SIO Argo Site:
Pump Diagnostics Page   



Serial= 6105 WMO= 5906934

Return

←PreviousNext→

Cycle 72 GMT 17/11/2024 5:33: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.6 7 10 14.93 467 70 0.07 / 1312.79 2 16
2 6 6003.6 890 67 14.26 4506 4305 4.37 / 1317.09 2 52
3 3 5452.6 1071 14 14.46 4134 837 5.21 / 1317.93 2 53
4 7 4992.7 12183 80 14.48 3830 4437 9.65 / 1322.36 2 58
5 13 4160.8 12381 80 14.42 3275 3778 13.43 / 1326.14 2 63
6 13 2751.3 12675 80 14.59 2331 2721 16.15 / 1328.86 2 65
7 13 1856.5 12837 80 14.70 1732 2037 18.18 / 1330.90 2 61
8 13 777.8 13017 80 14.86 994 1182 19.37 / 1332.08 2 58
9 13 724.7 13024 80 14.82 949 1125 20.49 / 1333.21 2 63
10 14 0.9 13113 95 14.91 427 605 21.10 / 1333.81 4 116
11 14 0.9 13113 5 14.91 405 30 21.13 / 1333.84 50 119
Average= 18.27
(KJ/cycle)

Cycle 71 GMT 7/11/2024 5:54: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.1 7 10 14.93 463 69 0.07 / 1291.83 2 15
2 6 6007.2 856 65 14.27 4517 4190 4.26 / 1296.02 2 51
3 3 5459.7 1037 15 14.45 4145 898 5.16 / 1296.91 2 53
4 7 5032.4 12183 80 14.47 3854 4461 9.62 / 1301.37 2 57
5 13 4104.0 12399 80 14.43 3240 3740 13.36 / 1305.12 2 63
6 13 2886.2 12663 80 14.57 2433 2836 16.19 / 1307.95 2 65
7 13 1926.4 12843 80 14.69 1785 2098 18.29 / 1310.05 2 61
8 13 748.3 13043 80 14.87 973 1157 19.45 / 1311.21 2 57
9 13 421.5 13091 80 14.87 730 868 20.32 / 1312.07 2 55
10 14 0.3 13147 103 14.92 417 641 20.96 / 1312.72 2 133
Average= 18.23
(KJ/cycle)

Cycle 70 GMT 28/10/2024 6:15: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.4 7 10 14.91 451 67 0.07 / 1270.86 2 14
2 6 6006.8 864 67 14.27 4514 4316 4.38 / 1275.18 2 52
3 3 5422.5 1045 12 14.48 4085 710 5.09 / 1275.89 2 54
4 7 5003.1 12183 80 14.48 3838 4446 9.54 / 1280.33 2 57
5 13 3948.5 12441 80 14.45 3132 3621 13.16 / 1283.95 2 63
6 13 2782.5 12687 80 14.58 2356 2748 15.91 / 1286.70 2 64
7 13 1934.7 12843 80 14.68 1786 2097 18.00 / 1288.80 2 60
8 13 817.9 13029 80 14.86 1023 1216 19.22 / 1290.01 2 57
9 13 713.5 13043 80 14.82 945 1120 20.34 / 1291.14 2 63
10 14 0.7 13131 101 14.92 412 621 20.96 / 1291.76 2 117
Average= 18.19
(KJ/cycle)

Cycle 69 GMT 18/10/2024 6:45: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.5 7 10 14.90 460 69 0.07 / 1248.59 2 13
2 6 6005.9 875 67 14.26 4505 4304 4.37 / 1252.89 2 51
3 3 5440.1 1056 14 14.47 4130 837 5.21 / 1253.73 2 53
4 7 5004.6 12183 80 14.48 3843 4452 9.66 / 1258.18 2 58
5 13 4113.1 12399 80 14.43 3233 3732 13.39 / 1261.91 2 63
6 13 2781.2 12687 80 14.59 2350 2743 16.14 / 1264.65 2 63
7 13 1972.9 12831 80 14.68 1812 2128 18.26 / 1266.78 2 60
8 13 786.8 13029 80 14.87 997 1186 19.45 / 1267.97 2 57
9 13 745.0 13035 80 14.82 953 1130 20.58 / 1269.10 2 64
10 13 704.9 13039 80 14.77 922 1089 21.67 / 1270.19 2 66
11 14 0.2 13111 67 14.90 419 418 22.09 / 1270.61 2 123
12 14 0.4 13111 33 14.89 384 189 22.28 / 1270.79 61 249
Average= 18.15
(KJ/cycle)

Cycle 68 GMT 8/10/2024 7:25: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.0 7 10 14.90 454 68 0.07 / 1226.30 2 16
2 6 6006.6 859 67 14.27 4490 4293 4.36 / 1230.59 2 51
3 3 5445.8 1040 14 14.47 4120 835 5.20 / 1231.43 2 53
4 7 5009.5 12183 80 14.48 3844 4453 9.65 / 1235.88 2 57
5 13 4039.7 12423 80 14.44 3192 3687 13.34 / 1239.57 2 63
6 13 2738.1 12711 80 14.60 2328 2719 16.05 / 1242.29 2 64
7 13 1858.4 12873 80 14.70 1744 2051 18.11 / 1244.34 2 60
8 13 960.1 13017 80 14.83 1127 1337 19.44 / 1245.68 2 59
9 13 738.8 13047 80 14.82 966 1145 20.59 / 1246.82 2 64
10 13 700.0 13051 80 14.77 928 1097 21.68 / 1247.92 2 67
11 14 0.4 13122 65 14.89 417 404 22.09 / 1248.32 2 108
12 14 0.5 13123 35 14.88 377 196 22.28 / 1248.52 50 249
Average= 18.09
(KJ/cycle)

Cycle 67 GMT 28/ 9/2024 8:11: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.0 7 10 14.93 456 68 0.07 / 1204.15 2 18
2 6 6006.0 853 69 14.26 4496 4424 4.49 / 1208.58 2 51
3 3 5407.6 1034 12 14.48 4083 709 5.20 / 1209.29 2 52
4 7 4978.8 12183 80 14.48 3814 4418 9.62 / 1213.70 2 58
5 13 4047.2 12399 80 14.44 3196 3692 13.31 / 1217.40 2 62
6 13 2742.9 12681 80 14.60 2327 2718 16.03 / 1220.11 2 65
7 13 1834.1 12849 80 14.71 1711 2014 18.04 / 1222.13 2 61
8 13 882.8 13005 80 14.85 1063 1263 19.31 / 1223.39 2 59
9 13 750.7 13023 80 14.82 961 1139 20.45 / 1224.53 2 63
10 13 713.5 13027 80 14.77 931 1100 21.55 / 1225.63 2 68
11 14 0.7 13098 63 14.89 424 398 21.94 / 1226.03 2 106
12 14 1.0 13099 37 14.88 375 206 22.15 / 1226.23 63 249
Average= 18.03
(KJ/cycle)

Cycle 66 GMT 18/ 9/2024 9:25: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.4 7 10 14.94 457 68 0.07 / 1182.70 2 15
2 6 6008.2 826 66 14.27 4491 4230 4.30 / 1186.93 2 51
3 3 5481.8 1007 16 14.45 4140 957 5.26 / 1187.89 2 52
4 7 5036.0 12183 80 14.48 3834 4441 9.70 / 1192.33 2 56
5 13 4168.1 12381 80 14.43 3263 3767 13.46 / 1196.09 2 61
6 13 2926.3 12627 80 14.57 2441 2845 16.31 / 1198.94 2 66
7 13 1999.5 12795 80 14.68 1821 2139 18.45 / 1201.08 2 59
8 13 857.3 12987 80 14.86 1047 1245 19.69 / 1202.32 2 58
9 13 712.4 13007 80 14.83 946 1122 20.81 / 1203.44 2 64
10 14 0.5 13095 103 14.93 416 640 21.45 / 1204.08 2 107
Average= 17.97
(KJ/cycle)

Cycle 65 GMT 8/ 9/2024 11: 7: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.0 7 10 14.93 459 69 0.07 / 1162.01 2 14
2 6 6003.2 843 69 14.26 4482 4410 4.48 / 1166.42 2 51
3 3 5402.1 1024 11 14.49 4074 649 5.13 / 1167.07 2 53
4 7 4999.1 12183 80 14.49 3831 4441 9.57 / 1171.51 2 57
5 13 4007.6 12429 80 14.45 3160 3653 13.22 / 1175.16 2 62
6 13 2742.2 12705 80 14.60 2315 2704 15.93 / 1177.87 2 66
7 13 1995.7 12843 80 14.68 1815 2132 18.06 / 1180.00 2 61
8 13 756.8 13049 80 14.88 978 1164 19.22 / 1181.16 2 57
9 13 414.4 13097 80 14.88 723 861 20.08 / 1182.02 2 55
10 14 0.2 13152 99 14.93 407 602 20.68 / 1182.62 2 108
11 14 0.4 13152 1 14.92 415 6 20.69 / 1182.63 61 83
Average= 17.92
(KJ/cycle)

Cycle 64 GMT 29/ 8/2024 11:37: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.4 7 10 14.93 461 69 0.07 / 1140.68 2 14
2 6 6003.9 838 71 14.26 4491 4547 4.62 / 1145.23 2 52
3 3 5396.6 1019 11 14.49 4084 651 5.27 / 1145.88 2 54
4 7 5009.4 12183 80 14.49 3819 4427 9.69 / 1150.31 2 57
5 13 4064.7 12423 80 14.45 3189 3686 13.38 / 1153.99 2 63
6 13 2700.9 12723 80 14.61 2298 2686 16.07 / 1156.68 2 65
7 13 1995.9 12855 80 14.68 1820 2137 18.20 / 1158.82 2 61
8 13 998.5 13011 80 14.83 1154 1369 19.57 / 1160.19 2 59
9 13 722.2 13048 80 14.83 955 1133 20.71 / 1161.32 2 64
10 14 0.5 13137 99 14.93 415 613 21.32 / 1161.93 2 100
11 14 0.6 13137 1 14.92 418 6 21.33 / 1161.94 46 88
Average= 17.88
(KJ/cycle)

Cycle 63 GMT 19/ 8/2024 12:30: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.8 7 10 14.92 441 66 0.07 / 1119.22 2 13
2 6 6007.4 810 72 14.25 4504 4621 4.69 / 1123.84 2 50
3 3 5406.5 991 12 14.48 4092 711 5.40 / 1124.56 2 55
4 7 5032.0 12183 80 14.48 3860 4471 9.87 / 1129.03 2 58
5 13 3996.4 12441 80 14.45 3160 3653 13.52 / 1132.68 2 63
6 13 2783.5 12705 80 14.60 2357 2753 16.28 / 1135.43 2 63
7 13 1980.2 12855 80 14.68 1820 2137 18.41 / 1137.57 2 61
8 13 893.3 13035 80 14.86 1075 1278 19.69 / 1138.85 2 59
9 13 736.8 13055 80 14.83 960 1139 20.83 / 1139.99 2 64
10 14 0.3 13146 103 14.93 408 627 21.46 / 1140.61 2 130
Average= 17.82
(KJ/cycle)

Cycle 62 GMT 9/ 8/2024 13:39: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.8 7 10 14.93 457 68 0.07 / 1096.93 2 16
2 6 6007.7 821 67 14.27 4514 4316 4.38 / 1101.25 2 51
3 3 5475.0 1002 16 14.47 4139 958 5.34 / 1102.20 2 53
4 7 5090.7 12183 80 14.48 3891 4507 9.85 / 1106.71 2 57
5 13 4339.3 12351 80 14.41 3382 3899 13.75 / 1110.61 2 60
6 13 2823.8 12675 80 14.60 2385 2786 16.53 / 1113.40 2 64
7 13 1979.3 12837 80 14.69 1817 2135 18.67 / 1115.53 2 61
8 13 1030.0 12987 80 14.83 1170 1388 20.06 / 1116.92 2 60
9 13 745.1 13025 80 14.83 961 1140 21.20 / 1118.06 2 64
10 13 22.6 13111 80 14.92 432 516 21.71 / 1118.58 2 33
11 14 0.0 13120 45 14.92 419 281 21.99 / 1118.86 2 121
12 14 0.1 13121 55 14.90 367 301 22.30 / 1119.16 66 249
Average= 17.76
(KJ/cycle)

Cycle 61 GMT 30/ 7/2024 15: 5: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.0 7 10 14.93 450 67 0.07 / 1075.53 2 15
2 6 6006.9 854 66 14.27 4516 4253 4.32 / 1079.79 2 50
3 3 5457.8 1035 15 14.46 4127 895 5.22 / 1080.68 2 53
4 7 5024.8 12183 80 14.49 3837 4448 9.66 / 1085.13 2 57
5 13 4138.6 12387 80 14.44 3243 3746 13.41 / 1088.88 2 62
6 13 2771.2 12687 80 14.61 2340 2735 16.14 / 1091.61 2 65
7 13 1986.0 12837 80 14.69 1818 2137 18.28 / 1093.75 2 61
8 13 981.6 12999 80 14.84 1133 1345 19.63 / 1095.09 2 60
9 13 738.4 13031 80 14.83 964 1144 20.77 / 1096.24 2 64
10 14 0.5 13119 101 14.93 415 626 21.40 / 1096.86 2 105
Average= 17.69
(KJ/cycle)

Cycle 60 GMT 20/ 7/2024 15:57: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.1 7 15 14.94 455 102 0.10 / 1054.93 2 16
2 6 5704.7 783 75 14.28 4311 4617 4.72 / 1059.55 2 52
3 3 5162.6 964 9 14.52 3956 517 5.24 / 1060.07 2 54
4 7 4814.2 12183 80 14.52 3711 4311 9.55 / 1064.38 2 58
5 13 3905.4 12411 80 14.47 3094 3582 13.13 / 1067.96 2 62
6 13 2627.2 12681 80 14.63 2246 2629 15.76 / 1070.59 2 64
7 13 1796.9 12831 80 14.72 1685 1984 17.74 / 1072.57 2 62
8 13 756.4 12999 80 14.88 976 1162 18.90 / 1073.74 2 58
9 13 726.5 13003 80 14.83 937 1112 20.01 / 1074.85 3 62
10 14 0.8 13088 84 14.93 418 524 20.54 / 1075.37 2 118
11 14 0.9 13088 16 14.91 397 95 20.63 / 1075.47 51 249
Average= 17.63
(KJ/cycle)

Cycle 59 GMT 10/ 7/2024 18:28: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.3 7 12 14.95 445 80 0.08 / 1033.75 2 13
2 6 5708.0 757 75 14.29 4309 4618 4.70 / 1038.37 2 52
3 3 5233.9 938 13 14.49 3985 751 5.45 / 1039.12 2 54
4 7 4890.3 12183 80 14.51 3764 4369 9.82 / 1043.49 2 57
5 13 4019.7 12381 80 14.46 3178 3676 13.49 / 1047.17 2 63
6 13 2760.3 12645 80 14.61 2342 2737 16.23 / 1049.91 2 64
7 13 1860.9 12807 80 14.72 1733 2041 18.27 / 1051.95 2 62
8 13 749.1 12987 80 14.89 971 1157 19.43 / 1053.10 2 57
9 13 715.6 12991 80 14.84 940 1116 20.54 / 1054.22 2 63
10 14 0.6 13074 90 14.93 413 555 21.10 / 1054.77 2 132
11 14 0.9 13074 10 14.92 398 59 21.16 / 1054.83 67 237
Average= 17.58
(KJ/cycle)

Cycle 58 GMT 30/ 6/2024 21:37: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.4 7 14 14.95 449 94 0.09 / 1013.55 2 15
2 6 5707.4 802 75 14.29 4314 4624 4.72 / 1018.18 2 53
3 3 5181.8 983 10 14.52 3945 573 5.29 / 1018.75 2 53
4 7 4825.4 12183 80 14.52 3711 4311 9.60 / 1023.06 2 58
5 13 3824.9 12435 80 14.49 3042 3526 13.13 / 1026.59 2 62
6 13 2593.1 12711 80 14.64 2225 2606 15.73 / 1029.19 2 64
7 13 1742.5 12867 80 14.74 1650 1946 17.68 / 1031.14 2 62
8 13 738.5 13030 80 14.88 965 1149 18.83 / 1032.29 2 57
9 13 299.9 13090 80 14.90 646 770 19.60 / 1033.06 2 44
10 14 0.5 13129 84 14.94 413 518 20.12 / 1033.58 2 107
11 14 0.6 13129 16 14.93 412 98 20.21 / 1033.67 45 249
Average= 17.52
(KJ/cycle)

Cycle 57 GMT 20/ 6/2024 23:12: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.2 7 16 14.95 441 105 0.11 / 993.17 2 12
2 6 5707.6 770 74 14.30 4309 4560 4.67 / 997.73 2 53
3 3 5204.2 951 11 14.51 3961 632 5.30 / 998.36 2 54
4 7 4851.7 12183 80 14.52 3717 4318 9.62 / 1002.68 2 58
5 13 4075.2 12363 80 14.46 3195 3696 13.31 / 1006.38 2 62
6 13 2649.8 12663 80 14.64 2259 2646 15.96 / 1009.02 2 63
7 13 1766.0 12825 80 14.74 1666 1965 17.92 / 1010.99 2 63
8 13 740.7 12995 80 14.89 971 1157 19.08 / 1012.15 2 57
9 13 230.9 13067 80 14.92 591 705 19.78 / 1012.85 2 41
10 14 0.3 13101 88 14.94 408 536 20.32 / 1013.39 2 125
11 14 0.4 13101 12 14.93 404 72 20.39 / 1013.46 56 249
Average= 17.47
(KJ/cycle)

Cycle 56 GMT 11/ 6/2024 1:48: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.9 7 12 14.94 448 80 0.08 / 972.29 2 13
2 6 5705.5 753 75 14.29 4307 4616 4.70 / 976.91 2 51
3 3 5245.1 934 14 14.49 3994 810 5.51 / 977.72 2 55
4 7 4911.1 12183 80 14.51 3769 4375 9.88 / 982.09 2 57
5 13 3951.4 12429 80 14.48 3133 3629 13.51 / 985.72 2 62
6 13 2612.5 12723 80 14.65 2242 2628 16.14 / 988.35 2 65
7 13 1986.2 12837 80 14.69 1816 2134 18.27 / 990.49 2 63
8 13 743.3 13037 80 14.89 973 1159 19.43 / 991.65 2 57
9 13 357.3 13091 80 14.90 685 817 20.25 / 992.46 2 49
10 14 0.2 13140 84 14.95 405 509 20.76 / 992.97 2 114
11 14 0.3 13140 16 14.93 405 97 20.85 / 993.07 49 249
Average= 17.42
(KJ/cycle)

Cycle 55 GMT 1/ 6/2024 4: 1: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.6 7 11 14.95 457 75 0.08 / 951.16 2 15
2 6 5709.0 773 75 14.29 4306 4615 4.69 / 955.77 2 52
3 3 5193.0 954 11 14.50 3956 631 5.32 / 956.40 2 55
4 7 4893.3 12183 80 14.52 3755 4362 9.68 / 960.76 2 57
5 13 3975.5 12399 80 14.48 3141 3639 13.32 / 964.40 2 63
6 13 2773.3 12651 80 14.62 2339 2736 16.06 / 967.14 2 63
7 13 1878.7 12819 80 14.72 1741 2050 18.11 / 969.19 2 61
8 13 890.2 12975 80 14.86 1072 1274 19.38 / 970.46 2 59
9 13 734.6 12995 80 14.84 956 1135 20.52 / 971.60 2 65
10 14 0.5 13083 84 14.94 415 521 21.04 / 972.12 2 114
11 14 0.5 13083 16 14.92 400 95 21.13 / 972.21 47 249
Average= 17.36
(KJ/cycle)

Cycle 54 GMT 22/ 5/2024 6:53: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 7 12 14.94 462 83 0.08 / 930.70 2 15
2 6 5708.6 783 74 14.30 4318 4569 4.65 / 935.27 2 52
3 3 5196.6 964 11 14.50 3969 633 5.29 / 935.90 2 54
4 7 4861.5 12183 80 14.52 3729 4332 9.62 / 940.23 2 58
5 13 3845.3 12435 80 14.50 3052 3540 13.16 / 943.77 2 63
6 13 2613.3 12699 80 14.64 2242 2626 15.78 / 946.40 2 65
7 13 1972.3 12813 80 14.69 1810 2127 17.91 / 948.52 2 62
8 13 745.9 13007 80 14.89 978 1165 19.08 / 949.69 2 56
9 13 310.3 13067 80 14.91 653 779 19.85 / 950.47 2 49
10 14 0.4 13110 80 14.94 414 495 20.35 / 950.96 2 127
11 14 0.5 13111 20 14.93 391 117 20.47 / 951.08 59 249
Average= 17.29
(KJ/cycle)

Cycle 53 GMT 12/ 5/2024 9: 6: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.5 7 13 14.92 456 88 0.09 / 910.06 2 16
2 6 5708.1 786 75 14.29 4320 4630 4.72 / 914.69 2 52
3 3 5176.9 967 10 14.51 3975 577 5.30 / 915.26 2 54
4 7 4844.8 12183 80 14.52 3739 4343 9.64 / 919.61 2 58
5 13 3811.8 12429 80 14.50 3037 3523 13.16 / 923.13 2 62
6 13 2523.0 12717 80 14.66 2189 2567 15.73 / 925.70 2 64
7 13 1872.5 12837 80 14.72 1734 2042 17.77 / 927.74 2 62
8 13 750.9 13017 80 14.90 968 1154 18.92 / 928.89 2 58
9 13 720.9 13021 80 14.84 931 1105 20.03 / 930.00 3 62
10 14 0.4 13107 84 14.94 415 521 20.55 / 930.52 2 129
11 14 0.9 13108 16 14.93 401 96 20.65 / 930.61 61 249
Average= 17.23
(KJ/cycle)

Cycle 52 GMT 2/ 5/2024 11:15: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.3 7 13 14.95 455 88 0.09 / 887.93 2 14
2 6 5709.1 768 74 14.30 4316 4567 4.66 / 892.49 2 52
3 3 5203.6 949 11 14.51 3971 634 5.29 / 893.13 2 54
4 7 4893.3 12183 80 14.52 3764 4372 9.66 / 897.50 2 59
5 13 3912.8 12411 80 14.49 3101 3595 13.26 / 901.09 2 63
6 13 2746.7 12657 80 14.62 2333 2729 15.99 / 903.82 2 64
7 13 1989.2 12789 80 14.69 1828 2148 18.13 / 905.97 2 63
8 13 778.4 12987 80 14.90 996 1187 19.32 / 907.16 2 59
9 13 738.8 12993 80 14.85 954 1133 20.45 / 908.29 2 64
10 13 699.9 12997 80 14.80 915 1083 21.54 / 909.37 2 66
11 14 1.2 13067 63 14.91 416 391 21.93 / 909.76 2 126
12 14 1.4 13068 37 14.90 370 204 22.13 / 909.97 66 249
Average= 17.17
(KJ/cycle)

Cycle 51 GMT 22/ 4/2024 14:26: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.0 7 13 14.95 454 88 0.09 / 867.41 2 15
2 6 5704.5 770 74 14.30 4306 4557 4.64 / 871.97 2 53
3 3 5187.1 951 10 14.52 3981 578 5.22 / 872.54 2 54
4 7 4890.6 12183 80 14.52 3773 4383 9.61 / 876.93 2 57
5 13 4044.0 12375 80 14.47 3190 3693 13.30 / 880.62 2 62
6 13 2627.9 12687 80 14.65 2257 2645 15.94 / 883.26 2 63
7 13 1864.7 12831 80 14.73 1733 2042 17.99 / 885.31 2 63
8 13 755.8 13013 80 14.90 982 1171 19.16 / 886.48 2 57
9 13 281.4 13079 80 14.92 629 751 19.91 / 887.23 2 48
10 14 0.6 13118 86 14.95 408 525 20.43 / 887.75 2 101
11 14 0.8 13118 14 14.94 404 85 20.52 / 887.84 45 249
Average= 17.07
(KJ/cycle)

Cycle 50 GMT 12/ 4/2024 16:45: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 7 15 14.95 455 102 0.10 / 846.70 2 12
2 6 5707.0 784 74 14.30 4318 4569 4.67 / 851.27 2 53
3 3 5161.3 965 9 14.52 3947 516 5.19 / 851.78 2 53
4 7 4864.2 12183 80 14.53 3741 4349 9.54 / 856.13 2 57
5 13 3846.0 12423 80 14.50 3063 3553 13.09 / 859.68 2 64
6 13 2527.3 12729 80 14.67 2191 2571 15.66 / 862.26 2 64
7 13 1927.0 12843 80 14.71 1788 2104 17.76 / 864.36 2 63
8 13 825.3 13017 80 14.89 1030 1227 18.99 / 865.59 2 59
9 13 719.6 13031 80 14.85 944 1121 20.11 / 866.71 2 64
10 14 0.4 13118 84 14.95 410 515 20.63 / 867.22 2 110
11 14 0.7 13118 16 14.93 407 97 20.72 / 867.32 51 249
Average= 17.01
(KJ/cycle)

Cycle 49 GMT 2/ 4/2024 18:48: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.5 7 15 14.95 456 102 0.10 / 825.69 2 12
2 6 5707.6 779 75 14.29 4310 4619 4.72 / 830.31 2 52
3 3 5166.5 960 9 14.54 3943 516 5.24 / 830.83 2 54
4 7 4878.2 12183 80 14.53 3770 4382 9.62 / 835.21 2 57
5 13 3982.3 12387 80 14.48 3157 3657 13.28 / 838.87 2 62
6 13 2693.6 12657 80 14.64 2304 2698 15.98 / 841.57 2 65
7 13 1887.6 12807 80 14.73 1760 2074 18.05 / 843.64 2 64
8 13 836.7 12975 80 14.89 1028 1225 19.27 / 844.87 2 59
9 13 726.7 12989 80 14.85 944 1121 20.40 / 845.99 2 64
10 14 0.8 13077 84 14.95 407 511 20.91 / 846.50 3 109
11 14 1.1 13077 16 14.94 407 97 21.00 / 846.60 40 249
Average= 16.93
(KJ/cycle)

Cycle 48 GMT 23/ 3/2024 21:40: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.9 7 16 14.95 452 108 0.11 / 805.31 2 16
2 6 5709.5 774 74 14.30 4311 4562 4.67 / 809.88 2 54
3 3 5194.0 955 11 14.52 3952 631 5.30 / 810.51 2 54
4 7 4867.7 12183 80 14.53 3753 4362 9.66 / 814.87 2 58
5 13 3869.5 12423 80 14.50 3087 3581 13.24 / 818.45 2 63
6 13 2622.2 12687 80 14.65 2241 2626 15.87 / 821.08 2 63
7 13 1932.5 12813 80 14.71 1777 2091 17.96 / 823.17 2 63
8 13 751.3 13001 80 14.90 967 1153 19.11 / 824.32 2 58
9 13 183.4 13079 80 14.94 554 662 19.78 / 824.98 2 42
10 14 0.7 13109 82 14.95 411 504 20.28 / 825.49 2 122
11 14 0.7 13110 18 14.94 394 106 20.39 / 825.59 55 249
Average= 16.85
(KJ/cycle)

Cycle 47 GMT 14/ 3/2024 0: 2: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.2 7 14 14.95 454 95 0.10 / 784.05 2 10
2 6 5708.9 761 75 14.29 4314 4624 4.72 / 788.68 2 53
3 3 5191.2 942 11 14.51 4005 639 5.36 / 789.32 2 55
4 7 4904.1 12183 80 14.53 3782 4396 9.75 / 793.71 2 59
5 13 3930.6 12417 80 14.49 3131 3629 13.38 / 797.34 2 62
6 13 2752.8 12663 80 14.63 2335 2733 16.12 / 800.07 2 64
7 13 1977.4 12801 80 14.71 1805 2124 18.24 / 802.20 2 64
8 13 911.3 12969 80 14.88 1080 1286 19.53 / 803.48 2 60
9 13 709.8 12995 80 14.86 929 1104 20.63 / 804.59 2 63
10 14 0.3 13082 90 14.95 414 557 21.19 / 805.15 2 102
11 14 0.4 13083 10 14.94 402 60 21.25 / 805.21 52 198
Average= 16.78
(KJ/cycle)

Cycle 46 GMT 4/ 3/2024 3: 6: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.0 7 16 14.95 457 109 0.11 / 763.00 2 13
2 6 5707.7 786 74 14.30 4322 4574 4.68 / 767.58 2 52
3 3 5163.4 967 9 14.53 3982 521 5.20 / 768.10 2 54
4 7 4872.3 12183 80 14.53 3769 4381 9.58 / 772.48 2 58
5 13 3929.0 12411 80 14.50 3121 3620 13.21 / 776.10 2 63
6 13 2841.4 12633 80 14.61 2397 2802 16.01 / 778.90 2 62
7 13 1957.3 12783 80 14.71 1796 2114 18.12 / 781.01 2 65
8 13 796.3 12969 80 14.90 1002 1194 19.31 / 782.21 2 58
9 13 734.5 12977 80 14.85 952 1131 20.45 / 783.34 2 64
10 14 1.2 13063 88 14.95 415 546 20.99 / 783.88 2 122
11 14 1.5 13064 12 14.94 410 74 21.07 / 783.96 54 249
Average= 16.68
(KJ/cycle)

Cycle 45 GMT 23/ 2/2024 6: 3: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.4 7 15 14.95 464 104 0.10 / 742.35 2 15
2 6 5704.8 774 74 14.30 4318 4569 4.67 / 746.92 2 52
3 3 5210.2 955 12 14.51 3976 692 5.37 / 747.61 2 53
4 7 4884.7 12183 80 14.54 3775 4391 9.76 / 752.00 2 57
5 13 3854.4 12429 80 14.51 3069 3562 13.32 / 755.57 2 61
6 13 2597.3 12723 80 14.67 2236 2624 15.94 / 758.19 2 66
7 13 1952.2 12843 80 14.72 1793 2111 18.05 / 760.30 2 70
8 13 738.2 13037 80 14.91 962 1147 19.20 / 761.45 2 63
9 13 223.9 13109 80 14.94 592 708 19.91 / 762.16 2 44
10 14 0.6 13143 119 14.95 414 737 20.65 / 762.89 2 125
Average= 16.58
(KJ/cycle)

Cycle 44 GMT 13/ 2/2024 7:52: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.4 7 15 14.93 463 104 0.10 / 721.24 2 13
2 6 5706.1 772 75 14.29 4331 4642 4.75 / 725.88 2 52
3 3 5139.7 953 8 14.53 3949 459 5.20 / 726.34 2 54
4 7 4907.0 12183 80 14.54 3791 4410 9.61 / 730.75 2 57
5 13 4005.9 12393 80 14.48 3181 3685 13.30 / 734.43 2 62
6 13 2606.1 12693 80 14.67 2244 2634 15.93 / 737.07 2 63
7 13 1970.4 12807 80 14.71 1811 2131 18.06 / 739.20 2 66
8 13 851.1 12981 80 14.89 1053 1254 19.32 / 740.45 2 63
9 13 744.6 12995 80 14.85 974 1157 20.48 / 741.61 2 66
10 14 0.5 13085 90 14.95 426 573 21.05 / 742.18 2 122
11 14 0.7 13085 10 14.94 423 63 21.11 / 742.25 57 236
Average= 16.49
(KJ/cycle)

Cycle 43 GMT 3/ 2/2024 10:43: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.4 7 14 14.96 449 94 0.09 / 699.08 2 14
2 6 5704.7 768 75 14.30 4335 4649 4.74 / 703.73 2 52
3 3 5208.0 949 12 14.51 3959 689 5.43 / 704.42 2 54
4 7 4886.3 12183 80 14.54 3771 4386 9.82 / 708.81 2 58
5 13 3857.2 12429 80 14.51 3090 3587 13.41 / 712.40 2 62
6 13 2591.4 12711 80 14.67 2250 2641 16.05 / 715.04 2 64
7 13 1866.7 12843 80 14.74 1745 2058 18.10 / 717.09 2 67
8 13 779.6 13017 80 14.91 999 1192 19.30 / 718.29 2 60
9 13 739.4 13023 80 14.86 960 1141 20.44 / 719.43 3 66
10 13 699.5 13027 80 14.81 930 1102 21.54 / 720.53 2 118
11 14 1.3 13099 60 14.93 426 382 21.92 / 720.91 2 113
12 14 1.6 13100 40 14.91 375 224 22.14 / 721.13 55 249
Average= 16.39
(KJ/cycle)

Cycle 42 GMT 24/ 1/2024 13:19: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.0 7 15 14.96 459 103 0.10 / 678.31 2 16
2 6 5683.4 743 74 14.31 4313 4567 4.67 / 682.88 2 52
3 3 5173.1 924 10 14.54 3974 578 5.25 / 683.46 2 54
4 7 4877.5 12183 80 14.55 3761 4378 9.63 / 687.83 2 57
5 13 4086.5 12375 80 14.48 3216 3725 13.35 / 691.56 2 62
6 13 2707.0 12651 80 14.65 2319 2718 16.07 / 694.28 2 65
7 13 1908.0 12795 80 14.73 1779 2096 18.17 / 696.37 2 70
8 13 738.8 12982 80 14.91 972 1159 19.32 / 697.53 2 64
9 13 175.8 13060 80 14.95 557 666 19.99 / 698.20 2 42
10 14 0.6 13087 129 14.95 410 791 20.78 / 698.99 2 117
Average= 16.26
(KJ/cycle)

Cycle 41 GMT 14/ 1/2024 16:34: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.2 7 16 14.93 454 108 0.11 / 657.63 2 12
2 6 5704.8 766 75 14.30 4336 4650 4.76 / 662.28 2 50
3 3 5210.5 947 12 14.51 3962 690 5.45 / 662.97 2 54
4 7 4812.2 12183 80 14.56 3736 4352 9.80 / 667.33 2 58
5 13 3861.4 12405 80 14.51 3086 3582 13.38 / 670.91 2 62
6 13 2540.9 12693 80 14.68 2209 2594 15.98 / 673.50 2 66
7 13 1937.2 12801 80 14.72 1796 2115 18.09 / 675.62 2 66
8 13 739.7 12983 80 14.91 971 1158 19.25 / 676.78 2 61
9 13 297.5 13043 80 14.93 647 773 20.02 / 677.55 2 49
10 14 0.4 13083 108 14.96 409 661 20.68 / 678.21 2 131
Average= 16.15
(KJ/cycle)

Cycle 40 GMT 4/ 1/2024 19:31: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.6 7 12 14.97 449 81 0.08 / 635.22 2 13
2 6 5708.9 758 75 14.30 4331 4645 4.73 / 639.87 2 51
3 3 5209.1 939 12 14.52 4010 699 5.42 / 640.57 2 54
4 7 4925.3 12183 80 14.54 3814 4436 9.86 / 645.00 2 57
5 13 4035.5 12381 80 14.48 3204 3712 13.57 / 648.71 2 60
6 13 2684.4 12675 80 14.66 2311 2710 16.28 / 651.42 2 65
7 13 1859.7 12831 80 14.75 1743 2057 18.34 / 653.48 2 67
8 13 787.4 13011 80 14.92 1005 1200 19.54 / 654.68 2 59
9 13 746.7 13017 80 14.87 963 1146 20.68 / 655.83 3 64
10 13 705.0 13021 80 14.82 924 1095 21.78 / 656.92 2 97
11 14 0.9 13091 58 14.94 423 367 22.15 / 657.29 2 125
12 14 1.1 13092 42 14.92 377 236 22.38 / 657.52 60 249
Average= 16.04
(KJ/cycle)

Cycle 39 GMT 25/12/2023 22:29: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.1 7 12 14.96 455 82 0.08 / 614.99 2 15
2 6 4986.6 613 86 14.37 3856 4765 4.85 / 619.76 2 52
3 7 4864.4 12002 80 14.57 3752 4373 9.22 / 624.13 2 58
4 13 4106.2 12170 80 14.48 3252 3767 12.99 / 627.90 2 61
5 13 2678.6 12464 80 14.67 2303 2703 15.69 / 630.60 2 65
6 13 1769.1 12632 80 14.78 1683 1990 17.68 / 632.59 2 67
7 13 736.2 12803 80 14.93 965 1153 18.83 / 633.74 2 60
8 13 218.4 12875 80 14.96 588 704 19.54 / 634.45 2 47
9 14 1.0 12906 114 14.96 408 696 20.23 / 635.14 2 115
Average= 15.88
(KJ/cycle)

Cycle 38 GMT 16/12/2023 3:51: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.3 7 22 14.96 464 153 0.15 / 595.00 2 17
2 6 5505.7 768 68 14.35 4193 4092 4.24 / 599.09 2 53
3 3 5066.3 949 9 14.56 3889 510 4.75 / 599.60 2 54
4 7 4813.9 12183 80 14.57 3720 4336 9.09 / 603.93 2 59
5 13 3931.0 12381 80 14.52 3139 3646 12.74 / 607.58 2 62
6 13 2645.5 12651 80 14.68 2264 2659 15.39 / 610.24 2 65
7 13 1894.7 12789 80 14.75 1759 2076 17.47 / 612.31 2 67
8 13 748.1 12971 80 14.92 972 1160 18.63 / 613.47 2 60
9 13 265.3 13037 80 14.94 626 748 19.38 / 614.22 2 51
10 14 0.8 13075 110 14.96 418 688 20.07 / 614.91 2 121
Average= 15.77
(KJ/cycle)

Cycle 37 GMT 6/12/2023 6:53: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.3 7 20 14.96 456 136 0.14 / 574.06 2 18
2 6 5507.7 768 68 14.35 4193 4092 4.23 / 578.16 2 53
3 3 5062.9 949 9 14.56 3902 511 4.74 / 578.67 2 54
4 7 4841.8 12183 80 14.57 3740 4359 9.10 / 583.03 2 59
5 13 4482.7 12261 80 14.43 3495 4035 13.13 / 587.06 2 61
6 13 2615.2 12627 80 14.70 2257 2654 15.79 / 589.72 2 65
7 13 1825.8 12771 80 14.77 1720 2032 17.82 / 591.75 2 70
8 13 755.1 12945 80 14.94 985 1177 19.00 / 592.92 2 64
9 13 727.1 12949 80 14.88 950 1131 20.13 / 594.06 3 63
10 14 0.7 13034 125 14.96 421 787 20.92 / 594.84 2 124
Average= 15.65
(KJ/cycle)

Cycle 36 GMT 26/11/2023 10:37: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.2 7 23 14.96 472 162 0.16 / 554.46 2 21
2 6 5364.9 727 68 14.36 4119 4022 4.18 / 558.48 2 52
3 7 4893.2 12002 80 14.57 3765 4388 8.57 / 562.87 2 57
4 13 3990.9 12212 80 14.52 3173 3686 12.26 / 566.56 2 60
5 13 2586.2 12512 80 14.70 2236 2630 14.89 / 569.19 2 66
6 13 1978.8 12626 80 14.74 1815 2140 17.03 / 571.33 2 69
7 13 742.3 12821 80 14.94 971 1161 18.19 / 572.49 2 65
8 13 169.6 12899 80 14.97 553 662 18.85 / 573.15 2 46
9 14 0.2 12925 127 14.97 409 778 19.63 / 573.93 2 123
Average= 15.51
(KJ/cycle)

Cycle 35 GMT 16/11/2023 13:50: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.6 9 22 14.96 482 159 0.16 / 534.18 2 20
2 6 5508.0 755 69 14.35 4205 4164 4.32 / 538.34 2 51
3 3 5044.9 936 8 14.56 3906 455 4.78 / 538.80 2 54
4 7 4841.3 12183 80 14.57 3757 4379 9.16 / 543.18 2 58
5 13 3790.2 12447 80 14.55 3039 3537 12.69 / 546.72 2 60
6 13 2502.3 12735 80 14.72 2179 2566 15.26 / 549.28 2 64
7 13 1920.0 12837 80 14.75 1775 2094 17.35 / 551.38 2 68
8 13 750.9 13023 80 14.94 975 1165 18.52 / 552.54 2 64
9 13 719.6 13027 80 14.88 941 1120 19.64 / 553.66 3 62
10 14 0.6 13109 99 14.96 426 631 20.27 / 554.29 2 107
11 14 0.7 13109 1 14.95 414 6 20.28 / 554.30 45 90
Average= 15.40
(KJ/cycle)

Cycle 34 GMT 6/11/2023 16:30: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.5 9 23 14.96 486 167 0.17 / 513.82 2 21
2 6 5372.2 726 68 14.36 4120 4023 4.19 / 517.84 2 52
3 3 4955.8 907 3 14.64 3950 173 4.36 / 518.02 2 53
4 7 4893.4 12002 80 14.57 3791 4419 8.78 / 522.44 2 57
5 13 3919.9 12230 80 14.54 3131 3642 12.42 / 526.08 2 62
6 13 2523.7 12530 80 14.72 2193 2582 15.01 / 528.66 2 64
7 13 1997.0 12626 80 14.74 1828 2156 17.16 / 530.82 2 68
8 13 852.3 12806 80 14.92 1049 1252 18.41 / 532.07 2 66
9 13 743.0 12821 80 14.89 965 1150 19.56 / 533.22 2 66
10 14 0.4 12908 127 14.96 423 804 20.37 / 534.02 2 104
Average= 15.26
(KJ/cycle)

Cycle 33 GMT 27/10/2023 20: 1: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.2 7 22 14.98 456 150 0.15 / 493.29 2 20
2 6 5280.8 693 68 14.38 4059 3969 4.12 / 497.26 2 52
3 3 4960.9 874 3 14.64 3922 172 4.29 / 497.43 2 52
4 7 4929.5 12002 80 14.56 3830 4461 8.75 / 501.90 2 57
5 13 4006.7 12212 80 14.53 3206 3727 12.48 / 505.62 2 60
6 13 2671.6 12500 80 14.69 2308 2712 15.19 / 508.33 2 64
7 13 1985.6 12626 80 14.75 1827 2156 17.35 / 510.49 2 67
8 13 809.1 12812 80 14.93 1017 1215 18.56 / 511.71 2 65
9 13 744.1 12821 80 14.89 967 1152 19.71 / 512.86 2 66
10 14 0.6 12909 127 14.97 419 797 20.51 / 513.65 2 110
Average= 15.11
(KJ/cycle)

Cycle 32 GMT 18/10/2023 0: 3: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.3 9 19 14.98 477 136 0.14 / 473.24 2 22
2 6 5487.1 732 69 14.36 4202 4164 4.30 / 477.40 2 53
3 3 5061.9 913 9 14.57 3938 516 4.82 / 477.92 2 53
4 7 4877.3 12183 80 14.56 3801 4427 9.24 / 482.35 2 57
5 13 3983.3 12393 80 14.54 3191 3712 12.95 / 486.06 2 63
6 13 2662.4 12675 80 14.70 2289 2692 15.65 / 488.75 2 64
7 13 1829.0 12831 80 14.79 1725 2041 17.69 / 490.79 2 67
8 13 739.6 13006 80 14.95 968 1158 18.85 / 491.95 2 64
9 14 0.6 13119 193 14.99 413 1195 20.04 / 493.14 2 121
Average= 14.94
(KJ/cycle)

Cycle 31 GMT 8/10/2023 2:56: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.2 9 43 14.96 474 305 0.30 / 455.59 2 23
2 6 5010.3 698 62 14.43 3884 3475 3.78 / 459.06 2 53
3 3 4609.9 878 6 14.64 3617 318 4.10 / 459.38 2 55
4 7 4477.6 12002 80 14.62 3525 4123 8.22 / 463.50 2 60
5 13 3401.9 12266 80 14.63 2800 3277 11.50 / 466.78 2 63
6 13 2103.5 12560 80 14.79 1911 2261 13.76 / 469.04 2 64
7 13 1556.4 12656 80 14.83 1537 1823 15.58 / 470.86 2 70
8 13 740.8 12779 80 14.94 966 1155 16.74 / 472.02 2 66
9 14 -0.3 12882 174 14.99 416 1085 17.82 / 473.10 2 123
Average= 14.78
(KJ/cycle)

Cycle 30 GMT 28/ 9/2023 7:25: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.9 9 43 14.97 475 306 0.31 / 436.99 2 24
2 6 5007.6 718 62 14.44 3872 3467 3.77 / 440.45 2 53
3 3 4557.7 898 3 14.69 3697 163 3.94 / 440.62 2 56
4 7 4496.4 12002 80 14.63 3532 4134 8.07 / 444.75 2 58
5 13 3513.4 12236 80 14.62 2862 3347 11.42 / 448.10 2 62
6 13 2322.9 12488 80 14.76 2055 2427 13.84 / 450.52 2 63
7 13 1621.2 12614 80 14.82 1575 1867 15.71 / 452.39 2 70
8 13 748.4 12746 80 14.95 966 1155 16.87 / 453.55 2 65
9 13 711.6 12750 80 14.89 932 1110 17.98 / 454.66 3 58
10 14 0.2 12827 67 14.98 433 435 18.41 / 455.09 2 112
11 14 0.4 12828 33 14.97 385 190 18.60 / 455.28 48 249
Average= 14.69
(KJ/cycle)

Cycle 29 GMT 18/ 9/2023 12:26: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.1 9 42 14.98 477 300 0.30 / 418.37 2 24
2 6 5010.4 685 62 14.44 3877 3471 3.77 / 421.84 2 53
3 3 4652.0 866 8 14.62 3638 426 4.20 / 422.26 2 54
4 7 4451.9 12002 80 14.63 3500 4096 8.29 / 426.36 2 58
5 13 3555.6 12212 80 14.62 2899 3391 11.68 / 429.75 2 62
6 13 2157.3 12518 80 14.80 1949 2308 13.99 / 432.06 2 64
7 13 1462.6 12644 80 14.86 1466 1743 15.73 / 433.80 2 70
8 13 743.5 12752 80 14.95 964 1153 16.89 / 434.95 2 66
9 13 707.1 12756 80 14.90 928 1106 17.99 / 436.06 3 58
10 14 0.5 12833 65 14.99 430 419 18.41 / 436.48 2 112
11 14 0.6 12833 35 14.98 383 201 18.61 / 436.68 48 249
Average= 14.56
(KJ/cycle)

Cycle 28 GMT 8/ 9/2023 17:54: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 50.3 7 39 14.99 457 267 0.27 / 400.23 2 22
2 6 5008.7 684 61 14.44 3887 3424 3.69 / 403.65 2 53
3 3 4598.8 865 5 14.67 3588 263 3.95 / 403.92 2 54
4 7 4548.6 12002 80 14.63 3561 4168 8.12 / 408.08 2 58
5 13 3581.6 12254 80 14.63 2914 3411 11.53 / 411.49 2 61
6 13 2236.6 12554 80 14.79 2012 2381 13.91 / 413.87 2 65
7 13 1693.1 12656 80 14.82 1629 1931 15.84 / 415.81 2 68
8 13 745.3 12797 80 14.95 977 1168 17.01 / 416.97 2 66
9 14 0.5 12900 174 15.00 419 1094 18.11 / 418.07 2 106
Average= 14.42
(KJ/cycle)

Cycle 27 GMT 29/ 8/2023 22:15: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 70.6 9 37 14.98 476 264 0.26 / 382.29 2 22
2 6 5009.2 683 62 14.45 3874 3471 3.73 / 385.76 2 52
3 3 4600.3 864 5 14.68 3645 268 4.00 / 386.03 2 55
4 7 4514.8 12002 80 14.63 3535 4137 8.14 / 390.17 2 57
5 13 3478.7 12248 80 14.65 2847 3337 11.48 / 393.51 2 62
6 13 2293.2 12512 80 14.78 2029 2399 13.88 / 395.90 2 64
7 13 1550.1 12650 80 14.86 1526 1814 15.69 / 397.72 2 70
8 13 749.0 12773 80 14.96 970 1161 16.85 / 398.88 2 66
9 14 0.3 12873 174 15.01 414 1081 17.93 / 399.96 2 108
Average= 14.28
(KJ/cycle)

Cycle 26 GMT 20/ 8/2023 3: 6: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.8 9 28 15.01 472 198 0.20 / 362.85 2 21
2 6 5008.2 668 61 14.46 3884 3426 3.62 / 366.28 2 51
3 3 4747.2 849 14 14.60 3708 758 4.38 / 367.04 2 54
4 3 4555.8 1030 3 14.76 3660 162 4.54 / 367.20 2 55
5 7 4539.7 12002 80 14.63 3550 4155 8.70 / 371.36 2 58
6 13 3619.7 12218 80 14.63 2932 3432 12.13 / 374.79 2 63
7 13 2272.1 12506 80 14.79 2017 2387 14.52 / 377.17 2 65
8 13 1751.1 12596 80 14.82 1654 1961 16.48 / 379.13 2 67
9 13 744.9 12746 80 14.97 966 1157 17.64 / 380.29 2 65
10 13 712.4 12750 80 14.92 930 1110 18.75 / 381.40 3 59
11 14 0.5 12828 69 15.00 430 445 19.19 / 381.85 2 130
12 14 0.6 12828 31 14.99 394 183 19.37 / 382.03 50 249
Average= 14.15
(KJ/cycle)

Cycle 25 GMT 10/ 8/2023 8:57: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.8 8 67 15.02 451 454 0.45 / 347.34 2 21
2 6 4109.1 551 69 14.57 3255 3272 3.73 / 350.61 2 54
3 3 3784.0 732 4 14.76 3060 181 3.91 / 350.79 2 57
4 7 3741.4 12002 80 14.75 3014 3557 7.46 / 354.35 2 64
5 13 2875.8 12206 80 14.75 2430 2867 10.33 / 357.21 2 64
6 13 1914.0 12380 80 14.84 1770 2101 12.43 / 359.32 2 65
7 13 1030.1 12524 80 14.95 1162 1390 13.82 / 360.71 2 68
8 13 724.5 12563 80 14.95 948 1134 14.96 / 361.84 2 67
9 14 0.3 12648 131 15.02 415 817 15.77 / 362.66 2 129
Average= 13.95
(KJ/cycle)

Cycle 24 GMT 31/ 7/2023 19:44: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.7 8 69 15.02 456 473 0.47 / 332.07 2 22
2 6 4110.4 586 71 14.58 3250 3364 3.84 / 335.43 2 55
3 7 3644.4 12002 80 14.77 2943 3477 7.31 / 338.91 2 62
4 13 2861.7 12188 80 14.75 2412 2846 10.16 / 341.75 2 61
5 13 1997.7 12350 80 14.84 1816 2156 12.32 / 343.91 2 66
6 13 836.0 12548 80 15.00 1018 1222 13.54 / 345.13 2 64
7 13 729.1 12563 80 14.97 937 1122 14.66 / 346.25 2 64
8 14 0.5 12649 95 15.04 419 599 15.26 / 346.85 2 131
9 14 0.6 12649 5 15.03 413 31 15.29 / 346.88 54 132
Average= 13.88
(KJ/cycle)

Cycle 23 GMT 22/ 7/2023 5:53: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.6 9 69 15.01 444 460 0.46 / 316.69 2 23
2 6 4106.8 559 70 14.58 3226 3292 3.75 / 319.99 2 54
3 3 3750.5 740 2 14.82 3089 92 3.84 / 320.08 2 56
4 7 3736.5 12002 80 14.76 3006 3549 7.39 / 323.63 2 61
5 13 2800.6 12230 80 14.77 2359 2787 10.18 / 326.41 2 64
6 13 1946.2 12380 80 14.85 1784 2119 12.30 / 328.53 2 67
7 13 947.5 12548 80 14.98 1102 1321 13.62 / 329.85 2 68
8 13 721.2 12579 80 14.97 934 1119 14.74 / 330.97 2 66
9 14 0.3 12664 93 15.04 414 579 15.32 / 331.55 2 120
10 14 0.4 12664 7 15.03 405 43 15.36 / 331.59 47 142
Average= 13.82
(KJ/cycle)

Cycle 22 GMT 12/ 7/2023 16:11: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.6 9 69 15.01 439 455 0.45 / 300.30 2 24
2 6 3906.4 520 70 14.61 3088 3158 3.61 / 303.46 2 54
3 7 3728.5 5864 80 14.77 2987 3529 7.14 / 306.99 2 61
4 13 2902.4 6050 80 14.77 2420 2859 10.00 / 309.85 2 63
5 13 1992.3 6224 80 14.85 1796 2134 12.14 / 311.98 2 65
6 13 974.8 6386 80 14.99 1100 1319 13.45 / 313.30 2 68
7 13 932.9 6392 80 14.94 1056 1262 14.72 / 314.56 2 69
8 13 735.2 6412 80 14.93 912 1089 15.81 / 315.65 2 74
9 14 0.6 6486 56 15.02 407 342 16.15 / 315.99 2 113
10 14 0.6 6486 44 15.01 363 240 16.39 / 316.23 50 249
Average= 13.75
(KJ/cycle)

Cycle 21 GMT 8/ 7/2023 3:50: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.1 8 69 15.01 431 446 0.45 / 283.91 2 23
2 6 4111.4 554 70 14.59 3231 3300 3.75 / 287.21 2 53
3 3 3736.9 735 2 14.82 3078 91 3.84 / 287.30 2 56
4 7 3701.1 4802 80 14.78 2959 3499 7.34 / 290.80 2 62
5 13 2666.4 5042 80 14.81 2253 2669 10.01 / 293.47 2 63
6 13 1990.6 5168 80 14.85 1789 2125 12.13 / 295.59 2 67
7 13 1111.5 5306 80 14.96 1184 1417 13.55 / 297.01 2 70
8 13 838.9 5342 80 14.97 984 1178 14.73 / 298.19 2 68
9 13 730.5 5354 80 14.93 909 1086 15.81 / 299.28 2 68
10 14 0.4 5427 56 15.03 399 336 16.15 / 299.61 2 118
11 14 0.6 5428 44 15.02 354 234 16.38 / 299.85 53 249
Average= 13.63
(KJ/cycle)

Cycle 20 GMT 3/ 7/2023 14:51: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.3 9 68 15.02 437 446 0.45 / 267.43 2 23
2 6 4111.2 560 70 14.59 3247 3316 3.76 / 270.74 2 52
3 3 3732.0 741 1 14.83 3070 46 3.81 / 270.79 2 56
4 7 3732.4 4983 80 14.78 2991 3537 7.34 / 274.32 2 59
5 13 2834.3 5187 80 14.80 2375 2812 10.16 / 277.14 2 62
6 13 1992.5 5349 80 14.87 1793 2133 12.29 / 279.27 2 64
7 13 998.0 5511 80 14.99 1116 1338 13.63 / 280.61 2 67
8 13 821.2 5535 80 14.98 983 1178 14.81 / 281.78 2 68
9 13 738.7 5543 80 14.94 921 1101 15.91 / 282.89 2 69
10 14 0.3 5617 54 15.03 403 327 16.23 / 283.21 4 106
11 14 0.6 5618 46 15.02 363 251 16.48 / 283.46 39 249
Average= 13.50
(KJ/cycle)

Cycle 19 GMT 29/ 6/2023 1:39: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.2 9 69 15.02 442 458 0.46 / 250.93 2 22
2 6 4108.4 560 70 14.59 3244 3313 3.77 / 254.24 2 54
3 7 3714.0 4983 80 14.79 2979 3525 7.30 / 257.76 2 60
4 13 2879.0 5175 80 14.79 2400 2840 10.14 / 260.60 2 62
5 13 1999.2 5337 80 14.87 1794 2134 12.27 / 262.74 2 66
6 13 995.0 5499 80 15.00 1106 1327 13.60 / 264.07 2 67
7 13 908.7 5511 80 14.96 1043 1248 14.85 / 265.31 2 68
8 13 714.5 5531 80 14.95 908 1086 15.93 / 266.40 2 73
9 14 0.6 5604 56 15.04 405 341 16.27 / 266.74 4 123
10 14 0.7 5604 44 15.03 360 238 16.51 / 266.98 56 249
Average= 13.35
(KJ/cycle)

Cycle 18 GMT 24/ 6/2023 12:40: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.0 9 68 15.03 442 452 0.45 / 234.29 2 22
2 6 4006.2 534 70 14.62 3161 3235 3.69 / 237.53 2 52
3 3 3755.0 715 3 14.82 3120 139 3.83 / 237.67 2 56
4 7 3717.6 4802 80 14.79 2983 3529 7.35 / 241.20 2 60
5 13 2790.5 5000 80 14.81 2345 2778 10.13 / 243.97 2 64
6 13 1984.8 5150 80 14.87 1800 2141 12.27 / 246.12 2 63
7 13 1025.5 5306 80 15.00 1135 1362 13.64 / 247.48 2 68
8 13 984.4 5312 80 14.94 1096 1310 14.95 / 248.79 2 70
9 13 728.2 5339 80 14.95 918 1098 16.04 / 249.89 2 72
10 14 0.3 5412 56 15.04 408 344 16.39 / 250.23 2 120
11 14 0.4 5413 44 15.03 362 239 16.63 / 250.47 53 249
Average= 13.18
(KJ/cycle)

Cycle 17 GMT 20/ 6/2023 0:20: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.3 8 68 15.06 439 450 0.45 / 217.82 2 23
2 6 3741.5 486 78 14.64 2976 3398 3.85 / 221.22 2 53
3 7 3591.5 5830 80 14.81 2899 3435 7.28 / 224.66 2 62
4 13 2707.3 6034 80 14.83 2299 2728 10.01 / 227.38 2 62
5 13 1991.6 6160 80 14.87 1804 2146 12.16 / 229.53 2 64
6 13 981.5 6316 80 15.01 1115 1339 13.50 / 230.87 2 66
7 13 941.0 6322 80 14.96 1071 1282 14.78 / 232.15 3 67
8 13 743.2 6343 80 14.95 929 1111 15.89 / 233.26 2 80
9 14 0.5 6417 56 15.05 404 340 16.23 / 233.60 2 128
10 14 0.6 6418 44 15.04 361 239 16.47 / 233.84 57 249
Average= 12.99
(KJ/cycle)

Cycle 16 GMT 15/ 6/2023 13:13: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.7 9 68 15.03 448 458 0.46 / 202.62 2 20
2 6 3786.5 493 76 14.64 3019 3359 3.82 / 205.98 2 53
3 7 3629.0 4983 80 14.81 2932 3474 7.29 / 209.45 2 62
4 13 2822.8 5163 80 14.81 2376 2815 10.11 / 212.27 2 63
5 13 1887.3 5331 80 14.90 1732 2065 12.17 / 214.33 2 65
6 13 970.6 5475 80 15.01 1105 1327 13.50 / 215.66 2 66
7 13 723.5 5507 80 15.01 923 1108 14.61 / 216.77 2 64
8 14 0.2 5591 90 15.08 403 547 15.15 / 217.31 2 112
9 14 0.4 5592 10 15.07 398 60 15.21 / 217.37 44 174
Average= 12.79
(KJ/cycle)

Cycle 15 GMT 11/ 6/2023 1:36: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.6 8 68 15.04 440 450 0.45 / 186.25 2 20
2 6 3830.8 496 73 14.64 3066 3277 3.73 / 189.52 2 53
3 7 3653.2 4802 80 14.82 2949 3496 7.22 / 193.02 2 61
4 13 2781.6 5006 80 14.83 2350 2788 10.01 / 195.81 2 63
5 13 1981.4 5144 80 14.88 1800 2143 12.15 / 197.95 2 65
6 13 979.4 5306 80 15.02 1112 1336 13.49 / 199.29 2 66
7 13 796.4 5330 80 15.00 978 1174 14.66 / 200.46 2 64
8 13 716.7 5339 80 14.96 925 1107 15.77 / 201.57 2 79
9 14 0.3 5410 54 15.06 417 339 16.11 / 201.91 2 104
10 14 0.4 5410 46 15.04 369 255 16.37 / 202.16 43 249
Average= 12.64
(KJ/cycle)

Cycle 14 GMT 6/ 6/2023 13:57: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.2 8 66 15.07 445 443 0.44 / 169.45 2 22
2 6 3982.7 533 70 14.64 3170 3249 3.69 / 172.70 2 54
3 3 3734.1 713 1 14.85 3105 46 3.74 / 172.74 2 56
4 7 3773.0 5877 80 14.80 3041 3601 7.34 / 176.34 2 62
5 13 2981.8 6057 80 14.80 2483 2940 10.28 / 179.28 2 63
6 13 1991.7 6243 80 14.89 1813 2160 12.44 / 181.44 2 65
7 13 1019.2 6399 80 15.02 1135 1364 13.80 / 182.81 2 67
8 13 977.9 6405 80 14.97 1091 1307 15.11 / 184.11 2 69
9 13 718.5 6432 80 14.97 914 1095 16.20 / 185.21 2 67
10 14 0.8 6504 56 15.06 411 347 16.55 / 185.55 2 124
11 14 0.8 6505 44 15.05 367 243 16.79 / 185.80 51 249
Average= 12.39
(KJ/cycle)

Cycle 13 GMT 2/ 6/2023 1:19: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.4 9 69 15.04 452 469 0.47 / 154.37 2 20
2 6 3959.8 533 70 14.64 3140 3218 3.69 / 157.59 2 53
3 7 3676.2 4802 80 14.82 2974 3526 7.21 / 161.12 2 60
4 13 2682.2 5036 80 14.85 2286 2716 9.93 / 163.83 2 62
5 13 1939.1 5168 80 14.90 1770 2110 12.04 / 165.94 2 66
6 13 974.9 5324 80 15.03 1106 1330 13.37 / 167.27 2 67
7 13 724.7 5357 80 15.02 928 1115 14.48 / 168.39 2 65
8 14 0.2 5440 91 15.09 410 563 15.05 / 168.95 2 109
9 14 0.5 5440 9 15.07 404 55 15.10 / 169.00 41 183
Average= 12.07
(KJ/cycle)

Cycle 12 GMT 28/ 5/2023 12:32: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.1 8 69 15.05 441 458 0.46 / 138.19 2 19
2 6 3878.9 525 71 14.65 3083 3207 3.66 / 141.40 2 54
3 7 3645.4 4983 80 14.84 2946 3497 7.16 / 144.90 2 61
4 13 2644.3 5217 80 14.86 2262 2689 9.85 / 147.59 2 62
5 13 1805.6 5367 80 14.93 1682 2009 11.86 / 149.60 2 65
6 13 981.9 5499 80 15.03 1113 1338 13.20 / 150.93 2 68
7 13 938.9 5505 80 14.97 1067 1278 14.48 / 152.21 2 68
8 13 735.2 5525 80 14.97 917 1098 15.57 / 153.31 2 79
9 14 0.7 5600 54 15.06 412 335 15.91 / 153.65 2 118
10 14 0.8 5601 46 15.05 372 258 16.17 / 153.90 51 249
Average= 11.84
(KJ/cycle)

Cycle 11 GMT 24/ 5/2023 0:15: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.2 9 69 15.03 442 458 0.46 / 121.55 2 20
2 6 3869.7 507 71 14.65 3095 3219 3.68 / 124.77 2 53
3 3 3699.5 687 1 14.85 3051 45 3.72 / 124.81 2 55
4 3 3693.1 868 1 14.91 3091 46 3.77 / 124.86 2 56
5 7 3734.9 4802 80 14.82 3014 3573 7.34 / 128.43 2 61
6 13 2843.5 5006 80 14.83 2399 2846 10.19 / 131.28 2 62
7 13 1997.2 5162 80 14.90 1803 2149 12.34 / 133.43 2 64
8 13 989.6 5330 80 15.04 1114 1340 13.68 / 134.77 2 66
9 13 950.9 5336 80 14.98 1076 1289 14.97 / 136.06 2 68
10 13 708.3 5363 80 14.98 906 1086 16.05 / 137.14 2 68
11 14 0.8 5434 56 15.07 413 349 16.40 / 137.49 2 129
12 14 1.0 5435 44 15.06 371 246 16.65 / 137.74 62 249
Average= 11.48
(KJ/cycle)

Cycle 10 GMT 19/ 5/2023 11:58: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.4 8 69 15.07 439 456 0.46 / 105.39 2 19
2 6 3896.4 516 70 14.65 3112 3191 3.65 / 108.58 2 52
3 7 3734.5 482 80 14.76 3000 3542 7.19 / 112.12 2 60
4 13 2709.7 728 80 14.83 2292 2719 9.91 / 114.84 2 61
5 13 1807.0 902 80 14.92 1664 1986 11.90 / 116.82 2 63
6 13 987.3 1034 80 15.03 1095 1317 13.21 / 118.14 2 64
7 13 945.9 1040 80 14.98 1060 1270 14.48 / 119.41 2 69
8 13 728.7 1063 80 14.97 911 1091 15.57 / 120.50 2 66
9 14 0.5 1137 56 15.06 406 342 15.92 / 120.84 2 118
10 14 0.8 1138 44 15.04 367 243 16.16 / 121.09 50 249
Average= 11.01
(KJ/cycle)

Cycle 9 GMT 17/ 5/2023 23:12: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.2 8 72 15.03 441 477 0.48 / 90.39 2 20
2 6 3998.5 553 69 14.63 3190 3220 3.70 / 93.61 2 53
3 7 3650.2 482 80 14.78 2948 3486 7.18 / 97.09 2 59
4 13 2732.1 686 80 14.82 2321 2752 9.93 / 99.85 2 61
5 13 1860.2 842 80 14.90 1718 2048 11.98 / 101.89 2 64
6 13 973.1 980 80 15.02 1095 1316 13.30 / 103.21 2 65
7 13 738.5 1010 80 15.01 925 1111 14.41 / 104.32 2 65
8 14 0.3 1100 95 15.09 404 579 14.99 / 104.90 2 113
9 14 0.5 1100 5 15.08 394 30 15.02 / 104.93 53 122
Average= 10.49
(KJ/cycle)

Cycle 8 GMT 16/ 5/2023 10:24: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.3 8 73 15.06 449 494 0.49 / 73.99 2 18
2 6 4070.6 564 70 14.63 3243 3321 3.81 / 77.31 2 52
3 7 3661.5 663 80 14.78 2966 3507 7.32 / 80.82 2 57
4 13 2801.0 849 80 14.81 2372 2810 10.13 / 83.63 2 59
5 13 1888.2 1017 80 14.90 1744 2079 12.21 / 85.71 2 60
6 13 998.6 1155 80 15.02 1123 1349 13.56 / 87.06 2 62
7 13 773.9 1185 80 15.01 957 1149 14.71 / 88.21 2 65
8 13 735.7 1189 80 14.96 924 1106 15.82 / 89.31 3 71
9 14 0.7 1264 56 15.06 414 349 16.16 / 89.66 2 109
10 14 0.8 1265 44 15.04 378 250 16.41 / 89.91 49 249
Average= 9.99
(KJ/cycle)

Cycle 7 GMT 14/ 5/2023 21:42: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.6 8 79 15.06 453 539 0.54 / 58.79 2 18
2 6 4047.7 568 70 14.64 3242 3322 3.86 / 62.11 2 51
3 7 3560.3 482 80 14.79 2916 3450 7.31 / 65.56 2 57
4 13 2741.9 656 80 14.82 2353 2790 10.10 / 68.35 2 58
5 13 1840.5 812 80 14.90 1714 2043 12.14 / 70.39 2 59
6 13 987.8 944 80 15.02 1120 1346 13.49 / 71.74 2 63
7 13 736.8 977 80 15.01 943 1132 14.62 / 72.87 2 64
8 14 0.6 1062 93 15.08 415 582 15.20 / 73.45 2 123
9 14 0.8 1062 7 15.07 409 43 15.25 / 73.50 50 149
Average= 9.19
(KJ/cycle)

Cycle 6 GMT 13/ 5/2023 9:15: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.0 10 84 15.06 467 591 0.59 / 43.69 2 19
2 6 4008.7 568 64 14.64 3255 3050 3.64 / 46.74 2 51
3 3 3644.5 748 7 14.81 3010 312 3.95 / 47.05 2 54
4 7 3507.6 663 80 14.80 2900 3434 7.39 / 50.49 2 56
5 13 2525.9 903 80 14.86 2210 2627 10.01 / 53.12 2 58
6 13 1736.4 1041 80 14.92 1666 1989 12.00 / 55.10 2 61
7 13 992.0 1155 80 15.01 1135 1363 13.36 / 56.47 2 62
8 13 730.4 1187 80 15.01 954 1146 14.51 / 57.61 2 63
9 14 0.9 1272 86 15.08 422 547 15.06 / 58.16 2 105
10 14 0.8 1272 14 15.07 420 89 15.15 / 58.25 38 249
Average= 8.32
(KJ/cycle)

Cycle 5 GMT 11/ 5/2023 20:21: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.4 8 62 15.18 460 433 0.43 / 27.20 2 17
2 6 4009.9 522 64 14.67 3248 3049 3.48 / 30.25 2 50
3 3 4016.4 703 28 14.73 3253 1342 4.82 / 31.59 2 52
4 3 3634.1 884 7 14.87 3017 314 5.14 / 31.91 2 53
5 7 3432.3 1547 80 14.81 2861 3390 8.53 / 35.30 2 56
6 13 2515.9 1769 80 14.86 2229 2650 11.18 / 37.95 2 57
7 13 1712.2 1907 80 14.92 1657 1978 13.16 / 39.93 2 59
8 13 1000.8 2015 80 15.01 1150 1381 14.54 / 41.31 2 60
9 13 734.2 2048 80 15.01 961 1154 15.69 / 42.46 2 62
10 14 1.0 2133 84 15.08 427 541 16.23 / 43.00 2 112
11 14 1.2 2133 16 15.06 419 101 16.33 / 43.10 46 249
Average= 7.18
(KJ/cycle)

Cycle 4 GMT 10/ 5/2023 8:33:59

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.8 11 244 15.16 458 1694 1.69 / 22.59 2 21
2 6 1010.4 195 60 15.05 1138 1028 2.72 / 23.62 2 36
3 3 729.4 316 6 15.17 968 88 2.81 / 23.71 2 40
4 7 508.2 1040 80 15.29 795 972 3.78 / 24.68 2 42
5 13 477.8 1046 80 15.24 764 931 4.71 / 25.61 2 46
6 13 27.8 1103 80 15.23 440 536 5.25 / 26.15 2 39
7 14 0.6 1111 56 15.21 420 358 5.61 / 26.50 2 103
8 14 0.6 1112 44 15.20 397 266 5.87 / 26.77 33 249
Average= 5.35
(KJ/cycle)

Cycle 3 GMT 9/ 5/2023 13:53: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.7 11 243 15.21 459 1696 1.70 / 17.01 2 21
2 6 1012.9 195 60 15.07 1144 1034 2.73 / 18.04 2 36
3 3 740.1 316 7 15.18 996 106 2.84 / 18.15 2 39
4 7 486.3 1040 80 15.30 780 955 3.79 / 19.10 2 42
5 13 457.2 1046 80 15.25 754 920 4.71 / 20.02 2 46
6 14 0.3 1107 138 15.23 416 874 5.59 / 20.90 2 100
Average= 5.22
(KJ/cycle)

Cycle 2 GMT 8/ 5/2023 19:14: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.4 11 259 15.24 453 1788 1.79 / 12.01 2 16
2 6 1009.4 2 59 15.08 1163 1035 2.82 / 13.05 2 37
3 7 208.6 847 80 15.35 600 737 3.56 / 13.79 2 31
4 13 178.2 853 80 15.32 570 699 4.26 / 14.48 2 35
5 14 0.6 879 125 15.28 433 827 5.09 / 15.31 2 112
Average= 5.10
(KJ/cycle)

Cycle 1 GMT 8/ 5/2023 0:33: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.9 13 279 15.11 442 1863 1.86 / 7.09 2 17
2 6 1005.6 38 59 15.07 1181 1050 2.91 / 8.14 2 38
3 7 104.3 882 80 15.38 506 623 3.54 / 8.76 2 28
4 13 71.6 888 80 15.35 476 585 4.12 / 9.34 2 33
5 14 0.0 903 138 15.31 417 881 5.00 / 10.23 2 115
Average= 5.11
(KJ/cycle)

Cycle 0 GMT 7/ 5/2023 5:26: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 110.3 23934 402 15.36 469 2896 2.90 / 2.90 2 19
2 7 181.3 23936 80 15.27 487 595 3.49 / 3.49 2 15
3 13 165.8 23942 80 15.24 477 582 4.07 / 4.07 2 17
4 14 0.8 23972 198 15.19 383 1152 5.22 / 5.22 2 108
Average= 5.22
(KJ/cycle)