SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 31 | 15.20 | 398 | 188 | 0.19 / 63.17 | 2 | 3 |
2 | 7 | 2004.88 | 38 | 14.92 | 2720 | 1542 | 1.73 / 64.71 | 2 | 4 |
3 | 13 | 1397.20 | 18 | 14.97 | 2067 | 557 | 2.29 / 65.27 | 2 | 5 |
4 | 13 | 862.72 | 18 | 15.06 | 1383 | 375 | 2.66 / 65.64 | 2 | 6 |
5 | 13 | 361.04 | 18 | 15.18 | 743 | 203 | 2.86 / 65.85 | 2 | 6 |
6 | 13 | 18.64 | 18 | 15.26 | 276 | 76 | 2.94 / 65.92 | 2 | 5 |
7 | 8 | -0.12 | 165 | 15.23 | 249 | 626 | 3.57 / 66.55 | 2 | 16 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 31 | 15.20 | 393 | 185 | 0.19 / 59.60 | 2 | 3 |
2 | 7 | 2004.52 | 38 | 14.93 | 2710 | 1537 | 1.72 / 61.14 | 2 | 7 |
3 | 13 | 1373.64 | 18 | 14.98 | 2040 | 550 | 2.27 / 61.69 | 2 | 7 |
4 | 13 | 934.84 | 18 | 15.04 | 1487 | 403 | 2.68 / 62.09 | 2 | 7 |
5 | 13 | 327.92 | 18 | 15.19 | 698 | 191 | 2.87 / 62.28 | 2 | 6 |
6 | 13 | 30.00 | 18 | 15.26 | 290 | 80 | 2.95 / 62.36 | 2 | 5 |
7 | 8 | 0.00 | 165 | 15.23 | 246 | 618 | 3.56 / 62.98 | 2 | 15 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 31 | 15.21 | 397 | 187 | 0.19 / 56.04 | 2 | 3 |
2 | 7 | 2011.48 | 38 | 14.93 | 2700 | 1532 | 1.72 / 57.58 | 2 | 4 |
3 | 13 | 1409.68 | 18 | 14.97 | 2077 | 560 | 2.28 / 58.13 | 2 | 7 |
4 | 13 | 909.48 | 18 | 15.06 | 1442 | 391 | 2.67 / 58.53 | 2 | 7 |
5 | 13 | 353.40 | 18 | 15.18 | 731 | 200 | 2.87 / 58.73 | 2 | 6 |
6 | 13 | 21.88 | 18 | 15.25 | 280 | 77 | 2.95 / 58.80 | 2 | 5 |
7 | 8 | 0.28 | 165 | 15.23 | 245 | 616 | 3.56 / 59.42 | 2 | 14 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 31 | 15.21 | 398 | 188 | 0.19 / 52.50 | 2 | 3 |
2 | 7 | 2005.04 | 38 | 14.94 | 2694 | 1529 | 1.72 / 54.03 | 2 | 7 |
3 | 13 | 1409.20 | 18 | 14.99 | 2073 | 559 | 2.28 / 54.59 | 2 | 9 |
4 | 13 | 908.04 | 18 | 15.06 | 1439 | 390 | 2.67 / 54.98 | 2 | 6 |
5 | 13 | 310.56 | 18 | 15.20 | 678 | 186 | 2.85 / 55.16 | 2 | 6 |
6 | 13 | 23.16 | 18 | 15.26 | 283 | 78 | 2.93 / 55.24 | 2 | 5 |
7 | 8 | 0.24 | 165 | 15.24 | 245 | 616 | 3.55 / 55.86 | 2 | 16 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 31 | 15.21 | 384 | 181 | 0.18 / 48.95 | 2 | 3 |
2 | 7 | 2008.96 | 38 | 14.93 | 2710 | 1537 | 1.72 / 50.49 | 2 | 3 |
3 | 13 | 1415.48 | 18 | 14.98 | 2083 | 562 | 2.28 / 51.05 | 2 | 10 |
4 | 13 | 839.08 | 18 | 15.09 | 1352 | 367 | 2.65 / 51.42 | 2 | 6 |
5 | 13 | 342.84 | 18 | 15.20 | 716 | 196 | 2.84 / 51.61 | 2 | 6 |
6 | 13 | 17.36 | 18 | 15.27 | 275 | 76 | 2.92 / 51.69 | 2 | 5 |
7 | 8 | 0.16 | 165 | 15.24 | 248 | 624 | 3.54 / 52.31 | 2 | 16 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 31 | 15.21 | 400 | 189 | 0.19 / 45.41 | 2 | 3 |
2 | 7 | 2002.96 | 39 | 14.95 | 2652 | 1546 | 1.73 / 46.95 | 2 | 5 |
3 | 13 | 1395.12 | 18 | 15.00 | 2053 | 554 | 2.29 / 47.51 | 2 | 5 |
4 | 13 | 855.36 | 18 | 15.07 | 1378 | 374 | 2.66 / 47.88 | 2 | 6 |
5 | 13 | 318.36 | 18 | 15.21 | 686 | 188 | 2.85 / 48.07 | 2 | 5 |
6 | 13 | 24.48 | 18 | 15.28 | 286 | 79 | 2.93 / 48.15 | 2 | 5 |
7 | 8 | -0.12 | 165 | 15.24 | 247 | 621 | 3.55 / 48.77 | 2 | 16 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 31 | 15.20 | 394 | 186 | 0.19 / 41.89 | 2 | 3 |
2 | 3 | 1016.64 | 1 | 15.29 | 1551 | 24 | 0.21 / 41.91 | 2 | 4 |
3 | 7 | 2003.68 | 38 | 14.93 | 2676 | 1518 | 1.73 / 43.43 | 2 | 7 |
4 | 13 | 1354.92 | 18 | 14.99 | 2003 | 540 | 2.27 / 43.97 | 2 | 6 |
5 | 13 | 866.88 | 18 | 15.08 | 1381 | 375 | 2.64 / 44.34 | 2 | 6 |
6 | 13 | 279.60 | 18 | 15.21 | 636 | 174 | 2.82 / 44.52 | 2 | 6 |
7 | 13 | 16.72 | 18 | 15.27 | 274 | 75 | 2.89 / 44.59 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.24 | 248 | 624 | 3.52 / 45.22 | 2 | 16 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 31 | 15.23 | 387 | 183 | 0.18 / 38.36 | 2 | 3 |
2 | 7 | 2005.52 | 38 | 14.93 | 2681 | 1521 | 1.70 / 39.88 | 2 | 6 |
3 | 13 | 1398.40 | 18 | 14.99 | 2056 | 555 | 2.26 / 40.44 | 2 | 7 |
4 | 13 | 860.16 | 18 | 15.08 | 1384 | 376 | 2.63 / 40.81 | 2 | 7 |
5 | 13 | 310.92 | 18 | 15.20 | 677 | 185 | 2.82 / 41.00 | 2 | 5 |
6 | 13 | 18.72 | 18 | 15.27 | 278 | 76 | 2.90 / 41.08 | 2 | 5 |
7 | 8 | 0.16 | 165 | 15.23 | 249 | 626 | 3.52 / 41.70 | 2 | 17 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 31 | 15.23 | 385 | 182 | 0.18 / 34.21 | 2 | 3 |
2 | 7 | 2004.20 | 74 | 14.82 | 2707 | 2969 | 3.15 / 37.17 | 2 | 9 |
3 | 13 | 542.44 | 18 | 15.17 | 968 | 264 | 3.41 / 37.44 | 2 | 7 |
4 | 13 | 95.32 | 18 | 15.27 | 386 | 106 | 3.52 / 37.55 | 2 | 6 |
5 | 8 | 0.12 | 165 | 15.26 | 252 | 635 | 4.16 / 38.18 | 2 | 14 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 30 | 15.23 | 407 | 186 | 0.19 / 30.04 | 2 | 3 |
2 | 3 | 1025.00 | 1 | 15.26 | 1671 | 25 | 0.21 / 30.07 | 2 | 3 |
3 | 7 | 2003.28 | 74 | 14.81 | 2704 | 2963 | 3.17 / 33.03 | 2 | 9 |
4 | 13 | 605.28 | 18 | 15.14 | 1046 | 285 | 3.46 / 33.32 | 2 | 6 |
5 | 13 | 51.44 | 18 | 15.28 | 320 | 88 | 3.55 / 33.41 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.26 | 246 | 619 | 4.17 / 34.02 | 2 | 15 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 31 | 15.22 | 399 | 188 | 0.19 / 25.89 | 2 | 3 |
2 | 7 | 2004.60 | 74 | 14.82 | 2724 | 2987 | 3.18 / 28.87 | 2 | 6 |
3 | 13 | 553.88 | 18 | 15.17 | 993 | 271 | 3.45 / 29.15 | 2 | 5 |
4 | 13 | 30.80 | 18 | 15.29 | 296 | 81 | 3.53 / 29.23 | 2 | 5 |
5 | 8 | 0.00 | 165 | 15.26 | 250 | 629 | 4.16 / 29.86 | 2 | 17 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 30 | 15.22 | 396 | 181 | 0.18 / 22.00 | 2 | 3 |
2 | 7 | 1806.72 | 74 | 14.87 | 2517 | 2770 | 2.95 / 24.77 | 2 | 7 |
3 | 13 | 396.64 | 18 | 15.20 | 794 | 217 | 3.17 / 24.99 | 2 | 6 |
4 | 13 | 31.28 | 18 | 15.28 | 296 | 81 | 3.25 / 25.07 | 2 | 4 |
5 | 8 | -0.08 | 165 | 15.25 | 250 | 629 | 3.88 / 25.70 | 2 | 15 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 29 | 15.22 | 395 | 174 | 0.17 / 18.10 | 2 | 3 |
2 | 3 | 1032.68 | 1 | 15.24 | 1669 | 25 | 0.20 / 18.12 | 2 | 3 |
3 | 7 | 1817.64 | 74 | 14.87 | 2527 | 2781 | 2.98 / 20.91 | 2 | 7 |
4 | 13 | 396.36 | 18 | 15.20 | 785 | 215 | 3.20 / 21.12 | 2 | 6 |
5 | 13 | 27.40 | 18 | 15.28 | 289 | 79 | 3.27 / 21.20 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.25 | 247 | 622 | 3.90 / 21.82 | 2 | 15 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 29 | 15.25 | 381 | 168 | 0.17 / 14.23 | 2 | 2 |
2 | 7 | 1807.56 | 74 | 14.87 | 2519 | 2772 | 2.94 / 17.00 | 2 | 8 |
3 | 13 | 391.84 | 18 | 15.21 | 782 | 214 | 3.15 / 17.22 | 2 | 7 |
4 | 13 | 22.72 | 18 | 15.29 | 283 | 78 | 3.23 / 17.29 | 2 | 4 |
5 | 8 | 0.12 | 165 | 15.26 | 251 | 632 | 3.86 / 17.92 | 2 | 16 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 28 | 15.26 | 382 | 163 | 0.16 / 10.77 | 2 | 3 |
2 | 10 | 1012.12 | 2 | 15.25 | 1602 | 49 | 0.21 / 10.81 | 2 | 3 |
3 | 7 | 1507.80 | 75 | 14.98 | 2175 | 2444 | 2.66 / 13.26 | 2 | 8 |
4 | 13 | 284.40 | 18 | 15.26 | 646 | 177 | 2.83 / 13.44 | 2 | 5 |
5 | 8 | 0.08 | 165 | 15.28 | 248 | 625 | 3.46 / 14.06 | 2 | 13 |
Average= | 2.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 33 | 15.24 | 386 | 194 | 0.19 / 7.39 | 2 | 3 |
2 | 3 | 874.24 | -2 | 15.59 | 0 | 0 | 0.00 / 7.39 | 2 | 3 |
3 | 3 | 915.60 | -2 | 15.62 | 0 | 0 | 0.00 / 7.39 | 2 | 3 |
4 | 7 | 1509.80 | 74 | 14.98 | 2176 | 2412 | 2.61 / 9.81 | 2 | 6 |
5 | 13 | 299.12 | 18 | 15.24 | 656 | 180 | 2.79 / 9.99 | 2 | 7 |
6 | 8 | 0.04 | 165 | 15.28 | 244 | 615 | 3.40 / 10.60 | 2 | 14 |
Average= | 2.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 33 | 15.28 | 395 | 199 | 0.20 / 3.97 | 2 | 2 |
2 | 7 | 1524.76 | 74 | 14.98 | 2191 | 2429 | 2.63 / 6.40 | 2 | 6 |
3 | 13 | 299.48 | 18 | 15.25 | 658 | 181 | 2.81 / 6.58 | 2 | 6 |
4 | 8 | 0.16 | 165 | 15.28 | 246 | 620 | 3.43 / 7.20 | 2 | 14 |
Average= | 2.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 28 | 15.45 | 351 | 152 | 0.15 / 1.41 | 3 | 3 |
2 | 7 | 1008.00 | 74 | 15.16 | 1542 | 1730 | 1.88 / 3.14 | 2 | 7 |
3 | 8 | -0.24 | 165 | 15.33 | 248 | 627 | 2.51 / 3.77 | 2 | 15 |
Average= | 1.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 69.60 | 28 | 15.60 | 293 | 128 | 0.13 / 0.13 | 3 | 3 |
2 | 7 | 85.76 | 74 | 15.57 | 322 | 371 | 0.50 / 0.50 | 3 | 3 |
3 | 8 | 0.32 | 240 | 15.53 | 205 | 764 | 1.26 / 1.26 | 3 | 17 |
Average= | 1.26 (KJ/cycle) |