SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 30 | 15.11 | 447 | 203 | 0.20 / 238.23 | 2 | 3 |
2 | 7 | 2005.00 | 39 | 14.82 | 2909 | 1681 | 1.88 / 239.91 | 2 | 5 |
3 | 13 | 1836.04 | 15 | 14.84 | 2724 | 606 | 2.49 / 240.51 | 2 | 9 |
4 | 13 | 1275.36 | 15 | 14.93 | 2045 | 458 | 2.95 / 240.97 | 2 | 12 |
5 | 13 | 799.00 | 15 | 15.04 | 1434 | 324 | 3.27 / 241.30 | 2 | 11 |
6 | 13 | 268.04 | 15 | 15.18 | 712 | 162 | 3.43 / 241.46 | 2 | 10 |
7 | 13 | 118.92 | 15 | 15.20 | 493 | 112 | 3.55 / 241.57 | 2 | 7 |
8 | 13 | 73.84 | 15 | 15.19 | 425 | 97 | 3.64 / 241.67 | 2 | 6 |
9 | 13 | 22.08 | 15 | 15.19 | 349 | 80 | 3.72 / 241.75 | 2 | 11 |
10 | 8 | 0.20 | 165 | 15.16 | 309 | 773 | 4.50 / 242.52 | 2 | 23 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 30 | 15.10 | 467 | 212 | 0.21 / 233.82 | 2 | 3 |
2 | 7 | 2002.36 | 38 | 14.85 | 2905 | 1639 | 1.85 / 235.46 | 2 | 7 |
3 | 13 | 1769.60 | 15 | 14.87 | 2646 | 590 | 2.44 / 236.05 | 2 | 9 |
4 | 13 | 1221.32 | 15 | 14.96 | 1974 | 443 | 2.88 / 236.49 | 2 | 10 |
5 | 13 | 710.92 | 15 | 15.07 | 1322 | 299 | 3.18 / 236.79 | 2 | 11 |
6 | 13 | 349.24 | 15 | 15.16 | 829 | 189 | 3.37 / 236.98 | 2 | 13 |
7 | 13 | 113.80 | 15 | 15.21 | 489 | 112 | 3.48 / 237.09 | 2 | 16 |
8 | 13 | 78.72 | 15 | 15.20 | 431 | 98 | 3.58 / 237.19 | 2 | 13 |
9 | 13 | 23.12 | 15 | 15.20 | 348 | 79 | 3.66 / 237.27 | 2 | 7 |
10 | 8 | -0.44 | 165 | 15.16 | 301 | 753 | 4.41 / 238.02 | 2 | 13 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 30 | 15.11 | 456 | 207 | 0.21 / 229.39 | 2 | 3 |
2 | 7 | 2006.16 | 38 | 14.85 | 2913 | 1644 | 1.85 / 231.04 | 2 | 5 |
3 | 13 | 1641.32 | 15 | 14.90 | 2496 | 558 | 2.41 / 231.60 | 2 | 9 |
4 | 13 | 1244.08 | 15 | 14.96 | 2008 | 451 | 2.86 / 232.05 | 2 | 9 |
5 | 13 | 721.96 | 15 | 15.09 | 1336 | 302 | 3.16 / 232.35 | 2 | 11 |
6 | 13 | 300.76 | 15 | 15.18 | 757 | 172 | 3.33 / 232.52 | 2 | 11 |
7 | 13 | 128.76 | 15 | 15.22 | 511 | 117 | 3.45 / 232.64 | 2 | 12 |
8 | 13 | 83.76 | 15 | 15.20 | 447 | 102 | 3.55 / 232.74 | 2 | 18 |
9 | 13 | 46.48 | 15 | 15.20 | 393 | 90 | 3.64 / 232.83 | 2 | 6 |
10 | 8 | 0.24 | 165 | 15.16 | 312 | 780 | 4.42 / 233.61 | 2 | 11 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 30 | 15.10 | 456 | 207 | 0.21 / 224.95 | 2 | 3 |
2 | 7 | 2014.16 | 38 | 14.85 | 2906 | 1640 | 1.85 / 226.59 | 2 | 8 |
3 | 13 | 1568.16 | 15 | 14.92 | 2390 | 535 | 2.38 / 227.13 | 2 | 8 |
4 | 13 | 1340.84 | 15 | 14.94 | 2108 | 472 | 2.85 / 227.60 | 2 | 9 |
5 | 13 | 712.60 | 15 | 15.08 | 1319 | 298 | 3.15 / 227.90 | 2 | 10 |
6 | 13 | 427.48 | 15 | 15.14 | 939 | 213 | 3.37 / 228.11 | 2 | 11 |
7 | 13 | 172.52 | 15 | 15.20 | 574 | 131 | 3.50 / 228.24 | 2 | 12 |
8 | 13 | 69.16 | 15 | 15.21 | 424 | 97 | 3.59 / 228.34 | 2 | 7 |
9 | 13 | 22.08 | 15 | 15.20 | 352 | 80 | 3.67 / 228.42 | 2 | 7 |
10 | 8 | -0.04 | 165 | 15.17 | 307 | 768 | 4.44 / 229.19 | 2 | 12 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 30 | 15.12 | 457 | 207 | 0.21 / 220.47 | 2 | 3 |
2 | 7 | 2012.36 | 38 | 14.85 | 2927 | 1652 | 1.86 / 222.12 | 2 | 7 |
3 | 13 | 1737.28 | 15 | 14.87 | 2609 | 582 | 2.44 / 222.70 | 2 | 7 |
4 | 13 | 1249.20 | 15 | 14.96 | 2016 | 452 | 2.89 / 223.15 | 2 | 9 |
5 | 13 | 761.08 | 15 | 15.07 | 1391 | 314 | 3.21 / 223.47 | 2 | 10 |
6 | 13 | 334.92 | 15 | 15.18 | 817 | 186 | 3.39 / 223.65 | 2 | 12 |
7 | 13 | 161.68 | 15 | 15.20 | 566 | 129 | 3.52 / 223.78 | 2 | 8 |
8 | 13 | 66.00 | 15 | 15.21 | 421 | 96 | 3.62 / 223.88 | 2 | 6 |
9 | 13 | 39.32 | 15 | 15.20 | 385 | 88 | 3.71 / 223.97 | 2 | 11 |
10 | 8 | -0.12 | 165 | 15.16 | 312 | 780 | 4.49 / 224.75 | 2 | 27 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 30 | 15.14 | 455 | 207 | 0.21 / 216.03 | 2 | 2 |
2 | 7 | 2003.96 | 38 | 14.85 | 2909 | 1642 | 1.85 / 217.67 | 2 | 8 |
3 | 13 | 1776.20 | 15 | 14.89 | 2665 | 595 | 2.44 / 218.26 | 2 | 8 |
4 | 13 | 1119.84 | 15 | 15.00 | 1845 | 415 | 2.86 / 218.68 | 2 | 10 |
5 | 13 | 772.72 | 15 | 15.07 | 1399 | 316 | 3.17 / 218.99 | 2 | 11 |
6 | 13 | 343.28 | 15 | 15.19 | 829 | 189 | 3.36 / 219.18 | 2 | 12 |
7 | 13 | 159.56 | 15 | 15.21 | 562 | 128 | 3.49 / 219.31 | 2 | 12 |
8 | 13 | 80.00 | 15 | 15.21 | 443 | 101 | 3.59 / 219.41 | 2 | 12 |
9 | 13 | 22.12 | 15 | 15.20 | 354 | 81 | 3.67 / 219.49 | 2 | 8 |
10 | 8 | -0.64 | 165 | 15.17 | 306 | 766 | 4.44 / 220.26 | 2 | 14 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 30 | 15.12 | 453 | 205 | 0.21 / 211.58 | 2 | 3 |
2 | 7 | 2006.00 | 38 | 14.86 | 2911 | 1644 | 1.85 / 213.22 | 2 | 8 |
3 | 13 | 1843.68 | 15 | 14.87 | 2735 | 610 | 2.46 / 213.83 | 2 | 8 |
4 | 13 | 1240.20 | 15 | 14.98 | 2003 | 450 | 2.91 / 214.28 | 2 | 9 |
5 | 13 | 687.96 | 15 | 15.10 | 1289 | 292 | 3.20 / 214.57 | 2 | 12 |
6 | 13 | 272.00 | 15 | 15.21 | 720 | 164 | 3.37 / 214.74 | 2 | 10 |
7 | 13 | 117.96 | 15 | 15.23 | 502 | 115 | 3.48 / 214.85 | 2 | 12 |
8 | 13 | 85.88 | 15 | 15.22 | 450 | 103 | 3.58 / 214.96 | 2 | 6 |
9 | 13 | 49.96 | 15 | 15.22 | 393 | 90 | 3.67 / 215.05 | 2 | 9 |
10 | 8 | 0.20 | 165 | 15.18 | 309 | 774 | 4.45 / 215.82 | 2 | 27 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 30 | 15.13 | 454 | 206 | 0.21 / 207.02 | 2 | 3 |
2 | 7 | 2010.92 | 38 | 14.86 | 2933 | 1656 | 1.86 / 208.67 | 2 | 9 |
3 | 13 | 1957.04 | 15 | 14.86 | 2881 | 642 | 2.50 / 209.32 | 2 | 7 |
4 | 13 | 1305.76 | 15 | 14.97 | 2083 | 468 | 2.97 / 209.78 | 2 | 8 |
5 | 13 | 928.24 | 15 | 15.04 | 1608 | 363 | 3.33 / 210.15 | 2 | 10 |
6 | 13 | 257.76 | 15 | 15.21 | 701 | 160 | 3.49 / 210.31 | 2 | 12 |
7 | 13 | 107.60 | 15 | 15.23 | 481 | 110 | 3.60 / 210.42 | 2 | 12 |
8 | 13 | 72.12 | 15 | 15.23 | 426 | 97 | 3.70 / 210.51 | 2 | 14 |
9 | 13 | 40.32 | 15 | 15.21 | 382 | 87 | 3.79 / 210.60 | 2 | 10 |
10 | 8 | 0.40 | 165 | 15.18 | 308 | 771 | 4.56 / 211.37 | 2 | 30 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 30 | 15.14 | 448 | 203 | 0.20 / 202.67 | 2 | 3 |
2 | 7 | 2007.04 | 38 | 14.86 | 2920 | 1649 | 1.85 / 204.32 | 2 | 9 |
3 | 13 | 1556.88 | 15 | 14.94 | 2395 | 537 | 2.39 / 204.86 | 2 | 9 |
4 | 13 | 1329.48 | 15 | 14.95 | 2111 | 473 | 2.86 / 205.33 | 2 | 8 |
5 | 13 | 779.28 | 15 | 15.08 | 1410 | 319 | 3.18 / 205.65 | 2 | 11 |
6 | 13 | 250.12 | 15 | 15.21 | 691 | 158 | 3.34 / 205.81 | 2 | 11 |
7 | 13 | 143.56 | 15 | 15.23 | 541 | 124 | 3.46 / 205.93 | 2 | 10 |
8 | 13 | 92.68 | 15 | 15.23 | 464 | 106 | 3.57 / 206.03 | 2 | 11 |
9 | 8 | 0.08 | 165 | 15.19 | 310 | 777 | 4.35 / 206.81 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 30 | 15.15 | 455 | 207 | 0.21 / 198.23 | 2 | 3 |
2 | 7 | 2009.60 | 39 | 14.86 | 2929 | 1697 | 1.90 / 199.93 | 2 | 8 |
3 | 13 | 1668.20 | 15 | 14.92 | 2538 | 568 | 2.47 / 200.49 | 2 | 12 |
4 | 13 | 1137.28 | 15 | 15.01 | 1875 | 422 | 2.89 / 200.92 | 2 | 12 |
5 | 13 | 788.44 | 15 | 15.08 | 1420 | 321 | 3.22 / 201.24 | 2 | 10 |
6 | 13 | 266.04 | 15 | 15.21 | 713 | 163 | 3.38 / 201.40 | 2 | 10 |
7 | 13 | 113.52 | 15 | 15.23 | 488 | 111 | 3.49 / 201.51 | 2 | 7 |
8 | 13 | 68.20 | 15 | 15.23 | 421 | 96 | 3.59 / 201.61 | 2 | 16 |
9 | 13 | 37.96 | 15 | 15.22 | 378 | 86 | 3.67 / 201.69 | 2 | 9 |
10 | 8 | 0.00 | 165 | 15.18 | 308 | 771 | 4.44 / 202.47 | 2 | 29 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 30 | 15.13 | 461 | 209 | 0.21 / 193.93 | 2 | 3 |
2 | 7 | 2003.52 | 38 | 14.86 | 2916 | 1647 | 1.86 / 195.58 | 2 | 10 |
3 | 13 | 1654.72 | 15 | 14.92 | 2527 | 566 | 2.42 / 196.14 | 2 | 10 |
4 | 13 | 1122.36 | 15 | 15.02 | 1860 | 419 | 2.84 / 196.56 | 2 | 8 |
5 | 13 | 721.88 | 15 | 15.11 | 1346 | 305 | 3.15 / 196.86 | 2 | 10 |
6 | 13 | 259.84 | 15 | 15.22 | 712 | 163 | 3.31 / 197.03 | 2 | 12 |
7 | 13 | 104.08 | 15 | 15.24 | 483 | 110 | 3.42 / 197.14 | 2 | 10 |
8 | 13 | 60.20 | 15 | 15.23 | 417 | 95 | 3.51 / 197.23 | 2 | 8 |
9 | 8 | -0.36 | 165 | 15.19 | 315 | 790 | 4.30 / 198.02 | 2 | 18 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 30 | 15.15 | 457 | 208 | 0.21 / 189.52 | 2 | 3 |
2 | 7 | 2009.60 | 38 | 14.87 | 2925 | 1653 | 1.86 / 191.17 | 2 | 5 |
3 | 13 | 1668.80 | 15 | 14.92 | 2534 | 567 | 2.43 / 191.74 | 2 | 8 |
4 | 13 | 1145.92 | 15 | 15.02 | 1883 | 424 | 2.85 / 192.16 | 2 | 10 |
5 | 13 | 733.36 | 15 | 15.11 | 1354 | 307 | 3.16 / 192.47 | 2 | 11 |
6 | 13 | 259.20 | 15 | 15.22 | 702 | 160 | 3.32 / 192.63 | 2 | 13 |
7 | 13 | 151.88 | 15 | 15.24 | 551 | 126 | 3.44 / 192.76 | 2 | 9 |
8 | 13 | 56.92 | 15 | 15.24 | 405 | 93 | 3.54 / 192.85 | 2 | 7 |
9 | 13 | 35.44 | 15 | 15.23 | 378 | 86 | 3.62 / 192.93 | 2 | 14 |
10 | 8 | -0.40 | 165 | 15.19 | 313 | 784 | 4.41 / 193.72 | 2 | 24 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 30 | 15.15 | 456 | 207 | 0.21 / 185.12 | 2 | 3 |
2 | 7 | 2003.64 | 38 | 14.89 | 2917 | 1650 | 1.86 / 186.77 | 2 | 8 |
3 | 13 | 1605.08 | 15 | 14.95 | 2457 | 551 | 2.41 / 187.32 | 2 | 7 |
4 | 13 | 1181.32 | 15 | 15.02 | 1927 | 434 | 2.84 / 187.75 | 2 | 11 |
5 | 13 | 726.72 | 15 | 15.11 | 1347 | 305 | 3.15 / 188.06 | 2 | 11 |
6 | 13 | 261.36 | 15 | 15.22 | 713 | 163 | 3.31 / 188.22 | 2 | 11 |
7 | 13 | 152.64 | 15 | 15.24 | 555 | 127 | 3.44 / 188.35 | 2 | 14 |
8 | 13 | 63.80 | 15 | 15.25 | 419 | 96 | 3.53 / 188.44 | 2 | 10 |
9 | 13 | 36.68 | 15 | 15.24 | 379 | 87 | 3.62 / 188.53 | 2 | 7 |
10 | 8 | 0.64 | 165 | 15.20 | 312 | 782 | 4.40 / 189.31 | 2 | 20 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 30 | 15.14 | 456 | 207 | 0.21 / 180.70 | 2 | 3 |
2 | 7 | 2003.32 | 38 | 14.87 | 2916 | 1648 | 1.85 / 182.34 | 2 | 8 |
3 | 13 | 1663.44 | 15 | 14.92 | 2525 | 565 | 2.42 / 182.91 | 2 | 9 |
4 | 13 | 1186.24 | 15 | 15.01 | 1939 | 437 | 2.86 / 183.34 | 2 | 10 |
5 | 13 | 720.40 | 15 | 15.11 | 1347 | 305 | 3.16 / 183.65 | 2 | 11 |
6 | 13 | 253.32 | 15 | 15.23 | 707 | 162 | 3.32 / 183.81 | 2 | 13 |
7 | 13 | 143.40 | 15 | 15.25 | 545 | 125 | 3.45 / 183.94 | 2 | 13 |
8 | 13 | 92.72 | 15 | 15.24 | 464 | 106 | 3.55 / 184.04 | 2 | 8 |
9 | 13 | 28.12 | 15 | 15.24 | 366 | 84 | 3.64 / 184.13 | 2 | 16 |
10 | 8 | 0.72 | 165 | 15.19 | 312 | 782 | 4.42 / 184.91 | 2 | 8 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 30 | 15.15 | 466 | 212 | 0.21 / 176.22 | 2 | 2 |
2 | 7 | 2006.28 | 38 | 14.86 | 2916 | 1647 | 1.86 / 177.87 | 2 | 9 |
3 | 13 | 1770.12 | 15 | 14.90 | 2656 | 594 | 2.45 / 178.46 | 2 | 6 |
4 | 13 | 1231.80 | 15 | 14.98 | 1994 | 448 | 2.90 / 178.91 | 2 | 9 |
5 | 13 | 754.00 | 15 | 15.09 | 1383 | 313 | 3.21 / 179.22 | 2 | 11 |
6 | 13 | 340.72 | 15 | 15.19 | 822 | 187 | 3.40 / 179.41 | 2 | 12 |
7 | 13 | 121.68 | 15 | 15.24 | 501 | 115 | 3.51 / 179.53 | 2 | 16 |
8 | 13 | 78.16 | 15 | 15.23 | 435 | 99 | 3.61 / 179.63 | 2 | 12 |
9 | 13 | 21.68 | 15 | 15.23 | 353 | 81 | 3.69 / 179.71 | 2 | 15 |
10 | 8 | 0.68 | 165 | 15.18 | 312 | 781 | 4.48 / 180.49 | 2 | 12 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 30 | 15.15 | 450 | 205 | 0.20 / 171.80 | 2 | 2 |
2 | 7 | 2003.16 | 38 | 14.88 | 2916 | 1649 | 1.85 / 173.45 | 2 | 4 |
3 | 13 | 1507.28 | 15 | 14.96 | 2332 | 523 | 2.38 / 173.98 | 2 | 9 |
4 | 13 | 1280.12 | 15 | 14.98 | 2061 | 463 | 2.84 / 174.44 | 2 | 9 |
5 | 13 | 740.48 | 15 | 15.11 | 1366 | 310 | 3.15 / 174.75 | 2 | 10 |
6 | 13 | 316.68 | 15 | 15.21 | 792 | 181 | 3.33 / 174.93 | 2 | 11 |
7 | 13 | 138.80 | 15 | 15.24 | 532 | 122 | 3.45 / 175.05 | 2 | 14 |
8 | 13 | 57.20 | 15 | 15.24 | 409 | 93 | 3.55 / 175.14 | 2 | 19 |
9 | 13 | 32.20 | 15 | 15.24 | 372 | 85 | 3.63 / 175.23 | 2 | 9 |
10 | 8 | 0.24 | 165 | 15.19 | 312 | 782 | 4.41 / 176.01 | 2 | 9 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 30 | 15.15 | 455 | 207 | 0.21 / 167.26 | 2 | 3 |
2 | 7 | 2005.80 | 39 | 14.87 | 2928 | 1698 | 1.90 / 168.96 | 2 | 5 |
3 | 13 | 1835.24 | 15 | 14.88 | 2742 | 612 | 2.52 / 169.57 | 2 | 6 |
4 | 13 | 1290.48 | 15 | 14.98 | 2069 | 465 | 2.98 / 170.03 | 2 | 9 |
5 | 13 | 758.48 | 15 | 15.10 | 1393 | 316 | 3.30 / 170.35 | 2 | 11 |
6 | 13 | 285.00 | 15 | 15.22 | 741 | 169 | 3.47 / 170.52 | 2 | 11 |
7 | 13 | 122.80 | 15 | 15.25 | 503 | 115 | 3.58 / 170.63 | 2 | 8 |
8 | 13 | 78.96 | 15 | 15.24 | 437 | 100 | 3.68 / 170.73 | 2 | 15 |
9 | 13 | 43.88 | 15 | 15.24 | 383 | 88 | 3.77 / 170.82 | 2 | 6 |
10 | 8 | 0.48 | 165 | 15.20 | 310 | 777 | 4.55 / 171.60 | 2 | 27 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 29 | 15.15 | 459 | 202 | 0.20 / 162.80 | 2 | 3 |
2 | 7 | 2002.96 | 38 | 14.88 | 2923 | 1653 | 1.85 / 164.45 | 2 | 8 |
3 | 13 | 1711.36 | 15 | 14.92 | 2592 | 580 | 2.43 / 165.03 | 2 | 7 |
4 | 13 | 1241.96 | 15 | 15.00 | 2012 | 453 | 2.89 / 165.49 | 2 | 9 |
5 | 13 | 718.84 | 15 | 15.10 | 1339 | 303 | 3.19 / 165.79 | 2 | 12 |
6 | 13 | 312.56 | 15 | 15.21 | 785 | 179 | 3.37 / 165.97 | 2 | 11 |
7 | 13 | 140.52 | 15 | 15.24 | 533 | 122 | 3.49 / 166.09 | 2 | 9 |
8 | 13 | 92.00 | 15 | 15.23 | 457 | 104 | 3.60 / 166.20 | 2 | 12 |
9 | 13 | 49.48 | 15 | 15.23 | 394 | 90 | 3.69 / 166.29 | 2 | 5 |
10 | 8 | 0.56 | 165 | 15.19 | 306 | 767 | 4.45 / 167.05 | 2 | 12 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 29 | 15.14 | 462 | 203 | 0.20 / 158.31 | 2 | 3 |
2 | 7 | 2009.28 | 38 | 14.88 | 2926 | 1654 | 1.86 / 159.97 | 2 | 6 |
3 | 13 | 1718.44 | 15 | 14.92 | 2591 | 580 | 2.44 / 160.55 | 2 | 10 |
4 | 13 | 1312.16 | 15 | 14.99 | 2096 | 471 | 2.91 / 161.02 | 2 | 9 |
5 | 13 | 796.56 | 15 | 15.10 | 1435 | 325 | 3.23 / 161.34 | 2 | 12 |
6 | 13 | 307.60 | 15 | 15.21 | 782 | 178 | 3.41 / 161.52 | 2 | 11 |
7 | 13 | 140.44 | 15 | 15.24 | 535 | 122 | 3.53 / 161.64 | 2 | 12 |
8 | 13 | 93.92 | 15 | 15.24 | 460 | 105 | 3.64 / 161.75 | 2 | 6 |
9 | 13 | 25.40 | 15 | 15.24 | 359 | 82 | 3.72 / 161.83 | 2 | 6 |
10 | 8 | 0.84 | 165 | 15.20 | 307 | 770 | 4.49 / 162.60 | 2 | 6 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 30 | 15.15 | 457 | 208 | 0.21 / 153.87 | 2 | 3 |
2 | 7 | 2004.52 | 38 | 14.88 | 2920 | 1651 | 1.86 / 155.52 | 2 | 8 |
3 | 13 | 1715.96 | 15 | 14.93 | 2594 | 581 | 2.44 / 156.10 | 2 | 10 |
4 | 13 | 1233.32 | 15 | 15.01 | 2001 | 451 | 2.89 / 156.55 | 2 | 8 |
5 | 13 | 759.68 | 15 | 15.11 | 1387 | 314 | 3.20 / 156.87 | 2 | 11 |
6 | 13 | 227.12 | 15 | 15.24 | 669 | 153 | 3.36 / 157.02 | 2 | 10 |
7 | 13 | 125.88 | 15 | 15.24 | 517 | 118 | 3.48 / 157.14 | 2 | 13 |
8 | 13 | 84.32 | 15 | 15.24 | 450 | 103 | 3.58 / 157.24 | 2 | 16 |
9 | 13 | 23.16 | 15 | 15.25 | 359 | 82 | 3.66 / 157.32 | 2 | 25 |
10 | 8 | -0.20 | 165 | 15.20 | 314 | 788 | 4.45 / 158.11 | 2 | 5 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.72 | 30 | 15.16 | 451 | 205 | 0.21 / 149.38 | 2 | 3 |
2 | 7 | 2005.76 | 39 | 14.88 | 2920 | 1695 | 1.90 / 151.07 | 2 | 4 |
3 | 13 | 1715.72 | 15 | 14.92 | 2597 | 581 | 2.48 / 151.65 | 2 | 12 |
4 | 13 | 1178.04 | 15 | 15.02 | 1930 | 435 | 2.92 / 152.09 | 2 | 10 |
5 | 13 | 772.40 | 15 | 15.11 | 1409 | 319 | 3.24 / 152.41 | 2 | 12 |
6 | 13 | 282.24 | 15 | 15.23 | 745 | 170 | 3.41 / 152.58 | 2 | 11 |
7 | 13 | 126.44 | 15 | 15.25 | 517 | 118 | 3.52 / 152.70 | 2 | 11 |
8 | 13 | 82.92 | 15 | 15.24 | 449 | 103 | 3.63 / 152.80 | 2 | 6 |
9 | 13 | 25.00 | 15 | 15.23 | 363 | 83 | 3.71 / 152.88 | 2 | 4 |
10 | 8 | -0.08 | 165 | 15.21 | 310 | 778 | 4.49 / 153.66 | 2 | 25 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 30 | 15.16 | 456 | 207 | 0.21 / 145.32 | 2 | 2 |
2 | 7 | 2004.12 | 39 | 14.88 | 2926 | 1698 | 1.91 / 147.02 | 2 | 7 |
3 | 13 | 1344.00 | 18 | 14.99 | 2125 | 573 | 2.48 / 147.59 | 2 | 12 |
4 | 13 | 769.64 | 18 | 15.12 | 1403 | 382 | 2.86 / 147.98 | 2 | 10 |
5 | 13 | 265.96 | 18 | 15.24 | 712 | 195 | 3.06 / 148.17 | 2 | 12 |
6 | 13 | 127.40 | 18 | 15.25 | 509 | 140 | 3.20 / 148.31 | 2 | 7 |
7 | 13 | 55.84 | 18 | 15.25 | 393 | 108 | 3.30 / 148.42 | 2 | 3 |
8 | 8 | -0.12 | 165 | 15.21 | 301 | 755 | 4.06 / 149.17 | 2 | 29 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 30 | 15.17 | 460 | 209 | 0.21 / 141.34 | 2 | 2 |
2 | 7 | 2003.88 | 38 | 14.88 | 2925 | 1654 | 1.86 / 142.99 | 2 | 7 |
3 | 13 | 1311.12 | 18 | 15.01 | 2093 | 565 | 2.43 / 143.55 | 2 | 12 |
4 | 13 | 769.08 | 18 | 15.12 | 1399 | 381 | 2.81 / 143.94 | 2 | 9 |
5 | 13 | 235.84 | 18 | 15.24 | 671 | 184 | 2.99 / 144.12 | 2 | 11 |
6 | 13 | 112.96 | 18 | 15.26 | 486 | 133 | 3.13 / 144.25 | 2 | 5 |
7 | 13 | 43.72 | 18 | 15.25 | 379 | 104 | 3.23 / 144.36 | 2 | 5 |
8 | 8 | -0.16 | 165 | 15.21 | 302 | 758 | 3.99 / 145.11 | 2 | 14 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 30 | 15.18 | 456 | 208 | 0.21 / 137.31 | 2 | 2 |
2 | 7 | 2005.68 | 39 | 14.87 | 2924 | 1696 | 1.90 / 139.01 | 2 | 9 |
3 | 13 | 1305.00 | 18 | 15.01 | 2075 | 561 | 2.46 / 139.57 | 2 | 11 |
4 | 13 | 699.16 | 18 | 15.14 | 1301 | 355 | 2.82 / 139.92 | 2 | 11 |
5 | 13 | 305.04 | 18 | 15.24 | 766 | 210 | 3.03 / 140.13 | 2 | 11 |
6 | 13 | 113.96 | 18 | 15.26 | 482 | 132 | 3.16 / 140.27 | 2 | 9 |
7 | 13 | 45.24 | 18 | 15.25 | 377 | 103 | 3.26 / 140.37 | 2 | 15 |
8 | 8 | -0.36 | 165 | 15.22 | 301 | 756 | 4.02 / 141.13 | 2 | 33 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 30 | 15.18 | 450 | 205 | 0.20 / 133.29 | 2 | 3 |
2 | 7 | 2005.08 | 38 | 14.89 | 2928 | 1657 | 1.86 / 134.95 | 2 | 8 |
3 | 13 | 1284.84 | 18 | 15.02 | 2063 | 558 | 2.42 / 135.51 | 2 | 8 |
4 | 13 | 812.88 | 18 | 15.12 | 1461 | 398 | 2.82 / 135.90 | 2 | 11 |
5 | 13 | 256.52 | 18 | 15.24 | 701 | 192 | 3.01 / 136.10 | 2 | 11 |
6 | 13 | 129.72 | 18 | 15.25 | 512 | 141 | 3.15 / 136.24 | 2 | 11 |
7 | 13 | 58.20 | 18 | 15.25 | 396 | 109 | 3.26 / 136.34 | 2 | 5 |
8 | 8 | 0.20 | 165 | 15.22 | 303 | 761 | 4.02 / 137.11 | 2 | 5 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 30 | 15.17 | 454 | 207 | 0.21 / 129.28 | 2 | 2 |
2 | 7 | 2013.96 | 38 | 14.90 | 2935 | 1662 | 1.87 / 130.94 | 2 | 7 |
3 | 13 | 1317.96 | 18 | 15.03 | 2102 | 569 | 2.44 / 131.51 | 2 | 9 |
4 | 13 | 705.44 | 18 | 15.15 | 1320 | 360 | 2.80 / 131.87 | 2 | 9 |
5 | 13 | 263.84 | 18 | 15.26 | 718 | 197 | 2.99 / 132.07 | 2 | 11 |
6 | 13 | 131.24 | 18 | 15.27 | 515 | 142 | 3.14 / 132.21 | 2 | 14 |
7 | 13 | 57.36 | 18 | 15.27 | 401 | 110 | 3.25 / 132.32 | 2 | 5 |
8 | 8 | 0.52 | 165 | 15.23 | 306 | 769 | 4.02 / 133.09 | 2 | 10 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 30 | 15.19 | 459 | 209 | 0.21 / 125.20 | 2 | 2 |
2 | 7 | 2004.56 | 39 | 14.91 | 2925 | 1701 | 1.91 / 126.91 | 2 | 5 |
3 | 13 | 1340.44 | 18 | 15.02 | 2135 | 577 | 2.49 / 127.48 | 2 | 8 |
4 | 13 | 732.24 | 18 | 15.15 | 1352 | 369 | 2.86 / 127.85 | 2 | 11 |
5 | 13 | 240.56 | 18 | 15.27 | 683 | 188 | 3.04 / 128.04 | 2 | 10 |
6 | 13 | 115.56 | 18 | 15.26 | 493 | 135 | 3.18 / 128.17 | 2 | 11 |
7 | 13 | 78.92 | 18 | 15.27 | 436 | 120 | 3.30 / 128.29 | 2 | 6 |
8 | 8 | 0.12 | 165 | 15.23 | 309 | 777 | 4.08 / 129.07 | 2 | 18 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 30 | 15.18 | 453 | 206 | 0.21 / 121.21 | 2 | 3 |
2 | 7 | 2002.20 | 38 | 14.90 | 2918 | 1652 | 1.86 / 122.86 | 2 | 8 |
3 | 13 | 1282.84 | 18 | 15.03 | 2063 | 558 | 2.42 / 123.42 | 2 | 12 |
4 | 13 | 727.32 | 18 | 15.14 | 1345 | 367 | 2.78 / 123.78 | 2 | 9 |
5 | 13 | 216.56 | 18 | 15.27 | 648 | 178 | 2.96 / 123.96 | 2 | 9 |
6 | 13 | 138.72 | 18 | 15.26 | 533 | 146 | 3.11 / 124.11 | 2 | 7 |
7 | 13 | 60.80 | 18 | 15.26 | 411 | 113 | 3.22 / 124.22 | 2 | 10 |
8 | 8 | 0.08 | 165 | 15.22 | 309 | 776 | 4.00 / 125.00 | 2 | 3 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 30 | 15.19 | 461 | 210 | 0.21 / 117.18 | 2 | 2 |
2 | 7 | 2006.68 | 38 | 14.91 | 2922 | 1656 | 1.87 / 118.84 | 2 | 9 |
3 | 13 | 1305.08 | 18 | 15.03 | 2089 | 565 | 2.43 / 119.40 | 2 | 8 |
4 | 13 | 726.40 | 18 | 15.16 | 1349 | 368 | 2.80 / 119.77 | 2 | 10 |
5 | 13 | 221.04 | 18 | 15.28 | 659 | 181 | 2.98 / 119.95 | 2 | 11 |
6 | 13 | 135.76 | 18 | 15.28 | 533 | 147 | 3.13 / 120.10 | 2 | 12 |
7 | 13 | 63.40 | 18 | 15.27 | 418 | 115 | 3.24 / 120.21 | 2 | 8 |
8 | 8 | -0.04 | 165 | 15.23 | 312 | 784 | 4.03 / 121.00 | 2 | 10 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 30 | 15.19 | 447 | 204 | 0.20 / 112.99 | 2 | 3 |
2 | 3 | 986.36 | -1 | 15.58 | 0 | 0 | 0.00 / 112.99 | 2 | 3 |
3 | 3 | 1020.76 | 1 | 15.29 | 1768 | 27 | 0.23 / 113.02 | 2 | 7 |
4 | 7 | 2005.36 | 38 | 14.91 | 2923 | 1656 | 1.89 / 114.67 | 2 | 11 |
5 | 13 | 1417.48 | 18 | 15.01 | 2227 | 602 | 2.49 / 115.27 | 2 | 12 |
6 | 13 | 1030.60 | 18 | 15.07 | 1741 | 472 | 2.96 / 115.75 | 2 | 11 |
7 | 13 | 252.72 | 18 | 15.27 | 699 | 192 | 3.15 / 115.94 | 2 | 9 |
8 | 13 | 128.48 | 18 | 15.28 | 519 | 143 | 3.30 / 116.08 | 2 | 7 |
9 | 13 | 62.56 | 18 | 15.27 | 413 | 114 | 3.41 / 116.19 | 2 | 11 |
10 | 8 | -0.20 | 165 | 15.24 | 310 | 780 | 4.19 / 116.97 | 2 | 23 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 29 | 15.19 | 459 | 202 | 0.20 / 108.95 | 2 | 3 |
2 | 7 | 2012.68 | 38 | 14.91 | 2924 | 1657 | 1.86 / 110.61 | 2 | 9 |
3 | 13 | 1392.96 | 18 | 15.02 | 2195 | 593 | 2.45 / 111.20 | 2 | 9 |
4 | 13 | 735.60 | 18 | 15.15 | 1359 | 371 | 2.82 / 111.57 | 2 | 10 |
5 | 13 | 217.64 | 18 | 15.28 | 651 | 179 | 3.00 / 111.75 | 2 | 11 |
6 | 13 | 139.28 | 18 | 15.28 | 534 | 147 | 3.15 / 111.90 | 2 | 10 |
7 | 13 | 60.08 | 18 | 15.28 | 410 | 113 | 3.26 / 112.01 | 2 | 8 |
8 | 8 | -0.20 | 165 | 15.23 | 309 | 777 | 4.04 / 112.78 | 2 | 12 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 29 | 15.19 | 460 | 203 | 0.20 / 104.91 | 2 | 3 |
2 | 7 | 2004.72 | 38 | 14.90 | 2927 | 1657 | 1.86 / 106.57 | 2 | 7 |
3 | 13 | 1353.84 | 18 | 15.03 | 2152 | 582 | 2.44 / 107.15 | 2 | 9 |
4 | 13 | 794.12 | 18 | 15.14 | 1430 | 390 | 2.83 / 107.54 | 2 | 12 |
5 | 13 | 208.80 | 18 | 15.28 | 632 | 174 | 3.01 / 107.71 | 2 | 11 |
6 | 13 | 122.00 | 18 | 15.29 | 509 | 140 | 3.15 / 107.85 | 2 | 8 |
7 | 13 | 44.16 | 18 | 15.28 | 388 | 107 | 3.25 / 107.96 | 2 | 11 |
8 | 8 | 0.56 | 165 | 15.24 | 313 | 787 | 4.04 / 108.75 | 2 | 28 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 29 | 15.20 | 463 | 204 | 0.20 / 100.87 | 2 | 3 |
2 | 7 | 2009.28 | 38 | 14.91 | 2935 | 1663 | 1.87 / 102.54 | 2 | 5 |
3 | 13 | 1330.80 | 18 | 15.03 | 2124 | 575 | 2.44 / 103.11 | 2 | 10 |
4 | 13 | 754.20 | 18 | 15.14 | 1383 | 377 | 2.82 / 103.49 | 2 | 9 |
5 | 13 | 240.72 | 18 | 15.27 | 683 | 188 | 3.01 / 103.68 | 2 | 9 |
6 | 13 | 112.00 | 18 | 15.29 | 494 | 136 | 3.14 / 103.81 | 2 | 12 |
7 | 13 | 40.68 | 18 | 15.28 | 383 | 105 | 3.25 / 103.92 | 2 | 5 |
8 | 8 | 0.84 | 165 | 15.25 | 314 | 790 | 4.04 / 104.71 | 2 | 11 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 29 | 15.19 | 450 | 198 | 0.20 / 96.85 | 2 | 3 |
2 | 7 | 2005.36 | 38 | 14.92 | 2925 | 1658 | 1.86 / 98.51 | 2 | 7 |
3 | 13 | 1277.84 | 18 | 15.05 | 2052 | 556 | 2.41 / 99.06 | 2 | 9 |
4 | 13 | 792.00 | 18 | 15.14 | 1437 | 392 | 2.80 / 99.45 | 2 | 10 |
5 | 13 | 202.92 | 18 | 15.29 | 629 | 173 | 2.98 / 99.63 | 2 | 9 |
6 | 13 | 119.52 | 18 | 15.30 | 507 | 140 | 3.12 / 99.77 | 2 | 14 |
7 | 13 | 40.08 | 18 | 15.29 | 386 | 106 | 3.22 / 99.87 | 2 | 16 |
8 | 8 | -0.24 | 165 | 15.25 | 317 | 798 | 4.02 / 100.67 | 2 | 18 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 29 | 15.20 | 457 | 201 | 0.20 / 92.77 | 2 | 3 |
2 | 7 | 2007.92 | 38 | 14.93 | 2927 | 1661 | 1.86 / 94.43 | 2 | 12 |
3 | 13 | 1410.52 | 18 | 15.03 | 2222 | 601 | 2.46 / 95.03 | 2 | 9 |
4 | 13 | 888.36 | 18 | 15.12 | 1561 | 425 | 2.89 / 95.46 | 2 | 10 |
5 | 13 | 184.72 | 18 | 15.30 | 603 | 166 | 3.05 / 95.63 | 2 | 11 |
6 | 13 | 110.84 | 18 | 15.30 | 492 | 135 | 3.19 / 95.76 | 2 | 9 |
7 | 13 | 31.56 | 18 | 15.30 | 372 | 102 | 3.29 / 95.86 | 2 | 17 |
8 | 8 | 0.16 | 165 | 15.25 | 312 | 785 | 4.08 / 96.65 | 2 | 13 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 29 | 15.21 | 453 | 200 | 0.20 / 88.80 | 2 | 3 |
2 | 7 | 2004.48 | 38 | 14.94 | 2914 | 1654 | 1.85 / 90.45 | 2 | 7 |
3 | 13 | 1235.28 | 18 | 15.07 | 2005 | 544 | 2.40 / 91.00 | 2 | 11 |
4 | 13 | 727.00 | 18 | 15.18 | 1343 | 367 | 2.76 / 91.36 | 2 | 11 |
5 | 13 | 219.32 | 18 | 15.28 | 654 | 180 | 2.94 / 91.54 | 2 | 10 |
6 | 13 | 93.52 | 18 | 15.30 | 467 | 129 | 3.07 / 91.67 | 2 | 9 |
7 | 13 | 30.72 | 18 | 15.30 | 375 | 103 | 3.18 / 91.78 | 2 | 7 |
8 | 8 | -0.04 | 165 | 15.26 | 316 | 796 | 3.97 / 92.57 | 2 | 14 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 29 | 15.20 | 462 | 204 | 0.20 / 84.74 | 2 | 3 |
2 | 7 | 2004.52 | 39 | 14.94 | 2932 | 1708 | 1.91 / 86.45 | 2 | 6 |
3 | 13 | 1301.32 | 18 | 15.06 | 2086 | 565 | 2.48 / 87.02 | 2 | 9 |
4 | 13 | 769.40 | 18 | 15.17 | 1404 | 383 | 2.86 / 87.40 | 2 | 11 |
5 | 13 | 195.08 | 18 | 15.31 | 630 | 174 | 3.03 / 87.57 | 2 | 11 |
6 | 13 | 79.16 | 18 | 15.31 | 450 | 124 | 3.16 / 87.70 | 2 | 12 |
7 | 13 | 27.52 | 18 | 15.30 | 370 | 102 | 3.26 / 87.80 | 2 | 8 |
8 | 8 | 0.96 | 165 | 15.26 | 317 | 798 | 4.06 / 88.60 | 2 | 13 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 29 | 15.21 | 464 | 205 | 0.20 / 80.68 | 2 | 2 |
2 | 7 | 2003.52 | 38 | 14.94 | 2921 | 1658 | 1.86 / 82.34 | 2 | 6 |
3 | 13 | 1447.96 | 18 | 15.04 | 2263 | 613 | 2.48 / 82.95 | 2 | 9 |
4 | 13 | 787.16 | 18 | 15.17 | 1426 | 389 | 2.86 / 83.34 | 2 | 11 |
5 | 13 | 182.80 | 18 | 15.32 | 605 | 167 | 3.03 / 83.50 | 2 | 11 |
6 | 13 | 72.72 | 18 | 15.31 | 443 | 122 | 3.15 / 83.63 | 2 | 9 |
7 | 13 | 22.40 | 18 | 15.31 | 367 | 101 | 3.26 / 83.73 | 2 | 12 |
8 | 8 | 1.20 | 165 | 15.26 | 323 | 813 | 4.07 / 84.54 | 2 | 24 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 29 | 15.20 | 467 | 206 | 0.21 / 76.52 | 2 | 3 |
2 | 7 | 2005.40 | 38 | 14.95 | 2919 | 1658 | 1.86 / 78.18 | 2 | 7 |
3 | 13 | 1477.12 | 18 | 15.05 | 2310 | 626 | 2.49 / 78.81 | 2 | 8 |
4 | 13 | 902.08 | 18 | 15.15 | 1576 | 430 | 2.92 / 79.24 | 2 | 11 |
5 | 13 | 202.56 | 18 | 15.32 | 636 | 175 | 3.10 / 79.41 | 2 | 11 |
6 | 13 | 79.36 | 18 | 15.32 | 462 | 127 | 3.22 / 79.54 | 2 | 4 |
7 | 13 | 46.36 | 18 | 15.31 | 406 | 112 | 3.33 / 79.65 | 2 | 8 |
8 | 8 | 0.12 | 165 | 15.27 | 325 | 819 | 4.15 / 80.47 | 2 | 20 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 29 | 15.21 | 455 | 201 | 0.20 / 72.46 | 2 | 3 |
2 | 7 | 2007.64 | 38 | 14.94 | 2939 | 1669 | 1.87 / 74.13 | 2 | 9 |
3 | 13 | 1217.04 | 18 | 15.09 | 1993 | 541 | 2.41 / 74.67 | 2 | 9 |
4 | 13 | 793.04 | 18 | 15.16 | 1449 | 395 | 2.81 / 75.06 | 2 | 11 |
5 | 13 | 194.32 | 18 | 15.31 | 635 | 175 | 2.98 / 75.24 | 2 | 9 |
6 | 13 | 102.88 | 18 | 15.31 | 509 | 140 | 3.12 / 75.38 | 2 | 7 |
7 | 13 | 35.00 | 18 | 15.30 | 399 | 110 | 3.23 / 75.49 | 2 | 9 |
8 | 8 | -0.16 | 165 | 15.25 | 330 | 830 | 4.06 / 76.32 | 2 | 17 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 29 | 15.23 | 451 | 199 | 0.20 / 68.44 | 2 | 2 |
2 | 7 | 2008.08 | 38 | 14.94 | 2922 | 1659 | 1.86 / 70.10 | 2 | 7 |
3 | 13 | 1296.84 | 18 | 15.08 | 2086 | 566 | 2.42 / 70.66 | 2 | 10 |
4 | 13 | 724.04 | 18 | 15.18 | 1353 | 370 | 2.79 / 71.03 | 2 | 9 |
5 | 13 | 222.40 | 18 | 15.31 | 666 | 184 | 2.98 / 71.22 | 2 | 11 |
6 | 13 | 89.96 | 18 | 15.32 | 466 | 129 | 3.11 / 71.35 | 2 | 10 |
7 | 13 | 28.08 | 18 | 15.31 | 375 | 103 | 3.21 / 71.45 | 2 | 6 |
8 | 8 | -0.12 | 165 | 15.27 | 321 | 809 | 4.02 / 72.26 | 2 | 18 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 29 | 15.22 | 466 | 206 | 0.21 / 64.34 | 2 | 3 |
2 | 7 | 2003.56 | 38 | 14.95 | 2927 | 1663 | 1.87 / 66.01 | 2 | 7 |
3 | 13 | 1502.96 | 18 | 15.04 | 2337 | 633 | 2.50 / 66.64 | 2 | 11 |
4 | 13 | 766.32 | 18 | 15.18 | 1407 | 384 | 2.89 / 67.02 | 2 | 12 |
5 | 13 | 189.04 | 18 | 15.32 | 616 | 170 | 3.06 / 67.19 | 2 | 11 |
6 | 13 | 107.68 | 18 | 15.32 | 491 | 135 | 3.19 / 67.33 | 2 | 6 |
7 | 13 | 28.44 | 18 | 15.31 | 377 | 104 | 3.29 / 67.43 | 2 | 11 |
8 | 8 | 0.48 | 165 | 15.28 | 320 | 807 | 4.10 / 68.24 | 2 | 17 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 29 | 15.22 | 456 | 201 | 0.20 / 60.31 | 2 | 3 |
2 | 7 | 2009.68 | 38 | 14.94 | 2941 | 1670 | 1.87 / 61.98 | 2 | 6 |
3 | 13 | 1289.16 | 18 | 15.08 | 2080 | 565 | 2.44 / 62.55 | 2 | 10 |
4 | 13 | 730.80 | 18 | 15.19 | 1364 | 373 | 2.81 / 62.92 | 2 | 11 |
5 | 13 | 174.28 | 18 | 15.32 | 605 | 167 | 2.98 / 63.09 | 2 | 11 |
6 | 13 | 92.48 | 18 | 15.32 | 482 | 133 | 3.11 / 63.22 | 2 | 13 |
7 | 13 | 26.60 | 18 | 15.32 | 383 | 106 | 3.21 / 63.32 | 2 | 10 |
8 | 8 | 0.32 | 165 | 15.27 | 323 | 814 | 4.03 / 64.14 | 2 | 9 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 29 | 15.22 | 470 | 207 | 0.21 / 56.25 | 2 | 3 |
2 | 7 | 2006.88 | 38 | 14.96 | 2938 | 1670 | 1.88 / 57.92 | 2 | 7 |
3 | 13 | 1303.60 | 18 | 15.09 | 2094 | 569 | 2.45 / 58.49 | 2 | 9 |
4 | 13 | 793.24 | 18 | 15.17 | 1442 | 394 | 2.84 / 58.89 | 2 | 13 |
5 | 13 | 188.16 | 18 | 15.32 | 623 | 172 | 3.01 / 59.06 | 2 | 9 |
6 | 13 | 97.48 | 18 | 15.33 | 489 | 135 | 3.15 / 59.19 | 2 | 10 |
7 | 13 | 38.00 | 18 | 15.32 | 396 | 109 | 3.26 / 59.30 | 2 | 8 |
8 | 8 | -0.68 | 165 | 15.28 | 320 | 807 | 4.06 / 60.11 | 2 | 17 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 29 | 15.24 | 464 | 205 | 0.21 / 52.21 | 2 | 3 |
2 | 3 | 973.64 | -1 | 15.62 | 0 | 0 | 0.00 / 52.21 | 2 | 3 |
3 | 7 | 2007.44 | 38 | 14.96 | 2930 | 1666 | 1.87 / 53.87 | 2 | 6 |
4 | 13 | 1318.44 | 18 | 15.08 | 2109 | 572 | 2.44 / 54.45 | 2 | 10 |
5 | 13 | 678.56 | 18 | 15.21 | 1288 | 353 | 2.80 / 54.80 | 2 | 11 |
6 | 13 | 231.76 | 18 | 15.31 | 678 | 187 | 2.98 / 54.98 | 2 | 11 |
7 | 13 | 93.92 | 18 | 15.32 | 481 | 133 | 3.12 / 55.12 | 2 | 7 |
8 | 13 | 58.32 | 18 | 15.32 | 427 | 118 | 3.23 / 55.24 | 2 | 12 |
9 | 8 | -0.24 | 165 | 15.28 | 322 | 812 | 4.04 / 56.05 | 2 | 18 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 29 | 15.24 | 469 | 207 | 0.21 / 48.14 | 2 | 3 |
2 | 7 | 2010.44 | 38 | 14.98 | 2939 | 1673 | 1.88 / 49.82 | 2 | 7 |
3 | 13 | 1310.60 | 18 | 15.10 | 2104 | 572 | 2.45 / 50.39 | 2 | 10 |
4 | 13 | 804.92 | 18 | 15.19 | 1449 | 396 | 2.85 / 50.78 | 2 | 13 |
5 | 13 | 191.40 | 18 | 15.35 | 623 | 172 | 3.02 / 50.96 | 2 | 11 |
6 | 13 | 78.96 | 18 | 15.34 | 456 | 126 | 3.15 / 51.08 | 2 | 12 |
7 | 13 | 50.60 | 18 | 15.33 | 411 | 113 | 3.26 / 51.19 | 2 | 6 |
8 | 8 | 0.64 | 165 | 15.29 | 320 | 807 | 4.07 / 52.00 | 2 | 18 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 29 | 15.23 | 470 | 208 | 0.21 / 44.11 | 2 | 3 |
2 | 7 | 2009.84 | 38 | 14.97 | 2928 | 1666 | 1.87 / 45.77 | 2 | 7 |
3 | 13 | 1290.12 | 18 | 15.11 | 2070 | 563 | 2.44 / 46.34 | 2 | 9 |
4 | 13 | 795.92 | 18 | 15.19 | 1439 | 393 | 2.83 / 46.73 | 2 | 10 |
5 | 13 | 167.08 | 18 | 15.33 | 585 | 161 | 2.99 / 46.89 | 2 | 9 |
6 | 13 | 102.20 | 18 | 15.33 | 482 | 133 | 3.12 / 47.03 | 2 | 8 |
7 | 13 | 38.36 | 18 | 15.32 | 381 | 105 | 3.23 / 47.13 | 2 | 8 |
8 | 8 | 0.80 | 165 | 15.28 | 319 | 804 | 4.03 / 47.94 | 2 | 17 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 28 | 15.23 | 464 | 198 | 0.20 / 40.00 | 2 | 2 |
2 | 7 | 2009.76 | 38 | 14.99 | 2937 | 1673 | 1.87 / 41.68 | 2 | 6 |
3 | 13 | 1330.12 | 18 | 15.10 | 2128 | 578 | 2.45 / 42.26 | 2 | 9 |
4 | 13 | 814.28 | 18 | 15.19 | 1459 | 399 | 2.85 / 42.65 | 2 | 11 |
5 | 13 | 251.40 | 18 | 15.33 | 704 | 194 | 3.04 / 42.85 | 2 | 10 |
6 | 13 | 101.04 | 18 | 15.34 | 489 | 135 | 3.18 / 42.98 | 2 | 11 |
7 | 13 | 48.16 | 18 | 15.33 | 401 | 111 | 3.29 / 43.09 | 2 | 14 |
8 | 8 | 0.36 | 165 | 15.29 | 320 | 807 | 4.10 / 43.90 | 2 | 17 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 28 | 15.24 | 454 | 194 | 0.19 / 35.88 | 2 | 2 |
2 | 7 | 2005.76 | 38 | 14.99 | 2928 | 1668 | 1.86 / 37.55 | 2 | 12 |
3 | 13 | 1339.16 | 18 | 15.09 | 2130 | 579 | 2.44 / 38.13 | 2 | 9 |
4 | 13 | 881.00 | 18 | 15.17 | 1551 | 424 | 2.86 / 38.55 | 2 | 11 |
5 | 13 | 233.32 | 18 | 15.33 | 679 | 187 | 3.05 / 38.74 | 2 | 10 |
6 | 13 | 105.16 | 18 | 15.34 | 493 | 136 | 3.19 / 38.88 | 2 | 11 |
7 | 13 | 70.76 | 18 | 15.33 | 437 | 121 | 3.31 / 39.00 | 2 | 14 |
8 | 8 | -0.60 | 165 | 15.28 | 321 | 809 | 4.12 / 39.81 | 2 | 18 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 27 | 15.24 | 463 | 191 | 0.19 / 31.07 | 2 | 3 |
2 | 10 | 1017.20 | 2 | 15.29 | 1764 | 54 | 0.24 / 31.13 | 2 | 8 |
3 | 7 | 2004.88 | 74 | 14.86 | 2909 | 3199 | 3.44 / 34.33 | 2 | 9 |
4 | 13 | 493.52 | 18 | 15.26 | 1044 | 287 | 3.73 / 34.61 | 2 | 12 |
5 | 13 | 139.88 | 18 | 15.34 | 543 | 150 | 3.88 / 34.76 | 2 | 11 |
6 | 13 | 60.28 | 18 | 15.34 | 421 | 116 | 4.00 / 34.88 | 2 | 11 |
7 | 8 | -0.12 | 165 | 15.29 | 321 | 810 | 4.81 / 35.69 | 2 | 17 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 29 | 15.29 | 459 | 204 | 0.20 / 26.17 | 2 | 3 |
2 | 3 | 937.64 | -1 | 15.69 | 0 | 0 | 0.00 / 26.17 | 2 | 3 |
3 | 3 | 967.68 | -1 | 15.70 | 0 | 0 | 0.00 / 26.17 | 2 | 3 |
4 | 7 | 2008.32 | 74 | 14.87 | 2912 | 3204 | 3.41 / 29.38 | 2 | 9 |
5 | 13 | 601.08 | 18 | 15.24 | 1188 | 326 | 3.73 / 29.70 | 2 | 12 |
6 | 13 | 141.80 | 18 | 15.34 | 547 | 151 | 3.88 / 29.86 | 2 | 12 |
7 | 13 | 58.48 | 18 | 15.34 | 417 | 115 | 4.00 / 29.97 | 2 | 11 |
8 | 13 | 16.44 | 18 | 15.33 | 353 | 97 | 4.10 / 30.07 | 2 | 12 |
9 | 8 | 1.16 | 165 | 15.29 | 323 | 815 | 4.91 / 30.88 | 2 | 18 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 27 | 15.29 | 451 | 186 | 0.19 / 22.76 | 2 | 3 |
2 | 7 | 1208.60 | 74 | 15.18 | 1925 | 2162 | 2.35 / 24.93 | 2 | 12 |
3 | 13 | 99.32 | 18 | 15.42 | 479 | 133 | 2.48 / 25.06 | 2 | 11 |
4 | 13 | 26.92 | 18 | 15.41 | 373 | 103 | 2.58 / 25.16 | 2 | 11 |
5 | 8 | 0.20 | 165 | 15.37 | 319 | 809 | 3.39 / 25.97 | 2 | 21 |
Average= | 3.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 27 | 15.28 | 458 | 189 | 0.19 / 19.38 | 2 | 3 |
2 | 7 | 1223.12 | 74 | 15.17 | 1943 | 2181 | 2.37 / 21.56 | 2 | 12 |
3 | 13 | 73.08 | 18 | 15.41 | 436 | 121 | 2.49 / 21.68 | 2 | 10 |
4 | 13 | 24.48 | 18 | 15.39 | 365 | 101 | 2.59 / 21.78 | 2 | 11 |
5 | 8 | 0.68 | 165 | 15.35 | 315 | 798 | 3.39 / 22.58 | 2 | 20 |
Average= | 3.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 27 | 15.28 | 460 | 190 | 0.19 / 15.79 | 2 | 2 |
2 | 7 | 1352.44 | 74 | 15.11 | 2101 | 2349 | 2.54 / 18.14 | 2 | 10 |
3 | 13 | 115.36 | 18 | 15.39 | 506 | 140 | 2.68 / 18.28 | 2 | 10 |
4 | 13 | 42.16 | 18 | 15.38 | 390 | 108 | 2.79 / 18.38 | 2 | 13 |
5 | 8 | -0.24 | 165 | 15.34 | 317 | 802 | 3.59 / 19.19 | 2 | 16 |
Average= | 3.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 27 | 15.29 | 457 | 189 | 0.19 / 12.33 | 2 | 3 |
2 | 3 | 1020.36 | 1 | 15.37 | 1789 | 27 | 0.22 / 12.36 | 2 | 7 |
3 | 7 | 1246.24 | 74 | 15.15 | 1967 | 2205 | 2.42 / 14.56 | 2 | 11 |
4 | 13 | 99.56 | 18 | 15.40 | 474 | 131 | 2.55 / 14.70 | 2 | 10 |
5 | 13 | 28.04 | 18 | 15.39 | 369 | 102 | 2.65 / 14.80 | 2 | 12 |
6 | 8 | -0.28 | 165 | 15.35 | 316 | 800 | 3.46 / 15.60 | 2 | 18 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 24 | 15.26 | 448 | 164 | 0.16 / 8.76 | 2 | 3 |
2 | 10 | 1010.40 | 2 | 15.30 | 1725 | 53 | 0.22 / 8.81 | 2 | 9 |
3 | 3 | 1020.28 | 1 | 15.36 | 1780 | 27 | 0.24 / 8.84 | 2 | 9 |
4 | 7 | 1321.68 | 74 | 15.12 | 2055 | 2299 | 2.54 / 11.14 | 2 | 10 |
5 | 13 | 91.12 | 18 | 15.39 | 452 | 125 | 2.67 / 11.26 | 2 | 8 |
6 | 13 | 28.80 | 18 | 15.38 | 359 | 99 | 2.77 / 11.36 | 2 | 13 |
7 | 8 | -0.24 | 165 | 15.34 | 309 | 782 | 3.55 / 12.14 | 2 | 16 |
Average= | 3.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 31 | 15.29 | 445 | 211 | 0.21 / 4.84 | 2 | 3 |
2 | 3 | 826.04 | -3 | 15.68 | 0 | 0 | 0.00 / 4.84 | 2 | 3 |
3 | 3 | 901.36 | -2 | 15.71 | 0 | 0 | 0.00 / 4.84 | 2 | 3 |
4 | 7 | 1523.72 | 74 | 15.05 | 2305 | 2567 | 2.78 / 7.41 | 2 | 7 |
5 | 13 | 272.24 | 18 | 15.34 | 715 | 197 | 2.98 / 7.61 | 2 | 9 |
6 | 13 | 94.00 | 18 | 15.35 | 452 | 125 | 3.10 / 7.73 | 2 | 10 |
7 | 13 | 30.40 | 18 | 15.34 | 354 | 98 | 3.20 / 7.83 | 2 | 9 |
8 | 8 | 0.12 | 165 | 15.31 | 301 | 760 | 3.96 / 8.59 | 2 | 19 |
Average= | 2.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 26 | 15.46 | 419 | 168 | 0.17 / 1.87 | 3 | 3 |
2 | 7 | 1008.48 | 74 | 15.23 | 1663 | 1874 | 2.04 / 3.74 | 2 | 10 |
3 | 13 | 53.28 | 18 | 15.41 | 399 | 111 | 2.15 / 3.85 | 2 | 10 |
4 | 8 | 0.16 | 165 | 15.36 | 309 | 783 | 2.94 / 4.63 | 2 | 15 |
Average= | 2.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 91.20 | 26 | 15.64 | 380 | 155 | 0.15 / 0.15 | 2 | 4 |
2 | 7 | 108.52 | 74 | 15.61 | 416 | 481 | 0.64 / 0.64 | 3 | 4 |
3 | 13 | 50.60 | 18 | 15.59 | 327 | 92 | 0.73 / 0.73 | 3 | 5 |
4 | 8 | 0.20 | 240 | 15.55 | 260 | 970 | 1.70 / 1.70 | 2 | 20 |
Average= | 1.70 (KJ/cycle) |