 | 13 | 844.64 | 18 | 15.08 | 1368 | 371 | 2.70 / 94.86 | 2 | 9 |
5 | 13 | 367.84 | 18 | 15.18 | 749 | 205 | 2.91 / 95.07 | 2 | 8 |
6 | 13 | 36.16 | 18 | 15.25 | 309 | 85 | 2.99 / 95.15 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.21 | 261 | 655 | 3.65 / 95.81 | 2 | 14 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.96 | 32 | 15.17 | 398 | 193 | 0.19 / 88.77 | 2 | 3 |
2 | 7 | 2005.96 | 38 | 14.92 | 2738 | 1552 | 1.75 / 90.32 | 2 | 5 |
3 | 13 | 1342.28 | 18 | 15.00 | 1974 | 533 | 2.28 / 90.86 | 2 | 10 |
4 | 13 | 857.88 | 18 | 15.07 | 1370 | 372 | 2.65 / 91.23 | 2 | 7 |
5 | 13 | 359.64 | 18 | 15.18 | 730 | 199 | 2.85 / 91.43 | 2 | 5 |
6 | 13 | 73.52 | 18 | 15.23 | 353 | 97 | 2.95 / 91.52 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.21 | 252 | 632 | 3.58 / 92.16 | 2 | 12 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 31 | 15.18 | 395 | 186 | 0.19 / 85.09 | 2 | 2 |
2 | 10 | 1004.60 | 2 | 15.24 | 1584 | 48 | 0.23 / 85.14 | 2 | 3 |
3 | 3 | 946.48 | -1 | 15.52 | 0 | 0 | 0.05 / 85.14 | 2 | 3 |
4 | 7 | 2003.36 | 38 | 14.92 | 2746 | 1557 | 1.79 / 86.70 | 2 | 4 |
5 | 13 | 1397.32 | 18 | 14.99 | 2035 | 549 | 2.34 / 87.25 | 2 | 7 |
6 | 13 | 953.96 | 18 | 15.05 | 1496 | 405 | 2.75 / 87.65 | 2 | 7 |
7 | 13 | 354.00 | 18 | 15.19 | 713 | 195 | 2.94 / 87.85 | 2 | 7 |
8 | 13 | 110.76 | 18 | 15.23 | 397 | 109 | 3.05 / 87.96 | 2 | 4 |
9 | 8 | 0.12 | 165 | 15.21 | 248 | 622 | 3.67 / 88.58 | 2 | 11 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 31 | 15.18 | 368 | 173 | 0.17 / 81.48 | 2 | 3 |
2 | 7 | 1973.60 | 38 | 14.94 | 2714 | 1541 | 1.71 / 83.02 | 2 | 4 |
3 | 13 | 1409.20 | 18 | 15.00 | 2049 | 553 | 2.27 / 83.57 | 2 | 9 |
4 | 13 | 871.04 | 18 | 15.07 | 1401 | 380 | 2.65 / 83.95 | 2 | 7 |
5 | 13 | 410.04 | 18 | 15.17 | 791 | 216 | 2.86 / 84.17 | 2 | 8 |
6 | 13 | 153.72 | 18 | 15.22 | 450 | 123 | 2.99 / 84.29 | 2 | 5 |
7 | 8 | 0.00 | 165 | 15.22 | 245 | 615 | 3.60 / 84.91 | 2 | 16 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 31 | 15.18 | 400 | 188 | 0.19 / 77.96 | 2 | 3 |
2 | 3 | 1018.04 | 1 | 15.29 | 1574 | 24 | 0.21 / 77.98 | 2 | 4 |
3 | 7 | 1928.56 | 38 | 14.95 | 2648 | 1504 | 1.72 / 79.49 | 2 | 5 |
4 | 13 | 1337.84 | 18 | 15.01 | 1956 | 528 | 2.25 / 80.02 | 2 | 6 |
5 | 13 | 910.84 | 18 | 15.07 | 1428 | 387 | 2.63 / 80.40 | 2 | 8 |
6 | 13 | 327.36 | 18 | 15.21 | 675 | 185 | 2.82 / 80.59 | 2 | 6 |
7 | 13 | 92.60 | 18 | 15.24 | 365 | 100 | 2.92 / 80.69 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.22 | 245 | 615 | 3.53 / 81.30 | 2 | 13 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 122 | 15.22 | 348 | 646 | 0.65 / 74.12 | 2 | 3 |
2 | 2 | 233.04 | 27 | 15.28 | 494 | 204 | 0.85 / 74.33 | 3 | 3 |
3 | 10 | 1001.72 | 3 | 15.27 | 1550 | 71 | 0.92 / 74.40 | 2 | 3 |
4 | 3 | 1024.52 | 1 | 15.28 | 1582 | 24 | 0.95 / 74.42 | 2 | 3 |
5 | 3 | 1024.88 | 1 | 15.32 | 1600 | 25 | 0.97 / 74.45 | 2 | 3 |
6 | 7 | 2006.32 | 38 | 14.97 | 2722 | 1548 | 2.52 / 75.99 | 2 | 6 |
7 | 13 | 1382.68 | 18 | 15.01 | 1996 | 539 | 3.06 / 76.53 | 2 | 9 |
8 | 13 | 838.28 | 18 | 15.09 | 1335 | 363 | 3.42 / 76.90 | 2 | 9 |
9 | 13 | 352.20 | 18 | 15.19 | 714 | 195 | 3.62 / 77.09 | 2 | 6 |
10 | 13 | 31.32 | 18 | 15.26 | 290 | 80 | 3.69 / 77.17 | 2 | 4 |
11 | 8 | 0.16 | 165 | 15.23 | 239 | 601 | 4.30 / 77.77 | 2 | 15 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 31 | 14.83 | 244 | 112 | 0.11 / 69.23 | 2 | 2 |
2 | 10 | 1113.48 | 8 | 15.19 | 342 | 42 | 0.15 / 69.27 | 2 | 2 |
3 | 10 | 1228.56 | 7 | 15.19 | 396 | 42 | 0.20 / 69.31 | 2 | 2 |
4 | 10 | 1344.20 | 7 | 15.23 | 375 | 40 | 0.24 / 69.35 | 2 | 2 |
5 | 10 | 1451.60 | 7 | 15.16 | 508 | 54 | 0.29 / 69.40 | 2 | 2 |
6 | 10 | 1538.60 | 5 | 15.18 | 533 | 40 | 0.33 / 69.44 | 2 | 2 |
7 | 10 | 1614.64 | 5 | 15.22 | 569 | 43 | 0.37 / 69.49 | 2 | 2 |
8 | 10 | 1678.40 | 4 | 15.22 | 529 | 32 | 0.41 / 69.52 | 2 | 3 |
9 | 10 | 1731.00 | 3 | 15.26 | 495 | 23 | 0.43 / 69.54 | 2 | 2 |
10 | 10 | 1768.32 | 2 | 15.24 | 707 | 22 | 0.45 / 69.56 | 2 | 2 |
11 | 3 | 1787.40 | 22 | 15.28 | 251 | 84 | 0.53 / 69.65 | 2 | 2 |
12 | 3 | 1740.68 | 21 | 15.36 | 232 | 75 | 0.61 / 69.72 | 2 | 2 |
13 | 5 | 1743.68 | 21 | 15.29 | 554 | 178 | 0.79 / 69.90 | 2 | 2 |
14 | 5 | 1666.32 | 19 | 15.38 | 427 | 125 | 0.91 / 70.03 | 2 | 3 |
15 | 5 | 1656.60 | 18 | 15.02 | 1729 | 467 | 1.38 / 70.49 | 2 | 3 |
16 | 5 | 1342.84 | 10 | 15.13 | 1843 | 279 | 1.66 / 70.77 | 2 | 6 |
17 | 7 | 1197.20 | 38 | 15.34 | 1454 | 848 | 2.51 / 71.62 | 2 | 3 |
18 | 13 | 1183.76 | 18 | 15.35 | 1331 | 368 | 2.87 / 71.99 | 2 | 3 |
19 | 13 | 1063.20 | 18 | 15.30 | 1255 | 346 | 3.22 / 72.33 | 2 | 6 |
20 | 13 | 804.32 | 18 | 15.33 | 863 | 238 | 3.46 / 72.57 | 2 | 4 |
21 | 13 | 504.00 | 18 | 15.30 | 731 | 201 | 3.66 / 72.77 | 2 | 4 |
22 | 13 | 233.84 | 18 | 15.32 | 434 | 120 | 3.78 / 72.89 | 2 | 3 |
23 | 13 | 53.24 | 18 | 15.34 | 253 | 70 | 3.85 / 72.96 | 2 | 2 |
24 | 8 | 0.36 | 165 | 15.31 | 204 | 515 | 4.36 / 73.48 | 2 | 4 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.44 | 31 | 15.20 | 421 | 198 | 0.20 / 43.31 | 2 | 3 |
2 | 7 | 1999.72 | 39 | 14.95 | 2762 | 1610 | 1.81 / 44.92 | 2 | 8 |
3 | 13 | 1998.52 | 18 | 14.91 | 2781 | 746 | 2.56 / 45.66 | 2 | 8 |
4 | 13 | 1998.44 | 18 | 14.83 | 2773 | 740 | 3.30 / 46.40 | 2 | 12 |
5 | 13 | 1998.48 | 18 | 14.77 | 2766 | 735 | 4.03 / 47.14 | 2 | 12 |
6 | 13 | 1998.36 | 18 | 14.71 | 2773 | 734 | 4.76 / 47.87 | 2 | 10 |
7 | 13 | 1998.48 | 18 | 14.66 | 2773 | 732 | 5.50 / 48.60 | 2 | 11 |
8 | 13 | 1998.48 | 18 | 14.60 | 2770 | 728 | 6.22 / 49.33 | 2 | 10 |
9 | 13 | 1998.48 | 18 | 14.54 | 2762 | 723 | 6.95 / 50.06 | 2 | 15 |
10 | 13 | 1998.40 | 18 | 14.49 | 2750 | 717 | 7.66 / 50.77 | 2 | 13 |
11 | 13 | 1998.40 | 18 | 14.46 | 2769 | 721 | 8.39 / 51.49 | 2 | 15 |
12 | 13 | 1998.44 | 18 | 14.41 | 2773 | 719 | 9.10 / 52.21 | 2 | 15 |
13 | 13 | 1998.36 | 18 | 14.38 | 2750 | 712 | 9.82 / 52.92 | 2 | 11 |
14 | 13 | 1998.32 | 18 | 14.34 | 2759 | 712 | 10.53 / 53.64 | 2 | 14 |
15 | 13 | 1998.24 | 18 | 14.31 | 2753 | 709 | 11.24 / 54.35 | 2 | 18 |
16 | 13 | 1998.28 | 18 | 14.29 | 2755 | 709 | 11.95 / 55.05 | 2 | 15 |
17 | 13 | 1998.36 | 18 | 14.27 | 2753 | 707 | 12.65 / 55.76 | 2 | 14 |
18 | 13 | 1998.32 | 18 | 14.23 | 2760 | 707 | 13.36 / 56.47 | 3 | 19 |
19 | 13 | 1998.24 | 18 | 14.22 | 2755 | 705 | 14.07 / 57.17 | 4 | 21 |
20 | 13 | 1998.20 | 18 | 14.20 | 2755 | 704 | 14.77 / 57.88 | 3 | 18 |
21 | 13 | 1998.20 | 18 | 14.18 | 2768 | 707 | 15.48 / 58.58 | 4 | 19 |
22 | 13 | 1998.24 | 18 | 14.16 | 2745 | 700 | 16.18 / 59.28 | 4 | 21 |
23 | 13 | 1998.20 | 18 | 14.14 | 2762 | 703 | 16.88 / 59.99 | 5 | 25 |
24 | 13 | 1998.20 | 18 | 14.12 | 2756 | 700 | 17.58 / 60.69 | 5 | 22 |
25 | 13 | 1998.16 | 18 | 14.08 | 2774 | 703 | 18.28 / 61.39 | 7 | 24 |
26 | 13 | 1998.20 | 18 | 14.06 | 2778 | 703 | 18.99 / 62.09 | 4 | 27 |
27 | 13 | 1998.32 | 18 | 14.03 | 2760 | 697 | 19.68 / 62.79 | 6 | 28 |
28 | 13 | 1998.28 | 18 | 14.00 | 2749 | 693 | 20.38 / 63.48 | 9 | 32 |
29 | 13 | 1998.16 | 18 | 13.98 | 2747 | 691 | 21.07 / 64.17 | 14 | 56 |
30 | 13 | 1998.32 | 18 | 13.96 | 2751 | 691 | 21.76 / 64.87 | 39 | 248 |
31 | 13 | 1998.20 | 18 | 13.96 | 2504 | 629 | 22.39 / 65.49 | 248 | 248 |
32 | 13 | 1998.28 | 18 | 14.03 | 2103 | 531 | 22.92 / 66.03 | 248 | 233 |
33 | 13 | 1998.28 | 18 | 14.40 | 459 | 119 | 23.04 / 66.14 | 198 | 150 |
34 | 13 | 1998.28 | 18 | 14.41 | 529 | 137 | 23.17 / 66.28 | 150 | 53 |
35 | 13 | 1998.16 | 18 | 14.43 | 626 | 163 | 23.34 / 66.44 | 67 | 65 |
36 | 13 | 1998.32 | 18 | 14.51 | 410 | 107 | 23.44 / 66.55 | 68 | 77 |
37 | 13 | 1998.28 | 18 | 14.52 | 410 | 107 | 23.55 / 66.66 | 70 | 74 |
38 | 13 | 1998.24 | 18 | 14.57 | 292 | 77 | 23.63 / 66.74 | 72 | 73 |
39 | 13 | 1998.36 | 18 | 14.58 | 409 | 107 | 23.74 / 66.84 | 73 | 73 |
40 | 13 | 1998.36 | 18 | 14.57 | 458 | 120 | 23.86 / 66.96 | 74 | 79 |
41 | 13 | 1998.20 | 18 | 14.61 | 343 | 90 | 23.95 / 67.05 | 75 | 75 |
42 | 13 | 1998.24 | 18 | 14.64 | 264 | 70 | 24.02 / 67.12 | 75 | 76 |
43 | 13 | 1998.28 | 18 | 14.62 | 420 | 111 | 24.13 / 67.23 | 75 | 72 |
44 | 13 | 1998.36 | 18 | 14.66 | 310 | 82 | 24.21 / 67.32 | 72 | 72 |
45 | 13 | 1998.36 | 18 | 14.67 | 335 | 88 | 24.30 / 67.40 | 72 | 72 |
46 | 13 | 1998.36 | 18 | 14.69 | 369 | 98 | 24.39 / 67.50 | 73 | 72 |
47 | 13 | 1998.36 | 18 | 14.69 | 285 | 75 | 24.47 / 67.58 | 73 | 74 |
48 | 13 | 1998.40 | 18 | 14.67 | 434 | 115 | 24.58 / 67.69 | 73 | 74 |
49 | 13 | 1998.28 | 18 | 14.67 | 486 | 128 | 24.71 / 67.82 | 73 | 72 |
50 | 13 | 1998.40 | 18 | 14.67 | 515 | 136 | 24.85 / 67.96 | 73 | 71 |
51 | 13 | 1998.40 | 18 | 14.71 | 406 | 108 | 24.96 / 68.06 | 73 | 72 |
52 | 13 | 1998.36 | 18 | 14.71 | 333 | 88 | 25.04 / 68.15 | 73 | 72 |
53 | 13 | 1998.32 | 18 | 14.74 | 316 | 84 | 25.13 / 68.23 | 73 | 74 |
54 | 13 | 1998.32 | 18 | 14.74 | 297 | 79 | 25.21 / 68.31 | 73 | 72 |
55 | 13 | 1998.32 | 18 | 14.76 | 264 | 70 | 25.28 / 68.38 | 73 | 73 |
56 | 13 | 1998.44 | 18 | 14.76 | 268 | 71 | 25.35 / 68.45 | 72 | 72 |
57 | 13 | 1977.84 | 18 | 14.76 | 324 | 86 | 25.43 / 68.54 | 72 | 73 |
58 | 8 | -0.40 | 165 | 14.82 | 234 | 572 | 26.01 / 69.11 | 91 | 106 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 31 | 15.22 | 418 | 197 | 0.20 / 39.68 | 2 | 3 |
2 | 7 | 2006.04 | 38 | 14.95 | 2774 | 1576 | 1.77 / 41.25 | 2 | 9 |
3 | 13 | 1306.00 | 18 | 15.04 | 1940 | 525 | 2.30 / 41.78 | 2 | 9 |
4 | 13 | 834.52 | 18 | 15.11 | 1363 | 371 | 2.67 / 42.15 | 2 | 11 |
5 | 13 | 350.52 | 18 | 15.20 | 734 | 201 | 2.87 / 42.35 | 2 | 5 |
6 | 13 | 32.96 | 18 | 15.26 | 313 | 86 | 2.96 / 42.43 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.24 | 268 | 674 | 3.63 / 43.11 | 2 | 15 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 31 | 15.23 | 415 | 196 | 0.20 / 36.26 | 2 | 3 |
2 | 7 | 1607.32 | 38 | 15.10 | 2303 | 1321 | 1.52 / 37.58 | 2 | 10 |
3 | 13 | 1308.44 | 18 | 15.10 | 1947 | 529 | 2.05 / 38.11 | 2 | 7 |
4 | 13 | 889.28 | 18 | 15.13 | 1427 | 389 | 2.44 / 38.50 | 2 | 10 |
5 | 13 | 346.28 | 18 | 15.24 | 724 | 199 | 2.63 / 38.70 | 2 | 6 |
6 | 13 | 62.00 | 18 | 15.28 | 351 | 97 | 2.73 / 38.80 | 2 | 5 |
7 | 8 | 0.04 | 165 | 15.26 | 271 | 682 | 3.41 / 39.48 | 2 | 12 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 30 | 15.21 | 427 | 195 | 0.19 / 32.95 | 2 | 2 |
2 | 3 | 1016.28 | 1 | 15.31 | 1613 | 25 | 0.22 / 32.97 | 2 | 3 |
3 | 7 | 1669.84 | 38 | 15.07 | 2363 | 1353 | 1.57 / 34.32 | 2 | 9 |
4 | 13 | 1304.60 | 18 | 15.09 | 1942 | 527 | 2.10 / 34.85 | 2 | 9 |
5 | 13 | 829.72 | 18 | 15.14 | 1352 | 368 | 2.47 / 35.22 | 2 | 9 |
6 | 13 | 280.76 | 18 | 15.25 | 637 | 175 | 2.64 / 35.40 | 2 | 6 |
7 | 8 | 0.00 | 165 | 15.27 | 266 | 670 | 3.31 / 36.07 | 2 | 7 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.24 | 30 | 15.22 | 419 | 191 | 0.19 / 29.31 | 2 | 3 |
2 | 3 | 1051.24 | 1 | 15.27 | 1672 | 26 | 0.22 / 29.34 | 2 | 3 |
3 | 7 | 2002.56 | 38 | 14.98 | 2753 | 1567 | 1.78 / 30.90 | 2 | 10 |
4 | 13 | 1366.88 | 18 | 15.04 | 2012 | 545 | 2.33 / 31.45 | 2 | 7 |
5 | 13 | 793.60 | 18 | 15.14 | 1305 | 356 | 2.68 / 31.80 | 2 | 10 |
6 | 13 | 322.24 | 18 | 15.24 | 695 | 191 | 2.87 / 32.00 | 2 | 8 |
7 | 13 | 21.88 | 18 | 15.28 | 297 | 82 | 2.96 / 32.08 | 2 | 4 |
8 | 8 | 0.12 | 165 | 15.26 | 268 | 675 | 3.63 / 32.75 | 2 | 17 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 30 | 15.26 | 398 | 182 | 0.18 / 24.99 | 2 | 3 |
2 | 7 | 2003.32 | 74 | 14.86 | 2749 | 3023 | 3.21 / 28.01 | 2 | 14 |
3 | 13 | 579.52 | 18 | 15.18 | 1048 | 286 | 3.49 / 28.30 | 2 | 14 |
4 | 13 | 140.16 | 18 | 15.27 | 459 | 126 | 3.62 / 28.42 | 2 | 5 |
5 | 8 | -0.04 | 165 | 15.26 | 277 | 697 | 4.32 / 29.12 | 2 | 12 |
Average= | 3.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 29 | 15.25 | 422 | 187 | 0.19 / 21.81 | 2 | 2 |
2 | 7 | 1213.20 | 74 | 15.13 | 1801 | 2016 | 2.20 / 23.82 | 2 | 8 |
3 | 13 | 315.52 | 18 | 15.29 | 690 | 190 | 2.39 / 24.01 | 2 | 8 |
4 | 13 | 98.88 | 18 | 15.33 | 403 | 111 | 2.50 / 24.12 | 2 | 5 |
5 | 8 | 0.08 | 165 | 15.30 | 270 | 682 | 3.19 / 24.80 | 2 | 10 |
Average= | 3.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 29 | 15.25 | 428 | 189 | 0.19 / 18.33 | 2 | 2 |
2 | 7 | 1406.80 | 74 | 15.07 | 2025 | 2258 | 2.45 / 20.59 | 2 | 14 |
3 | 13 | 410.16 | 18 | 15.27 | 815 | 224 | 2.67 / 20.81 | 2 | 7 |
4 | 13 | 81.44 | 18 | 15.31 | 387 | 107 | 2.78 / 20.92 | 2 | 5 |
5 | 8 | 0.16 | 165 | 15.29 | 277 | 699 | 3.48 / 21.62 | 2 | 11 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 29 | 15.24 | 427 | 189 | 0.19 / 14.82 | 2 | 3 |
2 | 7 | 1447.24 | 74 | 15.06 | 2076 | 2314 | 2.50 / 17.13 | 2 | 11 |
3 | 13 | 364.04 | 18 | 15.28 | 753 | 207 | 2.71 / 17.34 | 2 | 7 |
4 | 13 | 93.72 | 18 | 15.31 | 400 | 110 | 2.82 / 17.45 | 2 | 4 |
5 | 8 | 0.08 | 165 | 15.29 | 275 | 694 | 3.51 / 18.14 | 2 | 11 |
Average= | 3.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 29 | 15.24 | 412 | 182 | 0.18 / 11.24 | 2 | 3 |
2 | 7 | 1499.72 | 74 | 15.03 | 2142 | 2382 | 2.56 / 13.62 | 2 | 17 |
3 | 13 | 366.36 | 18 | 15.26 | 765 | 210 | 2.77 / 13.83 | 2 | 9 |
4 | 13 | 96.44 | 18 | 15.30 | 401 | 110 | 2.89 / 13.94 | 2 | 5 |
5 | 8 | 0.12 | 165 | 15.28 | 272 | 686 | 3.57 / 14.63 | 2 | 15 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 29 | 15.23 | 392 | 173 | 0.17 / 7.73 | 2 | 2 |
2 | 7 | 1441.80 | 74 | 15.06 | 2076 | 2314 | 2.49 / 10.04 | 2 | 15 |
3 | 13 | 424.72 | 18 | 15.26 | 831 | 228 | 2.71 / 10.27 | 2 | 9 |
4 | 13 | 86.88 | 18 | 15.31 | 386 | 106 | 2.82 / 10.38 | 2 | 5 |
5 | 8 | 0.04 | 165 | 15.29 | 269 | 679 | 3.50 / 11.06 | 2 | 17 |
Average= | 2.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 32 | 15.29 | 410 | 201 | 0.20 / 4.20 | 2 | 2 |
2 | 3 | 885.56 | -2 | 15.61 | 0 | 0 | 0.00 / 4.20 | 2 | 2 |
3 | 7 | 1496.80 | 74 | 15.04 | 2137 | 2378 | 2.58 / 6.57 | 2 | 9 |
4 | 13 | 376.88 | 18 | 15.26 | 760 | 209 | 2.79 / 6.78 | 2 | 8 |
5 | 13 | 92.00 | 18 | 15.30 | 388 | 107 | 2.89 / 6.89 | 2 | 5 |
6 | 8 | 0.12 | 165 | 15.28 | 265 | 668 | 3.56 / 7.56 | 2 | 11 |
Average= | 2.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 27 | 15.45 | 362 | 151 | 0.15 / 1.58 | 3 | 3 |
2 | 10 | 1034.12 | 2 | 15.33 | 1622 | 50 | 0.20 / 1.63 | 2 | 6 |
3 | 7 | 972.72 | 74 | 15.21 | 1493 | 1680 | 1.88 / 3.31 | 2 | 14 |
4 | 8 | 0.04 | 165 | 15.35 | 269 | 681 | 2.56 / 4.00 | 2 | 23 |
Average= | 2.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 92.88 | 27 | 15.60 | 366 | 154 | 0.15 / 0.15 | 2 | 3 |
2 | 7 | 110.52 | 75 | 15.58 | 377 | 441 | 0.59 / 0.59 | 2 | 3 |
3 | 8 | 0.28 | 240 | 15.52 | 225 | 838 | 1.43 / 1.43 | 3 | 6 |
Average= | 1.43 (KJ/cycle) |