SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.00 | 32 | 15.06 | 465 | 224 | 0.22 / 282.71 | 2 | 2 |
2 | 7 | 2012.20 | 38 | 14.61 | 3049 | 1693 | 1.92 / 284.40 | 2 | 3 |
3 | 13 | 1461.08 | 18 | 14.71 | 2350 | 622 | 2.54 / 285.03 | 2 | 3 |
4 | 13 | 811.20 | 18 | 14.86 | 1491 | 399 | 2.94 / 285.43 | 2 | 3 |
5 | 13 | 403.72 | 18 | 14.99 | 916 | 247 | 3.19 / 285.67 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.08 | 294 | 732 | 3.92 / 286.40 | 2 | 13 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 32 | 15.05 | 432 | 208 | 0.21 / 278.79 | 2 | 2 |
2 | 7 | 2006.92 | 39 | 14.61 | 3038 | 1731 | 1.94 / 280.52 | 2 | 3 |
3 | 13 | 1355.16 | 18 | 14.74 | 2205 | 585 | 2.52 / 281.10 | 2 | 4 |
4 | 13 | 840.72 | 18 | 14.86 | 1534 | 410 | 2.93 / 281.51 | 2 | 3 |
5 | 13 | 388.56 | 18 | 15.00 | 897 | 242 | 3.18 / 281.76 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.08 | 294 | 732 | 3.91 / 282.49 | 2 | 17 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.36 | 32 | 15.06 | 468 | 226 | 0.23 / 274.92 | 2 | 2 |
2 | 7 | 2011.32 | 38 | 14.61 | 3042 | 1689 | 1.91 / 276.61 | 2 | 3 |
3 | 13 | 1361.88 | 18 | 14.75 | 2220 | 589 | 2.50 / 277.20 | 2 | 3 |
4 | 13 | 862.60 | 18 | 14.85 | 1558 | 416 | 2.92 / 277.62 | 2 | 4 |
5 | 13 | 368.80 | 18 | 15.01 | 860 | 232 | 3.15 / 277.85 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.09 | 294 | 732 | 3.88 / 278.58 | 2 | 3 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.76 | 31 | 15.06 | 457 | 213 | 0.21 / 271.00 | 2 | 2 |
2 | 7 | 2009.92 | 39 | 14.63 | 3034 | 1731 | 1.94 / 272.73 | 2 | 3 |
3 | 13 | 1359.12 | 18 | 14.75 | 2212 | 587 | 2.53 / 273.32 | 2 | 3 |
4 | 13 | 904.00 | 18 | 14.85 | 1610 | 430 | 2.96 / 273.75 | 2 | 3 |
5 | 13 | 326.84 | 18 | 15.03 | 799 | 216 | 3.18 / 273.96 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.09 | 294 | 732 | 3.91 / 274.69 | 2 | 8 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.88 | 31 | 15.06 | 463 | 216 | 0.22 / 267.13 | 2 | 2 |
2 | 7 | 2009.84 | 38 | 14.62 | 3032 | 1684 | 1.90 / 268.81 | 2 | 3 |
3 | 13 | 1413.40 | 18 | 14.75 | 2285 | 607 | 2.51 / 269.42 | 2 | 3 |
4 | 13 | 868.32 | 18 | 14.87 | 1565 | 419 | 2.93 / 269.84 | 2 | 3 |
5 | 13 | 330.32 | 18 | 15.05 | 805 | 218 | 3.14 / 270.06 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.10 | 292 | 728 | 3.87 / 270.78 | 2 | 2 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 31 | 15.06 | 465 | 217 | 0.22 / 263.24 | 2 | 2 |
2 | 7 | 2006.36 | 38 | 14.62 | 3035 | 1686 | 1.90 / 264.92 | 2 | 3 |
3 | 13 | 1405.40 | 18 | 14.73 | 2268 | 601 | 2.50 / 265.53 | 2 | 3 |
4 | 13 | 864.12 | 18 | 14.87 | 1562 | 418 | 2.92 / 265.94 | 2 | 3 |
5 | 13 | 363.00 | 18 | 15.03 | 857 | 232 | 3.15 / 266.18 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.10 | 296 | 737 | 3.89 / 266.91 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 31 | 15.08 | 455 | 213 | 0.21 / 259.35 | 2 | 2 |
2 | 7 | 2013.20 | 38 | 14.62 | 3041 | 1689 | 1.90 / 261.04 | 2 | 3 |
3 | 13 | 1366.92 | 18 | 14.76 | 2223 | 591 | 2.49 / 261.63 | 2 | 3 |
4 | 13 | 877.48 | 18 | 14.87 | 1580 | 423 | 2.92 / 262.05 | 2 | 3 |
5 | 13 | 350.56 | 18 | 15.04 | 832 | 225 | 3.14 / 262.28 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.10 | 298 | 742 | 3.88 / 263.02 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 31 | 15.07 | 431 | 201 | 0.20 / 255.48 | 2 | 2 |
2 | 7 | 2008.16 | 38 | 14.63 | 3039 | 1690 | 1.89 / 257.17 | 2 | 3 |
3 | 13 | 1323.92 | 18 | 14.77 | 2169 | 577 | 2.47 / 257.75 | 2 | 4 |
4 | 13 | 842.88 | 18 | 14.88 | 1544 | 414 | 2.88 / 258.16 | 2 | 3 |
5 | 13 | 389.00 | 18 | 15.02 | 898 | 243 | 3.12 / 258.40 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.11 | 295 | 735 | 3.86 / 259.14 | 2 | 6 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.88 | 31 | 15.06 | 465 | 217 | 0.22 / 251.55 | 2 | 2 |
2 | 7 | 2010.80 | 38 | 14.62 | 3032 | 1684 | 1.90 / 253.24 | 2 | 3 |
3 | 13 | 1361.68 | 18 | 14.76 | 2214 | 588 | 2.49 / 253.82 | 2 | 3 |
4 | 13 | 804.72 | 18 | 14.89 | 1482 | 397 | 2.89 / 254.22 | 2 | 3 |
5 | 13 | 365.92 | 18 | 15.04 | 855 | 231 | 3.12 / 254.45 | 2 | 3 |
6 | 13 | 33.76 | 18 | 15.14 | 347 | 95 | 3.21 / 254.55 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.11 | 293 | 730 | 3.94 / 255.28 | 2 | 7 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 31 | 15.08 | 456 | 213 | 0.21 / 247.72 | 2 | 2 |
2 | 7 | 2005.88 | 38 | 14.62 | 3039 | 1688 | 1.90 / 249.41 | 2 | 3 |
3 | 13 | 1331.56 | 18 | 14.76 | 2173 | 577 | 2.48 / 249.99 | 2 | 3 |
4 | 13 | 808.40 | 18 | 14.89 | 1490 | 399 | 2.88 / 250.39 | 2 | 4 |
5 | 13 | 317.72 | 18 | 15.06 | 784 | 213 | 3.09 / 250.60 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.12 | 295 | 736 | 3.83 / 251.33 | 2 | 11 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 31 | 15.07 | 461 | 215 | 0.22 / 243.84 | 2 | 2 |
2 | 7 | 2008.96 | 38 | 14.63 | 3039 | 1690 | 1.90 / 245.53 | 2 | 3 |
3 | 13 | 1392.80 | 18 | 14.76 | 2252 | 598 | 2.50 / 246.13 | 2 | 3 |
4 | 13 | 832.04 | 18 | 14.90 | 1512 | 406 | 2.91 / 246.53 | 2 | 3 |
5 | 13 | 381.64 | 18 | 15.03 | 886 | 240 | 3.15 / 246.77 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.12 | 294 | 733 | 3.88 / 247.51 | 2 | 10 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 31 | 15.10 | 437 | 205 | 0.20 / 239.86 | 2 | 2 |
2 | 7 | 2012.96 | 38 | 14.64 | 3043 | 1693 | 1.90 / 241.55 | 2 | 2 |
3 | 13 | 1388.32 | 18 | 14.77 | 2248 | 598 | 2.50 / 242.15 | 2 | 4 |
4 | 13 | 855.56 | 18 | 14.90 | 1550 | 416 | 2.91 / 242.57 | 2 | 3 |
5 | 13 | 359.60 | 18 | 15.06 | 855 | 232 | 3.14 / 242.80 | 2 | 3 |
6 | 13 | 15.80 | 18 | 15.15 | 321 | 88 | 3.23 / 242.89 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.11 | 297 | 740 | 3.97 / 243.63 | 2 | 2 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 31 | 15.08 | 438 | 205 | 0.20 / 236.02 | 2 | 2 |
2 | 7 | 2003.28 | 38 | 14.64 | 3030 | 1686 | 1.89 / 237.71 | 2 | 3 |
3 | 13 | 1269.16 | 18 | 14.80 | 2106 | 561 | 2.45 / 238.27 | 2 | 3 |
4 | 13 | 854.00 | 18 | 14.90 | 1550 | 416 | 2.87 / 238.69 | 2 | 3 |
5 | 13 | 352.76 | 18 | 15.06 | 853 | 231 | 3.10 / 238.92 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.13 | 296 | 739 | 3.84 / 239.66 | 2 | 18 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.64 | 31 | 15.09 | 462 | 216 | 0.22 / 231.97 | 2 | 2 |
2 | 7 | 2015.56 | 38 | 14.65 | 3047 | 1696 | 1.91 / 233.67 | 2 | 3 |
3 | 13 | 1427.68 | 18 | 14.77 | 2306 | 613 | 2.53 / 234.28 | 2 | 3 |
4 | 13 | 929.32 | 18 | 14.88 | 1655 | 443 | 2.97 / 234.72 | 2 | 4 |
5 | 13 | 372.36 | 18 | 15.05 | 877 | 238 | 3.21 / 234.96 | 2 | 3 |
6 | 13 | 73.76 | 18 | 15.15 | 409 | 112 | 3.32 / 235.07 | 2 | 3 |
7 | 8 | 0.28 | 165 | 15.11 | 299 | 745 | 4.06 / 235.82 | 2 | 7 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.92 | 31 | 15.10 | 475 | 222 | 0.22 / 227.97 | 2 | 2 |
2 | 7 | 2003.36 | 38 | 14.64 | 3035 | 1688 | 1.91 / 229.66 | 2 | 3 |
3 | 13 | 1360.04 | 18 | 14.78 | 2216 | 590 | 2.50 / 230.25 | 2 | 3 |
4 | 13 | 909.48 | 18 | 14.87 | 1624 | 435 | 2.94 / 230.69 | 2 | 3 |
5 | 13 | 354.92 | 18 | 15.06 | 849 | 230 | 3.17 / 230.92 | 2 | 3 |
6 | 13 | 22.80 | 18 | 15.16 | 336 | 92 | 3.26 / 231.01 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.12 | 299 | 746 | 4.00 / 231.75 | 2 | 9 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 31 | 15.10 | 434 | 203 | 0.20 / 223.98 | 2 | 3 |
2 | 7 | 2007.08 | 38 | 14.64 | 3037 | 1690 | 1.89 / 225.67 | 2 | 3 |
3 | 13 | 1406.68 | 18 | 14.79 | 2283 | 608 | 2.50 / 226.28 | 2 | 4 |
4 | 13 | 817.44 | 18 | 14.93 | 1511 | 406 | 2.91 / 226.68 | 2 | 3 |
5 | 13 | 326.04 | 18 | 15.09 | 806 | 219 | 3.13 / 226.90 | 2 | 3 |
6 | 13 | 37.56 | 18 | 15.16 | 357 | 97 | 3.22 / 227.00 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.12 | 301 | 751 | 3.97 / 227.75 | 2 | 12 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 31 | 15.10 | 453 | 212 | 0.21 / 219.93 | 2 | 2 |
2 | 7 | 2016.48 | 39 | 14.64 | 3050 | 1741 | 1.95 / 221.67 | 2 | 3 |
3 | 13 | 1410.32 | 18 | 14.77 | 2281 | 606 | 2.56 / 222.28 | 2 | 4 |
4 | 13 | 855.00 | 18 | 14.91 | 1552 | 417 | 2.98 / 222.70 | 2 | 3 |
5 | 13 | 366.08 | 18 | 15.07 | 865 | 235 | 3.21 / 222.93 | 2 | 3 |
6 | 13 | 33.24 | 18 | 15.16 | 353 | 96 | 3.31 / 223.03 | 2 | 9 |
7 | 8 | 0.04 | 165 | 15.14 | 300 | 749 | 4.06 / 223.78 | 2 | 7 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 31 | 15.09 | 463 | 217 | 0.22 / 215.95 | 2 | 2 |
2 | 7 | 2008.36 | 38 | 14.65 | 3037 | 1691 | 1.91 / 217.64 | 2 | 3 |
3 | 13 | 1328.76 | 18 | 14.79 | 2173 | 578 | 2.49 / 218.22 | 2 | 3 |
4 | 13 | 888.52 | 18 | 14.90 | 1597 | 428 | 2.91 / 218.64 | 2 | 4 |
5 | 13 | 341.28 | 18 | 15.08 | 832 | 226 | 3.14 / 218.87 | 2 | 3 |
6 | 13 | 48.44 | 18 | 15.16 | 372 | 102 | 3.24 / 218.97 | 2 | 5 |
7 | 8 | 0.04 | 165 | 15.14 | 300 | 749 | 3.99 / 219.72 | 2 | 15 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 31 | 15.10 | 439 | 205 | 0.21 / 211.96 | 2 | 2 |
2 | 7 | 2003.64 | 38 | 14.66 | 3035 | 1691 | 1.90 / 213.65 | 2 | 3 |
3 | 13 | 1339.96 | 18 | 14.80 | 2196 | 585 | 2.48 / 214.23 | 2 | 4 |
4 | 13 | 826.72 | 18 | 14.92 | 1515 | 407 | 2.89 / 214.64 | 2 | 3 |
5 | 13 | 351.80 | 18 | 15.09 | 844 | 229 | 3.12 / 214.87 | 2 | 3 |
6 | 13 | 54.32 | 18 | 15.17 | 390 | 106 | 3.22 / 214.98 | 2 | 5 |
7 | 8 | 0.12 | 165 | 15.13 | 302 | 754 | 3.98 / 215.73 | 2 | 4 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 31 | 15.10 | 452 | 212 | 0.21 / 207.97 | 2 | 2 |
2 | 7 | 2004.60 | 38 | 14.66 | 3029 | 1687 | 1.90 / 209.66 | 2 | 3 |
3 | 13 | 1314.60 | 18 | 14.81 | 2164 | 577 | 2.48 / 210.24 | 2 | 3 |
4 | 13 | 918.08 | 18 | 14.90 | 1634 | 438 | 2.91 / 210.67 | 2 | 3 |
5 | 13 | 321.36 | 18 | 15.10 | 797 | 217 | 3.13 / 210.89 | 2 | 3 |
6 | 13 | 73.72 | 18 | 15.17 | 410 | 112 | 3.24 / 211.00 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.14 | 300 | 749 | 3.99 / 211.75 | 2 | 19 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 31 | 15.11 | 439 | 206 | 0.21 / 203.92 | 2 | 2 |
2 | 7 | 2009.88 | 38 | 14.66 | 3036 | 1691 | 1.90 / 205.62 | 2 | 3 |
3 | 13 | 1408.76 | 18 | 14.79 | 2281 | 607 | 2.50 / 206.22 | 2 | 3 |
4 | 13 | 915.08 | 18 | 14.90 | 1638 | 439 | 2.94 / 206.66 | 2 | 3 |
5 | 13 | 411.84 | 18 | 15.06 | 930 | 252 | 3.20 / 206.91 | 2 | 3 |
6 | 13 | 48.88 | 18 | 15.17 | 373 | 102 | 3.30 / 207.02 | 2 | 7 |
7 | 8 | 0.04 | 165 | 15.14 | 298 | 744 | 4.04 / 207.76 | 2 | 15 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 31 | 15.10 | 451 | 211 | 0.21 / 199.87 | 2 | 2 |
2 | 7 | 2008.60 | 39 | 14.63 | 3041 | 1735 | 1.95 / 201.61 | 2 | 3 |
3 | 13 | 1405.24 | 18 | 14.78 | 2278 | 606 | 2.55 / 202.21 | 2 | 2 |
4 | 13 | 851.76 | 18 | 14.92 | 1544 | 415 | 2.97 / 202.63 | 2 | 3 |
5 | 13 | 363.12 | 18 | 15.08 | 866 | 235 | 3.20 / 202.86 | 2 | 3 |
6 | 13 | 58.04 | 18 | 15.17 | 391 | 107 | 3.31 / 202.97 | 2 | 6 |
7 | 8 | 0.12 | 165 | 15.15 | 299 | 747 | 4.06 / 203.72 | 2 | 3 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 31 | 15.10 | 440 | 206 | 0.21 / 195.87 | 2 | 2 |
2 | 7 | 2003.88 | 38 | 14.65 | 3029 | 1686 | 1.89 / 197.56 | 2 | 2 |
3 | 13 | 1382.44 | 18 | 14.79 | 2237 | 596 | 2.49 / 198.15 | 2 | 3 |
4 | 13 | 890.28 | 18 | 14.91 | 1596 | 428 | 2.92 / 198.58 | 2 | 3 |
5 | 13 | 379.92 | 18 | 15.08 | 875 | 238 | 3.15 / 198.82 | 2 | 3 |
6 | 13 | 37.68 | 18 | 15.18 | 358 | 98 | 3.25 / 198.92 | 2 | 6 |
7 | 8 | 0.04 | 165 | 15.15 | 298 | 745 | 4.00 / 199.66 | 2 | 2 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 31 | 15.11 | 447 | 209 | 0.21 / 191.85 | 2 | 2 |
2 | 7 | 2008.44 | 38 | 14.66 | 3035 | 1691 | 1.90 / 193.54 | 2 | 3 |
3 | 13 | 1458.80 | 18 | 14.78 | 2348 | 625 | 2.52 / 194.17 | 2 | 3 |
4 | 13 | 853.24 | 18 | 14.94 | 1555 | 418 | 2.94 / 194.59 | 2 | 3 |
5 | 13 | 349.20 | 18 | 15.09 | 841 | 228 | 3.17 / 194.82 | 2 | 3 |
6 | 13 | 47.36 | 18 | 15.18 | 373 | 102 | 3.27 / 194.92 | 2 | 6 |
7 | 8 | 0.16 | 165 | 15.14 | 300 | 749 | 4.02 / 195.67 | 2 | 2 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 31 | 15.12 | 451 | 211 | 0.21 / 187.82 | 2 | 2 |
2 | 7 | 2003.48 | 39 | 14.66 | 3033 | 1734 | 1.95 / 189.56 | 2 | 3 |
3 | 13 | 1377.16 | 18 | 14.81 | 2244 | 598 | 2.54 / 190.16 | 2 | 4 |
4 | 13 | 765.64 | 18 | 14.97 | 1435 | 387 | 2.93 / 190.54 | 2 | 3 |
5 | 13 | 372.40 | 18 | 15.09 | 886 | 241 | 3.17 / 190.78 | 2 | 3 |
6 | 13 | 40.16 | 18 | 15.19 | 367 | 100 | 3.27 / 190.88 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.15 | 304 | 760 | 4.03 / 191.64 | 2 | 3 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 31 | 15.12 | 438 | 205 | 0.21 / 183.81 | 2 | 2 |
2 | 7 | 2013.08 | 38 | 14.66 | 3047 | 1697 | 1.90 / 185.51 | 2 | 3 |
3 | 13 | 1301.72 | 18 | 14.82 | 2140 | 571 | 2.47 / 186.08 | 2 | 4 |
4 | 13 | 873.44 | 18 | 14.93 | 1578 | 424 | 2.90 / 186.50 | 2 | 3 |
5 | 13 | 407.60 | 18 | 15.07 | 930 | 252 | 3.15 / 186.75 | 2 | 3 |
6 | 13 | 41.84 | 18 | 15.19 | 370 | 101 | 3.25 / 186.85 | 2 | 7 |
7 | 8 | 0.08 | 165 | 15.15 | 303 | 757 | 4.01 / 187.61 | 2 | 3 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 31 | 15.13 | 454 | 213 | 0.21 / 179.80 | 2 | 2 |
2 | 7 | 2013.64 | 38 | 14.67 | 3053 | 1702 | 1.91 / 181.50 | 2 | 3 |
3 | 13 | 1398.80 | 18 | 14.81 | 2272 | 606 | 2.52 / 182.10 | 2 | 4 |
4 | 13 | 871.72 | 18 | 14.94 | 1575 | 424 | 2.94 / 182.53 | 2 | 3 |
5 | 13 | 321.88 | 18 | 15.13 | 805 | 219 | 3.16 / 182.75 | 2 | 3 |
6 | 13 | 39.48 | 18 | 15.20 | 365 | 100 | 3.26 / 182.85 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.17 | 303 | 758 | 4.02 / 183.60 | 2 | 12 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 31 | 15.13 | 444 | 208 | 0.21 / 175.80 | 2 | 2 |
2 | 7 | 2006.40 | 38 | 14.66 | 3034 | 1690 | 1.90 / 177.49 | 2 | 3 |
3 | 13 | 1336.48 | 18 | 14.82 | 2186 | 583 | 2.48 / 178.08 | 2 | 3 |
4 | 13 | 883.40 | 18 | 14.93 | 1594 | 428 | 2.91 / 178.51 | 2 | 3 |
5 | 13 | 325.72 | 18 | 15.12 | 809 | 220 | 3.13 / 178.73 | 2 | 3 |
6 | 13 | 36.08 | 18 | 15.20 | 359 | 98 | 3.23 / 178.82 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.16 | 303 | 758 | 3.99 / 179.58 | 2 | 9 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 31 | 15.13 | 433 | 203 | 0.20 / 171.83 | 2 | 2 |
2 | 7 | 2008.20 | 38 | 14.67 | 3042 | 1696 | 1.90 / 173.53 | 2 | 3 |
3 | 13 | 1353.76 | 18 | 14.82 | 2212 | 590 | 2.49 / 174.12 | 2 | 3 |
4 | 13 | 837.96 | 18 | 14.96 | 1528 | 411 | 2.90 / 174.53 | 2 | 3 |
5 | 13 | 305.84 | 18 | 15.13 | 774 | 211 | 3.11 / 174.74 | 2 | 3 |
6 | 13 | 34.16 | 18 | 15.21 | 355 | 97 | 3.21 / 174.84 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.18 | 302 | 756 | 3.96 / 175.60 | 2 | 11 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 31 | 15.14 | 464 | 218 | 0.22 / 167.86 | 2 | 2 |
2 | 7 | 2010.28 | 38 | 14.66 | 3037 | 1692 | 1.91 / 169.55 | 2 | 3 |
3 | 13 | 1337.04 | 18 | 14.82 | 2184 | 583 | 2.49 / 170.13 | 2 | 3 |
4 | 13 | 852.92 | 18 | 14.94 | 1560 | 420 | 2.91 / 170.55 | 2 | 3 |
5 | 13 | 352.48 | 18 | 15.11 | 854 | 232 | 3.14 / 170.78 | 2 | 3 |
6 | 13 | 24.08 | 18 | 15.20 | 338 | 92 | 3.24 / 170.88 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.17 | 302 | 756 | 3.99 / 171.63 | 2 | 6 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 31 | 15.15 | 435 | 204 | 0.20 / 163.87 | 2 | 2 |
2 | 7 | 2012.68 | 38 | 14.67 | 3044 | 1697 | 1.90 / 165.57 | 2 | 3 |
3 | 13 | 1331.92 | 18 | 14.83 | 2180 | 582 | 2.48 / 166.15 | 2 | 4 |
4 | 13 | 836.36 | 18 | 14.97 | 1521 | 410 | 2.89 / 166.56 | 2 | 4 |
5 | 13 | 370.52 | 18 | 15.11 | 870 | 237 | 3.13 / 166.79 | 2 | 3 |
6 | 13 | 29.88 | 18 | 15.21 | 344 | 94 | 3.22 / 166.89 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.17 | 300 | 751 | 3.97 / 167.64 | 2 | 8 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 31 | 15.15 | 450 | 211 | 0.21 / 159.90 | 2 | 2 |
2 | 7 | 2012.36 | 39 | 14.67 | 3058 | 1750 | 1.96 / 161.65 | 2 | 3 |
3 | 13 | 1394.48 | 18 | 14.82 | 2268 | 605 | 2.57 / 162.25 | 2 | 4 |
4 | 13 | 903.56 | 18 | 14.94 | 1619 | 435 | 3.00 / 162.69 | 2 | 3 |
5 | 13 | 342.36 | 18 | 15.13 | 832 | 227 | 3.23 / 162.91 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.19 | 300 | 752 | 3.98 / 163.66 | 2 | 6 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 31 | 15.15 | 451 | 212 | 0.21 / 155.99 | 2 | 2 |
2 | 7 | 2018.92 | 38 | 14.67 | 3052 | 1701 | 1.91 / 157.70 | 2 | 2 |
3 | 13 | 1334.60 | 18 | 14.83 | 2193 | 585 | 2.50 / 158.28 | 2 | 4 |
4 | 13 | 845.76 | 18 | 14.96 | 1537 | 414 | 2.91 / 158.69 | 2 | 3 |
5 | 13 | 346.20 | 18 | 15.12 | 838 | 228 | 3.14 / 158.92 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.18 | 304 | 761 | 3.90 / 159.68 | 2 | 13 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 31 | 15.16 | 437 | 205 | 0.21 / 152.11 | 2 | 2 |
2 | 7 | 2006.76 | 38 | 14.67 | 3045 | 1697 | 1.90 / 153.81 | 2 | 3 |
3 | 13 | 1352.84 | 18 | 14.83 | 2212 | 590 | 2.49 / 154.40 | 2 | 3 |
4 | 13 | 830.88 | 18 | 14.96 | 1518 | 409 | 2.90 / 154.81 | 2 | 4 |
5 | 13 | 333.36 | 18 | 15.12 | 815 | 222 | 3.12 / 155.03 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.20 | 300 | 752 | 3.88 / 155.78 | 2 | 13 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 31 | 15.18 | 445 | 209 | 0.21 / 148.23 | 2 | 3 |
2 | 7 | 2005.32 | 38 | 14.69 | 3032 | 1693 | 1.90 / 149.92 | 2 | 3 |
3 | 13 | 1394.00 | 18 | 14.83 | 2270 | 606 | 2.51 / 150.53 | 2 | 3 |
4 | 13 | 811.60 | 18 | 14.99 | 1498 | 404 | 2.91 / 150.93 | 2 | 3 |
5 | 13 | 323.12 | 18 | 15.14 | 800 | 218 | 3.13 / 151.15 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.21 | 301 | 755 | 3.89 / 151.91 | 2 | 8 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 31 | 15.17 | 448 | 211 | 0.21 / 144.27 | 2 | 2 |
2 | 7 | 2012.52 | 39 | 14.68 | 3049 | 1746 | 1.96 / 146.02 | 2 | 3 |
3 | 13 | 1336.16 | 18 | 14.86 | 2193 | 587 | 2.54 / 146.60 | 2 | 3 |
4 | 13 | 935.24 | 18 | 14.95 | 1667 | 449 | 2.99 / 147.05 | 2 | 4 |
5 | 13 | 318.40 | 18 | 15.15 | 790 | 215 | 3.21 / 147.27 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.20 | 300 | 752 | 3.96 / 148.02 | 2 | 3 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 31 | 15.17 | 436 | 205 | 0.21 / 140.22 | 2 | 2 |
2 | 7 | 2012.44 | 38 | 14.68 | 3053 | 1703 | 1.91 / 141.92 | 2 | 3 |
3 | 13 | 1385.24 | 18 | 14.85 | 2246 | 600 | 2.51 / 142.52 | 2 | 3 |
4 | 13 | 883.00 | 18 | 14.97 | 1591 | 429 | 2.94 / 142.95 | 2 | 3 |
5 | 13 | 333.60 | 18 | 15.14 | 813 | 222 | 3.16 / 143.17 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.21 | 300 | 753 | 3.91 / 143.93 | 2 | 17 |
7 | 14 | 0.16 | 30 | 15.19 | 297 | 135 | 4.05 / 144.06 | 3 | 12 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 31 | 15.17 | 440 | 207 | 0.21 / 136.32 | 2 | 2 |
2 | 7 | 2011.16 | 39 | 14.69 | 3041 | 1742 | 1.95 / 138.06 | 2 | 3 |
3 | 13 | 1324.16 | 18 | 14.86 | 2171 | 581 | 2.53 / 138.64 | 2 | 3 |
4 | 13 | 791.92 | 18 | 15.00 | 1468 | 396 | 2.93 / 139.04 | 2 | 3 |
5 | 13 | 350.72 | 18 | 15.14 | 844 | 230 | 3.16 / 139.27 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.21 | 297 | 745 | 3.90 / 140.01 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 31 | 15.17 | 445 | 209 | 0.21 / 132.34 | 2 | 2 |
2 | 7 | 2013.20 | 38 | 14.69 | 3042 | 1698 | 1.91 / 134.03 | 2 | 3 |
3 | 13 | 1317.24 | 18 | 14.86 | 2166 | 579 | 2.49 / 134.61 | 2 | 3 |
4 | 13 | 875.76 | 18 | 14.97 | 1580 | 426 | 2.91 / 135.04 | 2 | 3 |
5 | 13 | 362.52 | 18 | 15.13 | 861 | 234 | 3.15 / 135.27 | 2 | 3 |
6 | 13 | 22.52 | 18 | 15.24 | 337 | 92 | 3.24 / 135.37 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.20 | 298 | 747 | 3.99 / 136.11 | 2 | 3 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.36 | 31 | 15.17 | 459 | 216 | 0.22 / 128.43 | 2 | 3 |
2 | 7 | 2012.24 | 38 | 14.68 | 3037 | 1694 | 1.91 / 130.13 | 2 | 2 |
3 | 13 | 1383.16 | 18 | 14.84 | 2251 | 601 | 2.51 / 130.73 | 2 | 3 |
4 | 13 | 844.68 | 18 | 14.98 | 1537 | 414 | 2.93 / 131.14 | 2 | 3 |
5 | 13 | 345.12 | 18 | 15.14 | 832 | 227 | 3.15 / 131.37 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.21 | 301 | 755 | 3.91 / 132.13 | 2 | 7 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.96 | 31 | 15.18 | 468 | 220 | 0.22 / 124.49 | 2 | 2 |
2 | 7 | 2009.28 | 39 | 14.70 | 3041 | 1743 | 1.96 / 126.23 | 2 | 3 |
3 | 13 | 1357.96 | 18 | 14.86 | 2216 | 593 | 2.56 / 126.82 | 2 | 3 |
4 | 13 | 821.60 | 18 | 15.00 | 1506 | 407 | 2.96 / 127.23 | 2 | 4 |
5 | 13 | 363.80 | 18 | 15.15 | 856 | 233 | 3.20 / 127.47 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.21 | 300 | 753 | 3.95 / 128.22 | 2 | 7 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 31 | 15.18 | 446 | 210 | 0.21 / 120.55 | 2 | 2 |
2 | 7 | 2004.00 | 38 | 14.70 | 3037 | 1696 | 1.91 / 122.24 | 2 | 3 |
3 | 13 | 1356.64 | 18 | 14.86 | 2217 | 593 | 2.50 / 122.84 | 2 | 3 |
4 | 13 | 898.84 | 18 | 14.97 | 1614 | 435 | 2.93 / 123.27 | 2 | 4 |
5 | 13 | 371.32 | 18 | 15.14 | 869 | 237 | 3.17 / 123.51 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.21 | 303 | 760 | 3.93 / 124.27 | 2 | 5 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 30 | 15.20 | 459 | 209 | 0.21 / 116.68 | 2 | 2 |
2 | 7 | 2005.96 | 38 | 14.71 | 3032 | 1695 | 1.90 / 118.37 | 2 | 3 |
3 | 13 | 1332.52 | 18 | 14.88 | 2184 | 585 | 2.49 / 118.96 | 2 | 3 |
4 | 13 | 844.36 | 18 | 14.99 | 1535 | 414 | 2.90 / 119.37 | 2 | 3 |
5 | 13 | 324.32 | 18 | 15.17 | 802 | 219 | 3.12 / 119.59 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.23 | 297 | 746 | 3.87 / 120.34 | 2 | 4 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 30 | 15.19 | 462 | 211 | 0.21 / 112.75 | 2 | 2 |
2 | 7 | 2006.88 | 39 | 14.70 | 3029 | 1737 | 1.95 / 114.49 | 2 | 2 |
3 | 13 | 1345.44 | 18 | 14.87 | 2195 | 588 | 2.53 / 115.07 | 2 | 3 |
4 | 13 | 852.56 | 18 | 14.99 | 1549 | 418 | 2.95 / 115.49 | 2 | 3 |
5 | 13 | 345.24 | 18 | 15.16 | 833 | 227 | 3.18 / 115.72 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.23 | 298 | 749 | 3.93 / 116.47 | 2 | 3 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 30 | 15.19 | 439 | 200 | 0.20 / 108.71 | 2 | 2 |
2 | 7 | 2004.72 | 38 | 14.71 | 3042 | 1700 | 1.90 / 110.41 | 2 | 3 |
3 | 13 | 1440.16 | 18 | 14.85 | 2329 | 623 | 2.52 / 111.03 | 2 | 3 |
4 | 13 | 833.64 | 18 | 15.00 | 1527 | 412 | 2.94 / 111.44 | 2 | 3 |
5 | 13 | 336.48 | 18 | 15.17 | 822 | 224 | 3.16 / 111.67 | 2 | 3 |
6 | 13 | 80.48 | 18 | 15.25 | 424 | 116 | 3.28 / 111.78 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.23 | 301 | 756 | 4.03 / 112.54 | 2 | 5 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 30 | 15.19 | 468 | 213 | 0.21 / 104.84 | 2 | 2 |
2 | 7 | 2011.56 | 38 | 14.71 | 3041 | 1700 | 1.91 / 106.54 | 2 | 2 |
3 | 13 | 1397.44 | 18 | 14.87 | 2261 | 605 | 2.52 / 107.14 | 2 | 3 |
4 | 13 | 844.08 | 18 | 15.00 | 1541 | 416 | 2.93 / 107.56 | 2 | 3 |
5 | 13 | 262.88 | 18 | 15.19 | 700 | 191 | 3.13 / 107.75 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.23 | 301 | 756 | 3.88 / 108.51 | 2 | 7 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 30 | 15.20 | 452 | 206 | 0.21 / 100.91 | 2 | 2 |
2 | 7 | 2003.48 | 38 | 14.71 | 3046 | 1703 | 1.91 / 102.62 | 2 | 3 |
3 | 13 | 1352.68 | 18 | 14.88 | 2219 | 594 | 2.50 / 103.21 | 2 | 3 |
4 | 13 | 897.60 | 18 | 14.99 | 1612 | 435 | 2.94 / 103.65 | 2 | 3 |
5 | 13 | 324.56 | 18 | 15.17 | 810 | 221 | 3.16 / 103.87 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.22 | 302 | 758 | 3.92 / 104.63 | 2 | 6 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 30 | 15.20 | 444 | 202 | 0.20 / 96.98 | 2 | 2 |
2 | 7 | 2004.72 | 38 | 14.72 | 3037 | 1699 | 1.90 / 98.68 | 2 | 2 |
3 | 13 | 1440.32 | 18 | 14.86 | 2333 | 624 | 2.53 / 99.30 | 2 | 3 |
4 | 13 | 890.40 | 18 | 15.00 | 1607 | 434 | 2.96 / 99.74 | 2 | 3 |
5 | 13 | 294.76 | 18 | 15.19 | 762 | 208 | 3.17 / 99.95 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.23 | 303 | 761 | 3.93 / 100.71 | 2 | 5 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 30 | 15.20 | 445 | 203 | 0.20 / 93.04 | 2 | 2 |
2 | 7 | 2006.20 | 38 | 14.73 | 3046 | 1705 | 1.91 / 94.75 | 2 | 3 |
3 | 13 | 1316.44 | 18 | 14.91 | 2183 | 586 | 2.49 / 95.33 | 2 | 3 |
4 | 13 | 892.44 | 18 | 15.01 | 1613 | 436 | 2.93 / 95.77 | 2 | 3 |
5 | 13 | 374.36 | 18 | 15.17 | 894 | 244 | 3.17 / 96.01 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.24 | 304 | 764 | 3.94 / 96.78 | 2 | 10 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.48 | 30 | 15.20 | 463 | 211 | 0.21 / 89.08 | 2 | 2 |
2 | 7 | 2003.72 | 38 | 14.72 | 3042 | 1702 | 1.91 / 90.78 | 2 | 2 |
3 | 13 | 1474.92 | 18 | 14.86 | 2370 | 634 | 2.55 / 91.42 | 2 | 4 |
4 | 13 | 845.84 | 18 | 15.01 | 1548 | 418 | 2.96 / 91.84 | 2 | 3 |
5 | 13 | 382.36 | 18 | 15.16 | 897 | 245 | 3.21 / 92.08 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.23 | 302 | 759 | 3.97 / 92.84 | 2 | 7 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 30 | 15.21 | 443 | 202 | 0.20 / 85.24 | 2 | 2 |
2 | 7 | 2011.64 | 38 | 14.73 | 3052 | 1708 | 1.91 / 86.95 | 2 | 3 |
3 | 13 | 1283.76 | 18 | 14.92 | 2128 | 571 | 2.48 / 87.52 | 2 | 3 |
4 | 13 | 773.04 | 18 | 15.05 | 1450 | 393 | 2.87 / 87.91 | 2 | 3 |
5 | 13 | 291.72 | 18 | 15.21 | 751 | 206 | 3.08 / 88.11 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.24 | 301 | 757 | 3.84 / 88.87 | 2 | 5 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 30 | 15.21 | 441 | 201 | 0.20 / 81.32 | 2 | 2 |
2 | 7 | 2013.00 | 38 | 14.72 | 3048 | 1705 | 1.91 / 83.03 | 2 | 3 |
3 | 13 | 1433.00 | 18 | 14.89 | 2325 | 623 | 2.53 / 83.65 | 2 | 3 |
4 | 13 | 794.64 | 18 | 15.05 | 1477 | 400 | 2.93 / 84.05 | 2 | 4 |
5 | 13 | 341.28 | 18 | 15.19 | 833 | 228 | 3.16 / 84.28 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.24 | 301 | 757 | 3.91 / 85.03 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.00 | 30 | 15.22 | 464 | 212 | 0.21 / 77.32 | 2 | 2 |
2 | 7 | 2011.16 | 38 | 14.75 | 3058 | 1714 | 1.93 / 79.04 | 2 | 3 |
3 | 13 | 1306.72 | 18 | 14.92 | 2158 | 580 | 2.51 / 79.62 | 2 | 3 |
4 | 13 | 815.44 | 18 | 15.04 | 1512 | 409 | 2.91 / 80.03 | 2 | 3 |
5 | 13 | 312.16 | 18 | 15.20 | 792 | 217 | 3.13 / 80.24 | 2 | 3 |
6 | 13 | 64.36 | 18 | 15.26 | 409 | 112 | 3.24 / 80.36 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.23 | 304 | 764 | 4.01 / 81.12 | 2 | 8 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 30 | 15.22 | 439 | 200 | 0.20 / 73.46 | 2 | 2 |
2 | 7 | 2008.00 | 38 | 14.73 | 3054 | 1709 | 1.91 / 75.17 | 2 | 3 |
3 | 13 | 1292.60 | 18 | 14.94 | 2142 | 576 | 2.49 / 75.75 | 2 | 3 |
4 | 13 | 779.52 | 18 | 15.06 | 1460 | 396 | 2.88 / 76.15 | 2 | 4 |
5 | 13 | 294.88 | 18 | 15.21 | 757 | 207 | 3.09 / 76.35 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.25 | 302 | 760 | 3.85 / 77.11 | 2 | 6 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 30 | 15.21 | 446 | 204 | 0.20 / 69.46 | 2 | 2 |
2 | 7 | 2006.60 | 38 | 14.74 | 3052 | 1709 | 1.91 / 71.17 | 2 | 3 |
3 | 13 | 1366.92 | 18 | 14.90 | 2239 | 600 | 2.51 / 71.77 | 2 | 3 |
4 | 13 | 792.28 | 18 | 15.06 | 1481 | 401 | 2.91 / 72.17 | 2 | 3 |
5 | 13 | 349.44 | 18 | 15.20 | 850 | 233 | 3.15 / 72.40 | 2 | 3 |
6 | 13 | 20.80 | 18 | 15.28 | 341 | 94 | 3.24 / 72.50 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.26 | 304 | 765 | 4.01 / 73.26 | 2 | 8 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 30 | 15.22 | 466 | 213 | 0.21 / 65.48 | 2 | 2 |
2 | 7 | 2004.64 | 38 | 14.75 | 3042 | 1705 | 1.92 / 67.19 | 2 | 3 |
3 | 13 | 1336.52 | 18 | 14.92 | 2211 | 594 | 2.51 / 67.78 | 2 | 3 |
4 | 13 | 827.12 | 18 | 15.04 | 1523 | 412 | 2.92 / 68.19 | 2 | 3 |
5 | 13 | 314.72 | 18 | 15.21 | 791 | 217 | 3.14 / 68.41 | 2 | 3 |
6 | 13 | 14.00 | 18 | 15.28 | 324 | 89 | 3.23 / 68.50 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.25 | 301 | 757 | 3.99 / 69.26 | 2 | 6 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 30 | 15.21 | 443 | 202 | 0.20 / 61.50 | 2 | 2 |
2 | 7 | 2004.00 | 38 | 14.74 | 3038 | 1702 | 1.90 / 63.20 | 2 | 2 |
3 | 13 | 1375.16 | 18 | 14.91 | 2252 | 604 | 2.51 / 63.81 | 2 | 3 |
4 | 13 | 751.68 | 18 | 15.07 | 1427 | 387 | 2.90 / 64.19 | 2 | 3 |
5 | 13 | 309.76 | 18 | 15.21 | 784 | 215 | 3.11 / 64.41 | 2 | 3 |
6 | 13 | 44.44 | 18 | 15.27 | 373 | 103 | 3.21 / 64.51 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.25 | 302 | 760 | 3.97 / 65.27 | 2 | 11 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 30 | 15.23 | 436 | 199 | 0.20 / 57.51 | 2 | 2 |
2 | 7 | 2010.48 | 38 | 14.74 | 3065 | 1717 | 1.92 / 59.23 | 2 | 3 |
3 | 13 | 1316.72 | 18 | 14.93 | 2174 | 584 | 2.50 / 59.81 | 2 | 3 |
4 | 13 | 787.92 | 18 | 15.05 | 1469 | 398 | 2.90 / 60.21 | 2 | 3 |
5 | 13 | 337.28 | 18 | 15.20 | 827 | 226 | 3.12 / 60.44 | 2 | 3 |
6 | 13 | 35.40 | 18 | 15.27 | 359 | 99 | 3.22 / 60.54 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.24 | 303 | 762 | 3.99 / 61.30 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 30 | 15.22 | 448 | 205 | 0.20 / 53.58 | 2 | 2 |
2 | 7 | 2004.92 | 38 | 14.77 | 3050 | 1712 | 1.92 / 55.29 | 2 | 2 |
3 | 13 | 1268.48 | 18 | 14.95 | 2112 | 568 | 2.48 / 55.86 | 2 | 3 |
4 | 13 | 773.76 | 18 | 15.07 | 1457 | 395 | 2.88 / 56.25 | 2 | 3 |
5 | 13 | 286.24 | 18 | 15.23 | 746 | 205 | 3.08 / 56.46 | 2 | 3 |
6 | 13 | 35.00 | 18 | 15.30 | 352 | 97 | 3.18 / 56.56 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.25 | 301 | 757 | 3.94 / 57.31 | 2 | 6 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 30 | 15.23 | 453 | 207 | 0.21 / 49.61 | 2 | 2 |
2 | 7 | 2003.36 | 38 | 14.76 | 3050 | 1711 | 1.92 / 51.32 | 2 | 3 |
3 | 13 | 1278.00 | 18 | 14.94 | 2126 | 572 | 2.49 / 51.89 | 2 | 3 |
4 | 13 | 793.72 | 18 | 15.07 | 1479 | 401 | 2.89 / 52.29 | 2 | 3 |
5 | 13 | 328.20 | 18 | 15.21 | 814 | 223 | 3.11 / 52.51 | 2 | 3 |
6 | 13 | 35.24 | 18 | 15.30 | 355 | 98 | 3.21 / 52.61 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.26 | 303 | 763 | 3.97 / 53.37 | 2 | 6 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 30 | 15.23 | 453 | 207 | 0.21 / 45.57 | 2 | 2 |
2 | 7 | 2006.60 | 38 | 14.78 | 3050 | 1713 | 1.92 / 47.28 | 2 | 2 |
3 | 13 | 1396.16 | 18 | 14.92 | 2283 | 613 | 2.53 / 47.90 | 2 | 3 |
4 | 13 | 803.76 | 18 | 15.08 | 1492 | 405 | 2.94 / 48.30 | 2 | 3 |
5 | 13 | 347.40 | 18 | 15.22 | 847 | 232 | 3.17 / 48.53 | 2 | 3 |
6 | 13 | 43.92 | 18 | 15.29 | 371 | 102 | 3.27 / 48.64 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.27 | 303 | 763 | 4.04 / 49.40 | 2 | 6 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 30 | 15.25 | 440 | 201 | 0.20 / 41.56 | 2 | 2 |
2 | 7 | 2003.52 | 39 | 14.77 | 3041 | 1752 | 1.95 / 43.31 | 2 | 3 |
3 | 13 | 1355.20 | 18 | 14.93 | 2224 | 598 | 2.55 / 43.91 | 2 | 3 |
4 | 13 | 730.84 | 18 | 15.09 | 1399 | 380 | 2.93 / 44.29 | 2 | 3 |
5 | 13 | 295.80 | 18 | 15.23 | 765 | 210 | 3.14 / 44.50 | 2 | 3 |
6 | 13 | 39.16 | 18 | 15.30 | 365 | 101 | 3.24 / 44.60 | 2 | 2 |
7 | 8 | -0.12 | 165 | 15.27 | 303 | 763 | 4.00 / 45.36 | 2 | 7 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 29 | 15.23 | 464 | 205 | 0.20 / 37.76 | 2 | 2 |
2 | 7 | 2011.24 | 38 | 14.79 | 3054 | 1716 | 1.92 / 39.47 | 2 | 2 |
3 | 13 | 1212.72 | 18 | 14.98 | 2045 | 551 | 2.47 / 40.02 | 2 | 3 |
4 | 13 | 786.12 | 18 | 15.09 | 1466 | 398 | 2.87 / 40.42 | 2 | 3 |
5 | 13 | 246.20 | 18 | 15.26 | 680 | 187 | 3.06 / 40.61 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.29 | 298 | 752 | 3.81 / 41.36 | 2 | 6 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 29 | 15.24 | 468 | 207 | 0.21 / 33.77 | 2 | 2 |
2 | 7 | 2007.12 | 38 | 14.78 | 3054 | 1715 | 1.92 / 35.48 | 2 | 2 |
3 | 13 | 1292.20 | 18 | 14.97 | 2143 | 577 | 2.50 / 36.06 | 2 | 3 |
4 | 13 | 834.16 | 18 | 15.07 | 1536 | 417 | 2.92 / 36.47 | 2 | 3 |
5 | 13 | 356.32 | 18 | 15.23 | 857 | 235 | 3.15 / 36.71 | 2 | 3 |
6 | 13 | 23.80 | 18 | 15.31 | 336 | 93 | 3.24 / 36.80 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.27 | 297 | 748 | 3.99 / 37.55 | 2 | 6 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 29 | 15.24 | 441 | 195 | 0.19 / 29.80 | 2 | 2 |
2 | 7 | 2003.64 | 38 | 14.79 | 3045 | 1711 | 1.91 / 31.51 | 2 | 3 |
3 | 13 | 1329.20 | 18 | 14.95 | 2187 | 589 | 2.49 / 32.10 | 2 | 3 |
4 | 13 | 790.00 | 18 | 15.09 | 1475 | 401 | 2.90 / 32.50 | 2 | 4 |
5 | 13 | 289.16 | 18 | 15.24 | 754 | 207 | 3.10 / 32.71 | 2 | 3 |
6 | 13 | 19.52 | 18 | 15.32 | 338 | 93 | 3.20 / 32.80 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.28 | 301 | 759 | 3.95 / 33.56 | 2 | 6 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 29 | 15.25 | 467 | 207 | 0.21 / 25.84 | 2 | 2 |
2 | 7 | 2003.84 | 38 | 14.79 | 3044 | 1711 | 1.92 / 27.55 | 2 | 3 |
3 | 13 | 1334.92 | 18 | 14.96 | 2189 | 589 | 2.51 / 28.14 | 2 | 3 |
4 | 13 | 748.60 | 18 | 15.10 | 1415 | 385 | 2.89 / 28.52 | 2 | 3 |
5 | 13 | 303.84 | 18 | 15.23 | 776 | 213 | 3.10 / 28.74 | 2 | 3 |
6 | 13 | 40.00 | 18 | 15.30 | 367 | 101 | 3.21 / 28.84 | 2 | 2 |
7 | 8 | -0.24 | 165 | 15.27 | 304 | 766 | 3.97 / 29.60 | 2 | 8 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.88 | 27 | 15.26 | 469 | 193 | 0.19 / 21.07 | 2 | 2 |
2 | 3 | 1053.04 | 2 | 15.24 | 1874 | 57 | 0.25 / 21.13 | 2 | 2 |
3 | 7 | 2012.52 | 74 | 14.67 | 3042 | 3302 | 3.55 / 24.43 | 2 | 3 |
4 | 13 | 537.28 | 18 | 15.16 | 1117 | 305 | 3.86 / 24.74 | 2 | 3 |
5 | 13 | 111.32 | 18 | 15.29 | 477 | 131 | 3.99 / 24.87 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.28 | 303 | 764 | 4.75 / 25.63 | 2 | 6 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 29 | 15.26 | 470 | 208 | 0.21 / 16.40 | 2 | 2 |
2 | 3 | 955.80 | -1 | 15.62 | 0 | 0 | 0.00 / 16.40 | 2 | 2 |
3 | 7 | 2007.96 | 74 | 14.68 | 3036 | 3298 | 3.51 / 19.70 | 2 | 3 |
4 | 13 | 503.84 | 18 | 15.19 | 1065 | 291 | 3.80 / 19.99 | 2 | 3 |
5 | 13 | 94.80 | 18 | 15.32 | 449 | 124 | 3.92 / 20.11 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.28 | 304 | 766 | 4.69 / 20.88 | 2 | 8 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 27 | 15.23 | 465 | 191 | 0.19 / 12.46 | 2 | 2 |
2 | 3 | 1016.08 | 1 | 15.29 | 1817 | 28 | 0.22 / 12.49 | 2 | 2 |
3 | 7 | 1510.92 | 74 | 14.88 | 2393 | 2635 | 2.85 / 15.12 | 2 | 3 |
4 | 13 | 280.92 | 18 | 15.26 | 736 | 202 | 3.06 / 15.32 | 2 | 3 |
5 | 13 | 27.08 | 18 | 15.32 | 354 | 98 | 3.15 / 15.42 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.29 | 306 | 772 | 3.93 / 16.19 | 2 | 7 |
Average= | 3.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 26 | 15.25 | 454 | 180 | 0.18 / 8.48 | 2 | 2 |
2 | 3 | 1053.28 | 2 | 15.21 | 1896 | 58 | 0.24 / 8.54 | 2 | 2 |
3 | 7 | 1520.52 | 74 | 14.87 | 2409 | 2651 | 2.89 / 11.19 | 2 | 3 |
4 | 13 | 290.44 | 18 | 15.26 | 753 | 207 | 3.10 / 11.39 | 2 | 3 |
5 | 13 | 27.56 | 18 | 15.32 | 355 | 98 | 3.19 / 11.49 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.28 | 307 | 774 | 3.97 / 12.27 | 2 | 7 |
Average= | 3.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 31 | 15.26 | 455 | 215 | 0.22 / 4.64 | 2 | 2 |
2 | 3 | 830.12 | -3 | 15.63 | 0 | 0 | 0.00 / 4.64 | 2 | 2 |
3 | 3 | 940.64 | -1 | 15.65 | 0 | 0 | 0.00 / 4.64 | 2 | 2 |
4 | 7 | 1525.48 | 75 | 14.88 | 2408 | 2687 | 2.90 / 7.33 | 2 | 3 |
5 | 13 | 278.24 | 18 | 15.26 | 735 | 202 | 3.10 / 7.53 | 2 | 3 |
6 | 8 | 0.36 | 165 | 15.28 | 305 | 769 | 3.87 / 8.30 | 2 | 5 |
Average= | 2.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 26 | 15.47 | 425 | 171 | 0.17 / 1.72 | 3 | 3 |
2 | 7 | 1006.64 | 74 | 15.08 | 1718 | 1917 | 2.09 / 3.64 | 2 | 3 |
3 | 8 | -0.08 | 165 | 15.32 | 311 | 786 | 2.87 / 4.43 | 2 | 7 |
Average= | 2.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 78.84 | 26 | 15.62 | 347 | 141 | 0.14 / 0.14 | 3 | 3 |
2 | 7 | 94.92 | 74 | 15.58 | 399 | 460 | 0.60 / 0.60 | 3 | 3 |
3 | 8 | 0.40 | 240 | 15.54 | 255 | 951 | 1.55 / 1.55 | 3 | 9 |
Average= | 1.55 (KJ/cycle) |