SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 31 | 15.07 | 437 | 204 | 0.20 / 279.11 | 2 | 3 |
2 | 7 | 2012.60 | 38 | 14.72 | 2966 | 1659 | 1.86 / 280.77 | 2 | 2 |
3 | 13 | 1402.28 | 18 | 14.81 | 2221 | 592 | 2.46 / 281.37 | 2 | 3 |
4 | 13 | 904.72 | 18 | 14.91 | 1578 | 424 | 2.88 / 281.79 | 2 | 3 |
5 | 13 | 398.88 | 18 | 15.04 | 890 | 241 | 3.12 / 282.03 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.12 | 287 | 716 | 3.84 / 282.75 | 2 | 3 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 31 | 15.06 | 456 | 213 | 0.21 / 275.28 | 3 | 3 |
2 | 7 | 2002.60 | 38 | 14.72 | 2948 | 1649 | 1.86 / 276.93 | 2 | 2 |
3 | 13 | 1438.12 | 18 | 14.81 | 2258 | 602 | 2.46 / 277.53 | 2 | 3 |
4 | 13 | 859.40 | 18 | 14.91 | 1514 | 406 | 2.87 / 277.94 | 2 | 3 |
5 | 13 | 412.96 | 18 | 15.03 | 914 | 247 | 3.12 / 278.18 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.11 | 292 | 728 | 3.85 / 278.91 | 2 | 5 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 31 | 15.07 | 431 | 201 | 0.20 / 271.34 | 2 | 3 |
2 | 7 | 2014.28 | 38 | 14.73 | 2966 | 1660 | 1.86 / 273.00 | 2 | 3 |
3 | 13 | 1433.44 | 18 | 14.81 | 2255 | 601 | 2.46 / 273.60 | 2 | 3 |
4 | 13 | 854.76 | 18 | 14.92 | 1503 | 404 | 2.87 / 274.01 | 2 | 3 |
5 | 13 | 371.44 | 18 | 15.06 | 848 | 230 | 3.10 / 274.24 | 2 | 3 |
6 | 13 | 15.08 | 18 | 15.14 | 321 | 87 | 3.18 / 274.32 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.10 | 297 | 740 | 3.92 / 275.06 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 31 | 15.09 | 449 | 210 | 0.21 / 267.47 | 2 | 3 |
2 | 7 | 2010.72 | 39 | 14.72 | 2963 | 1701 | 1.91 / 269.17 | 2 | 3 |
3 | 13 | 1373.56 | 18 | 14.82 | 2182 | 582 | 2.49 / 269.75 | 2 | 3 |
4 | 13 | 846.76 | 18 | 14.92 | 1499 | 403 | 2.90 / 270.15 | 2 | 3 |
5 | 13 | 436.32 | 18 | 15.04 | 951 | 257 | 3.15 / 270.41 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.11 | 293 | 730 | 3.88 / 271.14 | 2 | 3 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 31 | 15.08 | 458 | 214 | 0.21 / 263.60 | 3 | 3 |
2 | 7 | 2013.72 | 38 | 14.74 | 2977 | 1667 | 1.88 / 265.27 | 2 | 3 |
3 | 13 | 1423.20 | 18 | 14.81 | 2251 | 600 | 2.48 / 265.87 | 2 | 3 |
4 | 13 | 840.56 | 18 | 14.94 | 1497 | 403 | 2.88 / 266.27 | 2 | 3 |
5 | 13 | 402.84 | 18 | 15.06 | 901 | 244 | 3.13 / 266.52 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.13 | 296 | 739 | 3.87 / 267.26 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 31 | 15.09 | 444 | 208 | 0.21 / 259.76 | 2 | 3 |
2 | 7 | 2006.52 | 38 | 14.73 | 2964 | 1659 | 1.87 / 261.42 | 2 | 3 |
3 | 13 | 1386.64 | 18 | 14.81 | 2204 | 588 | 2.45 / 262.01 | 2 | 3 |
4 | 13 | 816.80 | 18 | 14.94 | 1466 | 394 | 2.85 / 262.40 | 2 | 3 |
5 | 13 | 425.84 | 18 | 15.05 | 933 | 253 | 3.10 / 262.66 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.13 | 294 | 734 | 3.84 / 263.39 | 2 | 3 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 31 | 15.09 | 440 | 206 | 0.21 / 255.90 | 2 | 3 |
2 | 7 | 2005.56 | 38 | 14.73 | 2970 | 1662 | 1.87 / 257.57 | 2 | 2 |
3 | 13 | 1403.12 | 18 | 14.81 | 2220 | 592 | 2.46 / 258.16 | 2 | 3 |
4 | 13 | 894.40 | 18 | 14.93 | 1568 | 421 | 2.88 / 258.58 | 2 | 3 |
5 | 13 | 395.08 | 18 | 15.06 | 886 | 240 | 3.12 / 258.82 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.13 | 295 | 736 | 3.86 / 259.56 | 2 | 7 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 31 | 15.09 | 450 | 211 | 0.21 / 252.13 | 2 | 3 |
2 | 7 | 2010.04 | 38 | 14.73 | 2963 | 1659 | 1.87 / 253.79 | 2 | 2 |
3 | 13 | 1329.52 | 18 | 14.83 | 2130 | 569 | 2.44 / 254.35 | 2 | 2 |
4 | 13 | 791.76 | 18 | 14.95 | 1429 | 385 | 2.82 / 254.74 | 2 | 3 |
5 | 13 | 356.36 | 18 | 15.08 | 834 | 226 | 3.05 / 254.97 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.13 | 293 | 731 | 3.78 / 255.70 | 2 | 4 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 31 | 15.10 | 443 | 207 | 0.21 / 248.30 | 3 | 3 |
2 | 7 | 2005.36 | 38 | 14.73 | 2955 | 1654 | 1.86 / 249.96 | 2 | 3 |
3 | 13 | 1425.60 | 18 | 14.82 | 2252 | 601 | 2.46 / 250.56 | 2 | 3 |
4 | 13 | 788.20 | 18 | 14.97 | 1425 | 384 | 2.85 / 250.94 | 2 | 3 |
5 | 13 | 405.24 | 18 | 15.07 | 902 | 245 | 3.09 / 251.19 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.14 | 293 | 732 | 3.82 / 251.92 | 2 | 8 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 31 | 15.10 | 436 | 204 | 0.20 / 244.54 | 3 | 3 |
2 | 7 | 2005.00 | 38 | 14.74 | 2966 | 1661 | 1.87 / 246.20 | 2 | 3 |
3 | 13 | 1284.24 | 18 | 14.87 | 2069 | 554 | 2.42 / 246.76 | 2 | 3 |
4 | 13 | 816.92 | 18 | 14.95 | 1457 | 392 | 2.81 / 247.15 | 2 | 3 |
5 | 13 | 343.16 | 18 | 15.08 | 817 | 222 | 3.03 / 247.37 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.14 | 290 | 724 | 3.76 / 248.09 | 2 | 6 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 31 | 15.10 | 448 | 210 | 0.21 / 240.69 | 3 | 3 |
2 | 7 | 2003.52 | 38 | 14.74 | 2962 | 1659 | 1.87 / 242.35 | 2 | 3 |
3 | 13 | 1368.28 | 18 | 14.84 | 2174 | 581 | 2.45 / 242.93 | 2 | 3 |
4 | 13 | 925.28 | 18 | 14.93 | 1603 | 431 | 2.88 / 243.36 | 2 | 3 |
5 | 13 | 374.00 | 18 | 15.08 | 858 | 233 | 3.11 / 243.60 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.14 | 296 | 739 | 3.85 / 244.34 | 2 | 7 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.24 | 31 | 15.11 | 451 | 211 | 0.21 / 236.77 | 2 | 3 |
2 | 7 | 2004.20 | 38 | 14.74 | 2951 | 1653 | 1.86 / 238.42 | 2 | 3 |
3 | 13 | 1491.44 | 18 | 14.82 | 2329 | 621 | 2.49 / 239.04 | 2 | 3 |
4 | 13 | 810.52 | 18 | 14.98 | 1448 | 390 | 2.88 / 239.43 | 2 | 3 |
5 | 13 | 378.72 | 18 | 15.09 | 867 | 235 | 3.11 / 239.67 | 2 | 3 |
6 | 13 | 19.92 | 18 | 15.18 | 327 | 89 | 3.20 / 239.76 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.15 | 291 | 727 | 3.93 / 240.48 | 2 | 4 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 31 | 15.10 | 439 | 205 | 0.21 / 232.95 | 2 | 3 |
2 | 7 | 2009.28 | 38 | 14.73 | 2964 | 1659 | 1.86 / 234.61 | 2 | 2 |
3 | 13 | 1395.48 | 18 | 14.85 | 2211 | 591 | 2.46 / 235.20 | 2 | 3 |
4 | 13 | 812.40 | 18 | 14.97 | 1451 | 391 | 2.85 / 235.59 | 2 | 3 |
5 | 13 | 370.40 | 18 | 15.09 | 851 | 231 | 3.08 / 235.82 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.15 | 295 | 737 | 3.82 / 236.56 | 2 | 9 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 31 | 15.10 | 456 | 213 | 0.21 / 229.04 | 3 | 3 |
2 | 7 | 2010.44 | 38 | 14.75 | 2964 | 1661 | 1.87 / 230.70 | 2 | 3 |
3 | 13 | 1363.76 | 18 | 14.85 | 2175 | 581 | 2.46 / 231.28 | 2 | 3 |
4 | 13 | 837.88 | 18 | 14.97 | 1486 | 400 | 2.86 / 231.68 | 2 | 3 |
5 | 13 | 355.48 | 18 | 15.11 | 829 | 225 | 3.08 / 231.91 | 2 | 3 |
6 | 13 | 57.24 | 18 | 15.18 | 376 | 103 | 3.18 / 232.01 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.15 | 292 | 730 | 3.91 / 232.74 | 2 | 6 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 31 | 15.12 | 438 | 205 | 0.21 / 225.17 | 3 | 3 |
2 | 7 | 2003.84 | 38 | 14.74 | 2954 | 1655 | 1.86 / 226.83 | 2 | 2 |
3 | 13 | 1284.72 | 18 | 14.87 | 2066 | 553 | 2.41 / 227.38 | 2 | 3 |
4 | 13 | 855.16 | 18 | 14.95 | 1505 | 405 | 2.82 / 227.79 | 2 | 3 |
5 | 13 | 359.80 | 18 | 15.10 | 837 | 227 | 3.05 / 228.01 | 2 | 3 |
6 | 13 | 20.76 | 18 | 15.19 | 324 | 89 | 3.13 / 228.10 | 2 | 4 |
7 | 8 | 0.20 | 165 | 15.15 | 290 | 725 | 3.86 / 228.83 | 2 | 4 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 31 | 15.11 | 438 | 205 | 0.21 / 221.28 | 2 | 3 |
2 | 7 | 2005.92 | 39 | 14.74 | 2966 | 1705 | 1.91 / 222.98 | 2 | 2 |
3 | 13 | 1412.40 | 18 | 14.84 | 2232 | 596 | 2.51 / 223.58 | 2 | 3 |
4 | 13 | 914.80 | 18 | 14.94 | 1585 | 426 | 2.93 / 224.00 | 2 | 3 |
5 | 13 | 394.28 | 18 | 15.09 | 884 | 240 | 3.17 / 224.24 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.16 | 289 | 723 | 3.90 / 224.97 | 2 | 6 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 31 | 15.12 | 444 | 208 | 0.21 / 217.32 | 2 | 3 |
2 | 7 | 2007.80 | 38 | 14.75 | 2966 | 1662 | 1.87 / 218.98 | 2 | 3 |
3 | 13 | 1426.00 | 18 | 14.84 | 2256 | 603 | 2.47 / 219.58 | 2 | 3 |
4 | 13 | 852.00 | 18 | 14.97 | 1505 | 406 | 2.88 / 219.99 | 2 | 3 |
5 | 13 | 395.40 | 18 | 15.11 | 877 | 239 | 3.12 / 220.23 | 2 | 3 |
6 | 13 | 74.20 | 18 | 15.18 | 406 | 111 | 3.23 / 220.34 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.16 | 294 | 735 | 3.96 / 221.07 | 2 | 9 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 31 | 15.10 | 432 | 202 | 0.20 / 213.40 | 2 | 3 |
2 | 7 | 2003.12 | 38 | 14.75 | 2960 | 1659 | 1.86 / 215.06 | 2 | 3 |
3 | 13 | 1379.04 | 18 | 14.85 | 2194 | 586 | 2.45 / 215.64 | 2 | 3 |
4 | 13 | 888.28 | 18 | 14.96 | 1559 | 420 | 2.87 / 216.06 | 2 | 3 |
5 | 13 | 342.56 | 18 | 15.12 | 807 | 220 | 3.09 / 216.28 | 2 | 3 |
6 | 13 | 44.20 | 18 | 15.19 | 359 | 98 | 3.19 / 216.38 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.16 | 291 | 728 | 3.91 / 217.11 | 2 | 6 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 31 | 15.12 | 425 | 199 | 0.20 / 209.43 | 2 | 3 |
2 | 7 | 2010.44 | 38 | 14.75 | 2974 | 1667 | 1.87 / 211.09 | 2 | 2 |
3 | 13 | 1399.32 | 18 | 14.85 | 2217 | 593 | 2.46 / 211.68 | 2 | 3 |
4 | 13 | 828.56 | 18 | 14.99 | 1478 | 399 | 2.86 / 212.08 | 2 | 3 |
5 | 13 | 475.04 | 18 | 15.07 | 1001 | 272 | 3.13 / 212.36 | 2 | 3 |
6 | 13 | 48.44 | 18 | 15.18 | 374 | 102 | 3.23 / 212.46 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.15 | 295 | 737 | 3.97 / 213.19 | 2 | 3 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 31 | 15.12 | 443 | 208 | 0.21 / 205.45 | 2 | 3 |
2 | 7 | 2004.36 | 38 | 14.76 | 2964 | 1662 | 1.87 / 207.12 | 2 | 3 |
3 | 13 | 1450.72 | 18 | 14.86 | 2283 | 611 | 2.48 / 207.73 | 2 | 3 |
4 | 13 | 832.24 | 18 | 14.99 | 1481 | 400 | 2.88 / 208.13 | 2 | 3 |
5 | 13 | 431.60 | 18 | 15.09 | 941 | 256 | 3.14 / 208.38 | 2 | 3 |
6 | 13 | 76.48 | 18 | 15.19 | 412 | 113 | 3.25 / 208.50 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.17 | 292 | 731 | 3.98 / 209.23 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 31 | 15.14 | 462 | 217 | 0.22 / 201.45 | 3 | 3 |
2 | 7 | 2003.28 | 38 | 14.77 | 2968 | 1666 | 1.88 / 203.11 | 2 | 2 |
3 | 13 | 1454.40 | 18 | 14.85 | 2289 | 612 | 2.49 / 203.73 | 2 | 3 |
4 | 13 | 943.36 | 18 | 14.95 | 1630 | 439 | 2.93 / 204.16 | 2 | 3 |
5 | 13 | 397.56 | 18 | 15.12 | 897 | 244 | 3.18 / 204.41 | 2 | 3 |
6 | 13 | 61.80 | 18 | 15.20 | 392 | 107 | 3.28 / 204.52 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.18 | 292 | 731 | 4.02 / 205.25 | 2 | 4 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 31 | 15.14 | 433 | 203 | 0.20 / 197.52 | 3 | 3 |
2 | 7 | 2015.72 | 38 | 14.75 | 2977 | 1669 | 1.87 / 199.19 | 2 | 2 |
3 | 13 | 1378.40 | 18 | 14.86 | 2198 | 588 | 2.46 / 199.78 | 2 | 3 |
4 | 13 | 837.92 | 18 | 15.00 | 1491 | 403 | 2.86 / 200.18 | 2 | 3 |
5 | 13 | 353.16 | 18 | 15.13 | 824 | 224 | 3.09 / 200.41 | 2 | 3 |
6 | 13 | 35.92 | 18 | 15.21 | 351 | 96 | 3.18 / 200.50 | 2 | 3 |
7 | 8 | 0.32 | 165 | 15.18 | 290 | 726 | 3.91 / 201.23 | 2 | 8 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 31 | 15.15 | 437 | 205 | 0.21 / 193.56 | 3 | 3 |
2 | 7 | 2011.48 | 38 | 14.77 | 2973 | 1669 | 1.87 / 195.23 | 2 | 2 |
3 | 13 | 1441.20 | 18 | 14.86 | 2278 | 609 | 2.48 / 195.84 | 2 | 3 |
4 | 13 | 885.64 | 18 | 14.98 | 1549 | 418 | 2.90 / 196.26 | 2 | 3 |
5 | 13 | 347.84 | 18 | 15.15 | 821 | 224 | 3.12 / 196.48 | 2 | 3 |
6 | 13 | 53.44 | 18 | 15.22 | 378 | 104 | 3.23 / 196.59 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.18 | 293 | 734 | 3.96 / 197.32 | 2 | 7 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.48 | 31 | 15.13 | 464 | 218 | 0.22 / 189.63 | 2 | 3 |
2 | 7 | 2003.60 | 38 | 14.77 | 2956 | 1659 | 1.88 / 191.29 | 2 | 2 |
3 | 13 | 1394.96 | 18 | 14.88 | 2212 | 592 | 2.47 / 191.88 | 2 | 3 |
4 | 13 | 843.24 | 18 | 15.00 | 1499 | 405 | 2.87 / 192.29 | 2 | 3 |
5 | 13 | 365.00 | 18 | 15.14 | 845 | 230 | 3.10 / 192.52 | 2 | 3 |
6 | 13 | 53.64 | 18 | 15.21 | 383 | 105 | 3.21 / 192.62 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.18 | 295 | 739 | 3.95 / 193.36 | 2 | 3 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 31 | 15.14 | 441 | 207 | 0.21 / 185.65 | 3 | 3 |
2 | 7 | 2012.52 | 38 | 14.77 | 2966 | 1665 | 1.87 / 187.31 | 2 | 2 |
3 | 13 | 1431.16 | 18 | 14.88 | 2263 | 606 | 2.48 / 187.92 | 2 | 3 |
4 | 13 | 902.24 | 18 | 14.99 | 1568 | 423 | 2.90 / 188.34 | 2 | 3 |
5 | 13 | 364.44 | 18 | 15.14 | 844 | 230 | 3.13 / 188.57 | 2 | 3 |
6 | 13 | 56.88 | 18 | 15.21 | 386 | 106 | 3.24 / 188.67 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.18 | 294 | 736 | 3.97 / 189.41 | 2 | 8 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 31 | 15.14 | 443 | 208 | 0.21 / 181.71 | 2 | 3 |
2 | 7 | 2012.44 | 38 | 14.76 | 2978 | 1670 | 1.88 / 183.38 | 2 | 2 |
3 | 13 | 1432.84 | 18 | 14.87 | 2253 | 603 | 2.48 / 183.98 | 2 | 3 |
4 | 13 | 808.32 | 18 | 15.01 | 1449 | 391 | 2.87 / 184.38 | 2 | 3 |
5 | 13 | 368.76 | 18 | 15.14 | 851 | 232 | 3.10 / 184.61 | 2 | 3 |
6 | 13 | 39.60 | 18 | 15.21 | 355 | 97 | 3.20 / 184.70 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.18 | 293 | 734 | 3.94 / 185.44 | 2 | 7 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 31 | 15.14 | 427 | 200 | 0.20 / 177.76 | 3 | 3 |
2 | 7 | 2004.40 | 38 | 14.78 | 2968 | 1667 | 1.87 / 179.43 | 2 | 2 |
3 | 13 | 1364.52 | 18 | 14.89 | 2183 | 585 | 2.45 / 180.01 | 2 | 3 |
4 | 13 | 874.24 | 18 | 15.00 | 1543 | 417 | 2.87 / 180.43 | 2 | 3 |
5 | 13 | 377.52 | 18 | 15.14 | 867 | 236 | 3.11 / 180.66 | 2 | 3 |
6 | 13 | 43.12 | 18 | 15.23 | 363 | 100 | 3.20 / 180.76 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.19 | 295 | 739 | 3.94 / 181.50 | 2 | 9 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 31 | 15.14 | 433 | 203 | 0.20 / 173.85 | 3 | 3 |
2 | 7 | 2008.52 | 38 | 14.77 | 2970 | 1667 | 1.87 / 175.51 | 2 | 3 |
3 | 13 | 1375.76 | 18 | 14.89 | 2194 | 588 | 2.46 / 176.10 | 2 | 3 |
4 | 13 | 819.20 | 18 | 15.01 | 1469 | 397 | 2.86 / 176.50 | 2 | 3 |
5 | 13 | 341.88 | 18 | 15.14 | 813 | 222 | 3.08 / 176.72 | 2 | 3 |
6 | 13 | 49.04 | 18 | 15.22 | 367 | 101 | 3.18 / 176.82 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.19 | 294 | 737 | 3.91 / 177.56 | 2 | 8 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.48 | 31 | 15.15 | 466 | 219 | 0.22 / 170.00 | 3 | 3 |
2 | 7 | 2008.48 | 38 | 14.77 | 2968 | 1666 | 1.88 / 171.67 | 2 | 3 |
3 | 13 | 1281.80 | 18 | 14.91 | 2059 | 553 | 2.44 / 172.22 | 2 | 3 |
4 | 13 | 771.76 | 18 | 15.04 | 1404 | 380 | 2.82 / 172.60 | 2 | 3 |
5 | 13 | 348.72 | 18 | 15.15 | 823 | 224 | 3.04 / 172.82 | 2 | 3 |
6 | 13 | 24.84 | 18 | 15.23 | 331 | 91 | 3.13 / 172.92 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.19 | 291 | 729 | 3.86 / 173.64 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 31 | 15.16 | 437 | 205 | 0.21 / 166.08 | 3 | 3 |
2 | 7 | 2011.28 | 38 | 14.77 | 2980 | 1673 | 1.88 / 167.75 | 2 | 3 |
3 | 13 | 1331.12 | 18 | 14.90 | 2127 | 570 | 2.45 / 168.32 | 2 | 3 |
4 | 13 | 797.80 | 18 | 15.02 | 1435 | 388 | 2.84 / 168.71 | 2 | 3 |
5 | 13 | 404.60 | 18 | 15.14 | 909 | 248 | 3.08 / 168.96 | 2 | 3 |
6 | 13 | 28.36 | 18 | 15.23 | 337 | 92 | 3.18 / 169.05 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.19 | 292 | 732 | 3.91 / 169.78 | 2 | 9 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 31 | 15.16 | 442 | 208 | 0.21 / 162.14 | 2 | 3 |
2 | 7 | 2011.64 | 38 | 14.76 | 2975 | 1669 | 1.88 / 163.81 | 2 | 3 |
3 | 13 | 1388.88 | 18 | 14.88 | 2207 | 591 | 2.47 / 164.40 | 2 | 3 |
4 | 13 | 898.48 | 18 | 15.00 | 1573 | 425 | 2.89 / 164.82 | 2 | 3 |
5 | 13 | 359.92 | 18 | 15.15 | 834 | 227 | 3.12 / 165.05 | 2 | 3 |
6 | 13 | 37.08 | 18 | 15.22 | 349 | 96 | 3.22 / 165.15 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.19 | 290 | 727 | 3.94 / 165.87 | 2 | 4 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 31 | 15.16 | 428 | 201 | 0.20 / 158.21 | 2 | 3 |
2 | 7 | 2010.08 | 38 | 14.77 | 2961 | 1662 | 1.86 / 159.87 | 2 | 3 |
3 | 13 | 1367.44 | 18 | 14.89 | 2178 | 584 | 2.45 / 160.45 | 2 | 3 |
4 | 13 | 888.40 | 18 | 14.99 | 1556 | 420 | 2.87 / 160.87 | 2 | 3 |
5 | 13 | 362.80 | 18 | 15.15 | 841 | 229 | 3.10 / 161.10 | 2 | 3 |
6 | 13 | 28.80 | 18 | 15.23 | 340 | 93 | 3.19 / 161.19 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.20 | 294 | 737 | 3.93 / 161.93 | 2 | 5 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 31 | 15.16 | 439 | 206 | 0.21 / 154.28 | 2 | 3 |
2 | 7 | 2004.04 | 38 | 14.78 | 2966 | 1666 | 1.87 / 155.95 | 2 | 3 |
3 | 13 | 1356.64 | 18 | 14.91 | 2163 | 581 | 2.45 / 156.53 | 2 | 2 |
4 | 13 | 861.20 | 18 | 15.02 | 1521 | 411 | 2.86 / 156.94 | 2 | 3 |
5 | 13 | 400.44 | 18 | 15.15 | 898 | 245 | 3.11 / 157.19 | 2 | 3 |
6 | 13 | 18.48 | 18 | 15.25 | 324 | 89 | 3.20 / 157.28 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.21 | 291 | 730 | 3.93 / 158.01 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 31 | 15.17 | 452 | 213 | 0.21 / 150.32 | 3 | 3 |
2 | 7 | 2007.32 | 39 | 14.78 | 2971 | 1713 | 1.93 / 152.04 | 2 | 2 |
3 | 13 | 1313.56 | 18 | 14.91 | 2104 | 565 | 2.49 / 152.60 | 2 | 3 |
4 | 13 | 874.36 | 18 | 15.01 | 1543 | 417 | 2.91 / 153.02 | 2 | 3 |
5 | 13 | 366.68 | 18 | 15.16 | 849 | 232 | 3.14 / 153.25 | 2 | 3 |
6 | 13 | 28.60 | 18 | 15.24 | 341 | 94 | 3.23 / 153.34 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.20 | 293 | 735 | 3.97 / 154.08 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 31 | 15.17 | 425 | 200 | 0.20 / 146.33 | 2 | 3 |
2 | 7 | 2004.12 | 38 | 14.79 | 2962 | 1665 | 1.86 / 147.99 | 2 | 2 |
3 | 13 | 1450.48 | 18 | 14.89 | 2290 | 614 | 2.48 / 148.60 | 2 | 3 |
4 | 13 | 900.96 | 18 | 15.01 | 1576 | 426 | 2.90 / 149.03 | 2 | 3 |
5 | 13 | 429.68 | 18 | 15.14 | 940 | 256 | 3.16 / 149.29 | 2 | 3 |
6 | 13 | 33.16 | 18 | 15.24 | 348 | 95 | 3.26 / 149.38 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.20 | 291 | 730 | 3.99 / 150.11 | 2 | 4 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 31 | 15.18 | 434 | 204 | 0.20 / 142.36 | 3 | 3 |
2 | 7 | 2012.00 | 38 | 14.77 | 2964 | 1664 | 1.87 / 144.03 | 2 | 2 |
3 | 13 | 1404.80 | 18 | 14.88 | 2223 | 595 | 2.46 / 144.62 | 2 | 3 |
4 | 13 | 955.72 | 18 | 15.00 | 1645 | 444 | 2.91 / 145.07 | 2 | 3 |
5 | 13 | 353.00 | 18 | 15.16 | 829 | 226 | 3.13 / 145.29 | 2 | 3 |
6 | 13 | 28.24 | 18 | 15.24 | 336 | 92 | 3.23 / 145.38 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.21 | 295 | 740 | 3.97 / 146.13 | 2 | 3 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.24 | 31 | 15.18 | 463 | 218 | 0.22 / 138.44 | 2 | 3 |
2 | 7 | 2005.32 | 38 | 14.78 | 2957 | 1661 | 1.88 / 140.10 | 2 | 2 |
3 | 13 | 1370.40 | 18 | 14.91 | 2175 | 584 | 2.46 / 140.69 | 2 | 3 |
4 | 13 | 872.04 | 18 | 15.02 | 1536 | 415 | 2.88 / 141.10 | 2 | 3 |
5 | 13 | 372.92 | 18 | 15.17 | 853 | 233 | 3.11 / 141.34 | 2 | 3 |
6 | 13 | 15.36 | 18 | 15.25 | 321 | 88 | 3.20 / 141.42 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.22 | 293 | 736 | 3.93 / 142.16 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 31 | 15.19 | 438 | 206 | 0.21 / 134.47 | 3 | 3 |
2 | 7 | 2003.00 | 38 | 14.78 | 2950 | 1657 | 1.86 / 136.13 | 2 | 2 |
3 | 13 | 1407.04 | 18 | 14.89 | 2225 | 596 | 2.46 / 136.72 | 2 | 3 |
4 | 13 | 901.92 | 18 | 15.01 | 1574 | 425 | 2.88 / 137.15 | 2 | 3 |
5 | 13 | 392.12 | 18 | 15.16 | 883 | 241 | 3.13 / 137.39 | 2 | 3 |
6 | 13 | 18.52 | 18 | 15.26 | 323 | 89 | 3.21 / 137.48 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.21 | 297 | 745 | 3.96 / 138.22 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 31 | 15.20 | 438 | 206 | 0.21 / 130.46 | 2 | 3 |
2 | 7 | 2003.80 | 38 | 14.79 | 2968 | 1668 | 1.87 / 132.13 | 2 | 2 |
3 | 13 | 1484.44 | 18 | 14.88 | 2325 | 623 | 2.50 / 132.75 | 2 | 2 |
4 | 13 | 942.56 | 18 | 15.01 | 1622 | 438 | 2.94 / 133.19 | 2 | 3 |
5 | 13 | 406.68 | 18 | 15.17 | 903 | 247 | 3.18 / 133.43 | 2 | 3 |
6 | 13 | 21.20 | 18 | 15.27 | 328 | 90 | 3.27 / 133.52 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.23 | 295 | 741 | 4.01 / 134.26 | 2 | 5 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 31 | 15.20 | 459 | 216 | 0.22 / 126.61 | 2 | 3 |
2 | 7 | 2012.48 | 39 | 14.79 | 2972 | 1714 | 1.93 / 128.33 | 2 | 3 |
3 | 13 | 1338.00 | 18 | 14.93 | 2141 | 575 | 2.51 / 128.90 | 2 | 3 |
4 | 13 | 807.28 | 18 | 15.04 | 1450 | 393 | 2.90 / 129.29 | 2 | 3 |
5 | 13 | 329.52 | 18 | 15.19 | 795 | 217 | 3.12 / 129.51 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.24 | 294 | 739 | 3.86 / 130.25 | 2 | 4 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 31 | 15.18 | 441 | 208 | 0.21 / 122.71 | 2 | 3 |
2 | 7 | 2009.00 | 39 | 14.80 | 2972 | 1715 | 1.92 / 124.42 | 2 | 2 |
3 | 13 | 1458.36 | 18 | 14.91 | 2300 | 617 | 2.54 / 125.04 | 2 | 3 |
4 | 13 | 793.08 | 18 | 15.06 | 1425 | 386 | 2.93 / 125.42 | 2 | 3 |
5 | 13 | 368.08 | 18 | 15.18 | 850 | 232 | 3.16 / 125.66 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.24 | 294 | 739 | 3.90 / 126.40 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 31 | 15.20 | 463 | 218 | 0.22 / 118.87 | 2 | 3 |
2 | 7 | 2003.60 | 38 | 14.80 | 2957 | 1663 | 1.88 / 120.53 | 2 | 3 |
3 | 13 | 1365.36 | 18 | 14.93 | 2169 | 583 | 2.46 / 121.12 | 2 | 3 |
4 | 13 | 889.72 | 18 | 15.04 | 1558 | 422 | 2.89 / 121.54 | 2 | 3 |
5 | 13 | 346.92 | 18 | 15.19 | 817 | 223 | 3.11 / 121.76 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.25 | 293 | 737 | 3.85 / 122.50 | 2 | 4 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 31 | 15.21 | 457 | 215 | 0.22 / 114.97 | 2 | 3 |
2 | 7 | 2016.76 | 38 | 14.80 | 2974 | 1673 | 1.89 / 116.64 | 2 | 3 |
3 | 13 | 1442.76 | 18 | 14.91 | 2271 | 609 | 2.50 / 117.25 | 2 | 3 |
4 | 13 | 901.72 | 18 | 15.04 | 1573 | 426 | 2.92 / 117.68 | 2 | 3 |
5 | 13 | 361.56 | 18 | 15.19 | 838 | 229 | 3.15 / 117.91 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.24 | 296 | 744 | 3.90 / 118.65 | 2 | 6 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 31 | 15.23 | 445 | 210 | 0.21 / 111.08 | 2 | 3 |
2 | 7 | 2009.96 | 38 | 14.79 | 2967 | 1668 | 1.88 / 112.75 | 2 | 3 |
3 | 13 | 1405.48 | 18 | 14.92 | 2232 | 599 | 2.48 / 113.35 | 2 | 3 |
4 | 13 | 914.96 | 18 | 15.03 | 1591 | 430 | 2.91 / 113.78 | 2 | 3 |
5 | 13 | 373.52 | 18 | 15.18 | 858 | 234 | 3.14 / 114.02 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.25 | 294 | 740 | 3.88 / 114.75 | 2 | 6 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 31 | 15.21 | 433 | 204 | 0.20 / 107.64 | 2 | 3 |
2 | 7 | 1555.00 | 38 | 14.97 | 2399 | 1365 | 1.57 / 109.01 | 2 | 2 |
3 | 13 | 1244.84 | 18 | 15.01 | 2020 | 546 | 2.11 / 109.55 | 2 | 3 |
4 | 13 | 761.32 | 18 | 15.12 | 1388 | 378 | 2.49 / 109.93 | 2 | 3 |
5 | 13 | 304.60 | 18 | 15.24 | 748 | 205 | 2.70 / 110.14 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.27 | 293 | 738 | 3.44 / 110.87 | 2 | 3 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.36 | 31 | 15.21 | 468 | 221 | 0.22 / 103.77 | 2 | 3 |
2 | 7 | 2013.44 | 39 | 14.81 | 2966 | 1713 | 1.93 / 105.49 | 2 | 2 |
3 | 13 | 1369.44 | 18 | 14.93 | 2183 | 587 | 2.52 / 106.07 | 2 | 3 |
4 | 13 | 809.20 | 18 | 15.06 | 1451 | 393 | 2.91 / 106.47 | 2 | 3 |
5 | 13 | 371.32 | 18 | 15.19 | 854 | 234 | 3.15 / 106.70 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.25 | 293 | 737 | 3.88 / 107.44 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.96 | 31 | 15.22 | 469 | 221 | 0.22 / 99.85 | 2 | 3 |
2 | 7 | 2005.88 | 38 | 14.81 | 2958 | 1665 | 1.89 / 101.51 | 2 | 3 |
3 | 13 | 1314.36 | 18 | 14.95 | 2111 | 568 | 2.45 / 102.08 | 2 | 3 |
4 | 13 | 833.12 | 18 | 15.07 | 1481 | 402 | 2.86 / 102.48 | 2 | 3 |
5 | 13 | 383.60 | 18 | 15.19 | 866 | 237 | 3.09 / 102.72 | 2 | 3 |
6 | 13 | 35.44 | 18 | 15.28 | 342 | 94 | 3.19 / 102.82 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.25 | 293 | 737 | 3.92 / 103.55 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.48 | 31 | 15.22 | 466 | 220 | 0.22 / 95.95 | 2 | 3 |
2 | 7 | 2003.80 | 38 | 14.83 | 2954 | 1665 | 1.88 / 97.61 | 2 | 3 |
3 | 13 | 1391.32 | 18 | 14.94 | 2209 | 594 | 2.48 / 98.21 | 2 | 3 |
4 | 13 | 920.00 | 18 | 15.05 | 1592 | 431 | 2.91 / 98.64 | 2 | 3 |
5 | 13 | 424.96 | 18 | 15.18 | 929 | 254 | 3.16 / 98.89 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.27 | 292 | 736 | 3.90 / 99.63 | 2 | 4 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 31 | 15.22 | 438 | 207 | 0.21 / 91.98 | 2 | 3 |
2 | 7 | 2010.40 | 38 | 14.83 | 2974 | 1676 | 1.88 / 93.65 | 2 | 2 |
3 | 13 | 1545.00 | 18 | 14.92 | 2406 | 646 | 2.53 / 94.30 | 2 | 3 |
4 | 13 | 967.44 | 18 | 15.05 | 1660 | 450 | 2.98 / 94.75 | 2 | 3 |
5 | 13 | 407.52 | 18 | 15.21 | 910 | 249 | 3.23 / 95.00 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.27 | 290 | 731 | 3.96 / 95.73 | 2 | 3 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 31 | 15.24 | 456 | 215 | 0.22 / 88.14 | 3 | 3 |
2 | 7 | 2008.36 | 38 | 14.83 | 2960 | 1668 | 1.88 / 89.81 | 2 | 2 |
3 | 13 | 1440.72 | 18 | 14.96 | 2273 | 612 | 2.50 / 90.42 | 2 | 3 |
4 | 13 | 805.64 | 18 | 15.10 | 1448 | 394 | 2.89 / 90.81 | 2 | 3 |
5 | 13 | 334.28 | 18 | 15.23 | 801 | 220 | 3.11 / 91.03 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.28 | 293 | 739 | 3.85 / 91.77 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 31 | 15.22 | 449 | 212 | 0.21 / 84.34 | 3 | 3 |
2 | 7 | 2003.04 | 38 | 14.83 | 2958 | 1667 | 1.88 / 86.01 | 2 | 3 |
3 | 13 | 1232.96 | 18 | 15.01 | 2006 | 542 | 2.42 / 86.55 | 2 | 3 |
4 | 13 | 851.04 | 18 | 15.10 | 1511 | 411 | 2.83 / 86.96 | 2 | 3 |
5 | 13 | 359.60 | 18 | 15.23 | 835 | 229 | 3.06 / 87.19 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.28 | 292 | 736 | 3.80 / 87.92 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 31 | 15.23 | 441 | 208 | 0.21 / 80.49 | 3 | 3 |
2 | 7 | 2010.92 | 38 | 14.83 | 2968 | 1673 | 1.88 / 82.16 | 2 | 2 |
3 | 13 | 1374.68 | 18 | 14.97 | 2182 | 588 | 2.47 / 82.75 | 2 | 3 |
4 | 13 | 785.80 | 18 | 15.11 | 1408 | 383 | 2.85 / 83.13 | 2 | 3 |
5 | 13 | 397.48 | 18 | 15.22 | 892 | 244 | 3.10 / 83.38 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.27 | 298 | 751 | 3.85 / 84.13 | 2 | 3 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 31 | 15.23 | 458 | 216 | 0.22 / 76.67 | 3 | 3 |
2 | 7 | 2006.72 | 38 | 14.84 | 2958 | 1668 | 1.88 / 78.34 | 2 | 3 |
3 | 13 | 1481.68 | 18 | 14.95 | 2325 | 626 | 2.51 / 78.96 | 2 | 3 |
4 | 13 | 773.16 | 18 | 15.11 | 1398 | 380 | 2.89 / 79.34 | 2 | 3 |
5 | 13 | 296.24 | 18 | 15.25 | 737 | 202 | 3.09 / 79.54 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.27 | 292 | 736 | 3.83 / 80.28 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 31 | 15.25 | 430 | 203 | 0.20 / 72.73 | 3 | 3 |
2 | 7 | 2003.48 | 38 | 14.85 | 2963 | 1672 | 1.88 / 74.40 | 2 | 3 |
3 | 13 | 1390.44 | 18 | 14.98 | 2215 | 597 | 2.47 / 75.00 | 2 | 3 |
4 | 13 | 786.80 | 18 | 15.12 | 1425 | 388 | 2.86 / 75.39 | 2 | 3 |
5 | 13 | 349.72 | 18 | 15.25 | 823 | 226 | 3.09 / 75.61 | 2 | 3 |
6 | 13 | 41.60 | 18 | 15.31 | 362 | 100 | 3.19 / 75.71 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.28 | 294 | 741 | 3.93 / 76.45 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 31 | 15.25 | 446 | 211 | 0.21 / 68.73 | 3 | 3 |
2 | 7 | 2011.88 | 38 | 14.85 | 2975 | 1679 | 1.89 / 70.41 | 2 | 2 |
3 | 13 | 1478.68 | 18 | 14.95 | 2324 | 625 | 2.52 / 71.04 | 2 | 3 |
4 | 13 | 879.08 | 18 | 15.09 | 1540 | 418 | 2.93 / 71.46 | 2 | 3 |
5 | 13 | 376.28 | 18 | 15.23 | 860 | 236 | 3.17 / 71.69 | 2 | 3 |
6 | 13 | 36.60 | 18 | 15.30 | 348 | 96 | 3.26 / 71.79 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.28 | 292 | 736 | 4.00 / 72.52 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 30 | 15.25 | 441 | 202 | 0.20 / 64.71 | 3 | 3 |
2 | 7 | 2005.44 | 39 | 14.85 | 2971 | 1721 | 1.92 / 66.43 | 2 | 3 |
3 | 13 | 1361.68 | 18 | 14.98 | 2181 | 588 | 2.51 / 67.02 | 2 | 3 |
4 | 13 | 867.00 | 18 | 15.10 | 1530 | 416 | 2.93 / 67.44 | 2 | 3 |
5 | 13 | 403.36 | 18 | 15.22 | 904 | 248 | 3.17 / 67.69 | 2 | 3 |
6 | 13 | 44.44 | 18 | 15.31 | 361 | 99 | 3.27 / 67.79 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.28 | 293 | 739 | 4.01 / 68.52 | 2 | 4 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 30 | 15.25 | 432 | 198 | 0.20 / 60.71 | 3 | 3 |
2 | 7 | 2006.24 | 38 | 14.87 | 2972 | 1679 | 1.88 / 62.39 | 2 | 2 |
3 | 13 | 1430.60 | 18 | 14.98 | 2266 | 611 | 2.49 / 63.00 | 2 | 2 |
4 | 13 | 917.72 | 18 | 15.09 | 1593 | 433 | 2.92 / 63.44 | 2 | 3 |
5 | 13 | 359.76 | 18 | 15.25 | 839 | 230 | 3.15 / 63.67 | 2 | 3 |
6 | 13 | 62.28 | 18 | 15.32 | 389 | 107 | 3.26 / 63.77 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.29 | 292 | 737 | 3.99 / 64.51 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 30 | 15.24 | 431 | 197 | 0.20 / 56.72 | 3 | 3 |
2 | 7 | 2010.84 | 39 | 14.87 | 2983 | 1730 | 1.93 / 58.45 | 2 | 2 |
3 | 13 | 1340.00 | 18 | 15.00 | 2151 | 581 | 2.51 / 59.03 | 2 | 3 |
4 | 13 | 874.40 | 18 | 15.10 | 1544 | 420 | 2.93 / 59.45 | 2 | 3 |
5 | 13 | 328.64 | 18 | 15.25 | 795 | 218 | 3.15 / 59.67 | 2 | 3 |
6 | 13 | 42.24 | 18 | 15.31 | 366 | 101 | 3.25 / 59.77 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.28 | 295 | 744 | 3.99 / 60.52 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 30 | 15.25 | 449 | 205 | 0.21 / 52.85 | 3 | 3 |
2 | 7 | 1895.56 | 38 | 14.89 | 2834 | 1604 | 1.81 / 54.45 | 2 | 2 |
3 | 13 | 1434.52 | 18 | 14.98 | 2273 | 613 | 2.42 / 55.06 | 2 | 3 |
4 | 13 | 785.44 | 18 | 15.13 | 1426 | 388 | 2.81 / 55.45 | 2 | 3 |
5 | 13 | 334.72 | 18 | 15.26 | 806 | 221 | 3.03 / 55.67 | 2 | 3 |
6 | 13 | 40.04 | 18 | 15.33 | 364 | 100 | 3.13 / 55.77 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.29 | 298 | 752 | 3.88 / 56.53 | 2 | 4 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 30 | 15.26 | 436 | 200 | 0.20 / 48.91 | 3 | 3 |
2 | 7 | 2013.56 | 38 | 14.86 | 2974 | 1679 | 1.88 / 50.59 | 2 | 3 |
3 | 13 | 1400.72 | 18 | 14.99 | 2227 | 601 | 2.48 / 51.19 | 2 | 3 |
4 | 13 | 813.12 | 18 | 15.12 | 1464 | 398 | 2.88 / 51.59 | 2 | 3 |
5 | 13 | 318.72 | 18 | 15.25 | 779 | 214 | 3.09 / 51.80 | 2 | 3 |
6 | 13 | 31.88 | 18 | 15.32 | 349 | 96 | 3.19 / 51.90 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.29 | 296 | 747 | 3.94 / 52.64 | 2 | 4 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 30 | 15.25 | 457 | 209 | 0.21 / 44.84 | 3 | 3 |
2 | 7 | 2010.96 | 38 | 14.88 | 2980 | 1685 | 1.89 / 46.52 | 2 | 3 |
3 | 13 | 1464.68 | 18 | 15.00 | 2307 | 623 | 2.52 / 47.14 | 2 | 3 |
4 | 13 | 990.68 | 18 | 15.09 | 1702 | 462 | 2.98 / 47.61 | 2 | 3 |
5 | 13 | 396.96 | 18 | 15.25 | 900 | 247 | 3.23 / 47.85 | 2 | 3 |
6 | 13 | 41.96 | 18 | 15.33 | 361 | 100 | 3.33 / 47.95 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.29 | 299 | 754 | 4.08 / 48.71 | 2 | 4 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 30 | 15.26 | 447 | 205 | 0.20 / 40.91 | 2 | 3 |
2 | 7 | 2005.84 | 38 | 14.87 | 2968 | 1677 | 1.88 / 42.58 | 2 | 2 |
3 | 13 | 1402.20 | 18 | 14.99 | 2228 | 601 | 2.48 / 43.18 | 2 | 2 |
4 | 13 | 805.44 | 18 | 15.13 | 1449 | 395 | 2.88 / 43.58 | 2 | 3 |
5 | 13 | 302.00 | 18 | 15.27 | 753 | 207 | 3.08 / 43.79 | 2 | 3 |
6 | 13 | 30.84 | 18 | 15.33 | 343 | 95 | 3.18 / 43.88 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.30 | 296 | 747 | 3.93 / 44.63 | 2 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 30 | 15.26 | 433 | 198 | 0.20 / 36.92 | 3 | 3 |
2 | 7 | 2006.28 | 38 | 14.88 | 2968 | 1678 | 1.88 / 38.60 | 2 | 2 |
3 | 13 | 1434.64 | 18 | 15.00 | 2272 | 613 | 2.49 / 39.21 | 2 | 2 |
4 | 13 | 772.48 | 18 | 15.15 | 1407 | 384 | 2.87 / 39.59 | 2 | 2 |
5 | 13 | 380.08 | 18 | 15.26 | 869 | 239 | 3.11 / 39.83 | 2 | 3 |
6 | 13 | 76.40 | 18 | 15.33 | 418 | 115 | 3.23 / 39.95 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.29 | 299 | 754 | 3.98 / 40.70 | 2 | 4 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 30 | 15.26 | 435 | 199 | 0.20 / 33.00 | 2 | 3 |
2 | 7 | 2006.48 | 38 | 14.88 | 2967 | 1678 | 1.88 / 34.68 | 2 | 2 |
3 | 13 | 1305.40 | 18 | 15.03 | 2102 | 569 | 2.45 / 35.25 | 2 | 2 |
4 | 13 | 820.56 | 18 | 15.13 | 1470 | 400 | 2.85 / 35.65 | 2 | 3 |
5 | 13 | 375.16 | 18 | 15.25 | 860 | 236 | 3.08 / 35.88 | 2 | 3 |
6 | 13 | 24.84 | 18 | 15.33 | 333 | 92 | 3.17 / 35.97 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.30 | 295 | 745 | 3.92 / 36.72 | 2 | 4 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 30 | 15.27 | 460 | 211 | 0.21 / 29.09 | 3 | 3 |
2 | 3 | 1019.16 | 1 | 15.31 | 1761 | 27 | 0.24 / 29.12 | 2 | 2 |
3 | 7 | 2012.40 | 38 | 14.88 | 2973 | 1681 | 1.92 / 30.80 | 2 | 2 |
4 | 13 | 1279.52 | 18 | 15.03 | 2070 | 560 | 2.48 / 31.36 | 2 | 2 |
5 | 13 | 806.32 | 18 | 15.14 | 1447 | 394 | 2.87 / 31.75 | 2 | 2 |
6 | 13 | 336.28 | 18 | 15.27 | 794 | 218 | 3.09 / 31.97 | 2 | 2 |
7 | 13 | 13.76 | 18 | 15.34 | 314 | 87 | 3.18 / 32.06 | 2 | 2 |
8 | 8 | 0.20 | 165 | 15.30 | 294 | 742 | 3.92 / 32.80 | 2 | 4 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 29 | 15.27 | 455 | 201 | 0.20 / 25.17 | 3 | 3 |
2 | 7 | 2009.68 | 38 | 14.88 | 2963 | 1675 | 1.88 / 26.85 | 2 | 2 |
3 | 13 | 1306.96 | 18 | 15.03 | 2104 | 569 | 2.45 / 27.42 | 2 | 2 |
4 | 13 | 811.68 | 18 | 15.14 | 1446 | 394 | 2.84 / 27.81 | 2 | 2 |
5 | 13 | 377.52 | 18 | 15.26 | 857 | 235 | 3.08 / 28.05 | 2 | 2 |
6 | 13 | 23.56 | 18 | 15.33 | 327 | 90 | 3.17 / 28.14 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.30 | 294 | 742 | 3.91 / 28.88 | 2 | 4 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 29 | 15.27 | 432 | 191 | 0.19 / 20.62 | 2 | 3 |
2 | 3 | 1037.72 | 1 | 15.30 | 1814 | 28 | 0.22 / 20.65 | 2 | 2 |
3 | 7 | 2004.24 | 74 | 14.78 | 2946 | 3222 | 3.44 / 23.87 | 2 | 2 |
4 | 13 | 435.72 | 18 | 15.26 | 941 | 258 | 3.70 / 24.13 | 2 | 3 |
5 | 13 | 85.04 | 18 | 15.34 | 418 | 115 | 3.82 / 24.24 | 2 | 2 |
6 | 8 | 0.24 | 165 | 15.32 | 289 | 731 | 4.55 / 24.97 | 2 | 4 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 29 | 15.28 | 468 | 207 | 0.21 / 16.03 | 3 | 3 |
2 | 7 | 2007.96 | 74 | 14.78 | 2951 | 3228 | 3.43 / 19.25 | 2 | 2 |
3 | 13 | 524.20 | 18 | 15.22 | 1067 | 292 | 3.73 / 19.55 | 2 | 3 |
4 | 13 | 109.84 | 18 | 15.33 | 458 | 126 | 3.85 / 19.67 | 2 | 2 |
5 | 8 | 0.08 | 165 | 15.31 | 298 | 753 | 4.61 / 20.43 | 2 | 5 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 28 | 15.28 | 439 | 188 | 0.19 / 12.17 | 2 | 3 |
2 | 7 | 1528.00 | 74 | 14.97 | 2348 | 2601 | 2.79 / 14.77 | 2 | 2 |
3 | 13 | 323.48 | 18 | 15.31 | 783 | 216 | 3.00 / 14.98 | 2 | 2 |
4 | 13 | 19.80 | 18 | 15.36 | 326 | 90 | 3.09 / 15.07 | 2 | 2 |
5 | 8 | 0.08 | 165 | 15.32 | 295 | 746 | 3.84 / 15.82 | 2 | 5 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 27 | 15.27 | 461 | 190 | 0.19 / 8.28 | 3 | 3 |
2 | 10 | 1003.88 | 2 | 15.28 | 1741 | 53 | 0.24 / 8.33 | 2 | 2 |
3 | 7 | 1520.84 | 74 | 14.97 | 2343 | 2596 | 2.84 / 10.93 | 2 | 2 |
4 | 13 | 300.52 | 18 | 15.30 | 744 | 205 | 3.04 / 11.14 | 2 | 3 |
5 | 13 | 34.04 | 18 | 15.35 | 348 | 96 | 3.14 / 11.23 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.32 | 296 | 748 | 3.89 / 11.98 | 2 | 4 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 31 | 15.32 | 443 | 210 | 0.21 / 4.47 | 2 | 3 |
2 | 3 | 866.12 | -3 | 15.68 | 0 | 0 | 0.00 / 4.47 | 2 | 3 |
3 | 7 | 1517.48 | 74 | 14.99 | 2332 | 2587 | 2.80 / 7.06 | 2 | 2 |
4 | 13 | 283.24 | 18 | 15.32 | 718 | 198 | 3.00 / 7.25 | 2 | 2 |
5 | 13 | 29.72 | 18 | 15.36 | 338 | 93 | 3.09 / 7.35 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.32 | 294 | 743 | 3.83 / 8.09 | 2 | 4 |
Average= | 2.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 26 | 15.51 | 397 | 160 | 0.16 / 1.60 | 3 | 3 |
2 | 10 | 1008.92 | 2 | 15.38 | 1718 | 53 | 0.21 / 1.65 | 2 | 2 |
3 | 7 | 989.20 | 75 | 15.18 | 1641 | 1868 | 2.08 / 3.52 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.38 | 291 | 738 | 2.82 / 4.26 | 2 | 4 |
Average= | 2.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 79.04 | 26 | 15.66 | 352 | 143 | 0.14 / 0.14 | 3 | 3 |
2 | 7 | 95.32 | 74 | 15.63 | 377 | 436 | 0.58 / 0.58 | 3 | 3 |
3 | 8 | 0.36 | 240 | 15.59 | 230 | 861 | 1.44 / 1.44 | 3 | 5 |
Average= | 1.44 (KJ/cycle) |