SIO Argo Site:
Pump Diagnostics Page   



Serial= 8898 WMO= 5906152

Return

←PreviousNext→

Cycle 156 GMT 13/11/2024 16: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 32 14.99 450 216 0.22 / 570.06 2 2
2 7 1978.96 30 14.79 2896 1285 1.50 / 571.34 2 6
3 13 1718.92 18 14.77 2552 678 2.18 / 572.02 2 3
4 13 1154.44 18 14.83 1843 492 2.67 / 572.51 2 4
5 13 573.92 18 14.94 1069 287 2.96 / 572.80 2 3
6 8 0.20 165 15.03 261 647 3.61 / 573.45 2 2
7 14 0.20 30 15.01 265 119 3.73 / 573.57 2 3
Average= 3.65
(KJ/cycle)

Cycle 155 GMT 3/11/2024 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 32 15.00 442 212 0.21 / 566.29 2 2
2 7 2006.88 30 14.81 2912 1294 1.51 / 567.58 2 4
3 13 1617.24 18 14.80 2440 650 2.16 / 568.23 2 3
4 13 1197.80 18 14.82 1902 507 2.66 / 568.74 2 4
5 13 636.08 18 14.93 1155 310 2.97 / 569.05 2 4
6 8 -0.16 165 15.04 270 670 3.64 / 569.72 2 2
7 14 -0.16 30 15.02 270 122 3.77 / 569.84 2 10
Average= 3.65
(KJ/cycle)

Cycle 154 GMT 24/10/2024 23: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 32 15.02 437 210 0.21 / 562.67 2 3
2 7 2007.88 30 14.82 2919 1298 1.51 / 563.97 2 3
3 13 1624.36 18 14.80 2450 653 2.16 / 564.62 2 5
4 13 1210.12 18 14.82 1920 512 2.67 / 565.13 2 5
5 13 604.28 18 14.94 1118 301 2.97 / 565.43 2 5
6 8 -0.04 165 15.05 259 643 3.62 / 566.07 2 2
Average= 3.65
(KJ/cycle)

Cycle 153 GMT 15/10/2024 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 32 15.03 417 201 0.20 / 559.07 2 3
2 7 2008.32 30 14.82 2925 1300 1.50 / 560.37 2 3
3 13 1600.56 18 14.83 2409 643 2.14 / 561.01 2 6
4 13 1189.68 18 14.84 1889 505 2.65 / 561.52 2 3
5 13 590.28 18 14.95 1096 295 2.94 / 561.81 2 4
6 8 0.40 165 15.07 260 647 3.59 / 562.46 2 2
Average= 3.65
(KJ/cycle)

Cycle 152 GMT 5/10/2024 8:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 32 15.02 430 207 0.21 / 555.49 2 2
2 7 2011.08 30 14.82 2920 1298 1.50 / 556.78 2 3
3 13 1749.96 18 14.79 2595 691 2.20 / 557.48 2 6
4 13 1155.92 18 14.85 1837 491 2.69 / 557.97 2 5
5 13 472.04 18 14.99 939 253 2.94 / 558.22 2 4
6 8 -0.12 165 15.06 261 649 3.59 / 558.87 2 2
Average= 3.65
(KJ/cycle)

Cycle 151 GMT 25/ 9/2024 13:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 32 15.01 442 212 0.21 / 551.76 2 2
2 7 2006.96 30 14.82 2930 1303 1.51 / 553.06 2 5
3 13 1593.84 18 14.82 2401 640 2.16 / 553.70 2 5
4 13 1183.36 18 14.85 1884 504 2.66 / 554.21 2 4
5 13 593.40 18 14.95 1103 297 2.96 / 554.50 2 3
6 8 0.12 165 15.06 264 656 3.61 / 555.16 2 2
7 14 0.12 30 15.04 264 119 3.73 / 555.28 2 3
Average= 3.65
(KJ/cycle)

Cycle 150 GMT 15/ 9/2024 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 32 15.00 438 210 0.21 / 548.02 2 2
2 7 2007.88 30 14.82 2924 1300 1.51 / 549.32 2 5
3 13 1734.16 18 14.80 2594 691 2.20 / 550.01 2 4
4 13 1154.32 18 14.85 1838 491 2.69 / 550.50 2 3
5 13 572.88 18 14.96 1075 289 2.98 / 550.79 2 4
6 8 0.08 165 15.07 259 644 3.63 / 551.43 2 2
7 14 0.08 30 15.05 258 116 3.74 / 551.55 2 2
Average= 3.65
(KJ/cycle)

Cycle 149 GMT 5/ 9/2024 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 32 15.02 434 209 0.21 / 544.22 2 3
2 7 2006.20 31 14.81 2910 1336 1.54 / 545.56 2 2
3 13 1738.20 18 14.78 2575 685 2.23 / 546.25 2 6
4 13 1164.52 18 14.83 1863 497 2.73 / 546.74 2 3
5 13 583.72 18 14.93 1091 293 3.02 / 547.04 2 3
6 8 0.04 165 15.05 262 651 3.67 / 547.69 2 3
7 14 0.04 30 15.03 264 119 3.79 / 547.81 2 2
Average= 3.65
(KJ/cycle)

Cycle 148 GMT 27/ 8/2024 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 32 15.01 450 216 0.22 / 540.41 2 2
2 7 2007.00 31 14.82 2918 1341 1.56 / 541.76 2 4
3 13 1737.96 18 14.78 2594 690 2.25 / 542.45 2 5
4 13 1172.92 18 14.84 1869 499 2.75 / 542.94 2 5
5 13 607.40 18 14.95 1123 302 3.05 / 543.25 2 4
6 8 0.12 165 15.06 262 651 3.70 / 543.90 2 3
7 14 0.12 30 15.04 262 118 3.82 / 544.02 2 2
Average= 3.65
(KJ/cycle)

Cycle 147 GMT 17/ 8/2024 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 31 15.00 451 210 0.21 / 536.65 2 2
2 7 2011.28 30 14.82 2913 1295 1.50 / 537.94 2 4
3 13 1737.40 18 14.79 2582 687 2.19 / 538.63 2 4
4 13 1159.92 18 14.84 1856 496 2.69 / 539.13 2 4
5 13 592.48 18 14.95 1106 298 2.99 / 539.43 2 4
6 8 0.00 165 15.06 263 654 3.64 / 540.08 2 2
7 14 0.00 30 15.05 265 120 3.76 / 540.20 2 2
Average= 3.65
(KJ/cycle)

Cycle 146 GMT 7/ 8/2024 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 32 15.01 452 217 0.22 / 532.81 2 3
2 7 2009.40 30 14.82 2919 1298 1.51 / 534.11 2 5
3 13 1733.52 18 14.79 2578 686 2.20 / 534.80 2 6
4 13 1151.96 18 14.86 1836 491 2.69 / 535.29 2 4
5 13 572.72 18 14.97 1079 291 2.98 / 535.58 2 4
6 13 24.28 18 15.09 299 81 3.06 / 535.66 2 2
7 8 -0.12 165 15.06 265 658 3.72 / 536.32 2 2
8 14 -0.12 30 15.05 265 120 3.84 / 536.44 2 2
Average= 3.65
(KJ/cycle)

Cycle 145 GMT 28/ 7/2024 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 32 15.01 445 214 0.21 / 529.10 2 3
2 7 2012.64 30 14.83 2916 1297 1.51 / 530.39 2 6
3 13 1619.12 18 14.82 2435 650 2.16 / 531.04 2 5
4 13 1065.48 18 14.87 1731 463 2.62 / 531.51 2 4
5 13 632.44 18 14.94 1157 311 2.94 / 531.82 2 4
6 8 0.28 165 15.06 265 658 3.59 / 532.48 2 5
7 14 0.28 30 15.04 267 120 3.71 / 532.60 2 2
Average= 3.65
(KJ/cycle)

Cycle 144 GMT 19/ 7/2024 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 32 15.01 432 207 0.21 / 525.51 2 3
2 7 2009.44 30 14.81 2936 1304 1.51 / 526.81 2 5
3 13 1613.32 18 14.81 2442 651 2.16 / 527.46 2 5
4 13 1206.20 18 14.83 1917 512 2.67 / 527.97 2 6
5 13 463.04 18 14.99 934 252 2.93 / 528.22 2 4
6 8 -0.20 165 15.06 265 658 3.59 / 528.88 2 2
Average= 3.65
(KJ/cycle)

Cycle 143 GMT 9/ 7/2024 5:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 32 15.00 446 214 0.21 / 521.82 2 3
2 7 2009.04 31 14.82 2918 1341 1.55 / 523.16 2 7
3 13 1744.72 18 14.80 2589 690 2.24 / 523.85 2 3
4 13 1163.56 18 14.85 1855 496 2.74 / 524.35 2 4
5 13 591.12 18 14.94 1102 296 3.04 / 524.64 2 3
6 8 0.32 165 15.06 263 654 3.69 / 525.30 2 3
Average= 3.65
(KJ/cycle)

Cycle 142 GMT 29/ 6/2024 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 32 15.01 431 207 0.21 / 517.99 2 2
2 7 2013.88 30 14.84 2930 1304 1.51 / 519.30 2 7
3 13 1755.16 18 14.79 2615 696 2.21 / 519.99 2 7
4 13 1308.92 18 14.83 2047 546 2.75 / 520.54 2 4
5 13 580.12 18 14.96 1092 294 3.05 / 520.83 2 4
6 8 -0.24 165 15.06 264 656 3.70 / 521.49 2 3
7 14 -0.24 30 15.05 266 120 3.82 / 521.61 2 2
Average= 3.65
(KJ/cycle)

Cycle 141 GMT 19/ 6/2024 15:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 32 15.01 420 202 0.20 / 514.25 2 2
2 7 2009.92 30 14.84 2925 1302 1.50 / 515.55 2 3
3 13 1621.52 18 14.81 2452 654 2.16 / 516.21 2 4
4 13 1192.24 18 14.84 1897 507 2.66 / 516.71 2 4
5 13 609.00 18 14.95 1123 302 2.97 / 517.02 2 3
6 8 -0.04 165 15.06 262 651 3.62 / 517.67 2 3
7 14 -0.04 30 15.04 260 117 3.73 / 517.78 2 6
Average= 3.65
(KJ/cycle)

Cycle 140 GMT 9/ 6/2024 20:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 30 15.03 432 195 0.19 / 510.52 2 3
2 3 1051.04 1 15.04 1750 26 0.22 / 510.55 2 4
3 7 2008.36 30 14.82 2920 1298 1.52 / 511.85 2 3
4 13 1729.84 18 14.79 2594 691 2.21 / 512.54 2 4
5 13 1147.84 18 14.86 1840 492 2.70 / 513.03 2 4
6 13 473.84 18 14.99 939 253 2.96 / 513.29 2 4
7 8 0.12 165 15.06 260 646 3.60 / 513.93 2 2
8 14 0.12 30 15.04 260 117 3.72 / 514.05 3 2
Average= 3.65
(KJ/cycle)

Cycle 139 GMT 31/ 5/2024 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 30 15.03 447 202 0.20 / 506.77 2 2
2 7 2003.96 30 14.83 2925 1301 1.50 / 508.07 2 3
3 13 1602.36 18 14.82 2430 648 2.15 / 508.72 2 5
4 13 1188.64 18 14.84 1895 506 2.66 / 509.22 2 4
5 13 468.44 18 15.00 936 253 2.91 / 509.48 2 3
6 13 36.52 18 15.10 321 87 3.00 / 509.56 2 2
7 8 1.12 165 15.07 261 649 3.65 / 510.21 2 3
8 14 1.12 30 15.04 259 117 3.76 / 510.33 2 4
Average= 3.65
(KJ/cycle)

Cycle 138 GMT 21/ 5/2024 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 30 15.04 440 199 0.20 / 503.15 2 3
2 3 1016.28 1 15.08 1724 26 0.22 / 503.17 2 3
3 7 2008.20 30 14.80 2926 1299 1.52 / 504.47 2 3
4 13 1736.84 18 14.78 2611 695 2.22 / 505.17 2 6
5 13 1138.88 18 14.85 1840 492 2.71 / 505.66 2 5
6 13 437.32 18 14.99 909 245 2.96 / 505.90 2 4
7 8 -0.04 165 15.07 267 664 3.62 / 506.57 2 2
Average= 3.64
(KJ/cycle)

Cycle 137 GMT 11/ 5/2024 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 30 15.02 440 198 0.20 / 499.53 2 2
2 7 2010.68 30 14.82 2929 1302 1.50 / 500.83 2 3
3 13 1740.16 18 14.80 2601 693 2.19 / 501.52 2 6
4 13 1172.56 18 14.86 1886 504 2.70 / 502.03 2 5
5 13 465.76 18 15.01 945 255 2.95 / 502.28 2 4
6 8 0.04 165 15.08 267 664 3.62 / 502.95 2 2
Average= 3.64
(KJ/cycle)

Cycle 136 GMT 1/ 5/2024 16: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 30 15.01 448 202 0.20 / 495.99 2 3
2 7 2009.80 30 14.82 2928 1302 1.50 / 497.29 2 2
3 13 1605.32 18 14.81 2435 649 2.15 / 497.94 2 6
4 13 1052.92 18 14.88 1727 463 2.62 / 498.40 2 4
5 13 493.16 18 14.98 983 265 2.88 / 498.67 2 3
6 8 0.16 165 15.07 267 664 3.54 / 499.33 2 2
Average= 3.64
(KJ/cycle)

Cycle 135 GMT 21/ 4/2024 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 30 15.02 428 193 0.19 / 492.15 2 3
2 7 2008.68 30 14.82 2932 1304 1.50 / 493.46 2 5
3 13 1749.16 18 14.79 2617 697 2.19 / 494.15 2 5
4 13 1164.76 18 14.84 1872 500 2.69 / 494.65 2 3
5 13 719.08 18 14.92 1284 345 3.04 / 495.00 2 4
6 13 97.16 18 15.07 438 119 3.16 / 495.12 2 3
7 8 0.00 165 15.06 269 668 3.83 / 495.79 2 3
Average= 3.65
(KJ/cycle)

Cycle 134 GMT 12/ 4/2024 1:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 31 15.02 444 207 0.21 / 488.47 2 3
2 7 2013.32 31 14.82 2937 1349 1.56 / 489.82 2 5
3 13 1616.44 18 14.81 2447 652 2.21 / 490.47 2 4
4 13 1184.48 18 14.84 1892 505 2.71 / 490.97 2 4
5 13 456.80 18 15.01 925 250 2.96 / 491.22 2 3
6 13 31.28 18 15.11 310 84 3.05 / 491.31 2 2
7 8 0.08 165 15.06 263 654 3.70 / 491.96 2 2
Average= 3.64
(KJ/cycle)

Cycle 133 GMT 2/ 4/2024 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 31 15.01 428 199 0.20 / 484.78 2 3
2 7 2012.92 30 14.81 2941 1307 1.51 / 486.08 2 2
3 13 1612.44 18 14.81 2436 649 2.16 / 486.73 2 4
4 13 1071.68 18 14.86 1745 467 2.62 / 487.20 2 4
5 13 632.00 18 14.95 1168 314 2.94 / 487.51 2 3
6 13 30.76 18 15.10 315 86 3.02 / 487.60 2 2
7 8 -0.20 165 15.06 266 661 3.68 / 488.26 2 2
Average= 3.64
(KJ/cycle)

Cycle 132 GMT 23/ 3/2024 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 31 15.01 428 199 0.20 / 480.98 2 3
2 7 2007.80 31 14.81 2931 1346 1.54 / 482.33 2 3
3 13 1729.60 18 14.79 2594 691 2.24 / 483.02 2 3
4 13 1276.00 18 14.82 2013 537 2.77 / 483.56 2 5
5 13 518.20 18 14.97 1013 273 3.05 / 483.83 2 5
6 13 42.92 18 15.09 333 90 3.14 / 483.92 2 2
7 8 0.16 165 15.06 264 656 3.79 / 484.58 2 3
Average= 3.64
(KJ/cycle)

Cycle 131 GMT 13/ 3/2024 16:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 31 15.02 418 195 0.19 / 477.35 2 3
2 3 1023.44 1 15.10 1737 26 0.22 / 477.38 2 3
3 7 2003.44 30 14.82 2915 1296 1.52 / 478.67 2 7
4 13 1597.72 18 14.81 2421 645 2.16 / 479.32 2 3
5 13 1054.56 18 14.86 1726 462 2.62 / 479.78 2 4
6 13 480.68 18 14.99 964 260 2.88 / 480.04 2 3
7 13 44.44 18 15.08 332 90 2.97 / 480.13 2 2
8 8 -0.12 165 15.04 263 653 3.63 / 480.78 2 3
Average= 3.64
(KJ/cycle)

Cycle 130 GMT 3/ 3/2024 21:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 30 15.03 437 197 0.20 / 473.72 2 3
2 7 2009.08 30 14.83 2940 1308 1.51 / 475.03 2 4
3 13 1612.20 18 14.82 2441 651 2.16 / 475.68 2 3
4 13 1066.00 18 14.88 1739 466 2.62 / 476.15 2 3
5 13 512.44 18 14.99 1003 271 2.89 / 476.42 2 4
6 13 48.36 18 15.09 342 93 2.99 / 476.51 2 2
7 8 0.16 165 15.07 260 647 3.63 / 477.16 2 4
Average= 3.64
(KJ/cycle)

Cycle 129 GMT 23/ 2/2024 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 30 15.03 433 195 0.20 / 469.86 2 3
2 7 2011.56 31 14.83 2935 1349 1.54 / 471.21 2 3
3 13 1764.20 18 14.79 2628 700 2.24 / 471.91 2 3
4 13 1138.16 18 14.86 1834 491 2.73 / 472.40 2 5
5 13 826.80 18 14.89 1425 382 3.12 / 472.78 2 4
6 13 34.68 18 15.10 317 86 3.20 / 472.87 2 2
7 8 0.00 165 15.06 265 658 3.86 / 473.53 2 3
Average= 3.64
(KJ/cycle)

Cycle 128 GMT 13/ 2/2024 7:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 30 15.03 431 194 0.19 / 466.03 2 3
2 3 1030.40 1 15.06 1731 26 0.22 / 466.06 2 4
3 7 2004.32 30 14.82 2923 1300 1.52 / 467.36 2 3
4 13 1602.04 18 14.81 2427 647 2.17 / 468.01 2 3
5 13 1165.40 18 14.84 1869 499 2.67 / 468.51 2 4
6 13 557.76 18 14.99 1072 289 2.96 / 468.80 2 3
7 13 52.40 18 15.09 353 96 3.05 / 468.89 2 2
8 8 0.08 165 15.06 263 654 3.70 / 469.54 2 2
9 14 0.08 30 15.04 265 120 3.82 / 469.66 2 3
Average= 3.64
(KJ/cycle)

Cycle 127 GMT 3/ 2/2024 12:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 29 15.01 441 192 0.19 / 462.26 2 3
2 10 1010.32 2 15.03 1708 51 0.24 / 462.31 2 3
3 3 960.56 -1 15.42 0 0 0.05 / 462.31 2 3
4 7 2005.56 30 14.82 2916 1296 1.54 / 463.61 2 3
5 13 1734.32 18 14.79 2588 689 2.23 / 464.30 2 4
6 13 1150.44 18 14.87 1842 493 2.72 / 464.79 2 4
7 13 551.68 18 14.97 1083 292 3.01 / 465.08 2 4
8 13 56.32 18 15.10 361 98 3.11 / 465.18 2 2
9 8 0.04 165 15.07 265 659 3.77 / 465.84 2 2
Average= 3.64
(KJ/cycle)

Cycle 126 GMT 24/ 1/2024 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 32 15.00 432 207 0.21 / 458.49 2 3
2 3 953.28 -1 15.41 0 0 0.00 / 458.49 2 3
3 3 973.36 -1 15.43 0 0 0.00 / 458.49 2 3
4 7 2004.68 30 14.81 2931 1302 1.51 / 459.80 2 3
5 13 1605.44 18 14.81 2432 648 2.16 / 460.44 2 3
6 13 1037.92 18 14.88 1700 455 2.61 / 460.90 2 3
7 13 595.20 18 14.96 1117 301 2.91 / 461.20 2 4
8 13 29.32 18 15.09 314 85 3.00 / 461.29 2 2
9 8 -0.20 165 15.05 267 663 3.66 / 461.95 2 2
10 14 -0.20 30 15.03 266 120 3.78 / 462.07 2 4
Average= 3.64
(KJ/cycle)

Cycle 125 GMT 14/ 1/2024 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 32 15.00 428 205 0.21 / 454.86 2 3
2 7 2009.00 30 14.82 2928 1302 1.51 / 456.16 2 4
3 13 1604.00 18 14.82 2437 650 2.16 / 456.81 2 7
4 13 1037.40 18 14.87 1715 459 2.62 / 457.27 2 6
5 13 477.64 18 14.98 962 259 2.88 / 457.53 2 3
6 13 17.12 18 15.10 302 82 2.96 / 457.61 2 2
7 8 -0.12 165 15.05 271 673 3.63 / 458.29 2 2
Average= 3.64
(KJ/cycle)

Cycle 124 GMT 4/ 1/2024 18:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 32 14.99 412 198 0.20 / 451.19 3 3
2 7 2003.20 30 14.82 2922 1299 1.50 / 452.49 2 3
3 13 1601.72 18 14.82 2416 644 2.14 / 453.13 2 4
4 13 1171.60 18 14.84 1880 502 2.64 / 453.63 2 5
5 13 574.72 18 14.95 1083 291 2.93 / 453.92 2 3
6 13 57.64 18 15.07 360 98 3.03 / 454.02 2 3
7 8 0.20 165 15.04 256 635 3.67 / 454.66 2 3
Average= 3.64
(KJ/cycle)

Cycle 123 GMT 25/12/2023 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 31 15.02 432 201 0.20 / 447.48 2 3
2 3 1019.48 1 15.15 1724 26 0.23 / 447.50 2 3
3 7 2004.60 30 14.84 2928 1304 1.53 / 448.81 2 3
4 13 1612.00 18 14.82 2438 650 2.18 / 449.46 2 5
5 13 1189.60 18 14.86 1895 507 2.69 / 449.96 2 4
6 13 594.04 18 14.96 1099 296 2.98 / 450.26 2 3
7 13 62.36 18 15.07 363 98 3.08 / 450.36 2 2
8 8 0.08 165 15.04 254 630 3.71 / 450.99 2 3
Average= 3.64
(KJ/cycle)

Cycle 122 GMT 15/12/2023 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 31 15.02 428 199 0.20 / 443.87 2 3
2 7 2006.16 30 14.84 2932 1305 1.50 / 445.17 2 5
3 13 1615.48 18 14.83 2441 652 2.16 / 445.82 2 5
4 13 1075.56 18 14.87 1746 467 2.62 / 446.29 2 4
5 13 508.92 18 14.99 981 265 2.89 / 446.55 2 3
6 13 45.84 18 15.08 333 90 2.98 / 446.64 2 2
7 8 0.04 165 15.05 254 631 3.61 / 447.28 2 3
Average= 3.64
(KJ/cycle)

Cycle 121 GMT 6/12/2023 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 31 15.02 433 202 0.20 / 440.24 2 3
2 7 2006.12 30 14.83 2923 1300 1.50 / 441.54 2 6
3 13 1613.24 18 14.83 2436 650 2.15 / 442.19 2 3
4 13 1071.76 18 14.88 1737 465 2.62 / 442.66 2 4
5 13 512.64 18 14.98 992 267 2.89 / 442.92 2 3
6 13 21.36 18 15.10 299 81 2.97 / 443.01 2 2
7 8 0.12 165 15.06 266 661 3.63 / 443.67 2 3
Average= 3.64
(KJ/cycle)

Cycle 120 GMT 26/11/2023 3:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 31 15.01 437 203 0.20 / 436.64 2 3
2 7 2007.96 30 14.83 2940 1308 1.51 / 437.95 2 5
3 13 1737.36 18 14.80 2604 694 2.21 / 438.65 2 3
4 13 1032.48 18 14.88 1694 454 2.66 / 439.10 2 6
5 13 593.48 18 14.96 1106 298 2.96 / 439.40 2 3
6 8 0.12 165 15.06 258 641 3.60 / 440.04 2 3
Average= 3.64
(KJ/cycle)

Cycle 119 GMT 16/11/2023 5:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 31 15.03 418 195 0.19 / 432.93 2 3
2 7 2004.80 31 14.83 2919 1342 1.54 / 434.28 2 7
3 13 1597.92 18 14.82 2433 649 2.19 / 434.93 2 4
4 13 1153.88 18 14.87 1846 494 2.68 / 435.42 2 4
5 13 557.00 18 14.97 1064 287 2.97 / 435.71 2 4
6 13 22.84 18 15.10 299 81 3.05 / 435.79 2 2
7 8 -0.12 165 15.06 263 654 3.70 / 436.44 2 3
Average= 3.64
(KJ/cycle)

Cycle 118 GMT 6/11/2023 8:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 15.03 431 201 0.20 / 429.26 2 3
2 7 2010.72 30 14.83 2921 1300 1.50 / 430.56 2 3
3 13 1734.20 18 14.81 2596 692 2.19 / 431.25 2 3
4 13 1040.60 18 14.89 1701 456 2.65 / 431.70 2 4
5 13 607.40 18 14.97 1128 304 2.95 / 432.01 2 3
6 13 25.68 18 15.10 298 81 3.03 / 432.09 2 2
7 8 -0.08 165 15.07 262 651 3.68 / 432.74 2 3
Average= 3.64
(KJ/cycle)

Cycle 117 GMT 27/10/2023 10:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 31 15.02 432 201 0.20 / 425.64 2 3
2 7 2005.08 30 14.85 2922 1302 1.50 / 426.94 2 3
3 13 1608.00 18 14.83 2444 652 2.16 / 427.59 2 4
4 13 1077.40 18 14.89 1754 470 2.63 / 428.06 2 3
5 13 503.68 18 15.00 989 267 2.89 / 428.33 2 3
6 13 15.84 18 15.10 288 78 2.97 / 428.41 2 2
7 8 -0.08 165 15.07 261 649 3.62 / 429.06 2 3
Average= 3.64
(KJ/cycle)

Cycle 116 GMT 17/10/2023 12:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 32 15.02 422 203 0.20 / 421.75 2 3
2 7 2004.68 30 14.85 2928 1304 1.51 / 423.06 2 4
3 13 1738.56 18 14.82 2602 694 2.20 / 423.75 2 6
4 13 1162.04 18 14.87 1862 498 2.70 / 424.25 2 3
5 13 706.92 18 14.95 1263 340 3.04 / 424.59 2 4
6 13 21.60 18 15.10 294 80 3.12 / 424.67 2 2
7 8 0.04 165 15.07 261 649 3.77 / 425.32 2 4
8 14 0.04 30 15.05 262 118 3.89 / 425.44 2 2
Average= 3.64
(KJ/cycle)

Cycle 115 GMT 7/10/2023 15:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 32 15.02 432 208 0.21 / 418.08 2 3
2 7 2011.44 30 14.83 2932 1304 1.51 / 419.38 2 7
3 13 1745.12 18 14.81 2611 696 2.21 / 420.08 2 6
4 13 1280.16 18 14.84 2013 538 2.75 / 420.61 2 4
5 13 550.28 18 14.98 1049 283 3.03 / 420.90 2 4
6 8 0.08 165 15.08 262 652 3.68 / 421.55 2 2
Average= 3.63
(KJ/cycle)

Cycle 114 GMT 27/ 9/2023 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 32 15.01 426 205 0.20 / 414.47 2 3
2 7 2013.20 30 14.83 2940 1308 1.51 / 415.78 2 5
3 13 1622.28 18 14.82 2456 655 2.17 / 416.43 2 2
4 13 1177.80 18 14.86 1876 502 2.67 / 416.93 2 3
5 13 579.96 18 14.97 1084 292 2.96 / 417.23 2 3
6 8 0.04 165 15.07 258 642 3.60 / 417.87 2 3
Average= 3.63
(KJ/cycle)

Cycle 113 GMT 17/ 9/2023 19:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 32 15.02 428 206 0.21 / 410.78 2 3
2 7 2003.80 30 14.83 2916 1297 1.50 / 412.08 2 3
3 13 1619.40 18 14.83 2449 654 2.16 / 412.74 2 3
4 13 1186.16 18 14.87 1885 505 2.66 / 413.24 2 4
5 13 599.96 18 14.97 1111 299 2.96 / 413.54 2 4
6 13 26.72 18 15.09 302 82 3.04 / 413.62 2 2
7 8 0.00 165 15.06 259 644 3.69 / 414.26 2 3
Average= 3.63
(KJ/cycle)

Cycle 112 GMT 7/ 9/2023 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 32 15.02 424 204 0.20 / 407.18 2 3
2 7 2012.52 30 14.84 2934 1306 1.51 / 408.49 2 3
3 13 1618.92 18 14.83 2451 654 2.16 / 409.14 2 4
4 13 1192.32 18 14.85 1897 507 2.67 / 409.65 2 4
5 13 596.00 18 14.96 1106 298 2.97 / 409.94 2 3
6 8 0.04 165 15.06 255 634 3.60 / 410.58 2 2
Average= 3.63
(KJ/cycle)

Cycle 111 GMT 29/ 8/2023 0:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 32 15.02 435 209 0.21 / 403.58 2 3
2 7 2012.32 30 14.84 2943 1310 1.52 / 404.89 2 5
3 13 1606.72 18 14.83 2437 651 2.17 / 405.54 2 4
4 13 1192.80 18 14.86 1891 506 2.68 / 406.05 2 4
5 13 600.88 18 14.97 1111 299 2.98 / 406.34 2 3
6 8 0.36 165 15.06 254 631 3.61 / 406.98 2 3
Average= 3.63
(KJ/cycle)

Cycle 110 GMT 19/ 8/2023 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 32 15.01 437 210 0.21 / 400.06 2 3
2 7 2003.76 30 14.86 2920 1302 1.51 / 401.36 2 7
3 13 1605.48 18 14.84 2433 650 2.16 / 402.01 2 6
4 13 1057.72 18 14.90 1721 462 2.62 / 402.47 2 4
5 13 496.64 18 15.00 967 261 2.88 / 402.73 2 3
6 8 0.04 165 15.07 256 637 3.52 / 403.37 2 4
Average= 3.63
(KJ/cycle)

Cycle 109 GMT 9/ 8/2023 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 31 15.03 430 200 0.20 / 396.38 2 3
2 3 1036.40 1 15.14 1750 26 0.23 / 396.41 2 3
3 7 2010.84 30 14.83 2924 1301 1.53 / 397.71 2 6
4 13 1742.52 18 14.81 2612 696 2.22 / 398.41 2 5
5 13 1158.36 18 14.86 1848 494 2.72 / 398.90 2 3
6 13 572.20 18 14.97 1076 290 3.01 / 399.19 2 3
7 8 0.20 165 15.06 264 656 3.66 / 399.85 2 3
Average= 3.63
(KJ/cycle)

Cycle 108 GMT 30/ 7/2023 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 32 15.03 419 202 0.20 / 392.75 2 3
2 10 1016.00 2 15.11 1703 51 0.25 / 392.80 2 3
3 3 965.04 -1 15.43 0 0 0.05 / 392.80 2 3
4 7 2007.88 30 14.86 2912 1298 1.55 / 394.10 2 7
5 13 1735.28 18 14.83 2589 691 2.24 / 394.79 2 6
6 13 1154.52 18 14.88 1844 494 2.74 / 395.29 2 5
7 13 457.48 18 15.01 910 246 2.98 / 395.53 2 3
8 8 0.12 165 15.06 263 654 3.64 / 396.18 2 3
Average= 3.63
(KJ/cycle)

Cycle 107 GMT 20/ 7/2023 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 32 15.02 457 220 0.22 / 389.04 2 3
2 7 2007.00 30 14.86 2927 1305 1.52 / 390.35 2 3
3 13 1624.32 18 14.83 2457 656 2.18 / 391.00 2 5
4 13 1191.40 18 14.87 1894 507 2.69 / 391.51 2 4
5 13 588.88 18 14.98 1094 295 2.98 / 391.81 2 3
6 13 51.28 18 15.09 345 94 3.08 / 391.90 2 2
7 8 0.04 165 15.07 261 649 3.73 / 392.55 2 3
Average= 3.63
(KJ/cycle)

Cycle 106 GMT 10/ 7/2023 11:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 32 15.02 428 206 0.21 / 385.26 2 3
2 7 2005.52 30 14.84 2924 1302 1.51 / 386.56 2 3
3 13 1730.12 18 14.81 2602 694 2.20 / 387.26 2 5
4 13 1146.52 18 14.87 1844 494 2.69 / 387.75 2 3
5 13 590.56 18 14.97 1112 300 2.99 / 388.05 2 4
6 13 23.04 18 15.09 316 86 3.08 / 388.14 2 2
7 8 0.12 165 15.05 277 688 3.77 / 388.82 2 4
Average= 3.63
(KJ/cycle)

Cycle 105 GMT 30/ 6/2023 14:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 32 15.02 448 215 0.22 / 381.54 2 3
2 7 2012.04 30 14.84 2935 1307 1.52 / 382.84 2 2
3 13 1610.64 18 14.83 2433 649 2.17 / 383.49 2 4
4 13 1186.60 18 14.86 1882 503 2.67 / 383.99 2 3
5 13 587.40 18 14.96 1090 294 2.97 / 384.29 2 3
6 8 -0.12 165 15.07 261 649 3.62 / 384.94 2 2
7 14 -0.12 30 15.05 263 119 3.74 / 385.06 2 5
Average= 3.63
(KJ/cycle)

Cycle 104 GMT 20/ 6/2023 16:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 32 15.03 428 206 0.21 / 377.88 2 3
2 7 2007.12 30 14.83 2934 1305 1.51 / 379.19 2 3
3 13 1739.20 18 14.80 2593 691 2.20 / 379.88 2 4
4 13 1159.84 18 14.87 1855 497 2.70 / 380.38 2 6
5 13 574.04 18 14.97 1075 290 2.99 / 380.67 2 3
6 8 0.12 165 15.06 263 654 3.64 / 381.32 2 2
Average= 3.63
(KJ/cycle)

Cycle 103 GMT 10/ 6/2023 18:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 32 15.05 437 210 0.21 / 374.22 2 3
2 7 2005.64 30 14.86 2928 1305 1.52 / 375.52 2 5
3 13 1607.48 18 14.85 2444 653 2.17 / 376.18 2 3
4 13 1069.16 18 14.91 1738 466 2.64 / 376.64 2 3
5 13 508.76 18 15.00 986 266 2.90 / 376.91 2 3
6 8 0.32 165 15.08 261 649 3.55 / 377.56 2 2
7 14 0.32 30 15.06 261 118 3.67 / 377.68 2 2
Average= 3.63
(KJ/cycle)

Cycle 102 GMT 31/ 5/2023 21: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.52 32 15.02 452 217 0.22 / 370.50 2 3
2 7 2011.20 30 14.87 2923 1304 1.52 / 371.81 2 8
3 13 1613.72 18 14.84 2437 651 2.17 / 372.46 2 3
4 13 1056.20 18 14.91 1725 463 2.64 / 372.92 2 3
5 13 622.88 18 14.98 1147 309 2.94 / 373.23 2 3
6 8 -0.04 165 15.08 265 659 3.60 / 373.89 2 2
7 14 -0.04 30 15.07 267 121 3.72 / 374.01 2 3
Average= 3.63
(KJ/cycle)

Cycle 101 GMT 21/ 5/2023 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 32 15.03 442 213 0.21 / 366.72 2 3
2 7 2004.20 30 14.86 2928 1305 1.52 / 368.02 2 4
3 13 1741.48 18 14.83 2608 696 2.21 / 368.72 2 7
4 13 1162.32 18 14.89 1862 499 2.71 / 369.22 2 3
5 13 591.40 18 14.99 1107 299 3.01 / 369.52 2 3
6 8 0.00 165 15.08 261 649 3.66 / 370.17 2 2
7 14 0.00 30 15.07 264 119 3.78 / 370.28 2 3
Average= 3.63
(KJ/cycle)

Cycle 100 GMT 12/ 5/2023 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 32 15.02 426 205 0.20 / 363.17 2 3
2 7 2004.40 30 14.87 2929 1307 1.51 / 364.47 2 5
3 13 1605.12 18 14.85 2431 650 2.16 / 365.12 2 4
4 13 1066.12 18 14.90 1735 465 2.63 / 365.59 2 4
5 13 503.72 18 15.01 982 265 2.89 / 365.85 2 3
6 8 0.16 165 15.08 261 649 3.54 / 366.50 2 2
Average= 3.63
(KJ/cycle)

Cycle 99 GMT 2/ 5/2023 3:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 32 15.03 429 206 0.21 / 359.54 2 3
2 7 2006.20 30 14.87 2926 1305 1.51 / 360.85 2 9
3 13 1613.12 18 14.85 2453 656 2.17 / 361.51 2 3
4 13 1192.72 18 14.87 1893 507 2.67 / 362.01 2 4
5 13 596.24 18 14.98 1111 300 2.97 / 362.31 2 3
6 8 -0.16 165 15.07 262 651 3.63 / 362.96 2 3
Average= 3.63
(KJ/cycle)

Cycle 98 GMT 22/ 4/2023 5:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 32 15.04 427 206 0.21 / 355.84 2 3
2 3 1016.28 1 15.18 1708 26 0.23 / 355.87 2 3
3 7 2007.56 30 14.86 2933 1308 1.54 / 357.18 2 5
4 13 1616.12 18 14.86 2449 655 2.19 / 357.83 2 3
5 13 1193.16 18 14.88 1903 510 2.70 / 358.34 2 3
6 13 467.04 18 15.01 925 250 2.95 / 358.59 2 3
7 8 0.32 165 15.08 253 630 3.58 / 359.22 2 5
8 14 0.32 30 15.06 256 116 3.70 / 359.34 2 3
Average= 3.63
(KJ/cycle)

Cycle 97 GMT 12/ 4/2023 7:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 31 15.04 431 201 0.20 / 352.15 2 3
2 7 2006.40 30 14.86 2918 1301 1.50 / 353.45 2 3
3 13 1739.08 18 14.84 2593 693 2.19 / 354.14 2 5
4 13 1151.48 18 14.89 1847 495 2.69 / 354.63 2 4
5 13 559.00 18 14.99 1056 285 2.97 / 354.92 2 4
6 13 24.88 18 15.11 296 81 3.05 / 355.00 2 2
7 8 -0.08 165 15.07 257 639 3.69 / 355.64 2 4
Average= 3.63
(KJ/cycle)

Cycle 96 GMT 2/ 4/2023 10:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 31 15.03 441 205 0.21 / 348.60 2 3
2 7 2004.56 30 14.86 2911 1298 1.50 / 349.90 2 7
3 13 1610.92 18 14.85 2436 651 2.15 / 350.55 2 5
4 13 1179.40 18 14.88 1882 504 2.66 / 351.05 2 4
5 13 460.80 18 15.02 923 250 2.91 / 351.30 2 3
6 8 0.28 165 15.08 258 642 3.55 / 351.94 2 3
Average= 3.63
(KJ/cycle)

Cycle 95 GMT 23/ 3/2023 12:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 31 15.04 438 204 0.20 / 344.92 2 3
2 7 2012.64 30 14.86 2923 1303 1.51 / 346.22 2 3
3 13 1746.56 18 14.83 2605 695 2.20 / 346.91 2 6
4 13 1049.96 18 14.91 1716 461 2.66 / 347.37 2 5
5 13 480.08 18 15.02 950 257 2.92 / 347.63 2 3
6 13 33.68 18 15.11 327 89 3.01 / 347.72 2 2
7 8 -0.04 165 15.08 271 674 3.68 / 348.40 2 4
Average= 3.63
(KJ/cycle)

Cycle 94 GMT 13/ 3/2023 14:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 31 15.05 429 200 0.20 / 341.21 2 3
2 7 2011.76 30 14.87 2940 1312 1.51 / 342.52 2 7
3 13 1615.80 18 14.86 2461 658 2.17 / 343.18 2 5
4 13 1066.80 18 14.91 1739 467 2.64 / 343.64 2 3
5 13 625.56 18 14.98 1154 311 2.95 / 343.95 2 3
6 13 34.68 18 15.12 324 88 3.04 / 344.04 2 2
7 8 -0.08 165 15.08 269 669 3.71 / 344.71 2 2
Average= 3.63
(KJ/cycle)

Cycle 93 GMT 3/ 3/2023 17: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 31 15.04 424 198 0.20 / 337.44 2 3
2 7 2010.32 30 14.86 2936 1309 1.51 / 338.75 2 7
3 13 1610.56 18 14.86 2439 652 2.16 / 339.40 2 3
4 13 1053.76 18 14.92 1723 463 2.62 / 339.86 2 4
5 13 489.88 18 15.02 974 263 2.88 / 340.13 2 3
6 13 23.00 18 15.12 310 84 2.97 / 340.21 2 2
7 8 -0.16 165 15.09 270 672 3.64 / 340.88 2 3
8 14 -0.16 30 15.06 269 122 3.76 / 341.01 2 3
Average= 3.63
(KJ/cycle)

Cycle 92 GMT 21/ 2/2023 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 32 15.03 424 204 0.20 / 333.70 2 3
2 7 2012.64 30 14.86 2953 1316 1.52 / 335.02 2 5
3 13 1738.20 18 14.85 2613 698 2.22 / 335.72 2 3
4 13 1151.20 18 14.89 1851 496 2.71 / 336.21 2 6
5 13 572.20 18 15.00 1082 292 3.01 / 336.50 2 3
6 13 30.52 18 15.12 309 84 3.09 / 336.59 2 2
7 8 0.20 165 15.08 263 654 3.75 / 337.24 2 3
Average= 3.63
(KJ/cycle)

Cycle 91 GMT 11/ 2/2023 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 32 15.05 427 206 0.21 / 329.95 2 3
2 7 2012.16 30 14.86 2920 1302 1.51 / 331.25 2 8
3 13 1614.92 18 14.86 2462 659 2.17 / 331.91 2 4
4 13 1052.96 18 14.91 1719 461 2.63 / 332.37 2 3
5 13 495.28 18 15.03 977 264 2.89 / 332.63 2 3
6 13 38.84 18 15.13 326 89 2.98 / 332.72 2 2
7 8 0.00 165 15.09 264 657 3.64 / 333.38 2 4
8 14 0.00 30 15.07 263 119 3.76 / 333.50 2 2
Average= 3.62
(KJ/cycle)

Cycle 90 GMT 1/ 2/2023 23:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 15.04 428 206 0.21 / 326.27 2 3
2 7 2012.32 30 14.88 2933 1309 1.52 / 327.57 2 3
3 13 1600.08 18 14.87 2429 650 2.17 / 328.22 2 5
4 13 1158.60 18 14.91 1859 499 2.66 / 328.72 2 4
5 13 563.64 18 15.01 1069 289 2.95 / 329.01 2 4
6 13 24.16 18 15.13 297 81 3.03 / 329.09 2 2
7 8 -0.04 165 15.10 260 648 3.68 / 329.74 2 4
Average= 3.62
(KJ/cycle)

Cycle 89 GMT 23/ 1/2023 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 32 15.04 436 210 0.21 / 322.55 2 3
2 7 2010.04 30 14.88 2933 1309 1.52 / 323.86 2 9
3 13 1614.60 18 14.86 2442 653 2.17 / 324.51 2 4
4 13 1183.76 18 14.89 1889 506 2.68 / 325.02 2 4
5 13 597.00 18 15.00 1114 301 2.98 / 325.32 2 3
6 13 26.48 18 15.13 304 83 3.06 / 325.40 2 2
7 8 0.00 165 15.09 264 657 3.72 / 326.06 2 3
Average= 3.62
(KJ/cycle)

Cycle 88 GMT 13/ 1/2023 4:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 15.05 431 208 0.21 / 318.99 2 3
2 7 2003.40 30 14.86 2929 1306 1.51 / 320.29 2 3
3 13 1723.92 18 14.84 2588 691 2.20 / 320.98 2 3
4 13 1022.88 18 14.92 1680 451 2.66 / 321.44 2 5
5 13 473.68 18 15.02 939 254 2.91 / 321.69 2 3
6 8 0.04 165 15.09 261 650 3.56 / 322.34 2 3
Average= 3.62
(KJ/cycle)

Cycle 87 GMT 3/ 1/2023 6:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 32 15.05 450 217 0.22 / 315.27 2 3
2 3 1017.00 1 15.19 1719 26 0.24 / 315.29 2 3
3 7 2006.68 30 14.88 2919 1303 1.55 / 316.60 2 8
4 13 1601.96 18 14.87 2434 651 2.20 / 317.25 2 3
5 13 1167.28 18 14.91 1864 500 2.70 / 317.75 2 4
6 13 587.20 18 15.00 1095 296 2.99 / 318.04 2 3
7 13 28.12 18 15.12 306 83 3.08 / 318.13 2 2
8 8 0.00 165 15.09 262 652 3.73 / 318.78 2 3
Average= 3.62
(KJ/cycle)

Cycle 86 GMT 24/12/2022 8:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 31 15.07 415 194 0.19 / 311.43 2 3
2 7 2009.80 30 14.88 2917 1302 1.50 / 312.73 2 3
3 13 1619.84 18 14.88 2454 657 2.15 / 313.39 2 3
4 13 1198.36 18 14.89 1904 510 2.66 / 313.90 2 4
5 13 488.68 18 15.03 961 260 2.92 / 314.16 2 3
6 13 18.04 18 15.13 307 84 3.01 / 314.24 2 2
7 8 0.20 165 15.09 276 687 3.69 / 314.93 2 3
8 14 0.20 30 15.07 276 125 3.82 / 315.05 2 3
Average= 3.62
(KJ/cycle)

Cycle 85 GMT 14/12/2022 11:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 31 15.09 444 208 0.21 / 307.76 2 3
2 3 1022.08 1 15.18 1733 26 0.23 / 307.79 2 3
3 7 2007.76 30 14.89 2913 1301 1.54 / 309.09 2 4
4 13 1620.12 18 14.87 2441 653 2.19 / 309.74 2 3
5 13 1190.96 18 14.90 1896 509 2.70 / 310.25 2 5
6 13 470.56 18 15.04 922 250 2.95 / 310.50 2 4
7 13 32.08 18 15.13 310 84 3.03 / 310.59 2 2
8 8 0.16 165 15.10 259 645 3.68 / 311.23 2 4
Average= 3.62
(KJ/cycle)

Cycle 84 GMT 4/12/2022 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 31 15.09 432 202 0.20 / 304.17 2 3
2 7 2002.92 30 14.89 2921 1305 1.51 / 305.47 2 5
3 13 1723.16 18 14.86 2588 692 2.20 / 306.17 2 4
4 13 1146.16 18 14.92 1840 494 2.69 / 306.66 2 6
5 13 451.16 18 15.06 905 245 2.94 / 306.90 2 3
6 8 -0.04 165 15.12 261 651 3.59 / 307.56 2 3
Average= 3.62
(KJ/cycle)

Cycle 83 GMT 24/11/2022 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 15.08 432 202 0.20 / 300.62 2 3
2 7 2006.36 30 14.91 2932 1311 1.51 / 301.93 2 3
3 13 1603.44 18 14.90 2432 652 2.17 / 302.58 2 4
4 13 1046.20 18 14.96 1711 461 2.63 / 303.04 2 6
5 13 479.00 18 15.07 955 259 2.89 / 303.30 2 3
6 8 0.24 165 15.13 267 667 3.55 / 303.97 2 3
Average= 3.62
(KJ/cycle)

Cycle 82 GMT 14/11/2022 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 31 15.07 437 204 0.20 / 296.97 2 3
2 7 2010.12 30 14.89 2928 1308 1.51 / 298.28 2 3
3 13 1583.92 18 14.89 2413 647 2.16 / 298.93 2 3
4 13 1158.24 18 14.92 1863 500 2.66 / 299.43 2 4
5 13 435.08 18 15.07 895 243 2.90 / 299.67 2 2
6 13 22.04 18 15.16 299 82 2.98 / 299.75 2 2
7 8 -0.16 165 15.13 265 662 3.65 / 300.41 2 3
Average= 3.62
(KJ/cycle)

Cycle 81 GMT 4/11/2022 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 31 15.10 445 208 0.21 / 293.24 2 3
2 7 2009.32 30 14.87 2937 1310 1.52 / 294.55 2 9
3 13 1727.48 18 14.85 2596 694 2.21 / 295.25 2 3
4 13 1144.44 18 14.91 1839 494 2.71 / 295.74 2 4
5 13 560.76 18 15.02 1068 289 2.99 / 296.03 2 3
6 13 26.88 18 15.15 304 83 3.08 / 296.11 2 2
7 8 0.28 165 15.11 263 656 3.73 / 296.77 2 3
Average= 3.62
(KJ/cycle)

Cycle 80 GMT 25/10/2022 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 31 15.10 429 201 0.20 / 289.62 2 2
2 7 2003.08 30 14.91 2933 1312 1.51 / 290.94 2 9
3 13 1732.32 18 14.88 2606 698 2.21 / 291.63 2 3
4 13 1150.48 18 14.94 1858 500 2.71 / 292.13 2 4
5 13 452.84 18 15.08 915 248 2.96 / 292.38 2 3
6 8 -0.12 165 15.14 262 655 3.61 / 293.04 2 3
Average= 3.62
(KJ/cycle)

Cycle 79 GMT 16/10/2022 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 31 15.09 435 203 0.20 / 285.99 2 3
2 7 2003.40 30 14.90 2925 1307 1.51 / 287.30 2 9
3 13 1606.00 18 14.88 2443 654 2.17 / 287.96 2 4
4 13 1178.48 18 14.91 1891 508 2.67 / 288.46 2 6
5 13 581.84 18 15.04 1099 298 2.97 / 288.76 2 3
6 8 0.04 165 15.14 265 662 3.63 / 289.42 2 2
Average= 3.62
(KJ/cycle)

Cycle 78 GMT 6/10/2022 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 31 15.10 442 207 0.21 / 282.43 2 3
2 7 2004.40 30 14.88 2922 1304 1.51 / 283.73 2 6
3 13 1589.88 18 14.88 2419 648 2.16 / 284.38 2 3
4 13 1160.36 18 14.92 1859 499 2.66 / 284.88 2 3
5 13 452.20 18 15.07 915 248 2.91 / 285.13 2 3
6 8 0.24 165 15.13 265 662 3.57 / 285.79 2 2
Average= 3.62
(KJ/cycle)

Cycle 77 GMT 26/ 9/2022 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 31 15.10 449 210 0.21 / 278.76 2 2
2 7 2004.40 30 14.89 2929 1308 1.52 / 280.07 2 3
3 13 1736.24 18 14.87 2607 698 2.22 / 280.77 2 3
4 13 1143.56 18 14.93 1838 494 2.71 / 281.26 2 6
5 13 559.96 18 15.05 1067 289 3.00 / 281.55 2 3
6 8 0.20 165 15.14 269 672 3.67 / 282.22 2 2
Average= 3.62
(KJ/cycle)

Cycle 76 GMT 16/ 9/2022 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 31 15.11 452 212 0.21 / 274.97 2 3
2 7 2003.04 30 14.91 2925 1308 1.52 / 276.28 2 7
3 13 1729.92 18 14.87 2601 696 2.22 / 276.98 2 3
4 13 1140.60 18 14.95 1836 494 2.71 / 277.47 2 3
5 13 553.72 18 15.06 1056 286 3.00 / 277.76 2 4
6 8 -0.28 165 15.15 268 670 3.67 / 278.43 2 2
7 14 -0.28 30 15.13 271 123 3.79 / 278.55 2 3
Average= 3.62
(KJ/cycle)

Cycle 75 GMT 6/ 9/2022 10:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 31 15.11 435 204 0.20 / 271.32 2 2
2 7 2004.08 30 14.91 2931 1311 1.51 / 272.63 2 9
3 13 1604.32 18 14.90 2449 657 2.17 / 273.29 2 4
4 13 1154.56 18 14.95 1858 500 2.67 / 273.79 2 3
5 13 569.44 18 15.06 1077 292 2.96 / 274.08 2 4
6 8 -0.04 165 15.15 273 682 3.65 / 274.76 2 3
Average= 3.62
(KJ/cycle)

Cycle 74 GMT 27/ 8/2022 13: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 31 15.12 440 206 0.21 / 267.69 2 3
2 7 2008.56 30 14.90 2923 1307 1.51 / 268.99 2 7
3 13 1721.64 18 14.87 2572 688 2.20 / 269.68 2 3
4 13 1134.56 18 14.95 1827 492 2.69 / 270.17 2 3
5 13 538.32 18 15.06 1033 280 2.97 / 270.45 2 4
6 8 0.16 165 15.16 264 660 3.63 / 271.11 2 3
Average= 3.61
(KJ/cycle)

Cycle 73 GMT 17/ 8/2022 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 31 15.11 440 206 0.21 / 264.03 2 3
2 7 2003.96 30 14.90 2923 1307 1.51 / 265.34 2 5
3 13 1735.00 18 14.88 2600 696 2.21 / 266.04 2 3
4 13 1138.48 18 14.95 1831 493 2.70 / 266.53 2 4
5 13 551.08 18 15.06 1055 286 2.99 / 266.81 2 3
6 8 0.08 165 15.16 267 668 3.66 / 267.48 2 2
Average= 3.61
(KJ/cycle)

Cycle 72 GMT 7/ 8/2022 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 31 15.13 447 210 0.21 / 260.46 2 3
2 7 2011.20 30 14.89 2936 1312 1.52 / 261.77 2 4
3 13 1616.16 18 14.88 2450 656 2.18 / 262.43 2 4
4 13 1058.28 18 14.95 1733 466 2.64 / 262.89 2 4
5 13 484.84 18 15.07 964 261 2.91 / 263.15 2 3
6 8 0.04 165 15.15 269 672 3.58 / 263.83 2 2
Average= 3.61
(KJ/cycle)

Cycle 71 GMT 28/ 7/2022 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 31 15.12 441 207 0.21 / 256.84 2 3
2 7 2013.28 30 14.91 2946 1318 1.52 / 258.16 2 4
3 13 1614.28 18 14.89 2450 657 2.18 / 258.81 2 4
4 13 1182.16 18 14.93 1890 508 2.69 / 259.32 2 3
5 13 466.52 18 15.09 941 256 2.94 / 259.58 2 3
6 8 -0.12 165 15.16 268 670 3.61 / 260.25 2 2
Average= 3.61
(KJ/cycle)

Cycle 70 GMT 18/ 7/2022 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 31 15.13 440 206 0.21 / 253.07 2 3
2 7 2012.56 30 14.91 2930 1311 1.52 / 254.38 2 7
3 13 1609.68 18 14.89 2456 658 2.18 / 255.04 2 3
4 13 1176.32 18 14.94 1892 509 2.68 / 255.55 2 4
5 13 583.92 18 15.06 1101 298 2.98 / 255.84 2 3
6 8 0.16 165 15.17 266 666 3.65 / 256.51 2 3
7 14 0.16 30 15.15 270 123 3.77 / 256.63 2 3
Average= 3.61
(KJ/cycle)

Cycle 69 GMT 9/ 7/2022 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 31 15.12 433 203 0.20 / 249.31 2 2
2 7 2004.84 30 14.91 2928 1310 1.51 / 250.62 2 9
3 13 1609.20 18 14.90 2449 657 2.17 / 251.28 2 3
4 13 1169.56 18 14.94 1884 507 2.68 / 251.78 2 3
5 13 463.04 18 15.10 933 254 2.93 / 252.04 2 3
6 8 0.08 165 15.17 279 698 3.63 / 252.74 2 2
7 14 0.08 30 15.15 277 126 3.75 / 252.86 2 3
Average= 3.61
(KJ/cycle)

Cycle 68 GMT 29/ 6/2022 2:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 31 15.14 442 207 0.21 / 245.81 2 3
2 7 2011.48 30 14.92 2938 1315 1.52 / 247.12 2 4
3 13 1493.32 18 14.92 2302 618 2.14 / 247.74 2 6
4 13 1090.08 18 14.96 1774 478 2.62 / 248.22 2 3
5 13 386.60 18 15.12 829 226 2.84 / 248.45 2 3
6 8 -0.04 165 15.16 265 663 3.51 / 249.11 2 3
Average= 3.61
(KJ/cycle)

Cycle 67 GMT 19/ 6/2022 4:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 31 15.11 449 210 0.21 / 242.15 2 2
2 7 2003.56 30 14.91 2920 1306 1.52 / 243.45 2 10
3 13 1609.36 18 14.91 2442 655 2.17 / 244.11 2 4
4 13 1181.56 18 14.94 1892 509 2.68 / 244.62 2 3
5 13 607.00 18 15.07 1133 307 2.99 / 244.92 2 3
6 8 0.24 165 15.17 271 678 3.67 / 245.60 2 2
Average= 3.61
(KJ/cycle)

Cycle 66 GMT 9/ 6/2022 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 31 15.14 436 205 0.20 / 238.26 2 2
2 7 2010.04 30 14.92 2926 1310 1.51 / 239.57 2 3
3 13 1719.24 18 14.90 2581 692 2.21 / 240.26 2 6
4 13 1145.76 18 14.96 1839 495 2.70 / 240.76 2 3
5 13 555.88 18 15.09 1065 289 2.99 / 241.05 2 3
6 13 20.20 18 15.21 308 84 3.08 / 241.13 2 2
7 8 0.04 165 15.18 272 681 3.76 / 241.81 2 2
8 14 0.04 30 15.15 274 125 3.88 / 241.94 2 2
Average= 3.61
(KJ/cycle)

Cycle 65 GMT 30/ 5/2022 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 31 15.15 428 201 0.20 / 234.60 2 3
2 7 2004.84 30 14.92 2924 1309 1.51 / 235.91 2 5
3 13 1745.40 18 14.88 2616 701 2.21 / 236.61 2 6
4 13 1149.12 18 14.96 1843 496 2.71 / 237.10 2 4
5 13 559.48 18 15.08 1061 288 2.99 / 237.39 2 3
6 8 -0.36 165 15.18 264 661 3.66 / 238.05 2 2
Average= 3.61
(KJ/cycle)

Cycle 64 GMT 20/ 5/2022 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 31 15.15 443 208 0.21 / 231.02 2 3
2 7 2009.16 30 14.92 2929 1311 1.52 / 232.33 2 6
3 13 1723.96 18 14.90 2599 697 2.22 / 233.03 2 4
4 13 1023.84 18 14.99 1681 454 2.67 / 233.48 2 4
5 13 457.80 18 15.11 927 252 2.92 / 233.74 2 3
6 8 -0.04 165 15.18 264 661 3.58 / 234.40 2 2
Average= 3.61
(KJ/cycle)

Cycle 63 GMT 10/ 5/2022 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 31 15.16 434 204 0.20 / 227.34 2 3
2 7 2010.20 30 14.93 2928 1311 1.52 / 228.65 2 8
3 13 1614.00 18 14.91 2446 656 2.17 / 229.30 2 3
4 13 1192.04 18 14.96 1900 512 2.68 / 229.82 2 4
5 13 450.00 18 15.11 911 248 2.93 / 230.06 2 3
6 13 34.52 18 15.22 321 88 3.02 / 230.15 2 2
7 8 0.28 165 15.18 265 664 3.68 / 230.82 2 3
Average= 3.61
(KJ/cycle)

Cycle 62 GMT 30/ 4/2022 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 15.17 428 201 0.20 / 223.60 2 3
2 7 2011.04 30 14.93 2933 1314 1.51 / 224.91 2 7
3 13 1730.04 18 14.91 2597 697 2.21 / 225.61 2 3
4 13 1023.88 18 15.01 1684 455 2.67 / 226.07 2 4
5 13 609.36 18 15.10 1132 308 2.97 / 226.37 2 3
6 13 23.80 18 15.24 308 84 3.06 / 226.46 2 2
7 8 0.04 165 15.20 269 675 3.73 / 227.13 2 2
Average= 3.61
(KJ/cycle)

Cycle 61 GMT 20/ 4/2022 18:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 31 15.16 430 202 0.20 / 219.92 2 2
2 7 2003.24 30 14.93 2933 1314 1.52 / 221.23 2 7
3 13 1600.96 18 14.92 2447 657 2.17 / 221.89 2 3
4 13 1167.76 18 14.98 1875 506 2.68 / 222.39 2 4
5 13 443.16 18 15.13 906 247 2.93 / 222.64 2 3
6 13 29.20 18 15.24 315 86 3.01 / 222.73 2 2
7 8 -0.08 165 15.20 268 672 3.68 / 223.40 2 3
Average= 3.60
(KJ/cycle)

Cycle 60 GMT 10/ 4/2022 20:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 31 15.18 439 207 0.21 / 216.10 2 3
2 7 2015.72 30 14.92 2941 1316 1.52 / 217.42 2 3
3 13 1887.12 18 14.88 2804 751 2.27 / 218.17 2 5
4 13 1220.68 18 14.97 1948 525 2.80 / 218.69 2 4
5 13 479.20 18 15.14 959 261 3.06 / 218.96 2 3
6 13 33.92 18 15.24 322 88 3.15 / 219.04 2 2
7 8 -0.28 165 15.21 267 670 3.82 / 219.71 2 3
Average= 3.60
(KJ/cycle)

Cycle 59 GMT 31/ 3/2022 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 31 15.17 433 204 0.20 / 212.35 2 3
2 7 2003.00 30 14.92 2926 1310 1.51 / 213.66 2 5
3 13 1731.48 18 14.90 2603 698 2.21 / 214.36 2 4
4 13 1145.36 18 15.00 1845 498 2.71 / 214.86 2 4
5 13 434.48 18 15.15 899 245 2.95 / 215.10 2 3
6 8 0.52 165 15.22 267 671 3.63 / 215.77 2 2
7 14 0.52 30 15.19 267 122 3.75 / 215.90 2 4
Average= 3.60
(KJ/cycle)

Cycle 58 GMT 22/ 3/2022 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 31 15.17 439 206 0.21 / 208.76 2 3
2 7 2013.28 30 14.93 2944 1319 1.53 / 210.08 2 10
3 13 1617.92 18 14.92 2465 662 2.19 / 210.74 2 6
4 13 1066.92 18 15.02 1750 473 2.66 / 211.21 2 4
5 13 494.80 18 15.14 976 266 2.93 / 211.48 2 3
6 8 -0.12 165 15.23 267 671 3.60 / 212.15 2 3
Average= 3.60
(KJ/cycle)

Cycle 57 GMT 12/ 3/2022 3:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 31 15.17 432 203 0.20 / 205.01 2 3
2 7 2006.24 30 14.93 2935 1315 1.52 / 206.33 2 5
3 13 1605.80 18 14.92 2451 658 2.18 / 206.99 2 3
4 13 1182.56 18 14.98 1890 510 2.69 / 207.50 2 3
5 13 576.88 18 15.11 1093 297 2.98 / 207.79 2 3
6 13 25.72 18 15.25 311 85 3.07 / 207.88 2 2
7 8 -0.08 165 15.21 268 673 3.74 / 208.55 2 3
Average= 3.60
(KJ/cycle)

Cycle 56 GMT 2/ 3/2022 5:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 31 15.18 429 202 0.20 / 201.34 2 3
2 7 2008.88 30 14.94 2928 1312 1.51 / 202.65 2 7
3 13 1738.08 18 14.91 2621 703 2.22 / 203.35 2 3
4 13 1014.20 18 15.04 1676 454 2.67 / 203.81 2 5
5 13 446.72 18 15.16 914 249 2.92 / 204.06 2 3
6 13 24.52 18 15.26 309 85 3.01 / 204.14 2 2
7 8 0.16 165 15.22 267 671 3.68 / 204.81 2 3
Average= 3.59
(KJ/cycle)

Cycle 55 GMT 20/ 2/2022 7:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 31 15.18 442 208 0.21 / 197.46 2 2
2 7 2010.36 30 14.94 2940 1318 1.53 / 198.78 2 5
3 13 1739.52 18 14.92 2603 699 2.22 / 199.48 2 4
4 13 1138.08 18 15.01 1838 497 2.72 / 199.97 2 3
5 13 551.84 18 15.14 1055 288 3.01 / 200.26 2 4
6 13 18.68 18 15.26 297 82 3.09 / 200.34 2 2
7 8 0.08 165 15.23 267 671 3.76 / 201.01 2 2
8 14 0.08 30 15.21 267 122 3.88 / 201.13 2 2
Average= 3.59
(KJ/cycle)

Cycle 54 GMT 10/ 2/2022 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 31 15.20 443 209 0.21 / 193.69 2 3
2 7 2005.68 30 14.94 2928 1312 1.52 / 195.01 2 3
3 13 1715.32 18 14.92 2577 692 2.21 / 195.70 2 7
4 13 1140.28 18 15.01 1848 499 2.71 / 196.20 2 3
5 13 557.44 18 15.16 1067 291 3.00 / 196.49 2 3
6 13 19.88 18 15.27 299 82 3.09 / 196.57 2 2
7 8 0.20 165 15.24 271 681 3.77 / 197.25 2 3
Average= 3.59
(KJ/cycle)

Cycle 53 GMT 31/ 1/2022 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 31 15.20 437 206 0.21 / 189.99 2 3
2 7 2009.92 30 14.94 2934 1315 1.52 / 191.31 2 7
3 13 1583.96 18 14.95 2423 652 2.17 / 191.96 2 5
4 13 1165.60 18 15.01 1881 508 2.68 / 192.47 2 5
5 13 430.52 18 15.19 893 244 2.93 / 192.71 2 2
6 13 23.12 18 15.28 311 86 3.01 / 192.80 2 2
7 8 -0.24 165 15.24 273 686 3.70 / 193.48 2 2
Average= 3.58
(KJ/cycle)

Cycle 52 GMT 21/ 1/2022 15: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 31 15.21 430 203 0.20 / 186.40 2 3
2 7 2006.84 30 14.95 2930 1314 1.52 / 187.72 2 5
3 13 1604.96 18 14.95 2438 656 2.17 / 188.37 2 4
4 13 1048.88 18 15.04 1719 465 2.64 / 188.84 2 3
5 13 488.04 18 15.19 969 265 2.90 / 189.11 2 3
6 8 0.04 165 15.25 271 682 3.59 / 189.79 2 2
Average= 3.58
(KJ/cycle)

Cycle 51 GMT 11/ 1/2022 17:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 31 15.22 447 211 0.21 / 182.63 2 3
2 7 2002.88 30 14.96 2923 1312 1.52 / 183.95 2 11
3 13 1726.36 18 14.93 2600 699 2.22 / 184.64 2 3
4 13 1149.64 18 15.02 1852 501 2.72 / 185.15 2 4
5 13 542.64 18 15.17 1043 285 3.01 / 185.43 2 3
6 13 35.08 18 15.29 327 90 3.10 / 185.52 2 2
7 8 0.16 165 15.25 271 682 3.78 / 186.20 2 3
Average= 3.58
(KJ/cycle)

Cycle 50 GMT 1/ 1/2022 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 31 15.21 445 210 0.21 / 178.79 2 2
2 7 2011.96 31 14.96 2937 1362 1.57 / 180.15 2 5
3 13 1605.84 18 14.96 2429 654 2.23 / 180.80 2 4
4 13 1177.84 18 15.01 1894 512 2.74 / 181.31 2 4
5 13 587.92 18 15.16 1109 303 3.04 / 181.62 2 3
6 8 -0.04 165 15.26 271 682 3.72 / 182.30 2 3
7 14 -0.04 30 15.24 273 125 3.85 / 182.42 2 2
Average= 3.58
(KJ/cycle)

Cycle 49 GMT 22/12/2021 22: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 31 15.22 440 208 0.21 / 175.23 2 2
2 7 2010.84 30 14.96 2942 1320 1.53 / 176.55 2 7
3 13 1605.40 18 14.96 2445 658 2.19 / 177.21 2 4
4 13 1044.04 18 15.06 1719 466 2.65 / 177.67 2 3
5 13 344.92 18 15.23 781 214 2.87 / 177.89 2 3
6 8 0.00 165 15.27 273 688 3.55 / 178.58 2 2
Average= 3.57
(KJ/cycle)

Cycle 48 GMT 13/12/2021 0:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 31 15.23 439 207 0.21 / 171.54 2 2
2 7 2002.68 30 14.97 2921 1312 1.52 / 172.85 2 5
3 13 1719.44 18 14.96 2595 699 2.22 / 173.55 2 3
4 13 1127.72 18 15.04 1828 495 2.71 / 174.05 2 3
5 13 534.92 18 15.18 1032 282 2.99 / 174.33 2 3
6 8 0.08 165 15.27 275 693 3.69 / 175.02 2 2
Average= 3.57
(KJ/cycle)

Cycle 47 GMT 3/12/2021 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 31 15.22 442 209 0.21 / 167.90 2 2
2 7 2005.64 31 14.97 2939 1364 1.57 / 169.26 2 6
3 13 1612.48 18 14.97 2448 660 2.23 / 169.92 2 4
4 13 1049.92 18 15.06 1722 467 2.70 / 170.39 2 4
5 13 478.84 18 15.19 957 262 2.96 / 170.65 2 3
6 8 0.08 165 15.28 271 683 3.64 / 171.33 2 2
Average= 3.57
(KJ/cycle)

Cycle 46 GMT 23/11/2021 5: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 31 15.23 442 209 0.21 / 164.29 2 3
2 7 2009.80 30 14.96 2931 1315 1.52 / 165.61 2 4
3 13 1618.72 18 14.97 2455 662 2.19 / 166.27 2 4
4 13 1070.84 18 15.04 1747 473 2.66 / 166.74 2 3
5 13 493.24 18 15.18 986 269 2.93 / 167.01 2 3
6 8 0.40 165 15.26 270 680 3.61 / 167.69 2 2
Average= 3.57
(KJ/cycle)

Cycle 45 GMT 13/11/2021 7:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 15.23 445 210 0.21 / 160.68 2 3
2 7 2006.56 30 14.97 2931 1316 1.53 / 162.00 2 11
3 13 1612.28 18 14.97 2458 662 2.19 / 162.66 2 4
4 13 1067.96 18 15.05 1750 474 2.66 / 163.13 2 3
5 13 492.64 18 15.19 977 267 2.93 / 163.40 2 3
6 8 -0.28 165 15.27 270 680 3.61 / 164.08 2 2
Average= 3.57
(KJ/cycle)

Cycle 44 GMT 3/11/2021 9:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 31 15.24 442 209 0.21 / 157.10 2 2
2 7 2005.16 30 14.96 2925 1313 1.52 / 158.41 2 5
3 13 1598.72 18 14.97 2429 655 2.18 / 159.07 2 5
4 13 1044.72 18 15.06 1714 465 2.64 / 159.53 2 4
5 13 466.76 18 15.20 951 260 2.90 / 159.79 2 3
6 8 0.20 165 15.27 270 680 3.58 / 160.47 2 3
Average= 3.57
(KJ/cycle)

Cycle 43 GMT 24/10/2021 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 31 15.23 437 206 0.21 / 153.46 2 2
2 7 2003.96 31 14.97 2924 1357 1.56 / 154.81 2 3
3 13 1609.48 18 14.98 2443 659 2.22 / 155.47 2 3
4 13 1067.44 18 15.06 1743 472 2.69 / 155.94 2 4
5 13 486.28 18 15.20 963 263 2.96 / 156.21 2 3
6 8 0.12 165 15.27 271 683 3.64 / 156.89 2 3
Average= 3.57
(KJ/cycle)

Cycle 42 GMT 14/10/2021 14:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 31 15.25 439 208 0.21 / 149.76 2 2
2 7 2005.08 30 14.97 2918 1310 1.52 / 151.07 2 7
3 13 1608.96 18 14.97 2447 659 2.18 / 151.73 2 3
4 13 1045.84 18 15.07 1711 464 2.64 / 152.19 2 5
5 13 494.80 18 15.19 975 267 2.91 / 152.46 2 3
6 8 0.24 165 15.28 266 671 3.58 / 153.13 2 2
7 14 0.24 30 15.26 266 122 3.70 / 153.25 2 2
Average= 3.56
(KJ/cycle)

Cycle 41 GMT 4/10/2021 16:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 31 15.25 435 206 0.21 / 146.18 2 3
2 7 2004.16 30 14.97 2929 1315 1.52 / 147.49 2 4
3 13 1602.44 18 14.99 2440 658 2.18 / 148.15 2 3
4 13 1050.96 18 15.07 1723 467 2.65 / 148.62 2 4
5 13 466.24 18 15.20 939 257 2.90 / 148.87 2 3
6 8 -0.08 165 15.28 268 676 3.58 / 149.55 2 2
Average= 3.56
(KJ/cycle)

Cycle 40 GMT 24/ 9/2021 18:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 31 15.25 436 206 0.21 / 142.37 2 2
2 7 2004.88 30 14.99 2933 1319 1.53 / 143.69 2 7
3 13 1729.24 18 14.97 2606 702 2.23 / 144.39 2 3
4 13 1144.68 18 15.06 1847 501 2.73 / 144.89 2 4
5 13 457.84 18 15.22 925 253 2.98 / 145.14 2 3
6 8 0.24 165 15.28 278 701 3.68 / 145.84 2 3
7 14 0.24 30 15.27 276 126 3.81 / 145.97 2 2
Average= 3.56
(KJ/cycle)

Cycle 39 GMT 14/ 9/2021 21:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 31 15.25 452 214 0.21 / 138.71 2 2
2 7 2012.88 31 14.98 2940 1365 1.58 / 140.08 2 11
3 13 1606.64 18 14.99 2449 661 2.24 / 140.74 2 4
4 13 1046.08 18 15.08 1718 466 2.71 / 141.21 2 4
5 13 479.56 18 15.21 955 261 2.97 / 141.47 2 3
6 8 0.16 165 15.29 275 694 3.66 / 142.16 2 2
Average= 3.55
(KJ/cycle)

Cycle 38 GMT 4/ 9/2021 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 31 15.26 439 208 0.21 / 135.01 2 2
2 7 2007.56 30 14.98 2925 1314 1.52 / 136.32 2 11
3 13 1722.08 18 14.97 2589 698 2.22 / 137.02 2 4
4 13 1138.08 18 15.07 1844 500 2.72 / 137.52 2 4
5 13 541.16 18 15.20 1041 285 3.00 / 137.81 2 3
6 8 0.00 165 15.30 275 694 3.70 / 138.50 2 3
Average= 3.55
(KJ/cycle)

Cycle 37 GMT 26/ 8/2021 1:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 30 15.27 460 211 0.21 / 131.33 2 3
2 7 2006.64 30 14.98 2927 1315 1.53 / 132.64 2 6
3 13 1599.60 18 15.00 2435 657 2.18 / 133.30 2 5
4 13 1041.24 18 15.10 1712 465 2.65 / 133.77 2 3
5 13 364.72 18 15.25 799 219 2.87 / 133.99 2 2
6 8 0.16 165 15.30 273 689 3.56 / 134.68 2 2
7 14 0.16 30 15.28 274 126 3.68 / 134.80 2 3
Average= 3.55
(KJ/cycle)

Cycle 36 GMT 16/ 8/2021 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 30 15.26 459 210 0.21 / 127.60 2 2
2 7 2009.16 30 15.00 2941 1323 1.53 / 128.92 2 3
3 13 1604.24 18 15.00 2436 658 2.19 / 129.58 2 3
4 13 1052.80 18 15.09 1729 470 2.66 / 130.05 2 5
5 13 472.08 18 15.23 949 260 2.92 / 130.31 2 2
6 8 -0.08 165 15.31 270 682 3.60 / 130.99 2 2
7 14 -0.08 30 15.28 272 125 3.73 / 131.12 2 3
Average= 3.54
(KJ/cycle)

Cycle 35 GMT 6/ 8/2021 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 31 15.25 440 208 0.21 / 123.86 2 2
2 7 2009.52 30 15.00 2945 1325 1.53 / 125.19 2 10
3 13 1612.64 18 15.01 2449 662 2.19 / 125.85 2 4
4 13 1057.32 18 15.10 1732 471 2.67 / 126.32 2 5
5 13 490.48 18 15.22 971 266 2.93 / 126.58 2 3
6 8 0.12 165 15.31 270 682 3.61 / 127.27 2 2
7 14 0.12 30 15.29 271 124 3.74 / 127.39 2 2
Average= 3.54
(KJ/cycle)

Cycle 34 GMT 27/ 7/2021 7:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 30 15.26 458 210 0.21 / 120.14 2 3
2 7 2010.92 30 14.98 2923 1314 1.52 / 121.46 2 3
3 13 1603.44 18 14.99 2438 658 2.18 / 122.12 2 4
4 13 1046.16 18 15.10 1725 469 2.65 / 122.58 2 4
5 13 489.08 18 15.21 968 265 2.91 / 122.85 2 3
6 8 0.16 165 15.29 269 679 3.59 / 123.53 2 2
7 14 0.16 30 15.28 269 123 3.72 / 123.65 2 2
Average= 3.53
(KJ/cycle)

Cycle 33 GMT 17/ 7/2021 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 15.27 450 206 0.21 / 116.48 2 2
2 7 2004.32 31 14.99 2938 1365 1.57 / 117.84 2 3
3 13 1596.76 18 15.02 2431 657 2.23 / 118.50 2 4
4 13 1155.96 18 15.07 1858 504 2.73 / 119.00 2 3
5 13 423.04 18 15.26 878 241 2.97 / 119.25 2 3
6 8 -0.20 165 15.31 273 690 3.66 / 119.93 2 2
Average= 3.53
(KJ/cycle)

Cycle 32 GMT 7/ 7/2021 12:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 30 15.27 453 208 0.21 / 112.93 2 3
2 7 2004.32 30 15.00 2931 1319 1.53 / 114.25 2 8
3 13 1609.32 18 15.02 2443 660 2.19 / 114.91 2 3
4 13 1035.20 18 15.11 1700 462 2.65 / 115.37 2 3
5 13 333.80 18 15.28 768 211 2.86 / 115.58 2 2
6 8 0.24 165 15.31 272 687 3.55 / 116.27 2 2
Average= 3.52
(KJ/cycle)

Cycle 31 GMT 27/ 6/2021 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 30 15.26 442 202 0.20 / 109.24 2 2
2 7 2004.48 30 14.98 2930 1317 1.52 / 110.55 2 10
3 13 1725.88 18 14.97 2591 698 2.22 / 111.25 2 4
4 13 1014.76 18 15.10 1671 454 2.67 / 111.70 2 5
5 13 317.92 18 15.27 741 204 2.88 / 111.91 2 3
6 8 0.20 165 15.30 273 689 3.56 / 112.60 2 3
7 14 0.20 30 15.29 275 126 3.69 / 112.72 2 3
Average= 3.52
(KJ/cycle)

Cycle 30 GMT 17/ 6/2021 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 30 15.29 438 201 0.20 / 105.50 2 2
2 7 2002.88 30 15.00 2929 1318 1.52 / 106.82 2 9
3 13 1721.60 18 15.00 2580 697 2.22 / 107.52 2 4
4 13 1137.44 18 15.09 1828 497 2.71 / 108.02 2 4
5 13 392.20 18 15.25 835 229 2.94 / 108.24 2 3
6 8 0.60 165 15.31 264 667 3.61 / 108.91 2 2
7 14 0.60 30 15.29 266 122 3.73 / 109.03 2 3
Average= 3.52
(KJ/cycle)

Cycle 29 GMT 7/ 6/2021 18:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 30 15.28 434 199 0.20 / 101.83 2 3
2 7 2005.60 30 15.02 2934 1322 1.52 / 103.16 2 6
3 13 1597.28 18 15.03 2426 656 2.18 / 103.81 2 5
4 13 1151.16 18 15.11 1854 504 2.68 / 104.32 2 5
5 13 424.92 18 15.27 881 242 2.92 / 104.56 2 3
6 13 17.48 18 15.36 289 80 3.00 / 104.64 2 2
7 8 -0.24 165 15.33 263 665 3.67 / 105.30 2 2
Average= 3.51
(KJ/cycle)

Cycle 28 GMT 28/ 5/2021 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 30 15.27 447 205 0.20 / 97.98 2 2
2 7 2009.32 30 15.01 2930 1319 1.52 / 99.30 2 7
3 13 1603.48 18 15.02 2441 660 2.18 / 99.96 2 4
4 13 1043.96 18 15.12 1710 465 2.65 / 100.43 2 4
5 13 608.76 18 15.22 1128 309 2.96 / 100.74 2 4
6 13 48.00 18 15.35 346 96 3.05 / 100.83 2 2
7 8 0.04 165 15.32 269 680 3.73 / 101.51 2 3
8 14 0.04 30 15.30 269 123 3.86 / 101.63 2 4
Average= 3.50
(KJ/cycle)

Cycle 27 GMT 18/ 5/2021 23: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 30 15.29 434 199 0.20 / 94.26 2 3
2 7 2004.64 30 15.01 2927 1318 1.52 / 95.58 2 6
3 13 1604.44 18 15.02 2444 661 2.18 / 96.24 2 3
4 13 1161.76 18 15.09 1867 507 2.68 / 96.74 2 4
5 13 427.88 18 15.26 882 242 2.93 / 96.99 2 3
6 8 0.16 165 15.33 264 668 3.60 / 97.65 2 2
7 14 0.16 30 15.31 266 122 3.72 / 97.78 2 3
Average= 3.49
(KJ/cycle)

Cycle 26 GMT 9/ 5/2021 1:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 30 15.30 444 204 0.20 / 90.65 2 2
2 7 2004.08 30 15.02 2924 1318 1.52 / 91.96 2 9
3 13 1734.84 18 15.01 2604 704 2.22 / 92.67 2 4
4 13 1015.84 18 15.14 1675 456 2.68 / 93.12 2 3
5 13 472.60 18 15.26 944 259 2.94 / 93.38 2 3
6 8 0.00 165 15.33 267 675 3.62 / 94.06 2 2
Average= 3.48
(KJ/cycle)

Cycle 25 GMT 29/ 4/2021 3:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 30 15.30 435 200 0.20 / 87.01 2 2
2 7 2007.44 30 15.03 2935 1323 1.52 / 88.33 2 7
3 13 1603.24 18 15.04 2444 662 2.18 / 88.99 2 4
4 13 1196.28 18 15.09 1910 519 2.70 / 89.51 2 3
5 13 472.16 18 15.26 940 258 2.96 / 89.77 2 2
6 8 0.28 165 15.34 267 676 3.64 / 90.44 2 2
Average= 3.48
(KJ/cycle)

Cycle 24 GMT 19/ 4/2021 5:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 15.30 431 198 0.20 / 83.43 2 2
2 7 2002.28 30 15.04 2919 1317 1.51 / 84.75 2 6
3 13 1714.36 18 15.04 2569 695 2.21 / 85.45 2 6
4 13 986.64 18 15.16 1632 445 2.66 / 85.89 2 3
5 13 426.56 18 15.28 880 242 2.90 / 86.13 2 3
6 8 0.00 165 15.34 266 673 3.57 / 86.81 2 2
Average= 3.47
(KJ/cycle)

Cycle 23 GMT 9/ 4/2021 8: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 30 15.30 434 199 0.20 / 79.84 2 2
2 7 2007.20 30 15.03 2925 1319 1.52 / 81.15 2 4
3 13 1599.88 18 15.05 2433 659 2.18 / 81.81 2 6
4 13 1157.08 18 15.12 1854 505 2.68 / 82.32 2 4
5 13 437.92 18 15.27 894 246 2.93 / 82.56 2 3
6 8 -0.12 165 15.34 265 671 3.60 / 83.23 2 2
Average= 3.47
(KJ/cycle)

Cycle 22 GMT 30/ 3/2021 10:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 30 15.30 433 199 0.20 / 76.21 2 2
2 7 2007.96 31 15.03 2938 1369 1.57 / 77.58 2 3
3 13 1598.24 18 15.04 2427 657 2.22 / 78.23 2 5
4 13 1163.36 18 15.11 1861 506 2.73 / 78.74 2 6
5 13 405.64 18 15.28 852 234 2.97 / 78.97 2 3
6 8 -0.08 165 15.35 262 664 3.63 / 79.64 2 2
Average= 3.46
(KJ/cycle)

Cycle 21 GMT 20/ 3/2021 12:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 30 15.31 438 201 0.20 / 72.67 2 2
2 7 2004.00 30 15.05 2925 1321 1.52 / 73.99 2 8
3 13 1588.72 18 15.07 2423 657 2.18 / 74.65 2 3
4 13 1015.68 18 15.16 1670 456 2.63 / 75.11 2 5
5 13 429.56 18 15.28 880 242 2.88 / 75.35 2 3
6 8 0.24 165 15.34 261 661 3.54 / 76.01 2 2
Average= 3.45
(KJ/cycle)

Cycle 20 GMT 10/ 3/2021 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 15.31 420 193 0.19 / 69.04 2 3
2 3 1018.16 1 15.39 1730 27 0.22 / 69.07 2 3
3 7 2002.72 31 15.04 2913 1358 1.58 / 70.43 2 7
4 13 1584.92 18 15.09 2408 654 2.23 / 71.08 2 4
5 13 1021.92 18 15.16 1675 457 2.69 / 71.54 2 5
6 13 463.48 18 15.28 927 255 2.94 / 71.79 2 3
7 8 0.28 165 15.35 267 676 3.62 / 72.47 2 2
Average= 3.45
(KJ/cycle)

Cycle 19 GMT 28/ 2/2021 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 30 15.31 424 195 0.19 / 65.52 2 2
2 7 2003.00 30 15.04 2926 1320 1.51 / 66.84 2 4
3 13 1585.56 18 15.06 2409 653 2.17 / 67.49 2 5
4 13 1016.36 18 15.16 1668 455 2.62 / 67.95 2 4
5 13 440.08 18 15.29 903 249 2.87 / 68.20 2 3
6 8 -0.16 165 15.36 258 654 3.53 / 68.85 2 2
Average= 3.44
(KJ/cycle)

Cycle 18 GMT 18/ 2/2021 19:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 30 15.31 442 203 0.20 / 61.85 2 3
2 7 2005.84 31 15.05 2940 1372 1.57 / 63.22 2 3
3 13 1592.52 18 15.06 2417 655 2.23 / 63.88 2 4
4 13 1307.88 18 15.08 2049 556 2.79 / 64.43 2 5
5 13 406.36 18 15.30 853 235 3.02 / 64.67 2 3
6 8 0.20 165 15.35 260 659 3.68 / 65.32 2 2
Average= 3.44
(KJ/cycle)

Cycle 17 GMT 8/ 2/2021 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 30 15.31 428 197 0.20 / 58.19 2 2
2 7 2012.16 30 15.04 2933 1323 1.52 / 59.51 2 4
3 13 1593.72 18 15.07 2430 659 2.18 / 60.17 2 3
4 13 1042.64 18 15.16 1705 465 2.64 / 60.63 2 4
5 13 347.52 18 15.31 780 215 2.86 / 60.85 2 3
6 8 0.04 165 15.35 266 674 3.53 / 61.52 2 2
7 14 0.04 30 15.34 266 122 3.66 / 61.65 2 3
Average= 3.42
(KJ/cycle)

Cycle 16 GMT 30/ 1/2021 0: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 30 15.31 426 196 0.20 / 54.57 2 3
2 7 2005.36 30 15.03 2923 1318 1.51 / 55.89 2 3
3 13 1744.68 18 15.03 2603 704 2.22 / 56.59 2 3
4 13 1001.68 18 15.16 1652 451 2.67 / 57.04 2 3
5 13 551.20 18 15.26 1049 288 2.96 / 57.33 2 3
6 8 -0.04 165 15.35 261 661 3.62 / 57.99 2 2
Average= 3.41
(KJ/cycle)

Cycle 15 GMT 20/ 1/2021 2:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 15.33 420 193 0.19 / 50.70 2 3
2 7 2005.00 30 15.04 2920 1318 1.51 / 52.01 2 2
3 13 1750.48 18 15.04 2617 708 2.22 / 52.72 2 2
4 13 1049.52 18 15.16 1717 469 2.69 / 53.19 2 3
5 13 612.92 18 15.25 1127 309 3.00 / 53.50 2 3
6 13 25.36 18 15.39 304 84 3.08 / 53.58 2 2
7 8 0.16 165 15.35 263 666 3.75 / 54.25 2 2
8 14 0.16 30 15.35 264 122 3.87 / 54.37 2 3
Average= 3.40
(KJ/cycle)

Cycle 14 GMT 10/ 1/2021 4:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 30 15.31 437 201 0.20 / 47.12 2 2
2 7 2009.48 31 15.07 2927 1367 1.57 / 48.49 2 3
3 13 1485.72 18 15.10 2279 619 2.19 / 49.11 2 3
4 13 1073.32 18 15.16 1739 475 2.66 / 49.58 2 3
5 13 470.20 18 15.29 941 259 2.92 / 49.84 2 3
6 8 0.00 165 15.36 261 661 3.58 / 50.50 2 2
Average= 3.37
(KJ/cycle)

Cycle 13 GMT 31/12/2020 6:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 30 15.33 434 200 0.20 / 43.55 2 2
2 7 2009.84 30 15.05 2933 1324 1.52 / 44.87 2 3
3 13 1588.32 18 15.07 2410 654 2.18 / 45.53 2 3
4 13 1144.24 18 15.14 1835 500 2.68 / 46.03 2 3
5 13 393.28 18 15.30 841 232 2.91 / 46.26 2 2
6 8 0.08 165 15.35 261 661 3.57 / 46.92 2 2
Average= 3.35
(KJ/cycle)

Cycle 12 GMT 21/12/2020 8:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 30 15.32 436 200 0.20 / 40.02 2 3
2 7 2005.32 30 15.06 2918 1318 1.52 / 41.34 2 3
3 13 1590.00 19 15.07 2410 690 2.21 / 42.03 2 3
4 13 1009.36 19 15.17 1658 478 2.69 / 42.51 2 3
5 13 267.56 19 15.35 660 192 2.88 / 42.70 2 2
6 8 -0.08 165 15.37 256 649 3.53 / 43.35 2 2
Average= 3.33
(KJ/cycle)

Cycle 11 GMT 11/12/2020 10:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 29 15.32 424 188 0.19 / 36.23 2 2
2 3 1016.92 1 15.38 1732 27 0.22 / 36.25 2 2
3 7 2003.08 30 15.06 2918 1318 1.53 / 37.57 2 2
4 13 1596.12 25 15.05 2420 911 2.44 / 38.48 2 2
5 13 835.08 25 15.19 1423 540 2.98 / 39.02 2 2
6 13 67.16 25 15.37 373 143 3.13 / 39.17 2 2
7 8 0.36 165 15.35 259 656 3.78 / 39.82 2 5
Average= 3.32
(KJ/cycle)

Cycle 10 GMT 1/12/2020 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 15.32 430 191 0.19 / 32.50 2 2
2 7 2008.00 30 15.05 2931 1323 1.51 / 33.82 2 2
3 13 1490.36 25 15.07 2279 859 2.37 / 34.68 2 2
4 13 894.28 25 15.17 1505 571 2.94 / 35.25 2 3
5 13 45.60 25 15.38 336 129 3.07 / 35.38 2 2
6 8 -0.16 165 15.35 260 659 3.73 / 36.04 2 3
Average= 3.28
(KJ/cycle)

Cycle 9 GMT 21/11/2020 15:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 29 15.32 432 192 0.19 / 28.87 2 2
2 7 2007.48 30 15.06 2936 1326 1.52 / 30.20 2 2
3 13 1595.40 25 15.05 2427 913 2.43 / 31.11 2 2
4 13 823.24 25 15.19 1406 534 2.97 / 31.65 2 2
5 8 0.12 165 15.35 261 661 3.63 / 32.31 2 2
Average= 3.23
(KJ/cycle)

Cycle 8 GMT 11/11/2020 17:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 30 15.31 453 208 0.21 / 25.38 2 2
2 7 2009.04 30 15.06 2927 1322 1.53 / 26.70 2 2
3 13 1591.04 18 15.09 2416 656 2.19 / 27.36 2 2
4 13 1008.76 18 15.17 1660 453 2.64 / 27.81 2 2
5 13 301.04 18 15.34 709 196 2.84 / 28.01 2 2
6 8 -0.20 165 15.38 266 675 3.51 / 28.68 2 2
Average= 3.19
(KJ/cycle)

Cycle 7 GMT 1/11/2020 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 15.33 431 198 0.20 / 21.74 2 2
2 7 2006.80 30 15.06 2938 1327 1.53 / 23.07 2 2
3 13 1597.56 18 15.07 2427 658 2.18 / 23.73 2 2
4 13 1042.72 18 15.15 1703 464 2.65 / 24.19 2 2
5 13 601.08 18 15.25 1118 307 2.96 / 24.50 2 2
6 8 0.20 165 15.36 265 672 3.63 / 25.17 2 2
Average= 3.15
(KJ/cycle)

Cycle 6 GMT 22/10/2020 22:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 28 15.33 436 187 0.19 / 18.04 2 2
2 3 1046.64 1 15.35 1751 27 0.21 / 18.06 2 2
3 7 2006.68 38 15.01 2926 1669 1.88 / 19.73 2 2
4 13 1415.40 18 15.12 2194 597 2.48 / 20.33 2 2
5 13 821.60 18 15.22 1415 388 2.87 / 20.72 2 2
6 13 185.88 18 15.37 556 154 3.02 / 20.87 2 2
7 8 0.00 165 15.37 265 672 3.69 / 21.54 2 2
Average= 3.08
(KJ/cycle)

Cycle 5 GMT 13/10/2020 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 26 15.35 431 172 0.17 / 14.34 2 3
2 10 1021.04 2 15.32 1707 52 0.22 / 14.39 2 2
3 3 1038.96 1 15.36 1745 27 0.25 / 14.42 2 2
4 7 2001.88 38 15.01 2920 1666 1.92 / 16.08 2 2
5 13 1380.16 18 15.12 2142 583 2.50 / 16.67 2 2
6 13 787.64 18 15.23 1362 373 2.87 / 17.04 2 2
7 13 183.88 18 15.37 540 149 3.02 / 17.19 2 2
8 8 0.08 165 15.37 260 659 3.68 / 17.85 2 2
Average= 2.97
(KJ/cycle)

Cycle 4 GMT 3/10/2020 3: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 28 15.34 415 178 0.18 / 11.29 2 2
2 7 1512.64 38 15.17 2269 1308 1.49 / 12.60 2 2
3 13 1246.20 18 15.20 1956 535 2.02 / 13.13 2 2
4 13 790.68 18 15.28 1356 373 2.39 / 13.50 2 2
5 8 0.04 165 15.39 261 663 3.06 / 14.17 2 2
Average= 2.83
(KJ/cycle)

Cycle 3 GMT 2/10/2020 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 28 15.32 417 179 0.18 / 8.18 2 2
2 7 1509.76 38 15.16 2265 1305 1.48 / 9.49 2 2
3 13 1249.48 18 15.19 1948 533 2.02 / 10.02 2 2
4 13 657.16 18 15.28 1175 323 2.34 / 10.35 2 2
5 8 0.00 165 15.39 255 648 2.99 / 10.99 2 2
6 14 0.00 30 15.37 255 118 3.10 / 11.11 2 2
Average= 2.78
(KJ/cycle)

Cycle 2 GMT 1/10/2020 3: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 15.27 412 176 0.18 / 4.79 2 2
2 3 1016.56 1 15.32 1719 26 0.20 / 4.82 2 2
3 7 1529.68 74 15.02 2290 2545 2.75 / 7.36 2 2
4 8 0.04 165 15.36 254 644 3.39 / 8.01 2 2
Average= 2.67
(KJ/cycle)

Cycle 1 GMT 30/ 9/2020 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 24 15.48 397 147 0.15 / 1.78 2 3
2 10 1011.24 3 15.32 1682 77 0.22 / 1.86 2 2
3 3 1024.72 1 15.33 1710 26 0.25 / 1.89 2 2
4 7 995.84 74 15.17 1592 1787 2.04 / 3.67 2 2
5 8 0.12 165 15.33 257 650 2.69 / 4.32 2 2
6 14 0.12 75 15.31 254 292 2.98 / 4.61 2 3
Average= 2.31
(KJ/cycle)

Cycle 0 GMT 29/ 9/2020 17: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 145.16 24 15.61 467 175 0.17 / 0.17 2 3
2 7 158.00 74 15.56 477 549 0.72 / 0.72 2 2
3 8 -0.00 240 15.54 244 910 1.63 / 1.63 2 3
Average= 1.63
(KJ/cycle)