SIO Argo Site:
Pump Diagnostics Page   



Serial= 8812 WMO= 5906123

Return

←PreviousNext→

Cycle 189 GMT 21/12/2024 1: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 30 15.12 485 220 0.22 / 794.14 2 2
2 7 2007.08 53 14.97 3152 2501 2.72 / 796.64 2 2
3 13 1034.52 18 14.95 1816 489 3.21 / 797.13 2 3
4 13 318.44 18 15.15 792 216 3.43 / 797.34 2 3
5 13 18.36 18 15.22 326 89 3.51 / 797.43 2 3
6 8 -0.08 165 15.18 286 716 4.23 / 798.15 2 4
Average= 4.20
(KJ/cycle)

Cycle 188 GMT 11/12/2024 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 30 15.12 483 219 0.22 / 789.85 2 2
2 7 2010.52 53 14.97 3168 2514 2.73 / 792.36 2 2
3 13 1021.64 18 14.97 1798 484 3.22 / 792.84 2 3
4 13 442.20 18 15.11 970 264 3.48 / 793.11 2 4
5 13 24.40 18 15.23 334 92 3.57 / 793.20 2 2
6 8 0.20 165 15.19 286 717 4.29 / 793.92 2 3
Average= 4.20
(KJ/cycle)

Cycle 187 GMT 1/12/2024 11:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 30 15.11 478 217 0.22 / 785.60 2 2
2 7 2010.56 52 14.96 3165 2462 2.68 / 788.06 2 2
3 13 1031.24 18 14.96 1824 491 3.17 / 788.55 2 3
4 13 450.04 18 15.08 979 266 3.44 / 788.82 2 3
5 13 27.48 18 15.21 342 94 3.53 / 788.91 2 3
6 8 0.08 165 15.18 286 716 4.25 / 789.63 2 3
Average= 4.20
(KJ/cycle)

Cycle 186 GMT 21/11/2024 16:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 30 15.11 491 223 0.22 / 781.47 2 2
2 7 2007.68 53 14.94 3147 2492 2.71 / 783.96 2 2
3 13 1033.72 18 14.95 1822 490 3.20 / 784.45 2 3
4 13 331.40 18 15.13 809 220 3.43 / 784.67 2 3
5 8 0.16 165 15.18 285 714 4.14 / 785.38 2 3
Average= 4.20
(KJ/cycle)

Cycle 185 GMT 11/11/2024 21:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 30 15.12 482 219 0.22 / 777.30 2 2
2 7 2009.36 53 14.95 3177 2517 2.74 / 779.82 2 2
3 13 1023.04 18 14.96 1806 486 3.22 / 780.30 2 3
4 13 320.04 18 15.14 799 218 3.44 / 780.52 2 3
5 8 -0.16 165 15.19 288 722 4.16 / 781.24 2 2
Average= 4.20
(KJ/cycle)

Cycle 184 GMT 2/11/2024 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 30 15.12 486 220 0.22 / 773.13 2 2
2 7 2008.72 53 14.97 3157 2505 2.73 / 775.63 2 2
3 13 1015.68 18 14.97 1792 483 3.21 / 776.11 2 4
4 13 420.56 18 15.11 938 255 3.46 / 776.37 2 4
5 8 0.08 165 15.20 284 712 4.18 / 777.08 2 3
Average= 4.20
(KJ/cycle)

Cycle 183 GMT 23/10/2024 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 15.13 459 208 0.21 / 768.81 2 2
2 7 2003.36 53 14.97 3148 2498 2.71 / 771.31 2 2
3 13 1015.68 18 14.99 1798 485 3.19 / 771.80 2 3
4 13 427.64 18 15.12 947 258 3.45 / 772.06 2 3
5 8 0.04 165 15.21 286 718 4.17 / 772.77 2 3
6 14 0.04 30 15.18 290 132 4.30 / 772.91 2 3
Average= 4.20
(KJ/cycle)

Cycle 182 GMT 13/10/2024 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 30 15.13 469 213 0.21 / 764.50 2 2
2 7 2009.56 53 14.97 3162 2509 2.72 / 767.01 2 2
3 13 1029.80 18 14.97 1814 489 3.21 / 767.50 2 4
4 13 444.64 18 15.11 970 264 3.47 / 767.76 2 5
5 8 0.40 165 15.19 285 714 4.19 / 768.48 2 2
6 14 0.40 30 15.16 286 130 4.32 / 768.61 2 4
Average= 4.20
(KJ/cycle)

Cycle 181 GMT 3/10/2024 17:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 30 15.13 487 221 0.22 / 760.17 2 2
2 7 2010.72 53 14.98 3163 2511 2.73 / 762.68 2 2
3 13 1030.04 18 14.98 1807 487 3.22 / 763.17 2 3
4 13 447.92 18 15.13 985 268 3.49 / 763.43 2 4
5 8 0.04 165 15.21 288 723 4.21 / 764.16 2 2
6 14 0.04 30 15.17 288 131 4.34 / 764.29 2 3
Average= 4.20
(KJ/cycle)

Cycle 180 GMT 23/ 9/2024 22:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 30 15.14 498 226 0.23 / 756.01 2 2
2 7 2010.96 53 14.98 3158 2507 2.73 / 758.52 2 2
3 13 1032.96 18 14.99 1817 490 3.22 / 759.01 2 3
4 13 326.16 18 15.15 803 219 3.44 / 759.23 2 3
5 8 -0.08 165 15.20 287 720 4.16 / 759.95 2 3
Average= 4.20
(KJ/cycle)

Cycle 179 GMT 14/ 9/2024 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.14 485 220 0.22 / 751.87 2 2
2 7 2008.12 52 14.98 3166 2466 2.69 / 754.34 2 2
3 13 1035.80 18 14.97 1829 493 3.18 / 754.83 2 3
4 13 330.60 18 15.16 814 222 3.40 / 755.05 2 4
5 8 -0.08 165 15.21 291 730 4.13 / 755.78 2 3
Average= 4.20
(KJ/cycle)

Cycle 178 GMT 4/ 9/2024 8:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 30 15.13 460 209 0.21 / 747.67 2 2
2 7 2003.68 53 14.99 3154 2506 2.71 / 750.17 2 2
3 13 1044.80 18 14.98 1837 495 3.21 / 750.67 2 4
4 13 439.60 18 15.11 966 263 3.47 / 750.93 2 3
5 8 0.28 165 15.21 288 723 4.20 / 751.65 2 3
Average= 4.20
(KJ/cycle)

Cycle 177 GMT 25/ 8/2024 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 30 15.12 482 219 0.22 / 743.49 2 2
2 7 2006.76 53 14.98 3158 2507 2.73 / 745.99 2 2
3 13 1012.12 18 14.98 1790 483 3.21 / 746.48 2 4
4 13 423.96 18 15.13 949 258 3.47 / 746.74 2 3
5 8 0.24 165 15.22 287 721 4.19 / 747.46 2 3
Average= 4.20
(KJ/cycle)

Cycle 176 GMT 15/ 8/2024 18: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 30 15.12 482 219 0.22 / 739.38 2 2
2 7 2010.32 52 14.96 3167 2464 2.68 / 741.84 2 2
3 13 1033.72 18 14.97 1816 489 3.17 / 742.33 2 3
4 13 331.96 18 15.14 811 221 3.39 / 742.55 2 4
5 8 0.20 165 15.19 285 714 4.11 / 743.27 2 3
Average= 4.20
(KJ/cycle)

Cycle 175 GMT 5/ 8/2024 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 30 15.11 481 218 0.22 / 735.06 2 2
2 7 2010.68 53 14.97 3157 2505 2.72 / 737.57 2 2
3 13 1013.40 18 14.97 1780 480 3.20 / 738.04 2 3
4 13 423.68 18 15.12 944 257 3.46 / 738.30 2 4
5 8 0.44 165 15.20 290 727 4.19 / 739.03 2 2
6 14 0.44 30 15.17 292 133 4.32 / 739.16 3 3
Average= 4.20
(KJ/cycle)

Cycle 174 GMT 27/ 7/2024 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 30 15.14 477 217 0.22 / 730.86 2 2
2 7 2010.32 53 14.95 3158 2502 2.72 / 733.37 2 2
3 13 1050.80 18 14.97 1837 495 3.21 / 733.86 2 3
4 13 466.52 18 15.10 1001 272 3.49 / 734.13 2 4
5 8 -0.04 165 15.19 283 709 4.20 / 734.84 2 3
Average= 4.20
(KJ/cycle)

Cycle 173 GMT 17/ 7/2024 9: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 30 15.13 484 220 0.22 / 726.53 2 2
2 7 2005.08 53 14.97 3155 2503 2.72 / 729.04 2 2
3 13 1029.60 18 14.98 1817 490 3.21 / 729.53 2 4
4 13 448.24 18 15.13 979 267 3.48 / 729.79 2 4
5 8 -0.04 165 15.20 288 722 4.20 / 730.52 2 2
6 14 -0.04 30 15.18 287 131 4.33 / 730.65 2 2
Average= 4.20
(KJ/cycle)

Cycle 172 GMT 7/ 7/2024 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 30 15.14 482 219 0.22 / 722.34 2 2
2 7 2004.60 53 14.98 3152 2502 2.72 / 724.84 2 2
3 13 1021.08 18 14.99 1803 486 3.21 / 725.33 2 3
4 13 437.72 18 15.12 965 263 3.47 / 725.59 2 4
5 8 0.12 165 15.21 289 725 4.20 / 726.31 2 3
Average= 4.20
(KJ/cycle)

Cycle 171 GMT 27/ 6/2024 18:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 15.14 458 208 0.21 / 718.15 2 3
2 7 2003.64 53 14.99 3156 2507 2.72 / 720.66 2 2
3 13 1018.92 18 15.00 1796 485 3.20 / 721.14 2 3
4 13 439.36 18 15.15 965 263 3.46 / 721.41 2 4
5 8 0.24 165 15.21 284 713 4.18 / 722.12 2 4
Average= 4.20
(KJ/cycle)

Cycle 170 GMT 17/ 6/2024 23:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 30 15.11 462 209 0.21 / 714.00 2 2
2 7 2009.44 52 14.98 3164 2465 2.67 / 716.47 2 2
3 13 1036.76 18 14.96 1823 491 3.16 / 716.96 2 3
4 13 447.20 18 15.11 978 266 3.43 / 717.23 2 4
5 8 0.08 165 15.20 286 717 4.15 / 717.94 2 2
Average= 4.20
(KJ/cycle)

Cycle 169 GMT 8/ 6/2024 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 30 15.12 483 219 0.22 / 709.59 2 2
2 7 2010.48 53 14.97 3167 2513 2.73 / 712.10 2 2
3 13 1026.20 18 14.99 1803 486 3.22 / 712.59 2 3
4 13 431.04 18 15.13 952 259 3.48 / 712.84 2 3
5 13 53.72 18 15.21 386 106 3.58 / 712.95 2 3
6 8 -0.08 165 15.18 285 714 4.30 / 713.66 2 3
7 14 -0.08 30 15.16 286 130 4.43 / 713.79 2 3
Average= 4.20
(KJ/cycle)

Cycle 168 GMT 29/ 5/2024 9:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 15.13 456 207 0.21 / 705.34 2 2
2 7 2008.48 52 14.96 3153 2453 2.66 / 707.80 2 2
3 13 1037.16 18 14.96 1820 490 3.15 / 708.29 2 3
4 13 460.44 18 15.10 996 271 3.42 / 708.56 2 3
5 13 32.68 18 15.22 348 95 3.52 / 708.65 2 2
6 8 -0.04 165 15.18 285 714 4.23 / 709.37 2 3
Average= 4.20
(KJ/cycle)

Cycle 167 GMT 19/ 5/2024 14:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 30 15.12 482 219 0.22 / 701.04 2 2
2 7 2008.20 53 14.96 3151 2498 2.72 / 703.54 2 2
3 13 1026.08 18 14.98 1800 485 3.20 / 704.02 2 3
4 13 442.12 18 15.11 967 263 3.47 / 704.28 2 3
5 8 0.16 165 15.19 288 722 4.19 / 705.01 2 3
6 14 0.16 30 15.16 290 132 4.32 / 705.14 2 4
Average= 4.20
(KJ/cycle)

Cycle 166 GMT 9/ 5/2024 19:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 30 15.11 479 217 0.22 / 696.74 2 2
2 7 2010.64 53 14.98 3162 2510 2.73 / 699.25 2 2
3 13 1027.48 18 14.99 1804 487 3.21 / 699.74 2 4
4 13 431.08 18 15.14 955 260 3.47 / 700.00 2 4
5 13 52.00 18 15.24 383 105 3.58 / 700.10 2 3
6 8 0.08 165 15.21 285 715 4.29 / 700.82 2 3
Average= 4.20
(KJ/cycle)

Cycle 165 GMT 30/ 4/2024 0:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 30 15.13 460 209 0.21 / 692.45 2 2
2 7 2007.28 53 14.96 3151 2498 2.71 / 694.95 2 2
3 13 1036.24 18 14.97 1817 490 3.20 / 695.44 2 3
4 13 444.04 18 15.11 974 265 3.46 / 695.70 2 4
5 13 50.48 18 15.22 382 105 3.57 / 695.81 2 3
6 8 -0.20 165 15.18 286 716 4.28 / 696.52 2 3
Average= 4.20
(KJ/cycle)

Cycle 164 GMT 20/ 4/2024 5:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 30 15.12 476 216 0.22 / 688.16 2 2
2 7 2004.36 53 14.98 3158 2507 2.72 / 690.67 2 2
3 13 1047.24 18 14.98 1834 495 3.22 / 691.16 2 4
4 13 451.64 18 15.11 988 269 3.49 / 691.43 2 3
5 13 30.00 18 15.24 349 96 3.58 / 691.53 2 3
6 8 0.40 165 15.20 285 715 4.30 / 692.24 2 4
Average= 4.20
(KJ/cycle)

Cycle 163 GMT 10/ 4/2024 10:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 30 15.12 477 216 0.22 / 683.77 2 2
2 7 2008.16 52 14.98 3159 2461 2.68 / 686.23 2 2
3 13 1020.60 18 14.98 1795 484 3.16 / 686.72 2 4
4 13 439.04 18 15.13 965 263 3.42 / 686.98 2 3
5 13 55.40 18 15.22 390 107 3.53 / 687.09 2 3
6 8 -0.36 165 15.19 290 727 4.26 / 687.81 2 3
7 14 -0.36 30 15.17 290 132 4.39 / 687.94 2 4
Average= 4.19
(KJ/cycle)

Cycle 162 GMT 31/ 3/2024 15:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 30 15.13 483 219 0.22 / 679.57 2 2
2 7 2003.72 53 14.95 3134 2483 2.70 / 682.05 2 2
3 13 1010.88 18 14.99 1782 481 3.18 / 682.53 2 3
4 13 297.04 18 15.16 758 207 3.39 / 682.74 2 3
5 13 39.48 18 15.23 361 99 3.49 / 682.84 2 3
6 8 0.24 165 15.20 286 717 4.21 / 683.55 2 3
Average= 4.19
(KJ/cycle)

Cycle 161 GMT 21/ 3/2024 20:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 15.13 453 206 0.21 / 675.31 2 2
2 7 2008.12 52 14.98 3167 2467 2.67 / 677.78 2 2
3 13 1033.36 18 14.98 1814 489 3.16 / 678.27 2 3
4 13 446.44 18 15.13 976 266 3.43 / 678.54 2 4
5 13 32.92 18 15.22 348 95 3.52 / 678.63 2 2
6 8 0.00 165 15.19 286 717 4.24 / 679.35 2 4
Average= 4.19
(KJ/cycle)

Cycle 160 GMT 12/ 3/2024 1: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 30 15.14 479 218 0.22 / 671.04 2 2
2 7 2008.04 53 14.98 3167 2514 2.73 / 673.55 2 2
3 13 1018.68 18 14.99 1796 485 3.22 / 674.04 2 3
4 13 440.76 18 15.14 964 263 3.48 / 674.30 2 4
5 13 30.36 18 15.24 349 96 3.58 / 674.40 2 2
6 8 -0.04 165 15.19 284 712 4.29 / 675.11 2 3
Average= 4.19
(KJ/cycle)

Cycle 159 GMT 2/ 3/2024 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 15.14 447 203 0.20 / 666.84 2 2
2 7 2007.04 52 14.99 3166 2468 2.67 / 669.31 2 2
3 13 1025.04 18 15.00 1806 488 3.16 / 669.79 2 4
4 13 311.80 18 15.18 780 213 3.37 / 670.01 2 3
5 13 34.80 18 15.25 356 98 3.47 / 670.11 2 2
6 8 0.28 165 15.22 285 716 4.19 / 670.82 2 4
Average= 4.19
(KJ/cycle)

Cycle 158 GMT 21/ 2/2024 10:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 30 15.12 466 211 0.21 / 662.44 2 3
2 7 2009.72 53 14.98 3162 2510 2.72 / 664.95 2 2
3 13 1017.16 18 15.00 1793 484 3.21 / 665.44 2 3
4 13 427.92 18 15.14 949 259 3.46 / 665.70 2 4
5 13 29.16 18 15.24 344 94 3.56 / 665.79 2 3
6 8 0.08 165 15.19 286 717 4.28 / 666.51 2 6
7 14 0.08 30 15.16 284 129 4.40 / 666.64 2 4
Average= 4.19
(KJ/cycle)

Cycle 157 GMT 11/ 2/2024 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 15.12 459 208 0.21 / 658.17 2 2
2 7 2008.12 53 14.97 3154 2502 2.71 / 660.67 2 2
3 13 1020.32 18 15.00 1795 485 3.20 / 661.15 2 3
4 13 438.68 18 15.12 962 262 3.46 / 661.42 2 3
5 13 25.32 18 15.23 336 92 3.55 / 661.51 2 3
6 8 0.12 165 15.21 288 723 4.27 / 662.23 2 4
Average= 4.19
(KJ/cycle)

Cycle 156 GMT 1/ 2/2024 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 30 15.12 467 212 0.21 / 653.92 2 2
2 7 2012.52 52 14.97 3169 2467 2.68 / 656.39 2 2
3 13 1033.28 18 14.98 1815 489 3.17 / 656.88 2 3
4 13 450.04 18 15.13 979 267 3.43 / 657.14 2 4
5 13 28.56 18 15.23 341 93 3.53 / 657.24 2 3
6 8 -0.12 165 15.20 288 722 4.25 / 657.96 2 2
Average= 4.19
(KJ/cycle)

Cycle 155 GMT 22/ 1/2024 22:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 30 15.13 479 217 0.22 / 649.55 2 2
2 7 2010.44 53 14.99 3160 2511 2.73 / 652.06 2 2
3 13 1022.56 18 14.99 1805 487 3.21 / 652.55 2 4
4 13 309.80 18 15.18 777 212 3.43 / 652.76 2 3
5 13 37.96 18 15.25 361 99 3.53 / 652.86 2 3
6 8 -0.08 165 15.22 286 718 4.24 / 653.58 2 3
7 14 -0.08 30 15.19 288 131 4.38 / 653.71 2 3
Average= 4.19
(KJ/cycle)

Cycle 154 GMT 13/ 1/2024 0:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 30 15.14 458 208 0.21 / 645.25 2 2
2 7 2006.00 53 14.99 3160 2511 2.72 / 647.76 2 2
3 13 1026.68 18 14.99 1808 488 3.21 / 648.25 2 4
4 13 426.76 18 15.14 947 258 3.46 / 648.51 2 4
5 13 29.92 18 15.25 352 97 3.56 / 648.60 2 3
6 8 -0.04 165 15.21 291 730 4.29 / 649.33 2 2
Average= 4.19
(KJ/cycle)

Cycle 153 GMT 3/ 1/2024 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 30 15.14 481 218 0.22 / 640.97 2 3
2 7 2004.76 53 14.99 3159 2510 2.73 / 643.48 2 2
3 13 1022.52 18 14.99 1802 486 3.21 / 643.97 2 3
4 13 431.68 18 15.15 955 260 3.47 / 644.23 2 3
5 13 29.44 18 15.24 347 95 3.57 / 644.32 2 2
6 8 0.16 165 15.20 287 720 4.29 / 645.04 2 4
Average= 4.19
(KJ/cycle)

Cycle 152 GMT 24/12/2023 5:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 15.15 460 209 0.21 / 636.67 2 2
2 7 2009.08 53 15.00 3157 2510 2.72 / 639.17 2 2
3 13 1036.80 18 14.98 1821 491 3.21 / 639.67 2 3
4 13 454.24 18 15.14 988 269 3.48 / 639.94 2 3
5 13 15.76 18 15.26 324 89 3.57 / 640.02 2 2
6 8 -0.20 165 15.21 290 728 4.30 / 640.75 2 3
Average= 4.19
(KJ/cycle)

Cycle 151 GMT 14/12/2023 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 30 15.15 491 223 0.22 / 632.36 2 2
2 7 2010.92 53 14.99 3167 2516 2.74 / 634.88 2 2
3 13 1034.92 18 15.00 1825 493 3.23 / 635.37 2 4
4 13 435.48 18 15.15 958 261 3.49 / 635.63 2 4
5 13 24.84 18 15.25 345 95 3.59 / 635.73 2 2
6 8 0.12 165 15.22 290 728 4.32 / 636.46 2 2
Average= 4.19
(KJ/cycle)

Cycle 150 GMT 4/12/2023 10:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 30 15.16 495 225 0.23 / 628.05 2 2
2 7 2009.24 53 14.99 3169 2518 2.74 / 630.56 2 2
3 13 1029.92 18 15.00 1817 491 3.23 / 631.06 2 3
4 13 439.08 18 15.14 965 263 3.50 / 631.32 2 5
5 13 26.20 18 15.26 346 95 3.59 / 631.41 2 2
6 8 -0.04 165 15.23 289 726 4.32 / 632.14 2 3
Average= 4.19
(KJ/cycle)

Cycle 149 GMT 24/11/2023 12:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 30 15.16 484 220 0.22 / 623.82 2 3
2 7 2011.04 53 14.99 3161 2511 2.73 / 626.33 2 2
3 13 1021.96 18 14.99 1803 486 3.22 / 626.82 2 3
4 13 446.76 18 15.14 981 267 3.49 / 627.09 2 4
5 8 0.24 165 15.22 293 736 4.22 / 627.82 2 2
Average= 4.19
(KJ/cycle)

Cycle 148 GMT 14/11/2023 15:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 30 15.17 493 224 0.22 / 619.51 2 2
2 7 2005.44 52 14.99 3169 2470 2.69 / 621.98 2 2
3 13 1024.52 18 15.01 1810 489 3.18 / 622.47 2 4
4 13 443.24 18 15.15 973 265 3.45 / 622.74 2 4
5 8 0.00 165 15.24 291 732 4.18 / 623.47 2 3
6 14 0.00 30 15.22 291 133 4.31 / 623.60 2 3
Average= 4.19
(KJ/cycle)

Cycle 147 GMT 4/11/2023 17:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 30 15.16 495 225 0.23 / 615.29 2 3
2 7 2004.12 53 14.99 3171 2519 2.74 / 617.81 2 2
3 13 1013.28 18 15.02 1799 486 3.23 / 618.30 2 3
4 13 421.64 18 15.16 944 258 3.49 / 618.55 2 3
5 8 0.16 165 15.24 292 734 4.22 / 619.29 2 3
Average= 4.18
(KJ/cycle)

Cycle 146 GMT 25/10/2023 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 30 15.15 484 220 0.22 / 611.11 2 2
2 7 2006.96 53 15.00 3161 2513 2.73 / 613.63 2 2
3 13 1030.24 18 15.01 1812 490 3.22 / 614.12 2 3
4 13 314.36 18 15.19 789 216 3.44 / 614.33 2 3
5 8 0.12 165 15.23 292 734 4.17 / 615.06 2 3
Average= 4.18
(KJ/cycle)

Cycle 145 GMT 15/10/2023 22:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 30 15.17 500 228 0.23 / 606.77 2 2
2 7 2004.52 53 15.00 3156 2509 2.74 / 609.28 2 2
3 13 1021.44 18 14.99 1799 485 3.22 / 609.77 2 3
4 13 437.88 18 15.14 966 263 3.49 / 610.03 2 3
5 8 0.24 165 15.22 290 728 4.21 / 610.76 2 2
6 14 0.24 30 15.20 291 133 4.35 / 610.89 2 3
Average= 4.18
(KJ/cycle)

Cycle 144 GMT 6/10/2023 0:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 30 15.16 486 221 0.22 / 602.42 2 4
2 7 2009.64 53 14.98 3164 2512 2.73 / 604.93 2 2
3 13 1022.24 18 15.00 1805 487 3.22 / 605.42 2 4
4 13 429.48 18 15.15 954 260 3.48 / 605.68 2 4
5 8 -0.04 165 15.23 292 734 4.21 / 606.41 2 3
6 14 -0.04 30 15.20 296 135 4.35 / 606.55 2 4
Average= 4.18
(KJ/cycle)

Cycle 143 GMT 26/ 9/2023 2:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 30 15.16 496 226 0.23 / 598.20 2 2
2 7 2005.64 53 15.01 3163 2516 2.74 / 600.72 2 2
3 13 1029.28 18 15.00 1812 489 3.23 / 601.21 2 3
4 13 438.48 18 15.15 963 263 3.49 / 601.47 2 4
5 8 -0.04 165 15.22 290 728 4.22 / 602.20 2 2
Average= 4.18
(KJ/cycle)

Cycle 142 GMT 16/ 9/2023 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 30 15.17 491 223 0.22 / 593.98 2 2
2 7 2007.68 53 14.99 3168 2517 2.74 / 596.50 2 2
3 13 1022.72 18 15.01 1796 485 3.23 / 596.98 2 3
4 13 424.40 18 15.17 945 258 3.48 / 597.24 2 4
5 8 0.56 165 15.24 292 734 4.22 / 597.98 2 3
Average= 4.18
(KJ/cycle)

Cycle 141 GMT 6/ 9/2023 7:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 30 15.16 480 218 0.22 / 589.68 2 2
2 7 2007.68 52 14.99 3151 2456 2.67 / 592.14 2 2
3 13 1036.68 18 15.02 1822 493 3.17 / 592.63 2 3
4 13 451.28 18 15.16 985 269 3.44 / 592.90 2 4
5 8 -0.16 165 15.24 289 727 4.16 / 593.62 2 3
6 14 -0.16 30 15.22 292 133 4.30 / 593.76 2 3
Average= 4.18
(KJ/cycle)

Cycle 140 GMT 27/ 8/2023 10: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 30 15.16 465 211 0.21 / 585.34 2 2
2 7 2006.28 53 15.01 3155 2510 2.72 / 587.85 2 2
3 13 1037.16 18 14.99 1817 490 3.21 / 588.34 2 3
4 13 451.48 18 15.15 981 268 3.48 / 588.60 2 4
5 8 0.24 165 15.23 289 726 4.21 / 589.33 2 2
6 14 0.24 30 15.21 289 132 4.34 / 589.46 2 4
Average= 4.18
(KJ/cycle)

Cycle 139 GMT 17/ 8/2023 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 30 15.15 474 215 0.22 / 580.95 2 2
2 7 2006.60 52 15.00 3167 2470 2.69 / 583.42 2 2
3 13 1014.16 18 15.02 1792 484 3.17 / 583.91 2 3
4 13 436.76 18 15.16 964 263 3.43 / 584.17 2 3
5 13 29.36 18 15.26 343 94 3.53 / 584.26 2 2
6 8 0.20 165 15.23 290 729 4.26 / 584.99 2 3
7 14 0.20 30 15.21 291 133 4.39 / 585.12 2 3
Average= 4.18
(KJ/cycle)

Cycle 138 GMT 7/ 8/2023 14:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 30 15.15 479 218 0.22 / 576.65 2 2
2 7 2008.40 53 15.00 3163 2515 2.73 / 579.16 2 2
3 13 1033.32 18 15.01 1818 491 3.22 / 579.65 2 4
4 13 444.88 18 15.16 971 265 3.49 / 579.92 2 4
5 13 25.44 18 15.26 336 92 3.58 / 580.01 2 2
6 8 -0.08 165 15.22 288 723 4.30 / 580.74 2 3
Average= 4.18
(KJ/cycle)

Cycle 137 GMT 28/ 7/2023 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 30 15.17 483 220 0.22 / 572.41 2 2
2 7 2006.44 52 15.01 3162 2468 2.69 / 574.87 2 2
3 13 1029.72 18 15.00 1811 489 3.18 / 575.36 2 3
4 13 330.88 18 15.18 807 221 3.40 / 575.58 2 3
5 8 0.16 165 15.23 286 719 4.12 / 576.30 2 3
6 14 0.16 30 15.20 285 130 4.25 / 576.43 2 4
Average= 4.18
(KJ/cycle)

Cycle 136 GMT 18/ 7/2023 19: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 30 15.16 484 220 0.22 / 568.21 2 2
2 7 2008.60 53 15.00 3155 2508 2.73 / 570.72 2 2
3 13 1030.96 18 15.01 1812 490 3.22 / 571.20 2 3
4 13 427.28 18 15.16 948 259 3.48 / 571.46 2 4
5 8 -0.08 165 15.24 287 722 4.20 / 572.19 2 2
Average= 4.18
(KJ/cycle)

Cycle 135 GMT 8/ 7/2023 21:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 30 15.17 484 220 0.22 / 563.96 2 2
2 7 2005.28 52 14.99 3164 2466 2.69 / 566.42 2 2
3 13 1035.12 18 15.00 1822 492 3.18 / 566.92 2 3
4 13 317.20 18 15.18 791 216 3.39 / 567.13 2 4
5 8 0.04 165 15.23 288 724 4.12 / 567.86 2 3
6 14 0.04 30 15.20 286 130 4.25 / 567.99 2 4
Average= 4.18
(KJ/cycle)

Cycle 134 GMT 28/ 6/2023 23:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 15.17 454 207 0.21 / 559.52 2 3
2 7 2005.92 53 15.01 3151 2507 2.71 / 562.03 2 2
3 13 1025.84 18 15.03 1810 490 3.20 / 562.52 2 3
4 13 434.56 18 15.17 958 262 3.46 / 562.78 2 4
5 13 54.68 18 15.26 391 107 3.57 / 562.88 2 3
6 8 0.24 165 15.23 287 721 4.29 / 563.61 2 6
7 14 0.24 30 15.21 290 132 4.43 / 563.74 3 3
Average= 4.18
(KJ/cycle)

Cycle 133 GMT 19/ 6/2023 2:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 15.17 465 212 0.21 / 555.28 2 2
2 7 2002.48 53 15.00 3137 2494 2.71 / 557.77 2 2
3 13 1019.40 18 15.01 1794 485 3.19 / 558.26 2 4
4 13 310.20 18 15.19 778 213 3.40 / 558.47 2 3
5 8 0.08 165 15.22 284 713 4.12 / 559.18 2 3
6 14 0.08 30 15.20 284 130 4.25 / 559.31 2 3
Average= 4.17
(KJ/cycle)

Cycle 132 GMT 9/ 6/2023 4:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 30 15.18 471 214 0.21 / 550.84 2 2
2 7 2011.64 53 15.02 3167 2521 2.74 / 553.36 2 2
3 13 1025.88 18 15.02 1805 488 3.22 / 553.85 2 4
4 13 433.00 18 15.17 953 260 3.48 / 554.11 2 4
5 13 58.96 18 15.27 396 109 3.59 / 554.22 2 3
6 8 0.20 165 15.25 285 717 4.31 / 554.94 2 3
7 14 0.20 30 15.22 286 131 4.44 / 555.07 2 4
Average= 4.17
(KJ/cycle)

Cycle 131 GMT 30/ 5/2023 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 30 15.17 460 209 0.21 / 546.49 2 2
2 7 2007.96 52 15.02 3174 2479 2.69 / 548.97 2 2
3 13 1023.68 18 15.03 1802 488 3.18 / 549.45 2 3
4 13 314.40 18 15.20 790 216 3.39 / 549.67 2 4
5 13 34.36 18 15.27 357 98 3.49 / 549.77 2 3
6 8 0.16 165 15.23 289 726 4.22 / 550.49 2 5
7 14 0.16 30 15.21 289 132 4.35 / 550.63 2 5
Average= 4.17
(KJ/cycle)

Cycle 130 GMT 20/ 5/2023 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 30 15.15 471 214 0.21 / 542.25 2 2
2 7 2005.80 52 15.01 3152 2460 2.67 / 544.71 2 2
3 13 1022.96 18 15.04 1802 488 3.16 / 545.20 2 3
4 13 432.84 18 15.16 952 260 3.42 / 545.46 2 3
5 13 49.84 18 15.26 379 104 3.53 / 545.56 2 3
6 8 0.28 165 15.23 286 719 4.24 / 546.28 2 2
Average= 4.17
(KJ/cycle)

Cycle 129 GMT 10/ 5/2023 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 30 15.16 486 221 0.22 / 537.89 2 2
2 7 2007.20 53 15.00 3149 2503 2.72 / 540.40 2 2
3 13 1021.12 18 15.02 1801 487 3.21 / 540.88 2 3
4 13 304.20 18 15.20 766 210 3.42 / 541.09 2 3
5 13 35.28 18 15.27 354 97 3.52 / 541.19 2 3
6 8 -0.12 165 15.24 284 714 4.23 / 541.90 2 3
7 14 -0.12 30 15.21 285 130 4.36 / 542.03 2 3
Average= 4.17
(KJ/cycle)

Cycle 128 GMT 30/ 4/2023 13:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 30 15.16 478 217 0.22 / 533.60 2 2
2 7 2005.84 53 15.00 3149 2503 2.72 / 536.10 2 2
3 13 1014.96 18 15.03 1789 484 3.20 / 536.59 2 3
4 13 418.72 18 15.18 936 256 3.46 / 536.84 2 4
5 13 51.88 18 15.27 385 106 3.57 / 536.95 2 3
6 8 0.20 165 15.23 287 721 4.29 / 537.67 2 3
Average= 4.17
(KJ/cycle)

Cycle 127 GMT 20/ 4/2023 16:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 30 15.16 479 218 0.22 / 529.41 2 2
2 7 2003.76 52 15.00 3148 2455 2.67 / 531.87 2 2
3 13 1022.28 18 15.01 1799 486 3.16 / 532.35 2 4
4 13 305.84 18 15.20 771 211 3.37 / 532.56 2 3
5 13 38.12 18 15.27 361 99 3.47 / 532.66 2 2
6 8 0.08 165 15.24 287 722 4.19 / 533.38 2 3
Average= 4.17
(KJ/cycle)

Cycle 126 GMT 10/ 4/2023 18:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 15.17 461 210 0.21 / 524.98 2 2
2 7 2011.00 53 15.00 3179 2527 2.74 / 527.51 2 2
3 13 1013.52 18 15.04 1788 484 3.22 / 527.99 2 3
4 13 427.20 18 15.16 949 259 3.48 / 528.25 2 4
5 13 23.32 18 15.27 336 92 3.57 / 528.34 2 3
6 8 0.04 165 15.24 286 719 4.29 / 529.06 2 3
7 14 0.04 30 15.22 286 131 4.42 / 529.19 2 4
Average= 4.17
(KJ/cycle)

Cycle 125 GMT 31/ 3/2023 20:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 30 15.16 457 208 0.21 / 520.73 2 2
2 7 2011.76 53 15.00 3170 2520 2.73 / 523.25 2 2
3 13 1026.76 18 15.03 1809 489 3.22 / 523.74 2 3
4 13 313.28 18 15.21 784 215 3.43 / 523.95 2 4
5 13 33.32 18 15.28 352 97 3.53 / 524.05 2 3
6 8 -0.04 165 15.25 286 720 4.25 / 524.77 2 3
Average= 4.16
(KJ/cycle)

Cycle 124 GMT 21/ 3/2023 23:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 30 15.17 480 218 0.22 / 516.50 2 2
2 7 2004.52 53 15.00 3159 2511 2.73 / 519.01 2 2
3 13 1017.80 18 15.01 1798 486 3.22 / 519.50 2 3
4 13 309.36 18 15.20 777 213 3.43 / 519.71 2 4
5 13 33.08 18 15.27 353 97 3.53 / 519.81 2 3
6 8 0.28 165 15.23 285 716 4.24 / 520.52 2 4
Average= 4.16
(KJ/cycle)

Cycle 123 GMT 12/ 3/2023 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 30 15.19 474 216 0.22 / 512.22 2 2
2 7 2008.16 53 15.00 3154 2507 2.72 / 514.73 2 2
3 13 1018.84 18 15.02 1800 487 3.21 / 515.21 2 4
4 13 419.40 18 15.18 937 256 3.47 / 515.47 2 4
5 13 28.68 18 15.27 345 95 3.56 / 515.56 2 3
6 8 -0.12 165 15.24 285 717 4.28 / 516.28 2 2
Average= 4.16
(KJ/cycle)

Cycle 122 GMT 2/ 3/2023 4: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 30 15.17 474 216 0.22 / 507.93 2 2
2 7 2006.52 53 15.02 3150 2508 2.72 / 510.44 2 2
3 13 1030.48 18 15.02 1815 491 3.21 / 510.93 2 3
4 13 434.64 18 15.17 960 262 3.48 / 511.19 2 4
5 13 26.52 18 15.27 345 95 3.57 / 511.28 2 3
6 8 0.08 165 15.24 286 719 4.29 / 512.00 2 3
Average= 4.16
(KJ/cycle)

Cycle 121 GMT 20/ 2/2023 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 30 15.17 486 221 0.22 / 503.70 2 2
2 7 2011.84 52 15.00 3181 2481 2.70 / 506.19 2 2
3 13 1026.44 18 15.03 1808 489 3.19 / 506.67 2 4
4 13 321.36 18 15.21 794 217 3.41 / 506.89 2 3
5 13 36.28 18 15.27 359 99 3.51 / 506.99 2 3
6 8 -0.16 165 15.24 287 722 4.23 / 507.71 2 3
Average= 4.16
(KJ/cycle)

Cycle 120 GMT 10/ 2/2023 8:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 30 15.18 461 210 0.21 / 499.47 2 2
2 7 2007.32 53 15.02 3142 2501 2.71 / 501.97 2 2
3 13 1014.92 18 15.03 1791 485 3.20 / 502.45 2 4
4 13 307.20 18 15.22 778 213 3.41 / 502.67 2 3
5 13 29.96 18 15.28 346 95 3.50 / 502.76 2 3
6 8 0.24 165 15.25 287 722 4.23 / 503.48 2 4
Average= 4.16
(KJ/cycle)

Cycle 119 GMT 31/ 1/2023 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 30 15.18 481 219 0.22 / 495.15 2 2
2 7 2007.88 53 15.02 3177 2529 2.75 / 497.68 2 2
3 13 1027.00 18 15.04 1807 489 3.24 / 498.17 2 3
4 13 435.72 18 15.19 961 263 3.50 / 498.43 2 4
5 13 48.88 18 15.29 381 105 3.60 / 498.54 2 3
6 8 -0.04 165 15.24 287 722 4.33 / 499.26 2 3
Average= 4.16
(KJ/cycle)

Cycle 118 GMT 21/ 1/2023 13:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 30 15.18 486 221 0.22 / 490.86 2 2
2 7 2003.96 53 15.02 3155 2512 2.73 / 493.37 2 2
3 13 1014.84 18 15.04 1798 487 3.22 / 493.86 2 4
4 13 432.28 18 15.18 951 260 3.48 / 494.12 2 4
5 13 26.00 18 15.30 339 93 3.57 / 494.21 2 3
6 8 0.04 165 15.25 285 717 4.29 / 494.93 2 5
Average= 4.16
(KJ/cycle)

Cycle 117 GMT 11/ 1/2023 16:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 30 15.18 472 215 0.21 / 486.57 2 2
2 7 2004.20 53 15.02 3149 2507 2.72 / 489.08 2 2
3 13 1022.28 18 15.04 1805 489 3.21 / 489.57 2 3
4 13 427.52 18 15.19 948 259 3.47 / 489.83 2 4
5 13 25.36 18 15.29 336 92 3.56 / 489.92 2 2
6 8 0.08 165 15.26 286 720 4.28 / 490.64 2 4
Average= 4.16
(KJ/cycle)

Cycle 116 GMT 1/ 1/2023 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 30 15.19 467 213 0.21 / 482.36 2 2
2 7 2010.00 53 15.02 3159 2515 2.73 / 484.88 2 2
3 13 1039.88 18 15.02 1826 494 3.22 / 485.37 2 3
4 13 440.96 18 15.18 964 263 3.48 / 485.64 2 5
5 8 0.20 165 15.26 287 723 4.21 / 486.36 2 3
Average= 4.16
(KJ/cycle)

Cycle 115 GMT 22/12/2022 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 30 15.17 477 217 0.22 / 478.01 2 2
2 7 2003.96 52 15.04 3146 2460 2.68 / 480.47 2 2
3 13 1025.52 18 15.03 1804 488 3.17 / 480.96 2 3
4 13 426.12 18 15.17 946 258 3.42 / 481.21 2 4
5 13 23.04 18 15.27 334 92 3.52 / 481.31 2 3
6 8 -0.08 165 15.24 284 714 4.23 / 482.02 2 7
7 14 -0.08 30 15.22 285 130 4.36 / 482.15 2 4
Average= 4.16
(KJ/cycle)

Cycle 114 GMT 12/12/2022 23:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 30 15.20 483 220 0.22 / 473.76 2 2
2 7 2012.00 53 15.02 3154 2511 2.73 / 476.27 2 2
3 13 1027.00 18 15.04 1807 489 3.22 / 476.76 2 3
4 13 330.88 18 15.21 810 222 3.44 / 476.98 2 3
5 13 33.72 18 15.29 348 96 3.54 / 477.07 2 3
6 8 0.12 165 15.24 285 717 4.25 / 477.79 2 3
Average= 4.15
(KJ/cycle)

Cycle 113 GMT 3/12/2022 1:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 30 15.18 484 220 0.22 / 469.60 2 2
2 7 2004.12 53 15.03 3176 2530 2.75 / 472.12 2 2
3 13 1011.36 18 15.05 1786 484 3.23 / 472.61 2 4
4 13 305.76 18 15.24 772 212 3.45 / 472.82 2 3
5 8 -0.04 165 15.28 284 716 4.16 / 473.54 2 4
Average= 4.15
(KJ/cycle)

Cycle 112 GMT 23/11/2022 3:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 30 15.18 484 220 0.22 / 465.18 2 2
2 7 2005.72 53 15.02 3155 2512 2.73 / 467.69 2 2
3 13 1032.48 18 15.04 1820 493 3.22 / 468.18 2 4
4 13 426.40 18 15.19 946 259 3.48 / 468.44 2 4
5 13 24.28 18 15.28 333 92 3.57 / 468.53 2 2
6 8 0.04 165 15.24 283 712 4.29 / 469.24 2 3
7 14 0.04 30 15.22 284 130 4.42 / 469.37 2 4
Average= 4.15
(KJ/cycle)

Cycle 111 GMT 13/11/2022 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 30 15.19 465 212 0.21 / 461.04 2 2
2 7 2006.24 53 15.00 3154 2507 2.72 / 463.55 2 2
3 13 1018.28 18 15.02 1789 484 3.20 / 464.03 2 3
4 13 299.92 18 15.22 762 209 3.41 / 464.24 2 3
5 8 0.08 165 15.25 284 715 4.13 / 464.96 2 3
Average= 4.15
(KJ/cycle)

Cycle 110 GMT 3/11/2022 8:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 15.21 463 211 0.21 / 456.73 2 2
2 7 2006.80 53 15.01 3164 2517 2.73 / 459.24 2 2
3 13 1008.28 18 15.05 1785 484 3.21 / 459.73 2 3
4 13 426.28 18 15.18 944 258 3.47 / 459.98 2 3
5 8 0.24 165 15.27 285 718 4.19 / 460.70 2 3
6 14 0.24 30 15.24 285 130 4.32 / 460.83 2 2
Average= 4.15
(KJ/cycle)

Cycle 109 GMT 24/10/2022 10:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 30 15.20 458 209 0.21 / 452.55 2 2
2 7 2005.36 53 15.03 3156 2514 2.72 / 455.06 2 2
3 13 1003.44 18 15.04 1769 479 3.20 / 455.54 2 4
4 13 413.60 18 15.19 923 252 3.45 / 455.79 2 4
5 8 -0.12 165 15.27 287 723 4.18 / 456.51 2 2
Average= 4.15
(KJ/cycle)

Cycle 108 GMT 14/10/2022 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 30 15.19 465 212 0.21 / 448.41 2 2
2 7 2010.96 53 15.02 3162 2517 2.73 / 450.92 2 2
3 13 1015.40 18 15.03 1789 484 3.21 / 451.41 2 4
4 13 301.64 18 15.22 762 209 3.42 / 451.62 2 3
5 8 0.00 165 15.26 286 720 4.14 / 452.34 2 3
Average= 4.15
(KJ/cycle)

Cycle 107 GMT 4/10/2022 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 30 15.21 486 222 0.22 / 444.14 2 2
2 7 2004.20 53 15.00 3153 2507 2.73 / 446.65 2 2
3 13 1017.40 18 15.03 1791 485 3.21 / 447.13 2 3
4 13 310.12 18 15.22 772 211 3.42 / 447.35 2 3
5 8 0.20 165 15.26 285 718 4.14 / 448.06 2 3
6 14 0.20 30 15.24 287 131 4.27 / 448.19 2 2
Average= 4.15
(KJ/cycle)

Cycle 106 GMT 24/ 9/2022 17:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 30 15.21 493 225 0.22 / 440.00 2 2
2 7 2005.04 52 15.03 3172 2479 2.70 / 442.48 2 2
3 13 1027.28 18 15.07 1806 490 3.19 / 442.97 2 4
4 13 325.08 18 15.22 794 218 3.41 / 443.19 2 4
5 8 0.00 165 15.28 290 731 4.14 / 443.92 2 4
Average= 4.15
(KJ/cycle)

Cycle 105 GMT 14/ 9/2022 20:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 30 15.21 483 220 0.22 / 435.84 2 2
2 7 2008.92 53 15.02 3154 2511 2.73 / 438.35 2 2
3 13 1022.84 18 15.04 1805 489 3.22 / 438.84 2 4
4 13 326.68 18 15.23 806 221 3.44 / 439.06 2 3
5 8 0.16 165 15.28 286 721 4.16 / 439.78 2 3
Average= 4.15
(KJ/cycle)

Cycle 104 GMT 4/ 9/2022 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 30 15.21 487 222 0.22 / 431.68 2 3
2 7 2004.16 53 15.01 3155 2510 2.73 / 434.19 2 2
3 13 1029.84 18 15.05 1812 491 3.22 / 434.68 2 3
4 13 315.56 18 15.23 786 215 3.44 / 434.90 2 3
5 8 0.48 165 15.27 286 721 4.16 / 435.62 2 3
Average= 4.15
(KJ/cycle)

Cycle 103 GMT 26/ 8/2022 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.22 485 221 0.22 / 427.38 2 2
2 7 2007.60 53 15.04 3174 2530 2.75 / 429.91 2 2
3 13 1014.56 18 15.06 1790 485 3.24 / 430.40 2 3
4 13 298.48 18 15.24 762 209 3.45 / 430.61 2 4
5 8 -0.28 165 15.28 285 719 4.16 / 431.33 2 3
6 14 -0.28 30 15.26 285 130 4.29 / 431.46 2 3
Average= 4.15
(KJ/cycle)

Cycle 102 GMT 16/ 8/2022 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 30 15.22 475 217 0.22 / 423.18 2 2
2 7 2006.12 53 15.05 3151 2513 2.73 / 425.70 2 2
3 13 1027.92 18 15.05 1805 489 3.22 / 426.19 2 3
4 13 443.88 18 15.21 972 266 3.49 / 426.45 2 4
5 8 0.28 165 15.29 282 711 4.20 / 427.16 2 3
Average= 4.15
(KJ/cycle)

Cycle 101 GMT 6/ 8/2022 5:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 30 15.20 480 219 0.22 / 419.12 2 2
2 7 2006.28 52 15.04 3165 2475 2.69 / 421.59 2 2
3 13 897.64 18 15.10 1624 441 3.14 / 422.03 2 4
4 13 337.40 18 15.24 815 224 3.36 / 422.26 2 4
5 8 0.04 165 15.29 281 709 4.07 / 422.97 2 4
Average= 4.15
(KJ/cycle)

Cycle 100 GMT 27/ 7/2022 7:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 15.21 467 213 0.21 / 414.86 2 2
2 7 2008.24 53 15.01 3153 2508 2.72 / 417.36 2 2
3 13 909.40 18 15.08 1643 446 3.17 / 417.81 2 4
4 13 479.12 18 15.19 1023 280 3.45 / 418.09 2 4
5 13 32.00 18 15.31 347 96 3.54 / 418.19 2 3
6 8 -0.04 165 15.27 283 713 4.26 / 418.90 2 3
Average= 4.15
(KJ/cycle)

Cycle 99 GMT 17/ 7/2022 10:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 30 15.23 482 220 0.22 / 410.66 2 2
2 7 2003.32 53 15.02 3163 2518 2.74 / 413.17 2 2
3 13 1019.28 18 15.04 1786 484 3.22 / 413.66 2 4
4 13 433.08 18 15.20 955 261 3.48 / 413.92 2 4
5 8 0.00 165 15.28 287 724 4.21 / 414.64 2 3
Average= 4.15
(KJ/cycle)

Cycle 98 GMT 7/ 7/2022 12:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 30 15.21 472 215 0.22 / 406.52 2 2
2 7 2006.56 53 15.04 3149 2510 2.73 / 409.03 2 2
3 13 1011.76 18 15.06 1780 483 3.21 / 409.51 2 3
4 13 291.40 18 15.26 747 205 3.41 / 409.72 2 3
5 8 0.12 165 15.29 284 716 4.13 / 410.44 2 3
Average= 4.15
(KJ/cycle)

Cycle 97 GMT 27/ 6/2022 14:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 30 15.21 460 210 0.21 / 402.10 2 2
2 7 2006.16 53 15.04 3154 2514 2.72 / 404.61 2 2
3 13 1011.88 18 15.08 1786 485 3.21 / 405.10 2 4
4 13 425.04 18 15.23 946 259 3.47 / 405.35 2 3
5 13 51.40 18 15.33 379 105 3.57 / 405.46 2 3
6 8 0.12 165 15.29 284 716 4.29 / 406.18 2 7
7 14 0.12 30 15.26 285 130 4.42 / 406.31 2 4
Average= 4.15
(KJ/cycle)

Cycle 96 GMT 17/ 6/2022 17:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 29 15.22 481 212 0.21 / 397.87 2 2
2 7 2002.32 52 15.05 3156 2470 2.68 / 400.34 2 2
3 13 1005.32 18 15.07 1775 481 3.16 / 400.82 2 4
4 13 415.08 18 15.23 923 253 3.42 / 401.07 2 4
5 13 22.88 18 15.33 334 92 3.51 / 401.16 2 2
6 8 0.04 165 15.30 286 722 4.23 / 401.89 2 2
Average= 4.14
(KJ/cycle)

Cycle 95 GMT 7/ 6/2022 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 30 15.23 454 207 0.21 / 393.58 2 2
2 7 2005.12 53 15.04 3160 2519 2.73 / 396.10 2 2
3 13 1014.72 18 15.08 1793 487 3.21 / 396.58 2 3
4 13 419.44 18 15.22 935 256 3.47 / 396.84 2 4
5 13 49.36 18 15.31 377 104 3.57 / 396.94 2 3
6 8 0.04 165 15.28 283 713 4.29 / 397.66 2 3
Average= 4.14
(KJ/cycle)

Cycle 94 GMT 28/ 5/2022 22: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 15.22 475 217 0.22 / 389.46 2 2
2 7 2003.08 53 15.03 3144 2504 2.72 / 391.96 2 2
3 13 1016.08 18 15.07 1794 487 3.21 / 392.45 2 4
4 13 301.88 18 15.26 766 210 3.42 / 392.66 2 3
5 8 0.00 165 15.30 282 712 4.13 / 393.37 2 4
Average= 4.14
(KJ/cycle)

Cycle 93 GMT 19/ 5/2022 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 30 15.21 482 220 0.22 / 385.22 2 2
2 7 2005.68 53 15.06 3151 2515 2.74 / 387.74 2 2
3 13 1003.92 18 15.10 1775 482 3.22 / 388.22 2 3
4 13 300.84 18 15.26 764 210 3.43 / 388.43 2 3
5 13 35.08 18 15.33 352 97 3.52 / 388.53 2 3
6 8 0.16 165 15.29 282 711 4.24 / 389.24 2 3
Average= 4.14
(KJ/cycle)

Cycle 92 GMT 9/ 5/2022 2:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 30 15.23 473 216 0.22 / 380.84 2 2
2 7 2010.56 53 15.02 3161 2516 2.73 / 383.36 2 2
3 13 1037.44 18 15.05 1819 493 3.23 / 383.85 2 4
4 13 314.20 18 15.25 779 214 3.44 / 384.06 2 3
5 13 39.08 18 15.32 359 99 3.54 / 384.16 2 3
6 8 -0.04 165 15.28 282 711 4.25 / 384.87 2 3
7 14 -0.04 30 15.25 282 129 4.38 / 385.00 2 3
Average= 4.14
(KJ/cycle)

Cycle 91 GMT 29/ 4/2022 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 30 15.24 468 214 0.21 / 376.47 2 2
2 7 2006.00 53 15.06 3151 2515 2.73 / 378.99 2 2
3 13 1020.96 18 15.07 1794 487 3.22 / 379.47 2 4
4 13 298.52 18 15.29 759 209 3.42 / 379.68 2 3
5 13 33.44 18 15.33 348 96 3.52 / 379.78 2 3
6 8 0.08 165 15.30 284 717 4.24 / 380.49 2 5
7 14 0.08 30 15.28 284 130 4.37 / 380.62 2 3
Average= 4.14
(KJ/cycle)

Cycle 90 GMT 19/ 4/2022 7:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 30 15.23 481 220 0.22 / 372.22 2 2
2 7 2004.00 53 15.07 3158 2522 2.74 / 374.75 2 2
3 13 1016.96 18 15.09 1795 488 3.23 / 375.23 2 3
4 13 304.04 18 15.29 765 211 3.44 / 375.44 2 3
5 13 32.36 18 15.35 348 96 3.54 / 375.54 2 3
6 8 0.08 165 15.31 284 717 4.25 / 376.26 2 3
Average= 4.13
(KJ/cycle)

Cycle 89 GMT 9/ 4/2022 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 30 15.24 474 217 0.22 / 368.02 2 2
2 7 2005.76 52 15.07 3155 2472 2.69 / 370.49 2 2
3 13 1019.88 18 15.09 1800 489 3.18 / 370.98 2 3
4 13 300.68 18 15.28 763 210 3.39 / 371.19 2 3
5 13 36.00 18 15.34 352 97 3.49 / 371.29 2 3
6 8 0.00 165 15.30 283 714 4.20 / 372.00 2 3
Average= 4.13
(KJ/cycle)

Cycle 88 GMT 30/ 3/2022 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.16 30 15.23 481 220 0.22 / 363.78 2 2
2 7 2003.12 53 15.06 3134 2501 2.72 / 366.29 2 2
3 13 1028.16 18 15.08 1806 490 3.21 / 366.78 2 3
4 13 315.36 18 15.28 784 216 3.43 / 366.99 2 3
5 13 39.16 18 15.34 359 99 3.53 / 367.09 2 3
6 8 -0.08 165 15.31 282 712 4.24 / 367.80 2 4
Average= 4.13
(KJ/cycle)

Cycle 87 GMT 20/ 3/2022 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 29 15.25 480 212 0.21 / 359.48 2 2
2 7 2004.16 53 15.07 3159 2523 2.74 / 362.00 2 2
3 13 1017.60 18 15.09 1792 487 3.22 / 362.49 2 4
4 13 415.20 18 15.25 930 255 3.48 / 362.74 2 4
5 13 46.52 18 15.35 373 103 3.58 / 362.85 2 3
6 8 0.00 165 15.32 284 718 4.30 / 363.57 2 3
Average= 4.13
(KJ/cycle)

Cycle 86 GMT 10/ 3/2022 16:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 29 15.26 474 210 0.21 / 355.29 2 2
2 7 2005.24 52 15.08 3142 2464 2.67 / 357.75 2 2
3 13 1017.08 18 15.10 1793 487 3.16 / 358.24 2 4
4 13 312.08 18 15.29 781 215 3.38 / 358.45 2 3
5 13 40.72 18 15.36 360 100 3.48 / 358.55 2 3
6 8 0.20 165 15.32 282 713 4.19 / 359.27 2 3
Average= 4.13
(KJ/cycle)

Cycle 85 GMT 28/ 2/2022 18:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 29 15.25 467 207 0.21 / 350.90 2 2
2 7 2007.64 53 15.07 3165 2528 2.73 / 353.43 2 2
3 13 1022.60 18 15.09 1795 488 3.22 / 353.92 2 3
4 13 303.12 18 15.29 769 212 3.43 / 354.13 2 3
5 13 38.28 18 15.36 359 99 3.53 / 354.23 2 3
6 8 0.12 165 15.32 285 720 4.25 / 354.95 2 4
7 14 0.12 30 15.29 285 131 4.38 / 355.08 2 3
Average= 4.13
(KJ/cycle)

Cycle 84 GMT 18/ 2/2022 20:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 29 15.25 486 215 0.21 / 346.48 2 2
2 7 2003.48 53 15.07 3152 2518 2.73 / 349.00 2 2
3 13 1011.44 18 15.11 1788 486 3.22 / 349.49 2 4
4 13 421.60 18 15.26 940 258 3.48 / 349.75 2 3
5 13 49.64 18 15.36 381 105 3.58 / 349.85 2 3
6 8 -0.16 165 15.31 283 715 4.30 / 350.57 2 3
7 14 -0.16 30 15.29 280 128 4.43 / 350.69 3 4
Average= 4.13
(KJ/cycle)

Cycle 83 GMT 8/ 2/2022 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 29 15.27 479 212 0.21 / 342.23 2 2
2 7 2004.12 52 15.07 3160 2476 2.69 / 344.71 2 2
3 13 1015.68 18 15.10 1797 488 3.18 / 345.20 2 3
4 13 424.56 18 15.25 945 259 3.44 / 345.46 2 4
5 13 29.56 18 15.36 344 95 3.53 / 345.55 2 3
6 8 -0.04 165 15.32 283 715 4.25 / 346.27 2 3
Average= 4.12
(KJ/cycle)

Cycle 82 GMT 30/ 1/2022 1:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 29 15.27 474 210 0.21 / 338.03 2 3
2 7 2007.44 52 15.06 3160 2475 2.68 / 340.51 2 2
3 13 1032.64 18 15.09 1812 492 3.18 / 341.00 2 4
4 13 322.12 18 15.29 798 220 3.40 / 341.22 2 3
5 13 19.72 18 15.37 326 90 3.49 / 341.31 2 3
6 8 -0.16 165 15.33 282 713 4.20 / 342.02 2 4
Average= 4.12
(KJ/cycle)

Cycle 81 GMT 20/ 1/2022 4: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 29 15.28 473 210 0.21 / 333.78 2 2
2 7 2008.40 53 15.07 3164 2527 2.74 / 336.31 2 2
3 13 1017.04 18 15.10 1795 488 3.22 / 336.80 2 4
4 13 305.56 18 15.31 773 213 3.44 / 337.01 2 4
5 13 18.92 18 15.38 330 91 3.53 / 337.10 2 2
6 8 0.04 165 15.35 285 722 4.25 / 337.82 2 3
Average= 4.12
(KJ/cycle)

Cycle 80 GMT 10/ 1/2022 6:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 29 15.28 474 210 0.21 / 329.49 2 2
2 7 2007.60 53 15.08 3165 2530 2.74 / 332.02 2 2
3 13 1011.00 18 15.12 1786 486 3.23 / 332.50 2 4
4 13 416.96 18 15.27 934 257 3.48 / 332.76 2 4
5 13 25.76 18 15.38 339 94 3.58 / 332.85 2 3
6 8 0.08 165 15.34 284 719 4.30 / 333.57 2 3
Average= 4.12
(KJ/cycle)

Cycle 79 GMT 31/12/2021 8:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 29 15.30 483 214 0.21 / 325.21 2 2
2 7 2004.32 53 15.09 3153 2522 2.74 / 327.73 2 2
3 13 1001.84 18 15.12 1762 480 3.22 / 328.21 2 3
4 13 410.92 18 15.28 923 254 3.47 / 328.47 2 4
5 13 24.64 18 15.38 333 92 3.56 / 328.56 2 3
6 8 0.04 165 15.35 283 717 4.28 / 329.28 2 4
Average= 4.12
(KJ/cycle)

Cycle 78 GMT 21/12/2021 11: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 15.30 462 205 0.20 / 320.93 2 2
2 7 2002.52 53 15.07 3146 2513 2.72 / 323.44 2 2
3 13 1011.12 18 15.12 1790 487 3.20 / 323.93 2 3
4 13 419.96 18 15.28 940 259 3.46 / 324.19 2 4
5 13 23.40 18 15.38 331 92 3.56 / 324.28 2 2
6 8 0.00 165 15.35 283 717 4.27 / 325.00 2 3
Average= 4.11
(KJ/cycle)

Cycle 77 GMT 11/12/2021 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 29 15.30 484 215 0.21 / 316.78 2 2
2 7 2004.32 53 15.08 3166 2530 2.75 / 319.31 2 2
3 13 1009.24 18 15.14 1785 486 3.23 / 319.80 2 3
4 13 276.84 18 15.35 730 202 3.43 / 320.00 2 4
5 8 0.20 165 15.37 287 728 4.16 / 320.73 2 3
Average= 4.11
(KJ/cycle)

Cycle 76 GMT 1/12/2021 15:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 29 15.32 481 214 0.21 / 312.51 2 2
2 7 2002.04 53 15.09 3146 2516 2.73 / 315.03 2 2
3 13 1001.40 18 15.15 1768 482 3.21 / 315.51 2 3
4 13 399.68 18 15.30 906 250 3.46 / 315.76 2 3
5 13 19.60 18 15.40 323 90 3.55 / 315.85 2 3
6 8 0.32 165 15.37 283 718 4.27 / 316.57 2 4
Average= 4.11
(KJ/cycle)

Cycle 75 GMT 21/11/2021 18:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 29 15.31 490 218 0.22 / 308.41 2 2
2 7 2008.20 52 15.09 3149 2471 2.69 / 310.88 2 3
3 13 1014.28 18 15.14 1789 488 3.18 / 311.37 2 3
4 13 295.44 18 15.33 755 208 3.38 / 311.58 2 4
5 8 0.00 165 15.38 282 716 4.10 / 312.30 2 2
Average= 4.11
(KJ/cycle)

Cycle 74 GMT 11/11/2021 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 29 15.31 490 218 0.22 / 304.19 2 2
2 7 2011.88 53 15.10 3156 2526 2.74 / 306.72 2 3
3 13 1019.84 18 15.14 1795 489 3.23 / 307.20 2 4
4 13 430.36 18 15.29 956 263 3.50 / 307.47 2 4
5 8 0.00 165 15.38 287 728 4.22 / 308.20 2 3
Average= 4.11
(KJ/cycle)

Cycle 73 GMT 1/11/2021 23: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 29 15.32 483 215 0.21 / 300.04 2 3
2 7 2002.84 53 15.07 3148 2514 2.73 / 302.55 2 2
3 13 1015.16 18 15.13 1788 487 3.22 / 303.04 2 4
4 13 298.92 18 15.34 757 209 3.42 / 303.25 2 3
5 8 0.16 165 15.37 285 723 4.15 / 303.97 2 3
Average= 4.11
(KJ/cycle)

Cycle 72 GMT 23/10/2021 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 29 15.32 486 216 0.22 / 295.76 2 3
2 7 2002.28 52 15.10 3143 2468 2.68 / 298.22 2 2
3 13 1008.08 18 15.14 1778 485 3.17 / 298.71 2 5
4 13 419.56 18 15.31 937 258 3.43 / 298.97 2 4
5 8 0.12 165 15.38 286 726 4.15 / 299.69 2 2
6 14 0.12 30 15.36 288 133 4.29 / 299.82 2 4
Average= 4.11
(KJ/cycle)

Cycle 71 GMT 13/10/2021 3:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 29 15.33 490 218 0.22 / 291.55 2 2
2 7 2006.68 53 15.09 3161 2528 2.75 / 294.07 2 2
3 13 1014.32 18 15.14 1785 486 3.23 / 294.56 2 4
4 13 414.88 18 15.31 932 257 3.49 / 294.82 2 4
5 8 0.08 165 15.38 285 723 4.21 / 295.54 2 3
Average= 4.10
(KJ/cycle)

Cycle 70 GMT 3/10/2021 6: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 29 15.33 488 217 0.22 / 287.40 2 2
2 7 2003.44 53 15.09 3148 2518 2.73 / 289.92 2 3
3 13 996.20 18 15.16 1767 482 3.22 / 290.40 2 5
4 13 279.32 18 15.35 730 202 3.42 / 290.60 2 3
5 8 0.04 165 15.39 286 726 4.14 / 291.33 2 3
Average= 4.10
(KJ/cycle)

Cycle 69 GMT 23/ 9/2021 8:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 29 15.34 489 218 0.22 / 283.26 2 3
2 7 2002.16 53 15.09 3147 2517 2.73 / 285.77 2 2
3 13 990.48 18 15.17 1757 480 3.21 / 286.25 2 4
4 13 273.40 18 15.37 728 201 3.42 / 286.46 2 4
5 8 0.32 165 15.41 286 727 4.14 / 287.18 2 3
Average= 4.10
(KJ/cycle)

Cycle 68 GMT 13/ 9/2021 10:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 15.34 466 207 0.21 / 279.11 2 3
2 7 2004.60 53 15.10 3156 2526 2.73 / 281.64 2 3
3 13 906.52 18 15.19 1641 449 3.18 / 282.08 2 4
4 13 334.64 18 15.33 818 226 3.41 / 282.31 2 3
5 8 -0.12 165 15.40 287 729 4.14 / 283.04 2 3
Average= 4.10
(KJ/cycle)

Cycle 67 GMT 3/ 9/2021 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 29 15.34 466 207 0.21 / 275.00 2 2
2 7 2005.40 52 15.11 3161 2484 2.69 / 277.49 2 2
3 13 1006.68 18 15.17 1783 487 3.18 / 277.97 2 4
4 13 277.76 18 15.38 735 203 3.38 / 278.18 2 3
5 8 0.12 165 15.42 285 725 4.11 / 278.90 2 2
Average= 4.10
(KJ/cycle)

Cycle 66 GMT 24/ 8/2021 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 29 15.33 480 213 0.21 / 270.82 2 2
2 7 2004.08 53 15.10 3136 2510 2.72 / 273.33 2 2
3 13 1009.44 18 15.16 1776 485 3.21 / 273.82 2 3
4 13 410.72 18 15.33 925 255 3.46 / 274.07 2 3
5 8 0.12 165 15.41 285 725 4.19 / 274.80 2 3
Average= 4.10
(KJ/cycle)

Cycle 65 GMT 14/ 8/2021 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 29 15.32 487 216 0.22 / 266.51 2 2
2 7 2003.88 53 15.07 3138 2506 2.72 / 269.01 2 2
3 13 1002.88 18 15.16 1773 484 3.21 / 269.50 2 3
4 13 417.20 18 15.30 933 257 3.46 / 269.75 2 4
5 8 -0.08 165 15.39 285 724 4.19 / 270.48 2 2
6 14 -0.08 30 15.37 286 132 4.32 / 270.61 2 3
Average= 4.10
(KJ/cycle)

Cycle 64 GMT 4/ 8/2021 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 29 15.36 456 203 0.20 / 262.35 2 2
2 7 2007.44 53 15.10 3157 2527 2.73 / 264.88 2 2
3 13 1007.28 18 15.16 1776 485 3.21 / 265.36 2 4
4 13 284.36 18 15.37 737 204 3.42 / 265.57 2 4
5 8 0.28 165 15.40 284 722 4.14 / 266.29 2 3
Average= 4.10
(KJ/cycle)

Cycle 63 GMT 25/ 7/2021 22: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 29 15.33 489 217 0.22 / 257.96 2 2
2 7 2002.56 53 15.09 3133 2506 2.72 / 260.47 2 2
3 13 1004.44 18 15.14 1768 482 3.20 / 260.95 2 4
4 13 417.36 18 15.32 931 257 3.46 / 261.21 2 4
5 13 28.60 18 15.45 341 95 3.56 / 261.30 2 3
6 8 0.64 165 15.41 283 720 4.28 / 262.02 2 3
7 14 0.64 30 15.39 281 130 4.41 / 262.15 2 3
Average= 4.10
(KJ/cycle)

Cycle 62 GMT 16/ 7/2021 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 29 15.33 466 207 0.21 / 253.76 2 3
2 7 2006.44 53 15.09 3156 2524 2.73 / 256.29 2 2
3 13 1003.72 18 15.16 1769 483 3.21 / 256.77 2 4
4 13 414.04 18 15.33 927 256 3.47 / 257.02 2 3
5 8 -0.20 165 15.41 283 720 4.19 / 257.74 2 4
Average= 4.09
(KJ/cycle)

Cycle 61 GMT 6/ 7/2021 2:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 29 15.34 467 208 0.21 / 249.51 2 3
2 7 2006.56 53 15.10 3153 2523 2.73 / 252.04 2 3
3 13 1008.68 18 15.16 1782 486 3.22 / 252.52 2 4
4 13 282.96 18 15.36 741 205 3.42 / 252.73 2 3
5 13 61.56 18 15.43 395 110 3.53 / 252.84 2 3
6 8 0.04 165 15.40 282 717 4.25 / 253.55 2 3
Average= 4.09
(KJ/cycle)

Cycle 60 GMT 26/ 6/2021 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 29 15.35 465 207 0.21 / 245.35 2 2
2 7 2003.60 53 15.09 3162 2529 2.74 / 247.88 2 3
3 13 1004.48 18 15.16 1775 484 3.22 / 248.37 2 4
4 13 283.80 18 15.37 745 206 3.43 / 248.57 2 3
5 8 -0.04 165 15.41 288 732 4.16 / 249.31 2 3
Average= 4.09
(KJ/cycle)

Cycle 59 GMT 16/ 6/2021 7:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 29 15.36 461 205 0.21 / 241.26 2 2
2 7 2004.76 52 15.11 3147 2473 2.68 / 243.73 2 2
3 13 1017.24 18 15.17 1785 487 3.17 / 244.22 2 4
4 13 292.88 18 15.38 751 208 3.37 / 244.42 2 3
5 8 0.28 165 15.43 284 723 4.10 / 245.15 2 3
Average= 4.09
(KJ/cycle)

Cycle 58 GMT 6/ 6/2021 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 29 15.37 472 210 0.21 / 237.11 2 2
2 7 2010.96 53 15.10 3164 2532 2.74 / 239.64 2 2
3 13 1014.48 18 15.17 1787 488 3.23 / 240.13 2 4
4 13 278.68 18 15.37 732 203 3.43 / 240.33 2 3
5 8 0.28 165 15.43 284 723 4.16 / 241.05 2 3
Average= 4.09
(KJ/cycle)

Cycle 57 GMT 27/ 5/2021 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 29 15.36 475 212 0.21 / 232.82 2 2
2 7 2005.88 53 15.11 3158 2529 2.74 / 235.35 2 2
3 13 1006.40 18 15.17 1778 486 3.23 / 235.84 2 3
4 13 286.88 18 15.39 744 206 3.43 / 236.04 2 3
5 8 0.68 165 15.43 284 723 4.16 / 236.76 2 2
6 14 0.68 30 15.40 283 131 4.29 / 236.90 3 4
Average= 4.08
(KJ/cycle)

Cycle 56 GMT 17/ 5/2021 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 29 15.37 462 206 0.21 / 228.65 2 2
2 7 2003.88 53 15.11 3152 2524 2.73 / 231.17 2 2
3 13 981.56 18 15.18 1740 475 3.21 / 231.65 2 5
4 13 371.04 18 15.37 866 240 3.45 / 231.89 2 3
5 8 0.04 165 15.44 284 724 4.17 / 232.61 2 2
Average= 4.08
(KJ/cycle)

Cycle 55 GMT 7/ 5/2021 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 29 15.38 486 217 0.22 / 224.41 2 2
2 7 2008.68 52 15.10 3159 2480 2.70 / 226.89 2 3
3 13 1012.08 18 15.19 1778 486 3.18 / 227.38 2 3
4 13 412.44 18 15.35 926 256 3.44 / 227.63 2 4
5 13 23.60 18 15.47 329 92 3.53 / 227.72 2 2
6 8 0.00 165 15.43 282 718 4.25 / 228.44 2 3
Average= 4.08
(KJ/cycle)

Cycle 54 GMT 27/ 4/2021 19: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 29 15.36 475 212 0.21 / 220.27 2 2
2 7 2002.16 53 15.11 3147 2520 2.73 / 222.79 2 2
3 13 993.48 18 15.19 1757 480 3.21 / 223.27 2 3
4 13 269.96 18 15.40 717 199 3.41 / 223.47 2 3
5 8 0.28 165 15.44 284 724 4.13 / 224.19 2 3
Average= 4.08
(KJ/cycle)

Cycle 53 GMT 17/ 4/2021 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 29 15.38 475 212 0.21 / 216.04 2 2
2 7 2002.64 53 15.13 3149 2525 2.74 / 218.57 2 2
3 13 988.76 18 15.19 1750 478 3.22 / 219.05 2 4
4 13 273.00 18 15.40 726 201 3.42 / 219.25 2 3
5 13 25.96 18 15.47 337 94 3.51 / 219.34 2 3
6 8 0.00 165 15.43 281 715 4.23 / 220.06 2 3
Average= 4.08
(KJ/cycle)

Cycle 52 GMT 7/ 4/2021 23:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 29 15.36 457 204 0.20 / 211.82 2 2
2 7 2003.68 53 15.11 3148 2521 2.72 / 214.34 2 2
3 13 996.92 18 15.19 1766 483 3.21 / 214.82 2 4
4 13 260.28 18 15.41 703 195 3.40 / 215.02 2 3
5 13 21.92 18 15.47 328 91 3.49 / 215.11 2 3
6 8 -0.12 165 15.43 283 721 4.21 / 215.83 2 2
Average= 4.07
(KJ/cycle)

Cycle 51 GMT 29/ 3/2021 2: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 29 15.37 455 203 0.20 / 207.66 2 2
2 7 2004.00 52 15.11 3144 2470 2.67 / 210.13 2 3
3 13 1000.52 18 15.19 1766 483 3.16 / 210.61 2 4
4 13 264.40 18 15.42 713 198 3.35 / 210.81 2 3
5 13 22.64 18 15.48 332 93 3.45 / 210.90 2 2
6 8 -0.08 165 15.44 282 718 4.16 / 211.62 2 3
Average= 4.07
(KJ/cycle)

Cycle 50 GMT 19/ 3/2021 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 29 15.37 479 214 0.21 / 203.44 2 2
2 7 2008.56 53 15.11 3146 2519 2.73 / 205.96 2 2
3 13 1002.20 18 15.20 1769 484 3.22 / 206.44 2 3
4 13 278.92 18 15.41 728 202 3.42 / 206.64 2 3
5 13 29.04 18 15.47 340 95 3.51 / 206.74 2 2
6 8 0.12 165 15.43 281 715 4.23 / 207.45 2 4
Average= 4.07
(KJ/cycle)

Cycle 49 GMT 9/ 3/2021 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 29 15.39 481 215 0.21 / 199.19 2 3
2 7 2006.84 53 15.12 3159 2531 2.75 / 201.72 2 3
3 13 999.68 18 15.20 1761 482 3.23 / 202.20 2 3
4 13 278.40 18 15.41 732 203 3.43 / 202.40 2 4
5 13 28.72 18 15.48 342 95 3.53 / 202.50 2 3
6 8 0.12 165 15.45 284 724 4.25 / 203.22 2 4
Average= 4.06
(KJ/cycle)

Cycle 48 GMT 27/ 2/2021 8:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 29 15.39 473 211 0.21 / 194.95 2 2
2 7 2005.84 53 15.13 3155 2530 2.74 / 197.48 2 2
3 13 993.72 18 15.21 1762 482 3.22 / 197.96 2 3
4 13 260.44 18 15.42 706 196 3.42 / 198.15 2 3
5 13 27.80 18 15.48 339 94 3.51 / 198.25 2 3
6 8 0.16 165 15.45 284 724 4.24 / 198.97 2 3
Average= 4.06
(KJ/cycle)

Cycle 47 GMT 17/ 2/2021 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 29 15.40 477 213 0.21 / 190.65 2 2
2 7 2004.08 53 15.13 3157 2532 2.74 / 193.19 2 2
3 13 1011.32 18 15.22 1781 488 3.23 / 193.67 2 3
4 13 404.80 18 15.38 918 254 3.49 / 193.93 2 4
5 13 22.52 18 15.49 329 92 3.58 / 194.02 2 2
6 8 0.12 165 15.45 281 716 4.29 / 194.74 2 3
Average= 4.06
(KJ/cycle)

Cycle 46 GMT 7/ 2/2021 13:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 28 15.41 476 205 0.21 / 186.42 2 3
2 7 2004.00 53 15.15 3148 2528 2.73 / 188.94 2 2
3 13 998.28 18 15.22 1769 485 3.22 / 189.43 2 4
4 13 261.08 18 15.44 706 196 3.41 / 189.62 2 3
5 13 25.76 18 15.49 337 94 3.51 / 189.72 2 3
6 8 0.08 165 15.46 283 722 4.23 / 190.44 2 3
Average= 4.05
(KJ/cycle)

Cycle 45 GMT 28/ 1/2021 15:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 28 15.39 487 210 0.21 / 182.18 2 3
2 7 2003.08 53 15.15 3157 2535 2.74 / 184.72 2 3
3 13 1004.12 18 15.23 1770 485 3.23 / 185.20 2 3
4 13 264.12 18 15.44 710 197 3.43 / 185.40 2 3
5 13 24.44 18 15.50 333 93 3.52 / 185.49 2 2
6 8 -0.08 165 15.47 282 720 4.24 / 186.21 2 3
Average= 4.05
(KJ/cycle)

Cycle 44 GMT 18/ 1/2021 18: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 28 15.41 481 208 0.21 / 177.93 2 3
2 7 2003.84 53 15.13 3154 2529 2.74 / 180.46 2 3
3 13 1003.36 18 15.23 1778 487 3.22 / 180.95 2 4
4 13 272.04 18 15.44 723 201 3.43 / 181.15 2 3
5 13 24.80 18 15.49 336 94 3.52 / 181.24 2 2
6 8 0.00 165 15.46 286 730 4.25 / 181.97 2 3
Average= 4.04
(KJ/cycle)

Cycle 43 GMT 8/ 1/2021 20:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 28 15.42 476 206 0.21 / 173.67 2 3
2 7 2004.40 53 15.15 3165 2541 2.75 / 176.22 2 2
3 13 998.72 18 15.23 1767 484 3.23 / 176.70 2 3
4 13 271.92 18 15.44 726 202 3.43 / 176.90 2 3
5 13 22.64 18 15.51 330 92 3.53 / 176.99 2 3
6 8 0.04 165 15.48 285 728 4.25 / 177.72 2 3
Average= 4.04
(KJ/cycle)

Cycle 42 GMT 29/12/2020 22:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 28 15.42 485 209 0.21 / 169.53 2 2
2 7 2002.68 53 15.14 3153 2530 2.74 / 172.06 2 3
3 13 995.48 18 15.24 1761 483 3.22 / 172.54 2 3
4 13 270.92 18 15.44 724 201 3.42 / 172.75 2 3
5 8 0.16 165 15.49 283 723 4.15 / 173.47 2 2
Average= 4.03
(KJ/cycle)

Cycle 41 GMT 20/12/2020 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 28 15.41 488 211 0.21 / 165.45 2 2
2 7 2002.44 52 15.16 3150 2483 2.69 / 167.94 2 3
3 13 881.96 18 15.28 1608 442 3.14 / 168.38 2 4
4 13 304.80 18 15.45 770 214 3.35 / 168.59 2 3
5 8 0.20 165 15.49 285 728 4.08 / 169.32 2 3
Average= 4.03
(KJ/cycle)

Cycle 40 GMT 10/12/2020 3:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 28 15.43 486 210 0.21 / 161.35 2 2
2 7 2004.04 52 15.13 3147 2476 2.69 / 163.82 2 3
3 13 1001.92 18 15.23 1774 486 3.17 / 164.31 2 4
4 13 273.12 18 15.44 728 202 3.37 / 164.51 2 3
5 8 0.04 165 15.47 286 730 4.10 / 165.24 2 2
Average= 4.03
(KJ/cycle)

Cycle 39 GMT 30/11/2020 5:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 28 15.44 480 208 0.21 / 157.20 2 2
2 7 2005.04 53 15.16 3154 2534 2.74 / 159.74 2 3
3 13 982.04 18 15.26 1750 481 3.22 / 160.22 2 4
4 13 247.84 18 15.47 688 192 3.41 / 160.41 2 3
5 8 -0.16 165 15.50 286 731 4.15 / 161.14 2 2
Average= 4.03
(KJ/cycle)

Cycle 38 GMT 20/11/2020 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 28 15.42 485 209 0.21 / 153.05 2 2
2 7 2002.76 53 15.16 3148 2529 2.74 / 155.58 2 2
3 13 993.80 18 15.25 1760 483 3.22 / 156.06 2 5
4 13 267.76 18 15.46 723 201 3.42 / 156.26 2 3
5 8 0.16 165 15.50 287 734 4.16 / 156.99 2 3
Average= 4.03
(KJ/cycle)

Cycle 37 GMT 10/11/2020 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 28 15.44 462 200 0.20 / 148.74 2 3
2 7 2003.72 53 15.15 3158 2536 2.74 / 151.28 2 3
3 13 1011.52 18 15.24 1791 491 3.23 / 151.77 2 5
4 13 269.00 18 15.46 721 201 3.43 / 151.97 2 3
5 8 0.16 165 15.49 287 734 4.16 / 152.70 2 5
6 14 0.16 30 15.48 286 133 4.29 / 152.84 2 3
Average= 4.02
(KJ/cycle)

Cycle 36 GMT 31/10/2020 12:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 28 15.43 489 211 0.21 / 144.45 2 2
2 7 2004.12 53 15.17 3148 2531 2.74 / 146.98 2 3
3 13 1009.80 18 15.25 1783 489 3.23 / 147.47 2 4
4 13 267.92 18 15.46 721 201 3.43 / 147.67 2 3
5 8 0.28 165 15.50 287 734 4.17 / 148.41 2 2
6 14 0.28 30 15.49 288 134 4.30 / 148.54 2 2
Average= 4.01
(KJ/cycle)

Cycle 35 GMT 21/10/2020 14:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 28 15.45 485 210 0.21 / 140.28 2 3
2 7 2007.60 53 15.15 3169 2545 2.75 / 142.82 2 3
3 13 1007.56 18 15.24 1778 488 3.24 / 143.31 2 3
4 13 254.92 18 15.46 701 195 3.44 / 143.51 2 3
5 8 -0.04 165 15.49 288 736 4.17 / 144.24 2 3
Average= 4.01
(KJ/cycle)

Cycle 34 GMT 11/10/2020 17: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 28 15.45 495 214 0.21 / 136.20 2 2
2 7 2004.00 53 15.16 3158 2537 2.75 / 138.73 2 3
3 13 880.04 18 15.31 1600 441 3.19 / 139.17 2 4
4 13 186.36 18 15.49 597 166 3.36 / 139.34 2 3
5 8 -0.16 165 15.50 285 729 4.09 / 140.07 2 3
Average= 4.00
(KJ/cycle)

Cycle 33 GMT 1/10/2020 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 28 15.45 491 212 0.21 / 131.98 2 2
2 7 2002.44 53 15.18 3158 2541 2.75 / 134.53 2 2
3 13 982.16 18 15.29 1750 482 3.23 / 135.01 2 5
4 13 370.24 18 15.44 872 242 3.48 / 135.25 2 4
5 8 0.04 165 15.52 286 732 4.21 / 135.98 2 3
Average= 4.00
(KJ/cycle)

Cycle 32 GMT 21/ 9/2020 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 28 15.45 485 210 0.21 / 127.84 2 2
2 7 2004.80 53 15.17 3145 2529 2.74 / 130.37 2 2
3 13 992.64 18 15.27 1750 481 3.22 / 130.85 2 3
4 13 248.56 18 15.48 685 191 3.41 / 131.04 2 3
5 8 0.24 165 15.51 285 729 4.14 / 131.77 2 2
Average= 3.99
(KJ/cycle)

Cycle 31 GMT 11/ 9/2020 23:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 15.45 473 205 0.20 / 123.70 2 2
2 7 2002.60 53 15.18 3152 2536 2.74 / 126.24 2 2
3 13 974.28 18 15.28 1732 476 3.22 / 126.72 2 3
4 13 233.80 18 15.49 666 186 3.40 / 126.90 2 3
5 8 -0.04 165 15.52 285 730 4.13 / 127.63 2 3
Average= 3.99
(KJ/cycle)

Cycle 30 GMT 2/ 9/2020 2:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 28 15.45 487 211 0.21 / 119.55 2 2
2 7 2006.20 53 15.17 3153 2535 2.75 / 122.09 2 2
3 13 990.68 18 15.28 1759 484 3.23 / 122.57 2 3
4 13 259.44 18 15.48 708 197 3.43 / 122.77 2 3
5 8 0.04 165 15.52 286 732 4.16 / 123.50 2 3
Average= 3.98
(KJ/cycle)

Cycle 29 GMT 23/ 8/2020 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 28 15.44 480 208 0.21 / 115.45 2 2
2 7 2004.48 53 15.16 3144 2526 2.73 / 117.97 2 2
3 13 868.92 18 15.30 1578 435 3.17 / 118.41 2 3
4 13 288.12 18 15.47 744 207 3.38 / 118.61 2 3
5 8 -0.24 165 15.52 284 727 4.10 / 119.34 2 2
Average= 3.98
(KJ/cycle)

Cycle 28 GMT 13/ 8/2020 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 28 15.46 495 214 0.21 / 111.34 2 2
2 7 2007.36 53 15.16 3146 2528 2.74 / 113.86 2 2
3 13 1002.00 18 15.27 1770 487 3.23 / 114.35 2 3
4 13 160.08 18 15.50 557 155 3.38 / 114.51 2 3
5 8 0.28 165 15.50 286 731 4.12 / 115.24 2 3
Average= 3.97
(KJ/cycle)

Cycle 27 GMT 3/ 8/2020 9: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 28 15.44 479 207 0.21 / 107.24 2 2
2 7 2003.44 52 15.17 3136 2474 2.68 / 109.71 2 2
3 13 995.32 18 15.28 1763 485 3.17 / 110.20 2 3
4 13 251.60 18 15.49 689 192 3.36 / 110.39 2 3
5 8 -0.04 165 15.53 286 733 4.09 / 111.12 2 2
Average= 3.97
(KJ/cycle)

Cycle 26 GMT 24/ 7/2020 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 28 15.44 491 212 0.21 / 103.09 2 2
2 7 2004.08 53 15.18 3142 2528 2.74 / 105.62 2 2
3 13 998.36 18 15.26 1764 485 3.22 / 106.11 2 3
4 13 260.08 18 15.48 705 196 3.42 / 106.30 2 3
5 8 0.16 165 15.51 285 729 4.15 / 107.03 2 3
Average= 3.96
(KJ/cycle)

Cycle 25 GMT 14/ 7/2020 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 28 15.46 480 208 0.21 / 98.95 2 2
2 7 2002.56 53 15.18 3149 2533 2.74 / 101.49 2 2
3 13 980.56 18 15.26 1733 476 3.22 / 101.96 2 3
4 13 240.40 18 15.47 676 188 3.41 / 102.15 2 3
5 8 0.16 165 15.50 286 731 4.14 / 102.88 2 3
Average= 3.96
(KJ/cycle)

Cycle 24 GMT 4/ 7/2020 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 28 15.47 456 198 0.20 / 94.89 2 2
2 7 2007.08 53 15.17 3153 2535 2.73 / 97.43 2 2
3 13 861.68 18 15.31 1569 432 3.16 / 97.86 2 3
4 13 164.12 18 15.51 563 157 3.32 / 98.02 2 3
5 8 0.08 165 15.52 284 727 4.05 / 98.74 2 3
Average= 3.95
(KJ/cycle)

Cycle 23 GMT 24/ 6/2020 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 28 15.46 486 210 0.21 / 90.82 2 2
2 7 2007.68 53 15.19 3162 2546 2.76 / 93.36 2 2
3 13 872.04 18 15.33 1582 437 3.19 / 93.80 2 3
4 13 183.56 18 15.51 594 166 3.36 / 93.97 2 3
5 8 0.00 165 15.52 285 730 4.09 / 94.70 2 3
Average= 3.95
(KJ/cycle)

Cycle 22 GMT 14/ 6/2020 20:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 28 15.47 459 199 0.20 / 86.67 2 2
2 7 2005.56 53 15.18 3138 2525 2.72 / 89.20 2 2
3 13 990.76 18 15.29 1754 483 3.21 / 89.68 2 3
4 13 257.44 18 15.50 702 196 3.40 / 89.87 2 3
5 8 -0.08 165 15.53 286 733 4.13 / 90.61 2 3
Average= 3.94
(KJ/cycle)

Cycle 21 GMT 4/ 6/2020 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 28 15.46 486 210 0.21 / 82.53 2 2
2 7 2006.92 53 15.21 3145 2535 2.75 / 85.07 2 2
3 13 985.40 18 15.31 1751 483 3.23 / 85.55 2 3
4 13 240.80 18 15.52 680 190 3.42 / 85.74 2 3
5 8 0.08 165 15.54 285 731 4.15 / 86.47 2 2
Average= 3.93
(KJ/cycle)

Cycle 20 GMT 26/ 5/2020 0:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 28 15.46 486 210 0.21 / 78.40 2 2
2 7 2006.60 53 15.20 3159 2545 2.76 / 80.95 2 2
3 13 867.16 18 15.32 1573 434 3.19 / 81.38 2 3
4 13 294.04 18 15.48 754 210 3.40 / 81.59 2 3
5 8 0.12 165 15.54 285 731 4.13 / 82.32 2 2
Average= 3.92
(KJ/cycle)

Cycle 19 GMT 16/ 5/2020 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 28 15.47 484 210 0.21 / 74.25 2 2
2 7 2004.68 53 15.22 3149 2540 2.75 / 76.79 2 2
3 13 987.24 18 15.30 1748 481 3.23 / 77.27 2 2
4 13 251.84 18 15.50 694 194 3.42 / 77.47 2 3
5 8 0.28 165 15.54 283 726 4.15 / 78.19 2 2
Average= 3.91
(KJ/cycle)

Cycle 18 GMT 6/ 5/2020 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 28 15.48 457 198 0.20 / 69.79 2 2
2 7 2007.56 53 15.22 3133 2527 2.73 / 72.32 2 2
3 13 982.52 18 15.32 1737 479 3.20 / 72.80 2 2
4 13 241.28 18 15.51 678 189 3.39 / 72.99 2 2
5 8 -0.16 165 15.54 284 728 4.12 / 73.71 2 2
6 14 -0.16 75 15.51 282 328 4.45 / 74.04 2 3
Average= 3.90
(KJ/cycle)

Cycle 17 GMT 26/ 4/2020 7:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 28 15.49 479 208 0.21 / 65.59 2 2
2 7 2006.40 53 15.22 3154 2544 2.75 / 68.14 2 2
3 13 980.12 18 15.31 1742 480 3.23 / 68.62 2 2
4 13 382.80 18 15.48 885 247 3.48 / 68.86 2 2
5 8 0.08 165 15.54 284 728 4.21 / 69.59 2 2
Average= 3.87
(KJ/cycle)

Cycle 16 GMT 16/ 4/2020 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 28 15.48 470 204 0.20 / 61.51 2 2
2 7 2008.04 53 15.21 3155 2543 2.75 / 64.05 2 2
3 13 885.68 18 15.33 1599 441 3.19 / 64.49 2 2
4 13 187.60 18 15.53 597 167 3.36 / 64.66 2 3
5 8 0.16 165 15.55 284 729 4.08 / 65.39 2 2
Average= 3.85
(KJ/cycle)

Cycle 15 GMT 6/ 4/2020 12: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 28 15.47 460 199 0.20 / 57.41 2 2
2 7 2004.00 52 15.22 3144 2488 2.69 / 59.90 2 2
3 13 1000.32 18 15.32 1763 486 3.17 / 60.38 2 2
4 13 255.44 18 15.51 698 195 3.37 / 60.58 2 3
5 8 -0.20 165 15.54 282 723 4.09 / 61.30 2 2
Average= 3.83
(KJ/cycle)

Cycle 14 GMT 27/ 3/2020 14: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 15.47 454 197 0.20 / 53.29 2 2
2 7 2006.80 53 15.22 3160 2549 2.75 / 55.84 2 2
3 13 872.08 18 15.35 1590 439 3.19 / 56.27 2 2
4 13 279.56 18 15.51 734 205 3.39 / 56.48 2 2
5 8 0.20 165 15.55 285 731 4.12 / 57.21 2 2
Average= 3.81
(KJ/cycle)

Cycle 13 GMT 17/ 3/2020 16:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 28 15.47 486 211 0.21 / 49.08 2 2
2 7 2002.12 53 15.21 3126 2520 2.73 / 51.60 2 2
3 13 983.48 18 15.31 1740 480 3.21 / 52.08 2 2
4 13 228.32 18 15.51 661 185 3.39 / 52.27 2 2
5 13 21.60 18 15.58 329 92 3.49 / 52.36 2 2
6 8 0.28 165 15.54 285 731 4.22 / 53.09 2 2
Average= 3.79
(KJ/cycle)

Cycle 12 GMT 7/ 3/2020 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 28 15.49 466 202 0.20 / 44.83 2 2
2 7 2005.52 52 15.21 3159 2499 2.70 / 47.33 2 2
3 13 978.48 18 15.31 1735 478 3.18 / 47.81 2 2
4 13 377.72 18 15.47 879 245 3.42 / 48.05 2 2
5 13 17.84 18 15.57 323 91 3.51 / 48.14 2 2
6 8 0.08 165 15.54 285 731 4.24 / 48.87 2 3
Average= 3.76
(KJ/cycle)

Cycle 11 GMT 26/ 2/2020 20:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 28 15.48 479 208 0.21 / 40.66 2 2
2 7 2002.48 52 15.24 3134 2484 2.69 / 43.14 2 2
3 13 977.52 18 15.34 1734 479 3.17 / 43.62 2 2
4 13 247.80 18 15.53 686 192 3.36 / 43.81 2 2
5 13 23.52 18 15.59 329 92 3.45 / 43.90 2 2
6 8 -0.04 165 15.55 282 724 4.18 / 44.63 2 3
Average= 3.72
(KJ/cycle)

Cycle 10 GMT 16/ 2/2020 22:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 28 15.50 475 206 0.21 / 36.45 2 2
2 7 2003.24 53 15.24 3147 2542 2.75 / 38.99 2 2
3 13 858.20 18 15.38 1565 433 3.18 / 39.43 2 2
4 13 278.72 18 15.52 731 204 3.39 / 39.63 2 2
5 13 23.52 18 15.59 330 93 3.48 / 39.72 2 2
6 8 0.04 165 15.54 283 726 4.20 / 40.45 2 2
Average= 3.68
(KJ/cycle)

Cycle 9 GMT 7/ 2/2020 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 27 15.50 476 199 0.20 / 32.23 2 2
2 7 2006.64 53 15.23 3136 2531 2.73 / 34.76 2 2
3 13 982.96 18 15.33 1736 479 3.21 / 35.24 2 2
4 13 245.84 18 15.54 680 190 3.40 / 35.43 2 2
5 13 21.40 18 15.60 327 92 3.49 / 35.52 2 2
6 8 0.04 165 15.56 281 721 4.21 / 36.25 2 2
Average= 3.62
(KJ/cycle)

Cycle 8 GMT 28/ 1/2020 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 27 15.50 477 200 0.20 / 28.02 2 2
2 7 2007.64 53 15.24 3149 2544 2.74 / 30.57 2 2
3 13 861.04 18 15.37 1573 435 3.18 / 31.00 2 2
4 13 280.28 18 15.53 737 206 3.38 / 31.21 2 3
5 13 25.68 18 15.59 335 94 3.48 / 31.30 2 2
6 8 -0.04 165 15.56 284 729 4.21 / 32.03 2 3
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 18/ 1/2020 5:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 27 15.50 470 197 0.20 / 23.88 2 2
2 7 2006.92 53 15.23 3148 2541 2.74 / 26.42 2 2
3 13 989.32 18 15.34 1749 483 3.22 / 26.91 2 2
4 13 241.48 18 15.54 675 189 3.41 / 27.10 2 3
5 8 -0.04 165 15.57 284 730 4.14 / 27.82 2 2
Average= 3.48
(KJ/cycle)

Cycle 6 GMT 8/ 1/2020 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 26 15.52 472 190 0.19 / 19.78 2 2
2 10 1013.12 2 15.45 1833 57 0.25 / 19.84 2 2
3 7 2002.96 53 15.24 3139 2535 2.78 / 22.37 2 2
4 13 865.60 18 15.37 1569 434 3.22 / 22.81 2 2
5 13 159.40 18 15.56 551 154 3.37 / 22.96 2 3
6 8 0.20 165 15.57 282 724 4.10 / 23.69 2 2
Average= 3.38
(KJ/cycle)

Cycle 5 GMT 29/12/2019 9:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 25 15.52 478 185 0.19 / 15.66 2 2
2 10 1027.08 2 15.46 1859 57 0.24 / 15.71 2 2
3 7 2003.88 53 15.24 3128 2527 2.77 / 18.24 2 2
4 13 843.28 18 15.40 1542 427 3.20 / 18.67 2 2
5 13 253.28 18 15.55 693 194 3.39 / 18.86 2 3
6 8 0.04 165 15.56 284 729 4.12 / 19.59 2 2
Average= 3.27
(KJ/cycle)

Cycle 4 GMT 19/12/2019 11:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 27 15.51 473 198 0.20 / 12.24 2 2
2 3 962.20 -1 15.86 3 0 0.00 / 12.24 2 2
3 7 1519.28 52 15.37 2473 1977 2.17 / 14.22 2 2
4 13 742.68 18 15.44 1397 388 2.56 / 14.60 2 2
5 13 133.40 18 15.57 508 142 2.71 / 14.75 2 3
6 8 0.00 165 15.57 282 724 3.43 / 15.47 2 3
Average= 3.09
(KJ/cycle)

Cycle 3 GMT 18/12/2019 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 26 15.51 470 190 0.19 / 8.44 2 2
2 7 1524.00 74 15.18 2453 2756 2.95 / 11.20 2 2
3 13 98.96 18 15.59 452 127 3.07 / 11.32 2 3
4 8 0.00 165 15.57 279 717 3.79 / 12.04 2 2
Average= 3.01
(KJ/cycle)

Cycle 2 GMT 17/12/2019 11:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 26 15.55 467 189 0.19 / 4.66 2 2
2 7 1521.60 74 15.19 2446 2749 2.94 / 7.41 2 2
3 13 95.24 18 15.60 446 125 3.06 / 7.54 2 2
4 8 0.20 165 15.59 278 715 3.78 / 8.25 2 2
Average= 2.75
(KJ/cycle)

Cycle 1 GMT 16/12/2019 12:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 23 15.72 424 153 0.15 / 1.68 2 3
2 10 1002.12 3 15.53 1800 84 0.24 / 1.76 2 2
3 3 1021.84 1 15.57 1847 29 0.27 / 1.79 2 2
4 7 1007.84 74 15.37 1727 1964 2.23 / 3.76 2 2
5 8 0.16 165 15.62 278 716 2.95 / 4.47 2 3
Average= 2.24
(KJ/cycle)

Cycle 0 GMT 16/12/2019 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 73.32 22 15.84 381 133 0.13 / 0.13 2 3
2 7 86.80 74 15.81 392 459 0.59 / 0.59 2 2
3 8 0.16 240 15.78 247 935 1.53 / 1.53 2 7
Average= 1.53
(KJ/cycle)