SIO Argo Site:
Pump Diagnostics Page   



Serial= 3307 WMO= 5907123

Return

←PreviousNext→

Cycle 17 GMT 9/ 4/2025 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 33 15.15 458 229 0.23 / 63.81 2 2
2 7 2008.48 38 14.92 2799 1587 1.82 / 65.39 2 3
3 13 1451.20 18 14.97 2172 585 2.40 / 65.98 2 6
4 13 958.00 18 15.03 1551 420 2.82 / 66.40 2 7
5 13 355.16 18 15.17 786 215 3.04 / 66.61 2 8
6 13 44.80 18 15.24 374 103 3.14 / 66.71 2 8
7 8 0.12 165 15.19 302 757 3.89 / 67.47 2 20
Average= 3.75
(KJ/cycle)

Cycle 16 GMT 30/ 3/2025 17:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 33 15.16 454 227 0.23 / 59.95 2 2
2 7 2010.36 38 14.91 2799 1586 1.81 / 61.53 2 3
3 13 1410.44 18 14.97 2119 571 2.38 / 62.11 2 5
4 13 966.40 18 15.03 1566 424 2.81 / 62.53 2 8
5 13 285.52 18 15.20 691 189 3.00 / 62.72 2 7
6 13 40.76 18 15.24 367 101 3.10 / 62.82 2 8
7 8 0.08 165 15.20 302 757 3.85 / 63.58 2 23
Average= 3.74
(KJ/cycle)

Cycle 15 GMT 20/ 3/2025 22:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 33 15.17 458 229 0.23 / 56.12 2 2
2 7 2011.60 38 14.92 2813 1595 1.82 / 57.72 2 4
3 13 1406.52 18 14.97 2115 570 2.39 / 58.29 2 5
4 13 848.24 18 15.07 1405 381 2.78 / 58.67 2 6
5 13 317.96 18 15.18 738 202 2.98 / 58.87 2 7
6 13 29.20 18 15.24 351 96 3.07 / 58.97 2 7
7 8 0.12 165 15.18 301 754 3.83 / 59.72 2 20
Average= 3.73
(KJ/cycle)

Cycle 14 GMT 11/ 3/2025 3:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 33 15.17 451 226 0.23 / 52.27 2 2
2 7 2006.16 38 14.92 2805 1590 1.82 / 53.86 2 3
3 13 1405.04 18 14.98 2095 565 2.38 / 54.42 2 4
4 13 922.56 18 15.05 1505 408 2.79 / 54.83 2 7
5 13 325.16 18 15.19 749 205 2.99 / 55.04 2 8
6 13 30.04 18 15.25 354 97 3.09 / 55.13 2 8
7 8 -0.24 165 15.21 303 760 3.85 / 55.89 2 20
Average= 3.73
(KJ/cycle)

Cycle 13 GMT 1/ 3/2025 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 33 15.17 449 225 0.22 / 48.37 2 2
2 7 2003.64 39 14.95 2806 1636 1.86 / 50.00 2 4
3 13 1446.00 18 14.99 2161 583 2.44 / 50.59 2 7
4 13 918.72 18 15.07 1505 408 2.85 / 50.99 2 7
5 13 329.40 18 15.20 748 205 3.06 / 51.20 2 8
6 13 33.04 18 15.24 355 97 3.15 / 51.30 2 9
7 8 -0.04 165 15.20 298 747 3.90 / 52.04 2 18
Average= 3.72
(KJ/cycle)

Cycle 12 GMT 19/ 2/2025 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 33 15.18 446 223 0.22 / 44.52 2 2
2 7 2008.72 39 14.92 2797 1628 1.85 / 46.14 2 4
3 13 1412.84 18 14.98 2109 569 2.42 / 46.71 2 4
4 13 935.68 18 15.04 1515 410 2.83 / 47.12 2 6
5 13 293.16 18 15.19 701 192 3.02 / 47.31 2 8
6 13 19.64 18 15.25 329 90 3.11 / 47.40 2 10
7 8 0.00 165 15.20 294 737 3.85 / 48.14 2 19
Average= 3.70
(KJ/cycle)

Cycle 11 GMT 9/ 2/2025 19:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 33 15.19 454 228 0.23 / 40.67 2 2
2 7 2005.28 38 14.96 2780 1580 1.81 / 42.25 2 3
3 13 1384.88 18 15.01 2075 561 2.37 / 42.81 2 6
4 13 956.32 18 15.07 1543 419 2.79 / 43.23 2 6
5 13 356.88 18 15.20 780 213 3.00 / 43.44 2 8
6 13 42.48 18 15.26 366 101 3.10 / 43.54 2 9
7 8 0.04 165 15.23 299 751 3.85 / 44.29 2 20
Average= 3.69
(KJ/cycle)

Cycle 10 GMT 31/ 1/2025 0:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 33 15.19 459 230 0.23 / 36.18 2 2
2 7 2008.76 74 14.83 2792 3064 3.29 / 39.25 2 5
3 13 688.04 18 15.13 1200 327 3.62 / 39.57 2 9
4 13 83.92 18 15.27 419 115 3.74 / 39.69 2 8
5 8 0.08 165 15.23 299 751 4.49 / 40.44 2 18
Average= 3.68
(KJ/cycle)

Cycle 9 GMT 21/ 1/2025 3:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 32 15.19 455 221 0.22 / 31.62 2 2
2 10 1008.72 2 15.25 1656 51 0.27 / 31.67 2 3
3 7 2008.44 75 14.81 2797 3107 3.38 / 34.77 2 6
4 13 628.32 18 15.14 1125 307 3.69 / 35.08 2 8
5 13 117.80 18 15.25 464 127 3.81 / 35.21 2 8
6 8 0.12 165 15.23 297 746 4.56 / 35.95 2 20
Average= 3.60
(KJ/cycle)

Cycle 8 GMT 11/ 1/2025 6:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 31 15.22 454 214 0.21 / 27.10 2 2
2 3 1031.64 1 15.31 1669 26 0.24 / 27.13 2 3
3 7 2005.68 74 14.81 2795 3063 3.30 / 30.19 2 5
4 13 683.20 18 15.13 1180 321 3.62 / 30.51 2 8
5 13 115.76 18 15.25 464 127 3.75 / 30.64 2 8
6 8 -0.04 165 15.23 301 756 4.51 / 31.39 2 19
Average= 3.49
(KJ/cycle)

Cycle 7 GMT 1/ 1/2025 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 32 15.22 451 220 0.22 / 23.35 2 2
2 7 1515.28 74 15.01 2227 2474 2.69 / 25.82 2 6
3 13 346.88 18 15.25 767 211 2.90 / 26.03 2 7
4 13 35.24 18 15.30 357 98 3.00 / 26.13 2 8
5 8 0.20 165 15.25 301 757 3.76 / 26.89 2 19
Average= 3.36
(KJ/cycle)

Cycle 6 GMT 31/12/2024 10: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 32 15.21 456 222 0.22 / 19.58 2 2
2 7 1512.40 74 15.01 2233 2480 2.70 / 22.06 2 5
3 13 346.72 18 15.25 765 210 2.91 / 22.27 2 7
4 13 35.76 18 15.30 356 98 3.01 / 22.37 2 8
5 8 0.08 165 15.25 301 757 3.77 / 23.13 2 20
Average= 3.30
(KJ/cycle)

Cycle 5 GMT 30/12/2024 10:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 32 15.21 459 223 0.22 / 15.80 2 2
2 7 1519.32 74 15.01 2241 2489 2.71 / 18.28 2 7
3 13 350.84 18 15.24 773 212 2.92 / 18.50 2 7
4 13 40.20 18 15.28 365 100 3.03 / 18.60 2 8
5 8 0.08 165 15.24 303 762 3.79 / 19.36 2 17
Average= 3.23
(KJ/cycle)

Cycle 4 GMT 29/12/2024 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 32 15.20 457 222 0.22 / 12.11 2 2
2 7 1527.84 74 14.99 2250 2496 2.72 / 14.60 2 8
3 13 347.16 18 15.23 766 210 2.93 / 14.81 2 7
4 8 0.12 165 15.25 302 760 3.69 / 15.57 2 19
Average= 3.11
(KJ/cycle)

Cycle 3 GMT 28/12/2024 11:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 30 15.22 456 208 0.21 / 8.28 2 2
2 10 1008.12 2 15.24 1652 50 0.26 / 8.33 2 3
3 7 1525.00 74 15.00 2245 2492 2.75 / 10.83 2 6
4 13 341.32 18 15.24 756 207 2.96 / 11.03 2 7
5 13 18.96 18 15.29 330 91 3.05 / 11.12 2 8
6 8 -0.08 165 15.25 302 760 3.81 / 11.88 2 20
Average= 2.97
(KJ/cycle)

Cycle 2 GMT 27/12/2024 11:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 33 15.25 458 230 0.23 / 4.54 2 2
2 3 921.76 -1 15.63 0 0 0.00 / 4.54 2 2
3 3 948.24 -1 15.64 0 0 0.00 / 4.54 2 2
4 7 1507.00 74 15.01 2225 2471 2.70 / 7.02 2 7
5 13 325.24 18 15.25 738 203 2.90 / 7.22 2 7
6 13 37.32 18 15.29 361 99 3.00 / 7.32 2 9
7 8 0.00 165 15.25 301 757 3.76 / 8.08 2 20
Average= 2.69
(KJ/cycle)

Cycle 1 GMT 26/12/2024 12:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 28 15.43 408 176 0.18 / 1.69 2 2
2 10 1043.44 2 15.32 1675 51 0.23 / 1.74 2 3
3 3 1022.28 1 15.35 1651 25 0.25 / 1.76 2 3
4 7 1007.04 74 15.17 1586 1780 2.03 / 3.54 2 10
5 8 -0.16 165 15.31 305 770 2.80 / 4.31 2 18
Average= 2.16
(KJ/cycle)

Cycle 0 GMT 26/12/2024 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.84 28 15.58 306 133 0.13 / 0.13 2 3
2 7 70.68 74 15.54 363 417 0.55 / 0.55 2 3
3 8 0.48 240 15.49 258 959 1.51 / 1.51 2 16
Average= 1.51
(KJ/cycle)