SIO Argo Site:
Pump Diagnostics Page   



Serial= 3251 WMO= 5906957

Return

←PreviousNext→

Cycle 11 GMT 26/ 9/2024 22:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 33 15.24 398 200 0.20 / 40.67 2 2
2 7 2002.68 38 14.93 2827 1604 1.80 / 42.27 2 8
3 13 1406.56 18 15.01 2119 573 2.38 / 42.85 2 6
4 13 898.00 18 15.10 1489 405 2.78 / 43.25 2 10
5 13 503.56 18 15.20 979 268 3.05 / 43.52 2 7
6 13 42.04 18 15.32 342 94 3.14 / 43.61 2 4
7 13 25.44 18 15.31 320 88 3.23 / 43.70 2 5
8 8 0.08 165 15.28 277 698 3.93 / 44.40 2 9
Average= 3.70
(KJ/cycle)

Cycle 10 GMT 17/ 9/2024 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 33 15.24 408 205 0.21 / 36.87 2 2
2 7 2011.68 38 14.93 2841 1612 1.82 / 38.48 2 4
3 13 1354.32 18 15.02 2055 556 2.37 / 39.04 2 10
4 13 928.68 18 15.09 1523 414 2.79 / 39.45 2 7
5 13 420.52 18 15.22 861 236 3.02 / 39.69 2 4
6 13 36.40 18 15.31 333 92 3.11 / 39.78 2 7
7 8 0.04 165 15.28 274 691 3.80 / 40.47 2 19
Average= 3.68
(KJ/cycle)

Cycle 9 GMT 7/ 9/2024 8: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 33 15.25 408 205 0.21 / 33.00 2 2
2 7 2011.68 38 14.92 2832 1606 1.81 / 34.61 2 4
3 13 1371.32 18 15.01 2080 562 2.37 / 35.17 2 10
4 13 956.24 18 15.08 1568 426 2.80 / 35.60 2 8
5 13 480.20 18 15.20 944 258 3.06 / 35.86 2 6
6 13 60.72 18 15.30 371 102 3.16 / 35.96 2 4
7 8 0.04 165 15.28 281 708 3.87 / 36.67 2 6
Average= 3.67
(KJ/cycle)

Cycle 8 GMT 28/ 8/2024 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 33 15.26 425 214 0.21 / 29.10 2 2
2 3 1018.20 1 15.30 1681 26 0.24 / 29.12 2 4
3 7 2003.96 39 14.93 2824 1644 1.88 / 30.77 2 5
4 13 1358.52 18 15.05 2062 559 2.44 / 31.33 2 9
5 13 959.04 18 15.09 1563 425 2.87 / 31.75 2 7
6 13 461.20 18 15.22 921 252 3.12 / 32.00 2 7
7 13 41.04 18 15.32 345 95 3.21 / 32.10 2 4
8 8 0.20 165 15.29 278 701 3.92 / 32.80 2 9
Average= 3.64
(KJ/cycle)

Cycle 7 GMT 18/ 8/2024 17:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 32 15.25 414 202 0.20 / 25.18 2 2
2 3 1018.84 1 15.31 1693 26 0.23 / 25.20 2 3
3 7 2005.04 38 14.95 2828 1607 1.83 / 26.81 2 10
4 13 1403.40 18 15.04 2126 576 2.41 / 27.38 2 6
5 13 905.52 18 15.13 1504 410 2.82 / 27.79 2 7
6 13 558.60 18 15.21 1053 288 3.11 / 28.08 2 8
7 13 37.08 18 15.34 340 94 3.20 / 28.18 2 4
8 8 0.00 165 15.30 280 707 3.91 / 28.88 2 15
Average= 3.61
(KJ/cycle)

Cycle 6 GMT 8/ 8/2024 22:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 31 15.26 431 204 0.20 / 20.59 2 2
2 3 1048.80 1 15.31 1746 27 0.23 / 20.62 2 5
3 7 2005.32 74 14.81 2811 3081 3.31 / 23.70 2 7
4 13 710.04 18 15.15 1251 341 3.65 / 24.04 2 7
5 13 131.80 18 15.29 471 130 3.78 / 24.17 2 4
6 13 28.60 18 15.32 329 91 3.87 / 24.26 2 6
7 8 -0.04 165 15.28 283 713 4.59 / 24.97 2 13
Average= 3.57
(KJ/cycle)

Cycle 5 GMT 30/ 7/2024 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 30 15.27 436 200 0.20 / 16.15 2 2
2 3 1049.52 1 15.31 1742 27 0.23 / 16.17 2 4
3 7 2006.84 74 14.83 2815 3089 3.32 / 19.26 2 7
4 13 581.20 18 15.19 1083 296 3.61 / 19.56 2 8
5 13 77.56 18 15.33 401 111 3.72 / 19.67 2 5
6 8 0.16 165 15.31 285 720 4.44 / 20.39 2 5
Average= 3.40
(KJ/cycle)

Cycle 4 GMT 20/ 7/2024 3:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 31 15.27 429 203 0.20 / 12.41 2 2
2 7 1508.12 74 15.02 2215 2462 2.67 / 14.87 2 8
3 13 450.36 18 15.27 909 250 2.91 / 15.12 2 7
4 13 30.20 18 15.36 338 93 3.01 / 15.21 2 4
5 8 0.12 165 15.32 290 733 3.74 / 15.95 2 12
Average= 3.19
(KJ/cycle)

Cycle 3 GMT 19/ 7/2024 4:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 31 15.27 433 205 0.20 / 8.71 2 2
2 7 1513.56 74 15.00 2223 2468 2.67 / 11.18 2 8
3 13 358.72 18 15.28 783 215 2.89 / 11.39 2 7
4 13 28.92 18 15.37 329 91 2.98 / 11.48 2 10
5 8 0.04 165 15.32 285 720 3.70 / 12.20 2 17
Average= 3.05
(KJ/cycle)

Cycle 2 GMT 18/ 7/2024 4:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 32 15.31 432 212 0.21 / 5.00 2 2
2 3 965.28 -1 15.68 0 0 0.00 / 5.00 2 2
3 7 1508.56 74 15.02 2215 2462 2.67 / 7.46 2 8
4 13 367.28 18 15.28 795 219 2.89 / 7.68 2 6
5 13 48.28 18 15.35 359 99 2.99 / 7.78 2 6
6 8 0.04 165 15.32 286 723 3.71 / 8.50 2 12
Average= 2.83
(KJ/cycle)

Cycle 1 GMT 17/ 7/2024 5: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 27 15.45 387 161 0.16 / 1.76 2 2
2 10 1035.04 4 15.33 1680 103 0.26 / 1.86 2 2
3 10 1071.84 2 15.33 1726 53 0.32 / 1.92 2 3
4 3 1118.12 3 15.30 1837 84 0.40 / 2.00 2 3
5 3 1205.72 6 15.26 1937 177 0.58 / 2.18 2 4
6 7 1045.80 75 15.16 1642 1867 2.45 / 4.04 2 11
7 8 0.04 165 15.37 294 746 3.19 / 4.79 2 7
Average= 2.40
(KJ/cycle)

Cycle 0 GMT 16/ 7/2024 19:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.56 27 15.62 418 176 0.18 / 0.18 2 5
2 7 141.88 74 15.58 438 505 0.68 / 0.68 2 7
3 8 0.20 240 15.54 246 917 1.60 / 1.60 2 7
Average= 1.60
(KJ/cycle)