SIO Argo Site:
Pump Diagnostics Page   



Serial= 3182 WMO= 7900811

Return

←PreviousNext→

Cycle 71 GMT 15/11/2024 2:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 18 15.14 544 148 0.15 / 250.05 2 21
2 3 1356.64 -2 15.46 0 0 0.00 / 250.05 2 21
3 3 1424.92 1 15.04 2275 34 0.18 / 250.09 2 15
4 7 2003.84 38 14.84 2872 1620 1.80 / 251.71 2 14
5 13 1303.12 18 14.94 2049 551 2.35 / 252.26 2 18
6 13 787.88 18 15.04 1401 379 2.73 / 252.64 2 20
7 13 212.60 10 15.19 666 101 2.83 / 252.74 2 22
8 8 0.08 165 15.20 356 893 3.73 / 253.63 2 8
Average= 3.52
(KJ/cycle)

Cycle 70 GMT 5/11/2024 7:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 18 15.15 526 143 0.14 / 246.28 2 20
2 3 1380.08 -1 15.47 0 0 0.00 / 246.28 2 20
3 3 1418.04 1 15.07 2287 34 0.18 / 246.32 2 13
4 7 2004.16 38 14.85 2870 1620 1.80 / 247.94 2 13
5 13 1182.92 18 14.99 1894 511 2.31 / 248.45 2 17
6 13 590.68 18 15.12 1142 311 2.62 / 248.76 2 21
7 13 191.08 9 15.21 636 87 2.71 / 248.85 2 22
8 8 0.32 165 15.21 356 893 3.60 / 249.74 2 6
9 14 0.32 30 15.19 357 163 3.76 / 249.90 2 5
Average= 3.52
(KJ/cycle)

Cycle 69 GMT 26/10/2024 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 18 15.14 537 146 0.15 / 242.65 2 19
2 7 2011.56 38 14.86 2871 1621 1.77 / 244.28 2 12
3 13 1275.16 18 14.99 1996 539 2.31 / 244.81 2 16
4 13 742.76 18 15.08 1339 363 2.67 / 245.18 2 20
5 13 178.44 9 15.21 618 85 2.75 / 245.26 2 21
6 8 0.08 165 15.22 350 879 3.63 / 246.14 2 9
Average= 3.52
(KJ/cycle)

Cycle 68 GMT 16/10/2024 17:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 18 15.15 525 143 0.14 / 238.98 2 19
2 7 2003.92 38 14.84 2852 1608 1.75 / 240.59 2 13
3 13 1300.12 18 14.97 2028 546 2.30 / 241.14 2 17
4 13 816.24 18 15.05 1422 385 2.68 / 241.52 2 18
5 13 225.60 10 15.20 678 103 2.79 / 241.63 2 21
6 8 -0.12 165 15.20 351 880 3.67 / 242.51 2 7
Average= 3.51
(KJ/cycle)

Cycle 67 GMT 6/10/2024 22: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 18 15.14 535 146 0.15 / 235.27 2 18
2 7 2008.32 38 14.87 2870 1622 1.77 / 236.89 2 14
3 13 1339.60 18 14.97 2090 563 2.33 / 237.46 2 16
4 13 840.76 18 15.05 1457 395 2.73 / 237.85 2 18
5 13 251.76 11 15.20 710 119 2.84 / 237.97 2 21
6 8 0.20 165 15.22 347 871 3.72 / 238.84 2 9
Average= 3.51
(KJ/cycle)

Cycle 66 GMT 27/ 9/2024 3: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 18 15.15 537 146 0.15 / 231.58 2 19
2 7 2002.64 38 14.86 2865 1618 1.76 / 233.20 2 14
3 13 1344.00 18 14.96 2090 563 2.33 / 233.76 2 17
4 13 756.40 18 15.07 1359 369 2.70 / 234.13 2 19
5 13 259.24 11 15.19 716 120 2.82 / 234.25 2 21
6 8 0.00 165 15.20 348 873 3.69 / 235.13 2 6
Average= 3.51
(KJ/cycle)

Cycle 65 GMT 17/ 9/2024 8: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 18 15.14 544 148 0.15 / 227.91 2 19
2 7 2010.92 38 14.87 2877 1626 1.77 / 229.54 2 14
3 13 1307.20 18 14.98 2042 551 2.32 / 230.09 2 16
4 13 771.72 18 15.07 1373 372 2.70 / 230.46 2 19
5 13 235.28 10 15.21 687 104 2.80 / 230.56 2 21
6 8 0.24 165 15.22 348 874 3.68 / 231.44 2 6
Average= 3.51
(KJ/cycle)

Cycle 64 GMT 7/ 9/2024 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 18 15.15 538 147 0.15 / 224.11 2 19
2 7 2004.72 38 14.88 2868 1622 1.77 / 225.73 2 13
3 13 1444.00 18 14.95 2222 598 2.37 / 226.33 2 18
4 13 811.76 18 15.07 1430 388 2.75 / 226.72 2 18
5 13 321.00 13 15.19 799 158 2.91 / 226.88 2 22
6 8 -0.16 165 15.21 353 886 3.80 / 227.76 2 7
Average= 3.50
(KJ/cycle)

Cycle 63 GMT 28/ 8/2024 17:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 18 15.15 544 148 0.15 / 220.41 2 20
2 7 2008.12 38 14.85 2856 1612 1.76 / 222.02 2 13
3 13 1305.12 18 14.97 2044 551 2.31 / 222.58 2 16
4 13 729.72 18 15.06 1319 358 2.67 / 222.93 2 19
5 13 321.20 13 15.16 803 158 2.83 / 223.09 2 22
6 8 0.52 165 15.20 348 873 3.70 / 223.96 2 6
Average= 3.50
(KJ/cycle)

Cycle 62 GMT 18/ 8/2024 22:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 18 15.13 534 145 0.15 / 216.57 2 19
2 7 2007.56 38 14.88 2866 1621 1.77 / 218.19 2 14
3 13 1280.80 18 15.00 1990 537 2.30 / 218.72 2 16
4 13 719.88 18 15.10 1313 357 2.66 / 219.08 2 19
5 13 181.24 9 15.24 620 85 2.75 / 219.17 2 21
6 13 92.24 6 15.26 495 45 2.79 / 219.21 2 20
7 8 -0.36 165 15.23 355 892 3.68 / 220.10 2 7
8 14 -0.36 30 15.21 355 162 3.84 / 220.26 2 4
Average= 3.50
(KJ/cycle)

Cycle 61 GMT 9/ 8/2024 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 17 15.14 523 135 0.13 / 212.63 2 20
2 7 2004.24 38 14.87 2862 1617 1.75 / 214.24 2 13
3 13 1337.92 18 14.98 2073 559 2.31 / 214.80 2 17
4 13 695.80 18 15.10 1281 348 2.66 / 215.15 2 19
5 13 209.20 10 15.23 660 101 2.76 / 215.25 2 23
6 13 20.76 5 15.28 364 28 2.79 / 215.28 2 3
7 13 18.64 15 15.28 374 86 2.87 / 215.36 2 3
8 8 0.36 165 15.22 356 894 3.77 / 216.26 2 5
9 14 0.36 30 15.19 356 162 3.93 / 216.42 2 6
Average= 3.49
(KJ/cycle)

Cycle 60 GMT 30/ 7/2024 8: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 17 15.15 544 140 0.14 / 208.72 2 20
2 7 2004.64 39 14.86 2873 1665 1.81 / 210.38 2 14
3 13 1336.56 18 14.98 2083 562 2.37 / 210.94 2 16
4 13 750.76 18 15.09 1355 368 2.73 / 211.31 2 19
5 13 204.92 10 15.21 660 100 2.84 / 211.41 2 22
6 13 54.96 5 15.27 421 32 2.87 / 211.44 2 11
7 8 0.12 165 15.22 353 886 3.75 / 212.33 2 7
8 14 0.12 30 15.19 354 161 3.92 / 212.49 2 7
Average= 3.48
(KJ/cycle)

Cycle 59 GMT 20/ 7/2024 13: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 17 15.15 544 140 0.14 / 204.77 2 20
2 7 2010.12 38 14.87 2887 1631 1.77 / 206.40 2 12
3 13 1357.92 18 14.96 2117 570 2.34 / 206.97 2 16
4 13 769.72 18 15.07 1374 373 2.71 / 207.35 2 19
5 13 236.76 10 15.20 693 105 2.82 / 207.45 2 22
6 13 65.80 6 15.25 443 41 2.86 / 207.49 2 15
7 13 53.96 5 15.25 417 32 2.89 / 207.52 2 7
8 8 0.32 165 15.20 355 890 3.78 / 208.42 2 8
9 14 0.32 30 15.19 353 161 3.94 / 208.58 2 5
Average= 3.48
(KJ/cycle)

Cycle 58 GMT 10/ 7/2024 17:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 17 15.17 532 137 0.14 / 200.94 2 18
2 7 2005.92 38 14.87 2865 1619 1.76 / 202.56 2 13
3 13 1315.00 18 14.99 2046 552 2.31 / 203.11 2 17
4 13 691.24 18 15.10 1279 348 2.66 / 203.46 2 20
5 13 250.80 11 15.21 708 118 2.77 / 203.58 2 22
6 8 0.00 165 15.23 356 895 3.67 / 204.47 2 5
7 14 0.00 30 15.20 356 162 3.83 / 204.63 2 6
Average= 3.47
(KJ/cycle)

Cycle 57 GMT 30/ 6/2024 19:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 17 15.14 544 140 0.14 / 197.28 2 18
2 7 2003.36 38 14.86 2861 1616 1.76 / 198.89 2 13
3 13 1234.64 18 15.00 1958 529 2.28 / 199.42 2 16
4 13 753.04 18 15.08 1359 369 2.65 / 199.79 2 19
5 13 251.32 11 15.20 712 119 2.77 / 199.91 2 21
6 8 0.04 165 15.22 355 892 3.66 / 200.80 2 4
Average= 3.46
(KJ/cycle)

Cycle 56 GMT 20/ 6/2024 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 15 15.17 532 121 0.12 / 193.29 2 18
2 10 1440.24 2 15.00 2292 69 0.19 / 193.36 2 13
3 3 1427.32 1 15.01 2293 34 0.22 / 193.40 2 14
4 3 1386.76 -1 15.50 0 0 0.10 / 193.40 2 14
5 7 2007.32 38 14.86 2878 1625 1.85 / 195.02 2 13
6 13 1383.64 18 14.96 2148 578 2.43 / 195.60 2 17
7 13 696.96 18 15.09 1289 350 2.78 / 195.95 2 19
8 13 211.44 10 15.21 657 100 2.88 / 196.05 2 21
9 13 53.52 5 15.26 412 31 2.91 / 196.08 2 6
10 8 0.24 165 15.22 356 894 3.80 / 196.98 2 5
11 14 0.24 30 15.19 356 162 3.97 / 197.14 2 7
Average= 3.46
(KJ/cycle)

Cycle 55 GMT 11/ 6/2024 2:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 23 15.16 541 189 0.19 / 189.61 2 18
2 3 1202.12 -10 15.48 0 0 0.00 / 189.61 2 18
3 3 1227.84 -9 15.51 0 0 0.00 / 189.61 2 18
4 7 1992.28 38 14.87 2855 1613 1.80 / 191.22 2 13
5 13 1258.40 18 14.99 1991 537 2.34 / 191.76 2 17
6 13 677.52 18 15.11 1263 344 2.68 / 192.11 2 19
7 13 177.64 9 15.23 613 84 2.77 / 192.19 2 21
8 13 18.08 18 15.27 371 102 2.87 / 192.29 2 4
9 8 0.00 165 15.22 351 881 3.75 / 193.17 2 10
Average= 3.45
(KJ/cycle)

Cycle 54 GMT 1/ 6/2024 3:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 23 15.18 534 186 0.19 / 185.86 2 18
2 7 2004.80 39 14.87 2881 1671 1.86 / 187.53 2 12
3 13 1252.08 18 15.00 1983 535 2.39 / 188.06 2 17
4 13 718.68 18 15.10 1324 360 2.75 / 188.42 2 19
5 13 222.36 10 15.21 676 103 2.86 / 188.53 2 22
6 8 0.24 165 15.22 357 897 3.75 / 189.42 2 8
Average= 3.44
(KJ/cycle)

Cycle 53 GMT 22/ 5/2024 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 23 15.17 528 184 0.18 / 182.40 2 19
2 7 1759.92 38 14.98 2571 1464 1.65 / 183.87 2 16
3 13 1030.04 18 15.08 1702 462 2.11 / 184.33 2 17
4 13 491.40 18 15.18 1020 279 2.39 / 184.61 2 21
5 8 0.32 165 15.26 357 899 3.29 / 185.51 2 11
6 14 0.32 30 15.23 357 163 3.45 / 185.67 2 7
Average= 3.44
(KJ/cycle)

Cycle 52 GMT 12/ 5/2024 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 23 15.16 537 187 0.19 / 178.66 2 17
2 7 2003.56 38 14.88 2857 1615 1.80 / 180.28 2 13
3 13 1295.48 18 14.99 2031 548 2.35 / 180.83 2 16
4 13 755.68 18 15.09 1357 369 2.72 / 181.20 2 19
5 13 213.92 10 15.23 665 101 2.82 / 181.30 2 21
6 13 48.96 5 15.27 410 31 2.85 / 181.33 2 8
7 8 0.12 165 15.23 355 892 3.74 / 182.22 2 9
Average= 3.44
(KJ/cycle)

Cycle 51 GMT 2/ 5/2024 11:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 23 15.16 534 186 0.19 / 174.76 2 18
2 7 2002.60 38 14.87 2881 1628 1.81 / 176.39 2 17
3 13 1307.16 18 14.99 2044 552 2.37 / 176.94 2 17
4 13 775.08 18 15.09 1392 378 2.74 / 177.32 2 19
5 13 235.92 10 15.22 692 105 2.85 / 177.42 2 22
6 8 -0.04 165 15.22 355 892 3.74 / 178.31 2 4
7 14 -0.04 30 15.20 354 161 3.90 / 178.48 2 8
Average= 3.43
(KJ/cycle)

Cycle 50 GMT 22/ 4/2024 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 23 15.20 533 186 0.19 / 171.05 2 18
2 7 2003.36 39 14.87 2875 1667 1.85 / 172.72 2 13
3 13 1233.72 18 15.01 1958 529 2.38 / 173.25 2 16
4 13 716.96 18 15.10 1313 357 2.74 / 173.60 2 18
5 13 182.88 9 15.22 624 85 2.82 / 173.69 2 21
6 8 0.00 165 15.22 353 886 3.71 / 174.57 2 7
Average= 3.42
(KJ/cycle)

Cycle 49 GMT 12/ 4/2024 15:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 22 15.17 538 180 0.18 / 167.86 2 19
2 7 1716.60 39 14.99 2534 1481 1.66 / 169.34 2 18
3 13 891.48 18 15.13 1536 418 2.08 / 169.76 2 18
4 13 394.40 15 15.23 900 206 2.28 / 169.97 2 21
5 8 0.00 165 15.28 355 895 3.18 / 170.86 2 10
Average= 3.42
(KJ/cycle)

Cycle 48 GMT 2/ 4/2024 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 22 15.17 533 178 0.18 / 164.15 2 18
2 7 2011.00 38 14.89 2877 1628 1.81 / 165.78 2 14
3 13 1307.24 18 15.00 2055 555 2.36 / 166.33 2 19
4 13 716.00 18 15.11 1319 359 2.72 / 166.69 2 20
5 13 225.56 10 15.24 684 104 2.82 / 166.80 2 22
6 8 0.28 165 15.24 353 888 3.71 / 167.68 2 6
Average= 3.42
(KJ/cycle)

Cycle 47 GMT 23/ 3/2024 18:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 22 15.19 536 179 0.18 / 160.63 2 19
2 7 1890.64 39 14.90 2739 1592 1.77 / 162.22 2 16
3 13 1164.96 18 15.04 1878 508 2.28 / 162.73 2 17
4 13 573.20 18 15.14 1129 308 2.59 / 163.03 2 20
5 13 80.72 6 15.26 472 43 2.63 / 163.08 2 20
6 8 0.24 165 15.24 356 895 3.53 / 163.97 2 4
Average= 3.42
(KJ/cycle)

Cycle 46 GMT 13/ 3/2024 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 22 15.17 544 182 0.18 / 156.99 2 19
2 7 1871.72 38 14.94 2725 1547 1.73 / 158.54 2 14
3 13 1129.80 18 15.06 1831 496 2.22 / 159.03 2 17
4 13 575.24 18 15.17 1132 309 2.53 / 159.34 2 20
5 13 74.76 6 15.31 466 43 2.58 / 159.38 2 19
6 8 0.28 165 15.26 357 899 3.48 / 160.28 2 6
7 14 0.28 30 15.24 357 163 3.64 / 160.45 2 9
Average= 3.41
(KJ/cycle)

Cycle 45 GMT 3/ 3/2024 20:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 22 15.18 533 178 0.18 / 153.17 2 18
2 7 2005.84 38 14.90 2870 1625 1.80 / 154.79 2 13
3 13 1302.72 18 15.01 2046 553 2.36 / 155.34 2 18
4 13 717.04 18 15.12 1316 358 2.71 / 155.70 2 20
5 13 264.36 18 15.22 733 201 2.91 / 155.90 2 21
6 8 0.36 165 15.24 360 905 3.82 / 156.81 2 8
Average= 3.41
(KJ/cycle)

Cycle 44 GMT 22/ 2/2024 22:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 22 15.17 528 176 0.18 / 149.40 2 20
2 7 2005.00 38 14.89 2881 1630 1.81 / 151.03 2 15
3 13 1280.28 18 15.02 2030 549 2.36 / 151.58 2 17
4 13 660.60 18 15.13 1242 338 2.69 / 151.91 2 20
5 13 180.36 18 15.24 623 171 2.86 / 152.08 2 23
6 8 -0.12 165 15.24 359 903 3.77 / 152.99 2 9
Average= 3.40
(KJ/cycle)

Cycle 43 GMT 13/ 2/2024 2:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 22 15.17 539 180 0.18 / 145.62 2 18
2 7 2005.96 38 14.89 2877 1628 1.81 / 147.25 2 15
3 13 1258.36 18 15.02 1996 540 2.35 / 147.79 2 18
4 13 718.40 18 15.11 1317 358 2.71 / 148.14 2 21
5 13 183.36 18 15.25 627 172 2.88 / 148.32 2 22
6 8 0.00 165 15.25 359 903 3.78 / 149.22 2 7
Average= 3.39
(KJ/cycle)

Cycle 42 GMT 3/ 2/2024 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 22 15.17 518 173 0.17 / 141.84 2 20
2 7 2003.68 38 14.90 2891 1637 1.81 / 143.48 2 14
3 13 1302.44 18 15.02 2054 555 2.37 / 144.03 2 17
4 13 731.96 18 15.12 1339 364 2.73 / 144.40 2 19
5 13 203.68 9 15.24 661 91 2.82 / 144.49 2 23
6 13 19.80 9 15.30 381 52 2.87 / 144.54 2 3
7 8 0.12 165 15.25 357 898 3.77 / 145.44 2 10
Average= 3.38
(KJ/cycle)

Cycle 41 GMT 24/ 1/2024 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 22 15.18 554 185 0.19 / 137.94 2 21
2 7 2003.48 38 14.90 2871 1626 1.81 / 139.57 2 12
3 13 1282.76 18 15.04 2023 548 2.36 / 140.11 2 16
4 13 785.40 18 15.11 1401 381 2.74 / 140.49 2 19
5 13 232.28 10 15.25 696 106 2.85 / 140.60 2 22
6 8 0.08 165 15.26 359 904 3.75 / 141.50 2 7
7 14 0.08 30 15.23 358 164 3.91 / 141.67 2 7
Average= 3.37
(KJ/cycle)

Cycle 40 GMT 14/ 1/2024 13:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 22 15.19 543 181 0.18 / 134.06 2 20
2 7 2004.24 38 14.91 2879 1631 1.81 / 135.69 2 12
3 13 1250.80 18 15.04 1985 537 2.35 / 136.22 2 17
4 13 749.84 18 15.13 1361 371 2.72 / 136.60 2 19
5 13 197.48 9 15.26 647 89 2.81 / 136.68 2 22
6 8 0.64 165 15.26 360 906 3.72 / 137.59 2 7
7 14 0.64 30 15.23 360 164 3.88 / 137.76 2 10
Average= 3.36
(KJ/cycle)

Cycle 39 GMT 4/ 1/2024 16:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 22 15.19 541 181 0.18 / 130.35 2 20
2 7 2005.84 38 14.89 2878 1628 1.81 / 131.98 2 13
3 13 1295.08 18 15.01 2043 552 2.36 / 132.53 2 17
4 13 715.64 18 15.12 1310 357 2.72 / 132.89 2 19
5 13 176.48 9 15.26 619 85 2.80 / 132.97 2 22
6 8 0.16 165 15.25 358 901 3.70 / 133.87 2 11
Average= 3.35
(KJ/cycle)

Cycle 38 GMT 25/12/2023 19: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 23 15.20 546 191 0.19 / 126.76 2 19
2 7 1951.04 38 14.93 2804 1591 1.78 / 128.35 2 13
3 13 1197.24 18 15.06 1921 521 2.30 / 128.87 2 18
4 13 650.68 18 15.17 1232 336 2.64 / 129.21 2 20
5 13 148.56 8 15.28 579 71 2.71 / 129.28 2 23
6 8 0.16 165 15.27 355 894 3.60 / 130.17 2 6
Average= 3.34
(KJ/cycle)

Cycle 37 GMT 15/12/2023 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 23 15.21 546 191 0.19 / 123.03 2 20
2 3 1189.72 -1 15.53 0 0 0.00 / 123.03 2 20
3 3 1218.84 1 15.19 2007 30 0.22 / 123.07 2 13
4 7 2003.04 38 14.90 2868 1624 1.85 / 124.69 2 13
5 13 1283.60 18 15.04 2023 548 2.39 / 125.24 2 16
6 13 692.52 18 15.15 1288 351 2.74 / 125.59 2 20
7 13 157.60 8 15.28 591 72 2.82 / 125.66 2 23
8 8 0.00 165 15.27 360 907 3.72 / 126.57 2 8
Average= 3.33
(KJ/cycle)

Cycle 36 GMT 5/12/2023 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 23 15.19 528 184 0.18 / 119.31 2 20
2 7 2003.68 38 14.92 2872 1628 1.81 / 120.94 2 13
3 13 1256.48 18 15.05 1987 538 2.35 / 121.48 2 16
4 13 764.64 18 15.13 1377 375 2.73 / 121.85 2 19
5 13 176.84 9 15.29 623 86 2.81 / 121.94 2 21
6 8 0.24 165 15.27 360 907 3.72 / 122.84 2 6
Average= 3.32
(KJ/cycle)

Cycle 35 GMT 25/11/2023 23:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 23 15.21 548 192 0.19 / 115.37 2 19
2 7 2004.76 38 14.93 2875 1631 1.82 / 117.00 2 13
3 13 1296.44 18 15.04 2036 551 2.37 / 117.55 2 16
4 13 756.80 18 15.14 1367 373 2.75 / 117.93 2 19
5 13 253.64 11 15.27 721 121 2.87 / 118.05 2 22
6 8 0.24 165 15.27 362 912 3.78 / 118.96 2 6
7 14 0.24 30 15.25 360 165 3.94 / 119.12 2 10
Average= 3.31
(KJ/cycle)

Cycle 34 GMT 16/11/2023 3:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 22 15.21 529 177 0.18 / 111.60 2 19
2 7 2009.12 39 14.93 2873 1673 1.85 / 113.27 2 13
3 13 1257.88 18 15.06 1991 540 2.39 / 113.81 2 16
4 13 722.08 18 15.15 1325 361 2.75 / 114.17 2 20
5 13 223.52 10 15.27 680 104 2.85 / 114.27 2 22
6 8 -0.12 165 15.28 360 908 3.76 / 115.18 2 5
Average= 3.29
(KJ/cycle)

Cycle 33 GMT 6/11/2023 6:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 22 15.23 545 183 0.18 / 107.85 2 20
2 7 2006.68 38 14.93 2857 1621 1.80 / 109.47 2 12
3 13 1278.80 18 15.06 1997 541 2.34 / 110.02 2 17
4 13 699.84 18 15.15 1293 353 2.70 / 110.37 2 20
5 13 204.64 10 15.27 658 100 2.80 / 110.47 2 21
6 13 54.36 5 15.32 428 33 2.83 / 110.50 2 12
7 8 0.52 165 15.27 364 917 3.75 / 111.42 2 9
Average= 3.28
(KJ/cycle)

Cycle 32 GMT 27/10/2023 10:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 22 15.22 548 183 0.18 / 103.88 2 18
2 7 2003.76 38 14.94 2884 1637 1.82 / 105.52 2 12
3 13 1344.00 18 15.06 2095 568 2.39 / 106.08 2 17
4 13 755.12 18 15.16 1369 374 2.76 / 106.46 2 19
5 13 289.72 12 15.26 766 140 2.90 / 106.60 2 22
6 8 0.24 165 15.29 360 908 3.81 / 107.51 2 11
7 14 0.24 30 15.27 360 165 3.98 / 107.67 2 5
Average= 3.26
(KJ/cycle)

Cycle 31 GMT 17/10/2023 14:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 22 15.21 541 181 0.18 / 100.10 2 18
2 7 2002.96 39 14.93 2859 1665 1.85 / 101.76 2 12
3 13 1267.76 18 15.07 2007 544 2.39 / 102.31 2 17
4 13 729.32 18 15.17 1332 364 2.75 / 102.67 2 19
5 13 236.52 10 15.29 695 106 2.86 / 102.78 2 22
6 8 0.24 165 15.28 364 918 3.78 / 103.69 2 12
Average= 3.24
(KJ/cycle)

Cycle 30 GMT 7/10/2023 18:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 22 15.22 540 181 0.18 / 96.39 2 19
2 7 2010.04 38 14.95 2861 1625 1.81 / 98.02 2 13
3 13 1294.72 18 15.07 2041 554 2.36 / 98.57 2 16
4 13 708.64 18 15.17 1303 356 2.72 / 98.93 2 19
5 13 178.88 9 15.30 616 85 2.80 / 99.01 2 22
6 8 0.00 165 15.29 358 903 3.70 / 99.92 2 10
Average= 3.22
(KJ/cycle)

Cycle 29 GMT 27/ 9/2023 19:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 22 15.22 544 182 0.18 / 92.61 2 20
2 7 2007.88 38 14.94 2879 1634 1.82 / 94.24 2 13
3 13 1223.08 18 15.09 1955 531 2.35 / 94.77 2 16
4 13 667.80 18 15.18 1254 343 2.69 / 95.12 2 20
5 13 231.80 10 15.29 687 105 2.80 / 95.22 2 22
6 13 63.56 6 15.33 444 41 2.84 / 95.26 2 16
7 13 46.56 5 15.34 411 32 2.87 / 95.29 2 5
8 8 0.36 165 15.29 364 918 3.79 / 96.21 2 8
Average= 3.21
(KJ/cycle)

Cycle 28 GMT 17/ 9/2023 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 22 15.22 554 186 0.19 / 88.87 2 19
2 7 2006.88 38 14.95 2860 1625 1.81 / 90.49 2 13
3 13 1292.20 18 15.07 2029 550 2.36 / 91.04 2 16
4 13 678.68 18 15.18 1267 346 2.71 / 91.39 2 20
5 13 244.76 11 15.28 708 119 2.83 / 91.51 2 22
6 8 -0.24 165 15.28 365 920 3.75 / 92.43 2 10
Average= 3.19
(KJ/cycle)

Cycle 27 GMT 7/ 9/2023 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 22 15.22 549 184 0.18 / 84.92 2 19
2 7 2004.64 38 14.95 2875 1633 1.82 / 86.55 2 12
3 13 1227.24 18 15.08 1962 533 2.35 / 87.09 2 16
4 13 704.84 18 15.17 1302 356 2.71 / 87.44 2 19
5 13 261.68 11 15.27 731 123 2.83 / 87.56 2 22
6 13 45.68 5 15.34 396 30 2.86 / 87.59 2 6
7 8 0.04 165 15.28 365 920 3.78 / 88.51 2 7
8 14 0.04 30 15.26 363 166 3.94 / 88.68 2 7
Average= 3.17
(KJ/cycle)

Cycle 26 GMT 29/ 8/2023 2:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 22 15.26 550 185 0.18 / 81.20 2 20
2 7 2008.68 38 14.95 2883 1638 1.82 / 82.83 2 13
3 13 1260.60 18 15.08 1994 541 2.36 / 83.38 2 17
4 13 692.52 18 15.18 1287 352 2.72 / 83.73 2 19
5 13 201.60 9 15.30 655 90 2.81 / 83.82 2 22
6 8 0.04 165 15.30 364 919 3.72 / 84.74 2 6
Average= 3.14
(KJ/cycle)

Cycle 25 GMT 19/ 8/2023 4:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 23 15.22 549 192 0.19 / 78.20 2 19
2 3 1178.80 -1 15.54 0 0 0.00 / 78.20 2 19
3 7 1612.40 38 15.09 2377 1363 1.56 / 79.57 2 15
4 13 774.80 18 15.23 1391 381 1.94 / 79.95 2 20
5 13 267.12 11 15.34 747 126 2.06 / 80.07 2 22
6 8 -0.04 165 15.35 370 937 3.00 / 81.01 2 6
Average= 3.12
(KJ/cycle)

Cycle 24 GMT 9/ 8/2023 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 24 15.22 544 199 0.20 / 74.39 2 20
2 3 1143.16 -3 15.55 0 0 0.00 / 74.39 2 20
3 7 2003.60 38 14.96 2860 1626 1.82 / 76.02 2 13
4 13 1310.20 18 15.07 2064 560 2.38 / 76.58 2 16
5 13 768.04 18 15.16 1385 378 2.76 / 76.96 2 19
6 13 253.96 11 15.29 722 121 2.88 / 77.08 2 22
7 8 0.32 165 15.30 370 934 3.82 / 78.01 2 9
Average= 3.12
(KJ/cycle)

Cycle 23 GMT 30/ 7/2023 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 27 15.21 556 228 0.23 / 70.40 2 21
2 3 1022.64 -9 15.54 0 0 0.00 / 70.40 2 21
3 3 1249.56 1 15.19 2033 31 0.26 / 70.43 2 14
4 7 2003.28 38 14.95 2870 1630 1.89 / 72.06 2 12
5 13 1318.56 18 15.06 2073 562 2.45 / 72.62 2 16
6 13 720.84 18 15.16 1324 361 2.81 / 72.99 2 20
7 13 227.72 10 15.28 692 106 2.92 / 73.09 2 22
8 8 0.84 165 15.30 370 934 3.85 / 74.03 2 5
9 14 0.84 30 15.27 369 169 4.02 / 74.19 2 8
Average= 3.09
(KJ/cycle)

Cycle 22 GMT 20/ 7/2023 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 33 15.35 538 273 0.27 / 66.26 2 18
2 3 781.20 -21 15.59 0 0 0.00 / 66.26 2 18
3 3 1284.60 2 15.20 2078 63 0.34 / 66.32 2 12
4 7 2002.16 38 14.96 2885 1640 1.98 / 67.96 2 13
5 13 1329.20 18 15.07 2073 562 2.54 / 68.52 2 16
6 13 731.24 18 15.17 1339 366 2.90 / 68.89 2 19
7 13 183.00 9 15.31 630 87 2.99 / 68.98 2 22
8 13 16.64 18 15.35 383 106 3.10 / 69.08 2 3
9 8 0.28 165 15.30 366 924 4.02 / 70.01 2 6
10 14 0.28 30 15.27 363 166 4.19 / 70.17 2 7
Average= 3.05
(KJ/cycle)

Cycle 21 GMT 10/ 7/2023 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 27 15.28 540 223 0.22 / 63.92 2 18
2 10 751.84 4 15.22 1419 86 0.31 / 64.01 2 15
3 10 786.96 2 15.22 1455 44 0.35 / 64.05 2 15
4 3 790.08 1 15.28 1439 22 0.38 / 64.08 2 16
5 7 948.20 38 15.34 1572 916 1.29 / 64.99 2 17
6 13 129.76 7 15.49 554 60 1.35 / 65.05 2 20
7 8 0.76 165 15.45 366 933 2.28 / 65.99 2 4
Average= 3.00
(KJ/cycle)

Cycle 20 GMT 30/ 6/2023 22:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 27 15.30 549 227 0.23 / 61.24 2 18
2 7 1378.28 38 15.17 2102 1212 1.44 / 62.45 2 14
3 13 573.08 18 15.30 1110 306 1.74 / 62.75 2 19
4 13 53.96 5 15.43 412 32 1.78 / 62.78 2 13
5 8 -0.52 165 15.38 361 916 2.69 / 63.70 2 5
Average= 3.03
(KJ/cycle)

Cycle 19 GMT 21/ 6/2023 1:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 28 15.23 550 235 0.23 / 58.78 2 18
2 7 1223.72 38 15.23 1925 1114 1.35 / 59.89 2 15
3 13 313.64 13 15.41 802 161 1.51 / 60.05 2 20
4 13 49.48 5 15.46 404 31 1.54 / 60.08 2 5
5 8 0.24 165 15.39 364 924 2.46 / 61.01 2 6
Average= 3.05
(KJ/cycle)

Cycle 18 GMT 11/ 6/2023 5:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 15.28 544 233 0.23 / 55.00 2 17
2 7 2003.76 38 14.97 2888 1643 1.88 / 56.64 2 11
3 13 1281.48 18 15.10 2022 550 2.43 / 57.19 2 15
4 13 649.04 18 15.20 1230 337 2.76 / 57.52 2 18
5 13 209.56 10 15.31 669 102 2.86 / 57.63 2 21
6 8 0.44 165 15.31 363 917 3.78 / 58.54 2 9
Average= 3.08
(KJ/cycle)

Cycle 17 GMT 1/ 6/2023 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 28 15.26 547 234 0.23 / 52.17 2 17
2 7 1457.32 38 15.16 2193 1263 1.50 / 53.43 2 14
3 13 626.96 18 15.30 1180 325 1.82 / 53.76 2 18
4 13 178.64 9 15.39 614 85 1.91 / 53.84 2 21
5 8 0.12 165 15.36 364 923 2.83 / 54.76 2 5
Average= 3.04
(KJ/cycle)

Cycle 16 GMT 22/ 5/2023 10:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 27 15.29 545 225 0.22 / 48.80 2 17
2 7 1695.08 38 15.08 2501 1433 1.66 / 50.23 2 12
3 13 862.20 18 15.23 1503 412 2.07 / 50.64 2 17
4 13 333.00 13 15.32 830 165 2.24 / 50.81 2 20
5 13 48.84 5 15.40 417 32 2.27 / 50.84 2 5
6 8 -0.24 165 15.35 365 924 3.19 / 51.77 2 6
7 14 -0.24 30 15.32 364 167 3.36 / 51.93 2 7
Average= 3.05
(KJ/cycle)

Cycle 15 GMT 12/ 5/2023 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 27 15.32 557 230 0.23 / 45.91 2 17
2 7 1401.64 38 15.19 2125 1227 1.46 / 47.13 2 14
3 13 545.00 18 15.34 1090 301 1.76 / 47.43 2 18
4 13 94.72 6 15.43 503 47 1.80 / 47.48 2 20
5 8 -0.24 165 15.39 364 924 2.73 / 48.41 2 10
6 14 -0.24 30 15.36 365 168 2.90 / 48.57 2 6
Average= 3.04
(KJ/cycle)

Cycle 14 GMT 2/ 5/2023 16: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 27 15.26 545 225 0.22 / 43.40 2 16
2 7 1220.16 38 15.25 1905 1104 1.33 / 44.50 2 15
3 13 421.16 18 15.39 909 252 1.58 / 44.76 2 19
4 8 0.48 165 15.41 362 920 2.50 / 45.68 2 4
Average= 3.05
(KJ/cycle)

Cycle 13 GMT 22/ 4/2023 19:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 26 15.23 538 213 0.21 / 39.49 2 15
2 3 1049.88 1 15.20 1803 27 0.24 / 39.52 2 12
3 7 1991.44 38 14.99 2847 1622 1.86 / 41.14 2 10
4 13 1210.52 18 15.11 1934 526 2.39 / 41.67 2 15
5 13 699.64 18 15.20 1296 355 2.74 / 42.02 2 17
6 13 147.56 8 15.33 578 71 2.81 / 42.09 2 20
7 8 -0.24 165 15.32 363 918 3.73 / 43.01 2 6
8 14 -0.24 30 15.29 362 166 3.90 / 43.18 2 5
Average= 3.08
(KJ/cycle)

Cycle 12 GMT 12/ 4/2023 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 26 15.26 539 214 0.21 / 35.69 2 17
2 7 2003.04 38 14.99 2866 1633 1.85 / 37.33 2 9
3 13 1284.24 18 15.09 2026 550 2.40 / 37.88 2 13
4 13 750.80 18 15.18 1362 372 2.77 / 38.25 2 16
5 13 212.24 10 15.30 667 102 2.87 / 38.35 2 18
6 8 0.12 165 15.31 367 927 3.80 / 39.28 2 8
Average= 3.02
(KJ/cycle)

Cycle 11 GMT 3/ 4/2023 1:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 26 15.31 545 217 0.22 / 32.72 2 16
2 7 1576.80 38 15.12 2339 1344 1.56 / 34.06 2 13
3 13 775.52 18 15.24 1371 376 1.94 / 34.44 2 17
4 13 262.12 11 15.35 731 123 2.06 / 34.56 2 20
5 8 0.32 165 15.35 364 922 2.98 / 35.48 2 4
Average= 2.96
(KJ/cycle)

Cycle 10 GMT 24/ 3/2023 4: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 26 15.29 540 215 0.21 / 30.18 2 16
2 7 1242.48 39 15.23 1929 1146 1.36 / 31.33 2 13
3 13 409.40 18 15.38 898 249 1.61 / 31.57 2 18
4 8 0.08 165 15.40 364 925 2.53 / 32.50 2 10
Average= 2.95
(KJ/cycle)

Cycle 9 GMT 14/ 3/2023 7:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 24 15.34 534 197 0.20 / 27.28 2 16
2 10 1026.12 2 15.23 1756 53 0.25 / 27.34 2 13
3 3 988.60 -1 15.58 0 0 0.05 / 27.34 2 13
4 7 1461.60 38 15.17 2199 1268 1.52 / 28.61 2 13
5 13 702.68 18 15.30 1272 350 1.87 / 28.96 2 17
6 13 203.52 9 15.39 632 88 1.96 / 29.04 2 20
7 8 -0.12 165 15.38 363 921 2.88 / 29.96 2 5
Average= 3.00
(KJ/cycle)

Cycle 8 GMT 4/ 3/2023 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 28 15.28 543 232 0.23 / 24.10 2 14
2 3 909.48 -2 15.59 0 0 0.00 / 24.10 2 14
3 3 959.64 -1 15.62 0 0 0.00 / 24.10 2 14
4 7 1207.12 74 15.17 1865 2094 2.33 / 26.20 2 16
5 8 -0.12 165 15.41 350 890 3.22 / 27.09 2 4
Average= 3.01
(KJ/cycle)

Cycle 7 GMT 22/ 2/2023 14:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 26 15.29 520 207 0.21 / 20.56 2 14
2 7 1114.92 74 15.17 1780 1998 2.20 / 22.55 2 15
3 8 0.32 165 15.40 358 910 3.11 / 23.46 2 6
4 14 0.32 75 15.35 355 409 3.52 / 23.87 2 4
Average= 2.98
(KJ/cycle)

Cycle 6 GMT 21/ 2/2023 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 25 15.29 528 202 0.20 / 17.10 2 14
2 7 1082.80 74 15.17 1744 1958 2.16 / 19.05 2 15
3 8 0.16 165 15.39 352 894 3.05 / 19.95 2 9
4 14 0.16 75 15.35 349 402 3.46 / 20.35 2 5
Average= 2.91
(KJ/cycle)

Cycle 5 GMT 20/ 2/2023 16:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 25 15.31 531 203 0.20 / 13.61 2 14
2 7 1073.24 75 15.18 1728 1967 2.17 / 15.58 2 15
3 8 -0.32 165 15.39 356 904 3.07 / 16.49 2 7
4 14 -0.32 75 15.34 354 407 3.48 / 16.89 2 7
Average= 2.82
(KJ/cycle)

Cycle 4 GMT 19/ 2/2023 17: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 25 15.31 498 191 0.19 / 10.46 2 14
2 3 1024.04 1 15.32 1741 27 0.22 / 10.48 2 11
3 7 1154.96 74 15.15 1805 2024 2.24 / 12.51 2 14
4 8 0.04 165 15.38 357 906 3.15 / 13.41 2 4
Average= 2.68
(KJ/cycle)

Cycle 3 GMT 18/ 2/2023 17:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 20 15.35 497 153 0.15 / 7.36 2 14
2 10 1022.28 4 15.23 1739 106 0.26 / 7.46 2 11
3 3 1067.28 2 15.28 1793 55 0.31 / 7.52 2 12
4 7 1085.60 74 15.18 1713 1924 2.24 / 9.44 2 15
5 8 0.00 165 15.40 323 821 3.06 / 10.26 2 4
Average= 2.57
(KJ/cycle)

Cycle 2 GMT 17/ 2/2023 18:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 31 15.31 495 235 0.23 / 4.59 2 14
2 3 802.36 -4 15.64 0 0 0.00 / 4.59 2 14
3 3 830.16 -3 15.65 0 0 0.00 / 4.59 2 14
4 7 971.04 75 15.23 1572 1796 2.03 / 6.39 2 15
5 8 -0.12 165 15.41 321 816 2.85 / 7.21 2 8
Average= 2.40
(KJ/cycle)

Cycle 1 GMT 16/ 2/2023 19:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 26 15.50 431 174 0.17 / 1.77 2 6
2 7 982.08 74 15.19 1585 1782 1.96 / 3.55 2 15
3 8 -0.04 165 15.39 320 813 2.77 / 4.36 2 9
Average= 2.18
(KJ/cycle)

Cycle 0 GMT 16/ 2/2023 8:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 84.00 25 15.64 381 149 0.15 / 0.15 2 3
2 7 99.84 75 15.61 402 471 0.62 / 0.62 2 4
3 8 0.16 240 15.58 260 972 1.59 / 1.59 2 15
Average= 1.59
(KJ/cycle)