SIO Argo Site:
Pump Diagnostics Page   



Serial= 3163 WMO= 5906901

Return

←PreviousNext→

Cycle 77 GMT 14/11/2024 1:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 33 15.06 475 236 0.24 / 297.08 2 2
2 7 2012.48 38 14.69 2957 1651 1.89 / 298.73 2 2
3 13 1376.08 18 14.80 2187 583 2.47 / 299.31 2 3
4 13 901.96 18 14.89 1570 421 2.89 / 299.73 2 3
5 13 205.60 18 15.08 620 168 3.06 / 299.90 2 3
6 8 -0.20 165 15.10 317 790 3.85 / 300.69 2 8
Average= 3.85
(KJ/cycle)

Cycle 76 GMT 4/11/2024 6:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 33 15.05 494 245 0.25 / 293.22 2 2
2 7 2011.92 38 14.69 2954 1649 1.89 / 294.87 2 3
3 13 1411.56 18 14.79 2224 592 2.49 / 295.46 2 3
4 13 908.48 18 14.89 1579 423 2.91 / 295.88 2 3
5 13 216.28 18 15.09 635 172 3.08 / 296.05 2 4
6 8 -0.64 165 15.10 316 787 3.87 / 296.84 2 2
Average= 3.86
(KJ/cycle)

Cycle 75 GMT 25/10/2024 11:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 32 15.06 492 237 0.24 / 289.29 2 2
2 7 2008.12 39 14.70 2938 1684 1.92 / 290.98 2 2
3 13 1444.16 18 14.78 2263 602 2.52 / 291.58 2 3
4 13 892.20 18 14.90 1550 416 2.94 / 291.99 2 3
5 13 235.56 18 15.10 663 180 3.12 / 292.17 2 3
6 8 1.56 165 15.11 320 798 3.92 / 292.97 2 3
Average= 3.85
(KJ/cycle)

Cycle 74 GMT 15/10/2024 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 32 15.07 476 230 0.23 / 285.42 2 2
2 7 2004.84 38 14.71 2948 1648 1.88 / 287.06 2 3
3 13 1396.72 18 14.79 2208 588 2.47 / 287.65 2 3
4 13 873.16 18 14.89 1528 410 2.87 / 288.06 2 3
5 13 271.84 18 15.07 717 194 3.07 / 288.26 2 3
6 8 -0.20 165 15.12 320 798 3.87 / 289.05 2 6
Average= 3.85
(KJ/cycle)

Cycle 73 GMT 5/10/2024 21:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 32 15.07 484 233 0.23 / 281.55 2 2
2 7 2010.48 39 14.71 2950 1692 1.93 / 283.24 2 2
3 13 1410.96 18 14.80 2226 593 2.52 / 283.84 2 3
4 13 881.64 18 14.90 1545 414 2.93 / 284.25 2 3
5 13 152.08 18 15.13 544 148 3.08 / 284.40 2 3
6 8 -0.24 165 15.13 316 789 3.87 / 285.19 2 4
Average= 3.85
(KJ/cycle)

Cycle 72 GMT 26/ 9/2024 2:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 32 15.07 485 234 0.23 / 277.73 2 3
2 7 2007.68 38 14.71 2935 1641 1.87 / 279.37 2 2
3 13 1396.68 18 14.80 2200 586 2.46 / 279.96 2 3
4 13 854.96 18 14.92 1505 404 2.86 / 280.36 2 3
5 13 177.24 18 15.11 582 158 3.02 / 280.52 2 3
6 8 -1.44 165 15.12 320 798 3.82 / 281.32 2 3
Average= 3.85
(KJ/cycle)

Cycle 71 GMT 16/ 9/2024 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 32 15.07 486 234 0.23 / 273.87 2 3
2 7 2005.60 38 14.71 2949 1648 1.88 / 275.51 2 2
3 13 1364.12 18 14.81 2169 578 2.46 / 276.09 2 3
4 13 875.88 18 14.91 1532 411 2.87 / 276.50 2 3
5 13 254.00 18 15.10 683 186 3.06 / 276.69 2 2
6 8 1.56 165 15.12 323 806 3.86 / 277.50 2 6
Average= 3.85
(KJ/cycle)

Cycle 70 GMT 6/ 9/2024 12:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 32 15.07 490 236 0.24 / 270.01 2 2
2 7 2007.00 38 14.71 2940 1643 1.88 / 271.65 2 2
3 13 1386.72 18 14.81 2192 584 2.46 / 272.23 2 3
4 13 901.96 18 14.91 1568 421 2.88 / 272.65 2 3
5 13 235.72 18 15.12 656 179 3.06 / 272.83 2 3
6 8 -0.08 165 15.14 320 799 3.86 / 273.63 2 4
Average= 3.85
(KJ/cycle)

Cycle 69 GMT 27/ 8/2024 17:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 32 15.08 492 237 0.24 / 266.13 2 2
2 7 2009.16 38 14.72 2935 1642 1.88 / 267.77 2 2
3 13 1453.64 18 14.81 2273 606 2.49 / 268.38 2 3
4 13 830.84 18 14.95 1469 395 2.88 / 268.77 2 3
5 13 282.36 18 15.10 724 197 3.08 / 268.97 2 3
6 8 1.32 165 15.14 320 799 3.88 / 269.77 2 5
Average= 3.85
(KJ/cycle)

Cycle 68 GMT 17/ 8/2024 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 32 15.10 480 232 0.23 / 262.17 2 2
2 7 2005.40 38 14.72 2936 1642 1.87 / 263.82 2 2
3 13 1326.84 18 14.83 2117 565 2.44 / 264.38 2 3
4 13 899.36 18 14.92 1560 419 2.86 / 264.80 2 3
5 13 207.36 18 15.12 619 168 3.03 / 264.97 2 3
6 13 107.92 18 15.14 484 132 3.16 / 265.10 2 4
7 8 0.04 165 15.13 317 791 3.95 / 265.89 2 4
Average= 3.85
(KJ/cycle)

Cycle 67 GMT 8/ 8/2024 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 32 15.10 470 227 0.23 / 258.30 2 2
2 7 2010.80 38 14.74 2951 1653 1.88 / 259.95 2 2
3 13 1444.32 18 14.84 2262 604 2.48 / 260.55 2 3
4 13 898.32 18 14.94 1561 420 2.90 / 260.97 2 3
5 13 247.28 18 15.13 679 185 3.09 / 261.16 2 3
6 8 -0.52 165 15.15 314 785 3.87 / 261.94 2 5
Average= 3.85
(KJ/cycle)

Cycle 66 GMT 29/ 7/2024 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 32 15.11 475 230 0.23 / 254.50 2 2
2 7 2004.32 38 14.73 2941 1646 1.88 / 256.15 2 2
3 13 1398.72 18 14.84 2199 587 2.46 / 256.74 2 3
4 13 859.92 18 14.94 1504 404 2.87 / 257.14 2 3
5 13 137.52 18 15.17 522 143 3.01 / 257.28 2 3
6 8 0.84 165 15.16 314 785 3.80 / 258.07 2 2
Average= 3.85
(KJ/cycle)

Cycle 65 GMT 19/ 7/2024 13:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 32 15.10 472 228 0.23 / 250.67 2 2
2 7 2005.28 38 14.73 2946 1649 1.88 / 252.32 2 2
3 13 1409.20 18 14.83 2223 593 2.47 / 252.92 2 3
4 13 874.04 18 14.94 1533 412 2.88 / 253.33 2 3
5 13 178.56 18 15.16 584 159 3.04 / 253.49 2 3
6 8 -0.52 165 15.16 314 785 3.83 / 254.27 2 9
Average= 3.85
(KJ/cycle)

Cycle 64 GMT 9/ 7/2024 18: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 32 15.10 484 234 0.23 / 246.85 2 2
2 7 2015.64 38 14.72 2956 1653 1.89 / 248.51 2 2
3 13 1365.96 18 14.83 2158 576 2.46 / 249.08 2 3
4 13 842.72 18 14.95 1486 400 2.86 / 249.48 2 3
5 13 209.20 18 15.14 623 170 3.03 / 249.65 2 3
6 8 -0.52 165 15.15 317 792 3.83 / 250.45 2 9
Average= 3.85
(KJ/cycle)

Cycle 63 GMT 29/ 6/2024 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 32 15.09 483 233 0.23 / 243.06 2 2
2 7 2005.04 38 14.73 2937 1644 1.88 / 244.71 2 2
3 13 1368.20 18 14.85 2167 579 2.46 / 245.29 2 2
4 13 808.28 18 14.97 1436 387 2.84 / 245.67 2 3
5 13 171.68 18 15.17 572 156 3.00 / 245.83 2 3
6 8 -0.36 165 15.16 316 790 3.79 / 246.62 2 6
Average= 3.85
(KJ/cycle)

Cycle 62 GMT 20/ 6/2024 3:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 32 15.12 480 232 0.23 / 239.24 2 2
2 7 2008.36 38 14.73 2939 1645 1.88 / 240.89 2 2
3 13 1408.32 18 14.84 2227 595 2.47 / 241.48 2 3
4 13 826.20 18 14.97 1463 394 2.87 / 241.87 2 3
5 13 185.48 18 15.15 590 161 3.03 / 242.04 2 3
6 8 -0.20 165 15.15 318 795 3.82 / 242.83 2 9
Average= 3.85
(KJ/cycle)

Cycle 61 GMT 10/ 6/2024 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 32 15.11 480 232 0.23 / 235.40 2 2
2 7 2007.88 38 14.73 2946 1649 1.88 / 237.05 2 2
3 13 1485.00 18 14.82 2314 617 2.50 / 237.67 2 2
4 13 840.56 18 14.97 1483 400 2.90 / 238.07 2 3
5 13 115.16 18 15.17 493 135 3.03 / 238.20 2 3
6 8 -0.48 165 15.17 321 803 3.84 / 239.01 2 3
Average= 3.85
(KJ/cycle)

Cycle 60 GMT 31/ 5/2024 13:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 32 15.12 484 234 0.23 / 231.57 2 2
2 7 2010.20 38 14.74 2949 1652 1.89 / 233.22 2 3
3 13 1395.04 18 14.85 2195 587 2.47 / 233.81 2 3
4 13 857.44 18 14.98 1505 406 2.88 / 234.21 2 3
5 13 200.84 18 15.17 609 166 3.04 / 234.38 2 3
6 8 1.20 165 15.17 316 791 3.84 / 235.17 2 4
Average= 3.86
(KJ/cycle)

Cycle 59 GMT 21/ 5/2024 18:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 32 15.12 487 236 0.24 / 227.75 2 2
2 7 2015.44 38 14.74 2939 1646 1.88 / 229.40 2 2
3 13 1415.40 18 14.85 2235 597 2.48 / 230.00 2 3
4 13 836.12 18 14.99 1484 400 2.88 / 230.40 2 3
5 13 153.80 18 15.18 548 150 3.03 / 230.55 2 3
6 8 0.68 165 15.18 315 789 3.82 / 231.34 2 8
Average= 3.86
(KJ/cycle)

Cycle 58 GMT 11/ 5/2024 23:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 32 15.13 482 233 0.23 / 223.93 2 3
2 7 2006.64 38 14.75 2944 1650 1.88 / 225.58 2 2
3 13 1382.28 18 14.86 2185 584 2.47 / 226.16 2 3
4 13 857.32 18 14.98 1503 405 2.87 / 226.57 2 3
5 13 168.40 18 15.18 566 155 3.03 / 226.72 2 4
6 8 0.88 165 15.18 318 796 3.82 / 227.52 2 4
Average= 3.86
(KJ/cycle)

Cycle 57 GMT 2/ 5/2024 4:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 32 15.13 482 233 0.23 / 220.15 2 2
2 7 2010.88 38 14.74 2942 1648 1.88 / 221.80 2 2
3 13 1372.84 18 14.85 2184 584 2.47 / 222.38 2 3
4 13 806.20 18 14.99 1435 387 2.85 / 222.77 2 3
5 13 129.12 18 15.19 512 140 2.99 / 222.91 2 3
6 8 -1.12 165 15.18 313 784 3.78 / 223.69 2 3
Average= 3.86
(KJ/cycle)

Cycle 56 GMT 22/ 4/2024 9:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 32 15.13 482 233 0.23 / 216.37 2 2
2 7 2009.68 38 14.75 2941 1648 1.88 / 218.02 2 3
3 13 1361.60 18 14.88 2160 579 2.46 / 218.59 2 2
4 13 801.40 18 15.00 1435 387 2.85 / 218.98 2 3
5 13 138.20 18 15.19 527 144 2.99 / 219.13 2 3
6 8 -1.36 165 15.19 316 792 3.78 / 219.92 2 3
Average= 3.86
(KJ/cycle)

Cycle 55 GMT 12/ 4/2024 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 32 15.12 481 233 0.23 / 212.56 2 2
2 7 2007.68 38 14.77 2929 1644 1.88 / 214.20 2 2
3 13 1360.84 18 14.90 2137 573 2.45 / 214.78 2 3
4 13 876.64 18 15.00 1516 409 2.86 / 215.19 2 3
5 13 169.64 18 15.20 564 154 3.01 / 215.34 2 5
6 8 2.32 165 15.19 316 792 3.81 / 216.13 2 6
Average= 3.86
(KJ/cycle)

Cycle 54 GMT 2/ 4/2024 19: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 32 15.13 478 231 0.23 / 208.73 2 2
2 7 2008.12 38 14.75 2943 1650 1.88 / 210.38 2 2
3 13 1365.32 18 14.88 2172 582 2.46 / 210.96 2 3
4 13 886.76 18 14.97 1533 413 2.88 / 211.38 2 3
5 13 190.08 18 15.20 594 163 3.04 / 211.54 2 3
6 8 0.12 165 15.19 315 790 3.83 / 212.33 2 3
Average= 3.86
(KJ/cycle)

Cycle 53 GMT 23/ 3/2024 23:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 32 15.14 482 234 0.23 / 204.85 2 2
2 7 2011.64 38 14.77 2946 1653 1.89 / 206.50 2 3
3 13 1377.92 18 14.87 2182 584 2.47 / 207.09 2 3
4 13 896.76 18 14.98 1551 418 2.89 / 207.50 2 3
5 13 239.28 18 15.17 662 181 3.07 / 207.69 2 3
6 8 0.08 165 15.19 325 815 3.88 / 208.50 2 2
Average= 3.86
(KJ/cycle)

Cycle 52 GMT 14/ 3/2024 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 32 15.14 480 233 0.23 / 201.05 2 2
2 7 2014.44 38 14.73 2938 1645 1.88 / 202.69 2 2
3 13 1372.24 18 14.87 2173 582 2.46 / 203.27 2 2
4 13 845.32 18 14.99 1483 400 2.86 / 203.67 2 3
5 13 165.76 18 15.20 560 153 3.01 / 203.83 2 3
6 8 1.36 165 15.19 315 790 3.80 / 204.62 2 6
Average= 3.86
(KJ/cycle)

Cycle 51 GMT 4/ 3/2024 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 32 15.15 483 234 0.23 / 197.16 2 2
2 7 2006.44 38 14.76 2933 1645 1.88 / 198.80 2 2
3 13 1408.76 18 14.87 2222 595 2.47 / 199.40 2 3
4 13 917.08 18 14.98 1591 429 2.90 / 199.83 2 3
5 13 272.04 18 15.17 714 195 3.10 / 200.02 2 3
6 8 -1.76 165 15.20 316 793 3.89 / 200.81 2 3
Average= 3.86
(KJ/cycle)

Cycle 50 GMT 23/ 2/2024 14:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 15.15 482 234 0.23 / 193.32 2 2
2 7 2009.52 38 14.76 2943 1651 1.88 / 194.97 2 2
3 13 1396.48 18 14.87 2196 588 2.47 / 195.56 2 3
4 13 911.88 18 14.98 1582 427 2.90 / 195.98 2 3
5 13 128.28 18 15.22 518 142 3.04 / 196.13 2 3
6 8 -1.76 165 15.20 318 798 3.84 / 196.92 2 4
Average= 3.86
(KJ/cycle)

Cycle 49 GMT 13/ 2/2024 19:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 32 15.15 480 233 0.23 / 189.49 2 3
2 7 2013.32 38 14.76 2945 1652 1.88 / 191.14 2 2
3 13 1412.40 18 14.86 2220 594 2.48 / 191.74 2 3
4 13 827.32 18 15.00 1463 395 2.87 / 192.13 2 3
5 13 156.24 18 15.22 557 153 3.03 / 192.29 2 2
6 8 0.08 165 15.20 319 800 3.83 / 193.09 2 6
Average= 3.86
(KJ/cycle)

Cycle 48 GMT 4/ 2/2024 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 32 15.15 497 241 0.24 / 185.63 2 2
2 7 2007.24 38 14.76 2928 1642 1.88 / 187.27 2 3
3 13 1410.64 18 14.87 2224 595 2.48 / 187.86 2 3
4 13 883.84 18 15.00 1542 416 2.89 / 188.28 2 3
5 13 219.48 18 15.19 638 174 3.07 / 188.45 2 4
6 8 0.32 165 15.20 321 805 3.87 / 189.26 2 3
Average= 3.86
(KJ/cycle)

Cycle 47 GMT 25/ 1/2024 5:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 32 15.16 487 236 0.24 / 181.79 2 2
2 7 2004.80 38 14.76 2929 1643 1.88 / 183.43 2 2
3 13 1359.20 18 14.88 2159 578 2.46 / 184.01 2 3
4 13 871.16 18 14.99 1529 413 2.87 / 184.42 2 3
5 13 133.80 18 15.23 526 144 3.01 / 184.57 2 3
6 8 -0.44 165 15.20 326 818 3.83 / 185.38 3 3
Average= 3.86
(KJ/cycle)

Cycle 46 GMT 15/ 1/2024 10:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 32 15.16 478 232 0.23 / 177.97 2 2
2 7 2013.76 38 14.77 2933 1646 1.88 / 179.62 2 2
3 13 1375.28 18 14.88 2174 582 2.46 / 180.20 2 3
4 13 842.16 18 15.01 1485 401 2.86 / 180.60 2 3
5 13 154.96 18 15.22 550 151 3.01 / 180.76 2 5
6 8 -1.04 165 15.21 318 798 3.81 / 181.55 2 7
Average= 3.86
(KJ/cycle)

Cycle 45 GMT 5/ 1/2024 15:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 32 15.17 478 232 0.23 / 174.13 2 2
2 7 2011.04 38 14.78 2937 1650 1.88 / 175.78 2 3
3 13 1438.28 18 14.89 2252 604 2.49 / 176.39 2 3
4 13 854.80 18 15.01 1495 404 2.89 / 176.79 2 3
5 13 169.64 18 15.21 569 156 3.04 / 176.95 2 5
6 8 0.28 165 15.22 317 796 3.84 / 177.74 2 7
Average= 3.86
(KJ/cycle)

Cycle 44 GMT 26/12/2023 20: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 32 15.16 471 228 0.23 / 170.30 2 2
2 7 2008.24 38 14.78 2942 1652 1.88 / 171.95 2 2
3 13 1359.64 18 14.89 2154 577 2.46 / 172.53 2 3
4 13 872.76 18 15.01 1534 414 2.87 / 172.95 2 3
5 13 173.60 18 15.21 573 157 3.03 / 173.10 2 3
6 8 0.00 165 15.22 318 799 3.83 / 173.90 2 5
Average= 3.86
(KJ/cycle)

Cycle 43 GMT 17/12/2023 1: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 32 15.17 484 235 0.23 / 166.47 2 5
2 7 2008.28 39 14.77 2940 1694 1.93 / 168.16 2 3
3 13 1372.68 18 14.90 2166 581 2.51 / 168.75 2 3
4 13 844.56 18 15.03 1488 403 2.91 / 169.15 2 3
5 13 91.84 18 15.25 453 124 3.04 / 169.27 2 3
6 8 -0.92 165 15.22 319 801 3.84 / 170.07 2 4
Average= 3.87
(KJ/cycle)

Cycle 42 GMT 7/12/2023 5:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 15.18 494 240 0.24 / 162.57 2 2
2 7 2008.20 38 14.78 2938 1650 1.89 / 164.22 2 2
3 13 1456.60 18 14.89 2275 610 2.50 / 164.83 2 3
4 13 832.88 18 15.03 1479 400 2.90 / 165.23 2 3
5 13 283.16 18 15.19 726 199 3.10 / 165.43 2 3
6 8 -0.04 165 15.23 321 807 3.91 / 166.24 2 4
Average= 3.87
(KJ/cycle)

Cycle 41 GMT 27/11/2023 10:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 32 15.19 475 231 0.23 / 158.75 2 2
2 7 2014.84 38 14.79 2941 1653 1.88 / 160.40 2 3
3 13 1368.60 18 14.92 2162 581 2.46 / 160.98 2 2
4 13 790.52 18 15.05 1414 383 2.85 / 161.36 2 3
5 13 116.56 18 15.25 494 136 2.98 / 161.50 2 4
6 8 1.32 165 15.23 331 832 3.81 / 162.33 2 5
Average= 3.87
(KJ/cycle)

Cycle 40 GMT 17/11/2023 15:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 32 15.18 482 234 0.23 / 154.97 2 3
2 7 2004.00 38 14.78 2919 1639 1.87 / 156.61 2 3
3 13 1364.64 18 14.92 2140 575 2.45 / 157.19 2 3
4 13 827.32 18 15.04 1454 394 2.84 / 157.58 2 3
5 13 131.48 18 15.25 512 141 2.98 / 157.72 2 3
6 8 0.52 165 15.24 317 797 3.78 / 158.52 2 5
Average= 3.87
(KJ/cycle)

Cycle 39 GMT 7/11/2023 20:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 32 15.18 484 235 0.24 / 151.08 2 2
2 7 2006.44 38 14.79 2925 1644 1.88 / 152.72 2 2
3 13 1454.24 18 14.90 2257 605 2.48 / 153.33 2 3
4 13 911.32 18 15.02 1555 420 2.90 / 153.75 2 3
5 13 222.52 18 15.21 638 175 3.08 / 153.92 2 4
6 8 0.24 165 15.24 323 812 3.89 / 154.74 2 6
Average= 3.87
(KJ/cycle)

Cycle 38 GMT 29/10/2023 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 32 15.19 480 233 0.23 / 147.28 2 3
2 7 2015.48 38 14.78 2939 1651 1.88 / 148.93 2 2
3 13 1368.80 18 14.92 2151 578 2.46 / 149.51 2 3
4 13 786.72 18 15.06 1397 379 2.84 / 149.89 2 3
5 13 148.16 18 15.24 540 148 2.99 / 150.03 2 3
6 8 -0.84 165 15.23 323 812 3.80 / 150.85 2 5
Average= 3.87
(KJ/cycle)

Cycle 37 GMT 19/10/2023 6: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 32 15.21 484 236 0.24 / 143.43 2 2
2 7 2015.56 38 14.78 2944 1653 1.89 / 145.08 2 2
3 13 1401.68 18 14.91 2210 593 2.48 / 145.67 2 3
4 13 827.04 18 15.04 1466 397 2.88 / 146.07 2 3
5 13 146.00 18 15.25 541 149 3.03 / 146.22 2 2
6 8 -1.84 165 15.23 329 827 3.85 / 147.05 2 7
Average= 3.87
(KJ/cycle)

Cycle 36 GMT 9/10/2023 10:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 32 15.19 490 238 0.24 / 139.60 2 2
2 7 2005.32 38 14.80 2940 1653 1.89 / 141.26 2 2
3 13 1349.04 18 14.92 2135 573 2.47 / 141.83 2 3
4 13 786.72 18 15.07 1416 384 2.85 / 142.22 2 3
5 13 205.52 18 15.23 621 170 3.02 / 142.39 2 4
6 8 -1.60 165 15.25 320 805 3.82 / 143.19 2 5
Average= 3.87
(KJ/cycle)

Cycle 35 GMT 29/ 9/2023 15:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 32 15.20 484 235 0.24 / 135.76 2 3
2 7 2008.68 38 14.80 2924 1644 1.88 / 137.41 2 3
3 13 1452.00 18 14.90 2268 608 2.49 / 138.01 2 3
4 13 830.32 18 15.06 1459 396 2.88 / 138.41 2 3
5 13 166.96 18 15.26 562 154 3.04 / 138.56 2 4
6 8 0.76 165 15.25 319 803 3.84 / 139.37 2 6
Average= 3.87
(KJ/cycle)

Cycle 34 GMT 19/ 9/2023 20:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 32 15.21 478 233 0.23 / 131.88 2 2
2 7 2004.20 39 14.80 2922 1687 1.92 / 133.57 2 2
3 13 1396.44 18 14.93 2192 589 2.51 / 134.16 2 3
4 13 855.96 18 15.05 1504 407 2.92 / 134.57 2 3
5 13 169.20 18 15.26 569 156 3.07 / 134.72 2 3
6 8 -0.08 165 15.26 319 803 3.88 / 135.53 2 3
Average= 3.87
(KJ/cycle)

Cycle 33 GMT 10/ 9/2023 1:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 32 15.19 488 237 0.24 / 128.06 2 2
2 7 2005.00 38 14.79 2917 1639 1.88 / 129.70 2 2
3 13 1358.88 18 14.93 2129 572 2.45 / 130.27 2 3
4 13 874.56 18 15.05 1524 413 2.86 / 130.68 2 3
5 13 199.92 18 15.25 608 167 3.03 / 130.85 2 3
6 8 -0.80 165 15.26 318 801 3.83 / 131.65 2 6
Average= 3.87
(KJ/cycle)

Cycle 32 GMT 31/ 8/2023 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 32 15.20 490 238 0.24 / 124.19 2 2
2 7 2004.72 38 14.80 2915 1639 1.88 / 125.83 2 2
3 13 1383.16 18 14.93 2163 581 2.46 / 126.41 2 3
4 13 883.12 18 15.04 1523 412 2.87 / 126.83 2 3
5 13 215.84 18 15.25 629 173 3.04 / 127.00 2 3
6 8 2.08 165 15.25 327 823 3.87 / 127.82 2 3
Average= 3.87
(KJ/cycle)

Cycle 31 GMT 21/ 8/2023 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 32 15.21 489 238 0.24 / 120.35 2 2
2 7 2010.72 38 14.81 2937 1653 1.89 / 122.00 2 3
3 13 1406.56 18 14.93 2213 595 2.49 / 122.60 2 3
4 13 791.04 18 15.09 1421 386 2.87 / 122.98 2 3
5 13 189.44 18 15.26 593 163 3.03 / 123.15 2 5
6 8 0.96 165 15.26 321 808 3.84 / 123.95 2 9
Average= 3.87
(KJ/cycle)

Cycle 30 GMT 11/ 8/2023 16:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 32 15.22 487 237 0.24 / 116.49 2 2
2 7 2007.00 38 14.81 2925 1646 1.88 / 118.14 2 2
3 13 1360.36 18 14.95 2149 578 2.46 / 118.72 2 3
4 13 918.60 18 15.03 1587 429 2.89 / 119.14 2 3
5 13 138.64 18 15.26 532 146 3.04 / 119.29 2 4
6 8 -0.76 165 15.26 326 821 3.86 / 120.11 2 7
Average= 3.87
(KJ/cycle)

Cycle 29 GMT 1/ 8/2023 21:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 32 15.22 493 240 0.24 / 112.65 2 2
2 7 2004.72 38 14.81 2918 1642 1.88 / 114.29 2 2
3 13 1396.72 18 14.94 2199 591 2.47 / 114.88 2 3
4 13 859.28 18 15.06 1505 408 2.88 / 115.29 2 3
5 13 122.28 18 15.29 504 139 3.02 / 115.43 2 2
6 8 -0.24 165 15.27 328 826 3.85 / 116.25 2 8
Average= 3.88
(KJ/cycle)

Cycle 28 GMT 23/ 7/2023 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 32 15.22 492 240 0.24 / 108.77 2 2
2 7 2005.56 38 14.82 2928 1649 1.89 / 110.41 2 2
3 13 1369.68 18 14.95 2164 582 2.47 / 111.00 2 3
4 13 934.16 18 15.03 1596 432 2.90 / 111.43 2 3
5 13 180.04 18 15.26 588 162 3.06 / 111.59 2 3
6 8 -0.48 165 15.27 324 816 3.88 / 112.41 2 6
Average= 3.88
(KJ/cycle)

Cycle 27 GMT 13/ 7/2023 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 32 15.22 499 243 0.24 / 104.92 2 2
2 7 2012.68 38 14.81 2926 1647 1.89 / 106.57 2 3
3 13 1365.76 18 14.96 2135 575 2.46 / 107.14 2 3
4 13 881.08 18 15.06 1512 410 2.87 / 107.55 2 3
5 13 182.36 18 15.27 561 154 3.03 / 107.71 2 3
6 8 1.84 165 15.26 326 821 3.85 / 108.53 2 5
Average= 3.88
(KJ/cycle)

Cycle 26 GMT 3/ 7/2023 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 32 15.23 495 241 0.24 / 101.05 2 2
2 7 2008.64 38 14.83 2932 1652 1.89 / 102.71 2 2
3 13 1384.52 18 14.96 2183 588 2.48 / 103.29 2 2
4 13 861.44 18 15.08 1511 410 2.89 / 103.70 2 3
5 13 133.52 18 15.29 522 144 3.04 / 103.85 2 3
6 8 1.96 165 15.26 329 828 3.86 / 104.68 2 8
Average= 3.88
(KJ/cycle)

Cycle 25 GMT 23/ 6/2023 17:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 32 15.23 488 238 0.24 / 97.15 2 2
2 7 2006.48 39 14.83 2924 1691 1.93 / 98.84 2 2
3 13 1409.08 18 14.95 2197 591 2.52 / 99.43 2 2
4 13 825.32 18 15.09 1471 400 2.92 / 99.83 2 3
5 13 167.00 18 15.28 569 156 3.08 / 99.98 2 3
6 8 0.64 165 15.27 329 829 3.91 / 100.81 2 5
Average= 3.88
(KJ/cycle)

Cycle 24 GMT 13/ 6/2023 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 32 15.23 495 241 0.24 / 93.22 2 3
2 7 2008.96 38 14.84 2941 1658 1.90 / 94.88 2 2
3 13 1448.04 18 14.94 2267 610 2.51 / 95.49 2 2
4 13 863.32 18 15.08 1515 411 2.92 / 95.90 2 3
5 13 219.00 18 15.27 642 176 3.10 / 96.08 2 3
6 8 -1.16 165 15.27 329 829 3.93 / 96.91 2 6
Average= 3.88
(KJ/cycle)

Cycle 23 GMT 4/ 6/2023 3: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 32 15.24 490 239 0.24 / 89.38 2 3
2 7 2009.40 38 14.83 2927 1649 1.89 / 91.03 2 2
3 13 1370.00 18 14.98 2146 579 2.47 / 91.60 2 3
4 13 840.60 18 15.09 1479 402 2.87 / 92.01 2 3
5 13 176.72 18 15.28 574 158 3.03 / 92.16 2 3
6 8 0.28 165 15.27 325 819 3.85 / 92.98 2 3
Average= 3.87
(KJ/cycle)

Cycle 22 GMT 25/ 5/2023 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 32 15.24 488 238 0.24 / 85.55 2 2
2 7 2004.60 38 14.84 2914 1643 1.88 / 87.20 2 2
3 13 1397.96 18 14.97 2181 588 2.47 / 87.78 2 3
4 13 827.16 18 15.10 1465 398 2.87 / 88.18 2 3
5 13 94.00 18 15.31 469 129 3.00 / 88.31 2 3
6 8 -1.68 165 15.28 327 824 3.82 / 89.14 2 5
Average= 3.88
(KJ/cycle)

Cycle 21 GMT 15/ 5/2023 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 32 15.24 475 232 0.23 / 81.72 2 2
2 7 2005.20 38 14.83 2913 1642 1.87 / 83.36 2 2
3 13 1349.32 18 14.98 2133 575 2.45 / 83.93 2 2
4 13 870.60 18 15.09 1520 413 2.86 / 84.35 2 3
5 13 132.12 18 15.31 525 145 3.01 / 84.49 2 3
6 8 0.16 165 15.29 327 825 3.83 / 85.32 2 4
Average= 3.88
(KJ/cycle)

Cycle 20 GMT 5/ 5/2023 17:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 32 15.24 490 239 0.24 / 77.89 2 2
2 7 2004.12 38 14.84 2914 1643 1.88 / 79.53 2 2
3 13 1367.96 18 14.97 2137 576 2.46 / 80.11 2 3
4 13 840.92 18 15.10 1479 402 2.86 / 80.51 2 3
5 13 182.28 18 15.28 580 160 3.02 / 80.67 2 3
6 8 0.20 165 15.28 323 814 3.83 / 81.48 2 2
Average= 3.88
(KJ/cycle)

Cycle 19 GMT 25/ 4/2023 22:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 32 15.24 485 237 0.24 / 74.01 2 2
2 7 2005.12 38 14.85 2922 1649 1.89 / 75.66 2 2
3 13 1396.88 18 14.98 2182 588 2.47 / 76.25 2 3
4 13 940.08 18 15.08 1588 431 2.90 / 76.68 2 3
5 13 172.04 18 15.31 559 154 3.06 / 76.83 2 3
6 8 1.16 165 15.29 325 820 3.88 / 77.65 2 6
Average= 3.88
(KJ/cycle)

Cycle 18 GMT 16/ 4/2023 3:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 32 15.24 478 233 0.23 / 70.23 2 2
2 7 2006.44 38 14.86 2922 1650 1.88 / 71.88 2 2
3 13 1384.36 18 14.99 2168 585 2.47 / 72.46 2 3
4 13 841.72 18 15.11 1451 395 2.86 / 72.86 2 3
5 13 101.64 18 15.32 447 123 2.99 / 72.98 2 4
6 8 -0.12 165 15.29 314 792 3.78 / 73.77 2 4
Average= 3.88
(KJ/cycle)

Cycle 17 GMT 6/ 4/2023 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 32 15.24 493 240 0.24 / 66.45 2 2
2 7 2003.80 38 14.86 2916 1647 1.89 / 68.10 2 2
3 13 1357.88 18 15.01 2132 576 2.46 / 68.67 2 3
4 13 836.44 18 15.12 1449 394 2.86 / 69.07 2 3
5 13 227.80 18 15.29 622 171 3.03 / 69.24 2 2
6 8 1.68 165 15.30 299 755 3.78 / 69.99 2 6
Average= 3.89
(KJ/cycle)

Cycle 16 GMT 27/ 3/2023 13:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 32 15.25 478 233 0.23 / 62.61 2 2
2 7 2012.64 38 14.85 2923 1649 1.88 / 64.26 2 3
3 13 1406.36 18 14.98 2193 591 2.47 / 64.85 2 3
4 13 822.72 18 15.11 1429 389 2.86 / 65.24 2 3
5 13 221.24 18 15.29 616 170 3.03 / 65.41 2 3
6 8 0.12 165 15.30 319 805 3.84 / 66.21 2 4
Average= 3.89
(KJ/cycle)

Cycle 15 GMT 17/ 3/2023 18:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 32 15.25 466 227 0.23 / 58.81 2 2
2 7 2007.44 38 14.86 2919 1648 1.88 / 60.45 2 2
3 13 1418.40 18 14.98 2206 595 2.47 / 61.05 2 3
4 13 931.60 18 15.08 1577 428 2.90 / 61.48 2 3
5 13 184.08 18 15.31 559 154 3.05 / 61.63 2 3
6 8 2.68 165 15.31 294 743 3.80 / 62.37 2 3
Average= 3.90
(KJ/cycle)

Cycle 14 GMT 7/ 3/2023 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 32 15.26 477 233 0.23 / 55.06 2 2
2 7 2005.12 38 14.85 2914 1644 1.88 / 56.71 2 2
3 13 1354.16 18 15.01 2128 575 2.45 / 57.28 2 3
4 13 755.36 18 15.13 1335 364 2.82 / 57.64 2 3
5 13 107.76 18 15.32 467 129 2.94 / 57.77 2 3
6 8 -0.28 165 15.30 319 805 3.75 / 58.58 2 5
Average= 3.91
(KJ/cycle)

Cycle 13 GMT 26/ 2/2023 4:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 31 15.26 480 227 0.23 / 51.28 2 2
2 7 2006.96 38 14.85 2921 1648 1.88 / 52.92 2 2
3 13 1360.52 18 15.00 2125 574 2.45 / 53.50 2 3
4 13 911.24 18 15.08 1547 420 2.87 / 53.92 2 3
5 13 232.00 18 15.28 626 172 3.04 / 54.09 2 3
6 8 1.28 165 15.31 292 738 3.78 / 54.83 2 4
Average= 3.92
(KJ/cycle)

Cycle 12 GMT 16/ 2/2023 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 31 15.27 487 231 0.23 / 47.48 2 5
2 7 2006.24 38 14.87 2912 1645 1.88 / 49.13 2 2
3 13 1347.60 18 15.02 2121 573 2.45 / 49.70 2 3
4 13 871.56 18 15.11 1509 410 2.86 / 50.11 2 3
5 13 86.12 18 15.34 444 123 2.98 / 50.24 2 5
6 8 0.36 165 15.31 322 813 3.80 / 51.05 2 12
Average= 3.93
(KJ/cycle)

Cycle 11 GMT 6/ 2/2023 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 31 15.26 480 227 0.23 / 43.65 2 2
2 7 2006.76 38 14.87 2922 1651 1.88 / 45.30 2 2
3 13 1435.56 18 15.01 2229 602 2.48 / 45.90 2 3
4 13 826.64 18 15.14 1446 394 2.87 / 46.30 2 3
5 13 131.24 18 15.35 504 139 3.01 / 46.44 2 3
6 8 -1.24 165 15.32 323 816 3.83 / 47.25 2 5
Average= 3.94
(KJ/cycle)

Cycle 10 GMT 27/ 1/2023 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 31 15.27 482 228 0.23 / 39.05 2 2
2 7 2009.04 74 14.75 2914 3181 3.41 / 42.23 2 3
3 13 532.04 18 15.21 1054 289 3.70 / 42.52 2 3
4 13 20.32 18 15.35 350 97 3.79 / 42.61 2 2
5 8 0.68 165 15.30 321 810 4.60 / 43.42 2 7
Average= 3.95
(KJ/cycle)

Cycle 9 GMT 17/ 1/2023 22: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 31 15.27 473 224 0.22 / 34.47 2 2
2 7 2012.76 75 14.76 2919 3231 3.46 / 37.71 2 2
3 13 399.68 18 15.26 860 236 3.69 / 37.94 2 3
4 13 20.68 18 15.37 334 92 3.78 / 38.03 2 6
5 8 0.96 165 15.33 310 784 4.57 / 38.82 2 3
Average= 3.88
(KJ/cycle)

Cycle 8 GMT 8/ 1/2023 1:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 31 15.26 486 230 0.23 / 29.97 2 6
2 7 2004.80 74 14.77 2910 3181 3.41 / 33.15 2 3
3 13 396.56 18 15.28 860 237 3.65 / 33.39 2 4
4 13 24.28 18 15.38 337 93 3.74 / 33.48 2 4
5 8 1.16 165 15.33 305 771 4.51 / 34.25 2 11
Average= 3.81
(KJ/cycle)

Cycle 7 GMT 29/12/2022 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 31 15.26 493 233 0.23 / 25.38 2 3
2 7 2011.12 74 14.77 2920 3192 3.42 / 28.57 2 3
3 13 402.04 18 15.26 882 242 3.67 / 28.81 2 3
4 13 21.52 18 15.36 354 98 3.76 / 28.91 2 7
5 8 0.60 165 15.32 327 827 4.59 / 29.74 2 3
Average= 3.72
(KJ/cycle)

Cycle 6 GMT 19/12/2022 7:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 29 15.27 470 208 0.21 / 20.76 2 3
2 10 1013.68 2 15.25 1760 54 0.26 / 20.81 2 3
3 7 2002.84 74 14.77 2907 3177 3.44 / 23.99 2 3
4 13 402.16 18 15.27 882 242 3.68 / 24.23 2 3
5 13 23.12 18 15.36 358 99 3.78 / 24.33 2 10
6 8 -1.00 165 15.32 324 819 4.60 / 25.15 2 8
Average= 3.59
(KJ/cycle)

Cycle 5 GMT 9/12/2022 10:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 29 15.29 462 205 0.20 / 16.20 2 2
2 3 1030.28 1 15.31 1765 27 0.23 / 16.22 2 2
3 7 2012.96 74 14.77 2923 3195 3.43 / 19.42 2 3
4 13 389.12 18 15.27 846 233 3.66 / 19.65 2 3
5 13 19.52 18 15.36 343 95 3.75 / 19.75 2 2
6 8 0.08 165 15.32 317 801 4.56 / 20.55 2 5
Average= 3.42
(KJ/cycle)

Cycle 4 GMT 29/11/2022 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 37 15.27 461 260 0.26 / 12.48 2 2
2 3 717.68 -5 15.65 0 0 0.00 / 12.48 2 2
3 3 923.16 -1 15.68 0 0 0.00 / 12.48 2 2
4 7 1526.08 74 14.97 2312 2561 2.82 / 15.04 2 3
5 13 155.40 18 15.36 540 149 2.97 / 15.19 2 3
6 8 0.12 165 15.35 316 800 3.77 / 15.99 2 4
Average= 3.20
(KJ/cycle)

Cycle 3 GMT 28/11/2022 13:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 29 15.29 470 208 0.21 / 8.51 2 2
2 10 1057.96 4 15.20 1792 109 0.32 / 8.62 2 2
3 10 1096.68 2 15.20 1851 56 0.37 / 8.67 2 2
4 3 1107.88 3 15.22 1886 86 0.46 / 8.76 2 2
5 7 1509.84 74 14.95 2299 2543 3.00 / 11.30 2 3
6 13 149.80 18 15.33 520 143 3.15 / 11.45 2 3
7 8 2.20 165 15.32 307 776 3.92 / 12.22 2 3
Average= 3.06
(KJ/cycle)

Cycle 2 GMT 27/11/2022 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 31 15.30 462 219 0.22 / 4.83 2 2
2 3 914.52 -2 15.64 0 0 0.00 / 4.83 2 2
3 7 1507.60 74 14.96 2290 2535 2.75 / 7.37 2 3
4 13 145.64 18 15.34 526 145 2.90 / 7.51 2 3
5 8 -0.68 165 15.33 310 784 3.68 / 8.30 2 4
Average= 2.77
(KJ/cycle)

Cycle 1 GMT 26/11/2022 14:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 26 15.48 427 172 0.17 / 1.90 2 2
2 10 1005.92 3 15.28 1719 79 0.25 / 1.98 2 2
3 7 1009.20 74 15.12 1651 1847 2.10 / 3.83 2 3
4 8 -0.04 165 15.36 310 786 2.88 / 4.61 2 6
Average= 2.31
(KJ/cycle)

Cycle 0 GMT 26/11/2022 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.72 26 15.62 434 176 0.18 / 0.18 2 2
2 7 139.40 74 15.58 465 536 0.71 / 0.71 2 3
3 8 0.16 240 15.55 273 1019 1.73 / 1.73 2 9
Average= 1.73
(KJ/cycle)