SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 32 | 15.05 | 454 | 219 | 0.22 / 300.98 | 2 | 2 |
2 | 7 | 2004.28 | 38 | 14.70 | 2939 | 1642 | 1.86 / 302.62 | 2 | 2 |
3 | 13 | 1369.28 | 18 | 14.79 | 2185 | 582 | 2.44 / 303.20 | 2 | 2 |
4 | 13 | 878.80 | 18 | 14.87 | 1542 | 413 | 2.85 / 303.62 | 2 | 2 |
5 | 13 | 334.24 | 18 | 15.04 | 798 | 216 | 3.07 / 303.83 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.08 | 302 | 751 | 3.82 / 304.58 | 2 | 3 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 32 | 15.06 | 440 | 212 | 0.21 / 297.16 | 2 | 2 |
2 | 7 | 2004.68 | 38 | 14.68 | 2940 | 1640 | 1.85 / 298.80 | 2 | 2 |
3 | 13 | 1328.24 | 18 | 14.80 | 2130 | 567 | 2.42 / 299.37 | 2 | 2 |
4 | 13 | 895.84 | 18 | 14.87 | 1564 | 419 | 2.84 / 299.79 | 2 | 2 |
5 | 13 | 355.44 | 18 | 15.03 | 821 | 222 | 3.06 / 300.01 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.09 | 302 | 752 | 3.81 / 300.76 | 2 | 4 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 32 | 15.06 | 463 | 223 | 0.22 / 293.29 | 2 | 2 |
2 | 7 | 2004.08 | 38 | 14.69 | 2941 | 1642 | 1.86 / 294.93 | 2 | 2 |
3 | 13 | 1441.16 | 18 | 14.78 | 2267 | 603 | 2.47 / 295.53 | 2 | 2 |
4 | 13 | 890.08 | 18 | 14.88 | 1565 | 419 | 2.89 / 295.95 | 2 | 3 |
5 | 13 | 389.52 | 18 | 15.03 | 884 | 239 | 3.13 / 296.19 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.10 | 305 | 760 | 3.89 / 296.95 | 2 | 6 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 32 | 15.06 | 466 | 225 | 0.22 / 289.47 | 2 | 2 |
2 | 7 | 2010.12 | 38 | 14.69 | 2952 | 1648 | 1.87 / 291.11 | 2 | 2 |
3 | 13 | 1322.16 | 18 | 14.81 | 2126 | 567 | 2.44 / 291.68 | 2 | 2 |
4 | 13 | 810.08 | 18 | 14.91 | 1461 | 392 | 2.83 / 292.07 | 2 | 2 |
5 | 13 | 383.68 | 18 | 15.04 | 863 | 234 | 3.06 / 292.31 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.10 | 304 | 757 | 3.82 / 293.06 | 2 | 3 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 32 | 15.05 | 469 | 226 | 0.23 / 285.62 | 2 | 2 |
2 | 7 | 2011.96 | 38 | 14.70 | 2934 | 1639 | 1.86 / 287.26 | 2 | 2 |
3 | 13 | 1342.56 | 18 | 14.81 | 2147 | 572 | 2.44 / 287.84 | 2 | 2 |
4 | 13 | 916.04 | 18 | 14.88 | 1597 | 428 | 2.86 / 288.26 | 2 | 2 |
5 | 13 | 330.60 | 18 | 15.06 | 793 | 215 | 3.08 / 288.48 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.10 | 306 | 762 | 3.84 / 289.24 | 2 | 7 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 32 | 15.07 | 447 | 216 | 0.22 / 281.69 | 2 | 2 |
2 | 7 | 2006.20 | 38 | 14.69 | 2941 | 1642 | 1.86 / 283.34 | 2 | 2 |
3 | 13 | 1286.92 | 18 | 14.81 | 2065 | 550 | 2.41 / 283.89 | 2 | 2 |
4 | 13 | 856.00 | 18 | 14.91 | 1524 | 409 | 2.82 / 284.30 | 2 | 2 |
5 | 13 | 401.60 | 18 | 15.04 | 902 | 244 | 3.06 / 284.54 | 2 | 3 |
6 | 13 | 29.44 | 18 | 15.13 | 351 | 96 | 3.16 / 284.64 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.10 | 306 | 762 | 3.92 / 285.40 | 2 | 10 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 31 | 15.06 | 467 | 218 | 0.22 / 277.88 | 2 | 2 |
2 | 7 | 2004.60 | 38 | 14.70 | 2921 | 1632 | 1.85 / 279.51 | 2 | 2 |
3 | 13 | 1359.52 | 18 | 14.81 | 2140 | 570 | 2.42 / 280.08 | 2 | 2 |
4 | 13 | 911.88 | 18 | 14.90 | 1553 | 417 | 2.84 / 280.50 | 2 | 2 |
5 | 13 | 358.04 | 18 | 15.06 | 802 | 217 | 3.05 / 280.72 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.11 | 306 | 763 | 3.82 / 281.48 | 2 | 5 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 31 | 15.08 | 465 | 217 | 0.22 / 273.96 | 2 | 2 |
2 | 7 | 2005.24 | 38 | 14.71 | 2932 | 1639 | 1.86 / 275.60 | 2 | 2 |
3 | 13 | 1399.76 | 18 | 14.82 | 2176 | 580 | 2.44 / 276.18 | 2 | 2 |
4 | 13 | 868.16 | 18 | 14.92 | 1506 | 404 | 2.84 / 276.58 | 2 | 3 |
5 | 13 | 372.20 | 18 | 15.05 | 852 | 231 | 3.07 / 276.82 | 2 | 2 |
6 | 13 | 16.80 | 18 | 15.14 | 327 | 89 | 3.16 / 276.90 | 2 | 4 |
7 | 8 | -0.16 | 165 | 15.10 | 304 | 757 | 3.92 / 277.66 | 2 | 6 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 31 | 15.07 | 444 | 207 | 0.21 / 270.07 | 2 | 2 |
2 | 7 | 2011.80 | 38 | 14.70 | 2950 | 1648 | 1.86 / 271.72 | 2 | 2 |
3 | 13 | 1455.08 | 18 | 14.80 | 2291 | 610 | 2.47 / 272.33 | 2 | 2 |
4 | 13 | 862.64 | 18 | 14.91 | 1532 | 411 | 2.88 / 272.74 | 2 | 2 |
5 | 13 | 416.76 | 18 | 15.04 | 917 | 248 | 3.13 / 272.99 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.11 | 302 | 753 | 3.88 / 273.74 | 2 | 4 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.72 | 31 | 15.07 | 477 | 223 | 0.22 / 266.19 | 2 | 2 |
2 | 7 | 2013.84 | 38 | 14.70 | 2957 | 1652 | 1.87 / 267.84 | 2 | 2 |
3 | 13 | 1414.80 | 18 | 14.80 | 2230 | 594 | 2.47 / 268.44 | 2 | 2 |
4 | 13 | 930.08 | 18 | 14.90 | 1617 | 434 | 2.90 / 268.87 | 2 | 2 |
5 | 13 | 377.36 | 18 | 15.05 | 868 | 235 | 3.14 / 269.11 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.11 | 305 | 760 | 3.90 / 269.87 | 2 | 3 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 31 | 15.08 | 442 | 207 | 0.21 / 262.26 | 2 | 2 |
2 | 7 | 2011.12 | 38 | 14.69 | 2952 | 1648 | 1.85 / 263.91 | 2 | 2 |
3 | 13 | 1366.16 | 18 | 14.80 | 2175 | 579 | 2.43 / 264.49 | 2 | 2 |
4 | 13 | 846.36 | 18 | 14.92 | 1501 | 403 | 2.84 / 264.89 | 2 | 2 |
5 | 13 | 354.80 | 18 | 15.07 | 834 | 226 | 3.06 / 265.12 | 2 | 2 |
6 | 13 | 28.40 | 18 | 15.15 | 346 | 94 | 3.16 / 265.21 | 2 | 4 |
7 | 8 | 0.32 | 165 | 15.12 | 303 | 756 | 3.91 / 265.97 | 2 | 11 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 31 | 15.08 | 472 | 221 | 0.22 / 258.30 | 2 | 2 |
2 | 7 | 2005.88 | 38 | 14.72 | 2928 | 1638 | 1.86 / 259.94 | 2 | 2 |
3 | 13 | 1414.76 | 18 | 14.83 | 2209 | 590 | 2.45 / 260.53 | 2 | 2 |
4 | 13 | 842.00 | 18 | 14.94 | 1474 | 396 | 2.84 / 260.93 | 2 | 3 |
5 | 13 | 407.08 | 18 | 15.05 | 911 | 247 | 3.09 / 261.17 | 2 | 3 |
6 | 13 | 66.92 | 18 | 15.14 | 402 | 110 | 3.20 / 261.28 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.12 | 309 | 771 | 3.97 / 262.05 | 2 | 5 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 31 | 15.09 | 446 | 209 | 0.21 / 254.30 | 2 | 2 |
2 | 7 | 2012.12 | 38 | 14.70 | 2955 | 1651 | 1.86 / 255.95 | 2 | 2 |
3 | 13 | 1367.12 | 18 | 14.82 | 2181 | 582 | 2.44 / 256.53 | 2 | 2 |
4 | 13 | 848.68 | 18 | 14.92 | 1523 | 409 | 2.85 / 256.94 | 2 | 3 |
5 | 13 | 405.76 | 18 | 15.06 | 915 | 248 | 3.10 / 257.19 | 2 | 3 |
6 | 13 | 104.88 | 18 | 15.13 | 460 | 125 | 3.22 / 257.31 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.11 | 308 | 768 | 3.99 / 258.08 | 2 | 12 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 31 | 15.09 | 449 | 210 | 0.21 / 250.30 | 2 | 2 |
2 | 7 | 2012.88 | 38 | 14.71 | 2958 | 1653 | 1.86 / 251.96 | 2 | 2 |
3 | 13 | 1368.44 | 18 | 14.82 | 2175 | 580 | 2.44 / 252.54 | 2 | 2 |
4 | 13 | 961.44 | 18 | 14.90 | 1655 | 444 | 2.89 / 252.98 | 2 | 2 |
5 | 13 | 384.60 | 18 | 15.07 | 876 | 238 | 3.13 / 253.22 | 2 | 3 |
6 | 13 | 35.52 | 18 | 15.16 | 362 | 99 | 3.22 / 253.32 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.12 | 310 | 773 | 4.00 / 254.09 | 2 | 6 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 31 | 15.10 | 455 | 213 | 0.21 / 246.40 | 2 | 2 |
2 | 7 | 2009.52 | 38 | 14.70 | 2953 | 1650 | 1.86 / 248.05 | 2 | 2 |
3 | 13 | 1303.96 | 18 | 14.83 | 2102 | 561 | 2.42 / 248.61 | 2 | 2 |
4 | 13 | 922.36 | 18 | 14.91 | 1611 | 432 | 2.86 / 249.04 | 2 | 2 |
5 | 13 | 298.52 | 18 | 15.10 | 752 | 204 | 3.06 / 249.25 | 2 | 2 |
6 | 13 | 15.04 | 18 | 15.17 | 327 | 89 | 3.15 / 249.33 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.13 | 304 | 759 | 3.91 / 250.09 | 2 | 7 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 31 | 15.10 | 463 | 217 | 0.22 / 242.34 | 2 | 2 |
2 | 10 | 1011.80 | 2 | 15.12 | 1747 | 53 | 0.27 / 242.39 | 2 | 2 |
3 | 3 | 956.68 | -1 | 15.49 | 0 | 0 | 0.05 / 242.39 | 2 | 2 |
4 | 7 | 2003.96 | 38 | 14.72 | 2945 | 1647 | 1.92 / 244.04 | 2 | 2 |
5 | 13 | 1470.56 | 18 | 14.81 | 2318 | 618 | 2.53 / 244.66 | 2 | 2 |
6 | 13 | 837.84 | 18 | 14.95 | 1497 | 403 | 2.94 / 245.06 | 2 | 3 |
7 | 13 | 396.04 | 18 | 15.09 | 905 | 246 | 3.18 / 245.30 | 2 | 3 |
8 | 13 | 56.44 | 18 | 15.16 | 393 | 107 | 3.29 / 245.41 | 2 | 2 |
9 | 8 | 0.24 | 165 | 15.13 | 310 | 774 | 4.06 / 246.19 | 2 | 4 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 31 | 15.12 | 453 | 212 | 0.21 / 238.36 | 2 | 2 |
2 | 7 | 2008.00 | 38 | 14.71 | 2942 | 1645 | 1.86 / 240.00 | 2 | 2 |
3 | 13 | 1452.40 | 18 | 14.81 | 2295 | 612 | 2.47 / 240.61 | 2 | 2 |
4 | 13 | 855.08 | 18 | 14.95 | 1525 | 410 | 2.88 / 241.03 | 2 | 3 |
5 | 13 | 373.76 | 18 | 15.09 | 858 | 233 | 3.11 / 241.26 | 2 | 2 |
6 | 13 | 38.04 | 18 | 15.17 | 359 | 98 | 3.21 / 241.36 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.14 | 306 | 764 | 3.97 / 242.12 | 2 | 5 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 31 | 15.11 | 440 | 206 | 0.21 / 234.46 | 2 | 2 |
2 | 7 | 2003.40 | 38 | 14.72 | 2918 | 1632 | 1.84 / 236.09 | 2 | 2 |
3 | 13 | 1271.52 | 18 | 14.87 | 2019 | 540 | 2.38 / 236.63 | 2 | 2 |
4 | 13 | 857.36 | 18 | 14.95 | 1517 | 408 | 2.79 / 237.04 | 2 | 3 |
5 | 13 | 356.36 | 18 | 15.09 | 832 | 226 | 3.01 / 237.26 | 2 | 2 |
6 | 13 | 102.52 | 18 | 15.16 | 456 | 124 | 3.14 / 237.39 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.14 | 304 | 759 | 3.90 / 238.15 | 2 | 5 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 31 | 15.10 | 446 | 209 | 0.21 / 230.53 | 2 | 2 |
2 | 7 | 2012.24 | 38 | 14.72 | 2936 | 1642 | 1.85 / 232.18 | 2 | 2 |
3 | 13 | 1333.48 | 18 | 14.84 | 2130 | 569 | 2.42 / 232.74 | 2 | 2 |
4 | 13 | 853.72 | 18 | 14.96 | 1518 | 409 | 2.83 / 233.15 | 2 | 3 |
5 | 13 | 360.68 | 18 | 15.09 | 839 | 228 | 3.06 / 233.38 | 2 | 3 |
6 | 13 | 63.28 | 18 | 15.18 | 399 | 109 | 3.17 / 233.49 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.14 | 304 | 759 | 3.93 / 234.25 | 2 | 4 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 31 | 15.11 | 442 | 207 | 0.21 / 226.55 | 2 | 2 |
2 | 7 | 2005.60 | 39 | 14.73 | 2929 | 1683 | 1.89 / 228.23 | 2 | 2 |
3 | 13 | 1368.16 | 18 | 14.84 | 2186 | 584 | 2.47 / 228.82 | 2 | 2 |
4 | 13 | 890.92 | 18 | 14.95 | 1571 | 423 | 2.90 / 229.24 | 2 | 2 |
5 | 13 | 345.44 | 18 | 15.11 | 821 | 223 | 3.12 / 229.46 | 2 | 2 |
6 | 13 | 54.52 | 18 | 15.17 | 381 | 104 | 3.22 / 229.57 | 2 | 3 |
7 | 8 | 0.28 | 165 | 15.15 | 303 | 757 | 3.98 / 230.32 | 2 | 5 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 31 | 15.11 | 454 | 213 | 0.21 / 222.56 | 2 | 2 |
2 | 7 | 2004.16 | 38 | 14.73 | 2959 | 1656 | 1.87 / 224.22 | 2 | 2 |
3 | 13 | 1356.16 | 18 | 14.86 | 2172 | 581 | 2.45 / 224.80 | 2 | 2 |
4 | 13 | 921.88 | 18 | 14.94 | 1609 | 433 | 2.88 / 225.23 | 2 | 3 |
5 | 13 | 367.64 | 18 | 15.12 | 861 | 234 | 3.12 / 225.47 | 2 | 2 |
6 | 13 | 71.12 | 18 | 15.17 | 413 | 113 | 3.23 / 225.58 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.15 | 306 | 765 | 3.99 / 226.34 | 2 | 10 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 31 | 15.12 | 435 | 204 | 0.20 / 218.54 | 2 | 2 |
2 | 7 | 2010.28 | 38 | 14.73 | 2961 | 1657 | 1.86 / 220.20 | 2 | 2 |
3 | 13 | 1377.48 | 18 | 14.86 | 2200 | 588 | 2.45 / 220.78 | 2 | 2 |
4 | 13 | 937.04 | 18 | 14.94 | 1631 | 439 | 2.89 / 221.22 | 2 | 3 |
5 | 13 | 366.08 | 18 | 15.11 | 857 | 233 | 3.12 / 221.46 | 2 | 3 |
6 | 13 | 67.40 | 18 | 15.18 | 410 | 112 | 3.23 / 221.57 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.15 | 312 | 780 | 4.01 / 222.35 | 2 | 6 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 31 | 15.12 | 464 | 217 | 0.22 / 214.56 | 2 | 2 |
2 | 7 | 2007.28 | 38 | 14.72 | 2953 | 1652 | 1.87 / 216.21 | 2 | 2 |
3 | 13 | 1329.44 | 18 | 14.85 | 2139 | 572 | 2.44 / 216.78 | 2 | 2 |
4 | 13 | 924.00 | 18 | 14.94 | 1614 | 434 | 2.88 / 217.22 | 2 | 3 |
5 | 13 | 375.40 | 18 | 15.10 | 867 | 236 | 3.11 / 217.45 | 2 | 3 |
6 | 13 | 73.04 | 18 | 15.18 | 414 | 113 | 3.22 / 217.57 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.15 | 307 | 767 | 3.99 / 218.34 | 2 | 9 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 31 | 15.11 | 444 | 208 | 0.21 / 210.64 | 2 | 2 |
2 | 7 | 2003.36 | 38 | 14.73 | 2947 | 1650 | 1.86 / 212.28 | 2 | 2 |
3 | 13 | 1312.88 | 18 | 14.88 | 2125 | 569 | 2.43 / 212.85 | 2 | 2 |
4 | 13 | 824.92 | 18 | 14.97 | 1487 | 401 | 2.83 / 213.25 | 2 | 3 |
5 | 13 | 293.64 | 18 | 15.14 | 746 | 203 | 3.03 / 213.46 | 2 | 3 |
6 | 13 | 49.72 | 18 | 15.20 | 385 | 105 | 3.14 / 213.56 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.16 | 312 | 780 | 3.92 / 214.34 | 2 | 8 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 31 | 15.12 | 465 | 218 | 0.22 / 206.61 | 2 | 2 |
2 | 7 | 2005.88 | 39 | 14.74 | 2925 | 1681 | 1.90 / 208.29 | 2 | 2 |
3 | 13 | 1429.32 | 18 | 14.86 | 2231 | 597 | 2.50 / 208.89 | 2 | 2 |
4 | 13 | 832.32 | 18 | 14.98 | 1457 | 393 | 2.89 / 209.28 | 2 | 2 |
5 | 13 | 472.04 | 18 | 15.09 | 987 | 268 | 3.16 / 209.55 | 2 | 3 |
6 | 13 | 44.92 | 18 | 15.19 | 373 | 102 | 3.26 / 209.65 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.15 | 311 | 777 | 4.04 / 210.43 | 2 | 7 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 31 | 15.12 | 467 | 219 | 0.22 / 202.59 | 2 | 2 |
2 | 7 | 2004.80 | 38 | 14.74 | 2948 | 1651 | 1.87 / 204.24 | 2 | 2 |
3 | 13 | 1416.76 | 18 | 14.85 | 2249 | 601 | 2.47 / 204.84 | 2 | 2 |
4 | 13 | 929.40 | 18 | 14.95 | 1631 | 439 | 2.91 / 205.28 | 2 | 3 |
5 | 13 | 352.68 | 18 | 15.12 | 838 | 228 | 3.14 / 205.50 | 2 | 3 |
6 | 13 | 69.72 | 18 | 15.20 | 413 | 113 | 3.25 / 205.62 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.16 | 309 | 773 | 4.02 / 206.39 | 2 | 6 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 31 | 15.13 | 446 | 209 | 0.21 / 198.60 | 2 | 2 |
2 | 7 | 2003.08 | 38 | 14.75 | 2946 | 1651 | 1.86 / 200.25 | 2 | 2 |
3 | 13 | 1354.92 | 18 | 14.86 | 2167 | 580 | 2.44 / 200.83 | 2 | 2 |
4 | 13 | 925.04 | 18 | 14.95 | 1621 | 436 | 2.88 / 201.26 | 2 | 2 |
5 | 13 | 336.00 | 18 | 15.14 | 813 | 222 | 3.10 / 201.49 | 2 | 2 |
6 | 13 | 53.40 | 18 | 15.20 | 388 | 106 | 3.20 / 201.59 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.16 | 310 | 775 | 3.98 / 202.37 | 2 | 12 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 31 | 15.13 | 446 | 209 | 0.21 / 194.62 | 2 | 2 |
2 | 7 | 2004.52 | 39 | 14.73 | 2943 | 1691 | 1.90 / 196.31 | 2 | 2 |
3 | 13 | 1453.36 | 18 | 14.84 | 2287 | 611 | 2.51 / 196.92 | 2 | 2 |
4 | 13 | 817.20 | 18 | 14.99 | 1460 | 394 | 2.90 / 197.31 | 2 | 2 |
5 | 13 | 331.24 | 18 | 15.14 | 797 | 217 | 3.12 / 197.53 | 2 | 2 |
6 | 13 | 29.88 | 18 | 15.21 | 349 | 96 | 3.22 / 197.63 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.17 | 304 | 761 | 3.98 / 198.39 | 2 | 7 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 31 | 15.14 | 443 | 208 | 0.21 / 190.70 | 2 | 2 |
2 | 7 | 2012.08 | 38 | 14.76 | 2934 | 1646 | 1.85 / 192.34 | 2 | 2 |
3 | 13 | 1280.56 | 18 | 14.90 | 2069 | 555 | 2.41 / 192.90 | 2 | 2 |
4 | 13 | 858.60 | 18 | 15.00 | 1526 | 412 | 2.82 / 193.31 | 2 | 2 |
5 | 13 | 364.24 | 18 | 15.14 | 848 | 231 | 3.05 / 193.54 | 2 | 2 |
6 | 13 | 39.84 | 18 | 15.22 | 366 | 100 | 3.15 / 193.64 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.18 | 306 | 766 | 3.92 / 194.41 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 31 | 15.15 | 465 | 218 | 0.22 / 186.74 | 2 | 2 |
2 | 7 | 2005.20 | 38 | 14.76 | 2945 | 1652 | 1.87 / 188.39 | 2 | 2 |
3 | 13 | 1389.84 | 18 | 14.88 | 2213 | 593 | 2.46 / 188.99 | 2 | 2 |
4 | 13 | 819.36 | 18 | 15.01 | 1469 | 397 | 2.86 / 189.38 | 2 | 3 |
5 | 13 | 376.56 | 18 | 15.13 | 872 | 237 | 3.10 / 189.62 | 2 | 3 |
6 | 13 | 35.44 | 18 | 15.22 | 360 | 99 | 3.20 / 189.72 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.19 | 308 | 772 | 3.97 / 190.49 | 2 | 6 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 31 | 15.15 | 450 | 211 | 0.21 / 182.84 | 2 | 2 |
2 | 7 | 2005.20 | 38 | 14.76 | 2921 | 1638 | 1.85 / 184.48 | 2 | 2 |
3 | 13 | 1312.72 | 18 | 14.91 | 2070 | 556 | 2.41 / 185.04 | 2 | 2 |
4 | 13 | 873.36 | 18 | 15.00 | 1527 | 412 | 2.82 / 185.45 | 2 | 2 |
5 | 13 | 330.60 | 18 | 15.15 | 799 | 218 | 3.04 / 185.67 | 2 | 3 |
6 | 13 | 26.08 | 18 | 15.23 | 345 | 95 | 3.13 / 185.76 | 2 | 3 |
7 | 8 | -0.16 | 165 | 15.19 | 304 | 762 | 3.89 / 186.52 | 2 | 6 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 31 | 15.17 | 445 | 209 | 0.21 / 178.89 | 2 | 2 |
2 | 7 | 2004.24 | 38 | 14.75 | 2942 | 1649 | 1.86 / 180.54 | 2 | 2 |
3 | 13 | 1279.56 | 18 | 14.90 | 2067 | 554 | 2.41 / 181.09 | 2 | 2 |
4 | 13 | 812.52 | 18 | 15.02 | 1467 | 397 | 2.81 / 181.49 | 2 | 2 |
5 | 13 | 374.64 | 18 | 15.14 | 865 | 236 | 3.04 / 181.73 | 2 | 3 |
6 | 13 | 69.16 | 18 | 15.23 | 415 | 114 | 3.16 / 181.84 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.19 | 316 | 792 | 3.95 / 182.63 | 2 | 6 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 31 | 15.17 | 442 | 208 | 0.21 / 175.13 | 2 | 2 |
2 | 7 | 2002.76 | 38 | 14.76 | 2933 | 1645 | 1.85 / 176.77 | 2 | 2 |
3 | 13 | 1270.60 | 18 | 14.92 | 2053 | 551 | 2.40 / 177.32 | 2 | 2 |
4 | 13 | 774.80 | 18 | 15.04 | 1410 | 382 | 2.79 / 177.71 | 2 | 3 |
5 | 13 | 334.88 | 18 | 15.17 | 806 | 220 | 3.01 / 177.93 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.20 | 301 | 755 | 3.76 / 178.68 | 2 | 7 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 31 | 15.18 | 446 | 210 | 0.21 / 171.15 | 2 | 2 |
2 | 7 | 2012.36 | 38 | 14.75 | 2949 | 1653 | 1.86 / 172.80 | 2 | 2 |
3 | 13 | 1364.92 | 18 | 14.89 | 2180 | 584 | 2.45 / 173.39 | 2 | 2 |
4 | 13 | 841.36 | 18 | 15.02 | 1504 | 407 | 2.85 / 173.80 | 2 | 2 |
5 | 13 | 355.44 | 18 | 15.17 | 835 | 228 | 3.08 / 174.02 | 2 | 2 |
6 | 13 | 102.08 | 18 | 15.22 | 451 | 124 | 3.21 / 174.15 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.20 | 308 | 772 | 3.98 / 174.92 | 2 | 3 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 31 | 15.18 | 442 | 208 | 0.21 / 167.27 | 2 | 2 |
2 | 7 | 2013.56 | 38 | 14.74 | 2958 | 1657 | 1.86 / 168.92 | 2 | 2 |
3 | 13 | 1386.80 | 18 | 14.88 | 2199 | 589 | 2.45 / 169.51 | 2 | 2 |
4 | 13 | 983.72 | 18 | 14.96 | 1684 | 453 | 2.91 / 169.97 | 2 | 3 |
5 | 13 | 330.40 | 18 | 15.17 | 792 | 216 | 3.12 / 170.18 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.21 | 302 | 758 | 3.88 / 170.94 | 2 | 3 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 31 | 15.16 | 451 | 212 | 0.21 / 163.43 | 2 | 2 |
2 | 7 | 2009.48 | 38 | 14.76 | 2948 | 1653 | 1.87 / 165.08 | 2 | 2 |
3 | 13 | 1375.12 | 18 | 14.90 | 2192 | 588 | 2.45 / 165.67 | 2 | 2 |
4 | 13 | 840.12 | 18 | 15.02 | 1498 | 405 | 2.86 / 166.08 | 2 | 3 |
5 | 13 | 349.52 | 18 | 15.17 | 821 | 224 | 3.08 / 166.30 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.22 | 302 | 758 | 3.84 / 167.06 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 31 | 15.18 | 441 | 208 | 0.21 / 159.60 | 2 | 2 |
2 | 7 | 2008.44 | 38 | 14.75 | 2948 | 1652 | 1.86 / 161.25 | 2 | 2 |
3 | 13 | 1294.72 | 18 | 14.92 | 2096 | 563 | 2.42 / 161.81 | 2 | 2 |
4 | 13 | 861.60 | 18 | 15.02 | 1526 | 413 | 2.84 / 162.23 | 2 | 2 |
5 | 13 | 355.28 | 18 | 15.16 | 832 | 227 | 3.06 / 162.45 | 2 | 2 |
6 | 8 | 0.32 | 165 | 15.21 | 305 | 765 | 3.83 / 163.22 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 31 | 15.19 | 443 | 209 | 0.21 / 155.69 | 2 | 2 |
2 | 7 | 2004.12 | 38 | 14.77 | 2948 | 1655 | 1.86 / 157.35 | 2 | 2 |
3 | 13 | 1454.84 | 18 | 14.89 | 2287 | 613 | 2.48 / 157.96 | 2 | 2 |
4 | 13 | 855.08 | 18 | 15.01 | 1525 | 412 | 2.89 / 158.37 | 2 | 3 |
5 | 13 | 391.28 | 18 | 15.16 | 896 | 245 | 3.13 / 158.62 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.21 | 309 | 775 | 3.91 / 159.39 | 2 | 5 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 31 | 15.17 | 443 | 208 | 0.21 / 151.90 | 2 | 2 |
2 | 7 | 2011.28 | 38 | 14.76 | 2933 | 1645 | 1.85 / 153.55 | 2 | 2 |
3 | 13 | 1321.32 | 18 | 14.92 | 2096 | 563 | 2.42 / 154.11 | 2 | 2 |
4 | 13 | 794.04 | 18 | 15.05 | 1439 | 390 | 2.81 / 154.50 | 2 | 3 |
5 | 13 | 310.24 | 18 | 15.18 | 767 | 210 | 3.02 / 154.71 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.22 | 308 | 773 | 3.79 / 155.48 | 2 | 8 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 31 | 15.18 | 473 | 223 | 0.22 / 148.04 | 2 | 2 |
2 | 7 | 2002.92 | 39 | 14.77 | 2940 | 1694 | 1.92 / 149.73 | 2 | 2 |
3 | 13 | 1315.16 | 18 | 14.91 | 2115 | 568 | 2.48 / 150.30 | 2 | 2 |
4 | 13 | 834.60 | 18 | 15.03 | 1489 | 403 | 2.89 / 150.70 | 2 | 3 |
5 | 13 | 336.08 | 18 | 15.17 | 804 | 220 | 3.11 / 150.92 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.22 | 308 | 773 | 3.88 / 151.69 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 31 | 15.20 | 466 | 220 | 0.22 / 144.20 | 2 | 2 |
2 | 7 | 2006.68 | 38 | 14.77 | 2939 | 1650 | 1.87 / 145.85 | 2 | 2 |
3 | 13 | 1296.60 | 18 | 14.93 | 2080 | 559 | 2.43 / 146.41 | 2 | 2 |
4 | 13 | 895.84 | 18 | 15.02 | 1570 | 424 | 2.85 / 146.84 | 2 | 3 |
5 | 13 | 300.40 | 18 | 15.19 | 762 | 208 | 3.06 / 147.05 | 2 | 3 |
6 | 8 | 0.44 | 165 | 15.23 | 306 | 769 | 3.83 / 147.81 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 31 | 15.20 | 466 | 220 | 0.22 / 140.30 | 2 | 2 |
2 | 7 | 2005.60 | 38 | 14.77 | 2916 | 1637 | 1.86 / 141.94 | 2 | 2 |
3 | 13 | 1406.44 | 18 | 14.92 | 2200 | 591 | 2.45 / 142.53 | 2 | 2 |
4 | 13 | 936.24 | 18 | 15.02 | 1622 | 439 | 2.89 / 142.97 | 2 | 3 |
5 | 13 | 371.60 | 18 | 15.18 | 863 | 236 | 3.12 / 143.21 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.23 | 310 | 779 | 3.90 / 143.98 | 2 | 11 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 31 | 15.21 | 465 | 219 | 0.22 / 136.49 | 2 | 2 |
2 | 7 | 2011.84 | 38 | 14.79 | 2928 | 1646 | 1.86 / 138.13 | 2 | 2 |
3 | 13 | 1352.20 | 18 | 14.93 | 2125 | 571 | 2.44 / 138.70 | 2 | 2 |
4 | 13 | 838.36 | 18 | 15.05 | 1495 | 405 | 2.84 / 139.11 | 2 | 2 |
5 | 13 | 296.84 | 18 | 15.20 | 750 | 205 | 3.05 / 139.32 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.23 | 306 | 769 | 3.82 / 140.08 | 2 | 5 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 31 | 15.19 | 461 | 217 | 0.22 / 132.62 | 2 | 2 |
2 | 7 | 2013.68 | 38 | 14.77 | 2958 | 1660 | 1.88 / 134.28 | 2 | 2 |
3 | 13 | 1397.12 | 18 | 14.90 | 2213 | 594 | 2.47 / 134.87 | 2 | 2 |
4 | 13 | 819.76 | 18 | 15.05 | 1472 | 399 | 2.87 / 135.27 | 2 | 2 |
5 | 13 | 319.64 | 18 | 15.19 | 791 | 216 | 3.09 / 135.48 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.23 | 312 | 784 | 3.87 / 136.27 | 2 | 3 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 31 | 15.19 | 460 | 217 | 0.22 / 128.77 | 2 | 2 |
2 | 7 | 2004.60 | 38 | 14.78 | 2949 | 1656 | 1.87 / 130.43 | 2 | 2 |
3 | 13 | 1355.88 | 18 | 14.91 | 2172 | 583 | 2.46 / 131.01 | 2 | 2 |
4 | 13 | 776.08 | 18 | 15.05 | 1422 | 385 | 2.84 / 131.39 | 2 | 3 |
5 | 13 | 336.44 | 18 | 15.18 | 811 | 222 | 3.06 / 131.61 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.23 | 312 | 784 | 3.85 / 132.40 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 31 | 15.20 | 458 | 216 | 0.22 / 124.83 | 2 | 2 |
2 | 7 | 2003.40 | 38 | 14.78 | 2932 | 1647 | 1.86 / 126.48 | 2 | 2 |
3 | 13 | 1294.60 | 18 | 14.95 | 2086 | 561 | 2.42 / 127.04 | 2 | 2 |
4 | 13 | 814.40 | 18 | 15.05 | 1476 | 400 | 2.82 / 127.44 | 2 | 2 |
5 | 13 | 277.52 | 18 | 15.21 | 718 | 197 | 3.02 / 127.64 | 2 | 2 |
6 | 13 | 84.60 | 18 | 15.25 | 439 | 121 | 3.14 / 127.76 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.23 | 316 | 794 | 3.93 / 128.55 | 2 | 7 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 31 | 15.19 | 477 | 225 | 0.22 / 120.99 | 2 | 2 |
2 | 7 | 2005.20 | 38 | 14.79 | 2946 | 1656 | 1.88 / 122.65 | 2 | 2 |
3 | 13 | 1307.44 | 18 | 14.95 | 2103 | 566 | 2.45 / 123.22 | 2 | 2 |
4 | 13 | 839.20 | 18 | 15.05 | 1509 | 409 | 2.86 / 123.62 | 2 | 3 |
5 | 13 | 302.72 | 18 | 15.20 | 760 | 208 | 3.06 / 123.83 | 2 | 2 |
6 | 8 | 0.24 | 165 | 15.24 | 312 | 785 | 3.85 / 124.62 | 2 | 3 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 31 | 15.22 | 459 | 217 | 0.22 / 117.10 | 2 | 2 |
2 | 7 | 2009.24 | 38 | 14.78 | 2918 | 1639 | 1.86 / 118.74 | 2 | 2 |
3 | 13 | 1354.44 | 18 | 14.94 | 2142 | 576 | 2.43 / 119.32 | 2 | 2 |
4 | 13 | 906.60 | 18 | 15.03 | 1578 | 427 | 2.86 / 119.74 | 2 | 3 |
5 | 13 | 391.60 | 18 | 15.18 | 885 | 242 | 3.10 / 119.99 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.24 | 312 | 785 | 3.88 / 120.77 | 2 | 7 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 31 | 15.20 | 459 | 216 | 0.22 / 113.34 | 2 | 2 |
2 | 7 | 2009.92 | 38 | 14.79 | 2926 | 1644 | 1.86 / 114.98 | 2 | 2 |
3 | 13 | 1230.52 | 18 | 14.97 | 1988 | 536 | 2.40 / 115.52 | 2 | 2 |
4 | 13 | 779.60 | 18 | 15.06 | 1417 | 384 | 2.78 / 115.90 | 2 | 3 |
5 | 13 | 293.16 | 18 | 15.22 | 742 | 203 | 2.98 / 116.10 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.24 | 311 | 782 | 3.77 / 116.89 | 2 | 3 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 31 | 15.20 | 472 | 222 | 0.22 / 109.35 | 2 | 2 |
2 | 7 | 2007.16 | 38 | 14.79 | 2953 | 1660 | 1.88 / 111.01 | 2 | 2 |
3 | 13 | 1318.64 | 18 | 14.94 | 2127 | 572 | 2.45 / 111.58 | 2 | 2 |
4 | 13 | 881.16 | 18 | 15.04 | 1567 | 424 | 2.88 / 112.01 | 2 | 2 |
5 | 13 | 332.36 | 18 | 15.20 | 815 | 223 | 3.10 / 112.23 | 2 | 3 |
6 | 13 | 38.40 | 18 | 15.27 | 372 | 102 | 3.20 / 112.33 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.24 | 313 | 787 | 3.99 / 113.12 | 2 | 6 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 31 | 15.21 | 462 | 218 | 0.22 / 105.29 | 2 | 2 |
2 | 7 | 2003.16 | 38 | 14.79 | 2917 | 1639 | 1.86 / 106.93 | 2 | 2 |
3 | 13 | 1455.52 | 18 | 14.93 | 2260 | 607 | 2.46 / 107.53 | 2 | 2 |
4 | 13 | 911.76 | 18 | 15.04 | 1571 | 425 | 2.89 / 107.96 | 2 | 3 |
5 | 13 | 406.00 | 18 | 15.19 | 915 | 250 | 3.14 / 108.21 | 2 | 3 |
6 | 13 | 96.44 | 18 | 15.26 | 457 | 126 | 3.27 / 108.33 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.24 | 316 | 795 | 4.06 / 109.13 | 2 | 4 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 31 | 15.20 | 455 | 214 | 0.21 / 101.28 | 2 | 2 |
2 | 7 | 2004.28 | 38 | 14.81 | 2944 | 1657 | 1.87 / 102.94 | 2 | 2 |
3 | 13 | 1441.04 | 18 | 14.93 | 2278 | 612 | 2.48 / 103.55 | 2 | 2 |
4 | 13 | 889.00 | 18 | 15.06 | 1563 | 424 | 2.91 / 103.97 | 2 | 3 |
5 | 13 | 332.48 | 18 | 15.21 | 801 | 219 | 3.13 / 104.19 | 2 | 3 |
6 | 13 | 18.20 | 18 | 15.29 | 339 | 93 | 3.22 / 104.28 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.24 | 312 | 785 | 4.00 / 105.07 | 2 | 7 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 31 | 15.21 | 451 | 213 | 0.21 / 97.36 | 2 | 2 |
2 | 7 | 2009.32 | 38 | 14.80 | 2921 | 1643 | 1.86 / 99.01 | 2 | 2 |
3 | 13 | 1304.04 | 18 | 14.95 | 2095 | 564 | 2.42 / 99.57 | 2 | 2 |
4 | 13 | 817.72 | 18 | 15.08 | 1473 | 400 | 2.82 / 99.97 | 2 | 3 |
5 | 13 | 324.44 | 18 | 15.22 | 793 | 217 | 3.04 / 100.19 | 2 | 2 |
6 | 13 | 34.36 | 18 | 15.27 | 355 | 98 | 3.13 / 100.28 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.25 | 310 | 780 | 3.91 / 101.06 | 2 | 6 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 31 | 15.22 | 460 | 217 | 0.22 / 93.40 | 2 | 2 |
2 | 7 | 2009.44 | 38 | 14.80 | 2959 | 1664 | 1.88 / 95.07 | 2 | 2 |
3 | 13 | 1336.24 | 18 | 14.95 | 2153 | 579 | 2.46 / 95.65 | 2 | 2 |
4 | 13 | 839.56 | 18 | 15.07 | 1512 | 410 | 2.87 / 96.06 | 2 | 3 |
5 | 13 | 340.36 | 18 | 15.22 | 822 | 225 | 3.10 / 96.28 | 2 | 3 |
6 | 13 | 24.88 | 18 | 15.28 | 343 | 94 | 3.19 / 96.38 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.25 | 307 | 772 | 3.96 / 97.15 | 2 | 5 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 31 | 15.20 | 448 | 211 | 0.21 / 89.45 | 2 | 2 |
2 | 7 | 2015.20 | 38 | 14.81 | 2953 | 1662 | 1.87 / 91.11 | 2 | 2 |
3 | 13 | 1361.64 | 18 | 14.96 | 2184 | 588 | 2.46 / 91.70 | 2 | 2 |
4 | 13 | 800.44 | 18 | 15.09 | 1450 | 394 | 2.85 / 92.09 | 2 | 3 |
5 | 13 | 317.16 | 18 | 15.22 | 781 | 214 | 3.07 / 92.31 | 2 | 3 |
6 | 13 | 33.08 | 18 | 15.29 | 354 | 97 | 3.17 / 92.41 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.25 | 311 | 783 | 3.95 / 93.19 | 2 | 4 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 31 | 15.22 | 456 | 215 | 0.22 / 85.49 | 2 | 2 |
2 | 7 | 2005.84 | 38 | 14.81 | 2949 | 1660 | 1.87 / 87.15 | 2 | 2 |
3 | 13 | 1372.08 | 18 | 14.94 | 2188 | 588 | 2.46 / 87.74 | 2 | 2 |
4 | 13 | 779.52 | 18 | 15.10 | 1419 | 386 | 2.85 / 88.13 | 2 | 3 |
5 | 13 | 329.12 | 18 | 15.22 | 803 | 220 | 3.07 / 88.35 | 2 | 2 |
6 | 13 | 71.36 | 18 | 15.28 | 411 | 113 | 3.18 / 88.46 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.26 | 310 | 781 | 3.96 / 89.24 | 2 | 10 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 31 | 15.23 | 472 | 223 | 0.22 / 81.48 | 2 | 2 |
2 | 7 | 2011.72 | 38 | 14.82 | 2955 | 1664 | 1.89 / 83.15 | 2 | 2 |
3 | 13 | 1391.84 | 18 | 14.96 | 2221 | 598 | 2.49 / 83.75 | 2 | 2 |
4 | 13 | 852.12 | 18 | 15.08 | 1524 | 414 | 2.90 / 84.16 | 2 | 3 |
5 | 13 | 320.20 | 18 | 15.23 | 788 | 216 | 3.11 / 84.38 | 2 | 3 |
6 | 13 | 72.00 | 18 | 15.29 | 419 | 115 | 3.23 / 84.49 | 2 | 2 |
7 | 8 | -0.16 | 165 | 15.26 | 312 | 786 | 4.02 / 85.28 | 2 | 5 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 30 | 15.22 | 450 | 205 | 0.21 / 77.49 | 2 | 2 |
2 | 7 | 2012.72 | 38 | 14.82 | 2965 | 1670 | 1.88 / 79.16 | 2 | 2 |
3 | 13 | 1359.08 | 18 | 14.96 | 2184 | 588 | 2.46 / 79.75 | 2 | 2 |
4 | 13 | 832.24 | 18 | 15.08 | 1503 | 408 | 2.87 / 80.16 | 2 | 3 |
5 | 13 | 308.56 | 18 | 15.23 | 769 | 211 | 3.08 / 80.37 | 2 | 2 |
6 | 13 | 67.68 | 18 | 15.28 | 410 | 113 | 3.19 / 80.48 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.25 | 309 | 778 | 3.97 / 81.26 | 2 | 4 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 30 | 15.22 | 450 | 205 | 0.21 / 73.53 | 2 | 2 |
2 | 7 | 2003.72 | 39 | 14.83 | 2921 | 1689 | 1.89 / 75.22 | 2 | 2 |
3 | 13 | 1319.76 | 18 | 14.98 | 2111 | 569 | 2.46 / 75.79 | 2 | 2 |
4 | 13 | 825.64 | 18 | 15.09 | 1491 | 405 | 2.87 / 76.20 | 2 | 3 |
5 | 13 | 293.20 | 18 | 15.25 | 746 | 205 | 3.07 / 76.40 | 2 | 3 |
6 | 13 | 52.28 | 18 | 15.29 | 387 | 107 | 3.18 / 76.51 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.26 | 310 | 781 | 3.96 / 77.29 | 2 | 10 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 30 | 15.22 | 449 | 205 | 0.21 / 69.60 | 2 | 2 |
2 | 7 | 2007.28 | 38 | 14.83 | 2952 | 1664 | 1.87 / 71.27 | 2 | 2 |
3 | 13 | 1271.84 | 18 | 15.00 | 2059 | 556 | 2.42 / 71.82 | 2 | 2 |
4 | 13 | 755.64 | 18 | 15.12 | 1396 | 380 | 2.80 / 72.20 | 2 | 3 |
5 | 13 | 345.96 | 18 | 15.24 | 828 | 227 | 3.03 / 72.43 | 2 | 3 |
6 | 13 | 39.80 | 18 | 15.30 | 370 | 102 | 3.13 / 72.53 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.27 | 316 | 796 | 3.93 / 73.33 | 2 | 14 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 30 | 15.22 | 456 | 208 | 0.21 / 65.55 | 2 | 2 |
2 | 7 | 2004.76 | 38 | 14.82 | 2947 | 1660 | 1.87 / 67.21 | 2 | 2 |
3 | 13 | 1399.88 | 18 | 14.97 | 2235 | 602 | 2.47 / 67.81 | 2 | 2 |
4 | 13 | 984.48 | 18 | 15.05 | 1695 | 459 | 2.93 / 68.27 | 2 | 3 |
5 | 13 | 356.88 | 18 | 15.23 | 844 | 231 | 3.16 / 68.50 | 2 | 3 |
6 | 13 | 60.40 | 18 | 15.30 | 408 | 112 | 3.27 / 68.61 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.27 | 312 | 786 | 4.06 / 69.40 | 2 | 3 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 30 | 15.24 | 450 | 206 | 0.21 / 61.63 | 2 | 2 |
2 | 7 | 2004.48 | 38 | 14.83 | 2944 | 1659 | 1.86 / 63.29 | 2 | 2 |
3 | 13 | 1321.12 | 18 | 14.99 | 2134 | 576 | 2.44 / 63.87 | 2 | 2 |
4 | 13 | 781.92 | 18 | 15.11 | 1426 | 388 | 2.83 / 64.25 | 2 | 3 |
5 | 13 | 295.00 | 18 | 15.26 | 741 | 204 | 3.03 / 64.46 | 2 | 2 |
6 | 13 | 28.68 | 18 | 15.31 | 355 | 98 | 3.13 / 64.55 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.27 | 311 | 784 | 3.91 / 65.34 | 2 | 5 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 30 | 15.24 | 451 | 206 | 0.21 / 57.69 | 2 | 2 |
2 | 7 | 2012.20 | 38 | 14.84 | 2953 | 1665 | 1.87 / 59.35 | 2 | 2 |
3 | 13 | 1315.04 | 18 | 15.00 | 2130 | 575 | 2.45 / 59.93 | 2 | 2 |
4 | 13 | 834.12 | 18 | 15.11 | 1500 | 408 | 2.85 / 60.34 | 2 | 3 |
5 | 13 | 286.84 | 18 | 15.27 | 736 | 202 | 3.06 / 60.54 | 2 | 2 |
6 | 13 | 54.68 | 18 | 15.32 | 384 | 106 | 3.16 / 60.65 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.28 | 309 | 779 | 3.94 / 61.43 | 2 | 5 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 30 | 15.24 | 440 | 201 | 0.20 / 53.76 | 2 | 2 |
2 | 7 | 2009.84 | 38 | 14.85 | 2938 | 1658 | 1.86 / 55.42 | 2 | 2 |
3 | 13 | 1312.00 | 18 | 15.01 | 2112 | 571 | 2.43 / 55.99 | 2 | 2 |
4 | 13 | 794.16 | 18 | 15.12 | 1434 | 390 | 2.82 / 56.38 | 2 | 3 |
5 | 13 | 304.92 | 18 | 15.26 | 768 | 211 | 3.03 / 56.59 | 2 | 3 |
6 | 13 | 57.84 | 18 | 15.31 | 394 | 109 | 3.14 / 56.70 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.28 | 310 | 782 | 3.92 / 57.48 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 30 | 15.23 | 448 | 205 | 0.20 / 49.88 | 2 | 2 |
2 | 7 | 2005.60 | 38 | 14.85 | 2945 | 1662 | 1.87 / 51.54 | 2 | 2 |
3 | 13 | 1250.96 | 18 | 15.02 | 2032 | 549 | 2.42 / 52.09 | 2 | 2 |
4 | 13 | 858.24 | 18 | 15.10 | 1512 | 411 | 2.83 / 52.50 | 2 | 3 |
5 | 13 | 267.44 | 18 | 15.27 | 695 | 191 | 3.02 / 52.69 | 2 | 3 |
6 | 13 | 37.72 | 18 | 15.32 | 354 | 98 | 3.12 / 52.79 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.28 | 307 | 774 | 3.89 / 53.56 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 30 | 15.24 | 440 | 201 | 0.20 / 45.89 | 2 | 2 |
2 | 7 | 2003.72 | 39 | 14.84 | 2912 | 1685 | 1.89 / 47.57 | 2 | 2 |
3 | 13 | 1311.28 | 18 | 15.00 | 2108 | 569 | 2.46 / 48.14 | 2 | 2 |
4 | 13 | 818.44 | 18 | 15.11 | 1472 | 400 | 2.86 / 48.54 | 2 | 3 |
5 | 13 | 370.96 | 18 | 15.24 | 857 | 235 | 3.09 / 48.78 | 2 | 3 |
6 | 13 | 52.72 | 18 | 15.32 | 381 | 105 | 3.20 / 48.88 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.28 | 314 | 792 | 3.99 / 49.67 | 2 | 10 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 30 | 15.25 | 451 | 206 | 0.21 / 41.95 | 2 | 2 |
2 | 7 | 2005.36 | 39 | 14.85 | 2927 | 1695 | 1.90 / 43.65 | 2 | 2 |
3 | 13 | 1272.40 | 18 | 15.02 | 2049 | 554 | 2.46 / 44.20 | 2 | 2 |
4 | 13 | 789.72 | 18 | 15.13 | 1421 | 387 | 2.84 / 44.59 | 2 | 2 |
5 | 13 | 334.12 | 18 | 15.25 | 802 | 220 | 3.06 / 44.81 | 2 | 2 |
6 | 13 | 43.20 | 18 | 15.31 | 367 | 101 | 3.16 / 44.91 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.28 | 308 | 777 | 3.94 / 45.68 | 2 | 8 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 30 | 15.25 | 449 | 205 | 0.21 / 38.03 | 2 | 2 |
2 | 7 | 2006.88 | 39 | 14.86 | 2928 | 1697 | 1.90 / 39.73 | 2 | 2 |
3 | 13 | 1339.36 | 18 | 15.01 | 2112 | 571 | 2.47 / 40.30 | 2 | 2 |
4 | 13 | 768.88 | 18 | 15.14 | 1392 | 379 | 2.85 / 40.68 | 2 | 2 |
5 | 13 | 298.76 | 18 | 15.27 | 731 | 201 | 3.05 / 40.88 | 2 | 2 |
6 | 13 | 31.12 | 18 | 15.33 | 345 | 95 | 3.15 / 40.98 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.29 | 304 | 767 | 3.92 / 41.74 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 30 | 15.27 | 438 | 201 | 0.20 / 33.46 | 2 | 2 |
2 | 7 | 2004.32 | 74 | 14.74 | 2914 | 3178 | 3.38 / 36.63 | 2 | 2 |
3 | 13 | 537.64 | 18 | 15.21 | 1074 | 294 | 3.67 / 36.93 | 2 | 3 |
4 | 13 | 130.00 | 18 | 15.31 | 483 | 133 | 3.81 / 37.06 | 2 | 2 |
5 | 8 | 0.16 | 165 | 15.30 | 304 | 767 | 4.57 / 37.83 | 2 | 9 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 30 | 15.27 | 429 | 197 | 0.20 / 28.91 | 2 | 2 |
2 | 7 | 2007.52 | 74 | 14.76 | 2921 | 3190 | 3.39 / 32.10 | 2 | 2 |
3 | 13 | 492.36 | 18 | 15.23 | 1018 | 279 | 3.67 / 32.38 | 2 | 3 |
4 | 13 | 103.52 | 18 | 15.33 | 443 | 122 | 3.79 / 32.50 | 2 | 2 |
5 | 8 | 0.24 | 165 | 15.31 | 300 | 758 | 4.55 / 33.26 | 2 | 5 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 29 | 15.26 | 404 | 179 | 0.18 / 24.45 | 2 | 2 |
2 | 7 | 2015.68 | 74 | 14.75 | 2922 | 3189 | 3.37 / 27.64 | 2 | 2 |
3 | 13 | 413.52 | 18 | 15.26 | 888 | 244 | 3.61 / 27.88 | 2 | 2 |
4 | 13 | 137.04 | 18 | 15.32 | 475 | 131 | 3.74 / 28.01 | 2 | 2 |
5 | 8 | 0.44 | 165 | 15.31 | 275 | 695 | 4.44 / 28.71 | 2 | 3 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 28 | 15.28 | 412 | 176 | 0.18 / 20.02 | 2 | 2 |
2 | 3 | 1034.24 | 1 | 15.30 | 1775 | 27 | 0.20 / 20.05 | 2 | 2 |
3 | 7 | 2008.28 | 74 | 14.76 | 2909 | 3177 | 3.38 / 23.22 | 2 | 2 |
4 | 13 | 432.24 | 18 | 15.25 | 918 | 252 | 3.63 / 23.48 | 2 | 3 |
5 | 13 | 79.84 | 18 | 15.33 | 387 | 107 | 3.74 / 23.58 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.31 | 273 | 690 | 4.43 / 24.27 | 2 | 4 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 29 | 15.29 | 432 | 192 | 0.19 / 15.60 | 2 | 2 |
2 | 7 | 2003.52 | 74 | 14.76 | 2900 | 3167 | 3.36 / 18.76 | 2 | 2 |
3 | 13 | 497.68 | 18 | 15.22 | 1005 | 275 | 3.63 / 19.04 | 2 | 3 |
4 | 13 | 97.56 | 18 | 15.33 | 418 | 115 | 3.75 / 19.15 | 2 | 2 |
5 | 8 | 0.08 | 165 | 15.30 | 273 | 689 | 4.44 / 19.84 | 2 | 4 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 29 | 15.28 | 412 | 183 | 0.18 / 12.00 | 2 | 2 |
2 | 7 | 1509.00 | 74 | 14.96 | 2288 | 2533 | 2.72 / 14.53 | 2 | 2 |
3 | 13 | 280.28 | 18 | 15.30 | 693 | 191 | 2.91 / 14.72 | 2 | 2 |
4 | 8 | 0.04 | 165 | 15.32 | 270 | 683 | 3.59 / 15.40 | 2 | 5 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.56 | 29 | 15.26 | 434 | 192 | 0.19 / 8.29 | 2 | 2 |
2 | 7 | 1520.44 | 74 | 14.96 | 2304 | 2551 | 2.74 / 10.84 | 2 | 2 |
3 | 13 | 310.72 | 18 | 15.29 | 735 | 202 | 2.94 / 11.04 | 2 | 2 |
4 | 13 | 17.96 | 18 | 15.35 | 301 | 83 | 3.03 / 11.13 | 2 | 2 |
5 | 8 | -0.04 | 165 | 15.31 | 273 | 690 | 3.72 / 11.81 | 2 | 8 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 31 | 15.31 | 414 | 196 | 0.20 / 4.54 | 2 | 2 |
2 | 3 | 881.60 | -2 | 15.69 | 0 | 0 | 0.00 / 4.54 | 2 | 2 |
3 | 7 | 1524.76 | 74 | 14.96 | 2316 | 2564 | 2.76 / 7.11 | 2 | 2 |
4 | 13 | 315.88 | 18 | 15.30 | 745 | 205 | 2.97 / 7.31 | 2 | 2 |
5 | 13 | 36.52 | 18 | 15.35 | 328 | 91 | 3.06 / 7.40 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.32 | 274 | 693 | 3.75 / 8.10 | 2 | 8 |
Average= | 2.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 26 | 15.47 | 400 | 161 | 0.16 / 1.77 | 2 | 3 |
2 | 3 | 1037.92 | 1 | 15.33 | 1795 | 28 | 0.19 / 1.80 | 2 | 2 |
3 | 7 | 1001.32 | 74 | 15.14 | 1641 | 1839 | 2.03 / 3.63 | 2 | 3 |
4 | 8 | 0.00 | 165 | 15.36 | 282 | 715 | 2.74 / 4.35 | 2 | 8 |
Average= | 2.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 171.36 | 26 | 15.60 | 469 | 190 | 0.19 / 0.19 | 3 | 3 |
2 | 7 | 186.80 | 75 | 15.57 | 482 | 563 | 0.75 / 0.75 | 3 | 3 |
3 | 8 | 0.36 | 240 | 15.53 | 229 | 854 | 1.61 / 1.61 | 3 | 6 |
Average= | 1.61 (KJ/cycle) |