SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 32 | 15.25 | 424 | 207 | 0.21 / 63.20 | 2 | 2 |
2 | 3 | 1017.76 | 1 | 15.31 | 1813 | 28 | 0.23 / 63.22 | 2 | 2 |
3 | 7 | 1985.52 | 39 | 14.87 | 2983 | 1730 | 1.96 / 64.95 | 2 | 2 |
4 | 13 | 1561.12 | 18 | 14.97 | 2454 | 661 | 2.63 / 65.62 | 2 | 2 |
5 | 13 | 971.28 | 18 | 15.10 | 1676 | 456 | 3.08 / 66.07 | 2 | 2 |
6 | 13 | 264.96 | 18 | 15.30 | 703 | 194 | 3.27 / 66.26 | 2 | 2 |
7 | 13 | 154.00 | 18 | 15.30 | 517 | 142 | 3.42 / 66.41 | 2 | 3 |
8 | 13 | 80.96 | 18 | 15.31 | 403 | 111 | 3.53 / 66.52 | 2 | 2 |
9 | 8 | -0.08 | 165 | 15.27 | 269 | 678 | 4.21 / 67.20 | 2 | 6 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 31 | 15.26 | 427 | 202 | 0.20 / 59.17 | 2 | 2 |
2 | 3 | 1016.52 | 1 | 15.31 | 1806 | 28 | 0.23 / 59.20 | 2 | 2 |
3 | 7 | 1837.88 | 38 | 14.92 | 2794 | 1584 | 1.81 / 60.78 | 2 | 2 |
4 | 13 | 1556.40 | 18 | 14.98 | 2442 | 658 | 2.47 / 61.44 | 2 | 2 |
5 | 13 | 954.20 | 18 | 15.12 | 1657 | 451 | 2.92 / 61.89 | 2 | 2 |
6 | 13 | 256.88 | 18 | 15.31 | 688 | 190 | 3.11 / 62.08 | 2 | 2 |
7 | 13 | 142.84 | 18 | 15.31 | 504 | 139 | 3.25 / 62.22 | 2 | 2 |
8 | 13 | 45.92 | 18 | 15.31 | 343 | 95 | 3.35 / 62.31 | 2 | 2 |
9 | 8 | 0.00 | 165 | 15.28 | 268 | 676 | 4.02 / 62.99 | 2 | 6 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 31 | 15.26 | 427 | 202 | 0.20 / 55.25 | 2 | 2 |
2 | 3 | 1023.36 | 1 | 15.33 | 1833 | 28 | 0.23 / 55.28 | 2 | 2 |
3 | 7 | 1825.92 | 38 | 14.93 | 2771 | 1572 | 1.80 / 56.85 | 2 | 2 |
4 | 13 | 1423.44 | 18 | 15.02 | 2273 | 615 | 2.42 / 57.46 | 2 | 2 |
5 | 13 | 852.92 | 18 | 15.15 | 1518 | 414 | 2.83 / 57.88 | 2 | 2 |
6 | 13 | 274.68 | 18 | 15.31 | 717 | 198 | 3.03 / 58.08 | 2 | 2 |
7 | 13 | 121.16 | 18 | 15.30 | 467 | 129 | 3.16 / 58.20 | 2 | 2 |
8 | 13 | 34.36 | 18 | 15.32 | 328 | 90 | 3.25 / 58.29 | 2 | 2 |
9 | 8 | 0.00 | 165 | 15.29 | 267 | 674 | 3.92 / 58.97 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 30 | 15.26 | 424 | 194 | 0.19 / 51.19 | 2 | 2 |
2 | 3 | 1017.16 | 1 | 15.34 | 1831 | 28 | 0.22 / 51.22 | 2 | 2 |
3 | 7 | 2013.64 | 38 | 14.89 | 3008 | 1702 | 1.92 / 52.92 | 2 | 2 |
4 | 13 | 1440.44 | 18 | 15.02 | 2294 | 620 | 2.54 / 53.54 | 2 | 2 |
5 | 13 | 851.76 | 18 | 15.15 | 1515 | 413 | 2.96 / 53.95 | 2 | 2 |
6 | 13 | 284.60 | 18 | 15.31 | 729 | 201 | 3.16 / 54.15 | 2 | 2 |
7 | 13 | 123.92 | 18 | 15.32 | 466 | 129 | 3.29 / 54.28 | 2 | 2 |
8 | 13 | 35.24 | 18 | 15.32 | 327 | 90 | 3.38 / 54.37 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.29 | 267 | 674 | 4.05 / 55.05 | 2 | 3 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 30 | 15.26 | 426 | 195 | 0.20 / 47.14 | 2 | 2 |
2 | 7 | 2010.68 | 38 | 14.89 | 3010 | 1703 | 1.90 / 48.84 | 2 | 2 |
3 | 13 | 1440.56 | 18 | 15.01 | 2294 | 620 | 2.52 / 49.46 | 2 | 2 |
4 | 13 | 878.04 | 18 | 15.14 | 1560 | 425 | 2.94 / 49.89 | 2 | 2 |
5 | 13 | 306.44 | 18 | 15.30 | 763 | 210 | 3.15 / 50.10 | 2 | 2 |
6 | 13 | 143.32 | 18 | 15.30 | 497 | 137 | 3.29 / 50.24 | 2 | 2 |
7 | 13 | 40.48 | 18 | 15.32 | 331 | 91 | 3.38 / 50.33 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.29 | 265 | 669 | 4.05 / 51.00 | 2 | 4 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 30 | 15.26 | 422 | 193 | 0.19 / 43.11 | 2 | 2 |
2 | 7 | 2011.16 | 38 | 14.89 | 3007 | 1701 | 1.89 / 44.81 | 2 | 2 |
3 | 13 | 1443.76 | 18 | 15.02 | 2303 | 623 | 2.52 / 45.43 | 2 | 2 |
4 | 13 | 866.92 | 18 | 15.14 | 1538 | 419 | 2.94 / 45.85 | 2 | 2 |
5 | 13 | 287.00 | 18 | 15.31 | 734 | 202 | 3.14 / 46.05 | 2 | 2 |
6 | 13 | 130.32 | 18 | 15.31 | 477 | 131 | 3.27 / 46.19 | 2 | 2 |
7 | 13 | 17.00 | 18 | 15.32 | 299 | 82 | 3.35 / 46.27 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.29 | 269 | 679 | 4.03 / 46.95 | 2 | 3 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 30 | 15.25 | 429 | 196 | 0.20 / 38.98 | 2 | 2 |
2 | 7 | 2003.92 | 39 | 14.89 | 2993 | 1738 | 1.93 / 40.71 | 2 | 2 |
3 | 13 | 1456.96 | 18 | 15.02 | 2319 | 627 | 2.56 / 41.34 | 2 | 2 |
4 | 13 | 1020.12 | 18 | 15.09 | 1736 | 472 | 3.03 / 41.81 | 2 | 2 |
5 | 13 | 242.84 | 18 | 15.31 | 670 | 185 | 3.22 / 42.00 | 2 | 2 |
6 | 13 | 158.88 | 18 | 15.29 | 528 | 145 | 3.36 / 42.14 | 2 | 2 |
7 | 13 | 35.36 | 18 | 15.32 | 334 | 92 | 3.45 / 42.23 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.29 | 270 | 681 | 4.14 / 42.92 | 2 | 3 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 29 | 15.25 | 425 | 188 | 0.19 / 34.81 | 2 | 2 |
2 | 10 | 1022.20 | 2 | 15.29 | 1794 | 55 | 0.24 / 34.86 | 2 | 2 |
3 | 7 | 2005.48 | 38 | 14.90 | 2997 | 1697 | 1.94 / 36.56 | 2 | 2 |
4 | 13 | 1570.28 | 18 | 15.00 | 2461 | 664 | 2.60 / 37.22 | 2 | 2 |
5 | 13 | 962.40 | 18 | 15.12 | 1667 | 454 | 3.06 / 37.68 | 2 | 2 |
6 | 13 | 242.92 | 18 | 15.32 | 670 | 185 | 3.24 / 37.86 | 2 | 2 |
7 | 13 | 153.40 | 18 | 15.32 | 515 | 142 | 3.38 / 38.01 | 2 | 2 |
8 | 13 | 39.28 | 18 | 15.32 | 336 | 93 | 3.48 / 38.10 | 2 | 2 |
9 | 8 | 0.08 | 165 | 15.29 | 270 | 681 | 4.16 / 38.78 | 2 | 7 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 29 | 15.25 | 416 | 184 | 0.18 / 30.67 | 2 | 2 |
2 | 10 | 1008.36 | 2 | 15.30 | 1769 | 54 | 0.24 / 30.72 | 2 | 2 |
3 | 3 | 944.16 | -1 | 15.68 | 0 | 0 | 0.05 / 30.72 | 2 | 2 |
4 | 7 | 2006.60 | 38 | 14.91 | 3007 | 1704 | 1.94 / 32.43 | 2 | 2 |
5 | 13 | 1566.36 | 18 | 15.00 | 2452 | 662 | 2.60 / 33.09 | 2 | 2 |
6 | 13 | 841.16 | 18 | 15.16 | 1506 | 411 | 3.01 / 33.50 | 2 | 2 |
7 | 13 | 275.84 | 18 | 15.33 | 718 | 198 | 3.21 / 33.70 | 2 | 2 |
8 | 13 | 151.16 | 18 | 15.32 | 525 | 145 | 3.36 / 33.84 | 2 | 3 |
9 | 13 | 19.16 | 18 | 15.34 | 311 | 86 | 3.44 / 33.93 | 2 | 3 |
10 | 8 | 0.08 | 165 | 15.29 | 274 | 691 | 4.13 / 34.62 | 2 | 4 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 29 | 15.29 | 425 | 188 | 0.19 / 26.72 | 2 | 2 |
2 | 3 | 1019.84 | 1 | 15.35 | 1806 | 28 | 0.22 / 26.75 | 2 | 2 |
3 | 7 | 2012.80 | 38 | 14.91 | 3008 | 1704 | 1.92 / 28.45 | 2 | 2 |
4 | 13 | 1318.72 | 18 | 15.07 | 2137 | 580 | 2.50 / 29.03 | 2 | 2 |
5 | 13 | 767.20 | 18 | 15.18 | 1406 | 384 | 2.88 / 29.42 | 2 | 2 |
6 | 13 | 198.56 | 18 | 15.34 | 606 | 167 | 3.05 / 29.58 | 2 | 2 |
7 | 13 | 141.84 | 18 | 15.33 | 502 | 139 | 3.19 / 29.72 | 2 | 2 |
8 | 13 | 17.64 | 18 | 15.33 | 300 | 83 | 3.27 / 29.80 | 2 | 2 |
9 | 8 | 0.00 | 165 | 15.30 | 270 | 682 | 3.95 / 30.49 | 2 | 7 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 29 | 15.28 | 428 | 190 | 0.19 / 22.81 | 2 | 2 |
2 | 3 | 1024.56 | 1 | 15.34 | 1816 | 28 | 0.22 / 22.84 | 2 | 2 |
3 | 7 | 2002.76 | 38 | 14.93 | 2994 | 1699 | 1.92 / 24.54 | 2 | 2 |
4 | 13 | 1294.16 | 18 | 15.08 | 2102 | 571 | 2.49 / 25.11 | 2 | 2 |
5 | 13 | 740.12 | 18 | 15.21 | 1369 | 375 | 2.86 / 25.48 | 2 | 2 |
6 | 13 | 199.76 | 18 | 15.34 | 593 | 164 | 3.03 / 25.65 | 2 | 2 |
7 | 13 | 138.24 | 18 | 15.33 | 485 | 134 | 3.16 / 25.78 | 2 | 2 |
8 | 13 | 33.56 | 18 | 15.33 | 315 | 87 | 3.25 / 25.87 | 2 | 2 |
9 | 8 | 0.12 | 165 | 15.31 | 263 | 664 | 3.91 / 26.53 | 2 | 3 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 28 | 15.28 | 425 | 182 | 0.18 / 18.96 | 2 | 2 |
2 | 10 | 1016.32 | 2 | 15.29 | 1763 | 54 | 0.24 / 19.01 | 2 | 2 |
3 | 3 | 965.88 | -1 | 15.69 | 0 | 0 | 0.05 / 19.01 | 2 | 2 |
4 | 7 | 2002.40 | 38 | 14.93 | 2988 | 1695 | 1.93 / 20.71 | 2 | 2 |
5 | 13 | 1289.80 | 18 | 15.09 | 2096 | 569 | 2.50 / 21.28 | 2 | 2 |
6 | 13 | 734.92 | 18 | 15.21 | 1362 | 373 | 2.87 / 21.65 | 2 | 2 |
7 | 13 | 195.32 | 18 | 15.35 | 594 | 164 | 3.04 / 21.81 | 2 | 2 |
8 | 13 | 133.36 | 18 | 15.34 | 480 | 133 | 3.17 / 21.95 | 2 | 2 |
9 | 8 | 0.04 | 165 | 15.31 | 267 | 674 | 3.84 / 22.62 | 2 | 3 |
Average= | 3.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 29 | 15.28 | 412 | 183 | 0.18 / 15.03 | 2 | 2 |
2 | 3 | 956.08 | -1 | 15.69 | 0 | 0 | 0.00 / 15.03 | 2 | 2 |
3 | 7 | 2010.12 | 38 | 14.93 | 2992 | 1697 | 1.88 / 16.72 | 2 | 2 |
4 | 13 | 1428.76 | 18 | 15.05 | 2264 | 613 | 2.49 / 17.34 | 2 | 2 |
5 | 13 | 860.28 | 18 | 15.18 | 1520 | 415 | 2.91 / 17.75 | 2 | 2 |
6 | 13 | 268.92 | 18 | 15.33 | 701 | 193 | 3.10 / 17.95 | 2 | 2 |
7 | 13 | 143.40 | 18 | 15.33 | 505 | 139 | 3.24 / 18.08 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.31 | 274 | 692 | 3.93 / 18.78 | 2 | 6 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 27 | 15.27 | 411 | 169 | 0.17 / 11.61 | 2 | 2 |
2 | 7 | 1523.68 | 38 | 15.11 | 2362 | 1356 | 1.53 / 12.97 | 2 | 2 |
3 | 13 | 1268.60 | 18 | 15.14 | 2046 | 558 | 2.08 / 13.53 | 2 | 2 |
4 | 13 | 669.56 | 18 | 15.25 | 1262 | 346 | 2.43 / 13.87 | 2 | 2 |
5 | 13 | 197.84 | 18 | 15.36 | 596 | 165 | 2.59 / 14.04 | 2 | 2 |
6 | 13 | 123.68 | 18 | 15.34 | 464 | 128 | 2.72 / 14.17 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.32 | 268 | 677 | 3.40 / 14.84 | 2 | 5 |
Average= | 2.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 27 | 15.28 | 421 | 174 | 0.17 / 8.22 | 2 | 2 |
2 | 7 | 1514.68 | 38 | 15.11 | 2352 | 1350 | 1.52 / 9.57 | 2 | 2 |
3 | 13 | 1251.48 | 18 | 15.14 | 2019 | 550 | 2.07 / 10.12 | 2 | 2 |
4 | 13 | 673.72 | 18 | 15.25 | 1266 | 348 | 2.42 / 10.47 | 2 | 2 |
5 | 13 | 209.44 | 18 | 15.35 | 609 | 168 | 2.59 / 10.64 | 2 | 2 |
6 | 13 | 128.44 | 18 | 15.34 | 472 | 130 | 2.72 / 10.77 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.32 | 266 | 672 | 3.39 / 11.44 | 2 | 6 |
Average= | 2.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 31 | 15.32 | 421 | 200 | 0.20 / 4.40 | 2 | 2 |
2 | 3 | 817.24 | -3 | 15.71 | 0 | 0 | 0.00 / 4.40 | 2 | 2 |
3 | 3 | 972.32 | -1 | 15.72 | 0 | 0 | 0.00 / 4.40 | 2 | 2 |
4 | 7 | 1525.28 | 75 | 15.01 | 2350 | 2646 | 2.85 / 7.05 | 2 | 2 |
5 | 13 | 256.76 | 18 | 15.35 | 678 | 187 | 3.03 / 7.23 | 2 | 2 |
6 | 13 | 147.56 | 18 | 15.34 | 503 | 139 | 3.17 / 7.37 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.32 | 268 | 677 | 3.85 / 8.05 | 2 | 2 |
Average= | 2.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 26 | 15.51 | 374 | 151 | 0.15 / 1.55 | 2 | 3 |
2 | 7 | 995.04 | 74 | 15.20 | 1656 | 1863 | 2.01 / 3.42 | 2 | 2 |
3 | 13 | 48.04 | 18 | 15.40 | 354 | 98 | 2.11 / 3.51 | 2 | 2 |
4 | 8 | 0.00 | 165 | 15.36 | 271 | 687 | 2.80 / 4.20 | 2 | 3 |
Average= | 2.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 26 | 15.66 | 379 | 154 | 0.15 / 0.15 | 2 | 3 |
2 | 7 | 124.72 | 74 | 15.62 | 401 | 464 | 0.62 / 0.62 | 2 | 3 |
3 | 8 | -0.00 | 240 | 15.57 | 210 | 785 | 1.40 / 1.40 | 2 | 7 |
Average= | 1.40 (KJ/cycle) |