SIO Argo Site:
Pump Diagnostics Page   



Serial= 8853 WMO= 5906135

Return

←PreviousNext→

Cycle 47 GMT 27/ 3/2021 22:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 15.41 458 219 0.22 / 198.09 2 2
2 7 2009.00 52 15.28 3144 2498 2.72 / 200.59 2 2
3 13 1044.44 16 15.27 1843 450 3.17 / 201.04 2 3
4 13 486.76 16 15.38 1058 260 3.43 / 201.30 2 2
5 13 45.44 16 15.42 390 96 3.52 / 201.40 2 2
6 8 -0.04 175 15.34 312 838 4.36 / 202.24 2 3
Average= 4.21
(KJ/cycle)

Cycle 46 GMT 18/ 3/2021 1:22:57

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 31 15.35 498 237 0.24 / 193.57 2 2
2 7 2003.32 54 15.29 3128 2583 2.82 / 196.15 2 2
3 13 1027.64 16 15.29 1806 442 3.26 / 196.60 2 3
4 13 463.64 16 15.40 1017 251 3.51 / 196.85 2 2
5 13 81.88 16 15.43 445 110 3.62 / 196.96 2 2
6 8 0.16 175 15.38 306 824 4.45 / 197.78 2 4
7 14 0.16 20 15.35 308 95 4.54 / 197.87 2 4
Average= 4.21
(KJ/cycle)

Cycle 45 GMT 8/ 3/2021 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 31 15.34 465 221 0.22 / 189.18 2 2
2 7 2006.60 53 15.27 3119 2524 2.75 / 191.71 2 2
3 13 1007.72 16 15.29 1787 437 3.18 / 192.15 2 3
4 13 451.28 16 15.39 1010 249 3.43 / 192.39 2 2
5 13 73.64 16 15.44 436 108 3.54 / 192.50 2 2
6 8 0.00 175 15.33 310 832 4.37 / 193.33 2 6
Average= 4.20
(KJ/cycle)

Cycle 44 GMT 26/ 2/2021 6: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 31 15.36 476 227 0.23 / 184.84 2 2
2 7 2004.48 53 15.28 3112 2520 2.75 / 187.36 2 2
3 13 1012.40 16 15.30 1789 438 3.18 / 187.80 2 2
4 13 454.36 16 15.39 1009 248 3.43 / 188.05 2 2
5 13 40.56 16 15.44 377 93 3.53 / 188.14 2 2
6 8 0.08 175 15.34 306 821 4.35 / 188.96 2 3
Average= 4.20
(KJ/cycle)

Cycle 43 GMT 16/ 2/2021 8:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 31 15.34 477 227 0.23 / 180.45 2 2
2 7 2004.36 54 15.30 3130 2586 2.81 / 183.03 2 2
3 13 1021.04 16 15.30 1789 438 3.25 / 183.47 2 3
4 13 454.12 16 15.41 999 246 3.50 / 183.72 2 3
5 13 69.28 16 15.44 421 104 3.60 / 183.82 2 2
6 8 0.08 175 15.34 296 795 4.40 / 184.62 2 5
Average= 4.20
(KJ/cycle)

Cycle 42 GMT 6/ 2/2021 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 31 15.36 484 230 0.23 / 176.09 2 2
2 7 2012.36 53 15.28 3133 2537 2.77 / 178.63 2 2
3 13 1037.92 16 15.29 1822 446 3.21 / 179.07 2 2
4 13 478.00 16 15.41 1037 256 3.47 / 179.33 2 2
5 13 43.68 16 15.44 373 92 3.56 / 179.42 2 2
6 8 0.08 175 15.34 298 800 4.36 / 180.22 2 5
Average= 4.19
(KJ/cycle)

Cycle 41 GMT 27/ 1/2021 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 15.35 451 215 0.21 / 171.66 2 2
2 7 2010.28 52 15.30 3131 2491 2.71 / 174.15 2 2
3 13 1031.48 16 15.31 1817 445 3.15 / 174.59 2 3
4 13 471.36 16 15.41 1031 254 3.40 / 174.85 2 3
5 13 80.56 16 15.44 441 109 3.51 / 174.96 2 2
6 13 14.64 16 15.44 330 82 3.60 / 175.04 2 3
7 8 0.08 175 15.35 305 819 4.41 / 175.86 2 4
Average= 4.19
(KJ/cycle)

Cycle 40 GMT 17/ 1/2021 16: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 31 15.37 486 232 0.23 / 167.32 2 2
2 7 2007.04 53 15.30 3130 2538 2.77 / 169.85 2 2
3 13 1038.52 16 15.31 1826 447 3.22 / 170.30 2 3
4 13 465.40 16 15.43 1019 252 3.47 / 170.55 2 2
5 13 43.64 16 15.47 371 92 3.56 / 170.65 2 2
6 8 0.04 175 15.37 297 799 4.36 / 171.44 2 4
Average= 4.18
(KJ/cycle)

Cycle 39 GMT 7/ 1/2021 18:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 31 15.37 492 234 0.23 / 162.95 2 2
2 7 2004.40 53 15.31 3130 2540 2.77 / 165.49 2 2
3 13 1013.72 16 15.33 1787 438 3.21 / 165.93 2 3
4 13 445.76 16 15.45 982 243 3.46 / 166.17 2 2
5 13 74.92 16 15.47 426 105 3.56 / 166.28 2 2
6 8 0.12 175 15.38 300 807 4.37 / 167.08 2 6
Average= 4.18
(KJ/cycle)

Cycle 38 GMT 28/12/2020 20:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 30 15.28 476 218 0.22 / 158.57 2 2
2 3 1020.24 1 15.53 1878 29 0.25 / 158.60 2 2
3 7 2010.44 52 15.31 3130 2492 2.74 / 161.09 2 2
4 13 1030.80 16 15.34 1812 445 3.18 / 161.54 2 3
5 13 466.16 16 15.44 1018 251 3.44 / 161.79 2 2
6 13 82.64 16 15.47 439 109 3.54 / 161.90 2 2
7 8 0.16 175 15.39 304 819 4.36 / 162.72 2 5
Average= 4.17
(KJ/cycle)

Cycle 37 GMT 18/12/2020 23:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 15.46 459 213 0.21 / 154.14 2 2
2 7 2003.36 53 15.31 3117 2529 2.74 / 156.67 2 2
3 13 1038.00 16 15.33 1820 446 3.19 / 157.11 2 3
4 13 466.72 16 15.44 1015 251 3.44 / 157.36 2 2
5 13 78.04 16 15.49 431 107 3.55 / 157.47 2 2
6 8 -0.08 175 15.38 295 794 4.34 / 158.26 2 2
7 14 -0.08 20 15.33 295 90 4.43 / 158.35 2 7
Average= 4.17
(KJ/cycle)

Cycle 36 GMT 9/12/2020 1:29:10

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 30 15.45 470 218 0.22 / 149.72 2 2
2 7 2005.88 53 15.32 3128 2540 2.76 / 152.26 2 2
3 13 1029.72 16 15.34 1799 442 3.20 / 152.71 2 4
4 13 459.36 16 15.45 1004 248 3.45 / 152.95 2 2
5 13 39.72 16 15.51 364 90 3.54 / 153.04 2 3
6 8 0.12 175 15.46 292 790 4.33 / 153.83 2 2
7 14 0.12 20 15.43 291 90 4.42 / 153.92 2 5
Average= 4.16
(KJ/cycle)

Cycle 35 GMT 29/11/2020 3:39:10

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 30 15.44 465 215 0.22 / 145.30 2 2
2 7 2004.24 53 15.33 3119 2534 2.75 / 147.84 2 2
3 13 1016.84 16 15.34 1787 439 3.19 / 148.27 2 3
4 13 455.40 16 15.45 1001 247 3.44 / 148.52 2 2
5 13 34.80 16 15.51 356 88 3.52 / 148.61 2 2
6 8 -0.16 175 15.46 297 804 4.33 / 149.41 2 3
7 14 -0.16 20 15.43 297 92 4.42 / 149.51 2 5
Average= 4.15
(KJ/cycle)

Cycle 34 GMT 19/11/2020 5:46:49

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 30 15.42 464 215 0.21 / 140.90 2 2
2 7 2010.76 53 15.31 3119 2531 2.75 / 143.43 2 2
3 13 1022.00 16 15.35 1797 441 3.19 / 143.87 2 3
4 13 443.24 16 15.45 985 243 3.43 / 144.12 2 2
5 13 34.44 16 15.50 354 88 3.52 / 144.20 2 2
6 8 0.00 175 15.46 293 793 4.31 / 145.00 2 3
7 14 0.00 20 15.43 293 90 4.40 / 145.09 2 4
Average= 4.15
(KJ/cycle)

Cycle 33 GMT 9/11/2020 7:53:10

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 30 15.44 471 218 0.22 / 136.50 2 2
2 7 2009.72 53 15.31 3123 2534 2.75 / 139.03 2 2
3 13 1027.20 16 15.33 1794 440 3.19 / 139.47 2 3
4 13 453.12 16 15.45 992 245 3.44 / 139.72 2 2
5 13 37.04 16 15.49 351 87 3.52 / 139.81 2 2
6 8 0.04 175 15.45 292 789 4.31 / 140.60 2 3
7 14 0.04 20 15.42 293 90 4.40 / 140.69 2 3
Average= 4.14
(KJ/cycle)

Cycle 32 GMT 30/10/2020 10: 3:23

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 30 15.46 492 228 0.23 / 132.08 2 2
2 7 2012.04 53 15.31 3120 2532 2.76 / 134.61 2 2
3 13 1014.48 16 15.34 1781 437 3.20 / 135.04 2 4
4 13 446.56 16 15.46 991 245 3.44 / 135.29 2 2
5 13 30.40 16 15.51 351 87 3.53 / 135.38 2 2
6 8 0.16 175 15.46 300 812 4.34 / 136.19 2 5
7 14 0.16 20 15.43 302 93 4.43 / 136.28 2 4
Average= 4.13
(KJ/cycle)

Cycle 31 GMT 20/10/2020 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 30 15.46 472 219 0.22 / 127.73 2 2
2 7 2004.80 53 15.33 3117 2533 2.75 / 130.26 2 2
3 13 1004.04 16 15.35 1770 435 3.19 / 130.70 2 3
4 13 448.12 16 15.46 993 246 3.43 / 130.94 2 2
5 13 31.56 16 15.52 359 89 3.52 / 131.03 2 2
6 8 -0.04 175 15.50 301 816 4.34 / 131.85 2 6
Average= 4.12
(KJ/cycle)

Cycle 30 GMT 10/10/2020 14:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 30 15.47 496 230 0.23 / 123.34 2 2
2 7 2008.72 53 15.33 3118 2533 2.76 / 125.87 2 2
3 13 1032.44 16 15.36 1825 449 3.21 / 126.32 2 3
4 13 467.52 16 15.46 1022 253 3.46 / 126.57 2 3
5 13 37.12 16 15.53 374 93 3.56 / 126.67 2 2
6 8 0.00 175 15.49 311 843 4.40 / 127.51 2 7
Average= 4.11
(KJ/cycle)

Cycle 29 GMT 30/ 9/2020 16:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 30 15.46 491 228 0.23 / 119.03 2 2
2 7 2008.04 53 15.35 3125 2542 2.77 / 121.57 2 2
3 13 1018.36 16 15.36 1811 445 3.22 / 122.01 2 3
4 13 444.44 16 15.48 998 247 3.46 / 122.26 2 2
5 8 0.12 175 15.52 312 847 4.31 / 123.11 2 6
Average= 4.10
(KJ/cycle)

Cycle 28 GMT 20/ 9/2020 19:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.48 490 228 0.23 / 114.59 2 2
2 7 2011.32 53 15.34 3129 2544 2.77 / 117.14 2 2
3 13 1023.40 16 15.37 1795 441 3.21 / 117.58 2 3
4 13 590.76 16 15.45 1195 295 3.51 / 117.88 2 3
5 13 59.96 16 15.54 403 100 3.61 / 117.98 2 2
6 8 0.12 175 15.53 303 823 4.43 / 118.80 2 5
Average= 4.10
(KJ/cycle)

Cycle 27 GMT 10/ 9/2020 21:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 29 15.48 500 224 0.22 / 110.23 2 2
2 7 2004.28 53 15.36 3106 2529 2.75 / 112.75 2 2
3 13 1015.40 16 15.39 1790 441 3.19 / 113.20 2 3
4 13 441.28 16 15.50 992 246 3.44 / 113.44 2 2
5 13 31.80 16 15.55 358 89 3.53 / 113.53 2 3
6 8 0.08 175 15.52 308 837 4.37 / 114.37 2 3
Average= 4.08
(KJ/cycle)

Cycle 26 GMT 31/ 8/2020 23:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 29 15.50 494 222 0.22 / 105.83 2 2
2 7 2003.28 53 15.37 3116 2538 2.76 / 108.37 2 2
3 13 1014.60 16 15.39 1791 441 3.20 / 108.81 2 3
4 13 444.92 16 15.50 996 247 3.45 / 109.06 2 2
5 13 16.12 16 15.56 342 85 3.53 / 109.15 2 2
6 8 -0.04 175 15.52 315 856 4.39 / 110.00 2 6
Average= 4.07
(KJ/cycle)

Cycle 25 GMT 22/ 8/2020 2:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 29 15.50 479 215 0.22 / 101.57 2 2
2 7 2002.96 53 15.37 3116 2538 2.75 / 104.11 2 2
3 13 1002.12 16 15.39 1762 434 3.19 / 104.54 2 2
4 13 413.28 16 15.52 938 233 3.42 / 104.77 2 3
5 8 0.20 175 15.54 309 840 4.26 / 105.61 2 4
Average= 4.06
(KJ/cycle)

Cycle 24 GMT 12/ 8/2020 4:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 15.51 475 214 0.21 / 97.23 2 2
2 7 2008.56 53 15.37 3122 2543 2.76 / 99.77 2 2
3 13 1007.00 16 15.39 1771 436 3.19 / 100.21 2 3
4 13 429.68 16 15.52 968 240 3.43 / 100.45 2 2
5 13 57.12 16 15.58 396 99 3.53 / 100.54 2 2
6 8 0.08 175 15.54 297 808 4.34 / 101.35 2 6
Average= 4.05
(KJ/cycle)

Cycle 23 GMT 2/ 8/2020 6:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 29 15.51 466 210 0.21 / 93.00 2 2
2 7 2003.88 53 15.37 3115 2538 2.75 / 95.54 2 2
3 13 1008.56 16 15.41 1770 436 3.18 / 95.97 2 2
4 13 433.00 16 15.52 969 241 3.42 / 96.21 2 2
5 8 0.00 175 15.55 294 800 4.22 / 97.01 2 4
Average= 4.04
(KJ/cycle)

Cycle 22 GMT 23/ 7/2020 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 29 15.49 481 216 0.22 / 88.61 2 2
2 7 2009.64 53 15.38 3128 2550 2.77 / 91.16 2 2
3 13 884.72 16 15.44 1601 396 3.16 / 91.56 2 2
4 13 458.56 16 15.52 1008 250 3.41 / 91.81 2 2
5 13 33.56 16 15.58 360 90 3.50 / 91.90 2 2
6 8 0.08 175 15.56 293 798 4.30 / 92.70 2 3
7 14 0.08 20 15.55 290 90 4.39 / 92.79 2 10
Average= 4.03
(KJ/cycle)

Cycle 21 GMT 13/ 7/2020 11:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 29 15.50 483 217 0.22 / 84.38 2 2
2 7 2003.68 53 15.38 3105 2531 2.75 / 86.91 2 2
3 13 899.92 16 15.43 1630 402 3.15 / 87.31 2 2
4 13 478.88 16 15.51 1037 257 3.41 / 87.57 2 2
5 8 0.20 175 15.55 304 827 4.24 / 88.40 2 2
Average= 4.02
(KJ/cycle)

Cycle 20 GMT 3/ 7/2020 13:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 29 15.51 483 217 0.22 / 80.05 2 2
2 7 2002.36 53 15.38 3113 2538 2.75 / 82.59 2 2
3 13 890.36 16 15.44 1625 401 3.16 / 82.99 2 2
4 13 473.76 16 15.51 1030 256 3.41 / 83.25 2 2
5 13 72.20 16 15.58 414 103 3.52 / 83.35 2 3
6 8 0.04 175 15.56 298 811 4.33 / 84.16 2 4
Average= 4.01
(KJ/cycle)

Cycle 19 GMT 23/ 6/2020 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 29 15.51 478 215 0.21 / 75.82 2 2
2 7 2005.92 53 15.39 3125 2549 2.76 / 78.37 2 2
3 13 1003.28 16 15.42 1771 437 3.20 / 78.81 2 2
4 13 421.64 16 15.54 948 236 3.44 / 79.04 2 2
5 8 0.16 165 15.57 309 794 4.23 / 79.84 2 5
Average= 3.99
(KJ/cycle)

Cycle 18 GMT 13/ 6/2020 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 29 15.53 486 219 0.22 / 71.51 2 2
2 7 2003.24 53 15.39 3118 2543 2.76 / 74.05 2 2
3 13 1003.24 16 15.42 1772 437 3.20 / 74.49 2 2
4 13 417.80 16 15.53 950 236 3.44 / 74.72 2 2
5 13 26.80 16 15.59 355 89 3.52 / 74.81 2 2
6 8 -0.04 165 15.57 310 796 4.32 / 75.61 2 3
Average= 3.98
(KJ/cycle)

Cycle 17 GMT 3/ 6/2020 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 29 15.53 474 213 0.21 / 67.18 2 2
2 7 2005.04 53 15.40 3112 2540 2.75 / 69.72 2 2
3 13 999.08 16 15.43 1769 437 3.19 / 70.16 2 2
4 13 411.48 16 15.54 947 235 3.43 / 70.40 2 2
5 13 52.48 16 15.60 398 99 3.53 / 70.49 2 2
6 8 0.24 165 15.57 308 791 4.32 / 71.29 2 3
Average= 3.96
(KJ/cycle)

Cycle 16 GMT 24/ 5/2020 22:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 29 15.53 454 204 0.20 / 62.93 2 2
2 7 2007.36 53 15.41 3111 2541 2.75 / 65.47 2 2
3 13 992.44 16 15.44 1754 433 3.18 / 65.91 2 2
4 13 290.92 16 15.57 761 190 3.37 / 66.10 2 2
5 13 40.92 16 15.60 382 95 3.46 / 66.19 2 2
6 8 0.08 165 15.57 303 778 4.24 / 66.97 2 3
Average= 3.94
(KJ/cycle)

Cycle 15 GMT 15/ 5/2020 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 29 15.52 466 210 0.21 / 58.70 2 2
2 7 2006.92 53 15.40 3115 2542 2.75 / 61.24 2 2
3 13 994.44 16 15.44 1760 435 3.19 / 61.68 2 2
4 13 296.68 16 15.58 756 188 3.38 / 61.87 2 2
5 13 40.36 16 15.61 366 91 3.47 / 61.96 2 2
6 8 -0.04 165 15.58 299 769 4.24 / 62.73 2 4
Average= 3.92
(KJ/cycle)

Cycle 14 GMT 5/ 5/2020 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 29 15.52 481 216 0.22 / 54.32 2 2
2 7 2005.20 53 15.40 3126 2551 2.77 / 56.87 2 2
3 13 1008.32 16 15.44 1789 442 3.21 / 57.31 2 2
4 13 315.96 16 15.57 800 199 3.41 / 57.51 2 2
5 13 46.80 16 15.60 374 93 3.50 / 57.61 2 2
6 8 0.12 165 15.57 292 750 4.25 / 58.36 2 4
7 14 0.12 30 15.55 292 136 4.39 / 58.49 2 6
Average= 3.90
(KJ/cycle)

Cycle 13 GMT 25/ 4/2020 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 28 15.51 481 209 0.21 / 50.09 2 2
2 7 2002.48 52 15.39 3108 2487 2.70 / 52.58 2 2
3 13 994.16 16 15.43 1751 432 3.13 / 53.01 2 2
4 13 400.52 16 15.55 924 230 3.36 / 53.24 2 2
5 13 54.28 16 15.60 389 97 3.46 / 53.34 2 2
6 8 0.16 165 15.57 298 766 4.22 / 54.10 2 8
Average= 3.86
(KJ/cycle)

Cycle 12 GMT 15/ 4/2020 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 28 15.51 469 204 0.20 / 45.89 2 2
2 7 2003.52 52 15.41 3102 2486 2.69 / 48.38 2 2
3 13 881.40 16 15.46 1602 396 3.09 / 48.78 2 2
4 13 452.48 16 15.54 993 247 3.33 / 49.02 2 2
5 13 42.44 16 15.61 369 92 3.42 / 49.11 2 2
6 8 0.08 165 15.57 299 768 4.19 / 49.88 2 6
Average= 3.84
(KJ/cycle)

Cycle 11 GMT 5/ 4/2020 8:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 28 15.53 455 198 0.20 / 41.67 2 2
2 7 2003.80 53 15.39 3097 2526 2.72 / 44.20 2 2
3 13 964.80 16 15.45 1704 421 3.15 / 44.62 2 2
4 13 381.52 16 15.56 874 218 3.36 / 44.84 2 2
5 13 43.08 16 15.61 368 92 3.45 / 44.93 2 2
6 8 -0.12 165 15.57 296 760 4.22 / 45.69 2 4
Average= 3.81
(KJ/cycle)

Cycle 10 GMT 26/ 3/2020 11:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 28 15.53 460 200 0.20 / 37.47 2 2
2 7 2005.44 52 15.41 3113 2495 2.69 / 39.97 2 2
3 13 997.64 16 15.44 1759 435 3.13 / 40.40 2 2
4 13 407.16 16 15.56 930 232 3.36 / 40.63 2 2
5 13 121.80 16 15.59 487 121 3.48 / 40.75 2 2
6 8 0.16 165 15.58 280 720 4.20 / 41.47 2 4
Average= 3.77
(KJ/cycle)

Cycle 9 GMT 16/ 3/2020 13:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 28 15.53 453 197 0.20 / 33.16 2 2
2 3 1016.12 1 15.63 1836 29 0.23 / 33.19 2 2
3 7 2003.64 53 15.41 3094 2527 2.75 / 35.72 2 2
4 13 990.48 22 15.43 1741 591 3.34 / 36.31 2 2
5 13 219.52 22 15.59 639 219 3.56 / 36.53 2 2
6 8 0.00 165 15.58 289 743 4.31 / 37.27 2 4
Average= 3.73
(KJ/cycle)

Cycle 8 GMT 6/ 3/2020 15:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 28 15.52 471 205 0.20 / 28.90 2 2
2 7 2005.20 53 15.42 3101 2534 2.74 / 31.43 2 2
3 13 885.04 21 15.46 1597 518 3.26 / 31.95 2 2
4 13 152.68 21 15.60 530 174 3.43 / 32.13 2 2
5 13 29.20 21 15.61 337 110 3.54 / 32.24 2 2
6 8 0.00 165 15.58 284 730 4.27 / 32.97 2 6
Average= 3.66
(KJ/cycle)

Cycle 7 GMT 25/ 2/2020 17: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 28 15.53 474 206 0.21 / 24.55 2 2
2 7 2005.16 53 15.42 3108 2540 2.75 / 27.09 2 2
3 13 992.64 21 15.42 1725 559 3.30 / 27.65 2 2
4 13 124.16 21 15.60 495 162 3.47 / 27.81 2 2
5 13 22.12 21 15.60 334 109 3.58 / 27.92 2 2
6 8 0.20 165 15.58 300 771 4.35 / 28.70 2 3
Average= 3.59
(KJ/cycle)

Cycle 6 GMT 15/ 2/2020 18:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 26 15.51 485 196 0.20 / 20.14 2 2
2 10 1004.16 2 15.57 1810 56 0.25 / 20.19 2 2
3 7 2006.24 53 15.42 3111 2542 2.79 / 22.74 2 2
4 13 965.32 18 15.45 1720 478 3.27 / 23.21 2 2
5 13 348.56 18 15.56 849 238 3.51 / 23.45 2 2
6 13 29.68 18 15.61 360 101 3.61 / 23.55 2 2
7 8 0.00 165 15.57 309 794 4.41 / 24.35 2 3
Average= 3.48
(KJ/cycle)

Cycle 5 GMT 5/ 2/2020 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 25 15.54 468 182 0.18 / 15.83 2 2
2 10 1020.72 2 15.57 1832 57 0.24 / 15.89 2 2
3 7 2002.56 53 15.42 3085 2521 2.76 / 18.41 2 2
4 13 844.52 18 15.47 1538 428 3.19 / 18.84 2 2
5 13 264.52 18 15.58 721 202 3.39 / 19.04 2 2
6 13 20.72 18 15.62 343 96 3.49 / 19.14 2 2
7 8 0.04 165 15.58 312 802 4.29 / 19.94 2 6
Average= 3.32
(KJ/cycle)

Cycle 4 GMT 26/ 1/2020 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 26 15.54 475 192 0.19 / 12.38 2 2
2 3 1018.00 1 15.62 1844 29 0.22 / 12.41 2 2
3 7 1523.88 52 15.52 2440 1969 2.19 / 14.38 2 2
4 13 736.44 18 15.52 1375 384 2.57 / 14.77 2 2
5 13 74.36 18 15.62 425 119 2.69 / 14.89 2 2
6 8 0.08 165 15.59 298 767 3.46 / 15.65 2 5
Average= 3.13
(KJ/cycle)

Cycle 3 GMT 25/ 1/2020 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 26 15.54 479 194 0.19 / 8.81 2 2
2 10 1009.68 2 15.58 1813 56 0.25 / 8.87 2 2
3 3 970.12 -1 15.90 4 0 0.06 / 8.87 2 2
4 7 1508.60 53 15.54 2431 2002 2.25 / 10.87 2 2
5 13 733.00 18 15.53 1376 385 2.64 / 11.25 2 2
6 13 129.84 18 15.62 518 146 2.78 / 11.40 2 2
7 8 0.04 165 15.60 309 795 3.58 / 12.19 2 7
Average= 3.05
(KJ/cycle)

Cycle 2 GMT 24/ 1/2020 23:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 26 15.57 473 191 0.19 / 4.94 2 2
2 7 1525.44 74 15.33 2432 2759 2.95 / 7.70 2 2
3 13 96.68 18 15.62 466 131 3.08 / 7.83 2 2
4 8 0.08 165 15.60 304 782 3.86 / 8.62 2 3
Average= 2.87
(KJ/cycle)

Cycle 1 GMT 23/ 1/2020 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 23 15.72 434 157 0.16 / 1.87 2 2
2 10 1016.40 3 15.62 1807 85 0.24 / 1.96 2 2
3 3 1024.64 1 15.65 1858 29 0.27 / 1.98 2 2
4 7 1004.48 74 15.48 1726 1977 2.25 / 3.96 2 2
5 8 0.08 165 15.63 306 789 3.04 / 4.75 2 3
Average= 2.38
(KJ/cycle)

Cycle 0 GMT 23/ 1/2020 13:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 142.08 22 15.85 471 164 0.16 / 0.16 2 2
2 7 154.88 74 15.82 485 568 0.73 / 0.73 2 2
3 8 0.08 240 15.80 259 982 1.71 / 1.71 2 6
Average= 1.71
(KJ/cycle)