SIO Argo Site:
Pump Diagnostics Page   



Serial= 3239 WMO= 5906944

Return

←PreviousNext→

Cycle 22 GMT 13/12/2024 11:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 32 15.19 477 232 0.23 / 90.83 2 5
2 7 2006.28 38 14.86 2993 1690 1.92 / 92.52 2 13
3 13 1448.84 18 14.96 2301 620 2.54 / 93.14 2 14
4 13 931.92 18 15.06 1627 441 2.98 / 93.58 2 17
5 13 344.20 18 15.22 834 228 3.21 / 93.81 2 18
6 8 0.40 165 15.27 340 857 4.07 / 94.67 2 20
Average= 4.12
(KJ/cycle)

Cycle 21 GMT 3/12/2024 16:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 32 15.20 510 248 0.25 / 86.51 2 5
2 7 2010.84 39 14.84 3003 1738 1.99 / 88.24 2 14
3 13 1345.76 18 14.98 2180 588 2.57 / 88.83 2 15
4 13 878.80 18 15.07 1565 425 3.00 / 89.26 2 18
5 13 335.40 18 15.21 826 226 3.22 / 89.48 2 18
6 13 36.44 18 15.29 404 111 3.34 / 89.59 2 18
7 8 -0.12 165 15.25 339 853 4.19 / 90.45 2 20
8 14 -0.12 30 15.23 337 154 4.34 / 90.60 2 23
Average= 4.12
(KJ/cycle)

Cycle 20 GMT 23/11/2024 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 32 15.18 515 250 0.25 / 82.33 2 6
2 7 2016.64 38 14.84 3005 1695 1.94 / 84.03 2 12
3 13 1324.68 18 14.98 2142 578 2.52 / 84.60 2 15
4 13 849.28 18 15.07 1523 413 2.94 / 85.02 2 17
5 13 359.32 18 15.21 858 235 3.17 / 85.25 2 18
6 8 -0.08 165 15.26 339 854 4.02 / 86.11 2 24
7 14 -0.08 30 15.24 333 152 4.18 / 86.26 2 20
Average= 4.11
(KJ/cycle)

Cycle 19 GMT 14/11/2024 2:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 32 15.21 501 244 0.24 / 78.05 2 6
2 7 2003.64 38 14.85 2989 1687 1.93 / 79.73 2 11
3 13 1388.84 18 14.97 2230 601 2.53 / 80.33 2 15
4 13 860.24 18 15.08 1536 417 2.95 / 80.75 2 16
5 13 295.64 18 15.23 772 212 3.16 / 80.96 2 18
6 13 38.08 18 15.30 405 112 3.27 / 81.07 2 17
7 8 0.16 165 15.27 339 854 4.13 / 81.93 2 26
8 14 0.16 30 15.25 337 154 4.28 / 82.08 2 25
Average= 4.10
(KJ/cycle)

Cycle 18 GMT 4/11/2024 7: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 32 15.21 508 247 0.25 / 73.88 2 5
2 7 2013.80 38 14.87 3010 1701 1.95 / 75.58 2 14
3 13 1365.32 18 14.99 2196 593 2.54 / 76.17 2 14
4 13 884.80 18 15.08 1573 427 2.97 / 76.60 2 18
5 13 381.56 18 15.21 892 244 3.21 / 76.84 2 18
6 13 25.08 18 15.30 386 106 3.32 / 76.95 2 17
7 8 -0.12 165 15.26 338 851 4.17 / 77.80 2 22
Average= 4.09
(KJ/cycle)

Cycle 17 GMT 25/10/2024 12: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 15.21 479 233 0.23 / 69.75 2 6
2 7 2006.24 38 14.86 2995 1691 1.92 / 71.44 2 12
3 13 1352.80 18 15.00 2177 588 2.51 / 72.03 2 14
4 13 817.88 18 15.11 1477 402 2.91 / 72.43 2 17
5 13 372.68 18 15.22 874 239 3.15 / 72.67 2 18
6 13 22.40 18 15.31 380 105 3.26 / 72.78 2 18
7 8 0.08 165 15.28 339 855 4.11 / 73.63 2 26
Average= 4.09
(KJ/cycle)

Cycle 16 GMT 15/10/2024 17: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 32 15.21 485 236 0.24 / 65.61 2 5
2 7 2002.80 38 14.86 2990 1688 1.92 / 67.30 2 12
3 13 1446.92 18 14.97 2307 622 2.55 / 67.92 2 14
4 13 850.60 18 15.10 1527 415 2.96 / 68.34 2 17
5 13 322.76 18 15.24 805 221 3.18 / 68.56 2 18
6 13 27.40 18 15.31 389 107 3.29 / 68.66 2 16
7 8 0.04 165 15.26 340 856 4.15 / 69.52 2 23
Average= 4.09
(KJ/cycle)

Cycle 15 GMT 5/10/2024 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 32 15.21 492 239 0.24 / 61.48 2 4
2 7 2012.76 38 14.87 3003 1697 1.94 / 63.18 2 11
3 13 1356.92 18 15.00 2188 591 2.53 / 63.77 2 15
4 13 829.28 18 15.11 1494 406 2.93 / 64.18 2 17
5 13 332.80 18 15.24 822 225 3.16 / 64.40 2 18
6 13 34.68 18 15.32 403 111 3.27 / 64.52 2 16
7 8 -0.04 165 15.27 341 859 4.13 / 65.37 2 22
Average= 4.09
(KJ/cycle)

Cycle 14 GMT 26/ 9/2024 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 32 15.22 499 243 0.24 / 57.34 2 5
2 7 2007.52 38 14.86 2993 1690 1.93 / 59.03 2 10
3 13 1362.24 18 14.99 2194 592 2.53 / 59.62 2 16
4 13 846.16 18 15.10 1512 411 2.94 / 60.03 2 17
5 13 393.20 18 15.21 906 248 3.18 / 60.28 2 18
6 13 31.68 18 15.31 398 110 3.29 / 60.39 2 18
7 8 0.00 165 15.27 340 857 4.15 / 61.25 2 24
Average= 4.08
(KJ/cycle)

Cycle 13 GMT 16/ 9/2024 7:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.00 31 15.21 511 241 0.24 / 53.13 2 5
2 7 2004.28 39 14.88 2993 1737 1.98 / 54.87 2 14
3 13 1360.72 18 15.01 2188 591 2.57 / 55.46 2 15
4 13 881.48 18 15.11 1573 428 3.00 / 55.89 2 18
5 13 344.96 18 15.25 840 231 3.23 / 56.12 2 19
6 13 31.36 18 15.34 394 109 3.34 / 56.23 2 17
7 8 0.00 165 15.29 343 865 4.20 / 57.09 2 23
Average= 4.08
(KJ/cycle)

Cycle 12 GMT 6/ 9/2024 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 31 15.22 503 237 0.24 / 48.98 2 5
2 7 2004.04 38 14.88 2993 1692 1.93 / 50.67 2 10
3 13 1448.96 18 14.99 2298 620 2.55 / 51.29 2 13
4 13 893.28 18 15.10 1580 429 2.98 / 51.72 2 17
5 13 306.60 18 15.26 786 216 3.20 / 51.93 2 17
6 13 23.48 18 15.33 381 105 3.30 / 52.04 2 18
7 8 0.08 165 15.28 339 855 4.15 / 52.89 2 24
Average= 4.07
(KJ/cycle)

Cycle 11 GMT 27/ 8/2024 17:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 31 15.23 500 236 0.24 / 44.78 2 5
2 7 2004.24 38 14.88 3003 1698 1.93 / 46.48 2 15
3 13 1422.24 18 14.99 2280 615 2.55 / 47.09 2 14
4 13 876.56 18 15.10 1558 423 2.97 / 47.52 2 17
5 13 378.56 18 15.24 891 244 3.22 / 47.76 2 18
6 13 19.48 18 15.33 381 105 3.32 / 47.87 2 18
7 8 0.08 165 15.29 345 870 4.19 / 48.74 2 26
Average= 4.06
(KJ/cycle)

Cycle 10 GMT 17/ 8/2024 22:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 31 15.23 499 236 0.24 / 40.61 2 4
2 7 2008.40 38 14.90 2997 1697 1.93 / 42.31 2 11
3 13 1416.12 18 15.01 2268 613 2.55 / 42.92 2 14
4 13 870.88 18 15.12 1550 422 2.97 / 43.34 2 16
5 13 339.96 18 15.26 829 228 3.19 / 43.57 2 18
6 13 23.20 18 15.34 382 105 3.30 / 43.68 2 18
7 8 0.20 165 15.29 345 870 4.17 / 44.55 2 25
Average= 4.05
(KJ/cycle)

Cycle 9 GMT 8/ 8/2024 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 30 15.24 498 228 0.23 / 35.74 2 4
2 3 1037.48 1 15.26 1851 28 0.26 / 35.77 2 13
3 7 2006.48 75 14.77 2988 3310 3.57 / 39.08 2 11
4 13 582.08 18 15.19 1163 318 3.88 / 39.39 2 18
5 13 43.56 18 15.33 416 115 4.00 / 39.51 2 18
6 8 -0.12 165 15.29 343 865 4.86 / 40.37 2 25
Average= 4.04
(KJ/cycle)

Cycle 8 GMT 29/ 7/2024 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 29 15.23 513 227 0.23 / 30.92 2 6
2 10 1021.20 2 15.20 1807 55 0.28 / 30.97 2 10
3 3 972.32 -1 15.64 0 0 0.05 / 30.97 2 10
4 7 2004.56 74 14.77 2973 3249 3.53 / 34.22 2 11
5 13 592.08 18 15.18 1175 321 3.85 / 34.54 2 18
6 13 42.40 18 15.34 409 113 3.96 / 34.66 2 17
7 8 0.04 165 15.30 339 856 4.82 / 35.51 2 23
Average= 3.95
(KJ/cycle)

Cycle 7 GMT 19/ 7/2024 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 30 15.23 508 232 0.23 / 26.43 2 5
2 7 1811.80 74 14.83 2737 3004 3.24 / 29.43 2 11
3 13 494.36 18 15.22 1040 285 3.52 / 29.71 2 17
4 13 22.48 18 15.34 383 106 3.63 / 29.82 2 18
5 8 0.12 165 15.29 345 870 4.50 / 30.69 2 24
Average= 3.84
(KJ/cycle)

Cycle 6 GMT 18/ 7/2024 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 15.22 483 221 0.22 / 21.87 2 6
2 3 1016.60 1 15.29 1819 28 0.25 / 21.90 2 12
3 7 1812.52 74 14.83 2748 3016 3.26 / 24.91 2 11
4 13 535.88 18 15.20 1098 300 3.56 / 25.21 2 18
5 13 18.40 18 15.34 381 105 3.67 / 25.32 2 18
6 8 0.20 165 15.29 347 875 4.55 / 26.19 2 25
Average= 3.74
(KJ/cycle)

Cycle 5 GMT 17/ 7/2024 8:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 30 15.23 499 228 0.23 / 17.40 2 6
2 7 1807.08 74 14.82 2723 2986 3.21 / 20.39 2 12
3 13 527.56 18 15.20 1085 297 3.51 / 20.68 2 18
4 13 28.60 18 15.33 387 107 3.62 / 20.79 2 18
5 8 0.04 165 15.29 340 858 4.48 / 21.65 2 21
Average= 3.61
(KJ/cycle)

Cycle 4 GMT 16/ 7/2024 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 29 15.24 511 226 0.23 / 13.37 2 5
2 7 1509.00 74 14.94 2350 2598 2.82 / 15.97 2 13
3 13 406.56 18 15.24 919 252 3.08 / 16.22 2 17
4 13 18.04 18 15.34 371 102 3.18 / 16.32 2 17
5 8 -0.04 165 15.29 338 853 4.03 / 17.17 2 24
Average= 3.43
(KJ/cycle)

Cycle 3 GMT 15/ 7/2024 8:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 28 15.24 478 204 0.20 / 9.26 2 5
2 3 1044.16 1 15.26 1847 28 0.23 / 9.29 2 13
3 7 1508.64 74 14.94 2347 2595 2.83 / 11.88 2 12
4 13 475.88 18 15.23 1012 277 3.10 / 12.16 2 18
5 13 25.68 18 15.33 389 107 3.21 / 12.27 2 18
6 8 0.04 165 15.29 347 875 4.09 / 13.14 2 24
Average= 3.29
(KJ/cycle)

Cycle 2 GMT 14/ 7/2024 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 32 15.31 506 248 0.25 / 5.20 2 6
2 3 908.88 -2 15.68 0 0 0.00 / 5.20 2 6
3 3 967.68 -1 15.70 0 0 0.00 / 5.20 2 6
4 7 1526.16 75 14.94 2368 2653 2.90 / 7.85 2 12
5 13 425.04 18 15.26 933 256 3.16 / 8.11 2 18
6 13 13.56 18 15.36 361 100 3.26 / 8.21 2 18
7 8 0.04 165 15.31 336 849 4.11 / 9.05 2 23
Average= 3.02
(KJ/cycle)

Cycle 1 GMT 13/ 7/2024 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 27 15.45 462 193 0.19 / 2.14 2 3
2 10 1005.28 2 15.32 1771 54 0.25 / 2.19 2 7
3 7 1002.60 74 15.14 1686 1889 2.14 / 4.08 2 16
4 8 -0.08 165 15.37 343 870 3.01 / 4.95 2 27
Average= 2.47
(KJ/cycle)

Cycle 0 GMT 12/ 7/2024 23:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.36 26 15.61 523 212 0.21 / 0.21 2 3
2 7 169.64 74 15.58 534 616 0.83 / 0.83 2 4
3 8 0.28 240 15.53 299 1114 1.94 / 1.94 2 16
Average= 1.94
(KJ/cycle)