SIO Argo Site:
Pump Diagnostics Page   



Serial= 6117 WMO= 7901069

Return

←PreviousNext→

Cycle 11 GMT 4/12/2024 20:56: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 74.4 11 142 14.87 439 927 0.93 / 147.47 3 19
2 6 5002.7 697 62 14.41 3331 2976 3.90 / 150.45 3 29
3 3 4530.9 938 1 14.76 3029 45 3.95 / 150.49 3 25
4 7 4524.2 963 80 14.57 3056 3562 7.51 / 154.06 3 31
5 13 3735.8 1155 80 14.58 2504 2921 10.43 / 156.98 3 36
6 13 2575.7 1413 80 14.70 1957 2301 12.73 / 159.28 3 37
7 13 1981.9 1521 80 14.73 1632 1923 14.65 / 161.20 3 36
8 13 985.7 1683 80 14.90 1028 1225 15.88 / 162.43 3 35
9 13 943.9 1689 80 14.83 1003 1190 17.07 / 163.62 3 35
10 13 728.3 1712 80 14.81 864 1024 18.09 / 164.64 3 62
11 14 0.2 1788 35 14.94 397 208 18.30 / 164.85 3 106
12 14 0.1 1789 65 14.91 385 373 18.67 / 165.22 20 249
Average= 13.77
(KJ/cycle)

Cycle 10 GMT 2/12/2024 19:17: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.4 9 142 14.88 428 904 0.90 / 128.82 3 20
2 6 5007.9 714 62 14.41 3333 2978 3.88 / 131.80 3 29
3 7 4503.1 963 80 14.58 3000 3499 7.38 / 135.30 3 32
4 13 3697.1 1161 80 14.59 2500 2918 10.30 / 138.21 3 36
5 13 2697.1 1377 80 14.67 2052 2408 12.71 / 140.62 3 38
6 13 1957.7 1509 80 14.75 1603 1892 14.60 / 142.51 3 36
7 13 1011.7 1659 80 14.89 1035 1233 15.83 / 143.75 3 36
8 13 971.1 1665 80 14.82 1014 1202 17.03 / 144.95 3 36
9 13 723.6 1691 80 14.82 861 1021 18.05 / 145.97 3 65
10 14 0.5 1767 35 14.94 396 207 18.26 / 146.18 3 114
11 14 0.4 1769 65 14.92 380 369 18.63 / 146.55 15 249
Average= 13.32
(KJ/cycle)

Cycle 9 GMT 30/11/2024 17:41: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 75.2 11 142 14.88 445 940 0.94 / 110.27 3 19
2 6 5007.4 706 61 14.43 3332 2933 3.87 / 113.20 3 29
3 7 4527.6 963 80 14.60 2968 3467 7.34 / 116.67 3 30
4 13 3740.3 1155 80 14.57 2553 2976 10.32 / 119.64 3 35
5 13 2572.7 1419 80 14.71 1954 2299 12.62 / 121.94 3 38
6 13 1976.6 1533 80 14.74 1629 1921 14.54 / 123.86 3 36
7 13 1086.0 1677 80 14.88 1096 1305 15.84 / 125.17 3 36
8 13 862.7 1707 80 14.86 951 1131 16.97 / 126.30 3 36
9 13 738.4 1721 80 14.82 874 1036 18.01 / 127.34 3 58
10 14 0.6 1798 33 14.94 397 196 18.20 / 127.53 3 100
11 14 0.5 1800 67 14.92 384 384 18.59 / 127.92 13 249
Average= 12.79
(KJ/cycle)

Cycle 8 GMT 28/11/2024 15:43: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 73.3 11 143 14.92 442 943 0.94 / 91.51 3 20
2 6 5006.6 722 61 14.43 3340 2940 3.88 / 94.45 3 26
3 7 4493.0 963 80 14.59 3028 3534 7.42 / 97.99 3 30
4 13 3756.1 1137 80 14.57 2548 2970 10.39 / 100.96 3 36
5 13 2639.2 1383 80 14.70 2010 2364 12.75 / 103.32 3 37
6 13 1975.7 1503 80 14.74 1634 1927 14.68 / 105.25 3 37
7 13 1010.9 1659 80 14.90 1051 1253 15.93 / 106.50 3 36
8 13 972.6 1665 80 14.83 1025 1216 17.15 / 107.72 3 36
9 13 721.2 1691 80 14.82 865 1026 18.17 / 108.74 3 57
10 14 0.6 1769 35 14.94 406 212 18.38 / 108.96 3 106
11 14 0.6 1770 65 14.92 384 372 18.76 / 109.33 20 249
Average= 12.15
(KJ/cycle)

Cycle 7 GMT 26/11/2024 13:58: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.8 9 165 14.89 427 1049 1.05 / 76.18 3 20
2 6 4506.1 670 96 14.42 3063 4240 5.29 / 80.42 3 33
3 3 3655.9 911 8 14.74 2496 294 5.58 / 80.71 3 30
4 7 3370.2 723 80 14.73 2361 2782 8.37 / 83.50 3 36
5 13 2501.8 945 80 14.75 1922 2268 10.63 / 85.76 3 38
6 13 1976.2 1047 80 14.76 1637 1933 12.57 / 87.70 3 37
7 13 979.1 1209 80 14.92 1034 1234 13.80 / 88.93 3 36
8 13 732.1 1241 80 14.90 879 1048 14.85 / 89.98 3 35
9 14 0.4 1332 101 14.98 392 593 15.44 / 90.57 3 103
Average= 11.32
(KJ/cycle)

Cycle 6 GMT 24/11/2024 20:22: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.4 11 159 14.89 448 1061 1.06 / 59.20 3 19
2 6 4508.4 633 96 14.41 3067 4243 5.30 / 63.45 3 31
3 3 3726.0 874 12 14.73 2534 448 5.75 / 63.89 3 30
4 7 3423.7 723 80 14.73 2397 2825 8.58 / 66.72 3 35
5 13 2644.3 915 80 14.72 2029 2389 10.97 / 69.11 3 38
6 13 1973.8 1041 80 14.76 1648 1946 12.91 / 71.05 3 36
7 13 986.5 1203 80 14.91 1043 1244 14.16 / 72.30 3 36
8 13 945.0 1209 80 14.84 1016 1206 15.36 / 73.51 3 34
9 13 731.1 1232 80 14.83 879 1043 16.40 / 74.55 3 41
10 14 0.6 1309 39 14.95 401 234 16.64 / 74.78 3 104
11 14 0.8 1310 61 14.94 382 348 16.99 / 75.13 23 249
Average= 10.73
(KJ/cycle)

Cycle 5 GMT 23/11/2024 3:48: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.5 10 181 14.88 441 1188 1.19 / 43.93 3 20
2 6 4004.2 588 64 14.55 2724 2537 3.72 / 46.47 3 27
3 3 3571.0 829 3 14.89 2515 112 3.84 / 46.58 3 28
4 3 3539.0 0 2 14.93 2553 76 3.91 / 46.65 3 28
5 7 3520.2 723 80 14.71 2490 2930 6.84 / 49.58 3 34
6 13 2658.0 945 80 14.72 2035 2396 9.24 / 51.98 3 37
7 13 1982.2 1077 80 14.76 1662 1962 11.20 / 53.94 3 35
8 13 1063.1 1233 80 14.90 1096 1306 12.51 / 55.25 3 36
9 13 985.3 1245 80 14.84 1047 1243 13.75 / 56.49 3 35
10 13 746.7 1272 80 14.83 890 1056 14.81 / 57.55 3 36
11 14 0.2 1353 43 14.96 408 262 15.07 / 57.81 3 112
12 14 0.3 1354 57 14.94 391 333 15.40 / 58.14 19 249
Average= 9.69
(KJ/cycle)

Cycle 4 GMT 21/11/2024 11:15: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.9 9 167 15.01 436 1093 1.09 / 27.98 3 20
2 6 4005.3 551 64 14.57 2732 2548 3.64 / 30.52 3 31
3 3 3778.2 792 15 14.73 2636 582 4.22 / 31.11 3 30
4 3 3569.2 1032 3 14.92 2551 114 4.34 / 31.22 3 28
5 7 3543.2 482 80 14.71 2501 2943 7.28 / 34.16 3 35
6 13 2693.3 686 80 14.71 2092 2462 9.74 / 36.63 3 37
7 13 1981.7 824 80 14.76 1674 1977 11.72 / 38.60 3 35
8 13 991.4 992 80 14.92 1058 1263 12.98 / 39.87 3 36
9 13 948.7 998 80 14.85 1026 1219 14.20 / 41.08 3 34
10 13 732.5 1021 80 14.84 885 1051 15.25 / 42.14 3 35
11 14 0.6 1099 45 14.95 414 279 15.53 / 42.41 3 107
12 14 0.7 1100 55 14.93 398 327 15.86 / 42.74 14 249
Average= 8.55
(KJ/cycle)

Cycle 3 GMT 19/11/2024 19:33: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.1 12 349 14.95 453 2364 2.36 / 23.15 3 18
2 6 1008.6 197 60 14.88 1053 940 3.30 / 24.09 3 24
3 3 716.6 318 5 15.05 890 67 3.37 / 24.15 3 21
4 7 519.5 1042 80 15.19 749 910 4.28 / 25.06 3 26
5 13 488.8 1048 80 15.12 729 882 5.16 / 25.95 3 25
6 14 0.0 1121 157 15.09 396 938 6.10 / 26.88 3 105
Average= 6.72
(KJ/cycle)

Cycle 2 GMT 19/11/2024 0:43: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.4 12 342 14.95 464 2372 2.37 / 16.77 3 20
2 6 1010.3 184 60 14.86 1075 958 3.33 / 17.73 3 25
3 3 784.4 305 9 15.03 952 129 3.46 / 17.86 3 23
4 7 587.3 1029 80 15.17 810 983 4.44 / 18.84 3 25
5 13 557.3 1035 80 15.10 783 946 5.39 / 19.79 3 25
6 14 0.2 1117 161 15.07 411 997 6.39 / 20.78 3 106
Average= 6.93
(KJ/cycle)

Cycle 1 GMT 18/11/2024 5:59: 3

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.3 13 284 14.81 504 2120 2.12 / 9.03 3 21
2 6 1015.3 137 60 14.83 1122 998 3.12 / 10.03 3 26
3 3 1437.4 259 43 14.91 1409 903 4.02 / 10.93 3 27
4 3 1163.2 380 28 14.97 1262 529 4.55 / 11.46 3 27
5 3 832.3 501 11 15.06 1072 178 4.73 / 11.64 3 26
6 7 464.6 984 80 15.17 782 949 5.68 / 12.58 3 28
7 13 435.7 990 80 15.10 721 871 6.55 / 13.46 3 27
8 14 0.5 1054 150 15.07 417 943 7.49 / 14.40 3 102
Average= 7.20
(KJ/cycle)

Cycle 0 GMT 17/11/2024 12:17: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 151.9 44279 407 15.15 552 3404 3.40 / 3.40 3 19
2 7 234.1 44281 80 15.00 583 700 4.10 / 4.10 3 16
3 13 265.6 44287 80 14.95 605 724 4.83 / 4.83 3 21
4 13 264.7 44305 80 14.90 614 732 5.56 / 5.56 3 22
5 13 183.7 44323 80 14.87 565 672 6.23 / 6.23 3 29
6 14 0.7 44351 45 14.90 463 310 6.54 / 6.54 3 105
7 14 0.6 44352 55 14.88 447 366 6.91 / 6.91 17 249
Average= 6.91