SIO Argo Site:
Pump Diagnostics Page   



Serial= 8717 WMO= 5905774

Return

←PreviousNext→

Cycle 223 GMT 6/11/2024 23:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.84 31 14.81 519 238 0.24 / 878.38 2 3
2 12 1310.04 3 15.04 2055 93 0.33 / 878.47 2 3
3 7 2007.48 34 14.67 2776 1385 1.72 / 879.85 2 4
4 13 1531.12 20 14.66 2260 663 2.38 / 880.52 2 5
5 13 1021.44 20 14.68 1661 488 2.87 / 881.00 2 6
6 13 329.20 20 14.80 773 229 3.09 / 881.23 2 5
7 8 0.20 165 14.84 310 759 3.85 / 881.99 2 19
Average= 3.94
(KJ/cycle)

Cycle 222 GMT 28/10/2024 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.64 31 14.82 528 243 0.24 / 874.42 2 3
2 12 1332.12 3 15.03 2102 95 0.34 / 874.52 2 3
3 7 2002.84 34 14.68 2787 1391 1.73 / 875.91 2 4
4 13 1500.04 20 14.68 2236 656 2.38 / 876.56 2 5
5 13 987.20 20 14.69 1624 477 2.86 / 877.04 2 6
6 13 307.04 20 14.81 742 220 3.08 / 877.26 2 5
7 13 27.32 20 14.87 361 107 3.19 / 877.37 2 4
8 8 0.12 165 14.84 315 771 3.96 / 878.14 2 17
Average= 3.94
(KJ/cycle)

Cycle 221 GMT 18/10/2024 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.36 31 14.81 529 243 0.24 / 870.45 2 3
2 12 1321.96 3 15.02 2067 93 0.34 / 870.54 2 3
3 7 2004.92 34 14.69 2775 1386 1.72 / 871.93 2 4
4 13 1528.88 20 14.68 2241 658 2.38 / 872.58 2 5
5 13 1177.64 20 14.66 1838 539 2.92 / 873.12 2 5
6 13 451.12 20 14.78 932 275 3.19 / 873.40 2 6
7 8 0.04 165 14.85 318 779 3.97 / 874.18 2 15
Average= 3.94
(KJ/cycle)

Cycle 220 GMT 8/10/2024 5: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.60 31 14.82 507 233 0.23 / 866.60 2 3
2 12 1326.56 3 15.01 2115 95 0.33 / 866.69 2 3
3 7 2002.88 35 14.67 2777 1426 1.75 / 868.12 2 4
4 13 1372.84 20 14.69 2080 611 2.37 / 868.73 2 5
5 13 1039.20 20 14.68 1681 494 2.86 / 869.22 2 6
6 13 311.56 20 14.81 746 221 3.08 / 869.44 2 5
7 8 0.08 165 14.85 311 762 3.84 / 870.20 2 14
Average= 3.94
(KJ/cycle)

Cycle 219 GMT 28/ 9/2024 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.92 31 14.81 548 252 0.25 / 862.73 2 3
2 12 1336.56 3 15.02 2130 96 0.35 / 862.83 2 3
3 7 2002.88 34 14.68 2790 1393 1.74 / 864.22 2 4
4 13 1510.96 20 14.68 2245 659 2.40 / 864.88 2 5
5 13 1005.44 20 14.69 1639 482 2.88 / 865.36 2 6
6 13 328.88 20 14.81 770 228 3.11 / 865.59 2 5
7 8 0.04 165 14.85 315 772 3.88 / 866.36 2 15
Average= 3.94
(KJ/cycle)

Cycle 218 GMT 18/ 9/2024 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.32 31 14.82 521 239 0.24 / 858.76 2 3
2 3 1018.44 1 14.98 1692 25 0.26 / 858.79 2 3
3 12 1337.00 3 15.02 2130 96 0.36 / 858.88 2 3
4 7 2003.36 34 14.68 2792 1394 1.75 / 860.27 2 4
5 13 1513.44 20 14.67 2249 660 2.41 / 860.93 2 5
6 13 1008.32 20 14.69 1653 486 2.90 / 861.42 2 6
7 13 481.32 20 14.77 975 288 3.19 / 861.71 2 5
8 8 0.16 165 14.85 316 774 3.96 / 862.48 2 15
Average= 3.94
(KJ/cycle)

Cycle 217 GMT 8/ 9/2024 10: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.52 31 14.81 525 241 0.24 / 854.93 2 3
2 12 1322.68 3 15.02 2075 93 0.33 / 855.02 2 3
3 7 2001.40 34 14.69 2777 1387 1.72 / 856.41 2 4
4 13 1504.48 20 14.69 2224 653 2.37 / 857.06 2 5
5 13 1000.68 20 14.70 1635 481 2.86 / 857.55 2 6
6 13 301.60 20 14.81 735 218 3.07 / 857.76 2 5
7 8 0.00 165 14.86 309 758 3.83 / 858.52 2 13
Average= 3.94
(KJ/cycle)

Cycle 216 GMT 29/ 8/2024 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.40 31 14.81 524 241 0.24 / 850.85 2 3
2 12 1314.52 3 15.03 2067 93 0.33 / 850.94 2 3
3 7 2005.76 34 14.68 2780 1388 1.72 / 852.33 2 4
4 13 1504.60 20 14.69 2232 656 2.38 / 852.98 2 5
5 13 995.20 20 14.69 1629 479 2.86 / 853.46 2 6
6 13 470.56 20 14.78 958 283 3.14 / 853.75 2 5
7 8 0.20 165 14.85 318 779 3.92 / 854.52 2 16
8 14 0.20 35 14.83 318 165 4.08 / 854.69 4 21
Average= 3.94
(KJ/cycle)

Cycle 215 GMT 19/ 8/2024 13:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.72 31 14.81 532 244 0.24 / 846.99 2 3
2 12 1310.56 3 15.03 2092 94 0.34 / 847.08 2 3
3 7 2003.80 34 14.68 2778 1387 1.73 / 848.47 2 4
4 13 1505.80 20 14.69 2231 655 2.38 / 849.13 2 5
5 13 1002.72 20 14.70 1637 481 2.86 / 849.61 2 6
6 13 309.24 20 14.82 744 221 3.08 / 849.83 2 5
7 8 0.00 165 14.85 318 779 3.86 / 850.61 2 14
Average= 3.94
(KJ/cycle)

Cycle 214 GMT 9/ 8/2024 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.40 31 14.82 537 247 0.25 / 842.98 2 3
2 12 1315.52 3 15.03 2075 94 0.34 / 843.07 2 3
3 7 2002.08 34 14.69 2776 1387 1.73 / 844.46 2 4
4 13 1491.48 20 14.69 2213 650 2.38 / 845.11 2 5
5 13 986.84 20 14.70 1618 476 2.85 / 845.58 2 6
6 13 458.44 20 14.78 947 280 3.13 / 845.86 2 5
7 13 23.08 20 14.88 362 108 3.24 / 845.97 2 5
8 8 0.08 165 14.84 317 776 4.02 / 846.74 2 16
Average= 3.94
(KJ/cycle)

Cycle 213 GMT 30/ 7/2024 16:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.68 31 14.82 533 245 0.24 / 839.09 2 3
2 12 1307.92 3 15.03 2067 93 0.34 / 839.19 2 3
3 7 2003.20 34 14.69 2786 1391 1.73 / 840.58 2 4
4 13 1511.24 20 14.68 2256 662 2.39 / 841.24 2 5
5 13 997.80 20 14.69 1639 482 2.87 / 841.72 2 6
6 13 319.84 20 14.81 760 225 3.10 / 841.95 2 5
7 8 0.16 165 14.85 319 782 3.88 / 842.73 2 16
Average= 3.94
(KJ/cycle)

Cycle 212 GMT 20/ 7/2024 18:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.64 31 14.81 535 246 0.25 / 835.21 2 3
2 12 1329.00 3 15.01 2112 95 0.34 / 835.30 2 3
3 7 2003.16 34 14.69 2784 1390 1.73 / 836.69 2 4
4 13 1506.04 20 14.68 2232 655 2.39 / 837.35 2 5
5 13 1003.28 20 14.70 1635 481 2.87 / 837.83 2 5
6 13 314.76 20 14.82 751 223 3.09 / 838.05 2 5
7 8 -0.04 165 14.85 325 796 3.89 / 838.85 2 14
Average= 3.94
(KJ/cycle)

Cycle 211 GMT 10/ 7/2024 19:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.64 31 14.82 534 245 0.25 / 831.32 2 3
2 12 1338.20 3 15.01 2106 95 0.34 / 831.42 2 3
3 7 2003.16 35 14.67 2782 1428 1.77 / 832.85 2 4
4 13 1494.36 20 14.69 2220 652 2.42 / 833.50 2 4
5 13 972.76 20 14.71 1605 472 2.89 / 833.97 2 6
6 13 286.00 20 14.83 709 210 3.10 / 834.18 2 5
7 8 0.08 165 14.85 319 782 3.88 / 834.96 2 17
Average= 3.94
(KJ/cycle)

Cycle 210 GMT 30/ 6/2024 21:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.12 31 14.82 530 243 0.24 / 827.45 2 3
2 12 1329.88 3 15.03 2096 95 0.34 / 827.55 2 3
3 7 2004.48 34 14.69 2795 1396 1.73 / 828.95 2 4
4 13 1394.32 20 14.69 2104 618 2.35 / 829.56 2 5
5 13 1059.64 20 14.68 1705 501 2.85 / 830.06 2 6
6 13 356.88 20 14.80 806 239 3.09 / 830.30 2 5
7 8 0.24 165 14.85 316 774 3.87 / 831.08 2 14
Average= 3.94
(KJ/cycle)

Cycle 209 GMT 20/ 6/2024 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.04 31 14.83 517 238 0.24 / 823.59 2 3
2 12 1316.40 3 15.03 2093 94 0.33 / 823.69 2 3
3 7 2003.24 34 14.69 2781 1389 1.72 / 825.08 2 4
4 13 1500.64 20 14.69 2225 654 2.37 / 825.73 2 5
5 13 1008.68 20 14.70 1638 482 2.86 / 826.21 2 6
6 13 317.60 20 14.82 748 222 3.08 / 826.43 2 5
7 8 0.16 165 14.86 317 777 3.86 / 827.21 2 12
Average= 3.94
(KJ/cycle)

Cycle 208 GMT 11/ 6/2024 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.36 31 14.81 524 241 0.24 / 819.71 2 3
2 12 1310.48 3 15.02 2089 94 0.33 / 819.80 2 3
3 7 2003.40 34 14.69 2780 1388 1.72 / 821.19 2 4
4 13 1509.76 20 14.68 2228 654 2.38 / 821.84 2 5
5 13 1003.96 20 14.70 1642 483 2.86 / 822.33 2 6
6 13 319.72 20 14.81 767 227 3.09 / 822.55 2 5
7 8 0.12 165 14.85 328 804 3.89 / 823.36 2 12
Average= 3.94
(KJ/cycle)

Cycle 207 GMT 1/ 6/2024 2:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.48 31 14.83 515 237 0.24 / 815.71 2 3
2 12 1326.96 3 15.03 2091 94 0.33 / 815.80 2 3
3 7 2007.00 34 14.68 2797 1396 1.73 / 817.20 2 4
4 13 1515.08 20 14.68 2254 662 2.39 / 817.86 2 5
5 13 1007.40 20 14.70 1645 484 2.87 / 818.34 2 6
6 13 311.72 20 14.82 750 222 3.09 / 818.57 2 5
7 13 27.12 20 14.88 373 111 3.21 / 818.68 2 5
8 8 -0.08 165 14.84 322 788 3.99 / 819.47 2 17
Average= 3.94
(KJ/cycle)

Cycle 206 GMT 22/ 5/2024 3:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.08 31 14.82 534 245 0.25 / 811.71 2 3
2 12 1332.72 3 15.04 2090 94 0.34 / 811.80 2 3
3 7 2003.56 34 14.69 2790 1393 1.73 / 813.19 2 4
4 13 1665.52 20 14.67 2429 713 2.45 / 813.91 2 5
5 13 967.40 20 14.71 1598 470 2.92 / 814.38 2 6
6 13 305.80 20 14.82 742 220 3.14 / 814.60 2 5
7 13 29.72 20 14.88 367 109 3.25 / 814.71 2 5
8 8 0.00 165 14.85 312 764 4.01 / 815.47 2 14
Average= 3.94
(KJ/cycle)

Cycle 205 GMT 12/ 5/2024 5:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.16 31 14.82 519 238 0.24 / 807.75 2 3
2 12 1312.40 3 15.03 2077 94 0.33 / 807.85 2 3
3 7 2005.64 34 14.69 2775 1386 1.72 / 809.23 2 4
4 13 1489.24 20 14.69 2215 651 2.37 / 809.89 2 4
5 13 978.96 20 14.71 1610 474 2.84 / 810.36 2 5
6 13 294.72 20 14.83 720 214 3.06 / 810.57 2 5
7 13 52.00 20 14.88 402 120 3.18 / 810.69 2 5
8 8 0.12 165 14.85 314 769 3.95 / 811.46 2 16
Average= 3.94
(KJ/cycle)

Cycle 204 GMT 2/ 5/2024 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.88 31 14.83 500 230 0.23 / 803.78 2 3
2 12 1312.36 3 15.04 2065 93 0.32 / 803.87 2 3
3 7 2003.56 34 14.69 2791 1394 1.72 / 805.26 2 4
4 13 1510.52 20 14.69 2250 661 2.38 / 805.92 2 5
5 13 998.96 20 14.70 1642 483 2.86 / 806.41 2 6
6 13 322.72 20 14.82 768 228 3.09 / 806.63 2 5
7 13 30.88 20 14.88 369 110 3.20 / 806.74 2 5
8 8 -0.08 165 14.85 315 772 3.97 / 807.52 2 22
Average= 3.94
(KJ/cycle)

Cycle 203 GMT 22/ 4/2024 8:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.96 31 14.82 517 238 0.24 / 799.77 2 3
2 12 1324.64 3 15.02 2101 95 0.33 / 799.86 2 3
3 7 2005.20 34 14.69 2783 1390 1.72 / 801.25 2 4
4 13 1683.08 20 14.67 2435 714 2.44 / 801.97 2 5
5 13 974.44 20 14.71 1606 472 2.91 / 802.44 2 6
6 13 308.76 20 14.83 748 222 3.13 / 802.66 2 5
7 13 29.96 20 14.88 371 110 3.24 / 802.77 2 5
8 8 0.04 165 14.85 316 774 4.02 / 803.55 2 15
Average= 3.94
(KJ/cycle)

Cycle 202 GMT 12/ 4/2024 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.28 31 14.82 536 246 0.25 / 795.83 2 3
2 12 1319.24 3 15.03 2103 95 0.34 / 795.92 2 3
3 7 2002.56 34 14.69 2791 1394 1.74 / 797.32 2 4
4 13 1478.84 20 14.70 2207 649 2.38 / 797.96 2 5
5 13 977.52 20 14.71 1608 473 2.86 / 798.44 2 6
6 13 285.32 20 14.83 720 214 3.07 / 798.65 2 5
7 13 27.36 20 14.88 371 110 3.18 / 798.76 2 5
8 8 0.00 165 14.85 314 769 3.95 / 799.53 2 16
Average= 3.94
(KJ/cycle)

Cycle 201 GMT 2/ 4/2024 11:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.40 31 14.82 529 243 0.24 / 791.86 2 3
2 12 1302.40 3 15.04 2084 94 0.34 / 791.95 2 3
3 7 2003.12 34 14.68 2794 1395 1.73 / 793.34 2 4
4 13 1503.76 20 14.69 2232 656 2.39 / 794.00 2 5
5 13 985.92 20 14.71 1616 475 2.86 / 794.48 2 6
6 13 296.68 20 14.83 740 219 3.08 / 794.69 2 5
7 13 28.92 20 14.88 373 111 3.19 / 794.81 2 5
8 8 0.04 165 14.85 316 774 3.97 / 795.58 2 17
Average= 3.94
(KJ/cycle)

Cycle 200 GMT 23/ 3/2024 12:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.08 31 14.81 519 238 0.24 / 787.75 2 3
2 12 1310.36 3 15.03 2062 93 0.33 / 787.84 2 3
3 7 2002.32 34 14.69 2795 1396 1.73 / 789.24 2 4
4 13 1659.44 20 14.67 2425 711 2.44 / 789.95 2 5
5 13 1100.76 20 14.69 1767 519 2.96 / 790.47 2 6
6 13 388.48 20 14.81 852 252 3.21 / 790.72 2 5
7 13 41.56 20 14.88 393 117 3.33 / 790.84 2 5
8 8 -0.04 165 14.85 316 774 4.10 / 791.61 2 16
Average= 3.94
(KJ/cycle)

Cycle 199 GMT 13/ 3/2024 14:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.60 31 14.81 504 231 0.23 / 783.81 2 3
2 12 1280.36 3 15.03 2027 91 0.32 / 783.91 2 3
3 7 2001.24 34 14.68 2780 1388 1.71 / 785.29 2 4
4 13 1484.88 20 14.69 2218 652 2.36 / 785.94 2 5
5 13 980.84 20 14.71 1610 474 2.84 / 786.42 2 6
6 13 281.80 20 14.83 711 211 3.05 / 786.63 2 5
7 13 30.20 20 14.88 372 111 3.16 / 786.74 2 5
8 8 0.08 165 14.84 315 771 3.93 / 787.51 2 15
Average= 3.94
(KJ/cycle)

Cycle 198 GMT 3/ 3/2024 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.68 31 14.81 519 238 0.24 / 779.97 2 3
2 12 1313.28 3 15.04 2075 94 0.33 / 780.06 2 3
3 7 2004.64 34 14.69 2775 1386 1.72 / 781.45 2 4
4 13 1495.80 20 14.70 2218 652 2.37 / 782.10 2 5
5 13 866.84 20 14.73 1458 430 2.80 / 782.53 2 5
6 13 210.32 20 14.84 613 182 2.98 / 782.71 2 4
7 13 40.36 20 14.87 383 114 3.10 / 782.82 2 5
8 8 0.08 165 14.84 310 759 3.85 / 783.58 2 20
Average= 3.94
(KJ/cycle)

Cycle 197 GMT 22/ 2/2024 16:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.52 31 14.81 502 230 0.23 / 776.00 2 3
2 12 1330.60 3 15.05 2083 94 0.32 / 776.10 2 2
3 7 2003.24 34 14.70 2783 1391 1.72 / 777.49 2 4
4 13 1516.16 20 14.69 2257 663 2.38 / 778.15 2 4
5 13 1017.84 20 14.70 1650 485 2.86 / 778.64 2 5
6 13 314.88 20 14.81 751 222 3.09 / 778.86 2 5
7 13 29.48 20 14.87 365 109 3.19 / 778.97 2 4
8 8 0.00 165 14.84 310 759 3.95 / 779.73 2 13
Average= 3.94
(KJ/cycle)

Cycle 196 GMT 12/ 2/2024 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.40 31 14.82 511 235 0.23 / 772.03 2 3
2 12 1321.64 3 15.04 2091 94 0.33 / 772.13 2 3
3 7 2005.92 34 14.69 2786 1391 1.72 / 773.52 2 4
4 13 1521.52 20 14.69 2261 664 2.38 / 774.18 2 4
5 13 1021.20 20 14.70 1655 487 2.87 / 774.67 2 5
6 13 336.68 20 14.81 775 230 3.10 / 774.90 2 5
7 13 36.08 20 14.87 374 111 3.21 / 775.01 2 4
8 8 0.20 165 14.84 312 764 3.98 / 775.77 2 16
Average= 3.94
(KJ/cycle)

Cycle 195 GMT 2/ 2/2024 19:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.24 31 14.82 513 236 0.24 / 768.07 2 3
2 12 1326.84 3 15.04 2111 95 0.33 / 768.17 2 3
3 7 2004.52 34 14.70 2776 1387 1.72 / 769.55 2 3
4 13 1510.36 20 14.69 2242 659 2.38 / 770.21 2 5
5 13 1007.24 20 14.71 1645 484 2.86 / 770.70 2 6
6 13 329.56 20 14.81 774 229 3.09 / 770.93 2 5
7 13 33.28 20 14.88 372 111 3.20 / 771.04 2 5
8 8 0.12 165 14.85 311 762 3.96 / 771.80 2 16
Average= 3.94
(KJ/cycle)

Cycle 194 GMT 23/ 1/2024 21:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.12 31 14.83 524 241 0.24 / 764.02 3 3
2 12 1328.96 3 15.05 2106 95 0.34 / 764.12 2 3
3 7 2005.36 34 14.70 2786 1392 1.73 / 765.51 2 4
4 13 1659.88 20 14.68 2413 708 2.44 / 766.22 2 5
5 13 979.36 20 14.71 1609 473 2.91 / 766.69 2 5
6 13 451.52 20 14.79 926 274 3.18 / 766.96 2 5
7 13 27.84 20 14.88 365 109 3.29 / 767.07 2 4
8 8 0.08 165 14.85 311 762 4.05 / 767.84 2 17
Average= 3.94
(KJ/cycle)

Cycle 193 GMT 13/ 1/2024 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.12 31 14.82 520 239 0.24 / 760.05 2 3
2 12 1322.12 3 15.04 2094 94 0.33 / 760.15 2 3
3 7 2003.92 34 14.70 2788 1393 1.73 / 761.54 2 4
4 13 1499.00 20 14.70 2227 655 2.38 / 762.20 2 5
5 13 997.16 20 14.71 1629 479 2.86 / 762.68 2 5
6 13 328.04 20 14.82 762 226 3.09 / 762.90 2 5
7 13 29.88 20 14.88 378 112 3.20 / 763.01 2 5
8 8 0.00 165 14.85 313 767 3.97 / 763.78 2 15
Average= 3.94
(KJ/cycle)

Cycle 192 GMT 4/ 1/2024 0:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.28 31 14.83 524 241 0.24 / 756.08 2 3
2 12 1322.12 3 15.04 2070 93 0.33 / 756.17 2 3
3 7 2005.52 34 14.70 2789 1394 1.73 / 757.56 2 4
4 13 1509.96 20 14.70 2255 663 2.39 / 758.23 2 5
5 13 1011.48 20 14.71 1649 485 2.88 / 758.71 2 6
6 13 319.60 20 14.83 752 223 3.10 / 758.94 2 5
7 13 25.40 20 14.88 367 109 3.21 / 759.04 2 5
8 8 0.08 165 14.85 314 769 3.98 / 759.81 2 13
Average= 3.94
(KJ/cycle)

Cycle 191 GMT 25/12/2023 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.40 31 14.83 513 236 0.24 / 752.21 2 3
2 12 1308.12 3 15.06 2057 93 0.33 / 752.31 2 3
3 7 2005.08 34 14.70 2777 1388 1.72 / 753.69 2 4
4 13 1504.80 20 14.70 2235 657 2.37 / 754.35 2 5
5 13 998.92 20 14.71 1635 481 2.85 / 754.83 2 6
6 13 300.28 20 14.83 733 217 3.07 / 755.05 2 5
7 8 0.00 165 14.86 321 787 3.86 / 755.84 2 13
Average= 3.94
(KJ/cycle)

Cycle 190 GMT 15/12/2023 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.76 31 14.82 529 243 0.24 / 748.20 2 3
2 12 1334.44 3 15.04 2083 94 0.34 / 748.30 2 3
3 7 2003.28 34 14.70 2778 1388 1.73 / 749.68 2 4
4 13 1502.68 20 14.70 2231 656 2.38 / 750.34 2 5
5 13 996.48 20 14.72 1628 479 2.86 / 750.82 2 6
6 13 459.24 20 14.80 940 278 3.14 / 751.10 2 5
7 13 48.52 20 14.88 394 117 3.26 / 751.21 2 5
8 8 0.20 165 14.85 311 762 4.02 / 751.98 2 17
Average= 3.94
(KJ/cycle)

Cycle 189 GMT 5/12/2023 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.20 31 14.82 520 239 0.24 / 744.34 2 3
2 12 1319.00 3 15.05 2070 93 0.33 / 744.43 2 3
3 7 2004.80 34 14.70 2785 1392 1.72 / 745.83 2 4
4 13 1506.96 20 14.70 2243 659 2.38 / 746.49 2 5
5 13 879.00 20 14.73 1485 437 2.82 / 746.92 2 5
6 13 370.76 20 14.81 833 247 3.07 / 747.17 2 5
7 8 0.00 165 14.86 322 790 3.86 / 747.96 2 13
Average= 3.94
(KJ/cycle)

Cycle 188 GMT 25/11/2023 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.40 31 14.83 531 244 0.24 / 740.44 2 3
2 12 1323.56 3 15.04 2073 94 0.34 / 740.54 2 3
3 7 2005.88 34 14.70 2787 1393 1.73 / 741.93 2 3
4 13 1504.80 20 14.70 2240 659 2.39 / 742.59 2 5
5 13 997.60 20 14.71 1633 480 2.87 / 743.07 2 6
6 13 340.52 20 14.82 789 234 3.10 / 743.30 2 5
7 8 -0.04 165 14.86 326 799 3.90 / 744.10 2 14
Average= 3.94
(KJ/cycle)

Cycle 187 GMT 15/11/2023 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.56 31 14.83 529 243 0.24 / 736.55 2 3
2 12 1322.76 3 15.04 2106 95 0.34 / 736.65 2 3
3 7 2005.04 34 14.70 2790 1394 1.73 / 738.04 2 4
4 13 1516.32 20 14.70 2260 664 2.40 / 738.71 2 4
5 13 1009.92 20 14.71 1651 486 2.88 / 739.19 2 5
6 13 316.40 20 14.83 759 225 3.11 / 739.42 2 5
7 8 0.04 165 14.86 319 782 3.89 / 740.20 2 13
Average= 3.94
(KJ/cycle)

Cycle 186 GMT 5/11/2023 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.56 31 14.81 545 250 0.25 / 732.65 2 3
2 12 1322.80 3 15.05 2101 95 0.35 / 732.74 2 3
3 7 2002.16 34 14.70 2785 1392 1.74 / 734.14 2 4
4 13 1658.92 20 14.69 2418 710 2.45 / 734.85 2 4
5 13 974.28 20 14.72 1602 472 2.92 / 735.32 2 6
6 13 293.08 20 14.84 725 215 3.13 / 735.53 2 5
7 8 0.04 165 14.86 316 775 3.91 / 736.31 2 12
Average= 3.94
(KJ/cycle)

Cycle 185 GMT 26/10/2023 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.56 31 14.82 542 249 0.25 / 728.70 2 3
2 12 1336.72 3 15.04 2123 96 0.34 / 728.80 2 3
3 7 2005.96 35 14.71 2777 1430 1.77 / 730.23 2 3
4 13 1513.64 20 14.70 2261 665 2.44 / 730.89 2 4
5 13 995.20 20 14.72 1633 481 2.92 / 731.37 2 6
6 13 288.88 20 14.83 726 215 3.14 / 731.59 2 5
7 8 0.08 165 14.85 332 813 3.95 / 732.40 2 15
Average= 3.94
(KJ/cycle)

Cycle 184 GMT 16/10/2023 14:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.72 31 14.84 524 241 0.24 / 724.78 2 3
2 12 1332.84 3 15.05 2101 95 0.34 / 724.88 2 3
3 7 2003.60 34 14.71 2787 1394 1.73 / 726.27 2 4
4 13 1505.60 20 14.70 2255 663 2.39 / 726.93 2 5
5 13 1002.88 20 14.72 1643 484 2.88 / 727.42 2 5
6 13 292.24 20 14.84 740 220 3.10 / 727.64 2 5
7 8 0.12 165 14.87 332 815 3.91 / 728.45 2 15
Average= 3.94
(KJ/cycle)

Cycle 183 GMT 6/10/2023 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.84 31 14.83 549 252 0.25 / 720.87 2 3
2 3 1035.12 1 14.97 1750 26 0.28 / 720.89 2 4
3 12 1326.76 3 15.04 2089 94 0.37 / 720.99 2 3
4 7 2005.08 34 14.71 2782 1391 1.76 / 722.38 2 4
5 13 1504.08 20 14.71 2248 661 2.43 / 723.04 2 5
6 13 996.52 20 14.72 1639 483 2.91 / 723.52 2 5
7 13 311.16 20 14.84 755 224 3.13 / 723.75 2 5
8 8 0.00 165 14.87 323 792 3.92 / 724.54 2 13
Average= 3.94
(KJ/cycle)

Cycle 182 GMT 26/ 9/2023 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.24 31 14.83 541 249 0.25 / 716.88 2 3
2 12 1313.24 3 15.05 2096 95 0.34 / 716.97 2 3
3 7 2002.04 34 14.71 2782 1391 1.73 / 718.36 2 4
4 13 1656.96 20 14.70 2416 710 2.45 / 719.07 2 4
5 13 962.40 20 14.73 1594 470 2.91 / 719.54 2 6
6 13 442.48 20 14.81 926 274 3.19 / 719.82 2 5
7 8 0.00 165 14.87 326 800 3.99 / 720.62 2 11
Average= 3.94
(KJ/cycle)

Cycle 181 GMT 16/ 9/2023 20: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.52 31 14.83 533 245 0.25 / 712.98 2 3
2 12 1300.84 3 15.04 2085 94 0.34 / 713.07 2 3
3 7 2003.88 34 14.71 2784 1392 1.73 / 714.46 2 3
4 13 1497.60 20 14.71 2232 657 2.39 / 715.12 2 5
5 13 991.00 20 14.73 1626 479 2.87 / 715.60 2 6
6 13 302.64 20 14.85 749 222 3.09 / 715.82 2 5
7 8 0.24 165 14.87 328 805 3.89 / 716.63 2 20
Average= 3.94
(KJ/cycle)

Cycle 180 GMT 6/ 9/2023 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.72 31 14.84 532 245 0.24 / 709.07 2 3
2 12 1317.28 3 15.05 2105 95 0.34 / 709.17 2 3
3 7 2004.08 34 14.71 2795 1398 1.74 / 710.57 2 4
4 13 1512.20 20 14.71 2251 662 2.40 / 711.23 2 5
5 13 881.60 20 14.74 1492 440 2.84 / 711.67 2 6
6 13 374.88 20 14.82 851 252 3.09 / 711.92 2 5
7 8 -0.16 165 14.87 331 812 3.90 / 712.73 2 17
Average= 3.94
(KJ/cycle)

Cycle 179 GMT 27/ 8/2023 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.84 31 14.84 545 251 0.25 / 705.21 2 3
2 12 1318.20 3 15.04 2083 94 0.34 / 705.31 2 3
3 7 2004.96 34 14.71 2782 1391 1.74 / 706.70 2 3
4 13 1507.08 20 14.71 2222 654 2.39 / 707.35 2 4
5 13 1009.48 20 14.72 1655 487 2.88 / 707.84 2 6
6 13 180.00 20 14.87 583 173 3.05 / 708.01 2 4
7 8 0.20 165 14.87 333 817 3.87 / 708.83 2 15
Average= 3.94
(KJ/cycle)

Cycle 178 GMT 18/ 8/2023 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.84 31 14.84 535 246 0.25 / 701.30 2 3
2 12 1321.84 3 15.06 2092 95 0.34 / 701.40 2 3
3 7 2009.44 34 14.71 2790 1395 1.74 / 702.79 2 4
4 13 1515.80 20 14.71 2256 664 2.40 / 703.46 2 4
5 13 1010.72 20 14.73 1653 487 2.89 / 703.94 2 5
6 13 322.40 20 14.84 768 228 3.11 / 704.17 2 5
7 8 0.16 165 14.88 322 791 3.91 / 704.96 2 14
Average= 3.94
(KJ/cycle)

Cycle 177 GMT 8/ 8/2023 2:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.44 31 14.83 535 246 0.25 / 697.40 2 3
2 12 1320.56 3 15.04 2100 95 0.34 / 697.49 2 3
3 7 2003.36 34 14.72 2782 1392 1.73 / 698.88 2 4
4 13 1509.24 20 14.71 2251 662 2.40 / 699.55 2 5
5 13 1010.48 20 14.73 1650 486 2.88 / 700.03 2 5
6 13 322.44 20 14.84 766 227 3.11 / 700.26 2 5
7 8 0.12 165 14.88 324 795 3.90 / 701.06 2 14
Average= 3.94
(KJ/cycle)

Cycle 176 GMT 29/ 7/2023 4:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.88 30 14.85 532 237 0.24 / 693.48 2 3
2 12 1330.36 3 15.06 2093 95 0.33 / 693.57 2 3
3 7 2004.44 34 14.72 2763 1383 1.71 / 694.95 2 4
4 13 1498.92 20 14.72 2229 656 2.37 / 695.61 2 4
5 13 986.68 20 14.73 1621 478 2.85 / 696.09 2 5
6 13 442.80 20 14.82 920 273 3.12 / 696.36 2 5
7 8 0.08 165 14.88 322 791 3.91 / 697.15 2 15
Average= 3.94
(KJ/cycle)

Cycle 175 GMT 19/ 7/2023 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.72 30 14.85 541 241 0.24 / 689.60 2 3
2 12 1317.36 3 15.05 2073 94 0.33 / 689.69 2 3
3 7 2002.04 34 14.71 2784 1392 1.73 / 691.09 2 4
4 13 1500.88 20 14.71 2237 658 2.39 / 691.74 2 4
5 13 988.44 20 14.73 1623 478 2.86 / 692.22 2 5
6 13 314.60 20 14.85 763 227 3.09 / 692.45 2 5
7 8 0.20 165 14.89 322 791 3.88 / 693.24 2 12
Average= 3.94
(KJ/cycle)

Cycle 174 GMT 9/ 7/2023 7:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.36 30 14.85 519 231 0.23 / 685.74 2 3
2 12 1317.16 3 15.06 2075 94 0.32 / 685.83 2 3
3 7 2003.12 34 14.72 2772 1387 1.71 / 687.22 2 4
4 13 1500.64 20 14.72 2224 655 2.37 / 687.87 2 4
5 13 998.16 20 14.73 1637 482 2.85 / 688.36 2 5
6 13 308.92 20 14.86 745 221 3.07 / 688.58 2 5
7 8 0.24 165 14.89 318 781 3.85 / 689.36 2 12
Average= 3.94
(KJ/cycle)

Cycle 173 GMT 29/ 6/2023 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.60 31 14.85 535 246 0.25 / 681.67 2 3
2 12 1315.80 3 15.06 2086 94 0.34 / 681.77 2 3
3 7 2012.24 34 14.72 2796 1399 1.74 / 683.17 2 3
4 13 1514.12 20 14.72 2252 663 2.40 / 683.83 2 5
5 13 1001.20 20 14.73 1635 482 2.88 / 684.31 2 5
6 13 307.00 20 14.86 750 223 3.11 / 684.53 2 5
7 8 -0.04 165 14.89 328 806 3.91 / 685.34 2 12
8 14 -0.04 35 14.86 321 167 4.08 / 685.51 4 17
Average= 3.94
(KJ/cycle)

Cycle 172 GMT 19/ 6/2023 11:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.40 31 14.85 529 244 0.24 / 677.77 2 3
2 12 1320.28 3 15.05 2087 94 0.34 / 677.87 2 3
3 7 2003.64 34 14.72 2795 1399 1.74 / 679.26 2 4
4 13 1512.44 20 14.72 2244 661 2.40 / 679.93 2 4
5 13 1001.16 20 14.73 1637 482 2.88 / 680.41 2 5
6 13 309.72 20 14.86 759 226 3.11 / 680.63 2 5
7 8 0.04 165 14.89 323 794 3.90 / 681.43 2 16
Average= 3.94
(KJ/cycle)

Cycle 171 GMT 9/ 6/2023 12:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.40 31 14.86 533 246 0.25 / 673.81 2 3
2 12 1310.56 3 15.06 2074 94 0.34 / 673.90 2 3
3 7 2005.00 34 14.72 2783 1393 1.73 / 675.30 2 4
4 13 1509.20 20 14.72 2252 663 2.40 / 675.96 2 5
5 13 995.80 20 14.73 1635 482 2.88 / 676.44 2 5
6 13 452.76 20 14.82 945 280 3.16 / 676.72 2 5
7 8 0.08 165 14.88 328 805 3.96 / 677.53 2 14
Average= 3.94
(KJ/cycle)

Cycle 170 GMT 30/ 5/2023 14:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.12 31 14.86 530 244 0.24 / 669.93 2 3
2 12 1320.88 3 15.06 2099 95 0.34 / 670.02 2 3
3 7 2005.80 34 14.72 2779 1391 1.73 / 671.41 2 4
4 13 1499.56 20 14.72 2235 658 2.39 / 672.07 2 4
5 13 1001.92 20 14.73 1639 483 2.87 / 672.55 2 6
6 13 310.20 20 14.86 756 225 3.10 / 672.78 2 5
7 8 0.12 165 14.89 320 786 3.88 / 673.57 2 14
Average= 3.94
(KJ/cycle)

Cycle 169 GMT 20/ 5/2023 16:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.68 31 14.84 533 245 0.25 / 666.01 2 3
2 3 1017.52 1 15.02 1694 25 0.27 / 666.03 2 3
3 12 1315.92 3 15.06 2113 95 0.37 / 666.13 2 3
4 7 2005.40 34 14.72 2788 1395 1.76 / 667.52 2 3
5 13 1504.28 20 14.72 2245 661 2.42 / 668.19 2 5
6 13 994.56 20 14.73 1635 482 2.90 / 668.67 2 6
7 13 316.68 20 14.85 760 226 3.13 / 668.89 2 5
8 8 0.12 165 14.89 322 791 3.92 / 669.68 2 11
Average= 3.94
(KJ/cycle)

Cycle 168 GMT 10/ 5/2023 17:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.08 31 14.85 542 250 0.25 / 662.02 2 3
2 12 1317.56 3 15.05 2097 95 0.34 / 662.12 2 3
3 7 2001.64 34 14.72 2773 1388 1.73 / 663.50 2 4
4 13 1501.76 20 14.72 2237 659 2.39 / 664.16 2 4
5 13 987.44 20 14.74 1621 478 2.87 / 664.64 2 5
6 13 291.44 20 14.86 727 216 3.08 / 664.86 2 5
7 13 20.72 20 14.91 366 109 3.19 / 664.97 2 5
8 8 -0.20 165 14.87 325 797 3.99 / 665.76 2 18
Average= 3.94
(KJ/cycle)

Cycle 167 GMT 30/ 4/2023 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.96 31 14.85 522 240 0.24 / 657.99 2 3
2 3 1020.28 1 15.02 1713 26 0.27 / 658.01 2 3
3 12 1319.40 3 15.05 2098 95 0.36 / 658.11 2 3
4 7 2004.96 34 14.72 2787 1395 1.76 / 659.50 2 4
5 13 1498.00 20 14.72 2234 658 2.41 / 660.16 2 4
6 13 993.32 20 14.74 1635 482 2.90 / 660.64 2 6
7 13 317.04 20 14.85 761 226 3.12 / 660.87 2 5
8 13 24.96 20 14.91 376 112 3.23 / 660.98 2 5
9 8 0.00 165 14.88 322 791 4.02 / 661.77 2 13
Average= 3.94
(KJ/cycle)

Cycle 166 GMT 20/ 4/2023 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.16 31 14.85 539 248 0.25 / 654.08 2 3
2 12 1326.24 3 15.06 2086 94 0.34 / 654.18 2 3
3 7 2001.56 34 14.73 2782 1393 1.74 / 655.57 2 3
4 13 1519.20 20 14.72 2259 665 2.40 / 656.24 2 4
5 13 999.20 20 14.74 1644 485 2.89 / 656.72 2 6
6 13 316.12 20 14.86 764 227 3.11 / 656.95 2 5
7 8 0.08 165 14.89 326 801 3.91 / 657.75 2 13
Average= 3.94
(KJ/cycle)

Cycle 165 GMT 10/ 4/2023 22:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.68 31 14.85 545 251 0.25 / 650.15 2 3
2 12 1310.52 3 15.07 2080 94 0.34 / 650.24 2 3
3 7 2001.92 35 14.72 2786 1435 1.78 / 651.68 2 3
4 13 1491.80 20 14.72 2228 656 2.44 / 652.34 2 4
5 13 986.16 20 14.74 1621 478 2.91 / 652.81 2 6
6 13 290.92 20 14.86 735 218 3.13 / 653.03 2 5
7 8 0.24 165 14.89 327 803 3.94 / 653.83 2 12
Average= 3.94
(KJ/cycle)

Cycle 164 GMT 1/ 4/2023 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.84 31 14.85 533 245 0.25 / 646.15 2 3
2 12 1326.20 3 15.06 2117 96 0.34 / 646.24 2 3
3 7 2004.56 34 14.73 2782 1393 1.73 / 647.63 2 3
4 13 1508.84 20 14.72 2242 660 2.39 / 648.29 2 4
5 13 1003.44 20 14.74 1643 484 2.88 / 648.78 2 5
6 13 316.88 20 14.86 759 226 3.10 / 649.00 2 5
7 13 25.84 20 14.92 370 110 3.21 / 649.12 2 4
8 8 0.04 165 14.89 319 784 4.00 / 649.90 2 15
Average= 3.94
(KJ/cycle)

Cycle 163 GMT 22/ 3/2023 2:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.84 31 14.85 534 246 0.25 / 642.10 2 3
2 12 1320.92 3 15.06 2081 94 0.34 / 642.20 2 3
3 7 2004.12 34 14.73 2786 1395 1.74 / 643.59 2 3
4 13 1518.88 20 14.72 2254 664 2.40 / 644.26 2 4
5 13 1021.20 20 14.73 1665 491 2.89 / 644.75 2 6
6 13 334.16 20 14.85 784 233 3.12 / 644.98 2 5
7 13 25.40 20 14.91 376 112 3.23 / 645.09 2 5
8 8 0.12 165 14.88 329 808 4.04 / 645.90 2 15
Average= 3.94
(KJ/cycle)

Cycle 162 GMT 12/ 3/2023 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.04 31 14.85 540 249 0.25 / 638.12 2 3
2 12 1320.08 3 15.06 2062 93 0.34 / 638.22 2 3
3 7 2002.64 34 14.73 2774 1389 1.73 / 639.61 2 4
4 13 1498.72 20 14.73 2231 657 2.39 / 640.26 2 4
5 13 988.44 20 14.74 1621 478 2.87 / 640.74 2 5
6 13 304.56 20 14.86 743 221 3.09 / 640.96 2 4
7 13 24.28 20 14.92 368 110 3.20 / 641.07 2 5
8 8 0.08 165 14.89 320 786 3.98 / 641.86 2 14
Average= 3.94
(KJ/cycle)

Cycle 161 GMT 2/ 3/2023 6:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.48 31 14.84 536 247 0.25 / 634.13 2 3
2 12 1300.72 3 15.07 2053 93 0.34 / 634.22 2 3
3 7 2004.60 34 14.73 2786 1395 1.73 / 635.62 2 3
4 13 1508.96 20 14.72 2246 661 2.40 / 636.28 2 5
5 13 1002.64 20 14.74 1640 483 2.88 / 636.76 2 5
6 13 315.92 20 14.86 754 224 3.10 / 636.99 2 5
7 13 22.92 20 14.92 365 109 3.21 / 637.09 2 5
8 8 0.04 165 14.88 318 781 3.99 / 637.88 2 17
Average= 3.94
(KJ/cycle)

Cycle 160 GMT 20/ 2/2023 7:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.36 31 14.85 522 240 0.24 / 630.12 2 3
2 12 1310.88 3 15.07 2081 94 0.33 / 630.21 2 3
3 7 2002.12 34 14.72 2782 1392 1.73 / 631.61 2 3
4 13 1500.32 20 14.73 2229 657 2.38 / 632.26 2 4
5 13 999.52 20 14.75 1641 484 2.87 / 632.75 2 5
6 13 322.32 20 14.86 767 228 3.10 / 632.97 2 4
7 13 25.64 20 14.91 376 112 3.21 / 633.09 2 5
8 8 0.04 165 14.88 324 795 4.00 / 633.88 2 15
Average= 3.94
(KJ/cycle)

Cycle 159 GMT 10/ 2/2023 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.64 31 14.85 532 245 0.24 / 626.05 2 3
2 12 1332.48 3 15.07 2089 94 0.34 / 626.15 2 3
3 7 2003.44 34 14.73 2771 1388 1.73 / 627.54 2 3
4 13 1659.56 20 14.70 2408 708 2.44 / 628.24 2 4
5 13 971.44 20 14.75 1598 471 2.91 / 628.72 2 5
6 13 440.64 20 14.83 913 271 3.18 / 628.99 2 5
7 13 20.36 20 14.92 359 107 3.28 / 629.09 2 4
8 8 0.16 165 14.88 320 786 4.07 / 629.88 2 16
Average= 3.94
(KJ/cycle)

Cycle 158 GMT 31/ 1/2023 11:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.24 31 14.87 516 238 0.24 / 622.04 2 3
2 12 1322.52 3 15.06 2073 94 0.33 / 622.13 2 3
3 7 2006.80 35 14.72 2783 1434 1.77 / 623.57 2 4
4 13 1498.40 20 14.72 2222 654 2.42 / 624.22 2 4
5 13 992.44 20 14.74 1622 478 2.90 / 624.70 2 5
6 13 294.92 20 14.86 727 216 3.11 / 624.92 2 4
7 13 21.04 20 14.92 363 108 3.22 / 625.02 2 4
8 8 0.00 165 14.88 320 786 4.01 / 625.81 2 14
Average= 3.94
(KJ/cycle)

Cycle 157 GMT 21/ 1/2023 13:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.72 31 14.87 542 250 0.25 / 618.20 2 3
2 12 1324.24 3 15.07 2083 94 0.34 / 618.29 2 3
3 7 2002.92 35 14.73 2781 1434 1.78 / 619.72 2 3
4 13 1501.24 20 14.73 2233 658 2.44 / 620.38 2 4
5 13 997.24 20 14.75 1634 482 2.92 / 620.86 2 5
6 13 168.40 20 14.90 556 166 3.08 / 621.03 2 4
7 8 0.04 165 14.90 314 772 3.86 / 621.80 2 11
Average= 3.94
(KJ/cycle)

Cycle 156 GMT 11/ 1/2023 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.72 31 14.87 534 246 0.25 / 614.27 2 3
2 3 1025.20 1 15.03 1698 26 0.27 / 614.30 2 3
3 12 1322.60 3 15.08 2106 95 0.37 / 614.40 2 3
4 7 2004.80 34 14.74 2778 1392 1.76 / 615.79 2 3
5 13 1513.28 20 14.73 2249 663 2.42 / 616.45 2 4
6 13 1004.44 20 14.75 1643 485 2.91 / 616.93 2 5
7 13 322.64 20 14.87 771 229 3.14 / 617.16 2 4
8 8 0.08 165 14.91 318 782 3.92 / 617.95 2 11
Average= 3.94
(KJ/cycle)

Cycle 155 GMT 1/ 1/2023 16:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.88 31 14.86 540 249 0.25 / 610.37 2 3
2 12 1317.56 3 15.07 2061 93 0.34 / 610.47 2 3
3 7 2002.76 34 14.73 2777 1391 1.73 / 611.86 2 3
4 13 1496.88 20 14.73 2235 658 2.39 / 612.52 2 4
5 13 1004.96 20 14.75 1645 485 2.88 / 613.00 2 5
6 13 308.16 20 14.87 747 222 3.10 / 613.22 2 4
7 8 0.12 165 14.91 327 804 3.90 / 614.03 2 10
Average= 3.94
(KJ/cycle)

Cycle 154 GMT 22/12/2022 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.20 31 14.87 533 246 0.25 / 606.34 2 3
2 12 1307.28 3 15.07 2061 93 0.34 / 606.44 2 3
3 7 2002.92 34 14.73 2780 1392 1.73 / 607.83 2 4
4 13 1510.12 20 14.74 2241 661 2.39 / 608.49 2 5
5 13 1007.88 20 14.75 1654 488 2.88 / 608.98 2 5
6 13 312.52 20 14.87 759 226 3.11 / 609.20 2 5
7 13 20.92 20 14.93 368 110 3.22 / 609.31 2 4
8 8 0.08 165 14.90 330 811 4.03 / 610.13 2 16
Average= 3.94
(KJ/cycle)

Cycle 153 GMT 12/12/2022 20:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.92 31 14.87 515 237 0.24 / 602.44 2 3
2 12 1312.32 3 15.07 2083 94 0.33 / 602.53 2 3
3 7 2005.88 34 14.73 2782 1393 1.72 / 603.92 2 3
4 13 1511.24 20 14.73 2247 662 2.39 / 604.59 2 5
5 13 1001.28 20 14.75 1634 482 2.87 / 605.07 2 5
6 13 315.32 20 14.87 760 226 3.09 / 605.29 2 4
7 8 0.00 165 14.90 327 804 3.90 / 606.10 2 14
Average= 3.94
(KJ/cycle)

Cycle 152 GMT 2/12/2022 22: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.08 30 14.87 523 233 0.23 / 598.57 2 3
2 12 1321.64 3 15.08 2078 94 0.33 / 598.66 2 3
3 7 2004.68 34 14.73 2771 1388 1.72 / 600.05 2 4
4 13 1501.96 20 14.73 2235 658 2.37 / 600.71 2 5
5 13 999.64 20 14.75 1633 482 2.86 / 601.19 2 6
6 13 307.72 20 14.88 742 221 3.08 / 601.41 2 5
7 8 0.08 165 14.91 320 787 3.86 / 602.20 2 11
Average= 3.94
(KJ/cycle)

Cycle 151 GMT 22/11/2022 23:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.04 30 14.88 532 237 0.24 / 594.65 2 3
2 3 1037.08 1 15.01 1726 26 0.26 / 594.68 2 3
3 12 1334.64 3 15.08 2094 95 0.36 / 594.77 2 3
4 7 2006.24 34 14.74 2789 1398 1.76 / 596.17 2 3
5 13 1513.00 20 14.73 2249 663 2.42 / 596.83 2 5
6 13 1012.80 20 14.75 1653 488 2.91 / 597.32 2 5
7 13 329.84 20 14.87 775 230 3.14 / 597.55 2 4
8 8 0.12 165 14.91 320 787 3.92 / 598.34 2 10
Average= 3.94
(KJ/cycle)

Cycle 150 GMT 13/11/2022 1:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.88 30 14.88 527 235 0.24 / 590.77 2 3
2 12 1324.48 3 15.06 2098 95 0.33 / 590.86 2 3
3 7 2002.28 34 14.73 2787 1396 1.73 / 592.26 2 3
4 13 1512.60 20 14.73 2245 661 2.39 / 592.92 2 4
5 13 997.28 20 14.76 1634 482 2.87 / 593.40 2 6
6 13 316.84 20 14.88 757 225 3.09 / 593.62 2 4
7 8 0.04 165 14.92 320 788 3.88 / 594.41 2 14
Average= 3.94
(KJ/cycle)

Cycle 149 GMT 3/11/2022 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.52 30 14.88 539 241 0.24 / 586.89 2 3
2 12 1324.64 3 15.07 2079 94 0.33 / 586.98 2 3
3 7 2003.04 34 14.74 2778 1392 1.73 / 588.37 2 4
4 13 1500.80 20 14.74 2225 656 2.38 / 589.03 2 4
5 13 990.64 20 14.76 1629 481 2.86 / 589.51 2 5
6 13 303.52 20 14.88 745 222 3.09 / 589.73 2 5
7 8 0.04 165 14.92 325 800 3.89 / 590.53 2 13
Average= 3.94
(KJ/cycle)

Cycle 148 GMT 24/10/2022 4:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.96 30 14.87 547 244 0.24 / 582.94 2 3
2 12 1314.56 3 15.06 2089 94 0.34 / 583.04 2 3
3 7 2008.20 34 14.73 2791 1398 1.74 / 584.44 2 3
4 13 1538.08 20 14.73 2270 669 2.40 / 585.10 2 4
5 13 1021.48 20 14.75 1672 493 2.90 / 585.60 2 5
6 13 328.96 20 14.88 780 232 3.13 / 585.83 2 5
7 8 -0.04 165 14.92 331 815 3.95 / 586.64 2 14
Average= 3.94
(KJ/cycle)

Cycle 147 GMT 14/10/2022 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.24 30 14.88 531 237 0.24 / 579.07 2 3
2 12 1310.00 3 15.08 2081 94 0.33 / 579.17 2 3
3 7 2001.60 34 14.74 2781 1394 1.72 / 580.56 2 3
4 13 1382.28 20 14.74 2099 619 2.34 / 581.18 2 4
5 13 915.80 20 14.77 1539 455 2.80 / 581.63 2 6
6 13 393.24 20 14.86 866 257 3.06 / 581.89 2 5
7 8 0.12 165 14.92 328 807 3.86 / 582.70 2 9
Average= 3.94
(KJ/cycle)

Cycle 146 GMT 4/10/2022 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.44 30 14.87 541 241 0.24 / 575.10 2 3
2 12 1309.56 3 15.06 2087 94 0.34 / 575.19 2 3
3 7 2001.60 34 14.73 2794 1399 1.73 / 576.59 2 4
4 13 1502.96 20 14.74 2240 660 2.40 / 577.25 2 4
5 13 998.68 20 14.76 1644 485 2.88 / 577.73 2 6
6 13 475.08 20 14.84 975 289 3.17 / 578.02 2 5
7 8 0.00 165 14.92 330 812 3.98 / 578.84 2 13
Average= 3.94
(KJ/cycle)

Cycle 145 GMT 24/ 9/2022 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.56 30 14.87 548 244 0.24 / 571.12 2 3
2 12 1320.80 3 15.07 2104 95 0.34 / 571.21 2 3
3 7 2005.20 34 14.73 2796 1400 1.74 / 572.61 2 4
4 13 1509.04 20 14.74 2249 663 2.40 / 573.27 2 5
5 13 990.56 20 14.77 1630 482 2.88 / 573.76 2 5
6 13 451.76 20 14.85 945 281 3.17 / 574.04 2 5
7 8 0.16 165 14.92 332 817 3.98 / 574.85 2 15
Average= 3.94
(KJ/cycle)

Cycle 144 GMT 14/ 9/2022 11:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.52 30 14.87 545 243 0.24 / 567.16 2 3
2 12 1331.20 3 15.06 2100 95 0.34 / 567.25 2 3
3 7 2006.48 34 14.74 2799 1403 1.74 / 568.66 2 4
4 13 1515.28 20 14.74 2267 668 2.41 / 569.33 2 4
5 13 1014.96 20 14.75 1657 489 2.90 / 569.81 2 5
6 13 322.88 20 14.88 774 230 3.13 / 570.04 2 4
7 8 0.12 165 14.92 336 827 3.96 / 570.87 2 15
Average= 3.94
(KJ/cycle)

Cycle 143 GMT 4/ 9/2022 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.04 30 14.87 545 243 0.24 / 563.23 2 3
2 12 1316.84 3 15.08 2094 95 0.34 / 563.32 2 3
3 7 2002.56 34 14.73 2794 1399 1.74 / 564.72 2 4
4 13 1501.48 20 14.74 2248 663 2.40 / 565.39 2 4
5 13 997.36 20 14.76 1643 485 2.88 / 565.87 2 5
6 13 297.56 20 14.89 744 222 3.11 / 566.09 2 5
7 8 -0.04 165 14.92 335 825 3.93 / 566.92 2 12
Average= 3.94
(KJ/cycle)

Cycle 142 GMT 25/ 8/2022 14:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.00 30 14.87 532 237 0.24 / 559.30 2 3
2 12 1295.24 3 15.09 2051 93 0.33 / 559.40 2 2
3 7 2002.64 34 14.73 2783 1394 1.72 / 560.79 2 4
4 13 1505.88 20 14.74 2248 663 2.39 / 561.45 2 4
5 13 997.56 20 14.76 1642 485 2.87 / 561.94 2 5
6 13 318.76 20 14.88 771 229 3.10 / 562.17 2 4
7 8 0.12 165 14.91 332 817 3.92 / 562.99 2 13
Average= 3.94
(KJ/cycle)

Cycle 141 GMT 15/ 8/2022 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.04 30 14.88 531 237 0.24 / 555.23 2 3
2 12 1322.60 3 15.07 2090 94 0.33 / 555.32 2 3
3 7 2008.24 34 14.73 2793 1399 1.73 / 556.72 2 4
4 13 1503.60 20 14.74 2245 662 2.39 / 557.38 2 4
5 13 985.36 20 14.76 1622 479 2.87 / 557.86 2 5
6 13 297.20 20 14.89 740 220 3.09 / 558.08 2 4
7 8 0.16 165 14.92 330 812 3.90 / 558.90 2 16
8 14 0.16 35 14.89 330 172 4.08 / 559.07 6 16
Average= 3.94
(KJ/cycle)

Cycle 140 GMT 5/ 8/2022 18: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.68 30 14.89 534 239 0.24 / 551.32 2 3
2 12 1313.04 3 15.08 2086 94 0.33 / 551.41 2 3
3 7 2004.80 34 14.74 2785 1396 1.73 / 552.81 2 3
4 13 1506.04 20 14.74 2244 662 2.39 / 553.47 2 4
5 13 998.32 20 14.77 1642 485 2.88 / 553.95 2 5
6 13 308.68 20 14.89 756 225 3.10 / 554.18 2 4
7 8 0.24 165 14.92 330 812 3.91 / 554.99 2 15
Average= 3.94
(KJ/cycle)

Cycle 139 GMT 26/ 7/2022 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.52 30 14.88 539 241 0.24 / 547.39 2 3
2 12 1319.40 3 15.07 2084 94 0.33 / 547.49 2 3
3 7 2006.16 35 14.73 2789 1438 1.77 / 548.92 2 3
4 13 1505.72 20 14.74 2243 661 2.43 / 549.59 2 4
5 13 985.04 20 14.77 1615 477 2.91 / 550.06 2 5
6 13 288.44 20 14.90 724 216 3.13 / 550.28 2 4
7 8 0.04 165 14.93 325 801 3.93 / 551.08 2 16
Average= 3.94
(KJ/cycle)

Cycle 138 GMT 16/ 7/2022 21:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.16 30 14.88 542 242 0.24 / 543.46 2 3
2 12 1326.72 3 15.08 2101 95 0.34 / 543.56 2 3
3 7 2004.08 34 14.74 2797 1402 1.74 / 544.96 2 4
4 13 1510.88 20 14.74 2255 665 2.40 / 545.62 2 4
5 13 1008.60 20 14.77 1654 489 2.89 / 546.11 2 5
6 13 311.96 20 14.89 757 225 3.12 / 546.34 2 4
7 8 0.28 165 14.93 330 813 3.93 / 547.15 2 14
Average= 3.94
(KJ/cycle)

Cycle 137 GMT 6/ 7/2022 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.12 30 14.89 549 245 0.25 / 539.52 2 3
2 12 1327.84 3 15.08 2104 95 0.34 / 539.61 2 2
3 7 2004.20 34 14.74 2788 1397 1.74 / 541.01 2 3
4 13 1505.28 20 14.74 2245 662 2.40 / 541.67 2 5
5 13 1011.68 20 14.76 1651 487 2.89 / 542.16 2 5
6 13 315.60 20 14.89 763 227 3.11 / 542.39 2 4
7 8 -0.12 165 14.92 339 835 3.95 / 543.22 2 11
Average= 3.94
(KJ/cycle)

Cycle 136 GMT 27/ 6/2022 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.00 30 14.89 550 246 0.25 / 535.61 2 3
2 12 1324.24 3 15.08 2119 96 0.34 / 535.70 2 3
3 7 2002.28 34 14.74 2793 1400 1.74 / 537.10 2 3
4 13 1498.64 20 14.75 2234 659 2.40 / 537.76 2 5
5 13 986.08 20 14.77 1626 480 2.88 / 538.24 2 5
6 13 282.88 20 14.90 731 218 3.10 / 538.46 2 5
7 8 0.00 165 14.93 330 813 3.91 / 539.27 2 15
Average= 3.94
(KJ/cycle)

Cycle 135 GMT 17/ 6/2022 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.44 30 14.90 539 241 0.24 / 531.66 2 3
2 12 1313.16 3 15.08 2064 93 0.33 / 531.76 2 3
3 7 2003.16 34 14.74 2796 1401 1.74 / 533.16 2 3
4 13 1520.96 20 14.74 2264 667 2.40 / 533.83 2 5
5 13 1015.36 20 14.76 1664 491 2.89 / 534.32 2 6
6 13 317.36 20 14.89 767 228 3.12 / 534.55 2 4
7 8 0.08 165 14.93 331 815 3.94 / 535.36 2 11
Average= 3.94
(KJ/cycle)

Cycle 134 GMT 7/ 6/2022 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.12 30 14.89 542 242 0.24 / 527.77 2 3
2 3 1017.20 1 15.05 1717 26 0.27 / 527.79 2 3
3 12 1327.92 3 15.08 2115 96 0.36 / 527.89 2 3
4 7 2004.76 34 14.74 2784 1395 1.76 / 529.29 2 3
5 13 1501.60 20 14.74 2238 660 2.42 / 529.95 2 4
6 13 982.60 20 14.77 1628 481 2.90 / 530.43 2 5
7 13 179.20 20 14.93 583 174 3.07 / 530.60 2 4
8 8 0.12 165 14.93 334 823 3.90 / 531.42 2 12
Average= 3.94
(KJ/cycle)

Cycle 133 GMT 28/ 5/2022 5:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.36 30 14.90 526 235 0.24 / 523.88 2 3
2 12 1331.56 3 15.08 2098 95 0.33 / 523.98 2 3
3 7 2005.48 34 14.74 2803 1405 1.73 / 525.38 2 4
4 13 1513.52 20 14.74 2261 667 2.40 / 526.05 2 4
5 13 1003.52 20 14.77 1648 487 2.89 / 526.54 2 5
6 13 186.44 20 14.93 592 177 3.06 / 526.71 2 4
7 8 0.12 165 14.93 330 813 3.88 / 527.53 2 16
Average= 3.94
(KJ/cycle)

Cycle 132 GMT 18/ 5/2022 7:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.76 30 14.88 559 250 0.25 / 519.98 2 3
2 12 1312.16 3 15.07 2067 93 0.34 / 520.08 2 3
3 7 2003.92 34 14.74 2787 1397 1.74 / 521.47 2 4
4 13 1502.64 20 14.75 2245 662 2.40 / 522.13 2 4
5 13 1004.00 20 14.77 1646 486 2.89 / 522.62 2 5
6 13 316.92 20 14.90 770 229 3.12 / 522.85 2 4
7 8 0.12 165 14.94 324 799 3.92 / 523.65 2 13
Average= 3.94
(KJ/cycle)

Cycle 131 GMT 8/ 5/2022 8:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.20 30 14.89 535 239 0.24 / 515.93 2 3
2 12 1322.00 3 15.08 2095 95 0.33 / 516.02 2 3
3 7 2003.96 34 14.74 2793 1400 1.73 / 517.42 2 4
4 13 1491.36 20 14.75 2233 659 2.39 / 518.08 2 4
5 13 987.84 20 14.77 1628 481 2.87 / 518.56 2 5
6 13 306.28 20 14.90 762 227 3.10 / 518.79 2 4
7 13 22.40 20 14.96 376 112 3.21 / 518.90 2 4
8 8 0.00 165 14.92 338 832 4.04 / 519.73 2 13
Average= 3.94
(KJ/cycle)

Cycle 130 GMT 28/ 4/2022 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.72 30 14.90 526 235 0.24 / 511.80 2 3
2 12 1314.76 3 15.07 2079 94 0.33 / 511.89 2 3
3 7 2003.40 34 14.74 2784 1395 1.72 / 513.29 2 4
4 13 1494.24 20 14.75 2231 658 2.38 / 513.95 2 4
5 13 1149.48 20 14.75 1829 540 2.92 / 514.49 2 5
6 13 422.56 20 14.88 903 269 3.19 / 514.76 2 5
7 13 37.36 20 14.95 397 119 3.31 / 514.88 2 5
8 8 0.00 165 14.92 330 812 4.12 / 515.69 2 15
Average= 3.94
(KJ/cycle)

Cycle 129 GMT 18/ 4/2022 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.88 30 14.88 542 242 0.24 / 507.88 2 3
2 3 1019.64 1 15.04 1703 26 0.27 / 507.90 2 3
3 12 1325.88 3 15.08 2113 96 0.36 / 508.00 2 3
4 7 2001.92 34 14.75 2777 1393 1.76 / 509.39 2 3
5 13 1501.20 20 14.75 2242 661 2.42 / 510.05 2 4
6 13 1004.16 20 14.77 1649 487 2.90 / 510.54 2 5
7 13 307.28 20 14.90 762 227 3.13 / 510.76 2 4
8 8 0.00 165 14.94 325 801 3.93 / 511.57 2 14
Average= 3.94
(KJ/cycle)

Cycle 128 GMT 8/ 4/2022 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.04 30 14.89 532 238 0.24 / 503.78 2 3
2 12 1311.76 3 15.09 2070 94 0.33 / 503.88 2 3
3 7 2012.68 34 14.74 2801 1404 1.74 / 505.28 2 3
4 13 1518.04 20 14.74 2257 665 2.40 / 505.95 2 4
5 13 1010.12 20 14.77 1658 490 2.89 / 506.44 2 4
6 13 465.40 20 14.86 958 285 3.17 / 506.72 2 5
7 13 21.64 20 14.96 368 110 3.29 / 506.83 2 4
8 8 0.20 165 14.92 326 803 4.09 / 507.63 2 14
Average= 3.94
(KJ/cycle)

Cycle 127 GMT 29/ 3/2022 15:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.76 30 14.90 528 236 0.24 / 499.86 2 3
2 12 1326.00 3 15.09 2105 95 0.33 / 499.96 2 2
3 7 2001.68 34 14.75 2793 1401 1.73 / 501.36 2 3
4 13 1498.24 20 14.75 2232 658 2.39 / 502.02 2 4
5 13 860.00 20 14.80 1464 433 2.82 / 502.45 2 5
6 13 203.84 20 14.93 614 183 3.01 / 502.64 2 4
7 13 36.88 20 14.96 389 116 3.12 / 502.75 2 4
8 8 0.00 165 14.93 322 793 3.92 / 503.55 2 15
Average= 3.93
(KJ/cycle)

Cycle 126 GMT 19/ 3/2022 17: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.08 30 14.90 522 233 0.23 / 495.85 2 3
2 12 1315.92 3 15.09 2098 95 0.33 / 495.94 2 3
3 7 2002.80 34 14.75 2798 1403 1.73 / 497.34 2 3
4 13 1513.48 20 14.75 2263 668 2.40 / 498.01 2 4
5 13 1006.92 20 14.77 1650 487 2.89 / 498.50 2 5
6 13 320.48 20 14.90 767 229 3.12 / 498.73 2 4
7 13 26.88 20 14.96 375 112 3.23 / 498.84 2 4
8 8 0.04 165 14.93 320 788 4.02 / 499.63 2 13
Average= 3.93
(KJ/cycle)

Cycle 125 GMT 9/ 3/2022 18:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.04 30 14.89 537 240 0.24 / 491.83 2 3
2 12 1334.60 3 15.08 2125 96 0.34 / 491.93 2 2
3 7 2003.56 34 14.74 2791 1399 1.73 / 493.32 2 3
4 13 1522.72 20 14.75 2264 668 2.40 / 493.99 2 5
5 13 1008.84 20 14.77 1656 489 2.89 / 494.48 2 5
6 13 314.44 20 14.91 761 227 3.12 / 494.71 2 4
7 13 23.00 20 14.96 366 110 3.23 / 494.82 2 4
8 8 0.08 165 14.93 323 796 4.02 / 495.61 2 15
Average= 3.93
(KJ/cycle)

Cycle 124 GMT 27/ 2/2022 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.48 30 14.90 536 240 0.24 / 487.78 2 3
2 12 1318.36 3 15.09 2096 95 0.33 / 487.87 2 3
3 7 2002.88 35 14.74 2797 1443 1.78 / 489.32 2 3
4 13 1497.60 20 14.75 2239 661 2.44 / 489.98 2 4
5 13 984.72 20 14.78 1622 479 2.92 / 490.46 2 5
6 13 291.92 20 14.91 731 218 3.14 / 490.68 2 4
7 13 19.64 20 14.96 363 109 3.24 / 490.78 2 5
8 8 0.12 165 14.93 327 806 4.05 / 491.59 2 13
Average= 3.93
(KJ/cycle)

Cycle 123 GMT 17/ 2/2022 22:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.24 30 14.90 545 244 0.24 / 483.74 2 3
2 12 1320.76 3 15.08 2094 95 0.34 / 483.83 2 3
3 7 2004.80 35 14.74 2790 1439 1.78 / 485.27 2 3
4 13 1485.48 20 14.76 2219 655 2.43 / 485.93 2 4
5 13 981.40 20 14.78 1624 480 2.91 / 486.41 2 5
6 13 289.00 20 14.91 732 218 3.13 / 486.62 2 4
7 13 20.76 20 14.97 375 112 3.24 / 486.74 2 4
8 8 0.08 165 14.94 326 804 4.05 / 487.54 2 16
Average= 3.93
(KJ/cycle)

Cycle 122 GMT 7/ 2/2022 23:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.84 30 14.91 535 239 0.24 / 479.71 2 3
2 12 1324.96 3 15.08 2103 95 0.33 / 479.80 2 3
3 7 2007.40 34 14.75 2803 1406 1.74 / 481.21 2 3
4 13 1504.84 20 14.76 2236 660 2.40 / 481.87 2 4
5 13 992.12 20 14.78 1631 482 2.88 / 482.35 2 5
6 13 311.04 20 14.91 756 225 3.11 / 482.58 2 4
7 13 24.28 20 14.97 373 112 3.22 / 482.69 2 4
8 8 -0.08 165 14.94 326 804 4.02 / 483.49 2 13
Average= 3.93
(KJ/cycle)

Cycle 121 GMT 29/ 1/2022 1:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.76 30 14.91 534 239 0.24 / 475.69 2 3
2 12 1320.36 3 15.09 2075 94 0.33 / 475.79 2 3
3 7 2002.84 34 14.76 2783 1397 1.73 / 477.18 2 3
4 13 1497.80 20 14.76 2235 660 2.39 / 477.84 2 4
5 13 991.40 20 14.78 1634 483 2.87 / 478.33 2 5
6 13 313.24 20 14.91 761 227 3.10 / 478.55 2 4
7 13 24.04 20 14.97 373 112 3.21 / 478.67 2 4
8 8 0.04 165 14.94 326 804 4.01 / 479.47 2 14
Average= 3.93
(KJ/cycle)

Cycle 120 GMT 19/ 1/2022 3: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.56 30 14.91 527 236 0.24 / 471.66 2 3
2 12 1321.08 3 15.09 2081 94 0.33 / 471.75 2 3
3 7 2004.40 34 14.76 2791 1401 1.73 / 473.15 2 3
4 13 1505.52 20 14.76 2246 663 2.39 / 473.82 2 4
5 13 993.68 20 14.79 1640 485 2.88 / 474.30 2 5
6 13 309.80 20 14.92 759 226 3.11 / 474.53 2 4
7 13 24.12 20 14.98 375 112 3.22 / 474.64 2 4
8 8 -0.04 165 14.94 330 813 4.03 / 475.46 2 14
Average= 3.93
(KJ/cycle)

Cycle 119 GMT 9/ 1/2022 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.68 30 14.92 524 235 0.23 / 467.65 2 3
2 12 1321.12 3 15.09 2100 95 0.33 / 467.75 2 2
3 7 2002.72 34 14.76 2778 1394 1.72 / 469.14 2 4
4 13 1493.28 20 14.76 2237 660 2.38 / 469.80 2 4
5 13 987.12 20 14.79 1622 480 2.86 / 470.28 2 5
6 13 294.00 20 14.92 736 220 3.08 / 470.50 2 4
7 13 24.84 20 14.98 375 112 3.20 / 470.61 2 4
8 8 -0.04 165 14.94 329 811 4.01 / 471.42 2 13
Average= 3.93
(KJ/cycle)

Cycle 118 GMT 30/12/2021 6: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.12 30 14.90 533 238 0.24 / 463.74 2 3
2 12 1322.68 3 15.10 2094 95 0.33 / 463.83 2 3
3 7 2002.16 34 14.76 2785 1398 1.73 / 465.23 2 3
4 13 1507.00 20 14.76 2240 661 2.39 / 465.89 2 4
5 13 992.56 20 14.79 1641 485 2.88 / 466.38 2 5
6 13 306.00 20 14.92 752 224 3.10 / 466.60 2 4
7 8 0.08 165 14.95 331 816 3.92 / 467.42 2 14
Average= 3.93
(KJ/cycle)

Cycle 117 GMT 20/12/2021 7:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.32 30 14.91 516 231 0.23 / 459.63 2 3
2 3 1015.48 1 15.06 1695 26 0.26 / 459.65 2 3
3 12 1320.12 3 15.07 2116 96 0.35 / 459.75 2 3
4 7 2003.88 34 14.76 2791 1401 1.75 / 461.15 2 3
5 13 1495.52 20 14.77 2224 657 2.41 / 461.81 2 4
6 13 982.32 20 14.79 1622 480 2.89 / 462.28 2 4
7 13 451.80 20 14.88 942 280 3.17 / 462.57 2 5
8 13 18.84 20 14.98 369 111 3.28 / 462.68 2 4
9 8 -0.04 165 14.94 334 823 4.10 / 463.50 2 16
Average= 3.93
(KJ/cycle)

Cycle 116 GMT 10/12/2021 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.40 30 14.91 531 238 0.24 / 455.70 2 3
2 12 1318.04 3 15.08 2085 94 0.33 / 455.80 2 3
3 7 2005.16 34 14.75 2800 1404 1.74 / 457.20 2 3
4 13 1515.04 20 14.75 2263 668 2.40 / 457.87 2 4
5 13 1010.12 20 14.78 1658 490 2.89 / 458.36 2 5
6 13 317.20 20 14.92 763 228 3.12 / 458.59 2 4
7 8 0.04 165 14.95 328 809 3.93 / 459.40 2 11
Average= 3.93
(KJ/cycle)

Cycle 115 GMT 30/11/2021 11: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.80 30 14.91 524 234 0.23 / 451.79 2 3
2 12 1325.40 3 15.10 2104 95 0.33 / 451.89 2 3
3 7 2002.12 34 14.76 2776 1393 1.72 / 453.28 2 3
4 13 1496.56 20 14.76 2240 661 2.38 / 453.94 2 4
5 13 986.32 20 14.79 1627 481 2.87 / 454.42 2 5
6 13 298.88 20 14.92 741 221 3.09 / 454.64 2 4
7 8 0.16 165 14.95 333 821 3.91 / 455.47 2 11
Average= 3.93
(KJ/cycle)

Cycle 114 GMT 20/11/2021 12:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.12 30 14.90 538 240 0.24 / 447.87 2 3
2 12 1332.20 3 15.10 2106 95 0.34 / 447.97 2 3
3 7 2001.72 34 14.76 2775 1393 1.73 / 449.36 2 3
4 13 1510.08 20 14.76 2247 663 2.39 / 450.03 2 4
5 13 996.36 20 14.79 1640 485 2.88 / 450.51 2 5
6 13 303.40 20 14.92 744 222 3.10 / 450.73 2 4
7 8 0.24 165 14.95 334 824 3.92 / 451.56 2 13
Average= 3.93
(KJ/cycle)

Cycle 113 GMT 10/11/2021 14:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.24 30 14.91 545 244 0.24 / 443.76 2 3
2 12 1320.76 3 15.09 2108 95 0.34 / 443.85 2 2
3 7 2005.08 34 14.76 2798 1404 1.74 / 445.26 2 3
4 13 1516.36 20 14.76 2260 667 2.41 / 445.92 2 4
5 13 1006.96 20 14.79 1656 490 2.90 / 446.41 2 5
6 13 318.48 20 14.91 768 229 3.13 / 446.64 2 4
7 8 0.04 165 14.95 332 819 3.95 / 447.46 2 13
8 14 0.04 35 14.92 332 173 4.12 / 447.63 3 14
Average= 3.93
(KJ/cycle)

Cycle 112 GMT 31/10/2021 15:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.36 30 14.90 564 252 0.25 / 439.80 2 3
2 12 1319.84 3 15.10 2098 95 0.35 / 439.90 2 3
3 7 2001.76 35 14.76 2786 1439 1.79 / 441.34 2 3
4 13 1499.72 20 14.77 2246 663 2.45 / 442.00 2 4
5 13 980.04 20 14.79 1621 479 2.93 / 442.48 2 4
6 13 278.16 20 14.93 717 214 3.14 / 442.70 2 4
7 8 0.12 165 14.95 331 816 3.96 / 443.51 2 13
Average= 3.92
(KJ/cycle)

Cycle 111 GMT 21/10/2021 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.56 30 14.90 552 247 0.25 / 435.87 2 3
2 12 1312.16 3 15.10 2087 95 0.34 / 435.97 2 3
3 7 2001.60 34 14.76 2796 1403 1.74 / 437.37 2 3
4 13 1485.76 20 14.77 2227 658 2.40 / 438.03 2 4
5 13 982.08 20 14.80 1624 481 2.88 / 438.51 2 5
6 13 286.60 20 14.93 728 217 3.10 / 438.73 2 4
7 8 0.12 165 14.95 335 826 3.93 / 439.55 2 13
Average= 3.92
(KJ/cycle)

Cycle 110 GMT 11/10/2021 19: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.44 30 14.90 550 246 0.25 / 431.92 2 3
2 12 1323.04 3 15.10 2093 95 0.34 / 432.02 2 2
3 7 2004.08 34 14.77 2776 1394 1.73 / 433.41 2 3
4 13 1514.76 20 14.76 2242 662 2.40 / 434.07 2 4
5 13 1006.96 20 14.79 1654 489 2.89 / 434.56 2 5
6 13 313.80 20 14.92 767 229 3.11 / 434.79 2 4
7 8 0.04 165 14.95 338 834 3.95 / 435.63 2 14
Average= 3.92
(KJ/cycle)

Cycle 109 GMT 1/10/2021 20:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.32 30 14.91 547 245 0.24 / 427.97 2 3
2 12 1320.72 3 15.12 2089 95 0.34 / 428.06 2 3
3 7 2005.32 34 14.76 2788 1399 1.74 / 429.46 2 3
4 13 1505.16 20 14.77 2251 665 2.40 / 430.13 2 4
5 13 1007.04 20 14.79 1650 488 2.89 / 430.61 2 5
6 13 316.64 20 14.92 767 229 3.12 / 430.84 2 4
7 8 0.00 165 14.95 338 834 3.95 / 431.68 2 9
Average= 3.92
(KJ/cycle)

Cycle 108 GMT 21/ 9/2021 22:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.04 30 14.91 557 249 0.25 / 424.02 2 3
2 12 1329.88 3 15.10 2105 95 0.34 / 424.12 2 3
3 7 2003.32 34 14.76 2795 1403 1.75 / 425.52 2 4
4 13 1510.52 20 14.77 2259 667 2.41 / 426.19 2 4
5 13 995.20 20 14.80 1639 485 2.90 / 426.67 2 5
6 13 286.76 20 14.94 727 217 3.12 / 426.89 2 4
7 8 0.08 165 14.96 338 834 3.95 / 427.72 2 13
Average= 3.92
(KJ/cycle)

Cycle 107 GMT 11/ 9/2021 23:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.72 30 14.90 549 245 0.25 / 420.01 2 2
2 12 1313.68 3 15.10 2086 94 0.34 / 420.11 2 3
3 7 2002.04 34 14.76 2794 1402 1.74 / 421.51 2 3
4 13 1500.20 20 14.77 2243 663 2.40 / 422.17 2 4
5 13 981.48 20 14.81 1626 482 2.89 / 422.65 2 5
6 13 439.20 20 14.90 927 276 3.16 / 422.93 2 4
7 8 0.04 165 14.95 341 841 4.00 / 423.77 2 13
Average= 3.92
(KJ/cycle)

Cycle 106 GMT 2/ 9/2021 1:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.88 30 14.90 549 245 0.25 / 416.07 2 3
2 12 1308.04 3 15.11 2056 93 0.34 / 416.17 2 3
3 7 2003.96 34 14.77 2780 1396 1.73 / 417.56 2 3
4 13 1503.52 20 14.77 2250 665 2.40 / 418.23 2 4
5 13 984.08 20 14.81 1624 481 2.88 / 418.71 2 5
6 13 302.92 20 14.93 751 224 3.10 / 418.93 2 4
7 8 0.32 165 14.95 339 836 3.94 / 419.77 2 15
Average= 3.92
(KJ/cycle)

Cycle 105 GMT 23/ 8/2021 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.20 30 14.91 546 244 0.24 / 412.00 2 3
2 12 1316.48 3 15.10 2100 95 0.34 / 412.10 2 2
3 7 2002.40 34 14.77 2790 1401 1.74 / 413.50 2 3
4 13 1510.12 20 14.77 2249 664 2.40 / 414.16 2 4
5 13 999.00 20 14.80 1645 487 2.89 / 414.65 2 5
6 13 305.88 20 14.93 754 225 3.12 / 414.87 2 4
7 13 19.48 20 14.98 382 114 3.23 / 414.99 2 4
8 8 -0.08 165 14.94 341 841 4.07 / 415.83 2 16
Average= 3.92
(KJ/cycle)

Cycle 104 GMT 13/ 8/2021 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.08 30 14.91 554 248 0.25 / 408.06 2 3
2 12 1311.80 3 15.11 2075 94 0.34 / 408.15 2 3
3 7 2003.96 34 14.77 2784 1398 1.74 / 409.55 2 3
4 13 1498.16 20 14.77 2229 658 2.40 / 410.21 2 4
5 13 996.68 20 14.80 1643 486 2.88 / 410.69 2 4
6 13 308.72 20 14.93 760 227 3.11 / 410.92 2 4
7 8 0.12 165 14.96 338 834 3.95 / 411.76 2 12
Average= 3.92
(KJ/cycle)

Cycle 103 GMT 3/ 8/2021 6:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.80 30 14.90 548 245 0.24 / 404.13 2 3
2 12 1325.52 3 15.10 2093 95 0.34 / 404.22 2 3
3 7 2003.80 34 14.77 2786 1399 1.74 / 405.62 2 3
4 13 1503.48 20 14.78 2236 661 2.40 / 406.28 2 4
5 13 986.72 20 14.81 1621 480 2.88 / 406.76 2 5
6 13 276.56 20 14.94 712 213 3.09 / 406.98 2 4
7 8 0.12 165 14.96 338 834 3.93 / 407.81 2 12
Average= 3.92
(KJ/cycle)

Cycle 102 GMT 24/ 7/2021 8:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.92 30 14.90 544 243 0.24 / 400.18 2 3
2 12 1309.00 3 15.11 2047 93 0.34 / 400.27 2 2
3 7 2002.40 34 14.77 2793 1403 1.74 / 401.68 2 3
4 13 1505.28 20 14.77 2236 661 2.40 / 402.34 2 4
5 13 1002.24 20 14.80 1637 485 2.88 / 402.82 2 4
6 13 314.76 20 14.93 762 228 3.11 / 403.05 2 4
7 8 0.08 165 14.95 338 834 3.94 / 403.88 2 12
Average= 3.92
(KJ/cycle)

Cycle 101 GMT 14/ 7/2021 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.24 30 14.91 544 243 0.24 / 396.30 2 3
2 12 1314.64 3 15.12 2100 95 0.34 / 396.39 2 2
3 7 2002.36 34 14.77 2771 1392 1.73 / 397.78 2 3
4 13 1487.52 20 14.78 2214 654 2.38 / 398.44 2 5
5 13 968.00 20 14.81 1602 475 2.86 / 398.91 2 5
6 13 264.68 20 14.94 694 207 3.07 / 399.12 2 4
7 8 0.20 165 14.96 332 820 3.89 / 399.94 2 10
Average= 3.92
(KJ/cycle)

Cycle 100 GMT 4/ 7/2021 11: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.68 30 14.92 551 247 0.25 / 392.37 2 3
2 12 1332.28 3 15.11 2082 94 0.34 / 392.46 2 2
3 7 2001.84 34 14.77 2777 1395 1.74 / 393.86 2 3
4 13 1507.68 20 14.77 2246 663 2.40 / 394.52 2 4
5 13 996.44 20 14.81 1643 487 2.89 / 395.01 2 5
6 13 312.04 20 14.94 751 224 3.11 / 395.23 2 4
7 8 0.28 165 14.96 333 822 3.93 / 396.05 2 12
Average= 3.92
(KJ/cycle)

Cycle 99 GMT 24/ 6/2021 12:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.08 30 14.90 558 249 0.25 / 388.44 2 3
2 12 1318.88 3 15.11 2061 93 0.34 / 388.54 2 2
3 7 2002.48 36 14.76 2779 1477 1.82 / 390.01 2 3
4 13 1488.16 20 14.77 2220 656 2.48 / 390.67 2 4
5 13 980.68 20 14.80 1611 477 2.95 / 391.14 2 4
6 13 151.52 20 14.97 545 163 3.12 / 391.31 2 4
7 8 -0.12 165 14.96 329 812 3.93 / 392.12 2 13
Average= 3.92
(KJ/cycle)

Cycle 98 GMT 14/ 6/2021 14:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.52 30 14.92 549 246 0.25 / 384.46 2 3
2 12 1325.64 3 15.11 2072 94 0.34 / 384.55 2 2
3 7 2002.44 36 14.76 2779 1477 1.82 / 386.03 2 3
4 13 1364.68 20 14.78 2074 613 2.43 / 386.64 2 4
5 13 1024.88 20 14.80 1671 495 2.92 / 387.14 2 4
6 13 307.00 20 14.93 750 224 3.15 / 387.36 2 4
7 8 0.04 165 14.96 336 829 3.98 / 388.19 2 14
Average= 3.92
(KJ/cycle)

Cycle 97 GMT 4/ 6/2021 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.44 30 14.92 545 244 0.24 / 380.43 2 3
2 3 1026.04 1 15.07 1716 26 0.27 / 380.45 2 3
3 12 1326.24 3 15.11 2094 95 0.36 / 380.55 2 3
4 7 2005.72 36 14.77 2795 1486 1.85 / 382.03 2 3
5 13 1493.24 20 14.77 2231 659 2.51 / 382.69 2 4
6 13 985.48 20 14.81 1627 482 2.99 / 383.17 2 4
7 13 280.04 20 14.94 718 215 3.21 / 383.39 2 4
8 8 0.08 165 14.96 335 827 4.03 / 384.22 2 7
Average= 3.92
(KJ/cycle)

Cycle 96 GMT 25/ 5/2021 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.36 30 14.93 542 243 0.24 / 376.56 2 3
2 12 1321.72 3 15.10 2085 94 0.34 / 376.66 2 3
3 7 2002.68 36 14.76 2774 1474 1.81 / 378.13 2 3
4 13 1355.92 20 14.79 2052 607 2.42 / 378.74 2 4
5 13 876.72 20 14.83 1486 441 2.86 / 379.18 2 5
6 13 202.68 20 14.96 620 186 3.04 / 379.36 2 4
7 8 0.00 165 14.96 332 820 3.86 / 380.18 2 15
Average= 3.92
(KJ/cycle)

Cycle 95 GMT 15/ 5/2021 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.12 30 14.93 545 244 0.24 / 372.68 2 3
2 12 1327.56 3 15.11 2104 95 0.34 / 372.78 2 2
3 7 2001.56 36 14.76 2781 1478 1.82 / 374.26 2 3
4 13 1485.40 20 14.78 2226 658 2.48 / 374.91 2 4
5 13 835.48 20 14.84 1431 425 2.90 / 375.34 2 5
6 13 154.80 20 14.98 548 164 3.06 / 375.50 2 4
7 8 -0.12 165 14.97 330 815 3.88 / 376.32 2 11
Average= 3.92
(KJ/cycle)

Cycle 94 GMT 5/ 5/2021 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.12 30 14.93 553 248 0.25 / 368.76 2 3
2 12 1330.16 3 15.11 2082 94 0.34 / 368.86 2 3
3 7 2005.88 36 14.77 2770 1473 1.81 / 370.33 2 4
4 13 1473.52 20 14.78 2190 647 2.46 / 370.98 2 4
5 13 821.28 20 14.85 1395 414 2.88 / 371.39 2 5
6 13 303.68 20 14.94 746 223 3.10 / 371.61 2 4
7 8 0.28 165 14.97 334 825 3.92 / 372.44 2 12
Average= 3.92
(KJ/cycle)

Cycle 93 GMT 25/ 4/2021 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.92 30 14.92 547 245 0.24 / 364.81 2 3
2 3 1021.48 1 15.08 1723 26 0.27 / 364.83 2 3
3 12 1321.88 3 15.11 2081 94 0.37 / 364.93 2 3
4 7 2002.96 36 14.77 2772 1474 1.84 / 366.40 2 3
5 13 1498.16 20 14.78 2240 662 2.50 / 367.06 2 4
6 13 977.40 20 14.81 1617 479 2.98 / 367.54 2 4
7 13 145.92 20 14.98 541 162 3.14 / 367.70 2 4
8 8 -0.08 165 14.98 328 811 3.95 / 368.51 2 13
Average= 3.92
(KJ/cycle)

Cycle 92 GMT 16/ 4/2021 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.96 30 14.92 546 244 0.24 / 360.82 2 3
2 12 1325.12 3 15.10 2105 95 0.34 / 360.91 2 2
3 7 2003.92 36 14.77 2785 1481 1.82 / 362.39 2 3
4 13 1500.84 20 14.78 2235 661 2.48 / 363.05 2 4
5 13 983.00 20 14.82 1616 479 2.96 / 363.53 2 5
6 13 281.36 20 14.95 715 214 3.17 / 363.75 2 4
7 8 0.08 165 14.97 330 815 3.99 / 364.56 2 11
Average= 3.92
(KJ/cycle)

Cycle 91 GMT 6/ 4/2021 1:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.84 30 14.92 539 241 0.24 / 356.77 2 3
2 12 1317.60 3 15.11 2095 95 0.34 / 356.86 2 3
3 7 2003.00 37 14.77 2789 1524 1.86 / 358.39 2 3
4 13 1489.12 20 14.79 2217 656 2.52 / 359.04 2 4
5 13 838.04 20 14.85 1436 426 2.94 / 359.47 2 4
6 13 169.48 20 14.97 572 171 3.11 / 359.64 2 4
7 13 29.88 20 15.00 383 115 3.23 / 359.76 2 4
8 8 0.32 165 14.96 330 815 4.04 / 360.57 2 11
Average= 3.92
(KJ/cycle)

Cycle 90 GMT 27/ 3/2021 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.88 30 14.92 545 244 0.24 / 352.52 2 2
2 12 1326.36 3 15.12 2075 94 0.34 / 352.61 2 2
3 7 2002.72 36 14.78 2762 1470 1.81 / 354.08 2 3
4 13 1491.88 20 14.78 2229 659 2.47 / 354.74 2 4
5 13 968.76 20 14.82 1606 476 2.94 / 355.22 2 4
6 13 259.44 20 14.96 689 206 3.15 / 355.42 2 4
7 13 17.68 20 15.00 367 110 3.26 / 355.53 2 4
8 8 -0.04 165 14.96 332 820 4.08 / 356.35 2 14
9 14 -0.04 35 14.93 336 176 4.25 / 356.53 4 15
Average= 3.92
(KJ/cycle)

Cycle 89 GMT 17/ 3/2021 4:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.12 30 14.93 543 243 0.24 / 348.42 2 3
2 12 1324.36 3 15.12 2093 95 0.34 / 348.51 2 3
3 7 2003.84 36 14.77 2789 1483 1.82 / 349.99 2 4
4 13 1493.00 20 14.78 2243 663 2.48 / 350.66 2 4
5 13 971.16 20 14.82 1606 476 2.96 / 351.13 2 5
6 13 249.32 20 14.95 681 204 3.16 / 351.34 2 4
7 13 17.40 20 15.00 372 112 3.28 / 351.45 2 4
8 8 -0.12 165 14.96 335 827 4.10 / 352.27 2 14
Average= 3.91
(KJ/cycle)

Cycle 88 GMT 7/ 3/2021 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.40 30 14.93 547 245 0.25 / 344.49 2 3
2 12 1319.60 3 15.12 2101 95 0.34 / 344.58 2 3
3 7 2000.96 36 14.77 2778 1477 1.82 / 346.06 2 3
4 13 1483.44 20 14.79 2220 657 2.47 / 346.72 2 4
5 13 957.48 20 14.82 1594 472 2.95 / 347.19 2 5
6 13 132.44 20 14.99 523 157 3.10 / 347.35 2 4
7 8 0.04 165 14.98 334 826 3.93 / 348.17 2 11
Average= 3.91
(KJ/cycle)

Cycle 87 GMT 25/ 2/2021 8: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.40 30 14.94 543 243 0.24 / 340.46 2 3
2 12 1333.16 3 15.12 2118 96 0.34 / 340.56 2 2
3 7 2004.20 36 14.79 2787 1484 1.82 / 342.04 2 3
4 13 1515.64 20 14.79 2260 669 2.49 / 342.71 2 4
5 13 992.84 20 14.82 1636 485 2.98 / 343.20 2 5
6 13 291.88 20 14.95 735 220 3.20 / 343.42 2 4
7 8 0.08 165 14.98 334 826 4.02 / 344.24 2 10
Average= 3.91
(KJ/cycle)

Cycle 86 GMT 15/ 2/2021 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.48 30 14.94 557 250 0.25 / 336.42 2 3
2 3 1016.16 1 15.12 1694 26 0.28 / 336.44 2 3
3 12 1320.24 3 15.12 2103 95 0.37 / 336.54 2 2
4 7 2003.44 37 14.77 2783 1521 1.89 / 338.06 2 3
5 13 1477.16 20 14.79 2218 656 2.55 / 338.71 2 4
6 13 964.80 20 14.83 1600 475 3.02 / 339.19 2 4
7 13 241.20 20 14.96 669 200 3.22 / 339.39 2 4
8 8 0.00 165 14.98 337 833 4.06 / 340.22 2 11
Average= 3.91
(KJ/cycle)

Cycle 85 GMT 5/ 2/2021 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.76 29 14.93 553 239 0.24 / 332.48 2 3
2 12 1326.48 3 15.12 2105 95 0.33 / 332.58 2 2
3 7 2001.56 36 14.78 2774 1476 1.81 / 334.05 2 3
4 13 1487.08 20 14.80 2203 652 2.46 / 334.71 2 4
5 13 970.28 20 14.83 1593 472 2.94 / 335.18 2 4
6 13 139.88 20 15.00 522 157 3.09 / 335.34 2 4
7 8 0.28 165 14.98 336 830 3.92 / 336.17 2 11
Average= 3.91
(KJ/cycle)

Cycle 84 GMT 26/ 1/2021 12:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.96 30 14.94 546 245 0.24 / 328.51 2 3
2 12 1311.88 3 15.13 2078 94 0.34 / 328.60 2 2
3 7 2004.20 36 14.78 2793 1486 1.83 / 330.09 2 3
4 13 1359.92 18 14.81 2082 555 2.38 / 330.64 2 4
5 13 1027.84 18 14.82 1675 447 2.83 / 331.09 2 5
6 13 327.16 18 14.95 793 213 3.04 / 331.30 2 4
7 13 14.52 18 15.01 373 101 3.14 / 331.40 2 4
8 8 0.00 165 14.97 340 840 3.98 / 332.24 2 13
Average= 3.91
(KJ/cycle)

Cycle 83 GMT 16/ 1/2021 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.56 29 14.95 544 236 0.24 / 324.52 2 2
2 3 1028.36 1 15.09 1714 26 0.26 / 324.55 2 3
3 12 1318.72 3 15.14 2095 95 0.36 / 324.64 2 2
4 7 2001.72 36 14.79 2773 1476 1.83 / 326.12 2 3
5 13 1491.08 18 14.81 2212 590 2.42 / 326.71 2 4
6 13 989.96 18 14.84 1623 434 2.86 / 327.14 2 4
7 13 306.36 18 14.96 750 202 3.06 / 327.34 2 4
8 13 13.88 18 15.02 361 98 3.16 / 327.44 2 4
9 8 0.04 165 14.98 332 821 3.98 / 328.26 2 14
Average= 3.91
(KJ/cycle)

Cycle 82 GMT 6/ 1/2021 15:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.48 29 14.95 550 238 0.24 / 320.63 2 3
2 3 1017.76 1 15.11 1708 26 0.26 / 320.65 2 3
3 12 1330.88 3 15.12 2101 95 0.36 / 320.75 2 3
4 7 2003.04 36 14.79 2775 1478 1.84 / 322.23 2 3
5 13 1484.64 18 14.81 2224 593 2.43 / 322.82 2 4
6 13 972.76 18 14.84 1605 429 2.86 / 323.25 2 4
7 13 291.92 18 14.97 736 198 3.06 / 323.45 2 4
8 8 0.08 165 14.99 340 841 3.90 / 324.29 2 11
Average= 3.91
(KJ/cycle)

Cycle 81 GMT 27/12/2020 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.72 29 14.94 556 241 0.24 / 316.74 2 3
2 12 1320.84 3 15.15 2067 94 0.33 / 316.83 2 2
3 7 2001.16 36 14.79 2793 1487 1.82 / 318.32 2 3
4 13 1487.64 17 14.81 2227 561 2.38 / 318.88 2 4
5 13 995.64 17 14.84 1643 414 2.80 / 319.29 2 4
6 13 498.80 17 14.93 1003 255 3.05 / 319.55 2 4
7 8 0.20 165 14.99 339 838 3.89 / 320.39 2 12
Average= 3.91
(KJ/cycle)

Cycle 80 GMT 17/12/2020 19: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.40 29 14.95 548 238 0.24 / 312.77 2 2
2 12 1310.56 3 15.15 2071 94 0.33 / 312.86 2 2
3 7 2002.80 36 14.79 2782 1481 1.81 / 314.34 2 3
4 13 1480.52 17 14.82 2217 559 2.37 / 314.90 2 4
5 13 983.08 17 14.85 1626 410 2.78 / 315.31 2 4
6 13 467.84 17 14.94 966 245 3.03 / 315.56 2 4
7 13 28.00 17 15.03 390 100 3.13 / 315.66 2 4
8 8 0.16 165 14.99 340 841 3.97 / 316.50 2 14
Average= 3.91
(KJ/cycle)

Cycle 79 GMT 7/12/2020 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.48 29 14.95 559 242 0.24 / 308.79 2 2
2 12 1325.08 2 15.14 2115 64 0.31 / 308.85 2 2
3 7 2006.68 36 14.80 2795 1489 1.80 / 310.34 2 3
4 13 1508.88 17 14.81 2257 568 2.36 / 310.91 2 4
5 13 1015.24 17 14.84 1671 422 2.79 / 311.33 2 4
6 13 524.20 17 14.93 1035 263 3.05 / 311.59 2 5
7 13 33.96 17 15.03 393 100 3.15 / 311.69 2 4
8 8 0.00 165 14.99 339 838 3.99 / 312.53 2 13
Average= 3.91
(KJ/cycle)

Cycle 78 GMT 27/11/2020 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.48 29 14.97 557 242 0.24 / 304.93 2 3
2 12 1329.48 2 15.14 2096 63 0.31 / 304.99 2 2
3 7 2005.80 36 14.79 2779 1480 1.78 / 306.47 2 3
4 13 1493.92 17 14.82 2220 559 2.34 / 307.03 2 4
5 13 1000.52 17 14.84 1636 413 2.76 / 307.44 2 4
6 13 505.12 17 14.93 1009 256 3.01 / 307.70 2 4
7 8 0.20 165 15.00 341 844 3.86 / 308.54 2 13
Average= 3.91
(KJ/cycle)

Cycle 77 GMT 18/11/2020 0:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.72 29 14.96 564 245 0.24 / 301.29 2 3
2 12 1173.96 2 15.18 1891 57 0.30 / 301.34 2 3
3 7 1908.96 36 14.81 2695 1437 1.74 / 302.78 2 3
4 13 1372.32 17 14.84 2101 530 2.27 / 303.31 2 4
5 13 872.56 17 14.89 1489 377 2.65 / 303.69 2 5
6 13 200.76 17 15.02 617 158 2.80 / 303.85 2 4
7 8 -0.08 165 15.02 339 840 3.64 / 304.69 2 13
Average= 3.91
(KJ/cycle)

Cycle 76 GMT 7/11/2020 23:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.28 29 14.96 556 241 0.24 / 297.67 2 2
2 12 1163.92 2 15.19 1872 57 0.30 / 297.73 2 3
3 7 1904.60 36 14.82 2664 1421 1.72 / 299.15 2 4
4 13 1361.36 17 14.86 2065 522 2.24 / 299.67 2 4
5 13 860.76 17 14.90 1475 374 2.61 / 300.05 2 4
6 13 193.92 17 15.02 612 156 2.77 / 300.20 2 4
7 8 0.16 165 15.02 339 840 3.61 / 301.04 2 13
Average= 3.91
(KJ/cycle)

Cycle 75 GMT 28/10/2020 23:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.92 29 14.97 561 244 0.24 / 293.73 2 3
2 7 2013.08 36 14.81 2778 1481 1.72 / 295.21 2 3
3 13 1526.20 17 14.82 2262 570 2.29 / 295.78 2 4
4 13 1052.48 17 14.84 1706 430 2.72 / 296.21 2 4
5 13 553.24 17 14.93 1077 273 3.00 / 296.49 2 4
6 13 44.40 17 15.04 407 104 3.10 / 296.59 2 4
7 8 -0.04 165 15.00 340 841 3.94 / 297.43 2 13
Average= 3.91
(KJ/cycle)

Cycle 74 GMT 19/10/2020 1:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.76 28 14.98 555 233 0.23 / 289.64 2 2
2 3 1029.64 1 15.09 1729 26 0.26 / 289.67 2 3
3 7 2002.64 36 14.82 2779 1483 1.74 / 291.15 2 3
4 13 1513.24 17 14.83 2245 566 2.31 / 291.72 2 3
5 13 1045.12 17 14.85 1699 429 2.74 / 292.14 2 4
6 13 563.36 17 14.94 1077 274 3.01 / 292.42 2 4
7 13 116.72 17 15.03 505 129 3.14 / 292.55 2 4
8 13 26.16 17 15.04 386 99 3.24 / 292.65 2 3
9 8 0.08 165 15.00 340 841 4.08 / 293.49 2 10
Average= 3.91
(KJ/cycle)

Cycle 73 GMT 9/10/2020 3:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.92 28 14.97 589 247 0.25 / 285.81 2 3
2 7 2004.60 36 14.82 2789 1488 1.73 / 287.30 2 3
3 13 1518.48 17 14.83 2266 571 2.31 / 287.87 2 4
4 13 1029.24 17 14.86 1671 422 2.73 / 288.29 2 4
5 13 542.80 17 14.95 1058 269 3.00 / 288.56 2 4
6 8 0.16 165 15.03 341 846 3.84 / 289.41 2 11
Average= 3.91
(KJ/cycle)

Cycle 72 GMT 29/ 9/2020 5:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.68 29 14.99 549 239 0.24 / 281.64 2 3
2 7 2012.48 36 14.82 2786 1486 1.73 / 283.13 2 3
3 13 1532.16 17 14.83 2277 574 2.30 / 283.70 2 4
4 13 1061.36 17 14.85 1724 435 2.73 / 284.14 2 4
5 13 568.08 17 14.94 1095 278 3.01 / 284.41 2 4
6 13 44.64 17 15.05 414 106 3.12 / 284.52 2 3
7 8 -0.12 165 15.02 348 862 3.98 / 285.38 2 13
8 14 -0.12 35 14.99 348 183 4.16 / 285.57 2 13
Average= 3.91
(KJ/cycle)

Cycle 71 GMT 19/ 9/2020 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.68 29 14.99 554 241 0.24 / 277.56 2 3
2 3 970.80 -1 15.38 7 0 0.00 / 277.56 2 3
3 3 1025.24 1 15.15 1731 26 0.27 / 277.59 2 3
4 7 2010.76 37 14.83 2782 1527 1.79 / 279.12 2 3
5 13 1518.60 17 14.84 2253 568 2.36 / 279.68 2 3
6 13 1041.96 17 14.86 1688 426 2.79 / 280.11 2 4
7 13 550.28 17 14.95 1069 272 3.06 / 280.38 2 4
8 8 0.16 165 15.04 338 839 3.90 / 281.22 2 10
9 14 0.16 35 15.01 343 180 4.08 / 281.40 3 12
Average= 3.91
(KJ/cycle)

Cycle 70 GMT 9/ 9/2020 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.16 29 15.00 572 249 0.25 / 273.50 2 2
2 3 1019.68 1 15.13 1712 26 0.27 / 273.52 2 3
3 7 2004.36 36 14.82 2789 1488 1.76 / 275.01 2 3
4 13 1521.52 17 14.83 2280 575 2.34 / 275.58 2 4
5 13 1044.92 17 14.86 1704 430 2.77 / 276.01 2 5
6 13 561.52 17 14.95 1089 277 3.04 / 276.29 2 4
7 8 0.08 165 15.04 343 851 3.90 / 277.14 2 13
8 14 0.08 35 15.01 344 181 4.08 / 277.32 2 12
Average= 3.91
(KJ/cycle)

Cycle 69 GMT 30/ 8/2020 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.72 29 14.99 557 242 0.24 / 269.64 2 2
2 7 2005.12 36 14.83 2778 1483 1.73 / 271.13 2 3
3 13 1531.32 17 14.84 2286 577 2.30 / 271.70 2 3
4 13 1054.28 17 14.87 1707 432 2.73 / 272.13 2 4
5 13 558.36 17 14.96 1082 275 3.01 / 272.41 2 4
6 8 0.04 165 15.04 337 836 3.84 / 273.25 2 12
Average= 3.90
(KJ/cycle)

Cycle 68 GMT 20/ 8/2020 13:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.76 29 15.01 555 242 0.24 / 265.63 2 3
2 7 2010.52 36 14.83 2791 1490 1.73 / 267.12 2 3
3 13 1519.52 17 14.84 2270 573 2.30 / 267.69 2 3
4 13 1043.88 17 14.87 1702 430 2.73 / 268.12 2 4
5 13 718.84 17 14.92 1292 328 3.06 / 268.45 2 4
6 13 15.72 17 15.08 371 95 3.16 / 268.54 2 4
7 8 0.16 165 15.04 346 859 4.02 / 269.40 2 12
Average= 3.90
(KJ/cycle)

Cycle 67 GMT 10/ 8/2020 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.76 29 15.02 555 242 0.24 / 261.77 2 2
2 7 2010.20 36 14.83 2798 1494 1.74 / 263.27 2 3
3 13 1508.28 17 14.84 2260 570 2.31 / 263.84 2 4
4 13 1033.48 17 14.87 1695 428 2.73 / 264.27 2 4
5 13 547.44 17 14.97 1070 272 3.01 / 264.54 2 4
6 8 -0.08 165 15.06 341 847 3.85 / 265.39 2 13
Average= 3.90
(KJ/cycle)

Cycle 66 GMT 31/ 7/2020 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.76 29 15.01 574 250 0.25 / 257.95 2 2
2 7 2003.68 36 14.84 2778 1484 1.73 / 259.43 2 3
3 13 1493.84 17 14.85 2229 563 2.30 / 259.99 2 4
4 13 1013.08 17 14.89 1670 423 2.72 / 260.42 2 4
5 13 528.68 17 14.98 1047 267 2.99 / 260.68 2 4
6 8 0.24 165 15.06 341 847 3.83 / 261.53 2 11
Average= 3.90
(KJ/cycle)

Cycle 65 GMT 21/ 7/2020 19:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.00 29 15.02 544 237 0.24 / 253.95 2 2
2 7 2010.80 36 14.83 2788 1488 1.73 / 255.44 2 3
3 13 1510.20 17 14.84 2256 569 2.29 / 256.01 2 3
4 13 1168.36 17 14.86 1856 469 2.76 / 256.48 2 4
5 13 487.88 17 14.99 988 252 3.02 / 256.73 2 4
6 13 67.44 17 15.08 444 114 3.13 / 256.84 2 4
7 8 -0.16 165 15.06 345 857 3.99 / 257.70 2 12
Average= 3.90
(KJ/cycle)

Cycle 64 GMT 11/ 7/2020 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.68 29 15.03 551 240 0.24 / 250.02 2 2
2 7 2004.52 36 14.83 2777 1483 1.72 / 251.51 2 3
3 13 1503.96 17 14.86 2228 563 2.29 / 252.07 2 3
4 13 1032.00 17 14.89 1685 427 2.71 / 252.50 2 4
5 13 538.16 17 14.98 1059 270 2.98 / 252.77 2 4
6 13 18.04 17 15.10 375 96 3.08 / 252.86 2 4
7 8 0.04 165 15.06 342 850 3.93 / 253.71 2 13
Average= 3.90
(KJ/cycle)

Cycle 63 GMT 1/ 7/2020 23:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.88 29 15.03 548 239 0.24 / 246.18 2 2
2 7 2009.92 36 14.84 2791 1491 1.73 / 247.67 2 3
3 13 1513.44 17 14.85 2251 568 2.30 / 248.24 2 3
4 13 1032.24 17 14.89 1683 426 2.72 / 248.66 2 4
5 13 543.36 17 14.99 1064 271 3.00 / 248.94 2 4
6 8 0.12 165 15.07 341 848 3.84 / 249.78 2 14
Average= 3.90
(KJ/cycle)

Cycle 62 GMT 22/ 6/2020 1:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.28 28 15.04 555 234 0.23 / 242.33 2 2
2 3 1023.84 1 15.13 1727 26 0.26 / 242.36 2 3
3 7 2005.80 36 14.84 2783 1487 1.75 / 243.84 2 3
4 13 1388.20 17 14.87 2103 532 2.28 / 244.38 2 4
5 13 1074.52 17 14.89 1740 440 2.72 / 244.82 2 4
6 13 579.00 17 14.97 1114 284 3.00 / 245.10 2 4
7 8 0.08 165 15.08 338 841 3.84 / 245.94 2 10
Average= 3.90
(KJ/cycle)

Cycle 61 GMT 12/ 6/2020 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.92 28 15.03 558 235 0.23 / 238.46 2 3
2 3 1023.60 1 15.14 1736 26 0.26 / 238.49 2 3
3 7 2013.12 36 14.84 2790 1491 1.75 / 239.98 2 3
4 13 1526.00 17 14.86 2270 573 2.33 / 240.55 2 3
5 13 1051.92 17 14.89 1706 432 2.76 / 240.98 2 4
6 13 554.16 17 14.99 1073 273 3.03 / 241.26 2 4
7 8 0.32 165 15.09 337 839 3.87 / 242.10 2 12
Average= 3.90
(KJ/cycle)

Cycle 60 GMT 2/ 6/2020 5: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.60 28 15.04 543 229 0.23 / 234.46 2 2
2 7 2011.08 37 14.84 2797 1536 1.76 / 236.00 2 3
3 13 1516.20 17 14.86 2258 570 2.33 / 236.57 2 3
4 13 1037.20 17 14.90 1689 428 2.76 / 237.00 2 4
5 13 534.80 17 15.00 1049 267 3.03 / 237.26 2 4
6 13 42.36 17 15.11 412 106 3.14 / 237.37 2 4
7 8 0.04 165 15.08 345 858 3.99 / 238.23 2 12
Average= 3.91
(KJ/cycle)

Cycle 59 GMT 23/ 5/2020 6:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.12 28 15.04 560 236 0.24 / 230.19 2 2
2 7 2008.72 37 14.85 2782 1529 1.76 / 231.72 2 3
3 13 1669.64 17 14.84 2444 617 2.38 / 232.34 2 3
4 13 1141.44 17 14.88 1816 459 2.84 / 232.80 2 4
5 13 619.60 17 14.99 1161 296 3.14 / 233.09 2 4
6 13 53.80 17 15.11 421 108 3.24 / 233.20 2 4
7 8 -0.04 165 15.09 341 849 4.09 / 234.05 2 12
8 14 -0.04 35 15.06 345 182 4.28 / 234.23 3 12
Average= 3.90
(KJ/cycle)

Cycle 58 GMT 13/ 5/2020 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.44 28 15.05 559 236 0.24 / 226.26 2 2
2 7 2004.12 36 14.86 2776 1485 1.72 / 227.75 2 3
3 13 1511.32 17 14.87 2248 568 2.29 / 228.31 2 3
4 13 1030.20 17 14.92 1665 422 2.71 / 228.74 2 4
5 13 534.48 17 15.01 1040 265 2.98 / 229.00 2 4
6 13 38.96 17 15.12 408 105 3.08 / 229.11 2 4
7 8 0.00 165 15.09 342 852 3.93 / 229.96 2 14
Average= 3.90
(KJ/cycle)

Cycle 57 GMT 3/ 5/2020 11: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.04 28 15.06 546 230 0.23 / 222.29 2 2
2 7 2008.08 36 14.86 2777 1486 1.72 / 223.78 2 3
3 13 1532.92 17 14.87 2269 574 2.29 / 224.35 2 3
4 13 1066.68 17 14.90 1732 439 2.73 / 224.79 2 4
5 13 569.00 17 15.00 1096 279 3.01 / 225.07 2 4
6 13 45.00 17 15.12 409 105 3.11 / 225.17 2 3
7 8 0.16 165 15.09 342 852 3.96 / 226.03 2 6
Average= 3.90
(KJ/cycle)

Cycle 56 GMT 23/ 4/2020 12:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.28 28 15.06 533 225 0.22 / 218.30 2 3
2 3 971.00 -1 15.44 8 0 0.00 / 218.30 2 3
3 7 2004.72 37 14.85 2792 1534 1.76 / 219.84 2 3
4 13 1512.44 17 14.87 2257 571 2.33 / 220.41 2 4
5 13 1029.76 17 14.92 1690 429 2.76 / 220.84 2 4
6 13 530.72 17 15.02 1045 267 3.02 / 221.10 2 4
7 13 36.08 17 15.13 397 102 3.13 / 221.21 2 4
8 8 0.08 165 15.10 343 855 3.98 / 222.06 2 15
Average= 3.90
(KJ/cycle)

Cycle 55 GMT 13/ 4/2020 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.40 28 15.06 569 240 0.24 / 214.17 2 2
2 7 2009.32 36 14.86 2785 1490 1.73 / 215.66 2 3
3 13 1513.80 17 14.88 2257 571 2.30 / 216.23 2 3
4 13 1031.56 17 14.92 1692 429 2.73 / 216.66 2 4
5 13 528.72 17 15.02 1048 268 3.00 / 216.92 2 4
6 13 80.64 17 15.12 466 120 3.12 / 217.04 2 3
7 8 0.20 165 15.10 343 855 3.97 / 217.90 2 15
8 14 0.20 35 15.07 344 181 4.15 / 218.08 3 12
Average= 3.89
(KJ/cycle)

Cycle 54 GMT 3/ 4/2020 16:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.96 28 15.07 563 238 0.24 / 210.19 2 3
2 7 2003.24 36 14.86 2782 1488 1.73 / 211.67 2 3
3 13 1505.76 17 14.88 2250 569 2.29 / 212.24 2 3
4 13 1027.40 17 14.93 1679 426 2.72 / 212.67 2 4
5 13 528.24 17 15.03 1044 267 2.99 / 212.94 2 4
6 13 76.88 17 15.12 466 120 3.11 / 213.06 2 4
7 8 0.00 165 15.10 349 870 3.98 / 213.93 2 13
Average= 3.89
(KJ/cycle)

Cycle 53 GMT 24/ 3/2020 19: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.44 28 15.07 555 234 0.23 / 206.21 2 3
2 7 2010.92 36 14.86 2797 1496 1.73 / 207.70 2 3
3 13 1518.64 17 14.87 2265 573 2.30 / 208.28 2 4
4 13 1041.24 17 14.93 1701 432 2.73 / 208.71 2 4
5 13 532.64 17 15.03 1056 270 3.00 / 208.98 2 4
6 13 40.76 17 15.14 415 107 3.11 / 209.08 2 3
7 8 0.08 165 15.11 347 865 3.98 / 209.95 2 10
Average= 3.89
(KJ/cycle)

Cycle 52 GMT 14/ 3/2020 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.88 28 15.07 561 237 0.24 / 202.18 2 3
2 3 1016.20 1 15.18 1714 26 0.26 / 202.21 2 3
3 7 2002.88 36 14.87 2785 1491 1.75 / 203.70 2 3
4 13 1498.24 17 14.89 2254 571 2.32 / 204.27 2 3
5 13 1165.32 17 14.90 1855 470 2.79 / 204.74 2 4
6 13 493.08 17 15.05 1003 257 3.05 / 205.00 2 4
7 13 40.60 17 15.14 413 106 3.16 / 205.10 2 3
8 8 0.16 165 15.11 348 868 4.02 / 205.97 2 10
Average= 3.89
(KJ/cycle)

Cycle 51 GMT 4/ 3/2020 23: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.72 28 15.08 548 231 0.23 / 198.22 2 3
2 3 1015.52 1 15.19 1709 26 0.26 / 198.24 2 3
3 7 2010.76 36 14.87 2788 1492 1.75 / 199.74 2 3
4 13 1512.84 17 14.89 2274 576 2.33 / 200.31 2 3
5 13 1036.12 17 14.93 1699 431 2.76 / 200.74 2 4
6 13 393.56 17 15.08 872 224 2.98 / 200.97 2 3
7 13 48.12 17 15.14 428 110 3.09 / 201.08 2 3
8 8 -0.04 165 15.12 349 871 3.96 / 201.95 2 14
Average= 3.88
(KJ/cycle)

Cycle 50 GMT 24/ 2/2020 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.92 28 15.08 553 233 0.23 / 194.22 2 3
2 7 2004.64 36 14.87 2799 1498 1.73 / 195.72 2 3
3 13 1518.44 17 14.89 2271 575 2.31 / 196.30 2 3
4 13 1032.76 17 14.94 1698 431 2.74 / 196.73 2 4
5 13 527.28 17 15.05 1055 270 3.01 / 197.00 2 4
6 13 35.92 17 15.15 409 105 3.11 / 197.10 2 3
7 8 0.28 165 15.12 354 883 4.00 / 197.99 2 11
Average= 3.88
(KJ/cycle)

Cycle 49 GMT 14/ 2/2020 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.60 28 15.09 561 237 0.24 / 190.03 2 2
2 7 2007.60 36 14.88 2785 1492 1.73 / 191.53 2 3
3 13 1526.80 17 14.89 2276 576 2.31 / 192.10 2 4
4 13 1179.84 17 14.91 1872 474 2.78 / 192.58 2 4
5 13 497.88 17 15.06 1001 256 3.04 / 192.83 2 3
6 13 38.64 17 15.16 407 105 3.14 / 192.94 2 3
7 8 0.04 165 15.13 348 869 4.01 / 193.81 2 12
8 14 0.04 35 15.10 348 184 4.19 / 193.99 3 13
Average= 3.88
(KJ/cycle)

Cycle 48 GMT 4/ 2/2020 5: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.56 28 15.09 546 231 0.23 / 185.92 2 2
2 7 2009.64 36 14.88 2798 1499 1.73 / 187.42 2 3
3 13 1665.08 17 14.88 2442 618 2.35 / 188.04 2 3
4 13 1146.68 17 14.93 1832 465 2.81 / 188.51 2 4
5 13 629.92 17 15.03 1179 301 3.11 / 188.81 2 4
6 13 59.28 17 15.16 434 112 3.23 / 188.92 2 3
7 8 0.12 165 15.13 352 879 4.10 / 189.80 2 11
Average= 3.87
(KJ/cycle)

Cycle 47 GMT 25/ 1/2020 7: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.20 28 15.09 572 242 0.24 / 181.78 2 2
2 7 2008.20 37 14.88 2782 1532 1.77 / 183.31 2 3
3 13 1514.48 17 14.90 2266 574 2.35 / 183.89 2 4
4 13 1024.72 17 14.96 1683 428 2.78 / 184.31 2 4
5 13 530.76 17 15.06 1053 270 3.04 / 184.58 2 4
6 13 96.52 17 15.15 490 126 3.17 / 184.71 2 3
7 13 56.12 17 15.15 437 113 3.28 / 184.82 2 4
8 8 -0.04 165 15.13 349 871 4.15 / 185.69 2 15
Average= 3.87
(KJ/cycle)

Cycle 46 GMT 15/ 1/2020 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.24 28 15.09 568 240 0.24 / 177.78 2 2
2 7 2002.68 36 14.87 2789 1493 1.73 / 179.28 2 3
3 13 1501.92 17 14.90 2264 573 2.31 / 179.85 2 3
4 13 1027.32 17 14.95 1693 430 2.74 / 180.28 2 3
5 13 526.72 17 15.06 1050 269 3.01 / 180.55 2 4
6 13 39.76 17 15.17 415 107 3.11 / 180.66 2 3
7 8 0.16 165 15.13 353 881 3.99 / 181.54 2 13
Average= 3.86
(KJ/cycle)

Cycle 45 GMT 5/ 1/2020 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.96 28 15.10 570 241 0.24 / 173.76 2 2
2 7 2011.16 36 14.88 2813 1507 1.75 / 175.26 2 3
3 13 1517.80 17 14.90 2279 577 2.33 / 175.84 2 3
4 13 1034.20 17 14.95 1709 434 2.76 / 176.27 2 4
5 13 532.08 17 15.07 1060 272 3.03 / 176.55 2 4
6 13 35.76 17 15.17 414 107 3.14 / 176.65 2 3
7 8 0.04 165 15.14 357 892 4.03 / 177.54 2 11
Average= 3.86
(KJ/cycle)

Cycle 44 GMT 26/12/2019 13:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.84 28 15.10 559 236 0.24 / 169.75 2 2
2 7 2002.64 36 14.89 2788 1494 1.73 / 171.25 2 3
3 13 1508.08 17 14.91 2268 575 2.31 / 171.82 2 3
4 13 1028.60 17 14.96 1702 433 2.74 / 172.26 2 4
5 13 519.96 17 15.07 1044 267 3.01 / 172.52 2 4
6 13 30.40 17 15.18 404 104 3.11 / 172.63 2 3
7 8 0.52 165 15.14 355 887 4.00 / 173.51 2 11
Average= 3.86
(KJ/cycle)

Cycle 43 GMT 16/12/2019 15:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.00 28 15.10 565 239 0.24 / 165.76 2 2
2 7 2010.88 36 14.88 2798 1499 1.74 / 167.26 2 3
3 13 1504.04 17 14.91 2255 572 2.31 / 167.83 2 4
4 13 1024.20 17 14.97 1683 428 2.74 / 168.26 2 4
5 13 526.64 17 15.07 1053 270 3.01 / 168.53 2 4
6 13 31.52 17 15.18 407 105 3.11 / 168.63 2 4
7 8 0.00 165 15.15 354 885 4.00 / 169.52 2 12
Average= 3.85
(KJ/cycle)

Cycle 42 GMT 6/12/2019 17:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.68 28 15.11 584 247 0.25 / 161.71 2 2
2 3 1018.96 1 15.19 1710 26 0.27 / 161.73 2 3
3 7 2010.44 36 14.90 2787 1495 1.77 / 163.23 2 3
4 13 1521.08 17 14.92 2277 578 2.35 / 163.81 2 3
5 13 1046.28 17 14.96 1710 435 2.78 / 164.24 2 4
6 13 541.32 17 15.07 1067 273 3.05 / 164.51 2 4
7 13 39.84 17 15.18 420 108 3.16 / 164.62 2 4
8 8 -0.04 165 15.15 359 897 4.06 / 165.52 2 14
Average= 3.85
(KJ/cycle)

Cycle 41 GMT 26/11/2019 19:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.36 27 15.11 569 232 0.23 / 157.78 2 2
2 3 1022.36 1 15.18 1718 26 0.26 / 157.81 2 3
3 7 2006.64 36 14.89 2781 1491 1.75 / 159.30 2 3
4 13 1509.48 17 14.92 2265 574 2.32 / 159.87 2 3
5 13 1021.52 17 14.97 1687 429 2.75 / 160.30 2 4
6 13 520.88 17 15.08 1044 268 3.02 / 160.57 2 4
7 8 0.28 165 15.16 357 893 3.91 / 161.46 2 10
Average= 3.84
(KJ/cycle)

Cycle 40 GMT 16/11/2019 21:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.40 27 15.11 572 233 0.23 / 153.88 2 2
2 7 2005.20 36 14.89 2794 1498 1.73 / 155.38 2 3
3 13 1508.04 17 14.92 2268 575 2.31 / 155.95 2 3
4 13 1021.64 17 14.98 1685 429 2.74 / 156.38 2 3
5 13 522.52 17 15.08 1048 269 3.00 / 156.65 2 4
6 8 0.08 165 15.16 358 896 3.90 / 157.55 2 13
Average= 3.84
(KJ/cycle)

Cycle 39 GMT 6/11/2019 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.92 28 15.11 576 244 0.24 / 149.75 2 2
2 7 2007.20 36 14.89 2791 1496 1.74 / 151.25 2 2
3 13 1510.96 16 14.93 2270 542 2.28 / 151.79 2 3
4 13 1031.16 16 14.98 1697 407 2.69 / 152.19 2 4
5 13 544.60 16 15.09 1074 259 2.95 / 152.45 2 4
6 13 43.92 16 15.20 420 102 3.05 / 152.56 2 3
7 8 0.08 165 15.16 361 903 3.95 / 153.46 2 12
8 14 0.08 35 15.13 356 189 4.14 / 153.65 2 10
Average= 3.84
(KJ/cycle)

Cycle 38 GMT 28/10/2019 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.96 28 15.12 569 241 0.24 / 145.61 2 2
2 7 2008.92 37 14.90 2781 1533 1.77 / 147.15 2 3
3 13 1501.52 16 14.94 2250 538 2.31 / 147.68 2 3
4 13 1164.80 16 14.96 1861 445 2.76 / 148.13 2 3
5 13 651.44 16 15.06 1215 293 3.05 / 148.42 2 4
6 13 62.92 16 15.19 452 110 3.16 / 148.53 2 3
7 8 0.24 180 15.16 357 974 4.13 / 149.51 2 14
Average= 3.83
(KJ/cycle)

Cycle 37 GMT 18/10/2019 3:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.28 28 15.12 585 248 0.25 / 141.89 2 2
2 12 1152.64 2 15.28 1886 58 0.31 / 141.95 2 2
3 7 1897.60 36 14.92 2679 1439 1.74 / 143.39 2 3
4 13 1370.00 16 14.97 2109 505 2.25 / 143.89 2 3
5 13 871.12 16 15.03 1504 362 2.61 / 144.26 2 4
6 13 196.40 16 15.18 625 152 2.76 / 144.41 2 3
7 8 -0.04 180 15.18 353 965 3.73 / 145.37 2 17
Average= 3.83
(KJ/cycle)

Cycle 36 GMT 8/10/2019 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.36 27 15.12 574 234 0.23 / 138.05 2 2
2 3 1031.72 1 15.19 1738 26 0.26 / 138.07 2 2
3 12 1162.96 2 15.28 1918 59 0.32 / 138.13 2 2
4 7 1908.60 36 14.91 2693 1445 1.76 / 139.58 2 3
5 13 1379.96 16 14.97 2122 508 2.27 / 140.08 2 3
6 13 877.16 16 15.04 1512 364 2.64 / 140.45 2 3
7 13 353.36 16 15.15 832 202 2.84 / 140.65 2 3
8 8 0.24 180 15.18 364 995 3.83 / 141.64 2 13
Average= 3.83
(KJ/cycle)

Cycle 35 GMT 28/ 9/2019 2:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.72 27 15.12 596 243 0.24 / 134.21 2 2
2 7 2010.60 36 14.91 2808 1507 1.75 / 135.72 2 2
3 13 1509.44 15 14.95 2267 508 2.26 / 136.23 2 3
4 13 1055.44 15 15.00 1724 388 2.65 / 136.62 2 4
5 13 568.60 15 15.10 1104 250 2.90 / 136.87 2 3
6 13 111.92 15 15.19 515 117 3.01 / 136.98 2 3
7 8 -0.16 150 15.17 364 828 3.84 / 137.81 2 11
Average= 3.83
(KJ/cycle)

Cycle 34 GMT 18/ 9/2019 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.88 27 15.13 569 232 0.23 / 130.06 2 2
2 7 2002.84 36 14.91 2792 1499 1.73 / 131.56 2 2
3 13 1497.28 15 14.94 2260 506 2.24 / 132.07 2 3
4 13 1166.76 15 14.97 1869 420 2.66 / 132.49 2 3
5 13 665.88 15 15.08 1234 279 2.94 / 132.77 2 4
6 13 72.88 15 15.20 466 106 3.04 / 132.87 2 3
7 8 0.36 170 15.17 361 931 3.97 / 133.81 2 10
8 14 0.36 30 15.15 360 164 4.14 / 133.97 2 14
Average= 3.83
(KJ/cycle)

Cycle 33 GMT 8/ 9/2019 6: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.64 27 15.13 587 240 0.24 / 126.13 2 2
2 7 2004.76 36 14.91 2801 1503 1.74 / 127.64 2 2
3 13 1503.76 15 14.96 2262 508 2.25 / 128.14 2 3
4 13 1040.36 15 15.01 1705 384 2.63 / 128.53 2 4
5 13 574.56 15 15.10 1110 251 2.89 / 128.78 2 3
6 13 114.80 15 15.20 518 118 3.00 / 128.90 2 3
7 8 0.16 170 15.18 362 934 3.94 / 129.83 2 10
Average= 3.82
(KJ/cycle)

Cycle 32 GMT 29/ 8/2019 7:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.80 27 15.14 586 240 0.24 / 121.99 2 2
2 3 1015.56 1 15.22 1720 26 0.27 / 122.02 2 2
3 7 2011.28 36 14.91 2813 1510 1.78 / 123.53 2 2
4 13 1511.88 15 14.95 2277 511 2.29 / 124.04 2 3
5 13 1038.72 15 15.01 1710 385 2.67 / 124.42 2 4
6 13 565.20 15 15.11 1100 249 2.92 / 124.67 2 4
7 13 122.16 15 15.20 529 121 3.04 / 124.79 2 3
8 8 -0.08 170 15.18 362 934 3.98 / 125.73 2 15
9 14 -0.08 30 15.15 362 165 4.14 / 125.89 2 13
Average= 3.81
(KJ/cycle)

Cycle 31 GMT 19/ 8/2019 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.40 27 15.13 581 237 0.24 / 118.06 2 2
2 7 2007.52 36 14.92 2810 1509 1.75 / 119.57 2 2
3 13 1507.20 15 14.95 2283 512 2.26 / 120.08 2 3
4 13 1033.56 15 15.01 1705 384 2.64 / 120.46 2 3
5 13 562.44 15 15.11 1099 249 2.89 / 120.71 2 4
6 13 53.00 15 15.22 442 101 2.99 / 120.81 2 3
7 8 0.16 170 15.18 365 942 3.93 / 121.75 2 15
Average= 3.80
(KJ/cycle)

Cycle 30 GMT 9/ 8/2019 11:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.20 27 15.14 586 240 0.24 / 113.93 2 2
2 3 1038.28 1 15.18 1748 27 0.27 / 113.96 2 3
3 7 2007.04 36 14.92 2799 1503 1.77 / 115.46 2 2
4 13 1500.96 15 14.96 2252 505 2.27 / 115.97 2 3
5 13 1026.80 15 15.02 1694 382 2.66 / 116.35 2 3
6 13 554.08 15 15.11 1098 249 2.91 / 116.60 2 4
7 13 118.44 15 15.20 524 119 3.02 / 116.72 2 3
8 8 0.12 170 15.19 363 937 3.96 / 117.65 2 12
9 14 0.12 30 15.16 362 165 4.13 / 117.82 2 12
Average= 3.80
(KJ/cycle)

Cycle 29 GMT 30/ 7/2019 12:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.00 27 15.13 580 237 0.24 / 109.86 2 2
2 3 975.48 -1 15.47 7 0 0.00 / 109.86 2 2
3 3 1029.28 1 15.20 1744 27 0.26 / 109.89 2 3
4 7 2006.88 37 14.92 2806 1549 1.81 / 111.44 2 2
5 13 1497.72 15 14.96 2257 506 2.32 / 111.94 2 3
6 13 1166.32 15 15.00 1870 421 2.74 / 112.36 2 4
7 13 665.44 15 15.09 1240 281 3.02 / 112.64 2 4
8 13 33.68 15 15.23 417 95 3.12 / 112.74 2 3
9 8 0.00 170 15.19 369 953 4.07 / 113.69 2 14
Average= 3.79
(KJ/cycle)

Cycle 28 GMT 20/ 7/2019 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.96 27 15.14 594 243 0.24 / 105.71 2 2
2 7 2005.56 36 14.92 2793 1500 1.74 / 107.21 2 2
3 13 1489.36 15 14.97 2257 507 2.25 / 107.72 2 3
4 13 1016.76 15 15.02 1689 381 2.63 / 108.10 2 3
5 13 689.52 15 15.08 1277 289 2.92 / 108.39 2 4
6 13 96.32 15 15.21 505 115 3.03 / 108.50 2 4
7 8 0.16 175 15.18 369 980 4.01 / 109.48 2 13
8 14 0.16 25 15.16 369 140 4.15 / 109.62 3 10
Average= 3.78
(KJ/cycle)

Cycle 27 GMT 10/ 7/2019 16:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.80 27 15.15 588 241 0.24 / 101.51 2 3
2 7 2003.44 36 14.92 2809 1509 1.75 / 103.01 2 2
3 13 1486.76 15 14.97 2247 505 2.25 / 103.52 2 3
4 13 1152.60 15 15.00 1860 418 2.67 / 103.94 2 3
5 13 640.96 15 15.09 1219 276 2.95 / 104.21 2 4
6 13 146.28 15 15.20 576 131 3.08 / 104.34 2 3
7 8 0.32 175 15.19 370 984 4.06 / 105.33 2 14
8 14 0.32 25 15.16 371 141 4.20 / 105.47 3 15
Average= 3.77
(KJ/cycle)

Cycle 26 GMT 30/ 6/2019 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.32 27 15.14 597 244 0.24 / 97.33 2 2
2 7 2005.60 36 14.93 2798 1504 1.75 / 98.83 2 2
3 13 1517.16 15 14.97 2282 512 2.26 / 99.34 2 3
4 13 1053.56 15 15.02 1729 390 2.65 / 99.73 2 3
5 13 729.48 15 15.08 1328 300 2.95 / 100.03 2 4
6 13 105.52 15 15.22 515 118 3.07 / 100.15 2 3
7 8 0.16 175 15.19 367 976 4.04 / 101.13 2 13
8 14 0.16 25 15.17 367 139 4.18 / 101.27 3 16
Average= 3.75
(KJ/cycle)

Cycle 25 GMT 20/ 6/2019 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.92 27 15.15 589 241 0.24 / 93.09 2 2
2 7 2009.96 36 14.93 2802 1506 1.75 / 94.60 2 2
3 13 1511.80 15 14.98 2275 511 2.26 / 95.11 2 3
4 13 1046.44 15 15.03 1730 390 2.65 / 95.50 2 4
5 13 560.24 15 15.13 1110 252 2.90 / 95.75 2 3
6 13 110.52 15 15.22 524 120 3.02 / 95.87 2 3
7 13 24.44 15 15.23 407 93 3.11 / 95.96 2 3
8 8 0.08 175 15.19 369 981 4.09 / 96.94 2 13
9 14 0.08 25 15.16 367 139 4.23 / 97.08 2 15
Average= 3.73
(KJ/cycle)

Cycle 24 GMT 10/ 6/2019 21:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.28 27 15.17 540 221 0.22 / 89.04 2 2
2 7 2004.00 36 14.94 2794 1503 1.72 / 90.55 2 2
3 13 1494.92 15 14.98 2239 503 2.23 / 91.05 2 3
4 13 1167.80 15 15.01 1870 421 2.65 / 91.47 2 3
5 13 664.68 15 15.10 1245 282 2.93 / 91.75 2 4
6 13 80.68 15 15.23 481 110 3.04 / 91.86 2 3
7 8 0.28 175 15.20 371 987 4.03 / 92.85 2 10
Average= 3.71
(KJ/cycle)

Cycle 23 GMT 31/ 5/2019 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.60 27 15.17 552 226 0.23 / 85.14 2 2
2 7 2002.80 36 14.94 2780 1495 1.72 / 86.64 2 2
3 13 1491.00 15 14.99 2230 501 2.22 / 87.14 2 3
4 13 1167.36 15 15.02 1844 415 2.64 / 87.55 2 3
5 13 669.80 15 15.10 1226 278 2.92 / 87.83 2 4
6 13 82.64 15 15.24 459 105 3.02 / 87.94 2 3
7 8 0.08 175 15.22 333 887 3.91 / 88.82 2 9
Average= 3.70
(KJ/cycle)

Cycle 22 GMT 22/ 5/2019 1:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.88 27 15.18 536 220 0.22 / 81.32 2 2
2 7 2005.40 36 14.94 2773 1491 1.71 / 82.81 2 2
3 13 1499.76 15 14.99 2236 503 2.21 / 83.31 2 3
4 13 1026.76 15 15.05 1672 377 2.59 / 83.69 2 3
5 13 548.32 15 15.14 1064 242 2.83 / 83.93 2 4
6 13 102.96 15 15.23 482 110 2.94 / 84.04 2 3
7 8 0.00 175 15.22 328 874 3.82 / 84.92 2 11
Average= 3.69
(KJ/cycle)

Cycle 21 GMT 12/ 5/2019 3:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.60 27 15.18 542 222 0.22 / 77.50 2 2
2 7 2009.44 36 14.94 2791 1501 1.72 / 79.00 2 2
3 13 1515.68 15 14.99 2260 508 2.23 / 79.51 2 3
4 13 1034.80 15 15.05 1677 379 2.61 / 79.89 2 3
5 13 553.72 15 15.14 1065 242 2.85 / 80.13 2 3
6 13 52.64 15 15.25 412 94 2.95 / 80.23 2 3
7 8 0.16 175 15.22 328 874 3.82 / 81.10 2 10
Average= 3.69
(KJ/cycle)

Cycle 20 GMT 2/ 5/2019 5:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.40 27 15.19 523 214 0.21 / 73.70 2 2
2 7 2003.24 36 14.95 2779 1496 1.71 / 75.19 2 2
3 13 1494.88 15 15.00 2229 502 2.21 / 75.69 2 3
4 13 1021.32 15 15.06 1665 376 2.59 / 76.07 2 3
5 13 541.36 15 15.15 1051 239 2.83 / 76.31 2 3
6 13 51.76 15 15.25 412 94 2.92 / 76.40 2 3
7 8 0.16 175 15.23 329 877 3.80 / 77.28 2 10
Average= 3.68
(KJ/cycle)

Cycle 19 GMT 22/ 4/2019 7: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.36 27 15.19 535 219 0.22 / 69.90 2 2
2 7 2005.72 36 14.95 2780 1496 1.72 / 71.39 2 2
3 13 1491.88 15 15.00 2229 502 2.22 / 71.89 2 3
4 13 1030.92 15 15.06 1677 379 2.60 / 72.27 2 3
5 13 699.96 15 15.11 1257 285 2.88 / 72.56 2 4
6 13 85.92 15 15.25 456 104 2.99 / 72.66 2 3
7 8 0.12 165 15.23 326 819 3.80 / 73.48 2 11
Average= 3.67
(KJ/cycle)

Cycle 18 GMT 12/ 4/2019 9: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.32 27 15.20 528 217 0.22 / 65.95 2 2
2 7 2003.16 36 14.96 2780 1497 1.71 / 67.45 2 2
3 13 1492.60 15 15.01 2232 503 2.22 / 67.95 2 3
4 13 1023.00 15 15.06 1666 376 2.59 / 68.33 2 3
5 13 546.24 15 15.15 1058 240 2.83 / 68.57 2 3
6 13 98.28 15 15.25 473 108 2.94 / 68.68 2 3
7 8 -0.08 165 15.23 328 824 3.77 / 69.50 2 11
8 14 -0.08 35 15.21 329 175 3.94 / 69.68 2 7
Average= 3.67
(KJ/cycle)

Cycle 17 GMT 2/ 4/2019 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.12 27 15.20 536 220 0.22 / 62.20 2 2
2 7 2002.48 36 14.96 2768 1491 1.71 / 63.69 2 2
3 13 1481.84 15 15.02 2212 498 2.21 / 64.19 2 3
4 13 1023.12 15 15.06 1669 377 2.59 / 64.57 2 3
5 13 549.24 15 15.16 1057 240 2.83 / 64.81 2 3
6 13 96.44 15 15.26 469 107 2.93 / 64.91 2 3
7 8 0.04 165 15.24 327 822 3.76 / 65.74 2 11
Average= 3.65
(KJ/cycle)

Cycle 16 GMT 23/ 3/2019 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.40 27 15.20 541 222 0.22 / 58.32 2 3
2 3 1026.92 1 15.25 1735 26 0.25 / 58.34 2 2
3 7 2004.48 36 14.97 2779 1498 1.75 / 59.84 2 2
4 13 1510.16 17 15.01 2240 572 2.32 / 60.41 2 3
5 13 1025.20 17 15.06 1666 427 2.74 / 60.84 2 3
6 13 376.36 17 15.20 833 215 2.96 / 61.06 2 3
7 13 45.96 17 15.26 402 104 3.06 / 61.16 2 3
8 8 0.36 165 15.24 326 820 3.88 / 61.98 2 11
Average= 3.65
(KJ/cycle)

Cycle 15 GMT 13/ 3/2019 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.44 27 15.19 551 226 0.23 / 54.44 2 2
2 7 2005.16 36 14.97 2773 1494 1.72 / 55.93 2 2
3 13 1502.20 17 15.01 2219 566 2.29 / 56.50 2 3
4 13 1010.12 17 15.07 1642 421 2.71 / 56.92 2 3
5 13 494.76 17 15.17 985 254 2.96 / 57.17 2 3
6 13 31.00 17 15.27 383 99 3.06 / 57.27 2 3
7 8 -0.08 165 15.24 327 822 3.88 / 58.10 2 13
Average= 3.63
(KJ/cycle)

Cycle 14 GMT 3/ 3/2019 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.48 27 15.19 546 224 0.22 / 50.51 2 2
2 7 2004.16 38 14.96 2770 1575 1.80 / 52.09 2 2
3 13 1454.16 17 15.02 2176 556 2.35 / 52.64 2 3
4 13 947.68 17 15.08 1568 402 2.76 / 53.05 2 3
5 13 423.68 17 15.19 893 231 2.99 / 53.28 2 3
6 13 45.84 17 15.26 405 105 3.09 / 53.38 2 3
7 8 0.36 165 15.24 331 832 3.92 / 54.21 2 9
Average= 3.61
(KJ/cycle)

Cycle 13 GMT 21/ 2/2019 18:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.88 27 15.20 539 221 0.22 / 46.45 2 2
2 7 2007.64 38 14.96 2772 1576 1.80 / 48.03 2 2
3 13 1349.00 17 15.04 2051 524 2.32 / 48.55 2 3
4 13 1022.96 17 15.06 1662 426 2.75 / 48.98 2 3
5 13 337.32 17 15.21 789 204 2.95 / 49.18 2 3
6 13 34.00 17 15.27 393 102 3.05 / 49.28 2 4
7 8 0.12 165 15.24 331 832 3.89 / 50.11 2 11
8 14 0.12 35 15.21 330 176 4.06 / 50.29 3 11
Average= 3.59
(KJ/cycle)

Cycle 12 GMT 11/ 2/2019 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.92 27 15.21 541 222 0.22 / 42.49 2 2
2 7 2008.04 38 14.97 2778 1580 1.80 / 44.07 2 2
3 13 1470.60 17 15.02 2195 560 2.36 / 44.63 2 3
4 13 970.24 17 15.08 1602 411 2.77 / 45.04 2 3
5 13 452.16 17 15.18 943 243 3.02 / 45.29 2 4
6 13 28.00 17 15.27 386 100 3.12 / 45.39 2 3
7 8 -0.04 165 15.24 335 842 3.96 / 46.23 2 14
Average= 3.56
(KJ/cycle)

Cycle 11 GMT 1/ 2/2019 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.32 27 15.21 533 219 0.22 / 38.79 2 2
2 7 2003.72 38 14.96 2776 1578 1.80 / 40.37 2 2
3 13 1337.68 17 15.04 2039 521 2.32 / 40.89 2 3
4 13 864.96 17 15.10 1466 376 2.69 / 41.27 2 4
5 13 227.44 17 15.24 643 167 2.86 / 41.44 2 3
6 8 0.08 165 15.25 331 833 3.69 / 42.27 2 12
Average= 3.52
(KJ/cycle)

Cycle 10 GMT 23/ 1/2019 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.48 27 15.21 544 223 0.22 / 34.97 2 2
2 7 2007.12 38 14.97 2768 1575 1.80 / 36.54 2 2
3 13 1468.88 17 15.03 2188 559 2.36 / 37.10 2 3
4 13 966.80 17 15.09 1595 409 2.77 / 37.51 2 4
5 13 432.24 17 15.19 911 235 3.00 / 37.74 2 4
6 8 0.20 165 15.25 330 830 3.83 / 38.57 2 10
Average= 3.51
(KJ/cycle)

Cycle 9 GMT 13/ 1/2019 1:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.36 27 15.21 542 223 0.22 / 31.15 2 2
2 7 2005.24 38 14.98 2766 1575 1.80 / 32.73 2 2
3 13 1481.48 17 15.03 2206 564 2.36 / 33.29 2 3
4 13 976.96 17 15.09 1609 413 2.77 / 33.70 2 4
5 13 324.48 17 15.22 772 200 2.97 / 33.90 2 3
6 8 0.00 165 15.26 334 841 3.81 / 34.74 2 13
Average= 3.47
(KJ/cycle)

Cycle 8 GMT 3/ 1/2019 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.32 28 15.21 539 230 0.23 / 27.42 2 2
2 7 2009.32 38 14.98 2775 1580 1.81 / 29.00 2 2
3 13 1495.16 17 15.03 2225 569 2.38 / 29.57 2 3
4 13 829.40 17 15.12 1419 365 2.74 / 29.93 2 3
5 13 195.16 17 15.26 600 156 2.90 / 30.09 2 3
6 8 0.28 165 15.26 333 838 3.74 / 30.93 2 9
Average= 3.44
(KJ/cycle)

Cycle 7 GMT 24/12/2018 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.48 23 15.22 558 195 0.20 / 23.54 2 2
2 10 1040.36 3 15.19 1708 78 0.27 / 23.62 2 2
3 3 1053.68 2 15.24 1764 54 0.33 / 23.67 2 2
4 7 2006.12 38 14.98 2764 1573 1.90 / 25.24 2 2
5 13 1340.00 17 15.06 2043 523 2.42 / 25.77 2 3
6 13 863.04 17 15.11 1468 377 2.80 / 26.14 2 4
7 13 371.52 17 15.21 828 214 3.01 / 26.36 2 3
8 8 0.12 165 15.26 331 833 3.85 / 27.19 2 9
Average= 3.40
(KJ/cycle)

Cycle 6 GMT 14/12/2018 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 11 15.23 471 79 0.08 / 19.38 2 2
2 10 1021.36 7 15.16 1677 178 0.26 / 19.56 2 2
3 10 1075.40 4 15.16 1734 105 0.36 / 19.67 2 2
4 10 1110.16 2 15.15 1792 54 0.42 / 19.72 2 2
5 3 1072.08 2 15.21 1783 54 0.47 / 19.78 2 3
6 7 2005.28 38 14.98 2769 1576 2.05 / 21.35 2 2
7 13 1347.72 18 15.05 2046 554 2.60 / 21.91 2 3
8 13 862.80 18 15.11 1464 398 3.00 / 22.30 2 4
9 13 335.16 18 15.22 779 213 3.21 / 22.52 2 3
10 8 0.08 165 15.26 328 826 4.04 / 23.34 2 12
Average= 3.33
(KJ/cycle)

Cycle 5 GMT 4/12/2018 9:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 31 15.23 478 226 0.23 / 15.74 2 2
2 3 599.64 -8 15.55 8 0 0.00 / 15.74 2 2
3 3 755.08 -5 15.57 8 0 0.00 / 15.74 2 2
4 7 2002.24 38 15.00 2762 1574 1.80 / 17.31 2 2
5 13 1460.68 18 15.05 2174 589 2.39 / 17.90 2 3
6 13 808.88 18 15.13 1384 377 2.77 / 18.28 2 4
7 13 299.72 18 15.24 736 202 2.97 / 18.48 2 3
8 8 0.08 165 15.26 327 823 3.79 / 19.31 2 11
Average= 3.22
(KJ/cycle)

Cycle 4 GMT 24/11/2018 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 17 15.25 473 123 0.12 / 12.23 2 2
2 10 1050.20 3 15.22 1715 78 0.20 / 12.31 2 2
3 3 1044.92 1 15.25 1751 27 0.23 / 12.34 2 2
4 7 1509.64 38 15.11 2194 1260 1.49 / 13.60 2 2
5 13 1366.36 18 15.10 2046 556 2.04 / 14.15 2 3
6 13 847.64 18 15.15 1428 389 2.43 / 14.54 2 3
7 13 151.28 18 15.29 537 148 2.58 / 14.69 2 3
8 8 0.12 165 15.28 327 824 3.41 / 15.51 2 11
Average= 3.10
(KJ/cycle)

Cycle 3 GMT 23/11/2018 11:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 28 15.24 473 202 0.20 / 8.74 2 3
2 3 722.16 -5 15.54 8 0 0.00 / 8.74 2 3
3 3 866.12 -3 15.56 8 0 0.00 / 8.74 2 3
4 7 1518.72 74 15.03 2179 2424 2.63 / 11.16 2 3
5 13 145.24 18 15.29 526 145 2.77 / 11.30 2 3
6 8 0.12 165 15.28 319 804 3.57 / 12.11 2 8
Average= 3.03
(KJ/cycle)

Cycle 2 GMT 22/11/2018 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 29 15.25 482 213 0.21 / 5.14 2 2
2 3 936.24 -1 15.55 8 0 0.00 / 5.14 2 2
3 7 1524.84 74 15.03 2187 2432 2.65 / 7.58 2 3
4 13 152.28 18 15.29 534 147 2.79 / 7.72 2 3
5 8 0.16 165 15.28 322 812 3.60 / 8.53 2 13
Average= 2.84
(KJ/cycle)

Cycle 1 GMT 21/11/2018 11:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 29 15.42 421 188 0.19 / 1.99 2 3
2 3 951.68 -1 15.56 7 0 0.00 / 1.99 2 3
3 7 1002.28 74 15.18 1571 1765 1.95 / 3.75 2 3
4 8 -0.04 240 15.31 321 1179 3.13 / 4.93 2 14
Average= 2.47
(KJ/cycle)

Cycle 0 GMT 21/11/2018 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 149.68 28 15.56 486 212 0.21 / 0.21 2 3
2 7 163.24 74 15.52 485 557 0.77 / 0.77 3 3
3 8 0.08 240 15.48 277 1029 1.80 / 1.80 2 9
Average= 1.80
(KJ/cycle)