SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 24 | 15.01 | 457 | 165 | 0.16 / 434.61 | 3 | 19 |
2 | 7 | 1872.76 | 33 | 14.80 | 2841 | 1388 | 1.55 / 436.00 | 2 | 6 |
3 | 13 | 1291.16 | 20 | 14.86 | 2103 | 625 | 2.18 / 436.62 | 2 | 3 |
4 | 13 | 895.16 | 20 | 14.91 | 1583 | 472 | 2.65 / 437.09 | 2 | 4 |
5 | 13 | 354.04 | 20 | 15.04 | 850 | 256 | 2.90 / 437.35 | 2 | 6 |
6 | 13 | 137.80 | 20 | 15.07 | 517 | 156 | 3.06 / 437.50 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.05 | 310 | 770 | 3.83 / 438.27 | 2 | 5 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 24 | 15.00 | 461 | 166 | 0.17 / 430.86 | 3 | 14 |
2 | 7 | 1873.92 | 33 | 14.77 | 2837 | 1383 | 1.55 / 432.24 | 2 | 8 |
3 | 13 | 1354.92 | 20 | 14.84 | 2187 | 649 | 2.20 / 432.89 | 2 | 7 |
4 | 13 | 730.36 | 20 | 14.98 | 1365 | 409 | 2.61 / 433.30 | 2 | 4 |
5 | 13 | 270.68 | 20 | 15.08 | 737 | 222 | 2.83 / 433.53 | 2 | 3 |
6 | 13 | 124.00 | 20 | 15.10 | 508 | 153 | 2.98 / 433.68 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.06 | 308 | 765 | 3.75 / 434.44 | 2 | 78 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 24 | 15.02 | 451 | 163 | 0.16 / 427.05 | 3 | 3 |
2 | 7 | 1875.28 | 34 | 14.76 | 2858 | 1434 | 1.60 / 428.48 | 2 | 4 |
3 | 13 | 1367.12 | 20 | 14.83 | 2204 | 654 | 2.25 / 429.14 | 2 | 9 |
4 | 13 | 793.00 | 20 | 14.93 | 1463 | 437 | 2.69 / 429.57 | 2 | 11 |
5 | 13 | 262.88 | 20 | 15.08 | 726 | 219 | 2.91 / 429.79 | 2 | 7 |
6 | 13 | 121.92 | 20 | 15.09 | 505 | 152 | 3.06 / 429.95 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.05 | 302 | 750 | 3.81 / 430.70 | 2 | 2 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 24 | 15.01 | 451 | 162 | 0.16 / 423.55 | 3 | 3 |
2 | 7 | 1480.80 | 34 | 14.92 | 2324 | 1179 | 1.34 / 424.73 | 2 | 14 |
3 | 13 | 1349.04 | 20 | 14.91 | 2160 | 644 | 1.99 / 425.38 | 2 | 3 |
4 | 13 | 611.04 | 20 | 15.04 | 1200 | 361 | 2.35 / 425.74 | 2 | 5 |
5 | 13 | 288.20 | 20 | 15.11 | 750 | 227 | 2.57 / 425.96 | 2 | 3 |
6 | 13 | 139.92 | 20 | 15.10 | 520 | 157 | 2.73 / 426.12 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.07 | 308 | 766 | 3.50 / 426.89 | 2 | 2 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 24 | 14.99 | 467 | 168 | 0.17 / 419.71 | 3 | 3 |
2 | 7 | 1875.76 | 33 | 14.79 | 2861 | 1396 | 1.56 / 421.10 | 2 | 10 |
3 | 13 | 1423.76 | 20 | 14.83 | 2273 | 674 | 2.24 / 421.78 | 2 | 8 |
4 | 13 | 779.84 | 20 | 14.96 | 1445 | 432 | 2.67 / 422.21 | 2 | 3 |
5 | 13 | 351.92 | 20 | 15.04 | 861 | 259 | 2.93 / 422.47 | 2 | 9 |
6 | 13 | 137.52 | 20 | 15.09 | 532 | 161 | 3.09 / 422.63 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.06 | 307 | 763 | 3.85 / 423.39 | 2 | 95 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 24 | 15.00 | 464 | 167 | 0.17 / 415.80 | 3 | 6 |
2 | 7 | 1882.64 | 33 | 14.76 | 2852 | 1389 | 1.56 / 417.19 | 2 | 6 |
3 | 13 | 1408.72 | 20 | 14.83 | 2265 | 672 | 2.23 / 417.86 | 2 | 8 |
4 | 13 | 695.56 | 20 | 14.98 | 1324 | 397 | 2.62 / 418.26 | 2 | 7 |
5 | 13 | 337.80 | 20 | 15.04 | 838 | 252 | 2.88 / 418.51 | 2 | 6 |
6 | 13 | 131.16 | 20 | 15.07 | 518 | 156 | 3.03 / 418.66 | 2 | 11 |
7 | 13 | 38.48 | 20 | 15.08 | 371 | 112 | 3.14 / 418.78 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.04 | 307 | 762 | 3.91 / 419.54 | 2 | 72 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 25 | 15.00 | 459 | 172 | 0.17 / 411.79 | 3 | 13 |
2 | 7 | 1872.64 | 34 | 14.78 | 2851 | 1433 | 1.60 / 413.22 | 2 | 7 |
3 | 13 | 1450.64 | 20 | 14.83 | 2303 | 683 | 2.29 / 413.90 | 2 | 8 |
4 | 13 | 906.20 | 20 | 14.92 | 1604 | 479 | 2.77 / 414.38 | 2 | 6 |
5 | 13 | 311.88 | 20 | 15.08 | 791 | 239 | 3.01 / 414.62 | 2 | 4 |
6 | 13 | 118.04 | 20 | 15.09 | 494 | 149 | 3.15 / 414.77 | 2 | 20 |
7 | 13 | 39.24 | 20 | 15.08 | 363 | 109 | 3.26 / 414.88 | 2 | 50 |
8 | 8 | 0.12 | 165 | 15.04 | 303 | 752 | 4.02 / 415.63 | 2 | 48 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 25 | 14.99 | 465 | 174 | 0.17 / 407.79 | 3 | 9 |
2 | 7 | 1875.48 | 33 | 14.78 | 2852 | 1391 | 1.57 / 409.18 | 2 | 3 |
3 | 13 | 1464.20 | 20 | 14.82 | 2330 | 691 | 2.26 / 409.87 | 2 | 8 |
4 | 13 | 826.16 | 20 | 14.94 | 1492 | 446 | 2.70 / 410.32 | 2 | 2 |
5 | 13 | 385.16 | 20 | 15.04 | 907 | 273 | 2.97 / 410.59 | 2 | 4 |
6 | 13 | 123.08 | 20 | 15.09 | 507 | 153 | 3.13 / 410.74 | 2 | 14 |
7 | 13 | 40.52 | 20 | 15.08 | 373 | 112 | 3.24 / 410.85 | 2 | 30 |
8 | 8 | 0.04 | 165 | 15.05 | 307 | 762 | 4.00 / 411.62 | 2 | 19 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 25 | 14.99 | 455 | 171 | 0.17 / 403.81 | 3 | 15 |
2 | 7 | 1874.56 | 33 | 14.79 | 2835 | 1384 | 1.55 / 405.19 | 2 | 6 |
3 | 13 | 1429.24 | 20 | 14.83 | 2277 | 675 | 2.23 / 405.87 | 2 | 5 |
4 | 13 | 744.12 | 20 | 14.96 | 1390 | 416 | 2.65 / 406.28 | 2 | 4 |
5 | 13 | 423.12 | 20 | 15.03 | 956 | 287 | 2.93 / 406.57 | 2 | 3 |
6 | 13 | 144.20 | 20 | 15.09 | 543 | 164 | 3.10 / 406.73 | 2 | 4 |
7 | 13 | 44.84 | 20 | 15.08 | 384 | 116 | 3.21 / 406.85 | 2 | 7 |
8 | 8 | 0.00 | 165 | 15.03 | 308 | 764 | 3.98 / 407.61 | 3 | 72 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 25 | 14.98 | 454 | 170 | 0.17 / 399.86 | 3 | 11 |
2 | 7 | 1872.28 | 33 | 14.79 | 2823 | 1378 | 1.55 / 401.24 | 2 | 2 |
3 | 13 | 1368.84 | 20 | 14.84 | 2201 | 653 | 2.20 / 401.89 | 2 | 3 |
4 | 13 | 846.20 | 20 | 14.92 | 1525 | 455 | 2.66 / 402.35 | 2 | 7 |
5 | 13 | 345.32 | 20 | 15.05 | 848 | 255 | 2.91 / 402.60 | 2 | 4 |
6 | 13 | 134.52 | 20 | 15.09 | 526 | 159 | 3.07 / 402.76 | 2 | 12 |
7 | 13 | 42.84 | 20 | 15.08 | 379 | 114 | 3.18 / 402.88 | 2 | 25 |
8 | 8 | 0.12 | 165 | 15.04 | 307 | 762 | 3.95 / 403.64 | 2 | 19 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 25 | 15.01 | 467 | 175 | 0.18 / 395.82 | 3 | 3 |
2 | 7 | 1873.56 | 33 | 14.77 | 2855 | 1392 | 1.57 / 397.21 | 2 | 12 |
3 | 13 | 1332.44 | 20 | 14.83 | 2159 | 640 | 2.21 / 397.85 | 2 | 9 |
4 | 13 | 720.92 | 20 | 14.97 | 1361 | 407 | 2.61 / 398.25 | 2 | 5 |
5 | 13 | 353.64 | 20 | 15.05 | 856 | 258 | 2.87 / 398.51 | 2 | 5 |
6 | 13 | 135.08 | 20 | 15.08 | 528 | 159 | 3.03 / 398.67 | 2 | 8 |
7 | 13 | 41.68 | 20 | 15.07 | 381 | 115 | 3.15 / 398.79 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.04 | 309 | 767 | 3.91 / 399.55 | 2 | 34 |
9 | 14 | 0.04 | 30 | 15.00 | 305 | 137 | 4.05 / 399.69 | 3 | 77 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 25 | 15.00 | 458 | 172 | 0.17 / 391.86 | 3 | 19 |
2 | 7 | 1879.76 | 33 | 14.81 | 2854 | 1395 | 1.57 / 393.26 | 2 | 7 |
3 | 13 | 1399.12 | 20 | 14.86 | 2251 | 669 | 2.24 / 393.93 | 2 | 3 |
4 | 13 | 852.36 | 20 | 14.93 | 1532 | 457 | 2.69 / 394.38 | 2 | 5 |
5 | 13 | 324.76 | 20 | 15.06 | 813 | 245 | 2.94 / 394.63 | 2 | 3 |
6 | 13 | 127.12 | 20 | 15.09 | 505 | 152 | 3.09 / 394.78 | 2 | 37 |
7 | 13 | 19.44 | 20 | 15.09 | 338 | 102 | 3.19 / 394.88 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.06 | 305 | 758 | 3.95 / 395.64 | 2 | 22 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 25 | 15.00 | 465 | 174 | 0.17 / 387.82 | 3 | 10 |
2 | 7 | 1872.88 | 33 | 14.79 | 2853 | 1392 | 1.57 / 389.21 | 2 | 6 |
3 | 13 | 1492.00 | 20 | 14.81 | 2367 | 701 | 2.27 / 389.91 | 2 | 8 |
4 | 13 | 902.80 | 20 | 14.91 | 1603 | 478 | 2.75 / 390.39 | 2 | 7 |
5 | 13 | 355.60 | 20 | 15.05 | 857 | 258 | 3.00 / 390.65 | 2 | 3 |
6 | 13 | 152.28 | 20 | 15.08 | 556 | 168 | 3.17 / 390.82 | 2 | 13 |
7 | 13 | 32.84 | 20 | 15.08 | 363 | 109 | 3.28 / 390.93 | 2 | 12 |
8 | 8 | 0.00 | 165 | 15.04 | 308 | 764 | 4.05 / 391.69 | 2 | 58 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 25 | 15.01 | 450 | 169 | 0.17 / 383.85 | 3 | 10 |
2 | 7 | 1872.24 | 34 | 14.79 | 2845 | 1431 | 1.60 / 385.28 | 2 | 8 |
3 | 13 | 1431.32 | 20 | 14.83 | 2274 | 674 | 2.27 / 385.95 | 2 | 8 |
4 | 13 | 806.00 | 20 | 14.96 | 1478 | 442 | 2.72 / 386.39 | 2 | 9 |
5 | 13 | 292.28 | 20 | 15.08 | 766 | 231 | 2.95 / 386.63 | 2 | 3 |
6 | 13 | 143.00 | 20 | 15.08 | 534 | 161 | 3.11 / 386.79 | 2 | 36 |
7 | 13 | 22.72 | 20 | 15.09 | 343 | 104 | 3.21 / 386.89 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.05 | 304 | 755 | 3.97 / 387.64 | 2 | 63 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 25 | 15.00 | 443 | 166 | 0.17 / 379.90 | 3 | 10 |
2 | 7 | 1870.96 | 33 | 14.81 | 2845 | 1390 | 1.56 / 381.29 | 2 | 6 |
3 | 13 | 1440.20 | 20 | 14.84 | 2299 | 682 | 2.24 / 381.97 | 2 | 11 |
4 | 13 | 770.12 | 20 | 14.96 | 1433 | 429 | 2.67 / 382.40 | 2 | 6 |
5 | 13 | 338.92 | 20 | 15.06 | 837 | 252 | 2.92 / 382.65 | 2 | 5 |
6 | 13 | 139.72 | 20 | 15.09 | 529 | 160 | 3.08 / 382.81 | 2 | 5 |
7 | 13 | 22.28 | 20 | 15.08 | 344 | 104 | 3.18 / 382.92 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.04 | 307 | 762 | 3.95 / 383.68 | 2 | 63 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 24 | 14.98 | 466 | 168 | 0.17 / 375.92 | 3 | 3 |
2 | 3 | 1017.32 | 1 | 15.13 | 1804 | 27 | 0.19 / 375.95 | 2 | 26 |
3 | 7 | 1873.20 | 33 | 14.81 | 2844 | 1390 | 1.58 / 377.34 | 2 | 23 |
4 | 13 | 1360.60 | 20 | 14.86 | 2191 | 651 | 2.24 / 377.99 | 2 | 11 |
5 | 13 | 829.76 | 20 | 14.95 | 1511 | 452 | 2.69 / 378.44 | 2 | 8 |
6 | 13 | 292.08 | 20 | 15.07 | 773 | 233 | 2.92 / 378.67 | 2 | 16 |
7 | 13 | 193.32 | 20 | 15.07 | 615 | 185 | 3.11 / 378.86 | 2 | 5 |
8 | 13 | 48.36 | 20 | 15.09 | 386 | 116 | 3.22 / 378.98 | 2 | 2 |
9 | 8 | 0.04 | 165 | 15.05 | 305 | 757 | 3.98 / 379.73 | 2 | 9 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 24 | 15.00 | 455 | 164 | 0.16 / 371.99 | 3 | 3 |
2 | 7 | 1872.08 | 33 | 14.80 | 2837 | 1386 | 1.55 / 373.38 | 2 | 25 |
3 | 13 | 1293.16 | 20 | 14.86 | 2114 | 628 | 2.18 / 374.00 | 2 | 10 |
4 | 13 | 795.36 | 20 | 14.94 | 1472 | 440 | 2.62 / 374.44 | 2 | 7 |
5 | 13 | 362.28 | 20 | 15.04 | 880 | 265 | 2.88 / 374.71 | 2 | 3 |
6 | 13 | 149.16 | 20 | 15.08 | 554 | 167 | 3.05 / 374.88 | 2 | 3 |
7 | 13 | 28.72 | 20 | 15.08 | 356 | 107 | 3.16 / 374.98 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.04 | 310 | 769 | 3.93 / 375.75 | 2 | 96 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 24 | 15.00 | 460 | 166 | 0.17 / 368.00 | 3 | 10 |
2 | 7 | 1877.16 | 33 | 14.80 | 2856 | 1395 | 1.56 / 369.39 | 2 | 26 |
3 | 13 | 1441.16 | 20 | 14.84 | 2290 | 680 | 2.24 / 370.07 | 2 | 5 |
4 | 13 | 790.24 | 20 | 14.97 | 1455 | 436 | 2.68 / 370.51 | 2 | 14 |
5 | 13 | 403.32 | 20 | 15.05 | 933 | 281 | 2.96 / 370.79 | 2 | 11 |
6 | 13 | 132.72 | 20 | 15.09 | 532 | 161 | 3.12 / 370.95 | 2 | 28 |
7 | 13 | 21.64 | 20 | 15.10 | 352 | 106 | 3.22 / 371.05 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.05 | 311 | 772 | 4.00 / 371.83 | 2 | 50 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 24 | 14.99 | 456 | 164 | 0.16 / 364.19 | 3 | 3 |
2 | 7 | 1878.80 | 34 | 14.78 | 2835 | 1425 | 1.59 / 365.61 | 2 | 5 |
3 | 13 | 1327.04 | 20 | 14.85 | 2136 | 634 | 2.22 / 366.25 | 2 | 3 |
4 | 13 | 757.48 | 20 | 14.96 | 1402 | 419 | 2.64 / 366.67 | 2 | 8 |
5 | 13 | 284.88 | 20 | 15.07 | 764 | 230 | 2.87 / 366.90 | 2 | 6 |
6 | 13 | 146.92 | 20 | 15.08 | 547 | 165 | 3.04 / 367.06 | 2 | 45 |
7 | 8 | 0.12 | 165 | 15.04 | 310 | 769 | 3.81 / 367.83 | 2 | 2 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 24 | 15.02 | 465 | 168 | 0.17 / 360.23 | 3 | 3 |
2 | 7 | 1875.92 | 33 | 14.80 | 2836 | 1385 | 1.55 / 361.62 | 2 | 20 |
3 | 13 | 1367.20 | 20 | 14.85 | 2197 | 653 | 2.21 / 362.27 | 2 | 13 |
4 | 13 | 850.28 | 20 | 14.93 | 1527 | 456 | 2.66 / 362.73 | 2 | 3 |
5 | 13 | 358.76 | 20 | 15.07 | 867 | 261 | 2.92 / 362.99 | 2 | 10 |
6 | 13 | 154.00 | 20 | 15.08 | 542 | 163 | 3.09 / 363.15 | 2 | 2 |
7 | 13 | 28.88 | 20 | 15.08 | 356 | 107 | 3.19 / 363.26 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.04 | 309 | 767 | 3.96 / 364.02 | 2 | 15 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 25 | 15.00 | 466 | 175 | 0.17 / 356.40 | 3 | 3 |
2 | 7 | 1872.64 | 33 | 14.79 | 2848 | 1390 | 1.56 / 357.79 | 2 | 5 |
3 | 13 | 1409.44 | 20 | 14.85 | 2264 | 672 | 2.24 / 358.46 | 2 | 16 |
4 | 13 | 787.24 | 20 | 14.95 | 1448 | 433 | 2.67 / 358.89 | 2 | 4 |
5 | 13 | 308.68 | 20 | 15.06 | 805 | 242 | 2.91 / 359.13 | 2 | 17 |
6 | 13 | 165.04 | 20 | 15.08 | 576 | 174 | 3.09 / 359.31 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.05 | 305 | 757 | 3.84 / 360.06 | 2 | 18 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 25 | 15.02 | 470 | 176 | 0.18 / 352.46 | 3 | 14 |
2 | 7 | 1875.44 | 33 | 14.79 | 2842 | 1387 | 1.56 / 353.85 | 2 | 15 |
3 | 13 | 1387.84 | 20 | 14.84 | 2235 | 663 | 2.23 / 354.51 | 2 | 7 |
4 | 13 | 768.12 | 20 | 14.96 | 1430 | 428 | 2.65 / 354.94 | 2 | 11 |
5 | 13 | 299.28 | 20 | 15.07 | 783 | 236 | 2.89 / 355.18 | 2 | 9 |
6 | 13 | 160.96 | 20 | 15.07 | 564 | 170 | 3.06 / 355.35 | 2 | 13 |
7 | 13 | 32.16 | 20 | 15.09 | 357 | 108 | 3.17 / 355.46 | 2 | 20 |
8 | 8 | 0.20 | 165 | 15.05 | 308 | 765 | 3.93 / 356.22 | 2 | 66 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 25 | 15.00 | 456 | 171 | 0.17 / 348.46 | 3 | 3 |
2 | 7 | 1884.60 | 33 | 14.80 | 2843 | 1389 | 1.56 / 349.85 | 2 | 4 |
3 | 13 | 1493.80 | 20 | 14.82 | 2359 | 699 | 2.26 / 350.55 | 2 | 3 |
4 | 13 | 745.04 | 20 | 14.97 | 1396 | 418 | 2.68 / 350.97 | 2 | 8 |
5 | 13 | 376.32 | 20 | 15.06 | 895 | 270 | 2.95 / 351.24 | 2 | 3 |
6 | 13 | 161.72 | 20 | 15.09 | 568 | 171 | 3.12 / 351.41 | 2 | 43 |
7 | 13 | 28.40 | 20 | 15.09 | 363 | 110 | 3.23 / 351.52 | 2 | 35 |
8 | 8 | 0.00 | 165 | 15.05 | 310 | 770 | 4.00 / 352.29 | 2 | 69 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 25 | 15.02 | 463 | 174 | 0.17 / 344.48 | 3 | 13 |
2 | 7 | 1872.80 | 33 | 14.80 | 2828 | 1381 | 1.56 / 345.86 | 2 | 9 |
3 | 13 | 1417.60 | 20 | 14.85 | 2276 | 676 | 2.23 / 346.53 | 2 | 11 |
4 | 13 | 831.92 | 20 | 14.94 | 1500 | 448 | 2.68 / 346.98 | 2 | 7 |
5 | 13 | 397.24 | 20 | 15.05 | 926 | 279 | 2.96 / 347.26 | 2 | 3 |
6 | 13 | 128.68 | 20 | 15.10 | 516 | 156 | 3.11 / 347.41 | 2 | 22 |
7 | 13 | 17.96 | 20 | 15.10 | 340 | 103 | 3.22 / 347.52 | 2 | 21 |
8 | 8 | -0.04 | 165 | 15.05 | 311 | 772 | 3.99 / 348.29 | 2 | 100 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 24 | 15.01 | 467 | 168 | 0.17 / 340.58 | 3 | 4 |
2 | 3 | 1020.00 | 1 | 15.17 | 1818 | 28 | 0.20 / 340.61 | 2 | 7 |
3 | 7 | 1872.16 | 33 | 14.80 | 2847 | 1390 | 1.59 / 342.00 | 2 | 9 |
4 | 13 | 1349.28 | 20 | 14.87 | 2187 | 650 | 2.24 / 342.65 | 2 | 5 |
5 | 13 | 882.16 | 20 | 14.95 | 1570 | 469 | 2.71 / 343.12 | 2 | 9 |
6 | 13 | 326.08 | 20 | 15.06 | 824 | 248 | 2.95 / 343.37 | 2 | 4 |
7 | 13 | 131.28 | 20 | 15.09 | 522 | 158 | 3.11 / 343.53 | 2 | 11 |
8 | 8 | 0.16 | 165 | 15.06 | 312 | 775 | 3.89 / 344.30 | 2 | 16 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 24 | 15.02 | 462 | 167 | 0.17 / 336.77 | 2 | 3 |
2 | 7 | 1873.72 | 33 | 14.80 | 2854 | 1394 | 1.56 / 338.17 | 2 | 15 |
3 | 13 | 1320.92 | 20 | 14.88 | 2147 | 639 | 2.20 / 338.81 | 2 | 6 |
4 | 13 | 797.48 | 20 | 14.98 | 1468 | 440 | 2.64 / 339.25 | 2 | 8 |
5 | 13 | 296.00 | 20 | 15.08 | 779 | 235 | 2.87 / 339.48 | 2 | 4 |
6 | 13 | 142.08 | 20 | 15.09 | 542 | 164 | 3.04 / 339.64 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.06 | 310 | 770 | 3.81 / 340.41 | 2 | 20 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 24 | 15.03 | 467 | 168 | 0.17 / 332.93 | 3 | 8 |
2 | 7 | 1875.12 | 34 | 14.80 | 2827 | 1423 | 1.59 / 334.35 | 2 | 14 |
3 | 13 | 1310.76 | 20 | 14.87 | 2135 | 635 | 2.23 / 334.99 | 2 | 4 |
4 | 13 | 831.16 | 20 | 14.95 | 1507 | 451 | 2.68 / 335.44 | 2 | 7 |
5 | 13 | 284.84 | 20 | 15.08 | 757 | 228 | 2.90 / 335.67 | 2 | 11 |
6 | 13 | 135.84 | 20 | 15.09 | 526 | 159 | 3.06 / 335.83 | 2 | 5 |
7 | 8 | 0.00 | 165 | 15.07 | 314 | 781 | 3.84 / 336.61 | 2 | 72 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 24 | 15.02 | 466 | 168 | 0.17 / 329.07 | 3 | 18 |
2 | 3 | 1016.20 | 1 | 15.14 | 1806 | 27 | 0.20 / 329.10 | 2 | 6 |
3 | 7 | 1877.68 | 33 | 14.81 | 2840 | 1388 | 1.58 / 330.49 | 2 | 7 |
4 | 13 | 1387.28 | 20 | 14.86 | 2230 | 663 | 2.25 / 331.15 | 2 | 10 |
5 | 13 | 760.40 | 20 | 14.97 | 1410 | 422 | 2.67 / 331.57 | 2 | 10 |
6 | 13 | 340.68 | 20 | 15.08 | 842 | 254 | 2.92 / 331.83 | 2 | 6 |
7 | 13 | 144.96 | 20 | 15.09 | 542 | 164 | 3.09 / 331.99 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.06 | 311 | 773 | 3.86 / 332.76 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 24 | 15.03 | 466 | 168 | 0.17 / 325.22 | 3 | 3 |
2 | 7 | 1874.92 | 34 | 14.80 | 2831 | 1425 | 1.59 / 326.64 | 2 | 3 |
3 | 13 | 1298.80 | 20 | 14.89 | 2105 | 627 | 2.22 / 327.27 | 2 | 3 |
4 | 13 | 750.96 | 20 | 14.99 | 1398 | 419 | 2.64 / 327.69 | 2 | 11 |
5 | 13 | 375.64 | 20 | 15.08 | 888 | 268 | 2.91 / 327.96 | 2 | 4 |
6 | 13 | 159.80 | 20 | 15.11 | 568 | 172 | 3.08 / 328.13 | 2 | 31 |
7 | 8 | 0.04 | 165 | 15.06 | 312 | 775 | 3.85 / 328.90 | 2 | 2 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 24 | 15.03 | 473 | 171 | 0.17 / 321.39 | 3 | 3 |
2 | 7 | 1873.48 | 33 | 14.83 | 2852 | 1396 | 1.57 / 322.78 | 2 | 6 |
3 | 13 | 1338.48 | 20 | 14.89 | 2154 | 641 | 2.21 / 323.42 | 2 | 7 |
4 | 13 | 774.92 | 20 | 14.97 | 1429 | 428 | 2.64 / 323.85 | 2 | 7 |
5 | 13 | 388.68 | 20 | 15.06 | 906 | 273 | 2.91 / 324.12 | 2 | 5 |
6 | 13 | 130.48 | 20 | 15.10 | 517 | 156 | 3.06 / 324.28 | 2 | 6 |
7 | 8 | 0.20 | 165 | 15.08 | 309 | 769 | 3.83 / 325.05 | 2 | 83 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 24 | 15.03 | 462 | 167 | 0.17 / 317.40 | 3 | 3 |
2 | 7 | 1882.64 | 33 | 14.80 | 2852 | 1393 | 1.56 / 318.80 | 2 | 3 |
3 | 13 | 1585.64 | 20 | 14.82 | 2480 | 735 | 2.29 / 319.53 | 2 | 7 |
4 | 13 | 919.00 | 20 | 14.92 | 1625 | 485 | 2.78 / 320.02 | 2 | 5 |
5 | 13 | 347.44 | 20 | 15.07 | 863 | 260 | 3.04 / 320.28 | 2 | 2 |
6 | 13 | 138.92 | 20 | 15.09 | 548 | 165 | 3.21 / 320.44 | 2 | 11 |
7 | 8 | 0.04 | 165 | 15.06 | 312 | 775 | 3.98 / 321.22 | 2 | 2 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 24 | 15.04 | 458 | 165 | 0.17 / 313.39 | 3 | 3 |
2 | 7 | 1875.96 | 33 | 14.84 | 2847 | 1394 | 1.56 / 314.78 | 2 | 7 |
3 | 13 | 1420.96 | 20 | 14.86 | 2271 | 675 | 2.23 / 315.45 | 2 | 6 |
4 | 13 | 792.60 | 20 | 14.98 | 1460 | 437 | 2.67 / 315.89 | 2 | 4 |
5 | 13 | 311.04 | 20 | 15.10 | 817 | 247 | 2.92 / 316.14 | 2 | 2 |
6 | 13 | 156.76 | 20 | 15.10 | 573 | 173 | 3.09 / 316.31 | 2 | 26 |
7 | 8 | 0.04 | 165 | 15.08 | 315 | 784 | 3.88 / 317.10 | 2 | 30 |
8 | 14 | 0.04 | 30 | 15.06 | 311 | 141 | 4.02 / 317.24 | 2 | 3 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 24 | 15.03 | 473 | 171 | 0.17 / 309.57 | 3 | 3 |
2 | 7 | 1874.36 | 33 | 14.82 | 2851 | 1394 | 1.56 / 310.96 | 2 | 6 |
3 | 13 | 1324.88 | 20 | 14.89 | 2143 | 638 | 2.20 / 311.60 | 2 | 11 |
4 | 13 | 758.04 | 20 | 14.98 | 1419 | 425 | 2.63 / 312.02 | 2 | 7 |
5 | 13 | 287.40 | 20 | 15.09 | 776 | 234 | 2.86 / 312.26 | 2 | 10 |
6 | 13 | 147.56 | 20 | 15.12 | 556 | 168 | 3.03 / 312.43 | 2 | 23 |
7 | 8 | 0.12 | 165 | 15.08 | 319 | 794 | 3.82 / 313.22 | 2 | 30 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 24 | 15.04 | 466 | 168 | 0.17 / 305.60 | 3 | 3 |
2 | 7 | 1873.08 | 33 | 14.83 | 2837 | 1388 | 1.56 / 306.99 | 2 | 4 |
3 | 13 | 1410.36 | 20 | 14.87 | 2265 | 674 | 2.23 / 307.66 | 2 | 5 |
4 | 13 | 747.32 | 20 | 14.99 | 1404 | 421 | 2.65 / 308.08 | 2 | 7 |
5 | 13 | 334.60 | 20 | 15.09 | 840 | 254 | 2.90 / 308.34 | 2 | 3 |
6 | 13 | 130.20 | 20 | 15.12 | 526 | 159 | 3.06 / 308.50 | 2 | 16 |
7 | 13 | 49.08 | 20 | 15.11 | 396 | 120 | 3.18 / 308.62 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.08 | 313 | 779 | 3.96 / 309.40 | 2 | 16 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 24 | 15.04 | 469 | 169 | 0.17 / 301.73 | 3 | 3 |
2 | 7 | 1876.68 | 33 | 14.83 | 2883 | 1411 | 1.58 / 303.14 | 2 | 9 |
3 | 13 | 1333.60 | 20 | 14.89 | 2167 | 645 | 2.23 / 303.79 | 2 | 9 |
4 | 13 | 811.68 | 20 | 14.99 | 1489 | 446 | 2.67 / 304.24 | 2 | 8 |
5 | 13 | 319.92 | 20 | 15.11 | 826 | 250 | 2.92 / 304.49 | 2 | 2 |
6 | 13 | 113.24 | 20 | 15.13 | 506 | 153 | 3.07 / 304.64 | 2 | 27 |
7 | 8 | 0.16 | 165 | 15.09 | 319 | 794 | 3.87 / 305.43 | 2 | 5 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 24 | 15.04 | 477 | 172 | 0.17 / 297.72 | 3 | 3 |
2 | 7 | 1874.08 | 33 | 14.83 | 2841 | 1390 | 1.56 / 299.11 | 2 | 4 |
3 | 13 | 1328.52 | 20 | 14.90 | 2159 | 643 | 2.21 / 299.75 | 2 | 7 |
4 | 13 | 846.04 | 20 | 14.96 | 1532 | 458 | 2.66 / 300.21 | 2 | 3 |
5 | 13 | 379.84 | 20 | 15.08 | 909 | 274 | 2.94 / 300.48 | 2 | 3 |
6 | 13 | 102.88 | 20 | 15.13 | 491 | 149 | 3.09 / 300.63 | 2 | 2 |
7 | 13 | 64.16 | 20 | 15.12 | 426 | 129 | 3.22 / 300.76 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.08 | 323 | 804 | 4.02 / 301.56 | 2 | 2 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 24 | 15.04 | 476 | 172 | 0.17 / 293.70 | 3 | 3 |
2 | 7 | 1873.84 | 33 | 14.82 | 2861 | 1399 | 1.57 / 295.10 | 2 | 3 |
3 | 13 | 1395.60 | 20 | 14.88 | 2220 | 661 | 2.23 / 295.76 | 2 | 3 |
4 | 13 | 865.16 | 20 | 14.95 | 1563 | 467 | 2.70 / 296.23 | 2 | 5 |
5 | 13 | 319.96 | 20 | 15.11 | 828 | 250 | 2.95 / 296.48 | 2 | 7 |
6 | 13 | 117.40 | 20 | 15.12 | 509 | 154 | 3.10 / 296.64 | 2 | 3 |
7 | 13 | 38.16 | 20 | 15.12 | 383 | 116 | 3.22 / 296.75 | 2 | 6 |
8 | 8 | 0.00 | 165 | 15.08 | 319 | 794 | 4.01 / 297.54 | 2 | 28 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 24 | 15.03 | 478 | 172 | 0.17 / 289.78 | 3 | 3 |
2 | 7 | 1872.00 | 33 | 14.82 | 2840 | 1389 | 1.56 / 291.17 | 2 | 6 |
3 | 13 | 1363.40 | 20 | 14.86 | 2204 | 655 | 2.22 / 291.82 | 2 | 6 |
4 | 13 | 775.72 | 20 | 14.99 | 1445 | 433 | 2.65 / 292.25 | 2 | 3 |
5 | 13 | 293.28 | 20 | 15.11 | 784 | 237 | 2.89 / 292.49 | 2 | 7 |
6 | 13 | 106.24 | 20 | 15.12 | 493 | 149 | 3.04 / 292.64 | 2 | 4 |
7 | 13 | 30.96 | 20 | 15.12 | 369 | 112 | 3.15 / 292.75 | 2 | 9 |
8 | 8 | 0.08 | 165 | 15.07 | 314 | 781 | 3.93 / 293.53 | 2 | 2 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 24 | 15.05 | 464 | 168 | 0.17 / 285.83 | 3 | 3 |
2 | 7 | 1873.88 | 33 | 14.82 | 2832 | 1385 | 1.55 / 287.22 | 2 | 8 |
3 | 13 | 1367.20 | 20 | 14.88 | 2190 | 652 | 2.20 / 287.87 | 2 | 5 |
4 | 13 | 748.80 | 20 | 15.00 | 1405 | 421 | 2.63 / 288.29 | 2 | 4 |
5 | 13 | 320.28 | 20 | 15.10 | 825 | 249 | 2.88 / 288.54 | 2 | 7 |
6 | 13 | 116.08 | 20 | 15.13 | 511 | 155 | 3.03 / 288.69 | 2 | 3 |
7 | 13 | 33.08 | 20 | 15.13 | 376 | 114 | 3.14 / 288.81 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.09 | 320 | 797 | 3.94 / 289.60 | 2 | 3 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 24 | 15.06 | 460 | 166 | 0.17 / 281.82 | 3 | 3 |
2 | 7 | 1873.92 | 33 | 14.83 | 2840 | 1390 | 1.56 / 283.21 | 2 | 4 |
3 | 13 | 1475.80 | 20 | 14.86 | 2348 | 698 | 2.25 / 283.91 | 2 | 5 |
4 | 13 | 823.00 | 20 | 14.97 | 1509 | 452 | 2.71 / 284.36 | 2 | 4 |
5 | 13 | 334.60 | 20 | 15.11 | 841 | 254 | 2.96 / 284.62 | 2 | 3 |
6 | 13 | 123.44 | 20 | 15.14 | 520 | 157 | 3.12 / 284.78 | 2 | 2 |
7 | 13 | 18.68 | 20 | 15.14 | 351 | 106 | 3.22 / 284.88 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.10 | 314 | 782 | 4.01 / 285.66 | 2 | 3 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 24 | 15.05 | 459 | 166 | 0.17 / 278.02 | 3 | 3 |
2 | 7 | 1874.68 | 34 | 14.83 | 2840 | 1432 | 1.60 / 279.45 | 2 | 8 |
3 | 13 | 1282.44 | 20 | 14.90 | 2109 | 628 | 2.23 / 280.08 | 2 | 5 |
4 | 13 | 693.68 | 20 | 15.02 | 1330 | 400 | 2.63 / 280.48 | 2 | 4 |
5 | 13 | 276.88 | 20 | 15.12 | 746 | 226 | 2.85 / 280.70 | 2 | 3 |
6 | 13 | 119.08 | 20 | 15.14 | 524 | 159 | 3.01 / 280.86 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.11 | 320 | 798 | 3.81 / 281.66 | 2 | 8 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 24 | 15.06 | 460 | 166 | 0.17 / 274.09 | 3 | 3 |
2 | 7 | 1872.64 | 33 | 14.84 | 2851 | 1396 | 1.56 / 275.48 | 2 | 8 |
3 | 13 | 1371.68 | 20 | 14.89 | 2212 | 659 | 2.22 / 276.14 | 2 | 5 |
4 | 13 | 775.52 | 20 | 15.01 | 1449 | 435 | 2.66 / 276.58 | 2 | 5 |
5 | 13 | 258.00 | 20 | 15.14 | 727 | 220 | 2.88 / 276.80 | 2 | 4 |
6 | 13 | 105.88 | 20 | 15.16 | 498 | 151 | 3.03 / 276.95 | 2 | 6 |
7 | 13 | 13.76 | 20 | 15.16 | 347 | 105 | 3.13 / 277.05 | 2 | 27 |
8 | 8 | 0.00 | 165 | 15.11 | 319 | 795 | 3.93 / 277.85 | 2 | 2 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 24 | 15.07 | 466 | 169 | 0.17 / 270.12 | 3 | 3 |
2 | 7 | 1872.56 | 33 | 14.84 | 2826 | 1384 | 1.55 / 271.50 | 2 | 3 |
3 | 13 | 1336.76 | 20 | 14.90 | 2168 | 646 | 2.20 / 272.15 | 2 | 5 |
4 | 13 | 875.92 | 20 | 14.96 | 1579 | 472 | 2.67 / 272.62 | 2 | 3 |
5 | 13 | 330.68 | 20 | 15.10 | 836 | 252 | 2.92 / 272.87 | 2 | 5 |
6 | 13 | 116.88 | 20 | 15.15 | 511 | 155 | 3.08 / 273.02 | 2 | 3 |
7 | 13 | 15.96 | 20 | 15.14 | 347 | 105 | 3.18 / 273.13 | 2 | 6 |
8 | 8 | 0.08 | 165 | 15.10 | 318 | 792 | 3.98 / 273.92 | 2 | 28 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 24 | 15.07 | 470 | 170 | 0.17 / 266.15 | 3 | 3 |
2 | 7 | 1873.76 | 33 | 14.85 | 2833 | 1388 | 1.56 / 267.54 | 2 | 4 |
3 | 13 | 1469.32 | 20 | 14.88 | 2336 | 695 | 2.25 / 268.24 | 2 | 5 |
4 | 13 | 761.52 | 20 | 15.01 | 1422 | 427 | 2.68 / 268.66 | 2 | 4 |
5 | 13 | 338.96 | 20 | 15.11 | 850 | 257 | 2.94 / 268.92 | 2 | 3 |
6 | 13 | 87.32 | 20 | 15.16 | 464 | 141 | 3.08 / 269.06 | 2 | 12 |
7 | 13 | 22.52 | 20 | 15.16 | 359 | 109 | 3.19 / 269.17 | 2 | 8 |
8 | 8 | 0.04 | 165 | 15.12 | 312 | 778 | 3.97 / 269.95 | 2 | 15 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 24 | 15.06 | 463 | 167 | 0.17 / 262.19 | 3 | 3 |
2 | 7 | 1874.40 | 33 | 14.83 | 2846 | 1393 | 1.56 / 263.58 | 2 | 4 |
3 | 13 | 1320.84 | 20 | 14.90 | 2149 | 640 | 2.20 / 264.22 | 2 | 3 |
4 | 13 | 770.60 | 20 | 15.00 | 1430 | 429 | 2.63 / 264.65 | 2 | 6 |
5 | 13 | 378.96 | 20 | 15.10 | 909 | 275 | 2.90 / 264.92 | 2 | 4 |
6 | 13 | 107.04 | 20 | 15.15 | 498 | 151 | 3.05 / 265.08 | 2 | 2 |
7 | 13 | 26.40 | 20 | 15.16 | 371 | 112 | 3.17 / 265.19 | 2 | 2 |
8 | 8 | -0.04 | 165 | 15.12 | 318 | 793 | 3.96 / 265.98 | 2 | 7 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 24 | 15.07 | 477 | 173 | 0.17 / 258.19 | 3 | 3 |
2 | 7 | 1873.88 | 34 | 14.83 | 2848 | 1436 | 1.61 / 259.62 | 2 | 3 |
3 | 13 | 1286.16 | 20 | 14.91 | 2091 | 624 | 2.23 / 260.24 | 2 | 3 |
4 | 13 | 843.12 | 20 | 14.98 | 1528 | 458 | 2.69 / 260.70 | 2 | 4 |
5 | 13 | 299.32 | 20 | 15.14 | 799 | 242 | 2.93 / 260.94 | 2 | 4 |
6 | 13 | 132.64 | 20 | 15.17 | 541 | 164 | 3.10 / 261.11 | 2 | 3 |
7 | 13 | 18.76 | 20 | 15.17 | 358 | 109 | 3.20 / 261.22 | 2 | 15 |
8 | 8 | 0.12 | 165 | 15.12 | 322 | 803 | 4.01 / 262.02 | 2 | 17 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 24 | 15.09 | 454 | 164 | 0.16 / 254.44 | 3 | 3 |
2 | 7 | 1874.12 | 33 | 14.83 | 2814 | 1377 | 1.54 / 255.82 | 2 | 2 |
3 | 13 | 1311.08 | 20 | 14.91 | 2130 | 635 | 2.18 / 256.45 | 2 | 6 |
4 | 13 | 724.60 | 20 | 15.02 | 1353 | 406 | 2.58 / 256.86 | 2 | 4 |
5 | 13 | 291.60 | 20 | 15.15 | 758 | 230 | 2.81 / 257.09 | 2 | 4 |
6 | 13 | 92.84 | 20 | 15.17 | 465 | 141 | 2.95 / 257.23 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.13 | 313 | 781 | 3.74 / 258.01 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 24 | 15.11 | 462 | 168 | 0.17 / 250.65 | 3 | 3 |
2 | 7 | 1878.56 | 33 | 14.83 | 2842 | 1391 | 1.56 / 252.04 | 2 | 8 |
3 | 13 | 1391.72 | 20 | 14.91 | 2223 | 663 | 2.22 / 252.71 | 2 | 5 |
4 | 13 | 720.76 | 20 | 15.05 | 1343 | 404 | 2.63 / 253.11 | 2 | 4 |
5 | 13 | 302.60 | 20 | 15.16 | 780 | 236 | 2.86 / 253.35 | 2 | 5 |
6 | 13 | 102.12 | 20 | 15.18 | 467 | 142 | 3.00 / 253.49 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.15 | 315 | 787 | 3.79 / 254.28 | 2 | 16 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 24 | 15.10 | 467 | 169 | 0.17 / 246.97 | 3 | 3 |
2 | 7 | 1499.52 | 33 | 14.99 | 2374 | 1174 | 1.34 / 248.15 | 2 | 3 |
3 | 13 | 1366.00 | 20 | 14.98 | 2208 | 662 | 2.01 / 248.81 | 2 | 4 |
4 | 13 | 852.16 | 20 | 15.06 | 1544 | 465 | 2.47 / 249.28 | 2 | 3 |
5 | 13 | 323.16 | 20 | 15.17 | 826 | 251 | 2.72 / 249.53 | 2 | 4 |
6 | 13 | 103.32 | 20 | 15.21 | 493 | 150 | 2.87 / 249.68 | 2 | 11 |
7 | 8 | 0.16 | 165 | 15.16 | 324 | 810 | 3.68 / 250.49 | 2 | 10 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 24 | 15.10 | 469 | 170 | 0.17 / 242.99 | 3 | 3 |
2 | 7 | 1874.52 | 33 | 14.85 | 2840 | 1392 | 1.56 / 244.38 | 2 | 3 |
3 | 13 | 1378.64 | 20 | 14.90 | 2235 | 666 | 2.23 / 245.04 | 2 | 3 |
4 | 13 | 808.84 | 20 | 15.01 | 1493 | 448 | 2.68 / 245.49 | 2 | 3 |
5 | 13 | 324.76 | 20 | 15.16 | 837 | 254 | 2.93 / 245.75 | 2 | 3 |
6 | 13 | 108.80 | 20 | 15.18 | 501 | 152 | 3.08 / 245.90 | 2 | 4 |
7 | 13 | 13.68 | 20 | 15.19 | 348 | 106 | 3.19 / 246.00 | 2 | 13 |
8 | 8 | -0.04 | 165 | 15.14 | 321 | 802 | 3.99 / 246.81 | 2 | 3 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 24 | 15.09 | 463 | 168 | 0.17 / 239.16 | 3 | 3 |
2 | 7 | 1871.92 | 33 | 14.85 | 2832 | 1388 | 1.56 / 240.55 | 2 | 5 |
3 | 13 | 1321.12 | 20 | 14.93 | 2144 | 640 | 2.20 / 241.19 | 2 | 6 |
4 | 13 | 751.24 | 20 | 15.05 | 1407 | 424 | 2.62 / 241.61 | 2 | 3 |
5 | 13 | 306.16 | 20 | 15.17 | 805 | 244 | 2.86 / 241.86 | 2 | 3 |
6 | 13 | 100.64 | 20 | 15.21 | 492 | 150 | 3.01 / 242.01 | 2 | 5 |
7 | 8 | 0.12 | 165 | 15.15 | 324 | 810 | 3.82 / 242.82 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 24 | 15.11 | 475 | 172 | 0.17 / 235.18 | 3 | 3 |
2 | 7 | 1875.44 | 33 | 14.85 | 2859 | 1401 | 1.57 / 236.58 | 2 | 3 |
3 | 13 | 1320.36 | 20 | 14.92 | 2153 | 642 | 2.22 / 237.22 | 2 | 5 |
4 | 13 | 793.08 | 20 | 15.04 | 1470 | 442 | 2.66 / 237.66 | 2 | 4 |
5 | 13 | 347.08 | 20 | 15.15 | 869 | 263 | 2.92 / 237.93 | 2 | 4 |
6 | 13 | 125.56 | 20 | 15.19 | 528 | 160 | 3.08 / 238.09 | 2 | 6 |
7 | 13 | 17.52 | 20 | 15.20 | 355 | 108 | 3.19 / 238.20 | 2 | 8 |
8 | 8 | 0.00 | 165 | 15.15 | 319 | 797 | 3.99 / 238.99 | 2 | 15 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 24 | 15.12 | 470 | 171 | 0.17 / 231.17 | 3 | 3 |
2 | 7 | 1871.24 | 33 | 14.87 | 2830 | 1389 | 1.56 / 232.56 | 2 | 6 |
3 | 13 | 1344.88 | 20 | 14.94 | 2184 | 653 | 2.21 / 233.21 | 2 | 4 |
4 | 13 | 847.76 | 20 | 15.03 | 1549 | 466 | 2.68 / 233.67 | 2 | 4 |
5 | 13 | 350.64 | 20 | 15.18 | 869 | 264 | 2.94 / 233.94 | 2 | 3 |
6 | 13 | 144.04 | 20 | 15.20 | 552 | 168 | 3.11 / 234.11 | 2 | 4 |
7 | 13 | 23.00 | 20 | 15.20 | 361 | 110 | 3.22 / 234.22 | 2 | 6 |
8 | 8 | 0.08 | 165 | 15.16 | 316 | 790 | 4.01 / 235.01 | 2 | 5 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 24 | 15.12 | 449 | 163 | 0.16 / 227.35 | 3 | 3 |
2 | 7 | 1871.04 | 33 | 14.85 | 2850 | 1397 | 1.56 / 228.75 | 2 | 5 |
3 | 13 | 1347.08 | 20 | 14.92 | 2201 | 657 | 2.22 / 229.41 | 2 | 3 |
4 | 13 | 661.04 | 20 | 15.08 | 1290 | 389 | 2.61 / 229.80 | 2 | 4 |
5 | 13 | 307.52 | 20 | 15.19 | 806 | 245 | 2.85 / 230.04 | 2 | 3 |
6 | 13 | 111.68 | 20 | 15.21 | 501 | 152 | 3.00 / 230.19 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.17 | 321 | 803 | 3.81 / 231.00 | 2 | 8 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 24 | 15.12 | 461 | 167 | 0.17 / 223.36 | 3 | 3 |
2 | 3 | 978.88 | -1 | 15.56 | 0 | 0 | 0.00 / 223.36 | 3 | 3 |
3 | 3 | 1022.00 | 1 | 15.24 | 1856 | 28 | 0.20 / 223.38 | 2 | 2 |
4 | 7 | 1875.80 | 33 | 14.87 | 2842 | 1395 | 1.59 / 224.78 | 2 | 3 |
5 | 13 | 1316.68 | 20 | 14.95 | 2157 | 645 | 2.24 / 225.42 | 2 | 4 |
6 | 13 | 775.20 | 20 | 15.06 | 1451 | 437 | 2.67 / 225.86 | 2 | 4 |
7 | 13 | 352.32 | 20 | 15.18 | 874 | 265 | 2.94 / 226.13 | 2 | 4 |
8 | 13 | 132.72 | 20 | 15.21 | 539 | 164 | 3.10 / 226.29 | 2 | 6 |
9 | 13 | 19.64 | 20 | 15.22 | 358 | 109 | 3.21 / 226.40 | 2 | 3 |
10 | 8 | 0.08 | 165 | 15.17 | 316 | 791 | 4.00 / 227.19 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 24 | 15.13 | 466 | 169 | 0.17 / 219.56 | 3 | 3 |
2 | 7 | 1873.76 | 33 | 14.85 | 2845 | 1394 | 1.56 / 220.95 | 2 | 4 |
3 | 13 | 1388.12 | 20 | 14.93 | 2251 | 672 | 2.24 / 221.62 | 2 | 5 |
4 | 13 | 672.16 | 20 | 15.09 | 1317 | 397 | 2.63 / 222.02 | 2 | 4 |
5 | 13 | 252.56 | 20 | 15.21 | 727 | 221 | 2.85 / 222.24 | 2 | 4 |
6 | 13 | 118.68 | 20 | 15.22 | 514 | 156 | 3.01 / 222.40 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.18 | 316 | 791 | 3.80 / 223.19 | 2 | 5 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 24 | 15.12 | 470 | 171 | 0.17 / 215.58 | 3 | 3 |
2 | 7 | 1871.24 | 33 | 14.84 | 2837 | 1389 | 1.56 / 216.97 | 2 | 3 |
3 | 13 | 1364.32 | 20 | 14.92 | 2200 | 656 | 2.22 / 217.63 | 2 | 3 |
4 | 13 | 840.12 | 20 | 15.03 | 1536 | 462 | 2.68 / 218.09 | 2 | 3 |
5 | 13 | 290.32 | 20 | 15.18 | 785 | 238 | 2.92 / 218.33 | 2 | 4 |
6 | 13 | 100.48 | 20 | 15.22 | 489 | 149 | 3.07 / 218.48 | 2 | 4 |
7 | 13 | 25.68 | 20 | 15.21 | 366 | 111 | 3.18 / 218.59 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.16 | 319 | 798 | 3.97 / 219.39 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 24 | 15.14 | 471 | 171 | 0.17 / 211.71 | 3 | 3 |
2 | 7 | 1873.76 | 33 | 14.87 | 2853 | 1400 | 1.57 / 213.11 | 2 | 4 |
3 | 13 | 1364.04 | 20 | 14.95 | 2220 | 664 | 2.23 / 213.78 | 2 | 4 |
4 | 13 | 729.04 | 20 | 15.07 | 1391 | 419 | 2.65 / 214.20 | 2 | 4 |
5 | 13 | 297.24 | 20 | 15.20 | 795 | 242 | 2.90 / 214.44 | 2 | 3 |
6 | 13 | 143.48 | 20 | 15.21 | 561 | 171 | 3.07 / 214.61 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.18 | 321 | 804 | 3.87 / 215.41 | 2 | 15 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 24 | 15.14 | 466 | 169 | 0.17 / 207.84 | 3 | 3 |
2 | 3 | 1018.12 | 1 | 15.25 | 1837 | 28 | 0.20 / 207.86 | 2 | 3 |
3 | 7 | 1873.80 | 33 | 14.87 | 2846 | 1397 | 1.59 / 209.26 | 2 | 3 |
4 | 13 | 1331.92 | 20 | 14.93 | 2174 | 649 | 2.24 / 209.91 | 2 | 5 |
5 | 13 | 703.08 | 20 | 15.09 | 1354 | 409 | 2.65 / 210.32 | 2 | 4 |
6 | 13 | 321.16 | 20 | 15.20 | 832 | 253 | 2.90 / 210.57 | 2 | 4 |
7 | 13 | 119.84 | 20 | 15.21 | 521 | 158 | 3.06 / 210.73 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.18 | 324 | 812 | 3.87 / 211.54 | 3 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 24 | 15.14 | 483 | 176 | 0.18 / 204.05 | 3 | 3 |
2 | 7 | 1873.28 | 34 | 14.86 | 2847 | 1438 | 1.61 / 205.49 | 2 | 3 |
3 | 13 | 1225.08 | 20 | 14.97 | 2025 | 606 | 2.22 / 206.10 | 2 | 3 |
4 | 13 | 661.68 | 20 | 15.11 | 1298 | 392 | 2.61 / 206.49 | 2 | 4 |
5 | 13 | 260.60 | 20 | 15.20 | 737 | 224 | 2.84 / 206.71 | 2 | 4 |
6 | 13 | 117.56 | 20 | 15.21 | 508 | 155 | 2.99 / 206.87 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.18 | 319 | 799 | 3.79 / 207.67 | 2 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 24 | 15.15 | 485 | 176 | 0.18 / 200.17 | 3 | 3 |
2 | 7 | 1873.72 | 33 | 14.86 | 2841 | 1393 | 1.57 / 201.57 | 2 | 4 |
3 | 13 | 1321.36 | 20 | 14.95 | 2139 | 640 | 2.21 / 202.21 | 2 | 5 |
4 | 13 | 790.00 | 20 | 15.08 | 1466 | 442 | 2.65 / 202.65 | 2 | 4 |
5 | 13 | 291.84 | 20 | 15.22 | 784 | 239 | 2.89 / 202.89 | 2 | 3 |
6 | 13 | 135.32 | 20 | 15.22 | 547 | 167 | 3.06 / 203.05 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.19 | 328 | 822 | 3.88 / 203.88 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 23 | 15.15 | 479 | 167 | 0.17 / 196.25 | 3 | 3 |
2 | 7 | 1874.80 | 33 | 14.89 | 2823 | 1387 | 1.55 / 197.64 | 2 | 6 |
3 | 13 | 1478.36 | 20 | 14.93 | 2367 | 707 | 2.26 / 198.34 | 2 | 4 |
4 | 13 | 724.96 | 20 | 15.10 | 1383 | 418 | 2.68 / 198.76 | 2 | 3 |
5 | 13 | 293.04 | 20 | 15.22 | 793 | 241 | 2.92 / 199.00 | 2 | 4 |
6 | 13 | 137.12 | 20 | 15.24 | 552 | 168 | 3.09 / 199.17 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.20 | 330 | 828 | 3.92 / 200.00 | 2 | 11 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 24 | 15.15 | 480 | 175 | 0.17 / 192.36 | 3 | 3 |
2 | 7 | 1874.24 | 33 | 14.88 | 2856 | 1402 | 1.58 / 193.76 | 2 | 3 |
3 | 13 | 1429.32 | 20 | 14.94 | 2286 | 683 | 2.26 / 194.44 | 2 | 3 |
4 | 13 | 702.84 | 20 | 15.11 | 1355 | 409 | 2.67 / 194.85 | 2 | 5 |
5 | 13 | 324.84 | 20 | 15.22 | 843 | 257 | 2.93 / 195.11 | 2 | 4 |
6 | 13 | 120.64 | 20 | 15.23 | 523 | 159 | 3.09 / 195.27 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.20 | 325 | 815 | 3.90 / 196.08 | 2 | 4 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 23 | 15.16 | 484 | 169 | 0.17 / 188.54 | 3 | 3 |
2 | 7 | 1871.96 | 33 | 14.88 | 2855 | 1402 | 1.57 / 189.95 | 2 | 3 |
3 | 13 | 1229.16 | 20 | 14.99 | 2020 | 606 | 2.18 / 190.55 | 2 | 3 |
4 | 13 | 775.68 | 20 | 15.09 | 1448 | 437 | 2.61 / 190.99 | 2 | 4 |
5 | 13 | 239.16 | 20 | 15.24 | 715 | 218 | 2.83 / 191.21 | 2 | 4 |
6 | 13 | 144.36 | 20 | 15.23 | 560 | 171 | 3.00 / 191.38 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.19 | 321 | 805 | 3.81 / 192.18 | 2 | 3 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 23 | 15.17 | 482 | 168 | 0.17 / 184.69 | 3 | 3 |
2 | 7 | 1873.80 | 33 | 14.88 | 2832 | 1391 | 1.56 / 186.08 | 2 | 5 |
3 | 13 | 1323.04 | 20 | 14.96 | 2161 | 647 | 2.21 / 186.73 | 2 | 5 |
4 | 13 | 751.16 | 20 | 15.10 | 1411 | 426 | 2.63 / 187.15 | 2 | 4 |
5 | 13 | 322.52 | 20 | 15.20 | 832 | 253 | 2.88 / 187.41 | 2 | 3 |
6 | 13 | 118.64 | 20 | 15.23 | 519 | 158 | 3.04 / 187.56 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.19 | 324 | 812 | 3.85 / 188.38 | 2 | 4 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 24 | 15.15 | 493 | 179 | 0.18 / 180.84 | 3 | 3 |
2 | 7 | 1875.72 | 33 | 14.90 | 2844 | 1398 | 1.58 / 182.24 | 2 | 4 |
3 | 13 | 1317.92 | 20 | 14.98 | 2149 | 644 | 2.22 / 182.88 | 2 | 3 |
4 | 13 | 752.68 | 20 | 15.11 | 1420 | 429 | 2.65 / 183.31 | 2 | 4 |
5 | 13 | 281.56 | 20 | 15.23 | 769 | 234 | 2.88 / 183.55 | 2 | 4 |
6 | 13 | 125.00 | 20 | 15.25 | 530 | 162 | 3.05 / 183.71 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.22 | 324 | 814 | 3.86 / 184.52 | 2 | 7 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 24 | 15.16 | 489 | 178 | 0.18 / 176.87 | 3 | 3 |
2 | 7 | 1871.64 | 33 | 14.89 | 2837 | 1394 | 1.57 / 178.26 | 2 | 3 |
3 | 13 | 1480.04 | 20 | 14.96 | 2354 | 704 | 2.28 / 178.97 | 2 | 5 |
4 | 13 | 813.08 | 20 | 15.10 | 1487 | 449 | 2.73 / 179.42 | 2 | 4 |
5 | 13 | 312.24 | 20 | 15.23 | 818 | 249 | 2.97 / 179.67 | 2 | 3 |
6 | 13 | 155.76 | 20 | 15.24 | 575 | 175 | 3.15 / 179.84 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.21 | 327 | 821 | 3.97 / 180.66 | 2 | 6 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 24 | 15.17 | 476 | 173 | 0.17 / 172.98 | 3 | 3 |
2 | 7 | 1873.28 | 33 | 14.88 | 2830 | 1390 | 1.56 / 174.37 | 2 | 3 |
3 | 13 | 1347.76 | 20 | 14.96 | 2183 | 653 | 2.22 / 175.02 | 2 | 3 |
4 | 13 | 822.80 | 20 | 15.08 | 1519 | 458 | 2.67 / 175.48 | 2 | 4 |
5 | 13 | 282.12 | 20 | 15.22 | 773 | 235 | 2.91 / 175.71 | 2 | 4 |
6 | 13 | 130.08 | 20 | 15.25 | 534 | 163 | 3.07 / 175.88 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.21 | 324 | 813 | 3.89 / 176.69 | 2 | 5 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 24 | 15.18 | 479 | 175 | 0.17 / 169.12 | 3 | 3 |
2 | 7 | 1874.80 | 33 | 14.89 | 2833 | 1392 | 1.57 / 170.51 | 2 | 4 |
3 | 13 | 1310.92 | 20 | 14.98 | 2123 | 636 | 2.20 / 171.15 | 2 | 5 |
4 | 13 | 809.72 | 20 | 15.10 | 1492 | 451 | 2.65 / 171.60 | 2 | 4 |
5 | 13 | 272.04 | 20 | 15.23 | 757 | 231 | 2.88 / 171.83 | 2 | 4 |
6 | 13 | 121.12 | 20 | 15.25 | 524 | 160 | 3.04 / 171.99 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.22 | 326 | 819 | 3.86 / 172.81 | 2 | 8 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 24 | 15.16 | 464 | 169 | 0.17 / 165.22 | 3 | 3 |
2 | 7 | 1874.84 | 34 | 14.88 | 2838 | 1436 | 1.60 / 166.66 | 2 | 4 |
3 | 13 | 1310.76 | 20 | 14.98 | 2132 | 639 | 2.24 / 167.30 | 2 | 4 |
4 | 13 | 824.48 | 20 | 15.10 | 1502 | 454 | 2.70 / 167.75 | 2 | 3 |
5 | 13 | 264.36 | 20 | 15.25 | 741 | 226 | 2.92 / 167.98 | 2 | 4 |
6 | 13 | 125.16 | 20 | 15.25 | 523 | 160 | 3.08 / 168.14 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.22 | 321 | 806 | 3.89 / 168.94 | 2 | 3 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 24 | 15.18 | 470 | 171 | 0.17 / 161.22 | 3 | 3 |
2 | 7 | 1873.88 | 33 | 14.87 | 2854 | 1400 | 1.57 / 162.62 | 2 | 3 |
3 | 13 | 1399.16 | 20 | 14.95 | 2266 | 678 | 2.25 / 163.30 | 2 | 4 |
4 | 13 | 752.16 | 20 | 15.10 | 1414 | 427 | 2.68 / 163.73 | 2 | 5 |
5 | 13 | 323.28 | 20 | 15.22 | 836 | 254 | 2.93 / 163.98 | 2 | 5 |
6 | 13 | 115.16 | 20 | 15.25 | 519 | 158 | 3.09 / 164.14 | 2 | 3 |
7 | 13 | 13.60 | 20 | 15.24 | 354 | 108 | 3.20 / 164.25 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.21 | 321 | 806 | 4.00 / 165.05 | 2 | 6 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 23 | 15.19 | 464 | 162 | 0.16 / 157.30 | 3 | 3 |
2 | 10 | 1001.68 | 2 | 15.24 | 1787 | 54 | 0.22 / 157.35 | 2 | 3 |
3 | 3 | 951.92 | -1 | 15.60 | 1 | 0 | 0.05 / 157.35 | 2 | 3 |
4 | 7 | 1874.88 | 33 | 14.90 | 2839 | 1396 | 1.61 / 158.75 | 2 | 6 |
5 | 13 | 1310.28 | 20 | 14.99 | 2145 | 643 | 2.26 / 159.39 | 2 | 3 |
6 | 13 | 616.20 | 20 | 15.16 | 1240 | 376 | 2.63 / 159.77 | 2 | 4 |
7 | 13 | 227.56 | 20 | 15.26 | 685 | 209 | 2.84 / 159.98 | 2 | 3 |
8 | 13 | 85.40 | 20 | 15.25 | 458 | 140 | 2.98 / 160.12 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.22 | 315 | 791 | 3.77 / 160.91 | 2 | 5 |
10 | 14 | 0.08 | 30 | 15.19 | 313 | 143 | 3.91 / 161.05 | 2 | 7 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 23 | 15.19 | 479 | 167 | 0.17 / 153.52 | 3 | 3 |
2 | 7 | 1871.36 | 33 | 14.87 | 2858 | 1402 | 1.57 / 154.92 | 2 | 4 |
3 | 13 | 1322.48 | 20 | 15.00 | 2145 | 643 | 2.21 / 155.56 | 2 | 4 |
4 | 13 | 740.72 | 20 | 15.12 | 1391 | 421 | 2.63 / 155.98 | 2 | 4 |
5 | 13 | 200.64 | 20 | 15.26 | 648 | 198 | 2.83 / 156.18 | 2 | 3 |
6 | 13 | 107.44 | 20 | 15.27 | 498 | 152 | 2.98 / 156.33 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.23 | 320 | 804 | 3.79 / 157.14 | 2 | 5 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 23 | 15.19 | 484 | 169 | 0.17 / 149.79 | 3 | 3 |
2 | 7 | 1874.88 | 33 | 14.92 | 2845 | 1401 | 1.57 / 151.19 | 2 | 4 |
3 | 13 | 1191.68 | 20 | 15.02 | 1995 | 599 | 2.17 / 151.79 | 2 | 3 |
4 | 13 | 668.40 | 20 | 15.14 | 1303 | 395 | 2.56 / 152.18 | 2 | 4 |
5 | 13 | 234.92 | 20 | 15.26 | 698 | 213 | 2.78 / 152.40 | 2 | 4 |
6 | 13 | 102.08 | 20 | 15.25 | 481 | 147 | 2.92 / 152.54 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.22 | 321 | 806 | 3.73 / 153.35 | 2 | 6 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 23 | 15.19 | 481 | 168 | 0.17 / 146.02 | 3 | 3 |
2 | 7 | 1871.52 | 33 | 14.91 | 2859 | 1407 | 1.57 / 147.43 | 2 | 3 |
3 | 13 | 1296.04 | 20 | 15.02 | 2114 | 635 | 2.21 / 148.06 | 2 | 3 |
4 | 13 | 739.32 | 20 | 15.15 | 1405 | 426 | 2.64 / 148.49 | 2 | 4 |
5 | 13 | 200.52 | 20 | 15.27 | 639 | 195 | 2.83 / 148.68 | 2 | 3 |
6 | 13 | 72.00 | 20 | 15.27 | 437 | 133 | 2.96 / 148.82 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.23 | 320 | 804 | 3.77 / 149.62 | 2 | 5 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 23 | 15.17 | 477 | 166 | 0.17 / 142.29 | 3 | 3 |
2 | 7 | 1872.52 | 33 | 14.90 | 2861 | 1407 | 1.57 / 143.69 | 2 | 4 |
3 | 13 | 1190.44 | 20 | 15.04 | 1984 | 597 | 2.17 / 144.29 | 2 | 3 |
4 | 13 | 656.20 | 20 | 15.17 | 1293 | 392 | 2.56 / 144.68 | 2 | 3 |
5 | 13 | 232.96 | 20 | 15.27 | 701 | 214 | 2.78 / 144.90 | 2 | 3 |
6 | 13 | 77.76 | 20 | 15.27 | 449 | 137 | 2.91 / 145.03 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.23 | 326 | 819 | 3.73 / 145.85 | 2 | 7 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 23 | 15.19 | 478 | 167 | 0.17 / 138.39 | 3 | 3 |
2 | 7 | 1879.60 | 33 | 14.89 | 2855 | 1403 | 1.57 / 139.80 | 2 | 3 |
3 | 13 | 1443.68 | 20 | 14.97 | 2298 | 688 | 2.26 / 140.48 | 2 | 4 |
4 | 13 | 734.28 | 20 | 15.14 | 1396 | 423 | 2.68 / 140.91 | 2 | 4 |
5 | 13 | 288.12 | 20 | 15.25 | 779 | 238 | 2.92 / 141.14 | 2 | 4 |
6 | 13 | 95.44 | 20 | 15.28 | 484 | 148 | 3.07 / 141.29 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.23 | 329 | 827 | 3.89 / 142.12 | 2 | 6 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 24 | 15.19 | 483 | 176 | 0.18 / 134.42 | 3 | 3 |
2 | 7 | 1884.92 | 33 | 14.91 | 2859 | 1407 | 1.58 / 135.83 | 2 | 4 |
3 | 13 | 1324.80 | 20 | 15.01 | 2155 | 647 | 2.23 / 136.47 | 2 | 4 |
4 | 13 | 746.40 | 20 | 15.16 | 1414 | 429 | 2.66 / 136.90 | 2 | 4 |
5 | 13 | 291.92 | 20 | 15.26 | 793 | 242 | 2.90 / 137.15 | 2 | 3 |
6 | 13 | 95.32 | 20 | 15.28 | 486 | 149 | 3.05 / 137.29 | 2 | 3 |
7 | 13 | 23.88 | 20 | 15.28 | 369 | 113 | 3.16 / 137.41 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.24 | 326 | 820 | 3.98 / 138.23 | 2 | 4 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 24 | 15.21 | 465 | 170 | 0.17 / 130.38 | 3 | 3 |
2 | 7 | 1877.16 | 33 | 14.89 | 2865 | 1408 | 1.58 / 131.78 | 2 | 3 |
3 | 13 | 1601.24 | 20 | 14.94 | 2511 | 750 | 2.33 / 132.53 | 2 | 6 |
4 | 13 | 727.12 | 20 | 15.16 | 1376 | 417 | 2.75 / 132.95 | 2 | 4 |
5 | 13 | 288.64 | 20 | 15.25 | 779 | 238 | 2.98 / 133.19 | 2 | 3 |
6 | 13 | 96.84 | 20 | 15.27 | 480 | 147 | 3.13 / 133.34 | 2 | 3 |
7 | 13 | 28.40 | 20 | 15.26 | 371 | 113 | 3.24 / 133.45 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.23 | 317 | 797 | 4.04 / 134.24 | 2 | 4 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 24 | 15.20 | 478 | 174 | 0.17 / 126.54 | 3 | 3 |
2 | 7 | 1877.60 | 34 | 14.90 | 2861 | 1449 | 1.62 / 127.99 | 2 | 3 |
3 | 13 | 1302.32 | 20 | 15.02 | 2128 | 639 | 2.26 / 128.63 | 2 | 5 |
4 | 13 | 698.56 | 20 | 15.16 | 1336 | 405 | 2.67 / 129.03 | 2 | 3 |
5 | 13 | 257.72 | 20 | 15.28 | 732 | 224 | 2.89 / 129.25 | 2 | 3 |
6 | 13 | 78.88 | 20 | 15.28 | 453 | 138 | 3.03 / 129.39 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.25 | 323 | 813 | 3.84 / 130.21 | 3 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 23 | 15.21 | 471 | 165 | 0.16 / 122.57 | 3 | 3 |
2 | 7 | 1891.72 | 33 | 14.92 | 2835 | 1396 | 1.56 / 123.96 | 2 | 5 |
3 | 13 | 1349.88 | 20 | 15.03 | 2184 | 657 | 2.22 / 124.62 | 2 | 4 |
4 | 13 | 760.64 | 20 | 15.16 | 1428 | 433 | 2.65 / 125.05 | 2 | 5 |
5 | 13 | 316.00 | 20 | 15.27 | 820 | 250 | 2.90 / 125.30 | 2 | 4 |
6 | 13 | 106.88 | 20 | 15.28 | 490 | 150 | 3.05 / 125.45 | 2 | 3 |
7 | 13 | 24.68 | 20 | 15.28 | 364 | 111 | 3.16 / 125.57 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.24 | 317 | 797 | 3.96 / 126.36 | 2 | 6 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 23 | 15.21 | 481 | 168 | 0.17 / 118.71 | 3 | 3 |
2 | 7 | 1884.96 | 33 | 14.90 | 2851 | 1402 | 1.57 / 120.11 | 2 | 4 |
3 | 13 | 1316.92 | 20 | 15.02 | 2143 | 644 | 2.21 / 120.76 | 2 | 3 |
4 | 13 | 858.72 | 20 | 15.12 | 1561 | 472 | 2.69 / 121.23 | 2 | 3 |
5 | 13 | 261.60 | 20 | 15.26 | 736 | 225 | 2.91 / 121.45 | 2 | 3 |
6 | 13 | 93.72 | 20 | 15.27 | 472 | 144 | 3.05 / 121.60 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.25 | 321 | 808 | 3.86 / 122.40 | 2 | 5 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 23 | 15.19 | 484 | 169 | 0.17 / 114.87 | 3 | 3 |
2 | 7 | 1895.48 | 33 | 14.91 | 2875 | 1415 | 1.58 / 116.28 | 2 | 3 |
3 | 13 | 1312.64 | 20 | 15.04 | 2141 | 644 | 2.23 / 116.93 | 2 | 5 |
4 | 13 | 729.44 | 20 | 15.17 | 1386 | 421 | 2.65 / 117.35 | 2 | 4 |
5 | 13 | 278.84 | 20 | 15.28 | 767 | 234 | 2.88 / 117.58 | 2 | 3 |
6 | 13 | 94.64 | 20 | 15.30 | 477 | 146 | 3.03 / 117.73 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.26 | 324 | 816 | 3.84 / 118.54 | 2 | 3 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 23 | 15.22 | 485 | 170 | 0.17 / 110.91 | 3 | 3 |
2 | 7 | 1879.28 | 33 | 14.91 | 2858 | 1406 | 1.58 / 112.31 | 2 | 3 |
3 | 13 | 1309.72 | 20 | 15.03 | 2136 | 642 | 2.22 / 112.95 | 2 | 5 |
4 | 13 | 723.84 | 20 | 15.18 | 1383 | 420 | 2.64 / 113.37 | 2 | 3 |
5 | 13 | 289.84 | 20 | 15.27 | 779 | 238 | 2.88 / 113.61 | 2 | 3 |
6 | 13 | 91.12 | 20 | 15.29 | 477 | 146 | 3.02 / 113.76 | 2 | 3 |
7 | 13 | 22.28 | 20 | 15.29 | 366 | 112 | 3.13 / 113.87 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.25 | 329 | 828 | 3.96 / 114.70 | 2 | 3 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 23 | 15.22 | 475 | 166 | 0.17 / 107.06 | 3 | 3 |
2 | 7 | 1889.76 | 33 | 14.92 | 2882 | 1419 | 1.59 / 108.48 | 2 | 4 |
3 | 13 | 1308.64 | 20 | 15.05 | 2131 | 641 | 2.23 / 109.12 | 2 | 4 |
4 | 13 | 733.56 | 20 | 15.18 | 1388 | 421 | 2.65 / 109.54 | 2 | 4 |
5 | 13 | 294.28 | 20 | 15.28 | 787 | 241 | 2.89 / 109.78 | 2 | 4 |
6 | 13 | 105.12 | 20 | 15.30 | 487 | 149 | 3.04 / 109.93 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.26 | 319 | 803 | 3.84 / 110.74 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 23 | 15.23 | 466 | 163 | 0.16 / 103.22 | 3 | 3 |
2 | 7 | 1893.36 | 33 | 14.92 | 2870 | 1413 | 1.58 / 104.63 | 2 | 3 |
3 | 13 | 1335.48 | 20 | 15.05 | 2166 | 652 | 2.23 / 105.28 | 2 | 5 |
4 | 13 | 740.44 | 20 | 15.17 | 1402 | 425 | 2.65 / 105.71 | 2 | 6 |
5 | 13 | 288.88 | 20 | 15.29 | 781 | 239 | 2.89 / 105.94 | 2 | 3 |
6 | 13 | 98.44 | 20 | 15.30 | 482 | 147 | 3.04 / 106.09 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.26 | 319 | 803 | 3.84 / 106.90 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 23 | 15.21 | 471 | 165 | 0.16 / 99.39 | 3 | 3 |
2 | 7 | 1884.56 | 34 | 14.93 | 2824 | 1434 | 1.60 / 100.82 | 2 | 3 |
3 | 13 | 1306.24 | 20 | 15.04 | 2136 | 643 | 2.24 / 101.46 | 2 | 5 |
4 | 13 | 723.72 | 20 | 15.18 | 1373 | 417 | 2.66 / 101.88 | 2 | 3 |
5 | 13 | 276.20 | 20 | 15.29 | 760 | 232 | 2.89 / 102.11 | 2 | 3 |
6 | 13 | 103.80 | 20 | 15.30 | 481 | 147 | 3.04 / 102.26 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.27 | 314 | 791 | 3.83 / 103.05 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 23 | 15.23 | 477 | 167 | 0.17 / 95.39 | 3 | 3 |
2 | 7 | 1880.44 | 34 | 14.92 | 2865 | 1453 | 1.62 / 96.84 | 2 | 3 |
3 | 13 | 1457.20 | 20 | 15.01 | 2323 | 697 | 2.32 / 97.54 | 2 | 5 |
4 | 13 | 691.40 | 20 | 15.20 | 1340 | 407 | 2.73 / 97.95 | 2 | 4 |
5 | 13 | 261.96 | 20 | 15.30 | 734 | 225 | 2.95 / 98.17 | 2 | 4 |
6 | 13 | 82.72 | 20 | 15.30 | 456 | 140 | 3.09 / 98.31 | 2 | 3 |
7 | 13 | 17.92 | 20 | 15.30 | 349 | 107 | 3.20 / 98.42 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.26 | 320 | 806 | 4.00 / 99.22 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 23 | 15.22 | 480 | 168 | 0.17 / 91.59 | 3 | 3 |
2 | 7 | 1879.92 | 33 | 14.92 | 2844 | 1400 | 1.57 / 92.99 | 2 | 3 |
3 | 13 | 1299.88 | 20 | 15.05 | 2119 | 638 | 2.21 / 93.63 | 2 | 6 |
4 | 13 | 710.36 | 20 | 15.18 | 1368 | 415 | 2.62 / 94.04 | 2 | 4 |
5 | 13 | 269.48 | 20 | 15.28 | 751 | 230 | 2.85 / 94.27 | 2 | 3 |
6 | 13 | 86.40 | 20 | 15.31 | 464 | 142 | 2.99 / 94.41 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.26 | 321 | 808 | 3.80 / 95.22 | 2 | 3 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 23 | 15.22 | 475 | 166 | 0.17 / 87.70 | 3 | 3 |
2 | 7 | 1881.72 | 33 | 14.94 | 2849 | 1405 | 1.57 / 89.10 | 2 | 3 |
3 | 13 | 1300.48 | 20 | 15.05 | 2128 | 641 | 2.21 / 89.74 | 2 | 4 |
4 | 13 | 708.72 | 20 | 15.21 | 1354 | 412 | 2.62 / 90.15 | 2 | 4 |
5 | 13 | 261.64 | 20 | 15.30 | 738 | 226 | 2.85 / 90.38 | 2 | 4 |
6 | 13 | 96.60 | 20 | 15.31 | 470 | 144 | 2.99 / 90.52 | 2 | 3 |
7 | 13 | 25.04 | 20 | 15.31 | 356 | 109 | 3.10 / 90.63 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.27 | 313 | 789 | 3.89 / 91.42 | 3 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 23 | 15.22 | 474 | 166 | 0.17 / 83.77 | 3 | 3 |
2 | 7 | 1878.64 | 33 | 14.94 | 2854 | 1407 | 1.57 / 85.18 | 2 | 3 |
3 | 13 | 1325.40 | 20 | 15.05 | 2169 | 653 | 2.23 / 85.83 | 2 | 4 |
4 | 13 | 752.76 | 20 | 15.19 | 1422 | 432 | 2.66 / 86.26 | 2 | 5 |
5 | 13 | 215.88 | 20 | 15.32 | 663 | 203 | 2.86 / 86.47 | 2 | 3 |
6 | 13 | 113.32 | 20 | 15.31 | 501 | 153 | 3.01 / 86.62 | 2 | 3 |
7 | 13 | 25.12 | 20 | 15.30 | 367 | 112 | 3.13 / 86.73 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.27 | 316 | 796 | 3.92 / 87.53 | 2 | 7 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 23 | 15.24 | 481 | 169 | 0.17 / 79.90 | 3 | 3 |
2 | 7 | 1882.12 | 33 | 14.95 | 2852 | 1407 | 1.58 / 81.31 | 2 | 6 |
3 | 13 | 1440.84 | 20 | 15.02 | 2309 | 694 | 2.27 / 82.00 | 2 | 3 |
4 | 13 | 719.48 | 20 | 15.18 | 1371 | 416 | 2.69 / 82.42 | 2 | 4 |
5 | 13 | 285.44 | 20 | 15.29 | 774 | 237 | 2.92 / 82.65 | 2 | 4 |
6 | 13 | 82.40 | 20 | 15.32 | 460 | 141 | 3.06 / 82.80 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.28 | 322 | 812 | 3.87 / 83.61 | 2 | 6 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 23 | 15.24 | 483 | 169 | 0.17 / 76.04 | 3 | 3 |
2 | 7 | 1876.88 | 34 | 14.94 | 2861 | 1453 | 1.62 / 77.49 | 2 | 3 |
3 | 13 | 1301.60 | 20 | 15.07 | 2131 | 642 | 2.26 / 78.13 | 2 | 5 |
4 | 13 | 714.12 | 20 | 15.21 | 1371 | 417 | 2.68 / 78.55 | 2 | 4 |
5 | 13 | 274.68 | 20 | 15.31 | 755 | 231 | 2.91 / 78.78 | 2 | 3 |
6 | 13 | 81.80 | 20 | 15.31 | 449 | 137 | 3.05 / 78.92 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.28 | 322 | 812 | 3.86 / 79.73 | 2 | 3 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 23 | 15.24 | 484 | 170 | 0.17 / 72.26 | 3 | 3 |
2 | 7 | 1875.92 | 33 | 14.95 | 2843 | 1403 | 1.57 / 73.67 | 2 | 4 |
3 | 13 | 1297.36 | 20 | 15.07 | 2119 | 639 | 2.21 / 74.30 | 2 | 3 |
4 | 13 | 703.28 | 20 | 15.20 | 1346 | 409 | 2.62 / 74.71 | 2 | 5 |
5 | 13 | 259.24 | 20 | 15.31 | 728 | 223 | 2.84 / 74.94 | 2 | 3 |
6 | 13 | 89.84 | 20 | 15.31 | 460 | 141 | 2.98 / 75.08 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.28 | 314 | 792 | 3.78 / 75.87 | 2 | 7 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 23 | 15.25 | 465 | 163 | 0.16 / 68.46 | 3 | 3 |
2 | 7 | 1874.88 | 33 | 14.95 | 2838 | 1400 | 1.56 / 69.86 | 2 | 3 |
3 | 13 | 1284.80 | 20 | 15.08 | 2099 | 633 | 2.20 / 70.49 | 2 | 5 |
4 | 13 | 695.16 | 20 | 15.21 | 1339 | 407 | 2.60 / 70.90 | 2 | 3 |
5 | 13 | 251.72 | 20 | 15.33 | 721 | 221 | 2.82 / 71.12 | 2 | 3 |
6 | 13 | 137.56 | 20 | 15.31 | 539 | 165 | 2.99 / 71.29 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.28 | 320 | 807 | 3.80 / 72.09 | 2 | 3 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 23 | 15.25 | 468 | 164 | 0.16 / 64.69 | 3 | 3 |
2 | 7 | 1863.32 | 33 | 14.95 | 2825 | 1394 | 1.56 / 66.08 | 2 | 4 |
3 | 13 | 1301.84 | 20 | 15.08 | 2118 | 639 | 2.20 / 66.72 | 2 | 3 |
4 | 13 | 709.12 | 20 | 15.21 | 1358 | 413 | 2.61 / 67.13 | 2 | 6 |
5 | 13 | 258.56 | 20 | 15.32 | 734 | 225 | 2.83 / 67.36 | 2 | 3 |
6 | 13 | 85.96 | 20 | 15.32 | 455 | 139 | 2.97 / 67.50 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.29 | 318 | 802 | 3.78 / 68.30 | 2 | 7 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 23 | 15.25 | 484 | 170 | 0.17 / 60.90 | 3 | 3 |
2 | 7 | 1871.32 | 33 | 14.96 | 2839 | 1402 | 1.57 / 62.30 | 2 | 3 |
3 | 13 | 1307.84 | 20 | 15.08 | 2146 | 647 | 2.22 / 62.94 | 2 | 4 |
4 | 13 | 725.80 | 20 | 15.21 | 1377 | 419 | 2.64 / 63.36 | 2 | 3 |
5 | 13 | 205.12 | 20 | 15.32 | 647 | 198 | 2.84 / 63.56 | 2 | 3 |
6 | 13 | 129.20 | 20 | 15.31 | 522 | 160 | 3.00 / 63.72 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.29 | 317 | 800 | 3.80 / 64.52 | 2 | 3 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 23 | 15.25 | 464 | 163 | 0.16 / 57.06 | 3 | 3 |
2 | 7 | 1870.36 | 33 | 14.95 | 2852 | 1407 | 1.57 / 58.46 | 2 | 4 |
3 | 13 | 1308.64 | 20 | 15.08 | 2120 | 639 | 2.21 / 59.10 | 2 | 4 |
4 | 13 | 737.88 | 20 | 15.18 | 1392 | 423 | 2.63 / 59.53 | 2 | 4 |
5 | 13 | 296.68 | 20 | 15.30 | 787 | 241 | 2.87 / 59.77 | 2 | 4 |
6 | 13 | 100.56 | 20 | 15.32 | 482 | 148 | 3.02 / 59.91 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.29 | 322 | 812 | 3.83 / 60.73 | 2 | 5 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 23 | 15.26 | 473 | 166 | 0.17 / 53.23 | 3 | 3 |
2 | 7 | 1875.60 | 34 | 14.97 | 2863 | 1457 | 1.62 / 54.69 | 2 | 4 |
3 | 13 | 1296.16 | 20 | 15.08 | 2121 | 640 | 2.26 / 55.33 | 2 | 5 |
4 | 13 | 702.36 | 20 | 15.23 | 1351 | 412 | 2.67 / 55.74 | 2 | 6 |
5 | 13 | 255.88 | 20 | 15.32 | 727 | 223 | 2.90 / 55.96 | 2 | 3 |
6 | 13 | 85.48 | 20 | 15.32 | 450 | 138 | 3.04 / 56.10 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.30 | 314 | 793 | 3.83 / 56.89 | 2 | 5 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 23 | 15.26 | 493 | 173 | 0.17 / 49.34 | 3 | 3 |
2 | 7 | 1869.40 | 33 | 14.98 | 2848 | 1408 | 1.58 / 50.74 | 2 | 6 |
3 | 13 | 1443.72 | 20 | 15.05 | 2306 | 694 | 2.28 / 51.44 | 2 | 5 |
4 | 13 | 822.88 | 20 | 15.19 | 1510 | 459 | 2.73 / 51.90 | 2 | 4 |
5 | 13 | 254.12 | 20 | 15.33 | 726 | 223 | 2.96 / 52.12 | 2 | 3 |
6 | 13 | 91.36 | 20 | 15.34 | 465 | 143 | 3.10 / 52.26 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.31 | 318 | 803 | 3.90 / 53.07 | 3 | 3 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 23 | 15.25 | 481 | 169 | 0.17 / 45.41 | 3 | 3 |
2 | 7 | 1868.80 | 33 | 14.99 | 2842 | 1406 | 1.57 / 46.82 | 2 | 4 |
3 | 13 | 1301.80 | 20 | 15.11 | 2127 | 643 | 2.22 / 47.46 | 2 | 3 |
4 | 13 | 592.16 | 20 | 15.26 | 1210 | 369 | 2.59 / 47.83 | 2 | 4 |
5 | 13 | 207.08 | 20 | 15.33 | 653 | 200 | 2.79 / 48.03 | 2 | 3 |
6 | 13 | 108.12 | 20 | 15.34 | 497 | 152 | 2.94 / 48.18 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.31 | 329 | 831 | 3.77 / 49.01 | 2 | 5 |
8 | 14 | 0.04 | 30 | 15.28 | 325 | 149 | 3.92 / 49.16 | 3 | 5 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 23 | 15.26 | 472 | 166 | 0.17 / 41.65 | 3 | 3 |
2 | 7 | 1873.80 | 33 | 14.99 | 2826 | 1398 | 1.56 / 43.05 | 2 | 5 |
3 | 13 | 1324.80 | 20 | 15.08 | 2145 | 647 | 2.21 / 43.70 | 2 | 3 |
4 | 13 | 641.56 | 20 | 15.24 | 1269 | 387 | 2.60 / 44.09 | 2 | 4 |
5 | 13 | 229.44 | 20 | 15.31 | 688 | 211 | 2.81 / 44.30 | 2 | 3 |
6 | 13 | 83.44 | 20 | 15.32 | 455 | 139 | 2.95 / 44.44 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.30 | 320 | 808 | 3.76 / 45.24 | 2 | 4 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 23 | 15.26 | 490 | 172 | 0.17 / 37.80 | 3 | 3 |
2 | 7 | 1886.48 | 34 | 14.96 | 2849 | 1449 | 1.62 / 39.25 | 2 | 6 |
3 | 13 | 1300.56 | 20 | 15.10 | 2136 | 645 | 2.27 / 39.89 | 2 | 6 |
4 | 13 | 699.72 | 20 | 15.24 | 1348 | 411 | 2.68 / 40.30 | 2 | 6 |
5 | 13 | 270.24 | 20 | 15.33 | 757 | 232 | 2.91 / 40.54 | 2 | 4 |
6 | 13 | 93.20 | 20 | 15.33 | 471 | 144 | 3.05 / 40.68 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.31 | 320 | 808 | 3.86 / 41.49 | 2 | 8 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 23 | 15.26 | 474 | 166 | 0.17 / 33.89 | 3 | 3 |
2 | 7 | 1877.28 | 33 | 15.01 | 2871 | 1422 | 1.59 / 35.31 | 2 | 4 |
3 | 13 | 1451.64 | 20 | 15.06 | 2319 | 698 | 2.29 / 36.01 | 2 | 3 |
4 | 13 | 703.00 | 20 | 15.24 | 1345 | 410 | 2.70 / 36.42 | 2 | 4 |
5 | 13 | 273.08 | 20 | 15.33 | 759 | 233 | 2.93 / 36.66 | 2 | 4 |
6 | 13 | 94.68 | 20 | 15.33 | 474 | 145 | 3.07 / 36.80 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.30 | 327 | 826 | 3.90 / 37.63 | 2 | 4 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 23 | 15.25 | 474 | 166 | 0.17 / 30.03 | 3 | 3 |
2 | 7 | 1872.36 | 33 | 15.00 | 2842 | 1407 | 1.57 / 31.44 | 2 | 3 |
3 | 13 | 1428.92 | 20 | 15.08 | 2280 | 688 | 2.26 / 32.12 | 2 | 5 |
4 | 13 | 700.60 | 20 | 15.25 | 1351 | 412 | 2.67 / 32.54 | 2 | 6 |
5 | 13 | 263.76 | 20 | 15.35 | 745 | 229 | 2.90 / 32.76 | 2 | 3 |
6 | 13 | 87.52 | 20 | 15.34 | 464 | 142 | 3.04 / 32.91 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.32 | 324 | 819 | 3.86 / 33.73 | 2 | 6 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 22 | 15.27 | 480 | 161 | 0.16 / 26.17 | 3 | 3 |
2 | 10 | 1012.48 | 2 | 15.32 | 1772 | 54 | 0.22 / 26.22 | 2 | 3 |
3 | 3 | 974.40 | -1 | 15.71 | 1 | 0 | 0.05 / 26.22 | 2 | 3 |
4 | 7 | 1872.56 | 33 | 15.00 | 2824 | 1398 | 1.61 / 27.62 | 2 | 4 |
5 | 13 | 1294.44 | 20 | 15.12 | 2100 | 635 | 2.25 / 28.26 | 2 | 4 |
6 | 13 | 714.88 | 20 | 15.23 | 1361 | 415 | 2.66 / 28.67 | 2 | 4 |
7 | 13 | 268.64 | 20 | 15.34 | 748 | 229 | 2.89 / 28.90 | 2 | 3 |
8 | 13 | 89.56 | 20 | 15.33 | 465 | 143 | 3.04 / 29.04 | 2 | 3 |
9 | 8 | 0.24 | 165 | 15.31 | 325 | 821 | 3.86 / 29.86 | 2 | 6 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 22 | 15.30 | 469 | 158 | 0.16 / 22.45 | 3 | 3 |
2 | 7 | 1868.24 | 38 | 14.97 | 2828 | 1609 | 1.77 / 24.06 | 2 | 3 |
3 | 13 | 1032.04 | 18 | 15.17 | 1772 | 484 | 2.25 / 24.55 | 2 | 5 |
4 | 13 | 613.76 | 18 | 15.26 | 1230 | 338 | 2.59 / 24.88 | 2 | 4 |
5 | 13 | 192.92 | 18 | 15.35 | 631 | 174 | 2.76 / 25.06 | 2 | 3 |
6 | 13 | 105.48 | 18 | 15.35 | 492 | 136 | 2.90 / 25.19 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.32 | 322 | 814 | 3.71 / 26.01 | 2 | 3 |
Average= | 3.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 23 | 15.31 | 457 | 161 | 0.16 / 19.22 | 3 | 3 |
2 | 3 | 960.84 | -1 | 15.68 | 0 | 0 | 0.00 / 19.22 | 3 | 3 |
3 | 7 | 1219.96 | 38 | 15.26 | 1993 | 1156 | 1.32 / 20.37 | 2 | 4 |
4 | 13 | 970.52 | 18 | 15.29 | 1695 | 466 | 1.78 / 20.84 | 2 | 5 |
5 | 13 | 430.44 | 18 | 15.39 | 978 | 271 | 2.05 / 21.11 | 2 | 4 |
6 | 13 | 165.96 | 18 | 15.42 | 583 | 162 | 2.22 / 21.27 | 2 | 3 |
7 | 13 | 91.12 | 18 | 15.40 | 460 | 128 | 2.34 / 21.40 | 2 | 3 |
8 | 13 | 22.96 | 18 | 15.40 | 353 | 98 | 2.44 / 21.50 | 2 | 3 |
9 | 8 | 0.00 | 165 | 15.36 | 314 | 796 | 3.24 / 22.29 | 2 | 5 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 28 | 15.27 | 458 | 196 | 0.20 / 16.12 | 3 | 3 |
2 | 3 | 763.76 | -7 | 15.68 | 1 | 0 | 0.00 / 16.12 | 3 | 3 |
3 | 7 | 1208.32 | 38 | 15.26 | 1976 | 1146 | 1.34 / 17.26 | 2 | 5 |
4 | 13 | 957.40 | 18 | 15.29 | 1671 | 460 | 1.80 / 17.72 | 2 | 4 |
5 | 13 | 416.64 | 18 | 15.38 | 945 | 262 | 2.06 / 17.98 | 2 | 4 |
6 | 13 | 153.44 | 18 | 15.41 | 557 | 155 | 2.22 / 18.14 | 2 | 3 |
7 | 13 | 82.44 | 18 | 15.41 | 445 | 123 | 2.34 / 18.26 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.36 | 314 | 796 | 3.14 / 19.06 | 2 | 3 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 21 | 15.29 | 462 | 148 | 0.15 / 12.34 | 3 | 3 |
2 | 3 | 1024.24 | 1 | 15.36 | 1839 | 28 | 0.18 / 12.37 | 2 | 4 |
3 | 7 | 1416.64 | 74 | 15.04 | 2226 | 2477 | 2.65 / 14.85 | 2 | 6 |
4 | 13 | 187.92 | 18 | 15.37 | 607 | 168 | 2.82 / 15.02 | 2 | 3 |
5 | 13 | 102.16 | 18 | 15.38 | 471 | 130 | 2.95 / 15.15 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.34 | 306 | 775 | 3.73 / 15.92 | 2 | 4 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 19 | 15.27 | 448 | 130 | 0.13 / 8.75 | 3 | 3 |
2 | 10 | 1046.68 | 3 | 15.31 | 1851 | 85 | 0.21 / 8.83 | 2 | 3 |
3 | 7 | 1259.92 | 74 | 15.12 | 2036 | 2278 | 2.49 / 11.11 | 2 | 5 |
4 | 13 | 188.00 | 18 | 15.39 | 608 | 168 | 2.66 / 11.28 | 2 | 3 |
5 | 13 | 105.92 | 18 | 15.38 | 483 | 134 | 2.80 / 11.41 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.35 | 309 | 783 | 3.58 / 12.19 | 2 | 4 |
Average= | 3.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 31 | 15.29 | 471 | 223 | 0.22 / 4.79 | 3 | 3 |
2 | 3 | 674.04 | -6 | 15.71 | 1 | 0 | 0.00 / 4.79 | 3 | 3 |
3 | 3 | 864.32 | -3 | 15.75 | 1 | 0 | 0.00 / 4.79 | 3 | 3 |
4 | 7 | 1378.00 | 74 | 15.07 | 2173 | 2423 | 2.65 / 7.21 | 2 | 4 |
5 | 13 | 160.88 | 18 | 15.38 | 558 | 154 | 2.80 / 7.36 | 2 | 3 |
6 | 13 | 98.56 | 18 | 15.37 | 467 | 129 | 2.93 / 7.49 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.34 | 305 | 772 | 3.70 / 8.27 | 2 | 6 |
8 | 14 | 0.04 | 75 | 15.30 | 305 | 350 | 4.05 / 8.62 | 2 | 5 |
Average= | 2.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 26 | 15.47 | 424 | 171 | 0.17 / 1.79 | 3 | 3 |
2 | 3 | 820.60 | -3 | 15.71 | 0 | 0 | 0.00 / 1.79 | 3 | 3 |
3 | 3 | 916.36 | -2 | 15.75 | 1 | 0 | 0.00 / 1.79 | 3 | 3 |
4 | 7 | 993.80 | 74 | 15.20 | 1675 | 1884 | 2.05 / 3.68 | 2 | 3 |
5 | 13 | 56.96 | 18 | 15.39 | 399 | 111 | 2.17 / 3.79 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.35 | 307 | 778 | 2.94 / 4.56 | 2 | 5 |
Average= | 2.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 78.28 | 25 | 15.65 | 395 | 155 | 0.15 / 0.15 | 3 | 3 |
2 | 7 | 96.68 | 74 | 15.61 | 426 | 492 | 0.65 / 0.65 | 3 | 3 |
3 | 8 | 0.16 | 240 | 15.56 | 261 | 975 | 1.62 / 1.62 | 3 | 5 |
Average= | 1.62 (KJ/cycle) |