SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 32 | 15.09 | 442 | 213 | 0.21 / 289.76 | 2 | 3 |
2 | 7 | 2005.00 | 38 | 14.76 | 2861 | 1605 | 1.82 / 291.36 | 2 | 8 |
3 | 13 | 1462.24 | 18 | 14.84 | 2226 | 595 | 2.41 / 291.96 | 2 | 12 |
4 | 13 | 877.92 | 18 | 14.96 | 1491 | 401 | 2.81 / 292.36 | 2 | 12 |
5 | 13 | 433.28 | 18 | 15.08 | 911 | 247 | 3.06 / 292.61 | 2 | 13 |
6 | 13 | 15.96 | 18 | 15.18 | 321 | 88 | 3.15 / 292.69 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.14 | 300 | 749 | 3.90 / 293.44 | 2 | 18 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 32 | 15.08 | 445 | 215 | 0.21 / 285.83 | 2 | 3 |
2 | 7 | 2003.76 | 39 | 14.75 | 2855 | 1642 | 1.86 / 287.47 | 2 | 7 |
3 | 13 | 1416.60 | 18 | 14.83 | 2170 | 579 | 2.44 / 288.05 | 2 | 10 |
4 | 13 | 885.40 | 18 | 14.96 | 1502 | 404 | 2.84 / 288.45 | 2 | 12 |
5 | 13 | 442.40 | 18 | 15.07 | 933 | 253 | 3.09 / 288.71 | 2 | 13 |
6 | 13 | 17.84 | 18 | 15.18 | 330 | 90 | 3.18 / 288.80 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.14 | 300 | 749 | 3.93 / 289.54 | 2 | 17 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 32 | 15.11 | 442 | 214 | 0.21 / 281.95 | 2 | 3 |
2 | 7 | 2009.84 | 38 | 14.75 | 2865 | 1606 | 1.82 / 283.55 | 2 | 9 |
3 | 13 | 1345.24 | 18 | 14.85 | 2077 | 555 | 2.37 / 284.11 | 2 | 11 |
4 | 13 | 865.80 | 18 | 14.96 | 1482 | 399 | 2.77 / 284.51 | 2 | 13 |
5 | 13 | 458.04 | 18 | 15.07 | 954 | 259 | 3.03 / 284.77 | 2 | 13 |
6 | 13 | 22.56 | 18 | 15.19 | 339 | 93 | 3.13 / 284.86 | 2 | 11 |
7 | 8 | -0.08 | 165 | 15.14 | 301 | 752 | 3.88 / 285.61 | 2 | 10 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 32 | 15.12 | 450 | 218 | 0.22 / 278.15 | 2 | 3 |
2 | 7 | 2014.28 | 38 | 14.76 | 2876 | 1613 | 1.83 / 279.76 | 2 | 7 |
3 | 13 | 1425.76 | 18 | 14.85 | 2185 | 584 | 2.41 / 280.35 | 2 | 10 |
4 | 13 | 883.56 | 18 | 14.97 | 1499 | 404 | 2.82 / 280.75 | 2 | 13 |
5 | 13 | 397.84 | 18 | 15.11 | 868 | 236 | 3.05 / 280.99 | 2 | 12 |
6 | 8 | 0.16 | 165 | 15.17 | 298 | 746 | 3.80 / 281.73 | 2 | 16 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 32 | 15.12 | 423 | 205 | 0.20 / 274.39 | 2 | 3 |
2 | 7 | 2004.00 | 38 | 14.77 | 2855 | 1602 | 1.81 / 275.99 | 2 | 9 |
3 | 13 | 1338.16 | 18 | 14.89 | 2067 | 554 | 2.36 / 276.55 | 2 | 11 |
4 | 13 | 896.36 | 18 | 14.98 | 1518 | 409 | 2.77 / 276.95 | 2 | 12 |
5 | 13 | 389.80 | 18 | 15.13 | 853 | 232 | 3.00 / 277.19 | 2 | 13 |
6 | 8 | 0.08 | 165 | 15.18 | 298 | 746 | 3.75 / 277.93 | 2 | 13 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 32 | 15.13 | 448 | 217 | 0.22 / 270.63 | 2 | 4 |
2 | 7 | 2004.16 | 38 | 14.76 | 2850 | 1599 | 1.82 / 272.23 | 2 | 9 |
3 | 13 | 1377.48 | 18 | 14.86 | 2118 | 567 | 2.38 / 272.79 | 2 | 11 |
4 | 13 | 925.92 | 18 | 14.97 | 1550 | 418 | 2.80 / 273.21 | 2 | 12 |
5 | 13 | 389.04 | 18 | 15.11 | 855 | 233 | 3.03 / 273.44 | 2 | 12 |
6 | 8 | 0.04 | 165 | 15.18 | 296 | 741 | 3.77 / 274.18 | 2 | 13 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 32 | 15.12 | 441 | 213 | 0.21 / 266.82 | 2 | 3 |
2 | 7 | 2004.76 | 38 | 14.77 | 2849 | 1599 | 1.81 / 268.42 | 2 | 8 |
3 | 13 | 1368.00 | 18 | 14.88 | 2105 | 564 | 2.38 / 268.98 | 2 | 11 |
4 | 13 | 973.48 | 18 | 14.96 | 1608 | 433 | 2.81 / 269.41 | 2 | 12 |
5 | 13 | 456.64 | 18 | 15.10 | 939 | 255 | 3.06 / 269.67 | 2 | 13 |
6 | 8 | 0.24 | 165 | 15.19 | 296 | 742 | 3.81 / 270.41 | 2 | 21 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 32 | 15.13 | 438 | 212 | 0.21 / 262.91 | 2 | 3 |
2 | 7 | 2010.56 | 38 | 14.77 | 2859 | 1605 | 1.82 / 264.51 | 2 | 8 |
3 | 13 | 1500.64 | 18 | 14.85 | 2255 | 603 | 2.42 / 265.11 | 2 | 11 |
4 | 13 | 931.76 | 18 | 14.96 | 1553 | 418 | 2.84 / 265.53 | 2 | 12 |
5 | 13 | 423.60 | 18 | 15.12 | 896 | 244 | 3.08 / 265.78 | 2 | 13 |
6 | 13 | 27.92 | 18 | 15.21 | 337 | 92 | 3.17 / 265.87 | 2 | 10 |
7 | 8 | 0.04 | 165 | 15.18 | 294 | 736 | 3.91 / 266.60 | 2 | 18 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.56 | 32 | 15.13 | 447 | 216 | 0.22 / 259.15 | 2 | 4 |
2 | 7 | 2004.20 | 38 | 14.77 | 2853 | 1601 | 1.82 / 260.75 | 2 | 9 |
3 | 13 | 1439.20 | 18 | 14.87 | 2185 | 585 | 2.40 / 261.34 | 2 | 11 |
4 | 13 | 851.48 | 18 | 15.00 | 1447 | 391 | 2.79 / 261.73 | 2 | 13 |
5 | 13 | 367.28 | 18 | 15.15 | 814 | 222 | 3.02 / 261.95 | 2 | 12 |
6 | 8 | 0.24 | 165 | 15.19 | 297 | 744 | 3.76 / 262.69 | 2 | 17 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 32 | 15.15 | 424 | 206 | 0.21 / 255.35 | 2 | 3 |
2 | 7 | 2011.84 | 38 | 14.77 | 2862 | 1606 | 1.81 / 256.96 | 2 | 8 |
3 | 13 | 1361.40 | 18 | 14.90 | 2099 | 563 | 2.37 / 257.52 | 2 | 12 |
4 | 13 | 970.20 | 18 | 14.97 | 1606 | 433 | 2.81 / 257.95 | 2 | 12 |
5 | 13 | 398.80 | 18 | 15.13 | 866 | 236 | 3.04 / 258.19 | 2 | 13 |
6 | 8 | 0.08 | 165 | 15.18 | 298 | 746 | 3.79 / 258.93 | 2 | 19 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 32 | 15.14 | 442 | 214 | 0.21 / 251.57 | 2 | 3 |
2 | 7 | 2004.52 | 38 | 14.78 | 2855 | 1603 | 1.82 / 253.18 | 2 | 8 |
3 | 13 | 1387.64 | 18 | 14.89 | 2134 | 572 | 2.39 / 253.75 | 2 | 10 |
4 | 13 | 892.80 | 18 | 15.00 | 1514 | 409 | 2.80 / 254.16 | 2 | 12 |
5 | 13 | 394.20 | 18 | 15.15 | 857 | 234 | 3.03 / 254.39 | 2 | 14 |
6 | 8 | 0.08 | 165 | 15.20 | 301 | 755 | 3.79 / 255.14 | 2 | 11 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 32 | 15.15 | 436 | 211 | 0.21 / 247.80 | 2 | 3 |
2 | 7 | 2003.20 | 38 | 14.78 | 2854 | 1603 | 1.81 / 249.40 | 2 | 9 |
3 | 13 | 1404.00 | 18 | 14.89 | 2144 | 575 | 2.39 / 249.97 | 2 | 11 |
4 | 13 | 910.64 | 18 | 15.00 | 1533 | 414 | 2.80 / 250.39 | 2 | 13 |
5 | 13 | 370.24 | 18 | 15.16 | 826 | 225 | 3.03 / 250.61 | 2 | 13 |
6 | 8 | 0.04 | 165 | 15.21 | 297 | 745 | 3.77 / 251.36 | 2 | 19 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 32 | 15.14 | 444 | 215 | 0.22 / 244.04 | 2 | 3 |
2 | 7 | 2013.96 | 38 | 14.77 | 2868 | 1610 | 1.82 / 245.65 | 2 | 8 |
3 | 13 | 1336.32 | 18 | 14.91 | 2059 | 553 | 2.38 / 246.21 | 2 | 12 |
4 | 13 | 896.00 | 18 | 15.00 | 1513 | 409 | 2.79 / 246.61 | 2 | 12 |
5 | 13 | 352.68 | 18 | 15.16 | 806 | 220 | 3.01 / 246.83 | 2 | 12 |
6 | 8 | 0.20 | 165 | 15.20 | 299 | 750 | 3.76 / 247.58 | 2 | 14 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 32 | 15.15 | 439 | 213 | 0.21 / 240.29 | 2 | 3 |
2 | 7 | 2003.68 | 38 | 14.77 | 2845 | 1597 | 1.81 / 241.88 | 2 | 9 |
3 | 13 | 1358.92 | 18 | 14.90 | 2086 | 559 | 2.37 / 242.44 | 2 | 11 |
4 | 13 | 873.60 | 18 | 15.02 | 1473 | 398 | 2.77 / 242.84 | 2 | 13 |
5 | 13 | 341.80 | 18 | 15.16 | 783 | 214 | 2.98 / 243.06 | 2 | 13 |
6 | 8 | 0.08 | 165 | 15.20 | 308 | 772 | 3.75 / 243.83 | 2 | 21 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 32 | 15.15 | 444 | 215 | 0.22 / 236.49 | 2 | 4 |
2 | 7 | 2004.92 | 38 | 14.77 | 2845 | 1597 | 1.81 / 238.09 | 2 | 9 |
3 | 13 | 1408.64 | 18 | 14.89 | 2147 | 575 | 2.39 / 238.67 | 2 | 12 |
4 | 13 | 925.04 | 18 | 14.99 | 1541 | 416 | 2.80 / 239.08 | 2 | 12 |
5 | 13 | 417.12 | 18 | 15.14 | 889 | 242 | 3.05 / 239.33 | 2 | 13 |
6 | 8 | 0.04 | 165 | 15.20 | 299 | 750 | 3.80 / 240.08 | 2 | 17 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 32 | 15.15 | 452 | 219 | 0.22 / 232.76 | 2 | 4 |
2 | 7 | 2003.88 | 38 | 14.78 | 2842 | 1596 | 1.82 / 234.36 | 2 | 8 |
3 | 13 | 1435.76 | 18 | 14.89 | 2183 | 585 | 2.40 / 234.94 | 2 | 11 |
4 | 13 | 805.36 | 18 | 15.04 | 1394 | 377 | 2.78 / 235.32 | 2 | 11 |
5 | 13 | 342.44 | 18 | 15.16 | 792 | 216 | 2.99 / 235.53 | 2 | 12 |
6 | 8 | 0.12 | 165 | 15.20 | 297 | 745 | 3.74 / 236.28 | 2 | 17 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 32 | 15.16 | 426 | 207 | 0.21 / 228.98 | 2 | 3 |
2 | 7 | 2007.12 | 38 | 14.78 | 2853 | 1602 | 1.81 / 230.59 | 2 | 7 |
3 | 13 | 1412.44 | 18 | 14.89 | 2145 | 575 | 2.38 / 231.16 | 2 | 12 |
4 | 13 | 841.08 | 18 | 15.03 | 1435 | 388 | 2.77 / 231.55 | 2 | 13 |
5 | 13 | 396.64 | 18 | 15.16 | 861 | 235 | 3.01 / 231.79 | 2 | 12 |
6 | 8 | 0.12 | 165 | 15.21 | 301 | 755 | 3.76 / 232.54 | 2 | 14 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 32 | 15.17 | 445 | 216 | 0.22 / 225.28 | 2 | 3 |
2 | 7 | 2005.36 | 38 | 14.78 | 2851 | 1601 | 1.82 / 226.88 | 2 | 8 |
3 | 13 | 1377.88 | 18 | 14.91 | 2111 | 567 | 2.38 / 227.44 | 2 | 12 |
4 | 13 | 813.88 | 18 | 15.05 | 1397 | 378 | 2.76 / 227.82 | 2 | 11 |
5 | 13 | 339.04 | 18 | 15.17 | 781 | 213 | 2.98 / 228.03 | 2 | 14 |
6 | 8 | 0.16 | 165 | 15.22 | 296 | 743 | 3.72 / 228.78 | 2 | 19 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 32 | 15.17 | 446 | 217 | 0.22 / 221.54 | 2 | 4 |
2 | 7 | 2007.88 | 38 | 14.80 | 2857 | 1607 | 1.82 / 223.15 | 2 | 8 |
3 | 13 | 1331.08 | 18 | 14.93 | 2053 | 552 | 2.38 / 223.70 | 2 | 11 |
4 | 13 | 851.76 | 18 | 15.05 | 1463 | 396 | 2.77 / 224.09 | 2 | 13 |
5 | 13 | 360.00 | 18 | 15.18 | 812 | 222 | 2.99 / 224.32 | 2 | 12 |
6 | 8 | 0.16 | 165 | 15.22 | 296 | 743 | 3.74 / 225.06 | 2 | 15 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 32 | 15.19 | 436 | 212 | 0.21 / 217.81 | 2 | 3 |
2 | 7 | 2003.28 | 38 | 14.79 | 2848 | 1601 | 1.81 / 219.41 | 2 | 9 |
3 | 13 | 1377.12 | 18 | 14.91 | 2113 | 567 | 2.38 / 219.98 | 2 | 10 |
4 | 13 | 804.40 | 18 | 15.05 | 1393 | 377 | 2.76 / 220.36 | 2 | 13 |
5 | 13 | 374.68 | 18 | 15.17 | 831 | 227 | 2.98 / 220.58 | 2 | 14 |
6 | 8 | 0.08 | 165 | 15.22 | 295 | 741 | 3.72 / 221.32 | 2 | 13 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 32 | 15.18 | 429 | 208 | 0.21 / 213.89 | 2 | 3 |
2 | 7 | 2005.80 | 39 | 14.79 | 2845 | 1641 | 1.85 / 215.53 | 2 | 8 |
3 | 13 | 1456.56 | 18 | 14.90 | 2204 | 591 | 2.44 / 216.13 | 2 | 11 |
4 | 13 | 856.16 | 18 | 15.04 | 1470 | 398 | 2.84 / 216.52 | 2 | 13 |
5 | 13 | 406.80 | 18 | 15.18 | 880 | 240 | 3.08 / 216.76 | 2 | 13 |
6 | 13 | 24.28 | 18 | 15.25 | 333 | 91 | 3.17 / 216.85 | 2 | 12 |
7 | 8 | 0.12 | 165 | 15.22 | 296 | 743 | 3.91 / 217.60 | 2 | 9 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 32 | 15.18 | 439 | 213 | 0.21 / 209.99 | 2 | 3 |
2 | 7 | 2006.84 | 38 | 14.79 | 2859 | 1607 | 1.82 / 211.60 | 2 | 8 |
3 | 13 | 1385.88 | 18 | 14.92 | 2127 | 571 | 2.39 / 212.17 | 2 | 10 |
4 | 13 | 988.80 | 18 | 15.01 | 1625 | 439 | 2.83 / 212.61 | 2 | 13 |
5 | 13 | 376.12 | 18 | 15.18 | 840 | 230 | 3.06 / 212.84 | 2 | 14 |
6 | 13 | 15.80 | 18 | 15.28 | 326 | 90 | 3.15 / 212.93 | 2 | 13 |
7 | 8 | 0.12 | 165 | 15.23 | 300 | 754 | 3.90 / 213.68 | 2 | 12 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 32 | 15.17 | 439 | 213 | 0.21 / 206.10 | 2 | 3 |
2 | 7 | 2004.12 | 38 | 14.80 | 2854 | 1605 | 1.82 / 207.70 | 2 | 8 |
3 | 13 | 1473.48 | 18 | 14.91 | 2238 | 601 | 2.42 / 208.30 | 2 | 11 |
4 | 13 | 832.88 | 18 | 15.07 | 1433 | 389 | 2.81 / 208.69 | 2 | 13 |
5 | 13 | 398.56 | 18 | 15.19 | 873 | 239 | 3.05 / 208.93 | 2 | 13 |
6 | 13 | 18.76 | 18 | 15.28 | 334 | 92 | 3.14 / 209.02 | 2 | 6 |
7 | 8 | 0.00 | 165 | 15.22 | 302 | 758 | 3.90 / 209.78 | 2 | 20 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 32 | 15.19 | 447 | 217 | 0.22 / 202.16 | 2 | 3 |
2 | 7 | 2005.84 | 38 | 14.81 | 2850 | 1604 | 1.82 / 203.76 | 2 | 9 |
3 | 13 | 1494.92 | 18 | 14.90 | 2255 | 605 | 2.43 / 204.37 | 2 | 11 |
4 | 13 | 936.68 | 18 | 15.03 | 1561 | 422 | 2.85 / 204.79 | 2 | 12 |
5 | 13 | 429.36 | 18 | 15.17 | 916 | 250 | 3.10 / 205.04 | 2 | 13 |
6 | 13 | 34.52 | 18 | 15.27 | 349 | 96 | 3.19 / 205.14 | 2 | 7 |
7 | 8 | 0.20 | 165 | 15.22 | 298 | 748 | 3.94 / 205.88 | 2 | 18 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 32 | 15.19 | 418 | 203 | 0.20 / 198.28 | 2 | 3 |
2 | 7 | 2008.72 | 38 | 14.81 | 2851 | 1604 | 1.81 / 199.88 | 2 | 9 |
3 | 13 | 1410.80 | 18 | 14.93 | 2150 | 578 | 2.39 / 200.46 | 2 | 11 |
4 | 13 | 869.88 | 18 | 15.06 | 1484 | 402 | 2.79 / 200.86 | 2 | 13 |
5 | 13 | 331.44 | 18 | 15.22 | 769 | 211 | 3.00 / 201.07 | 2 | 13 |
6 | 13 | 35.04 | 18 | 15.28 | 374 | 103 | 3.10 / 201.18 | 2 | 8 |
7 | 8 | -0.04 | 165 | 15.24 | 304 | 764 | 3.87 / 201.94 | 2 | 12 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 32 | 15.18 | 444 | 216 | 0.22 / 194.37 | 2 | 3 |
2 | 7 | 2005.72 | 38 | 14.82 | 2855 | 1608 | 1.82 / 195.98 | 2 | 8 |
3 | 13 | 1435.08 | 18 | 14.94 | 2189 | 589 | 2.41 / 196.57 | 2 | 10 |
4 | 13 | 941.04 | 18 | 15.04 | 1564 | 423 | 2.84 / 196.99 | 2 | 12 |
5 | 13 | 424.48 | 18 | 15.19 | 901 | 246 | 3.08 / 197.24 | 2 | 14 |
6 | 13 | 31.72 | 18 | 15.28 | 349 | 96 | 3.18 / 197.33 | 2 | 7 |
7 | 8 | 0.08 | 165 | 15.24 | 296 | 744 | 3.92 / 198.08 | 2 | 18 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 32 | 15.18 | 457 | 222 | 0.22 / 190.49 | 2 | 3 |
2 | 7 | 2012.48 | 38 | 14.82 | 2866 | 1614 | 1.84 / 192.11 | 2 | 8 |
3 | 13 | 1365.28 | 18 | 14.95 | 2098 | 565 | 2.40 / 192.67 | 2 | 12 |
4 | 13 | 877.28 | 18 | 15.07 | 1485 | 403 | 2.80 / 193.07 | 2 | 12 |
5 | 13 | 381.60 | 18 | 15.20 | 844 | 231 | 3.03 / 193.30 | 2 | 13 |
6 | 13 | 34.72 | 18 | 15.28 | 354 | 97 | 3.13 / 193.40 | 2 | 8 |
7 | 8 | 0.00 | 165 | 15.25 | 299 | 752 | 3.88 / 194.15 | 2 | 13 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 32 | 15.20 | 440 | 214 | 0.21 / 186.61 | 2 | 3 |
2 | 7 | 2004.76 | 38 | 14.82 | 2851 | 1606 | 1.82 / 188.22 | 2 | 8 |
3 | 13 | 1365.68 | 18 | 14.95 | 2102 | 566 | 2.39 / 188.78 | 2 | 12 |
4 | 13 | 832.92 | 18 | 15.09 | 1431 | 389 | 2.77 / 189.17 | 2 | 12 |
5 | 13 | 388.08 | 18 | 15.21 | 856 | 234 | 3.01 / 189.41 | 2 | 13 |
6 | 13 | 35.84 | 18 | 15.29 | 360 | 99 | 3.11 / 189.51 | 2 | 10 |
7 | 8 | 0.04 | 165 | 15.24 | 304 | 764 | 3.87 / 190.27 | 2 | 16 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 32 | 15.19 | 420 | 204 | 0.20 / 182.79 | 2 | 3 |
2 | 7 | 2004.48 | 38 | 14.82 | 2844 | 1602 | 1.81 / 184.39 | 2 | 11 |
3 | 13 | 1391.56 | 18 | 14.94 | 2130 | 573 | 2.38 / 184.97 | 2 | 10 |
4 | 13 | 792.92 | 18 | 15.09 | 1374 | 373 | 2.75 / 185.34 | 2 | 13 |
5 | 13 | 356.40 | 18 | 15.21 | 805 | 220 | 2.97 / 185.56 | 2 | 12 |
6 | 13 | 28.24 | 18 | 15.29 | 337 | 93 | 3.06 / 185.65 | 2 | 10 |
7 | 8 | 0.12 | 165 | 15.25 | 296 | 745 | 3.81 / 186.40 | 2 | 12 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 31 | 15.20 | 434 | 205 | 0.20 / 178.95 | 2 | 3 |
2 | 7 | 2003.64 | 38 | 14.82 | 2847 | 1603 | 1.81 / 180.55 | 2 | 9 |
3 | 13 | 1404.36 | 18 | 14.93 | 2146 | 577 | 2.38 / 181.13 | 2 | 11 |
4 | 13 | 853.24 | 18 | 15.07 | 1454 | 394 | 2.78 / 181.52 | 2 | 12 |
5 | 13 | 372.68 | 18 | 15.21 | 825 | 226 | 3.00 / 181.75 | 2 | 13 |
6 | 13 | 30.04 | 18 | 15.29 | 346 | 95 | 3.10 / 181.84 | 2 | 7 |
7 | 8 | 0.00 | 165 | 15.24 | 296 | 744 | 3.84 / 182.59 | 2 | 15 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 31 | 15.21 | 450 | 212 | 0.21 / 175.13 | 2 | 3 |
2 | 7 | 2006.00 | 38 | 14.83 | 2845 | 1603 | 1.82 / 176.73 | 2 | 8 |
3 | 13 | 1355.40 | 18 | 14.97 | 2083 | 561 | 2.38 / 177.29 | 2 | 11 |
4 | 13 | 844.24 | 18 | 15.08 | 1440 | 391 | 2.77 / 177.68 | 2 | 13 |
5 | 13 | 347.24 | 18 | 15.22 | 793 | 217 | 2.98 / 177.90 | 2 | 13 |
6 | 13 | 36.04 | 18 | 15.28 | 358 | 98 | 3.08 / 178.00 | 2 | 8 |
7 | 8 | 0.08 | 165 | 15.25 | 296 | 745 | 3.83 / 178.74 | 2 | 14 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 31 | 15.20 | 450 | 212 | 0.21 / 171.25 | 2 | 3 |
2 | 7 | 2007.08 | 38 | 14.83 | 2854 | 1608 | 1.82 / 172.86 | 2 | 10 |
3 | 13 | 1395.84 | 18 | 14.96 | 2141 | 577 | 2.40 / 173.44 | 2 | 11 |
4 | 13 | 846.28 | 18 | 15.09 | 1450 | 394 | 2.79 / 173.83 | 2 | 12 |
5 | 13 | 362.08 | 18 | 15.24 | 819 | 225 | 3.02 / 174.06 | 2 | 13 |
6 | 13 | 27.08 | 18 | 15.31 | 345 | 95 | 3.11 / 174.15 | 2 | 8 |
7 | 8 | 0.08 | 165 | 15.27 | 303 | 763 | 3.87 / 174.92 | 2 | 14 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 31 | 15.20 | 439 | 207 | 0.21 / 167.40 | 2 | 3 |
2 | 7 | 2004.28 | 38 | 14.83 | 2841 | 1601 | 1.81 / 169.00 | 2 | 8 |
3 | 13 | 1398.48 | 18 | 14.96 | 2137 | 575 | 2.38 / 169.57 | 2 | 12 |
4 | 13 | 859.44 | 18 | 15.09 | 1463 | 397 | 2.78 / 169.97 | 2 | 13 |
5 | 13 | 339.04 | 18 | 15.24 | 783 | 215 | 3.00 / 170.19 | 2 | 13 |
6 | 13 | 36.36 | 18 | 15.30 | 359 | 99 | 3.09 / 170.28 | 2 | 8 |
7 | 8 | 0.04 | 165 | 15.26 | 301 | 758 | 3.85 / 171.04 | 2 | 17 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 31 | 15.20 | 470 | 221 | 0.22 / 163.54 | 2 | 3 |
2 | 7 | 2003.20 | 38 | 14.85 | 2838 | 1601 | 1.82 / 165.14 | 2 | 8 |
3 | 13 | 1330.76 | 18 | 14.99 | 2055 | 554 | 2.38 / 165.69 | 2 | 10 |
4 | 13 | 853.52 | 18 | 15.10 | 1453 | 395 | 2.77 / 166.09 | 2 | 12 |
5 | 13 | 393.32 | 18 | 15.23 | 858 | 235 | 3.01 / 166.32 | 2 | 14 |
6 | 13 | 31.08 | 18 | 15.31 | 353 | 97 | 3.10 / 166.42 | 2 | 9 |
7 | 8 | 0.08 | 165 | 15.26 | 305 | 768 | 3.87 / 167.19 | 2 | 17 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 31 | 15.21 | 432 | 204 | 0.20 / 159.68 | 2 | 3 |
2 | 7 | 2003.48 | 39 | 14.83 | 2858 | 1653 | 1.86 / 161.33 | 2 | 8 |
3 | 13 | 1361.60 | 18 | 14.97 | 2093 | 564 | 2.42 / 161.90 | 2 | 11 |
4 | 13 | 869.12 | 18 | 15.08 | 1481 | 402 | 2.82 / 162.30 | 2 | 13 |
5 | 13 | 380.00 | 18 | 15.23 | 841 | 231 | 3.05 / 162.53 | 2 | 13 |
6 | 8 | 0.04 | 165 | 15.26 | 313 | 788 | 3.84 / 163.32 | 2 | 12 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 31 | 15.21 | 443 | 209 | 0.21 / 155.79 | 2 | 3 |
2 | 7 | 2004.64 | 38 | 14.84 | 2854 | 1609 | 1.82 / 157.39 | 2 | 8 |
3 | 13 | 1437.68 | 18 | 14.95 | 2189 | 589 | 2.41 / 157.98 | 2 | 10 |
4 | 13 | 879.92 | 18 | 15.09 | 1487 | 404 | 2.81 / 158.39 | 2 | 12 |
5 | 13 | 386.84 | 18 | 15.23 | 852 | 234 | 3.04 / 158.62 | 2 | 13 |
6 | 13 | 15.96 | 18 | 15.31 | 329 | 91 | 3.14 / 158.71 | 2 | 9 |
7 | 8 | 0.08 | 165 | 15.27 | 303 | 763 | 3.90 / 159.48 | 2 | 16 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 31 | 15.23 | 451 | 213 | 0.21 / 151.90 | 2 | 3 |
2 | 7 | 2004.84 | 38 | 14.85 | 2847 | 1607 | 1.82 / 153.50 | 2 | 10 |
3 | 13 | 1409.20 | 18 | 14.98 | 2145 | 578 | 2.40 / 154.08 | 2 | 12 |
4 | 13 | 873.92 | 18 | 15.11 | 1479 | 402 | 2.80 / 154.49 | 2 | 12 |
5 | 13 | 422.32 | 18 | 15.22 | 893 | 245 | 3.04 / 154.73 | 2 | 13 |
6 | 13 | 25.08 | 18 | 15.31 | 338 | 93 | 3.14 / 154.82 | 2 | 9 |
7 | 8 | 0.00 | 165 | 15.27 | 299 | 753 | 3.89 / 155.58 | 2 | 16 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 31 | 15.23 | 449 | 212 | 0.21 / 148.09 | 2 | 3 |
2 | 7 | 2005.24 | 39 | 14.85 | 2839 | 1644 | 1.86 / 149.73 | 2 | 9 |
3 | 13 | 1377.28 | 18 | 14.98 | 2114 | 570 | 2.43 / 150.30 | 2 | 12 |
4 | 13 | 849.28 | 18 | 15.08 | 1454 | 395 | 2.82 / 150.70 | 2 | 13 |
5 | 13 | 396.24 | 18 | 15.22 | 860 | 236 | 3.06 / 150.93 | 2 | 13 |
6 | 8 | 0.04 | 165 | 15.28 | 298 | 751 | 3.81 / 151.69 | 2 | 15 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 31 | 15.22 | 456 | 215 | 0.22 / 144.29 | 2 | 3 |
2 | 7 | 2012.40 | 38 | 14.83 | 2853 | 1608 | 1.82 / 145.90 | 2 | 9 |
3 | 13 | 1474.12 | 18 | 14.95 | 2217 | 597 | 2.42 / 146.50 | 2 | 10 |
4 | 13 | 872.72 | 18 | 15.09 | 1475 | 401 | 2.82 / 146.90 | 2 | 13 |
5 | 13 | 382.32 | 18 | 15.23 | 841 | 231 | 3.05 / 147.13 | 2 | 13 |
6 | 8 | 0.16 | 165 | 15.27 | 298 | 751 | 3.80 / 147.88 | 2 | 14 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 31 | 15.24 | 421 | 199 | 0.20 / 140.41 | 2 | 3 |
2 | 7 | 2010.88 | 39 | 14.84 | 2858 | 1654 | 1.85 / 142.07 | 2 | 9 |
3 | 13 | 1466.00 | 18 | 14.96 | 2216 | 597 | 2.45 / 142.66 | 2 | 10 |
4 | 13 | 861.88 | 18 | 15.10 | 1463 | 398 | 2.85 / 143.06 | 2 | 12 |
5 | 13 | 404.24 | 18 | 15.23 | 874 | 240 | 3.09 / 143.30 | 2 | 14 |
6 | 8 | 0.28 | 165 | 15.28 | 307 | 774 | 3.86 / 144.08 | 2 | 12 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 31 | 15.23 | 447 | 211 | 0.21 / 136.70 | 2 | 3 |
2 | 7 | 2011.36 | 38 | 14.84 | 2852 | 1608 | 1.82 / 138.30 | 2 | 7 |
3 | 13 | 1361.12 | 18 | 14.98 | 2094 | 565 | 2.38 / 138.87 | 2 | 11 |
4 | 13 | 795.60 | 18 | 15.12 | 1391 | 379 | 2.76 / 139.25 | 2 | 13 |
5 | 13 | 360.92 | 18 | 15.24 | 815 | 224 | 2.99 / 139.47 | 2 | 14 |
6 | 8 | 0.16 | 165 | 15.28 | 295 | 744 | 3.73 / 140.22 | 2 | 15 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 31 | 15.25 | 432 | 204 | 0.20 / 132.95 | 2 | 3 |
2 | 7 | 2004.00 | 38 | 14.84 | 2853 | 1609 | 1.81 / 134.56 | 2 | 9 |
3 | 13 | 1357.32 | 18 | 14.99 | 2083 | 562 | 2.38 / 135.12 | 2 | 12 |
4 | 13 | 833.40 | 18 | 15.11 | 1430 | 389 | 2.76 / 135.51 | 2 | 14 |
5 | 13 | 382.44 | 18 | 15.24 | 845 | 232 | 3.00 / 135.74 | 2 | 13 |
6 | 8 | 0.04 | 165 | 15.29 | 295 | 744 | 3.74 / 136.49 | 2 | 14 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 31 | 15.25 | 447 | 211 | 0.21 / 129.21 | 2 | 3 |
2 | 7 | 2004.56 | 38 | 14.86 | 2850 | 1609 | 1.82 / 130.82 | 2 | 9 |
3 | 13 | 1407.48 | 18 | 14.99 | 2144 | 578 | 2.40 / 131.40 | 2 | 12 |
4 | 13 | 777.36 | 18 | 15.14 | 1357 | 370 | 2.77 / 131.77 | 2 | 13 |
5 | 13 | 353.84 | 18 | 15.27 | 810 | 223 | 2.99 / 131.99 | 2 | 13 |
6 | 8 | 0.16 | 165 | 15.30 | 299 | 755 | 3.75 / 132.75 | 2 | 18 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 31 | 15.28 | 447 | 212 | 0.21 / 125.39 | 2 | 3 |
2 | 7 | 2006.52 | 39 | 14.84 | 2856 | 1653 | 1.86 / 127.04 | 2 | 9 |
3 | 13 | 1366.80 | 18 | 15.01 | 2099 | 567 | 2.43 / 127.61 | 2 | 12 |
4 | 13 | 840.88 | 18 | 15.13 | 1441 | 392 | 2.82 / 128.00 | 2 | 13 |
5 | 13 | 379.72 | 18 | 15.25 | 843 | 231 | 3.06 / 128.23 | 2 | 14 |
6 | 8 | 0.24 | 165 | 15.30 | 303 | 765 | 3.82 / 129.00 | 2 | 13 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 31 | 15.25 | 441 | 208 | 0.21 / 121.59 | 2 | 3 |
2 | 7 | 2004.16 | 38 | 14.90 | 2854 | 1616 | 1.82 / 123.20 | 2 | 8 |
3 | 13 | 1365.44 | 18 | 15.03 | 2102 | 569 | 2.39 / 123.77 | 2 | 12 |
4 | 13 | 836.84 | 18 | 15.16 | 1436 | 392 | 2.78 / 124.16 | 2 | 13 |
5 | 13 | 438.76 | 18 | 15.26 | 920 | 253 | 3.04 / 124.41 | 2 | 14 |
6 | 8 | 0.08 | 165 | 15.32 | 302 | 763 | 3.80 / 125.18 | 2 | 14 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 31 | 15.25 | 455 | 215 | 0.22 / 117.78 | 2 | 3 |
2 | 7 | 2004.00 | 38 | 14.87 | 2850 | 1610 | 1.83 / 119.39 | 2 | 8 |
3 | 13 | 1362.00 | 18 | 15.01 | 2092 | 565 | 2.39 / 119.95 | 2 | 12 |
4 | 13 | 957.56 | 18 | 15.09 | 1588 | 431 | 2.82 / 120.38 | 2 | 12 |
5 | 13 | 387.28 | 18 | 15.24 | 853 | 234 | 3.06 / 120.62 | 2 | 14 |
6 | 8 | 0.16 | 165 | 15.29 | 301 | 759 | 3.82 / 121.38 | 2 | 15 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 31 | 15.26 | 451 | 213 | 0.21 / 113.96 | 2 | 3 |
2 | 7 | 2012.16 | 38 | 14.86 | 2856 | 1613 | 1.83 / 115.57 | 2 | 8 |
3 | 13 | 1445.64 | 18 | 14.99 | 2199 | 593 | 2.42 / 116.16 | 2 | 11 |
4 | 13 | 821.84 | 18 | 15.13 | 1419 | 386 | 2.81 / 116.55 | 2 | 13 |
5 | 13 | 380.04 | 18 | 15.25 | 852 | 234 | 3.04 / 116.78 | 2 | 14 |
6 | 8 | 0.16 | 165 | 15.30 | 308 | 778 | 3.82 / 117.56 | 2 | 13 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 31 | 15.27 | 441 | 209 | 0.21 / 110.13 | 2 | 3 |
2 | 7 | 2003.24 | 39 | 14.88 | 2845 | 1651 | 1.86 / 111.79 | 2 | 9 |
3 | 13 | 1361.08 | 18 | 15.02 | 2099 | 567 | 2.43 / 112.35 | 2 | 12 |
4 | 13 | 791.52 | 18 | 15.15 | 1375 | 375 | 2.80 / 112.73 | 2 | 13 |
5 | 13 | 401.28 | 18 | 15.25 | 878 | 241 | 3.04 / 112.97 | 2 | 14 |
6 | 8 | 0.04 | 165 | 15.30 | 307 | 775 | 3.82 / 113.74 | 2 | 14 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 31 | 15.26 | 450 | 213 | 0.21 / 106.39 | 2 | 3 |
2 | 7 | 2002.76 | 38 | 14.89 | 2842 | 1608 | 1.82 / 108.00 | 2 | 9 |
3 | 13 | 1328.32 | 18 | 15.04 | 2052 | 556 | 2.38 / 108.55 | 2 | 12 |
4 | 13 | 856.44 | 18 | 15.13 | 1459 | 397 | 2.77 / 108.95 | 2 | 13 |
5 | 13 | 358.28 | 18 | 15.27 | 817 | 225 | 3.00 / 109.18 | 2 | 13 |
6 | 8 | 0.12 | 165 | 15.31 | 297 | 750 | 3.75 / 109.93 | 2 | 14 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 31 | 15.23 | 449 | 212 | 0.21 / 102.63 | 2 | 3 |
2 | 7 | 2008.52 | 38 | 14.88 | 2839 | 1605 | 1.82 / 104.23 | 2 | 9 |
3 | 13 | 1409.32 | 18 | 15.01 | 2141 | 578 | 2.40 / 104.81 | 2 | 11 |
4 | 13 | 813.92 | 18 | 15.14 | 1397 | 381 | 2.78 / 105.19 | 2 | 13 |
5 | 13 | 367.08 | 18 | 15.26 | 831 | 228 | 3.00 / 105.42 | 2 | 14 |
6 | 8 | 0.08 | 165 | 15.31 | 300 | 758 | 3.76 / 106.18 | 2 | 14 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 31 | 15.26 | 441 | 209 | 0.21 / 98.83 | 2 | 3 |
2 | 7 | 2009.56 | 38 | 14.87 | 2854 | 1613 | 1.82 / 100.44 | 2 | 9 |
3 | 13 | 1404.24 | 18 | 15.01 | 2144 | 579 | 2.40 / 101.02 | 2 | 11 |
4 | 13 | 817.00 | 18 | 15.14 | 1412 | 385 | 2.79 / 101.41 | 2 | 13 |
5 | 13 | 379.80 | 18 | 15.26 | 846 | 232 | 3.02 / 101.64 | 2 | 14 |
6 | 8 | 0.12 | 165 | 15.30 | 307 | 775 | 3.79 / 102.41 | 2 | 15 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 31 | 15.28 | 446 | 211 | 0.21 / 95.06 | 2 | 3 |
2 | 7 | 2012.08 | 38 | 14.88 | 2852 | 1613 | 1.82 / 96.68 | 2 | 9 |
3 | 13 | 1401.08 | 18 | 15.01 | 2132 | 576 | 2.40 / 97.25 | 2 | 11 |
4 | 13 | 856.44 | 18 | 15.14 | 1460 | 398 | 2.80 / 97.65 | 2 | 13 |
5 | 13 | 329.12 | 18 | 15.29 | 775 | 213 | 3.01 / 97.86 | 2 | 13 |
6 | 8 | 0.16 | 165 | 15.32 | 300 | 758 | 3.77 / 98.62 | 2 | 14 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 31 | 15.28 | 445 | 211 | 0.21 / 91.28 | 2 | 3 |
2 | 7 | 2007.36 | 38 | 14.89 | 2847 | 1611 | 1.82 / 92.89 | 2 | 9 |
3 | 13 | 1343.56 | 18 | 15.04 | 2072 | 561 | 2.38 / 93.45 | 2 | 12 |
4 | 13 | 906.84 | 18 | 15.14 | 1524 | 415 | 2.80 / 93.87 | 2 | 13 |
5 | 13 | 355.12 | 18 | 15.28 | 812 | 223 | 3.02 / 94.09 | 2 | 14 |
6 | 8 | 0.12 | 165 | 15.31 | 301 | 760 | 3.78 / 94.85 | 2 | 14 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 31 | 15.28 | 436 | 207 | 0.21 / 87.51 | 2 | 3 |
2 | 7 | 2011.36 | 39 | 14.90 | 2844 | 1653 | 1.86 / 89.17 | 2 | 9 |
3 | 13 | 1286.52 | 18 | 15.06 | 1998 | 542 | 2.40 / 89.71 | 2 | 11 |
4 | 13 | 853.36 | 18 | 15.15 | 1448 | 395 | 2.80 / 90.10 | 2 | 13 |
5 | 13 | 357.84 | 18 | 15.29 | 807 | 222 | 3.02 / 90.32 | 2 | 14 |
6 | 8 | 0.04 | 165 | 15.33 | 295 | 746 | 3.76 / 91.07 | 2 | 16 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 31 | 15.28 | 425 | 201 | 0.20 / 83.76 | 2 | 3 |
2 | 7 | 2005.52 | 38 | 14.89 | 2838 | 1606 | 1.81 / 85.37 | 2 | 9 |
3 | 13 | 1369.48 | 18 | 15.03 | 2095 | 567 | 2.37 / 85.94 | 2 | 12 |
4 | 13 | 874.48 | 18 | 15.14 | 1470 | 401 | 2.77 / 86.34 | 2 | 13 |
5 | 13 | 349.92 | 18 | 15.28 | 802 | 221 | 3.00 / 86.56 | 2 | 13 |
6 | 8 | 0.28 | 165 | 15.32 | 297 | 751 | 3.75 / 87.31 | 2 | 16 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 31 | 15.27 | 428 | 203 | 0.20 / 80.06 | 2 | 3 |
2 | 7 | 2009.60 | 38 | 14.90 | 2839 | 1607 | 1.81 / 81.67 | 2 | 10 |
3 | 13 | 1401.36 | 18 | 15.03 | 2108 | 570 | 2.38 / 82.24 | 2 | 12 |
4 | 13 | 861.24 | 18 | 15.16 | 1435 | 392 | 2.77 / 82.63 | 2 | 13 |
5 | 13 | 329.56 | 18 | 15.29 | 750 | 206 | 2.98 / 82.84 | 2 | 13 |
6 | 8 | 0.28 | 165 | 15.34 | 285 | 721 | 3.70 / 83.56 | 2 | 13 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 31 | 15.27 | 407 | 193 | 0.19 / 76.40 | 2 | 3 |
2 | 7 | 2006.44 | 38 | 14.91 | 2837 | 1607 | 1.80 / 78.01 | 2 | 8 |
3 | 13 | 1344.92 | 18 | 15.05 | 2042 | 553 | 2.35 / 78.56 | 2 | 11 |
4 | 13 | 775.36 | 18 | 15.18 | 1328 | 363 | 2.72 / 78.92 | 2 | 13 |
5 | 13 | 380.84 | 18 | 15.29 | 824 | 227 | 2.94 / 79.15 | 2 | 14 |
6 | 8 | 0.08 | 165 | 15.32 | 282 | 713 | 3.66 / 79.86 | 2 | 15 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.84 | 31 | 15.29 | 417 | 198 | 0.20 / 72.58 | 2 | 3 |
2 | 7 | 2011.80 | 38 | 14.92 | 2840 | 1610 | 1.81 / 74.19 | 2 | 9 |
3 | 13 | 1429.80 | 18 | 15.04 | 2145 | 581 | 2.39 / 74.77 | 2 | 11 |
4 | 13 | 927.16 | 18 | 15.15 | 1525 | 416 | 2.80 / 75.19 | 2 | 14 |
5 | 13 | 369.36 | 18 | 15.30 | 806 | 222 | 3.03 / 75.41 | 2 | 14 |
6 | 13 | 11.08 | 18 | 15.37 | 299 | 83 | 3.11 / 75.50 | 2 | 9 |
7 | 8 | 0.00 | 165 | 15.32 | 281 | 710 | 3.82 / 76.21 | 2 | 13 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 31 | 15.28 | 400 | 189 | 0.19 / 68.86 | 2 | 3 |
2 | 7 | 2003.92 | 38 | 14.91 | 2825 | 1601 | 1.79 / 70.46 | 2 | 9 |
3 | 13 | 1446.88 | 18 | 15.02 | 2162 | 585 | 2.37 / 71.05 | 2 | 11 |
4 | 13 | 886.44 | 18 | 15.15 | 1479 | 403 | 2.78 / 71.45 | 2 | 13 |
5 | 13 | 374.68 | 18 | 15.29 | 814 | 224 | 3.00 / 71.68 | 2 | 14 |
6 | 8 | 0.24 | 165 | 15.33 | 281 | 711 | 3.71 / 72.39 | 2 | 15 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.92 | 31 | 15.30 | 420 | 199 | 0.20 / 65.19 | 2 | 3 |
2 | 7 | 2004.08 | 39 | 14.94 | 2829 | 1648 | 1.85 / 66.83 | 2 | 10 |
3 | 13 | 1292.00 | 18 | 15.08 | 1982 | 538 | 2.39 / 67.37 | 2 | 13 |
4 | 13 | 818.80 | 18 | 15.18 | 1384 | 378 | 2.76 / 67.75 | 2 | 14 |
5 | 13 | 345.36 | 18 | 15.30 | 771 | 212 | 2.98 / 67.96 | 2 | 14 |
6 | 8 | 0.04 | 165 | 15.34 | 281 | 711 | 3.69 / 68.67 | 2 | 16 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 31 | 15.27 | 402 | 190 | 0.19 / 61.54 | 2 | 3 |
2 | 7 | 2008.12 | 38 | 14.91 | 2826 | 1601 | 1.79 / 63.14 | 2 | 11 |
3 | 13 | 1313.88 | 18 | 15.07 | 2001 | 543 | 2.33 / 63.68 | 2 | 13 |
4 | 13 | 868.24 | 18 | 15.16 | 1444 | 394 | 2.73 / 64.08 | 2 | 14 |
5 | 13 | 324.48 | 18 | 15.31 | 740 | 204 | 2.93 / 64.28 | 2 | 14 |
6 | 8 | 0.04 | 165 | 15.34 | 279 | 706 | 3.64 / 64.99 | 2 | 13 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 31 | 15.26 | 406 | 192 | 0.19 / 57.90 | 2 | 3 |
2 | 7 | 2012.28 | 38 | 14.92 | 2835 | 1607 | 1.80 / 59.51 | 2 | 9 |
3 | 13 | 1351.16 | 18 | 15.06 | 2046 | 555 | 2.35 / 60.06 | 2 | 12 |
4 | 13 | 814.04 | 18 | 15.18 | 1374 | 375 | 2.73 / 60.44 | 2 | 14 |
5 | 13 | 324.76 | 18 | 15.32 | 738 | 204 | 2.93 / 60.64 | 2 | 14 |
6 | 8 | 0.28 | 165 | 15.33 | 280 | 708 | 3.64 / 61.35 | 2 | 16 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 31 | 15.28 | 410 | 194 | 0.19 / 54.16 | 2 | 3 |
2 | 7 | 2005.04 | 38 | 14.92 | 2826 | 1602 | 1.80 / 55.76 | 2 | 10 |
3 | 13 | 1341.56 | 18 | 15.07 | 2038 | 553 | 2.35 / 56.31 | 2 | 12 |
4 | 13 | 840.40 | 18 | 15.18 | 1412 | 386 | 2.74 / 56.70 | 2 | 15 |
5 | 13 | 336.04 | 18 | 15.32 | 761 | 210 | 2.94 / 56.91 | 2 | 14 |
6 | 13 | 16.40 | 18 | 15.37 | 309 | 85 | 3.03 / 56.99 | 2 | 10 |
7 | 8 | 0.04 | 165 | 15.32 | 282 | 713 | 3.74 / 57.71 | 2 | 16 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 31 | 15.28 | 423 | 200 | 0.20 / 50.41 | 2 | 3 |
2 | 7 | 2011.24 | 38 | 14.92 | 2841 | 1611 | 1.81 / 52.02 | 2 | 8 |
3 | 13 | 1329.00 | 18 | 15.08 | 2022 | 549 | 2.36 / 52.57 | 2 | 13 |
4 | 13 | 799.80 | 18 | 15.19 | 1358 | 371 | 2.73 / 52.94 | 2 | 13 |
5 | 13 | 354.32 | 18 | 15.31 | 781 | 215 | 2.95 / 53.15 | 2 | 14 |
6 | 13 | 37.92 | 18 | 15.37 | 342 | 95 | 3.04 / 53.25 | 2 | 10 |
7 | 8 | 0.08 | 165 | 15.33 | 283 | 716 | 3.76 / 53.96 | 2 | 17 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 31 | 15.28 | 425 | 201 | 0.20 / 46.59 | 2 | 3 |
2 | 7 | 2010.04 | 39 | 14.93 | 2836 | 1651 | 1.85 / 48.24 | 2 | 10 |
3 | 13 | 1393.52 | 18 | 15.06 | 2098 | 569 | 2.42 / 48.81 | 2 | 11 |
4 | 13 | 780.00 | 18 | 15.20 | 1331 | 364 | 2.79 / 49.17 | 2 | 12 |
5 | 13 | 393.52 | 18 | 15.31 | 834 | 230 | 3.02 / 49.40 | 2 | 14 |
6 | 13 | 34.16 | 18 | 15.37 | 337 | 93 | 3.11 / 49.49 | 2 | 10 |
7 | 8 | 0.12 | 165 | 15.34 | 282 | 714 | 3.82 / 50.21 | 2 | 15 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 31 | 15.31 | 426 | 202 | 0.20 / 42.83 | 2 | 3 |
2 | 7 | 2010.44 | 38 | 14.94 | 2836 | 1610 | 1.81 / 44.44 | 2 | 11 |
3 | 13 | 1294.64 | 18 | 15.09 | 1986 | 539 | 2.35 / 44.98 | 2 | 14 |
4 | 13 | 855.20 | 18 | 15.18 | 1434 | 392 | 2.74 / 45.38 | 2 | 13 |
5 | 13 | 353.48 | 18 | 15.30 | 782 | 215 | 2.96 / 45.59 | 2 | 13 |
6 | 13 | 23.36 | 18 | 15.37 | 315 | 87 | 3.05 / 45.68 | 2 | 9 |
7 | 8 | 0.00 | 165 | 15.34 | 279 | 706 | 3.75 / 46.38 | 2 | 16 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 31 | 15.29 | 423 | 200 | 0.20 / 39.02 | 2 | 3 |
2 | 7 | 2006.92 | 38 | 14.95 | 2823 | 1604 | 1.80 / 40.63 | 2 | 9 |
3 | 13 | 1437.20 | 18 | 15.06 | 2152 | 583 | 2.39 / 41.21 | 2 | 11 |
4 | 13 | 882.72 | 18 | 15.18 | 1461 | 399 | 2.79 / 41.61 | 2 | 13 |
5 | 13 | 370.40 | 18 | 15.31 | 802 | 221 | 3.01 / 41.83 | 2 | 14 |
6 | 13 | 25.60 | 18 | 15.39 | 321 | 89 | 3.10 / 41.92 | 2 | 9 |
7 | 8 | 0.08 | 165 | 15.35 | 281 | 712 | 3.81 / 42.63 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 30 | 15.31 | 403 | 185 | 0.19 / 35.19 | 2 | 3 |
2 | 7 | 2004.64 | 38 | 14.94 | 2818 | 1600 | 1.78 / 36.79 | 2 | 9 |
3 | 13 | 1426.92 | 18 | 15.07 | 2136 | 579 | 2.36 / 37.37 | 2 | 13 |
4 | 13 | 900.36 | 18 | 15.17 | 1483 | 405 | 2.77 / 37.78 | 2 | 13 |
5 | 13 | 435.00 | 18 | 15.29 | 894 | 246 | 3.02 / 38.02 | 2 | 14 |
6 | 13 | 29.52 | 18 | 15.38 | 325 | 90 | 3.11 / 38.11 | 2 | 9 |
7 | 8 | 0.08 | 165 | 15.35 | 280 | 709 | 3.81 / 38.82 | 2 | 15 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 30 | 15.30 | 415 | 190 | 0.19 / 31.46 | 2 | 3 |
2 | 7 | 2005.72 | 38 | 14.97 | 2817 | 1602 | 1.79 / 33.07 | 2 | 9 |
3 | 13 | 1369.96 | 18 | 15.10 | 2077 | 565 | 2.36 / 33.63 | 2 | 13 |
4 | 13 | 791.68 | 18 | 15.24 | 1350 | 370 | 2.73 / 34.00 | 2 | 13 |
5 | 13 | 346.96 | 18 | 15.35 | 769 | 212 | 2.94 / 34.21 | 2 | 13 |
6 | 13 | 16.92 | 18 | 15.42 | 307 | 85 | 3.03 / 34.30 | 2 | 9 |
7 | 8 | 0.16 | 165 | 15.37 | 280 | 710 | 3.74 / 35.01 | 2 | 16 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.32 | 30 | 15.31 | 418 | 192 | 0.19 / 27.61 | 2 | 3 |
2 | 7 | 2008.60 | 38 | 14.97 | 2831 | 1610 | 1.80 / 29.22 | 2 | 8 |
3 | 13 | 1503.40 | 18 | 15.06 | 2232 | 605 | 2.41 / 29.83 | 2 | 11 |
4 | 13 | 941.88 | 18 | 15.17 | 1536 | 419 | 2.83 / 30.25 | 2 | 14 |
5 | 13 | 408.36 | 18 | 15.31 | 852 | 235 | 3.06 / 30.48 | 2 | 14 |
6 | 13 | 21.00 | 18 | 15.39 | 313 | 87 | 3.15 / 30.57 | 2 | 9 |
7 | 8 | 0.08 | 165 | 15.35 | 278 | 704 | 3.85 / 31.27 | 2 | 16 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 30 | 15.30 | 425 | 195 | 0.20 / 23.82 | 2 | 3 |
2 | 7 | 2008.20 | 38 | 14.97 | 2825 | 1607 | 1.80 / 25.42 | 2 | 9 |
3 | 13 | 1417.80 | 18 | 15.08 | 2127 | 577 | 2.38 / 26.00 | 2 | 11 |
4 | 13 | 873.52 | 18 | 15.19 | 1453 | 397 | 2.78 / 26.40 | 2 | 14 |
5 | 13 | 406.52 | 18 | 15.32 | 851 | 235 | 3.01 / 26.63 | 2 | 14 |
6 | 13 | 20.88 | 18 | 15.39 | 314 | 87 | 3.10 / 26.72 | 2 | 9 |
7 | 8 | 0.12 | 165 | 15.36 | 277 | 702 | 3.80 / 27.42 | 2 | 16 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 29 | 15.31 | 417 | 185 | 0.19 / 19.41 | 2 | 3 |
2 | 3 | 1032.64 | 1 | 15.35 | 1721 | 26 | 0.21 / 19.44 | 2 | 9 |
3 | 7 | 2010.40 | 75 | 14.86 | 2821 | 3144 | 3.36 / 22.58 | 2 | 10 |
4 | 13 | 420.08 | 18 | 15.32 | 867 | 239 | 3.59 / 22.82 | 2 | 14 |
5 | 13 | 41.28 | 18 | 15.40 | 337 | 93 | 3.69 / 22.92 | 2 | 9 |
6 | 8 | 0.12 | 165 | 15.37 | 278 | 705 | 4.39 / 23.62 | 2 | 15 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 29 | 15.33 | 396 | 176 | 0.18 / 15.08 | 2 | 3 |
2 | 7 | 2005.48 | 74 | 14.86 | 2813 | 3093 | 3.27 / 18.17 | 2 | 10 |
3 | 13 | 426.72 | 18 | 15.33 | 874 | 241 | 3.51 / 18.41 | 2 | 14 |
4 | 13 | 73.32 | 18 | 15.40 | 381 | 106 | 3.62 / 18.52 | 2 | 10 |
5 | 8 | -0.08 | 165 | 15.37 | 280 | 710 | 4.33 / 19.23 | 2 | 16 |
Average= | 3.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 29 | 15.32 | 415 | 184 | 0.18 / 11.50 | 2 | 3 |
2 | 7 | 1506.72 | 75 | 15.05 | 2209 | 2493 | 2.68 / 14.00 | 2 | 10 |
3 | 13 | 310.92 | 18 | 15.37 | 716 | 198 | 2.88 / 14.19 | 2 | 13 |
4 | 8 | 0.16 | 165 | 15.38 | 279 | 708 | 3.58 / 14.90 | 2 | 12 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 29 | 15.32 | 425 | 189 | 0.19 / 7.87 | 2 | 3 |
2 | 7 | 1510.36 | 74 | 15.04 | 2209 | 2459 | 2.65 / 10.33 | 2 | 10 |
3 | 13 | 320.12 | 18 | 15.36 | 727 | 201 | 2.85 / 10.53 | 2 | 13 |
4 | 13 | 14.84 | 18 | 15.39 | 303 | 84 | 2.93 / 10.61 | 2 | 9 |
5 | 8 | 0.00 | 165 | 15.37 | 278 | 705 | 3.64 / 11.32 | 2 | 15 |
Average= | 2.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 31 | 15.37 | 427 | 203 | 0.20 / 4.31 | 2 | 3 |
2 | 3 | 897.52 | -2 | 15.72 | 0 | 0 | 0.00 / 4.31 | 2 | 3 |
3 | 7 | 1524.12 | 74 | 15.06 | 2220 | 2474 | 2.68 / 6.78 | 2 | 10 |
4 | 13 | 310.36 | 18 | 15.37 | 710 | 196 | 2.87 / 6.98 | 2 | 13 |
5 | 8 | 0.08 | 165 | 15.38 | 277 | 703 | 3.58 / 7.68 | 2 | 13 |
Average= | 2.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 26 | 15.51 | 380 | 153 | 0.15 / 1.56 | 2 | 2 |
2 | 10 | 1037.08 | 2 | 15.38 | 1681 | 52 | 0.20 / 1.61 | 2 | 5 |
3 | 7 | 1006.44 | 74 | 15.22 | 1577 | 1776 | 1.98 / 3.38 | 2 | 12 |
4 | 8 | 0.00 | 165 | 15.42 | 283 | 720 | 2.70 / 4.10 | 2 | 15 |
Average= | 2.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 84.08 | 26 | 15.65 | 346 | 141 | 0.14 / 0.14 | 2 | 2 |
2 | 7 | 99.56 | 74 | 15.64 | 362 | 419 | 0.56 / 0.56 | 2 | 3 |
3 | 8 | 0.28 | 240 | 15.60 | 225 | 842 | 1.40 / 1.40 | 2 | 8 |
Average= | 1.40 (KJ/cycle) |