SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 40 | 13.81 | 591 | 326 | 0.33 / 543.91 | 2 | 3 |
2 | 12 | 1130.68 | 8 | 11.98 | 2067 | 198 | 0.52 / 544.11 | 2 | 2 |
3 | 7 | 2001.12 | 51 | 10.84 | 3325 | 1838 | 2.36 / 545.94 | 2 | 2 |
4 | 13 | 1851.80 | 37 | 12.20 | 3105 | 1402 | 3.76 / 547.35 | 2 | 2 |
5 | 13 | 930.08 | 37 | 13.14 | 1714 | 833 | 4.60 / 548.18 | 2 | 3 |
6 | 13 | 65.40 | 6 | 14.05 | 500 | 42 | 4.64 / 548.22 | 2 | 3 |
7 | 13 | 55.88 | 6 | 14.02 | 501 | 42 | 4.68 / 548.26 | 2 | 4 |
8 | 13 | 52.80 | 6 | 13.98 | 503 | 42 | 4.72 / 548.31 | 2 | 4 |
9 | 13 | 48.40 | 6 | 13.98 | 496 | 42 | 4.77 / 548.35 | 2 | 4 |
10 | 8 | 0.40 | 190 | 13.78 | 416 | 1089 | 5.85 / 549.44 | 2 | 21 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 40 | 13.82 | 575 | 318 | 0.32 / 538.17 | 2 | 3 |
2 | 12 | 1123.96 | 8 | 11.91 | 2047 | 195 | 0.51 / 538.36 | 2 | 2 |
3 | 7 | 2014.24 | 50 | 10.85 | 3342 | 1813 | 2.33 / 540.17 | 2 | 2 |
4 | 13 | 1876.80 | 37 | 12.16 | 3145 | 1415 | 3.74 / 541.59 | 2 | 2 |
5 | 13 | 943.60 | 37 | 13.12 | 1741 | 845 | 4.59 / 542.44 | 2 | 4 |
6 | 13 | 95.28 | 6 | 14.01 | 554 | 47 | 4.63 / 542.48 | 2 | 4 |
7 | 8 | 0.04 | 190 | 13.78 | 420 | 1100 | 5.73 / 543.58 | 2 | 17 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 40 | 13.84 | 559 | 309 | 0.31 / 532.20 | 2 | 3 |
2 | 12 | 1124.32 | 8 | 11.92 | 2027 | 193 | 0.50 / 532.39 | 2 | 2 |
3 | 7 | 2002.60 | 50 | 10.88 | 3324 | 1808 | 2.31 / 534.20 | 2 | 2 |
4 | 13 | 1854.24 | 37 | 12.17 | 3103 | 1397 | 3.71 / 535.60 | 2 | 2 |
5 | 13 | 1078.16 | 37 | 13.02 | 1934 | 932 | 4.64 / 536.53 | 2 | 4 |
6 | 13 | 76.60 | 6 | 14.05 | 511 | 43 | 4.68 / 536.57 | 2 | 3 |
7 | 13 | 6.36 | 37 | 14.05 | 420 | 218 | 4.90 / 536.79 | 2 | 5 |
8 | 8 | 0.28 | 190 | 13.69 | 407 | 1059 | 5.96 / 537.85 | 2 | 27 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 40 | 13.85 | 580 | 321 | 0.32 / 526.59 | 2 | 3 |
2 | 3 | 1021.88 | 1 | 11.30 | 1913 | 22 | 0.34 / 526.61 | 2 | 2 |
3 | 12 | 1146.88 | 8 | 11.91 | 2070 | 197 | 0.54 / 526.81 | 2 | 2 |
4 | 7 | 2002.24 | 50 | 10.94 | 3325 | 1819 | 2.36 / 528.63 | 2 | 2 |
5 | 13 | 1857.84 | 37 | 12.18 | 3114 | 1403 | 3.76 / 530.03 | 2 | 2 |
6 | 13 | 755.52 | 37 | 13.31 | 1456 | 717 | 4.48 / 530.75 | 2 | 4 |
7 | 13 | 102.08 | 6 | 14.04 | 558 | 47 | 4.53 / 530.80 | 2 | 4 |
8 | 8 | 0.12 | 190 | 13.79 | 417 | 1093 | 5.62 / 531.89 | 2 | 20 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 41 | 13.86 | 558 | 317 | 0.32 / 520.51 | 2 | 3 |
2 | 3 | 972.68 | -1 | 13.86 | 558 | 0 | 0.00 / 520.51 | 2 | 3 |
3 | 12 | 1143.44 | 8 | 11.94 | 2084 | 199 | 0.52 / 520.71 | 2 | 2 |
4 | 7 | 2002.44 | 50 | 10.95 | 3319 | 1817 | 2.33 / 522.53 | 2 | 2 |
5 | 13 | 1854.80 | 37 | 12.20 | 3091 | 1395 | 3.73 / 523.92 | 2 | 2 |
6 | 13 | 914.04 | 37 | 13.18 | 1679 | 819 | 4.55 / 524.74 | 2 | 4 |
7 | 13 | 41.36 | 6 | 14.06 | 472 | 40 | 4.59 / 524.78 | 2 | 3 |
8 | 13 | 17.84 | 37 | 14.02 | 435 | 226 | 4.81 / 525.01 | 2 | 4 |
9 | 13 | 6.04 | 37 | 13.91 | 419 | 216 | 5.03 / 525.22 | 2 | 11 |
10 | 8 | -0.04 | 190 | 13.62 | 405 | 1048 | 6.08 / 526.27 | 2 | 28 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 40 | 13.86 | 563 | 312 | 0.31 / 514.73 | 2 | 3 |
2 | 12 | 1139.56 | 8 | 11.97 | 2054 | 197 | 0.51 / 514.92 | 2 | 2 |
3 | 7 | 2002.80 | 50 | 11.00 | 3315 | 1823 | 2.33 / 516.75 | 2 | 2 |
4 | 13 | 1859.32 | 37 | 12.19 | 3106 | 1401 | 3.73 / 518.15 | 2 | 2 |
5 | 13 | 761.56 | 37 | 13.31 | 1451 | 715 | 4.45 / 518.86 | 2 | 4 |
6 | 13 | 64.72 | 37 | 14.00 | 489 | 253 | 4.70 / 519.12 | 2 | 4 |
7 | 8 | 0.40 | 190 | 13.77 | 412 | 1078 | 5.78 / 520.19 | 2 | 23 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 40 | 13.89 | 559 | 311 | 0.31 / 508.80 | 2 | 3 |
2 | 12 | 1143.28 | 8 | 11.98 | 2079 | 199 | 0.51 / 509.00 | 2 | 2 |
3 | 7 | 2002.64 | 51 | 10.99 | 3315 | 1858 | 2.37 / 510.86 | 2 | 2 |
4 | 13 | 1853.76 | 37 | 12.21 | 3095 | 1398 | 3.77 / 512.26 | 2 | 2 |
5 | 13 | 906.16 | 37 | 13.20 | 1669 | 815 | 4.58 / 513.07 | 2 | 4 |
6 | 13 | 59.12 | 37 | 14.01 | 485 | 251 | 4.83 / 513.32 | 2 | 4 |
7 | 8 | -0.16 | 190 | 13.79 | 417 | 1093 | 5.93 / 514.41 | 2 | 22 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 40 | 13.88 | 544 | 302 | 0.30 / 502.94 | 2 | 3 |
2 | 12 | 1148.36 | 8 | 12.08 | 2037 | 197 | 0.50 / 503.13 | 2 | 2 |
3 | 7 | 2002.44 | 50 | 11.03 | 3302 | 1821 | 2.32 / 504.96 | 2 | 2 |
4 | 13 | 1856.04 | 37 | 12.21 | 3095 | 1398 | 3.72 / 506.35 | 2 | 2 |
5 | 13 | 909.32 | 37 | 13.18 | 1691 | 825 | 4.54 / 507.18 | 2 | 4 |
6 | 13 | 48.48 | 37 | 14.02 | 471 | 244 | 4.79 / 507.42 | 2 | 5 |
7 | 8 | 1.08 | 190 | 13.76 | 408 | 1067 | 5.85 / 508.49 | 2 | 24 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 40 | 13.88 | 556 | 309 | 0.31 / 497.19 | 2 | 3 |
2 | 12 | 1125.96 | 8 | 12.03 | 2041 | 196 | 0.51 / 497.38 | 2 | 2 |
3 | 7 | 2001.72 | 51 | 11.05 | 3302 | 1861 | 2.37 / 499.24 | 2 | 2 |
4 | 13 | 1852.80 | 37 | 12.21 | 3084 | 1393 | 3.76 / 500.64 | 2 | 2 |
5 | 13 | 918.76 | 37 | 13.18 | 1690 | 824 | 4.58 / 501.46 | 2 | 4 |
6 | 13 | 65.44 | 6 | 14.07 | 493 | 42 | 4.62 / 501.50 | 2 | 4 |
7 | 13 | 56.60 | 6 | 14.05 | 485 | 41 | 4.67 / 501.54 | 2 | 4 |
8 | 13 | 48.88 | 6 | 14.01 | 476 | 40 | 4.71 / 501.58 | 2 | 4 |
9 | 8 | 0.32 | 190 | 13.80 | 401 | 1051 | 5.76 / 502.64 | 2 | 24 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 40 | 13.86 | 571 | 317 | 0.32 / 491.61 | 2 | 3 |
2 | 12 | 1143.16 | 8 | 12.05 | 2046 | 197 | 0.51 / 491.81 | 2 | 2 |
3 | 7 | 2000.96 | 50 | 11.07 | 3311 | 1833 | 2.35 / 493.64 | 2 | 2 |
4 | 13 | 1849.80 | 37 | 12.23 | 3087 | 1397 | 3.74 / 495.04 | 2 | 2 |
5 | 13 | 756.84 | 37 | 13.33 | 1444 | 712 | 4.46 / 495.75 | 2 | 4 |
6 | 13 | 65.12 | 6 | 14.08 | 489 | 41 | 4.50 / 495.79 | 2 | 4 |
7 | 13 | 46.56 | 6 | 14.05 | 473 | 40 | 4.54 / 495.83 | 2 | 3 |
8 | 8 | 0.56 | 190 | 13.80 | 400 | 1049 | 5.59 / 496.88 | 2 | 20 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 40 | 13.86 | 568 | 315 | 0.31 / 485.84 | 2 | 3 |
2 | 12 | 1136.60 | 8 | 12.04 | 2051 | 198 | 0.51 / 486.04 | 2 | 2 |
3 | 7 | 2002.24 | 51 | 11.10 | 3308 | 1873 | 2.39 / 487.91 | 2 | 2 |
4 | 13 | 1857.48 | 37 | 12.22 | 3096 | 1400 | 3.78 / 489.31 | 2 | 2 |
5 | 13 | 911.44 | 37 | 13.20 | 1696 | 828 | 4.61 / 490.14 | 2 | 4 |
6 | 13 | 83.32 | 6 | 14.08 | 522 | 44 | 4.66 / 490.18 | 2 | 4 |
7 | 13 | 64.84 | 6 | 14.06 | 510 | 43 | 4.70 / 490.22 | 2 | 4 |
8 | 8 | 0.04 | 190 | 13.82 | 407 | 1069 | 5.77 / 491.29 | 2 | 19 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 39 | 13.86 | 581 | 314 | 0.31 / 479.92 | 2 | 3 |
2 | 3 | 1022.08 | 1 | 11.35 | 1889 | 21 | 0.34 / 479.94 | 2 | 2 |
3 | 12 | 1152.72 | 8 | 12.14 | 2050 | 199 | 0.53 / 480.14 | 2 | 2 |
4 | 7 | 2005.96 | 50 | 11.17 | 3293 | 1839 | 2.37 / 481.98 | 2 | 2 |
5 | 13 | 1859.72 | 37 | 12.24 | 3088 | 1398 | 3.77 / 483.38 | 2 | 2 |
6 | 13 | 911.04 | 37 | 13.20 | 1672 | 817 | 4.59 / 484.19 | 2 | 4 |
7 | 13 | 62.48 | 6 | 14.05 | 490 | 41 | 4.63 / 484.24 | 2 | 4 |
8 | 13 | 18.52 | 37 | 14.04 | 442 | 230 | 4.86 / 484.46 | 2 | 5 |
9 | 8 | 0.40 | 190 | 13.66 | 408 | 1059 | 5.92 / 485.52 | 2 | 24 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 31 | 13.93 | 563 | 243 | 0.24 / 474.01 | 2 | 3 |
2 | 10 | 1050.04 | 4 | 13.62 | 1916 | 104 | 0.35 / 474.12 | 2 | 3 |
3 | 3 | 1115.84 | 3 | 13.38 | 2059 | 83 | 0.43 / 474.20 | 2 | 3 |
4 | 3 | 1029.44 | 1 | 13.01 | 1934 | 25 | 0.46 / 474.23 | 2 | 2 |
5 | 12 | 1149.36 | 8 | 12.09 | 2056 | 199 | 0.65 / 474.42 | 2 | 2 |
6 | 7 | 2002.56 | 50 | 11.15 | 3299 | 1839 | 2.49 / 476.26 | 2 | 2 |
7 | 13 | 1852.44 | 37 | 12.24 | 3099 | 1403 | 3.90 / 477.67 | 2 | 2 |
8 | 13 | 911.88 | 37 | 13.21 | 1673 | 818 | 4.71 / 478.49 | 2 | 4 |
9 | 13 | 63.00 | 6 | 14.10 | 483 | 41 | 4.76 / 478.53 | 2 | 3 |
10 | 13 | 42.48 | 6 | 14.05 | 456 | 38 | 4.79 / 478.56 | 2 | 4 |
11 | 8 | -0.16 | 190 | 13.83 | 396 | 1041 | 5.83 / 479.61 | 2 | 20 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 30 | 13.95 | 572 | 239 | 0.24 / 468.22 | 2 | 3 |
2 | 3 | 1049.40 | 1 | 13.01 | 1983 | 26 | 0.27 / 468.25 | 2 | 2 |
3 | 3 | 1020.28 | 1 | 12.31 | 1916 | 24 | 0.29 / 468.27 | 2 | 2 |
4 | 12 | 1152.88 | 8 | 12.16 | 2101 | 204 | 0.49 / 468.47 | 2 | 2 |
5 | 7 | 2002.96 | 51 | 11.21 | 3306 | 1890 | 2.38 / 470.36 | 2 | 2 |
6 | 13 | 1860.92 | 37 | 12.23 | 3106 | 1405 | 3.79 / 471.77 | 2 | 2 |
7 | 13 | 755.12 | 37 | 13.33 | 1455 | 718 | 4.51 / 472.49 | 2 | 4 |
8 | 13 | 18.12 | 37 | 14.05 | 435 | 226 | 4.73 / 472.71 | 2 | 4 |
9 | 8 | 0.36 | 190 | 13.75 | 405 | 1058 | 5.79 / 473.77 | 2 | 22 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 31 | 13.92 | 560 | 242 | 0.24 / 463.74 | 2 | 3 |
2 | 3 | 971.92 | -1 | 13.92 | 560 | 0 | 0.00 / 463.74 | 2 | 3 |
3 | 12 | 1149.28 | 8 | 12.14 | 2087 | 203 | 0.44 / 463.94 | 2 | 2 |
4 | 7 | 2002.72 | 50 | 11.23 | 3306 | 1856 | 2.30 / 465.80 | 2 | 2 |
5 | 13 | 1849.64 | 37 | 12.24 | 3077 | 1394 | 3.69 / 467.19 | 2 | 2 |
6 | 13 | 742.88 | 37 | 13.35 | 1433 | 708 | 4.40 / 467.90 | 2 | 4 |
7 | 13 | 64.44 | 6 | 14.06 | 505 | 43 | 4.44 / 467.94 | 2 | 3 |
8 | 13 | 52.88 | 6 | 14.06 | 489 | 41 | 4.49 / 467.98 | 2 | 4 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 30 | 13.95 | 567 | 237 | 0.24 / 459.31 | 2 | 3 |
2 | 12 | 1140.76 | 8 | 12.19 | 2076 | 202 | 0.44 / 459.51 | 2 | 2 |
3 | 7 | 2002.20 | 50 | 11.22 | 3323 | 1864 | 2.30 / 461.38 | 2 | 2 |
4 | 13 | 1847.64 | 37 | 12.26 | 3088 | 1401 | 3.70 / 462.78 | 2 | 2 |
5 | 13 | 748.40 | 37 | 13.33 | 1451 | 716 | 4.42 / 463.49 | 2 | 4 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 30 | 13.94 | 567 | 237 | 0.24 / 454.83 | 2 | 3 |
2 | 12 | 1122.16 | 8 | 12.13 | 2037 | 198 | 0.43 / 455.03 | 2 | 2 |
3 | 7 | 2012.92 | 50 | 11.18 | 3345 | 1870 | 2.30 / 456.90 | 2 | 2 |
4 | 13 | 1864.08 | 37 | 12.23 | 3115 | 1410 | 3.71 / 458.31 | 2 | 2 |
5 | 13 | 765.72 | 37 | 13.33 | 1463 | 722 | 4.44 / 459.03 | 2 | 4 |
6 | 13 | 66.00 | 6 | 14.10 | 501 | 42 | 4.48 / 459.07 | 2 | 4 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 30 | 13.93 | 571 | 239 | 0.24 / 450.48 | 2 | 3 |
2 | 12 | 1124.00 | 8 | 12.28 | 2021 | 199 | 0.44 / 450.68 | 2 | 2 |
3 | 7 | 2010.24 | 50 | 11.22 | 3322 | 1864 | 2.30 / 452.54 | 2 | 2 |
4 | 13 | 1706.64 | 37 | 12.41 | 2887 | 1326 | 3.63 / 453.86 | 2 | 3 |
5 | 13 | 782.52 | 37 | 13.33 | 1482 | 731 | 4.36 / 454.60 | 2 | 4 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 29 | 13.93 | 562 | 227 | 0.23 / 445.92 | 2 | 3 |
2 | 3 | 1026.76 | 1 | 12.29 | 1942 | 24 | 0.25 / 445.95 | 2 | 2 |
3 | 12 | 1148.16 | 8 | 12.33 | 2062 | 203 | 0.45 / 446.15 | 2 | 2 |
4 | 7 | 2001.88 | 50 | 11.29 | 3325 | 1877 | 2.33 / 448.03 | 2 | 2 |
5 | 13 | 1846.12 | 37 | 12.24 | 3100 | 1404 | 3.74 / 449.43 | 2 | 2 |
6 | 13 | 879.56 | 37 | 13.22 | 1648 | 806 | 4.54 / 450.24 | 2 | 4 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 29 | 13.95 | 559 | 226 | 0.23 / 441.47 | 2 | 3 |
2 | 12 | 1144.68 | 8 | 12.22 | 2067 | 202 | 0.43 / 441.67 | 2 | 2 |
3 | 7 | 2001.32 | 50 | 11.30 | 3322 | 1877 | 2.31 / 443.55 | 2 | 2 |
4 | 13 | 1846.84 | 37 | 12.27 | 3095 | 1405 | 3.71 / 444.95 | 2 | 2 |
5 | 13 | 734.12 | 37 | 13.37 | 1422 | 703 | 4.41 / 445.66 | 2 | 4 |
6 | 13 | 45.72 | 6 | 14.10 | 469 | 40 | 4.45 / 445.70 | 2 | 3 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 30 | 13.94 | 559 | 234 | 0.23 / 437.04 | 2 | 3 |
2 | 3 | 961.12 | -1 | 13.94 | 559 | 0 | 0.00 / 437.04 | 2 | 3 |
3 | 12 | 1128.56 | 8 | 12.31 | 2035 | 200 | 0.43 / 437.24 | 2 | 2 |
4 | 7 | 2001.04 | 51 | 11.28 | 3317 | 1908 | 2.34 / 439.15 | 2 | 2 |
5 | 13 | 1852.20 | 37 | 12.26 | 3100 | 1406 | 3.75 / 440.56 | 2 | 2 |
6 | 13 | 724.48 | 37 | 13.38 | 1387 | 687 | 4.44 / 441.24 | 2 | 4 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 30 | 13.97 | 558 | 234 | 0.23 / 432.61 | 2 | 3 |
2 | 12 | 1140.04 | 8 | 12.25 | 2067 | 203 | 0.44 / 432.82 | 2 | 2 |
3 | 7 | 2011.60 | 50 | 11.33 | 3326 | 1884 | 2.32 / 434.70 | 2 | 2 |
4 | 13 | 1852.60 | 37 | 12.28 | 3079 | 1399 | 3.72 / 436.10 | 2 | 2 |
5 | 13 | 743.52 | 37 | 13.36 | 1436 | 710 | 4.43 / 436.81 | 2 | 4 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 30 | 13.98 | 534 | 224 | 0.22 / 428.00 | 2 | 3 |
2 | 12 | 1114.16 | 8 | 12.34 | 2000 | 197 | 0.42 / 428.20 | 2 | 2 |
3 | 7 | 2009.04 | 50 | 11.33 | 3320 | 1881 | 2.30 / 430.08 | 2 | 2 |
4 | 13 | 1856.76 | 37 | 12.26 | 3102 | 1407 | 3.71 / 431.49 | 2 | 2 |
5 | 13 | 906.60 | 37 | 13.21 | 1662 | 812 | 4.52 / 432.30 | 2 | 4 |
6 | 13 | 79.08 | 6 | 14.09 | 501 | 42 | 4.56 / 432.34 | 2 | 3 |
7 | 13 | 45.08 | 6 | 14.10 | 455 | 38 | 4.60 / 432.38 | 2 | 4 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 30 | 13.99 | 548 | 230 | 0.23 / 423.56 | 2 | 3 |
2 | 12 | 1133.28 | 8 | 12.29 | 2066 | 203 | 0.43 / 423.77 | 2 | 2 |
3 | 7 | 2012.60 | 50 | 11.34 | 3338 | 1893 | 2.33 / 425.66 | 2 | 2 |
4 | 13 | 1857.88 | 37 | 12.27 | 3106 | 1410 | 3.74 / 427.07 | 2 | 2 |
5 | 13 | 747.24 | 37 | 13.36 | 1428 | 706 | 4.44 / 427.78 | 2 | 4 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 31 | 13.92 | 563 | 243 | 0.24 / 418.95 | 2 | 3 |
2 | 3 | 954.64 | -1 | 13.92 | 563 | 0 | 0.00 / 418.95 | 2 | 3 |
3 | 12 | 1116.28 | 8 | 12.34 | 2033 | 201 | 0.44 / 419.15 | 2 | 2 |
4 | 7 | 2009.24 | 51 | 11.32 | 3334 | 1925 | 2.37 / 421.08 | 2 | 2 |
5 | 13 | 1855.64 | 37 | 12.27 | 3115 | 1414 | 3.78 / 422.49 | 2 | 2 |
6 | 13 | 877.60 | 37 | 13.23 | 1639 | 802 | 4.58 / 423.29 | 2 | 4 |
7 | 13 | 76.00 | 6 | 14.09 | 510 | 43 | 4.63 / 423.33 | 2 | 4 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 30 | 13.98 | 546 | 229 | 0.23 / 414.45 | 2 | 3 |
2 | 3 | 1035.76 | 1 | 13.00 | 1942 | 25 | 0.25 / 414.47 | 2 | 2 |
3 | 12 | 1133.48 | 8 | 12.21 | 2077 | 203 | 0.46 / 414.67 | 2 | 2 |
4 | 7 | 2001.80 | 50 | 11.34 | 3327 | 1886 | 2.34 / 416.56 | 2 | 2 |
5 | 13 | 1852.60 | 37 | 12.28 | 3094 | 1406 | 3.75 / 417.97 | 2 | 3 |
6 | 13 | 735.00 | 37 | 13.38 | 1412 | 699 | 4.45 / 418.67 | 2 | 4 |
7 | 13 | 51.16 | 6 | 14.11 | 483 | 41 | 4.49 / 418.71 | 2 | 3 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 30 | 13.98 | 563 | 236 | 0.24 / 409.92 | 2 | 3 |
2 | 12 | 1110.88 | 8 | 12.30 | 2039 | 201 | 0.44 / 410.12 | 2 | 2 |
3 | 7 | 2011.44 | 51 | 11.33 | 3322 | 1920 | 2.36 / 412.04 | 2 | 2 |
4 | 13 | 1704.64 | 37 | 12.46 | 2882 | 1329 | 3.68 / 413.37 | 2 | 3 |
5 | 13 | 779.72 | 37 | 13.34 | 1479 | 730 | 4.41 / 414.10 | 2 | 4 |
6 | 13 | 65.28 | 6 | 14.12 | 488 | 41 | 4.46 / 414.14 | 2 | 4 |
7 | 13 | 54.28 | 6 | 14.08 | 482 | 41 | 4.50 / 414.18 | 2 | 4 |
8 | 13 | 47.56 | 6 | 14.05 | 476 | 40 | 4.54 / 414.22 | 2 | 4 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 29 | 13.99 | 564 | 229 | 0.23 / 405.62 | 2 | 3 |
2 | 12 | 1144.80 | 8 | 12.37 | 2077 | 206 | 0.43 / 405.82 | 2 | 2 |
3 | 7 | 2001.20 | 51 | 11.44 | 3301 | 1926 | 2.36 / 407.75 | 2 | 2 |
4 | 13 | 1687.40 | 37 | 12.49 | 2841 | 1313 | 3.67 / 409.06 | 2 | 3 |
5 | 13 | 615.44 | 37 | 13.48 | 1237 | 617 | 4.29 / 409.68 | 2 | 4 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 29 | 13.97 | 571 | 231 | 0.23 / 401.08 | 2 | 3 |
2 | 12 | 1110.20 | 8 | 12.31 | 2014 | 198 | 0.43 / 401.28 | 2 | 2 |
3 | 7 | 2010.44 | 51 | 11.34 | 3304 | 1911 | 2.34 / 403.19 | 2 | 2 |
4 | 13 | 1854.68 | 37 | 12.30 | 3082 | 1403 | 3.74 / 404.60 | 2 | 2 |
5 | 13 | 753.44 | 37 | 13.36 | 1447 | 715 | 4.46 / 405.31 | 2 | 4 |
6 | 13 | 46.00 | 6 | 14.10 | 476 | 40 | 4.50 / 405.35 | 2 | 4 |
7 | 13 | 43.04 | 6 | 14.07 | 466 | 39 | 4.54 / 405.39 | 2 | 4 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 29 | 13.99 | 560 | 227 | 0.23 / 396.73 | 2 | 3 |
2 | 12 | 1119.08 | 8 | 12.27 | 2052 | 201 | 0.43 / 396.93 | 2 | 2 |
3 | 7 | 2010.92 | 50 | 11.35 | 3309 | 1878 | 2.31 / 398.81 | 2 | 2 |
4 | 13 | 1703.16 | 37 | 12.47 | 2869 | 1324 | 3.63 / 400.14 | 2 | 3 |
5 | 13 | 768.80 | 37 | 13.37 | 1449 | 717 | 4.35 / 400.85 | 2 | 4 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 31 | 13.98 | 559 | 242 | 0.24 / 392.38 | 2 | 3 |
2 | 3 | 948.76 | -1 | 13.98 | 559 | 0 | 0.00 / 392.38 | 2 | 3 |
3 | 12 | 1116.28 | 8 | 12.37 | 2017 | 200 | 0.44 / 392.58 | 2 | 2 |
4 | 7 | 2010.20 | 50 | 11.41 | 3304 | 1885 | 2.33 / 394.46 | 2 | 2 |
5 | 13 | 1697.48 | 37 | 12.49 | 2851 | 1318 | 3.64 / 395.78 | 2 | 3 |
6 | 13 | 772.28 | 37 | 13.36 | 1471 | 727 | 4.37 / 396.51 | 2 | 4 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 30 | 13.99 | 553 | 232 | 0.23 / 387.76 | 2 | 3 |
2 | 3 | 1026.88 | 1 | 12.82 | 1941 | 25 | 0.26 / 387.78 | 2 | 2 |
3 | 12 | 1144.76 | 8 | 12.43 | 2023 | 201 | 0.46 / 387.99 | 2 | 2 |
4 | 7 | 2002.12 | 50 | 11.47 | 3285 | 1884 | 2.34 / 389.87 | 2 | 2 |
5 | 13 | 1844.84 | 37 | 12.33 | 3062 | 1397 | 3.74 / 391.27 | 2 | 2 |
6 | 13 | 871.68 | 37 | 13.27 | 1605 | 788 | 4.53 / 392.05 | 2 | 4 |
7 | 13 | 44.28 | 6 | 14.10 | 475 | 40 | 4.57 / 392.09 | 2 | 4 |
8 | 13 | 41.40 | 6 | 14.08 | 461 | 39 | 4.61 / 392.13 | 2 | 4 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 27 | 13.99 | 554 | 209 | 0.21 / 383.10 | 2 | 3 |
2 | 10 | 1020.84 | 3 | 13.65 | 1910 | 78 | 0.29 / 383.18 | 2 | 4 |
3 | 12 | 1134.92 | 8 | 12.40 | 2036 | 202 | 0.49 / 383.38 | 2 | 2 |
4 | 7 | 2002.56 | 51 | 11.43 | 3306 | 1927 | 2.42 / 385.31 | 2 | 2 |
5 | 13 | 1845.64 | 37 | 12.33 | 3079 | 1405 | 3.82 / 386.71 | 2 | 2 |
6 | 13 | 731.44 | 37 | 13.41 | 1402 | 696 | 4.52 / 387.41 | 2 | 4 |
7 | 13 | 83.24 | 6 | 14.08 | 514 | 43 | 4.56 / 387.45 | 2 | 4 |
8 | 13 | 45.56 | 6 | 14.12 | 464 | 39 | 4.60 / 387.49 | 2 | 4 |
9 | 13 | 42.92 | 6 | 14.06 | 467 | 39 | 4.64 / 387.53 | 2 | 4 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 38 | 13.97 | 558 | 296 | 0.30 / 378.64 | 2 | 3 |
2 | 3 | 705.52 | -6 | 13.97 | 558 | 0 | 0.00 / 378.64 | 2 | 3 |
3 | 3 | 898.04 | -2 | 13.97 | 558 | 0 | 0.00 / 378.64 | 2 | 3 |
4 | 12 | 1096.00 | 8 | 12.39 | 2000 | 198 | 0.49 / 378.84 | 2 | 2 |
5 | 7 | 2003.32 | 50 | 11.42 | 3297 | 1883 | 2.38 / 380.72 | 2 | 2 |
6 | 13 | 1860.12 | 37 | 12.34 | 3105 | 1418 | 3.79 / 382.14 | 2 | 3 |
7 | 13 | 740.56 | 37 | 13.39 | 1425 | 706 | 4.50 / 382.85 | 2 | 5 |
8 | 13 | 66.48 | 6 | 14.11 | 497 | 42 | 4.54 / 382.89 | 2 | 4 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 38 | 13.90 | 562 | 297 | 0.30 / 374.14 | 2 | 3 |
2 | 12 | 1124.60 | 8 | 12.35 | 2066 | 204 | 0.50 / 374.35 | 2 | 2 |
3 | 7 | 2012.12 | 50 | 11.42 | 3307 | 1888 | 2.39 / 376.24 | 2 | 2 |
4 | 13 | 1853.96 | 37 | 12.35 | 3094 | 1414 | 3.80 / 377.65 | 2 | 3 |
5 | 13 | 727.40 | 37 | 13.42 | 1399 | 695 | 4.50 / 378.35 | 2 | 4 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 37 | 13.96 | 555 | 287 | 0.29 / 368.61 | 2 | 3 |
2 | 12 | 1142.28 | 8 | 12.34 | 2073 | 205 | 0.49 / 368.81 | 2 | 2 |
3 | 7 | 2012.92 | 50 | 11.46 | 3304 | 1893 | 2.38 / 370.71 | 2 | 2 |
4 | 13 | 1855.80 | 37 | 12.35 | 3107 | 1420 | 3.80 / 372.13 | 2 | 3 |
5 | 13 | 699.60 | 37 | 13.44 | 1361 | 677 | 4.48 / 372.80 | 2 | 4 |
6 | 8 | 0.40 | 190 | 13.85 | 397 | 1045 | 5.53 / 373.85 | 2 | 20 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 39 | 13.95 | 561 | 305 | 0.31 / 362.99 | 2 | 3 |
2 | 3 | 953.08 | -1 | 13.95 | 561 | 0 | 0.00 / 362.99 | 2 | 3 |
3 | 12 | 1133.20 | 8 | 12.40 | 2060 | 204 | 0.51 / 363.19 | 2 | 2 |
4 | 7 | 2001.56 | 51 | 11.43 | 3308 | 1928 | 2.44 / 365.12 | 2 | 2 |
5 | 13 | 1849.40 | 37 | 12.37 | 3089 | 1414 | 3.85 / 366.53 | 2 | 3 |
6 | 13 | 692.24 | 37 | 13.47 | 1347 | 671 | 4.52 / 367.20 | 2 | 4 |
7 | 13 | 47.64 | 6 | 14.12 | 476 | 40 | 4.56 / 367.24 | 2 | 4 |
8 | 13 | 44.28 | 6 | 14.09 | 469 | 40 | 4.60 / 367.28 | 2 | 4 |
9 | 8 | -0.08 | 190 | 13.87 | 394 | 1038 | 5.64 / 368.32 | 2 | 21 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 39 | 13.96 | 554 | 302 | 0.30 / 357.40 | 2 | 3 |
2 | 12 | 1117.36 | 8 | 12.39 | 2007 | 199 | 0.50 / 357.60 | 2 | 2 |
3 | 7 | 2006.96 | 50 | 11.42 | 3319 | 1895 | 2.40 / 359.49 | 2 | 2 |
4 | 13 | 1848.48 | 37 | 12.38 | 3077 | 1409 | 3.81 / 360.90 | 2 | 3 |
5 | 13 | 723.80 | 37 | 13.43 | 1403 | 697 | 4.50 / 361.60 | 2 | 4 |
6 | 13 | 61.56 | 6 | 14.13 | 485 | 41 | 4.54 / 361.64 | 2 | 4 |
7 | 8 | 0.56 | 190 | 13.87 | 394 | 1038 | 5.58 / 362.68 | 2 | 23 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 39 | 13.97 | 564 | 307 | 0.31 / 351.82 | 2 | 3 |
2 | 12 | 1122.52 | 8 | 12.35 | 2048 | 202 | 0.51 / 352.02 | 2 | 2 |
3 | 7 | 2011.28 | 50 | 11.43 | 3311 | 1892 | 2.40 / 353.92 | 2 | 2 |
4 | 13 | 1858.96 | 37 | 12.39 | 3086 | 1415 | 3.82 / 355.33 | 2 | 3 |
5 | 13 | 712.36 | 37 | 13.45 | 1378 | 686 | 4.50 / 356.02 | 2 | 5 |
6 | 13 | 76.76 | 6 | 14.12 | 509 | 43 | 4.55 / 356.06 | 2 | 4 |
7 | 8 | -0.16 | 190 | 13.88 | 394 | 1039 | 5.58 / 357.10 | 2 | 18 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 39 | 13.95 | 553 | 301 | 0.30 / 346.06 | 2 | 3 |
2 | 12 | 1125.96 | 8 | 12.34 | 2031 | 201 | 0.50 / 346.26 | 2 | 2 |
3 | 7 | 2005.76 | 51 | 11.40 | 3300 | 1919 | 2.42 / 348.17 | 2 | 2 |
4 | 13 | 1847.08 | 37 | 12.38 | 3081 | 1411 | 3.83 / 349.59 | 2 | 3 |
5 | 13 | 718.04 | 37 | 13.46 | 1380 | 687 | 4.52 / 350.27 | 2 | 4 |
6 | 13 | 17.08 | 37 | 14.12 | 420 | 219 | 4.74 / 350.49 | 2 | 5 |
7 | 8 | 0.24 | 190 | 13.73 | 392 | 1023 | 5.76 / 351.51 | 2 | 22 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 38 | 14.00 | 553 | 294 | 0.29 / 340.68 | 2 | 3 |
2 | 12 | 1147.08 | 8 | 12.42 | 2053 | 204 | 0.50 / 340.88 | 2 | 2 |
3 | 7 | 2008.80 | 50 | 11.43 | 3314 | 1894 | 2.39 / 342.78 | 2 | 2 |
4 | 13 | 1694.76 | 37 | 12.59 | 2858 | 1331 | 3.72 / 344.11 | 2 | 3 |
5 | 13 | 590.08 | 37 | 13.58 | 1198 | 602 | 4.33 / 344.71 | 2 | 4 |
6 | 8 | 0.44 | 190 | 13.88 | 396 | 1044 | 5.37 / 345.75 | 2 | 17 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 38 | 14.00 | 555 | 295 | 0.30 / 335.33 | 2 | 3 |
2 | 12 | 1139.24 | 8 | 12.29 | 2051 | 202 | 0.50 / 335.53 | 2 | 2 |
3 | 7 | 2007.56 | 50 | 11.39 | 3319 | 1890 | 2.39 / 337.42 | 2 | 2 |
4 | 13 | 1690.80 | 37 | 12.58 | 2854 | 1328 | 3.72 / 338.75 | 2 | 3 |
5 | 13 | 575.40 | 37 | 13.61 | 1169 | 589 | 4.30 / 339.34 | 2 | 4 |
6 | 8 | -0.28 | 190 | 13.88 | 396 | 1044 | 5.35 / 340.38 | 2 | 23 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 38 | 14.01 | 531 | 283 | 0.28 / 330.03 | 2 | 3 |
2 | 12 | 1150.36 | 8 | 12.31 | 2049 | 202 | 0.48 / 330.23 | 2 | 2 |
3 | 7 | 2001.00 | 50 | 11.43 | 3292 | 1881 | 2.37 / 332.11 | 2 | 2 |
4 | 13 | 1681.56 | 37 | 12.62 | 2824 | 1319 | 3.68 / 333.43 | 2 | 3 |
5 | 13 | 549.64 | 37 | 13.64 | 1134 | 572 | 4.26 / 334.01 | 2 | 5 |
6 | 8 | 0.32 | 190 | 13.90 | 390 | 1030 | 5.29 / 335.04 | 2 | 17 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 38 | 14.03 | 537 | 286 | 0.29 / 324.57 | 2 | 3 |
2 | 12 | 1122.24 | 8 | 12.28 | 2036 | 200 | 0.49 / 324.77 | 2 | 2 |
3 | 7 | 2005.80 | 51 | 11.40 | 3304 | 1921 | 2.41 / 326.69 | 2 | 2 |
4 | 13 | 1686.00 | 37 | 12.62 | 2837 | 1325 | 3.73 / 328.02 | 2 | 3 |
5 | 13 | 726.52 | 37 | 13.50 | 1387 | 693 | 4.42 / 328.71 | 2 | 4 |
6 | 8 | 0.04 | 190 | 13.89 | 394 | 1040 | 5.46 / 329.75 | 2 | 20 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 37 | 14.01 | 568 | 294 | 0.29 / 319.04 | 2 | 3 |
2 | 12 | 1139.08 | 8 | 12.36 | 2063 | 204 | 0.50 / 319.25 | 2 | 2 |
3 | 7 | 2001.16 | 50 | 11.52 | 3292 | 1896 | 2.39 / 321.14 | 2 | 2 |
4 | 13 | 1689.96 | 37 | 12.63 | 2842 | 1328 | 3.72 / 322.47 | 2 | 3 |
5 | 13 | 714.20 | 37 | 13.51 | 1378 | 689 | 4.41 / 323.16 | 2 | 4 |
6 | 13 | 43.84 | 6 | 14.15 | 472 | 40 | 4.45 / 323.20 | 2 | 4 |
7 | 13 | 40.88 | 6 | 14.16 | 466 | 40 | 4.49 / 323.24 | 2 | 4 |
8 | 8 | 0.32 | 190 | 13.90 | 396 | 1046 | 5.54 / 324.28 | 2 | 17 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 37 | 14.01 | 551 | 286 | 0.29 / 313.56 | 2 | 3 |
2 | 12 | 1141.16 | 8 | 12.31 | 2048 | 202 | 0.49 / 313.76 | 2 | 2 |
3 | 7 | 2007.92 | 51 | 11.48 | 3300 | 1932 | 2.42 / 315.69 | 2 | 2 |
4 | 13 | 1697.72 | 37 | 12.64 | 2862 | 1339 | 3.76 / 317.03 | 2 | 3 |
5 | 13 | 582.52 | 37 | 13.62 | 1202 | 606 | 4.36 / 317.64 | 2 | 4 |
6 | 13 | 50.64 | 6 | 14.15 | 477 | 40 | 4.40 / 317.68 | 2 | 4 |
7 | 8 | 0.00 | 190 | 13.89 | 405 | 1069 | 5.47 / 318.75 | 2 | 19 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 38 | 14.03 | 551 | 294 | 0.29 / 307.69 | 2 | 3 |
2 | 3 | 972.64 | -1 | 14.03 | 551 | 0 | 0.00 / 307.69 | 2 | 3 |
3 | 12 | 1152.60 | 8 | 12.33 | 2080 | 205 | 0.50 / 307.89 | 2 | 2 |
4 | 7 | 2003.56 | 51 | 11.51 | 3297 | 1935 | 2.43 / 309.83 | 2 | 2 |
5 | 13 | 1693.96 | 37 | 12.65 | 2851 | 1334 | 3.77 / 311.16 | 2 | 3 |
6 | 13 | 562.88 | 37 | 13.66 | 1150 | 581 | 4.35 / 311.75 | 2 | 4 |
7 | 13 | 48.72 | 6 | 14.13 | 476 | 40 | 4.39 / 311.79 | 2 | 4 |
8 | 13 | 45.48 | 6 | 14.10 | 474 | 40 | 4.43 / 311.83 | 2 | 4 |
9 | 13 | 18.60 | 37 | 14.10 | 424 | 221 | 4.65 / 312.05 | 2 | 6 |
10 | 13 | 10.44 | 37 | 13.95 | 412 | 213 | 4.86 / 312.26 | 2 | 9 |
11 | 8 | 0.48 | 190 | 13.66 | 391 | 1015 | 5.88 / 313.27 | 2 | 30 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 38 | 14.04 | 555 | 296 | 0.30 / 302.13 | 2 | 3 |
2 | 12 | 1123.80 | 8 | 12.36 | 2039 | 202 | 0.50 / 302.33 | 2 | 2 |
3 | 7 | 2006.00 | 51 | 11.54 | 3288 | 1935 | 2.43 / 304.27 | 2 | 2 |
4 | 13 | 1674.04 | 37 | 12.67 | 2821 | 1322 | 3.76 / 305.59 | 2 | 3 |
5 | 13 | 546.76 | 37 | 13.68 | 1122 | 568 | 4.32 / 306.16 | 2 | 4 |
6 | 13 | 18.20 | 37 | 14.15 | 425 | 223 | 4.55 / 306.38 | 2 | 5 |
7 | 8 | -0.16 | 190 | 13.77 | 388 | 1015 | 5.56 / 307.40 | 2 | 23 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 37 | 14.02 | 545 | 283 | 0.28 / 296.76 | 2 | 3 |
2 | 3 | 1019.48 | 1 | 13.11 | 1962 | 26 | 0.31 / 296.79 | 2 | 2 |
3 | 12 | 1140.72 | 8 | 12.41 | 2050 | 204 | 0.51 / 296.99 | 2 | 2 |
4 | 7 | 2002.80 | 51 | 11.62 | 3283 | 1946 | 2.46 / 298.94 | 2 | 2 |
5 | 13 | 1516.80 | 37 | 12.83 | 2573 | 1221 | 3.68 / 300.16 | 2 | 3 |
6 | 13 | 584.28 | 37 | 13.66 | 1179 | 596 | 4.27 / 300.76 | 2 | 4 |
7 | 13 | 49.52 | 6 | 14.16 | 466 | 40 | 4.31 / 300.80 | 2 | 4 |
8 | 8 | 0.16 | 190 | 13.92 | 393 | 1039 | 5.35 / 301.83 | 2 | 24 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 36 | 14.02 | 539 | 272 | 0.27 / 291.42 | 2 | 4 |
2 | 3 | 1042.04 | 1 | 13.80 | 1971 | 27 | 0.30 / 291.44 | 2 | 3 |
3 | 3 | 1018.64 | 1 | 13.08 | 1933 | 25 | 0.32 / 291.47 | 2 | 2 |
4 | 12 | 1134.24 | 4 | 12.52 | 2019 | 101 | 0.43 / 291.57 | 2 | 2 |
5 | 7 | 2002.84 | 51 | 11.55 | 3287 | 1936 | 2.36 / 293.51 | 2 | 2 |
6 | 13 | 1701.60 | 31 | 12.83 | 2840 | 1130 | 3.49 / 294.64 | 2 | 3 |
7 | 13 | 847.36 | 31 | 13.50 | 1589 | 665 | 4.16 / 295.30 | 2 | 4 |
8 | 13 | 83.36 | 6 | 14.15 | 517 | 44 | 4.20 / 295.35 | 2 | 4 |
9 | 13 | 64.32 | 6 | 14.11 | 499 | 42 | 4.24 / 295.39 | 2 | 4 |
10 | 13 | 52.40 | 6 | 14.10 | 482 | 41 | 4.28 / 295.43 | 2 | 4 |
11 | 8 | 0.20 | 190 | 13.91 | 398 | 1052 | 5.34 / 296.48 | 2 | 21 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 27 | 14.09 | 544 | 207 | 0.21 / 285.75 | 2 | 3 |
2 | 10 | 1061.36 | 5 | 14.05 | 1895 | 133 | 0.34 / 285.89 | 2 | 4 |
3 | 3 | 1158.36 | 4 | 13.98 | 2087 | 117 | 0.46 / 286.00 | 2 | 3 |
4 | 3 | 1022.92 | 1 | 13.84 | 1932 | 27 | 0.48 / 286.03 | 2 | 2 |
5 | 12 | 1132.80 | 4 | 12.45 | 2035 | 101 | 0.58 / 286.13 | 2 | 2 |
6 | 7 | 2000.92 | 50 | 11.58 | 3283 | 1901 | 2.49 / 288.03 | 2 | 2 |
7 | 13 | 1849.56 | 31 | 12.70 | 3076 | 1211 | 3.70 / 289.24 | 2 | 3 |
8 | 13 | 765.88 | 31 | 13.59 | 1437 | 605 | 4.30 / 289.85 | 2 | 4 |
9 | 13 | 110.84 | 6 | 14.17 | 537 | 46 | 4.35 / 289.89 | 2 | 4 |
10 | 13 | 57.04 | 6 | 14.14 | 476 | 40 | 4.39 / 289.93 | 2 | 4 |
11 | 13 | 18.52 | 31 | 14.17 | 423 | 186 | 4.57 / 290.12 | 2 | 5 |
12 | 8 | 0.20 | 190 | 13.85 | 390 | 1026 | 5.60 / 291.15 | 2 | 24 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 27 | 14.12 | 554 | 211 | 0.21 / 280.36 | 2 | 3 |
2 | 12 | 1125.68 | 4 | 12.52 | 2037 | 102 | 0.31 / 280.46 | 2 | 2 |
3 | 7 | 2012.64 | 50 | 11.53 | 3302 | 1904 | 2.22 / 282.36 | 2 | 2 |
4 | 13 | 1857.04 | 31 | 12.67 | 3087 | 1212 | 3.43 / 283.58 | 2 | 3 |
5 | 13 | 787.16 | 31 | 13.55 | 1480 | 622 | 4.05 / 284.20 | 2 | 4 |
6 | 13 | 123.28 | 6 | 14.14 | 571 | 48 | 4.10 / 284.25 | 2 | 4 |
7 | 13 | 82.16 | 6 | 14.13 | 515 | 44 | 4.14 / 284.29 | 2 | 4 |
8 | 13 | 45.24 | 6 | 14.15 | 474 | 40 | 4.18 / 284.33 | 2 | 4 |
9 | 13 | 6.40 | 31 | 14.16 | 415 | 182 | 4.37 / 284.51 | 2 | 5 |
10 | 8 | 0.24 | 190 | 13.81 | 394 | 1034 | 5.40 / 285.55 | 2 | 24 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 27 | 14.11 | 564 | 215 | 0.21 / 276.23 | 2 | 3 |
2 | 12 | 1125.20 | 4 | 12.53 | 2046 | 103 | 0.32 / 276.33 | 2 | 2 |
3 | 7 | 2001.56 | 50 | 11.56 | 3296 | 1905 | 2.22 / 278.24 | 2 | 2 |
4 | 13 | 1844.64 | 31 | 12.69 | 3072 | 1208 | 3.43 / 279.45 | 2 | 3 |
5 | 13 | 766.84 | 31 | 13.57 | 1473 | 620 | 4.05 / 280.06 | 2 | 4 |
6 | 13 | 58.68 | 6 | 14.17 | 482 | 41 | 4.09 / 280.11 | 2 | 4 |
7 | 13 | 50.12 | 6 | 14.14 | 475 | 40 | 4.13 / 280.15 | 2 | 4 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 27 | 14.12 | 566 | 216 | 0.22 / 272.00 | 2 | 3 |
2 | 12 | 1137.28 | 4 | 12.61 | 2048 | 103 | 0.32 / 272.11 | 2 | 2 |
3 | 7 | 2001.08 | 50 | 11.60 | 3287 | 1906 | 2.23 / 274.01 | 2 | 2 |
4 | 13 | 1844.36 | 31 | 12.70 | 3092 | 1217 | 3.44 / 275.23 | 2 | 3 |
5 | 13 | 907.00 | 31 | 13.50 | 1663 | 696 | 4.14 / 275.93 | 2 | 4 |
6 | 13 | 100.24 | 6 | 14.15 | 549 | 47 | 4.19 / 275.97 | 2 | 4 |
7 | 13 | 44.08 | 6 | 14.15 | 472 | 40 | 4.23 / 276.01 | 2 | 4 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 27 | 14.16 | 551 | 211 | 0.21 / 267.71 | 2 | 3 |
2 | 12 | 1126.92 | 4 | 12.64 | 2052 | 104 | 0.31 / 267.81 | 2 | 2 |
3 | 7 | 2001.56 | 51 | 11.64 | 3301 | 1960 | 2.27 / 269.77 | 2 | 2 |
4 | 13 | 1846.00 | 31 | 12.71 | 3076 | 1212 | 3.49 / 270.98 | 2 | 3 |
5 | 13 | 934.64 | 31 | 13.46 | 1718 | 717 | 4.20 / 271.70 | 2 | 4 |
6 | 13 | 105.60 | 6 | 14.14 | 550 | 47 | 4.25 / 271.75 | 2 | 4 |
7 | 13 | 73.88 | 6 | 14.15 | 502 | 43 | 4.29 / 271.79 | 2 | 4 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 27 | 14.12 | 562 | 214 | 0.21 / 263.32 | 2 | 3 |
2 | 12 | 1126.08 | 4 | 12.68 | 2040 | 103 | 0.32 / 263.42 | 2 | 2 |
3 | 7 | 2003.12 | 51 | 11.66 | 3299 | 1962 | 2.28 / 265.38 | 2 | 2 |
4 | 13 | 1856.84 | 31 | 12.72 | 3091 | 1219 | 3.50 / 266.60 | 2 | 3 |
5 | 13 | 1084.64 | 31 | 13.35 | 1955 | 809 | 4.31 / 267.41 | 2 | 4 |
6 | 13 | 89.48 | 6 | 14.13 | 532 | 45 | 4.35 / 267.45 | 2 | 4 |
7 | 13 | 67.60 | 6 | 14.14 | 503 | 43 | 4.40 / 267.50 | 2 | 4 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 26 | 14.17 | 553 | 204 | 0.20 / 258.96 | 2 | 3 |
2 | 3 | 1020.28 | 1 | 13.49 | 1949 | 26 | 0.23 / 258.99 | 2 | 2 |
3 | 3 | 1020.08 | 1 | 13.45 | 1952 | 26 | 0.26 / 259.02 | 2 | 2 |
4 | 12 | 1130.48 | 4 | 12.72 | 2044 | 104 | 0.36 / 259.12 | 2 | 2 |
5 | 7 | 2002.12 | 51 | 11.72 | 3316 | 1982 | 2.34 / 261.10 | 2 | 2 |
6 | 13 | 1846.72 | 31 | 12.75 | 3075 | 1215 | 3.56 / 262.32 | 2 | 3 |
7 | 13 | 907.52 | 31 | 13.50 | 1663 | 696 | 4.25 / 263.01 | 2 | 4 |
8 | 13 | 95.72 | 6 | 14.16 | 534 | 45 | 4.30 / 263.06 | 2 | 4 |
9 | 13 | 69.16 | 6 | 14.13 | 502 | 43 | 4.34 / 263.10 | 2 | 4 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 26 | 14.15 | 545 | 201 | 0.20 / 254.71 | 2 | 3 |
2 | 12 | 1147.60 | 4 | 12.73 | 2102 | 107 | 0.31 / 254.82 | 2 | 2 |
3 | 7 | 2002.40 | 50 | 11.73 | 3320 | 1947 | 2.25 / 256.77 | 2 | 2 |
4 | 13 | 1847.64 | 31 | 12.75 | 3080 | 1217 | 3.47 / 257.99 | 2 | 3 |
5 | 13 | 900.84 | 31 | 13.51 | 1649 | 691 | 4.16 / 258.68 | 2 | 4 |
6 | 13 | 97.04 | 6 | 14.15 | 520 | 44 | 4.21 / 258.72 | 2 | 4 |
7 | 13 | 54.16 | 6 | 14.13 | 469 | 40 | 4.25 / 258.76 | 2 | 4 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 25 | 14.13 | 562 | 199 | 0.20 / 250.59 | 2 | 4 |
2 | 12 | 1148.04 | 4 | 12.77 | 2085 | 107 | 0.31 / 250.70 | 2 | 2 |
3 | 7 | 2007.28 | 50 | 11.78 | 3312 | 1951 | 2.26 / 252.65 | 2 | 2 |
4 | 13 | 1848.28 | 31 | 12.75 | 3093 | 1223 | 3.48 / 253.87 | 2 | 3 |
5 | 13 | 736.00 | 31 | 13.64 | 1407 | 595 | 4.07 / 254.47 | 2 | 4 |
6 | 13 | 103.12 | 6 | 14.15 | 539 | 46 | 4.12 / 254.51 | 2 | 4 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 30 | 14.10 | 557 | 236 | 0.24 / 246.54 | 2 | 3 |
2 | 3 | 836.76 | -3 | 14.10 | 557 | 0 | 0.00 / 246.54 | 2 | 3 |
3 | 3 | 941.76 | -1 | 14.10 | 557 | 0 | 0.00 / 246.54 | 2 | 3 |
4 | 12 | 1095.00 | 4 | 12.86 | 2018 | 104 | 0.34 / 246.65 | 2 | 2 |
5 | 7 | 2008.04 | 50 | 11.78 | 3311 | 1950 | 2.29 / 248.60 | 2 | 2 |
6 | 13 | 1677.04 | 31 | 12.93 | 2836 | 1137 | 3.43 / 249.73 | 2 | 3 |
7 | 13 | 768.12 | 31 | 13.61 | 1456 | 614 | 4.04 / 250.35 | 2 | 4 |
8 | 13 | 108.44 | 6 | 14.15 | 545 | 46 | 4.09 / 250.39 | 2 | 4 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 26 | 14.13 | 543 | 199 | 0.20 / 242.22 | 2 | 3 |
2 | 10 | 1029.32 | 3 | 14.12 | 1897 | 80 | 0.28 / 242.30 | 2 | 4 |
3 | 3 | 1053.40 | 1 | 14.05 | 1925 | 27 | 0.31 / 242.32 | 2 | 3 |
4 | 12 | 1128.04 | 4 | 12.86 | 2045 | 105 | 0.41 / 242.43 | 2 | 2 |
5 | 7 | 2010.56 | 51 | 11.85 | 3307 | 1999 | 2.41 / 244.43 | 2 | 2 |
6 | 13 | 1851.96 | 31 | 12.77 | 3093 | 1224 | 3.64 / 245.65 | 2 | 3 |
7 | 13 | 760.56 | 31 | 13.61 | 1459 | 616 | 4.25 / 246.27 | 2 | 5 |
8 | 13 | 57.76 | 6 | 14.15 | 479 | 41 | 4.29 / 246.31 | 2 | 4 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 25 | 14.12 | 578 | 204 | 0.20 / 238.00 | 2 | 4 |
2 | 12 | 1132.56 | 4 | 12.87 | 2061 | 106 | 0.31 / 238.11 | 2 | 2 |
3 | 7 | 2003.52 | 50 | 11.82 | 3313 | 1958 | 2.27 / 240.07 | 2 | 2 |
4 | 13 | 1697.00 | 31 | 12.90 | 2875 | 1150 | 3.42 / 241.22 | 2 | 3 |
5 | 13 | 936.72 | 31 | 13.48 | 1715 | 717 | 4.13 / 241.93 | 2 | 4 |
6 | 13 | 70.68 | 6 | 14.13 | 503 | 43 | 4.18 / 241.97 | 2 | 4 |
7 | 13 | 56.32 | 6 | 14.14 | 484 | 41 | 4.22 / 242.02 | 2 | 4 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 25 | 14.14 | 569 | 201 | 0.20 / 233.88 | 2 | 4 |
2 | 12 | 1119.40 | 4 | 12.90 | 2054 | 106 | 0.31 / 233.99 | 2 | 2 |
3 | 7 | 2007.00 | 50 | 11.84 | 3305 | 1957 | 2.26 / 235.94 | 2 | 2 |
4 | 13 | 1689.72 | 31 | 12.91 | 2849 | 1140 | 3.40 / 237.08 | 2 | 3 |
5 | 13 | 765.28 | 31 | 13.59 | 1482 | 624 | 4.03 / 237.71 | 2 | 5 |
6 | 13 | 106.04 | 6 | 14.16 | 545 | 46 | 4.07 / 237.75 | 2 | 4 |
7 | 13 | 75.64 | 6 | 14.13 | 511 | 43 | 4.12 / 237.80 | 2 | 4 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 25 | 14.13 | 559 | 197 | 0.20 / 229.94 | 2 | 3 |
2 | 12 | 1125.56 | 4 | 12.83 | 2042 | 105 | 0.30 / 230.04 | 2 | 2 |
3 | 7 | 2001.72 | 50 | 11.88 | 3310 | 1966 | 2.27 / 232.01 | 2 | 2 |
4 | 13 | 1682.76 | 31 | 12.91 | 2843 | 1138 | 3.41 / 233.15 | 2 | 3 |
5 | 13 | 621.32 | 31 | 13.71 | 1252 | 532 | 3.94 / 233.68 | 2 | 5 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 25 | 14.15 | 563 | 199 | 0.20 / 225.81 | 2 | 3 |
2 | 12 | 1130.24 | 4 | 12.87 | 2038 | 105 | 0.30 / 225.91 | 2 | 2 |
3 | 7 | 2001.88 | 50 | 11.90 | 3310 | 1969 | 2.27 / 227.88 | 2 | 2 |
4 | 13 | 1842.20 | 31 | 12.75 | 3090 | 1221 | 3.49 / 229.10 | 2 | 3 |
5 | 13 | 727.48 | 31 | 13.62 | 1407 | 594 | 4.09 / 229.70 | 2 | 5 |
6 | 13 | 68.80 | 6 | 14.14 | 503 | 43 | 4.13 / 229.74 | 2 | 4 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 24 | 14.14 | 569 | 193 | 0.19 / 221.73 | 2 | 4 |
2 | 3 | 1046.76 | 1 | 14.10 | 1949 | 27 | 0.22 / 221.76 | 2 | 3 |
3 | 12 | 1130.76 | 4 | 12.85 | 2059 | 106 | 0.33 / 221.87 | 2 | 2 |
4 | 7 | 2008.16 | 50 | 11.95 | 3311 | 1978 | 2.30 / 223.85 | 2 | 2 |
5 | 13 | 1691.92 | 31 | 12.90 | 2866 | 1146 | 3.45 / 224.99 | 2 | 4 |
6 | 13 | 758.20 | 31 | 13.61 | 1463 | 617 | 4.07 / 225.61 | 2 | 5 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 36 | 14.09 | 556 | 282 | 0.28 / 217.55 | 2 | 3 |
2 | 3 | 668.76 | -6 | 14.09 | 556 | 0 | 0.00 / 217.55 | 2 | 3 |
3 | 3 | 840.32 | -3 | 14.09 | 556 | 0 | 0.00 / 217.55 | 2 | 3 |
4 | 12 | 1091.64 | 4 | 12.88 | 1985 | 102 | 0.38 / 217.65 | 2 | 2 |
5 | 7 | 2001.88 | 50 | 11.98 | 3293 | 1973 | 2.36 / 219.62 | 2 | 2 |
6 | 13 | 1842.24 | 31 | 12.74 | 3088 | 1220 | 3.58 / 220.84 | 2 | 3 |
7 | 13 | 754.08 | 31 | 13.61 | 1464 | 618 | 4.19 / 221.46 | 2 | 4 |
8 | 13 | 43.92 | 6 | 14.19 | 472 | 40 | 4.23 / 221.50 | 2 | 4 |
9 | 13 | 40.92 | 6 | 14.19 | 471 | 40 | 4.27 / 221.54 | 2 | 5 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 35 | 14.05 | 558 | 274 | 0.27 / 213.34 | 2 | 4 |
2 | 12 | 1128.08 | 4 | 12.93 | 2044 | 106 | 0.38 / 213.44 | 2 | 2 |
3 | 7 | 2003.16 | 51 | 12.00 | 3295 | 2017 | 2.40 / 215.46 | 2 | 2 |
4 | 13 | 1688.00 | 31 | 12.91 | 2856 | 1143 | 3.54 / 216.60 | 2 | 3 |
5 | 13 | 765.20 | 31 | 13.61 | 1463 | 617 | 4.16 / 217.22 | 2 | 4 |
6 | 13 | 98.44 | 6 | 14.13 | 544 | 46 | 4.20 / 217.27 | 2 | 4 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 35 | 14.05 | 565 | 278 | 0.28 / 208.15 | 2 | 4 |
2 | 12 | 1111.08 | 4 | 12.93 | 1986 | 103 | 0.38 / 208.25 | 2 | 2 |
3 | 7 | 2002.72 | 51 | 12.03 | 3290 | 2019 | 2.40 / 210.27 | 2 | 2 |
4 | 13 | 1675.24 | 31 | 12.93 | 2831 | 1135 | 3.53 / 211.40 | 2 | 3 |
5 | 13 | 598.08 | 31 | 13.73 | 1228 | 523 | 4.06 / 211.93 | 2 | 5 |
6 | 13 | 48.08 | 6 | 14.17 | 470 | 40 | 4.10 / 211.97 | 2 | 4 |
7 | 13 | 44.32 | 6 | 14.22 | 473 | 40 | 4.14 / 212.01 | 2 | 5 |
8 | 8 | -0.32 | 190 | 13.94 | 399 | 1057 | 5.19 / 213.06 | 2 | 21 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 35 | 14.12 | 557 | 275 | 0.28 / 203.10 | 2 | 4 |
2 | 12 | 1128.52 | 4 | 12.93 | 2045 | 106 | 0.38 / 203.20 | 2 | 2 |
3 | 7 | 2011.40 | 50 | 12.10 | 3294 | 1993 | 2.37 / 205.19 | 2 | 2 |
4 | 13 | 1527.48 | 31 | 13.04 | 2599 | 1051 | 3.42 / 206.24 | 2 | 4 |
5 | 13 | 611.16 | 31 | 13.73 | 1244 | 529 | 3.95 / 206.77 | 2 | 5 |
6 | 13 | 58.32 | 6 | 14.17 | 488 | 41 | 4.00 / 206.82 | 2 | 4 |
7 | 8 | 1.16 | 190 | 13.95 | 398 | 1055 | 5.05 / 207.87 | 2 | 21 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 35 | 14.14 | 534 | 264 | 0.26 / 197.98 | 2 | 3 |
2 | 12 | 1117.24 | 4 | 12.93 | 2043 | 106 | 0.37 / 198.09 | 2 | 2 |
3 | 7 | 2004.44 | 50 | 12.14 | 3306 | 2007 | 2.38 / 200.09 | 2 | 2 |
4 | 13 | 1683.12 | 31 | 12.94 | 2818 | 1130 | 3.51 / 201.22 | 2 | 4 |
5 | 13 | 585.96 | 31 | 13.77 | 1196 | 511 | 4.02 / 201.73 | 2 | 5 |
6 | 13 | 47.92 | 6 | 14.16 | 475 | 40 | 4.06 / 201.77 | 2 | 4 |
7 | 8 | 1.32 | 190 | 13.95 | 395 | 1047 | 5.10 / 202.82 | 2 | 22 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 34 | 14.14 | 525 | 252 | 0.25 / 192.81 | 2 | 3 |
2 | 3 | 1026.52 | 1 | 14.11 | 1925 | 27 | 0.28 / 192.83 | 2 | 3 |
3 | 12 | 1131.00 | 4 | 13.05 | 2028 | 106 | 0.39 / 192.94 | 2 | 2 |
4 | 7 | 2006.04 | 51 | 12.20 | 3289 | 2046 | 2.43 / 194.98 | 2 | 2 |
5 | 13 | 1675.16 | 31 | 12.95 | 2823 | 1133 | 3.57 / 196.12 | 2 | 4 |
6 | 13 | 578.92 | 31 | 13.78 | 1189 | 508 | 4.07 / 196.63 | 2 | 5 |
7 | 13 | 54.24 | 6 | 14.18 | 474 | 40 | 4.11 / 196.67 | 2 | 4 |
8 | 8 | -0.16 | 190 | 13.98 | 395 | 1049 | 5.16 / 197.72 | 2 | 20 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 36 | 14.12 | 557 | 283 | 0.28 / 187.90 | 2 | 3 |
2 | 3 | 942.56 | -1 | 14.12 | 557 | 0 | 0.00 / 187.90 | 2 | 3 |
3 | 12 | 1113.04 | 4 | 13.02 | 2009 | 105 | 0.39 / 188.00 | 2 | 2 |
4 | 7 | 2005.76 | 50 | 12.22 | 3287 | 2008 | 2.40 / 190.01 | 2 | 2 |
5 | 13 | 1516.56 | 31 | 13.06 | 2592 | 1049 | 3.45 / 191.06 | 2 | 3 |
6 | 13 | 468.12 | 31 | 13.87 | 1037 | 446 | 3.89 / 191.50 | 2 | 5 |
7 | 8 | 0.44 | 190 | 14.00 | 394 | 1048 | 4.94 / 192.55 | 2 | 16 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 36 | 14.11 | 534 | 271 | 0.27 / 182.74 | 2 | 3 |
2 | 12 | 1123.28 | 4 | 13.12 | 2019 | 106 | 0.38 / 182.84 | 2 | 2 |
3 | 7 | 2003.04 | 50 | 12.27 | 3295 | 2021 | 2.40 / 184.86 | 2 | 2 |
4 | 13 | 1512.04 | 31 | 13.08 | 2580 | 1046 | 3.44 / 185.91 | 2 | 4 |
5 | 13 | 601.48 | 31 | 13.76 | 1235 | 527 | 3.97 / 186.44 | 2 | 4 |
6 | 13 | 47.12 | 6 | 14.19 | 478 | 41 | 4.01 / 186.48 | 2 | 4 |
7 | 13 | 44.40 | 6 | 14.25 | 474 | 41 | 4.05 / 186.52 | 2 | 5 |
8 | 13 | 42.16 | 6 | 14.26 | 464 | 40 | 4.09 / 186.56 | 2 | 5 |
9 | 8 | 0.08 | 190 | 13.97 | 398 | 1056 | 5.15 / 187.61 | 2 | 21 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 36 | 14.17 | 561 | 286 | 0.29 / 177.63 | 2 | 3 |
2 | 12 | 1108.24 | 4 | 13.19 | 2004 | 106 | 0.39 / 177.73 | 2 | 2 |
3 | 7 | 2002.16 | 50 | 12.33 | 3300 | 2034 | 2.43 / 179.77 | 2 | 2 |
4 | 13 | 1508.32 | 31 | 13.10 | 2580 | 1048 | 3.47 / 180.81 | 2 | 4 |
5 | 13 | 446.92 | 31 | 13.91 | 1008 | 435 | 3.91 / 181.25 | 2 | 5 |
6 | 13 | 6.36 | 31 | 14.27 | 409 | 181 | 4.09 / 181.43 | 2 | 4 |
7 | 8 | -0.04 | 190 | 13.94 | 391 | 1036 | 5.13 / 182.46 | 2 | 22 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 35 | 14.17 | 534 | 265 | 0.26 / 172.42 | 2 | 3 |
2 | 3 | 1022.88 | 1 | 14.15 | 1886 | 27 | 0.29 / 172.45 | 2 | 2 |
3 | 12 | 1139.00 | 4 | 13.20 | 2053 | 108 | 0.40 / 172.55 | 2 | 2 |
4 | 7 | 2004.72 | 50 | 12.37 | 3312 | 2048 | 2.45 / 174.60 | 2 | 2 |
5 | 13 | 1680.04 | 31 | 13.00 | 2817 | 1135 | 3.58 / 175.74 | 2 | 3 |
6 | 13 | 555.80 | 31 | 13.83 | 1159 | 497 | 4.08 / 176.23 | 2 | 5 |
7 | 13 | 98.00 | 6 | 14.22 | 534 | 46 | 4.13 / 176.28 | 2 | 4 |
8 | 8 | 0.40 | 190 | 14.01 | 398 | 1059 | 5.19 / 177.34 | 2 | 20 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 35 | 14.17 | 549 | 272 | 0.27 / 167.30 | 2 | 3 |
2 | 12 | 1135.52 | 4 | 13.34 | 2049 | 109 | 0.38 / 167.41 | 2 | 2 |
3 | 7 | 2011.84 | 50 | 12.39 | 3325 | 2060 | 2.44 / 169.47 | 2 | 2 |
4 | 13 | 1509.64 | 31 | 13.13 | 2577 | 1049 | 3.49 / 170.52 | 2 | 4 |
5 | 13 | 598.76 | 31 | 13.80 | 1238 | 530 | 4.02 / 171.05 | 2 | 4 |
6 | 13 | 43.08 | 6 | 14.23 | 467 | 40 | 4.06 / 171.09 | 2 | 4 |
7 | 8 | -0.20 | 190 | 14.01 | 401 | 1067 | 5.13 / 172.15 | 2 | 20 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 35 | 14.16 | 540 | 268 | 0.27 / 162.04 | 2 | 3 |
2 | 12 | 1119.04 | 4 | 13.37 | 2027 | 108 | 0.38 / 162.15 | 2 | 2 |
3 | 7 | 2001.32 | 50 | 12.44 | 3322 | 2066 | 2.44 / 164.22 | 2 | 2 |
4 | 13 | 1501.08 | 31 | 13.15 | 2571 | 1048 | 3.49 / 165.27 | 2 | 4 |
5 | 13 | 565.28 | 31 | 13.84 | 1185 | 508 | 4.00 / 165.77 | 2 | 4 |
6 | 13 | 17.32 | 31 | 14.28 | 434 | 192 | 4.19 / 165.97 | 2 | 5 |
7 | 8 | 0.16 | 190 | 13.94 | 400 | 1059 | 5.25 / 167.03 | 2 | 22 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 35 | 14.17 | 546 | 271 | 0.27 / 156.78 | 2 | 3 |
2 | 12 | 1149.56 | 4 | 13.39 | 2090 | 112 | 0.38 / 156.89 | 2 | 2 |
3 | 7 | 2001.48 | 50 | 12.49 | 3309 | 2066 | 2.45 / 158.96 | 2 | 2 |
4 | 13 | 1506.72 | 31 | 13.15 | 2581 | 1052 | 3.50 / 160.01 | 2 | 4 |
5 | 13 | 567.32 | 31 | 13.84 | 1190 | 511 | 4.01 / 160.52 | 2 | 4 |
6 | 13 | 29.96 | 31 | 14.29 | 447 | 198 | 4.21 / 160.72 | 2 | 4 |
7 | 8 | 0.32 | 190 | 13.98 | 398 | 1057 | 5.27 / 161.78 | 2 | 24 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 35 | 14.20 | 538 | 267 | 0.27 / 151.49 | 2 | 3 |
2 | 12 | 1136.40 | 4 | 13.55 | 2043 | 111 | 0.38 / 151.60 | 2 | 2 |
3 | 7 | 2003.16 | 51 | 12.54 | 3316 | 2121 | 2.50 / 153.72 | 2 | 2 |
4 | 13 | 1521.12 | 31 | 13.17 | 2606 | 1064 | 3.56 / 154.79 | 2 | 4 |
5 | 13 | 569.44 | 31 | 13.86 | 1177 | 506 | 4.07 / 155.29 | 2 | 5 |
6 | 13 | 1.28 | 31 | 14.33 | 405 | 180 | 4.25 / 155.47 | 2 | 4 |
7 | 8 | 0.08 | 190 | 13.94 | 392 | 1038 | 5.29 / 156.51 | 2 | 21 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 34 | 14.21 | 546 | 264 | 0.26 / 146.34 | 2 | 3 |
2 | 12 | 1144.24 | 4 | 13.61 | 2032 | 111 | 0.37 / 146.45 | 2 | 2 |
3 | 7 | 2002.72 | 50 | 12.59 | 3299 | 2077 | 2.45 / 148.53 | 2 | 2 |
4 | 13 | 1484.76 | 31 | 13.20 | 2562 | 1048 | 3.50 / 149.58 | 2 | 5 |
5 | 13 | 405.72 | 31 | 14.00 | 953 | 414 | 3.91 / 149.99 | 2 | 4 |
6 | 13 | 17.88 | 31 | 14.32 | 422 | 187 | 4.10 / 150.18 | 2 | 4 |
7 | 8 | 0.16 | 190 | 14.01 | 392 | 1043 | 5.14 / 151.22 | 2 | 25 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 33 | 14.25 | 539 | 253 | 0.25 / 141.09 | 2 | 3 |
2 | 3 | 1038.40 | 1 | 14.37 | 1924 | 28 | 0.28 / 141.11 | 2 | 3 |
3 | 12 | 1124.20 | 4 | 13.64 | 2006 | 109 | 0.39 / 141.22 | 2 | 2 |
4 | 7 | 2000.80 | 50 | 12.63 | 3299 | 2083 | 2.47 / 143.31 | 2 | 2 |
5 | 13 | 1498.00 | 31 | 13.22 | 2557 | 1048 | 3.52 / 144.36 | 2 | 4 |
6 | 13 | 549.12 | 31 | 13.90 | 1147 | 494 | 4.02 / 144.85 | 2 | 5 |
7 | 13 | 17.96 | 31 | 14.33 | 422 | 187 | 4.20 / 145.04 | 2 | 4 |
8 | 8 | 0.16 | 190 | 14.02 | 391 | 1042 | 5.25 / 146.08 | 2 | 21 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 34 | 14.24 | 533 | 258 | 0.26 / 135.86 | 2 | 3 |
2 | 3 | 944.88 | -1 | 14.24 | 533 | 0 | 0.00 / 135.86 | 2 | 3 |
3 | 12 | 1111.20 | 4 | 13.77 | 2032 | 112 | 0.37 / 135.97 | 2 | 2 |
4 | 7 | 2008.40 | 50 | 12.68 | 3317 | 2103 | 2.47 / 138.07 | 2 | 2 |
5 | 13 | 1474.72 | 31 | 13.25 | 2525 | 1037 | 3.51 / 139.11 | 2 | 4 |
6 | 13 | 553.56 | 31 | 13.92 | 1153 | 498 | 4.01 / 139.61 | 2 | 4 |
7 | 13 | 17.40 | 31 | 14.35 | 423 | 188 | 4.20 / 139.79 | 2 | 4 |
8 | 8 | -0.36 | 190 | 13.99 | 391 | 1039 | 5.24 / 140.83 | 2 | 23 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 34 | 14.23 | 531 | 257 | 0.26 / 130.74 | 2 | 3 |
2 | 12 | 1134.48 | 4 | 13.88 | 2029 | 113 | 0.37 / 130.86 | 2 | 2 |
3 | 7 | 2008.56 | 50 | 12.74 | 3306 | 2106 | 2.48 / 132.96 | 2 | 2 |
4 | 13 | 1324.72 | 31 | 13.37 | 2301 | 954 | 3.43 / 133.92 | 2 | 5 |
5 | 13 | 420.12 | 31 | 14.04 | 968 | 421 | 3.85 / 134.34 | 2 | 5 |
6 | 13 | 31.12 | 5 | 14.36 | 443 | 32 | 3.88 / 134.37 | 2 | 4 |
7 | 13 | 17.80 | 31 | 14.32 | 422 | 187 | 4.07 / 134.56 | 2 | 4 |
8 | 8 | 0.24 | 190 | 14.03 | 391 | 1042 | 5.11 / 135.60 | 2 | 25 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 33 | 14.26 | 543 | 256 | 0.26 / 125.57 | 2 | 3 |
2 | 3 | 1023.84 | 1 | 14.39 | 1878 | 27 | 0.28 / 125.59 | 2 | 3 |
3 | 12 | 1150.24 | 4 | 14.00 | 2029 | 114 | 0.40 / 125.71 | 2 | 2 |
4 | 7 | 2004.92 | 50 | 12.79 | 3300 | 2110 | 2.51 / 127.82 | 2 | 3 |
5 | 13 | 1682.32 | 31 | 13.17 | 2826 | 1154 | 3.66 / 128.97 | 2 | 3 |
6 | 13 | 510.72 | 31 | 13.98 | 1098 | 476 | 4.14 / 129.45 | 2 | 5 |
7 | 8 | 0.08 | 190 | 14.10 | 388 | 1039 | 5.18 / 130.49 | 2 | 17 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 33 | 14.26 | 550 | 259 | 0.26 / 120.80 | 2 | 3 |
2 | 12 | 1128.16 | 4 | 13.97 | 2038 | 114 | 0.37 / 120.92 | 2 | 2 |
3 | 7 | 2005.04 | 50 | 12.80 | 3311 | 2119 | 2.49 / 123.04 | 2 | 2 |
4 | 13 | 1335.84 | 31 | 13.39 | 2322 | 964 | 3.46 / 124.00 | 2 | 4 |
5 | 13 | 318.72 | 7 | 14.24 | 839 | 84 | 3.54 / 124.08 | 2 | 5 |
6 | 13 | 199.52 | 6 | 14.29 | 676 | 58 | 3.60 / 124.14 | 2 | 5 |
7 | 13 | 130.16 | 6 | 14.32 | 585 | 50 | 3.65 / 124.19 | 2 | 5 |
8 | 13 | 52.08 | 6 | 14.37 | 468 | 40 | 3.69 / 124.23 | 2 | 4 |
9 | 13 | 46.20 | 6 | 14.37 | 471 | 41 | 3.73 / 124.27 | 2 | 4 |
10 | 8 | 0.56 | 190 | 14.05 | 389 | 1038 | 4.77 / 125.31 | 2 | 24 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 33 | 14.28 | 550 | 259 | 0.26 / 115.73 | 2 | 3 |
2 | 12 | 1139.08 | 4 | 14.03 | 2021 | 113 | 0.37 / 115.85 | 2 | 2 |
3 | 7 | 2003.32 | 51 | 12.82 | 3304 | 2160 | 2.53 / 118.01 | 2 | 2 |
4 | 13 | 1482.04 | 31 | 13.31 | 2538 | 1047 | 3.58 / 119.05 | 2 | 5 |
5 | 13 | 376.08 | 8 | 14.21 | 937 | 107 | 3.69 / 119.16 | 2 | 5 |
6 | 13 | 217.16 | 6 | 14.31 | 704 | 60 | 3.75 / 119.22 | 2 | 5 |
7 | 13 | 131.00 | 6 | 14.33 | 589 | 51 | 3.80 / 119.27 | 2 | 5 |
8 | 13 | 85.84 | 6 | 14.35 | 524 | 45 | 3.84 / 119.32 | 2 | 4 |
9 | 13 | 17.20 | 31 | 14.35 | 426 | 190 | 4.03 / 119.51 | 2 | 4 |
10 | 8 | -0.16 | 190 | 14.01 | 390 | 1038 | 5.07 / 120.54 | 2 | 26 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 33 | 14.26 | 548 | 258 | 0.26 / 110.59 | 2 | 4 |
2 | 12 | 1129.64 | 4 | 13.99 | 2014 | 113 | 0.37 / 110.71 | 2 | 2 |
3 | 7 | 2011.00 | 51 | 12.84 | 3312 | 2169 | 2.54 / 112.87 | 2 | 2 |
4 | 13 | 1331.76 | 31 | 13.42 | 2297 | 956 | 3.50 / 113.83 | 2 | 4 |
5 | 13 | 411.76 | 31 | 14.08 | 947 | 413 | 3.91 / 114.24 | 2 | 5 |
6 | 13 | 17.96 | 31 | 14.38 | 423 | 189 | 4.10 / 114.43 | 2 | 4 |
7 | 8 | -0.12 | 190 | 14.05 | 390 | 1041 | 5.14 / 115.47 | 2 | 24 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 32 | 14.29 | 546 | 250 | 0.25 / 105.54 | 2 | 4 |
2 | 7 | 2008.08 | 51 | 12.94 | 3308 | 2183 | 2.43 / 107.72 | 2 | 2 |
3 | 13 | 1590.44 | 31 | 13.30 | 2696 | 1112 | 3.54 / 108.84 | 2 | 4 |
4 | 13 | 442.84 | 31 | 14.08 | 993 | 433 | 3.98 / 109.27 | 2 | 4 |
5 | 8 | 0.36 | 190 | 14.10 | 398 | 1066 | 5.04 / 110.34 | 2 | 21 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 31 | 14.25 | 573 | 253 | 0.25 / 100.58 | 2 | 4 |
2 | 3 | 1042.00 | 1 | 14.49 | 1969 | 29 | 0.28 / 100.61 | 2 | 2 |
3 | 7 | 2008.80 | 50 | 12.95 | 3306 | 2141 | 2.42 / 102.75 | 2 | 3 |
4 | 13 | 1582.00 | 25 | 13.40 | 2702 | 905 | 3.33 / 103.66 | 2 | 4 |
5 | 13 | 691.28 | 25 | 13.95 | 1360 | 474 | 3.80 / 104.13 | 2 | 5 |
6 | 13 | 125.00 | 6 | 14.38 | 578 | 50 | 3.85 / 104.18 | 2 | 4 |
7 | 13 | 50.84 | 6 | 14.41 | 486 | 42 | 3.89 / 104.22 | 2 | 4 |
8 | 8 | 0.28 | 190 | 14.08 | 399 | 1067 | 4.96 / 105.29 | 2 | 23 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 21 | 14.38 | 549 | 166 | 0.17 / 95.28 | 2 | 4 |
2 | 10 | 1013.40 | 5 | 14.43 | 1864 | 134 | 0.30 / 95.42 | 2 | 3 |
3 | 10 | 1045.56 | 3 | 14.33 | 1914 | 82 | 0.38 / 95.50 | 2 | 4 |
4 | 3 | 1042.84 | 1 | 14.52 | 1894 | 28 | 0.41 / 95.53 | 2 | 3 |
5 | 7 | 2007.68 | 51 | 12.97 | 3312 | 2191 | 2.60 / 97.72 | 2 | 2 |
6 | 13 | 1588.16 | 25 | 13.41 | 2686 | 900 | 3.50 / 98.62 | 2 | 4 |
7 | 13 | 698.96 | 25 | 13.96 | 1381 | 482 | 3.98 / 99.10 | 2 | 5 |
8 | 13 | 128.44 | 6 | 14.38 | 582 | 50 | 4.03 / 99.15 | 2 | 4 |
9 | 13 | 46.20 | 6 | 14.41 | 476 | 41 | 4.07 / 99.19 | 2 | 4 |
10 | 13 | 44.00 | 6 | 14.41 | 466 | 40 | 4.11 / 99.23 | 2 | 5 |
11 | 13 | 41.20 | 6 | 14.38 | 456 | 39 | 4.15 / 99.27 | 2 | 4 |
12 | 8 | 0.28 | 190 | 14.06 | 396 | 1058 | 5.21 / 100.33 | 2 | 24 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 21 | 14.37 | 563 | 170 | 0.17 / 90.44 | 2 | 4 |
2 | 7 | 2003.60 | 50 | 12.93 | 3303 | 2135 | 2.31 / 92.57 | 4 | 3 |
3 | 13 | 1401.52 | 25 | 13.50 | 2419 | 816 | 3.12 / 93.39 | 2 | 4 |
4 | 13 | 561.56 | 25 | 14.04 | 1172 | 411 | 3.53 / 93.80 | 2 | 4 |
5 | 13 | 113.48 | 6 | 14.40 | 567 | 49 | 3.58 / 93.85 | 2 | 5 |
6 | 13 | 58.84 | 6 | 14.40 | 501 | 43 | 3.63 / 93.89 | 2 | 4 |
7 | 13 | 51.20 | 6 | 14.39 | 488 | 42 | 3.67 / 93.94 | 2 | 5 |
8 | 13 | 47.08 | 6 | 14.36 | 483 | 42 | 3.71 / 93.98 | 2 | 5 |
9 | 13 | 44.28 | 6 | 14.32 | 479 | 41 | 3.75 / 94.02 | 2 | 6 |
10 | 13 | 41.32 | 6 | 14.29 | 468 | 40 | 3.79 / 94.06 | 2 | 5 |
11 | 8 | -0.20 | 190 | 14.04 | 397 | 1059 | 4.85 / 95.12 | 2 | 25 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 21 | 14.35 | 566 | 171 | 0.17 / 86.69 | 2 | 3 |
2 | 3 | 1028.52 | 1 | 14.49 | 1932 | 28 | 0.20 / 86.72 | 2 | 2 |
3 | 7 | 2012.16 | 50 | 12.94 | 3314 | 2144 | 2.34 / 88.86 | 2 | 3 |
4 | 13 | 1394.72 | 25 | 13.51 | 2418 | 817 | 3.16 / 89.68 | 2 | 4 |
5 | 13 | 738.72 | 25 | 13.93 | 1432 | 499 | 3.66 / 90.18 | 2 | 4 |
6 | 13 | 92.24 | 6 | 14.42 | 536 | 46 | 3.70 / 90.22 | 2 | 5 |
7 | 13 | 67.84 | 6 | 14.42 | 509 | 44 | 3.75 / 90.27 | 2 | 5 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 20 | 14.39 | 557 | 160 | 0.16 / 82.89 | 2 | 4 |
2 | 7 | 2006.08 | 51 | 12.95 | 3308 | 2185 | 2.35 / 85.07 | 2 | 2 |
3 | 13 | 1398.20 | 25 | 13.51 | 2423 | 818 | 3.16 / 85.89 | 2 | 5 |
4 | 13 | 727.00 | 25 | 13.94 | 1424 | 496 | 3.66 / 86.39 | 2 | 5 |
5 | 13 | 90.40 | 6 | 14.42 | 530 | 46 | 3.71 / 86.43 | 2 | 5 |
6 | 13 | 69.48 | 6 | 14.45 | 506 | 44 | 3.75 / 86.48 | 2 | 5 |
7 | 13 | 56.12 | 6 | 14.39 | 490 | 42 | 3.79 / 86.52 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 20 | 14.37 | 553 | 159 | 0.16 / 79.16 | 2 | 4 |
2 | 7 | 2001.48 | 51 | 12.94 | 3309 | 2184 | 2.34 / 81.35 | 4 | 3 |
3 | 13 | 1383.28 | 25 | 13.51 | 2406 | 813 | 3.16 / 82.16 | 2 | 4 |
4 | 13 | 704.24 | 25 | 13.96 | 1384 | 483 | 3.64 / 82.64 | 2 | 5 |
5 | 13 | 84.84 | 6 | 14.42 | 524 | 45 | 3.68 / 82.69 | 2 | 4 |
6 | 13 | 51.96 | 6 | 14.42 | 491 | 42 | 3.73 / 82.73 | 2 | 5 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 20 | 14.37 | 555 | 160 | 0.16 / 75.57 | 2 | 4 |
2 | 7 | 2012.40 | 50 | 12.95 | 3327 | 2154 | 2.31 / 77.72 | 4 | 3 |
3 | 13 | 1380.04 | 25 | 13.53 | 2380 | 805 | 3.12 / 78.52 | 2 | 4 |
4 | 13 | 520.68 | 25 | 14.11 | 1093 | 386 | 3.50 / 78.91 | 2 | 4 |
5 | 13 | 96.88 | 6 | 14.43 | 541 | 47 | 3.55 / 78.96 | 2 | 4 |
6 | 13 | 70.28 | 6 | 14.43 | 521 | 45 | 3.60 / 79.00 | 2 | 5 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 20 | 14.39 | 562 | 162 | 0.16 / 71.83 | 2 | 4 |
2 | 3 | 1023.20 | 1 | 14.50 | 1943 | 28 | 0.19 / 71.85 | 2 | 2 |
3 | 7 | 2010.52 | 50 | 12.98 | 3311 | 2149 | 2.34 / 74.00 | 2 | 3 |
4 | 13 | 1390.60 | 25 | 13.52 | 2415 | 816 | 3.16 / 74.82 | 2 | 4 |
5 | 13 | 729.96 | 25 | 13.96 | 1415 | 494 | 3.65 / 75.31 | 2 | 4 |
6 | 13 | 143.40 | 6 | 14.41 | 605 | 52 | 3.70 / 75.37 | 2 | 4 |
7 | 13 | 40.28 | 6 | 14.47 | 462 | 40 | 3.74 / 75.41 | 2 | 5 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 19 | 14.41 | 551 | 151 | 0.15 / 68.09 | 2 | 4 |
2 | 7 | 2001.96 | 50 | 12.97 | 3310 | 2147 | 2.30 / 70.24 | 2 | 3 |
3 | 13 | 1362.24 | 25 | 13.53 | 2384 | 806 | 3.10 / 71.04 | 2 | 4 |
4 | 13 | 707.32 | 25 | 13.97 | 1388 | 485 | 3.59 / 71.53 | 2 | 5 |
5 | 13 | 123.76 | 6 | 14.43 | 580 | 50 | 3.64 / 71.58 | 2 | 4 |
6 | 13 | 61.68 | 6 | 14.45 | 500 | 43 | 3.68 / 71.62 | 2 | 5 |
7 | 13 | 51.20 | 6 | 14.43 | 481 | 42 | 3.72 / 71.66 | 2 | 5 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 19 | 14.40 | 565 | 155 | 0.15 / 64.42 | 2 | 4 |
2 | 7 | 2003.16 | 50 | 12.99 | 3302 | 2145 | 2.30 / 66.56 | 2 | 3 |
3 | 13 | 1593.44 | 25 | 13.41 | 2715 | 910 | 3.21 / 67.47 | 2 | 4 |
4 | 13 | 498.60 | 25 | 14.11 | 1081 | 381 | 3.59 / 67.85 | 2 | 5 |
5 | 13 | 93.20 | 6 | 14.46 | 534 | 46 | 3.64 / 67.90 | 2 | 5 |
6 | 13 | 43.52 | 6 | 14.46 | 474 | 41 | 3.68 / 67.94 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 18 | 14.42 | 551 | 143 | 0.14 / 60.81 | 2 | 4 |
2 | 3 | 1031.56 | 1 | 14.53 | 1957 | 28 | 0.17 / 60.84 | 2 | 2 |
3 | 7 | 2002.96 | 50 | 12.99 | 3309 | 2149 | 2.32 / 62.99 | 2 | 3 |
4 | 13 | 1366.16 | 25 | 13.54 | 2379 | 805 | 3.13 / 63.80 | 2 | 4 |
5 | 13 | 494.20 | 25 | 14.12 | 1070 | 378 | 3.50 / 64.17 | 2 | 5 |
6 | 13 | 90.28 | 6 | 14.46 | 532 | 46 | 3.55 / 64.22 | 2 | 4 |
7 | 13 | 46.64 | 6 | 14.47 | 488 | 42 | 3.59 / 64.26 | 2 | 4 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 17 | 14.45 | 558 | 137 | 0.14 / 57.17 | 2 | 4 |
2 | 10 | 1018.32 | 3 | 14.58 | 1871 | 82 | 0.22 / 57.25 | 2 | 4 |
3 | 3 | 967.64 | -1 | 14.58 | 1871 | 0 | 0.08 / 57.25 | 2 | 4 |
4 | 7 | 2001.16 | 50 | 13.00 | 3312 | 2153 | 2.37 / 59.40 | 2 | 3 |
5 | 13 | 1365.00 | 25 | 13.55 | 2355 | 798 | 3.17 / 60.20 | 2 | 4 |
6 | 13 | 497.12 | 25 | 14.12 | 1078 | 381 | 3.55 / 60.58 | 2 | 5 |
7 | 13 | 88.32 | 6 | 14.47 | 533 | 46 | 3.60 / 60.63 | 2 | 4 |
8 | 13 | 67.08 | 6 | 14.46 | 508 | 44 | 3.64 / 60.67 | 2 | 5 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 27 | 14.30 | 563 | 217 | 0.22 / 53.72 | 2 | 4 |
2 | 3 | 696.84 | -6 | 14.30 | 563 | 0 | 0.00 / 53.72 | 2 | 4 |
3 | 3 | 890.92 | -2 | 14.30 | 563 | 0 | 0.00 / 53.72 | 2 | 4 |
4 | 7 | 2010.72 | 50 | 13.00 | 3331 | 2165 | 2.38 / 55.88 | 4 | 2 |
5 | 13 | 1164.12 | 25 | 13.65 | 2059 | 703 | 3.09 / 56.59 | 2 | 4 |
6 | 13 | 532.56 | 25 | 14.09 | 1141 | 402 | 3.49 / 56.99 | 2 | 6 |
7 | 13 | 53.20 | 6 | 14.48 | 493 | 43 | 3.53 / 57.03 | 2 | 4 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 28 | 14.27 | 568 | 227 | 0.23 / 49.93 | 2 | 5 |
2 | 3 | 970.84 | -1 | 14.27 | 568 | 0 | 0.00 / 49.93 | 2 | 5 |
3 | 7 | 2001.08 | 51 | 13.01 | 3314 | 2199 | 2.43 / 52.13 | 2 | 3 |
4 | 13 | 1352.48 | 25 | 13.53 | 2384 | 806 | 3.23 / 52.93 | 2 | 4 |
5 | 13 | 690.32 | 25 | 13.97 | 1374 | 480 | 3.71 / 53.41 | 2 | 6 |
6 | 13 | 75.92 | 6 | 14.49 | 526 | 46 | 3.76 / 53.46 | 2 | 5 |
7 | 13 | 42.00 | 6 | 14.50 | 480 | 42 | 3.80 / 53.50 | 2 | 5 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 27 | 14.33 | 547 | 212 | 0.21 / 44.83 | 2 | 4 |
2 | 3 | 1035.76 | 1 | 14.53 | 1954 | 28 | 0.24 / 44.86 | 2 | 2 |
3 | 7 | 2003.60 | 50 | 13.01 | 3305 | 2150 | 2.39 / 47.01 | 2 | 2 |
4 | 13 | 1570.76 | 25 | 13.42 | 2687 | 901 | 3.29 / 47.91 | 2 | 4 |
5 | 13 | 637.52 | 25 | 14.01 | 1286 | 450 | 3.74 / 48.36 | 2 | 5 |
6 | 13 | 111.72 | 6 | 14.49 | 557 | 48 | 3.79 / 48.41 | 2 | 4 |
7 | 13 | 58.72 | 6 | 14.50 | 496 | 43 | 3.83 / 48.45 | 2 | 4 |
8 | 13 | 41.32 | 6 | 14.48 | 470 | 41 | 3.87 / 48.49 | 2 | 4 |
9 | 13 | 18.32 | 25 | 14.40 | 432 | 156 | 4.03 / 48.65 | 2 | 6 |
10 | 8 | 0.12 | 190 | 14.03 | 396 | 1056 | 5.09 / 49.70 | 2 | 25 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 27 | 14.35 | 539 | 209 | 0.21 / 40.15 | 2 | 4 |
2 | 7 | 2009.08 | 50 | 13.01 | 3312 | 2154 | 2.36 / 42.30 | 2 | 2 |
3 | 13 | 1338.24 | 25 | 13.54 | 2322 | 786 | 3.15 / 43.09 | 2 | 4 |
4 | 13 | 473.64 | 25 | 14.13 | 1046 | 369 | 3.52 / 43.46 | 2 | 5 |
5 | 13 | 83.72 | 6 | 14.52 | 523 | 46 | 3.56 / 43.51 | 2 | 4 |
6 | 13 | 63.80 | 6 | 14.50 | 498 | 43 | 3.61 / 43.55 | 2 | 4 |
7 | 8 | 0.36 | 190 | 14.10 | 398 | 1066 | 4.67 / 44.62 | 2 | 21 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 28 | 14.32 | 558 | 224 | 0.22 / 35.39 | 2 | 4 |
2 | 3 | 968.20 | -1 | 14.32 | 558 | 0 | 0.00 / 35.39 | 2 | 4 |
3 | 7 | 2007.44 | 50 | 13.00 | 3316 | 2155 | 2.38 / 37.55 | 2 | 3 |
4 | 13 | 1351.40 | 25 | 13.52 | 2348 | 794 | 3.17 / 38.34 | 2 | 4 |
5 | 13 | 664.40 | 25 | 13.98 | 1310 | 458 | 3.63 / 38.80 | 2 | 5 |
6 | 13 | 70.72 | 6 | 14.53 | 504 | 44 | 3.67 / 38.84 | 2 | 4 |
7 | 13 | 40.48 | 6 | 14.53 | 464 | 40 | 3.71 / 38.88 | 2 | 4 |
8 | 8 | 0.20 | 190 | 14.09 | 396 | 1060 | 4.78 / 39.94 | 2 | 22 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 27 | 14.38 | 544 | 211 | 0.21 / 30.67 | 2 | 3 |
2 | 3 | 1025.20 | 1 | 14.50 | 1914 | 28 | 0.24 / 30.70 | 2 | 2 |
3 | 7 | 2003.68 | 50 | 12.98 | 3313 | 2150 | 2.39 / 32.85 | 2 | 2 |
4 | 13 | 1355.92 | 25 | 13.51 | 2339 | 790 | 3.18 / 33.64 | 2 | 4 |
5 | 13 | 465.72 | 25 | 14.11 | 1034 | 365 | 3.54 / 34.00 | 2 | 5 |
6 | 13 | 80.32 | 6 | 14.52 | 517 | 45 | 3.59 / 34.05 | 2 | 4 |
7 | 13 | 42.08 | 6 | 14.53 | 475 | 41 | 3.63 / 34.09 | 2 | 4 |
8 | 8 | 0.36 | 190 | 14.07 | 403 | 1077 | 4.71 / 35.17 | 2 | 21 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 27 | 14.36 | 521 | 202 | 0.20 / 25.89 | 2 | 3 |
2 | 3 | 1021.56 | 1 | 14.51 | 1889 | 27 | 0.23 / 25.92 | 2 | 2 |
3 | 7 | 2003.04 | 50 | 12.96 | 3303 | 2140 | 2.37 / 28.06 | 2 | 2 |
4 | 13 | 1359.28 | 25 | 13.47 | 2368 | 797 | 3.17 / 28.86 | 2 | 4 |
5 | 13 | 474.44 | 25 | 14.10 | 1050 | 370 | 3.54 / 29.23 | 2 | 5 |
6 | 13 | 80.56 | 6 | 14.53 | 515 | 45 | 3.58 / 29.27 | 2 | 5 |
7 | 13 | 61.60 | 6 | 14.50 | 495 | 43 | 3.63 / 29.32 | 2 | 5 |
8 | 13 | 53.16 | 6 | 14.46 | 484 | 42 | 3.67 / 29.36 | 2 | 4 |
9 | 13 | 46.72 | 6 | 14.43 | 472 | 41 | 3.71 / 29.40 | 2 | 5 |
10 | 8 | -0.12 | 190 | 14.04 | 397 | 1059 | 4.77 / 30.46 | 2 | 22 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 25 | 14.38 | 522 | 188 | 0.19 / 21.17 | 2 | 3 |
2 | 3 | 1052.16 | 1 | 14.53 | 1922 | 28 | 0.22 / 21.20 | 2 | 3 |
3 | 7 | 2002.76 | 50 | 12.93 | 3291 | 2128 | 2.34 / 23.32 | 2 | 2 |
4 | 13 | 1358.00 | 25 | 13.45 | 2346 | 789 | 3.13 / 24.11 | 2 | 4 |
5 | 13 | 450.24 | 25 | 14.12 | 995 | 351 | 3.48 / 24.46 | 2 | 5 |
6 | 13 | 48.56 | 6 | 14.55 | 477 | 42 | 3.52 / 24.50 | 2 | 4 |
7 | 13 | 6.00 | 25 | 14.46 | 414 | 150 | 3.67 / 24.65 | 2 | 5 |
8 | 8 | 0.12 | 190 | 14.00 | 390 | 1037 | 4.71 / 25.69 | 2 | 23 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 24 | 14.35 | 528 | 182 | 0.18 / 16.50 | 2 | 3 |
2 | 3 | 1028.88 | 1 | 14.43 | 1936 | 28 | 0.21 / 16.53 | 2 | 2 |
3 | 7 | 2002.32 | 50 | 12.87 | 3291 | 2118 | 2.33 / 18.65 | 2 | 2 |
4 | 13 | 1355.16 | 25 | 13.40 | 2353 | 788 | 3.12 / 19.44 | 2 | 4 |
5 | 13 | 462.24 | 25 | 14.06 | 1033 | 363 | 3.48 / 19.80 | 2 | 5 |
6 | 13 | 17.84 | 25 | 14.47 | 418 | 151 | 3.63 / 19.95 | 2 | 4 |
7 | 8 | 0.20 | 190 | 14.01 | 387 | 1030 | 4.66 / 20.98 | 2 | 23 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 25 | 14.33 | 519 | 186 | 0.19 / 12.75 | 2 | 3 |
2 | 7 | 1508.68 | 50 | 13.18 | 2543 | 1676 | 1.86 / 14.43 | 2 | 3 |
3 | 13 | 1091.04 | 25 | 13.56 | 1939 | 657 | 2.52 / 15.09 | 2 | 4 |
4 | 13 | 218.24 | 6 | 14.36 | 698 | 60 | 2.58 / 15.15 | 2 | 4 |
5 | 13 | 138.52 | 6 | 14.42 | 587 | 51 | 2.63 / 15.20 | 2 | 5 |
6 | 13 | 97.32 | 6 | 14.41 | 534 | 46 | 2.68 / 15.24 | 2 | 5 |
7 | 13 | 47.44 | 6 | 14.44 | 473 | 41 | 2.72 / 15.29 | 2 | 4 |
8 | 8 | -0.04 | 190 | 14.02 | 388 | 1034 | 3.75 / 16.32 | 2 | 21 |
Average= | 3.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 24 | 14.36 | 500 | 172 | 0.17 / 9.10 | 2 | 3 |
2 | 7 | 1506.40 | 50 | 13.08 | 2547 | 1666 | 1.84 / 10.76 | 2 | 3 |
3 | 13 | 1073.40 | 25 | 13.52 | 1895 | 641 | 2.48 / 11.40 | 2 | 4 |
4 | 13 | 220.28 | 6 | 14.29 | 705 | 60 | 2.54 / 11.46 | 2 | 5 |
5 | 13 | 139.04 | 6 | 14.36 | 582 | 50 | 2.59 / 11.51 | 2 | 5 |
6 | 13 | 91.52 | 6 | 14.37 | 518 | 45 | 2.63 / 11.56 | 2 | 5 |
7 | 8 | 0.00 | 190 | 14.02 | 379 | 1010 | 3.64 / 12.57 | 2 | 18 |
Average= | 3.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 24 | 14.31 | 500 | 172 | 0.17 / 4.94 | 2 | 3 |
2 | 7 | 1513.56 | 75 | 12.74 | 2546 | 2433 | 2.60 / 7.37 | 2 | 3 |
3 | 13 | 519.80 | 20 | 13.94 | 1080 | 301 | 2.91 / 7.67 | 2 | 5 |
4 | 13 | 88.04 | 6 | 14.33 | 502 | 43 | 2.95 / 7.71 | 2 | 4 |
5 | 13 | 44.84 | 6 | 14.36 | 442 | 38 | 2.99 / 7.75 | 2 | 4 |
6 | 8 | 0.12 | 240 | 13.98 | 350 | 1174 | 4.16 / 8.93 | 2 | 29 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 27 | 14.35 | 492 | 191 | 0.19 / 1.87 | 2 | 3 |
2 | 3 | 823.80 | -3 | 14.35 | 492 | 0 | 0.00 / 1.87 | 2 | 3 |
3 | 3 | 930.72 | -1 | 14.35 | 492 | 0 | 0.00 / 1.87 | 2 | 3 |
4 | 7 | 952.04 | 75 | 13.04 | 1673 | 1636 | 1.83 / 3.51 | 3 | 4 |
5 | 13 | 2.80 | 20 | 14.32 | 369 | 106 | 1.93 / 3.61 | 2 | 4 |
6 | 8 | 0.04 | 240 | 13.92 | 345 | 1153 | 3.09 / 4.76 | 2 | 28 |
Average= | 2.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 26 | 14.39 | 468 | 175 | 0.18 / 0.18 | 2 | 2 |
2 | 7 | 106.40 | 74 | 14.11 | 464 | 484 | 0.66 / 0.66 | 2 | 3 |
3 | 8 | 0.16 | 240 | 14.16 | 300 | 1020 | 1.68 / 1.68 | 2 | 46 |
Average= | 1.68 (KJ/cycle) |