SIO Argo Site:
Pump Diagnostics Page   



Serial= 3120 WMO= 5906910

Return

←PreviousNext→

Cycle 75 GMT 15/12/2024 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 37 15.06 475 265 0.26 / 309.95 2 3
2 7 2006.96 38 14.64 3093 1721 1.99 / 311.67 2 3
3 13 1630.40 18 14.69 2617 692 2.68 / 312.36 2 3
4 13 1043.40 18 14.83 1809 483 3.16 / 312.85 2 4
5 13 391.92 18 15.05 879 238 3.40 / 313.08 2 3
6 8 0.32 165 15.14 272 679 4.08 / 313.76 2 4
Average= 4.13
(KJ/cycle)

Cycle 74 GMT 5/12/2024 23:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 37 15.06 463 258 0.26 / 305.84 2 3
2 7 2022.40 38 14.63 3118 1733 1.99 / 307.57 2 3
3 13 1612.88 18 14.71 2592 686 2.68 / 308.26 2 3
4 13 1130.44 18 14.81 1931 515 3.19 / 308.77 2 3
5 13 380.76 18 15.05 862 234 3.43 / 309.01 2 3
6 8 0.00 165 15.15 272 680 4.11 / 309.69 2 3
Average= 4.13
(KJ/cycle)

Cycle 73 GMT 26/11/2024 4:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 37 15.08 478 267 0.27 / 301.62 2 3
2 7 2018.32 38 14.64 3120 1736 2.00 / 303.35 2 3
3 13 1612.20 18 14.72 2586 685 2.69 / 304.04 2 3
4 13 1041.00 18 14.85 1802 482 3.17 / 304.52 2 4
5 13 452.04 18 15.04 965 261 3.43 / 304.78 2 3
6 8 -0.20 165 15.15 270 675 4.11 / 305.46 2 3
7 14 -0.20 30 15.13 272 123 4.23 / 305.58 2 4
Average= 4.13
(KJ/cycle)

Cycle 72 GMT 16/11/2024 10:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 37 15.10 471 263 0.26 / 297.53 2 3
2 7 2007.24 38 14.63 3103 1725 1.99 / 299.25 2 3
3 13 1636.32 18 14.72 2624 695 2.68 / 299.95 2 3
4 13 1061.20 18 14.85 1835 490 3.17 / 300.44 2 3
5 13 391.44 18 15.07 879 238 3.41 / 300.68 2 3
6 8 0.20 165 15.16 270 675 4.09 / 301.35 2 3
Average= 4.13
(KJ/cycle)

Cycle 71 GMT 6/11/2024 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 37 15.07 473 264 0.26 / 293.41 2 3
2 7 2019.36 38 14.64 3128 1740 2.00 / 295.15 2 2
3 13 1609.00 18 14.72 2590 686 2.69 / 295.84 2 3
4 13 1081.72 18 14.84 1867 499 3.19 / 296.34 2 3
5 13 425.24 18 15.05 927 251 3.44 / 296.59 2 3
6 8 -0.04 165 15.17 269 673 4.11 / 297.26 2 3
Average= 4.13
(KJ/cycle)

Cycle 70 GMT 27/10/2024 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 37 15.09 474 265 0.26 / 289.14 2 3
2 7 2005.92 39 14.65 3111 1777 2.04 / 290.91 2 2
3 13 1592.64 18 14.73 2572 682 2.72 / 291.60 2 3
4 13 1134.36 18 14.82 1938 517 3.24 / 292.11 2 3
5 13 396.84 18 15.05 887 240 3.48 / 292.35 2 3
6 8 0.28 165 15.14 270 674 4.16 / 293.03 2 3
7 14 0.28 30 15.12 271 123 4.28 / 293.15 2 4
Average= 4.13
(KJ/cycle)

Cycle 69 GMT 18/10/2024 2:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 37 15.09 476 266 0.27 / 285.03 2 3
2 7 2019.72 39 14.64 3133 1789 2.05 / 286.82 2 3
3 13 1595.64 18 14.72 2566 680 2.73 / 287.50 2 3
4 13 1096.60 18 14.83 1887 504 3.24 / 288.00 2 4
5 13 281.64 18 15.11 719 196 3.43 / 288.20 2 3
6 8 0.04 165 15.17 269 673 4.11 / 288.87 2 3
Average= 4.13
(KJ/cycle)

Cycle 68 GMT 8/10/2024 7:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 37 15.09 474 265 0.26 / 280.91 2 3
2 7 2021.84 38 14.65 3136 1746 2.01 / 282.65 2 3
3 13 1608.20 18 14.73 2603 690 2.70 / 283.34 2 3
4 13 1069.16 18 14.84 1854 495 3.20 / 283.84 2 3
5 13 420.52 18 15.06 923 250 3.45 / 284.09 2 4
6 8 0.28 165 15.15 270 675 4.12 / 284.76 2 4
Average= 4.13
(KJ/cycle)

Cycle 67 GMT 28/ 9/2024 13: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 37 15.08 472 263 0.26 / 276.81 2 3
2 7 2019.56 38 14.65 3131 1743 2.01 / 278.55 2 3
3 13 1553.56 18 14.75 2516 668 2.67 / 279.22 2 3
4 13 1111.60 18 14.83 1914 511 3.19 / 279.73 2 3
5 13 362.20 18 15.08 842 229 3.41 / 279.96 2 3
6 8 0.00 165 15.17 274 686 4.10 / 280.64 2 3
Average= 4.13
(KJ/cycle)

Cycle 66 GMT 18/ 9/2024 18:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 37 15.12 457 256 0.26 / 272.56 2 3
2 7 2023.96 38 14.64 3130 1741 2.00 / 274.30 2 3
3 13 1607.20 18 14.71 2601 689 2.69 / 274.99 2 3
4 13 1123.60 18 14.83 1929 515 3.20 / 275.51 2 3
5 13 385.28 18 15.07 871 236 3.44 / 275.74 2 4
6 8 0.20 165 15.16 271 678 4.11 / 276.42 2 3
7 14 0.20 30 15.14 272 124 4.24 / 276.54 2 2
Average= 4.13
(KJ/cycle)

Cycle 65 GMT 8/ 9/2024 23:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 37 15.10 481 269 0.27 / 268.27 2 3
2 7 2022.40 38 14.67 3130 1745 2.01 / 270.01 2 3
3 13 1618.92 18 14.74 2615 694 2.71 / 270.71 2 3
4 13 1131.60 18 14.84 1943 519 3.23 / 271.23 2 3
5 13 487.92 18 15.06 1025 278 3.50 / 271.51 2 4
6 8 -0.20 165 15.17 270 676 4.18 / 272.18 2 3
7 14 -0.20 30 15.16 272 124 4.30 / 272.30 2 4
Average= 4.13
(KJ/cycle)

Cycle 64 GMT 30/ 8/2024 4:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 37 15.11 478 267 0.27 / 264.00 2 3
2 7 2022.60 38 14.66 3137 1748 2.01 / 265.75 2 3
3 13 1651.72 18 14.73 2654 704 2.72 / 266.45 2 3
4 13 1062.32 18 14.88 1849 495 3.21 / 266.95 2 3
5 13 423.92 18 15.08 928 252 3.47 / 267.20 2 3
6 8 0.48 165 15.18 271 679 4.14 / 267.88 2 3
7 14 0.48 30 15.16 272 124 4.27 / 268.00 2 2
Average= 4.12
(KJ/cycle)

Cycle 63 GMT 20/ 8/2024 10:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 37 15.10 468 261 0.26 / 259.74 2 3
2 7 2022.32 38 14.65 3132 1744 2.01 / 261.48 2 3
3 13 1602.64 18 14.75 2586 687 2.69 / 262.17 2 3
4 13 1071.24 18 14.87 1852 496 3.19 / 262.67 2 3
5 13 419.72 18 15.07 920 250 3.44 / 262.92 2 4
6 8 7.64 165 15.17 277 693 4.13 / 263.61 2 3
7 14 7.64 30 15.16 272 124 4.25 / 263.73 2 4
Average= 4.12
(KJ/cycle)

Cycle 62 GMT 10/ 8/2024 15:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 36 15.09 471 256 0.26 / 255.63 2 3
2 7 2007.80 38 14.66 3100 1727 1.98 / 257.36 2 3
3 13 1631.44 18 14.73 2611 692 2.68 / 258.05 2 3
4 13 1094.40 18 14.85 1878 502 3.18 / 258.56 2 3
5 13 404.60 18 15.08 898 244 3.42 / 258.80 2 4
6 8 0.48 165 15.19 271 679 4.10 / 259.48 2 2
Average= 4.12
(KJ/cycle)

Cycle 61 GMT 31/ 7/2024 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 36 15.10 445 242 0.24 / 251.55 2 3
2 7 2021.16 38 14.67 3129 1744 1.99 / 253.30 2 3
3 13 1563.08 18 14.76 2522 670 2.66 / 253.97 2 3
4 13 1080.76 18 14.87 1861 498 3.15 / 254.46 2 3
5 13 382.76 18 15.10 866 235 3.39 / 254.70 2 3
6 8 0.00 165 15.18 271 679 4.07 / 255.38 2 3
Average= 4.12
(KJ/cycle)

Cycle 60 GMT 22/ 7/2024 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 36 15.13 443 241 0.24 / 247.50 2 3
2 7 2009.48 38 14.67 3104 1730 1.97 / 249.23 2 3
3 13 1565.68 18 14.77 2528 672 2.64 / 249.90 2 3
4 13 1127.84 18 14.86 1925 515 3.16 / 250.41 2 3
5 13 334.40 18 15.13 794 216 3.37 / 250.63 2 3
6 8 0.08 165 15.20 271 680 4.05 / 251.31 2 3
Average= 4.12
(KJ/cycle)

Cycle 59 GMT 12/ 7/2024 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 36 15.12 472 257 0.26 / 243.27 2 3
2 7 2017.68 38 14.67 3124 1742 2.00 / 245.01 2 3
3 13 1633.68 18 14.75 2620 696 2.69 / 245.71 2 3
4 13 1086.72 18 14.87 1874 502 3.20 / 246.21 2 3
5 13 401.40 18 15.11 892 243 3.44 / 246.45 2 3
6 8 0.16 165 15.19 272 682 4.12 / 247.13 2 2
7 14 0.16 30 15.18 272 124 4.24 / 247.26 2 4
Average= 4.12
(KJ/cycle)

Cycle 58 GMT 2/ 7/2024 12:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 36 15.12 469 255 0.26 / 239.18 2 3
2 7 2023.20 38 14.68 3134 1748 2.00 / 240.93 2 2
3 13 1588.88 18 14.77 2560 681 2.68 / 241.61 2 3
4 13 1066.36 18 14.90 1846 495 3.18 / 242.10 2 3
5 13 376.52 18 15.11 857 233 3.41 / 242.33 2 4
6 8 0.04 165 15.21 270 678 4.09 / 243.01 2 3
Average= 4.12
(KJ/cycle)

Cycle 57 GMT 22/ 6/2024 18:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 36 15.15 455 248 0.25 / 235.13 2 2
2 7 2023.24 38 14.67 3130 1745 1.99 / 236.88 2 3
3 13 1562.20 18 14.76 2531 672 2.67 / 237.55 2 3
4 13 1036.56 18 14.88 1806 484 3.15 / 238.03 2 4
5 13 310.52 18 15.13 763 208 3.36 / 238.24 2 3
6 8 0.32 165 15.20 271 680 4.04 / 238.92 2 3
Average= 4.12
(KJ/cycle)

Cycle 56 GMT 12/ 6/2024 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 36 15.14 470 256 0.26 / 230.94 2 3
2 7 2020.48 38 14.67 3124 1742 2.00 / 232.68 2 2
3 13 1590.64 18 14.76 2564 681 2.68 / 233.37 2 3
4 13 1052.88 18 14.89 1819 488 3.17 / 233.85 2 3
5 13 375.36 18 15.13 856 233 3.40 / 234.09 2 3
6 8 0.32 165 15.22 269 676 4.08 / 234.76 2 2
7 14 0.32 30 15.18 272 124 4.20 / 234.89 2 2
Average= 4.12
(KJ/cycle)

Cycle 55 GMT 3/ 6/2024 4:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 36 15.13 470 256 0.26 / 226.85 2 3
2 7 2022.64 38 14.68 3125 1743 2.00 / 228.59 2 3
3 13 1603.80 18 14.77 2585 687 2.69 / 229.28 2 3
4 13 1069.00 18 14.89 1847 495 3.18 / 229.77 2 3
5 13 378.20 18 15.12 859 234 3.42 / 230.01 2 3
6 8 -0.24 165 15.22 270 678 4.09 / 230.69 2 3
Average= 4.12
(KJ/cycle)

Cycle 54 GMT 24/ 5/2024 10: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 36 15.15 470 256 0.26 / 222.63 2 3
2 7 2018.12 38 14.67 3126 1743 2.00 / 224.37 2 3
3 13 1630.88 18 14.75 2629 698 2.70 / 225.07 2 3
4 13 1000.80 18 14.92 1758 472 3.17 / 225.54 2 3
5 13 407.68 18 15.11 906 246 3.42 / 225.79 2 4
6 8 0.04 165 15.21 271 680 4.10 / 226.47 2 3
7 14 0.04 30 15.20 272 124 4.22 / 226.59 2 3
Average= 4.12
(KJ/cycle)

Cycle 53 GMT 14/ 5/2024 15:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 36 15.13 472 257 0.26 / 218.38 2 3
2 7 2021.92 38 14.68 3134 1748 2.01 / 220.12 2 3
3 13 1687.32 18 14.74 2708 718 2.72 / 220.84 2 3
4 13 1055.92 18 14.90 1830 491 3.21 / 221.33 2 3
5 13 386.04 18 15.11 872 237 3.45 / 221.57 2 3
6 8 0.20 165 15.21 271 680 4.13 / 222.25 2 3
7 14 0.20 30 15.20 271 124 4.26 / 222.37 2 4
Average= 4.12
(KJ/cycle)

Cycle 52 GMT 4/ 5/2024 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 36 15.17 443 242 0.24 / 214.30 2 3
2 7 2008.44 39 14.68 3108 1779 2.02 / 216.08 2 3
3 13 1549.80 18 14.77 2512 668 2.69 / 216.74 2 3
4 13 1063.44 18 14.90 1845 495 3.18 / 217.24 2 3
5 13 287.16 18 15.17 729 199 3.38 / 217.44 2 3
6 8 0.12 165 15.22 271 681 4.06 / 218.12 2 6
Average= 4.12
(KJ/cycle)

Cycle 51 GMT 25/ 4/2024 1:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 36 15.15 460 251 0.25 / 210.23 2 3
2 7 2010.60 38 14.70 3120 1743 1.99 / 211.97 2 3
3 13 1637.48 18 14.79 2627 699 2.69 / 212.67 2 3
4 13 1038.52 18 14.92 1803 484 3.18 / 213.15 2 3
5 13 358.80 18 15.15 831 227 3.40 / 213.38 2 3
6 8 0.20 165 15.23 269 676 4.08 / 214.05 2 3
Average= 4.12
(KJ/cycle)

Cycle 50 GMT 15/ 4/2024 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 36 15.16 463 253 0.25 / 206.16 2 3
2 7 2023.52 38 14.67 3123 1741 1.99 / 207.90 2 3
3 13 1608.96 18 14.76 2584 687 2.68 / 208.59 2 3
4 13 1023.00 18 14.93 1786 480 3.16 / 209.07 2 3
5 13 376.28 18 15.13 855 233 3.39 / 209.30 2 4
6 8 0.04 165 15.22 268 673 4.07 / 209.97 2 3
Average= 4.12
(KJ/cycle)

Cycle 49 GMT 5/ 4/2024 12:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 36 15.15 447 244 0.24 / 202.14 2 3
2 7 2020.32 38 14.69 3121 1742 1.99 / 203.88 2 3
3 13 1557.56 18 14.79 2511 668 2.65 / 204.55 2 3
4 13 1034.48 18 14.92 1800 483 3.14 / 205.03 2 3
5 13 301.72 18 15.17 744 203 3.34 / 205.23 2 3
6 8 0.16 165 15.22 269 676 4.02 / 205.91 2 4
Average= 4.12
(KJ/cycle)

Cycle 48 GMT 26/ 3/2024 17:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 36 15.15 461 251 0.25 / 198.02 2 3
2 7 2007.28 39 14.70 3096 1775 2.03 / 199.80 2 3
3 13 1638.32 18 14.79 2622 698 2.72 / 200.50 2 3
4 13 1040.44 18 14.93 1804 485 3.21 / 200.98 2 3
5 13 380.20 18 15.14 859 234 3.44 / 201.22 2 3
6 8 0.20 165 15.23 269 676 4.12 / 201.89 2 2
Average= 4.12
(KJ/cycle)

Cycle 47 GMT 16/ 3/2024 23:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 36 15.16 454 248 0.25 / 193.98 2 3
2 7 2020.64 38 14.71 3109 1738 1.99 / 195.71 2 3
3 13 1606.12 18 14.79 2578 686 2.67 / 196.40 2 3
4 13 1032.40 18 14.94 1785 480 3.15 / 196.88 2 3
5 13 347.60 18 15.16 810 221 3.37 / 197.10 2 3
6 8 0.08 165 15.23 267 671 4.04 / 197.77 2 3
Average= 4.12
(KJ/cycle)

Cycle 46 GMT 7/ 3/2024 4:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.08 36 15.15 470 256 0.26 / 189.89 2 3
2 7 2021.16 38 14.69 3127 1746 2.00 / 191.63 2 3
3 13 1569.28 18 14.81 2531 675 2.68 / 192.31 2 3
4 13 1057.16 18 14.94 1823 490 3.17 / 192.80 2 3
5 13 440.96 18 15.13 946 258 3.42 / 193.05 2 3
6 8 0.20 165 15.24 268 674 4.10 / 193.73 2 4
Average= 4.12
(KJ/cycle)

Cycle 45 GMT 26/ 2/2024 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 36 15.15 465 254 0.25 / 185.80 2 3
2 7 2016.80 38 14.69 3108 1735 1.99 / 187.54 2 2
3 13 1637.60 18 14.78 2614 695 2.68 / 188.23 2 3
4 13 1040.64 18 14.93 1800 484 3.17 / 188.72 2 3
5 13 390.76 18 15.14 876 239 3.41 / 188.95 2 3
6 8 0.04 165 15.23 269 676 4.08 / 189.63 2 3
Average= 4.12
(KJ/cycle)

Cycle 44 GMT 16/ 2/2024 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 36 15.17 452 247 0.25 / 181.70 2 2
2 7 2023.68 38 14.70 3109 1737 1.98 / 183.44 2 3
3 13 1605.52 18 14.79 2578 686 2.67 / 184.12 2 3
4 13 1062.52 18 14.92 1826 490 3.16 / 184.61 2 3
5 13 445.64 18 15.13 951 259 3.42 / 184.87 2 3
6 8 0.20 165 15.23 269 676 4.10 / 185.55 2 4
Average= 4.12
(KJ/cycle)

Cycle 43 GMT 6/ 2/2024 20:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 36 15.16 468 255 0.26 / 177.56 2 3
2 7 2006.84 38 14.72 3101 1735 1.99 / 179.30 2 3
3 13 1583.64 18 14.81 2544 678 2.67 / 179.98 2 3
4 13 1041.92 18 14.93 1806 485 3.15 / 180.46 2 3
5 13 384.72 18 15.16 865 236 3.39 / 180.70 2 4
6 13 15.52 18 15.27 300 82 3.47 / 180.78 2 3
7 8 0.20 165 15.23 268 673 4.15 / 181.45 2 3
Average= 4.12
(KJ/cycle)

Cycle 42 GMT 28/ 1/2024 2:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 36 15.18 461 252 0.25 / 173.44 2 3
2 7 2007.60 38 14.71 3100 1733 1.98 / 175.17 2 3
3 13 1626.12 18 14.78 2621 697 2.68 / 175.87 2 3
4 13 1094.16 18 14.92 1879 505 3.19 / 176.37 2 4
5 13 450.12 18 15.13 957 261 3.45 / 176.63 2 3
6 8 -0.12 165 15.24 269 676 4.12 / 177.31 2 3
Average= 4.12
(KJ/cycle)

Cycle 41 GMT 18/ 1/2024 7:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 36 15.17 463 253 0.25 / 169.30 2 3
2 7 2022.08 38 14.70 3119 1742 2.00 / 171.04 2 2
3 13 1641.56 18 14.79 2622 698 2.69 / 171.74 2 3
4 13 1098.48 18 14.93 1891 508 3.20 / 172.25 2 3
5 13 434.32 18 15.16 937 256 3.46 / 172.51 2 3
6 8 0.28 165 15.25 269 677 4.13 / 173.18 2 3
Average= 4.12
(KJ/cycle)

Cycle 40 GMT 8/ 1/2024 13:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 36 15.19 456 249 0.25 / 165.10 2 3
2 7 2023.20 38 14.70 3128 1747 2.00 / 166.84 2 3
3 13 1608.44 18 14.80 2584 688 2.69 / 167.53 2 3
4 13 1030.28 18 14.95 1785 480 3.17 / 168.01 2 3
5 13 380.96 18 15.16 862 235 3.40 / 168.25 2 3
6 8 0.20 165 15.25 270 679 4.08 / 168.93 2 3
7 14 0.20 30 15.21 270 123 4.20 / 169.05 2 3
Average= 4.12
(KJ/cycle)

Cycle 39 GMT 29/12/2023 18:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 36 15.17 455 248 0.25 / 160.86 2 3
2 7 2023.36 38 14.72 3136 1754 2.00 / 162.61 2 3
3 13 1638.32 18 14.80 2618 697 2.70 / 163.31 2 3
4 13 1096.60 18 14.93 1879 505 3.21 / 163.81 2 4
5 13 345.36 18 15.19 812 222 3.43 / 164.03 2 3
6 8 0.04 165 15.26 273 687 4.11 / 164.72 2 3
7 14 0.04 30 15.23 273 125 4.24 / 164.85 3 3
Average= 4.12
(KJ/cycle)

Cycle 38 GMT 19/12/2023 23:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 36 15.19 462 253 0.25 / 156.77 2 3
2 7 2006.08 39 14.73 3104 1783 2.04 / 158.55 2 3
3 13 1594.04 18 14.81 2579 688 2.72 / 159.24 2 3
4 13 1053.84 18 14.94 1824 491 3.21 / 159.73 2 3
5 13 276.64 18 15.21 708 194 3.41 / 159.92 2 3
6 8 0.24 165 15.26 271 682 4.09 / 160.61 2 2
Average= 4.12
(KJ/cycle)

Cycle 37 GMT 10/12/2023 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 36 15.21 457 250 0.25 / 152.56 2 3
2 7 2018.68 38 14.71 3127 1748 2.00 / 154.31 2 3
3 13 1599.88 18 14.81 2579 688 2.69 / 154.99 2 3
4 13 1060.84 18 14.96 1833 494 3.18 / 155.49 2 3
5 13 364.80 18 15.18 838 229 3.41 / 155.72 2 3
6 8 -0.08 165 15.26 269 677 4.09 / 156.39 2 2
7 14 -0.08 30 15.25 271 124 4.21 / 156.52 2 4
Average= 4.12
(KJ/cycle)

Cycle 36 GMT 30/11/2023 10:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 36 15.18 462 252 0.25 / 148.45 2 3
2 7 2021.72 38 14.71 3124 1746 2.00 / 150.20 2 3
3 13 1635.96 18 14.80 2633 701 2.70 / 150.90 2 3
4 13 1051.20 18 14.95 1815 488 3.19 / 151.39 2 3
5 13 393.40 18 15.18 880 240 3.43 / 151.63 2 3
6 8 -0.20 165 15.27 269 678 4.11 / 152.31 2 3
Average= 4.12
(KJ/cycle)

Cycle 35 GMT 20/11/2023 16: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 36 15.19 465 254 0.25 / 144.38 2 3
2 7 2021.08 38 14.72 3133 1752 2.01 / 146.13 2 3
3 13 1552.32 18 14.82 2523 673 2.68 / 146.80 2 3
4 13 1066.72 18 14.94 1846 496 3.18 / 147.30 2 3
5 13 335.88 18 15.19 799 218 3.39 / 147.52 2 4
6 8 0.12 165 15.27 272 685 4.08 / 148.20 2 5
Average= 4.12
(KJ/cycle)

Cycle 34 GMT 10/11/2023 21:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 36 15.20 462 253 0.25 / 140.19 2 3
2 7 2022.00 38 14.72 3135 1754 2.01 / 141.94 2 3
3 13 1586.88 18 14.83 2570 686 2.69 / 142.63 2 3
4 13 1011.04 18 14.97 1766 476 3.17 / 143.10 2 3
5 13 336.32 18 15.20 802 219 3.39 / 143.32 2 3
6 8 0.08 165 15.28 268 676 4.06 / 144.00 2 4
7 14 0.08 30 15.26 269 123 4.19 / 144.12 2 4
Average= 4.12
(KJ/cycle)

Cycle 33 GMT 1/11/2023 2:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 36 15.19 455 249 0.25 / 135.95 2 3
2 7 2019.80 39 14.70 3131 1795 2.04 / 137.74 2 3
3 13 1550.56 18 14.81 2528 674 2.72 / 138.42 2 3
4 13 1055.84 18 14.94 1826 491 3.21 / 138.91 2 3
5 13 352.52 18 15.18 823 225 3.43 / 139.13 2 3
6 8 0.28 165 15.28 269 678 4.11 / 139.81 2 5
7 14 0.28 30 15.26 271 124 4.24 / 139.93 2 8
Average= 4.12
(KJ/cycle)

Cycle 32 GMT 22/10/2023 8: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 36 15.21 457 250 0.25 / 131.71 2 3
2 7 2018.40 38 14.73 3140 1758 2.01 / 133.47 2 3
3 13 1590.92 18 14.82 2576 687 2.69 / 134.16 2 3
4 13 1052.92 18 14.96 1831 493 3.19 / 134.65 2 3
5 13 407.48 18 15.18 906 248 3.44 / 134.90 2 4
6 8 0.20 165 15.28 269 678 4.11 / 135.57 2 2
7 14 0.20 30 15.26 270 124 4.24 / 135.70 3 2
Average= 4.11
(KJ/cycle)

Cycle 31 GMT 12/10/2023 13:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 36 15.21 462 253 0.25 / 127.66 2 3
2 7 2005.80 38 14.73 3115 1744 2.00 / 129.40 2 3
3 13 1553.84 18 14.85 2527 675 2.67 / 130.08 2 3
4 13 1065.12 18 14.95 1847 497 3.17 / 130.58 2 3
5 13 300.76 18 15.22 743 204 3.37 / 130.78 2 3
6 8 0.40 165 15.29 270 681 4.05 / 131.46 2 3
Average= 4.11
(KJ/cycle)

Cycle 30 GMT 2/10/2023 18:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 36 15.23 471 258 0.26 / 123.52 2 3
2 7 2007.16 38 14.74 3118 1746 2.00 / 125.27 2 3
3 13 1626.08 18 14.83 2622 700 2.70 / 125.97 2 3
4 13 1079.44 18 14.97 1867 503 3.21 / 126.47 2 3
5 13 429.00 18 15.19 933 255 3.46 / 126.72 2 4
6 8 -0.04 165 15.29 271 684 4.15 / 127.41 2 3
Average= 4.11
(KJ/cycle)

Cycle 29 GMT 23/ 9/2023 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 36 15.22 467 256 0.26 / 119.40 2 3
2 7 2019.72 38 14.74 3134 1755 2.01 / 121.15 2 3
3 13 1601.00 18 14.84 2587 691 2.70 / 121.84 2 3
4 13 1055.72 18 14.97 1832 494 3.20 / 122.34 2 3
5 13 397.96 18 15.20 893 244 3.44 / 122.58 2 4
6 8 0.12 165 15.28 270 681 4.12 / 123.26 2 3
Average= 4.11
(KJ/cycle)

Cycle 28 GMT 13/ 9/2023 5:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 36 15.24 479 263 0.26 / 115.20 2 3
2 7 2009.52 38 14.73 3131 1753 2.02 / 116.95 2 2
3 13 1619.40 18 14.84 2612 698 2.71 / 117.65 2 3
4 13 984.16 18 15.00 1740 470 3.18 / 118.12 2 4
5 13 306.52 18 15.24 762 209 3.39 / 118.33 2 4
6 8 0.00 165 15.32 272 688 4.08 / 119.01 2 3
7 14 0.00 30 15.29 273 125 4.20 / 119.14 2 3
Average= 4.11
(KJ/cycle)

Cycle 27 GMT 3/ 9/2023 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 36 15.24 471 258 0.26 / 111.09 2 3
2 7 2022.72 38 14.73 3143 1759 2.02 / 112.85 2 2
3 13 1585.76 18 14.84 2563 685 2.70 / 113.53 2 3
4 13 1046.36 18 14.98 1829 493 3.20 / 114.03 2 3
5 13 331.36 18 15.23 797 218 3.41 / 114.25 2 4
6 8 0.12 165 15.30 273 689 4.10 / 114.94 2 3
Average= 4.10
(KJ/cycle)

Cycle 26 GMT 24/ 8/2023 16: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 35 15.24 477 254 0.25 / 106.88 2 3
2 7 2022.92 38 14.73 3144 1760 2.01 / 108.64 2 3
3 13 1565.68 18 14.83 2546 680 2.69 / 109.32 2 3
4 13 982.88 18 14.99 1738 469 3.16 / 109.79 2 3
5 13 334.40 18 15.23 808 222 3.38 / 110.01 2 4
6 8 0.12 165 15.31 275 695 4.08 / 110.70 2 2
7 14 0.12 30 15.29 277 127 4.21 / 110.83 2 3
Average= 4.10
(KJ/cycle)

Cycle 25 GMT 14/ 8/2023 21:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 35 15.25 458 244 0.24 / 102.73 2 3
2 7 2006.76 38 14.76 3119 1749 1.99 / 104.48 2 3
3 13 1595.16 18 14.85 2583 690 2.68 / 105.17 2 3
4 13 1061.48 18 14.98 1849 499 3.18 / 105.67 2 4
5 13 424.44 18 15.20 936 256 3.44 / 105.93 2 4
6 8 0.24 165 15.31 276 697 4.14 / 106.63 2 3
Average= 4.10
(KJ/cycle)

Cycle 24 GMT 5/ 8/2023 2:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 35 15.24 464 247 0.25 / 98.55 2 3
2 7 2020.92 38 14.75 3130 1754 2.00 / 100.31 2 3
3 13 1545.76 18 14.89 2512 673 2.68 / 100.98 2 3
4 13 968.28 18 15.04 1714 464 3.14 / 101.44 2 3
5 13 332.84 18 15.25 803 220 3.36 / 101.66 2 4
6 8 0.12 165 15.33 276 698 4.06 / 102.36 2 3
7 14 0.12 30 15.31 278 128 4.19 / 102.49 2 3
Average= 4.10
(KJ/cycle)

Cycle 23 GMT 26/ 7/2023 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 35 15.26 482 257 0.26 / 94.40 2 3
2 7 2015.92 38 14.74 3133 1755 2.01 / 96.16 2 3
3 13 1540.72 18 14.87 2509 672 2.68 / 96.83 2 3
4 13 957.36 18 15.02 1699 459 3.14 / 97.29 2 3
5 13 255.56 18 15.27 692 190 3.33 / 97.48 2 4
6 8 0.08 165 15.33 276 698 4.03 / 98.18 2 3
7 14 0.08 30 15.31 279 128 4.16 / 98.30 3 2
Average= 4.10
(KJ/cycle)

Cycle 22 GMT 16/ 7/2023 13: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 35 15.26 479 256 0.26 / 90.31 2 3
2 7 2018.84 38 14.76 3137 1759 2.02 / 92.07 2 3
3 13 1583.72 18 14.85 2570 687 2.70 / 92.75 2 3
4 13 960.84 18 15.03 1705 461 3.16 / 93.22 2 3
5 13 346.28 18 15.24 825 226 3.39 / 93.44 2 4
6 8 0.00 165 15.33 278 703 4.09 / 94.14 2 2
Average= 4.09
(KJ/cycle)

Cycle 21 GMT 6/ 7/2023 18:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 35 15.26 479 256 0.26 / 86.08 2 3
2 7 2022.16 38 14.75 3147 1764 2.02 / 87.85 2 3
3 13 1593.08 18 14.86 2572 688 2.71 / 88.53 2 3
4 13 1042.08 18 15.01 1824 493 3.20 / 89.03 2 3
5 13 269.76 18 15.27 713 196 3.40 / 89.22 2 4
6 8 -0.12 165 15.34 277 701 4.10 / 89.92 2 2
7 14 -0.12 30 15.31 276 127 4.22 / 90.05 2 2
Average= 4.09
(KJ/cycle)

Cycle 20 GMT 26/ 6/2023 23:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 35 15.25 456 243 0.24 / 81.86 2 3
2 3 1020.88 1 15.26 1869 29 0.27 / 81.89 2 3
3 7 2013.16 38 14.75 3135 1757 2.03 / 83.64 2 3
4 13 1519.04 18 14.88 2485 666 2.69 / 84.31 2 3
5 13 1003.12 18 15.02 1772 479 3.17 / 84.79 2 3
6 13 295.92 18 15.27 756 208 3.38 / 85.00 2 4
7 8 -0.04 165 15.34 278 704 4.09 / 85.70 2 2
8 14 -0.04 30 15.32 277 127 4.21 / 85.83 2 3
Average= 4.09
(KJ/cycle)

Cycle 19 GMT 17/ 6/2023 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 35 15.24 479 255 0.26 / 77.85 2 3
2 7 2014.08 38 14.74 3130 1753 2.01 / 79.61 2 3
3 13 1443.76 18 14.90 2373 636 2.65 / 80.24 2 3
4 13 938.96 18 15.03 1679 454 3.10 / 80.70 2 4
5 13 302.20 18 15.25 768 211 3.31 / 80.91 2 4
6 8 0.08 165 15.32 280 708 4.02 / 81.61 2 2
Average= 4.08
(KJ/cycle)

Cycle 18 GMT 7/ 6/2023 9:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 34 15.26 461 239 0.24 / 73.82 2 3
2 7 2006.36 38 14.72 3119 1745 1.98 / 75.56 2 2
3 13 1447.64 18 14.90 2390 641 2.62 / 76.20 2 3
4 13 968.28 18 15.01 1721 465 3.09 / 76.67 2 3
5 13 326.64 18 15.23 805 221 3.31 / 76.89 2 4
6 8 0.20 165 15.32 280 708 4.02 / 77.60 2 3
Average= 4.08
(KJ/cycle)

Cycle 17 GMT 28/ 5/2023 15: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 34 15.26 460 239 0.24 / 69.78 2 3
2 7 2012.24 38 14.73 3129 1751 1.99 / 71.53 2 3
3 13 1499.16 18 14.88 2453 657 2.65 / 72.18 2 3
4 13 993.80 18 15.01 1763 476 3.12 / 72.66 2 4
5 13 295.52 18 15.26 759 208 3.33 / 72.87 2 4
6 8 0.28 165 15.31 281 710 4.04 / 73.58 2 3
Average= 4.09
(KJ/cycle)

Cycle 16 GMT 18/ 5/2023 20:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 34 15.25 456 236 0.24 / 65.70 2 3
2 7 2013.40 38 14.74 3134 1755 1.99 / 67.46 2 3
3 13 1536.72 18 14.88 2506 671 2.66 / 68.13 2 3
4 13 954.68 18 15.03 1704 461 3.12 / 68.59 2 4
5 13 358.76 18 15.23 852 234 3.36 / 68.83 2 4
6 8 0.04 165 15.34 281 711 4.07 / 69.54 2 3
Average= 4.09
(KJ/cycle)

Cycle 15 GMT 9/ 5/2023 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 34 15.27 460 239 0.24 / 61.46 2 3
2 3 1022.28 1 15.26 1868 29 0.27 / 61.49 2 3
3 7 2020.60 38 14.73 3144 1760 2.03 / 63.25 2 3
4 13 1572.36 18 14.88 2548 682 2.71 / 63.93 2 3
5 13 919.32 18 15.05 1660 450 3.16 / 64.38 2 4
6 13 372.08 18 15.23 880 241 3.40 / 64.62 2 4
7 8 -0.12 165 15.34 283 716 4.12 / 65.34 2 3
8 14 -0.12 30 15.31 284 130 4.25 / 65.47 2 2
Average= 4.09
(KJ/cycle)

Cycle 14 GMT 29/ 4/2023 7: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 34 15.26 488 253 0.25 / 57.37 2 3
2 7 2020.36 38 14.75 3147 1764 2.02 / 59.13 2 3
3 13 1494.72 18 14.91 2448 657 2.67 / 59.79 2 3
4 13 950.32 18 15.05 1702 461 3.14 / 60.25 2 3
5 13 398.92 18 15.24 919 252 3.39 / 60.50 2 4
6 8 0.20 165 15.34 284 719 4.11 / 61.22 2 2
Average= 4.08
(KJ/cycle)

Cycle 13 GMT 19/ 4/2023 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 34 15.26 492 255 0.26 / 53.32 2 3
2 7 2014.60 38 14.74 3136 1757 2.01 / 55.07 2 3
3 13 1480.40 18 14.90 2440 654 2.67 / 55.73 2 3
4 13 932.40 18 15.05 1675 454 3.12 / 56.18 2 3
5 13 296.32 18 15.27 767 211 3.33 / 56.39 2 4
6 8 0.24 165 15.34 285 721 4.05 / 57.11 2 2
Average= 4.08
(KJ/cycle)

Cycle 12 GMT 9/ 4/2023 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.00 34 15.26 490 254 0.25 / 49.22 2 3
2 7 2015.04 38 14.74 3144 1761 2.02 / 50.98 2 3
3 13 1525.84 18 14.90 2496 669 2.68 / 51.65 2 3
4 13 889.20 18 15.08 1611 437 3.12 / 52.08 2 4
5 13 393.64 18 15.24 912 250 3.37 / 52.33 2 4
6 8 0.04 165 15.34 288 729 4.10 / 53.06 2 2
Average= 4.08
(KJ/cycle)

Cycle 11 GMT 30/ 3/2023 22:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 34 15.26 476 247 0.25 / 45.00 2 3
2 7 2011.80 38 14.75 3131 1755 2.00 / 46.76 2 3
3 13 1477.28 18 14.92 2420 650 2.65 / 47.41 2 3
4 13 882.88 18 15.08 1609 437 3.09 / 47.85 2 4
5 13 421.52 18 15.23 954 262 3.35 / 48.11 2 4
6 8 0.12 165 15.35 286 724 4.07 / 48.83 2 3
7 14 0.12 30 15.33 283 130 4.20 / 48.96 2 2
Average= 4.08
(KJ/cycle)

Cycle 10 GMT 21/ 3/2023 4: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 34 15.26 484 251 0.25 / 40.96 2 3
2 7 2017.96 38 14.74 3143 1760 2.01 / 42.72 2 3
3 13 1478.48 18 14.91 2439 655 2.67 / 43.38 2 3
4 13 893.08 18 15.06 1613 437 3.10 / 43.81 2 3
5 13 302.16 18 15.27 775 213 3.32 / 44.03 2 4
6 8 0.36 165 15.34 288 729 4.05 / 44.76 2 2
Average= 4.07
(KJ/cycle)

Cycle 9 GMT 11/ 3/2023 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 33 15.28 486 245 0.25 / 36.89 2 3
2 7 2024.80 38 14.75 3149 1765 2.01 / 38.66 2 3
3 13 1496.08 18 14.92 2455 659 2.67 / 39.32 2 3
4 13 913.72 18 15.07 1652 448 3.12 / 39.76 2 3
5 13 309.44 18 15.27 790 217 3.33 / 39.98 2 4
6 8 -0.08 165 15.35 288 729 4.06 / 40.71 2 2
Average= 4.07
(KJ/cycle)

Cycle 8 GMT 1/ 3/2023 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 34 15.25 486 252 0.25 / 32.07 2 3
2 7 2005.60 74 14.64 3119 3379 3.63 / 35.45 2 3
3 13 713.40 18 15.14 1370 373 4.00 / 35.82 2 4
4 13 26.80 18 15.38 338 94 4.10 / 35.91 2 3
5 8 0.00 165 15.35 290 734 4.83 / 36.65 2 2
Average= 4.07
(KJ/cycle)

Cycle 7 GMT 19/ 2/2023 18: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 34 15.27 459 238 0.24 / 26.96 2 3
2 7 2006.40 74 14.64 3121 3381 3.62 / 30.34 2 3
3 13 570.48 18 15.20 1170 320 3.94 / 30.66 2 4
4 13 28.64 18 15.39 341 94 4.03 / 30.76 2 3
5 8 0.20 165 15.35 288 729 4.76 / 31.49 2 2
6 14 0.20 75 15.31 285 327 5.09 / 31.81 2 3
Average= 3.98
(KJ/cycle)

Cycle 6 GMT 9/ 2/2023 21:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 32 15.29 483 236 0.24 / 21.74 2 3
2 10 1004.64 3 15.18 1856 85 0.32 / 21.82 2 3
3 7 2005.04 75 14.66 3120 3430 3.75 / 25.25 2 3
4 13 545.32 18 15.21 1136 311 4.06 / 25.56 2 4
5 13 25.80 18 15.40 339 94 4.16 / 25.66 2 2
6 8 -0.12 165 15.35 291 737 4.89 / 26.39 2 2
7 14 -0.12 75 15.32 288 331 5.22 / 26.72 2 2
Average= 3.82
(KJ/cycle)

Cycle 5 GMT 31/ 1/2023 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 28 15.28 476 204 0.20 / 16.77 2 3
2 10 1043.88 3 15.14 1894 86 0.29 / 16.86 2 3
3 3 1060.76 2 15.21 1932 59 0.35 / 16.92 2 3
4 7 2009.92 75 14.65 3124 3432 3.78 / 20.35 2 3
5 13 557.48 18 15.20 1145 313 4.09 / 20.66 2 4
6 13 40.76 18 15.39 360 100 4.19 / 20.76 2 3
7 8 0.16 165 15.36 291 738 4.93 / 21.50 2 2
Average= 3.58
(KJ/cycle)

Cycle 4 GMT 21/ 1/2023 4: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 32 15.28 483 236 0.24 / 12.61 2 3
2 7 1522.64 74 14.83 2465 2705 2.94 / 15.31 2 3
3 13 305.16 18 15.29 771 212 3.15 / 15.52 2 4
4 8 0.24 165 15.35 284 719 3.87 / 16.24 2 3
5 14 0.24 75 15.33 283 325 4.20 / 16.57 2 4
Average= 3.31
(KJ/cycle)

Cycle 3 GMT 20/ 1/2023 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 32 15.29 477 233 0.23 / 8.70 2 3
2 3 1023.72 1 15.31 1863 29 0.26 / 8.73 2 3
3 7 1519.12 74 14.87 2459 2706 2.97 / 11.43 2 3
4 13 322.00 18 15.30 796 219 3.19 / 11.65 2 4
5 8 -0.04 165 15.36 283 717 3.90 / 12.37 2 2
Average= 3.09
(KJ/cycle)

Cycle 2 GMT 19/ 1/2023 5: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 31 15.33 475 226 0.23 / 4.78 2 3
2 10 1013.20 2 15.22 1826 56 0.28 / 4.84 2 3
3 7 1519.08 74 14.87 2457 2704 2.98 / 7.54 2 3
4 13 309.24 18 15.30 768 212 3.20 / 7.75 2 4
5 8 0.00 165 15.37 282 715 3.91 / 8.47 2 2
Average= 2.82
(KJ/cycle)

Cycle 1 GMT 18/ 1/2023 5:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 26 15.50 428 172 0.17 / 1.74 2 3
2 10 1020.24 4 15.22 1818 111 0.28 / 1.85 2 3
3 3 1059.52 2 15.25 1901 58 0.34 / 1.91 2 3
4 7 1002.16 74 15.08 1735 1936 2.28 / 3.84 2 4
5 8 -0.04 165 15.42 280 712 2.99 / 4.55 2 2
Average= 2.28
(KJ/cycle)

Cycle 0 GMT 17/ 1/2023 19:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 94.64 25 15.64 400 156 0.16 / 0.16 2 3
2 7 110.08 75 15.60 417 488 0.64 / 0.64 2 3
3 8 0.36 240 15.59 246 920 1.56 / 1.56 2 10
Average= 1.56
(KJ/cycle)