SIO Argo Site:
Pump Diagnostics Page   



Serial= 8720 WMO= 5905777

Return

←PreviousNext→

Cycle 226 GMT 19/12/2024 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 34 15.03 451 230 0.23 / 891.99 2 14
2 7 2007.24 32 14.86 2914 1386 1.62 / 893.38 2 22
3 13 1674.56 20 14.84 2528 750 2.37 / 894.13 5 35
4 13 1007.88 20 14.87 1712 509 2.88 / 894.64 15 245
5 13 479.04 20 14.99 784 235 3.11 / 894.87 245 245
6 13 58.00 20 15.07 265 80 3.19 / 894.95 245 245
7 13 37.80 20 15.07 240 72 3.26 / 895.03 245 245
8 13 17.36 20 15.07 228 69 3.33 / 895.10 245 245
9 8 -0.20 165 15.05 207 514 3.85 / 895.61 245 244
10 14 -0.20 1 15.04 213 3 3.85 / 895.61 244 244
Average= 3.95
(KJ/cycle)

Cycle 225 GMT 9/12/2024 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 34 15.02 456 233 0.23 / 888.13 2 14
2 7 2003.84 32 14.87 2904 1382 1.61 / 889.51 2 20
3 13 1675.32 20 14.84 2545 755 2.37 / 890.27 5 35
4 13 1142.52 20 14.85 1879 558 2.93 / 890.83 14 72
5 13 454.76 20 14.99 801 240 3.17 / 891.07 31 245
6 13 61.96 20 15.07 270 81 3.25 / 891.15 245 245
7 13 17.44 20 15.07 238 72 3.32 / 891.22 245 245
8 8 -0.08 165 15.05 218 541 3.86 / 891.76 245 244
9 14 -0.08 1 15.05 218 3 3.87 / 891.76 244 244
Average= 3.95
(KJ/cycle)

Cycle 224 GMT 29/11/2024 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 34 15.03 463 237 0.24 / 884.25 2 14
2 7 2009.32 32 14.88 2901 1381 1.62 / 885.64 2 19
3 13 1683.96 20 14.84 2561 760 2.38 / 886.40 5 32
4 13 1156.08 20 14.85 1908 567 2.94 / 886.96 13 60
5 13 458.28 20 14.98 846 253 3.20 / 887.22 29 245
6 13 62.92 20 15.07 270 81 3.28 / 887.30 245 245
7 13 34.96 20 15.07 238 72 3.35 / 887.37 245 245
8 8 -0.04 165 15.05 213 529 3.88 / 887.90 245 244
Average= 3.95
(KJ/cycle)

Cycle 223 GMT 19/11/2024 18:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 34 15.05 436 223 0.22 / 880.40 2 14
2 7 2004.36 32 14.88 2897 1379 1.60 / 881.78 2 20
3 13 1680.36 20 14.85 2557 759 2.36 / 882.54 5 33
4 13 1030.40 20 14.87 1720 512 2.87 / 883.05 12 58
5 13 516.44 20 14.98 907 272 3.15 / 883.33 30 245
6 13 66.84 20 15.07 277 83 3.23 / 883.41 245 245
7 13 20.92 20 15.07 238 72 3.30 / 883.48 245 245
8 8 -0.20 165 15.05 215 534 3.83 / 884.01 245 245
9 14 -0.20 1 15.05 234 4 3.84 / 884.02 244 244
Average= 3.95
(KJ/cycle)

Cycle 222 GMT 9/11/2024 20:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 34 15.01 473 241 0.24 / 876.67 2 15
2 7 2007.16 32 14.88 2906 1384 1.63 / 878.05 2 19
3 13 1674.64 20 14.85 2521 749 2.37 / 878.80 5 34
4 13 1013.92 20 14.88 1715 510 2.88 / 879.31 13 61
5 13 484.08 20 14.99 829 249 3.13 / 879.56 30 245
6 13 37.84 20 15.08 267 81 3.21 / 879.64 245 245
7 8 -0.04 165 15.06 217 539 3.75 / 880.18 245 245
8 14 -0.04 1 15.06 219 3 3.76 / 880.18 245 245
Average= 3.95
(KJ/cycle)

Cycle 221 GMT 30/10/2024 22:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 34 15.01 459 234 0.23 / 872.95 2 14
2 7 2008.12 32 14.88 2902 1382 1.62 / 874.33 2 18
3 13 1539.36 20 14.86 2387 709 2.33 / 875.04 4 31
4 13 1052.12 20 14.87 1760 523 2.85 / 875.56 12 57
5 13 389.88 20 15.00 769 231 3.08 / 875.79 27 245
6 13 45.72 20 15.08 278 84 3.16 / 875.88 245 245
7 8 -0.12 165 15.06 220 547 3.71 / 876.42 245 245
Average= 3.95
(KJ/cycle)

Cycle 220 GMT 21/10/2024 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 34 15.02 471 241 0.24 / 869.22 2 14
2 7 2006.60 32 14.88 2926 1393 1.63 / 870.61 2 20
3 13 1551.52 20 14.85 2398 712 2.35 / 871.33 4 29
4 13 1062.76 20 14.86 1801 535 2.88 / 871.86 11 52
5 13 391.04 20 14.99 799 240 3.12 / 872.10 26 245
6 13 46.36 20 15.07 279 84 3.20 / 872.18 245 245
7 8 -0.16 165 15.06 213 529 3.73 / 872.71 245 245
Average= 3.95
(KJ/cycle)

Cycle 219 GMT 11/10/2024 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 34 15.02 475 243 0.24 / 865.49 2 14
2 7 2006.48 33 14.87 2916 1431 1.67 / 866.92 2 18
3 13 1544.32 20 14.85 2375 705 2.38 / 867.63 4 30
4 13 1044.68 20 14.87 1752 521 2.90 / 868.15 11 52
5 13 353.16 20 15.01 732 220 3.12 / 868.37 26 245
6 13 18.48 20 15.08 253 76 3.20 / 868.45 245 245
7 8 -0.12 165 15.06 215 534 3.73 / 868.98 245 245
Average= 3.95
(KJ/cycle)

Cycle 218 GMT 1/10/2024 5:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 34 15.02 469 240 0.24 / 861.76 2 14
2 7 2006.28 32 14.87 2907 1383 1.62 / 863.14 2 20
3 13 1546.32 20 14.86 2381 708 2.33 / 863.85 4 28
4 13 1063.16 20 14.86 1798 534 2.86 / 864.39 10 51
5 13 399.28 20 14.99 825 247 3.11 / 864.63 24 245
6 13 22.84 20 15.08 279 84 3.20 / 864.72 245 245
7 8 -0.20 165 15.06 214 532 3.73 / 865.25 245 245
Average= 3.95
(KJ/cycle)

Cycle 217 GMT 21/ 9/2024 7:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 34 15.01 476 243 0.24 / 858.00 2 13
2 7 2011.60 32 14.87 2913 1386 1.63 / 859.39 2 19
3 13 1675.24 20 14.84 2540 754 2.38 / 860.14 4 27
4 13 1137.76 20 14.86 1896 563 2.95 / 860.71 10 49
5 13 420.96 20 14.99 861 258 3.20 / 860.96 23 245
6 8 0.20 165 15.07 224 557 3.76 / 861.52 245 245
Average= 3.95
(KJ/cycle)

Cycle 216 GMT 11/ 9/2024 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 34 15.02 455 232 0.23 / 854.28 2 13
2 7 2004.40 32 14.87 2907 1383 1.62 / 855.67 2 19
3 13 1536.20 20 14.86 2363 702 2.32 / 856.37 4 27
4 13 1037.52 20 14.87 1758 523 2.84 / 856.89 10 48
5 13 362.60 20 15.00 788 236 3.08 / 857.13 22 245
6 13 17.88 20 15.08 278 84 3.16 / 857.21 245 245
7 8 -0.20 165 15.06 220 547 3.71 / 857.76 245 245
Average= 3.95
(KJ/cycle)

Cycle 215 GMT 1/ 9/2024 11:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 34 15.03 451 230 0.23 / 850.47 2 13
2 7 2003.16 33 14.87 2894 1420 1.65 / 851.89 2 18
3 13 1676.96 20 14.85 2530 751 2.40 / 852.64 4 26
4 13 1010.32 20 14.88 1694 504 2.91 / 853.15 9 44
5 13 493.28 20 14.97 962 288 3.19 / 853.43 22 245
6 13 28.16 20 15.08 280 84 3.28 / 853.52 245 245
7 8 -0.08 165 15.06 215 534 3.81 / 854.05 245 245
Average= 3.95
(KJ/cycle)

Cycle 214 GMT 22/ 8/2024 14:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 34 15.02 459 234 0.23 / 846.75 2 12
2 7 2004.20 32 14.87 2905 1382 1.62 / 848.13 2 18
3 13 1675.56 20 14.85 2533 752 2.37 / 848.88 4 26
4 13 1132.72 20 14.87 1851 550 2.92 / 849.43 9 46
5 13 421.12 20 14.99 875 262 3.18 / 849.70 20 245
6 8 -0.20 165 15.07 219 545 3.73 / 850.24 245 245
Average= 3.95
(KJ/cycle)

Cycle 213 GMT 12/ 8/2024 16:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 34 15.03 458 234 0.23 / 842.99 2 12
2 7 2009.76 32 14.88 2899 1380 1.61 / 844.37 2 18
3 13 1687.64 20 14.84 2546 756 2.37 / 845.13 4 25
4 13 1021.32 20 14.88 1732 515 2.89 / 845.64 8 40
5 13 382.60 20 15.00 842 253 3.14 / 845.90 18 245
6 13 17.60 20 15.08 281 85 3.22 / 845.98 245 245
7 8 0.08 165 15.06 214 532 3.75 / 846.51 245 245
Average= 3.96
(KJ/cycle)

Cycle 212 GMT 2/ 8/2024 18:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 34 15.02 456 233 0.23 / 839.28 2 12
2 7 2003.04 33 14.87 2911 1428 1.66 / 840.71 2 17
3 13 1664.72 20 14.85 2542 755 2.42 / 841.47 4 26
4 13 993.32 20 14.89 1682 501 2.92 / 841.97 8 42
5 13 326.08 20 15.00 779 234 3.15 / 842.20 18 245
6 8 0.00 165 15.07 223 555 3.71 / 842.76 245 245
7 14 0.00 1 15.07 223 3 3.71 / 842.76 245 245
Average= 3.96
(KJ/cycle)

Cycle 211 GMT 23/ 7/2024 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 34 15.02 479 245 0.24 / 835.65 2 11
2 7 2004.36 32 14.88 2913 1387 1.63 / 837.03 2 17
3 13 1535.04 20 14.86 2373 705 2.34 / 837.74 4 25
4 13 1037.16 20 14.88 1737 517 2.85 / 838.26 8 40
5 13 343.12 20 15.00 807 242 3.10 / 838.50 17 245
6 8 -0.08 165 15.07 222 552 3.65 / 839.05 245 245
Average= 3.96
(KJ/cycle)

Cycle 210 GMT 13/ 7/2024 23:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 34 15.02 460 235 0.23 / 831.95 2 11
2 7 2004.72 32 14.87 2930 1394 1.63 / 833.34 2 17
3 13 1549.40 20 14.85 2392 710 2.34 / 834.05 3 22
4 13 1058.60 20 14.87 1787 531 2.87 / 834.59 7 36
5 13 390.84 20 14.98 872 261 3.13 / 834.85 15 76
6 8 0.12 165 15.07 223 555 3.69 / 835.40 35 245
Average= 3.96
(KJ/cycle)

Cycle 209 GMT 4/ 7/2024 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 34 15.03 432 221 0.22 / 828.15 2 11
2 7 2011.80 32 14.88 2911 1386 1.61 / 829.53 2 17
3 13 1550.76 20 14.86 2389 710 2.32 / 830.24 4 23
4 13 1061.08 20 14.86 1773 527 2.84 / 830.77 7 36
5 13 522.76 20 14.96 1065 319 3.16 / 831.09 16 68
6 13 28.40 20 15.07 309 93 3.26 / 831.18 33 245
7 8 -0.08 165 15.06 214 532 3.79 / 831.72 245 245
Average= 3.96
(KJ/cycle)

Cycle 208 GMT 24/ 6/2024 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 34 15.03 439 224 0.22 / 824.32 2 10
2 7 2002.80 32 14.88 2904 1383 1.61 / 825.70 2 15
3 13 1681.72 20 14.86 2543 756 2.36 / 826.46 3 23
4 13 1153.84 20 14.87 1885 561 2.92 / 827.02 7 34
5 13 444.12 20 14.98 954 286 3.21 / 827.30 13 54
6 13 28.16 20 15.08 315 95 3.30 / 827.40 29 245
7 8 0.20 165 15.07 213 530 3.83 / 827.93 245 244
Average= 3.96
(KJ/cycle)

Cycle 207 GMT 14/ 6/2024 5:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 34 15.03 454 232 0.23 / 820.45 2 9
2 7 2010.84 32 14.88 2916 1388 1.62 / 821.84 2 16
3 13 1684.04 20 14.85 2528 751 2.37 / 822.59 3 22
4 13 1161.96 20 14.86 1892 562 2.93 / 823.15 6 34
5 13 460.40 20 14.97 983 294 3.23 / 823.45 13 51
6 13 60.52 20 15.07 363 109 3.34 / 823.56 28 245
7 8 -0.16 165 15.07 215 535 3.87 / 824.09 245 244
8 14 -0.16 1 15.07 212 3 3.88 / 824.09 244 244
Average= 3.96
(KJ/cycle)

Cycle 206 GMT 4/ 6/2024 8:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 34 15.02 447 228 0.23 / 816.62 2 9
2 7 2005.28 32 14.89 2903 1383 1.61 / 818.01 2 16
3 13 1694.52 20 14.85 2546 756 2.37 / 818.76 3 22
4 13 1016.24 20 14.89 1703 507 2.87 / 819.27 6 33
5 13 496.56 20 14.97 1001 300 3.17 / 819.57 12 50
6 13 70.60 20 15.07 382 115 3.29 / 819.68 27 245
7 8 0.04 165 15.07 214 532 3.82 / 820.22 245 244
8 14 0.04 1 15.07 224 3 3.83 / 820.22 244 244
Average= 3.96
(KJ/cycle)

Cycle 205 GMT 25/ 5/2024 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 34 15.05 425 217 0.22 / 812.86 2 9
2 7 2007.28 32 14.88 2904 1383 1.60 / 814.25 2 16
3 13 1676.88 20 14.85 2541 755 2.35 / 815.00 3 22
4 13 1011.84 20 14.89 1689 503 2.86 / 815.50 6 31
5 13 330.60 20 15.01 796 239 3.10 / 815.74 12 48
6 13 70.52 20 15.07 380 115 3.21 / 815.86 28 245
7 8 -0.08 165 15.07 216 537 3.75 / 816.39 244 244
Average= 3.96
(KJ/cycle)

Cycle 204 GMT 15/ 5/2024 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 34 15.03 440 225 0.22 / 809.11 2 8
2 7 2003.44 32 14.88 2899 1380 1.61 / 810.49 2 15
3 13 1673.84 20 14.86 2531 752 2.36 / 811.24 3 20
4 13 1014.56 20 14.89 1700 506 2.86 / 811.75 5 29
5 13 358.28 20 15.01 819 246 3.11 / 811.99 11 45
6 13 84.84 20 15.07 406 122 3.23 / 812.12 25 245
7 8 -0.20 165 15.07 211 525 3.76 / 812.64 244 244
8 14 -0.20 1 15.07 220 3 3.76 / 812.65 244 244
Average= 3.96
(KJ/cycle)

Cycle 203 GMT 5/ 5/2024 14:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 34 15.04 442 226 0.23 / 805.30 2 8
2 7 2006.60 32 14.88 2914 1388 1.61 / 806.69 2 14
3 13 1542.40 20 14.87 2372 705 2.32 / 807.39 3 21
4 13 1055.00 20 14.88 1759 523 2.84 / 807.92 5 30
5 13 530.76 20 14.96 1053 315 3.16 / 808.23 11 46
6 13 62.60 20 15.06 388 117 3.27 / 808.35 23 245
7 8 -0.12 165 15.07 216 537 3.81 / 808.89 244 244
Average= 3.97
(KJ/cycle)

Cycle 202 GMT 25/ 4/2024 17:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 34 15.03 433 221 0.22 / 801.50 2 8
2 7 2008.44 33 14.87 2915 1430 1.65 / 802.93 2 15
3 13 1679.28 20 14.85 2535 753 2.40 / 803.69 3 20
4 13 993.36 20 14.89 1685 502 2.91 / 804.19 5 27
5 13 331.40 20 15.01 795 239 3.15 / 804.43 10 42
6 13 48.76 20 15.07 378 114 3.26 / 804.54 22 245
7 8 -0.08 165 15.08 214 532 3.79 / 805.07 244 244
Average= 3.97
(KJ/cycle)

Cycle 201 GMT 15/ 4/2024 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 34 15.03 460 235 0.24 / 797.78 2 7
2 7 2003.96 32 14.88 2910 1386 1.62 / 799.16 2 14
3 13 1538.84 20 14.87 2360 702 2.32 / 799.87 3 20
4 13 1039.60 20 14.88 1746 520 2.84 / 800.38 5 27
5 13 368.40 20 15.00 835 250 3.09 / 800.64 9 39
6 13 44.08 20 15.07 373 112 3.21 / 800.75 20 245
7 8 -0.16 165 15.07 215 535 3.74 / 801.28 244 244
Average= 3.97
(KJ/cycle)

Cycle 200 GMT 5/ 4/2024 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 34 15.04 460 235 0.24 / 793.94 2 8
2 7 2009.44 32 14.88 2911 1386 1.62 / 795.33 2 15
3 13 1677.20 20 14.85 2532 752 2.37 / 796.08 3 19
4 13 996.88 20 14.89 1697 505 2.88 / 796.58 5 26
5 13 488.24 20 14.97 1010 302 3.18 / 796.89 9 38
6 13 65.24 20 15.07 410 124 3.30 / 797.01 19 245
7 8 -0.04 165 15.07 214 532 3.84 / 797.54 244 244
Average= 3.97
(KJ/cycle)

Cycle 199 GMT 26/ 3/2024 23:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 34 15.04 427 218 0.22 / 790.03 2 7
2 7 2007.08 33 14.88 2908 1428 1.65 / 791.46 2 14
3 13 1689.00 20 14.84 2551 757 2.40 / 792.21 3 20
4 13 1134.96 20 14.87 1885 561 2.96 / 792.77 5 26
5 13 428.60 20 14.99 918 275 3.24 / 793.05 9 37
6 13 51.44 20 15.07 399 120 3.36 / 793.17 18 245
7 8 -0.04 165 15.07 216 537 3.90 / 793.71 245 244
Average= 3.97
(KJ/cycle)

Cycle 198 GMT 17/ 3/2024 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 34 15.05 423 216 0.22 / 786.27 2 7
2 7 2003.56 32 14.88 2895 1378 1.59 / 787.65 2 13
3 13 1689.32 20 14.85 2554 759 2.35 / 788.41 3 18
4 13 1023.32 20 14.88 1722 512 2.87 / 788.92 4 26
5 13 366.76 20 15.00 845 253 3.12 / 789.17 8 34
6 13 46.88 20 15.07 392 118 3.24 / 789.29 17 245
7 8 -0.16 165 15.08 209 520 3.76 / 789.81 244 244
Average= 3.97
(KJ/cycle)

Cycle 197 GMT 7/ 3/2024 4:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 34 15.06 449 230 0.23 / 782.43 2 7
2 7 2003.60 32 14.88 2896 1379 1.61 / 783.81 2 13
3 13 1665.04 20 14.85 2538 754 2.36 / 784.56 3 18
4 13 1129.76 20 14.87 1864 554 2.92 / 785.12 4 26
5 13 426.88 20 14.99 912 273 3.19 / 785.39 8 34
6 13 50.92 20 15.07 386 116 3.31 / 785.51 17 76
7 8 0.04 165 15.08 217 540 3.85 / 786.05 245 244
8 14 0.04 1 15.07 226 3 3.85 / 786.05 244 244
Average= 3.97
(KJ/cycle)

Cycle 196 GMT 26/ 2/2024 6:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 34 15.06 428 219 0.22 / 778.57 2 7
2 7 2005.80 32 14.89 2896 1380 1.60 / 779.95 2 13
3 13 1679.80 20 14.85 2555 759 2.36 / 780.71 3 18
4 13 1143.80 20 14.87 1869 556 2.91 / 781.26 4 24
5 13 456.16 20 14.98 952 285 3.20 / 781.55 8 32
6 13 51.52 20 15.08 393 119 3.32 / 781.67 15 54
7 8 -0.20 165 15.08 214 532 3.85 / 782.20 36 244
8 14 -0.20 1 15.07 219 3 3.85 / 782.20 244 244
Average= 3.97
(KJ/cycle)

Cycle 195 GMT 16/ 2/2024 8:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 34 15.03 463 237 0.24 / 774.79 2 7
2 7 2011.64 33 14.87 2907 1426 1.66 / 776.22 2 13
3 13 1533.08 20 14.87 2367 704 2.37 / 776.93 3 18
4 13 1033.20 20 14.88 1758 523 2.89 / 777.45 4 25
5 13 347.76 20 15.01 807 242 3.13 / 777.69 8 31
6 13 50.48 20 15.07 396 119 3.25 / 777.81 15 54
7 8 0.00 165 15.08 215 535 3.79 / 778.34 35 244
8 14 0.00 1 15.08 218 3 3.79 / 778.35 244 244
Average= 3.97
(KJ/cycle)

Cycle 194 GMT 6/ 2/2024 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 34 15.04 426 218 0.22 / 770.92 2 7
2 7 2004.80 32 14.89 2899 1381 1.60 / 772.31 2 13
3 13 1681.84 20 14.86 2544 756 2.36 / 773.06 3 17
4 13 1013.32 20 14.89 1701 507 2.86 / 773.57 4 25
5 13 497.44 20 14.97 1041 312 3.17 / 773.88 7 30
6 13 54.80 20 15.07 404 122 3.30 / 774.00 13 48
7 8 -0.20 165 15.07 224 557 3.85 / 774.56 32 244
Average= 3.97
(KJ/cycle)

Cycle 193 GMT 27/ 1/2024 13: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 34 15.05 433 222 0.22 / 767.16 2 7
2 7 2002.92 32 14.88 2903 1382 1.60 / 768.54 2 13
3 13 1541.72 20 14.86 2387 709 2.31 / 769.25 2 17
4 13 1059.20 20 14.88 1772 527 2.84 / 769.78 4 22
5 13 392.48 20 15.00 879 264 3.10 / 770.04 7 29
6 13 45.92 20 15.07 399 120 3.22 / 770.16 12 46
7 8 -0.12 165 15.07 218 542 3.77 / 770.71 30 244
Average= 3.97
(KJ/cycle)

Cycle 192 GMT 17/ 1/2024 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 34 15.05 433 222 0.22 / 763.23 2 6
2 7 2003.72 32 14.89 2894 1379 1.60 / 764.61 2 12
3 13 1679.84 20 14.86 2537 754 2.35 / 765.36 2 16
4 13 1012.72 20 14.89 1714 510 2.86 / 765.87 4 24
5 13 493.80 20 14.98 1014 304 3.17 / 766.18 6 28
6 13 63.44 20 15.07 412 124 3.29 / 766.30 11 44
7 13 15.92 20 15.08 321 97 3.39 / 766.40 29 244
8 8 -0.04 165 15.07 217 540 3.93 / 766.94 244 244
9 14 -0.04 1 15.07 212 3 3.93 / 766.94 244 244
Average= 3.97
(KJ/cycle)

Cycle 191 GMT 7/ 1/2024 17:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 34 15.04 459 235 0.23 / 759.39 2 6
2 7 2006.80 32 14.89 2910 1387 1.62 / 760.77 2 12
3 13 1543.52 20 14.87 2375 706 2.33 / 761.48 2 17
4 13 1045.00 20 14.89 1743 519 2.85 / 762.00 4 22
5 13 515.92 20 14.98 1028 308 3.15 / 762.31 6 27
6 13 59.68 20 15.07 412 124 3.28 / 762.43 10 42
7 8 -0.08 165 15.07 230 572 3.85 / 763.00 25 244
8 14 -0.08 1 15.07 214 3 3.85 / 763.01 244 244
Average= 3.97
(KJ/cycle)

Cycle 190 GMT 28/12/2023 19:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 34 15.03 469 240 0.24 / 755.46 2 6
2 7 2006.40 32 14.89 2913 1388 1.63 / 756.85 2 12
3 13 1692.32 20 14.86 2555 759 2.39 / 757.61 2 17
4 13 1163.72 20 14.87 1903 566 2.95 / 758.17 3 21
5 13 450.88 20 14.99 975 292 3.25 / 758.46 6 26
6 13 52.72 20 15.08 395 119 3.36 / 758.58 10 39
7 8 -0.04 165 15.08 229 570 3.93 / 759.15 27 244
Average= 3.97
(KJ/cycle)

Cycle 189 GMT 18/12/2023 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 34 15.04 461 236 0.24 / 751.68 2 6
2 7 2007.84 32 14.88 2905 1383 1.62 / 753.06 2 13
3 13 1526.92 20 14.87 2369 705 2.32 / 753.77 2 17
4 13 1029.96 20 14.88 1750 521 2.84 / 754.29 3 22
5 13 349.68 20 15.01 822 247 3.09 / 754.54 6 25
6 13 38.56 20 15.08 392 118 3.21 / 754.65 9 39
7 8 -0.04 165 15.08 227 565 3.77 / 755.22 25 244
Average= 3.97
(KJ/cycle)

Cycle 188 GMT 8/12/2023 23:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 34 15.03 474 242 0.24 / 747.88 2 6
2 7 2003.40 32 14.89 2898 1381 1.62 / 749.26 2 11
3 13 1673.76 20 14.85 2547 756 2.38 / 750.01 2 17
4 13 993.88 20 14.89 1711 510 2.89 / 750.52 3 21
5 13 321.68 20 15.02 796 239 3.13 / 750.76 5 24
6 13 32.00 20 15.08 379 114 3.24 / 750.88 10 37
7 8 0.08 165 15.08 228 567 3.81 / 751.44 24 244
Average= 3.98
(KJ/cycle)

Cycle 187 GMT 29/11/2023 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 34 15.03 461 236 0.24 / 743.95 2 6
2 7 2004.32 32 14.88 2900 1381 1.62 / 745.33 2 11
3 13 1541.52 20 14.87 2377 707 2.32 / 746.04 2 16
4 13 1200.80 20 14.86 1964 584 2.91 / 746.62 3 20
5 13 474.48 20 14.98 1003 300 3.21 / 746.92 5 24
6 13 29.80 20 15.08 385 116 3.32 / 747.04 9 35
7 8 0.12 165 15.07 240 597 3.92 / 747.63 20 244
Average= 3.98
(KJ/cycle)

Cycle 186 GMT 19/11/2023 4:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 34 15.04 463 237 0.24 / 740.10 2 7
2 7 2008.92 32 14.89 2895 1379 1.62 / 741.48 2 11
3 13 1542.64 20 14.87 2374 706 2.32 / 742.19 2 17
4 13 1053.92 20 14.88 1752 521 2.84 / 742.71 3 20
5 13 523.24 20 14.97 1070 320 3.16 / 743.03 5 25
6 13 32.76 20 15.08 379 114 3.28 / 743.14 9 33
7 8 -0.24 165 15.07 230 572 3.85 / 743.71 21 244
Average= 3.98
(KJ/cycle)

Cycle 185 GMT 9/11/2023 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 34 15.04 462 236 0.24 / 736.18 2 6
2 7 2003.84 32 14.89 2899 1381 1.62 / 737.56 2 10
3 13 1672.36 20 14.86 2536 754 2.37 / 738.31 2 16
4 13 1150.12 20 14.87 1904 566 2.94 / 738.88 3 19
5 13 437.00 20 14.99 957 287 3.22 / 739.17 4 23
6 13 28.16 20 15.09 372 112 3.34 / 739.28 9 30
7 8 0.08 165 15.08 235 585 3.92 / 739.86 19 244
Average= 3.98
(KJ/cycle)

Cycle 184 GMT 30/10/2023 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 34 15.04 445 228 0.23 / 732.32 2 6
2 7 2002.88 32 14.89 2910 1387 1.61 / 733.70 2 12
3 13 1667.88 20 14.86 2512 747 2.36 / 734.45 2 15
4 13 996.72 20 14.90 1686 502 2.86 / 734.95 3 18
5 13 469.68 20 14.99 984 295 3.16 / 735.25 4 23
6 13 25.04 20 15.09 360 109 3.27 / 735.36 8 30
7 8 0.04 165 15.08 236 587 3.85 / 735.94 17 244
Average= 3.98
(KJ/cycle)

Cycle 183 GMT 20/10/2023 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 34 15.04 466 238 0.24 / 728.56 2 6
2 7 2013.80 33 14.88 2918 1433 1.67 / 729.99 2 12
3 13 1539.92 20 14.87 2379 708 2.38 / 730.70 2 15
4 13 1045.52 20 14.89 1744 519 2.90 / 731.22 3 18
5 13 364.56 20 15.02 824 248 3.15 / 731.47 4 22
6 8 0.08 165 15.08 249 620 3.77 / 732.09 9 245
Average= 3.98
(KJ/cycle)

Cycle 182 GMT 10/10/2023 13:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 34 15.04 473 242 0.24 / 724.82 2 6
2 7 2005.36 32 14.88 2911 1386 1.63 / 726.21 2 11
3 13 1545.40 20 14.87 2378 707 2.34 / 726.91 2 15
4 13 1049.92 20 14.89 1747 520 2.86 / 727.43 3 18
5 13 377.56 20 15.01 870 261 3.12 / 727.70 4 21
6 8 0.08 165 15.09 252 627 3.74 / 728.32 8 245
Average= 3.98
(KJ/cycle)

Cycle 181 GMT 30/ 9/2023 15:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 34 15.04 460 235 0.24 / 720.88 2 6
2 7 2005.24 32 14.89 2915 1389 1.62 / 722.26 2 10
3 13 1676.24 20 14.86 2540 755 2.38 / 723.02 2 14
4 13 1144.92 20 14.88 1872 557 2.94 / 723.58 3 18
5 13 448.32 20 15.00 966 290 3.23 / 723.87 4 20
6 13 47.76 20 15.09 401 121 3.35 / 723.99 7 25
7 8 0.12 165 15.08 238 592 3.94 / 724.58 12 245
Average= 3.98
(KJ/cycle)

Cycle 180 GMT 20/ 9/2023 18:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 34 15.04 457 234 0.23 / 716.98 2 6
2 7 2002.84 32 14.90 2907 1386 1.62 / 718.37 2 10
3 13 1678.00 20 14.86 2540 755 2.37 / 719.12 2 14
4 13 1016.88 20 14.90 1723 513 2.89 / 719.64 3 18
5 13 497.68 20 14.99 1013 304 3.19 / 719.94 4 20
6 13 27.40 20 15.09 354 107 3.30 / 720.05 6 23
7 8 0.00 165 15.08 239 595 3.89 / 720.64 10 245
Average= 3.98
(KJ/cycle)

Cycle 179 GMT 10/ 9/2023 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 34 15.05 460 235 0.24 / 713.06 2 6
2 7 2007.20 32 14.89 2904 1384 1.62 / 714.44 2 10
3 13 1680.00 20 14.86 2555 759 2.38 / 715.20 2 15
4 13 1144.20 20 14.88 1877 559 2.94 / 715.76 3 19
5 13 442.52 20 15.01 941 282 3.22 / 716.04 4 19
6 13 26.40 20 15.10 354 107 3.33 / 716.15 6 23
7 8 0.04 165 15.09 240 598 3.92 / 716.75 9 244
Average= 3.98
(KJ/cycle)

Cycle 178 GMT 31/ 8/2023 23: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 34 15.04 476 243 0.24 / 709.20 2 6
2 7 2005.52 32 14.90 2910 1387 1.63 / 710.59 2 11
3 13 1685.44 20 14.86 2570 764 2.39 / 711.35 2 14
4 13 1153.00 20 14.88 1887 562 2.96 / 711.91 3 18
5 13 441.56 20 15.01 937 281 3.24 / 712.20 4 19
6 8 0.28 165 15.09 252 627 3.87 / 712.82 6 245
Average= 3.98
(KJ/cycle)

Cycle 177 GMT 22/ 8/2023 1:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 34 15.05 471 241 0.24 / 705.32 2 6
2 7 2002.96 33 14.89 2908 1429 1.67 / 706.75 2 11
3 13 1528.00 20 14.88 2367 704 2.37 / 707.46 2 14
4 13 1040.76 20 14.89 1741 518 2.89 / 707.98 3 17
5 13 357.60 20 15.03 820 246 3.14 / 708.22 4 19
6 13 33.16 20 15.09 385 116 3.26 / 708.34 6 23
7 8 -0.16 165 15.08 249 620 3.88 / 708.96 6 245
Average= 3.98
(KJ/cycle)

Cycle 176 GMT 12/ 8/2023 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 34 15.05 460 235 0.24 / 701.55 2 6
2 7 2008.48 32 14.90 2920 1392 1.63 / 702.94 2 11
3 13 1558.72 20 14.87 2396 713 2.34 / 703.65 2 13
4 13 1063.64 20 14.89 1775 529 2.87 / 704.18 3 16
5 13 390.92 20 15.02 868 261 3.13 / 704.44 4 18
6 8 0.08 165 15.09 258 642 3.77 / 705.08 5 245
Average= 3.98
(KJ/cycle)

Cycle 175 GMT 2/ 8/2023 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 34 15.06 468 240 0.24 / 697.68 2 6
2 7 2004.56 32 14.89 2916 1389 1.63 / 699.07 2 11
3 13 1683.00 20 14.87 2546 757 2.39 / 699.82 2 12
4 13 1145.80 20 14.88 1876 558 2.94 / 700.38 3 16
5 13 441.72 20 15.01 950 285 3.23 / 700.67 3 17
6 8 0.04 165 15.09 259 645 3.87 / 701.31 4 245
Average= 3.98
(KJ/cycle)

Cycle 174 GMT 23/ 7/2023 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 34 15.05 465 238 0.24 / 693.73 2 6
2 7 2006.44 32 14.89 2909 1386 1.62 / 695.11 2 11
3 13 1535.36 20 14.88 2382 709 2.33 / 695.82 2 13
4 13 1053.20 20 14.89 1779 530 2.86 / 696.35 2 17
5 13 528.08 20 14.99 1062 318 3.18 / 696.67 3 18
6 13 56.72 20 15.09 422 127 3.31 / 696.80 5 21
7 8 0.12 165 15.08 255 634 3.94 / 697.43 7 245
8 14 0.12 1 15.08 230 3 3.95 / 697.44 245 245
Average= 3.99
(KJ/cycle)

Cycle 173 GMT 13/ 7/2023 10:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 34 15.05 472 242 0.24 / 689.76 2 6
2 7 2009.12 32 14.90 2919 1392 1.63 / 691.15 2 10
3 13 1670.20 20 14.87 2532 753 2.39 / 691.91 2 13
4 13 1142.40 20 14.89 1867 556 2.94 / 692.46 2 16
5 13 454.36 20 15.01 965 290 3.23 / 692.75 3 17
6 13 23.76 20 15.10 368 111 3.34 / 692.86 5 20
7 8 -0.16 165 15.09 252 627 3.97 / 693.49 8 245
Average= 3.99
(KJ/cycle)

Cycle 172 GMT 3/ 7/2023 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 34 15.04 469 240 0.24 / 685.81 2 5
2 7 2003.20 32 14.90 2917 1391 1.63 / 687.20 2 9
3 13 1541.84 20 14.88 2396 713 2.34 / 687.91 2 13
4 13 1045.20 20 14.89 1783 531 2.87 / 688.44 2 16
5 13 517.64 20 14.99 1064 319 3.19 / 688.76 3 17
6 13 25.88 20 15.10 377 114 3.31 / 688.88 5 20
7 8 0.12 165 15.08 259 644 3.95 / 689.52 11 245
Average= 3.99
(KJ/cycle)

Cycle 171 GMT 23/ 6/2023 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 34 15.04 476 243 0.24 / 681.84 2 5
2 7 2004.20 32 14.90 2919 1392 1.64 / 683.23 2 9
3 13 1539.96 20 14.87 2398 713 2.35 / 683.95 2 14
4 13 1056.88 20 14.89 1793 534 2.88 / 684.48 2 17
5 13 532.32 20 14.98 1100 330 3.21 / 684.81 3 18
6 13 30.12 20 15.10 387 117 3.33 / 684.93 4 19
7 8 -0.08 165 15.09 257 640 3.97 / 685.57 8 245
Average= 3.99
(KJ/cycle)

Cycle 170 GMT 13/ 6/2023 17: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 34 15.07 452 232 0.23 / 677.86 2 5
2 7 2014.04 32 14.90 2932 1398 1.63 / 679.25 2 10
3 13 1543.00 20 14.88 2386 710 2.34 / 679.96 2 13
4 13 1055.36 20 14.89 1788 532 2.87 / 680.50 2 16
5 13 532.44 20 14.98 1089 326 3.20 / 680.82 3 17
6 13 62.88 20 15.08 437 132 3.33 / 680.95 4 19
7 8 -0.04 165 15.08 259 644 3.97 / 681.60 7 245
Average= 3.99
(KJ/cycle)

Cycle 169 GMT 3/ 6/2023 19:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 34 15.05 467 239 0.24 / 673.86 2 4
2 7 2004.28 32 14.90 2910 1387 1.63 / 675.24 2 10
3 13 1680.32 20 14.86 2550 758 2.38 / 676.00 2 14
4 13 1154.72 20 14.88 1902 566 2.95 / 676.57 2 15
5 13 455.36 20 15.02 950 285 3.24 / 676.85 3 16
6 13 49.48 20 15.10 402 121 3.36 / 676.97 4 18
7 8 0.36 165 15.09 260 647 4.00 / 677.62 7 245
8 14 0.36 1 15.09 227 3 4.01 / 677.62 245 245
Average= 3.99
(KJ/cycle)

Cycle 168 GMT 24/ 5/2023 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 34 15.06 423 217 0.22 / 669.91 2 4
2 7 2003.44 33 14.89 2906 1428 1.64 / 671.33 2 9
3 13 1517.12 20 14.89 2345 698 2.34 / 672.03 2 12
4 13 1032.96 20 14.90 1746 520 2.86 / 672.55 2 15
5 13 501.48 20 15.00 1019 306 3.17 / 672.86 3 17
6 13 30.60 20 15.10 389 117 3.29 / 672.98 4 18
7 8 0.08 165 15.09 257 640 3.93 / 673.62 8 244
Average= 3.99
(KJ/cycle)

Cycle 167 GMT 14/ 5/2023 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 34 15.05 451 231 0.23 / 666.05 2 4
2 7 2006.64 32 14.90 2894 1380 1.61 / 667.43 2 8
3 13 1676.44 20 14.87 2527 752 2.36 / 668.18 2 13
4 13 1007.12 20 14.91 1718 512 2.87 / 668.69 2 15
5 13 352.00 20 15.05 815 245 3.12 / 668.94 3 15
6 13 38.00 20 15.11 377 114 3.23 / 669.05 4 17
7 8 0.00 165 15.10 256 638 3.87 / 669.69 6 245
Average= 3.99
(KJ/cycle)

Cycle 166 GMT 5/ 5/2023 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 34 15.05 466 238 0.24 / 662.11 2 4
2 7 2005.44 32 14.89 2911 1387 1.63 / 663.50 2 8
3 13 1542.16 20 14.88 2370 705 2.33 / 664.21 2 12
4 13 1037.56 20 14.89 1759 524 2.85 / 664.73 2 15
5 13 507.84 20 15.00 1033 310 3.16 / 665.04 3 17
6 13 53.68 20 15.10 409 124 3.29 / 665.16 4 18
7 8 0.16 165 15.09 263 655 3.94 / 665.82 6 244
Average= 3.99
(KJ/cycle)

Cycle 165 GMT 25/ 4/2023 4: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 34 15.06 459 235 0.24 / 658.07 2 4
2 7 2008.40 33 14.89 2917 1433 1.67 / 659.51 2 7
3 13 1674.60 20 14.87 2552 759 2.43 / 660.26 2 10
4 13 1131.28 20 14.88 1892 563 2.99 / 660.83 2 16
5 13 433.56 20 15.02 949 285 3.28 / 661.11 3 15
6 13 27.12 20 15.11 368 111 3.39 / 661.22 4 17
7 8 0.00 165 15.09 262 652 4.04 / 661.88 6 245
Average= 3.99
(KJ/cycle)

Cycle 164 GMT 15/ 4/2023 6:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 34 15.05 455 233 0.23 / 654.14 2 4
2 7 2003.88 32 14.89 2909 1386 1.62 / 655.52 2 8
3 13 1670.16 20 14.87 2527 752 2.37 / 656.27 2 12
4 13 984.04 20 14.91 1673 499 2.87 / 656.77 2 14
5 13 463.92 20 15.01 982 295 3.16 / 657.07 3 16
6 13 29.92 20 15.11 387 117 3.28 / 657.18 4 17
7 8 0.00 165 15.09 262 652 3.93 / 657.84 6 244
Average= 3.99
(KJ/cycle)

Cycle 163 GMT 5/ 4/2023 8:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 34 15.06 451 231 0.23 / 650.23 2 4
2 7 2003.76 32 14.90 2909 1387 1.62 / 651.61 2 7
3 13 1555.52 20 14.88 2389 711 2.33 / 652.33 2 11
4 13 1066.96 20 14.89 1803 537 2.87 / 652.86 2 14
5 13 377.16 20 15.04 851 256 3.12 / 653.12 3 14
6 13 37.68 20 15.11 398 120 3.24 / 653.24 4 16
7 8 -0.12 165 15.09 267 665 3.91 / 653.90 6 245
Average= 3.99
(KJ/cycle)

Cycle 162 GMT 26/ 3/2023 10:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 34 15.05 473 242 0.24 / 646.23 2 4
2 7 2008.20 33 14.89 2929 1439 1.68 / 647.67 2 7
3 13 1530.04 20 14.88 2360 702 2.38 / 648.37 2 11
4 13 1042.08 20 14.89 1766 526 2.91 / 648.90 2 13
5 13 522.64 20 14.99 1050 315 3.22 / 649.21 3 15
6 13 29.32 20 15.10 375 113 3.34 / 649.33 4 16
7 8 0.08 165 15.09 269 670 4.01 / 650.00 5 245
Average= 3.99
(KJ/cycle)

Cycle 161 GMT 16/ 3/2023 13: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 34 15.06 456 233 0.23 / 642.31 2 4
2 7 2003.96 33 14.90 2905 1428 1.66 / 643.74 2 8
3 13 1523.28 20 14.89 2340 697 2.36 / 644.44 2 11
4 13 1027.48 20 14.90 1747 521 2.88 / 644.96 2 14
5 13 350.16 20 15.04 833 251 3.13 / 645.21 3 14
6 13 37.68 20 15.10 392 118 3.25 / 645.33 3 15
7 8 0.00 165 15.09 266 662 3.91 / 645.99 5 244
Average= 3.99
(KJ/cycle)

Cycle 160 GMT 6/ 3/2023 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 34 15.06 462 237 0.24 / 638.40 2 3
2 7 2004.24 32 14.90 2905 1385 1.62 / 639.79 2 9
3 13 1672.24 20 14.87 2524 751 2.37 / 640.54 2 12
4 13 1011.64 20 14.92 1718 513 2.88 / 641.05 2 14
5 13 344.52 20 15.04 822 247 3.13 / 641.30 3 14
6 13 31.56 20 15.11 383 116 3.25 / 641.42 3 15
7 8 0.12 165 15.09 266 662 3.91 / 642.08 6 245
Average= 3.99
(KJ/cycle)

Cycle 159 GMT 24/ 2/2023 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 34 15.06 456 233 0.23 / 634.49 2 3
2 7 2002.52 32 14.91 2896 1382 1.62 / 635.87 2 6
3 13 1671.48 20 14.88 2544 757 2.37 / 636.62 2 9
4 13 1023.80 20 14.92 1710 510 2.88 / 637.13 2 14
5 13 362.00 20 15.05 823 248 3.13 / 637.38 2 13
6 13 36.32 20 15.11 384 116 3.25 / 637.50 3 15
7 8 0.08 165 15.09 269 670 3.92 / 638.17 4 244
Average= 3.99
(KJ/cycle)

Cycle 158 GMT 14/ 2/2023 19:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 34 15.06 457 234 0.23 / 630.55 2 3
2 7 2004.20 32 14.91 2916 1391 1.63 / 631.94 2 6
3 13 1683.00 20 14.88 2539 756 2.38 / 632.69 2 10
4 13 1025.52 20 14.92 1717 512 2.89 / 633.21 2 14
5 13 370.68 20 15.04 853 257 3.15 / 633.46 3 13
6 13 37.84 20 15.11 387 117 3.27 / 633.58 3 14
7 8 0.04 165 15.09 270 672 3.94 / 634.25 6 245
Average= 3.99
(KJ/cycle)

Cycle 157 GMT 4/ 2/2023 21:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 34 15.06 460 236 0.24 / 626.59 2 3
2 7 2004.00 32 14.92 2901 1385 1.62 / 627.98 2 5
3 13 1675.28 20 14.88 2555 760 2.38 / 628.74 2 9
4 13 1024.76 20 14.92 1744 520 2.90 / 629.26 2 13
5 13 359.48 20 15.04 856 257 3.16 / 629.51 3 13
6 13 30.88 20 15.11 380 115 3.27 / 629.63 3 14
7 8 -0.04 165 15.09 275 685 3.96 / 630.31 6 245
Average= 3.99
(KJ/cycle)

Cycle 156 GMT 26/ 1/2023 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 34 15.07 459 235 0.24 / 622.56 2 3
2 7 2004.88 32 14.92 2895 1382 1.62 / 623.94 2 5
3 13 1696.12 20 14.88 2573 766 2.38 / 624.71 2 9
4 13 1156.76 20 14.90 1885 562 2.94 / 625.27 2 12
5 13 456.56 20 15.03 965 290 3.23 / 625.56 2 12
6 13 24.04 20 15.12 367 111 3.35 / 625.67 3 14
7 8 -0.04 165 15.10 275 685 4.03 / 626.35 3 245
Average= 3.99
(KJ/cycle)

Cycle 155 GMT 16/ 1/2023 2:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 34 15.06 468 240 0.24 / 618.68 2 3
2 7 2005.80 32 14.91 2904 1386 1.63 / 620.07 2 5
3 13 1552.80 20 14.90 2373 707 2.33 / 620.77 2 10
4 13 1055.52 20 14.91 1758 524 2.86 / 621.30 2 11
5 13 387.84 20 15.05 855 257 3.11 / 621.56 2 12
6 13 20.32 20 15.13 350 106 3.22 / 621.66 3 14
7 8 -0.08 165 15.10 266 663 3.88 / 622.32 4 244
Average= 3.99
(KJ/cycle)

Cycle 154 GMT 6/ 1/2023 4:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 34 15.07 455 233 0.23 / 614.62 2 3
2 7 2006.76 32 14.91 2901 1384 1.62 / 616.00 2 6
3 13 1686.28 20 14.89 2546 758 2.38 / 616.76 2 9
4 13 1158.96 20 14.90 1899 566 2.94 / 617.33 2 11
5 13 454.04 20 15.03 973 292 3.23 / 617.62 2 12
6 13 24.44 20 15.12 382 116 3.35 / 617.74 3 14
7 8 0.20 165 15.10 283 705 4.05 / 618.44 4 245
Average= 3.99
(KJ/cycle)

Cycle 153 GMT 27/12/2022 6:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 34 15.06 457 234 0.23 / 610.59 2 3
2 7 2008.40 32 14.92 2910 1389 1.62 / 611.97 2 5
3 13 1678.12 20 14.89 2526 752 2.38 / 612.73 2 9
4 13 1142.00 20 14.91 1865 556 2.93 / 613.28 2 13
5 13 445.68 20 15.04 941 283 3.21 / 613.57 2 12
6 13 44.88 20 15.12 398 120 3.34 / 613.69 3 13
7 8 0.04 165 15.10 281 700 4.04 / 614.39 4 245
Average= 3.99
(KJ/cycle)

Cycle 152 GMT 17/12/2022 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 34 15.08 451 231 0.23 / 606.57 2 3
2 7 2003.56 32 14.91 2896 1382 1.61 / 607.95 2 5
3 13 1675.44 20 14.89 2531 754 2.37 / 608.70 2 8
4 13 1135.20 20 14.91 1870 558 2.92 / 609.26 2 12
5 13 417.96 20 15.04 935 281 3.21 / 609.54 2 12
6 13 19.64 20 15.13 358 108 3.31 / 609.65 3 13
7 8 0.08 165 15.10 282 703 4.02 / 610.35 4 245
Average= 3.99
(KJ/cycle)

Cycle 151 GMT 7/12/2022 11:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 34 15.07 464 238 0.24 / 602.63 2 3
2 7 2003.32 32 14.92 2900 1385 1.62 / 604.02 2 6
3 13 1674.44 20 14.89 2548 759 2.38 / 604.78 2 7
4 13 1011.24 20 14.93 1708 510 2.89 / 605.29 2 12
5 13 334.52 20 15.07 788 238 3.13 / 605.52 2 11
6 13 14.68 20 15.14 354 107 3.24 / 605.63 3 12
7 8 -0.08 165 15.11 282 703 3.94 / 606.33 5 245
Average= 3.99
(KJ/cycle)

Cycle 150 GMT 27/11/2022 13:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 34 15.07 467 239 0.24 / 598.57 2 3
2 7 2004.16 32 14.91 2913 1390 1.63 / 599.96 2 4
3 13 1676.32 20 14.89 2540 756 2.39 / 600.72 2 6
4 13 1148.84 20 14.90 1901 566 2.95 / 601.29 2 10
5 13 449.76 20 15.04 952 286 3.24 / 601.57 2 12
6 13 22.36 20 15.13 367 111 3.35 / 601.68 3 12
7 8 0.08 165 15.11 286 713 4.06 / 602.40 4 245
Average= 3.99
(KJ/cycle)

Cycle 149 GMT 17/11/2022 16:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 34 15.07 455 233 0.23 / 594.68 2 3
2 7 2002.84 32 14.92 2904 1386 1.62 / 596.07 2 6
3 13 1684.52 20 14.89 2543 757 2.38 / 596.83 2 7
4 13 1017.52 20 14.93 1717 513 2.89 / 597.34 2 10
5 13 354.20 20 15.07 820 247 3.14 / 597.59 2 12
6 8 0.20 165 15.12 299 746 3.88 / 598.33 3 245
Average= 3.99
(KJ/cycle)

Cycle 148 GMT 7/11/2022 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 34 15.08 454 233 0.23 / 590.61 2 3
2 7 2008.76 32 14.92 2915 1392 1.62 / 592.00 2 5
3 13 1671.96 20 14.89 2542 757 2.38 / 592.76 2 7
4 13 1144.52 20 14.91 1899 566 2.95 / 593.32 2 10
5 13 445.00 20 15.05 956 288 3.24 / 593.61 2 12
6 13 20.32 20 15.14 370 112 3.35 / 593.72 3 12
7 8 0.24 165 15.11 292 728 4.08 / 594.45 3 245
Average= 3.99
(KJ/cycle)

Cycle 147 GMT 28/10/2022 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 34 15.08 462 237 0.24 / 586.60 2 3
2 7 2008.48 33 14.91 2915 1434 1.67 / 588.03 2 6
3 13 1671.40 20 14.89 2552 760 2.43 / 588.79 2 8
4 13 1136.28 20 14.91 1868 557 2.99 / 589.35 2 10
5 13 408.76 20 15.06 896 270 3.26 / 589.62 2 11
6 8 -0.08 165 15.12 302 753 4.01 / 590.38 2 245
Average= 3.99
(KJ/cycle)

Cycle 146 GMT 18/10/2022 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 34 15.07 475 243 0.24 / 582.72 2 3
2 7 2007.84 32 14.92 2908 1388 1.63 / 584.11 2 6
3 13 1541.00 20 14.91 2368 706 2.34 / 584.81 2 7
4 13 1057.52 20 14.93 1763 526 2.86 / 585.34 2 9
5 13 369.60 20 15.07 844 254 3.12 / 585.59 2 11
6 8 0.48 165 15.11 307 765 3.88 / 586.36 2 245
7 14 0.48 1 15.12 226 3 3.89 / 586.36 245 245
Average= 3.99
(KJ/cycle)

Cycle 145 GMT 9/10/2022 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 34 15.08 454 233 0.23 / 578.72 2 3
2 7 2003.48 32 14.92 2902 1386 1.62 / 580.11 2 4
3 13 1674.92 20 14.89 2530 753 2.37 / 580.86 2 6
4 13 1140.84 20 14.92 1876 560 2.93 / 581.42 2 8
5 13 441.32 20 15.05 944 284 3.22 / 581.70 2 11
6 8 -0.12 165 15.12 310 773 3.99 / 582.48 2 245
Average= 3.99
(KJ/cycle)

Cycle 144 GMT 29/ 9/2022 3:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 34 15.08 461 236 0.24 / 574.84 2 3
2 7 2009.60 33 14.91 2913 1433 1.67 / 576.27 2 6
3 13 1521.44 20 14.90 2369 706 2.38 / 576.98 2 6
4 13 1025.32 20 14.93 1721 514 2.89 / 577.49 2 9
5 13 333.40 20 15.07 807 243 3.13 / 577.73 2 10
6 8 0.00 165 15.12 302 753 3.89 / 578.49 2 245
Average= 3.99
(KJ/cycle)

Cycle 143 GMT 19/ 9/2022 5:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 34 15.07 462 237 0.24 / 570.97 2 2
2 7 2004.48 32 14.92 2900 1385 1.62 / 572.36 2 6
3 13 1537.08 20 14.90 2385 711 2.33 / 573.07 2 6
4 13 1049.64 20 14.93 1749 522 2.85 / 573.59 2 7
5 13 372.44 20 15.07 842 254 3.11 / 573.84 2 9
6 8 0.28 165 15.12 303 756 3.86 / 574.60 3 245
Average= 3.99
(KJ/cycle)

Cycle 142 GMT 9/ 9/2022 8: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 34 15.07 466 239 0.24 / 567.03 2 2
2 7 2007.84 32 14.92 2925 1397 1.64 / 568.43 2 4
3 13 1531.40 20 14.91 2381 710 2.35 / 569.14 2 5
4 13 1034.76 20 14.93 1743 520 2.87 / 569.66 2 8
5 13 512.16 20 15.03 1044 314 3.18 / 569.97 2 10
6 8 0.00 165 15.11 306 763 3.94 / 570.74 2 245
Average= 3.99
(KJ/cycle)

Cycle 141 GMT 30/ 8/2022 10:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 34 15.07 477 244 0.24 / 563.09 2 2
2 7 2003.80 32 14.92 2915 1392 1.64 / 564.48 2 6
3 13 1686.04 20 14.89 2552 760 2.40 / 565.24 2 5
4 13 1012.52 20 14.94 1718 513 2.91 / 565.76 2 8
5 13 348.04 20 15.07 832 251 3.16 / 566.01 2 8
6 8 0.08 165 15.12 316 788 3.95 / 566.79 2 245
Average= 3.99
(KJ/cycle)

Cycle 140 GMT 20/ 8/2022 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 34 15.07 484 248 0.25 / 559.08 2 2
2 7 2003.52 32 14.93 2914 1392 1.64 / 560.47 2 4
3 13 1689.88 20 14.89 2551 760 2.40 / 561.23 2 5
4 13 1012.32 20 14.94 1712 512 2.91 / 561.74 2 8
5 13 493.64 20 15.03 1018 306 3.22 / 562.05 2 9
6 8 0.12 165 15.11 319 795 4.01 / 562.85 2 245
Average= 3.99
(KJ/cycle)

Cycle 139 GMT 10/ 8/2022 14:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 34 15.07 480 246 0.25 / 555.00 2 2
2 7 2005.48 32 14.92 2923 1396 1.64 / 556.40 2 4
3 13 1687.36 20 14.89 2549 759 2.40 / 557.15 2 6
4 13 1144.80 20 14.92 1892 565 2.97 / 557.72 2 7
5 13 439.60 20 15.05 955 287 3.25 / 558.01 2 8
6 8 -0.16 165 15.11 330 823 4.08 / 558.83 2 245
7 14 -0.16 1 15.11 254 4 4.08 / 558.83 245 245
Average= 3.99
(KJ/cycle)

Cycle 138 GMT 31/ 7/2022 17:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 34 15.06 475 243 0.24 / 550.97 2 2
2 7 2010.00 32 14.93 2916 1393 1.64 / 552.36 2 4
3 13 1685.08 20 14.90 2546 759 2.40 / 553.12 2 4
4 13 1016.92 20 14.94 1709 511 2.91 / 553.63 2 6
5 13 496.44 20 15.04 1032 310 3.22 / 553.94 2 8
6 8 0.16 165 15.11 327 815 4.03 / 554.75 2 245
Average= 3.99
(KJ/cycle)

Cycle 137 GMT 21/ 7/2022 19:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 34 15.07 467 239 0.24 / 546.96 2 2
2 7 2009.80 32 14.93 2913 1392 1.63 / 548.35 2 4
3 13 1675.96 20 14.90 2537 756 2.39 / 549.11 2 5
4 13 1005.08 20 14.94 1721 514 2.90 / 549.62 2 7
5 13 496.68 20 15.04 1016 306 3.21 / 549.93 2 7
6 8 0.20 165 15.11 319 795 4.00 / 550.72 2 245
Average= 3.99
(KJ/cycle)

Cycle 136 GMT 11/ 7/2022 21:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 34 15.07 483 247 0.25 / 542.94 2 2
2 7 2004.68 32 14.93 2919 1395 1.64 / 544.33 2 4
3 13 1540.00 20 14.91 2377 709 2.35 / 545.04 2 4
4 13 1205.88 20 14.91 1958 584 2.93 / 545.63 2 6
5 13 477.80 20 15.04 1016 306 3.24 / 545.93 2 7
6 8 0.12 165 15.11 316 788 4.03 / 546.72 2 245
Average= 3.99
(KJ/cycle)

Cycle 135 GMT 2/ 7/2022 0:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 34 15.07 481 246 0.25 / 538.97 2 2
2 7 2004.88 32 14.94 2911 1392 1.64 / 540.36 2 7
3 13 1681.24 20 14.90 2541 757 2.40 / 541.11 2 6
4 13 1014.92 20 14.94 1719 514 2.91 / 541.63 2 7
5 13 340.16 20 15.08 826 249 3.16 / 541.88 2 5
6 8 -0.08 165 15.11 327 815 3.97 / 542.69 2 245
Average= 3.99
(KJ/cycle)

Cycle 134 GMT 22/ 6/2022 2:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 34 15.08 478 245 0.25 / 535.03 2 2
2 7 2011.56 33 14.92 2919 1437 1.68 / 536.47 2 4
3 13 1541.32 20 14.90 2378 709 2.39 / 537.18 2 5
4 13 1047.96 20 14.93 1779 531 2.92 / 537.71 2 7
5 13 235.16 20 15.10 688 208 3.13 / 537.92 2 6
6 8 -0.04 165 15.12 322 803 3.93 / 538.72 2 245
Average= 3.99
(KJ/cycle)

Cycle 133 GMT 12/ 6/2022 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 34 15.07 490 251 0.25 / 531.06 2 2
2 7 2002.36 32 14.93 2899 1385 1.64 / 532.45 2 6
3 13 1661.00 20 14.90 2513 749 2.38 / 533.20 2 6
4 13 1129.56 20 14.93 1857 555 2.94 / 533.75 2 7
5 13 285.20 20 15.10 742 224 3.16 / 533.97 2 5
6 8 -0.04 165 15.12 325 811 3.97 / 534.79 2 245
Average= 3.99
(KJ/cycle)

Cycle 132 GMT 2/ 6/2022 6:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 34 15.07 460 236 0.24 / 527.10 2 2
2 7 2002.48 32 14.94 2897 1385 1.62 / 528.48 2 4
3 13 1663.32 20 14.91 2505 747 2.37 / 529.23 2 5
4 13 1132.80 20 14.92 1878 560 2.93 / 529.79 2 7
5 13 298.16 20 15.09 758 229 3.16 / 530.02 2 5
6 8 0.08 165 15.12 317 791 3.95 / 530.81 2 245
Average= 3.99
(KJ/cycle)

Cycle 131 GMT 23/ 5/2022 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 34 15.09 454 233 0.23 / 523.11 2 2
2 7 2004.16 32 14.94 2896 1385 1.62 / 524.49 2 5
3 13 1538.80 20 14.92 2377 709 2.33 / 525.20 2 4
4 13 1059.12 20 14.93 1764 527 2.85 / 525.73 2 6
5 13 374.08 20 15.07 852 257 3.11 / 525.99 2 6
6 13 14.80 20 15.14 350 106 3.22 / 526.09 2 7
7 8 -0.12 165 15.11 309 770 3.99 / 526.86 2 245
Average= 3.99
(KJ/cycle)

Cycle 130 GMT 13/ 5/2022 11:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 34 15.08 463 237 0.24 / 519.23 2 2
2 7 2003.72 32 14.94 2902 1387 1.62 / 520.61 2 4
3 13 1542.80 20 14.92 2365 706 2.33 / 521.32 2 5
4 13 1055.56 20 14.94 1757 525 2.86 / 521.84 2 6
5 13 374.00 20 15.07 861 260 3.11 / 522.10 2 5
6 8 0.20 165 15.12 308 768 3.88 / 522.87 2 245
7 14 0.20 1 15.12 283 4 3.89 / 522.88 245 245
Average= 3.99
(KJ/cycle)

Cycle 129 GMT 3/ 5/2022 13:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 34 15.08 449 230 0.23 / 515.11 2 2
2 7 2004.72 33 14.93 2902 1430 1.66 / 516.54 2 5
3 13 1675.84 20 14.90 2553 761 2.42 / 517.30 2 5
4 13 1144.28 20 14.92 1898 566 2.99 / 517.86 2 6
5 13 287.04 20 15.09 756 228 3.22 / 518.09 2 5
6 13 27.60 20 15.15 374 113 3.33 / 518.20 2 7
7 8 0.00 165 15.11 315 785 4.11 / 518.99 2 245
Average= 3.99
(KJ/cycle)

Cycle 128 GMT 23/ 4/2022 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 34 15.06 488 250 0.25 / 510.99 2 2
2 7 2005.60 33 14.93 2908 1433 1.68 / 512.42 2 3
3 13 1533.76 20 14.92 2359 704 2.39 / 513.12 2 5
4 13 1188.68 20 14.91 1934 577 2.96 / 513.70 2 5
5 13 448.76 20 15.05 952 287 3.25 / 513.99 2 6
6 13 51.80 20 15.14 403 122 3.37 / 514.11 2 7
7 8 -0.12 165 15.11 308 768 4.14 / 514.88 2 245
Average= 3.99
(KJ/cycle)

Cycle 127 GMT 13/ 4/2022 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 34 15.07 468 240 0.24 / 506.80 2 2
2 7 2004.48 32 14.93 2907 1389 1.63 / 508.19 2 5
3 13 1544.56 20 14.91 2390 713 2.34 / 508.91 2 5
4 13 1197.96 20 14.91 1948 581 2.92 / 509.49 2 6
5 13 485.04 20 15.04 1022 307 3.23 / 509.79 2 6
6 13 23.08 20 15.14 393 119 3.35 / 509.91 2 6
7 8 0.28 165 15.10 330 822 4.17 / 510.74 2 245
Average= 3.99
(KJ/cycle)

Cycle 126 GMT 3/ 4/2022 20:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 34 15.08 462 237 0.24 / 502.73 2 2
2 3 1017.72 1 15.23 1784 27 0.26 / 502.76 2 3
3 7 2004.16 32 14.94 2930 1401 1.66 / 504.16 2 5
4 13 1550.56 20 14.91 2390 713 2.38 / 504.87 2 4
5 13 1049.64 20 14.93 1765 527 2.90 / 505.40 2 6
6 13 375.40 20 15.07 870 262 3.17 / 505.66 2 5
7 13 37.68 20 15.13 389 118 3.28 / 505.78 2 6
8 8 0.04 165 15.11 315 785 4.07 / 506.56 2 245
Average= 3.99
(KJ/cycle)

Cycle 125 GMT 24/ 3/2022 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 34 15.07 458 235 0.23 / 498.71 2 2
2 7 2007.20 33 14.93 2901 1429 1.66 / 500.14 2 3
3 13 1676.72 20 14.91 2533 755 2.42 / 500.89 2 5
4 13 1002.20 20 14.95 1689 505 2.92 / 501.40 2 5
5 13 200.28 20 15.12 625 189 3.11 / 501.59 2 4
6 13 36.56 20 15.14 391 118 3.23 / 501.70 2 6
7 8 -0.12 165 15.12 317 791 4.02 / 502.49 2 245
Average= 3.99
(KJ/cycle)

Cycle 124 GMT 15/ 3/2022 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 34 15.08 455 233 0.23 / 494.65 2 2
2 7 2003.72 32 14.94 2924 1398 1.63 / 496.05 2 4
3 13 1543.80 20 14.91 2398 715 2.35 / 496.76 2 5
4 13 1058.24 20 14.94 1768 528 2.87 / 497.29 2 6
5 13 369.84 20 15.07 860 259 3.13 / 497.55 2 4
6 13 18.80 20 15.14 378 114 3.25 / 497.67 2 6
7 8 0.24 165 15.11 323 805 4.05 / 498.47 2 245
Average= 3.99
(KJ/cycle)

Cycle 123 GMT 5/ 3/2022 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 34 15.08 458 235 0.23 / 490.61 2 2
2 7 2013.92 33 14.93 2925 1441 1.68 / 492.05 2 5
3 13 1542.08 20 14.91 2370 707 2.38 / 492.76 2 4
4 13 1057.28 20 14.93 1770 529 2.91 / 493.28 2 5
5 13 344.84 20 15.08 810 244 3.16 / 493.53 2 5
6 13 30.88 20 15.14 369 112 3.27 / 493.64 2 6
7 8 0.04 165 15.11 312 778 4.05 / 494.42 2 245
Average= 3.99
(KJ/cycle)

Cycle 122 GMT 23/ 2/2022 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 34 15.08 460 236 0.24 / 486.58 2 2
2 7 2006.84 32 14.94 2927 1399 1.64 / 487.98 2 4
3 13 1554.60 20 14.91 2419 721 2.36 / 488.70 2 4
4 13 1073.20 20 14.93 1815 542 2.90 / 489.24 2 5
5 13 391.52 20 15.06 896 270 3.17 / 489.51 2 4
6 8 0.32 165 15.12 321 801 3.97 / 490.31 2 49
7 14 0.32 13 15.10 325 64 4.03 / 490.37 32 245
Average= 3.99
(KJ/cycle)

Cycle 121 GMT 13/ 2/2022 7:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 34 15.08 458 235 0.23 / 482.47 2 2
2 7 2009.32 32 14.94 2932 1402 1.64 / 483.88 2 3
3 13 1679.64 20 14.91 2546 759 2.40 / 484.64 2 5
4 13 1142.80 20 14.92 1906 569 2.96 / 485.20 2 5
5 13 281.04 20 15.10 722 218 3.18 / 485.42 2 4
6 13 24.20 20 15.15 379 115 3.30 / 485.54 2 5
7 8 -0.04 165 15.12 322 803 4.10 / 486.34 2 245
Average= 3.99
(KJ/cycle)

Cycle 120 GMT 3/ 2/2022 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 34 15.09 436 224 0.22 / 478.30 2 2
2 7 2007.20 32 14.94 2915 1394 1.62 / 479.69 2 3
3 13 1682.56 20 14.91 2557 762 2.38 / 480.46 2 5
4 13 1152.00 20 14.93 1902 568 2.95 / 481.02 2 6
5 13 437.00 20 15.06 953 287 3.23 / 481.31 2 4
6 13 38.44 20 15.15 393 119 3.35 / 481.43 2 5
7 8 0.20 165 15.12 325 811 4.16 / 482.24 2 245
Average= 3.99
(KJ/cycle)

Cycle 119 GMT 24/ 1/2022 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 34 15.09 447 229 0.23 / 474.26 2 2
2 7 2007.20 32 14.94 2918 1395 1.62 / 475.66 2 4
3 13 1551.08 20 14.92 2414 720 2.34 / 476.38 2 5
4 13 1071.92 20 14.94 1783 533 2.88 / 476.91 2 6
5 13 393.24 20 15.07 900 271 3.15 / 477.18 2 4
6 13 23.80 20 15.15 364 110 3.26 / 477.29 2 5
7 8 0.00 165 15.12 313 781 4.04 / 478.07 2 245
8 14 0.00 1 15.12 295 4 4.04 / 478.08 245 245
Average= 3.98
(KJ/cycle)

Cycle 118 GMT 14/ 1/2022 14:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 34 15.08 460 236 0.24 / 470.11 2 2
2 7 2004.84 32 14.94 2910 1391 1.63 / 471.50 2 3
3 13 1690.12 20 14.91 2547 760 2.39 / 472.26 2 5
4 13 1165.84 20 14.93 1923 574 2.96 / 472.84 2 6
5 13 461.56 20 15.07 975 294 3.25 / 473.13 2 5
6 13 27.64 20 15.15 369 112 3.37 / 473.24 2 5
7 8 0.16 165 15.12 316 788 4.15 / 474.03 2 120
Average= 3.98
(KJ/cycle)

Cycle 117 GMT 4/ 1/2022 16:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 34 15.09 468 240 0.24 / 466.12 2 2
2 7 2005.48 32 14.94 2898 1385 1.63 / 467.51 2 4
3 13 1537.72 20 14.93 2376 709 2.34 / 468.21 2 5
4 13 1047.08 20 14.95 1752 524 2.86 / 468.74 2 5
5 13 340.08 20 15.09 807 244 3.10 / 468.98 2 4
6 13 25.88 20 15.16 364 110 3.21 / 469.09 2 5
7 8 -0.16 165 15.12 314 783 4.00 / 469.88 2 171
Average= 3.98
(KJ/cycle)

Cycle 116 GMT 25/12/2021 18:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 34 15.09 458 235 0.23 / 462.18 2 2
2 7 2004.68 33 14.94 2902 1431 1.67 / 463.61 2 6
3 13 1533.76 20 14.93 2360 705 2.37 / 464.31 2 4
4 13 1030.88 20 14.95 1750 523 2.89 / 464.84 2 5
5 13 341.84 20 15.09 819 247 3.14 / 465.08 2 4
6 8 -0.08 165 15.13 319 796 3.94 / 465.88 2 35
Average= 3.98
(KJ/cycle)

Cycle 115 GMT 15/12/2021 21: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 34 15.10 474 243 0.24 / 458.06 2 2
2 7 2009.04 32 14.94 2909 1391 1.63 / 459.45 2 4
3 13 1675.72 20 14.92 2539 758 2.39 / 460.20 2 4
4 13 1150.88 20 14.94 1884 563 2.95 / 460.77 2 5
5 13 439.40 20 15.08 932 281 3.24 / 461.05 2 5
6 13 19.68 20 15.16 358 109 3.34 / 461.16 2 5
7 8 0.12 165 15.13 315 786 4.13 / 461.94 2 74
Average= 3.98
(KJ/cycle)

Cycle 114 GMT 5/12/2021 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 34 15.09 459 235 0.24 / 454.06 2 2
2 7 2010.36 32 14.94 2919 1396 1.63 / 455.46 2 3
3 13 1678.92 20 14.91 2558 763 2.39 / 456.22 2 5
4 13 1135.40 20 14.94 1864 557 2.95 / 456.78 2 5
5 13 266.40 20 15.12 721 218 3.17 / 457.00 2 4
6 8 0.08 165 15.14 326 814 3.98 / 457.81 2 33
Average= 3.98
(KJ/cycle)

Cycle 113 GMT 26/11/2021 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 34 15.09 475 244 0.24 / 450.00 2 2
2 7 2003.20 32 14.95 2921 1397 1.64 / 451.39 2 4
3 13 1547.24 20 14.93 2389 713 2.35 / 452.11 2 5
4 13 1056.88 20 14.95 1774 530 2.88 / 452.64 2 5
5 13 378.92 20 15.08 881 266 3.15 / 452.90 2 4
6 8 0.00 165 15.13 322 804 3.95 / 453.71 2 30
7 14 0.00 25 15.11 324 122 4.08 / 453.83 17 68
Average= 3.98
(KJ/cycle)

Cycle 112 GMT 16/11/2021 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 34 15.09 466 239 0.24 / 446.07 2 2
2 7 2009.32 32 14.95 2905 1390 1.63 / 447.46 2 6
3 13 1526.20 20 14.94 2344 700 2.33 / 448.16 2 5
4 13 1044.92 20 14.96 1747 523 2.85 / 448.68 2 5
5 13 368.80 20 15.09 843 254 3.11 / 448.94 2 4
6 8 0.16 165 15.13 327 816 3.92 / 449.75 2 28
Average= 3.98
(KJ/cycle)

Cycle 111 GMT 6/11/2021 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 34 15.08 478 245 0.25 / 442.13 2 2
2 7 2009.80 32 14.95 2919 1396 1.64 / 443.53 2 4
3 13 1525.96 20 14.94 2357 704 2.35 / 444.23 2 4
4 13 1034.12 20 14.96 1739 520 2.87 / 444.75 2 6
5 13 363.40 20 15.09 832 251 3.12 / 445.01 2 4
6 8 0.08 165 15.13 330 824 3.94 / 445.83 2 28
Average= 3.98
(KJ/cycle)

Cycle 110 GMT 27/10/2021 8:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 34 15.08 470 241 0.24 / 438.17 2 2
2 7 2007.68 32 14.94 2920 1396 1.64 / 439.57 2 3
3 13 1536.92 20 14.93 2391 714 2.35 / 440.28 2 5
4 13 1049.48 20 14.96 1764 528 2.88 / 440.81 2 5
5 13 365.56 20 15.09 841 254 3.13 / 441.06 2 4
6 8 0.04 165 15.13 330 824 3.96 / 441.89 2 27
Average= 3.98
(KJ/cycle)

Cycle 109 GMT 17/10/2021 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 34 15.09 469 241 0.24 / 434.14 2 2
2 7 2004.80 32 14.96 2911 1394 1.63 / 435.54 2 4
3 13 1683.84 20 14.92 2541 758 2.39 / 436.30 2 5
4 13 1022.56 20 14.96 1757 526 2.92 / 436.82 2 6
5 13 498.76 20 15.06 1018 307 3.22 / 437.13 2 5
6 8 0.36 165 15.13 322 804 4.03 / 437.93 2 24
Average= 3.98
(KJ/cycle)

Cycle 108 GMT 7/10/2021 12:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 33 15.08 480 239 0.24 / 430.23 2 2
2 7 2003.24 32 14.95 2906 1390 1.63 / 431.62 2 4
3 13 1530.96 20 14.93 2353 703 2.33 / 432.32 2 3
4 13 1046.32 20 14.96 1757 526 2.86 / 432.85 2 5
5 13 348.12 20 15.10 827 250 3.11 / 433.10 2 4
6 8 -0.08 165 15.13 322 804 3.91 / 433.90 2 26
Average= 3.98
(KJ/cycle)

Cycle 107 GMT 27/ 9/2021 14:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 33 15.08 470 234 0.23 / 426.28 2 2
2 7 2007.24 32 14.95 2902 1388 1.62 / 427.67 2 3
3 13 1680.64 20 14.92 2538 757 2.38 / 428.43 2 5
4 13 997.60 20 14.97 1688 505 2.88 / 428.93 2 5
5 13 325.16 20 15.10 803 243 3.13 / 429.18 2 4
6 8 0.12 165 15.13 327 816 3.94 / 429.99 2 26
Average= 3.98
(KJ/cycle)

Cycle 106 GMT 17/ 9/2021 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 33 15.09 469 234 0.23 / 422.35 2 2
2 7 2003.80 32 14.96 2904 1390 1.62 / 423.74 2 3
3 13 1529.04 20 14.94 2370 708 2.33 / 424.45 2 4
4 13 1049.88 20 14.96 1758 526 2.86 / 424.97 2 5
5 13 375.44 20 15.09 862 260 3.12 / 425.23 2 4
6 8 -0.04 165 15.13 327 816 3.93 / 426.05 2 24
Average= 3.98
(KJ/cycle)

Cycle 105 GMT 7/ 9/2021 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 33 15.08 486 242 0.24 / 418.38 2 2
2 7 2005.16 32 14.96 2911 1394 1.64 / 419.77 2 3
3 13 1544.28 20 14.94 2381 711 2.35 / 420.49 2 4
4 13 1197.64 20 14.93 1945 581 2.93 / 421.07 2 5
5 13 322.96 20 15.10 782 236 3.16 / 421.30 2 4
6 8 0.12 165 15.13 325 811 3.98 / 422.11 2 23
Average= 3.98
(KJ/cycle)

Cycle 104 GMT 28/ 8/2021 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 33 15.08 465 231 0.23 / 414.30 2 2
2 7 2002.88 32 14.96 2919 1397 1.63 / 415.70 2 4
3 13 1674.36 20 14.93 2532 756 2.38 / 416.46 2 4
4 13 1144.48 20 14.94 1888 564 2.95 / 417.02 2 4
5 13 450.44 20 15.07 954 288 3.24 / 417.31 2 4
6 8 0.16 165 15.13 333 831 4.07 / 418.14 2 22
Average= 3.98
(KJ/cycle)

Cycle 103 GMT 19/ 8/2021 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 33 15.09 471 235 0.23 / 410.27 2 2
2 7 2009.16 32 14.95 2908 1391 1.63 / 411.66 2 3
3 13 1672.52 20 14.93 2522 753 2.38 / 412.42 2 3
4 13 1142.32 20 14.95 1877 561 2.94 / 412.98 2 4
5 13 428.52 20 15.08 934 282 3.22 / 413.26 2 4
6 8 0.12 165 15.13 325 811 4.03 / 414.07 2 23
Average= 3.98
(KJ/cycle)

Cycle 102 GMT 9/ 8/2021 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 33 15.08 472 235 0.23 / 406.33 2 2
2 7 2002.60 32 14.96 2898 1387 1.62 / 407.72 2 5
3 13 1669.52 20 14.93 2525 754 2.38 / 408.47 2 4
4 13 998.32 20 14.98 1697 508 2.88 / 408.98 2 5
5 13 344.68 20 15.10 825 249 3.13 / 409.23 2 4
6 8 0.16 165 15.13 324 809 3.94 / 410.04 2 22
Average= 3.98
(KJ/cycle)

Cycle 101 GMT 30/ 7/2021 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 33 15.09 474 236 0.24 / 402.40 2 2
2 7 2004.32 32 14.97 2908 1393 1.63 / 403.79 2 5
3 13 1540.72 20 14.94 2376 710 2.34 / 404.50 2 4
4 13 1044.96 20 14.96 1757 526 2.86 / 405.03 2 6
5 13 381.08 20 15.09 857 259 3.12 / 405.29 2 4
6 8 0.12 165 15.13 324 809 3.93 / 406.10 2 22
Average= 3.98
(KJ/cycle)

Cycle 100 GMT 20/ 7/2021 7: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 33 15.08 498 248 0.25 / 398.45 2 2
2 7 2011.00 32 14.96 2926 1401 1.65 / 399.86 2 3
3 13 1537.08 20 14.94 2372 709 2.36 / 400.56 2 4
4 13 1044.04 20 14.96 1771 530 2.89 / 401.09 2 5
5 13 368.44 20 15.09 846 255 3.14 / 401.35 2 4
6 8 -0.04 165 15.13 326 814 3.96 / 402.16 2 22
Average= 3.98
(KJ/cycle)

Cycle 99 GMT 10/ 7/2021 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 33 15.09 480 239 0.24 / 394.45 2 2
2 7 2005.92 32 14.96 2920 1398 1.64 / 395.85 2 4
3 13 1544.68 20 14.93 2387 713 2.35 / 396.56 2 5
4 13 1052.48 20 14.96 1785 534 2.88 / 397.09 2 4
5 13 375.36 20 15.09 860 260 3.14 / 397.35 2 4
6 8 0.04 165 15.13 342 854 4.00 / 398.21 2 22
Average= 3.98
(KJ/cycle)

Cycle 98 GMT 30/ 6/2021 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 33 15.10 482 240 0.24 / 390.46 2 2
2 7 2005.92 33 14.95 2912 1437 1.68 / 391.89 2 4
3 13 1530.00 20 14.94 2372 709 2.39 / 392.60 2 4
4 13 1022.88 20 14.96 1760 527 2.91 / 393.13 2 5
5 13 325.28 20 15.10 808 244 3.16 / 393.37 2 4
6 8 0.28 165 15.13 336 839 3.99 / 394.21 2 22
Average= 3.98
(KJ/cycle)

Cycle 97 GMT 20/ 6/2021 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 33 15.09 479 239 0.24 / 386.47 2 2
2 7 2005.00 32 14.96 2913 1395 1.63 / 387.86 2 4
3 13 1676.32 20 14.93 2555 763 2.40 / 388.62 2 3
4 13 1005.32 20 14.98 1730 518 2.91 / 389.14 2 5
5 13 327.36 20 15.11 795 240 3.15 / 389.38 2 3
6 8 0.08 165 15.14 333 832 3.99 / 390.21 2 23
Average= 3.98
(KJ/cycle)

Cycle 96 GMT 10/ 6/2021 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 33 15.08 490 244 0.24 / 382.45 2 2
2 7 2009.64 33 14.96 2925 1444 1.69 / 383.89 2 3
3 13 1521.20 20 14.94 2378 711 2.40 / 384.60 2 4
4 13 1181.32 20 14.94 1956 584 2.98 / 385.18 2 5
5 13 305.36 20 15.11 776 235 3.22 / 385.42 2 3
6 8 0.20 165 15.14 324 809 4.03 / 386.23 2 22
Average= 3.98
(KJ/cycle)

Cycle 95 GMT 31/ 5/2021 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 33 15.07 466 232 0.23 / 378.25 2 2
2 7 2009.00 32 14.97 2927 1402 1.63 / 379.65 2 3
3 13 1675.32 20 14.94 2534 757 2.39 / 380.41 2 3
4 13 1016.20 20 14.98 1721 516 2.91 / 380.92 2 4
5 13 488.68 20 15.07 1011 305 3.21 / 381.23 2 4
6 13 21.08 20 15.16 392 119 3.33 / 381.35 2 4
7 8 -0.12 165 15.13 343 856 4.19 / 382.20 2 27
Average= 3.98
(KJ/cycle)

Cycle 94 GMT 21/ 5/2021 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 33 15.07 511 254 0.25 / 374.20 2 2
2 7 2004.60 32 14.97 2913 1395 1.65 / 375.59 2 4
3 13 1532.40 20 14.95 2371 709 2.36 / 376.30 2 4
4 13 1059.52 20 14.95 1775 531 2.89 / 376.83 2 5
5 13 389.04 20 15.06 876 264 3.15 / 377.10 2 4
6 8 0.08 165 15.11 320 798 3.95 / 377.90 2 22
7 14 0.08 25 15.08 317 120 4.07 / 378.02 6 27
Average= 3.98
(KJ/cycle)

Cycle 93 GMT 11/ 5/2021 22:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 33 15.11 461 230 0.23 / 369.96 2 2
2 7 2011.56 33 14.96 2912 1438 1.67 / 371.39 2 4
3 13 1670.64 20 14.94 2535 757 2.42 / 372.15 2 4
4 13 970.32 20 14.98 1689 506 2.93 / 372.66 2 5
5 13 456.08 20 15.07 1002 302 3.23 / 372.96 2 4
6 13 21.12 20 15.16 398 121 3.35 / 373.08 2 4
7 8 0.04 165 15.12 347 866 4.22 / 373.94 2 25
Average= 3.98
(KJ/cycle)

Cycle 92 GMT 2/ 5/2021 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 33 15.10 475 237 0.24 / 365.99 2 2
2 7 2004.00 32 14.98 2912 1396 1.63 / 367.39 2 3
3 13 1676.24 20 14.94 2570 768 2.40 / 368.16 2 3
4 13 1002.92 20 14.99 1713 514 2.91 / 368.67 2 5
5 13 342.48 20 15.12 812 246 3.16 / 368.92 2 4
6 8 0.20 165 15.15 324 810 3.97 / 369.73 2 21
Average= 3.98
(KJ/cycle)

Cycle 91 GMT 22/ 4/2021 2:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 33 15.11 466 232 0.23 / 361.90 2 2
2 7 2010.44 33 14.96 2928 1445 1.68 / 363.34 2 4
3 13 1535.04 20 14.96 2371 709 2.39 / 364.05 2 3
4 13 902.16 20 15.01 1583 475 2.86 / 364.53 2 5
5 13 415.24 20 15.10 913 276 3.14 / 364.80 2 4
6 13 39.48 20 15.17 406 123 3.26 / 364.93 2 4
7 8 0.00 165 15.14 332 829 4.09 / 365.76 2 26
Average= 3.98
(KJ/cycle)

Cycle 90 GMT 12/ 4/2021 4:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 33 15.10 478 238 0.24 / 357.72 2 2
2 7 2003.84 32 14.97 2915 1396 1.63 / 359.11 2 3
3 13 1703.32 20 14.94 2601 777 2.41 / 359.89 2 4
4 13 1015.84 20 14.99 1726 517 2.93 / 360.41 2 5
5 13 490.56 20 15.08 1037 313 3.24 / 360.72 2 5
6 13 27.00 20 15.18 390 118 3.36 / 360.84 2 4
7 8 0.00 165 15.15 331 827 4.19 / 361.67 2 21
Average= 3.97
(KJ/cycle)

Cycle 89 GMT 2/ 4/2021 6:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 33 15.10 467 233 0.23 / 353.66 2 2
2 7 2008.12 32 14.96 2907 1392 1.62 / 355.05 2 5
3 13 1517.44 20 14.95 2381 712 2.34 / 355.76 2 4
4 13 1024.48 20 14.98 1761 528 2.86 / 356.29 2 5
5 13 321.48 20 15.11 811 245 3.11 / 356.54 2 4
6 13 28.72 20 15.17 385 117 3.23 / 356.65 2 3
7 8 -0.16 165 15.14 330 824 4.05 / 357.48 2 22
Average= 3.97
(KJ/cycle)

Cycle 88 GMT 23/ 3/2021 8:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 33 15.11 471 235 0.23 / 349.58 2 2
2 7 2002.16 33 14.97 2913 1439 1.67 / 351.02 2 3
3 13 1516.84 20 14.96 2375 711 2.38 / 351.73 2 4
4 13 1016.48 20 14.99 1732 519 2.90 / 352.25 2 5
5 13 328.40 20 15.12 805 243 3.15 / 352.49 2 4
6 13 29.36 20 15.18 383 116 3.26 / 352.61 2 3
7 8 0.08 165 15.14 328 819 4.08 / 353.43 2 21
Average= 3.97
(KJ/cycle)

Cycle 87 GMT 13/ 3/2021 11: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 33 15.11 480 239 0.24 / 345.49 2 2
2 7 2009.00 32 14.97 2924 1401 1.64 / 346.89 2 5
3 13 1543.48 20 14.96 2407 720 2.36 / 347.61 2 4
4 13 1043.88 20 14.98 1788 536 2.90 / 348.14 2 4
5 13 352.60 20 15.12 837 253 3.15 / 348.40 2 4
6 13 34.52 20 15.18 400 121 3.27 / 348.52 2 3
7 8 0.04 165 15.15 331 827 4.10 / 349.34 2 22
Average= 3.97
(KJ/cycle)

Cycle 86 GMT 3/ 3/2021 13:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 33 15.10 474 236 0.24 / 341.38 2 2
2 7 2004.04 32 14.97 2939 1408 1.64 / 342.79 2 3
3 13 1532.00 20 14.96 2397 717 2.36 / 343.51 2 4
4 13 1027.28 20 14.98 1755 526 2.89 / 344.03 2 4
5 13 353.84 20 15.11 865 261 3.15 / 344.29 2 4
6 13 36.80 20 15.18 402 122 3.27 / 344.41 2 4
7 8 0.08 165 15.14 333 832 4.10 / 345.25 2 19
Average= 3.97
(KJ/cycle)

Cycle 85 GMT 21/ 2/2021 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 33 15.12 475 237 0.24 / 337.20 2 2
2 7 2003.08 32 14.98 2904 1392 1.63 / 338.59 2 3
3 13 1677.80 20 14.95 2576 770 2.40 / 339.36 2 4
4 13 988.44 20 15.01 1698 510 2.91 / 339.87 2 4
5 13 452.68 20 15.10 991 299 3.21 / 340.17 2 3
6 13 22.32 20 15.19 394 120 3.33 / 340.29 2 3
7 8 0.00 165 15.15 342 855 4.18 / 341.14 2 17
Average= 3.97
(KJ/cycle)

Cycle 84 GMT 11/ 2/2021 17:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 32 15.13 477 231 0.23 / 333.20 2 2
2 10 1003.20 2 15.17 1749 53 0.28 / 333.25 2 3
3 3 951.12 -1 15.48 0 0 0.05 / 333.25 2 3
4 7 2005.44 32 14.97 2912 1395 1.68 / 334.65 2 5
5 13 1662.40 20 14.96 2526 756 2.43 / 335.40 2 4
6 13 957.68 20 15.01 1647 494 2.93 / 335.90 2 4
7 13 292.12 20 15.14 748 226 3.16 / 336.12 2 3
8 8 0.28 165 15.16 335 838 3.99 / 336.96 2 17
Average= 3.96
(KJ/cycle)

Cycle 83 GMT 1/ 2/2021 19:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 15.12 495 240 0.24 / 329.21 2 2
2 7 2006.40 32 14.98 2930 1405 1.64 / 330.61 2 3
3 13 1688.00 20 14.96 2561 766 2.41 / 331.38 2 4
4 13 1017.28 20 15.00 1751 525 2.94 / 331.90 2 3
5 13 335.96 20 15.14 817 247 3.18 / 332.15 2 3
6 8 0.28 165 15.17 326 816 4.00 / 332.97 2 17
Average= 3.96
(KJ/cycle)

Cycle 82 GMT 22/ 1/2021 22: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 32 15.13 485 235 0.23 / 325.18 2 2
2 3 1032.40 1 15.21 1815 28 0.26 / 325.20 2 3
3 7 2003.16 32 14.98 2928 1404 1.67 / 326.61 2 3
4 13 1527.56 20 14.97 2391 716 2.38 / 327.32 2 4
5 13 1031.88 20 14.99 1764 529 2.91 / 327.85 2 4
6 13 344.44 20 15.12 861 260 3.17 / 328.11 2 4
7 8 0.20 165 15.16 342 855 4.03 / 328.97 2 17
Average= 3.96
(KJ/cycle)

Cycle 81 GMT 13/ 1/2021 0:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 33 15.12 489 244 0.24 / 321.13 2 2
2 3 972.32 -1 15.47 0 0 0.00 / 321.13 2 2
3 3 1020.96 1 15.23 1805 27 0.27 / 321.16 2 3
4 7 2011.64 32 14.99 2921 1401 1.67 / 322.56 2 4
5 13 1538.68 20 14.97 2401 719 2.39 / 323.28 2 3
6 13 921.80 20 15.03 1604 482 2.87 / 323.76 2 5
7 13 562.40 20 15.08 1142 344 3.22 / 324.11 2 4
8 8 0.16 165 15.17 333 834 4.05 / 324.94 2 18
Average= 3.96
(KJ/cycle)

Cycle 80 GMT 3/ 1/2021 2:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 32 15.13 481 233 0.23 / 316.87 2 2
2 3 1030.28 1 15.21 1837 28 0.26 / 316.90 2 3
3 7 2003.20 32 14.98 2913 1396 1.66 / 318.30 2 3
4 13 1669.52 20 14.95 2557 765 2.42 / 319.06 2 4
5 13 1141.12 20 14.98 1886 565 2.99 / 319.63 2 4
6 13 423.64 20 15.11 973 294 3.28 / 319.92 2 6
7 13 18.88 20 15.20 386 117 3.40 / 320.04 2 3
8 8 0.12 165 15.16 340 850 4.25 / 320.89 2 19
Average= 3.96
(KJ/cycle)

Cycle 79 GMT 24/12/2020 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 32 15.14 477 231 0.23 / 312.94 2 2
2 7 2006.96 32 14.98 2930 1405 1.64 / 314.34 2 3
3 13 1519.84 20 14.98 2353 705 2.34 / 315.05 2 4
4 13 1013.56 20 15.01 1722 517 2.86 / 315.56 2 4
5 13 319.60 20 15.15 793 240 3.10 / 315.80 2 3
6 8 0.12 165 15.18 335 839 3.94 / 316.64 2 16
Average= 3.96
(KJ/cycle)

Cycle 78 GMT 14/12/2020 6:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 15.14 495 240 0.24 / 308.86 2 2
2 7 2013.40 33 14.98 2937 1452 1.69 / 310.31 2 3
3 13 1525.32 20 14.98 2374 711 2.40 / 311.02 2 4
4 13 1009.68 20 15.01 1721 517 2.92 / 311.53 2 4
5 13 495.12 20 15.10 1063 321 3.24 / 311.86 2 4
6 8 0.04 165 15.18 339 849 4.09 / 312.70 2 19
Average= 3.96
(KJ/cycle)

Cycle 77 GMT 4/12/2020 8:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 32 15.15 494 239 0.24 / 304.78 2 2
2 7 2005.32 32 14.99 2929 1405 1.64 / 306.19 2 4
3 13 1664.64 20 14.97 2544 762 2.41 / 306.95 2 4
4 13 985.00 20 15.02 1715 515 2.92 / 307.46 2 5
5 13 457.52 20 15.11 1014 306 3.23 / 307.77 2 4
6 8 0.16 165 15.18 337 844 4.07 / 308.62 2 15
Average= 3.96
(KJ/cycle)

Cycle 76 GMT 24/11/2020 11: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 32 15.14 496 240 0.24 / 300.76 2 2
2 7 2002.04 32 14.98 2922 1401 1.64 / 302.16 2 4
3 13 1671.88 20 14.96 2569 769 2.41 / 302.93 2 4
4 13 1104.44 20 15.01 1849 555 2.96 / 303.49 2 4
5 13 239.28 20 15.18 688 209 3.17 / 303.70 2 4
6 8 0.12 165 15.20 338 848 4.02 / 304.54 2 15
Average= 3.96
(KJ/cycle)

Cycle 75 GMT 14/11/2020 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 32 15.14 492 238 0.24 / 296.71 2 2
2 7 2006.24 32 14.98 2936 1407 1.65 / 298.12 2 5
3 13 1534.56 20 14.98 2379 713 2.36 / 298.83 2 3
4 13 1006.48 20 15.02 1729 519 2.88 / 299.35 2 4
5 13 486.16 20 15.11 1054 319 3.20 / 299.67 2 4
6 8 0.12 165 15.18 341 854 4.05 / 300.52 2 17
Average= 3.95
(KJ/cycle)

Cycle 74 GMT 4/11/2020 15:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 32 15.15 478 232 0.23 / 292.52 2 2
2 3 1018.64 1 15.24 1801 27 0.26 / 292.55 2 3
3 7 2008.00 33 14.99 2942 1455 1.71 / 294.00 2 5
4 13 1667.40 20 14.97 2538 760 2.47 / 294.76 2 3
5 13 1114.20 20 15.00 1868 560 3.03 / 295.32 2 4
6 13 392.44 20 15.14 927 281 3.32 / 295.60 2 4
7 8 0.12 165 15.19 347 870 4.19 / 296.47 2 15
Average= 3.95
(KJ/cycle)

Cycle 73 GMT 25/10/2020 17:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 32 15.15 493 239 0.24 / 288.43 2 2
2 7 2010.36 32 15.00 2921 1402 1.64 / 289.83 2 3
3 13 1523.96 20 14.99 2390 717 2.36 / 290.55 2 3
4 13 1009.92 20 15.03 1711 514 2.87 / 291.06 2 4
5 13 322.16 20 15.17 805 244 3.12 / 291.31 2 3
6 8 0.04 165 15.19 339 850 3.97 / 292.16 2 15
7 14 0.04 25 15.17 338 128 4.09 / 292.29 3 19
Average= 3.95
(KJ/cycle)

Cycle 72 GMT 15/10/2020 20: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 32 15.15 482 234 0.23 / 284.48 2 2
2 7 2003.24 32 15.00 2945 1414 1.65 / 285.89 2 4
3 13 1535.68 20 14.98 2411 722 2.37 / 286.62 2 3
4 13 910.24 20 15.04 1624 488 2.86 / 287.10 2 4
5 13 257.20 20 15.18 726 220 3.08 / 287.33 2 3
6 8 0.12 165 15.19 346 867 3.95 / 288.19 2 18
Average= 3.95
(KJ/cycle)

Cycle 71 GMT 5/10/2020 21:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 31 15.16 491 231 0.23 / 280.44 2 2
2 3 1021.96 1 15.23 1834 28 0.26 / 280.47 2 3
3 7 2008.52 33 15.01 2927 1450 1.71 / 281.92 2 5
4 13 1524.72 20 15.00 2354 706 2.41 / 282.63 2 4
5 13 1011.76 20 15.03 1746 525 2.94 / 283.15 2 5
6 13 307.56 20 15.17 806 245 3.18 / 283.40 2 3
7 8 0.24 165 15.20 339 850 4.03 / 284.25 2 16
Average= 3.95
(KJ/cycle)

Cycle 70 GMT 25/ 9/2020 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 15.16 472 222 0.22 / 276.31 2 2
2 7 2005.60 32 15.00 2927 1405 1.63 / 277.71 2 3
3 13 1691.60 20 14.98 2563 768 2.39 / 278.48 2 4
4 13 1136.16 20 15.02 1896 570 2.96 / 279.05 2 4
5 13 408.52 20 15.16 929 282 3.25 / 279.33 2 4
6 8 0.12 165 15.20 352 883 4.13 / 280.21 2 14
Average= 3.95
(KJ/cycle)

Cycle 69 GMT 16/ 9/2020 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 32 15.16 485 235 0.24 / 272.05 2 2
2 3 966.48 -1 15.52 0 0 0.00 / 272.05 2 2
3 7 2004.60 32 15.01 2923 1404 1.64 / 273.46 2 4
4 13 1672.00 20 14.99 2543 762 2.40 / 274.22 2 4
5 13 989.64 20 15.05 1704 513 2.91 / 274.73 2 4
6 13 323.32 20 15.17 825 250 3.16 / 274.98 2 4
7 13 69.36 20 15.23 450 137 3.30 / 275.12 2 3
8 8 -0.36 165 15.20 334 838 4.14 / 275.96 2 12
9 14 -0.36 25 15.18 338 128 4.27 / 276.08 3 19
Average= 3.94
(KJ/cycle)

Cycle 68 GMT 6/ 9/2020 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 32 15.17 484 235 0.23 / 268.18 2 2
2 7 2005.64 32 15.00 2910 1397 1.63 / 269.57 2 3
3 13 1524.72 20 14.99 2389 716 2.35 / 270.29 2 3
4 13 868.24 20 15.07 1561 470 2.82 / 270.76 2 4
5 13 214.44 20 15.20 661 201 3.02 / 270.96 2 3
6 8 0.04 165 15.21 340 853 3.87 / 271.82 2 15
Average= 3.94
(KJ/cycle)

Cycle 67 GMT 27/ 8/2020 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 33 15.17 477 239 0.24 / 264.20 2 2
2 7 2009.40 32 15.01 2924 1404 1.64 / 265.60 2 3
3 13 1522.80 20 15.00 2394 718 2.36 / 266.32 2 3
4 13 1024.76 20 15.04 1760 529 2.89 / 266.85 2 4
5 13 342.72 20 15.18 831 252 3.14 / 267.10 2 3
6 8 -0.12 165 15.21 334 838 3.98 / 267.94 2 12
Average= 3.94
(KJ/cycle)

Cycle 66 GMT 17/ 8/2020 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 33 15.17 485 243 0.24 / 260.18 2 2
2 7 2008.64 32 15.01 2928 1406 1.65 / 261.58 2 3
3 13 1545.52 20 15.00 2394 718 2.37 / 262.30 2 3
4 13 1042.40 20 15.04 1772 533 2.90 / 262.83 2 3
5 13 368.36 20 15.17 882 268 3.17 / 263.10 2 3
6 8 0.20 165 15.21 343 861 4.03 / 263.96 2 15
Average= 3.94
(KJ/cycle)

Cycle 65 GMT 7/ 8/2020 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 33 15.17 488 244 0.24 / 256.01 2 2
2 7 2007.64 32 15.02 2930 1408 1.65 / 257.42 2 2
3 13 1686.48 20 14.99 2577 773 2.43 / 258.19 2 3
4 13 1150.40 20 15.02 1921 577 3.00 / 258.77 2 4
5 13 435.16 20 15.16 980 297 3.30 / 259.06 2 3
6 8 0.16 165 15.21 346 868 4.17 / 259.93 2 15
Average= 3.94
(KJ/cycle)

Cycle 64 GMT 28/ 7/2020 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 33 15.18 474 237 0.24 / 251.99 2 2
2 7 2003.04 32 15.03 2914 1402 1.64 / 253.39 2 4
3 13 1672.48 20 15.01 2525 758 2.40 / 254.14 2 3
4 13 997.72 20 15.06 1703 513 2.91 / 254.66 2 3
5 13 311.64 20 15.19 794 241 3.15 / 254.90 2 3
6 8 0.40 165 15.22 345 866 4.02 / 255.77 2 16
Average= 3.93
(KJ/cycle)

Cycle 63 GMT 18/ 7/2020 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 33 15.18 470 235 0.24 / 247.91 2 2
2 7 2006.36 32 15.03 2909 1399 1.63 / 249.31 2 3
3 13 1523.60 20 15.02 2357 708 2.34 / 250.02 2 4
4 13 1025.04 20 15.05 1757 529 2.87 / 250.55 2 4
5 13 350.52 20 15.19 823 250 3.12 / 250.80 2 3
6 8 0.12 165 15.22 328 824 3.95 / 251.62 2 15
7 14 0.12 25 15.20 330 125 4.07 / 251.75 3 13
Average= 3.93
(KJ/cycle)

Cycle 62 GMT 8/ 7/2020 16:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 33 15.19 457 229 0.23 / 243.97 2 2
2 7 2006.80 32 15.04 2903 1397 1.63 / 245.36 2 5
3 13 1528.64 20 15.02 2366 711 2.34 / 246.07 2 3
4 13 1027.88 20 15.06 1730 521 2.86 / 246.59 2 4
5 13 348.60 20 15.19 818 249 3.11 / 246.84 2 3
6 8 -0.08 165 15.23 332 834 3.94 / 247.68 2 13
Average= 3.93
(KJ/cycle)

Cycle 61 GMT 28/ 6/2020 18:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 33 15.20 467 234 0.23 / 239.94 2 2
2 7 2003.96 32 15.04 2906 1399 1.63 / 241.33 2 4
3 13 1659.28 20 15.02 2518 756 2.39 / 242.09 2 3
4 13 1123.00 20 15.05 1849 557 2.95 / 242.65 2 3
5 13 418.12 20 15.19 912 277 3.22 / 242.92 2 3
6 8 0.16 165 15.24 323 812 4.04 / 243.74 2 12
Average= 3.93
(KJ/cycle)

Cycle 60 GMT 18/ 6/2020 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 32 15.20 486 236 0.24 / 235.85 2 2
2 7 2009.68 33 15.03 2913 1445 1.68 / 237.29 2 3
3 13 1684.96 20 15.01 2547 765 2.45 / 238.06 2 3
4 13 992.64 20 15.07 1716 517 2.96 / 238.57 2 4
5 13 184.92 20 15.24 602 183 3.15 / 238.76 2 3
6 8 0.08 165 15.24 326 820 3.97 / 239.58 2 16
7 14 0.08 25 15.22 326 124 4.09 / 239.70 4 13
Average= 3.93
(KJ/cycle)

Cycle 59 GMT 8/ 6/2020 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 32 15.19 496 241 0.24 / 231.77 2 2
2 7 2003.92 32 15.04 2937 1414 1.65 / 233.18 2 3
3 13 1683.68 20 15.01 2583 775 2.43 / 233.96 2 3
4 13 1000.60 20 15.07 1731 522 2.95 / 234.48 2 3
5 13 328.04 20 15.21 825 251 3.20 / 234.73 2 3
6 8 -0.08 165 15.24 350 880 4.08 / 235.61 2 11
Average= 3.93
(KJ/cycle)

Cycle 58 GMT 30/ 5/2020 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 32 15.21 459 223 0.22 / 227.66 2 2
2 7 2010.68 32 15.04 2920 1405 1.63 / 229.07 2 3
3 13 1540.52 20 15.03 2381 716 2.34 / 229.78 2 3
4 13 1032.00 20 15.07 1742 525 2.87 / 230.31 2 4
5 13 347.84 20 15.21 826 251 3.12 / 230.56 2 3
6 13 31.68 20 15.27 396 121 3.24 / 230.68 2 3
7 8 0.16 165 15.24 338 850 4.09 / 231.53 2 17
Average= 3.92
(KJ/cycle)

Cycle 57 GMT 20/ 5/2020 3:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 32 15.21 475 231 0.23 / 223.67 2 2
2 7 2011.84 32 15.05 2919 1406 1.64 / 225.08 2 3
3 13 1696.12 20 15.01 2596 779 2.42 / 225.86 2 3
4 13 998.44 20 15.08 1720 519 2.94 / 226.38 2 4
5 13 325.44 20 15.22 800 244 3.18 / 226.62 2 3
6 8 0.32 165 15.25 325 818 4.00 / 227.44 2 13
Average= 3.92
(KJ/cycle)

Cycle 56 GMT 10/ 5/2020 5:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 32 15.22 469 228 0.23 / 219.70 2 2
2 7 2006.56 33 15.04 2917 1448 1.68 / 221.14 2 3
3 13 1510.52 20 15.04 2335 702 2.38 / 221.85 2 3
4 13 1013.32 20 15.09 1716 518 2.90 / 222.36 2 4
5 13 307.24 20 15.22 797 243 3.14 / 222.61 2 3
6 8 0.20 165 15.25 331 833 3.97 / 223.44 2 12
Average= 3.92
(KJ/cycle)

Cycle 55 GMT 30/ 4/2020 7:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 32 15.22 464 226 0.23 / 215.77 2 2
2 7 2002.84 32 15.04 2902 1397 1.62 / 217.17 2 4
3 13 1520.84 20 15.04 2352 707 2.33 / 217.87 2 3
4 13 1008.12 20 15.08 1739 524 2.85 / 218.40 2 4
5 13 309.32 20 15.23 783 239 3.09 / 218.64 2 3
6 8 0.36 165 15.26 330 831 3.92 / 219.47 2 10
Average= 3.92
(KJ/cycle)

Cycle 54 GMT 20/ 4/2020 10: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 32 15.22 455 222 0.22 / 211.59 2 2
2 7 2005.92 32 15.05 2928 1410 1.63 / 213.00 2 3
3 13 1684.04 20 15.02 2576 774 2.41 / 213.77 2 3
4 13 1138.28 20 15.07 1879 566 2.97 / 214.34 2 3
5 13 411.96 20 15.21 914 278 3.25 / 214.62 2 3
6 13 38.88 20 15.29 393 120 3.37 / 214.74 2 3
7 8 -0.12 165 15.26 321 808 4.18 / 215.54 2 14
Average= 3.92
(KJ/cycle)

Cycle 53 GMT 10/ 4/2020 12:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 32 15.22 472 230 0.23 / 207.53 2 2
2 7 2006.00 32 15.05 2920 1406 1.64 / 208.94 2 4
3 13 1671.16 20 15.03 2546 765 2.40 / 209.70 2 3
4 13 966.92 20 15.10 1687 509 2.91 / 210.21 2 3
5 13 270.24 20 15.24 727 222 3.13 / 210.43 2 3
6 13 24.84 20 15.29 375 115 3.25 / 210.55 2 3
7 8 0.04 165 15.26 325 818 4.07 / 211.37 2 15
Average= 3.91
(KJ/cycle)

Cycle 52 GMT 31/ 3/2020 14:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 32 15.22 480 234 0.23 / 203.48 2 2
2 7 2005.36 32 15.05 2927 1410 1.64 / 204.89 2 3
3 13 1516.56 20 15.05 2346 706 2.35 / 205.59 2 3
4 13 994.24 20 15.11 1694 512 2.86 / 206.11 2 5
5 13 293.12 20 15.24 780 238 3.10 / 206.34 2 3
6 8 0.20 165 15.27 330 831 3.93 / 207.18 2 10
7 14 0.20 25 15.25 328 125 4.06 / 207.30 4 11
Average= 3.91
(KJ/cycle)

Cycle 51 GMT 21/ 3/2020 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 32 15.22 478 233 0.23 / 199.41 2 2
2 7 2003.48 32 15.06 2907 1401 1.63 / 200.81 2 3
3 13 1517.60 20 15.06 2346 707 2.34 / 201.52 2 3
4 13 1015.36 20 15.11 1725 521 2.86 / 202.04 2 4
5 13 318.20 20 15.24 792 241 3.10 / 202.28 2 3
6 13 28.72 20 15.29 392 120 3.22 / 202.40 2 3
7 8 0.08 165 15.26 336 846 4.07 / 203.24 2 14
Average= 3.91
(KJ/cycle)

Cycle 50 GMT 11/ 3/2020 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 32 15.23 465 227 0.23 / 195.34 2 2
2 7 2004.20 32 15.06 2922 1408 1.63 / 196.75 2 3
3 13 1524.48 20 15.06 2357 710 2.34 / 197.46 2 3
4 13 1022.92 20 15.10 1756 530 2.88 / 197.99 2 3
5 13 324.48 20 15.24 809 247 3.12 / 198.23 2 3
6 13 29.32 20 15.30 384 118 3.24 / 198.35 2 3
7 8 0.04 165 15.27 327 824 4.06 / 199.18 2 13
Average= 3.91
(KJ/cycle)

Cycle 49 GMT 1/ 3/2020 20:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 32 15.22 477 232 0.23 / 191.28 2 2
2 7 2008.32 33 15.05 2936 1458 1.69 / 192.74 2 4
3 13 1524.32 20 15.05 2377 715 2.41 / 193.45 2 3
4 13 1002.72 20 15.11 1710 517 2.92 / 193.97 2 5
5 13 167.96 20 15.28 597 182 3.11 / 194.15 2 3
6 13 34.52 20 15.30 401 123 3.23 / 194.27 2 3
7 8 0.16 165 15.27 333 839 4.07 / 195.11 2 15
Average= 3.90
(KJ/cycle)

Cycle 48 GMT 20/ 2/2020 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 32 15.23 486 237 0.24 / 187.15 2 2
2 7 2003.48 32 15.06 2925 1410 1.65 / 188.56 2 2
3 13 1526.92 20 15.06 2387 719 2.37 / 189.28 2 3
4 13 1025.96 20 15.10 1760 532 2.90 / 189.81 2 3
5 13 338.24 20 15.24 850 259 3.16 / 190.07 2 3
6 13 27.16 20 15.30 397 121 3.28 / 190.19 2 3
7 8 0.08 165 15.27 338 852 4.13 / 191.05 2 12
Average= 3.90
(KJ/cycle)

Cycle 47 GMT 11/ 2/2020 0:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 32 15.24 479 234 0.23 / 183.09 2 2
2 7 2006.16 32 15.07 2906 1401 1.63 / 184.49 2 3
3 13 1519.04 20 15.06 2381 717 2.35 / 185.21 2 4
4 13 1017.12 20 15.11 1752 529 2.88 / 185.74 2 3
5 13 477.80 20 15.21 1042 317 3.20 / 186.05 2 3
6 8 -0.04 165 15.28 342 862 4.06 / 186.92 2 12
Average= 3.89
(KJ/cycle)

Cycle 46 GMT 1/ 2/2020 3:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 32 15.25 471 230 0.23 / 179.15 2 2
2 7 2004.92 32 15.07 2919 1408 1.64 / 180.56 2 3
3 13 1518.20 20 15.08 2344 707 2.34 / 181.27 2 3
4 13 1010.24 20 15.12 1733 524 2.87 / 181.79 2 3
5 13 311.84 20 15.26 785 240 3.11 / 182.03 2 3
6 8 0.16 165 15.29 326 822 3.93 / 182.86 2 11
Average= 3.89
(KJ/cycle)

Cycle 45 GMT 22/ 1/2020 5:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 32 15.26 465 227 0.23 / 175.08 2 2
2 7 2006.68 32 15.07 2913 1405 1.63 / 176.48 2 3
3 13 1667.08 20 15.06 2521 759 2.39 / 177.24 2 3
4 13 994.60 20 15.13 1692 512 2.90 / 177.75 2 4
5 13 318.96 20 15.26 791 241 3.14 / 178.00 2 3
6 13 26.92 20 15.31 382 117 3.26 / 178.11 2 3
7 8 0.12 165 15.29 322 812 4.07 / 178.93 2 13
Average= 3.89
(KJ/cycle)

Cycle 44 GMT 12/ 1/2020 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 32 15.26 468 229 0.23 / 171.17 2 2
2 7 2007.00 32 15.08 2910 1404 1.63 / 172.57 2 4
3 13 1520.20 20 15.07 2354 709 2.34 / 173.28 2 3
4 13 1017.80 20 15.12 1734 524 2.87 / 173.80 2 3
5 13 317.08 20 15.27 781 239 3.11 / 174.04 2 3
6 8 0.00 165 15.30 320 808 3.91 / 174.85 2 9
Average= 3.89
(KJ/cycle)

Cycle 43 GMT 2/ 1/2020 9:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 32 15.26 473 231 0.23 / 167.30 2 2
2 7 2005.76 32 15.08 2913 1406 1.64 / 168.71 2 2
3 13 1519.12 20 15.08 2377 717 2.35 / 169.42 2 3
4 13 1006.64 20 15.13 1727 523 2.88 / 169.95 2 3
5 13 184.04 20 15.30 597 183 3.06 / 170.13 2 3
6 8 0.20 165 15.30 321 810 3.87 / 170.94 2 11
Average= 3.88
(KJ/cycle)

Cycle 42 GMT 23/12/2019 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 32 15.26 472 230 0.23 / 163.34 2 2
2 7 2005.52 32 15.08 2923 1411 1.64 / 164.75 2 2
3 13 1515.24 20 15.08 2383 719 2.36 / 165.47 2 4
4 13 1013.76 20 15.13 1734 525 2.88 / 165.99 2 3
5 13 331.28 20 15.26 813 248 3.13 / 166.24 2 3
6 8 0.20 165 15.30 328 828 3.96 / 167.07 2 10
Average= 3.89
(KJ/cycle)

Cycle 41 GMT 13/12/2019 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 32 15.25 482 235 0.24 / 159.45 2 2
2 7 2005.84 32 15.08 2911 1405 1.64 / 160.86 2 4
3 13 1512.08 20 15.08 2342 706 2.35 / 161.56 2 3
4 13 1010.48 20 15.13 1713 518 2.86 / 162.08 2 5
5 13 179.24 20 15.30 621 190 3.05 / 162.27 2 2
6 8 0.20 165 15.30 331 836 3.89 / 163.11 2 10
Average= 3.88
(KJ/cycle)

Cycle 40 GMT 3/12/2019 16: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 32 15.26 485 237 0.24 / 155.35 2 2
2 7 2004.48 32 15.08 2900 1399 1.64 / 156.75 2 4
3 13 1675.52 20 15.07 2550 769 2.40 / 157.52 2 3
4 13 1121.08 20 15.12 1856 561 2.97 / 158.08 2 3
5 13 423.32 20 15.25 946 289 3.25 / 158.37 2 3
6 8 0.08 165 15.30 337 851 4.11 / 159.22 2 11
Average= 3.88
(KJ/cycle)

Cycle 39 GMT 23/11/2019 18:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 32 15.26 489 239 0.24 / 151.33 2 2
2 7 2004.56 32 15.09 2902 1401 1.64 / 152.73 2 3
3 13 1665.00 20 15.07 2522 760 2.40 / 153.49 2 3
4 13 985.96 20 15.14 1710 518 2.92 / 154.01 2 5
5 13 321.92 20 15.28 808 247 3.16 / 154.26 2 3
6 8 0.20 165 15.30 339 856 4.02 / 155.11 2 10
Average= 3.88
(KJ/cycle)

Cycle 38 GMT 13/11/2019 20:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 32 15.27 467 228 0.23 / 147.34 2 2
2 7 2004.28 32 15.09 2903 1402 1.63 / 148.74 2 2
3 13 1520.64 20 15.09 2368 715 2.34 / 149.46 2 3
4 13 1026.60 20 15.14 1730 524 2.87 / 149.98 2 3
5 13 337.64 20 15.28 804 246 3.11 / 150.23 2 3
6 8 -0.08 165 15.30 342 863 3.98 / 151.09 2 11
Average= 3.87
(KJ/cycle)

Cycle 37 GMT 3/11/2019 22:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 32 15.26 487 238 0.24 / 143.39 2 2
2 7 2005.44 32 15.09 2920 1410 1.65 / 144.80 2 3
3 13 1531.32 20 15.10 2360 713 2.36 / 145.52 2 3
4 13 1027.04 20 15.14 1735 525 2.89 / 146.04 2 4
5 13 325.36 20 15.28 803 245 3.13 / 146.29 2 3
6 8 0.08 165 15.31 327 826 3.96 / 147.11 2 10
Average= 3.87
(KJ/cycle)

Cycle 36 GMT 25/10/2019 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 32 15.27 482 236 0.24 / 139.44 2 2
2 7 2003.76 33 15.09 2897 1443 1.68 / 140.88 2 3
3 13 1506.60 20 15.10 2326 702 2.38 / 141.59 2 3
4 13 875.96 20 15.18 1536 466 2.85 / 142.05 2 3
5 13 348.96 20 15.28 828 253 3.10 / 142.31 2 3
6 8 -0.08 165 15.31 337 851 3.95 / 143.16 2 9
Average= 3.87
(KJ/cycle)

Cycle 35 GMT 15/10/2019 2:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 32 15.27 495 242 0.24 / 135.47 2 2
2 7 2006.68 32 15.09 2910 1405 1.65 / 136.88 2 3
3 13 1508.52 20 15.10 2327 703 2.35 / 137.58 2 3
4 13 1005.64 20 15.15 1717 520 2.87 / 138.10 2 4
5 13 309.24 20 15.28 798 244 3.11 / 138.34 2 3
6 8 -0.04 165 15.31 341 861 3.98 / 139.21 2 8
Average= 3.87
(KJ/cycle)

Cycle 34 GMT 5/10/2019 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 32 15.27 492 240 0.24 / 131.49 2 2
2 7 2003.28 33 15.09 2906 1447 1.69 / 132.94 2 3
3 13 1515.64 20 15.10 2382 719 2.41 / 133.66 2 3
4 13 1003.00 20 15.15 1738 527 2.93 / 134.18 2 3
5 13 175.60 20 15.32 607 186 3.12 / 134.37 2 2
6 8 0.12 165 15.32 341 862 3.98 / 135.23 2 10
Average= 3.86
(KJ/cycle)

Cycle 33 GMT 25/ 9/2019 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 15.29 504 239 0.24 / 127.46 2 2
2 7 2005.16 32 15.09 2925 1412 1.65 / 128.87 2 3
3 13 1513.36 20 15.10 2378 718 2.37 / 129.59 2 3
4 13 1004.48 20 15.15 1744 528 2.90 / 130.11 2 4
5 13 302.56 20 15.29 794 243 3.14 / 130.36 2 3
6 8 0.28 165 15.31 353 892 4.03 / 131.25 2 12
Average= 3.86
(KJ/cycle)

Cycle 32 GMT 15/ 9/2019 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 31 15.32 473 225 0.22 / 123.80 2 2
2 7 1530.48 32 15.23 2344 1142 1.37 / 124.94 2 3
3 13 1397.04 20 15.20 2190 666 2.03 / 125.61 2 2
4 13 895.28 20 15.23 1594 486 2.52 / 126.09 2 3
5 13 211.64 20 15.35 683 210 2.73 / 126.30 2 3
6 8 0.12 165 15.35 361 914 3.64 / 127.22 2 10
Average= 3.86
(KJ/cycle)

Cycle 31 GMT 5/ 9/2019 11:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 15.29 466 221 0.22 / 120.36 2 2
2 7 1432.48 32 15.26 2229 1088 1.31 / 121.45 2 4
3 13 1316.04 20 15.22 2101 640 1.95 / 122.09 2 3
4 13 852.80 20 15.25 1523 465 2.41 / 122.55 2 3
5 13 165.08 20 15.38 576 177 2.59 / 122.73 2 2
6 8 0.16 165 15.37 333 845 3.44 / 123.57 2 10
Average= 3.86
(KJ/cycle)

Cycle 30 GMT 26/ 8/2019 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 32 15.28 491 240 0.24 / 116.26 2 2
2 7 2003.08 32 15.11 2912 1408 1.65 / 117.66 2 3
3 13 1673.68 20 15.09 2542 767 2.42 / 118.43 2 3
4 13 980.40 20 15.17 1681 510 2.93 / 118.94 2 4
5 13 293.20 20 15.31 756 231 3.16 / 119.17 2 3
6 8 -0.12 165 15.33 332 840 4.00 / 120.01 2 9
7 14 -0.12 25 15.30 331 127 4.12 / 120.14 2 15
Average= 3.88
(KJ/cycle)

Cycle 29 GMT 16/ 8/2019 16:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 32 15.27 502 245 0.25 / 112.24 2 2
2 7 2008.08 32 15.10 2926 1414 1.66 / 113.65 2 4
3 13 1516.84 20 15.11 2379 719 2.38 / 114.37 2 3
4 13 1001.04 20 15.17 1719 522 2.90 / 114.89 2 3
5 13 307.96 20 15.30 794 243 3.14 / 115.14 2 3
6 8 -0.08 165 15.32 348 880 4.02 / 116.02 2 9
Average= 3.87
(KJ/cycle)

Cycle 28 GMT 6/ 8/2019 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 32 15.29 501 245 0.25 / 108.17 2 2
2 7 2012.92 32 15.11 2931 1417 1.66 / 109.59 2 3
3 13 1533.04 20 15.12 2375 718 2.38 / 110.31 2 3
4 13 1017.52 20 15.16 1766 535 2.92 / 110.84 2 4
5 13 328.68 20 15.29 844 258 3.17 / 111.10 2 3
6 8 0.12 165 15.32 353 892 4.07 / 111.99 2 9
Average= 3.86
(KJ/cycle)

Cycle 27 GMT 27/ 7/2019 20:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 31 15.30 473 224 0.22 / 104.15 2 2
2 7 2004.72 32 15.11 2918 1411 1.64 / 105.56 2 3
3 13 1516.92 20 15.12 2372 717 2.35 / 106.28 2 2
4 13 996.36 20 15.17 1738 527 2.88 / 106.80 2 3
5 13 286.92 20 15.31 776 238 3.12 / 107.04 2 2
6 8 0.12 165 15.33 350 885 4.00 / 107.93 2 6
Average= 3.85
(KJ/cycle)

Cycle 26 GMT 17/ 7/2019 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 31 15.30 471 223 0.22 / 100.23 2 2
2 7 2003.60 32 15.12 2899 1403 1.63 / 101.64 2 4
3 13 1506.48 20 15.13 2326 704 2.33 / 102.34 2 3
4 13 990.72 20 15.18 1688 512 2.84 / 102.85 2 3
5 13 300.52 20 15.31 776 238 3.08 / 103.09 2 2
6 8 0.08 165 15.34 330 835 3.92 / 103.92 2 8
Average= 3.85
(KJ/cycle)

Cycle 25 GMT 8/ 7/2019 0:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 31 15.31 474 225 0.22 / 96.26 2 2
2 7 2010.92 33 15.12 2906 1450 1.67 / 97.71 2 3
3 13 1516.36 20 15.13 2369 717 2.39 / 98.42 2 3
4 13 985.24 20 15.18 1700 516 2.91 / 98.94 2 3
5 13 287.80 20 15.32 751 230 3.14 / 99.17 2 3
6 8 0.36 165 15.35 331 838 3.98 / 100.01 2 7
Average= 3.85
(KJ/cycle)

Cycle 24 GMT 28/ 6/2019 2:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 31 15.32 448 213 0.21 / 92.39 2 2
2 7 2004.12 32 15.13 2883 1396 1.61 / 93.79 2 4
3 13 1667.88 20 15.13 2497 756 2.36 / 94.54 2 3
4 13 962.28 20 15.20 1641 499 2.86 / 95.04 2 4
5 13 170.40 20 15.36 565 174 3.04 / 95.22 2 2
6 8 0.16 165 15.36 322 816 3.85 / 96.03 2 9
Average= 3.84
(KJ/cycle)

Cycle 23 GMT 18/ 6/2019 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 31 15.32 451 214 0.21 / 88.53 2 2
2 7 2002.92 32 15.13 2888 1398 1.61 / 89.93 2 3
3 13 1668.12 20 15.13 2504 758 2.37 / 90.69 2 3
4 13 970.92 20 15.20 1646 500 2.87 / 91.19 2 3
5 13 278.24 20 15.34 712 218 3.09 / 91.41 2 3
6 8 -0.24 165 15.36 304 770 3.86 / 92.18 2 5
Average= 3.84
(KJ/cycle)

Cycle 22 GMT 8/ 6/2019 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 31 15.32 460 218 0.22 / 84.56 2 2
2 7 2006.64 32 15.13 2896 1402 1.62 / 85.96 2 3
3 13 1515.28 20 15.15 2328 705 2.33 / 86.66 2 3
4 13 1011.68 20 15.19 1696 515 2.84 / 87.18 2 4
5 13 307.84 20 15.33 754 231 3.07 / 87.41 2 3
6 13 19.00 20 15.38 356 110 3.18 / 87.52 2 3
7 8 0.28 165 15.35 316 800 3.98 / 88.32 2 12
Average= 3.84
(KJ/cycle)

Cycle 21 GMT 29/ 5/2019 8:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 31 15.32 458 218 0.22 / 80.69 2 2
2 7 2006.28 32 15.14 2888 1399 1.62 / 82.09 2 3
3 13 1516.84 20 15.15 2328 705 2.32 / 82.79 2 3
4 13 1007.52 20 15.20 1689 513 2.84 / 83.31 2 3
5 13 298.68 20 15.34 741 227 3.06 / 83.53 2 3
6 8 0.00 165 15.36 318 806 3.87 / 84.34 2 6
Average= 3.83
(KJ/cycle)

Cycle 20 GMT 19/ 5/2019 10:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 31 15.32 455 216 0.22 / 76.81 2 2
2 7 2003.32 33 15.13 2891 1443 1.66 / 78.25 2 3
3 13 1494.84 20 15.15 2300 697 2.36 / 78.95 2 3
4 13 970.32 20 15.21 1638 498 2.85 / 79.45 2 3
5 13 268.40 20 15.34 698 214 3.07 / 79.66 2 3
6 8 0.24 165 15.36 318 806 3.87 / 80.47 2 6
Average= 3.83
(KJ/cycle)

Cycle 19 GMT 9/ 5/2019 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 31 15.33 454 216 0.22 / 72.96 2 2
2 7 2004.12 32 15.14 2890 1400 1.62 / 74.36 2 3
3 13 1503.16 20 15.15 2310 700 2.32 / 75.06 2 3
4 13 981.28 20 15.21 1664 506 2.82 / 75.57 2 3
5 13 270.52 20 15.35 701 215 3.04 / 75.78 2 3
6 8 -0.04 165 15.36 320 811 3.85 / 76.59 2 8
Average= 3.83
(KJ/cycle)

Cycle 18 GMT 29/ 4/2019 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 31 15.34 443 211 0.21 / 69.10 2 2
2 7 2006.00 32 15.15 2910 1411 1.62 / 70.51 2 3
3 13 1685.40 20 15.13 2537 768 2.39 / 71.28 2 3
4 13 993.92 20 15.21 1682 512 2.90 / 71.79 2 3
5 13 171.04 20 15.37 565 174 3.07 / 71.97 2 2
6 8 -0.08 165 15.37 308 781 3.86 / 72.75 2 5
Average= 3.83
(KJ/cycle)

Cycle 17 GMT 19/ 4/2019 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 31 15.34 442 210 0.21 / 65.25 2 2
2 3 1015.68 1 15.40 1749 27 0.24 / 65.28 2 2
3 7 2004.56 32 15.16 2891 1402 1.64 / 66.68 2 3
4 13 1519.52 20 15.16 2324 705 2.34 / 67.38 2 3
5 13 1004.56 20 15.21 1682 512 2.86 / 67.90 2 3
6 13 308.84 20 15.35 748 230 3.09 / 68.12 2 2
7 8 0.12 165 15.38 302 766 3.85 / 68.89 2 6
Average= 3.83
(KJ/cycle)

Cycle 16 GMT 9/ 4/2019 18:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 31 15.35 448 213 0.21 / 61.42 2 2
2 7 2003.68 32 15.16 2895 1404 1.62 / 62.82 2 3
3 13 1511.00 20 15.17 2319 704 2.32 / 63.53 2 2
4 13 998.76 20 15.22 1676 510 2.83 / 64.04 2 4
5 13 297.64 20 15.35 731 224 3.06 / 64.26 2 2
6 8 0.12 165 15.38 306 777 3.83 / 65.04 2 6
Average= 3.83
(KJ/cycle)

Cycle 15 GMT 30/ 3/2019 20:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 15.35 445 212 0.21 / 57.54 2 2
2 7 2013.56 32 15.16 2898 1406 1.62 / 58.94 2 3
3 13 1633.68 20 15.16 2477 751 2.37 / 59.69 2 3
4 13 1077.72 20 15.21 1780 541 2.91 / 60.23 2 4
5 13 218.60 20 15.38 619 190 3.10 / 60.42 2 2
6 8 0.24 165 15.39 308 782 3.88 / 61.21 2 6
Average= 3.83
(KJ/cycle)

Cycle 14 GMT 20/ 3/2019 22:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 31 15.35 446 212 0.21 / 53.69 2 2
2 7 2003.04 32 15.16 2895 1404 1.62 / 55.09 2 3
3 13 1511.16 20 15.18 2323 705 2.32 / 55.80 2 2
4 13 996.80 20 15.23 1678 511 2.83 / 56.31 2 4
5 13 286.68 20 15.36 727 223 3.06 / 56.53 2 2
6 8 0.16 165 15.39 312 792 3.85 / 57.32 2 8
Average= 3.82
(KJ/cycle)

Cycle 13 GMT 11/ 3/2019 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 31 15.35 445 212 0.21 / 49.94 2 2
2 7 2002.32 33 15.16 2895 1448 1.66 / 51.39 2 4
3 13 1499.52 19 15.17 2303 664 2.32 / 52.06 2 3
4 13 981.20 19 15.23 1650 477 2.80 / 52.53 2 4
5 13 173.20 19 15.39 561 164 2.97 / 52.70 2 2
6 8 0.08 165 15.39 306 777 3.74 / 53.48 2 6
Average= 3.82
(KJ/cycle)

Cycle 12 GMT 1/ 3/2019 2:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 31 15.36 434 207 0.21 / 46.10 2 2
2 7 2002.56 32 15.16 2876 1395 1.60 / 47.50 2 2
3 13 1511.56 19 15.18 2316 668 2.27 / 48.17 2 3
4 13 997.76 19 15.23 1671 484 2.75 / 48.65 2 3
5 13 294.88 19 15.36 728 212 2.97 / 48.86 2 2
6 13 19.16 19 15.41 342 100 3.07 / 48.96 2 2
7 8 0.20 165 15.38 304 771 3.84 / 49.73 2 8
Average= 3.83
(KJ/cycle)

Cycle 11 GMT 19/ 2/2019 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 31 15.36 443 211 0.21 / 42.28 2 2
2 7 2002.16 37 15.15 2877 1613 1.82 / 43.89 2 4
3 13 1337.52 19 15.20 2099 606 2.43 / 44.50 2 3
4 13 990.12 19 15.23 1664 482 2.91 / 44.98 2 4
5 13 137.08 19 15.40 512 150 3.06 / 45.13 2 2
6 8 0.08 165 15.39 302 767 3.83 / 45.90 2 5
Average= 3.82
(KJ/cycle)

Cycle 10 GMT 9/ 2/2019 7: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 31 15.36 437 208 0.21 / 38.51 2 2
2 7 2002.72 36 15.15 2884 1573 1.78 / 40.09 2 2
3 13 1335.28 19 15.20 2093 604 2.39 / 40.69 2 3
4 13 844.76 19 15.26 1479 429 2.81 / 41.12 2 3
5 13 159.84 19 15.39 547 160 2.97 / 41.28 2 2
6 8 0.24 165 15.39 310 787 3.76 / 42.07 2 8
Average= 3.82
(KJ/cycle)

Cycle 9 GMT 30/ 1/2019 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 30 15.36 451 208 0.21 / 34.77 2 2
2 7 2001.88 36 15.15 2875 1568 1.78 / 36.34 2 2
3 13 1330.04 19 15.21 2089 604 2.38 / 36.94 2 3
4 13 839.60 19 15.26 1470 426 2.81 / 37.37 2 3
5 13 150.72 19 15.40 532 156 2.96 / 37.52 2 2
6 8 -0.08 165 15.40 309 785 3.75 / 38.31 2 6
Average= 3.83
(KJ/cycle)

Cycle 8 GMT 20/ 1/2019 11: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 30 15.36 435 200 0.20 / 30.82 2 2
2 7 2007.36 36 15.15 2884 1573 1.77 / 32.39 2 2
3 13 1476.72 19 15.19 2273 656 2.43 / 33.05 2 3
4 13 938.08 19 15.25 1601 464 2.89 / 33.51 2 3
5 13 116.00 19 15.41 493 144 3.04 / 33.66 2 2
6 8 -0.04 165 15.40 309 785 3.82 / 34.44 2 5
7 14 -0.04 25 15.38 308 118 3.94 / 34.56 2 9
Average= 3.84
(KJ/cycle)

Cycle 7 GMT 10/ 1/2019 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 15.37 435 201 0.20 / 26.98 2 2
2 3 1027.32 1 15.41 1781 27 0.23 / 27.01 2 2
3 7 2006.44 38 15.15 2884 1660 1.89 / 28.67 2 2
4 13 1476.48 18 15.20 2270 621 2.51 / 29.29 2 2
5 13 809.04 18 15.28 1433 394 2.90 / 29.68 2 3
6 13 138.12 18 15.40 521 144 3.05 / 29.83 2 2
7 8 0.04 165 15.40 311 790 3.84 / 30.62 2 8
Average= 3.83
(KJ/cycle)

Cycle 6 GMT 31/12/2018 14:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 30 15.42 435 201 0.20 / 23.21 2 2
2 3 1017.44 1 15.42 1756 27 0.23 / 23.24 2 2
3 7 2006.84 38 15.15 2883 1660 1.89 / 24.90 2 2
4 13 1313.88 18 15.23 2068 567 2.45 / 25.46 2 2
5 13 829.40 18 15.28 1450 399 2.85 / 25.86 2 3
6 13 151.16 18 15.41 524 145 3.00 / 26.01 2 2
7 8 0.04 165 15.40 304 772 3.77 / 26.78 2 6
Average= 3.83
(KJ/cycle)

Cycle 5 GMT 21/12/2018 16:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 31 15.32 427 203 0.20 / 20.08 2 2
2 3 971.52 -1 15.65 0 0 0.00 / 20.08 2 2
3 3 1028.12 1 15.43 1765 27 0.23 / 20.11 2 2
4 7 1257.20 38 15.37 1957 1143 1.37 / 21.25 2 2
5 13 1135.28 18 15.36 1822 504 1.88 / 21.76 2 2
6 13 800.40 18 15.38 1399 387 2.26 / 22.15 2 3
7 13 25.96 18 15.50 349 97 2.36 / 22.24 2 2
8 8 0.00 165 15.47 300 766 3.13 / 23.01 2 8
Average= 3.83
(KJ/cycle)

Cycle 4 GMT 11/12/2018 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 30 15.31 454 209 0.21 / 14.42 2 2
2 7 1525.68 138 15.07 2249 4677 4.89 / 19.10 2 3
3 8 0.04 165 15.35 308 780 5.67 / 19.88 2 10
Average= 3.98
(KJ/cycle)

Cycle 3 GMT 10/12/2018 18:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 15.36 435 194 0.19 / 8.75 2 2
2 3 1019.40 1 15.41 1759 27 0.22 / 8.77 2 2
3 7 1521.28 138 15.07 2243 4665 4.89 / 13.44 2 3
4 8 -0.08 165 15.34 307 777 5.66 / 14.22 2 10
Average= 3.55
(KJ/cycle)

Cycle 2 GMT 9/12/2018 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 29 15.39 435 194 0.19 / 4.90 2 2
2 7 1460.32 74 15.18 2191 2461 2.66 / 7.36 2 2
3 13 57.80 18 15.45 382 106 2.76 / 7.47 2 2
4 8 0.12 240 15.41 294 1087 3.85 / 8.55 2 11
Average= 2.85
(KJ/cycle)

Cycle 1 GMT 8/12/2018 19:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 29 15.59 394 178 0.18 / 1.72 2 2
2 3 1017.88 1 15.46 1755 27 0.21 / 1.75 2 2
3 7 999.72 74 15.32 1612 1827 2.03 / 3.58 2 3
4 8 -0.04 240 15.44 304 1127 3.16 / 4.70 2 15
Average= 2.35
(KJ/cycle)

Cycle 0 GMT 8/12/2018 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 28 15.72 404 178 0.18 / 0.18 2 2
2 7 130.68 75 15.69 408 480 0.66 / 0.66 2 2
3 8 0.24 240 15.66 236 887 1.54 / 1.54 2 9
Average= 1.54
(KJ/cycle)