SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 32 | 15.05 | 450 | 217 | 0.22 / 272.59 | 2 | 3 |
2 | 7 | 2009.80 | 38 | 14.83 | 2915 | 1643 | 1.86 / 274.23 | 2 | 7 |
3 | 13 | 1323.24 | 18 | 14.89 | 2091 | 560 | 2.42 / 274.79 | 2 | 8 |
4 | 13 | 768.24 | 18 | 14.98 | 1375 | 371 | 2.79 / 275.16 | 2 | 10 |
5 | 13 | 252.28 | 18 | 15.07 | 673 | 183 | 2.97 / 275.35 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.08 | 296 | 737 | 3.71 / 276.08 | 2 | 5 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 32 | 15.05 | 460 | 222 | 0.22 / 268.82 | 2 | 3 |
2 | 7 | 2004.60 | 39 | 14.84 | 2903 | 1680 | 1.90 / 270.50 | 2 | 6 |
3 | 13 | 1367.44 | 18 | 14.90 | 2145 | 575 | 2.48 / 271.08 | 2 | 9 |
4 | 13 | 788.48 | 18 | 14.99 | 1403 | 379 | 2.86 / 271.46 | 2 | 10 |
5 | 13 | 264.88 | 18 | 15.09 | 687 | 187 | 3.04 / 271.64 | 2 | 8 |
6 | 8 | 0.20 | 165 | 15.10 | 293 | 730 | 3.77 / 272.37 | 2 | 3 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 32 | 15.07 | 456 | 220 | 0.22 / 265.09 | 2 | 3 |
2 | 7 | 2012.44 | 38 | 14.83 | 2906 | 1638 | 1.86 / 266.72 | 2 | 5 |
3 | 13 | 1277.24 | 18 | 14.91 | 2026 | 544 | 2.40 / 267.27 | 2 | 9 |
4 | 13 | 849.44 | 18 | 14.98 | 1480 | 399 | 2.80 / 267.67 | 2 | 10 |
5 | 13 | 323.76 | 18 | 15.09 | 778 | 211 | 3.01 / 267.88 | 2 | 10 |
6 | 8 | 0.00 | 165 | 15.10 | 291 | 725 | 3.74 / 268.60 | 2 | 6 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 32 | 15.07 | 446 | 215 | 0.22 / 261.28 | 2 | 3 |
2 | 7 | 2007.64 | 38 | 14.85 | 2911 | 1643 | 1.86 / 262.92 | 2 | 7 |
3 | 13 | 1436.28 | 18 | 14.91 | 2232 | 599 | 2.46 / 263.52 | 2 | 8 |
4 | 13 | 833.64 | 18 | 14.99 | 1463 | 395 | 2.85 / 263.92 | 2 | 10 |
5 | 13 | 334.72 | 18 | 15.10 | 787 | 214 | 3.07 / 264.13 | 2 | 10 |
6 | 8 | 0.32 | 165 | 15.12 | 294 | 733 | 3.80 / 264.87 | 2 | 28 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 32 | 15.07 | 451 | 217 | 0.22 / 257.53 | 2 | 3 |
2 | 7 | 2006.52 | 38 | 14.85 | 2910 | 1642 | 1.86 / 259.17 | 2 | 7 |
3 | 13 | 1352.44 | 18 | 14.91 | 2126 | 571 | 2.43 / 259.74 | 2 | 9 |
4 | 13 | 816.20 | 18 | 14.99 | 1443 | 389 | 2.82 / 260.13 | 2 | 10 |
5 | 13 | 316.76 | 18 | 15.10 | 763 | 207 | 3.03 / 260.34 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.11 | 291 | 726 | 3.75 / 261.07 | 2 | 6 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 32 | 15.09 | 458 | 221 | 0.22 / 253.76 | 2 | 3 |
2 | 7 | 2004.28 | 38 | 14.85 | 2910 | 1642 | 1.86 / 255.40 | 2 | 7 |
3 | 13 | 1353.36 | 18 | 14.92 | 2130 | 572 | 2.44 / 255.97 | 2 | 8 |
4 | 13 | 834.80 | 18 | 14.99 | 1467 | 396 | 2.83 / 256.37 | 2 | 10 |
5 | 13 | 301.24 | 18 | 15.11 | 738 | 201 | 3.03 / 256.57 | 2 | 9 |
6 | 8 | 0.12 | 165 | 15.12 | 298 | 743 | 3.78 / 257.31 | 2 | 4 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 31 | 15.09 | 452 | 211 | 0.21 / 249.94 | 2 | 3 |
2 | 7 | 2011.80 | 38 | 14.86 | 2909 | 1643 | 1.85 / 251.58 | 2 | 6 |
3 | 13 | 1366.36 | 18 | 14.93 | 2141 | 575 | 2.43 / 252.16 | 2 | 8 |
4 | 13 | 933.40 | 18 | 14.97 | 1603 | 432 | 2.86 / 252.59 | 2 | 10 |
5 | 13 | 336.16 | 18 | 15.11 | 788 | 214 | 3.08 / 252.80 | 2 | 10 |
6 | 8 | 0.20 | 165 | 15.13 | 294 | 734 | 3.81 / 253.54 | 2 | 13 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 31 | 15.10 | 443 | 207 | 0.21 / 246.19 | 2 | 2 |
2 | 7 | 2004.60 | 38 | 14.85 | 2903 | 1638 | 1.85 / 247.83 | 2 | 6 |
3 | 13 | 1345.20 | 18 | 14.93 | 2120 | 570 | 2.42 / 248.40 | 2 | 9 |
4 | 13 | 853.56 | 18 | 14.99 | 1487 | 401 | 2.82 / 248.80 | 2 | 10 |
5 | 13 | 304.68 | 18 | 15.12 | 741 | 202 | 3.02 / 249.01 | 2 | 10 |
6 | 8 | 0.08 | 165 | 15.13 | 290 | 724 | 3.74 / 249.73 | 2 | 4 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 31 | 15.10 | 452 | 212 | 0.21 / 242.48 | 2 | 3 |
2 | 7 | 2004.20 | 38 | 14.86 | 2904 | 1640 | 1.85 / 244.12 | 2 | 7 |
3 | 13 | 1306.56 | 18 | 14.94 | 2075 | 558 | 2.41 / 244.68 | 2 | 9 |
4 | 13 | 832.60 | 18 | 15.02 | 1460 | 395 | 2.80 / 245.07 | 2 | 10 |
5 | 13 | 297.72 | 18 | 15.12 | 726 | 198 | 3.00 / 245.27 | 2 | 8 |
6 | 8 | 0.12 | 165 | 15.14 | 288 | 719 | 3.72 / 245.99 | 2 | 15 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 31 | 15.11 | 434 | 203 | 0.20 / 238.68 | 2 | 3 |
2 | 7 | 2004.92 | 38 | 14.86 | 2914 | 1645 | 1.85 / 240.33 | 2 | 6 |
3 | 13 | 1392.84 | 18 | 14.94 | 2183 | 587 | 2.44 / 240.92 | 2 | 9 |
4 | 13 | 851.52 | 18 | 15.02 | 1486 | 402 | 2.84 / 241.32 | 2 | 10 |
5 | 13 | 338.36 | 18 | 15.12 | 789 | 215 | 3.05 / 241.53 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.14 | 293 | 732 | 3.78 / 242.27 | 2 | 13 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 31 | 15.09 | 446 | 209 | 0.21 / 234.97 | 2 | 3 |
2 | 7 | 2004.80 | 38 | 14.85 | 2904 | 1639 | 1.85 / 236.61 | 2 | 5 |
3 | 13 | 1348.88 | 18 | 14.93 | 2122 | 570 | 2.42 / 237.18 | 2 | 9 |
4 | 13 | 814.88 | 18 | 15.01 | 1438 | 389 | 2.81 / 237.56 | 2 | 10 |
5 | 13 | 277.56 | 18 | 15.13 | 699 | 190 | 3.00 / 237.75 | 2 | 9 |
6 | 8 | 0.12 | 165 | 15.14 | 291 | 727 | 3.72 / 238.48 | 2 | 12 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 31 | 15.10 | 434 | 203 | 0.20 / 231.11 | 2 | 3 |
2 | 7 | 2009.08 | 38 | 14.87 | 2908 | 1643 | 1.85 / 232.75 | 2 | 6 |
3 | 13 | 1403.56 | 18 | 14.93 | 2186 | 587 | 2.43 / 233.34 | 2 | 8 |
4 | 13 | 859.72 | 18 | 15.02 | 1494 | 404 | 2.84 / 233.74 | 2 | 11 |
5 | 13 | 284.08 | 18 | 15.13 | 713 | 194 | 3.03 / 233.93 | 2 | 9 |
6 | 13 | 48.84 | 18 | 15.17 | 372 | 102 | 3.13 / 234.04 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.14 | 289 | 722 | 3.86 / 234.76 | 2 | 9 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 31 | 15.10 | 451 | 211 | 0.21 / 227.31 | 2 | 3 |
2 | 7 | 2010.92 | 38 | 14.86 | 2914 | 1645 | 1.86 / 228.95 | 2 | 7 |
3 | 13 | 1274.04 | 18 | 14.95 | 2030 | 546 | 2.40 / 229.50 | 2 | 9 |
4 | 13 | 772.36 | 18 | 15.04 | 1380 | 374 | 2.78 / 229.87 | 2 | 10 |
5 | 13 | 333.96 | 18 | 15.13 | 779 | 212 | 2.99 / 230.08 | 2 | 9 |
6 | 13 | 26.60 | 18 | 15.17 | 339 | 93 | 3.08 / 230.18 | 2 | 5 |
7 | 8 | 0.04 | 165 | 15.15 | 291 | 727 | 3.81 / 230.90 | 2 | 32 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 31 | 15.11 | 429 | 201 | 0.20 / 223.59 | 2 | 3 |
2 | 7 | 2009.92 | 38 | 14.87 | 2909 | 1644 | 1.84 / 225.24 | 2 | 6 |
3 | 13 | 1261.68 | 18 | 14.98 | 2011 | 542 | 2.39 / 225.78 | 2 | 8 |
4 | 13 | 854.20 | 18 | 15.03 | 1495 | 404 | 2.79 / 226.18 | 2 | 10 |
5 | 13 | 264.04 | 18 | 15.15 | 680 | 185 | 2.98 / 226.37 | 2 | 9 |
6 | 8 | 0.20 | 165 | 15.15 | 290 | 725 | 3.70 / 227.09 | 2 | 6 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 31 | 15.11 | 446 | 209 | 0.21 / 219.80 | 2 | 3 |
2 | 7 | 2007.76 | 38 | 14.88 | 2902 | 1641 | 1.85 / 221.44 | 2 | 7 |
3 | 13 | 1308.08 | 18 | 14.96 | 2073 | 558 | 2.41 / 222.00 | 2 | 9 |
4 | 13 | 777.76 | 18 | 15.05 | 1395 | 378 | 2.79 / 222.38 | 2 | 11 |
5 | 13 | 286.00 | 18 | 15.15 | 713 | 194 | 2.98 / 222.57 | 2 | 9 |
6 | 13 | 18.08 | 18 | 15.19 | 325 | 89 | 3.07 / 222.66 | 2 | 17 |
7 | 8 | 0.08 | 165 | 15.15 | 292 | 730 | 3.80 / 223.39 | 2 | 18 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.24 | 31 | 15.10 | 449 | 210 | 0.21 / 216.11 | 2 | 3 |
2 | 7 | 2010.08 | 38 | 14.88 | 2908 | 1644 | 1.85 / 217.75 | 2 | 5 |
3 | 13 | 1342.92 | 18 | 14.96 | 2116 | 570 | 2.42 / 218.32 | 2 | 9 |
4 | 13 | 771.80 | 18 | 15.06 | 1385 | 375 | 2.80 / 218.70 | 2 | 10 |
5 | 13 | 241.72 | 18 | 15.16 | 646 | 176 | 2.98 / 218.88 | 2 | 7 |
6 | 8 | 0.28 | 165 | 15.16 | 287 | 718 | 3.69 / 219.59 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 31 | 15.12 | 420 | 197 | 0.20 / 212.19 | 2 | 3 |
2 | 7 | 2011.08 | 38 | 14.90 | 2912 | 1649 | 1.85 / 213.84 | 2 | 6 |
3 | 13 | 1438.84 | 18 | 14.95 | 2229 | 600 | 2.45 / 214.44 | 2 | 9 |
4 | 13 | 861.96 | 18 | 15.03 | 1495 | 404 | 2.85 / 214.85 | 2 | 10 |
5 | 13 | 365.96 | 18 | 15.14 | 827 | 225 | 3.08 / 215.07 | 2 | 10 |
6 | 13 | 60.04 | 18 | 15.19 | 383 | 105 | 3.18 / 215.18 | 2 | 5 |
7 | 8 | -0.04 | 165 | 15.16 | 289 | 723 | 3.90 / 215.90 | 2 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 31 | 15.12 | 429 | 201 | 0.20 / 208.34 | 2 | 3 |
2 | 7 | 2010.68 | 38 | 14.88 | 2908 | 1644 | 1.85 / 209.98 | 2 | 6 |
3 | 13 | 1382.08 | 18 | 14.96 | 2163 | 582 | 2.43 / 210.57 | 2 | 8 |
4 | 13 | 847.04 | 18 | 15.05 | 1480 | 401 | 2.83 / 210.97 | 2 | 10 |
5 | 13 | 307.52 | 18 | 15.16 | 745 | 203 | 3.03 / 211.17 | 2 | 9 |
6 | 13 | 59.12 | 18 | 15.18 | 385 | 105 | 3.14 / 211.28 | 2 | 6 |
7 | 8 | 0.00 | 165 | 15.15 | 288 | 720 | 3.86 / 212.00 | 2 | 15 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 31 | 15.13 | 424 | 199 | 0.20 / 204.58 | 2 | 3 |
2 | 7 | 2010.44 | 38 | 14.88 | 2902 | 1641 | 1.84 / 206.22 | 2 | 6 |
3 | 13 | 1402.08 | 18 | 14.94 | 2191 | 589 | 2.43 / 206.81 | 2 | 8 |
4 | 13 | 862.00 | 18 | 15.03 | 1494 | 404 | 2.83 / 207.22 | 2 | 10 |
5 | 13 | 338.08 | 18 | 15.14 | 786 | 214 | 3.05 / 207.43 | 2 | 10 |
6 | 8 | 0.16 | 165 | 15.15 | 283 | 707 | 3.75 / 208.14 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 31 | 15.12 | 426 | 200 | 0.20 / 200.89 | 2 | 3 |
2 | 7 | 2003.36 | 38 | 14.88 | 2894 | 1636 | 1.84 / 202.52 | 2 | 6 |
3 | 13 | 1391.48 | 18 | 14.96 | 2171 | 585 | 2.42 / 203.11 | 2 | 9 |
4 | 13 | 806.72 | 18 | 15.06 | 1420 | 385 | 2.81 / 203.49 | 2 | 10 |
5 | 13 | 276.76 | 18 | 15.16 | 691 | 189 | 2.99 / 203.68 | 2 | 8 |
6 | 8 | 0.20 | 165 | 15.16 | 281 | 703 | 3.70 / 204.38 | 2 | 13 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 31 | 15.12 | 443 | 208 | 0.21 / 197.06 | 2 | 3 |
2 | 7 | 2007.60 | 38 | 14.88 | 2905 | 1643 | 1.85 / 198.71 | 2 | 6 |
3 | 13 | 1383.44 | 18 | 14.96 | 2164 | 583 | 2.43 / 199.29 | 2 | 8 |
4 | 13 | 826.72 | 18 | 15.05 | 1448 | 392 | 2.83 / 199.68 | 2 | 10 |
5 | 13 | 291.08 | 18 | 15.16 | 718 | 196 | 3.02 / 199.88 | 2 | 9 |
6 | 13 | 41.40 | 18 | 15.19 | 354 | 97 | 3.12 / 199.97 | 2 | 13 |
7 | 8 | 0.08 | 165 | 15.16 | 285 | 713 | 3.83 / 200.69 | 2 | 24 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 31 | 15.12 | 424 | 199 | 0.20 / 193.22 | 2 | 3 |
2 | 7 | 2009.96 | 38 | 14.89 | 2912 | 1648 | 1.85 / 194.87 | 2 | 6 |
3 | 13 | 1279.72 | 18 | 14.98 | 2031 | 548 | 2.39 / 195.41 | 2 | 8 |
4 | 13 | 894.36 | 18 | 15.03 | 1550 | 419 | 2.81 / 195.83 | 2 | 10 |
5 | 13 | 288.72 | 18 | 15.15 | 714 | 195 | 3.01 / 196.03 | 2 | 8 |
6 | 13 | 83.84 | 18 | 15.17 | 416 | 114 | 3.12 / 196.14 | 2 | 6 |
7 | 8 | 0.20 | 165 | 15.15 | 286 | 715 | 3.84 / 196.86 | 2 | 13 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 31 | 15.12 | 448 | 210 | 0.21 / 189.38 | 2 | 3 |
2 | 7 | 2005.64 | 38 | 14.88 | 2903 | 1641 | 1.85 / 191.02 | 2 | 7 |
3 | 13 | 1384.32 | 18 | 14.97 | 2165 | 583 | 2.43 / 191.60 | 2 | 8 |
4 | 13 | 846.52 | 18 | 15.05 | 1486 | 403 | 2.84 / 192.01 | 2 | 10 |
5 | 13 | 311.88 | 18 | 15.16 | 746 | 204 | 3.04 / 192.21 | 2 | 9 |
6 | 13 | 29.84 | 18 | 15.19 | 336 | 92 | 3.13 / 192.30 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.16 | 287 | 718 | 3.85 / 193.02 | 2 | 10 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 31 | 15.12 | 423 | 198 | 0.20 / 185.50 | 2 | 3 |
2 | 7 | 2008.88 | 38 | 14.89 | 2908 | 1645 | 1.84 / 187.15 | 2 | 7 |
3 | 13 | 1394.68 | 18 | 14.97 | 2181 | 588 | 2.43 / 187.73 | 2 | 9 |
4 | 13 | 858.04 | 18 | 15.06 | 1499 | 406 | 2.84 / 188.14 | 2 | 10 |
5 | 13 | 303.64 | 18 | 15.16 | 740 | 202 | 3.04 / 188.34 | 2 | 9 |
6 | 13 | 55.96 | 18 | 15.18 | 384 | 105 | 3.14 / 188.45 | 2 | 6 |
7 | 8 | 0.04 | 165 | 15.15 | 289 | 722 | 3.87 / 189.17 | 2 | 22 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 31 | 15.12 | 448 | 210 | 0.21 / 181.70 | 2 | 3 |
2 | 7 | 2012.52 | 38 | 14.90 | 2909 | 1647 | 1.86 / 183.34 | 2 | 6 |
3 | 13 | 1283.96 | 18 | 15.00 | 2040 | 551 | 2.41 / 183.90 | 2 | 9 |
4 | 13 | 854.84 | 18 | 15.07 | 1492 | 405 | 2.81 / 184.30 | 2 | 11 |
5 | 13 | 263.48 | 18 | 15.17 | 675 | 184 | 3.00 / 184.48 | 2 | 8 |
6 | 13 | 35.04 | 18 | 15.20 | 345 | 94 | 3.09 / 184.58 | 2 | 10 |
7 | 8 | 0.20 | 165 | 15.17 | 289 | 723 | 3.81 / 185.30 | 2 | 6 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.20 | 31 | 15.14 | 448 | 210 | 0.21 / 177.87 | 2 | 3 |
2 | 7 | 2003.72 | 38 | 14.90 | 2899 | 1641 | 1.85 / 179.51 | 2 | 8 |
3 | 13 | 1384.00 | 18 | 14.99 | 2162 | 583 | 2.44 / 180.09 | 2 | 8 |
4 | 13 | 805.16 | 18 | 15.07 | 1433 | 389 | 2.82 / 180.48 | 2 | 10 |
5 | 13 | 275.12 | 18 | 15.17 | 694 | 190 | 3.01 / 180.67 | 2 | 8 |
6 | 13 | 37.92 | 18 | 15.20 | 349 | 95 | 3.11 / 180.76 | 2 | 5 |
7 | 8 | 0.08 | 165 | 15.17 | 289 | 723 | 3.83 / 181.49 | 2 | 15 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.72 | 31 | 15.14 | 446 | 209 | 0.21 / 173.99 | 2 | 3 |
2 | 7 | 2009.48 | 39 | 14.92 | 2907 | 1692 | 1.90 / 175.68 | 2 | 7 |
3 | 13 | 1311.16 | 18 | 15.01 | 2071 | 560 | 2.46 / 176.24 | 2 | 9 |
4 | 13 | 821.68 | 18 | 15.09 | 1446 | 393 | 2.85 / 176.63 | 2 | 10 |
5 | 13 | 320.04 | 18 | 15.18 | 760 | 208 | 3.06 / 176.84 | 2 | 9 |
6 | 13 | 32.48 | 18 | 15.21 | 344 | 94 | 3.15 / 176.94 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.17 | 287 | 718 | 3.87 / 177.66 | 2 | 12 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.84 | 31 | 15.16 | 439 | 206 | 0.21 / 170.12 | 2 | 3 |
2 | 7 | 2004.24 | 38 | 14.91 | 2896 | 1641 | 1.85 / 171.77 | 2 | 6 |
3 | 13 | 1382.48 | 18 | 14.99 | 2170 | 586 | 2.43 / 172.35 | 2 | 9 |
4 | 13 | 830.40 | 18 | 15.08 | 1467 | 398 | 2.83 / 172.75 | 2 | 10 |
5 | 13 | 293.76 | 18 | 15.18 | 717 | 196 | 3.03 / 172.95 | 2 | 9 |
6 | 13 | 43.40 | 18 | 15.21 | 366 | 100 | 3.13 / 173.05 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.18 | 294 | 736 | 3.86 / 173.78 | 2 | 7 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 31 | 15.14 | 444 | 208 | 0.21 / 166.16 | 2 | 3 |
2 | 7 | 2005.68 | 38 | 14.91 | 2904 | 1645 | 1.85 / 167.80 | 2 | 6 |
3 | 13 | 1353.12 | 18 | 14.99 | 2118 | 571 | 2.43 / 168.37 | 2 | 8 |
4 | 13 | 873.24 | 18 | 15.07 | 1517 | 412 | 2.84 / 168.78 | 2 | 10 |
5 | 13 | 281.44 | 18 | 15.18 | 709 | 194 | 3.03 / 168.98 | 2 | 9 |
6 | 13 | 21.32 | 18 | 15.21 | 327 | 90 | 3.12 / 169.07 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.18 | 288 | 721 | 3.84 / 169.79 | 2 | 17 |
8 | 14 | 0.16 | 30 | 15.15 | 287 | 130 | 3.97 / 169.92 | 2 | 13 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 31 | 15.14 | 446 | 209 | 0.21 / 162.33 | 2 | 3 |
2 | 7 | 2003.00 | 38 | 14.90 | 2901 | 1643 | 1.85 / 163.97 | 2 | 6 |
3 | 13 | 1342.00 | 18 | 14.99 | 2116 | 571 | 2.42 / 164.54 | 2 | 9 |
4 | 13 | 826.04 | 18 | 15.07 | 1456 | 395 | 2.82 / 164.94 | 2 | 10 |
5 | 13 | 280.72 | 18 | 15.18 | 706 | 193 | 3.01 / 165.13 | 2 | 9 |
6 | 13 | 19.80 | 18 | 15.21 | 326 | 89 | 3.10 / 165.22 | 2 | 10 |
7 | 8 | 0.12 | 165 | 15.18 | 291 | 729 | 3.83 / 165.95 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 31 | 15.13 | 444 | 208 | 0.21 / 158.45 | 2 | 3 |
2 | 7 | 2009.32 | 38 | 14.91 | 2903 | 1645 | 1.85 / 160.09 | 2 | 6 |
3 | 13 | 1438.88 | 18 | 14.98 | 2240 | 604 | 2.46 / 160.70 | 2 | 9 |
4 | 13 | 880.56 | 18 | 15.07 | 1528 | 414 | 2.87 / 161.11 | 2 | 10 |
5 | 13 | 278.52 | 18 | 15.19 | 700 | 191 | 3.06 / 161.30 | 2 | 9 |
6 | 13 | 18.00 | 18 | 15.22 | 320 | 88 | 3.15 / 161.39 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.18 | 290 | 726 | 3.88 / 162.12 | 2 | 10 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 31 | 15.15 | 450 | 211 | 0.21 / 154.60 | 2 | 3 |
2 | 7 | 2004.08 | 38 | 14.92 | 2908 | 1649 | 1.86 / 156.25 | 2 | 7 |
3 | 13 | 1359.76 | 18 | 15.00 | 2146 | 579 | 2.44 / 156.83 | 2 | 9 |
4 | 13 | 829.08 | 18 | 15.08 | 1459 | 396 | 2.84 / 157.22 | 2 | 10 |
5 | 13 | 290.48 | 18 | 15.19 | 720 | 197 | 3.03 / 157.42 | 2 | 9 |
6 | 13 | 24.16 | 18 | 15.22 | 336 | 92 | 3.12 / 157.51 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.18 | 291 | 729 | 3.85 / 158.24 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.36 | 31 | 15.14 | 448 | 210 | 0.21 / 150.80 | 2 | 3 |
2 | 7 | 2009.20 | 39 | 14.92 | 2908 | 1692 | 1.90 / 152.49 | 2 | 6 |
3 | 13 | 1310.04 | 18 | 15.01 | 2078 | 561 | 2.46 / 153.05 | 2 | 9 |
4 | 13 | 819.72 | 18 | 15.10 | 1444 | 392 | 2.86 / 153.45 | 2 | 10 |
5 | 13 | 306.72 | 18 | 15.18 | 756 | 207 | 3.06 / 153.65 | 2 | 10 |
6 | 8 | 0.16 | 165 | 15.19 | 293 | 734 | 3.80 / 154.39 | 2 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 31 | 15.14 | 456 | 214 | 0.21 / 147.07 | 2 | 3 |
2 | 7 | 2008.72 | 38 | 14.91 | 2910 | 1649 | 1.86 / 148.72 | 2 | 6 |
3 | 13 | 1294.16 | 18 | 15.01 | 2052 | 554 | 2.42 / 149.27 | 2 | 9 |
4 | 13 | 784.84 | 18 | 15.10 | 1402 | 381 | 2.80 / 149.65 | 2 | 10 |
5 | 13 | 298.60 | 18 | 15.18 | 737 | 201 | 3.00 / 149.85 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.19 | 294 | 737 | 3.74 / 150.59 | 2 | 12 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 31 | 15.15 | 448 | 210 | 0.21 / 143.32 | 2 | 3 |
2 | 7 | 2006.16 | 38 | 14.90 | 2897 | 1640 | 1.85 / 144.96 | 2 | 7 |
3 | 13 | 1329.16 | 18 | 15.01 | 2100 | 567 | 2.42 / 145.53 | 2 | 9 |
4 | 13 | 830.92 | 18 | 15.08 | 1458 | 396 | 2.81 / 145.93 | 2 | 10 |
5 | 13 | 283.36 | 18 | 15.18 | 714 | 195 | 3.01 / 146.12 | 2 | 9 |
6 | 8 | 0.24 | 165 | 15.19 | 292 | 732 | 3.74 / 146.85 | 2 | 12 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.60 | 31 | 15.16 | 457 | 215 | 0.21 / 139.57 | 2 | 3 |
2 | 7 | 2011.68 | 38 | 14.93 | 2911 | 1652 | 1.87 / 141.22 | 2 | 6 |
3 | 13 | 1351.72 | 18 | 15.02 | 2125 | 575 | 2.44 / 141.80 | 2 | 10 |
4 | 13 | 808.48 | 18 | 15.10 | 1436 | 390 | 2.83 / 142.19 | 2 | 10 |
5 | 13 | 267.16 | 18 | 15.20 | 688 | 188 | 3.02 / 142.38 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.21 | 294 | 738 | 3.76 / 143.11 | 2 | 9 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 31 | 15.16 | 450 | 211 | 0.21 / 135.80 | 2 | 3 |
2 | 7 | 2008.16 | 38 | 14.92 | 2902 | 1645 | 1.86 / 137.45 | 2 | 8 |
3 | 13 | 1309.68 | 18 | 15.02 | 2067 | 559 | 2.42 / 138.00 | 2 | 9 |
4 | 13 | 776.84 | 18 | 15.10 | 1387 | 377 | 2.79 / 138.38 | 2 | 11 |
5 | 13 | 367.68 | 18 | 15.19 | 829 | 227 | 3.02 / 138.61 | 2 | 10 |
6 | 8 | 0.04 | 165 | 15.20 | 298 | 747 | 3.77 / 139.36 | 2 | 12 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 31 | 15.17 | 445 | 209 | 0.21 / 132.08 | 2 | 3 |
2 | 7 | 2010.16 | 38 | 14.92 | 2905 | 1647 | 1.86 / 133.72 | 2 | 6 |
3 | 13 | 1330.28 | 18 | 15.01 | 2090 | 565 | 2.42 / 134.29 | 2 | 9 |
4 | 13 | 755.16 | 18 | 15.11 | 1357 | 369 | 2.79 / 134.66 | 2 | 10 |
5 | 13 | 304.12 | 18 | 15.21 | 738 | 202 | 2.99 / 134.86 | 2 | 10 |
6 | 8 | 0.00 | 165 | 15.20 | 291 | 730 | 3.72 / 135.59 | 2 | 12 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 31 | 15.16 | 429 | 202 | 0.20 / 128.35 | 2 | 3 |
2 | 7 | 2006.28 | 38 | 14.92 | 2900 | 1644 | 1.85 / 129.99 | 2 | 7 |
3 | 13 | 1307.64 | 18 | 15.03 | 2067 | 559 | 2.41 / 130.55 | 2 | 8 |
4 | 13 | 868.08 | 18 | 15.09 | 1502 | 408 | 2.81 / 130.96 | 2 | 10 |
5 | 13 | 268.28 | 18 | 15.21 | 682 | 187 | 3.00 / 131.15 | 2 | 9 |
6 | 8 | 0.00 | 165 | 15.21 | 287 | 720 | 3.72 / 131.87 | 2 | 8 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.64 | 31 | 15.16 | 445 | 209 | 0.21 / 124.65 | 2 | 3 |
2 | 7 | 2004.20 | 38 | 14.92 | 2897 | 1642 | 1.85 / 126.30 | 2 | 7 |
3 | 13 | 1318.28 | 18 | 15.03 | 2075 | 561 | 2.41 / 126.86 | 2 | 9 |
4 | 13 | 753.04 | 18 | 15.13 | 1353 | 368 | 2.78 / 127.22 | 2 | 11 |
5 | 13 | 258.36 | 18 | 15.20 | 684 | 187 | 2.97 / 127.41 | 2 | 9 |
6 | 8 | 0.00 | 165 | 15.21 | 293 | 735 | 3.70 / 128.15 | 2 | 14 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 31 | 15.17 | 428 | 201 | 0.20 / 120.95 | 2 | 3 |
2 | 7 | 2007.72 | 38 | 14.92 | 2898 | 1643 | 1.84 / 122.59 | 2 | 6 |
3 | 13 | 1288.84 | 18 | 15.03 | 2046 | 554 | 2.40 / 123.14 | 2 | 9 |
4 | 13 | 784.52 | 18 | 15.11 | 1398 | 380 | 2.78 / 123.52 | 2 | 10 |
5 | 13 | 294.92 | 18 | 15.21 | 725 | 198 | 2.98 / 123.72 | 2 | 10 |
6 | 8 | 0.24 | 165 | 15.21 | 287 | 720 | 3.70 / 124.44 | 2 | 12 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 31 | 15.19 | 444 | 209 | 0.21 / 117.26 | 2 | 3 |
2 | 7 | 2006.48 | 38 | 14.93 | 2897 | 1644 | 1.85 / 118.90 | 2 | 6 |
3 | 13 | 1352.72 | 18 | 15.02 | 2121 | 573 | 2.43 / 119.47 | 2 | 9 |
4 | 13 | 756.08 | 18 | 15.12 | 1371 | 373 | 2.80 / 119.85 | 2 | 10 |
5 | 13 | 269.96 | 18 | 15.21 | 683 | 187 | 2.99 / 120.03 | 2 | 9 |
6 | 8 | 0.12 | 165 | 15.21 | 284 | 713 | 3.70 / 120.75 | 2 | 14 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 31 | 15.19 | 449 | 211 | 0.21 / 113.52 | 2 | 3 |
2 | 7 | 2005.64 | 38 | 14.96 | 2901 | 1649 | 1.86 / 115.17 | 2 | 6 |
3 | 13 | 1348.88 | 18 | 15.04 | 2113 | 572 | 2.43 / 115.74 | 2 | 9 |
4 | 13 | 771.48 | 18 | 15.13 | 1375 | 374 | 2.81 / 116.12 | 2 | 10 |
5 | 13 | 340.48 | 18 | 15.21 | 783 | 214 | 3.02 / 116.33 | 2 | 9 |
6 | 8 | 0.20 | 165 | 15.23 | 285 | 716 | 3.74 / 117.05 | 2 | 15 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 31 | 15.19 | 437 | 206 | 0.21 / 109.79 | 2 | 3 |
2 | 7 | 2011.28 | 38 | 14.95 | 2907 | 1651 | 1.86 / 111.45 | 2 | 6 |
3 | 13 | 1401.12 | 18 | 15.03 | 2186 | 591 | 2.45 / 112.04 | 2 | 9 |
4 | 13 | 759.76 | 18 | 15.13 | 1362 | 371 | 2.82 / 112.41 | 2 | 10 |
5 | 13 | 279.80 | 18 | 15.22 | 696 | 191 | 3.01 / 112.60 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.23 | 283 | 711 | 3.72 / 113.31 | 2 | 6 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 31 | 15.18 | 452 | 213 | 0.21 / 106.05 | 2 | 3 |
2 | 7 | 2012.80 | 38 | 14.95 | 2912 | 1654 | 1.87 / 107.71 | 2 | 7 |
3 | 13 | 1435.44 | 18 | 15.02 | 2229 | 603 | 2.47 / 108.31 | 2 | 10 |
4 | 13 | 767.96 | 18 | 15.14 | 1366 | 372 | 2.84 / 108.68 | 2 | 10 |
5 | 13 | 279.08 | 18 | 15.22 | 692 | 190 | 3.03 / 108.87 | 2 | 9 |
6 | 8 | 0.08 | 165 | 15.23 | 286 | 719 | 3.75 / 109.59 | 2 | 7 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 31 | 15.19 | 446 | 210 | 0.21 / 102.17 | 2 | 3 |
2 | 7 | 2012.24 | 38 | 14.95 | 2904 | 1650 | 1.86 / 103.82 | 2 | 7 |
3 | 13 | 1396.20 | 18 | 15.04 | 2181 | 590 | 2.45 / 104.41 | 2 | 10 |
4 | 13 | 845.96 | 18 | 15.13 | 1471 | 401 | 2.85 / 104.81 | 2 | 10 |
5 | 13 | 290.96 | 18 | 15.22 | 716 | 196 | 3.05 / 105.00 | 2 | 9 |
6 | 13 | 94.08 | 18 | 15.25 | 429 | 118 | 3.16 / 105.12 | 2 | 7 |
7 | 8 | 0.04 | 165 | 15.22 | 286 | 718 | 3.88 / 105.84 | 2 | 16 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 31 | 15.18 | 427 | 201 | 0.20 / 98.42 | 2 | 3 |
2 | 7 | 2008.44 | 38 | 14.95 | 2902 | 1649 | 1.85 / 100.07 | 2 | 6 |
3 | 13 | 1342.08 | 18 | 15.04 | 2116 | 573 | 2.42 / 100.64 | 2 | 8 |
4 | 13 | 774.32 | 18 | 15.14 | 1391 | 379 | 2.80 / 101.02 | 2 | 10 |
5 | 13 | 331.76 | 18 | 15.22 | 779 | 213 | 3.01 / 101.23 | 2 | 10 |
6 | 8 | 0.04 | 165 | 15.23 | 287 | 721 | 3.74 / 101.96 | 2 | 3 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 31 | 15.18 | 438 | 206 | 0.21 / 94.71 | 2 | 3 |
2 | 7 | 2004.52 | 38 | 14.96 | 2884 | 1639 | 1.85 / 96.34 | 2 | 6 |
3 | 13 | 1305.56 | 18 | 15.05 | 2057 | 557 | 2.40 / 96.90 | 2 | 9 |
4 | 13 | 870.08 | 18 | 15.11 | 1503 | 409 | 2.81 / 97.31 | 2 | 11 |
5 | 13 | 285.64 | 18 | 15.22 | 695 | 190 | 3.00 / 97.50 | 2 | 9 |
6 | 8 | 0.20 | 165 | 15.22 | 286 | 718 | 3.72 / 98.22 | 2 | 14 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 31 | 15.19 | 444 | 209 | 0.21 / 90.83 | 2 | 3 |
2 | 7 | 2005.56 | 38 | 14.96 | 2901 | 1649 | 1.86 / 92.48 | 2 | 8 |
3 | 13 | 1365.08 | 18 | 15.03 | 2134 | 577 | 2.44 / 93.06 | 2 | 10 |
4 | 13 | 885.88 | 18 | 15.11 | 1522 | 414 | 2.85 / 93.47 | 2 | 10 |
5 | 13 | 289.76 | 18 | 15.22 | 709 | 194 | 3.04 / 93.67 | 2 | 9 |
6 | 13 | 90.68 | 18 | 15.23 | 422 | 116 | 3.16 / 93.78 | 2 | 8 |
7 | 8 | 0.12 | 165 | 15.22 | 286 | 718 | 3.88 / 94.50 | 2 | 7 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 31 | 15.18 | 458 | 216 | 0.22 / 87.01 | 2 | 3 |
2 | 7 | 2007.56 | 38 | 14.96 | 2910 | 1654 | 1.87 / 88.66 | 2 | 8 |
3 | 13 | 1335.52 | 18 | 15.05 | 2104 | 570 | 2.44 / 89.23 | 2 | 10 |
4 | 13 | 804.68 | 18 | 15.13 | 1417 | 386 | 2.83 / 89.62 | 2 | 10 |
5 | 13 | 261.80 | 18 | 15.23 | 682 | 187 | 3.01 / 89.81 | 2 | 9 |
6 | 13 | 15.80 | 18 | 15.26 | 317 | 87 | 3.10 / 89.89 | 2 | 6 |
7 | 8 | 0.04 | 165 | 15.23 | 290 | 729 | 3.83 / 90.62 | 2 | 11 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.44 | 30 | 15.19 | 456 | 208 | 0.21 / 83.27 | 2 | 3 |
2 | 7 | 2012.56 | 38 | 14.96 | 2903 | 1650 | 1.86 / 84.92 | 2 | 6 |
3 | 13 | 1260.60 | 18 | 15.06 | 1996 | 541 | 2.40 / 85.46 | 2 | 9 |
4 | 13 | 827.88 | 18 | 15.13 | 1445 | 394 | 2.79 / 85.85 | 2 | 11 |
5 | 13 | 276.60 | 18 | 15.23 | 685 | 188 | 2.98 / 86.04 | 2 | 9 |
6 | 8 | 0.24 | 165 | 15.23 | 299 | 751 | 3.73 / 86.79 | 2 | 17 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 30 | 15.20 | 420 | 192 | 0.19 / 79.46 | 2 | 3 |
2 | 7 | 2006.92 | 38 | 14.98 | 2888 | 1644 | 1.84 / 81.10 | 2 | 8 |
3 | 13 | 1288.60 | 18 | 15.08 | 2028 | 550 | 2.39 / 81.65 | 2 | 10 |
4 | 13 | 830.16 | 18 | 15.14 | 1440 | 392 | 2.78 / 82.05 | 2 | 10 |
5 | 13 | 275.72 | 18 | 15.24 | 679 | 186 | 2.96 / 82.23 | 2 | 9 |
6 | 13 | 38.00 | 18 | 15.27 | 346 | 95 | 3.06 / 82.33 | 2 | 9 |
7 | 8 | 0.00 | 165 | 15.24 | 292 | 734 | 3.79 / 83.06 | 2 | 6 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 30 | 15.21 | 404 | 184 | 0.18 / 75.61 | 2 | 3 |
2 | 7 | 2007.12 | 39 | 14.97 | 2893 | 1689 | 1.87 / 77.30 | 2 | 7 |
3 | 13 | 1341.64 | 18 | 15.07 | 2103 | 570 | 2.44 / 77.87 | 2 | 9 |
4 | 13 | 850.84 | 18 | 15.14 | 1462 | 398 | 2.84 / 78.27 | 2 | 10 |
5 | 13 | 286.60 | 18 | 15.24 | 693 | 190 | 3.03 / 78.46 | 2 | 10 |
6 | 13 | 81.40 | 18 | 15.26 | 393 | 108 | 3.14 / 78.57 | 2 | 8 |
7 | 8 | 0.00 | 165 | 15.23 | 279 | 701 | 3.84 / 79.27 | 2 | 18 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 30 | 15.21 | 421 | 192 | 0.19 / 71.91 | 2 | 3 |
2 | 7 | 2002.96 | 38 | 14.99 | 2887 | 1644 | 1.84 / 73.55 | 2 | 7 |
3 | 13 | 1332.20 | 18 | 15.08 | 2081 | 565 | 2.40 / 74.12 | 2 | 10 |
4 | 13 | 833.24 | 18 | 15.15 | 1446 | 394 | 2.80 / 74.51 | 2 | 10 |
5 | 13 | 238.40 | 18 | 15.26 | 618 | 170 | 2.97 / 74.68 | 2 | 8 |
6 | 13 | 9.84 | 18 | 15.28 | 283 | 78 | 3.04 / 74.76 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.25 | 264 | 664 | 3.71 / 75.43 | 2 | 15 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 30 | 15.22 | 405 | 185 | 0.18 / 68.21 | 2 | 3 |
2 | 7 | 2002.20 | 38 | 14.99 | 2886 | 1644 | 1.83 / 69.85 | 2 | 7 |
3 | 13 | 1276.64 | 18 | 15.09 | 2016 | 548 | 2.38 / 70.40 | 2 | 10 |
4 | 13 | 806.96 | 18 | 15.16 | 1408 | 384 | 2.76 / 70.79 | 2 | 11 |
5 | 13 | 269.96 | 18 | 15.25 | 664 | 182 | 2.94 / 70.97 | 2 | 9 |
6 | 13 | 14.32 | 18 | 15.28 | 293 | 81 | 3.02 / 71.05 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.25 | 266 | 669 | 3.69 / 71.72 | 2 | 14 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 30 | 15.21 | 400 | 183 | 0.18 / 64.62 | 2 | 3 |
2 | 7 | 2003.48 | 38 | 14.99 | 2889 | 1646 | 1.83 / 66.26 | 2 | 7 |
3 | 13 | 1298.16 | 18 | 15.09 | 2041 | 554 | 2.38 / 66.82 | 2 | 9 |
4 | 13 | 766.36 | 18 | 15.18 | 1363 | 372 | 2.75 / 67.19 | 2 | 11 |
5 | 13 | 226.44 | 18 | 15.27 | 608 | 167 | 2.92 / 67.36 | 2 | 9 |
6 | 8 | 0.16 | 165 | 15.26 | 265 | 667 | 3.59 / 68.03 | 2 | 12 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 30 | 15.22 | 397 | 181 | 0.18 / 60.92 | 2 | 3 |
2 | 7 | 2008.00 | 38 | 14.99 | 2898 | 1651 | 1.83 / 62.57 | 2 | 7 |
3 | 13 | 1288.48 | 18 | 15.10 | 2027 | 551 | 2.38 / 63.12 | 2 | 10 |
4 | 13 | 748.48 | 18 | 15.18 | 1337 | 365 | 2.75 / 63.48 | 2 | 11 |
5 | 13 | 260.96 | 18 | 15.25 | 651 | 179 | 2.93 / 63.66 | 2 | 9 |
6 | 13 | 65.08 | 18 | 15.27 | 370 | 102 | 3.03 / 63.76 | 2 | 6 |
7 | 8 | 0.00 | 165 | 15.24 | 267 | 671 | 3.70 / 64.44 | 2 | 5 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 30 | 15.21 | 410 | 187 | 0.19 / 57.34 | 2 | 3 |
2 | 7 | 2009.88 | 38 | 15.00 | 2896 | 1651 | 1.84 / 58.99 | 2 | 7 |
3 | 13 | 1253.08 | 18 | 15.10 | 1989 | 541 | 2.38 / 59.53 | 2 | 10 |
4 | 13 | 769.36 | 18 | 15.17 | 1358 | 371 | 2.75 / 59.91 | 2 | 11 |
5 | 13 | 218.28 | 18 | 15.27 | 594 | 163 | 2.91 / 60.07 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.26 | 265 | 667 | 3.58 / 60.74 | 2 | 11 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.52 | 30 | 15.23 | 424 | 194 | 0.19 / 53.63 | 2 | 3 |
2 | 7 | 2002.88 | 38 | 15.01 | 2891 | 1649 | 1.84 / 55.28 | 2 | 7 |
3 | 13 | 1305.28 | 18 | 15.10 | 2048 | 557 | 2.40 / 55.84 | 2 | 9 |
4 | 13 | 778.60 | 18 | 15.18 | 1370 | 374 | 2.77 / 56.21 | 2 | 11 |
5 | 13 | 273.44 | 18 | 15.27 | 674 | 185 | 2.96 / 56.40 | 2 | 9 |
6 | 13 | 38.28 | 18 | 15.28 | 331 | 91 | 3.05 / 56.49 | 2 | 7 |
7 | 8 | 0.32 | 165 | 15.25 | 265 | 667 | 3.72 / 57.16 | 2 | 12 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 30 | 15.23 | 407 | 186 | 0.19 / 49.92 | 2 | 3 |
2 | 7 | 2008.04 | 38 | 15.00 | 2895 | 1650 | 1.84 / 51.57 | 2 | 6 |
3 | 13 | 1261.16 | 18 | 15.10 | 1989 | 541 | 2.38 / 52.11 | 2 | 9 |
4 | 13 | 752.88 | 18 | 15.17 | 1339 | 366 | 2.74 / 52.47 | 2 | 10 |
5 | 13 | 297.36 | 18 | 15.26 | 712 | 196 | 2.94 / 52.67 | 2 | 10 |
6 | 13 | 49.72 | 18 | 15.28 | 346 | 95 | 3.03 / 52.76 | 2 | 5 |
7 | 8 | 0.16 | 165 | 15.26 | 268 | 675 | 3.71 / 53.44 | 2 | 12 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 30 | 15.22 | 405 | 185 | 0.18 / 46.18 | 2 | 3 |
2 | 7 | 2004.04 | 38 | 15.02 | 2897 | 1653 | 1.84 / 47.83 | 2 | 7 |
3 | 13 | 1339.36 | 18 | 15.11 | 2091 | 569 | 2.41 / 48.40 | 2 | 9 |
4 | 13 | 792.04 | 18 | 15.19 | 1391 | 380 | 2.79 / 48.78 | 2 | 11 |
5 | 13 | 249.56 | 18 | 15.27 | 639 | 176 | 2.96 / 48.96 | 2 | 9 |
6 | 13 | 51.88 | 18 | 15.30 | 353 | 97 | 3.06 / 49.05 | 2 | 8 |
7 | 8 | 0.04 | 165 | 15.26 | 269 | 677 | 3.74 / 49.73 | 2 | 12 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 30 | 15.23 | 398 | 182 | 0.18 / 42.49 | 2 | 3 |
2 | 7 | 2003.28 | 38 | 15.02 | 2890 | 1649 | 1.83 / 44.14 | 2 | 7 |
3 | 13 | 1245.20 | 18 | 15.12 | 1968 | 536 | 2.37 / 44.68 | 2 | 9 |
4 | 13 | 821.88 | 18 | 15.19 | 1427 | 390 | 2.76 / 45.07 | 2 | 10 |
5 | 13 | 215.92 | 18 | 15.28 | 586 | 161 | 2.92 / 45.23 | 2 | 9 |
6 | 13 | 44.04 | 18 | 15.30 | 337 | 93 | 3.01 / 45.32 | 2 | 6 |
7 | 8 | 0.00 | 165 | 15.26 | 266 | 670 | 3.68 / 45.99 | 2 | 13 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 30 | 15.23 | 405 | 185 | 0.19 / 38.73 | 2 | 3 |
2 | 7 | 2008.36 | 39 | 15.01 | 2891 | 1692 | 1.88 / 40.42 | 2 | 6 |
3 | 13 | 1364.48 | 18 | 15.09 | 2117 | 575 | 2.45 / 41.00 | 2 | 9 |
4 | 13 | 777.36 | 18 | 15.18 | 1370 | 374 | 2.83 / 41.37 | 2 | 10 |
5 | 13 | 255.84 | 18 | 15.28 | 641 | 176 | 3.00 / 41.55 | 2 | 8 |
6 | 13 | 60.40 | 18 | 15.30 | 361 | 99 | 3.10 / 41.65 | 2 | 8 |
7 | 8 | 0.08 | 165 | 15.27 | 265 | 668 | 3.77 / 42.31 | 2 | 12 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 30 | 15.24 | 397 | 182 | 0.18 / 34.99 | 2 | 3 |
2 | 7 | 2004.00 | 38 | 15.03 | 2893 | 1652 | 1.83 / 36.64 | 2 | 6 |
3 | 13 | 1381.36 | 18 | 15.12 | 2147 | 584 | 2.42 / 37.23 | 2 | 9 |
4 | 13 | 793.84 | 18 | 15.20 | 1389 | 380 | 2.80 / 37.61 | 2 | 11 |
5 | 13 | 247.84 | 18 | 15.29 | 641 | 176 | 2.97 / 37.78 | 2 | 9 |
6 | 13 | 29.16 | 18 | 15.31 | 316 | 87 | 3.06 / 37.87 | 2 | 6 |
7 | 8 | 0.24 | 165 | 15.28 | 267 | 673 | 3.73 / 38.54 | 2 | 11 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 30 | 15.24 | 410 | 187 | 0.19 / 31.30 | 2 | 3 |
2 | 7 | 2008.40 | 38 | 15.03 | 2894 | 1653 | 1.84 / 32.95 | 2 | 6 |
3 | 13 | 1260.20 | 18 | 15.13 | 1994 | 543 | 2.38 / 33.49 | 2 | 10 |
4 | 13 | 767.36 | 18 | 15.19 | 1354 | 370 | 2.75 / 33.86 | 2 | 10 |
5 | 13 | 271.28 | 18 | 15.28 | 673 | 185 | 2.94 / 34.05 | 2 | 9 |
6 | 13 | 36.60 | 18 | 15.30 | 327 | 90 | 3.03 / 34.14 | 2 | 7 |
7 | 8 | 0.16 | 165 | 15.27 | 266 | 670 | 3.70 / 34.81 | 2 | 8 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.48 | 30 | 15.23 | 424 | 194 | 0.19 / 27.51 | 2 | 3 |
2 | 7 | 2003.92 | 39 | 15.04 | 2891 | 1696 | 1.89 / 29.20 | 2 | 7 |
3 | 13 | 1361.12 | 18 | 15.11 | 2124 | 578 | 2.47 / 29.78 | 2 | 8 |
4 | 13 | 762.76 | 18 | 15.21 | 1358 | 372 | 2.84 / 30.15 | 2 | 11 |
5 | 13 | 265.28 | 18 | 15.29 | 667 | 184 | 3.02 / 30.34 | 2 | 9 |
6 | 13 | 36.92 | 18 | 15.31 | 331 | 91 | 3.11 / 30.43 | 2 | 7 |
7 | 8 | 0.08 | 165 | 15.28 | 270 | 681 | 3.79 / 31.11 | 2 | 12 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 30 | 15.23 | 401 | 183 | 0.18 / 23.75 | 2 | 3 |
2 | 7 | 2006.40 | 38 | 15.03 | 2892 | 1652 | 1.83 / 25.40 | 2 | 7 |
3 | 13 | 1338.56 | 18 | 15.12 | 2090 | 569 | 2.40 / 25.97 | 2 | 8 |
4 | 13 | 799.68 | 18 | 15.19 | 1400 | 383 | 2.79 / 26.35 | 2 | 10 |
5 | 13 | 296.72 | 18 | 15.28 | 705 | 194 | 2.98 / 26.55 | 2 | 10 |
6 | 13 | 26.20 | 18 | 15.31 | 314 | 87 | 3.07 / 26.63 | 2 | 5 |
7 | 8 | 0.20 | 165 | 15.27 | 270 | 680 | 3.75 / 27.31 | 2 | 9 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 29 | 15.24 | 408 | 180 | 0.18 / 19.97 | 2 | 3 |
2 | 3 | 1023.00 | 1 | 15.34 | 1728 | 27 | 0.21 / 20.00 | 2 | 6 |
3 | 7 | 2008.76 | 38 | 15.04 | 2898 | 1656 | 1.86 / 21.65 | 2 | 7 |
4 | 13 | 1366.64 | 18 | 15.11 | 2124 | 578 | 2.44 / 22.23 | 2 | 8 |
5 | 13 | 772.28 | 18 | 15.21 | 1366 | 374 | 2.81 / 22.61 | 2 | 10 |
6 | 13 | 276.04 | 18 | 15.29 | 681 | 187 | 3.00 / 22.79 | 2 | 9 |
7 | 13 | 35.92 | 18 | 15.32 | 330 | 91 | 3.09 / 22.88 | 2 | 7 |
8 | 8 | 0.08 | 165 | 15.27 | 271 | 683 | 3.78 / 23.57 | 2 | 10 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 29 | 15.25 | 432 | 191 | 0.19 / 15.54 | 2 | 3 |
2 | 7 | 2004.80 | 74 | 14.93 | 2865 | 3165 | 3.36 / 18.71 | 2 | 8 |
3 | 13 | 518.92 | 18 | 15.26 | 1022 | 281 | 3.64 / 18.99 | 2 | 11 |
4 | 13 | 102.24 | 18 | 15.31 | 433 | 119 | 3.76 / 19.11 | 2 | 7 |
5 | 8 | 0.00 | 165 | 15.28 | 272 | 686 | 4.44 / 19.79 | 2 | 8 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 28 | 15.25 | 430 | 184 | 0.18 / 11.79 | 2 | 3 |
2 | 3 | 1021.36 | 1 | 15.36 | 1748 | 27 | 0.21 / 11.82 | 2 | 7 |
3 | 7 | 1524.04 | 74 | 15.07 | 2276 | 2538 | 2.75 / 14.35 | 2 | 8 |
4 | 13 | 294.24 | 18 | 15.31 | 710 | 196 | 2.94 / 14.55 | 2 | 10 |
5 | 13 | 66.00 | 18 | 15.32 | 383 | 106 | 3.05 / 14.66 | 2 | 7 |
6 | 8 | 0.08 | 165 | 15.29 | 275 | 694 | 3.74 / 15.35 | 2 | 13 |
Average= | 3.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 28 | 15.25 | 413 | 176 | 0.18 / 8.07 | 2 | 3 |
2 | 3 | 1027.80 | 1 | 15.35 | 1752 | 27 | 0.20 / 8.09 | 2 | 6 |
3 | 7 | 1507.12 | 74 | 15.08 | 2260 | 2522 | 2.73 / 10.62 | 2 | 8 |
4 | 13 | 286.68 | 18 | 15.31 | 693 | 191 | 2.92 / 10.81 | 2 | 9 |
5 | 13 | 64.48 | 18 | 15.33 | 378 | 104 | 3.02 / 10.91 | 2 | 8 |
6 | 8 | 0.04 | 165 | 15.29 | 275 | 694 | 3.71 / 11.61 | 2 | 14 |
Average= | 2.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 31 | 15.29 | 420 | 199 | 0.20 / 4.37 | 2 | 2 |
2 | 3 | 886.80 | -2 | 15.67 | 0 | 0 | 0.00 / 4.37 | 2 | 2 |
3 | 3 | 966.00 | -1 | 15.68 | 0 | 0 | 0.00 / 4.37 | 2 | 2 |
4 | 7 | 1522.92 | 74 | 15.07 | 2273 | 2535 | 2.73 / 6.91 | 2 | 8 |
5 | 13 | 288.72 | 18 | 15.31 | 695 | 192 | 2.93 / 7.10 | 2 | 10 |
6 | 13 | 67.16 | 18 | 15.32 | 374 | 103 | 3.03 / 7.20 | 2 | 7 |
7 | 8 | 0.08 | 165 | 15.29 | 273 | 689 | 3.72 / 7.89 | 2 | 7 |
Average= | 2.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 26 | 15.47 | 391 | 157 | 0.16 / 1.56 | 3 | 3 |
2 | 10 | 1007.20 | 2 | 15.40 | 1693 | 52 | 0.21 / 1.61 | 2 | 6 |
3 | 7 | 1006.20 | 75 | 15.23 | 1620 | 1850 | 2.06 / 3.47 | 2 | 11 |
4 | 8 | 0.08 | 165 | 15.34 | 280 | 709 | 2.77 / 4.17 | 2 | 6 |
Average= | 2.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 89.52 | 26 | 15.60 | 353 | 143 | 0.14 / 0.14 | 3 | 3 |
2 | 7 | 105.88 | 74 | 15.57 | 374 | 431 | 0.57 / 0.57 | 3 | 3 |
3 | 8 | 0.28 | 240 | 15.53 | 223 | 831 | 1.41 / 1.41 | 3 | 9 |
Average= | 1.41 (KJ/cycle) |