SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 29 | 15.15 | 490 | 215 | 0.22 / 660.57 | 2 | 2 |
2 | 7 | 1436.12 | 30 | 15.14 | 2460 | 1117 | 1.33 / 661.69 | 2 | 3 |
3 | 13 | 1348.60 | 25 | 15.06 | 2326 | 876 | 2.21 / 662.57 | 2 | 4 |
4 | 13 | 774.80 | 25 | 15.10 | 1505 | 568 | 2.78 / 663.14 | 2 | 5 |
5 | 8 | 0.16 | 170 | 15.21 | 304 | 786 | 3.56 / 663.92 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 29 | 15.15 | 487 | 214 | 0.21 / 657.05 | 2 | 3 |
2 | 7 | 1392.40 | 29 | 15.15 | 2402 | 1055 | 1.27 / 658.11 | 2 | 3 |
3 | 13 | 1355.96 | 25 | 15.04 | 2341 | 880 | 2.15 / 658.99 | 2 | 6 |
4 | 13 | 792.68 | 25 | 15.10 | 1533 | 579 | 2.73 / 659.57 | 2 | 3 |
5 | 8 | 0.24 | 170 | 15.21 | 306 | 791 | 3.52 / 660.36 | 2 | 8 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 29 | 15.13 | 488 | 214 | 0.21 / 653.58 | 2 | 3 |
2 | 7 | 1401.08 | 29 | 15.15 | 2405 | 1057 | 1.27 / 654.64 | 2 | 4 |
3 | 13 | 1325.40 | 25 | 15.07 | 2297 | 865 | 2.14 / 655.50 | 2 | 4 |
4 | 13 | 753.84 | 25 | 15.12 | 1476 | 558 | 2.69 / 656.06 | 2 | 5 |
5 | 8 | 0.04 | 170 | 15.21 | 302 | 781 | 3.47 / 656.84 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 29 | 15.12 | 485 | 213 | 0.21 / 649.99 | 2 | 3 |
2 | 7 | 1489.68 | 29 | 15.12 | 2530 | 1109 | 1.32 / 651.09 | 2 | 3 |
3 | 13 | 1395.92 | 25 | 15.04 | 2398 | 902 | 2.22 / 652.00 | 2 | 3 |
4 | 13 | 812.84 | 25 | 15.09 | 1559 | 588 | 2.81 / 652.58 | 2 | 4 |
5 | 8 | 0.04 | 170 | 15.21 | 302 | 781 | 3.59 / 653.37 | 2 | 8 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 29 | 15.13 | 495 | 217 | 0.22 / 645.97 | 2 | 2 |
2 | 7 | 1658.84 | 29 | 15.06 | 2774 | 1212 | 1.43 / 647.19 | 2 | 4 |
3 | 13 | 1542.88 | 25 | 14.98 | 2598 | 973 | 2.40 / 648.16 | 2 | 5 |
4 | 13 | 813.20 | 25 | 15.06 | 1560 | 587 | 2.99 / 648.75 | 2 | 4 |
5 | 13 | 25.56 | 25 | 15.22 | 353 | 134 | 3.12 / 648.88 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.19 | 301 | 777 | 3.90 / 649.66 | 2 | 5 |
7 | 14 | 0.04 | 25 | 15.17 | 303 | 115 | 4.02 / 649.77 | 2 | 8 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 29 | 15.14 | 498 | 219 | 0.22 / 642.06 | 2 | 2 |
2 | 7 | 1584.12 | 29 | 15.09 | 2668 | 1168 | 1.39 / 643.23 | 2 | 3 |
3 | 13 | 1477.60 | 25 | 15.00 | 2510 | 941 | 2.33 / 644.17 | 2 | 4 |
4 | 13 | 1003.52 | 25 | 15.03 | 1838 | 691 | 3.02 / 644.86 | 2 | 3 |
5 | 8 | 0.04 | 170 | 15.20 | 302 | 780 | 3.80 / 645.64 | 2 | 7 |
6 | 14 | 0.04 | 25 | 15.18 | 302 | 115 | 3.91 / 645.76 | 3 | 3 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 29 | 15.12 | 492 | 216 | 0.22 / 638.36 | 2 | 2 |
2 | 7 | 1560.60 | 29 | 15.10 | 2627 | 1150 | 1.37 / 639.51 | 2 | 5 |
3 | 13 | 1453.64 | 25 | 15.01 | 2476 | 929 | 2.30 / 640.44 | 2 | 3 |
4 | 13 | 878.12 | 25 | 15.07 | 1656 | 624 | 2.92 / 641.06 | 2 | 3 |
5 | 8 | 0.08 | 170 | 15.20 | 302 | 780 | 3.70 / 641.84 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 29 | 15.14 | 477 | 209 | 0.21 / 634.59 | 2 | 3 |
2 | 7 | 1608.76 | 29 | 15.08 | 2705 | 1183 | 1.39 / 635.77 | 2 | 4 |
3 | 13 | 1496.44 | 25 | 14.99 | 2540 | 952 | 2.34 / 636.72 | 2 | 3 |
4 | 13 | 901.48 | 25 | 15.05 | 1688 | 635 | 2.98 / 637.36 | 2 | 5 |
5 | 8 | 0.20 | 170 | 15.20 | 305 | 788 | 3.77 / 638.14 | 2 | 5 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 29 | 15.17 | 492 | 216 | 0.22 / 630.92 | 2 | 3 |
2 | 7 | 1538.04 | 29 | 15.12 | 2601 | 1140 | 1.36 / 632.06 | 2 | 3 |
3 | 13 | 1438.52 | 25 | 15.04 | 2461 | 925 | 2.28 / 632.98 | 2 | 5 |
4 | 13 | 844.12 | 25 | 15.09 | 1610 | 607 | 2.89 / 633.59 | 2 | 5 |
5 | 8 | 0.00 | 170 | 15.20 | 305 | 788 | 3.68 / 634.38 | 2 | 4 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 29 | 15.16 | 490 | 215 | 0.22 / 627.48 | 2 | 2 |
2 | 7 | 1386.24 | 29 | 15.17 | 2379 | 1047 | 1.26 / 628.53 | 2 | 3 |
3 | 13 | 1308.72 | 25 | 15.09 | 2265 | 854 | 2.12 / 629.38 | 2 | 3 |
4 | 13 | 712.88 | 25 | 15.15 | 1413 | 535 | 2.65 / 629.91 | 2 | 6 |
5 | 8 | 0.20 | 170 | 15.23 | 303 | 784 | 3.44 / 630.70 | 2 | 5 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 29 | 15.16 | 490 | 215 | 0.22 / 624.04 | 2 | 3 |
2 | 7 | 1318.52 | 29 | 15.20 | 2294 | 1011 | 1.23 / 625.05 | 2 | 3 |
3 | 13 | 1252.08 | 25 | 15.11 | 2187 | 826 | 2.05 / 625.88 | 2 | 3 |
4 | 13 | 824.00 | 25 | 15.13 | 1570 | 594 | 2.65 / 626.47 | 2 | 5 |
5 | 8 | 0.24 | 170 | 15.23 | 305 | 790 | 3.44 / 627.26 | 2 | 5 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 29 | 15.16 | 484 | 213 | 0.21 / 620.56 | 2 | 3 |
2 | 7 | 1411.12 | 29 | 15.16 | 2418 | 1063 | 1.28 / 621.62 | 2 | 3 |
3 | 13 | 1323.68 | 25 | 15.08 | 2291 | 864 | 2.14 / 622.49 | 2 | 4 |
4 | 13 | 748.56 | 25 | 15.13 | 1463 | 553 | 2.69 / 623.04 | 2 | 4 |
5 | 8 | 0.08 | 170 | 15.22 | 304 | 787 | 3.48 / 623.83 | 2 | 8 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 29 | 15.14 | 495 | 217 | 0.22 / 616.83 | 2 | 2 |
2 | 7 | 1587.84 | 29 | 15.13 | 2675 | 1174 | 1.39 / 618.01 | 2 | 3 |
3 | 13 | 1477.00 | 25 | 15.04 | 2506 | 942 | 2.33 / 618.95 | 2 | 3 |
4 | 13 | 868.68 | 25 | 15.10 | 1638 | 618 | 2.95 / 619.57 | 2 | 4 |
5 | 8 | 0.48 | 170 | 15.22 | 302 | 781 | 3.73 / 620.35 | 2 | 6 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 29 | 15.14 | 476 | 209 | 0.21 / 612.87 | 2 | 2 |
2 | 7 | 1788.12 | 29 | 15.05 | 2955 | 1290 | 1.50 / 614.16 | 2 | 3 |
3 | 13 | 1662.76 | 25 | 14.96 | 2789 | 1043 | 2.54 / 615.21 | 2 | 5 |
4 | 13 | 889.20 | 25 | 15.04 | 1672 | 629 | 3.17 / 615.83 | 2 | 4 |
5 | 8 | -0.20 | 170 | 15.20 | 302 | 780 | 3.95 / 616.61 | 2 | 8 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 29 | 15.16 | 493 | 217 | 0.22 / 608.97 | 2 | 2 |
2 | 7 | 1761.16 | 29 | 15.04 | 2922 | 1274 | 1.49 / 610.24 | 2 | 3 |
3 | 13 | 1636.28 | 25 | 14.95 | 2740 | 1024 | 2.52 / 611.26 | 2 | 3 |
4 | 13 | 878.72 | 25 | 15.04 | 1658 | 623 | 3.14 / 611.89 | 2 | 4 |
5 | 8 | 0.16 | 170 | 15.20 | 300 | 775 | 3.91 / 612.66 | 2 | 8 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 29 | 15.15 | 478 | 210 | 0.21 / 605.31 | 2 | 3 |
2 | 7 | 1572.92 | 29 | 15.13 | 2649 | 1162 | 1.37 / 606.47 | 2 | 3 |
3 | 13 | 1472.12 | 25 | 15.04 | 2500 | 940 | 2.31 / 607.41 | 2 | 3 |
4 | 13 | 749.00 | 25 | 15.11 | 1468 | 555 | 2.87 / 607.97 | 2 | 4 |
5 | 8 | 0.44 | 170 | 15.22 | 303 | 784 | 3.65 / 608.75 | 2 | 5 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 29 | 15.17 | 493 | 217 | 0.22 / 601.61 | 2 | 3 |
2 | 7 | 1474.92 | 29 | 15.15 | 2516 | 1105 | 1.32 / 602.72 | 2 | 5 |
3 | 13 | 1378.32 | 25 | 15.07 | 2371 | 893 | 2.22 / 603.61 | 2 | 4 |
4 | 13 | 813.44 | 25 | 15.11 | 1560 | 589 | 2.80 / 604.20 | 2 | 4 |
5 | 8 | 0.00 | 170 | 15.22 | 302 | 781 | 3.59 / 604.98 | 2 | 9 |
6 | 14 | 0.00 | 25 | 15.20 | 302 | 115 | 3.70 / 605.10 | 2 | 19 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 29 | 15.15 | 485 | 213 | 0.21 / 598.07 | 2 | 3 |
2 | 7 | 1396.76 | 29 | 15.18 | 2398 | 1056 | 1.27 / 599.13 | 2 | 3 |
3 | 13 | 1317.80 | 25 | 15.08 | 2287 | 862 | 2.13 / 599.99 | 2 | 3 |
4 | 13 | 856.68 | 25 | 15.12 | 1626 | 615 | 2.75 / 600.61 | 2 | 4 |
5 | 8 | 0.12 | 170 | 15.24 | 306 | 793 | 3.54 / 601.40 | 2 | 5 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 29 | 15.18 | 486 | 214 | 0.21 / 594.40 | 2 | 3 |
2 | 7 | 1382.08 | 29 | 15.17 | 2386 | 1050 | 1.26 / 595.45 | 2 | 3 |
3 | 13 | 1301.76 | 25 | 15.09 | 2257 | 851 | 2.12 / 596.30 | 2 | 3 |
4 | 13 | 855.60 | 25 | 15.11 | 1623 | 613 | 2.73 / 596.92 | 2 | 5 |
5 | 13 | 73.44 | 25 | 15.25 | 432 | 165 | 2.89 / 597.08 | 2 | 4 |
6 | 8 | 0.08 | 170 | 15.22 | 301 | 779 | 3.67 / 597.86 | 2 | 5 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 29 | 15.17 | 501 | 220 | 0.22 / 590.96 | 2 | 3 |
2 | 7 | 1372.56 | 29 | 15.19 | 2370 | 1044 | 1.26 / 592.00 | 2 | 3 |
3 | 13 | 1294.96 | 25 | 15.11 | 2256 | 852 | 2.12 / 592.85 | 2 | 4 |
4 | 13 | 724.00 | 25 | 15.16 | 1432 | 543 | 2.66 / 593.40 | 2 | 4 |
5 | 8 | 0.00 | 170 | 15.24 | 305 | 790 | 3.45 / 594.19 | 2 | 4 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 29 | 15.12 | 489 | 214 | 0.21 / 587.29 | 2 | 3 |
2 | 3 | 1022.88 | 1 | 15.28 | 1926 | 29 | 0.24 / 587.32 | 2 | 3 |
3 | 7 | 1415.12 | 29 | 15.19 | 2423 | 1067 | 1.31 / 588.39 | 2 | 4 |
4 | 13 | 1327.96 | 25 | 15.11 | 2304 | 870 | 2.18 / 589.26 | 2 | 5 |
5 | 13 | 748.36 | 25 | 15.16 | 1469 | 557 | 2.74 / 589.82 | 2 | 5 |
6 | 13 | 18.52 | 25 | 15.29 | 341 | 130 | 2.87 / 589.95 | 2 | 4 |
7 | 8 | 0.12 | 170 | 15.24 | 305 | 790 | 3.66 / 590.74 | 2 | 6 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 29 | 15.13 | 488 | 214 | 0.21 / 583.17 | 2 | 3 |
2 | 7 | 1975.16 | 29 | 14.98 | 3218 | 1398 | 1.61 / 584.57 | 2 | 3 |
3 | 13 | 1572.12 | 25 | 14.94 | 2650 | 990 | 2.60 / 585.56 | 2 | 5 |
4 | 13 | 839.92 | 25 | 15.03 | 1600 | 601 | 3.20 / 586.16 | 2 | 6 |
5 | 13 | 40.80 | 25 | 15.21 | 378 | 144 | 3.35 / 586.30 | 2 | 6 |
6 | 8 | 0.20 | 170 | 15.18 | 302 | 779 | 4.13 / 587.08 | 2 | 9 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 29 | 15.13 | 470 | 206 | 0.21 / 578.88 | 2 | 2 |
2 | 7 | 2002.60 | 29 | 15.00 | 3241 | 1410 | 1.62 / 580.29 | 2 | 4 |
3 | 13 | 1746.60 | 25 | 14.92 | 2888 | 1077 | 2.69 / 581.36 | 2 | 5 |
4 | 13 | 947.28 | 25 | 15.01 | 1757 | 659 | 3.35 / 582.02 | 2 | 3 |
5 | 13 | 65.88 | 25 | 15.21 | 423 | 161 | 3.51 / 582.18 | 2 | 2 |
6 | 8 | 0.16 | 170 | 15.18 | 298 | 769 | 4.28 / 582.95 | 2 | 10 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 29 | 15.12 | 477 | 209 | 0.21 / 574.70 | 2 | 3 |
2 | 7 | 2009.04 | 29 | 14.98 | 3256 | 1414 | 1.62 / 576.11 | 2 | 3 |
3 | 13 | 1615.68 | 25 | 14.93 | 2709 | 1011 | 2.63 / 577.12 | 2 | 3 |
4 | 13 | 878.92 | 25 | 15.03 | 1660 | 624 | 3.26 / 577.75 | 2 | 3 |
5 | 13 | 54.72 | 25 | 15.21 | 405 | 154 | 3.41 / 577.90 | 2 | 5 |
6 | 8 | -0.08 | 170 | 15.18 | 299 | 772 | 4.18 / 578.67 | 2 | 7 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 29 | 15.12 | 499 | 219 | 0.22 / 570.43 | 2 | 3 |
2 | 7 | 2014.12 | 29 | 14.97 | 3258 | 1414 | 1.63 / 571.85 | 2 | 5 |
3 | 13 | 1623.28 | 25 | 14.92 | 2713 | 1012 | 2.65 / 572.86 | 2 | 3 |
4 | 13 | 996.76 | 25 | 14.99 | 1826 | 684 | 3.33 / 573.54 | 2 | 3 |
5 | 13 | 68.32 | 25 | 15.19 | 428 | 163 | 3.49 / 573.71 | 2 | 8 |
6 | 8 | 0.00 | 170 | 15.17 | 303 | 781 | 4.27 / 574.49 | 2 | 11 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 29 | 15.13 | 481 | 211 | 0.21 / 566.14 | 2 | 3 |
2 | 7 | 2011.52 | 30 | 14.98 | 3255 | 1463 | 1.67 / 567.60 | 2 | 3 |
3 | 13 | 1602.28 | 25 | 14.93 | 2686 | 1003 | 2.68 / 568.60 | 2 | 3 |
4 | 13 | 977.08 | 25 | 15.00 | 1798 | 674 | 3.35 / 569.28 | 2 | 4 |
5 | 13 | 71.72 | 25 | 15.21 | 429 | 163 | 3.51 / 569.44 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.18 | 299 | 772 | 4.29 / 570.21 | 2 | 6 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 29 | 15.13 | 491 | 215 | 0.22 / 561.95 | 2 | 3 |
2 | 7 | 2003.08 | 29 | 14.99 | 3246 | 1411 | 1.63 / 563.36 | 2 | 5 |
3 | 13 | 1728.92 | 25 | 14.92 | 2868 | 1070 | 2.70 / 564.43 | 2 | 3 |
4 | 13 | 831.68 | 25 | 15.03 | 1589 | 597 | 3.29 / 565.02 | 2 | 3 |
5 | 13 | 46.36 | 25 | 15.21 | 382 | 145 | 3.44 / 565.17 | 2 | 3 |
6 | 8 | 0.20 | 170 | 15.18 | 294 | 759 | 4.20 / 565.93 | 2 | 6 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 29 | 15.14 | 471 | 207 | 0.21 / 557.64 | 2 | 3 |
2 | 7 | 2002.88 | 29 | 14.99 | 3257 | 1416 | 1.62 / 559.06 | 2 | 4 |
3 | 13 | 1746.92 | 25 | 14.91 | 2900 | 1081 | 2.70 / 560.14 | 2 | 3 |
4 | 13 | 961.52 | 25 | 15.01 | 1779 | 668 | 3.37 / 560.81 | 2 | 3 |
5 | 13 | 57.08 | 25 | 15.21 | 403 | 153 | 3.52 / 560.96 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.19 | 298 | 770 | 4.29 / 561.73 | 2 | 8 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 29 | 15.13 | 480 | 211 | 0.21 / 553.43 | 2 | 3 |
2 | 7 | 2012.20 | 29 | 15.00 | 3256 | 1416 | 1.63 / 554.84 | 2 | 7 |
3 | 13 | 1603.76 | 25 | 14.95 | 2688 | 1005 | 2.63 / 555.85 | 2 | 4 |
4 | 13 | 980.04 | 25 | 14.99 | 1804 | 676 | 3.31 / 556.52 | 2 | 3 |
5 | 13 | 31.92 | 25 | 15.21 | 364 | 138 | 3.45 / 556.66 | 2 | 2 |
6 | 8 | 0.00 | 170 | 15.19 | 300 | 775 | 4.22 / 557.44 | 2 | 5 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 29 | 15.13 | 489 | 215 | 0.21 / 549.09 | 2 | 3 |
2 | 7 | 2011.00 | 29 | 14.99 | 3252 | 1414 | 1.63 / 550.51 | 2 | 3 |
3 | 13 | 1722.96 | 25 | 14.92 | 2854 | 1065 | 2.69 / 551.57 | 2 | 3 |
4 | 13 | 960.72 | 25 | 15.01 | 1776 | 666 | 3.36 / 552.24 | 2 | 3 |
5 | 13 | 129.20 | 25 | 15.20 | 525 | 199 | 3.56 / 552.44 | 2 | 3 |
6 | 8 | 0.20 | 170 | 15.19 | 301 | 777 | 4.34 / 553.22 | 2 | 8 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 29 | 15.13 | 487 | 214 | 0.21 / 544.90 | 2 | 2 |
2 | 7 | 2009.28 | 29 | 14.99 | 3255 | 1415 | 1.63 / 546.32 | 2 | 3 |
3 | 13 | 1609.24 | 25 | 14.93 | 2703 | 1009 | 2.64 / 547.33 | 2 | 3 |
4 | 13 | 875.88 | 25 | 15.03 | 1658 | 623 | 3.26 / 547.95 | 2 | 4 |
5 | 13 | 50.44 | 25 | 15.23 | 396 | 151 | 3.41 / 548.10 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.20 | 301 | 778 | 4.19 / 548.88 | 2 | 5 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 29 | 15.15 | 474 | 208 | 0.21 / 540.74 | 2 | 2 |
2 | 7 | 2003.68 | 29 | 14.99 | 3251 | 1413 | 1.62 / 542.15 | 2 | 3 |
3 | 13 | 1610.72 | 25 | 14.93 | 2696 | 1006 | 2.63 / 543.16 | 2 | 3 |
4 | 13 | 870.12 | 25 | 15.02 | 1646 | 618 | 3.25 / 543.78 | 2 | 5 |
5 | 13 | 28.00 | 25 | 15.22 | 361 | 137 | 3.38 / 543.92 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.19 | 300 | 775 | 4.16 / 544.69 | 2 | 6 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 29 | 15.14 | 478 | 210 | 0.21 / 536.46 | 2 | 3 |
2 | 7 | 2003.36 | 29 | 15.03 | 3254 | 1418 | 1.63 / 537.87 | 2 | 6 |
3 | 13 | 1721.80 | 25 | 14.94 | 2865 | 1070 | 2.70 / 538.94 | 2 | 3 |
4 | 13 | 942.12 | 25 | 15.04 | 1758 | 661 | 3.36 / 539.61 | 2 | 4 |
5 | 13 | 58.20 | 25 | 15.24 | 413 | 157 | 3.52 / 539.76 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.20 | 298 | 770 | 4.29 / 540.53 | 2 | 5 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 29 | 15.14 | 486 | 213 | 0.21 / 532.26 | 2 | 3 |
2 | 7 | 2008.76 | 29 | 15.02 | 3258 | 1419 | 1.63 / 533.68 | 2 | 5 |
3 | 13 | 1615.72 | 25 | 14.95 | 2713 | 1014 | 2.65 / 534.69 | 2 | 3 |
4 | 13 | 877.64 | 25 | 15.05 | 1656 | 623 | 3.27 / 535.31 | 2 | 3 |
5 | 13 | 54.44 | 25 | 15.24 | 404 | 154 | 3.42 / 535.47 | 2 | 3 |
6 | 8 | 0.24 | 170 | 15.21 | 301 | 778 | 4.20 / 536.25 | 2 | 8 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 29 | 15.16 | 493 | 217 | 0.22 / 528.07 | 2 | 3 |
2 | 7 | 2006.20 | 29 | 15.01 | 3248 | 1414 | 1.63 / 529.48 | 2 | 5 |
3 | 13 | 1618.40 | 25 | 14.94 | 2714 | 1014 | 2.64 / 530.49 | 2 | 3 |
4 | 13 | 880.24 | 25 | 15.04 | 1657 | 623 | 3.27 / 531.12 | 2 | 4 |
5 | 13 | 53.84 | 25 | 15.23 | 402 | 153 | 3.42 / 531.27 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.20 | 300 | 775 | 4.20 / 532.04 | 2 | 7 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 29 | 15.16 | 488 | 215 | 0.21 / 523.89 | 2 | 2 |
2 | 7 | 2007.36 | 29 | 15.01 | 3252 | 1416 | 1.63 / 525.31 | 2 | 5 |
3 | 13 | 1605.68 | 25 | 14.96 | 2698 | 1009 | 2.64 / 526.31 | 2 | 3 |
4 | 13 | 861.08 | 25 | 15.06 | 1634 | 615 | 3.25 / 526.93 | 2 | 3 |
5 | 13 | 46.68 | 25 | 15.24 | 390 | 149 | 3.40 / 527.08 | 2 | 5 |
6 | 8 | 0.16 | 170 | 15.21 | 298 | 771 | 4.17 / 527.85 | 2 | 5 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 29 | 15.16 | 484 | 213 | 0.21 / 519.60 | 2 | 2 |
2 | 7 | 2005.04 | 29 | 15.02 | 3260 | 1420 | 1.63 / 521.02 | 2 | 2 |
3 | 13 | 1731.12 | 25 | 14.96 | 2877 | 1076 | 2.71 / 522.10 | 2 | 3 |
4 | 13 | 947.04 | 25 | 15.04 | 1765 | 664 | 3.37 / 522.76 | 2 | 4 |
5 | 13 | 31.76 | 25 | 15.24 | 363 | 138 | 3.51 / 522.90 | 2 | 4 |
6 | 8 | -0.08 | 170 | 15.21 | 301 | 778 | 4.29 / 523.68 | 2 | 7 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 29 | 15.17 | 476 | 209 | 0.21 / 515.33 | 2 | 3 |
2 | 7 | 2007.48 | 29 | 15.02 | 3254 | 1417 | 1.63 / 516.75 | 2 | 5 |
3 | 13 | 1726.80 | 25 | 14.94 | 2878 | 1075 | 2.70 / 517.82 | 2 | 4 |
4 | 13 | 931.56 | 25 | 15.05 | 1738 | 654 | 3.36 / 518.48 | 2 | 4 |
5 | 13 | 26.88 | 25 | 15.24 | 355 | 135 | 3.49 / 518.61 | 2 | 2 |
6 | 8 | 0.20 | 170 | 15.21 | 300 | 776 | 4.27 / 519.39 | 2 | 8 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 29 | 15.16 | 486 | 214 | 0.21 / 511.06 | 2 | 3 |
2 | 7 | 2002.68 | 29 | 15.02 | 3237 | 1410 | 1.62 / 512.47 | 2 | 2 |
3 | 13 | 1610.28 | 25 | 14.96 | 2708 | 1013 | 2.64 / 513.48 | 2 | 4 |
4 | 13 | 859.68 | 25 | 15.05 | 1630 | 613 | 3.25 / 514.10 | 2 | 5 |
5 | 13 | 23.56 | 25 | 15.26 | 348 | 133 | 3.38 / 514.23 | 2 | 2 |
6 | 8 | 0.08 | 170 | 15.22 | 300 | 776 | 4.16 / 515.01 | 2 | 6 |
7 | 14 | 0.08 | 25 | 15.20 | 299 | 114 | 4.27 / 515.12 | 3 | 8 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 28 | 15.16 | 491 | 208 | 0.21 / 506.78 | 2 | 3 |
2 | 7 | 2010.40 | 29 | 15.02 | 3259 | 1420 | 1.63 / 508.20 | 2 | 4 |
3 | 13 | 1602.20 | 25 | 14.96 | 2698 | 1009 | 2.64 / 509.21 | 2 | 5 |
4 | 13 | 862.36 | 25 | 15.06 | 1637 | 616 | 3.25 / 509.82 | 2 | 4 |
5 | 13 | 22.88 | 25 | 15.25 | 349 | 133 | 3.39 / 509.95 | 2 | 3 |
6 | 8 | -0.04 | 170 | 15.22 | 301 | 779 | 4.17 / 510.73 | 2 | 12 |
7 | 14 | -0.04 | 25 | 15.19 | 301 | 114 | 4.28 / 510.85 | 2 | 10 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 28 | 15.17 | 491 | 209 | 0.21 / 502.53 | 2 | 3 |
2 | 7 | 2004.56 | 29 | 15.02 | 3253 | 1417 | 1.63 / 503.95 | 2 | 4 |
3 | 13 | 1606.96 | 25 | 14.96 | 2708 | 1013 | 2.64 / 504.96 | 2 | 3 |
4 | 13 | 995.68 | 25 | 15.02 | 1834 | 689 | 3.33 / 505.65 | 2 | 4 |
5 | 13 | 35.40 | 25 | 15.25 | 373 | 142 | 3.47 / 505.79 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.21 | 300 | 776 | 4.24 / 506.57 | 2 | 5 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 28 | 15.17 | 488 | 207 | 0.21 / 498.37 | 2 | 2 |
2 | 7 | 2009.12 | 29 | 15.01 | 3242 | 1411 | 1.62 / 499.78 | 2 | 3 |
3 | 13 | 1595.56 | 25 | 14.98 | 2687 | 1006 | 2.62 / 500.79 | 2 | 3 |
4 | 13 | 845.28 | 25 | 15.07 | 1616 | 609 | 3.23 / 501.40 | 2 | 4 |
5 | 13 | 20.52 | 25 | 15.26 | 346 | 132 | 3.37 / 501.53 | 2 | 4 |
6 | 8 | 0.00 | 170 | 15.22 | 306 | 792 | 4.16 / 502.32 | 2 | 4 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 28 | 15.16 | 493 | 209 | 0.21 / 494.20 | 2 | 3 |
2 | 7 | 2008.08 | 29 | 15.02 | 3262 | 1421 | 1.63 / 495.62 | 2 | 3 |
3 | 13 | 1603.28 | 25 | 14.97 | 2702 | 1011 | 2.64 / 496.63 | 2 | 4 |
4 | 13 | 851.68 | 25 | 15.07 | 1626 | 613 | 3.25 / 497.24 | 2 | 4 |
5 | 13 | 40.84 | 25 | 15.25 | 380 | 145 | 3.40 / 497.39 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.22 | 301 | 779 | 4.18 / 498.17 | 2 | 11 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 28 | 15.17 | 500 | 212 | 0.21 / 489.95 | 2 | 2 |
2 | 7 | 2010.24 | 29 | 15.01 | 3262 | 1420 | 1.63 / 491.37 | 2 | 3 |
3 | 13 | 1616.88 | 25 | 14.96 | 2715 | 1015 | 2.65 / 492.39 | 2 | 3 |
4 | 13 | 979.56 | 25 | 15.04 | 1812 | 681 | 3.33 / 493.07 | 2 | 3 |
5 | 13 | 29.44 | 25 | 15.26 | 363 | 138 | 3.47 / 493.21 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.22 | 301 | 779 | 4.25 / 493.99 | 2 | 5 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 29 | 15.16 | 493 | 217 | 0.22 / 485.95 | 2 | 3 |
2 | 7 | 2007.84 | 29 | 15.01 | 3256 | 1417 | 1.63 / 487.37 | 2 | 5 |
3 | 13 | 1491.12 | 25 | 14.98 | 2537 | 950 | 2.58 / 488.32 | 2 | 3 |
4 | 13 | 898.08 | 25 | 15.04 | 1687 | 634 | 3.22 / 488.95 | 2 | 5 |
5 | 8 | 0.16 | 170 | 15.23 | 304 | 787 | 4.01 / 489.74 | 2 | 8 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 29 | 15.15 | 482 | 212 | 0.21 / 481.78 | 2 | 3 |
2 | 7 | 2004.40 | 29 | 15.01 | 3261 | 1419 | 1.63 / 483.20 | 2 | 5 |
3 | 13 | 1612.88 | 25 | 14.94 | 2708 | 1011 | 2.64 / 484.21 | 2 | 3 |
4 | 13 | 855.72 | 25 | 15.06 | 1633 | 615 | 3.26 / 484.82 | 2 | 3 |
5 | 13 | 21.36 | 25 | 15.25 | 344 | 131 | 3.39 / 484.96 | 2 | 3 |
6 | 8 | -0.04 | 170 | 15.21 | 302 | 781 | 4.17 / 485.74 | 2 | 9 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 29 | 15.17 | 502 | 221 | 0.22 / 477.60 | 2 | 3 |
2 | 7 | 2005.80 | 29 | 15.03 | 3262 | 1422 | 1.64 / 479.02 | 2 | 3 |
3 | 13 | 1593.48 | 25 | 14.97 | 2680 | 1003 | 2.65 / 480.02 | 2 | 3 |
4 | 13 | 847.04 | 25 | 15.06 | 1620 | 610 | 3.26 / 480.63 | 2 | 4 |
5 | 13 | 42.00 | 25 | 15.24 | 384 | 146 | 3.40 / 480.78 | 2 | 4 |
6 | 8 | 0.16 | 170 | 15.22 | 304 | 787 | 4.19 / 481.57 | 2 | 6 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 29 | 15.18 | 492 | 217 | 0.22 / 473.55 | 2 | 5 |
2 | 7 | 2006.16 | 29 | 15.01 | 3255 | 1417 | 1.63 / 474.97 | 2 | 4 |
3 | 13 | 1597.40 | 25 | 14.96 | 2689 | 1006 | 2.64 / 475.98 | 2 | 6 |
4 | 13 | 856.80 | 25 | 15.05 | 1630 | 613 | 3.25 / 476.59 | 2 | 6 |
5 | 8 | 0.12 | 170 | 15.23 | 305 | 790 | 4.04 / 477.38 | 2 | 8 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 29 | 15.15 | 491 | 216 | 0.22 / 469.52 | 2 | 3 |
2 | 7 | 2006.84 | 29 | 15.03 | 3255 | 1419 | 1.63 / 470.94 | 2 | 6 |
3 | 13 | 1591.48 | 25 | 14.97 | 2680 | 1003 | 2.64 / 471.94 | 2 | 3 |
4 | 13 | 846.72 | 25 | 15.06 | 1617 | 609 | 3.25 / 472.55 | 2 | 4 |
5 | 8 | 0.04 | 170 | 15.23 | 304 | 787 | 4.03 / 473.34 | 2 | 4 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 29 | 15.17 | 509 | 224 | 0.22 / 465.25 | 2 | 2 |
2 | 7 | 2009.32 | 29 | 15.01 | 3255 | 1417 | 1.64 / 466.67 | 2 | 5 |
3 | 13 | 1609.28 | 25 | 14.96 | 2705 | 1012 | 2.65 / 467.68 | 2 | 4 |
4 | 13 | 980.12 | 25 | 15.03 | 1810 | 680 | 3.33 / 468.36 | 2 | 3 |
5 | 13 | 60.32 | 25 | 15.23 | 420 | 160 | 3.49 / 468.52 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.21 | 304 | 786 | 4.28 / 469.30 | 2 | 3 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 29 | 15.16 | 488 | 215 | 0.21 / 461.19 | 2 | 3 |
2 | 7 | 2008.16 | 29 | 15.02 | 3265 | 1422 | 1.64 / 462.61 | 2 | 5 |
3 | 13 | 1601.48 | 25 | 14.97 | 2698 | 1010 | 2.65 / 463.62 | 2 | 4 |
4 | 13 | 858.48 | 25 | 15.07 | 1640 | 618 | 3.26 / 464.24 | 2 | 4 |
5 | 8 | 0.36 | 170 | 15.23 | 304 | 787 | 4.05 / 465.02 | 2 | 15 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 29 | 15.16 | 490 | 215 | 0.22 / 457.00 | 2 | 19 |
2 | 7 | 2005.12 | 29 | 15.01 | 3248 | 1414 | 1.63 / 458.42 | 2 | 7 |
3 | 13 | 1591.88 | 25 | 14.96 | 2674 | 1000 | 2.63 / 459.42 | 2 | 3 |
4 | 13 | 849.84 | 25 | 15.06 | 1618 | 609 | 3.24 / 460.03 | 2 | 6 |
5 | 13 | 88.20 | 25 | 15.23 | 458 | 174 | 3.41 / 460.20 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.22 | 298 | 771 | 4.18 / 460.97 | 2 | 11 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 29 | 15.15 | 493 | 217 | 0.22 / 452.84 | 2 | 5 |
2 | 7 | 2002.88 | 29 | 15.02 | 3245 | 1413 | 1.63 / 454.25 | 2 | 3 |
3 | 13 | 1594.28 | 25 | 14.97 | 2685 | 1005 | 2.63 / 455.26 | 2 | 3 |
4 | 13 | 853.00 | 25 | 15.07 | 1628 | 613 | 3.25 / 455.87 | 2 | 4 |
5 | 13 | 39.56 | 25 | 15.25 | 375 | 143 | 3.39 / 456.02 | 2 | 2 |
6 | 8 | -0.20 | 170 | 15.22 | 299 | 774 | 4.16 / 456.79 | 2 | 2 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 29 | 15.15 | 494 | 217 | 0.22 / 448.67 | 2 | 3 |
2 | 7 | 2003.56 | 29 | 15.01 | 3250 | 1415 | 1.63 / 450.09 | 2 | 6 |
3 | 13 | 1607.08 | 25 | 14.97 | 2693 | 1008 | 2.64 / 451.10 | 2 | 4 |
4 | 13 | 867.72 | 25 | 15.05 | 1640 | 617 | 3.26 / 451.71 | 2 | 4 |
5 | 13 | 49.40 | 25 | 15.24 | 390 | 149 | 3.41 / 451.86 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.21 | 295 | 763 | 4.17 / 452.62 | 2 | 5 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 29 | 15.15 | 497 | 218 | 0.22 / 444.50 | 2 | 3 |
2 | 7 | 2010.12 | 29 | 15.02 | 3265 | 1422 | 1.64 / 445.92 | 2 | 5 |
3 | 13 | 1615.72 | 25 | 14.96 | 2708 | 1013 | 2.65 / 446.93 | 2 | 8 |
4 | 13 | 860.44 | 25 | 15.06 | 1632 | 614 | 3.27 / 447.55 | 2 | 5 |
5 | 13 | 41.52 | 25 | 15.24 | 376 | 143 | 3.41 / 447.69 | 2 | 3 |
6 | 8 | 0.36 | 170 | 15.21 | 296 | 765 | 4.18 / 448.46 | 2 | 6 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 29 | 15.17 | 474 | 209 | 0.21 / 440.32 | 2 | 3 |
2 | 7 | 2007.76 | 29 | 15.05 | 3254 | 1420 | 1.63 / 441.74 | 2 | 3 |
3 | 13 | 1610.16 | 25 | 14.97 | 2696 | 1009 | 2.64 / 442.74 | 2 | 5 |
4 | 13 | 871.00 | 25 | 15.06 | 1647 | 620 | 3.26 / 443.36 | 2 | 3 |
5 | 13 | 49.12 | 25 | 15.25 | 392 | 149 | 3.41 / 443.51 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.21 | 296 | 765 | 4.17 / 444.28 | 2 | 4 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 29 | 15.16 | 476 | 209 | 0.21 / 436.03 | 2 | 3 |
2 | 7 | 2002.72 | 30 | 15.04 | 3253 | 1468 | 1.68 / 437.50 | 2 | 3 |
3 | 13 | 1723.28 | 25 | 14.96 | 2861 | 1070 | 2.75 / 438.57 | 2 | 5 |
4 | 13 | 941.28 | 25 | 15.05 | 1753 | 660 | 3.41 / 439.23 | 2 | 4 |
5 | 8 | 0.24 | 170 | 15.22 | 297 | 768 | 4.18 / 439.99 | 2 | 5 |
6 | 14 | 0.24 | 25 | 15.20 | 298 | 113 | 4.29 / 440.11 | 2 | 4 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 29 | 15.16 | 491 | 216 | 0.22 / 431.80 | 2 | 3 |
2 | 7 | 2007.40 | 29 | 15.03 | 3254 | 1418 | 1.63 / 433.22 | 2 | 5 |
3 | 13 | 1608.12 | 25 | 14.98 | 2700 | 1011 | 2.65 / 434.23 | 2 | 4 |
4 | 13 | 986.84 | 25 | 15.04 | 1818 | 684 | 3.33 / 434.91 | 2 | 4 |
5 | 13 | 38.92 | 25 | 15.25 | 372 | 142 | 3.47 / 435.06 | 2 | 3 |
6 | 8 | -0.04 | 170 | 15.22 | 295 | 763 | 4.23 / 435.82 | 2 | 8 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 29 | 15.15 | 480 | 211 | 0.21 / 427.57 | 2 | 3 |
2 | 7 | 2009.32 | 29 | 15.03 | 3256 | 1419 | 1.63 / 428.99 | 2 | 4 |
3 | 13 | 1742.16 | 25 | 14.95 | 2881 | 1077 | 2.71 / 430.07 | 2 | 3 |
4 | 13 | 824.52 | 25 | 15.08 | 1581 | 596 | 3.30 / 430.67 | 2 | 3 |
5 | 13 | 53.40 | 25 | 15.25 | 399 | 152 | 3.46 / 430.82 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.22 | 296 | 766 | 4.22 / 431.58 | 2 | 4 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 29 | 15.16 | 479 | 211 | 0.21 / 423.28 | 2 | 3 |
2 | 7 | 2005.88 | 29 | 15.02 | 3261 | 1420 | 1.63 / 424.70 | 2 | 3 |
3 | 13 | 1738.92 | 25 | 14.94 | 2883 | 1077 | 2.71 / 425.78 | 2 | 5 |
4 | 13 | 941.28 | 25 | 15.05 | 1754 | 660 | 3.37 / 426.44 | 2 | 4 |
5 | 13 | 64.24 | 25 | 15.24 | 422 | 161 | 3.53 / 426.60 | 2 | 3 |
6 | 8 | 0.40 | 170 | 15.21 | 297 | 768 | 4.30 / 427.36 | 2 | 9 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 29 | 15.15 | 481 | 211 | 0.21 / 419.00 | 2 | 3 |
2 | 7 | 2003.76 | 29 | 15.03 | 3235 | 1410 | 1.62 / 420.41 | 2 | 3 |
3 | 13 | 1733.12 | 25 | 14.96 | 2872 | 1074 | 2.70 / 421.48 | 2 | 7 |
4 | 13 | 945.56 | 25 | 15.05 | 1755 | 660 | 3.36 / 422.14 | 2 | 3 |
5 | 13 | 59.96 | 25 | 15.25 | 410 | 156 | 3.51 / 422.30 | 2 | 3 |
6 | 8 | -0.16 | 170 | 15.22 | 297 | 768 | 4.28 / 423.07 | 2 | 10 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 29 | 15.16 | 469 | 206 | 0.21 / 414.71 | 2 | 2 |
2 | 7 | 2004.04 | 29 | 15.03 | 3257 | 1420 | 1.63 / 416.13 | 2 | 5 |
3 | 13 | 1609.08 | 25 | 14.98 | 2685 | 1006 | 2.63 / 417.13 | 2 | 5 |
4 | 13 | 866.48 | 25 | 15.07 | 1645 | 620 | 3.25 / 417.75 | 2 | 4 |
5 | 13 | 50.64 | 25 | 15.25 | 394 | 150 | 3.40 / 417.90 | 2 | 3 |
6 | 8 | 0.32 | 170 | 15.22 | 298 | 771 | 4.17 / 418.67 | 2 | 10 |
7 | 14 | 0.32 | 25 | 15.20 | 297 | 113 | 4.29 / 418.79 | 3 | 7 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 29 | 15.15 | 489 | 215 | 0.21 / 410.54 | 2 | 3 |
2 | 7 | 2002.60 | 29 | 15.03 | 3248 | 1416 | 1.63 / 411.95 | 2 | 4 |
3 | 13 | 1611.20 | 25 | 14.98 | 2707 | 1014 | 2.64 / 412.97 | 2 | 6 |
4 | 13 | 865.48 | 25 | 15.07 | 1638 | 617 | 3.26 / 413.58 | 2 | 6 |
5 | 13 | 49.76 | 25 | 15.25 | 391 | 149 | 3.41 / 413.73 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.22 | 297 | 768 | 4.18 / 414.50 | 2 | 7 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 29 | 15.16 | 486 | 214 | 0.21 / 406.26 | 2 | 2 |
2 | 7 | 2008.56 | 29 | 15.03 | 3258 | 1420 | 1.63 / 407.68 | 2 | 3 |
3 | 13 | 1607.92 | 25 | 14.97 | 2697 | 1009 | 2.64 / 408.69 | 2 | 5 |
4 | 13 | 994.52 | 25 | 15.03 | 1826 | 686 | 3.33 / 409.38 | 2 | 4 |
5 | 13 | 79.00 | 25 | 15.24 | 445 | 170 | 3.50 / 409.55 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.22 | 300 | 776 | 4.27 / 410.32 | 2 | 11 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 29 | 15.16 | 491 | 216 | 0.22 / 402.08 | 2 | 2 |
2 | 7 | 2005.68 | 29 | 15.02 | 3255 | 1418 | 1.63 / 403.50 | 2 | 3 |
3 | 13 | 1600.48 | 25 | 14.98 | 2692 | 1008 | 2.64 / 404.51 | 2 | 5 |
4 | 13 | 859.24 | 25 | 15.07 | 1632 | 615 | 3.26 / 405.12 | 2 | 4 |
5 | 13 | 49.92 | 25 | 15.25 | 396 | 151 | 3.41 / 405.27 | 2 | 3 |
6 | 8 | -0.04 | 170 | 15.22 | 300 | 776 | 4.18 / 406.05 | 2 | 9 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 29 | 15.16 | 487 | 214 | 0.21 / 397.76 | 2 | 3 |
2 | 7 | 2009.12 | 29 | 15.05 | 3258 | 1422 | 1.64 / 399.19 | 2 | 4 |
3 | 13 | 1736.08 | 25 | 14.98 | 2882 | 1079 | 2.72 / 400.27 | 2 | 3 |
4 | 13 | 936.84 | 25 | 15.06 | 1740 | 655 | 3.37 / 400.92 | 2 | 3 |
5 | 13 | 64.44 | 25 | 15.26 | 422 | 161 | 3.53 / 401.08 | 2 | 4 |
6 | 8 | 0.12 | 170 | 15.24 | 302 | 782 | 4.31 / 401.86 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 29 | 15.16 | 487 | 214 | 0.21 / 393.46 | 2 | 2 |
2 | 7 | 2004.32 | 29 | 15.04 | 3252 | 1418 | 1.63 / 394.88 | 2 | 5 |
3 | 13 | 1725.96 | 25 | 14.97 | 2864 | 1072 | 2.70 / 395.95 | 2 | 7 |
4 | 13 | 946.76 | 25 | 15.05 | 1753 | 660 | 3.36 / 396.61 | 2 | 5 |
5 | 13 | 64.52 | 25 | 15.25 | 420 | 160 | 3.52 / 396.77 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.21 | 301 | 778 | 4.30 / 397.55 | 2 | 7 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 29 | 15.16 | 482 | 212 | 0.21 / 389.31 | 2 | 2 |
2 | 7 | 2010.28 | 29 | 15.02 | 3245 | 1413 | 1.63 / 390.72 | 2 | 3 |
3 | 13 | 1502.08 | 25 | 14.99 | 2550 | 956 | 2.58 / 391.68 | 2 | 4 |
4 | 13 | 916.20 | 25 | 15.06 | 1712 | 645 | 3.23 / 392.32 | 2 | 3 |
5 | 13 | 53.20 | 25 | 15.25 | 396 | 151 | 3.38 / 392.47 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.21 | 300 | 776 | 4.15 / 393.25 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 29 | 15.17 | 484 | 213 | 0.21 / 385.14 | 2 | 3 |
2 | 7 | 2005.48 | 29 | 15.04 | 3249 | 1417 | 1.63 / 386.56 | 2 | 5 |
3 | 13 | 1603.56 | 25 | 14.99 | 2692 | 1009 | 2.64 / 387.57 | 2 | 3 |
4 | 13 | 845.00 | 25 | 15.09 | 1608 | 607 | 3.25 / 388.17 | 2 | 5 |
5 | 13 | 42.52 | 25 | 15.26 | 384 | 146 | 3.39 / 388.32 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.23 | 299 | 774 | 4.17 / 389.10 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 28 | 15.18 | 485 | 206 | 0.21 / 380.85 | 2 | 2 |
2 | 7 | 2003.04 | 29 | 15.03 | 3249 | 1416 | 1.62 / 382.26 | 2 | 4 |
3 | 13 | 1733.68 | 25 | 14.96 | 2869 | 1073 | 2.70 / 383.34 | 2 | 7 |
4 | 13 | 946.16 | 25 | 15.06 | 1758 | 662 | 3.36 / 384.00 | 2 | 3 |
5 | 13 | 61.20 | 25 | 15.25 | 413 | 157 | 3.51 / 384.16 | 2 | 3 |
6 | 8 | -0.08 | 170 | 15.23 | 299 | 774 | 4.29 / 384.93 | 2 | 8 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 28 | 15.19 | 497 | 211 | 0.21 / 376.61 | 2 | 2 |
2 | 7 | 2012.20 | 29 | 15.04 | 3258 | 1421 | 1.63 / 378.03 | 2 | 6 |
3 | 13 | 1742.48 | 25 | 14.96 | 2888 | 1080 | 2.71 / 379.11 | 2 | 6 |
4 | 13 | 844.76 | 25 | 15.09 | 1611 | 608 | 3.32 / 379.72 | 2 | 5 |
5 | 13 | 42.96 | 25 | 15.26 | 381 | 145 | 3.47 / 379.87 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.23 | 299 | 774 | 4.24 / 380.64 | 2 | 3 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 28 | 15.20 | 480 | 204 | 0.20 / 372.42 | 2 | 2 |
2 | 7 | 2007.04 | 29 | 15.04 | 3244 | 1415 | 1.62 / 373.84 | 2 | 5 |
3 | 13 | 1607.92 | 25 | 15.01 | 2696 | 1012 | 2.63 / 374.85 | 2 | 3 |
4 | 13 | 857.76 | 25 | 15.11 | 1627 | 615 | 3.25 / 375.47 | 2 | 5 |
5 | 13 | 40.96 | 25 | 15.29 | 386 | 148 | 3.39 / 375.61 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.25 | 304 | 788 | 4.18 / 376.40 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 28 | 15.18 | 485 | 206 | 0.21 / 368.20 | 2 | 2 |
2 | 7 | 2004.60 | 29 | 15.02 | 3242 | 1412 | 1.62 / 369.61 | 2 | 4 |
3 | 13 | 1598.36 | 25 | 14.99 | 2673 | 1002 | 2.62 / 370.62 | 2 | 4 |
4 | 13 | 982.72 | 25 | 15.05 | 1808 | 680 | 3.30 / 371.30 | 2 | 3 |
5 | 13 | 37.48 | 25 | 15.27 | 376 | 144 | 3.44 / 371.44 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.24 | 301 | 780 | 4.22 / 372.22 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 28 | 15.19 | 492 | 209 | 0.21 / 364.03 | 2 | 3 |
2 | 7 | 2005.08 | 29 | 15.04 | 3244 | 1415 | 1.62 / 365.44 | 2 | 3 |
3 | 13 | 1607.72 | 25 | 14.98 | 2704 | 1013 | 2.64 / 366.45 | 2 | 3 |
4 | 13 | 850.88 | 25 | 15.09 | 1621 | 612 | 3.25 / 367.07 | 2 | 3 |
5 | 13 | 40.92 | 25 | 15.27 | 382 | 146 | 3.39 / 367.21 | 2 | 4 |
6 | 8 | 0.28 | 170 | 15.24 | 303 | 785 | 4.18 / 368.00 | 2 | 7 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 28 | 15.20 | 491 | 209 | 0.21 / 359.83 | 2 | 2 |
2 | 7 | 2009.80 | 29 | 15.03 | 3253 | 1418 | 1.63 / 361.25 | 2 | 6 |
3 | 13 | 1616.32 | 25 | 15.00 | 2705 | 1014 | 2.64 / 362.26 | 2 | 5 |
4 | 13 | 869.96 | 25 | 15.09 | 1649 | 622 | 3.26 / 362.88 | 2 | 6 |
5 | 13 | 43.68 | 25 | 15.27 | 385 | 147 | 3.41 / 363.03 | 2 | 3 |
6 | 8 | -0.20 | 170 | 15.24 | 303 | 785 | 4.20 / 363.82 | 2 | 6 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 28 | 15.20 | 477 | 203 | 0.20 / 355.54 | 2 | 2 |
2 | 7 | 2004.68 | 29 | 15.05 | 3245 | 1416 | 1.62 / 356.95 | 2 | 5 |
3 | 13 | 1738.04 | 25 | 14.98 | 2872 | 1076 | 2.69 / 358.03 | 2 | 5 |
4 | 13 | 963.92 | 25 | 15.07 | 1788 | 674 | 3.37 / 358.70 | 2 | 4 |
5 | 13 | 30.92 | 25 | 15.28 | 361 | 138 | 3.51 / 358.84 | 2 | 3 |
6 | 8 | 0.28 | 170 | 15.26 | 301 | 781 | 4.29 / 359.62 | 2 | 7 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 28 | 15.19 | 496 | 211 | 0.21 / 351.40 | 2 | 2 |
2 | 7 | 2011.12 | 29 | 15.04 | 3257 | 1421 | 1.63 / 352.82 | 2 | 7 |
3 | 13 | 1601.64 | 25 | 14.99 | 2688 | 1007 | 2.64 / 353.83 | 2 | 4 |
4 | 13 | 851.44 | 25 | 15.08 | 1620 | 611 | 3.25 / 354.44 | 2 | 5 |
5 | 8 | -0.20 | 170 | 15.26 | 301 | 781 | 4.03 / 355.22 | 2 | 3 |
6 | 14 | -0.20 | 25 | 15.23 | 301 | 115 | 4.15 / 355.33 | 3 | 8 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 28 | 15.23 | 495 | 211 | 0.21 / 347.37 | 2 | 2 |
2 | 7 | 2004.96 | 29 | 15.05 | 3245 | 1416 | 1.63 / 348.78 | 2 | 5 |
3 | 13 | 1606.96 | 25 | 14.99 | 2692 | 1009 | 2.64 / 349.79 | 2 | 4 |
4 | 13 | 850.96 | 25 | 15.09 | 1616 | 610 | 3.25 / 350.40 | 2 | 4 |
5 | 8 | 0.08 | 170 | 15.26 | 303 | 786 | 4.03 / 351.19 | 2 | 4 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 28 | 15.22 | 495 | 211 | 0.21 / 343.31 | 2 | 2 |
2 | 7 | 2006.48 | 29 | 15.07 | 3257 | 1423 | 1.63 / 344.73 | 2 | 5 |
3 | 13 | 1608.84 | 25 | 15.01 | 2700 | 1013 | 2.65 / 345.75 | 2 | 4 |
4 | 13 | 872.92 | 25 | 15.09 | 1651 | 623 | 3.27 / 346.37 | 2 | 4 |
5 | 8 | 0.28 | 170 | 15.28 | 303 | 787 | 4.06 / 347.16 | 2 | 5 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 28 | 15.24 | 495 | 211 | 0.21 / 339.02 | 2 | 2 |
2 | 7 | 2002.56 | 29 | 15.08 | 3242 | 1418 | 1.63 / 340.44 | 2 | 4 |
3 | 13 | 1717.64 | 25 | 15.01 | 2851 | 1070 | 2.70 / 341.51 | 2 | 6 |
4 | 13 | 940.36 | 25 | 15.10 | 1754 | 662 | 3.36 / 342.17 | 2 | 4 |
5 | 13 | 28.40 | 25 | 15.31 | 360 | 138 | 3.50 / 342.31 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.28 | 304 | 790 | 4.29 / 343.10 | 2 | 8 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 28 | 15.22 | 499 | 213 | 0.21 / 334.97 | 2 | 2 |
2 | 7 | 2003.52 | 29 | 15.08 | 3245 | 1419 | 1.63 / 336.38 | 2 | 3 |
3 | 13 | 1600.88 | 25 | 15.02 | 2692 | 1011 | 2.64 / 337.40 | 2 | 8 |
4 | 13 | 861.24 | 25 | 15.12 | 1637 | 619 | 3.26 / 338.01 | 2 | 3 |
5 | 8 | 0.24 | 170 | 15.28 | 307 | 797 | 4.06 / 338.81 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 28 | 15.24 | 500 | 213 | 0.21 / 330.76 | 2 | 2 |
2 | 7 | 2008.08 | 29 | 15.07 | 3263 | 1426 | 1.64 / 332.18 | 2 | 3 |
3 | 13 | 1606.76 | 25 | 15.02 | 2704 | 1015 | 2.65 / 333.20 | 2 | 4 |
4 | 13 | 858.04 | 25 | 15.12 | 1631 | 617 | 3.27 / 333.81 | 2 | 4 |
5 | 13 | 38.52 | 25 | 15.31 | 378 | 145 | 3.42 / 333.96 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.28 | 306 | 795 | 4.21 / 334.75 | 2 | 9 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 28 | 15.23 | 489 | 209 | 0.21 / 326.58 | 2 | 3 |
2 | 7 | 2005.08 | 29 | 15.07 | 3246 | 1419 | 1.63 / 328.00 | 2 | 6 |
3 | 13 | 1729.64 | 25 | 15.01 | 2864 | 1075 | 2.70 / 329.08 | 2 | 4 |
4 | 13 | 950.40 | 25 | 15.11 | 1769 | 668 | 3.37 / 329.75 | 2 | 5 |
5 | 8 | 0.24 | 170 | 15.30 | 306 | 796 | 4.17 / 330.54 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 28 | 15.23 | 479 | 204 | 0.20 / 322.41 | 2 | 2 |
2 | 7 | 2010.36 | 29 | 15.06 | 3257 | 1422 | 1.63 / 323.83 | 2 | 4 |
3 | 13 | 1604.36 | 25 | 15.02 | 2691 | 1010 | 2.64 / 324.84 | 2 | 4 |
4 | 13 | 850.64 | 25 | 15.12 | 1617 | 611 | 3.25 / 325.45 | 2 | 5 |
5 | 13 | 20.36 | 25 | 15.32 | 349 | 134 | 3.38 / 325.58 | 2 | 3 |
6 | 8 | -0.04 | 170 | 15.29 | 305 | 793 | 4.17 / 326.38 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 28 | 15.24 | 495 | 211 | 0.21 / 318.19 | 2 | 2 |
2 | 7 | 2007.72 | 29 | 15.08 | 3254 | 1423 | 1.63 / 319.62 | 2 | 6 |
3 | 13 | 1614.04 | 25 | 15.04 | 2708 | 1018 | 2.65 / 320.63 | 2 | 5 |
4 | 13 | 868.68 | 25 | 15.14 | 1646 | 623 | 3.28 / 321.26 | 2 | 7 |
5 | 13 | 41.04 | 25 | 15.33 | 384 | 147 | 3.42 / 321.41 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.30 | 306 | 796 | 4.22 / 322.20 | 2 | 3 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 28 | 15.24 | 479 | 204 | 0.20 / 314.03 | 2 | 3 |
2 | 7 | 2004.36 | 29 | 15.08 | 3247 | 1420 | 1.62 / 315.45 | 2 | 4 |
3 | 13 | 1727.12 | 25 | 15.01 | 2864 | 1075 | 2.70 / 316.53 | 2 | 5 |
4 | 13 | 939.68 | 25 | 15.12 | 1744 | 659 | 3.36 / 317.19 | 2 | 5 |
5 | 8 | 0.04 | 170 | 15.30 | 306 | 796 | 4.15 / 317.98 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 28 | 15.24 | 506 | 216 | 0.22 / 309.72 | 2 | 3 |
2 | 7 | 2012.12 | 29 | 15.07 | 3242 | 1417 | 1.63 / 311.14 | 2 | 5 |
3 | 13 | 1621.36 | 25 | 15.02 | 2710 | 1018 | 2.65 / 312.16 | 2 | 8 |
4 | 13 | 861.64 | 25 | 15.12 | 1633 | 617 | 3.27 / 312.78 | 2 | 7 |
5 | 13 | 39.08 | 25 | 15.32 | 382 | 146 | 3.41 / 312.92 | 2 | 3 |
6 | 8 | -0.12 | 170 | 15.29 | 304 | 790 | 4.20 / 313.71 | 2 | 6 |
7 | 14 | -0.12 | 25 | 15.28 | 305 | 117 | 4.32 / 313.83 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 28 | 15.25 | 496 | 212 | 0.21 / 305.55 | 2 | 2 |
2 | 7 | 2010.68 | 29 | 15.07 | 3253 | 1422 | 1.63 / 306.97 | 2 | 5 |
3 | 13 | 1610.44 | 25 | 15.03 | 2701 | 1015 | 2.65 / 307.98 | 2 | 3 |
4 | 13 | 850.24 | 25 | 15.14 | 1619 | 613 | 3.26 / 308.60 | 2 | 5 |
5 | 8 | 0.20 | 170 | 15.30 | 305 | 793 | 4.05 / 309.39 | 2 | 4 |
6 | 14 | 0.20 | 25 | 15.28 | 305 | 117 | 4.17 / 309.51 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 28 | 15.25 | 496 | 212 | 0.21 / 301.44 | 2 | 2 |
2 | 7 | 2004.40 | 29 | 15.08 | 3236 | 1415 | 1.63 / 302.85 | 2 | 4 |
3 | 13 | 1598.04 | 25 | 15.03 | 2683 | 1008 | 2.64 / 303.86 | 2 | 5 |
4 | 13 | 981.92 | 25 | 15.11 | 1806 | 682 | 3.32 / 304.55 | 2 | 5 |
5 | 8 | 0.20 | 170 | 15.31 | 304 | 791 | 4.11 / 305.34 | 2 | 4 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 28 | 15.25 | 489 | 209 | 0.21 / 297.29 | 2 | 2 |
2 | 7 | 2004.20 | 29 | 15.09 | 3230 | 1413 | 1.62 / 298.70 | 2 | 3 |
3 | 13 | 1734.00 | 25 | 15.01 | 2878 | 1080 | 2.70 / 299.78 | 2 | 9 |
4 | 13 | 941.80 | 25 | 15.12 | 1746 | 660 | 3.36 / 300.44 | 2 | 4 |
5 | 8 | 0.08 | 170 | 15.31 | 303 | 789 | 4.15 / 301.23 | 2 | 6 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 28 | 15.24 | 476 | 203 | 0.20 / 293.13 | 2 | 2 |
2 | 7 | 2006.92 | 29 | 15.08 | 3263 | 1427 | 1.63 / 294.55 | 2 | 4 |
3 | 13 | 1736.84 | 25 | 15.01 | 2878 | 1080 | 2.71 / 295.63 | 2 | 4 |
4 | 13 | 941.24 | 25 | 15.11 | 1748 | 660 | 3.37 / 296.29 | 2 | 7 |
5 | 8 | 0.16 | 170 | 15.31 | 301 | 783 | 4.15 / 297.08 | 2 | 5 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 28 | 15.26 | 475 | 203 | 0.20 / 288.86 | 2 | 3 |
2 | 3 | 1017.88 | 1 | 15.43 | 1948 | 30 | 0.23 / 288.89 | 2 | 4 |
3 | 7 | 2002.92 | 29 | 15.08 | 3232 | 1413 | 1.65 / 290.30 | 2 | 5 |
4 | 13 | 1607.96 | 25 | 15.02 | 2698 | 1013 | 2.66 / 291.31 | 2 | 6 |
5 | 13 | 984.08 | 25 | 15.10 | 1814 | 685 | 3.34 / 292.00 | 2 | 3 |
6 | 13 | 33.88 | 25 | 15.33 | 368 | 141 | 3.49 / 292.14 | 2 | 3 |
7 | 8 | -0.12 | 170 | 15.30 | 302 | 786 | 4.27 / 292.92 | 2 | 6 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 28 | 15.24 | 487 | 208 | 0.21 / 284.57 | 2 | 3 |
2 | 7 | 2008.84 | 29 | 15.09 | 3254 | 1424 | 1.63 / 285.99 | 2 | 6 |
3 | 13 | 1613.40 | 25 | 15.05 | 2704 | 1017 | 2.65 / 287.01 | 2 | 4 |
4 | 13 | 997.48 | 25 | 15.12 | 1833 | 693 | 3.34 / 287.70 | 2 | 7 |
5 | 13 | 67.76 | 25 | 15.34 | 427 | 164 | 3.51 / 287.87 | 2 | 3 |
6 | 8 | 0.28 | 170 | 15.32 | 301 | 784 | 4.29 / 288.65 | 2 | 4 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 28 | 15.27 | 480 | 205 | 0.21 / 280.33 | 2 | 3 |
2 | 7 | 2004.84 | 29 | 15.07 | 3246 | 1419 | 1.62 / 281.75 | 2 | 3 |
3 | 13 | 1585.04 | 25 | 15.04 | 2664 | 1002 | 2.63 / 282.75 | 2 | 5 |
4 | 13 | 951.56 | 25 | 15.12 | 1769 | 669 | 3.29 / 283.42 | 2 | 4 |
5 | 13 | 58.16 | 25 | 15.32 | 411 | 157 | 3.45 / 283.58 | 2 | 3 |
6 | 8 | -0.04 | 170 | 15.29 | 302 | 785 | 4.24 / 284.36 | 2 | 6 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 125.44 | 28 | 15.27 | 512 | 219 | 0.22 / 276.11 | 2 | 3 |
2 | 7 | 2008.16 | 29 | 15.09 | 3263 | 1428 | 1.65 / 277.54 | 2 | 7 |
3 | 13 | 1724.60 | 25 | 15.02 | 2861 | 1074 | 2.72 / 278.61 | 2 | 7 |
4 | 13 | 801.88 | 25 | 15.17 | 1550 | 588 | 3.31 / 279.20 | 2 | 4 |
5 | 13 | 35.64 | 25 | 15.34 | 372 | 143 | 3.45 / 279.35 | 2 | 3 |
6 | 8 | -0.04 | 170 | 15.31 | 300 | 781 | 4.23 / 280.13 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.00 | 28 | 15.25 | 504 | 215 | 0.22 / 272.13 | 2 | 2 |
2 | 7 | 1768.60 | 29 | 15.15 | 2926 | 1286 | 1.50 / 273.42 | 2 | 7 |
3 | 13 | 1515.92 | 25 | 15.09 | 2568 | 969 | 2.47 / 274.39 | 2 | 3 |
4 | 13 | 756.24 | 25 | 15.20 | 1486 | 565 | 3.03 / 274.95 | 2 | 4 |
5 | 13 | 61.48 | 25 | 15.35 | 417 | 160 | 3.19 / 275.11 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.32 | 300 | 781 | 3.98 / 275.89 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 28 | 15.27 | 480 | 205 | 0.21 / 267.85 | 2 | 2 |
2 | 3 | 1016.28 | 1 | 15.40 | 1933 | 30 | 0.23 / 267.88 | 2 | 5 |
3 | 7 | 2004.56 | 29 | 15.10 | 3254 | 1425 | 1.66 / 269.30 | 2 | 7 |
4 | 13 | 1618.48 | 25 | 15.04 | 2716 | 1021 | 2.68 / 270.32 | 2 | 4 |
5 | 13 | 878.80 | 25 | 15.15 | 1661 | 629 | 3.31 / 270.95 | 2 | 3 |
6 | 13 | 91.60 | 25 | 15.34 | 470 | 180 | 3.49 / 271.13 | 2 | 3 |
7 | 8 | -0.04 | 170 | 15.31 | 302 | 786 | 4.28 / 271.92 | 2 | 6 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 15.28 | 483 | 207 | 0.21 / 263.71 | 2 | 3 |
2 | 7 | 1895.12 | 29 | 15.11 | 3099 | 1358 | 1.56 / 265.07 | 2 | 2 |
3 | 13 | 1621.12 | 25 | 15.06 | 2718 | 1023 | 2.59 / 266.09 | 2 | 5 |
4 | 13 | 878.88 | 25 | 15.17 | 1667 | 632 | 3.22 / 266.72 | 2 | 4 |
5 | 13 | 24.60 | 25 | 15.37 | 355 | 136 | 3.36 / 266.86 | 2 | 3 |
6 | 8 | 0.16 | 170 | 15.33 | 301 | 784 | 4.14 / 267.64 | 2 | 6 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 28 | 15.29 | 492 | 211 | 0.21 / 259.50 | 2 | 3 |
2 | 7 | 2005.68 | 29 | 15.10 | 3252 | 1424 | 1.63 / 260.93 | 2 | 3 |
3 | 13 | 1611.92 | 25 | 15.04 | 2700 | 1015 | 2.65 / 261.94 | 2 | 4 |
4 | 13 | 854.80 | 25 | 15.17 | 1629 | 618 | 3.27 / 262.56 | 2 | 4 |
5 | 13 | 40.76 | 25 | 15.36 | 383 | 147 | 3.41 / 262.71 | 2 | 3 |
6 | 8 | 0.16 | 170 | 15.33 | 305 | 795 | 4.21 / 263.50 | 2 | 5 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 28 | 15.29 | 490 | 210 | 0.21 / 255.19 | 2 | 2 |
2 | 3 | 1017.24 | 1 | 15.45 | 1954 | 30 | 0.24 / 255.22 | 2 | 4 |
3 | 7 | 2003.08 | 29 | 15.10 | 3234 | 1416 | 1.66 / 256.64 | 2 | 5 |
4 | 13 | 1718.88 | 25 | 15.03 | 2839 | 1067 | 2.72 / 257.70 | 2 | 6 |
5 | 13 | 927.12 | 25 | 15.14 | 1728 | 654 | 3.38 / 258.36 | 2 | 4 |
6 | 13 | 26.76 | 25 | 15.37 | 361 | 139 | 3.52 / 258.50 | 2 | 3 |
7 | 8 | 0.00 | 170 | 15.34 | 305 | 795 | 4.31 / 259.29 | 2 | 4 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 28 | 15.30 | 483 | 207 | 0.21 / 250.96 | 2 | 2 |
2 | 7 | 2004.28 | 29 | 15.10 | 3252 | 1424 | 1.63 / 252.39 | 2 | 6 |
3 | 13 | 1720.44 | 25 | 15.04 | 2856 | 1074 | 2.70 / 253.46 | 2 | 4 |
4 | 13 | 798.32 | 25 | 15.18 | 1549 | 588 | 3.29 / 254.05 | 2 | 5 |
5 | 13 | 40.16 | 25 | 15.38 | 380 | 146 | 3.44 / 254.19 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.35 | 301 | 785 | 4.22 / 254.98 | 2 | 6 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 28 | 15.31 | 499 | 214 | 0.21 / 246.70 | 2 | 2 |
2 | 7 | 2010.28 | 29 | 15.10 | 3260 | 1428 | 1.64 / 248.12 | 2 | 5 |
3 | 13 | 1751.92 | 25 | 15.03 | 2907 | 1092 | 2.73 / 249.22 | 2 | 4 |
4 | 13 | 826.52 | 25 | 15.19 | 1587 | 603 | 3.34 / 249.82 | 2 | 4 |
5 | 13 | 38.92 | 25 | 15.38 | 378 | 145 | 3.48 / 249.97 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.35 | 303 | 791 | 4.27 / 250.76 | 2 | 5 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 28 | 15.31 | 480 | 206 | 0.21 / 242.50 | 2 | 3 |
2 | 7 | 2008.64 | 29 | 15.12 | 3264 | 1431 | 1.64 / 243.93 | 2 | 4 |
3 | 13 | 1574.24 | 25 | 15.09 | 2653 | 1001 | 2.64 / 244.93 | 2 | 3 |
4 | 13 | 839.88 | 25 | 15.21 | 1616 | 614 | 3.25 / 245.54 | 2 | 8 |
5 | 13 | 32.84 | 25 | 15.40 | 369 | 142 | 3.39 / 245.69 | 2 | 3 |
6 | 8 | 0.24 | 170 | 15.37 | 305 | 797 | 4.19 / 246.48 | 2 | 7 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 28 | 15.31 | 498 | 213 | 0.21 / 238.18 | 2 | 3 |
2 | 7 | 2011.08 | 29 | 15.12 | 3259 | 1429 | 1.64 / 239.61 | 2 | 6 |
3 | 13 | 1603.04 | 25 | 15.07 | 2697 | 1016 | 2.66 / 240.62 | 2 | 4 |
4 | 13 | 850.40 | 25 | 15.20 | 1611 | 612 | 3.27 / 241.24 | 2 | 5 |
5 | 13 | 42.84 | 25 | 15.40 | 385 | 148 | 3.42 / 241.38 | 2 | 3 |
6 | 8 | -0.08 | 170 | 15.38 | 303 | 792 | 4.21 / 242.18 | 2 | 9 |
7 | 14 | -0.08 | 25 | 15.35 | 302 | 116 | 4.33 / 242.29 | 2 | 9 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 28 | 15.32 | 486 | 208 | 0.21 / 233.97 | 2 | 3 |
2 | 7 | 2002.48 | 29 | 15.12 | 3254 | 1427 | 1.64 / 235.40 | 2 | 6 |
3 | 13 | 1592.32 | 25 | 15.08 | 2681 | 1011 | 2.65 / 236.41 | 2 | 6 |
4 | 13 | 846.16 | 25 | 15.20 | 1620 | 616 | 3.26 / 237.02 | 2 | 4 |
5 | 13 | 37.20 | 25 | 15.40 | 378 | 146 | 3.41 / 237.17 | 2 | 3 |
6 | 8 | 0.24 | 170 | 15.38 | 304 | 795 | 4.20 / 237.96 | 2 | 6 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 28 | 15.35 | 495 | 213 | 0.21 / 229.70 | 2 | 3 |
2 | 7 | 1969.20 | 29 | 15.10 | 3209 | 1405 | 1.62 / 231.11 | 2 | 5 |
3 | 13 | 1694.56 | 25 | 15.05 | 2828 | 1064 | 2.68 / 232.17 | 2 | 5 |
4 | 13 | 912.20 | 25 | 15.19 | 1710 | 649 | 3.33 / 232.82 | 2 | 4 |
5 | 13 | 46.96 | 25 | 15.40 | 393 | 151 | 3.48 / 232.97 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.37 | 303 | 792 | 4.27 / 233.76 | 2 | 6 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 28 | 15.34 | 486 | 209 | 0.21 / 225.79 | 2 | 2 |
2 | 7 | 1806.12 | 29 | 15.18 | 2988 | 1315 | 1.52 / 227.11 | 2 | 3 |
3 | 13 | 1551.64 | 25 | 15.12 | 2632 | 995 | 2.52 / 228.10 | 2 | 4 |
4 | 13 | 789.60 | 25 | 15.26 | 1538 | 587 | 3.11 / 228.69 | 2 | 5 |
5 | 8 | 0.16 | 170 | 15.41 | 305 | 799 | 3.90 / 229.49 | 2 | 5 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 28 | 15.34 | 484 | 208 | 0.21 / 221.70 | 2 | 2 |
2 | 7 | 1792.40 | 29 | 15.19 | 2970 | 1308 | 1.52 / 223.01 | 2 | 7 |
3 | 13 | 1536.28 | 25 | 15.13 | 2607 | 986 | 2.50 / 224.00 | 2 | 3 |
4 | 13 | 917.08 | 25 | 15.23 | 1724 | 656 | 3.16 / 224.65 | 2 | 5 |
5 | 13 | 24.16 | 25 | 15.44 | 354 | 137 | 3.30 / 224.79 | 2 | 3 |
6 | 8 | -0.20 | 170 | 15.41 | 303 | 794 | 4.09 / 225.58 | 2 | 6 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 28 | 15.35 | 489 | 210 | 0.21 / 217.51 | 2 | 3 |
2 | 7 | 2003.92 | 29 | 15.12 | 3248 | 1424 | 1.63 / 218.93 | 2 | 4 |
3 | 13 | 1590.44 | 25 | 15.08 | 2679 | 1010 | 2.64 / 219.94 | 2 | 3 |
4 | 13 | 848.56 | 25 | 15.22 | 1615 | 615 | 3.26 / 220.55 | 2 | 4 |
5 | 13 | 32.56 | 25 | 15.42 | 368 | 142 | 3.40 / 220.70 | 2 | 3 |
6 | 8 | 0.16 | 170 | 15.40 | 305 | 798 | 4.20 / 221.49 | 2 | 6 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 28 | 15.35 | 489 | 210 | 0.21 / 213.23 | 2 | 3 |
2 | 7 | 2008.96 | 29 | 15.13 | 3251 | 1426 | 1.64 / 214.65 | 2 | 3 |
3 | 13 | 1609.80 | 25 | 15.09 | 2700 | 1019 | 2.66 / 215.67 | 2 | 3 |
4 | 13 | 983.72 | 25 | 15.19 | 1816 | 690 | 3.34 / 216.36 | 2 | 3 |
5 | 13 | 27.60 | 25 | 15.44 | 362 | 140 | 3.48 / 216.50 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.40 | 304 | 796 | 4.28 / 217.30 | 2 | 5 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 28 | 15.36 | 500 | 215 | 0.22 / 208.99 | 2 | 2 |
2 | 7 | 2003.44 | 29 | 15.12 | 3248 | 1424 | 1.64 / 210.41 | 2 | 3 |
3 | 13 | 1722.28 | 25 | 15.06 | 2862 | 1078 | 2.72 / 211.49 | 2 | 5 |
4 | 13 | 813.40 | 25 | 15.24 | 1568 | 597 | 3.31 / 212.09 | 2 | 6 |
5 | 13 | 16.00 | 25 | 15.44 | 338 | 130 | 3.44 / 212.22 | 2 | 3 |
6 | 8 | 0.08 | 170 | 15.40 | 304 | 796 | 4.24 / 213.02 | 2 | 6 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 28 | 15.36 | 490 | 211 | 0.21 / 204.92 | 2 | 2 |
2 | 7 | 2005.04 | 29 | 15.13 | 3248 | 1425 | 1.64 / 206.34 | 2 | 4 |
3 | 13 | 1600.44 | 25 | 15.09 | 2688 | 1014 | 2.65 / 207.36 | 2 | 6 |
4 | 13 | 843.80 | 25 | 15.22 | 1614 | 614 | 3.26 / 207.97 | 2 | 4 |
5 | 8 | 0.28 | 170 | 15.42 | 307 | 805 | 4.07 / 208.77 | 2 | 5 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 28 | 15.38 | 491 | 211 | 0.21 / 200.72 | 2 | 2 |
2 | 7 | 2005.32 | 29 | 15.13 | 3263 | 1432 | 1.64 / 202.15 | 2 | 3 |
3 | 13 | 1592.40 | 25 | 15.10 | 2680 | 1012 | 2.65 / 203.16 | 2 | 4 |
4 | 13 | 836.72 | 25 | 15.24 | 1601 | 610 | 3.26 / 203.77 | 2 | 5 |
5 | 13 | 25.84 | 25 | 15.45 | 355 | 137 | 3.40 / 203.91 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.41 | 305 | 799 | 4.20 / 204.71 | 2 | 7 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 28 | 15.37 | 495 | 213 | 0.21 / 196.63 | 2 | 2 |
2 | 7 | 2005.88 | 29 | 15.15 | 3255 | 1430 | 1.64 / 198.06 | 2 | 7 |
3 | 13 | 1602.52 | 25 | 15.12 | 2696 | 1019 | 2.66 / 199.08 | 2 | 4 |
4 | 13 | 843.56 | 25 | 15.25 | 1611 | 614 | 3.28 / 199.70 | 2 | 3 |
5 | 8 | -0.16 | 170 | 15.44 | 308 | 808 | 4.08 / 200.50 | 2 | 6 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 28 | 15.38 | 501 | 216 | 0.22 / 192.56 | 2 | 3 |
2 | 7 | 2007.20 | 29 | 15.15 | 3250 | 1428 | 1.64 / 193.98 | 2 | 4 |
3 | 13 | 1597.64 | 25 | 15.11 | 2686 | 1015 | 2.66 / 195.00 | 2 | 5 |
4 | 13 | 846.96 | 25 | 15.25 | 1617 | 616 | 3.27 / 195.61 | 2 | 6 |
5 | 8 | 0.24 | 170 | 15.43 | 307 | 805 | 4.08 / 196.42 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 28 | 15.39 | 504 | 217 | 0.22 / 188.49 | 2 | 3 |
2 | 7 | 2004.32 | 29 | 15.14 | 3246 | 1425 | 1.64 / 189.92 | 2 | 5 |
3 | 13 | 1585.76 | 25 | 15.11 | 2665 | 1007 | 2.65 / 190.92 | 2 | 3 |
4 | 13 | 835.60 | 25 | 15.25 | 1599 | 610 | 3.26 / 191.53 | 2 | 4 |
5 | 8 | 0.08 | 170 | 15.44 | 308 | 808 | 4.07 / 192.34 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 27 | 15.38 | 501 | 208 | 0.21 / 184.40 | 2 | 2 |
2 | 7 | 2010.08 | 29 | 15.15 | 3254 | 1430 | 1.64 / 185.83 | 2 | 3 |
3 | 13 | 1620.12 | 25 | 15.10 | 2704 | 1021 | 2.66 / 186.85 | 2 | 5 |
4 | 13 | 846.88 | 25 | 15.25 | 1621 | 618 | 3.28 / 187.46 | 2 | 3 |
5 | 8 | 0.24 | 170 | 15.44 | 308 | 808 | 4.08 / 188.27 | 2 | 8 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 27 | 15.40 | 489 | 203 | 0.20 / 180.21 | 2 | 2 |
2 | 7 | 2003.80 | 29 | 15.14 | 3239 | 1422 | 1.63 / 181.63 | 2 | 7 |
3 | 13 | 1594.00 | 25 | 15.11 | 2672 | 1009 | 2.63 / 182.64 | 2 | 6 |
4 | 13 | 841.88 | 25 | 15.26 | 1608 | 613 | 3.25 / 183.26 | 2 | 4 |
5 | 8 | 0.08 | 170 | 15.45 | 309 | 812 | 4.06 / 184.07 | 2 | 5 |
6 | 14 | 0.08 | 25 | 15.43 | 308 | 119 | 4.18 / 184.19 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 27 | 15.39 | 502 | 209 | 0.21 / 176.20 | 2 | 2 |
2 | 7 | 1799.56 | 29 | 15.21 | 2972 | 1311 | 1.52 / 177.51 | 2 | 5 |
3 | 13 | 1543.76 | 25 | 15.15 | 2610 | 989 | 2.51 / 178.50 | 2 | 5 |
4 | 13 | 790.40 | 25 | 15.29 | 1528 | 584 | 3.09 / 179.09 | 2 | 4 |
5 | 8 | -0.16 | 170 | 15.45 | 306 | 804 | 3.90 / 179.89 | 2 | 6 |
6 | 14 | -0.16 | 25 | 15.43 | 310 | 120 | 4.02 / 180.01 | 2 | 6 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 27 | 15.42 | 503 | 209 | 0.21 / 172.13 | 2 | 2 |
2 | 7 | 2006.36 | 29 | 15.15 | 3255 | 1430 | 1.64 / 173.56 | 2 | 8 |
3 | 13 | 1598.76 | 25 | 15.11 | 2685 | 1014 | 2.65 / 174.58 | 2 | 5 |
4 | 13 | 837.52 | 25 | 15.26 | 1603 | 612 | 3.27 / 175.19 | 2 | 3 |
5 | 8 | 0.20 | 170 | 15.44 | 307 | 806 | 4.07 / 175.99 | 2 | 5 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 27 | 15.41 | 493 | 205 | 0.21 / 168.58 | 2 | 2 |
2 | 7 | 1467.04 | 29 | 15.31 | 2513 | 1116 | 1.32 / 169.70 | 2 | 3 |
3 | 13 | 1372.12 | 25 | 15.24 | 2374 | 904 | 2.23 / 170.60 | 2 | 3 |
4 | 13 | 648.08 | 25 | 15.37 | 1323 | 508 | 2.73 / 171.11 | 2 | 9 |
5 | 8 | 0.32 | 170 | 15.47 | 308 | 810 | 3.54 / 171.92 | 2 | 6 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 28 | 15.43 | 490 | 212 | 0.21 / 164.95 | 2 | 3 |
2 | 7 | 1453.64 | 29 | 15.32 | 2481 | 1102 | 1.31 / 166.05 | 2 | 3 |
3 | 13 | 1351.44 | 25 | 15.25 | 2337 | 891 | 2.20 / 166.94 | 2 | 4 |
4 | 13 | 630.96 | 25 | 15.37 | 1299 | 499 | 2.70 / 167.44 | 2 | 8 |
5 | 8 | 0.28 | 170 | 15.48 | 310 | 816 | 3.52 / 168.26 | 2 | 4 |
6 | 14 | 0.28 | 25 | 15.46 | 310 | 120 | 3.64 / 168.38 | 2 | 5 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 28 | 15.44 | 502 | 217 | 0.22 / 161.41 | 2 | 3 |
2 | 7 | 1470.96 | 29 | 15.31 | 2508 | 1114 | 1.33 / 162.52 | 2 | 4 |
3 | 13 | 1370.92 | 25 | 15.24 | 2366 | 901 | 2.23 / 163.42 | 2 | 3 |
4 | 13 | 649.00 | 25 | 15.37 | 1328 | 510 | 2.74 / 163.93 | 2 | 6 |
5 | 8 | 0.00 | 170 | 15.49 | 307 | 808 | 3.55 / 164.74 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 28 | 15.45 | 482 | 209 | 0.21 / 158.14 | 2 | 2 |
2 | 7 | 1169.56 | 29 | 15.45 | 2077 | 931 | 1.14 / 159.07 | 2 | 4 |
3 | 13 | 1126.12 | 25 | 15.37 | 2011 | 773 | 1.91 / 159.85 | 2 | 3 |
4 | 13 | 700.84 | 25 | 15.40 | 1399 | 539 | 2.45 / 160.38 | 2 | 7 |
5 | 8 | 0.20 | 170 | 15.51 | 305 | 804 | 3.25 / 161.19 | 2 | 6 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 28 | 15.43 | 500 | 216 | 0.22 / 154.86 | 2 | 2 |
2 | 7 | 1206.76 | 29 | 15.43 | 2127 | 952 | 1.17 / 155.81 | 2 | 2 |
3 | 13 | 1152.36 | 25 | 15.36 | 2046 | 786 | 1.95 / 156.59 | 2 | 4 |
4 | 13 | 716.72 | 25 | 15.40 | 1417 | 546 | 2.50 / 157.14 | 2 | 9 |
5 | 8 | -0.16 | 170 | 15.51 | 301 | 794 | 3.29 / 157.93 | 2 | 5 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 27 | 15.41 | 491 | 204 | 0.20 / 151.31 | 2 | 2 |
2 | 3 | 1017.64 | 1 | 15.50 | 1959 | 30 | 0.23 / 151.34 | 2 | 6 |
3 | 7 | 1372.72 | 30 | 15.37 | 2367 | 1091 | 1.33 / 152.43 | 2 | 3 |
4 | 13 | 1287.08 | 25 | 15.28 | 2248 | 859 | 2.18 / 153.29 | 2 | 3 |
5 | 13 | 703.32 | 25 | 15.37 | 1406 | 540 | 2.73 / 153.83 | 2 | 7 |
6 | 8 | 0.16 | 170 | 15.49 | 308 | 811 | 3.54 / 154.64 | 2 | 7 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 27 | 15.45 | 489 | 204 | 0.20 / 147.59 | 2 | 2 |
2 | 7 | 1597.28 | 29 | 15.27 | 2686 | 1189 | 1.39 / 148.78 | 2 | 3 |
3 | 13 | 1480.12 | 25 | 15.21 | 2524 | 960 | 2.35 / 149.74 | 2 | 4 |
4 | 13 | 726.12 | 25 | 15.35 | 1442 | 553 | 2.91 / 150.29 | 2 | 5 |
5 | 8 | 0.28 | 170 | 15.48 | 308 | 811 | 3.72 / 151.11 | 2 | 4 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 27 | 15.43 | 485 | 202 | 0.20 / 143.81 | 2 | 3 |
2 | 7 | 1646.24 | 29 | 15.29 | 2753 | 1221 | 1.42 / 145.03 | 2 | 8 |
3 | 13 | 1533.40 | 25 | 15.20 | 2591 | 985 | 2.41 / 146.02 | 2 | 5 |
4 | 13 | 752.80 | 25 | 15.36 | 1478 | 568 | 2.97 / 146.58 | 2 | 5 |
5 | 8 | -0.04 | 170 | 15.50 | 305 | 804 | 3.78 / 147.39 | 2 | 5 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 27 | 15.40 | 495 | 206 | 0.21 / 139.91 | 2 | 3 |
2 | 7 | 1769.72 | 29 | 15.23 | 2926 | 1292 | 1.50 / 141.20 | 2 | 3 |
3 | 13 | 1642.92 | 25 | 15.15 | 2742 | 1039 | 2.54 / 142.24 | 2 | 4 |
4 | 13 | 745.92 | 25 | 15.34 | 1471 | 564 | 3.10 / 142.80 | 2 | 5 |
5 | 8 | 0.16 | 170 | 15.48 | 306 | 805 | 3.91 / 143.61 | 2 | 4 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 27 | 15.40 | 499 | 207 | 0.21 / 135.72 | 2 | 2 |
2 | 7 | 2002.36 | 29 | 15.17 | 3255 | 1432 | 1.64 / 137.15 | 2 | 5 |
3 | 13 | 1593.16 | 25 | 15.14 | 2674 | 1012 | 2.65 / 138.17 | 2 | 4 |
4 | 13 | 829.44 | 25 | 15.29 | 1588 | 607 | 3.26 / 138.77 | 2 | 5 |
5 | 13 | 16.88 | 25 | 15.50 | 337 | 131 | 3.39 / 138.90 | 2 | 3 |
6 | 8 | 0.28 | 170 | 15.46 | 304 | 799 | 4.19 / 139.70 | 2 | 5 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 27 | 15.41 | 490 | 204 | 0.20 / 131.42 | 2 | 3 |
2 | 7 | 2002.76 | 29 | 15.17 | 3249 | 1429 | 1.63 / 132.85 | 2 | 4 |
3 | 13 | 1589.36 | 25 | 15.15 | 2669 | 1011 | 2.64 / 133.86 | 2 | 3 |
4 | 13 | 826.84 | 25 | 15.29 | 1588 | 607 | 3.25 / 134.47 | 2 | 4 |
5 | 13 | 37.00 | 25 | 15.49 | 374 | 145 | 3.40 / 134.61 | 2 | 3 |
6 | 8 | -0.28 | 170 | 15.46 | 299 | 786 | 4.18 / 135.40 | 2 | 6 |
7 | 14 | -0.28 | 25 | 15.44 | 299 | 115 | 4.30 / 135.52 | 3 | 9 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 27 | 15.41 | 485 | 202 | 0.20 / 127.22 | 2 | 2 |
2 | 7 | 2004.60 | 29 | 15.17 | 3248 | 1429 | 1.63 / 128.65 | 2 | 8 |
3 | 13 | 1595.36 | 25 | 15.14 | 2678 | 1014 | 2.64 / 129.66 | 2 | 5 |
4 | 13 | 837.04 | 25 | 15.29 | 1605 | 614 | 3.26 / 130.27 | 2 | 4 |
5 | 13 | 37.28 | 25 | 15.49 | 375 | 145 | 3.40 / 130.42 | 2 | 3 |
6 | 8 | 0.04 | 170 | 15.46 | 304 | 799 | 4.20 / 131.22 | 2 | 6 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 27 | 15.41 | 489 | 203 | 0.20 / 123.25 | 2 | 3 |
2 | 7 | 1941.96 | 29 | 15.17 | 3160 | 1390 | 1.59 / 124.64 | 2 | 3 |
3 | 13 | 1537.56 | 25 | 15.16 | 2614 | 991 | 2.58 / 125.63 | 2 | 3 |
4 | 13 | 794.28 | 25 | 15.31 | 1540 | 589 | 3.17 / 126.22 | 2 | 6 |
5 | 8 | 0.12 | 170 | 15.47 | 303 | 797 | 3.97 / 127.02 | 2 | 6 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 27 | 15.43 | 478 | 199 | 0.20 / 119.13 | 2 | 3 |
2 | 7 | 1914.00 | 29 | 15.21 | 3149 | 1389 | 1.59 / 120.52 | 2 | 5 |
3 | 13 | 1526.92 | 25 | 15.18 | 2592 | 984 | 2.57 / 121.50 | 2 | 4 |
4 | 13 | 789.68 | 25 | 15.33 | 1538 | 589 | 3.16 / 122.09 | 2 | 5 |
5 | 13 | 50.12 | 25 | 15.49 | 399 | 155 | 3.32 / 122.24 | 2 | 3 |
6 | 8 | -0.16 | 170 | 15.48 | 305 | 803 | 4.12 / 123.05 | 2 | 8 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 27 | 15.43 | 491 | 205 | 0.20 / 114.92 | 2 | 3 |
2 | 7 | 1960.44 | 29 | 15.20 | 3201 | 1411 | 1.62 / 116.33 | 2 | 5 |
3 | 13 | 1550.40 | 25 | 15.17 | 2627 | 996 | 2.61 / 117.32 | 2 | 3 |
4 | 13 | 932.72 | 25 | 15.29 | 1746 | 667 | 3.28 / 117.99 | 2 | 6 |
5 | 13 | 23.60 | 25 | 15.51 | 350 | 136 | 3.41 / 118.13 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.48 | 304 | 800 | 4.21 / 118.93 | 2 | 9 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 27 | 15.45 | 483 | 201 | 0.20 / 110.79 | 2 | 3 |
2 | 7 | 1835.28 | 29 | 15.24 | 3025 | 1337 | 1.54 / 112.13 | 2 | 3 |
3 | 13 | 1566.80 | 25 | 15.19 | 2645 | 1004 | 2.54 / 113.13 | 2 | 3 |
4 | 13 | 670.76 | 25 | 15.37 | 1362 | 523 | 3.07 / 113.66 | 2 | 6 |
5 | 13 | 25.48 | 25 | 15.52 | 351 | 136 | 3.20 / 113.79 | 2 | 3 |
6 | 8 | 0.16 | 170 | 15.49 | 304 | 801 | 4.00 / 114.59 | 2 | 9 |
7 | 14 | 0.16 | 25 | 15.47 | 304 | 118 | 4.12 / 114.71 | 2 | 6 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 27 | 15.44 | 500 | 208 | 0.21 / 106.72 | 2 | 3 |
2 | 3 | 1025.08 | 1 | 15.50 | 1940 | 30 | 0.24 / 106.75 | 2 | 5 |
3 | 3 | 969.88 | -1 | 15.81 | 3 | 0 | 0.03 / 106.75 | 2 | 5 |
4 | 7 | 1666.68 | 29 | 15.29 | 2785 | 1235 | 1.47 / 107.99 | 2 | 5 |
5 | 13 | 1539.76 | 25 | 15.22 | 2609 | 993 | 2.47 / 108.98 | 2 | 3 |
6 | 13 | 909.80 | 25 | 15.33 | 1712 | 656 | 3.12 / 109.64 | 2 | 3 |
7 | 13 | 43.28 | 25 | 15.53 | 387 | 150 | 3.27 / 109.79 | 2 | 3 |
8 | 8 | 0.20 | 170 | 15.51 | 305 | 804 | 4.08 / 110.59 | 2 | 6 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 27 | 15.45 | 486 | 203 | 0.20 / 102.50 | 2 | 2 |
2 | 7 | 1728.32 | 29 | 15.29 | 2874 | 1274 | 1.48 / 103.77 | 2 | 6 |
3 | 13 | 1482.16 | 25 | 15.24 | 2535 | 966 | 2.44 / 104.74 | 2 | 3 |
4 | 13 | 988.20 | 25 | 15.30 | 1826 | 698 | 3.14 / 105.44 | 2 | 4 |
5 | 13 | 44.88 | 25 | 15.52 | 394 | 153 | 3.29 / 105.59 | 2 | 3 |
6 | 8 | -0.08 | 170 | 15.50 | 306 | 806 | 4.10 / 106.40 | 2 | 5 |
7 | 14 | -0.08 | 25 | 15.47 | 306 | 118 | 4.22 / 106.51 | 2 | 6 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 27 | 15.44 | 488 | 203 | 0.20 / 98.36 | 2 | 3 |
2 | 7 | 1672.72 | 29 | 15.29 | 2778 | 1232 | 1.44 / 99.59 | 2 | 3 |
3 | 13 | 1546.32 | 25 | 15.22 | 2617 | 996 | 2.43 / 100.58 | 2 | 3 |
4 | 13 | 892.92 | 25 | 15.33 | 1686 | 646 | 3.08 / 101.23 | 2 | 4 |
5 | 13 | 21.56 | 25 | 15.53 | 355 | 138 | 3.21 / 101.37 | 2 | 3 |
6 | 8 | -0.04 | 170 | 15.50 | 308 | 812 | 4.03 / 102.18 | 2 | 7 |
7 | 14 | -0.04 | 25 | 15.48 | 302 | 117 | 4.14 / 102.30 | 4 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 27 | 15.46 | 475 | 198 | 0.20 / 94.29 | 2 | 3 |
2 | 7 | 1678.68 | 29 | 15.27 | 2793 | 1237 | 1.44 / 95.53 | 2 | 3 |
3 | 13 | 1550.00 | 25 | 15.21 | 2623 | 997 | 2.43 / 96.53 | 2 | 5 |
4 | 13 | 955.72 | 25 | 15.30 | 1775 | 679 | 3.11 / 97.21 | 2 | 5 |
5 | 13 | 18.16 | 25 | 15.52 | 344 | 133 | 3.24 / 97.34 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.49 | 309 | 814 | 4.06 / 98.15 | 2 | 7 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 27 | 15.47 | 510 | 213 | 0.21 / 90.34 | 2 | 3 |
2 | 7 | 1690.88 | 29 | 15.30 | 2825 | 1253 | 1.47 / 91.60 | 2 | 3 |
3 | 13 | 1565.16 | 25 | 15.22 | 2636 | 1003 | 2.47 / 92.60 | 2 | 4 |
4 | 13 | 711.08 | 25 | 15.39 | 1421 | 547 | 3.02 / 93.15 | 2 | 5 |
5 | 13 | 43.24 | 25 | 15.54 | 381 | 148 | 3.16 / 93.30 | 2 | 3 |
6 | 8 | 0.12 | 170 | 15.50 | 303 | 798 | 3.96 / 94.09 | 2 | 5 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 27 | 15.45 | 488 | 204 | 0.20 / 86.57 | 2 | 2 |
2 | 7 | 1617.36 | 29 | 15.32 | 2711 | 1204 | 1.41 / 87.78 | 2 | 3 |
3 | 13 | 1496.96 | 25 | 15.25 | 2550 | 972 | 2.38 / 88.75 | 2 | 4 |
4 | 13 | 749.28 | 25 | 15.38 | 1479 | 569 | 2.95 / 89.32 | 2 | 8 |
5 | 8 | 0.20 | 170 | 15.53 | 308 | 813 | 3.76 / 90.13 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 27 | 15.48 | 504 | 211 | 0.21 / 82.56 | 2 | 3 |
2 | 7 | 1658.68 | 29 | 15.31 | 2772 | 1231 | 1.44 / 83.79 | 2 | 3 |
3 | 13 | 1535.48 | 25 | 15.24 | 2600 | 991 | 2.43 / 84.78 | 2 | 3 |
4 | 13 | 899.20 | 25 | 15.34 | 1697 | 651 | 3.08 / 85.44 | 2 | 3 |
5 | 13 | 19.80 | 25 | 15.55 | 345 | 134 | 3.22 / 85.57 | 2 | 3 |
6 | 8 | 0.00 | 170 | 15.52 | 303 | 799 | 4.02 / 86.37 | 2 | 6 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 27 | 15.47 | 491 | 205 | 0.21 / 78.78 | 2 | 3 |
2 | 7 | 1676.92 | 29 | 15.30 | 2803 | 1244 | 1.45 / 80.02 | 2 | 5 |
3 | 13 | 1547.56 | 25 | 15.25 | 2621 | 999 | 2.45 / 81.02 | 2 | 5 |
4 | 13 | 669.40 | 25 | 15.41 | 1362 | 525 | 2.97 / 81.55 | 2 | 6 |
5 | 8 | 0.16 | 170 | 15.53 | 305 | 805 | 3.78 / 82.35 | 2 | 5 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 26 | 15.49 | 496 | 200 | 0.20 / 74.81 | 2 | 3 |
2 | 3 | 1019.92 | 1 | 15.54 | 1964 | 31 | 0.23 / 74.85 | 2 | 4 |
3 | 7 | 1826.96 | 29 | 15.27 | 3018 | 1336 | 1.57 / 76.18 | 2 | 4 |
4 | 13 | 1555.08 | 25 | 15.22 | 2629 | 1000 | 2.57 / 77.18 | 2 | 3 |
5 | 13 | 771.84 | 25 | 15.37 | 1516 | 583 | 3.15 / 77.76 | 2 | 4 |
6 | 8 | 0.16 | 170 | 15.53 | 307 | 811 | 3.96 / 78.58 | 2 | 4 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 26 | 15.48 | 493 | 198 | 0.20 / 71.02 | 2 | 2 |
2 | 7 | 1781.08 | 29 | 15.28 | 2946 | 1305 | 1.50 / 72.32 | 2 | 6 |
3 | 13 | 1517.84 | 25 | 15.24 | 2579 | 983 | 2.49 / 73.31 | 2 | 4 |
4 | 13 | 621.76 | 25 | 15.42 | 1287 | 496 | 2.98 / 73.80 | 2 | 7 |
5 | 8 | 0.20 | 170 | 15.53 | 308 | 813 | 3.80 / 74.61 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 26 | 15.49 | 489 | 197 | 0.20 / 67.16 | 2 | 2 |
2 | 7 | 1758.24 | 29 | 15.30 | 2922 | 1296 | 1.49 / 68.45 | 2 | 3 |
3 | 13 | 1506.96 | 25 | 15.26 | 2563 | 978 | 2.47 / 69.43 | 2 | 3 |
4 | 13 | 762.04 | 25 | 15.40 | 1493 | 575 | 3.05 / 70.01 | 2 | 5 |
5 | 8 | 0.08 | 170 | 15.54 | 308 | 814 | 3.86 / 70.82 | 2 | 6 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 26 | 15.50 | 506 | 204 | 0.20 / 63.22 | 2 | 2 |
2 | 7 | 1819.76 | 29 | 15.29 | 3005 | 1332 | 1.54 / 64.55 | 2 | 5 |
3 | 13 | 1556.96 | 25 | 15.24 | 2641 | 1006 | 2.54 / 65.55 | 2 | 3 |
4 | 13 | 771.20 | 25 | 15.38 | 1517 | 583 | 3.13 / 66.14 | 2 | 6 |
5 | 8 | 0.04 | 170 | 15.54 | 311 | 822 | 3.95 / 66.96 | 2 | 5 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 26 | 15.49 | 493 | 199 | 0.20 / 59.41 | 2 | 2 |
2 | 7 | 1720.08 | 29 | 15.31 | 2864 | 1272 | 1.47 / 60.68 | 2 | 3 |
3 | 13 | 1465.64 | 25 | 15.26 | 2511 | 958 | 2.43 / 61.64 | 2 | 4 |
4 | 13 | 715.76 | 25 | 15.40 | 1429 | 550 | 2.98 / 62.19 | 2 | 5 |
5 | 8 | 0.24 | 170 | 15.55 | 310 | 819 | 3.80 / 63.01 | 2 | 6 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 26 | 15.48 | 482 | 194 | 0.19 / 55.54 | 2 | 2 |
2 | 7 | 1693.40 | 29 | 15.31 | 2829 | 1256 | 1.45 / 56.80 | 2 | 4 |
3 | 13 | 1565.20 | 25 | 15.24 | 2636 | 1004 | 2.45 / 57.80 | 2 | 3 |
4 | 13 | 788.00 | 25 | 15.40 | 1539 | 593 | 3.05 / 58.40 | 2 | 7 |
5 | 8 | -0.04 | 170 | 15.55 | 309 | 817 | 3.86 / 59.21 | 2 | 6 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 26 | 15.47 | 486 | 195 | 0.20 / 51.49 | 2 | 2 |
2 | 7 | 2001.88 | 30 | 15.20 | 3245 | 1480 | 1.68 / 52.97 | 2 | 7 |
3 | 13 | 1578.08 | 25 | 15.21 | 2665 | 1013 | 2.69 / 53.98 | 2 | 3 |
4 | 13 | 780.60 | 25 | 15.37 | 1530 | 588 | 3.28 / 54.57 | 2 | 5 |
5 | 8 | 0.16 | 165 | 15.53 | 305 | 782 | 4.06 / 55.35 | 2 | 6 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 26 | 15.49 | 496 | 200 | 0.20 / 47.33 | 2 | 2 |
2 | 7 | 2001.60 | 30 | 15.23 | 3249 | 1484 | 1.68 / 48.82 | 2 | 3 |
3 | 13 | 1446.84 | 25 | 15.24 | 2488 | 948 | 2.63 / 49.76 | 2 | 4 |
4 | 13 | 827.20 | 25 | 15.36 | 1593 | 612 | 3.24 / 50.38 | 2 | 7 |
5 | 13 | 20.92 | 25 | 15.56 | 347 | 135 | 3.38 / 50.51 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.52 | 305 | 781 | 4.16 / 51.29 | 2 | 8 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 26 | 15.48 | 480 | 193 | 0.19 / 43.29 | 2 | 2 |
2 | 7 | 2004.24 | 31 | 15.25 | 3253 | 1538 | 1.73 / 44.83 | 2 | 3 |
3 | 13 | 1473.44 | 25 | 15.25 | 2516 | 959 | 2.69 / 45.79 | 2 | 5 |
4 | 13 | 731.04 | 25 | 15.40 | 1450 | 558 | 3.25 / 46.35 | 2 | 7 |
5 | 8 | 0.20 | 165 | 15.54 | 307 | 787 | 4.04 / 47.13 | 2 | 4 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 26 | 15.48 | 504 | 203 | 0.20 / 39.08 | 2 | 2 |
2 | 7 | 2003.32 | 30 | 15.19 | 3253 | 1482 | 1.69 / 40.56 | 2 | 4 |
3 | 13 | 1583.76 | 25 | 15.20 | 2664 | 1012 | 2.70 / 41.58 | 2 | 3 |
4 | 13 | 794.48 | 25 | 15.36 | 1545 | 593 | 3.29 / 42.17 | 2 | 6 |
5 | 8 | -0.16 | 165 | 15.53 | 307 | 787 | 4.08 / 42.96 | 2 | 3 |
6 | 14 | -0.16 | 30 | 15.51 | 304 | 141 | 4.22 / 43.10 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 26 | 15.48 | 505 | 203 | 0.20 / 34.95 | 2 | 3 |
2 | 7 | 2003.76 | 31 | 15.21 | 3248 | 1531 | 1.73 / 36.48 | 2 | 4 |
3 | 13 | 1575.00 | 25 | 15.21 | 2655 | 1010 | 2.74 / 37.49 | 2 | 4 |
4 | 13 | 790.20 | 25 | 15.36 | 1539 | 591 | 3.34 / 38.08 | 2 | 7 |
5 | 8 | 0.08 | 165 | 15.53 | 310 | 794 | 4.13 / 38.88 | 2 | 5 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 26 | 15.48 | 491 | 198 | 0.20 / 30.90 | 2 | 3 |
2 | 7 | 2002.12 | 38 | 15.15 | 3243 | 1867 | 2.06 / 32.77 | 2 | 4 |
3 | 13 | 1264.04 | 25 | 15.27 | 2218 | 847 | 2.91 / 33.62 | 2 | 3 |
4 | 13 | 367.24 | 25 | 15.48 | 902 | 349 | 3.26 / 33.97 | 2 | 4 |
5 | 8 | 0.20 | 165 | 15.53 | 305 | 782 | 4.04 / 34.75 | 2 | 6 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 26 | 15.49 | 482 | 194 | 0.19 / 26.72 | 2 | 2 |
2 | 3 | 1017.32 | 1 | 15.54 | 1948 | 30 | 0.22 / 26.75 | 2 | 2 |
3 | 7 | 2002.00 | 38 | 15.16 | 3244 | 1869 | 2.09 / 28.61 | 2 | 3 |
4 | 13 | 1253.92 | 25 | 15.28 | 2210 | 844 | 2.94 / 29.46 | 2 | 3 |
5 | 13 | 350.84 | 25 | 15.48 | 876 | 339 | 3.28 / 29.80 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.53 | 300 | 769 | 4.05 / 30.57 | 2 | 5 |
7 | 14 | 0.20 | 30 | 15.51 | 300 | 140 | 4.18 / 30.71 | 2 | 8 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 25 | 15.50 | 495 | 192 | 0.19 / 21.98 | 2 | 2 |
2 | 3 | 1047.64 | 1 | 15.52 | 1991 | 31 | 0.22 / 22.01 | 2 | 2 |
3 | 7 | 2001.16 | 74 | 15.05 | 3237 | 3605 | 3.83 / 25.62 | 2 | 2 |
4 | 13 | 76.04 | 18 | 15.55 | 444 | 124 | 3.95 / 25.74 | 2 | 2 |
5 | 8 | -0.04 | 165 | 15.54 | 304 | 779 | 4.73 / 26.52 | 2 | 8 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 26 | 15.49 | 486 | 196 | 0.20 / 17.18 | 2 | 2 |
2 | 3 | 962.16 | -1 | 15.82 | 2 | 0 | 0.00 / 17.18 | 2 | 2 |
3 | 7 | 2004.00 | 74 | 15.04 | 3238 | 3604 | 3.80 / 20.78 | 2 | 2 |
4 | 13 | 311.80 | 18 | 15.50 | 822 | 229 | 4.03 / 21.01 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.54 | 304 | 779 | 4.81 / 21.79 | 2 | 6 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 25 | 15.49 | 497 | 192 | 0.19 / 13.33 | 2 | 2 |
2 | 7 | 1525.32 | 74 | 15.22 | 2554 | 2877 | 3.07 / 16.21 | 2 | 2 |
3 | 8 | 0.16 | 165 | 15.55 | 301 | 772 | 3.84 / 16.98 | 2 | 3 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 24 | 15.47 | 494 | 183 | 0.18 / 9.44 | 2 | 2 |
2 | 3 | 1040.52 | 1 | 15.51 | 1990 | 31 | 0.21 / 9.47 | 2 | 2 |
3 | 7 | 1520.56 | 75 | 15.21 | 2546 | 2904 | 3.12 / 12.37 | 2 | 2 |
4 | 8 | 0.04 | 165 | 15.54 | 299 | 767 | 3.89 / 13.14 | 2 | 4 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 28 | 15.46 | 490 | 212 | 0.21 / 5.18 | 2 | 2 |
2 | 3 | 894.40 | -2 | 15.80 | 2 | 0 | 0.00 / 5.18 | 2 | 2 |
3 | 3 | 968.16 | -1 | 15.83 | 2 | 0 | 0.00 / 5.18 | 2 | 2 |
4 | 7 | 1520.80 | 74 | 15.20 | 2548 | 2866 | 3.08 / 8.05 | 2 | 2 |
5 | 13 | 46.08 | 18 | 15.56 | 382 | 107 | 3.19 / 8.15 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.53 | 297 | 761 | 3.95 / 8.91 | 2 | 5 |
7 | 14 | 0.04 | 75 | 15.50 | 294 | 342 | 4.29 / 9.26 | 3 | 8 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 24 | 15.63 | 461 | 173 | 0.17 / 2.08 | 2 | 2 |
2 | 3 | 1026.64 | 1 | 15.51 | 1946 | 30 | 0.20 / 2.11 | 2 | 2 |
3 | 7 | 996.80 | 75 | 15.34 | 1803 | 2074 | 2.28 / 4.19 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.51 | 304 | 778 | 3.06 / 4.97 | 2 | 6 |
Average= | 2.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 153.68 | 24 | 15.76 | 553 | 209 | 0.21 / 0.21 | 2 | 2 |
2 | 7 | 166.24 | 74 | 15.72 | 560 | 651 | 0.86 / 0.86 | 2 | 3 |
3 | 8 | 0.28 | 240 | 15.70 | 279 | 1051 | 1.91 / 1.91 | 2 | 13 |
Average= | 1.91 (KJ/cycle) |