SIO Argo Site:
Pump Diagnostics Page   



Serial= 3133 WMO= 5906782

Return

←PreviousNext→

Cycle 76 GMT 21/11/2024 14:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 15.06 417 188 0.19 / 289.86 2 4
2 7 2009.48 39 14.71 2867 1645 1.83 / 291.51 2 9
3 13 1459.16 18 14.80 2229 594 2.43 / 292.10 2 12
4 13 792.76 18 14.93 1420 382 2.81 / 292.48 2 13
5 13 306.76 18 15.07 748 203 3.01 / 292.68 2 13
6 13 59.36 18 15.12 378 103 3.11 / 292.79 2 5
7 8 -0.08 165 15.09 286 712 3.83 / 293.50 2 11
Average= 3.81
(KJ/cycle)

Cycle 75 GMT 11/11/2024 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 15.06 418 189 0.19 / 286.02 2 3
2 7 2011.84 38 14.72 2874 1608 1.80 / 287.63 2 9
3 13 1487.88 18 14.79 2259 601 2.40 / 288.23 2 8
4 13 916.64 18 14.90 1576 423 2.82 / 288.65 2 13
5 13 316.60 18 15.07 771 209 3.03 / 288.86 2 12
6 13 64.12 18 15.13 385 105 3.13 / 288.96 2 12
7 8 -0.08 165 15.10 284 708 3.84 / 289.67 2 28
Average= 3.81
(KJ/cycle)

Cycle 74 GMT 2/11/2024 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 30 15.06 420 190 0.19 / 282.24 2 4
2 7 2010.52 38 14.72 2875 1608 1.80 / 283.84 2 6
3 13 1382.76 18 14.82 2131 568 2.37 / 284.41 2 10
4 13 847.20 18 14.91 1484 398 2.76 / 284.81 2 14
5 13 304.64 18 15.07 746 202 2.97 / 285.01 2 13
6 13 63.96 18 15.12 382 104 3.07 / 285.12 2 9
7 8 0.08 165 15.10 286 713 3.78 / 285.83 2 27
Average= 3.81
(KJ/cycle)

Cycle 73 GMT 23/10/2024 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 30 15.08 410 185 0.19 / 278.38 2 4
2 7 2002.72 39 14.72 2857 1640 1.83 / 280.02 2 9
3 13 1289.76 18 14.84 2015 538 2.36 / 280.55 2 9
4 13 939.16 18 14.89 1593 427 2.79 / 280.98 2 13
5 13 349.12 18 15.06 822 223 3.01 / 281.20 2 13
6 13 94.76 18 15.11 442 120 3.13 / 281.32 2 11
7 8 0.04 165 15.09 290 722 3.86 / 282.05 2 18
Average= 3.81
(KJ/cycle)

Cycle 72 GMT 13/10/2024 9:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 30 15.06 436 197 0.20 / 274.57 2 3
2 7 2014.00 38 14.73 2878 1611 1.81 / 276.18 2 9
3 13 1457.96 18 14.81 2238 597 2.40 / 276.78 2 10
4 13 859.80 18 14.93 1497 402 2.81 / 277.18 2 13
5 13 307.08 18 15.10 754 205 3.01 / 277.39 2 14
6 13 70.12 18 15.14 388 106 3.12 / 277.49 2 7
7 8 0.12 165 15.12 280 699 3.82 / 278.19 2 16
Average= 3.81
(KJ/cycle)

Cycle 71 GMT 3/10/2024 14:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 30 15.07 436 197 0.20 / 270.75 2 3
2 7 2011.20 38 14.72 2863 1601 1.80 / 272.35 2 5
3 13 1383.56 18 14.82 2132 569 2.37 / 272.92 2 11
4 13 878.00 18 14.92 1514 407 2.77 / 273.33 2 13
5 13 316.16 18 15.08 761 207 2.98 / 273.54 2 14
6 13 68.64 18 15.13 397 108 3.09 / 273.64 2 7
7 8 -0.04 165 15.11 293 730 3.82 / 274.37 2 34
Average= 3.81
(KJ/cycle)

Cycle 70 GMT 23/ 9/2024 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 30 15.08 419 190 0.19 / 266.97 2 4
2 7 2003.60 38 14.74 2863 1604 1.79 / 268.58 2 10
3 13 1436.56 18 14.83 2197 586 2.38 / 269.16 2 10
4 13 761.04 18 14.96 1360 366 2.75 / 269.53 2 13
5 13 315.72 18 15.09 761 207 2.95 / 269.74 2 15
6 13 63.32 18 15.15 380 104 3.06 / 269.84 2 14
7 8 0.24 165 15.11 287 716 3.77 / 270.56 2 3
Average= 3.81
(KJ/cycle)

Cycle 69 GMT 14/ 9/2024 0:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 30 15.08 418 189 0.19 / 263.14 2 3
2 7 2006.24 39 14.74 2868 1649 1.84 / 264.79 2 8
3 13 1359.04 18 14.82 2113 564 2.40 / 265.35 2 11
4 13 861.16 18 14.94 1496 402 2.80 / 265.75 2 14
5 13 314.28 18 15.09 764 208 3.01 / 265.96 2 14
6 13 71.40 18 15.14 402 110 3.12 / 266.07 2 13
7 8 0.00 165 15.11 287 716 3.84 / 266.78 2 6
Average= 3.81
(KJ/cycle)

Cycle 68 GMT 4/ 9/2024 5:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 15.09 432 196 0.20 / 259.35 2 3
2 7 2004.16 38 14.75 2840 1592 1.79 / 260.94 2 5
3 13 1401.76 18 14.84 2167 579 2.37 / 261.52 2 8
4 13 819.72 18 14.95 1458 392 2.76 / 261.91 2 14
5 13 321.72 18 15.10 779 212 2.97 / 262.12 2 13
6 13 71.68 18 15.16 394 108 3.08 / 262.23 2 11
7 8 -0.04 165 15.13 288 719 3.80 / 262.95 2 9
Average= 3.81
(KJ/cycle)

Cycle 67 GMT 25/ 8/2024 10:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 30 15.10 458 207 0.21 / 255.57 2 4
2 7 2003.08 38 14.74 2850 1596 1.80 / 257.17 2 10
3 13 1369.60 18 14.85 2115 565 2.37 / 257.73 2 10
4 13 838.84 18 14.95 1461 393 2.76 / 258.13 2 13
5 13 296.56 18 15.12 728 198 2.96 / 258.32 2 13
6 13 88.72 18 15.16 421 115 3.08 / 258.44 2 16
7 8 -0.04 165 15.14 285 712 3.79 / 259.15 2 8
Average= 3.81
(KJ/cycle)

Cycle 66 GMT 15/ 8/2024 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 15.10 429 194 0.19 / 251.77 2 3
2 7 2010.56 38 14.74 2865 1605 1.80 / 253.38 2 5
3 13 1373.04 18 14.86 2124 568 2.37 / 253.94 2 12
4 13 835.44 18 14.97 1451 391 2.76 / 254.33 2 13
5 13 297.56 18 15.12 739 201 2.96 / 254.54 2 13
6 13 58.68 18 15.16 380 104 3.06 / 254.64 2 6
7 8 0.08 165 15.13 290 724 3.79 / 255.36 2 3
Average= 3.81
(KJ/cycle)

Cycle 65 GMT 5/ 8/2024 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.16 30 15.11 448 203 0.20 / 247.96 2 2
2 7 2015.72 39 14.75 2874 1653 1.86 / 249.61 2 9
3 13 1372.36 18 14.85 2118 566 2.42 / 250.18 2 10
4 13 797.68 18 14.98 1411 380 2.80 / 250.56 2 14
5 13 294.96 18 15.13 729 199 3.00 / 250.76 2 13
6 13 90.88 18 15.16 423 115 3.12 / 250.87 2 13
7 8 0.36 165 15.14 282 704 3.82 / 251.58 2 4
Average= 3.81
(KJ/cycle)

Cycle 64 GMT 27/ 7/2024 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 30 15.11 434 197 0.20 / 244.14 2 3
2 7 2012.16 38 14.74 2871 1608 1.80 / 245.74 2 9
3 13 1368.32 18 14.86 2114 565 2.37 / 246.31 2 9
4 13 863.92 18 14.96 1520 409 2.78 / 246.72 2 14
5 13 323.52 18 15.12 776 211 2.99 / 246.93 2 14
6 13 74.36 18 15.17 402 110 3.10 / 247.04 2 8
7 8 0.12 165 15.15 286 715 3.82 / 247.75 2 19
Average= 3.81
(KJ/cycle)

Cycle 63 GMT 17/ 7/2024 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 15.11 428 194 0.19 / 240.36 2 3
2 7 2006.12 38 14.75 2866 1606 1.80 / 241.97 2 8
3 13 1360.96 18 14.86 2109 564 2.36 / 242.53 2 8
4 13 781.04 18 14.99 1402 378 2.74 / 242.91 2 12
5 13 303.76 18 15.13 742 202 2.94 / 243.11 2 12
6 13 61.96 18 15.17 382 104 3.05 / 243.22 2 6
7 8 0.16 165 15.14 289 722 3.77 / 243.94 2 5
Average= 3.81
(KJ/cycle)

Cycle 62 GMT 7/ 7/2024 10:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 15.12 439 199 0.20 / 236.52 2 3
2 7 2005.12 38 14.76 2872 1611 1.81 / 238.13 2 7
3 13 1382.24 18 14.87 2134 571 2.38 / 238.70 2 9
4 13 810.08 18 14.99 1423 384 2.77 / 239.08 2 13
5 13 400.20 18 15.10 896 244 3.01 / 239.32 2 14
6 13 78.08 18 15.18 415 113 3.12 / 239.44 2 8
7 8 0.00 165 15.15 292 730 3.85 / 240.17 2 21
Average= 3.81
(KJ/cycle)

Cycle 61 GMT 27/ 6/2024 15: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 30 15.14 429 195 0.19 / 232.66 2 2
2 7 2004.84 39 14.76 2873 1654 1.85 / 234.32 2 6
3 13 1378.00 18 14.87 2153 576 2.42 / 234.89 2 12
4 13 846.24 18 14.99 1484 400 2.83 / 235.29 2 13
5 13 308.88 18 15.15 754 206 3.03 / 235.50 2 13
6 13 66.12 18 15.18 388 106 3.14 / 235.61 2 10
7 8 0.20 165 15.16 284 710 3.85 / 236.32 2 5
Average= 3.81
(KJ/cycle)

Cycle 60 GMT 17/ 6/2024 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 15.14 428 194 0.19 / 228.87 2 3
2 7 2010.88 38 14.78 2877 1616 1.81 / 230.49 2 6
3 13 1418.72 18 14.87 2194 587 2.40 / 231.07 2 10
4 13 762.36 18 15.02 1370 370 2.77 / 231.44 2 12
5 13 278.44 18 15.17 709 194 2.96 / 231.64 2 13
6 13 83.04 18 15.20 424 116 3.08 / 231.75 2 10
7 8 0.12 165 15.17 286 716 3.79 / 232.47 2 28
Average= 3.81
(KJ/cycle)

Cycle 59 GMT 8/ 6/2024 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 15.14 414 188 0.19 / 225.04 2 3
2 7 2004.76 38 14.77 2857 1604 1.79 / 226.64 2 9
3 13 1403.68 18 14.87 2165 579 2.37 / 227.22 2 11
4 13 881.68 18 14.98 1527 412 2.78 / 227.64 2 14
5 13 310.96 18 15.15 758 207 2.99 / 227.84 2 14
6 13 66.88 18 15.20 393 108 3.10 / 227.95 2 8
7 8 0.16 165 15.17 290 726 3.82 / 228.68 2 21
Average= 3.81
(KJ/cycle)

Cycle 58 GMT 29/ 5/2024 5: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 30 15.13 442 201 0.20 / 221.26 2 2
2 7 2004.72 38 14.79 2858 1606 1.81 / 222.86 2 6
3 13 1432.64 18 14.87 2208 591 2.40 / 223.45 2 12
4 13 788.92 18 15.04 1398 378 2.78 / 223.83 2 14
5 13 299.80 18 15.17 742 203 2.98 / 224.04 2 13
6 13 60.20 18 15.22 385 105 3.08 / 224.14 2 12
7 8 0.32 165 15.18 284 711 3.80 / 224.85 2 24
Average= 3.81
(KJ/cycle)

Cycle 57 GMT 19/ 5/2024 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 30 15.13 448 203 0.20 / 217.45 2 4
2 7 2004.32 38 14.79 2857 1606 1.81 / 219.05 2 8
3 13 1318.76 18 14.91 2070 556 2.36 / 219.61 2 10
4 13 873.56 18 15.00 1516 409 2.77 / 220.02 2 13
5 13 311.52 18 15.16 759 207 2.98 / 220.22 2 13
6 13 69.04 18 15.21 396 108 3.09 / 220.33 2 8
7 8 0.04 165 15.18 289 724 3.81 / 221.06 2 5
Average= 3.81
(KJ/cycle)

Cycle 56 GMT 9/ 5/2024 14:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 30 15.16 431 196 0.20 / 213.59 2 3
2 7 2005.36 38 14.77 2873 1612 1.81 / 215.20 2 7
3 13 1457.08 18 14.87 2242 600 2.41 / 215.80 2 11
4 13 819.36 18 15.02 1445 391 2.80 / 216.19 2 12
5 13 351.64 18 15.15 821 224 3.02 / 216.41 2 14
6 13 56.08 18 15.21 385 105 3.13 / 216.52 2 11
7 8 0.08 165 15.18 289 724 3.85 / 217.24 2 27
Average= 3.81
(KJ/cycle)

Cycle 55 GMT 29/ 4/2024 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 30 15.15 419 190 0.19 / 209.82 2 3
2 7 2005.08 38 14.79 2878 1617 1.81 / 211.43 2 6
3 13 1344.08 18 14.91 2092 561 2.37 / 212.00 2 11
4 13 827.08 18 15.03 1454 393 2.76 / 212.39 2 13
5 13 286.52 18 15.18 715 195 2.96 / 212.58 2 12
6 13 61.20 18 15.22 373 102 3.06 / 212.69 2 11
7 8 0.20 165 15.19 281 704 3.76 / 213.39 2 15
Average= 3.81
(KJ/cycle)

Cycle 54 GMT 19/ 4/2024 23:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 15.15 413 188 0.19 / 206.10 2 3
2 7 2006.44 38 14.77 2857 1604 1.79 / 207.70 2 9
3 13 1244.68 18 14.93 1967 529 2.32 / 208.23 2 12
4 13 780.88 18 15.04 1392 377 2.70 / 208.61 2 12
5 13 297.16 18 15.17 741 202 2.90 / 208.81 2 13
6 13 59.04 18 15.21 378 103 3.00 / 208.91 2 9
7 8 -0.12 165 15.18 285 714 3.72 / 209.63 2 14
Average= 3.81
(KJ/cycle)

Cycle 53 GMT 10/ 4/2024 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 30 15.16 438 199 0.20 / 202.26 2 3
2 7 2004.96 38 14.78 2875 1615 1.81 / 203.87 2 9
3 13 1512.24 18 14.88 2295 615 2.43 / 204.49 2 12
4 13 770.12 18 15.05 1379 374 2.80 / 204.86 2 12
5 13 329.20 18 15.17 787 215 3.02 / 205.08 2 14
6 13 71.48 18 15.22 403 110 3.13 / 205.19 2 15
7 8 0.00 165 15.19 288 722 3.85 / 205.91 2 10
Average= 3.81
(KJ/cycle)

Cycle 52 GMT 31/ 3/2024 9:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 30 15.16 411 187 0.19 / 198.43 2 3
2 7 2010.40 38 14.79 2888 1623 1.81 / 200.05 2 9
3 13 1418.76 18 14.90 2176 584 2.39 / 200.64 2 10
4 13 829.60 18 15.02 1459 394 2.79 / 201.03 2 12
5 13 325.00 18 15.17 780 213 3.00 / 201.25 2 13
6 13 49.00 18 15.23 361 99 3.10 / 201.34 2 8
7 8 0.24 165 15.19 286 717 3.82 / 202.06 2 24
Average= 3.81
(KJ/cycle)

Cycle 51 GMT 21/ 3/2024 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 30 15.15 438 199 0.20 / 194.64 2 4
2 7 2012.20 38 14.77 2879 1616 1.81 / 196.25 2 8
3 13 1364.36 18 14.92 2118 569 2.38 / 196.82 2 10
4 13 783.52 18 15.04 1388 376 2.76 / 197.20 2 12
5 13 371.00 18 15.15 842 230 2.99 / 197.43 2 13
6 13 57.80 18 15.21 373 102 3.09 / 197.53 2 7
7 8 0.24 165 15.19 286 717 3.81 / 198.24 2 22
Average= 3.81
(KJ/cycle)

Cycle 50 GMT 11/ 3/2024 18:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 15.17 437 199 0.20 / 190.78 2 3
2 7 2004.36 38 14.80 2867 1612 1.81 / 192.39 2 7
3 13 1367.12 18 14.91 2141 575 2.39 / 192.97 2 12
4 13 849.52 18 15.03 1478 400 2.79 / 193.37 2 12
5 13 379.32 18 15.15 865 236 3.02 / 193.60 2 14
6 13 70.48 18 15.22 400 110 3.13 / 193.71 2 10
7 8 -0.08 165 15.20 289 725 3.86 / 194.44 2 10
Average= 3.81
(KJ/cycle)

Cycle 49 GMT 1/ 3/2024 23:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 30 15.18 434 198 0.20 / 186.92 2 3
2 7 2005.56 38 14.79 2890 1624 1.82 / 188.54 2 8
3 13 1416.68 18 14.92 2181 586 2.41 / 189.13 2 9
4 13 831.48 18 15.05 1468 398 2.81 / 189.52 2 13
5 13 298.92 18 15.19 755 206 3.01 / 189.73 2 13
6 13 58.08 18 15.23 386 106 3.12 / 189.84 2 10
7 8 0.04 165 15.21 296 743 3.86 / 190.58 2 13
Average= 3.81
(KJ/cycle)

Cycle 48 GMT 21/ 2/2024 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 29 15.18 436 192 0.19 / 183.11 2 3
2 7 2003.48 38 14.80 2870 1614 1.81 / 184.73 2 9
3 13 1434.88 18 14.92 2198 590 2.40 / 185.32 2 10
4 13 800.28 18 15.06 1415 384 2.78 / 185.70 2 12
5 13 305.40 18 15.20 750 205 2.99 / 185.91 2 13
6 13 66.56 18 15.24 388 106 3.09 / 186.01 2 10
7 8 0.28 165 15.21 282 708 3.80 / 186.72 2 27
Average= 3.81
(KJ/cycle)

Cycle 47 GMT 11/ 2/2024 9:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 30 15.18 422 192 0.19 / 179.31 2 3
2 7 2004.28 38 14.83 2881 1624 1.82 / 180.94 2 8
3 13 1325.36 18 14.96 2083 561 2.38 / 181.50 2 12
4 13 836.56 18 15.06 1473 399 2.78 / 181.90 2 13
5 13 287.48 18 15.22 719 197 2.97 / 182.09 2 13
6 13 43.92 18 15.26 363 100 3.07 / 182.19 2 11
7 8 0.16 165 15.22 290 728 3.80 / 182.92 2 23
Average= 3.81
(KJ/cycle)

Cycle 46 GMT 1/ 2/2024 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 29 15.20 448 197 0.20 / 175.48 2 3
2 7 2013.24 38 14.81 2892 1628 1.83 / 177.11 2 9
3 13 1346.00 18 14.94 2106 566 2.39 / 177.68 2 11
4 13 735.96 18 15.09 1353 368 2.76 / 178.04 2 13
5 13 391.72 18 15.18 887 242 3.00 / 178.28 2 15
6 13 47.60 18 15.27 368 101 3.10 / 178.39 2 8
7 8 -0.04 165 15.22 292 733 3.84 / 179.12 2 13
Average= 3.81
(KJ/cycle)

Cycle 45 GMT 22/ 1/2024 18:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 29 15.19 431 190 0.19 / 171.70 2 3
2 7 2010.60 38 14.81 2888 1625 1.82 / 173.32 2 8
3 13 1244.56 18 14.95 1997 537 2.35 / 173.86 2 11
4 13 802.04 18 15.06 1420 385 2.74 / 174.25 2 12
5 13 295.28 18 15.20 744 204 2.94 / 174.45 2 14
6 13 55.00 18 15.25 379 104 3.05 / 174.55 2 15
7 8 0.36 165 15.22 291 731 3.78 / 175.28 2 6
Average= 3.81
(KJ/cycle)

Cycle 44 GMT 12/ 1/2024 23:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 15.19 440 194 0.19 / 167.80 2 3
2 7 2007.00 38 14.84 2883 1626 1.82 / 169.42 2 6
3 13 1437.08 18 14.94 2208 594 2.41 / 170.02 2 10
4 13 838.60 18 15.07 1478 401 2.81 / 170.42 2 13
5 13 375.68 18 15.20 877 240 3.05 / 170.66 2 14
6 13 55.64 18 15.26 383 105 3.16 / 170.76 2 7
7 8 0.04 165 15.23 297 746 3.91 / 171.51 2 26
Average= 3.81
(KJ/cycle)

Cycle 43 GMT 3/ 1/2024 4:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 29 15.19 436 192 0.19 / 164.04 2 3
2 7 2008.44 38 14.82 2868 1615 1.81 / 165.65 2 6
3 13 1331.12 18 14.95 2079 559 2.37 / 166.21 2 11
4 13 795.52 18 15.08 1417 385 2.75 / 166.60 2 13
5 13 247.88 18 15.23 667 183 2.93 / 166.78 2 13
6 13 62.36 18 15.26 387 106 3.04 / 166.89 2 7
7 8 -0.12 165 15.23 285 716 3.76 / 167.60 2 9
Average= 3.81
(KJ/cycle)

Cycle 42 GMT 24/12/2023 8:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 30 15.20 421 192 0.19 / 160.18 2 3
2 7 2003.68 38 14.84 2878 1623 1.81 / 161.81 2 6
3 13 1403.08 18 14.96 2171 585 2.40 / 162.39 2 10
4 13 824.48 18 15.09 1451 394 2.79 / 162.79 2 13
5 13 310.20 18 15.22 763 209 3.00 / 163.00 2 14
6 13 61.24 18 15.26 393 108 3.11 / 163.10 2 15
7 8 0.12 165 15.24 295 742 3.85 / 163.85 2 24
Average= 3.81
(KJ/cycle)

Cycle 41 GMT 14/12/2023 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 15.19 435 192 0.19 / 156.39 2 3
2 7 2005.48 38 14.82 2885 1625 1.82 / 158.01 2 8
3 13 1273.88 18 14.98 2014 543 2.36 / 158.56 2 11
4 13 831.64 18 15.07 1466 398 2.76 / 158.95 2 12
5 13 312.52 18 15.21 767 210 2.97 / 159.16 2 14
6 13 49.96 18 15.27 367 101 3.07 / 159.26 2 15
7 8 0.08 165 15.24 290 729 3.80 / 159.99 2 27
Average= 3.81
(KJ/cycle)

Cycle 40 GMT 4/12/2023 18:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 29 15.19 462 204 0.20 / 152.54 2 3
2 7 2004.76 38 14.83 2883 1625 1.83 / 154.17 2 7
3 13 1432.08 18 14.95 2215 596 2.42 / 154.76 2 10
4 13 825.08 18 15.08 1456 395 2.82 / 155.16 2 13
5 13 275.76 18 15.23 715 196 3.02 / 155.36 2 13
6 13 46.72 18 15.27 369 101 3.12 / 155.46 2 7
7 8 0.04 165 15.24 294 739 3.86 / 156.20 2 8
Average= 3.81
(KJ/cycle)

Cycle 39 GMT 24/11/2023 23:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 29 15.20 463 204 0.20 / 148.71 2 3
2 7 2003.48 38 14.83 2876 1621 1.82 / 150.33 2 7
3 13 1359.84 18 14.95 2115 569 2.39 / 150.90 2 11
4 13 864.04 18 15.05 1509 409 2.80 / 151.31 2 12
5 13 262.24 18 15.23 685 188 2.99 / 151.50 2 13
6 13 61.40 18 15.26 386 106 3.10 / 151.60 2 9
7 8 0.00 165 15.24 293 737 3.83 / 152.34 2 26
Average= 3.81
(KJ/cycle)

Cycle 38 GMT 15/11/2023 4:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 29 15.20 428 189 0.19 / 144.82 2 3
2 7 2002.96 38 14.83 2879 1622 1.81 / 146.44 2 7
3 13 1391.16 18 14.95 2146 577 2.39 / 147.02 2 10
4 13 929.24 18 15.05 1586 430 2.82 / 147.45 2 13
5 13 297.60 18 15.23 748 205 3.02 / 147.65 2 13
6 13 54.28 18 15.27 380 104 3.13 / 147.76 2 6
7 8 -0.04 165 15.24 297 747 3.87 / 148.51 2 18
Average= 3.81
(KJ/cycle)

Cycle 37 GMT 5/11/2023 9:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 29 15.19 448 197 0.20 / 140.96 2 3
2 7 2007.08 38 14.82 2894 1630 1.83 / 142.59 2 7
3 13 1361.88 18 14.95 2130 573 2.40 / 143.16 2 11
4 13 869.92 18 15.06 1514 410 2.81 / 143.57 2 13
5 13 304.04 18 15.23 758 208 3.02 / 143.78 2 14
6 13 53.12 18 15.27 381 105 3.12 / 143.88 2 8
7 8 -0.08 165 15.24 298 749 3.87 / 144.63 2 26
Average= 3.81
(KJ/cycle)

Cycle 36 GMT 26/10/2023 14: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 29 15.20 436 192 0.19 / 137.15 2 3
2 7 2007.20 38 14.84 2884 1626 1.82 / 138.78 2 8
3 13 1325.00 18 14.97 2078 560 2.38 / 139.34 2 10
4 13 786.24 18 15.08 1415 384 2.76 / 139.72 2 12
5 13 287.72 18 15.22 731 200 2.96 / 139.92 2 13
6 13 45.00 18 15.26 370 102 3.06 / 140.03 2 8
7 8 0.16 165 15.23 292 734 3.80 / 140.76 2 12
Average= 3.80
(KJ/cycle)

Cycle 35 GMT 16/10/2023 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 29 15.20 451 199 0.20 / 133.30 2 3
2 7 2012.28 38 14.83 2890 1629 1.83 / 134.93 2 8
3 13 1384.20 18 14.96 2164 583 2.41 / 135.52 2 10
4 13 804.88 18 15.09 1435 390 2.80 / 135.91 2 13
5 13 305.68 18 15.22 757 207 3.01 / 136.11 2 13
6 13 60.40 18 15.27 387 106 3.11 / 136.22 2 9
7 8 0.04 165 15.24 295 742 3.86 / 136.96 2 18
Average= 3.80
(KJ/cycle)

Cycle 34 GMT 6/10/2023 23:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 29 15.21 423 187 0.19 / 129.45 2 3
2 7 2004.16 38 14.82 2873 1618 1.80 / 131.07 2 8
3 13 1313.36 18 14.97 2079 560 2.36 / 131.63 2 10
4 13 862.92 18 15.06 1506 408 2.77 / 132.04 2 12
5 13 329.88 18 15.20 793 217 2.99 / 132.26 2 14
6 13 66.64 18 15.27 396 109 3.10 / 132.37 2 14
7 8 0.00 165 15.24 294 739 3.84 / 133.11 2 28
Average= 3.80
(KJ/cycle)

Cycle 33 GMT 27/ 9/2023 4:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 29 15.21 440 194 0.19 / 125.65 2 3
2 7 2003.92 38 14.84 2885 1627 1.82 / 127.28 2 7
3 13 1346.96 18 14.97 2101 566 2.39 / 127.85 2 10
4 13 806.32 18 15.09 1436 390 2.78 / 128.24 2 13
5 13 265.32 18 15.24 693 190 2.97 / 128.43 2 13
6 13 66.64 18 15.28 396 109 3.08 / 128.53 2 11
7 8 -0.08 165 15.25 291 732 3.81 / 129.27 2 15
Average= 3.80
(KJ/cycle)

Cycle 32 GMT 17/ 9/2023 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 29 15.22 457 202 0.20 / 121.79 2 3
2 7 2006.80 38 14.85 2880 1625 1.83 / 123.41 2 8
3 13 1498.88 18 14.96 2281 614 2.44 / 124.03 2 10
4 13 766.60 18 15.12 1384 377 2.82 / 124.40 2 13
5 13 324.16 18 15.23 776 213 3.03 / 124.62 2 13
6 13 67.72 18 15.29 398 110 3.14 / 124.73 2 9
7 8 0.08 165 15.26 291 733 3.87 / 125.46 2 22
Average= 3.80
(KJ/cycle)

Cycle 31 GMT 7/ 9/2023 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 29 15.20 442 195 0.19 / 117.95 2 3
2 7 2010.72 38 14.85 2898 1635 1.83 / 119.59 2 8
3 13 1450.68 18 14.97 2235 602 2.43 / 120.19 2 10
4 13 723.40 18 15.13 1324 361 2.79 / 120.55 2 13
5 13 289.80 18 15.25 730 200 2.99 / 120.75 2 13
6 13 50.48 18 15.29 361 99 3.09 / 120.85 2 10
7 8 -0.08 165 15.26 293 738 3.83 / 121.59 2 20
Average= 3.80
(KJ/cycle)

Cycle 30 GMT 28/ 8/2023 18:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 29 15.21 465 205 0.21 / 114.15 2 3
2 7 2010.72 38 14.84 2898 1634 1.84 / 115.78 2 8
3 13 1356.96 18 14.98 2126 573 2.41 / 116.35 2 10
4 13 773.84 18 15.10 1393 379 2.79 / 116.73 2 13
5 13 276.40 18 15.24 707 194 2.99 / 116.93 2 13
6 13 14.56 18 15.29 322 89 3.07 / 117.02 2 5
7 8 0.00 165 15.25 294 740 3.81 / 117.76 2 22
Average= 3.80
(KJ/cycle)

Cycle 29 GMT 18/ 8/2023 23:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 15.21 435 192 0.19 / 110.30 2 3
2 7 2006.16 38 14.84 2888 1629 1.82 / 111.92 2 7
3 13 1328.48 18 14.98 2081 561 2.38 / 112.49 2 10
4 13 783.12 18 15.11 1407 383 2.76 / 112.87 2 13
5 13 316.84 18 15.22 792 217 2.98 / 113.09 2 14
6 13 47.52 18 15.29 378 104 3.09 / 113.19 2 8
7 8 0.28 165 15.25 299 752 3.84 / 113.94 2 14
Average= 3.80
(KJ/cycle)

Cycle 28 GMT 9/ 8/2023 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 29 15.21 445 196 0.20 / 106.43 2 3
2 7 2006.08 38 14.85 2898 1635 1.83 / 108.06 2 8
3 13 1381.36 18 14.99 2162 583 2.41 / 108.65 2 11
4 13 880.20 18 15.09 1533 416 2.83 / 109.06 2 13
5 13 306.88 18 15.24 755 207 3.04 / 109.27 2 14
6 13 53.76 18 15.28 381 105 3.14 / 109.37 2 12
7 8 0.00 165 15.25 290 730 3.87 / 110.10 2 20
Average= 3.80
(KJ/cycle)

Cycle 27 GMT 30/ 7/2023 9:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 29 15.21 440 194 0.19 / 102.59 2 3
2 7 2011.48 38 14.85 2884 1627 1.82 / 104.22 2 8
3 13 1346.04 18 15.00 2110 570 2.39 / 104.79 2 10
4 13 841.48 18 15.10 1483 403 2.79 / 105.19 2 13
5 13 316.60 18 15.24 767 210 3.00 / 105.40 2 14
6 13 59.52 18 15.29 379 104 3.11 / 105.51 2 13
7 8 0.00 165 15.26 287 723 3.83 / 106.23 2 17
Average= 3.79
(KJ/cycle)

Cycle 26 GMT 20/ 7/2023 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 15.21 440 194 0.19 / 98.79 2 3
2 7 2010.16 38 14.85 2890 1631 1.82 / 100.42 2 8
3 13 1334.36 18 14.99 2086 563 2.39 / 100.98 2 11
4 13 843.72 18 15.09 1482 403 2.79 / 101.39 2 13
5 13 278.08 18 15.24 708 194 2.98 / 101.58 2 13
6 13 38.24 18 15.29 344 95 3.08 / 101.68 2 12
7 8 0.12 165 15.25 288 725 3.80 / 102.40 2 14
Average= 3.79
(KJ/cycle)

Cycle 25 GMT 10/ 7/2023 19: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 29 15.22 429 189 0.19 / 94.94 2 3
2 7 2005.68 38 14.86 2888 1631 1.82 / 96.57 2 8
3 13 1390.24 18 14.97 2177 587 2.41 / 97.16 2 11
4 13 815.60 18 15.10 1452 395 2.80 / 97.56 2 13
5 13 296.16 18 15.24 744 204 3.01 / 97.76 2 14
6 13 61.36 18 15.28 386 106 3.11 / 97.87 2 10
7 8 0.16 165 15.25 290 730 3.84 / 98.60 2 24
Average= 3.79
(KJ/cycle)

Cycle 24 GMT 1/ 7/2023 0: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 29 15.23 453 200 0.20 / 91.10 2 3
2 7 2007.36 38 14.86 2897 1636 1.84 / 92.74 2 8
3 13 1444.20 18 14.97 2245 605 2.44 / 93.34 2 10
4 13 754.56 18 15.12 1366 372 2.81 / 93.71 2 13
5 13 305.80 18 15.24 752 206 3.02 / 93.92 2 13
6 13 59.20 18 15.29 385 106 3.12 / 94.02 2 10
7 8 0.12 165 15.25 290 730 3.85 / 94.75 2 21
Average= 3.79
(KJ/cycle)

Cycle 23 GMT 21/ 6/2023 4:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 29 15.22 448 198 0.20 / 87.27 2 3
2 7 2006.28 38 14.85 2890 1631 1.83 / 88.90 2 8
3 13 1360.24 18 14.99 2125 573 2.40 / 89.48 2 11
4 13 770.68 18 15.12 1375 374 2.78 / 89.85 2 13
5 13 305.28 18 15.23 751 206 2.98 / 90.06 2 14
6 13 41.84 18 15.29 362 100 3.08 / 90.16 2 10
7 8 0.00 165 15.25 296 745 3.83 / 90.90 2 14
Average= 3.79
(KJ/cycle)

Cycle 22 GMT 11/ 6/2023 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 29 15.23 450 199 0.20 / 83.46 2 3
2 7 2005.76 38 14.86 2886 1630 1.83 / 85.09 2 8
3 13 1314.00 18 15.00 2075 560 2.39 / 85.65 2 11
4 13 783.56 18 15.13 1405 383 2.77 / 86.04 2 13
5 13 273.96 18 15.26 710 195 2.97 / 86.23 2 14
6 13 35.24 18 15.30 350 96 3.06 / 86.33 2 10
7 8 0.12 165 15.26 296 745 3.81 / 87.07 2 13
Average= 3.79
(KJ/cycle)

Cycle 21 GMT 1/ 6/2023 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 29 15.23 432 191 0.19 / 79.64 2 3
2 7 2011.44 38 14.87 2903 1640 1.83 / 81.28 2 8
3 13 1277.20 18 15.03 2034 550 2.38 / 81.83 2 11
4 13 838.24 18 15.11 1473 401 2.78 / 82.23 2 13
5 13 271.00 18 15.27 703 193 2.98 / 82.42 2 14
6 13 51.08 18 15.30 371 102 3.08 / 82.52 2 8
7 8 -0.08 165 15.27 295 743 3.82 / 83.27 2 14
Average= 3.78
(KJ/cycle)

Cycle 20 GMT 22/ 5/2023 19: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 29 15.23 440 194 0.19 / 75.76 2 2
2 7 2005.00 39 14.87 2893 1678 1.87 / 77.43 2 8
3 13 1349.32 18 15.01 2105 569 2.44 / 78.00 2 10
4 13 898.00 18 15.09 1549 421 2.86 / 78.42 2 13
5 13 267.16 18 15.26 696 191 3.05 / 78.61 2 13
6 13 42.28 18 15.30 355 98 3.15 / 78.71 2 9
7 8 0.12 165 15.26 291 733 3.88 / 79.44 2 17
Average= 3.78
(KJ/cycle)

Cycle 19 GMT 12/ 5/2023 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 29 15.24 445 197 0.20 / 71.93 2 3
2 7 2009.76 38 14.88 2894 1636 1.83 / 73.57 2 7
3 13 1320.48 18 15.01 2087 564 2.40 / 74.13 2 10
4 13 819.60 18 15.13 1451 395 2.79 / 74.53 2 13
5 13 289.48 18 15.27 725 199 2.99 / 74.73 2 14
6 13 46.24 18 15.31 361 99 3.09 / 74.83 2 10
7 8 -0.04 165 15.28 292 736 3.83 / 75.56 2 20
Average= 3.78
(KJ/cycle)

Cycle 18 GMT 3/ 5/2023 4:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 29 15.23 425 188 0.19 / 68.13 2 3
2 7 2005.52 38 14.88 2903 1641 1.83 / 69.77 2 7
3 13 1230.48 18 15.04 1957 530 2.36 / 70.30 2 11
4 13 752.68 18 15.14 1363 371 2.73 / 70.67 2 13
5 13 292.24 18 15.26 740 203 2.93 / 70.87 2 13
6 13 46.76 18 15.30 372 102 3.04 / 70.98 2 9
7 8 0.08 165 15.27 301 758 3.79 / 71.73 2 18
Average= 3.78
(KJ/cycle)

Cycle 17 GMT 23/ 4/2023 9:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.76 29 15.24 464 205 0.21 / 64.31 2 3
2 7 2008.88 38 14.89 2894 1637 1.84 / 65.95 2 8
3 13 1306.56 18 15.04 2072 561 2.40 / 66.51 2 10
4 13 776.40 18 15.14 1400 382 2.79 / 66.89 2 13
5 13 274.32 18 15.28 704 194 2.98 / 67.09 2 14
6 13 66.28 18 15.31 391 108 3.09 / 67.19 2 12
7 8 0.08 165 15.27 296 746 3.83 / 67.94 2 22
Average= 3.77
(KJ/cycle)

Cycle 16 GMT 13/ 4/2023 13:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 29 15.25 442 195 0.20 / 60.45 2 3
2 7 2010.96 38 14.91 2899 1643 1.84 / 62.09 2 8
3 13 1389.96 18 15.03 2168 587 2.42 / 62.68 2 10
4 13 793.80 18 15.14 1439 392 2.82 / 63.07 2 13
5 13 279.96 18 15.28 719 198 3.01 / 63.27 2 13
6 13 41.96 18 15.33 358 99 3.11 / 63.37 2 10
7 8 -0.04 165 15.29 294 742 3.85 / 64.11 2 14
Average= 3.77
(KJ/cycle)

Cycle 15 GMT 3/ 4/2023 18:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 29 15.25 439 194 0.19 / 56.59 2 3
2 7 2005.36 38 14.90 2882 1632 1.83 / 58.22 2 7
3 13 1344.48 18 15.04 2125 575 2.40 / 58.80 2 10
4 13 793.52 18 15.14 1418 386 2.79 / 59.18 2 13
5 13 376.72 18 15.25 856 235 3.02 / 59.42 2 14
6 13 48.68 18 15.33 366 101 3.12 / 59.52 2 12
7 8 0.16 165 15.30 291 735 3.86 / 60.25 2 15
Average= 3.77
(KJ/cycle)

Cycle 14 GMT 24/ 3/2023 23:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 29 15.27 459 203 0.20 / 52.81 2 3
2 7 2006.00 38 14.91 2900 1643 1.85 / 54.45 2 7
3 13 1346.80 18 15.03 2102 569 2.42 / 55.02 2 11
4 13 683.96 18 15.19 1272 348 2.76 / 55.37 2 13
5 13 259.56 18 15.30 680 187 2.95 / 55.55 2 12
6 13 57.96 18 15.31 378 104 3.05 / 55.66 2 9
7 8 0.16 165 15.29 292 737 3.79 / 56.39 2 17
Average= 3.76
(KJ/cycle)

Cycle 13 GMT 15/ 3/2023 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 29 15.26 450 199 0.20 / 48.97 2 3
2 7 2004.36 38 14.92 2895 1641 1.84 / 50.61 2 7
3 13 1313.60 18 15.07 2083 565 2.41 / 51.18 2 10
4 13 823.60 18 15.17 1467 401 2.81 / 51.58 2 13
5 13 270.24 18 15.31 698 192 3.00 / 51.77 2 13
6 13 38.48 18 15.34 357 99 3.10 / 51.87 2 8
7 8 0.04 165 15.31 290 733 3.83 / 52.60 2 11
Average= 3.76
(KJ/cycle)

Cycle 12 GMT 5/ 3/2023 9:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 29 15.26 469 208 0.21 / 45.10 2 3
2 7 2008.68 38 14.91 2890 1637 1.84 / 46.73 2 7
3 13 1331.68 18 15.05 2097 568 2.41 / 47.30 2 10
4 13 851.20 18 15.13 1498 408 2.82 / 47.71 2 13
5 13 364.96 18 15.26 844 232 3.05 / 47.94 2 14
6 13 48.40 18 15.33 363 100 3.15 / 48.04 2 12
7 8 0.16 165 15.31 290 733 3.89 / 48.77 2 22
Average= 3.75
(KJ/cycle)

Cycle 11 GMT 23/ 2/2023 14: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 28 15.26 461 197 0.20 / 41.29 2 3
2 7 2004.52 38 14.92 2890 1639 1.84 / 42.93 2 7
3 13 1218.32 18 15.07 1964 533 2.37 / 43.46 2 11
4 13 741.60 18 15.17 1368 374 2.74 / 43.84 2 14
5 13 282.80 18 15.29 733 202 2.94 / 44.04 2 13
6 13 38.72 18 15.33 354 98 3.04 / 44.14 2 8
7 8 0.08 165 15.30 298 752 3.79 / 44.89 2 14
Average= 3.74
(KJ/cycle)

Cycle 10 GMT 13/ 2/2023 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 28 15.25 448 191 0.19 / 37.48 2 3
2 7 2007.68 38 14.92 2899 1644 1.83 / 39.12 2 6
3 13 1284.76 18 15.07 2044 554 2.39 / 39.68 2 11
4 13 724.64 18 15.19 1336 365 2.75 / 40.04 2 12
5 13 268.04 18 15.29 705 194 2.95 / 40.24 2 14
6 13 26.60 18 15.34 345 95 3.04 / 40.33 2 13
7 8 0.04 165 15.30 302 762 3.81 / 41.09 2 17
Average= 3.74
(KJ/cycle)

Cycle 9 GMT 3/ 2/2023 23:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 28 15.27 435 186 0.19 / 33.71 2 3
2 7 2011.52 38 14.91 2909 1648 1.83 / 35.36 2 7
3 13 1282.32 18 15.05 2038 552 2.39 / 35.91 2 11
4 13 706.68 18 15.18 1315 359 2.75 / 36.27 2 13
5 13 210.68 18 15.30 619 170 2.92 / 36.44 2 13
6 13 23.52 18 15.33 335 92 3.01 / 36.53 2 7
7 8 0.04 165 15.30 299 755 3.76 / 37.29 2 14
Average= 3.73
(KJ/cycle)

Cycle 8 GMT 25/ 1/2023 4:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 28 15.27 460 197 0.20 / 29.30 2 3
2 7 2008.36 74 14.80 2879 3153 3.35 / 32.45 2 9
3 13 380.04 18 15.28 859 236 3.59 / 32.69 2 13
4 13 62.00 18 15.34 383 106 3.69 / 32.79 2 12
5 8 0.12 165 15.31 290 733 4.42 / 33.53 2 14
Average= 3.73
(KJ/cycle)

Cycle 7 GMT 15/ 1/2023 7: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 28 15.26 441 188 0.19 / 24.80 2 3
2 3 1022.80 1 15.31 1820 28 0.22 / 24.82 2 8
3 7 2008.96 74 14.81 2889 3166 3.38 / 27.99 2 8
4 13 486.44 18 15.24 1001 275 3.66 / 28.27 2 14
5 13 55.12 18 15.34 373 103 3.76 / 28.37 2 10
6 8 0.16 165 15.31 290 733 4.49 / 29.10 2 23
Average= 3.64
(KJ/cycle)

Cycle 6 GMT 5/ 1/2023 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 26 15.27 438 174 0.17 / 20.30 2 3
2 10 1027.56 2 15.28 1747 53 0.23 / 20.36 2 5
3 7 2013.32 74 14.81 2894 3172 3.40 / 23.53 2 8
4 13 403.60 18 15.27 889 244 3.64 / 23.77 2 14
5 13 82.44 18 15.33 412 114 3.76 / 23.89 2 9
6 8 0.04 165 15.32 286 723 4.48 / 24.61 2 18
Average= 3.52
(KJ/cycle)

Cycle 5 GMT 26/12/2022 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 29 15.27 431 191 0.19 / 15.86 2 2
2 3 918.56 -2 15.66 0 0 0.00 / 15.86 2 2
3 7 2004.88 75 14.82 2876 3197 3.39 / 19.06 2 9
4 13 360.60 18 15.29 825 227 3.61 / 19.28 2 14
5 13 72.84 18 15.34 400 110 3.73 / 19.39 2 10
6 8 0.36 165 15.31 291 735 4.46 / 20.13 2 14
Average= 3.35
(KJ/cycle)

Cycle 4 GMT 16/12/2022 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 26 15.28 430 171 0.17 / 12.02 2 2
2 3 1024.84 1 15.32 1788 27 0.20 / 12.05 2 5
3 7 1518.68 75 15.00 2297 2584 2.78 / 14.63 2 7
4 13 266.00 18 15.32 699 193 2.98 / 14.83 2 12
5 13 30.48 18 15.36 343 95 3.07 / 14.92 2 10
6 8 0.12 165 15.32 295 746 3.82 / 15.67 2 15
Average= 3.13
(KJ/cycle)

Cycle 3 GMT 15/12/2022 15:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 23 15.29 435 153 0.15 / 8.24 2 3
2 10 1020.92 2 15.29 1747 53 0.21 / 8.30 2 4
3 3 1039.16 1 15.31 1798 28 0.23 / 8.33 2 7
4 7 1506.96 74 15.01 2276 2528 2.76 / 10.85 2 7
5 13 256.28 18 15.34 670 185 2.95 / 11.04 2 11
6 13 31.04 18 15.37 335 93 3.04 / 11.13 2 10
7 8 -0.16 165 15.33 285 721 3.76 / 11.85 2 16
Average= 2.96
(KJ/cycle)

Cycle 2 GMT 14/12/2022 16:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 31 15.33 460 219 0.22 / 4.54 2 3
2 3 798.20 -4 15.70 0 0 0.00 / 4.54 2 3
3 3 892.96 -2 15.71 0 0 0.00 / 4.54 2 3
4 7 1518.36 74 15.01 2291 2545 2.76 / 7.08 2 8
5 13 259.48 18 15.33 678 187 2.95 / 7.27 2 12
6 13 49.72 18 15.36 358 99 3.05 / 7.37 2 9
7 8 0.04 165 15.33 287 726 3.78 / 8.09 2 14
Average= 2.70
(KJ/cycle)

Cycle 1 GMT 13/12/2022 16:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 26 15.52 412 166 0.17 / 1.74 3 3
2 7 985.72 75 15.20 1623 1850 2.02 / 3.59 2 10
3 8 0.08 165 15.39 287 729 2.75 / 4.32 2 16
Average= 2.16
(KJ/cycle)

Cycle 0 GMT 13/12/2022 6:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 26 15.65 422 172 0.17 / 0.17 3 3
2 7 135.12 74 15.62 434 502 0.67 / 0.67 3 3
3 8 0.32 240 15.59 240 898 1.57 / 1.57 3 15
Average= 1.57
(KJ/cycle)