SIO Argo Site:
Pump Diagnostics Page   



Serial= 3255 WMO= 5906961

Return

←PreviousNext→

Cycle 13 GMT 21/10/2024 1:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 31 15.22 424 200 0.20 / 47.13 2 2
2 7 2004.56 38 14.98 2809 1599 1.80 / 48.73 2 4
3 13 1195.64 18 15.10 1864 507 2.31 / 49.23 2 10
4 13 822.88 18 15.15 1416 386 2.69 / 49.62 2 12
5 13 432.72 18 15.23 891 244 2.94 / 49.86 2 10
6 13 71.32 18 15.31 404 111 3.05 / 49.98 2 6
7 8 0.04 165 15.26 297 748 3.80 / 50.72 2 23
Average= 3.62
(KJ/cycle)

Cycle 12 GMT 11/10/2024 6: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 31 15.22 428 202 0.20 / 43.23 2 2
2 7 2004.88 38 14.99 2814 1603 1.80 / 44.83 2 6
3 13 1340.84 18 15.09 2048 556 2.36 / 45.39 2 9
4 13 826.24 18 15.16 1403 383 2.74 / 45.77 2 12
5 13 538.72 18 15.21 1048 287 3.03 / 46.06 2 12
6 13 90.60 18 15.30 435 120 3.15 / 46.18 2 9
7 8 0.04 165 15.28 298 751 3.90 / 46.93 2 19
Average= 3.61
(KJ/cycle)

Cycle 11 GMT 1/10/2024 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 31 15.21 432 204 0.20 / 39.24 2 2
2 7 2002.28 38 14.99 2818 1605 1.81 / 40.84 2 5
3 13 1374.28 18 15.05 2093 567 2.38 / 41.41 2 8
4 13 882.60 18 15.14 1479 403 2.78 / 41.81 2 12
5 13 495.96 18 15.22 978 268 3.05 / 42.08 2 11
6 13 92.16 18 15.28 422 116 3.16 / 42.20 2 7
7 13 20.32 18 15.30 332 91 3.25 / 42.29 2 9
8 8 -0.08 165 15.26 294 740 3.99 / 43.03 2 16
Average= 3.59
(KJ/cycle)

Cycle 10 GMT 21/ 9/2024 15:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 31 15.24 415 196 0.20 / 35.42 2 2
2 7 2010.36 38 14.97 2799 1592 1.79 / 37.01 2 5
3 13 1301.72 18 15.08 1991 540 2.33 / 37.56 2 9
4 13 866.76 18 15.13 1450 395 2.72 / 37.95 2 12
5 13 435.88 18 15.23 893 245 2.97 / 38.19 2 10
6 13 70.88 18 15.30 398 110 3.08 / 38.30 2 9
7 8 0.00 165 15.26 289 728 3.81 / 39.03 2 19
Average= 3.55
(KJ/cycle)

Cycle 9 GMT 11/ 9/2024 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 31 15.24 410 194 0.19 / 31.62 2 2
2 7 2004.12 38 15.01 2786 1589 1.78 / 33.21 2 5
3 13 1358.48 18 15.08 2035 552 2.34 / 33.76 2 8
4 13 875.56 18 15.16 1452 396 2.73 / 34.16 2 12
5 13 455.92 18 15.24 910 250 2.98 / 34.41 2 10
6 13 75.04 18 15.32 389 107 3.09 / 34.51 2 7
7 8 0.08 165 15.29 283 714 3.80 / 35.23 2 16
Average= 3.52
(KJ/cycle)

Cycle 8 GMT 2/ 9/2024 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 31 15.24 421 199 0.20 / 27.78 2 2
2 7 2003.32 38 15.00 2808 1601 1.80 / 29.38 2 5
3 13 1392.44 18 15.08 2092 568 2.37 / 29.95 2 8
4 13 915.60 18 15.16 1516 414 2.78 / 30.36 2 12
5 13 435.00 18 15.25 882 242 3.02 / 30.60 2 10
6 13 92.84 18 15.32 414 114 3.14 / 30.72 2 8
7 8 0.08 165 15.29 280 706 3.84 / 31.42 2 14
Average= 3.49
(KJ/cycle)

Cycle 7 GMT 23/ 8/2024 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 15.24 426 195 0.19 / 23.94 2 2
2 10 1002.32 2 15.32 1626 50 0.24 / 23.99 2 3
3 3 966.44 -1 15.62 0 0 0.05 / 23.99 2 3
4 3 1017.76 1 15.37 1657 25 0.27 / 24.02 2 3
5 7 2002.80 39 15.01 2771 1622 1.89 / 25.64 2 7
6 13 1318.36 18 15.10 1975 537 2.43 / 26.18 2 9
7 13 833.16 18 15.18 1367 374 2.80 / 26.55 2 11
8 13 386.04 18 15.26 798 219 3.02 / 26.77 2 9
9 13 56.24 18 15.31 365 101 3.12 / 26.87 2 8
10 8 0.04 165 15.29 281 709 3.83 / 27.58 2 19
Average= 3.45
(KJ/cycle)

Cycle 6 GMT 13/ 8/2024 9:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 15.23 419 191 0.19 / 20.15 2 2
2 3 1028.64 1 15.31 1651 25 0.22 / 20.18 2 3
3 7 2007.32 38 15.00 2800 1596 1.81 / 21.77 2 5
4 13 1293.68 18 15.10 1961 533 2.35 / 22.31 2 9
5 13 848.12 18 15.17 1422 388 2.73 / 22.70 2 12
6 13 417.00 18 15.27 847 233 2.97 / 22.93 2 10
7 13 59.92 18 15.32 370 102 3.07 / 23.03 2 8
8 8 0.12 165 15.29 285 719 3.79 / 23.75 2 18
Average= 3.39
(KJ/cycle)

Cycle 5 GMT 3/ 8/2024 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 30 15.25 407 186 0.19 / 15.71 2 2
2 7 2003.44 74 14.88 2780 3061 3.25 / 18.77 2 9
3 13 530.16 18 15.24 1007 276 3.52 / 19.04 2 9
4 13 126.84 18 15.31 454 125 3.65 / 19.17 2 8
5 13 30.00 18 15.31 329 91 3.74 / 19.26 2 9
6 8 0.00 165 15.28 279 703 4.44 / 19.96 2 19
Average= 3.33
(KJ/cycle)

Cycle 4 GMT 24/ 7/2024 16:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 29 15.25 415 184 0.18 / 12.03 2 2
2 7 1508.76 74 15.07 2193 2446 2.63 / 14.47 2 9
3 13 448.16 18 15.30 895 246 2.88 / 14.72 2 9
4 13 80.68 18 15.34 390 108 2.98 / 14.83 2 8
5 8 0.08 165 15.31 274 692 3.68 / 15.52 2 17
Average= 3.10
(KJ/cycle)

Cycle 3 GMT 23/ 7/2024 17:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 29 15.28 415 184 0.18 / 8.23 2 2
2 7 1524.72 74 15.06 2217 2471 2.65 / 10.70 2 8
3 13 473.08 18 15.28 919 253 2.91 / 10.95 2 11
4 13 87.56 18 15.34 404 112 3.02 / 11.06 2 7
5 13 19.04 18 15.34 313 86 3.11 / 11.15 2 7
6 8 0.04 165 15.29 275 694 3.80 / 11.84 2 18
Average= 2.96
(KJ/cycle)

Cycle 2 GMT 22/ 7/2024 17:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 32 15.30 406 199 0.20 / 4.51 2 2
2 3 899.40 -2 15.70 0 0 0.00 / 4.51 2 2
3 3 970.16 -1 15.70 0 0 0.00 / 4.51 2 2
4 7 1524.92 74 15.08 2215 2472 2.67 / 6.98 2 6
5 13 458.36 18 15.30 908 250 2.92 / 7.23 2 10
6 13 82.16 18 15.35 397 110 3.03 / 7.34 2 7
7 8 0.20 165 15.32 277 700 3.73 / 8.04 2 16
Average= 2.68
(KJ/cycle)

Cycle 1 GMT 21/ 7/2024 18: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 27 15.44 378 158 0.16 / 1.69 2 2
2 3 1038.36 1 15.39 1707 26 0.18 / 1.72 2 3
3 7 1000.00 74 15.24 1580 1782 1.97 / 3.50 2 13
4 13 20.52 18 15.42 318 88 2.05 / 3.59 2 11
5 8 -0.08 165 15.36 286 725 2.78 / 4.31 2 17
Average= 2.16
(KJ/cycle)

Cycle 0 GMT 21/ 7/2024 7:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 149.00 27 15.62 419 177 0.18 / 0.18 2 3
2 7 165.92 74 15.59 431 497 0.67 / 0.67 2 3
3 8 0.08 240 15.53 231 861 1.53 / 1.53 2 19
Average= 1.53
(KJ/cycle)