SIO Argo Site:
Pump Diagnostics Page   



Serial= 3286 WMO= 5907034

Return

←PreviousNext→

Cycle 17 GMT 10/ 3/2025 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 23 15.28 459 161 0.16 / 62.17 2 2
2 7 2008.24 38 14.84 2928 1651 1.81 / 63.82 2 3
3 13 1344.16 18 14.98 2123 572 2.38 / 64.39 2 4
4 13 792.92 18 15.11 1411 384 2.77 / 64.78 2 4
5 13 133.76 18 15.31 504 139 2.91 / 64.92 2 6
6 8 0.08 165 15.31 301 760 3.67 / 65.68 2 22
Average= 3.65
(KJ/cycle)

Cycle 16 GMT 28/ 2/2025 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 24 15.28 459 168 0.17 / 58.46 2 2
2 7 2006.64 39 14.86 2943 1706 1.87 / 60.16 2 4
3 13 1340.44 18 15.02 2118 573 2.45 / 60.74 2 4
4 13 767.28 18 15.15 1368 373 2.82 / 61.11 2 5
5 13 97.36 18 15.35 453 125 2.94 / 61.23 2 6
6 8 -0.16 165 15.33 306 774 3.72 / 62.01 2 23
Average= 3.65
(KJ/cycle)

Cycle 15 GMT 19/ 2/2025 0:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 24 15.28 463 170 0.17 / 54.79 2 2
2 7 2008.08 38 14.86 2924 1651 1.82 / 56.44 2 3
3 13 1301.44 18 15.02 2070 560 2.38 / 57.00 2 3
4 13 812.92 18 15.11 1441 392 2.77 / 57.39 2 5
5 13 107.56 18 15.35 465 128 2.90 / 57.52 2 6
6 8 0.08 165 15.32 305 771 3.67 / 58.29 2 20
Average= 3.64
(KJ/cycle)

Cycle 14 GMT 9/ 2/2025 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 24 15.28 461 169 0.17 / 51.09 2 2
2 7 2010.12 38 14.85 2941 1660 1.83 / 52.75 2 3
3 13 1390.88 18 14.98 2199 593 2.42 / 53.34 2 3
4 13 769.52 18 15.14 1383 377 2.80 / 53.72 2 5
5 13 105.48 18 15.34 464 128 2.93 / 53.85 2 5
6 8 0.36 165 15.33 304 769 3.70 / 54.62 2 20
Average= 3.64
(KJ/cycle)

Cycle 13 GMT 30/ 1/2025 10:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 24 15.27 457 167 0.17 / 47.38 2 2
2 7 2010.92 38 14.86 2931 1655 1.82 / 49.03 2 4
3 13 1403.44 18 15.01 2173 587 2.41 / 49.62 2 3
4 13 817.64 18 15.13 1441 392 2.80 / 50.01 2 5
5 13 162.04 18 15.33 538 148 2.95 / 50.16 2 6
6 8 0.44 165 15.33 301 761 3.71 / 50.92 2 19
Average= 3.64
(KJ/cycle)

Cycle 12 GMT 20/ 1/2025 14:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 24 15.30 463 170 0.17 / 43.47 2 2
2 7 2005.48 38 14.88 2918 1650 1.82 / 45.12 2 4
3 13 1356.08 18 15.02 2117 572 2.39 / 45.69 2 4
4 13 791.60 18 15.15 1402 382 2.77 / 46.08 2 4
5 13 145.28 18 15.34 515 142 2.92 / 46.22 2 5
6 13 16.08 18 15.37 328 91 3.01 / 46.31 2 5
7 8 0.32 165 15.33 301 761 3.77 / 47.07 2 21
8 14 0.32 30 15.31 301 138 3.91 / 47.21 4 22
Average= 3.63
(KJ/cycle)

Cycle 11 GMT 10/ 1/2025 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 24 15.28 461 169 0.17 / 39.79 2 2
2 7 2006.80 38 14.89 2939 1663 1.83 / 41.46 2 3
3 13 1339.04 18 15.03 2103 569 2.40 / 42.02 2 4
4 13 800.36 18 15.15 1418 387 2.79 / 42.41 2 5
5 13 103.64 18 15.36 458 127 2.91 / 42.54 2 6
6 8 0.12 165 15.35 302 765 3.68 / 43.30 2 19
Average= 3.61
(KJ/cycle)

Cycle 10 GMT 1/ 1/2025 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 24 15.28 468 172 0.17 / 36.13 2 2
2 7 2008.28 38 14.88 2908 1644 1.82 / 37.77 2 3
3 13 1343.72 18 15.01 2121 573 2.39 / 38.34 2 4
4 13 773.52 18 15.14 1385 377 2.77 / 38.72 2 5
5 13 124.56 18 15.34 489 135 2.90 / 38.86 2 6
6 8 0.28 165 15.33 303 766 3.67 / 39.62 2 23
Average= 3.60
(KJ/cycle)

Cycle 9 GMT 22/12/2024 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 24 15.30 467 171 0.17 / 32.40 2 2
2 7 2009.92 39 14.85 2951 1709 1.88 / 34.10 2 3
3 13 1375.32 18 15.00 2163 584 2.46 / 34.69 2 3
4 13 743.92 18 15.16 1331 363 2.83 / 35.05 2 5
5 13 142.96 18 15.34 513 142 2.97 / 35.19 2 6
6 8 0.04 165 15.34 301 762 3.73 / 35.96 2 18
Average= 3.60
(KJ/cycle)

Cycle 8 GMT 12/12/2024 9:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 31 15.28 460 218 0.22 / 27.98 2 3
2 3 753.48 -5 15.66 1 0 0.00 / 27.98 2 3
3 3 968.12 -1 15.69 1 0 0.00 / 27.98 2 3
4 7 2008.44 74 14.76 2930 3200 3.42 / 31.18 2 6
5 13 522.16 18 15.24 1037 284 3.70 / 31.46 2 6
6 8 0.04 165 15.35 300 760 4.46 / 32.22 2 17
Average= 3.58
(KJ/cycle)

Cycle 7 GMT 2/12/2024 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 23 15.28 469 165 0.16 / 23.79 2 2
2 10 1003.56 2 15.22 1725 53 0.22 / 23.85 2 3
3 7 1804.76 74 14.82 2672 2930 3.15 / 26.78 2 5
4 13 360.08 18 15.27 813 223 3.37 / 27.00 2 5
5 8 0.24 165 15.33 301 761 4.13 / 27.76 2 20
Average= 3.47
(KJ/cycle)

Cycle 6 GMT 1/12/2024 11:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 22 15.29 457 154 0.15 / 19.66 2 2
2 3 1036.56 1 15.27 1729 26 0.18 / 19.68 2 3
3 7 1815.84 74 14.83 2678 2939 3.12 / 22.62 2 4
4 13 408.16 18 15.26 879 241 3.36 / 22.86 2 5
5 8 0.16 165 15.34 302 764 4.12 / 23.63 2 18
Average= 3.38
(KJ/cycle)

Cycle 5 GMT 30/11/2024 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 23 15.31 458 161 0.16 / 15.58 2 3
2 3 963.28 -1 15.67 0 0 0.00 / 15.58 2 3
3 7 1813.16 74 14.82 2683 2942 3.10 / 18.52 2 4
4 13 358.56 18 15.27 809 222 3.33 / 18.74 2 5
5 8 -0.04 165 15.34 301 762 4.09 / 19.50 2 21
Average= 3.25
(KJ/cycle)

Cycle 4 GMT 29/11/2024 10:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 22 15.29 459 154 0.15 / 11.88 2 2
2 10 1010.32 2 15.24 1747 53 0.21 / 11.93 2 3
3 7 1523.56 74 14.95 2333 2581 2.79 / 14.52 2 4
4 13 139.20 18 15.37 505 140 2.93 / 14.66 2 5
5 8 0.08 165 15.37 300 761 3.69 / 15.42 2 21
Average= 3.08
(KJ/cycle)

Cycle 3 GMT 28/11/2024 11: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 8 15.32 442 54 0.05 / 7.73 2 2
2 10 1089.48 6 15.15 1838 167 0.22 / 7.90 2 3
3 10 1160.08 4 15.12 1935 117 0.34 / 8.02 2 2
4 10 1191.68 2 15.16 1977 60 0.40 / 8.08 2 3
5 3 1178.04 5 15.17 1964 149 0.55 / 8.22 2 3
6 3 1028.88 1 15.30 1753 27 0.57 / 8.25 2 2
7 7 1525.48 74 14.93 2328 2572 3.15 / 10.82 2 5
8 13 179.20 18 15.36 553 153 3.30 / 10.98 2 5
9 8 -0.04 165 15.37 296 751 4.05 / 11.73 2 18
Average= 2.93
(KJ/cycle)

Cycle 2 GMT 27/11/2024 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 33 15.37 447 227 0.23 / 4.36 2 3
2 3 575.88 -8 15.70 0 0 0.00 / 4.36 2 3
3 3 617.44 -7 15.70 1 0 0.00 / 4.36 2 3
4 7 1462.96 74 15.00 2220 2464 2.69 / 6.82 2 3
5 13 107.56 18 15.38 446 123 2.81 / 6.95 2 5
6 8 0.16 165 15.36 289 732 3.55 / 7.68 2 21
Average= 2.56
(KJ/cycle)

Cycle 1 GMT 26/11/2024 11:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 28 15.50 415 180 0.18 / 1.76 2 3
2 3 792.04 -4 15.70 0 0 0.00 / 1.76 2 3
3 3 825.40 -3 15.72 1 0 0.00 / 1.76 2 3
4 7 853.92 74 15.24 1451 1636 1.82 / 3.40 2 7
5 8 -0.08 165 15.44 288 734 2.55 / 4.13 2 20
Average= 2.07
(KJ/cycle)

Cycle 0 GMT 26/11/2024 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 94.24 28 15.63 400 175 0.18 / 0.18 2 3
2 7 109.52 75 15.60 412 482 0.66 / 0.66 2 3
3 8 0.36 240 15.58 247 924 1.58 / 1.58 2 38
Average= 1.58
(KJ/cycle)