SIO Argo Site:
Pump Diagnostics Page   



Serial= 3247 WMO= 5907025

Return

←PreviousNext→

Cycle 19 GMT 5/ 1/2025 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 43 15.28 472 310 0.31 / 55.65 2 9
2 7 2012.68 74 14.82 2882 3161 3.47 / 58.81 2 16
3 13 566.84 18 15.19 1063 291 3.76 / 59.10 2 18
4 8 0.08 165 15.27 341 859 4.62 / 59.96 2 23
Average= 3.00
(KJ/cycle)

Cycle 18 GMT 26/12/2024 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 43 15.27 472 310 0.31 / 52.16 2 13
2 7 1395.88 74 15.06 2106 2347 2.66 / 54.51 2 15
3 8 -1.44 165 15.33 329 832 3.49 / 55.34 2 25
Average= 2.91
(KJ/cycle)

Cycle 17 GMT 16/12/2024 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 43 15.34 477 315 0.31 / 48.59 2 7
2 7 1423.48 75 15.06 2148 2426 2.74 / 51.02 2 14
3 8 0.24 165 15.34 328 830 3.57 / 51.85 2 28
Average= 2.88
(KJ/cycle)

Cycle 16 GMT 6/12/2024 8:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 42 15.30 474 305 0.30 / 45.85 2 11
2 3 521.52 1 15.41 1033 16 0.32 / 45.87 2 11
3 7 809.44 74 15.30 1391 1575 1.90 / 47.45 2 15
4 8 -0.12 165 15.41 327 831 2.73 / 48.28 2 27
Average= 2.84
(KJ/cycle)

Cycle 15 GMT 5/12/2024 5:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 43 15.27 477 313 0.31 / 42.72 2 14
2 10 515.40 2 15.33 1021 31 0.34 / 42.75 2 12
3 3 449.52 -1 15.54 0 0 0.03 / 42.75 2 12
4 7 1109.36 74 15.18 1761 1978 2.32 / 44.73 2 17
5 8 0.12 165 15.38 325 825 3.15 / 45.55 2 26
Average= 2.85
(KJ/cycle)

Cycle 14 GMT 4/12/2024 2:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 43 15.30 486 320 0.32 / 39.21 2 11
2 7 1370.96 74 15.06 2104 2345 2.66 / 41.55 2 15
3 8 0.28 165 15.34 335 848 3.51 / 42.40 2 22
Average= 2.83
(KJ/cycle)

Cycle 13 GMT 2/12/2024 23:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 42 15.29 494 317 0.32 / 35.99 2 15
2 3 524.68 1 15.39 1019 16 0.33 / 36.01 2 11
3 7 1149.96 74 15.16 1824 2046 2.38 / 38.06 2 17
4 8 0.16 165 15.37 329 834 3.21 / 38.89 2 16
Average= 2.78
(KJ/cycle)

Cycle 12 GMT 1/12/2024 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 42 15.34 441 284 0.28 / 32.88 2 14
2 7 1099.40 74 15.19 1749 1966 2.25 / 34.84 2 17
3 8 -0.84 165 15.37 329 834 3.08 / 35.68 2 31
Average= 2.74
(KJ/cycle)

Cycle 11 GMT 30/11/2024 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 42 15.35 446 288 0.29 / 30.12 2 14
2 3 527.08 1 15.42 1033 16 0.30 / 30.14 2 11
3 7 919.92 75 15.27 1490 1706 2.01 / 31.84 2 16
4 8 0.08 165 15.41 294 748 2.76 / 32.59 2 21
Average= 2.72
(KJ/cycle)

Cycle 10 GMT 29/11/2024 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 41 15.34 432 272 0.27 / 27.60 2 14
2 10 514.24 2 15.37 1010 31 0.30 / 27.64 2 11
3 3 467.08 -1 15.56 0 0 0.03 / 27.64 2 11
4 7 767.00 74 15.32 1289 1461 1.76 / 29.10 2 16
5 8 -0.04 165 15.43 290 738 2.50 / 29.83 2 28
Average= 2.71
(KJ/cycle)

Cycle 9 GMT 28/11/2024 12:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 37 15.33 435 247 0.25 / 24.91 2 7
2 10 513.08 4 15.32 1009 62 0.31 / 24.97 2 11
3 3 557.48 2 15.39 1074 33 0.34 / 25.01 2 13
4 7 856.12 74 15.29 1406 1591 1.93 / 26.60 2 15
5 8 -0.12 165 15.41 289 735 2.67 / 27.33 2 25
Average= 2.73
(KJ/cycle)

Cycle 8 GMT 27/11/2024 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 37 15.33 459 260 0.26 / 22.08 2 15
2 3 731.40 1 15.35 1307 20 0.28 / 22.10 2 15
3 7 1026.16 74 15.21 1624 1828 2.11 / 23.92 2 15
4 8 -0.64 165 15.39 292 741 2.85 / 24.67 2 19
Average= 2.74
(KJ/cycle)

Cycle 7 GMT 26/11/2024 13:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 35 15.31 434 233 0.23 / 19.19 2 14
2 10 731.44 3 15.30 1304 60 0.29 / 19.25 2 13
3 7 1026.88 74 15.22 1623 1828 2.12 / 21.08 2 16
4 8 0.68 165 15.39 290 736 2.86 / 21.82 2 19
Average= 2.73
(KJ/cycle)

Cycle 6 GMT 25/11/2024 13:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 34 15.31 444 231 0.23 / 16.28 2 7
2 3 838.00 1 15.37 1440 22 0.25 / 16.31 2 13
3 7 1088.92 74 15.19 1705 1917 2.17 / 18.22 2 14
4 8 0.20 165 15.37 290 735 2.91 / 18.96 2 23
Average= 2.71
(KJ/cycle)

Cycle 5 GMT 24/11/2024 11:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 30 15.32 446 205 0.20 / 13.17 2 10
2 10 802.40 4 15.26 1393 85 0.29 / 13.25 2 14
3 10 831.96 2 15.26 1442 44 0.33 / 13.30 2 15
4 7 1161.24 74 15.16 1799 2018 2.35 / 15.32 2 16
5 8 0.16 165 15.36 291 738 3.09 / 16.05 2 23
Average= 2.68
(KJ/cycle)

Cycle 4 GMT 23/11/2024 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 15.32 434 199 0.20 / 10.24 2 12
2 7 1133.68 74 15.18 1768 1986 2.19 / 12.22 2 15
3 8 -0.96 165 15.37 292 741 2.93 / 12.96 2 28
Average= 2.59
(KJ/cycle)

Cycle 3 GMT 22/11/2024 10:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 15.29 452 194 0.19 / 7.36 2 11
2 10 1006.44 2 15.24 1676 51 0.24 / 7.41 2 12
3 7 1065.84 74 15.19 1678 1886 2.13 / 9.30 2 19
4 8 0.12 165 15.38 291 738 2.87 / 10.04 3 23
Average= 2.51
(KJ/cycle)

Cycle 2 GMT 21/11/2024 11:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 33 15.26 437 220 0.22 / 4.43 2 13
2 3 866.52 -3 15.58 0 0 0.00 / 4.43 2 13
3 3 950.84 -1 15.60 0 0 0.00 / 4.43 2 13
4 7 1150.04 74 15.14 1783 1998 2.22 / 6.43 2 20
5 8 0.04 165 15.35 292 740 2.96 / 7.17 2 22
Average= 2.39
(KJ/cycle)

Cycle 1 GMT 20/11/2024 11:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 28 15.48 405 176 0.18 / 1.66 2 3
2 10 1004.00 2 15.32 1681 52 0.23 / 1.71 2 11
3 7 990.68 74 15.17 1580 1774 2.00 / 3.48 2 15
4 8 -0.16 165 15.34 288 729 2.73 / 4.21 2 21
Average= 2.11
(KJ/cycle)

Cycle 0 GMT 20/11/2024 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 72.76 28 15.61 351 153 0.15 / 0.15 2 4
2 7 87.72 74 15.60 365 421 0.57 / 0.57 3 4
3 8 0.40 240 15.55 243 907 1.48 / 1.48 2 20
Average= 1.48