SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 35 | 14.87 | 449 | 234 | 0.23 / 967.05 | 2 | 2 |
2 | 12 | 1152.64 | 3 | 14.95 | 1900 | 85 | 0.32 / 967.14 | 2 | 2 |
3 | 7 | 2010.84 | 31 | 14.50 | 2873 | 1291 | 1.61 / 968.43 | 2 | 3 |
4 | 13 | 1856.00 | 24 | 14.45 | 2685 | 931 | 2.54 / 969.36 | 2 | 3 |
5 | 13 | 944.96 | 24 | 14.61 | 1584 | 555 | 3.10 / 969.92 | 2 | 4 |
6 | 13 | 402.40 | 24 | 14.78 | 893 | 317 | 3.41 / 970.23 | 2 | 6 |
7 | 13 | 99.08 | 24 | 14.90 | 460 | 164 | 3.58 / 970.40 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.89 | 309 | 759 | 4.34 / 971.16 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 35 | 14.87 | 451 | 235 | 0.23 / 962.80 | 2 | 2 |
2 | 12 | 1138.04 | 3 | 14.95 | 1886 | 85 | 0.32 / 962.89 | 2 | 2 |
3 | 7 | 2002.84 | 31 | 14.51 | 2861 | 1287 | 1.61 / 964.17 | 2 | 3 |
4 | 13 | 1703.20 | 24 | 14.48 | 2521 | 876 | 2.48 / 965.05 | 2 | 3 |
5 | 13 | 1008.72 | 24 | 14.59 | 1673 | 586 | 3.07 / 965.64 | 2 | 4 |
6 | 13 | 317.52 | 24 | 14.81 | 776 | 276 | 3.34 / 965.91 | 2 | 4 |
7 | 13 | 83.20 | 24 | 14.90 | 430 | 154 | 3.50 / 966.07 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.90 | 307 | 755 | 4.25 / 966.82 | 2 | 5 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 35 | 14.88 | 438 | 228 | 0.23 / 958.43 | 2 | 2 |
2 | 12 | 1133.32 | 3 | 14.97 | 1865 | 84 | 0.31 / 958.52 | 2 | 2 |
3 | 7 | 2003.16 | 31 | 14.52 | 2848 | 1282 | 1.59 / 959.80 | 2 | 3 |
4 | 13 | 1700.32 | 24 | 14.48 | 2506 | 871 | 2.46 / 960.67 | 2 | 3 |
5 | 13 | 1177.80 | 24 | 14.54 | 1870 | 653 | 3.12 / 961.32 | 2 | 4 |
6 | 13 | 444.52 | 24 | 14.75 | 955 | 338 | 3.46 / 961.66 | 2 | 5 |
7 | 13 | 67.80 | 24 | 14.90 | 415 | 148 | 3.60 / 961.81 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.89 | 309 | 759 | 4.36 / 962.57 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 35 | 14.87 | 445 | 232 | 0.23 / 954.21 | 2 | 2 |
2 | 12 | 1145.84 | 3 | 14.96 | 1889 | 85 | 0.32 / 954.29 | 2 | 2 |
3 | 7 | 2009.44 | 31 | 14.51 | 2865 | 1289 | 1.61 / 955.58 | 2 | 3 |
4 | 13 | 1699.60 | 24 | 14.48 | 2503 | 870 | 2.47 / 956.45 | 2 | 3 |
5 | 13 | 1004.32 | 24 | 14.59 | 1660 | 581 | 3.06 / 957.03 | 2 | 4 |
6 | 13 | 308.76 | 24 | 14.82 | 757 | 269 | 3.33 / 957.30 | 2 | 4 |
7 | 13 | 80.92 | 24 | 14.91 | 425 | 152 | 3.48 / 957.45 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.90 | 305 | 750 | 4.23 / 958.20 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 35 | 14.88 | 446 | 232 | 0.23 / 950.00 | 2 | 2 |
2 | 12 | 1153.04 | 3 | 14.96 | 1898 | 85 | 0.32 / 950.08 | 2 | 3 |
3 | 7 | 2010.40 | 31 | 14.52 | 2864 | 1289 | 1.61 / 951.37 | 3 | 3 |
4 | 13 | 1555.84 | 24 | 14.51 | 2338 | 814 | 2.42 / 952.19 | 2 | 3 |
5 | 13 | 1046.68 | 24 | 14.58 | 1717 | 601 | 3.02 / 952.79 | 2 | 4 |
6 | 13 | 332.16 | 24 | 14.80 | 796 | 283 | 3.30 / 953.07 | 2 | 4 |
7 | 13 | 87.04 | 24 | 14.90 | 438 | 157 | 3.46 / 953.23 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.89 | 306 | 752 | 4.21 / 953.98 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 35 | 14.87 | 445 | 232 | 0.23 / 945.78 | 2 | 2 |
2 | 12 | 1164.52 | 3 | 14.96 | 1904 | 85 | 0.32 / 945.86 | 2 | 2 |
3 | 7 | 2008.64 | 31 | 14.52 | 2848 | 1282 | 1.60 / 947.15 | 2 | 3 |
4 | 13 | 1696.76 | 24 | 14.49 | 2503 | 870 | 2.47 / 948.02 | 2 | 3 |
5 | 13 | 992.72 | 24 | 14.60 | 1650 | 578 | 3.05 / 948.59 | 2 | 4 |
6 | 13 | 310.76 | 24 | 14.81 | 764 | 272 | 3.32 / 948.87 | 2 | 4 |
7 | 13 | 84.24 | 24 | 14.90 | 437 | 156 | 3.48 / 949.02 | 2 | 3 |
8 | 8 | 0.00 | 165 | 14.90 | 302 | 742 | 4.22 / 949.76 | 2 | 10 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 35 | 14.89 | 441 | 230 | 0.23 / 941.54 | 2 | 2 |
2 | 12 | 1158.24 | 3 | 14.95 | 1908 | 86 | 0.32 / 941.63 | 2 | 2 |
3 | 7 | 2005.44 | 31 | 14.50 | 2848 | 1280 | 1.60 / 942.91 | 2 | 4 |
4 | 13 | 1709.72 | 24 | 14.48 | 2521 | 876 | 2.47 / 943.78 | 2 | 3 |
5 | 13 | 994.56 | 24 | 14.59 | 1648 | 577 | 3.05 / 944.36 | 2 | 4 |
6 | 13 | 298.16 | 24 | 14.82 | 752 | 267 | 3.32 / 944.63 | 2 | 3 |
7 | 13 | 89.96 | 24 | 14.90 | 447 | 160 | 3.48 / 944.79 | 2 | 3 |
8 | 8 | 0.20 | 165 | 14.90 | 309 | 760 | 4.24 / 945.55 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 35 | 14.88 | 442 | 230 | 0.23 / 937.56 | 2 | 2 |
2 | 12 | 1143.92 | 3 | 14.97 | 1887 | 85 | 0.31 / 937.64 | 2 | 2 |
3 | 7 | 1748.28 | 31 | 14.60 | 2556 | 1157 | 1.47 / 938.80 | 2 | 3 |
4 | 13 | 1601.92 | 24 | 14.55 | 2388 | 834 | 2.31 / 939.63 | 2 | 3 |
5 | 13 | 917.28 | 24 | 14.65 | 1555 | 547 | 2.85 / 940.18 | 2 | 4 |
6 | 13 | 243.12 | 24 | 14.86 | 666 | 238 | 3.09 / 940.42 | 2 | 4 |
7 | 13 | 76.40 | 24 | 14.92 | 422 | 151 | 3.24 / 940.57 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.91 | 302 | 743 | 3.98 / 941.31 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 35 | 14.88 | 435 | 227 | 0.23 / 933.37 | 2 | 2 |
2 | 12 | 1143.92 | 3 | 14.97 | 1883 | 85 | 0.31 / 933.46 | 2 | 2 |
3 | 7 | 2003.76 | 31 | 14.52 | 2845 | 1281 | 1.59 / 934.74 | 2 | 3 |
4 | 13 | 1676.80 | 24 | 14.49 | 2477 | 861 | 2.45 / 935.60 | 2 | 3 |
5 | 13 | 972.88 | 24 | 14.61 | 1615 | 566 | 3.02 / 936.17 | 2 | 3 |
6 | 13 | 286.72 | 24 | 14.83 | 722 | 257 | 3.28 / 936.42 | 2 | 3 |
7 | 13 | 79.32 | 24 | 14.91 | 427 | 153 | 3.43 / 936.58 | 2 | 3 |
8 | 8 | 0.00 | 165 | 14.90 | 305 | 750 | 4.18 / 937.33 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 35 | 14.87 | 434 | 226 | 0.23 / 929.17 | 2 | 2 |
2 | 12 | 1153.84 | 3 | 14.96 | 1898 | 85 | 0.31 / 929.26 | 2 | 2 |
3 | 7 | 2012.96 | 31 | 14.51 | 2865 | 1289 | 1.60 / 930.55 | 2 | 3 |
4 | 13 | 1704.40 | 24 | 14.48 | 2504 | 870 | 2.47 / 931.42 | 2 | 3 |
5 | 13 | 1003.56 | 24 | 14.59 | 1653 | 579 | 3.05 / 932.00 | 2 | 5 |
6 | 13 | 297.84 | 24 | 14.82 | 744 | 265 | 3.31 / 932.26 | 2 | 3 |
7 | 13 | 73.60 | 24 | 14.91 | 413 | 148 | 3.46 / 932.41 | 2 | 3 |
8 | 8 | -0.04 | 165 | 14.90 | 301 | 740 | 4.20 / 933.15 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 35 | 14.88 | 450 | 234 | 0.23 / 924.82 | 2 | 2 |
2 | 12 | 1143.92 | 3 | 14.96 | 1905 | 85 | 0.32 / 924.90 | 2 | 3 |
3 | 7 | 2006.64 | 32 | 14.51 | 2862 | 1329 | 1.65 / 926.23 | 3 | 3 |
4 | 13 | 1686.84 | 24 | 14.49 | 2488 | 865 | 2.51 / 927.10 | 2 | 3 |
5 | 13 | 982.72 | 24 | 14.60 | 1636 | 573 | 3.09 / 927.67 | 2 | 4 |
6 | 13 | 298.60 | 24 | 14.82 | 745 | 265 | 3.35 / 927.94 | 2 | 3 |
7 | 13 | 69.76 | 24 | 14.91 | 410 | 147 | 3.50 / 928.08 | 2 | 3 |
8 | 13 | 21.12 | 24 | 14.92 | 337 | 121 | 3.62 / 928.20 | 2 | 3 |
9 | 8 | 0.16 | 165 | 14.89 | 302 | 742 | 4.36 / 928.95 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 35 | 14.87 | 446 | 232 | 0.23 / 920.58 | 2 | 2 |
2 | 12 | 1138.40 | 3 | 14.97 | 1904 | 86 | 0.32 / 920.67 | 2 | 2 |
3 | 7 | 2009.68 | 31 | 14.52 | 2855 | 1285 | 1.60 / 921.95 | 2 | 3 |
4 | 13 | 1700.96 | 24 | 14.49 | 2501 | 870 | 2.47 / 922.82 | 2 | 3 |
5 | 13 | 990.00 | 24 | 14.60 | 1647 | 577 | 3.05 / 923.40 | 2 | 3 |
6 | 13 | 314.60 | 24 | 14.81 | 772 | 274 | 3.32 / 923.67 | 2 | 3 |
7 | 13 | 73.72 | 24 | 14.91 | 425 | 152 | 3.48 / 923.83 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.90 | 309 | 760 | 4.24 / 924.58 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 35 | 14.88 | 436 | 227 | 0.23 / 916.14 | 2 | 2 |
2 | 12 | 1158.44 | 3 | 14.96 | 1898 | 85 | 0.31 / 916.23 | 2 | 2 |
3 | 7 | 2005.32 | 31 | 14.52 | 2858 | 1286 | 1.60 / 917.52 | 2 | 3 |
4 | 13 | 1851.12 | 24 | 14.46 | 2688 | 933 | 2.53 / 918.45 | 2 | 3 |
5 | 13 | 945.44 | 24 | 14.62 | 1587 | 557 | 3.09 / 919.01 | 2 | 4 |
6 | 13 | 400.56 | 24 | 14.78 | 890 | 316 | 3.40 / 919.32 | 2 | 5 |
7 | 13 | 67.04 | 24 | 14.91 | 415 | 149 | 3.55 / 919.47 | 2 | 3 |
8 | 13 | 17.28 | 24 | 14.92 | 337 | 121 | 3.67 / 919.59 | 2 | 3 |
9 | 8 | 0.12 | 165 | 14.89 | 309 | 759 | 4.43 / 920.35 | 2 | 14 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 35 | 14.89 | 438 | 228 | 0.23 / 912.00 | 2 | 2 |
2 | 12 | 1167.08 | 3 | 14.95 | 1935 | 87 | 0.32 / 912.09 | 2 | 3 |
3 | 7 | 2008.36 | 31 | 14.51 | 2868 | 1290 | 1.61 / 913.38 | 3 | 3 |
4 | 13 | 1526.12 | 24 | 14.52 | 2304 | 803 | 2.41 / 914.18 | 2 | 3 |
5 | 13 | 990.32 | 24 | 14.59 | 1655 | 580 | 2.99 / 914.76 | 2 | 4 |
6 | 13 | 280.44 | 24 | 14.83 | 719 | 256 | 3.24 / 915.02 | 2 | 4 |
7 | 13 | 67.80 | 24 | 14.90 | 412 | 147 | 3.39 / 915.16 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.89 | 307 | 754 | 4.15 / 915.92 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 35 | 14.89 | 436 | 227 | 0.23 / 907.91 | 2 | 2 |
2 | 12 | 1144.28 | 3 | 14.96 | 1883 | 85 | 0.31 / 907.99 | 2 | 3 |
3 | 7 | 2012.12 | 31 | 14.51 | 2854 | 1284 | 1.60 / 909.27 | 3 | 4 |
4 | 13 | 1561.32 | 24 | 14.51 | 2351 | 819 | 2.41 / 910.09 | 2 | 3 |
5 | 13 | 907.64 | 24 | 14.62 | 1539 | 540 | 2.95 / 910.63 | 2 | 4 |
6 | 13 | 244.40 | 24 | 14.84 | 668 | 238 | 3.19 / 910.87 | 2 | 3 |
7 | 13 | 65.32 | 24 | 14.91 | 409 | 146 | 3.34 / 911.02 | 2 | 3 |
8 | 8 | 0.00 | 165 | 14.90 | 307 | 755 | 4.09 / 911.77 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 35 | 14.88 | 439 | 229 | 0.23 / 903.68 | 2 | 2 |
2 | 12 | 1152.84 | 3 | 14.95 | 1905 | 85 | 0.31 / 903.77 | 2 | 2 |
3 | 7 | 2011.32 | 31 | 14.52 | 2858 | 1286 | 1.60 / 905.05 | 2 | 4 |
4 | 13 | 1701.28 | 24 | 14.49 | 2512 | 874 | 2.47 / 905.93 | 2 | 3 |
5 | 13 | 1016.16 | 24 | 14.59 | 1673 | 586 | 3.06 / 906.51 | 2 | 4 |
6 | 13 | 304.40 | 24 | 14.82 | 757 | 269 | 3.33 / 906.78 | 2 | 4 |
7 | 13 | 76.64 | 24 | 14.90 | 422 | 151 | 3.48 / 906.93 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.90 | 304 | 747 | 4.23 / 907.68 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 35 | 14.88 | 441 | 230 | 0.23 / 899.51 | 2 | 2 |
2 | 12 | 1161.28 | 3 | 14.97 | 1913 | 86 | 0.32 / 899.60 | 2 | 2 |
3 | 7 | 2002.92 | 31 | 14.51 | 2856 | 1285 | 1.60 / 900.88 | 2 | 3 |
4 | 13 | 1674.28 | 24 | 14.49 | 2482 | 863 | 2.46 / 901.74 | 2 | 3 |
5 | 13 | 968.24 | 24 | 14.60 | 1620 | 568 | 3.03 / 902.31 | 2 | 4 |
6 | 13 | 265.04 | 24 | 14.84 | 696 | 248 | 3.28 / 902.56 | 2 | 4 |
7 | 13 | 79.08 | 24 | 14.91 | 421 | 151 | 3.43 / 902.71 | 2 | 3 |
8 | 8 | -0.04 | 165 | 14.90 | 301 | 740 | 4.17 / 903.45 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 35 | 14.88 | 445 | 232 | 0.23 / 895.30 | 2 | 2 |
2 | 12 | 1155.76 | 3 | 14.97 | 1907 | 86 | 0.32 / 895.39 | 2 | 2 |
3 | 7 | 2009.12 | 31 | 14.51 | 2865 | 1289 | 1.61 / 896.68 | 2 | 4 |
4 | 13 | 1686.84 | 24 | 14.49 | 2493 | 867 | 2.47 / 897.54 | 2 | 3 |
5 | 13 | 983.64 | 24 | 14.60 | 1645 | 576 | 3.05 / 898.12 | 2 | 4 |
6 | 13 | 279.36 | 24 | 14.83 | 727 | 259 | 3.31 / 898.38 | 2 | 4 |
7 | 13 | 70.00 | 24 | 14.91 | 416 | 149 | 3.46 / 898.53 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.90 | 307 | 755 | 4.21 / 899.28 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 35 | 14.88 | 444 | 231 | 0.23 / 891.11 | 2 | 2 |
2 | 12 | 1156.20 | 3 | 14.96 | 1921 | 86 | 0.32 / 891.20 | 2 | 2 |
3 | 7 | 2006.04 | 31 | 14.51 | 2858 | 1286 | 1.60 / 892.48 | 2 | 3 |
4 | 13 | 1674.88 | 24 | 14.50 | 2481 | 863 | 2.47 / 893.35 | 2 | 3 |
5 | 13 | 960.20 | 24 | 14.61 | 1611 | 565 | 3.03 / 893.91 | 2 | 3 |
6 | 13 | 274.80 | 24 | 14.83 | 724 | 258 | 3.29 / 894.17 | 2 | 4 |
7 | 13 | 64.60 | 24 | 14.91 | 416 | 149 | 3.44 / 894.32 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.90 | 305 | 750 | 4.19 / 895.07 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 35 | 14.89 | 441 | 230 | 0.23 / 886.89 | 2 | 2 |
2 | 12 | 1152.96 | 3 | 14.97 | 1909 | 86 | 0.32 / 886.98 | 2 | 2 |
3 | 7 | 2010.68 | 31 | 14.52 | 2859 | 1287 | 1.60 / 888.27 | 2 | 2 |
4 | 13 | 1701.80 | 24 | 14.48 | 2502 | 869 | 2.47 / 889.14 | 2 | 4 |
5 | 13 | 994.84 | 24 | 14.60 | 1647 | 577 | 3.05 / 889.71 | 2 | 4 |
6 | 13 | 289.52 | 24 | 14.83 | 736 | 262 | 3.31 / 889.98 | 2 | 4 |
7 | 13 | 71.96 | 24 | 14.91 | 425 | 152 | 3.46 / 890.13 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.90 | 307 | 755 | 4.22 / 890.88 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 35 | 14.87 | 440 | 229 | 0.23 / 882.72 | 2 | 2 |
2 | 12 | 1157.64 | 3 | 14.96 | 1907 | 86 | 0.31 / 882.81 | 2 | 2 |
3 | 7 | 2010.52 | 31 | 14.51 | 2866 | 1289 | 1.60 / 884.10 | 2 | 3 |
4 | 13 | 1537.08 | 24 | 14.51 | 2317 | 807 | 2.41 / 884.91 | 2 | 4 |
5 | 13 | 1019.72 | 24 | 14.59 | 1683 | 589 | 3.00 / 885.49 | 2 | 4 |
6 | 13 | 300.56 | 24 | 14.82 | 756 | 269 | 3.27 / 885.76 | 2 | 3 |
7 | 13 | 69.20 | 24 | 14.91 | 415 | 149 | 3.42 / 885.91 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.90 | 306 | 752 | 4.17 / 886.66 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 35 | 14.88 | 445 | 232 | 0.23 / 878.55 | 2 | 2 |
2 | 12 | 1159.16 | 3 | 14.96 | 1916 | 86 | 0.32 / 878.63 | 2 | 2 |
3 | 7 | 1995.56 | 32 | 14.50 | 2842 | 1319 | 1.64 / 879.95 | 2 | 3 |
4 | 13 | 1531.04 | 24 | 14.51 | 2329 | 811 | 2.45 / 880.76 | 2 | 3 |
5 | 13 | 880.76 | 24 | 14.63 | 1512 | 531 | 2.98 / 881.29 | 2 | 6 |
6 | 13 | 344.12 | 24 | 14.79 | 818 | 290 | 3.27 / 881.58 | 2 | 4 |
7 | 13 | 78.12 | 24 | 14.90 | 430 | 154 | 3.42 / 881.74 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.89 | 308 | 757 | 4.18 / 882.49 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 35 | 14.87 | 440 | 229 | 0.23 / 874.36 | 2 | 2 |
2 | 12 | 1154.16 | 3 | 14.95 | 1915 | 86 | 0.31 / 874.44 | 2 | 2 |
3 | 7 | 2011.96 | 31 | 14.51 | 2874 | 1293 | 1.61 / 875.74 | 2 | 3 |
4 | 13 | 1553.24 | 24 | 14.51 | 2332 | 812 | 2.42 / 876.55 | 2 | 3 |
5 | 13 | 1031.68 | 24 | 14.59 | 1695 | 594 | 3.01 / 877.14 | 2 | 3 |
6 | 13 | 307.68 | 24 | 14.81 | 763 | 271 | 3.28 / 877.41 | 2 | 4 |
7 | 13 | 70.44 | 24 | 14.90 | 415 | 148 | 3.43 / 877.56 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.90 | 306 | 752 | 4.19 / 878.32 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 35 | 14.88 | 439 | 229 | 0.23 / 870.15 | 2 | 2 |
2 | 12 | 1163.64 | 3 | 14.97 | 1924 | 86 | 0.32 / 870.24 | 2 | 2 |
3 | 7 | 2003.28 | 31 | 14.53 | 2846 | 1282 | 1.60 / 871.52 | 2 | 3 |
4 | 13 | 1543.80 | 24 | 14.52 | 2329 | 812 | 2.41 / 872.33 | 2 | 3 |
5 | 13 | 1039.96 | 24 | 14.58 | 1717 | 601 | 3.01 / 872.94 | 2 | 3 |
6 | 13 | 329.92 | 24 | 14.80 | 796 | 283 | 3.29 / 873.22 | 2 | 4 |
7 | 13 | 72.56 | 24 | 14.90 | 421 | 151 | 3.44 / 873.37 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.89 | 310 | 762 | 4.20 / 874.13 | 2 | 10 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 35 | 14.88 | 440 | 229 | 0.23 / 865.91 | 2 | 2 |
2 | 12 | 1132.16 | 3 | 14.98 | 1872 | 84 | 0.31 / 866.00 | 2 | 2 |
3 | 7 | 2004.32 | 31 | 14.52 | 2861 | 1288 | 1.60 / 867.28 | 2 | 4 |
4 | 13 | 1702.76 | 24 | 14.49 | 2510 | 873 | 2.47 / 868.16 | 2 | 3 |
5 | 13 | 1002.76 | 24 | 14.60 | 1664 | 583 | 3.06 / 868.74 | 2 | 4 |
6 | 13 | 314.84 | 24 | 14.81 | 778 | 277 | 3.33 / 869.02 | 2 | 4 |
7 | 13 | 78.28 | 24 | 14.91 | 426 | 152 | 3.49 / 869.17 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.90 | 308 | 757 | 4.24 / 869.93 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 35 | 14.88 | 447 | 233 | 0.23 / 861.69 | 2 | 2 |
2 | 12 | 1150.88 | 3 | 14.96 | 1920 | 86 | 0.32 / 861.77 | 2 | 2 |
3 | 7 | 2005.44 | 31 | 14.51 | 2866 | 1289 | 1.61 / 863.06 | 2 | 3 |
4 | 13 | 1696.16 | 24 | 14.49 | 2502 | 870 | 2.48 / 863.93 | 2 | 3 |
5 | 13 | 999.28 | 24 | 14.60 | 1655 | 580 | 3.06 / 864.51 | 2 | 4 |
6 | 13 | 297.64 | 24 | 14.82 | 746 | 265 | 3.32 / 864.78 | 2 | 4 |
7 | 13 | 72.04 | 24 | 14.91 | 418 | 150 | 3.47 / 864.93 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.90 | 308 | 757 | 4.23 / 865.68 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 35 | 14.89 | 437 | 228 | 0.23 / 857.43 | 2 | 2 |
2 | 12 | 1309.84 | 3 | 14.91 | 2097 | 94 | 0.32 / 857.53 | 2 | 2 |
3 | 7 | 2006.00 | 31 | 14.52 | 2858 | 1286 | 1.61 / 858.81 | 2 | 3 |
4 | 13 | 1704.40 | 24 | 14.48 | 2521 | 876 | 2.48 / 859.69 | 2 | 3 |
5 | 13 | 990.44 | 24 | 14.60 | 1657 | 581 | 3.06 / 860.27 | 2 | 5 |
6 | 13 | 301.40 | 24 | 14.82 | 754 | 268 | 3.33 / 860.54 | 2 | 4 |
7 | 13 | 75.32 | 24 | 14.91 | 428 | 153 | 3.49 / 860.69 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.90 | 310 | 762 | 4.25 / 861.45 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 35 | 14.87 | 445 | 232 | 0.23 / 853.25 | 2 | 2 |
2 | 12 | 1146.72 | 3 | 14.97 | 1900 | 85 | 0.32 / 853.33 | 2 | 2 |
3 | 7 | 2004.44 | 31 | 14.51 | 2855 | 1284 | 1.60 / 854.61 | 2 | 4 |
4 | 13 | 1682.20 | 24 | 14.50 | 2487 | 865 | 2.47 / 855.48 | 2 | 3 |
5 | 13 | 966.80 | 24 | 14.61 | 1616 | 567 | 3.03 / 856.05 | 2 | 4 |
6 | 13 | 266.96 | 24 | 14.84 | 697 | 248 | 3.28 / 856.30 | 2 | 3 |
7 | 13 | 67.40 | 24 | 14.91 | 410 | 147 | 3.43 / 856.44 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.90 | 310 | 762 | 4.19 / 857.20 | 2 | 11 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 35 | 14.88 | 437 | 228 | 0.23 / 849.04 | 2 | 2 |
2 | 12 | 1135.52 | 3 | 14.97 | 1899 | 85 | 0.31 / 849.12 | 2 | 2 |
3 | 7 | 2003.32 | 31 | 14.53 | 2860 | 1288 | 1.60 / 850.41 | 2 | 3 |
4 | 13 | 1682.24 | 24 | 14.50 | 2486 | 865 | 2.47 / 851.28 | 2 | 3 |
5 | 13 | 868.24 | 24 | 14.64 | 1493 | 525 | 2.99 / 851.80 | 2 | 4 |
6 | 13 | 355.16 | 24 | 14.80 | 835 | 297 | 3.29 / 852.10 | 2 | 5 |
7 | 13 | 82.96 | 24 | 14.90 | 438 | 157 | 3.44 / 852.25 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.90 | 309 | 760 | 4.20 / 853.01 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 35 | 14.89 | 433 | 226 | 0.23 / 844.84 | 2 | 2 |
2 | 12 | 1151.48 | 3 | 14.96 | 1920 | 86 | 0.31 / 844.93 | 2 | 3 |
3 | 7 | 2005.32 | 31 | 14.51 | 2865 | 1289 | 1.60 / 846.21 | 3 | 4 |
4 | 13 | 1689.00 | 24 | 14.50 | 2498 | 869 | 2.47 / 847.08 | 2 | 3 |
5 | 13 | 975.92 | 24 | 14.61 | 1625 | 570 | 3.04 / 847.65 | 2 | 4 |
6 | 13 | 283.00 | 24 | 14.83 | 724 | 258 | 3.30 / 847.91 | 2 | 4 |
7 | 13 | 75.28 | 24 | 14.91 | 422 | 151 | 3.45 / 848.06 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.90 | 304 | 747 | 4.20 / 848.81 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 35 | 14.89 | 452 | 236 | 0.24 / 840.78 | 2 | 2 |
2 | 12 | 1158.96 | 3 | 14.97 | 1932 | 87 | 0.32 / 840.86 | 2 | 2 |
3 | 7 | 2004.44 | 31 | 14.51 | 2862 | 1287 | 1.61 / 842.15 | 2 | 3 |
4 | 13 | 1545.12 | 24 | 14.52 | 2321 | 809 | 2.42 / 842.96 | 2 | 3 |
5 | 13 | 901.28 | 24 | 14.63 | 1532 | 538 | 2.96 / 843.50 | 2 | 4 |
6 | 13 | 234.52 | 24 | 14.86 | 643 | 229 | 3.19 / 843.73 | 2 | 3 |
7 | 13 | 66.32 | 24 | 14.92 | 403 | 144 | 3.33 / 843.87 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.91 | 302 | 743 | 4.07 / 844.61 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 35 | 14.88 | 440 | 229 | 0.23 / 836.57 | 2 | 2 |
2 | 12 | 1152.32 | 3 | 14.96 | 1894 | 85 | 0.31 / 836.66 | 2 | 2 |
3 | 7 | 2002.60 | 31 | 14.52 | 2860 | 1287 | 1.60 / 837.94 | 2 | 3 |
4 | 13 | 1669.84 | 24 | 14.51 | 2472 | 861 | 2.46 / 838.81 | 2 | 3 |
5 | 13 | 962.96 | 24 | 14.62 | 1614 | 566 | 3.03 / 839.37 | 2 | 4 |
6 | 13 | 290.44 | 24 | 14.83 | 736 | 262 | 3.29 / 839.63 | 2 | 3 |
7 | 13 | 84.08 | 24 | 14.92 | 433 | 155 | 3.45 / 839.79 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.91 | 306 | 753 | 4.20 / 840.54 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 35 | 14.89 | 436 | 227 | 0.23 / 832.40 | 2 | 2 |
2 | 12 | 1152.32 | 3 | 14.97 | 1890 | 85 | 0.31 / 832.48 | 2 | 2 |
3 | 7 | 2010.96 | 31 | 14.52 | 2862 | 1288 | 1.60 / 833.77 | 2 | 3 |
4 | 13 | 1553.00 | 24 | 14.52 | 2336 | 814 | 2.41 / 834.58 | 2 | 3 |
5 | 13 | 1026.72 | 24 | 14.59 | 1690 | 592 | 3.01 / 835.17 | 2 | 3 |
6 | 13 | 301.52 | 24 | 14.82 | 749 | 266 | 3.27 / 835.44 | 2 | 4 |
7 | 13 | 77.68 | 24 | 14.91 | 424 | 152 | 3.42 / 835.59 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.90 | 305 | 750 | 4.17 / 836.34 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 35 | 14.89 | 439 | 229 | 0.23 / 828.18 | 2 | 2 |
2 | 12 | 1156.20 | 3 | 14.96 | 1910 | 86 | 0.31 / 828.27 | 2 | 3 |
3 | 7 | 2003.80 | 31 | 14.54 | 2866 | 1292 | 1.61 / 829.56 | 3 | 3 |
4 | 13 | 1690.68 | 24 | 14.50 | 2500 | 870 | 2.48 / 830.43 | 2 | 3 |
5 | 13 | 991.44 | 24 | 14.61 | 1653 | 580 | 3.06 / 831.01 | 2 | 4 |
6 | 13 | 305.88 | 24 | 14.83 | 757 | 269 | 3.33 / 831.28 | 2 | 4 |
7 | 13 | 80.44 | 24 | 14.92 | 423 | 151 | 3.48 / 831.43 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.91 | 300 | 738 | 4.21 / 832.17 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 35 | 14.89 | 438 | 228 | 0.23 / 823.91 | 2 | 2 |
2 | 12 | 1149.12 | 3 | 14.96 | 1913 | 86 | 0.31 / 824.00 | 2 | 2 |
3 | 7 | 2012.20 | 31 | 14.51 | 2878 | 1295 | 1.61 / 825.29 | 2 | 3 |
4 | 13 | 1856.60 | 24 | 14.46 | 2682 | 931 | 2.54 / 826.22 | 2 | 3 |
5 | 13 | 977.20 | 24 | 14.61 | 1630 | 572 | 3.11 / 826.80 | 2 | 4 |
6 | 13 | 292.96 | 24 | 14.83 | 737 | 262 | 3.37 / 827.06 | 2 | 4 |
7 | 13 | 77.76 | 24 | 14.92 | 421 | 151 | 3.52 / 827.21 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.91 | 303 | 745 | 4.27 / 827.95 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 35 | 14.90 | 436 | 227 | 0.23 / 819.65 | 2 | 2 |
2 | 12 | 1164.80 | 3 | 14.97 | 1911 | 86 | 0.31 / 819.74 | 2 | 2 |
3 | 7 | 2009.20 | 32 | 14.52 | 2865 | 1331 | 1.64 / 821.07 | 2 | 4 |
4 | 13 | 1707.24 | 24 | 14.49 | 2522 | 877 | 2.52 / 821.95 | 2 | 3 |
5 | 13 | 984.24 | 24 | 14.61 | 1642 | 576 | 3.10 / 822.52 | 2 | 3 |
6 | 13 | 281.20 | 24 | 14.83 | 719 | 256 | 3.35 / 822.78 | 2 | 3 |
7 | 13 | 77.88 | 24 | 14.91 | 426 | 152 | 3.51 / 822.93 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.91 | 306 | 753 | 4.26 / 823.68 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 35 | 14.89 | 435 | 227 | 0.23 / 815.55 | 2 | 2 |
2 | 12 | 1165.68 | 3 | 14.96 | 1936 | 87 | 0.31 / 815.63 | 2 | 2 |
3 | 7 | 2011.00 | 32 | 14.52 | 2869 | 1333 | 1.65 / 816.97 | 2 | 3 |
4 | 13 | 1547.84 | 24 | 14.52 | 2325 | 810 | 2.46 / 817.78 | 2 | 3 |
5 | 13 | 891.44 | 24 | 14.63 | 1530 | 537 | 2.99 / 818.31 | 2 | 4 |
6 | 13 | 241.40 | 24 | 14.86 | 659 | 235 | 3.23 / 818.55 | 2 | 3 |
7 | 13 | 69.56 | 24 | 14.92 | 401 | 144 | 3.37 / 818.69 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.92 | 298 | 734 | 4.11 / 819.43 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 35 | 14.91 | 432 | 225 | 0.23 / 811.32 | 2 | 2 |
2 | 12 | 1146.24 | 3 | 14.97 | 1899 | 85 | 0.31 / 811.41 | 2 | 2 |
3 | 7 | 2013.16 | 31 | 14.52 | 2866 | 1290 | 1.60 / 812.70 | 2 | 3 |
4 | 13 | 1705.48 | 24 | 14.50 | 2515 | 875 | 2.48 / 813.57 | 2 | 3 |
5 | 13 | 992.76 | 24 | 14.61 | 1653 | 580 | 3.06 / 814.15 | 2 | 4 |
6 | 13 | 302.20 | 24 | 14.83 | 750 | 267 | 3.32 / 814.42 | 2 | 4 |
7 | 13 | 76.88 | 24 | 14.92 | 425 | 152 | 3.47 / 814.57 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.91 | 304 | 748 | 4.22 / 815.32 | 2 | 10 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 35 | 14.88 | 444 | 231 | 0.23 / 807.04 | 2 | 2 |
2 | 12 | 1160.16 | 3 | 14.97 | 1938 | 87 | 0.32 / 807.12 | 2 | 2 |
3 | 7 | 2013.96 | 32 | 14.52 | 2860 | 1329 | 1.65 / 808.45 | 2 | 3 |
4 | 13 | 1861.48 | 24 | 14.46 | 2695 | 935 | 2.58 / 809.39 | 2 | 3 |
5 | 13 | 957.60 | 24 | 14.63 | 1611 | 566 | 3.15 / 809.95 | 2 | 4 |
6 | 13 | 281.24 | 24 | 14.85 | 717 | 256 | 3.40 / 810.21 | 2 | 3 |
7 | 13 | 83.08 | 24 | 14.92 | 424 | 152 | 3.56 / 810.36 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.92 | 299 | 736 | 4.29 / 811.10 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 35 | 14.89 | 445 | 232 | 0.23 / 802.73 | 2 | 2 |
2 | 12 | 1160.04 | 3 | 14.98 | 1906 | 86 | 0.32 / 802.82 | 2 | 2 |
3 | 7 | 2006.80 | 31 | 14.53 | 2870 | 1293 | 1.61 / 804.11 | 2 | 3 |
4 | 13 | 1686.36 | 24 | 14.51 | 2489 | 867 | 2.48 / 804.98 | 2 | 3 |
5 | 13 | 981.60 | 24 | 14.61 | 1635 | 573 | 3.05 / 805.55 | 2 | 4 |
6 | 13 | 423.24 | 24 | 14.77 | 921 | 326 | 3.38 / 805.88 | 2 | 7 |
7 | 13 | 110.08 | 24 | 14.90 | 472 | 169 | 3.55 / 806.05 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.90 | 308 | 757 | 4.30 / 806.81 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 35 | 14.90 | 442 | 231 | 0.23 / 798.56 | 2 | 2 |
2 | 12 | 1136.28 | 3 | 14.98 | 1881 | 85 | 0.32 / 798.64 | 2 | 2 |
3 | 7 | 2002.80 | 31 | 14.52 | 2855 | 1285 | 1.60 / 799.93 | 2 | 3 |
4 | 13 | 1681.08 | 24 | 14.50 | 2478 | 862 | 2.46 / 800.79 | 2 | 3 |
5 | 13 | 967.64 | 24 | 14.62 | 1617 | 567 | 3.03 / 801.36 | 2 | 4 |
6 | 13 | 275.88 | 24 | 14.85 | 707 | 252 | 3.28 / 801.61 | 2 | 3 |
7 | 13 | 80.32 | 24 | 14.92 | 420 | 150 | 3.43 / 801.76 | 2 | 3 |
8 | 8 | -0.04 | 165 | 14.91 | 302 | 743 | 4.18 / 802.50 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 35 | 14.90 | 434 | 226 | 0.23 / 794.35 | 2 | 2 |
2 | 12 | 1144.24 | 3 | 14.97 | 1885 | 85 | 0.31 / 794.43 | 2 | 2 |
3 | 7 | 2003.76 | 31 | 14.52 | 2854 | 1285 | 1.60 / 795.72 | 2 | 3 |
4 | 13 | 1670.60 | 24 | 14.51 | 2481 | 864 | 2.46 / 796.58 | 2 | 5 |
5 | 13 | 990.96 | 24 | 14.61 | 1654 | 580 | 3.04 / 797.16 | 2 | 3 |
6 | 13 | 292.76 | 24 | 14.84 | 735 | 262 | 3.30 / 797.42 | 2 | 3 |
7 | 13 | 88.52 | 24 | 14.92 | 435 | 156 | 3.46 / 797.58 | 2 | 3 |
8 | 8 | 0.24 | 165 | 14.91 | 304 | 748 | 4.20 / 798.33 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 35 | 14.89 | 442 | 230 | 0.23 / 790.01 | 2 | 2 |
2 | 12 | 1296.48 | 3 | 14.92 | 2118 | 95 | 0.33 / 790.11 | 2 | 2 |
3 | 7 | 2008.32 | 31 | 14.53 | 2873 | 1294 | 1.62 / 791.40 | 2 | 4 |
4 | 13 | 1685.28 | 24 | 14.51 | 2497 | 870 | 2.49 / 792.27 | 2 | 3 |
5 | 13 | 990.68 | 24 | 14.62 | 1639 | 575 | 3.06 / 792.85 | 2 | 3 |
6 | 13 | 299.12 | 24 | 14.84 | 743 | 265 | 3.33 / 793.11 | 2 | 4 |
7 | 13 | 82.56 | 24 | 14.92 | 427 | 153 | 3.48 / 793.27 | 2 | 3 |
8 | 8 | 0.00 | 165 | 14.91 | 303 | 745 | 4.23 / 794.01 | 2 | 13 |
9 | 14 | 0.00 | 25 | 14.89 | 301 | 112 | 4.34 / 794.12 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 35 | 14.90 | 455 | 237 | 0.24 / 785.78 | 2 | 2 |
2 | 12 | 1312.36 | 3 | 14.92 | 2097 | 94 | 0.33 / 785.88 | 2 | 2 |
3 | 7 | 2003.52 | 31 | 14.52 | 2859 | 1287 | 1.62 / 787.16 | 2 | 3 |
4 | 13 | 1691.52 | 24 | 14.50 | 2506 | 872 | 2.49 / 788.04 | 2 | 3 |
5 | 13 | 989.12 | 24 | 14.61 | 1648 | 578 | 3.07 / 788.61 | 2 | 3 |
6 | 13 | 296.60 | 24 | 14.84 | 746 | 266 | 3.33 / 788.88 | 2 | 3 |
7 | 13 | 86.76 | 24 | 14.92 | 435 | 156 | 3.49 / 789.04 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.91 | 304 | 748 | 4.24 / 789.78 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 35 | 14.89 | 450 | 235 | 0.23 / 781.66 | 2 | 2 |
2 | 12 | 1140.76 | 3 | 14.98 | 1883 | 85 | 0.32 / 781.75 | 2 | 2 |
3 | 7 | 2010.28 | 31 | 14.54 | 2854 | 1286 | 1.61 / 783.04 | 2 | 4 |
4 | 13 | 1567.04 | 24 | 14.52 | 2361 | 823 | 2.43 / 783.86 | 2 | 3 |
5 | 13 | 929.60 | 24 | 14.63 | 1574 | 553 | 2.98 / 784.41 | 2 | 3 |
6 | 13 | 259.60 | 24 | 14.86 | 689 | 246 | 3.23 / 784.66 | 2 | 3 |
7 | 13 | 82.44 | 24 | 14.92 | 422 | 151 | 3.38 / 784.81 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.92 | 300 | 739 | 4.12 / 785.55 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 35 | 14.91 | 434 | 226 | 0.23 / 777.43 | 2 | 2 |
2 | 12 | 1137.84 | 3 | 14.97 | 1888 | 85 | 0.31 / 777.52 | 2 | 2 |
3 | 7 | 2008.88 | 31 | 14.54 | 2861 | 1290 | 1.60 / 778.81 | 2 | 4 |
4 | 13 | 1692.48 | 24 | 14.51 | 2496 | 869 | 2.47 / 779.68 | 2 | 3 |
5 | 13 | 992.12 | 24 | 14.62 | 1643 | 576 | 3.05 / 780.25 | 2 | 4 |
6 | 13 | 308.20 | 24 | 14.84 | 759 | 270 | 3.32 / 780.53 | 2 | 4 |
7 | 13 | 86.20 | 24 | 14.92 | 432 | 155 | 3.47 / 780.68 | 2 | 3 |
8 | 8 | 0.00 | 165 | 14.91 | 305 | 750 | 4.22 / 781.43 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 35 | 14.89 | 446 | 232 | 0.23 / 773.21 | 2 | 2 |
2 | 12 | 1156.92 | 3 | 14.98 | 1901 | 85 | 0.32 / 773.30 | 2 | 2 |
3 | 7 | 2011.56 | 31 | 14.54 | 2857 | 1288 | 1.61 / 774.58 | 2 | 3 |
4 | 13 | 1710.16 | 24 | 14.50 | 2522 | 878 | 2.48 / 775.46 | 2 | 3 |
5 | 13 | 968.76 | 24 | 14.63 | 1623 | 570 | 3.05 / 776.03 | 2 | 3 |
6 | 13 | 288.64 | 24 | 14.85 | 737 | 263 | 3.32 / 776.29 | 2 | 3 |
7 | 13 | 84.44 | 24 | 14.93 | 434 | 156 | 3.47 / 776.45 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.92 | 308 | 758 | 4.23 / 777.21 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 35 | 14.90 | 438 | 228 | 0.23 / 769.01 | 2 | 2 |
2 | 12 | 1145.68 | 3 | 14.98 | 1895 | 85 | 0.31 / 769.09 | 2 | 2 |
3 | 7 | 2001.88 | 31 | 14.53 | 2846 | 1282 | 1.60 / 770.37 | 2 | 3 |
4 | 13 | 1540.48 | 24 | 14.53 | 2327 | 811 | 2.41 / 771.18 | 2 | 3 |
5 | 13 | 1029.36 | 24 | 14.60 | 1697 | 595 | 3.00 / 771.78 | 2 | 4 |
6 | 13 | 321.56 | 24 | 14.83 | 785 | 279 | 3.28 / 772.06 | 2 | 4 |
7 | 13 | 81.88 | 24 | 14.92 | 433 | 155 | 3.44 / 772.21 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.91 | 311 | 765 | 4.20 / 772.98 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 35 | 14.88 | 443 | 231 | 0.23 / 764.79 | 2 | 2 |
2 | 12 | 1155.08 | 3 | 14.97 | 1915 | 86 | 0.32 / 764.87 | 2 | 2 |
3 | 7 | 2005.96 | 31 | 14.54 | 2864 | 1291 | 1.61 / 766.16 | 2 | 4 |
4 | 13 | 1689.48 | 24 | 14.51 | 2490 | 867 | 2.47 / 767.03 | 2 | 3 |
5 | 13 | 981.76 | 24 | 14.63 | 1635 | 574 | 3.05 / 767.61 | 2 | 3 |
6 | 13 | 305.24 | 24 | 14.84 | 759 | 270 | 3.32 / 767.88 | 2 | 4 |
7 | 13 | 85.36 | 24 | 14.93 | 433 | 155 | 3.47 / 768.03 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.92 | 303 | 746 | 4.22 / 768.78 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 35 | 14.90 | 442 | 231 | 0.23 / 760.43 | 2 | 2 |
2 | 12 | 1148.28 | 3 | 14.98 | 1912 | 86 | 0.32 / 760.52 | 2 | 2 |
3 | 7 | 2007.20 | 32 | 14.53 | 2868 | 1334 | 1.65 / 761.85 | 2 | 3 |
4 | 13 | 1562.12 | 24 | 14.53 | 2348 | 819 | 2.47 / 762.67 | 2 | 5 |
5 | 13 | 1019.84 | 24 | 14.61 | 1689 | 592 | 3.06 / 763.27 | 2 | 4 |
6 | 13 | 311.12 | 24 | 14.83 | 765 | 272 | 3.33 / 763.54 | 2 | 4 |
7 | 13 | 81.64 | 24 | 14.92 | 426 | 153 | 3.49 / 763.69 | 2 | 3 |
8 | 13 | 21.56 | 24 | 14.94 | 339 | 122 | 3.61 / 763.81 | 2 | 3 |
9 | 8 | -0.08 | 165 | 14.91 | 303 | 745 | 4.35 / 764.56 | 2 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 35 | 14.89 | 437 | 228 | 0.23 / 756.10 | 2 | 2 |
2 | 12 | 1142.08 | 3 | 14.99 | 1899 | 85 | 0.31 / 756.19 | 2 | 2 |
3 | 7 | 2008.08 | 31 | 14.54 | 2865 | 1291 | 1.60 / 757.48 | 2 | 3 |
4 | 13 | 1701.56 | 24 | 14.51 | 2505 | 872 | 2.48 / 758.35 | 2 | 3 |
5 | 13 | 979.84 | 24 | 14.63 | 1635 | 574 | 3.05 / 758.92 | 2 | 4 |
6 | 13 | 294.04 | 24 | 14.85 | 745 | 266 | 3.32 / 759.19 | 2 | 3 |
7 | 13 | 81.80 | 24 | 14.93 | 425 | 152 | 3.47 / 759.34 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.92 | 305 | 751 | 4.22 / 760.09 | 2 | 7 |
9 | 14 | 0.04 | 25 | 14.90 | 303 | 113 | 4.33 / 760.20 | 2 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 35 | 14.90 | 447 | 233 | 0.23 / 751.77 | 2 | 2 |
2 | 12 | 1147.36 | 3 | 14.99 | 1894 | 85 | 0.32 / 751.86 | 2 | 2 |
3 | 7 | 2004.00 | 32 | 14.54 | 2852 | 1327 | 1.65 / 753.19 | 2 | 3 |
4 | 13 | 1534.88 | 24 | 14.54 | 2319 | 809 | 2.45 / 754.00 | 2 | 3 |
5 | 13 | 1021.68 | 24 | 14.61 | 1680 | 589 | 3.04 / 754.59 | 2 | 3 |
6 | 13 | 298.84 | 24 | 14.84 | 744 | 265 | 3.31 / 754.85 | 2 | 3 |
7 | 13 | 73.04 | 24 | 14.93 | 415 | 149 | 3.46 / 755.00 | 2 | 3 |
8 | 13 | 16.28 | 24 | 14.94 | 335 | 120 | 3.58 / 755.12 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.91 | 306 | 753 | 4.33 / 755.87 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 35 | 14.90 | 444 | 232 | 0.23 / 747.56 | 2 | 2 |
2 | 12 | 1149.60 | 3 | 14.97 | 1912 | 86 | 0.32 / 747.65 | 2 | 2 |
3 | 7 | 2010.76 | 31 | 14.52 | 2878 | 1295 | 1.61 / 748.95 | 2 | 4 |
4 | 13 | 1691.32 | 24 | 14.51 | 2495 | 869 | 2.48 / 749.81 | 2 | 3 |
5 | 13 | 996.80 | 24 | 14.62 | 1648 | 578 | 3.06 / 750.39 | 2 | 3 |
6 | 13 | 285.80 | 24 | 14.85 | 721 | 257 | 3.32 / 750.65 | 2 | 4 |
7 | 13 | 87.36 | 24 | 14.93 | 429 | 154 | 3.47 / 750.80 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.92 | 300 | 739 | 4.21 / 751.54 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 35 | 14.89 | 441 | 230 | 0.23 / 743.23 | 2 | 2 |
2 | 12 | 1149.08 | 3 | 14.98 | 1891 | 85 | 0.31 / 743.31 | 2 | 2 |
3 | 7 | 2004.16 | 31 | 14.54 | 2866 | 1292 | 1.61 / 744.60 | 2 | 4 |
4 | 13 | 1688.36 | 24 | 14.52 | 2496 | 870 | 2.48 / 745.47 | 2 | 3 |
5 | 13 | 979.64 | 24 | 14.63 | 1637 | 575 | 3.05 / 746.05 | 2 | 4 |
6 | 13 | 298.64 | 24 | 14.85 | 747 | 266 | 3.32 / 746.31 | 2 | 4 |
7 | 13 | 93.20 | 24 | 14.93 | 439 | 157 | 3.47 / 746.47 | 2 | 3 |
8 | 13 | 27.08 | 24 | 14.95 | 343 | 123 | 3.60 / 746.59 | 2 | 3 |
9 | 8 | 0.16 | 165 | 14.92 | 300 | 739 | 4.34 / 747.33 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 35 | 14.89 | 444 | 231 | 0.23 / 738.88 | 2 | 2 |
2 | 12 | 1156.76 | 3 | 14.98 | 1907 | 86 | 0.32 / 738.97 | 2 | 2 |
3 | 7 | 2009.52 | 31 | 14.53 | 2871 | 1293 | 1.61 / 740.26 | 2 | 4 |
4 | 13 | 1689.00 | 24 | 14.51 | 2494 | 869 | 2.48 / 741.13 | 2 | 3 |
5 | 13 | 997.16 | 24 | 14.62 | 1662 | 583 | 3.06 / 741.71 | 2 | 3 |
6 | 13 | 302.16 | 24 | 14.84 | 754 | 269 | 3.33 / 741.98 | 2 | 3 |
7 | 13 | 80.16 | 24 | 14.93 | 426 | 153 | 3.48 / 742.13 | 2 | 3 |
8 | 13 | 19.68 | 24 | 14.95 | 334 | 120 | 3.60 / 742.25 | 2 | 3 |
9 | 8 | 0.08 | 165 | 14.91 | 302 | 743 | 4.35 / 743.00 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 35 | 14.91 | 446 | 233 | 0.23 / 734.34 | 2 | 2 |
2 | 12 | 1297.24 | 3 | 14.94 | 2083 | 93 | 0.33 / 734.43 | 2 | 2 |
3 | 7 | 2004.32 | 31 | 14.55 | 2863 | 1291 | 1.62 / 735.72 | 2 | 3 |
4 | 13 | 1849.28 | 24 | 14.48 | 2691 | 935 | 2.55 / 736.66 | 2 | 4 |
5 | 13 | 1132.88 | 24 | 14.58 | 1829 | 640 | 3.19 / 737.30 | 2 | 4 |
6 | 13 | 400.72 | 24 | 14.80 | 886 | 315 | 3.51 / 737.61 | 2 | 4 |
7 | 13 | 110.28 | 24 | 14.91 | 472 | 169 | 3.68 / 737.78 | 2 | 3 |
8 | 13 | 28.24 | 24 | 14.94 | 349 | 125 | 3.80 / 737.90 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.91 | 303 | 745 | 4.55 / 738.65 | 2 | 10 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 35 | 14.90 | 437 | 228 | 0.23 / 730.13 | 2 | 2 |
2 | 12 | 1142.44 | 3 | 14.98 | 1909 | 86 | 0.31 / 730.21 | 2 | 2 |
3 | 7 | 2008.92 | 31 | 14.54 | 2877 | 1297 | 1.61 / 731.51 | 2 | 4 |
4 | 13 | 1552.40 | 24 | 14.54 | 2339 | 816 | 2.43 / 732.33 | 2 | 3 |
5 | 13 | 1026.08 | 24 | 14.61 | 1704 | 597 | 3.02 / 732.92 | 2 | 4 |
6 | 13 | 328.00 | 24 | 14.83 | 788 | 280 | 3.30 / 733.20 | 2 | 4 |
7 | 13 | 92.04 | 24 | 14.92 | 444 | 159 | 3.46 / 733.36 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.93 | 301 | 741 | 4.21 / 734.10 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 35 | 14.90 | 446 | 233 | 0.23 / 725.75 | 2 | 2 |
2 | 12 | 1151.60 | 3 | 14.97 | 1908 | 86 | 0.32 / 725.84 | 2 | 2 |
3 | 7 | 2005.68 | 31 | 14.55 | 2859 | 1290 | 1.61 / 727.13 | 2 | 3 |
4 | 13 | 1853.40 | 24 | 14.49 | 2687 | 934 | 2.54 / 728.06 | 2 | 3 |
5 | 13 | 954.80 | 24 | 14.64 | 1596 | 561 | 3.10 / 728.62 | 2 | 4 |
6 | 13 | 288.24 | 24 | 14.85 | 733 | 261 | 3.36 / 728.88 | 2 | 4 |
7 | 13 | 81.44 | 24 | 14.93 | 427 | 153 | 3.52 / 729.04 | 2 | 3 |
8 | 13 | 19.80 | 24 | 14.95 | 336 | 121 | 3.64 / 729.16 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.92 | 301 | 741 | 4.38 / 729.90 | 2 | 9 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 35 | 14.90 | 451 | 235 | 0.24 / 721.38 | 2 | 2 |
2 | 12 | 1297.40 | 3 | 14.94 | 2099 | 94 | 0.33 / 721.48 | 2 | 2 |
3 | 7 | 2006.88 | 31 | 14.55 | 2858 | 1289 | 1.62 / 722.77 | 2 | 3 |
4 | 13 | 1696.68 | 24 | 14.51 | 2508 | 873 | 2.49 / 723.64 | 2 | 3 |
5 | 13 | 1005.24 | 24 | 14.62 | 1669 | 586 | 3.08 / 724.23 | 2 | 5 |
6 | 13 | 320.88 | 24 | 14.84 | 771 | 275 | 3.35 / 724.50 | 2 | 4 |
7 | 13 | 88.12 | 24 | 14.93 | 433 | 155 | 3.51 / 724.66 | 2 | 3 |
8 | 13 | 23.48 | 24 | 14.95 | 340 | 122 | 3.63 / 724.78 | 2 | 3 |
9 | 8 | 0.08 | 165 | 14.92 | 301 | 741 | 4.37 / 725.52 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 35 | 14.91 | 437 | 228 | 0.23 / 716.93 | 2 | 2 |
2 | 12 | 1145.52 | 3 | 15.00 | 1879 | 85 | 0.31 / 717.01 | 2 | 2 |
3 | 7 | 2004.68 | 31 | 14.55 | 2857 | 1289 | 1.60 / 718.30 | 2 | 3 |
4 | 13 | 1666.40 | 24 | 14.52 | 2468 | 860 | 2.46 / 719.16 | 2 | 3 |
5 | 13 | 1126.52 | 24 | 14.59 | 1817 | 636 | 3.10 / 719.80 | 2 | 3 |
6 | 13 | 383.96 | 24 | 14.80 | 875 | 311 | 3.41 / 720.11 | 2 | 4 |
7 | 13 | 106.72 | 24 | 14.92 | 466 | 167 | 3.58 / 720.27 | 2 | 3 |
8 | 13 | 31.52 | 24 | 14.94 | 359 | 129 | 3.70 / 720.40 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.91 | 304 | 748 | 4.45 / 721.15 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 35 | 14.91 | 442 | 231 | 0.23 / 712.61 | 2 | 2 |
2 | 12 | 1145.88 | 3 | 14.98 | 1891 | 85 | 0.32 / 712.70 | 2 | 2 |
3 | 7 | 2007.36 | 31 | 14.55 | 2860 | 1290 | 1.61 / 713.99 | 2 | 3 |
4 | 13 | 1678.84 | 24 | 14.52 | 2482 | 865 | 2.47 / 714.85 | 2 | 3 |
5 | 13 | 970.60 | 24 | 14.64 | 1625 | 571 | 3.04 / 715.42 | 2 | 3 |
6 | 13 | 292.08 | 24 | 14.86 | 736 | 262 | 3.30 / 715.68 | 2 | 4 |
7 | 13 | 87.40 | 24 | 14.94 | 430 | 154 | 3.46 / 715.84 | 2 | 3 |
8 | 13 | 23.32 | 24 | 14.95 | 341 | 122 | 3.58 / 715.96 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.93 | 299 | 737 | 4.32 / 716.70 | 2 | 9 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 35 | 14.90 | 447 | 233 | 0.23 / 708.42 | 2 | 2 |
2 | 12 | 1139.04 | 3 | 14.99 | 1897 | 85 | 0.32 / 708.50 | 2 | 2 |
3 | 7 | 2006.44 | 32 | 14.54 | 2851 | 1327 | 1.64 / 709.83 | 2 | 3 |
4 | 13 | 1664.76 | 24 | 14.53 | 2465 | 860 | 2.50 / 710.69 | 2 | 3 |
5 | 13 | 945.84 | 24 | 14.65 | 1599 | 562 | 3.07 / 711.25 | 2 | 4 |
6 | 13 | 262.56 | 24 | 14.88 | 685 | 245 | 3.31 / 711.50 | 2 | 3 |
7 | 13 | 75.64 | 24 | 14.94 | 414 | 148 | 3.46 / 711.65 | 2 | 3 |
8 | 8 | 0.20 | 165 | 14.94 | 298 | 735 | 4.19 / 712.38 | 2 | 7 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.96 | 35 | 14.91 | 452 | 236 | 0.24 / 704.06 | 2 | 2 |
2 | 12 | 1139.24 | 3 | 14.99 | 1887 | 85 | 0.32 / 704.15 | 2 | 2 |
3 | 7 | 2004.20 | 32 | 14.54 | 2852 | 1327 | 1.65 / 705.47 | 2 | 3 |
4 | 13 | 1662.40 | 24 | 14.52 | 2468 | 860 | 2.51 / 706.33 | 2 | 3 |
5 | 13 | 1117.00 | 24 | 14.59 | 1801 | 631 | 3.14 / 706.96 | 2 | 3 |
6 | 13 | 356.00 | 24 | 14.82 | 839 | 298 | 3.44 / 707.26 | 2 | 5 |
7 | 13 | 92.00 | 24 | 14.92 | 449 | 161 | 3.60 / 707.42 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.92 | 310 | 763 | 4.36 / 708.19 | 2 | 7 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 35 | 14.91 | 433 | 226 | 0.23 / 699.65 | 2 | 2 |
2 | 12 | 1306.80 | 3 | 14.94 | 2105 | 94 | 0.32 / 699.74 | 2 | 2 |
3 | 7 | 2010.64 | 31 | 14.54 | 2870 | 1294 | 1.61 / 701.04 | 2 | 3 |
4 | 13 | 1857.72 | 24 | 14.49 | 2696 | 938 | 2.55 / 701.97 | 2 | 3 |
5 | 13 | 1124.32 | 24 | 14.59 | 1809 | 633 | 3.18 / 702.61 | 2 | 3 |
6 | 13 | 378.36 | 24 | 14.81 | 860 | 306 | 3.49 / 702.91 | 2 | 5 |
7 | 13 | 113.44 | 24 | 14.92 | 470 | 168 | 3.66 / 703.08 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.93 | 302 | 744 | 4.40 / 703.83 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 35 | 14.92 | 435 | 227 | 0.23 / 695.30 | 2 | 2 |
2 | 12 | 1296.04 | 3 | 14.95 | 2100 | 94 | 0.32 / 695.39 | 2 | 2 |
3 | 7 | 2012.80 | 31 | 14.55 | 2864 | 1292 | 1.61 / 696.69 | 2 | 3 |
4 | 13 | 1699.12 | 24 | 14.52 | 2509 | 874 | 2.49 / 697.56 | 2 | 3 |
5 | 13 | 996.16 | 24 | 14.63 | 1662 | 584 | 3.07 / 698.14 | 2 | 4 |
6 | 13 | 310.84 | 24 | 14.85 | 756 | 269 | 3.34 / 698.41 | 2 | 4 |
7 | 13 | 94.24 | 24 | 14.94 | 437 | 157 | 3.50 / 698.57 | 2 | 2 |
8 | 13 | 24.56 | 24 | 14.96 | 337 | 121 | 3.62 / 698.69 | 2 | 2 |
9 | 8 | 0.08 | 165 | 14.93 | 297 | 732 | 4.35 / 699.42 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 35 | 14.93 | 442 | 231 | 0.23 / 690.96 | 2 | 2 |
2 | 12 | 1147.40 | 3 | 15.00 | 1889 | 85 | 0.32 / 691.05 | 2 | 2 |
3 | 7 | 2007.28 | 31 | 14.55 | 2860 | 1290 | 1.61 / 692.34 | 2 | 4 |
4 | 13 | 1697.44 | 24 | 14.52 | 2502 | 872 | 2.48 / 693.21 | 2 | 3 |
5 | 13 | 1143.56 | 24 | 14.59 | 1831 | 641 | 3.12 / 693.85 | 2 | 4 |
6 | 13 | 385.20 | 24 | 14.81 | 870 | 309 | 3.43 / 694.16 | 2 | 5 |
7 | 13 | 112.52 | 24 | 14.92 | 475 | 170 | 3.60 / 694.33 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.93 | 302 | 744 | 4.34 / 695.07 | 2 | 5 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 35 | 14.89 | 454 | 237 | 0.24 / 686.72 | 2 | 2 |
2 | 12 | 1160.36 | 3 | 14.99 | 1907 | 86 | 0.32 / 686.80 | 2 | 2 |
3 | 7 | 2006.72 | 31 | 14.55 | 2859 | 1290 | 1.61 / 688.09 | 2 | 3 |
4 | 13 | 1855.44 | 24 | 14.49 | 2690 | 935 | 2.55 / 689.03 | 2 | 3 |
5 | 13 | 944.80 | 24 | 14.66 | 1592 | 560 | 3.11 / 689.59 | 2 | 4 |
6 | 13 | 281.12 | 24 | 14.88 | 715 | 255 | 3.36 / 689.84 | 2 | 3 |
7 | 13 | 86.72 | 24 | 14.95 | 428 | 154 | 3.52 / 690.00 | 2 | 2 |
8 | 8 | 0.24 | 165 | 14.95 | 298 | 735 | 4.25 / 690.73 | 2 | 7 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 35 | 14.92 | 458 | 239 | 0.24 / 682.37 | 2 | 2 |
2 | 12 | 1148.44 | 3 | 14.99 | 1914 | 86 | 0.33 / 682.46 | 2 | 2 |
3 | 7 | 2008.80 | 31 | 14.55 | 2871 | 1295 | 1.62 / 683.75 | 2 | 4 |
4 | 13 | 1692.12 | 24 | 14.53 | 2497 | 871 | 2.49 / 684.62 | 2 | 4 |
5 | 13 | 869.52 | 24 | 14.68 | 1493 | 526 | 3.02 / 685.15 | 2 | 4 |
6 | 13 | 362.84 | 24 | 14.83 | 836 | 298 | 3.31 / 685.45 | 2 | 5 |
7 | 13 | 97.24 | 24 | 14.93 | 451 | 162 | 3.48 / 685.61 | 2 | 3 |
8 | 13 | 21.48 | 24 | 14.95 | 338 | 121 | 3.60 / 685.73 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.92 | 304 | 748 | 4.35 / 686.48 | 2 | 10 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 35 | 14.92 | 447 | 233 | 0.23 / 678.12 | 2 | 2 |
2 | 12 | 1150.28 | 3 | 14.99 | 1902 | 86 | 0.32 / 678.20 | 2 | 2 |
3 | 7 | 2003.80 | 31 | 14.56 | 2847 | 1285 | 1.60 / 679.49 | 2 | 3 |
4 | 13 | 1710.00 | 24 | 14.52 | 2521 | 879 | 2.48 / 680.37 | 2 | 3 |
5 | 13 | 997.92 | 24 | 14.63 | 1656 | 581 | 3.06 / 680.95 | 2 | 4 |
6 | 13 | 311.72 | 24 | 14.85 | 769 | 274 | 3.34 / 681.22 | 2 | 4 |
7 | 13 | 89.96 | 24 | 14.94 | 442 | 158 | 3.50 / 681.38 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.94 | 305 | 752 | 4.25 / 682.13 | 2 | 5 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 35 | 14.91 | 452 | 236 | 0.24 / 673.77 | 2 | 2 |
2 | 12 | 1158.96 | 3 | 14.99 | 1907 | 86 | 0.32 / 673.85 | 2 | 2 |
3 | 7 | 2007.04 | 31 | 14.56 | 2864 | 1293 | 1.61 / 675.15 | 2 | 3 |
4 | 13 | 1690.84 | 24 | 14.53 | 2494 | 870 | 2.48 / 676.02 | 2 | 3 |
5 | 13 | 999.32 | 24 | 14.64 | 1658 | 583 | 3.07 / 676.60 | 2 | 4 |
6 | 13 | 302.96 | 24 | 14.86 | 755 | 269 | 3.34 / 676.87 | 2 | 4 |
7 | 13 | 94.04 | 24 | 14.94 | 443 | 159 | 3.49 / 677.03 | 2 | 3 |
8 | 13 | 24.88 | 24 | 14.96 | 340 | 122 | 3.62 / 677.15 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.94 | 298 | 735 | 4.35 / 677.88 | 2 | 8 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 35 | 14.91 | 455 | 237 | 0.24 / 669.57 | 2 | 2 |
2 | 12 | 1173.44 | 3 | 14.99 | 1944 | 87 | 0.32 / 669.66 | 2 | 2 |
3 | 7 | 2005.80 | 31 | 14.55 | 2862 | 1291 | 1.62 / 670.95 | 2 | 3 |
4 | 13 | 1717.08 | 24 | 14.52 | 2520 | 878 | 2.49 / 671.83 | 2 | 3 |
5 | 13 | 854.20 | 24 | 14.68 | 1481 | 522 | 3.02 / 672.35 | 2 | 4 |
6 | 13 | 335.84 | 24 | 14.84 | 801 | 285 | 3.30 / 672.64 | 2 | 5 |
7 | 13 | 92.68 | 24 | 14.94 | 440 | 158 | 3.46 / 672.80 | 2 | 3 |
8 | 8 | 0.20 | 165 | 14.94 | 299 | 737 | 4.20 / 673.53 | 2 | 9 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 35 | 14.92 | 452 | 236 | 0.24 / 665.22 | 2 | 2 |
2 | 12 | 1136.04 | 3 | 15.00 | 1878 | 85 | 0.32 / 665.31 | 2 | 2 |
3 | 7 | 2002.96 | 31 | 14.56 | 2856 | 1289 | 1.61 / 666.60 | 2 | 3 |
4 | 13 | 1667.56 | 24 | 14.53 | 2474 | 863 | 2.47 / 667.46 | 2 | 4 |
5 | 13 | 1131.84 | 24 | 14.60 | 1825 | 639 | 3.11 / 668.10 | 2 | 3 |
6 | 13 | 396.48 | 24 | 14.82 | 885 | 315 | 3.43 / 668.42 | 2 | 5 |
7 | 13 | 107.68 | 24 | 14.93 | 468 | 168 | 3.59 / 668.58 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.94 | 306 | 754 | 4.35 / 669.34 | 2 | 6 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 35 | 14.91 | 454 | 237 | 0.24 / 661.04 | 2 | 2 |
2 | 12 | 1146.64 | 3 | 15.00 | 1901 | 86 | 0.32 / 661.12 | 2 | 2 |
3 | 7 | 2015.52 | 31 | 14.55 | 2863 | 1291 | 1.61 / 662.41 | 2 | 3 |
4 | 13 | 1537.32 | 24 | 14.56 | 2321 | 811 | 2.42 / 663.23 | 2 | 3 |
5 | 13 | 1009.76 | 24 | 14.63 | 1670 | 586 | 3.01 / 663.81 | 2 | 4 |
6 | 13 | 304.84 | 24 | 14.86 | 760 | 271 | 3.28 / 664.08 | 2 | 4 |
7 | 13 | 96.36 | 24 | 14.94 | 443 | 159 | 3.44 / 664.24 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.94 | 303 | 747 | 4.19 / 664.99 | 2 | 6 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 35 | 14.93 | 443 | 231 | 0.23 / 656.86 | 2 | 2 |
2 | 12 | 1167.56 | 3 | 14.99 | 1927 | 87 | 0.32 / 656.95 | 2 | 2 |
3 | 7 | 2004.32 | 31 | 14.55 | 2860 | 1290 | 1.61 / 658.24 | 2 | 3 |
4 | 13 | 1675.48 | 24 | 14.53 | 2478 | 864 | 2.47 / 659.10 | 2 | 3 |
5 | 13 | 842.40 | 24 | 14.69 | 1464 | 516 | 2.99 / 659.62 | 2 | 4 |
6 | 13 | 312.12 | 24 | 14.85 | 769 | 274 | 3.26 / 659.89 | 2 | 5 |
7 | 13 | 87.88 | 24 | 14.94 | 436 | 156 | 3.42 / 660.05 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.94 | 305 | 752 | 4.17 / 660.80 | 2 | 8 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 35 | 14.95 | 455 | 238 | 0.24 / 652.62 | 2 | 2 |
2 | 12 | 1166.32 | 3 | 14.97 | 1937 | 87 | 0.33 / 652.70 | 2 | 2 |
3 | 7 | 2002.76 | 31 | 14.54 | 2856 | 1287 | 1.61 / 653.99 | 2 | 4 |
4 | 13 | 1688.88 | 24 | 14.52 | 2495 | 869 | 2.48 / 654.86 | 2 | 4 |
5 | 13 | 1139.36 | 24 | 14.59 | 1835 | 643 | 3.12 / 655.50 | 2 | 4 |
6 | 13 | 254.88 | 24 | 14.89 | 682 | 244 | 3.37 / 655.75 | 2 | 3 |
7 | 13 | 88.24 | 24 | 14.95 | 435 | 156 | 3.52 / 655.90 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.96 | 295 | 728 | 4.25 / 656.63 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 35 | 14.91 | 455 | 237 | 0.24 / 649.21 | 2 | 2 |
2 | 7 | 1095.80 | 32 | 14.91 | 1758 | 839 | 1.08 / 650.05 | 2 | 3 |
3 | 13 | 1095.88 | 24 | 14.84 | 1766 | 629 | 1.71 / 650.67 | 2 | 3 |
4 | 13 | 949.36 | 24 | 14.81 | 1585 | 563 | 2.27 / 651.24 | 2 | 3 |
5 | 13 | 238.88 | 24 | 14.97 | 658 | 236 | 2.50 / 651.47 | 2 | 3 |
6 | 13 | 78.60 | 24 | 15.01 | 421 | 152 | 2.66 / 651.63 | 2 | 3 |
7 | 8 | 0.12 | 165 | 14.99 | 304 | 752 | 3.41 / 652.38 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 35 | 14.95 | 423 | 221 | 0.22 / 644.99 | 2 | 2 |
2 | 12 | 1158.92 | 3 | 15.00 | 1931 | 87 | 0.31 / 645.08 | 2 | 2 |
3 | 7 | 2010.48 | 31 | 14.55 | 2857 | 1289 | 1.60 / 646.37 | 2 | 3 |
4 | 13 | 1691.00 | 24 | 14.53 | 2506 | 874 | 2.47 / 647.24 | 2 | 3 |
5 | 13 | 965.20 | 24 | 14.65 | 1613 | 567 | 3.04 / 647.81 | 2 | 4 |
6 | 13 | 265.20 | 24 | 14.87 | 696 | 248 | 3.29 / 648.06 | 2 | 3 |
7 | 13 | 80.16 | 24 | 14.94 | 430 | 154 | 3.44 / 648.21 | 2 | 2 |
8 | 8 | 0.12 | 165 | 14.93 | 307 | 756 | 4.20 / 648.97 | 2 | 7 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 35 | 14.93 | 438 | 229 | 0.23 / 640.93 | 2 | 2 |
2 | 12 | 1157.92 | 3 | 14.99 | 1916 | 86 | 0.32 / 641.01 | 2 | 2 |
3 | 7 | 2002.52 | 31 | 14.55 | 2844 | 1283 | 1.60 / 642.30 | 2 | 3 |
4 | 13 | 1518.28 | 24 | 14.57 | 2298 | 804 | 2.40 / 643.10 | 2 | 3 |
5 | 13 | 861.60 | 24 | 14.69 | 1489 | 525 | 2.93 / 643.62 | 2 | 3 |
6 | 13 | 207.24 | 24 | 14.91 | 613 | 219 | 3.15 / 643.84 | 2 | 3 |
7 | 13 | 110.96 | 24 | 14.94 | 472 | 169 | 3.31 / 644.01 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.95 | 308 | 760 | 4.07 / 644.77 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 34 | 14.92 | 459 | 233 | 0.23 / 636.71 | 2 | 2 |
2 | 12 | 1140.00 | 3 | 15.00 | 1885 | 85 | 0.32 / 636.80 | 2 | 2 |
3 | 7 | 2004.08 | 31 | 14.56 | 2848 | 1285 | 1.60 / 638.08 | 2 | 3 |
4 | 13 | 1687.56 | 24 | 14.53 | 2494 | 870 | 2.47 / 638.95 | 2 | 4 |
5 | 13 | 991.40 | 24 | 14.65 | 1651 | 580 | 3.05 / 639.53 | 2 | 4 |
6 | 13 | 301.24 | 24 | 14.87 | 747 | 267 | 3.32 / 639.80 | 2 | 3 |
7 | 13 | 102.48 | 24 | 14.95 | 449 | 161 | 3.48 / 639.96 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.96 | 298 | 736 | 4.22 / 640.70 | 2 | 7 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 35 | 14.94 | 443 | 232 | 0.23 / 632.53 | 2 | 2 |
2 | 12 | 1135.52 | 3 | 15.00 | 1901 | 86 | 0.32 / 632.61 | 2 | 2 |
3 | 7 | 2004.68 | 31 | 14.56 | 2852 | 1287 | 1.60 / 633.90 | 2 | 3 |
4 | 13 | 1685.64 | 24 | 14.53 | 2497 | 871 | 2.48 / 634.77 | 2 | 3 |
5 | 13 | 835.28 | 24 | 14.70 | 1449 | 511 | 2.99 / 635.28 | 2 | 5 |
6 | 13 | 322.60 | 24 | 14.86 | 784 | 280 | 3.27 / 635.56 | 2 | 4 |
7 | 13 | 90.60 | 24 | 14.95 | 444 | 159 | 3.43 / 635.72 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.95 | 308 | 760 | 4.19 / 636.48 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 35 | 14.95 | 444 | 232 | 0.23 / 628.27 | 2 | 2 |
2 | 12 | 1139.52 | 3 | 15.02 | 1872 | 84 | 0.32 / 628.35 | 2 | 2 |
3 | 7 | 2008.84 | 31 | 14.57 | 2856 | 1290 | 1.61 / 629.64 | 2 | 3 |
4 | 13 | 1854.68 | 24 | 14.50 | 2679 | 932 | 2.54 / 630.57 | 2 | 3 |
5 | 13 | 966.96 | 24 | 14.67 | 1614 | 568 | 3.11 / 631.14 | 2 | 4 |
6 | 13 | 272.88 | 24 | 14.89 | 705 | 252 | 3.36 / 631.39 | 2 | 3 |
7 | 13 | 93.84 | 24 | 14.96 | 441 | 158 | 3.52 / 631.55 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.96 | 301 | 743 | 4.26 / 632.30 | 2 | 9 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 35 | 14.94 | 456 | 238 | 0.24 / 624.02 | 2 | 2 |
2 | 12 | 1162.04 | 3 | 15.00 | 1920 | 86 | 0.32 / 624.10 | 2 | 2 |
3 | 7 | 2004.60 | 31 | 14.56 | 2850 | 1286 | 1.61 / 625.39 | 2 | 3 |
4 | 13 | 1860.76 | 24 | 14.50 | 2693 | 937 | 2.55 / 626.33 | 2 | 3 |
5 | 13 | 964.48 | 24 | 14.66 | 1611 | 567 | 3.12 / 626.89 | 2 | 4 |
6 | 13 | 268.16 | 24 | 14.89 | 695 | 248 | 3.36 / 627.14 | 2 | 3 |
7 | 13 | 103.36 | 24 | 14.96 | 449 | 161 | 3.52 / 627.30 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.97 | 296 | 731 | 4.26 / 628.04 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 35 | 14.93 | 451 | 236 | 0.24 / 619.81 | 2 | 2 |
2 | 12 | 1164.88 | 3 | 15.00 | 1917 | 86 | 0.32 / 619.89 | 2 | 2 |
3 | 7 | 2006.40 | 31 | 14.57 | 2857 | 1290 | 1.61 / 621.18 | 2 | 3 |
4 | 13 | 1684.48 | 24 | 14.55 | 2497 | 872 | 2.48 / 622.06 | 2 | 4 |
5 | 13 | 982.60 | 24 | 14.66 | 1639 | 577 | 3.06 / 622.63 | 2 | 4 |
6 | 13 | 290.32 | 24 | 14.88 | 736 | 263 | 3.32 / 622.90 | 2 | 4 |
7 | 13 | 83.48 | 24 | 14.96 | 428 | 154 | 3.48 / 623.05 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.96 | 296 | 731 | 4.21 / 623.78 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 35 | 14.94 | 451 | 236 | 0.24 / 615.45 | 2 | 2 |
2 | 12 | 1142.96 | 3 | 15.00 | 1892 | 85 | 0.32 / 615.53 | 2 | 2 |
3 | 7 | 2008.20 | 31 | 14.57 | 2853 | 1289 | 1.61 / 616.82 | 2 | 3 |
4 | 13 | 1702.32 | 24 | 14.54 | 2504 | 874 | 2.48 / 617.69 | 2 | 3 |
5 | 13 | 1001.56 | 24 | 14.65 | 1662 | 584 | 3.07 / 618.28 | 2 | 4 |
6 | 13 | 300.16 | 24 | 14.88 | 753 | 269 | 3.34 / 618.55 | 2 | 4 |
7 | 13 | 87.68 | 24 | 14.96 | 435 | 156 | 3.49 / 618.70 | 2 | 3 |
8 | 13 | 23.84 | 24 | 14.98 | 341 | 123 | 3.62 / 618.83 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.95 | 302 | 745 | 4.36 / 619.57 | 2 | 7 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 35 | 14.93 | 451 | 236 | 0.24 / 611.19 | 2 | 2 |
2 | 12 | 1308.52 | 3 | 14.93 | 2119 | 95 | 0.33 / 611.28 | 2 | 2 |
3 | 7 | 2009.36 | 31 | 14.56 | 2855 | 1289 | 1.62 / 612.57 | 2 | 3 |
4 | 13 | 1698.24 | 24 | 14.53 | 2511 | 876 | 2.49 / 613.45 | 2 | 3 |
5 | 13 | 1001.20 | 24 | 14.65 | 1669 | 587 | 3.08 / 614.03 | 2 | 3 |
6 | 13 | 296.76 | 24 | 14.88 | 745 | 266 | 3.35 / 614.30 | 2 | 4 |
7 | 13 | 95.28 | 24 | 14.96 | 446 | 160 | 3.51 / 614.46 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.96 | 304 | 750 | 4.26 / 615.21 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 35 | 14.95 | 454 | 238 | 0.24 / 607.03 | 2 | 2 |
2 | 12 | 1289.88 | 3 | 14.93 | 2097 | 94 | 0.33 / 607.13 | 2 | 2 |
3 | 7 | 1940.88 | 31 | 14.56 | 2793 | 1261 | 1.59 / 608.39 | 2 | 3 |
4 | 13 | 1630.96 | 24 | 14.55 | 2441 | 852 | 2.44 / 609.24 | 2 | 3 |
5 | 13 | 946.64 | 24 | 14.66 | 1601 | 563 | 3.01 / 609.80 | 2 | 3 |
6 | 13 | 242.44 | 24 | 14.90 | 663 | 237 | 3.24 / 610.04 | 2 | 3 |
7 | 13 | 89.08 | 24 | 14.96 | 434 | 156 | 3.40 / 610.20 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.96 | 306 | 755 | 4.16 / 610.95 | 2 | 5 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 34 | 14.93 | 441 | 224 | 0.22 / 603.27 | 2 | 2 |
2 | 12 | 1149.68 | 3 | 15.01 | 1905 | 86 | 0.31 / 603.35 | 2 | 2 |
3 | 7 | 1393.64 | 32 | 14.78 | 2133 | 1009 | 1.32 / 604.36 | 2 | 3 |
4 | 13 | 1317.28 | 24 | 14.72 | 2055 | 726 | 2.04 / 605.09 | 2 | 3 |
5 | 13 | 965.16 | 24 | 14.74 | 1619 | 573 | 2.62 / 605.66 | 2 | 3 |
6 | 13 | 226.16 | 24 | 14.95 | 643 | 231 | 2.85 / 605.89 | 2 | 3 |
7 | 13 | 88.92 | 24 | 14.99 | 432 | 155 | 3.00 / 606.05 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.98 | 303 | 749 | 3.75 / 606.80 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 34 | 14.93 | 446 | 226 | 0.23 / 599.06 | 2 | 2 |
2 | 12 | 1151.72 | 3 | 15.00 | 1900 | 85 | 0.31 / 599.15 | 2 | 2 |
3 | 7 | 1775.36 | 32 | 14.63 | 2597 | 1216 | 1.53 / 600.37 | 2 | 3 |
4 | 13 | 1656.24 | 24 | 14.58 | 2448 | 857 | 2.38 / 601.22 | 2 | 3 |
5 | 13 | 819.96 | 24 | 14.73 | 1441 | 509 | 2.89 / 601.73 | 2 | 5 |
6 | 13 | 297.96 | 24 | 14.89 | 756 | 270 | 3.16 / 602.00 | 2 | 4 |
7 | 13 | 78.20 | 24 | 14.97 | 427 | 153 | 3.32 / 602.15 | 2 | 3 |
8 | 13 | 42.92 | 24 | 14.97 | 376 | 135 | 3.45 / 602.29 | 2 | 3 |
9 | 8 | 0.08 | 165 | 14.95 | 306 | 755 | 4.21 / 603.04 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 34 | 14.93 | 446 | 226 | 0.23 / 594.73 | 2 | 2 |
2 | 12 | 1140.76 | 3 | 15.01 | 1896 | 85 | 0.31 / 594.82 | 2 | 2 |
3 | 7 | 2002.48 | 31 | 14.57 | 2860 | 1292 | 1.60 / 596.11 | 2 | 3 |
4 | 13 | 1686.48 | 24 | 14.55 | 2496 | 872 | 2.48 / 596.98 | 2 | 3 |
5 | 13 | 961.80 | 24 | 14.68 | 1611 | 568 | 3.04 / 597.55 | 2 | 4 |
6 | 13 | 276.44 | 24 | 14.90 | 710 | 254 | 3.30 / 597.80 | 2 | 3 |
7 | 13 | 81.28 | 24 | 14.97 | 427 | 153 | 3.45 / 597.96 | 2 | 3 |
8 | 13 | 22.72 | 24 | 14.98 | 343 | 123 | 3.57 / 598.08 | 2 | 3 |
9 | 8 | 0.12 | 165 | 14.95 | 307 | 757 | 4.33 / 598.84 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 34 | 14.93 | 454 | 230 | 0.23 / 590.45 | 2 | 2 |
2 | 12 | 1155.08 | 3 | 15.01 | 1911 | 86 | 0.32 / 590.53 | 2 | 2 |
3 | 7 | 2001.96 | 31 | 14.56 | 2855 | 1289 | 1.61 / 591.82 | 2 | 3 |
4 | 13 | 1502.76 | 24 | 14.58 | 2287 | 800 | 2.41 / 592.62 | 2 | 4 |
5 | 13 | 1007.04 | 24 | 14.65 | 1671 | 588 | 2.99 / 593.21 | 2 | 4 |
6 | 13 | 264.28 | 24 | 14.90 | 703 | 251 | 3.24 / 593.46 | 2 | 3 |
7 | 13 | 87.32 | 24 | 14.96 | 439 | 158 | 3.40 / 593.62 | 2 | 3 |
8 | 13 | 51.20 | 24 | 14.97 | 381 | 137 | 3.54 / 593.75 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.95 | 305 | 752 | 4.29 / 594.51 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 34 | 14.92 | 446 | 226 | 0.23 / 586.26 | 2 | 2 |
2 | 12 | 1154.44 | 3 | 15.01 | 1930 | 87 | 0.31 / 586.35 | 2 | 2 |
3 | 7 | 1797.76 | 32 | 14.63 | 2618 | 1226 | 1.54 / 587.58 | 2 | 3 |
4 | 13 | 1658.84 | 24 | 14.58 | 2462 | 862 | 2.40 / 588.44 | 2 | 4 |
5 | 13 | 925.64 | 24 | 14.70 | 1574 | 555 | 2.96 / 588.99 | 2 | 4 |
6 | 13 | 370.44 | 24 | 14.86 | 853 | 304 | 3.26 / 589.30 | 2 | 5 |
7 | 13 | 91.92 | 24 | 14.96 | 450 | 162 | 3.42 / 589.46 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.96 | 307 | 758 | 4.18 / 590.22 | 2 | 5 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 34 | 14.94 | 447 | 227 | 0.23 / 581.94 | 2 | 2 |
2 | 12 | 1152.44 | 3 | 15.00 | 1908 | 86 | 0.31 / 582.03 | 2 | 2 |
3 | 7 | 2012.00 | 32 | 14.56 | 2865 | 1335 | 1.65 / 583.36 | 2 | 3 |
4 | 13 | 1543.20 | 24 | 14.57 | 2323 | 812 | 2.46 / 584.18 | 2 | 4 |
5 | 13 | 880.92 | 24 | 14.69 | 1512 | 533 | 2.99 / 584.71 | 2 | 4 |
6 | 13 | 339.44 | 24 | 14.86 | 808 | 288 | 3.28 / 585.00 | 2 | 4 |
7 | 13 | 82.76 | 24 | 14.96 | 435 | 156 | 3.44 / 585.15 | 2 | 3 |
8 | 13 | 20.52 | 24 | 14.97 | 343 | 123 | 3.56 / 585.28 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.94 | 308 | 759 | 4.32 / 586.04 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 34 | 14.93 | 443 | 225 | 0.22 / 577.64 | 2 | 2 |
2 | 12 | 1298.52 | 3 | 14.96 | 2108 | 95 | 0.32 / 577.73 | 2 | 2 |
3 | 7 | 2003.28 | 32 | 14.57 | 2853 | 1330 | 1.65 / 579.06 | 2 | 3 |
4 | 13 | 1702.04 | 24 | 14.54 | 2508 | 875 | 2.52 / 579.94 | 2 | 3 |
5 | 13 | 880.60 | 24 | 14.69 | 1514 | 534 | 3.06 / 580.47 | 2 | 5 |
6 | 13 | 219.16 | 24 | 14.92 | 636 | 228 | 3.29 / 580.70 | 2 | 3 |
7 | 13 | 74.00 | 24 | 14.98 | 409 | 147 | 3.43 / 580.85 | 2 | 2 |
8 | 13 | 16.44 | 24 | 14.99 | 329 | 118 | 3.55 / 580.97 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.96 | 304 | 750 | 4.30 / 581.72 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 34 | 14.93 | 446 | 226 | 0.23 / 573.16 | 2 | 2 |
2 | 12 | 1146.36 | 3 | 15.00 | 1899 | 85 | 0.31 / 573.25 | 2 | 2 |
3 | 7 | 2004.36 | 31 | 14.57 | 2858 | 1291 | 1.60 / 574.54 | 2 | 3 |
4 | 13 | 1850.80 | 24 | 14.51 | 2680 | 933 | 2.54 / 575.47 | 2 | 3 |
5 | 13 | 1092.28 | 24 | 14.63 | 1777 | 624 | 3.16 / 576.09 | 2 | 3 |
6 | 13 | 342.28 | 24 | 14.86 | 807 | 288 | 3.45 / 576.38 | 2 | 4 |
7 | 13 | 97.64 | 24 | 14.96 | 451 | 162 | 3.61 / 576.54 | 2 | 3 |
8 | 13 | 28.56 | 24 | 14.98 | 349 | 125 | 3.74 / 576.67 | 2 | 3 |
9 | 8 | 0.12 | 165 | 14.95 | 302 | 745 | 4.48 / 577.41 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 34 | 14.94 | 437 | 222 | 0.22 / 569.13 | 2 | 2 |
2 | 12 | 1146.44 | 3 | 15.01 | 1890 | 85 | 0.31 / 569.22 | 2 | 2 |
3 | 7 | 1646.24 | 31 | 14.69 | 2436 | 1109 | 1.42 / 570.33 | 2 | 3 |
4 | 13 | 1501.48 | 24 | 14.65 | 2268 | 797 | 2.21 / 571.13 | 2 | 3 |
5 | 13 | 805.76 | 24 | 14.76 | 1424 | 504 | 2.72 / 571.63 | 2 | 4 |
6 | 13 | 280.56 | 24 | 14.90 | 728 | 260 | 2.98 / 571.89 | 2 | 3 |
7 | 13 | 81.88 | 24 | 14.97 | 435 | 156 | 3.13 / 572.05 | 2 | 3 |
8 | 13 | 46.28 | 24 | 14.98 | 375 | 135 | 3.27 / 572.18 | 2 | 3 |
9 | 8 | -0.04 | 165 | 14.95 | 305 | 752 | 4.02 / 572.93 | 2 | 6 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 34 | 14.95 | 432 | 220 | 0.22 / 564.79 | 2 | 2 |
2 | 12 | 1140.60 | 3 | 15.01 | 1900 | 86 | 0.31 / 564.87 | 2 | 2 |
3 | 7 | 2004.28 | 31 | 14.57 | 2853 | 1289 | 1.59 / 566.16 | 2 | 3 |
4 | 13 | 1701.88 | 24 | 14.54 | 2515 | 878 | 2.47 / 567.04 | 2 | 3 |
5 | 13 | 987.64 | 24 | 14.65 | 1651 | 580 | 3.05 / 567.62 | 2 | 4 |
6 | 13 | 272.28 | 24 | 14.89 | 709 | 253 | 3.31 / 567.87 | 2 | 3 |
7 | 13 | 93.48 | 24 | 14.96 | 444 | 159 | 3.46 / 568.03 | 2 | 3 |
8 | 13 | 51.72 | 24 | 14.97 | 378 | 136 | 3.60 / 568.17 | 2 | 3 |
9 | 8 | 0.08 | 165 | 14.95 | 301 | 742 | 4.34 / 568.91 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 34 | 14.96 | 460 | 234 | 0.23 / 560.37 | 2 | 2 |
2 | 12 | 1141.24 | 3 | 15.00 | 1892 | 85 | 0.32 / 560.46 | 2 | 2 |
3 | 7 | 2003.56 | 31 | 14.56 | 2857 | 1290 | 1.61 / 561.74 | 2 | 3 |
4 | 13 | 1681.28 | 24 | 14.54 | 2491 | 869 | 2.48 / 562.61 | 2 | 3 |
5 | 13 | 976.44 | 24 | 14.66 | 1636 | 576 | 3.05 / 563.19 | 2 | 4 |
6 | 13 | 416.68 | 24 | 14.83 | 916 | 326 | 3.38 / 563.52 | 2 | 6 |
7 | 13 | 109.24 | 24 | 14.95 | 475 | 170 | 3.55 / 563.69 | 2 | 3 |
8 | 13 | 24.60 | 24 | 14.98 | 350 | 126 | 3.68 / 563.81 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.95 | 307 | 757 | 4.43 / 564.57 | 2 | 9 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 34 | 14.93 | 445 | 226 | 0.23 / 556.85 | 2 | 2 |
2 | 12 | 1245.32 | 3 | 14.97 | 2031 | 91 | 0.32 / 556.94 | 2 | 2 |
3 | 7 | 1245.68 | 31 | 14.85 | 1946 | 896 | 1.21 / 557.84 | 2 | 3 |
4 | 13 | 1213.84 | 24 | 14.78 | 1925 | 683 | 1.90 / 558.52 | 2 | 3 |
5 | 13 | 751.96 | 24 | 14.84 | 1352 | 482 | 2.38 / 559.00 | 2 | 3 |
6 | 13 | 230.36 | 24 | 14.97 | 650 | 234 | 2.61 / 559.23 | 2 | 3 |
7 | 13 | 66.08 | 24 | 15.02 | 409 | 147 | 2.76 / 559.38 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.00 | 305 | 755 | 3.51 / 560.14 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 34 | 14.94 | 442 | 225 | 0.22 / 552.49 | 2 | 2 |
2 | 12 | 1145.96 | 3 | 15.01 | 1884 | 85 | 0.31 / 552.57 | 2 | 2 |
3 | 7 | 2006.92 | 31 | 14.58 | 2850 | 1288 | 1.60 / 553.86 | 2 | 3 |
4 | 13 | 1705.92 | 24 | 14.55 | 2521 | 880 | 2.48 / 554.74 | 2 | 3 |
5 | 13 | 986.40 | 24 | 14.67 | 1652 | 582 | 3.06 / 555.32 | 2 | 4 |
6 | 13 | 295.16 | 24 | 14.89 | 745 | 266 | 3.33 / 555.59 | 2 | 3 |
7 | 13 | 85.84 | 24 | 14.97 | 437 | 157 | 3.48 / 555.74 | 2 | 3 |
8 | 13 | 22.64 | 24 | 14.99 | 340 | 122 | 3.61 / 555.87 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.95 | 307 | 757 | 4.36 / 556.62 | 2 | 8 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 34 | 14.93 | 444 | 225 | 0.23 / 548.08 | 2 | 2 |
2 | 12 | 1143.96 | 3 | 15.02 | 1893 | 85 | 0.31 / 548.16 | 2 | 2 |
3 | 7 | 2002.92 | 31 | 14.59 | 2852 | 1290 | 1.60 / 549.45 | 2 | 4 |
4 | 13 | 1700.76 | 24 | 14.55 | 2512 | 877 | 2.48 / 550.33 | 2 | 3 |
5 | 13 | 1164.40 | 24 | 14.62 | 1861 | 653 | 3.13 / 550.98 | 2 | 3 |
6 | 13 | 266.52 | 24 | 14.91 | 701 | 251 | 3.38 / 551.23 | 2 | 3 |
7 | 13 | 84.56 | 24 | 14.98 | 437 | 157 | 3.54 / 551.39 | 2 | 3 |
8 | 13 | 22.60 | 24 | 14.99 | 343 | 123 | 3.66 / 551.51 | 2 | 2 |
9 | 8 | 0.08 | 165 | 14.97 | 303 | 748 | 4.41 / 552.26 | 2 | 9 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 34 | 14.94 | 450 | 229 | 0.23 / 543.65 | 2 | 2 |
2 | 12 | 1158.64 | 3 | 15.02 | 1901 | 86 | 0.31 / 543.73 | 2 | 2 |
3 | 7 | 2003.16 | 31 | 14.58 | 2850 | 1288 | 1.60 / 545.02 | 2 | 3 |
4 | 13 | 1675.44 | 24 | 14.56 | 2479 | 866 | 2.47 / 545.89 | 2 | 3 |
5 | 13 | 1104.72 | 24 | 14.64 | 1792 | 630 | 3.10 / 546.52 | 2 | 3 |
6 | 13 | 344.12 | 24 | 14.88 | 814 | 291 | 3.39 / 546.81 | 2 | 5 |
7 | 13 | 92.32 | 24 | 14.97 | 449 | 161 | 3.55 / 546.97 | 2 | 3 |
8 | 13 | 24.44 | 24 | 14.98 | 351 | 126 | 3.68 / 547.09 | 2 | 3 |
9 | 8 | 0.12 | 165 | 14.96 | 306 | 755 | 4.43 / 547.85 | 2 | 9 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 34 | 14.94 | 440 | 224 | 0.22 / 539.44 | 2 | 2 |
2 | 12 | 1166.04 | 3 | 15.02 | 1914 | 86 | 0.31 / 539.53 | 2 | 2 |
3 | 7 | 2008.80 | 31 | 14.58 | 2864 | 1294 | 1.60 / 540.82 | 2 | 3 |
4 | 13 | 1685.84 | 24 | 14.55 | 2500 | 873 | 2.48 / 541.70 | 2 | 3 |
5 | 13 | 959.60 | 24 | 14.68 | 1609 | 567 | 3.04 / 542.26 | 2 | 4 |
6 | 13 | 251.84 | 24 | 14.92 | 684 | 245 | 3.29 / 542.51 | 2 | 3 |
7 | 13 | 75.08 | 24 | 14.98 | 423 | 152 | 3.44 / 542.66 | 2 | 3 |
8 | 8 | 0.20 | 165 | 14.97 | 307 | 758 | 4.20 / 543.42 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 34 | 14.95 | 444 | 226 | 0.23 / 535.20 | 2 | 2 |
2 | 12 | 1132.96 | 3 | 15.02 | 1879 | 85 | 0.31 / 535.28 | 2 | 2 |
3 | 7 | 2007.76 | 32 | 14.57 | 2868 | 1337 | 1.65 / 536.62 | 2 | 3 |
4 | 13 | 1679.84 | 24 | 14.56 | 2481 | 867 | 2.51 / 537.49 | 2 | 3 |
5 | 13 | 961.48 | 24 | 14.68 | 1613 | 568 | 3.08 / 538.06 | 2 | 3 |
6 | 13 | 268.72 | 24 | 14.90 | 712 | 255 | 3.34 / 538.31 | 2 | 4 |
7 | 13 | 78.40 | 24 | 14.98 | 426 | 153 | 3.49 / 538.46 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.97 | 306 | 756 | 4.25 / 539.22 | 2 | 8 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 34 | 14.94 | 444 | 226 | 0.23 / 530.99 | 2 | 2 |
2 | 12 | 1146.40 | 3 | 15.02 | 1901 | 86 | 0.31 / 531.07 | 2 | 2 |
3 | 7 | 2004.24 | 31 | 14.58 | 2852 | 1289 | 1.60 / 532.36 | 2 | 4 |
4 | 13 | 1687.08 | 24 | 14.56 | 2498 | 873 | 2.47 / 533.24 | 2 | 3 |
5 | 13 | 973.84 | 24 | 14.68 | 1629 | 574 | 3.05 / 533.81 | 2 | 4 |
6 | 13 | 267.56 | 24 | 14.91 | 706 | 253 | 3.30 / 534.06 | 2 | 4 |
7 | 13 | 88.60 | 24 | 14.98 | 438 | 157 | 3.46 / 534.22 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.98 | 304 | 751 | 4.21 / 534.97 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 34 | 14.94 | 448 | 228 | 0.23 / 526.89 | 2 | 2 |
2 | 12 | 1142.28 | 3 | 15.01 | 1905 | 86 | 0.31 / 526.98 | 2 | 2 |
3 | 7 | 2002.88 | 31 | 14.59 | 2863 | 1295 | 1.61 / 528.27 | 2 | 3 |
4 | 13 | 1543.72 | 24 | 14.58 | 2326 | 814 | 2.42 / 529.09 | 2 | 3 |
5 | 13 | 880.48 | 24 | 14.71 | 1510 | 533 | 2.96 / 529.62 | 2 | 3 |
6 | 13 | 233.84 | 24 | 14.93 | 652 | 234 | 3.19 / 529.85 | 2 | 3 |
7 | 13 | 73.40 | 24 | 14.98 | 419 | 151 | 3.34 / 530.00 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.97 | 308 | 761 | 4.10 / 530.76 | 2 | 5 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 34 | 14.95 | 446 | 227 | 0.23 / 522.71 | 2 | 2 |
2 | 12 | 1147.28 | 3 | 15.02 | 1917 | 86 | 0.31 / 522.80 | 2 | 2 |
3 | 7 | 2002.16 | 31 | 14.57 | 2864 | 1294 | 1.61 / 524.09 | 2 | 3 |
4 | 13 | 1530.72 | 24 | 14.58 | 2313 | 809 | 2.42 / 524.90 | 2 | 3 |
5 | 13 | 1004.72 | 24 | 14.66 | 1674 | 589 | 3.01 / 525.49 | 2 | 4 |
6 | 13 | 266.28 | 24 | 14.90 | 709 | 254 | 3.26 / 525.74 | 2 | 3 |
7 | 13 | 80.40 | 24 | 14.97 | 434 | 156 | 3.41 / 525.90 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.97 | 309 | 763 | 4.18 / 526.66 | 2 | 6 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 34 | 14.94 | 442 | 225 | 0.22 / 518.63 | 2 | 2 |
2 | 12 | 1148.28 | 3 | 15.02 | 1897 | 85 | 0.31 / 518.72 | 2 | 2 |
3 | 7 | 2007.32 | 31 | 14.57 | 2850 | 1287 | 1.60 / 520.00 | 2 | 3 |
4 | 13 | 1540.20 | 24 | 14.59 | 2326 | 814 | 2.41 / 520.82 | 2 | 4 |
5 | 13 | 883.76 | 24 | 14.70 | 1524 | 538 | 2.95 / 521.36 | 2 | 4 |
6 | 13 | 215.80 | 24 | 14.94 | 627 | 225 | 3.17 / 521.58 | 2 | 3 |
7 | 13 | 70.88 | 24 | 14.99 | 418 | 150 | 3.32 / 521.73 | 2 | 2 |
8 | 8 | 0.04 | 165 | 14.98 | 305 | 754 | 4.08 / 522.49 | 2 | 8 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 34 | 14.96 | 450 | 229 | 0.23 / 514.40 | 2 | 2 |
2 | 12 | 1148.24 | 3 | 15.03 | 1883 | 85 | 0.31 / 514.49 | 2 | 2 |
3 | 7 | 2010.44 | 32 | 14.57 | 2856 | 1332 | 1.65 / 515.82 | 2 | 3 |
4 | 13 | 1690.20 | 24 | 14.56 | 2504 | 875 | 2.52 / 516.70 | 2 | 3 |
5 | 13 | 857.52 | 24 | 14.72 | 1486 | 525 | 3.05 / 517.22 | 2 | 3 |
6 | 13 | 324.32 | 24 | 14.88 | 789 | 282 | 3.33 / 517.50 | 2 | 4 |
7 | 13 | 80.00 | 24 | 14.98 | 428 | 154 | 3.48 / 517.66 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.97 | 304 | 751 | 4.23 / 518.41 | 2 | 6 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 34 | 14.94 | 452 | 230 | 0.23 / 510.17 | 2 | 2 |
2 | 12 | 1147.92 | 3 | 15.03 | 1926 | 87 | 0.32 / 510.25 | 2 | 2 |
3 | 7 | 2007.32 | 32 | 14.58 | 2865 | 1337 | 1.65 / 511.59 | 2 | 3 |
4 | 13 | 1679.76 | 24 | 14.56 | 2489 | 870 | 2.52 / 512.46 | 2 | 3 |
5 | 13 | 952.56 | 24 | 14.69 | 1610 | 568 | 3.09 / 513.03 | 2 | 4 |
6 | 13 | 253.32 | 24 | 14.92 | 685 | 245 | 3.34 / 513.27 | 2 | 3 |
7 | 13 | 83.84 | 24 | 14.98 | 431 | 155 | 3.49 / 513.43 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.98 | 302 | 746 | 4.24 / 514.18 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 34 | 14.96 | 454 | 231 | 0.23 / 505.93 | 2 | 2 |
2 | 3 | 1018.20 | 1 | 15.07 | 1728 | 26 | 0.26 / 505.96 | 2 | 3 |
3 | 12 | 1135.60 | 3 | 15.02 | 1872 | 84 | 0.34 / 506.04 | 2 | 2 |
4 | 7 | 2001.88 | 31 | 14.58 | 2858 | 1292 | 1.63 / 507.33 | 2 | 3 |
5 | 13 | 1542.08 | 24 | 14.58 | 2328 | 815 | 2.45 / 508.15 | 2 | 4 |
6 | 13 | 1022.20 | 24 | 14.66 | 1692 | 595 | 3.04 / 508.74 | 2 | 5 |
7 | 13 | 307.44 | 24 | 14.89 | 768 | 274 | 3.32 / 509.02 | 2 | 3 |
8 | 13 | 80.12 | 24 | 14.97 | 433 | 156 | 3.47 / 509.17 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.97 | 310 | 766 | 4.24 / 509.94 | 2 | 9 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 34 | 14.96 | 447 | 227 | 0.23 / 502.14 | 2 | 2 |
2 | 12 | 1151.84 | 3 | 15.02 | 1914 | 86 | 0.31 / 502.23 | 2 | 2 |
3 | 7 | 1557.24 | 31 | 14.74 | 2335 | 1067 | 1.38 / 503.30 | 2 | 3 |
4 | 13 | 1416.60 | 24 | 14.70 | 2168 | 765 | 2.15 / 504.06 | 2 | 3 |
5 | 13 | 773.16 | 24 | 14.80 | 1378 | 489 | 2.63 / 504.55 | 2 | 6 |
6 | 13 | 251.92 | 24 | 14.95 | 686 | 246 | 2.88 / 504.80 | 2 | 3 |
7 | 13 | 76.80 | 24 | 15.00 | 422 | 152 | 3.03 / 504.95 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.99 | 303 | 749 | 3.78 / 505.70 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 34 | 14.94 | 454 | 231 | 0.23 / 497.95 | 2 | 2 |
2 | 12 | 1152.56 | 3 | 15.04 | 1906 | 86 | 0.32 / 498.04 | 2 | 2 |
3 | 7 | 2002.64 | 31 | 14.59 | 2855 | 1291 | 1.61 / 499.33 | 2 | 3 |
4 | 13 | 1680.64 | 24 | 14.58 | 2501 | 875 | 2.48 / 500.20 | 2 | 3 |
5 | 13 | 963.72 | 24 | 14.70 | 1619 | 571 | 3.05 / 500.77 | 2 | 4 |
6 | 13 | 247.88 | 24 | 14.93 | 682 | 244 | 3.30 / 501.02 | 2 | 3 |
7 | 13 | 94.28 | 24 | 14.99 | 447 | 161 | 3.46 / 501.18 | 2 | 3 |
8 | 8 | 0.16 | 165 | 14.99 | 298 | 737 | 4.20 / 501.92 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 34 | 14.95 | 447 | 227 | 0.23 / 492.38 | 2 | 2 |
2 | 12 | 1163.96 | 3 | 15.02 | 1908 | 86 | 0.31 / 492.46 | 2 | 2 |
3 | 7 | 1951.72 | 31 | 14.59 | 2805 | 1269 | 1.58 / 493.73 | 2 | 3 |
4 | 13 | 1952.08 | 24 | 14.49 | 2820 | 981 | 2.56 / 494.71 | 2 | 4 |
5 | 13 | 1952.08 | 24 | 14.39 | 2814 | 972 | 3.53 / 495.68 | 2 | 4 |
6 | 13 | 1952.12 | 24 | 14.31 | 2807 | 964 | 4.50 / 496.65 | 2 | 4 |
7 | 13 | 115.80 | 24 | 14.96 | 483 | 173 | 4.67 / 496.82 | 2 | 3 |
8 | 13 | 32.40 | 24 | 14.99 | 367 | 132 | 4.80 / 496.95 | 2 | 3 |
9 | 8 | 0.08 | 165 | 14.96 | 311 | 768 | 5.57 / 497.72 | 2 | 8 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 34 | 14.95 | 442 | 225 | 0.22 / 488.32 | 2 | 2 |
2 | 12 | 1125.64 | 3 | 15.04 | 1866 | 84 | 0.31 / 488.41 | 2 | 2 |
3 | 7 | 1774.24 | 32 | 14.65 | 2596 | 1217 | 1.53 / 489.62 | 2 | 3 |
4 | 13 | 1627.68 | 24 | 14.61 | 2433 | 853 | 2.38 / 490.48 | 2 | 3 |
5 | 13 | 784.08 | 24 | 14.77 | 1392 | 493 | 2.87 / 490.97 | 2 | 6 |
6 | 13 | 262.96 | 24 | 14.93 | 700 | 251 | 3.12 / 491.22 | 2 | 3 |
7 | 13 | 93.52 | 24 | 14.99 | 448 | 161 | 3.28 / 491.38 | 2 | 3 |
8 | 8 | 0.20 | 165 | 14.98 | 310 | 766 | 4.05 / 492.15 | 2 | 9 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 34 | 14.95 | 447 | 227 | 0.23 / 484.14 | 2 | 2 |
2 | 12 | 1143.00 | 3 | 15.03 | 1894 | 85 | 0.31 / 484.22 | 2 | 2 |
3 | 7 | 2003.96 | 31 | 14.58 | 2859 | 1292 | 1.60 / 485.51 | 2 | 4 |
4 | 13 | 1526.32 | 24 | 14.60 | 2308 | 809 | 2.41 / 486.32 | 2 | 3 |
5 | 13 | 1000.76 | 24 | 14.68 | 1661 | 585 | 3.00 / 486.91 | 2 | 4 |
6 | 13 | 294.64 | 24 | 14.90 | 746 | 267 | 3.27 / 487.17 | 2 | 3 |
7 | 13 | 77.56 | 24 | 14.98 | 427 | 154 | 3.42 / 487.33 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.97 | 312 | 771 | 4.19 / 488.10 | 2 | 7 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 34 | 14.95 | 455 | 231 | 0.23 / 479.93 | 2 | 2 |
2 | 12 | 1136.76 | 3 | 15.03 | 1883 | 85 | 0.32 / 480.01 | 2 | 2 |
3 | 7 | 2009.64 | 31 | 14.58 | 2871 | 1298 | 1.61 / 481.31 | 2 | 3 |
4 | 13 | 1694.96 | 24 | 14.56 | 2505 | 875 | 2.49 / 482.18 | 2 | 3 |
5 | 13 | 966.36 | 24 | 14.69 | 1617 | 570 | 3.06 / 482.75 | 2 | 4 |
6 | 13 | 262.20 | 24 | 14.92 | 697 | 250 | 3.31 / 483.00 | 2 | 3 |
7 | 13 | 82.96 | 24 | 14.99 | 428 | 154 | 3.46 / 483.16 | 2 | 3 |
8 | 8 | 0.00 | 165 | 14.98 | 304 | 751 | 4.21 / 483.91 | 2 | 8 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 34 | 14.96 | 460 | 234 | 0.23 / 475.73 | 2 | 2 |
2 | 12 | 1141.96 | 2 | 15.05 | 1893 | 57 | 0.29 / 475.79 | 2 | 2 |
3 | 7 | 2005.92 | 31 | 14.59 | 2860 | 1294 | 1.58 / 477.08 | 2 | 3 |
4 | 13 | 1690.68 | 24 | 14.57 | 2498 | 874 | 2.46 / 477.95 | 2 | 3 |
5 | 13 | 964.60 | 24 | 14.69 | 1619 | 571 | 3.03 / 478.52 | 2 | 3 |
6 | 13 | 287.92 | 24 | 14.91 | 735 | 263 | 3.29 / 478.79 | 2 | 4 |
7 | 13 | 81.80 | 24 | 14.99 | 433 | 156 | 3.45 / 478.94 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.98 | 304 | 751 | 4.20 / 479.69 | 2 | 7 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 34 | 14.95 | 448 | 228 | 0.23 / 471.57 | 2 | 2 |
2 | 12 | 1151.88 | 2 | 15.06 | 1898 | 57 | 0.28 / 471.62 | 2 | 2 |
3 | 7 | 2004.76 | 31 | 14.60 | 2853 | 1291 | 1.58 / 472.92 | 2 | 3 |
4 | 13 | 1538.04 | 24 | 14.60 | 2325 | 815 | 2.39 / 473.73 | 2 | 3 |
5 | 13 | 1007.40 | 24 | 14.68 | 1676 | 590 | 2.98 / 474.32 | 2 | 4 |
6 | 13 | 293.20 | 24 | 14.91 | 742 | 266 | 3.25 / 474.59 | 2 | 4 |
7 | 13 | 84.44 | 24 | 14.99 | 437 | 157 | 3.40 / 474.74 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.98 | 304 | 751 | 4.16 / 475.50 | 2 | 6 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 34 | 14.96 | 437 | 222 | 0.22 / 467.38 | 2 | 2 |
2 | 12 | 1294.96 | 2 | 15.01 | 2109 | 63 | 0.29 / 467.45 | 2 | 2 |
3 | 7 | 2003.96 | 31 | 14.59 | 2866 | 1296 | 1.58 / 468.74 | 2 | 4 |
4 | 13 | 1548.20 | 24 | 14.59 | 2334 | 817 | 2.40 / 469.56 | 2 | 3 |
5 | 13 | 1022.80 | 24 | 14.67 | 1705 | 600 | 3.00 / 470.16 | 2 | 4 |
6 | 13 | 293.00 | 24 | 14.91 | 745 | 267 | 3.27 / 470.43 | 2 | 4 |
7 | 13 | 96.24 | 24 | 14.98 | 449 | 161 | 3.43 / 470.59 | 2 | 3 |
8 | 8 | 0.04 | 165 | 14.98 | 304 | 751 | 4.18 / 471.34 | 2 | 7 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 34 | 14.95 | 448 | 228 | 0.23 / 463.06 | 2 | 2 |
2 | 12 | 1281.96 | 2 | 15.01 | 2095 | 63 | 0.29 / 463.12 | 2 | 2 |
3 | 7 | 2006.44 | 31 | 14.60 | 2864 | 1296 | 1.59 / 464.42 | 2 | 3 |
4 | 13 | 1679.96 | 24 | 14.57 | 2490 | 871 | 2.46 / 465.29 | 2 | 3 |
5 | 13 | 997.16 | 24 | 14.69 | 1662 | 586 | 3.04 / 465.87 | 2 | 5 |
6 | 13 | 293.08 | 24 | 14.91 | 746 | 267 | 3.31 / 466.14 | 2 | 3 |
7 | 13 | 102.76 | 24 | 14.99 | 454 | 163 | 3.47 / 466.30 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.99 | 301 | 744 | 4.22 / 467.05 | 2 | 6 |
9 | 14 | 0.12 | 25 | 14.97 | 301 | 113 | 4.33 / 467.16 | 2 | 7 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.24 | 34 | 14.95 | 446 | 227 | 0.23 / 458.91 | 2 | 2 |
2 | 12 | 1132.16 | 2 | 15.06 | 1876 | 57 | 0.28 / 458.97 | 2 | 2 |
3 | 7 | 2006.96 | 31 | 14.59 | 2854 | 1291 | 1.57 / 460.26 | 2 | 3 |
4 | 13 | 1529.20 | 24 | 14.60 | 2309 | 809 | 2.38 / 461.07 | 2 | 3 |
5 | 13 | 1016.68 | 24 | 14.68 | 1683 | 593 | 2.98 / 461.66 | 2 | 4 |
6 | 13 | 285.04 | 24 | 14.91 | 732 | 262 | 3.24 / 461.92 | 2 | 4 |
7 | 13 | 83.24 | 24 | 14.99 | 434 | 156 | 3.39 / 462.08 | 2 | 3 |
8 | 8 | 0.28 | 165 | 14.99 | 303 | 749 | 4.14 / 462.83 | 2 | 5 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 34 | 14.95 | 454 | 231 | 0.23 / 454.73 | 2 | 2 |
2 | 12 | 1148.16 | 2 | 15.06 | 1921 | 58 | 0.29 / 454.79 | 2 | 2 |
3 | 7 | 2007.72 | 31 | 14.59 | 2864 | 1295 | 1.58 / 456.08 | 2 | 3 |
4 | 13 | 1532.08 | 24 | 14.61 | 2313 | 811 | 2.40 / 456.89 | 2 | 3 |
5 | 13 | 883.88 | 24 | 14.73 | 1511 | 534 | 2.93 / 457.43 | 2 | 4 |
6 | 13 | 242.48 | 24 | 14.94 | 662 | 237 | 3.17 / 457.67 | 2 | 3 |
7 | 13 | 80.36 | 24 | 15.00 | 420 | 151 | 3.32 / 457.82 | 2 | 2 |
8 | 13 | 47.56 | 24 | 15.00 | 368 | 132 | 3.45 / 457.95 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.98 | 298 | 737 | 4.19 / 458.69 | 2 | 9 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 34 | 14.95 | 446 | 227 | 0.23 / 450.26 | 2 | 2 |
2 | 12 | 1138.00 | 2 | 15.06 | 1902 | 57 | 0.28 / 450.32 | 2 | 2 |
3 | 7 | 2001.80 | 31 | 14.61 | 2854 | 1293 | 1.58 / 451.61 | 2 | 3 |
4 | 13 | 1687.48 | 24 | 14.58 | 2505 | 877 | 2.45 / 452.49 | 2 | 3 |
5 | 13 | 1144.48 | 24 | 14.65 | 1844 | 648 | 3.10 / 453.13 | 2 | 4 |
6 | 13 | 393.04 | 24 | 14.87 | 885 | 316 | 3.42 / 453.45 | 2 | 5 |
7 | 13 | 108.88 | 24 | 14.98 | 473 | 170 | 3.59 / 453.62 | 2 | 3 |
8 | 13 | 26.04 | 24 | 15.00 | 348 | 125 | 3.71 / 453.75 | 2 | 3 |
9 | 8 | 0.08 | 165 | 14.98 | 305 | 754 | 4.47 / 454.50 | 2 | 8 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 34 | 14.96 | 449 | 228 | 0.23 / 445.80 | 2 | 2 |
2 | 12 | 1155.92 | 2 | 15.07 | 1919 | 58 | 0.29 / 445.86 | 2 | 2 |
3 | 7 | 2003.76 | 31 | 14.61 | 2849 | 1290 | 1.58 / 447.15 | 2 | 4 |
4 | 13 | 1692.20 | 24 | 14.58 | 2504 | 876 | 2.45 / 448.02 | 2 | 3 |
5 | 13 | 1136.12 | 24 | 14.66 | 1827 | 643 | 3.10 / 448.67 | 2 | 4 |
6 | 13 | 387.36 | 24 | 14.88 | 876 | 313 | 3.41 / 448.98 | 2 | 4 |
7 | 13 | 106.76 | 24 | 14.98 | 472 | 170 | 3.58 / 449.15 | 2 | 3 |
8 | 13 | 27.12 | 24 | 15.00 | 354 | 127 | 3.71 / 449.28 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.98 | 306 | 756 | 4.46 / 450.03 | 2 | 9 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 34 | 14.96 | 445 | 226 | 0.23 / 441.60 | 2 | 2 |
2 | 12 | 1153.56 | 2 | 15.08 | 1906 | 57 | 0.28 / 441.66 | 2 | 2 |
3 | 7 | 2005.84 | 31 | 14.59 | 2860 | 1294 | 1.58 / 442.95 | 2 | 3 |
4 | 13 | 1679.88 | 24 | 14.58 | 2490 | 871 | 2.45 / 443.82 | 2 | 3 |
5 | 13 | 962.52 | 24 | 14.71 | 1615 | 570 | 3.02 / 444.39 | 2 | 4 |
6 | 13 | 280.36 | 24 | 14.93 | 727 | 260 | 3.28 / 444.65 | 2 | 4 |
7 | 13 | 89.04 | 24 | 15.00 | 445 | 160 | 3.44 / 444.81 | 2 | 3 |
8 | 8 | 0.20 | 165 | 14.99 | 306 | 757 | 4.20 / 445.57 | 2 | 6 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 34 | 14.95 | 448 | 228 | 0.23 / 437.43 | 2 | 2 |
2 | 12 | 1151.08 | 2 | 15.07 | 1904 | 57 | 0.29 / 437.48 | 2 | 2 |
3 | 7 | 2003.16 | 31 | 14.60 | 2856 | 1293 | 1.58 / 438.78 | 2 | 3 |
4 | 13 | 1531.16 | 24 | 14.61 | 2313 | 811 | 2.39 / 439.59 | 2 | 3 |
5 | 13 | 1019.44 | 24 | 14.68 | 1687 | 594 | 2.98 / 440.18 | 2 | 3 |
6 | 13 | 315.16 | 24 | 14.90 | 775 | 277 | 3.26 / 440.46 | 2 | 4 |
7 | 13 | 83.24 | 24 | 14.99 | 435 | 156 | 3.42 / 440.62 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.99 | 307 | 759 | 4.18 / 441.38 | 2 | 4 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 34 | 14.96 | 444 | 226 | 0.23 / 433.11 | 2 | 2 |
2 | 12 | 1162.16 | 2 | 15.05 | 1933 | 58 | 0.28 / 433.16 | 2 | 2 |
3 | 7 | 2008.28 | 31 | 14.61 | 2869 | 1299 | 1.58 / 434.46 | 2 | 3 |
4 | 13 | 1684.60 | 24 | 14.58 | 2492 | 872 | 2.46 / 435.34 | 2 | 4 |
5 | 13 | 979.84 | 24 | 14.71 | 1639 | 579 | 3.03 / 435.91 | 2 | 4 |
6 | 13 | 430.28 | 24 | 14.86 | 934 | 333 | 3.37 / 436.25 | 2 | 5 |
7 | 13 | 110.36 | 24 | 14.98 | 480 | 173 | 3.54 / 436.42 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.98 | 315 | 779 | 4.32 / 437.20 | 2 | 6 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 34 | 14.96 | 448 | 228 | 0.23 / 428.79 | 2 | 2 |
2 | 12 | 1149.28 | 2 | 15.07 | 1889 | 57 | 0.28 / 428.84 | 2 | 2 |
3 | 7 | 2004.08 | 31 | 14.61 | 2852 | 1292 | 1.58 / 430.13 | 2 | 3 |
4 | 13 | 1677.84 | 24 | 14.59 | 2482 | 869 | 2.45 / 431.00 | 2 | 3 |
5 | 13 | 985.64 | 24 | 14.70 | 1645 | 580 | 3.03 / 431.58 | 2 | 3 |
6 | 13 | 298.52 | 24 | 14.92 | 745 | 267 | 3.29 / 431.85 | 2 | 4 |
7 | 13 | 77.76 | 24 | 15.00 | 428 | 154 | 3.45 / 432.00 | 2 | 3 |
8 | 13 | 21.72 | 24 | 15.01 | 345 | 124 | 3.57 / 432.13 | 2 | 3 |
9 | 8 | 0.08 | 165 | 14.99 | 304 | 752 | 4.32 / 432.88 | 2 | 9 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 34 | 14.97 | 452 | 230 | 0.23 / 424.49 | 2 | 2 |
2 | 12 | 1148.56 | 2 | 15.07 | 1898 | 57 | 0.29 / 424.54 | 2 | 2 |
3 | 7 | 2008.76 | 31 | 14.60 | 2857 | 1293 | 1.58 / 425.84 | 2 | 3 |
4 | 13 | 1683.52 | 24 | 14.58 | 2488 | 871 | 2.45 / 426.71 | 2 | 3 |
5 | 13 | 973.88 | 24 | 14.71 | 1626 | 574 | 3.02 / 427.28 | 2 | 4 |
6 | 13 | 273.28 | 24 | 14.94 | 706 | 253 | 3.28 / 427.53 | 2 | 4 |
7 | 13 | 81.00 | 24 | 15.01 | 425 | 153 | 3.43 / 427.69 | 2 | 3 |
8 | 13 | 20.08 | 24 | 15.02 | 336 | 121 | 3.55 / 427.81 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.99 | 303 | 749 | 4.30 / 428.56 | 2 | 6 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 34 | 14.97 | 446 | 227 | 0.23 / 420.23 | 2 | 2 |
2 | 12 | 1150.24 | 2 | 15.06 | 1917 | 58 | 0.28 / 420.29 | 2 | 2 |
3 | 7 | 2002.96 | 32 | 14.60 | 2857 | 1335 | 1.62 / 421.62 | 2 | 3 |
4 | 13 | 1703.20 | 24 | 14.58 | 2518 | 881 | 2.50 / 422.50 | 2 | 3 |
5 | 13 | 986.08 | 24 | 14.70 | 1646 | 581 | 3.08 / 423.08 | 2 | 3 |
6 | 13 | 292.60 | 24 | 14.93 | 738 | 264 | 3.35 / 423.35 | 2 | 3 |
7 | 13 | 93.64 | 24 | 15.00 | 446 | 161 | 3.51 / 423.51 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.00 | 302 | 747 | 4.25 / 424.26 | 2 | 5 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 34 | 14.95 | 455 | 231 | 0.23 / 415.97 | 2 | 2 |
2 | 12 | 1167.08 | 2 | 15.06 | 1940 | 58 | 0.29 / 416.03 | 2 | 2 |
3 | 7 | 2009.20 | 31 | 14.61 | 2871 | 1300 | 1.59 / 417.33 | 2 | 3 |
4 | 13 | 1708.52 | 24 | 14.58 | 2523 | 883 | 2.47 / 418.21 | 2 | 3 |
5 | 13 | 1018.44 | 24 | 14.69 | 1684 | 594 | 3.07 / 418.81 | 2 | 4 |
6 | 13 | 330.04 | 24 | 14.91 | 790 | 283 | 3.35 / 419.09 | 2 | 4 |
7 | 13 | 89.08 | 24 | 15.00 | 443 | 159 | 3.51 / 419.25 | 2 | 3 |
8 | 8 | -0.08 | 165 | 15.00 | 305 | 755 | 4.26 / 420.00 | 2 | 7 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 34 | 14.96 | 447 | 227 | 0.23 / 411.77 | 2 | 2 |
2 | 12 | 1279.08 | 2 | 15.04 | 2077 | 62 | 0.29 / 411.83 | 2 | 2 |
3 | 7 | 1790.36 | 31 | 14.69 | 2610 | 1189 | 1.48 / 413.02 | 2 | 3 |
4 | 13 | 1651.12 | 24 | 14.64 | 2454 | 862 | 2.34 / 413.88 | 2 | 3 |
5 | 13 | 950.64 | 24 | 14.75 | 1601 | 567 | 2.91 / 414.45 | 2 | 3 |
6 | 13 | 246.84 | 24 | 14.95 | 678 | 243 | 3.15 / 414.69 | 2 | 3 |
7 | 13 | 76.56 | 24 | 15.01 | 425 | 153 | 3.30 / 414.85 | 2 | 3 |
8 | 13 | 20.08 | 24 | 15.02 | 343 | 124 | 3.43 / 414.97 | 2 | 3 |
9 | 8 | 0.08 | 165 | 14.98 | 311 | 769 | 4.20 / 415.74 | 2 | 6 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 34 | 14.95 | 451 | 229 | 0.23 / 407.68 | 2 | 2 |
2 | 12 | 1143.52 | 2 | 15.10 | 1901 | 57 | 0.29 / 407.74 | 2 | 2 |
3 | 7 | 1628.00 | 32 | 14.75 | 2415 | 1140 | 1.43 / 408.88 | 2 | 3 |
4 | 13 | 1504.84 | 24 | 14.70 | 2281 | 805 | 2.23 / 409.68 | 2 | 3 |
5 | 13 | 969.40 | 24 | 14.77 | 1621 | 575 | 2.81 / 410.25 | 2 | 4 |
6 | 13 | 249.80 | 24 | 14.97 | 685 | 246 | 3.05 / 410.50 | 2 | 3 |
7 | 13 | 63.68 | 24 | 15.02 | 415 | 150 | 3.20 / 410.65 | 2 | 3 |
8 | 13 | 17.32 | 24 | 15.03 | 341 | 123 | 3.32 / 410.77 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.99 | 311 | 769 | 4.09 / 411.54 | 2 | 9 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 34 | 14.95 | 448 | 228 | 0.23 / 403.37 | 2 | 2 |
2 | 12 | 1309.36 | 2 | 15.03 | 2123 | 64 | 0.29 / 403.44 | 2 | 2 |
3 | 7 | 1872.96 | 31 | 14.66 | 2706 | 1230 | 1.52 / 404.67 | 2 | 3 |
4 | 13 | 1571.92 | 24 | 14.65 | 2365 | 832 | 2.35 / 405.50 | 2 | 3 |
5 | 13 | 1049.28 | 24 | 14.71 | 1730 | 611 | 2.96 / 406.11 | 2 | 4 |
6 | 13 | 312.04 | 24 | 14.92 | 780 | 279 | 3.24 / 406.39 | 2 | 3 |
7 | 13 | 72.16 | 24 | 15.00 | 429 | 154 | 3.40 / 406.54 | 2 | 3 |
8 | 13 | 20.40 | 24 | 15.01 | 351 | 126 | 3.52 / 406.67 | 2 | 3 |
9 | 8 | 0.12 | 165 | 14.98 | 315 | 779 | 4.30 / 407.45 | 2 | 10 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 34 | 14.95 | 445 | 226 | 0.23 / 398.94 | 2 | 2 |
2 | 12 | 1307.44 | 2 | 15.06 | 2111 | 64 | 0.29 / 399.00 | 2 | 2 |
3 | 7 | 2004.24 | 31 | 14.63 | 2853 | 1294 | 1.58 / 400.30 | 2 | 3 |
4 | 13 | 1679.12 | 24 | 14.61 | 2495 | 875 | 2.46 / 401.17 | 2 | 3 |
5 | 13 | 963.36 | 24 | 14.73 | 1620 | 573 | 3.03 / 401.75 | 2 | 4 |
6 | 13 | 426.08 | 24 | 14.88 | 931 | 332 | 3.36 / 402.08 | 2 | 5 |
7 | 13 | 66.72 | 24 | 15.00 | 422 | 152 | 3.52 / 402.23 | 2 | 3 |
8 | 13 | 38.00 | 24 | 15.00 | 375 | 135 | 3.65 / 402.37 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.98 | 316 | 781 | 4.43 / 403.15 | 2 | 8 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 34 | 14.97 | 454 | 231 | 0.23 / 394.47 | 2 | 2 |
2 | 3 | 1021.56 | 1 | 15.12 | 1748 | 26 | 0.26 / 394.50 | 2 | 3 |
3 | 12 | 1307.00 | 2 | 15.05 | 2117 | 64 | 0.32 / 394.56 | 2 | 2 |
4 | 7 | 2005.84 | 31 | 14.63 | 2860 | 1297 | 1.62 / 395.86 | 2 | 4 |
5 | 13 | 1870.80 | 24 | 14.57 | 2714 | 949 | 2.57 / 396.81 | 2 | 3 |
6 | 13 | 971.72 | 24 | 14.72 | 1635 | 578 | 3.14 / 397.39 | 2 | 4 |
7 | 13 | 283.12 | 24 | 14.93 | 737 | 264 | 3.41 / 397.65 | 2 | 3 |
8 | 13 | 72.52 | 24 | 15.01 | 430 | 155 | 3.56 / 397.81 | 2 | 3 |
9 | 13 | 20.80 | 24 | 15.02 | 353 | 127 | 3.69 / 397.93 | 2 | 3 |
10 | 8 | 0.00 | 165 | 14.98 | 316 | 781 | 4.47 / 398.71 | 2 | 8 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 34 | 14.96 | 450 | 229 | 0.23 / 390.09 | 2 | 2 |
2 | 3 | 1022.44 | 1 | 15.11 | 1752 | 26 | 0.26 / 390.11 | 2 | 2 |
3 | 12 | 1136.44 | 2 | 15.10 | 1893 | 57 | 0.31 / 390.17 | 2 | 2 |
4 | 7 | 2013.56 | 31 | 14.63 | 2868 | 1301 | 1.61 / 391.47 | 2 | 3 |
5 | 13 | 1693.52 | 24 | 14.61 | 2502 | 877 | 2.49 / 392.35 | 2 | 3 |
6 | 13 | 1130.88 | 24 | 14.68 | 1829 | 644 | 3.13 / 392.99 | 2 | 3 |
7 | 13 | 374.08 | 24 | 14.90 | 864 | 309 | 3.44 / 393.30 | 2 | 6 |
8 | 13 | 86.72 | 24 | 15.00 | 451 | 162 | 3.61 / 393.46 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.00 | 315 | 780 | 4.39 / 394.24 | 2 | 9 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 34 | 14.99 | 449 | 229 | 0.23 / 385.74 | 2 | 2 |
2 | 12 | 1142.48 | 2 | 15.08 | 1920 | 58 | 0.29 / 385.80 | 2 | 2 |
3 | 7 | 2004.32 | 31 | 14.62 | 2868 | 1300 | 1.59 / 387.10 | 2 | 4 |
4 | 13 | 1560.92 | 24 | 14.62 | 2361 | 828 | 2.42 / 387.93 | 2 | 4 |
5 | 13 | 1040.32 | 24 | 14.69 | 1716 | 605 | 3.02 / 388.53 | 2 | 3 |
6 | 13 | 302.40 | 24 | 14.93 | 758 | 272 | 3.29 / 388.80 | 2 | 4 |
7 | 13 | 73.84 | 24 | 15.01 | 427 | 154 | 3.45 / 388.96 | 2 | 3 |
8 | 13 | 19.08 | 24 | 15.02 | 349 | 126 | 3.57 / 389.08 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.98 | 313 | 774 | 4.34 / 389.86 | 2 | 8 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 33 | 14.95 | 449 | 222 | 0.22 / 381.96 | 2 | 2 |
2 | 12 | 1301.00 | 2 | 15.05 | 2135 | 64 | 0.29 / 382.02 | 2 | 2 |
3 | 7 | 1518.04 | 31 | 14.80 | 2297 | 1054 | 1.34 / 383.08 | 2 | 3 |
4 | 13 | 1399.60 | 24 | 14.76 | 2161 | 766 | 2.11 / 383.84 | 2 | 3 |
5 | 13 | 881.08 | 24 | 14.82 | 1522 | 541 | 2.65 / 384.38 | 2 | 4 |
6 | 13 | 186.08 | 24 | 15.02 | 589 | 212 | 2.86 / 384.59 | 2 | 3 |
7 | 13 | 57.12 | 24 | 15.05 | 403 | 146 | 3.00 / 384.74 | 2 | 3 |
8 | 8 | 0.24 | 165 | 15.03 | 311 | 771 | 3.78 / 385.51 | 2 | 7 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 34 | 14.97 | 440 | 224 | 0.22 / 377.53 | 2 | 2 |
2 | 12 | 1148.20 | 2 | 15.09 | 1902 | 57 | 0.28 / 377.59 | 2 | 2 |
3 | 7 | 1951.60 | 32 | 14.63 | 2812 | 1316 | 1.60 / 378.90 | 2 | 3 |
4 | 13 | 1637.16 | 24 | 14.63 | 2440 | 857 | 2.45 / 379.76 | 2 | 3 |
5 | 13 | 1082.56 | 24 | 14.70 | 1767 | 623 | 3.08 / 380.38 | 2 | 4 |
6 | 13 | 327.88 | 24 | 14.92 | 801 | 287 | 3.36 / 380.67 | 2 | 4 |
7 | 13 | 73.52 | 24 | 15.01 | 432 | 156 | 3.52 / 380.83 | 2 | 3 |
8 | 13 | 20.16 | 24 | 15.02 | 353 | 127 | 3.65 / 380.95 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.99 | 316 | 782 | 4.43 / 381.74 | 2 | 10 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 34 | 14.96 | 451 | 229 | 0.23 / 373.31 | 2 | 2 |
2 | 12 | 1141.12 | 2 | 15.09 | 1886 | 57 | 0.29 / 373.37 | 2 | 2 |
3 | 7 | 1978.24 | 31 | 14.64 | 2824 | 1282 | 1.57 / 374.65 | 2 | 3 |
4 | 13 | 1667.40 | 24 | 14.62 | 2486 | 872 | 2.44 / 375.52 | 2 | 3 |
5 | 13 | 965.56 | 24 | 14.73 | 1627 | 575 | 3.02 / 376.10 | 2 | 4 |
6 | 13 | 295.64 | 24 | 14.94 | 753 | 270 | 3.29 / 376.37 | 2 | 5 |
7 | 13 | 76.96 | 24 | 15.01 | 437 | 157 | 3.44 / 376.52 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.00 | 316 | 782 | 4.22 / 377.31 | 2 | 7 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 33 | 14.98 | 448 | 221 | 0.22 / 368.96 | 2 | 2 |
2 | 12 | 1146.08 | 2 | 15.09 | 1923 | 58 | 0.28 / 369.02 | 2 | 2 |
3 | 7 | 2007.00 | 31 | 14.64 | 2867 | 1301 | 1.58 / 370.32 | 2 | 3 |
4 | 13 | 1693.12 | 24 | 14.62 | 2502 | 878 | 2.46 / 371.20 | 2 | 3 |
5 | 13 | 862.20 | 24 | 14.77 | 1491 | 529 | 2.99 / 371.73 | 2 | 5 |
6 | 13 | 326.96 | 24 | 14.92 | 797 | 285 | 3.27 / 372.02 | 2 | 5 |
7 | 13 | 73.32 | 24 | 15.01 | 432 | 156 | 3.43 / 372.17 | 2 | 3 |
8 | 13 | 20.60 | 24 | 15.02 | 352 | 127 | 3.55 / 372.30 | 2 | 3 |
9 | 8 | 0.04 | 165 | 14.99 | 317 | 784 | 4.34 / 373.08 | 2 | 10 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 33 | 14.97 | 437 | 216 | 0.22 / 364.68 | 2 | 2 |
2 | 12 | 1149.32 | 2 | 15.10 | 1916 | 58 | 0.27 / 364.74 | 2 | 2 |
3 | 7 | 2004.36 | 31 | 14.65 | 2865 | 1301 | 1.57 / 366.04 | 2 | 3 |
4 | 13 | 1546.84 | 24 | 14.65 | 2341 | 823 | 2.40 / 366.87 | 2 | 4 |
5 | 13 | 1045.20 | 24 | 14.72 | 1723 | 609 | 3.01 / 367.48 | 2 | 3 |
6 | 13 | 210.68 | 24 | 14.98 | 624 | 224 | 3.23 / 367.70 | 2 | 3 |
7 | 13 | 77.68 | 24 | 15.03 | 426 | 154 | 3.38 / 367.85 | 2 | 3 |
8 | 13 | 20.28 | 24 | 15.04 | 343 | 124 | 3.51 / 367.98 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.01 | 309 | 765 | 4.27 / 368.74 | 2 | 8 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 33 | 14.99 | 453 | 224 | 0.22 / 360.34 | 2 | 2 |
2 | 12 | 1162.88 | 2 | 15.11 | 1925 | 58 | 0.28 / 360.40 | 2 | 2 |
3 | 7 | 2005.84 | 31 | 14.64 | 2870 | 1303 | 1.58 / 361.70 | 2 | 3 |
4 | 13 | 1698.36 | 24 | 14.62 | 2510 | 881 | 2.47 / 362.58 | 2 | 3 |
5 | 13 | 981.04 | 24 | 14.73 | 1638 | 579 | 3.04 / 363.16 | 2 | 4 |
6 | 13 | 274.28 | 24 | 14.95 | 722 | 259 | 3.30 / 363.42 | 2 | 3 |
7 | 13 | 74.68 | 24 | 15.02 | 430 | 155 | 3.46 / 363.57 | 2 | 3 |
8 | 13 | 18.60 | 24 | 15.03 | 346 | 125 | 3.58 / 363.70 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.00 | 311 | 770 | 4.35 / 364.47 | 2 | 7 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 33 | 14.99 | 443 | 219 | 0.22 / 356.17 | 2 | 2 |
2 | 12 | 1162.28 | 2 | 15.10 | 1921 | 58 | 0.28 / 356.23 | 2 | 2 |
3 | 7 | 2004.88 | 31 | 14.64 | 2861 | 1298 | 1.58 / 357.53 | 2 | 3 |
4 | 13 | 1669.08 | 24 | 14.62 | 2482 | 871 | 2.45 / 358.40 | 2 | 4 |
5 | 13 | 920.72 | 24 | 14.76 | 1569 | 556 | 3.00 / 358.96 | 2 | 4 |
6 | 13 | 228.88 | 24 | 14.98 | 653 | 235 | 3.24 / 359.19 | 2 | 3 |
7 | 13 | 73.00 | 24 | 15.03 | 425 | 153 | 3.39 / 359.35 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.02 | 311 | 771 | 4.16 / 360.12 | 2 | 6 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 33 | 15.00 | 442 | 219 | 0.22 / 352.10 | 2 | 2 |
2 | 12 | 1161.40 | 2 | 15.11 | 1927 | 58 | 0.28 / 352.16 | 2 | 2 |
3 | 7 | 2012.20 | 31 | 14.64 | 2865 | 1300 | 1.58 / 353.46 | 2 | 3 |
4 | 13 | 1550.08 | 24 | 14.65 | 2331 | 820 | 2.40 / 354.28 | 2 | 3 |
5 | 13 | 886.52 | 24 | 14.76 | 1520 | 538 | 2.94 / 354.82 | 2 | 4 |
6 | 13 | 230.68 | 24 | 14.98 | 650 | 234 | 3.17 / 355.05 | 2 | 3 |
7 | 13 | 74.20 | 24 | 15.03 | 422 | 152 | 3.32 / 355.20 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.02 | 304 | 753 | 4.07 / 355.95 | 2 | 7 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 33 | 14.99 | 458 | 227 | 0.23 / 347.84 | 2 | 2 |
2 | 12 | 1158.52 | 2 | 15.11 | 1940 | 59 | 0.29 / 347.90 | 2 | 2 |
3 | 7 | 2010.92 | 32 | 14.65 | 2857 | 1339 | 1.62 / 349.24 | 2 | 3 |
4 | 13 | 1699.24 | 24 | 14.63 | 2502 | 879 | 2.50 / 350.12 | 2 | 3 |
5 | 13 | 988.44 | 24 | 14.74 | 1649 | 583 | 3.09 / 350.70 | 2 | 4 |
6 | 13 | 268.12 | 24 | 14.97 | 712 | 256 | 3.34 / 350.96 | 2 | 3 |
7 | 13 | 84.80 | 24 | 15.03 | 440 | 159 | 3.50 / 351.11 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.03 | 309 | 766 | 4.27 / 351.88 | 2 | 6 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 33 | 15.00 | 434 | 215 | 0.21 / 343.62 | 2 | 2 |
2 | 12 | 1162.60 | 2 | 15.11 | 1922 | 58 | 0.27 / 343.68 | 2 | 2 |
3 | 7 | 2003.84 | 31 | 14.65 | 2862 | 1300 | 1.57 / 344.98 | 2 | 3 |
4 | 13 | 1537.76 | 24 | 14.66 | 2325 | 818 | 2.39 / 345.80 | 2 | 4 |
5 | 13 | 884.36 | 24 | 14.77 | 1524 | 540 | 2.93 / 346.34 | 2 | 4 |
6 | 13 | 223.52 | 24 | 14.99 | 643 | 231 | 3.16 / 346.57 | 2 | 3 |
7 | 13 | 77.48 | 24 | 15.04 | 431 | 156 | 3.32 / 346.72 | 2 | 3 |
8 | 13 | 22.12 | 24 | 15.05 | 348 | 126 | 3.44 / 346.85 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.02 | 308 | 763 | 4.21 / 347.61 | 2 | 7 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 33 | 15.00 | 456 | 226 | 0.23 / 339.45 | 2 | 2 |
2 | 12 | 1145.92 | 2 | 15.11 | 1909 | 58 | 0.28 / 339.51 | 2 | 2 |
3 | 7 | 2003.80 | 31 | 14.64 | 2863 | 1299 | 1.58 / 340.81 | 2 | 4 |
4 | 13 | 1673.12 | 24 | 14.63 | 2488 | 874 | 2.46 / 341.68 | 2 | 4 |
5 | 13 | 957.32 | 24 | 14.76 | 1616 | 572 | 3.03 / 342.25 | 2 | 4 |
6 | 13 | 249.08 | 24 | 14.98 | 680 | 244 | 3.27 / 342.50 | 2 | 3 |
7 | 13 | 71.36 | 24 | 15.04 | 421 | 152 | 3.43 / 342.65 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.03 | 305 | 756 | 4.18 / 343.41 | 2 | 6 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 33 | 15.01 | 447 | 221 | 0.22 / 335.37 | 2 | 2 |
2 | 12 | 1164.00 | 2 | 15.11 | 1936 | 59 | 0.28 / 335.42 | 2 | 2 |
3 | 7 | 2001.68 | 31 | 14.66 | 2866 | 1302 | 1.58 / 336.73 | 2 | 3 |
4 | 13 | 1532.12 | 24 | 14.66 | 2315 | 815 | 2.40 / 337.54 | 2 | 3 |
5 | 13 | 874.36 | 24 | 14.78 | 1509 | 535 | 2.93 / 338.08 | 2 | 3 |
6 | 13 | 209.24 | 24 | 15.01 | 622 | 224 | 3.16 / 338.30 | 2 | 3 |
7 | 13 | 70.28 | 24 | 15.05 | 419 | 151 | 3.31 / 338.45 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.04 | 311 | 772 | 4.08 / 339.22 | 2 | 5 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 33 | 15.01 | 458 | 227 | 0.23 / 331.29 | 2 | 2 |
2 | 12 | 1148.32 | 2 | 15.12 | 1901 | 57 | 0.28 / 331.35 | 2 | 2 |
3 | 7 | 2004.76 | 31 | 14.65 | 2858 | 1298 | 1.58 / 332.65 | 2 | 2 |
4 | 13 | 1550.00 | 24 | 14.66 | 2339 | 823 | 2.41 / 333.47 | 2 | 3 |
5 | 13 | 886.20 | 24 | 14.78 | 1525 | 541 | 2.95 / 334.01 | 2 | 4 |
6 | 13 | 210.72 | 24 | 15.01 | 619 | 223 | 3.17 / 334.23 | 2 | 3 |
7 | 13 | 74.88 | 24 | 15.05 | 420 | 152 | 3.32 / 334.39 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.05 | 306 | 760 | 4.08 / 335.14 | 2 | 7 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 33 | 15.02 | 450 | 223 | 0.22 / 327.08 | 2 | 2 |
2 | 12 | 1157.04 | 2 | 15.12 | 1937 | 59 | 0.28 / 327.13 | 2 | 2 |
3 | 7 | 2005.36 | 31 | 14.65 | 2861 | 1299 | 1.58 / 328.43 | 2 | 3 |
4 | 13 | 1672.16 | 24 | 14.64 | 2478 | 871 | 2.45 / 329.30 | 2 | 3 |
5 | 13 | 957.44 | 24 | 14.77 | 1614 | 572 | 3.02 / 329.88 | 2 | 4 |
6 | 13 | 268.16 | 24 | 14.99 | 712 | 256 | 3.28 / 330.13 | 2 | 3 |
7 | 13 | 74.44 | 24 | 15.05 | 427 | 154 | 3.43 / 330.29 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.04 | 313 | 777 | 4.21 / 331.06 | 2 | 8 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 33 | 15.02 | 447 | 222 | 0.22 / 322.91 | 2 | 2 |
2 | 12 | 1166.60 | 2 | 15.11 | 1945 | 59 | 0.28 / 322.97 | 2 | 2 |
3 | 7 | 2005.64 | 31 | 14.65 | 2857 | 1298 | 1.58 / 324.26 | 2 | 3 |
4 | 13 | 1533.28 | 24 | 14.67 | 2309 | 813 | 2.39 / 325.08 | 2 | 3 |
5 | 13 | 1018.72 | 24 | 14.75 | 1683 | 596 | 2.99 / 325.67 | 2 | 4 |
6 | 13 | 288.92 | 24 | 14.98 | 727 | 261 | 3.25 / 325.93 | 2 | 3 |
7 | 13 | 86.96 | 24 | 15.05 | 437 | 158 | 3.41 / 326.09 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.05 | 307 | 762 | 4.17 / 326.85 | 2 | 6 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 33 | 15.02 | 448 | 222 | 0.22 / 318.71 | 2 | 2 |
2 | 12 | 1153.84 | 2 | 15.13 | 1922 | 58 | 0.28 / 318.77 | 2 | 2 |
3 | 7 | 2006.76 | 31 | 14.66 | 2860 | 1300 | 1.58 / 320.07 | 2 | 3 |
4 | 13 | 1670.64 | 24 | 14.65 | 2475 | 870 | 2.45 / 320.94 | 2 | 3 |
5 | 13 | 965.52 | 24 | 14.77 | 1625 | 576 | 3.03 / 321.52 | 2 | 4 |
6 | 13 | 259.28 | 24 | 15.00 | 688 | 248 | 3.27 / 321.76 | 2 | 3 |
7 | 13 | 97.48 | 24 | 15.06 | 445 | 161 | 3.43 / 321.93 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.05 | 306 | 760 | 4.19 / 322.69 | 2 | 7 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 33 | 15.03 | 443 | 220 | 0.22 / 314.46 | 2 | 2 |
2 | 12 | 1143.84 | 2 | 15.13 | 1915 | 58 | 0.28 / 314.52 | 2 | 2 |
3 | 7 | 2002.16 | 31 | 14.67 | 2859 | 1300 | 1.58 / 315.82 | 2 | 4 |
4 | 13 | 1697.00 | 24 | 14.64 | 2512 | 883 | 2.46 / 316.70 | 2 | 5 |
5 | 13 | 1006.56 | 24 | 14.76 | 1672 | 592 | 3.05 / 317.29 | 2 | 4 |
6 | 13 | 287.16 | 24 | 14.99 | 738 | 266 | 3.32 / 317.56 | 2 | 3 |
7 | 13 | 73.68 | 24 | 15.06 | 423 | 153 | 3.47 / 317.71 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.05 | 313 | 777 | 4.25 / 318.49 | 2 | 5 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 33 | 15.02 | 446 | 221 | 0.22 / 310.24 | 2 | 2 |
2 | 12 | 1160.96 | 2 | 15.12 | 1921 | 58 | 0.28 / 310.30 | 2 | 2 |
3 | 7 | 2004.04 | 31 | 14.68 | 2862 | 1302 | 1.58 / 311.60 | 2 | 2 |
4 | 13 | 1696.56 | 24 | 14.65 | 2503 | 880 | 2.46 / 312.48 | 2 | 3 |
5 | 13 | 968.72 | 24 | 14.78 | 1624 | 576 | 3.04 / 313.06 | 2 | 3 |
6 | 13 | 272.92 | 24 | 15.00 | 721 | 260 | 3.30 / 313.31 | 2 | 3 |
7 | 13 | 83.12 | 24 | 15.06 | 441 | 159 | 3.46 / 313.47 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.06 | 309 | 768 | 4.22 / 314.24 | 2 | 9 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 33 | 15.03 | 446 | 221 | 0.22 / 305.90 | 2 | 2 |
2 | 12 | 1141.60 | 2 | 15.12 | 1914 | 58 | 0.28 / 305.96 | 2 | 2 |
3 | 7 | 2009.92 | 31 | 14.67 | 2868 | 1304 | 1.58 / 307.26 | 2 | 3 |
4 | 13 | 1542.64 | 24 | 14.68 | 2330 | 821 | 2.40 / 308.08 | 2 | 3 |
5 | 13 | 1027.48 | 24 | 14.76 | 1696 | 601 | 3.01 / 308.68 | 2 | 4 |
6 | 13 | 312.96 | 24 | 14.98 | 767 | 276 | 3.28 / 308.96 | 2 | 4 |
7 | 13 | 89.12 | 24 | 15.06 | 445 | 161 | 3.44 / 309.12 | 2 | 3 |
8 | 13 | 22.28 | 24 | 15.08 | 351 | 127 | 3.57 / 309.25 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.05 | 310 | 770 | 4.34 / 310.02 | 2 | 9 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 33 | 15.04 | 442 | 219 | 0.22 / 301.55 | 2 | 2 |
2 | 12 | 1145.80 | 2 | 15.13 | 1913 | 58 | 0.28 / 301.61 | 2 | 2 |
3 | 7 | 2007.80 | 31 | 14.68 | 2866 | 1304 | 1.58 / 302.92 | 2 | 3 |
4 | 13 | 1691.52 | 24 | 14.66 | 2501 | 880 | 2.46 / 303.79 | 2 | 3 |
5 | 13 | 971.64 | 24 | 14.78 | 1638 | 581 | 3.04 / 304.38 | 2 | 5 |
6 | 13 | 272.68 | 24 | 15.01 | 718 | 259 | 3.30 / 304.63 | 2 | 4 |
7 | 13 | 79.20 | 24 | 15.08 | 431 | 156 | 3.46 / 304.79 | 2 | 3 |
8 | 13 | 20.04 | 24 | 15.09 | 340 | 123 | 3.58 / 304.91 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.06 | 308 | 765 | 4.35 / 305.68 | 2 | 8 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 33 | 15.04 | 454 | 225 | 0.23 / 297.34 | 2 | 2 |
2 | 12 | 1290.72 | 2 | 15.09 | 2108 | 64 | 0.29 / 297.41 | 2 | 2 |
3 | 7 | 2002.52 | 31 | 14.67 | 2850 | 1296 | 1.59 / 298.70 | 2 | 2 |
4 | 13 | 1690.96 | 24 | 14.65 | 2501 | 879 | 2.46 / 299.58 | 2 | 3 |
5 | 13 | 955.32 | 24 | 14.79 | 1611 | 572 | 3.04 / 300.16 | 2 | 4 |
6 | 13 | 263.72 | 24 | 15.02 | 696 | 251 | 3.29 / 300.41 | 2 | 3 |
7 | 13 | 71.84 | 24 | 15.08 | 417 | 151 | 3.44 / 300.56 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.07 | 312 | 776 | 4.21 / 301.33 | 2 | 6 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 33 | 15.04 | 455 | 226 | 0.23 / 293.11 | 2 | 2 |
2 | 12 | 1290.52 | 2 | 15.10 | 2097 | 63 | 0.29 / 293.17 | 2 | 2 |
3 | 7 | 2003.36 | 31 | 14.68 | 2864 | 1303 | 1.59 / 294.48 | 2 | 3 |
4 | 13 | 1682.64 | 24 | 14.66 | 2495 | 878 | 2.47 / 295.35 | 2 | 3 |
5 | 13 | 971.08 | 24 | 14.79 | 1631 | 579 | 3.05 / 295.93 | 2 | 4 |
6 | 13 | 285.96 | 24 | 15.02 | 730 | 263 | 3.31 / 296.20 | 2 | 3 |
7 | 13 | 102.16 | 24 | 15.08 | 455 | 165 | 3.48 / 296.36 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.08 | 305 | 759 | 4.24 / 297.12 | 2 | 7 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 33 | 15.05 | 441 | 219 | 0.22 / 288.94 | 2 | 2 |
2 | 12 | 1145.76 | 2 | 15.15 | 1915 | 58 | 0.28 / 288.99 | 2 | 2 |
3 | 7 | 2007.48 | 31 | 14.67 | 2852 | 1297 | 1.57 / 290.29 | 2 | 3 |
4 | 13 | 1682.44 | 24 | 14.66 | 2487 | 875 | 2.45 / 291.17 | 2 | 3 |
5 | 13 | 835.96 | 24 | 14.83 | 1462 | 520 | 2.97 / 291.69 | 2 | 6 |
6 | 13 | 300.56 | 24 | 15.01 | 753 | 271 | 3.24 / 291.96 | 2 | 3 |
7 | 13 | 71.92 | 24 | 15.09 | 424 | 154 | 3.39 / 292.11 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.07 | 311 | 773 | 4.17 / 292.88 | 2 | 7 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 33 | 15.05 | 445 | 221 | 0.22 / 284.63 | 2 | 2 |
2 | 12 | 1158.68 | 2 | 15.15 | 1918 | 58 | 0.28 / 284.69 | 2 | 2 |
3 | 7 | 2002.04 | 31 | 14.67 | 2860 | 1301 | 1.58 / 285.99 | 2 | 3 |
4 | 13 | 1683.88 | 24 | 14.66 | 2477 | 872 | 2.45 / 286.86 | 2 | 3 |
5 | 13 | 971.16 | 24 | 14.80 | 1620 | 575 | 3.03 / 287.44 | 2 | 3 |
6 | 13 | 282.08 | 24 | 15.02 | 717 | 258 | 3.29 / 287.70 | 2 | 3 |
7 | 13 | 63.92 | 24 | 15.10 | 402 | 146 | 3.43 / 287.84 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.08 | 305 | 759 | 4.19 / 288.60 | 2 | 7 |
9 | 14 | 0.12 | 25 | 15.06 | 305 | 115 | 4.30 / 288.72 | 3 | 10 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 33 | 15.06 | 434 | 216 | 0.22 / 280.41 | 2 | 2 |
2 | 12 | 1308.12 | 2 | 15.09 | 2123 | 64 | 0.28 / 280.47 | 2 | 3 |
3 | 7 | 2005.12 | 31 | 14.69 | 2859 | 1302 | 1.58 / 281.77 | 3 | 3 |
4 | 13 | 1662.84 | 24 | 14.67 | 2463 | 867 | 2.45 / 282.64 | 2 | 3 |
5 | 13 | 976.24 | 24 | 14.80 | 1638 | 582 | 3.03 / 283.22 | 2 | 4 |
6 | 13 | 277.84 | 24 | 15.02 | 729 | 263 | 3.29 / 283.48 | 2 | 3 |
7 | 13 | 68.92 | 24 | 15.09 | 420 | 152 | 3.45 / 283.64 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.08 | 312 | 776 | 4.22 / 284.41 | 2 | 7 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 33 | 15.05 | 447 | 222 | 0.22 / 276.09 | 2 | 2 |
2 | 12 | 1141.48 | 2 | 15.15 | 1892 | 57 | 0.28 / 276.15 | 2 | 2 |
3 | 7 | 2003.00 | 31 | 14.68 | 2871 | 1307 | 1.59 / 277.46 | 2 | 3 |
4 | 13 | 1683.60 | 24 | 14.67 | 2492 | 877 | 2.46 / 278.33 | 2 | 3 |
5 | 13 | 956.76 | 24 | 14.81 | 1614 | 574 | 3.04 / 278.91 | 2 | 3 |
6 | 13 | 241.44 | 24 | 15.04 | 668 | 241 | 3.28 / 279.15 | 2 | 3 |
7 | 13 | 68.44 | 24 | 15.10 | 420 | 152 | 3.43 / 279.30 | 2 | 3 |
8 | 13 | 24.48 | 24 | 15.11 | 346 | 125 | 3.56 / 279.43 | 2 | 3 |
9 | 8 | -0.04 | 165 | 15.08 | 307 | 764 | 4.32 / 280.19 | 2 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 33 | 15.07 | 442 | 220 | 0.22 / 271.78 | 2 | 2 |
2 | 12 | 1146.44 | 2 | 15.14 | 1921 | 58 | 0.28 / 271.83 | 2 | 2 |
3 | 7 | 2006.60 | 31 | 14.68 | 2860 | 1302 | 1.58 / 273.14 | 2 | 3 |
4 | 13 | 1527.04 | 24 | 14.70 | 2314 | 816 | 2.40 / 273.95 | 2 | 3 |
5 | 13 | 1019.16 | 24 | 14.78 | 1692 | 600 | 3.00 / 274.55 | 2 | 4 |
6 | 13 | 271.00 | 24 | 15.03 | 717 | 259 | 3.25 / 274.81 | 2 | 4 |
7 | 13 | 63.56 | 24 | 15.10 | 421 | 153 | 3.41 / 274.96 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.08 | 317 | 789 | 4.20 / 275.75 | 2 | 7 |
9 | 14 | -0.04 | 25 | 15.06 | 313 | 118 | 4.31 / 275.87 | 2 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 33 | 15.06 | 443 | 220 | 0.22 / 267.59 | 2 | 2 |
2 | 12 | 1162.04 | 2 | 15.15 | 1929 | 58 | 0.28 / 267.65 | 2 | 2 |
3 | 7 | 2003.28 | 31 | 14.69 | 2852 | 1299 | 1.58 / 268.95 | 2 | 3 |
4 | 13 | 1530.68 | 24 | 14.70 | 2316 | 817 | 2.39 / 269.76 | 2 | 3 |
5 | 13 | 1008.80 | 24 | 14.80 | 1684 | 598 | 2.99 / 270.36 | 2 | 4 |
6 | 13 | 284.20 | 24 | 15.03 | 734 | 265 | 3.26 / 270.63 | 2 | 3 |
7 | 13 | 69.40 | 24 | 15.11 | 422 | 153 | 3.41 / 270.78 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.10 | 312 | 777 | 4.19 / 271.56 | 2 | 7 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 33 | 15.06 | 446 | 222 | 0.22 / 263.36 | 2 | 2 |
2 | 12 | 1158.12 | 2 | 15.15 | 1920 | 58 | 0.28 / 263.42 | 2 | 2 |
3 | 7 | 2004.20 | 31 | 14.68 | 2863 | 1303 | 1.58 / 264.73 | 2 | 2 |
4 | 13 | 1703.04 | 24 | 14.67 | 2509 | 883 | 2.47 / 265.61 | 2 | 3 |
5 | 13 | 974.64 | 24 | 14.81 | 1635 | 581 | 3.05 / 266.19 | 2 | 4 |
6 | 13 | 261.36 | 24 | 15.05 | 700 | 253 | 3.30 / 266.44 | 2 | 3 |
7 | 13 | 58.44 | 24 | 15.11 | 408 | 148 | 3.45 / 266.59 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.10 | 312 | 777 | 4.23 / 267.37 | 2 | 9 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 33 | 15.06 | 447 | 222 | 0.22 / 259.16 | 2 | 2 |
2 | 12 | 1136.32 | 2 | 15.14 | 1900 | 58 | 0.28 / 259.21 | 2 | 2 |
3 | 7 | 2002.80 | 31 | 14.70 | 2865 | 1306 | 1.59 / 260.52 | 2 | 3 |
4 | 13 | 1533.56 | 24 | 14.71 | 2327 | 822 | 2.41 / 261.34 | 2 | 4 |
5 | 13 | 880.24 | 24 | 14.84 | 1530 | 545 | 2.95 / 261.89 | 2 | 3 |
6 | 13 | 351.48 | 24 | 15.00 | 836 | 301 | 3.25 / 262.19 | 2 | 4 |
7 | 13 | 72.24 | 24 | 15.10 | 435 | 158 | 3.41 / 262.34 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.09 | 321 | 799 | 4.21 / 263.14 | 2 | 13 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 33 | 15.07 | 447 | 222 | 0.22 / 254.93 | 2 | 2 |
2 | 12 | 1169.48 | 2 | 15.14 | 1952 | 59 | 0.28 / 254.99 | 2 | 2 |
3 | 7 | 2005.36 | 31 | 14.69 | 2869 | 1307 | 1.59 / 256.29 | 2 | 3 |
4 | 13 | 1544.28 | 24 | 14.70 | 2331 | 822 | 2.41 / 257.11 | 2 | 4 |
5 | 13 | 929.00 | 24 | 14.83 | 1571 | 559 | 2.97 / 257.67 | 2 | 3 |
6 | 13 | 374.28 | 24 | 15.00 | 861 | 310 | 3.28 / 257.98 | 2 | 4 |
7 | 13 | 81.60 | 24 | 15.10 | 444 | 161 | 3.44 / 258.14 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.09 | 317 | 789 | 4.23 / 258.93 | 2 | 8 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 33 | 15.08 | 444 | 221 | 0.22 / 250.70 | 2 | 2 |
2 | 12 | 1142.16 | 2 | 15.15 | 1908 | 58 | 0.28 / 250.76 | 2 | 2 |
3 | 7 | 2004.88 | 31 | 14.70 | 2861 | 1304 | 1.58 / 252.06 | 2 | 3 |
4 | 13 | 1689.20 | 24 | 14.68 | 2494 | 879 | 2.46 / 252.94 | 2 | 3 |
5 | 13 | 962.28 | 24 | 14.83 | 1616 | 575 | 3.04 / 253.51 | 2 | 4 |
6 | 13 | 256.36 | 24 | 15.06 | 696 | 252 | 3.29 / 253.76 | 2 | 3 |
7 | 13 | 58.40 | 24 | 15.12 | 412 | 150 | 3.44 / 253.91 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.10 | 317 | 790 | 4.23 / 254.70 | 2 | 12 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 33 | 15.08 | 447 | 222 | 0.22 / 246.51 | 2 | 2 |
2 | 12 | 1170.28 | 2 | 15.15 | 1947 | 59 | 0.28 / 246.57 | 2 | 2 |
3 | 7 | 2007.00 | 31 | 14.69 | 2870 | 1307 | 1.59 / 247.88 | 2 | 3 |
4 | 13 | 1531.96 | 24 | 14.72 | 2320 | 820 | 2.41 / 248.70 | 2 | 4 |
5 | 13 | 996.44 | 24 | 14.81 | 1661 | 590 | 3.00 / 249.29 | 2 | 4 |
6 | 13 | 257.76 | 24 | 15.06 | 699 | 253 | 3.25 / 249.54 | 2 | 3 |
7 | 13 | 55.80 | 24 | 15.12 | 408 | 148 | 3.40 / 249.69 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.10 | 317 | 790 | 4.19 / 250.48 | 2 | 7 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 33 | 15.09 | 455 | 227 | 0.23 / 242.17 | 2 | 2 |
2 | 12 | 1153.56 | 2 | 15.15 | 1927 | 58 | 0.28 / 242.23 | 2 | 2 |
3 | 7 | 2003.56 | 31 | 14.70 | 2861 | 1304 | 1.59 / 243.53 | 2 | 3 |
4 | 13 | 1685.04 | 24 | 14.69 | 2494 | 879 | 2.47 / 244.41 | 2 | 3 |
5 | 13 | 954.48 | 24 | 14.84 | 1615 | 575 | 3.04 / 244.99 | 2 | 3 |
6 | 13 | 245.16 | 24 | 15.07 | 677 | 245 | 3.29 / 245.23 | 2 | 3 |
7 | 13 | 68.56 | 24 | 15.13 | 419 | 152 | 3.44 / 245.38 | 2 | 3 |
8 | 13 | 18.92 | 24 | 15.14 | 345 | 125 | 3.57 / 245.51 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.10 | 312 | 777 | 4.34 / 246.29 | 2 | 9 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 33 | 15.08 | 452 | 225 | 0.22 / 237.84 | 2 | 2 |
2 | 12 | 1155.00 | 2 | 15.16 | 1911 | 58 | 0.28 / 237.90 | 2 | 2 |
3 | 7 | 2004.20 | 31 | 14.71 | 2858 | 1303 | 1.59 / 239.20 | 2 | 4 |
4 | 13 | 1707.64 | 24 | 14.68 | 2525 | 890 | 2.48 / 240.09 | 2 | 3 |
5 | 13 | 1167.04 | 24 | 14.77 | 1876 | 665 | 3.14 / 240.75 | 2 | 3 |
6 | 13 | 252.64 | 24 | 15.07 | 690 | 250 | 3.39 / 241.00 | 2 | 3 |
7 | 13 | 59.76 | 24 | 15.13 | 414 | 150 | 3.54 / 241.15 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.12 | 317 | 791 | 4.33 / 241.94 | 2 | 8 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 33 | 15.08 | 445 | 221 | 0.22 / 233.49 | 2 | 2 |
2 | 12 | 1165.24 | 2 | 15.17 | 1927 | 58 | 0.28 / 233.55 | 2 | 2 |
3 | 7 | 2003.60 | 31 | 14.71 | 2863 | 1306 | 1.59 / 234.85 | 2 | 4 |
4 | 13 | 1672.40 | 24 | 14.70 | 2479 | 875 | 2.46 / 235.73 | 2 | 3 |
5 | 13 | 959.24 | 24 | 14.84 | 1616 | 576 | 3.04 / 236.30 | 2 | 6 |
6 | 13 | 255.28 | 24 | 15.07 | 691 | 250 | 3.29 / 236.55 | 2 | 3 |
7 | 13 | 60.44 | 24 | 15.14 | 415 | 151 | 3.44 / 236.70 | 2 | 3 |
8 | 13 | 18.36 | 24 | 15.14 | 346 | 126 | 3.56 / 236.83 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.11 | 315 | 785 | 4.35 / 237.61 | 2 | 7 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 33 | 15.09 | 450 | 224 | 0.22 / 229.29 | 2 | 2 |
2 | 12 | 1150.20 | 2 | 15.16 | 1915 | 58 | 0.28 / 229.35 | 2 | 3 |
3 | 7 | 2007.04 | 31 | 14.71 | 2864 | 1306 | 1.59 / 230.65 | 3 | 2 |
4 | 13 | 1534.32 | 24 | 14.72 | 2325 | 821 | 2.41 / 231.47 | 2 | 4 |
5 | 13 | 998.72 | 24 | 14.83 | 1668 | 594 | 3.00 / 232.07 | 2 | 4 |
6 | 13 | 261.00 | 24 | 15.07 | 704 | 255 | 3.26 / 232.32 | 2 | 3 |
7 | 13 | 55.36 | 24 | 15.13 | 408 | 148 | 3.41 / 232.47 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.12 | 319 | 796 | 4.20 / 233.27 | 2 | 8 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 33 | 15.10 | 452 | 225 | 0.23 / 225.05 | 2 | 2 |
2 | 12 | 1303.40 | 2 | 15.12 | 2121 | 64 | 0.29 / 225.11 | 2 | 2 |
3 | 7 | 2004.44 | 31 | 14.71 | 2852 | 1301 | 1.59 / 226.41 | 2 | 2 |
4 | 13 | 1667.04 | 24 | 14.70 | 2480 | 875 | 2.46 / 227.29 | 2 | 3 |
5 | 13 | 974.96 | 24 | 14.84 | 1639 | 584 | 3.05 / 227.87 | 2 | 3 |
6 | 13 | 261.64 | 24 | 15.07 | 704 | 255 | 3.30 / 228.12 | 2 | 3 |
7 | 13 | 69.24 | 24 | 15.14 | 425 | 154 | 3.46 / 228.28 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.12 | 315 | 786 | 4.24 / 229.06 | 2 | 8 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 33 | 15.09 | 451 | 225 | 0.22 / 220.93 | 2 | 2 |
2 | 12 | 1154.28 | 2 | 15.17 | 1916 | 58 | 0.28 / 220.99 | 2 | 2 |
3 | 7 | 2006.76 | 31 | 14.70 | 2865 | 1306 | 1.59 / 222.30 | 2 | 3 |
4 | 13 | 1542.40 | 24 | 14.72 | 2325 | 821 | 2.41 / 223.12 | 2 | 3 |
5 | 13 | 869.64 | 24 | 14.87 | 1506 | 537 | 2.95 / 223.65 | 2 | 4 |
6 | 13 | 211.56 | 24 | 15.10 | 626 | 227 | 3.17 / 223.88 | 2 | 3 |
7 | 13 | 58.92 | 24 | 15.15 | 412 | 150 | 3.32 / 224.03 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.13 | 316 | 789 | 4.11 / 224.82 | 2 | 6 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 33 | 15.10 | 450 | 224 | 0.22 / 216.70 | 2 | 2 |
2 | 12 | 1146.36 | 2 | 15.18 | 1922 | 58 | 0.28 / 216.76 | 2 | 2 |
3 | 7 | 2004.24 | 31 | 14.71 | 2858 | 1303 | 1.59 / 218.06 | 2 | 3 |
4 | 13 | 1689.76 | 24 | 14.70 | 2514 | 887 | 2.47 / 218.95 | 2 | 3 |
5 | 13 | 836.68 | 24 | 14.90 | 1465 | 524 | 3.00 / 219.47 | 2 | 4 |
6 | 13 | 304.28 | 24 | 15.06 | 768 | 278 | 3.27 / 219.75 | 2 | 3 |
7 | 13 | 66.72 | 24 | 15.14 | 427 | 155 | 3.43 / 219.90 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.13 | 322 | 804 | 4.23 / 220.71 | 2 | 7 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 33 | 15.11 | 451 | 225 | 0.22 / 212.48 | 2 | 2 |
2 | 12 | 1329.40 | 2 | 15.13 | 2135 | 65 | 0.29 / 212.54 | 2 | 2 |
3 | 7 | 2003.64 | 31 | 14.71 | 2866 | 1307 | 1.60 / 213.85 | 2 | 3 |
4 | 13 | 1537.96 | 24 | 14.73 | 2335 | 825 | 2.42 / 214.67 | 2 | 3 |
5 | 13 | 1004.04 | 24 | 14.83 | 1670 | 594 | 3.02 / 215.27 | 2 | 4 |
6 | 13 | 286.56 | 24 | 15.07 | 736 | 266 | 3.28 / 215.53 | 2 | 4 |
7 | 13 | 68.40 | 24 | 15.14 | 425 | 154 | 3.44 / 215.69 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.13 | 315 | 786 | 4.22 / 216.47 | 2 | 6 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 33 | 15.10 | 449 | 224 | 0.22 / 208.21 | 2 | 2 |
2 | 12 | 1150.72 | 2 | 15.18 | 1920 | 58 | 0.28 / 208.27 | 2 | 2 |
3 | 7 | 2006.04 | 31 | 14.72 | 2860 | 1305 | 1.59 / 209.57 | 2 | 3 |
4 | 13 | 1698.52 | 24 | 14.70 | 2528 | 892 | 2.48 / 210.47 | 2 | 3 |
5 | 13 | 982.92 | 24 | 14.84 | 1655 | 589 | 3.07 / 211.06 | 2 | 3 |
6 | 13 | 275.32 | 24 | 15.08 | 722 | 261 | 3.33 / 211.32 | 2 | 4 |
7 | 13 | 76.64 | 24 | 15.15 | 438 | 159 | 3.49 / 211.48 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.14 | 310 | 774 | 4.26 / 212.25 | 2 | 6 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 33 | 15.11 | 453 | 226 | 0.23 / 203.84 | 2 | 2 |
2 | 12 | 1151.48 | 2 | 15.18 | 1911 | 58 | 0.28 / 203.89 | 2 | 2 |
3 | 7 | 2004.32 | 31 | 14.72 | 2857 | 1304 | 1.59 / 205.20 | 2 | 4 |
4 | 13 | 1684.76 | 24 | 14.71 | 2496 | 881 | 2.47 / 206.08 | 2 | 3 |
5 | 13 | 973.76 | 24 | 14.85 | 1638 | 584 | 3.05 / 206.66 | 2 | 4 |
6 | 13 | 267.40 | 24 | 15.09 | 712 | 258 | 3.31 / 206.92 | 2 | 3 |
7 | 13 | 67.64 | 24 | 15.15 | 423 | 154 | 3.46 / 207.07 | 2 | 3 |
8 | 13 | 16.88 | 24 | 15.16 | 348 | 127 | 3.59 / 207.20 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.13 | 315 | 786 | 4.38 / 207.99 | 2 | 7 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 33 | 15.11 | 442 | 220 | 0.22 / 199.76 | 2 | 2 |
2 | 12 | 1149.60 | 2 | 15.18 | 1933 | 59 | 0.28 / 199.82 | 2 | 2 |
3 | 7 | 2003.20 | 31 | 14.71 | 2864 | 1306 | 1.59 / 201.12 | 2 | 4 |
4 | 13 | 1524.76 | 24 | 14.74 | 2312 | 818 | 2.40 / 201.94 | 2 | 4 |
5 | 13 | 854.64 | 24 | 14.89 | 1486 | 531 | 2.93 / 202.47 | 2 | 4 |
6 | 13 | 191.28 | 24 | 15.13 | 597 | 217 | 3.15 / 202.69 | 2 | 3 |
7 | 13 | 61.20 | 24 | 15.17 | 402 | 146 | 3.30 / 202.83 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.15 | 311 | 777 | 4.07 / 203.61 | 2 | 5 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 33 | 15.11 | 455 | 227 | 0.23 / 195.52 | 2 | 2 |
2 | 12 | 1295.12 | 2 | 15.14 | 2090 | 63 | 0.29 / 195.59 | 2 | 2 |
3 | 7 | 2002.20 | 31 | 14.71 | 2860 | 1304 | 1.59 / 196.89 | 2 | 3 |
4 | 13 | 1684.00 | 24 | 14.71 | 2496 | 881 | 2.48 / 197.77 | 2 | 3 |
5 | 13 | 952.08 | 24 | 14.87 | 1618 | 577 | 3.05 / 198.35 | 2 | 4 |
6 | 13 | 244.44 | 24 | 15.10 | 680 | 246 | 3.30 / 198.60 | 2 | 3 |
7 | 13 | 69.16 | 24 | 15.16 | 417 | 152 | 3.45 / 198.75 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.15 | 315 | 787 | 4.24 / 199.54 | 2 | 7 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 33 | 15.12 | 447 | 223 | 0.22 / 191.30 | 2 | 2 |
2 | 12 | 1161.56 | 2 | 15.17 | 1932 | 59 | 0.28 / 191.36 | 2 | 3 |
3 | 7 | 2003.56 | 31 | 14.73 | 2859 | 1306 | 1.59 / 192.67 | 3 | 4 |
4 | 13 | 1536.76 | 24 | 14.75 | 2335 | 827 | 2.41 / 193.49 | 2 | 3 |
5 | 13 | 1004.00 | 24 | 14.85 | 1673 | 596 | 3.01 / 194.09 | 2 | 4 |
6 | 13 | 276.24 | 24 | 15.09 | 720 | 261 | 3.27 / 194.35 | 2 | 3 |
7 | 13 | 67.48 | 24 | 15.16 | 422 | 154 | 3.42 / 194.50 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.14 | 318 | 794 | 4.22 / 195.30 | 2 | 8 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 33 | 15.12 | 455 | 227 | 0.23 / 187.17 | 2 | 2 |
2 | 12 | 1308.24 | 2 | 15.13 | 2111 | 64 | 0.29 / 187.23 | 2 | 2 |
3 | 7 | 2010.28 | 31 | 14.73 | 2865 | 1308 | 1.60 / 188.54 | 2 | 3 |
4 | 13 | 1553.96 | 24 | 14.74 | 2347 | 830 | 2.43 / 189.37 | 2 | 3 |
5 | 13 | 874.52 | 24 | 14.90 | 1507 | 539 | 2.97 / 189.91 | 2 | 4 |
6 | 13 | 196.52 | 24 | 15.12 | 617 | 224 | 3.19 / 190.13 | 2 | 3 |
7 | 13 | 50.56 | 24 | 15.17 | 403 | 147 | 3.34 / 190.28 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.15 | 319 | 797 | 4.14 / 191.08 | 2 | 9 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 32 | 15.13 | 446 | 216 | 0.22 / 182.90 | 2 | 2 |
2 | 3 | 1022.24 | 1 | 15.16 | 1772 | 27 | 0.24 / 182.93 | 2 | 2 |
3 | 12 | 1132.80 | 2 | 15.19 | 1885 | 57 | 0.30 / 182.99 | 2 | 2 |
4 | 7 | 2002.36 | 31 | 14.74 | 2875 | 1314 | 1.61 / 184.30 | 2 | 3 |
5 | 13 | 1667.84 | 24 | 14.72 | 2484 | 878 | 2.49 / 185.18 | 2 | 3 |
6 | 13 | 968.68 | 24 | 14.87 | 1629 | 581 | 3.07 / 185.76 | 2 | 4 |
7 | 13 | 251.52 | 24 | 15.11 | 692 | 251 | 3.32 / 186.01 | 2 | 3 |
8 | 13 | 66.84 | 24 | 15.17 | 415 | 151 | 3.47 / 186.16 | 2 | 3 |
9 | 8 | 0.16 | 165 | 15.15 | 313 | 782 | 4.26 / 186.94 | 2 | 8 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 32 | 15.12 | 453 | 219 | 0.22 / 178.66 | 2 | 2 |
2 | 12 | 1169.20 | 2 | 15.20 | 1933 | 59 | 0.28 / 178.72 | 2 | 2 |
3 | 7 | 2006.20 | 31 | 14.73 | 2859 | 1306 | 1.58 / 180.03 | 2 | 3 |
4 | 13 | 1704.08 | 24 | 14.72 | 2530 | 894 | 2.48 / 180.92 | 2 | 3 |
5 | 13 | 972.36 | 24 | 14.87 | 1633 | 583 | 3.06 / 181.50 | 2 | 4 |
6 | 13 | 261.16 | 24 | 15.11 | 699 | 253 | 3.31 / 181.76 | 2 | 3 |
7 | 13 | 78.44 | 24 | 15.17 | 430 | 157 | 3.47 / 181.91 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.16 | 309 | 773 | 4.24 / 182.69 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 32 | 15.12 | 452 | 219 | 0.22 / 174.37 | 2 | 2 |
2 | 12 | 1170.64 | 2 | 15.19 | 1943 | 59 | 0.28 / 174.43 | 2 | 2 |
3 | 7 | 2005.12 | 32 | 14.72 | 2870 | 1352 | 1.63 / 175.78 | 2 | 4 |
4 | 13 | 1683.28 | 24 | 14.72 | 2497 | 882 | 2.51 / 176.67 | 2 | 3 |
5 | 13 | 975.84 | 24 | 14.88 | 1636 | 584 | 3.10 / 177.25 | 2 | 3 |
6 | 13 | 250.04 | 24 | 15.11 | 688 | 249 | 3.35 / 177.50 | 2 | 3 |
7 | 13 | 64.08 | 24 | 15.17 | 417 | 152 | 3.50 / 177.65 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.15 | 316 | 790 | 4.29 / 178.44 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 32 | 15.13 | 453 | 219 | 0.22 / 170.18 | 2 | 2 |
2 | 12 | 1162.56 | 2 | 15.18 | 1930 | 59 | 0.28 / 170.24 | 2 | 2 |
3 | 7 | 2002.48 | 31 | 14.72 | 2868 | 1309 | 1.59 / 171.55 | 2 | 3 |
4 | 13 | 1530.04 | 24 | 14.76 | 2322 | 823 | 2.41 / 172.37 | 2 | 3 |
5 | 13 | 999.76 | 24 | 14.87 | 1668 | 595 | 3.00 / 172.96 | 2 | 3 |
6 | 13 | 245.44 | 24 | 15.11 | 676 | 245 | 3.25 / 173.21 | 2 | 3 |
7 | 13 | 61.52 | 24 | 15.17 | 415 | 151 | 3.40 / 173.36 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.16 | 318 | 795 | 4.20 / 174.16 | 2 | 9 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 32 | 15.16 | 449 | 218 | 0.22 / 165.92 | 2 | 2 |
2 | 12 | 1137.40 | 2 | 15.19 | 1897 | 58 | 0.28 / 165.98 | 2 | 2 |
3 | 7 | 2003.48 | 31 | 14.75 | 2856 | 1306 | 1.58 / 167.29 | 2 | 3 |
4 | 13 | 1691.72 | 24 | 14.72 | 2506 | 885 | 2.47 / 168.17 | 2 | 3 |
5 | 13 | 973.04 | 24 | 14.88 | 1639 | 585 | 3.05 / 168.76 | 2 | 4 |
6 | 13 | 268.68 | 24 | 15.10 | 717 | 260 | 3.31 / 169.02 | 2 | 4 |
7 | 13 | 72.48 | 24 | 15.17 | 430 | 157 | 3.47 / 169.17 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.16 | 314 | 785 | 4.25 / 169.96 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 33 | 15.13 | 458 | 229 | 0.23 / 162.36 | 2 | 2 |
2 | 12 | 1165.24 | 2 | 15.21 | 1929 | 59 | 0.29 / 162.42 | 2 | 2 |
3 | 7 | 1288.96 | 31 | 15.01 | 2006 | 933 | 1.22 / 163.35 | 2 | 3 |
4 | 13 | 1223.68 | 24 | 14.95 | 1941 | 696 | 1.92 / 164.05 | 2 | 3 |
5 | 13 | 740.12 | 24 | 15.02 | 1339 | 483 | 2.40 / 164.53 | 2 | 3 |
6 | 13 | 212.84 | 24 | 15.18 | 634 | 231 | 2.63 / 164.76 | 2 | 3 |
7 | 13 | 61.36 | 24 | 15.22 | 412 | 150 | 2.78 / 164.91 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.20 | 316 | 793 | 3.57 / 165.71 | 2 | 5 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 32 | 15.13 | 441 | 214 | 0.21 / 158.20 | 2 | 2 |
2 | 12 | 1154.08 | 2 | 15.20 | 1915 | 58 | 0.27 / 158.26 | 2 | 2 |
3 | 7 | 2004.24 | 31 | 14.73 | 2860 | 1306 | 1.58 / 159.57 | 2 | 3 |
4 | 13 | 1518.16 | 24 | 14.77 | 2297 | 814 | 2.39 / 160.38 | 2 | 3 |
5 | 13 | 840.68 | 24 | 14.93 | 1469 | 526 | 2.92 / 160.91 | 2 | 4 |
6 | 13 | 285.52 | 24 | 15.10 | 737 | 267 | 3.19 / 161.18 | 2 | 3 |
7 | 13 | 66.84 | 24 | 15.17 | 427 | 155 | 3.34 / 161.33 | 2 | 3 |
8 | 8 | 0.20 | 165 | 15.16 | 320 | 800 | 4.14 / 162.13 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 32 | 15.14 | 461 | 223 | 0.22 / 153.86 | 2 | 2 |
2 | 12 | 1153.24 | 2 | 15.21 | 1924 | 59 | 0.28 / 153.92 | 2 | 2 |
3 | 7 | 2011.80 | 32 | 14.74 | 2871 | 1354 | 1.64 / 155.27 | 2 | 3 |
4 | 13 | 1525.20 | 24 | 14.78 | 2313 | 820 | 2.46 / 156.09 | 2 | 3 |
5 | 13 | 993.80 | 24 | 14.88 | 1663 | 594 | 3.05 / 156.68 | 2 | 3 |
6 | 13 | 240.88 | 24 | 15.12 | 677 | 246 | 3.30 / 156.93 | 2 | 3 |
7 | 13 | 62.60 | 24 | 15.19 | 415 | 151 | 3.45 / 157.08 | 2 | 3 |
8 | 13 | 17.24 | 24 | 15.19 | 345 | 126 | 3.57 / 157.21 | 2 | 3 |
9 | 8 | 0.00 | 165 | 15.16 | 313 | 783 | 4.36 / 157.99 | 2 | 7 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 32 | 15.15 | 449 | 218 | 0.22 / 149.57 | 2 | 2 |
2 | 12 | 1155.40 | 2 | 15.21 | 1917 | 58 | 0.28 / 149.63 | 2 | 2 |
3 | 7 | 2003.20 | 31 | 14.75 | 2868 | 1311 | 1.59 / 150.94 | 2 | 3 |
4 | 13 | 1701.08 | 24 | 14.74 | 2515 | 890 | 2.48 / 151.83 | 2 | 3 |
5 | 13 | 963.60 | 24 | 14.90 | 1627 | 582 | 3.06 / 152.41 | 2 | 4 |
6 | 13 | 259.84 | 24 | 15.12 | 709 | 257 | 3.32 / 152.67 | 2 | 3 |
7 | 13 | 72.88 | 24 | 15.18 | 435 | 158 | 3.47 / 152.83 | 2 | 3 |
8 | 8 | 0.28 | 165 | 15.17 | 321 | 803 | 4.28 / 153.63 | 2 | 7 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 32 | 15.15 | 456 | 221 | 0.22 / 145.46 | 2 | 2 |
2 | 12 | 1157.08 | 2 | 15.22 | 1921 | 58 | 0.28 / 145.52 | 2 | 2 |
3 | 7 | 2005.40 | 31 | 14.76 | 2862 | 1310 | 1.59 / 146.83 | 2 | 2 |
4 | 13 | 1547.00 | 24 | 14.78 | 2332 | 827 | 2.42 / 147.66 | 2 | 4 |
5 | 13 | 865.24 | 24 | 14.93 | 1499 | 537 | 2.95 / 148.19 | 2 | 3 |
6 | 13 | 182.76 | 24 | 15.16 | 599 | 218 | 3.17 / 148.41 | 2 | 3 |
7 | 13 | 58.92 | 24 | 15.19 | 413 | 151 | 3.32 / 148.56 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.18 | 317 | 794 | 4.12 / 149.36 | 2 | 8 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 32 | 15.15 | 452 | 219 | 0.22 / 141.15 | 2 | 2 |
2 | 12 | 1136.80 | 2 | 15.23 | 1884 | 57 | 0.28 / 141.21 | 2 | 2 |
3 | 7 | 2006.84 | 31 | 14.76 | 2868 | 1312 | 1.59 / 142.52 | 2 | 2 |
4 | 13 | 1854.32 | 24 | 14.71 | 2713 | 958 | 2.55 / 143.48 | 2 | 4 |
5 | 13 | 926.16 | 24 | 14.92 | 1583 | 567 | 3.11 / 144.05 | 2 | 3 |
6 | 13 | 222.56 | 24 | 15.15 | 655 | 238 | 3.35 / 144.29 | 2 | 3 |
7 | 13 | 53.72 | 24 | 15.20 | 412 | 150 | 3.50 / 144.44 | 2 | 3 |
8 | 8 | 0.20 | 165 | 15.18 | 321 | 804 | 4.31 / 145.24 | 2 | 10 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 32 | 15.16 | 462 | 224 | 0.22 / 136.99 | 2 | 2 |
2 | 12 | 1142.68 | 2 | 15.21 | 1904 | 58 | 0.28 / 137.05 | 2 | 2 |
3 | 7 | 2002.48 | 32 | 14.76 | 2859 | 1350 | 1.63 / 138.40 | 2 | 2 |
4 | 13 | 1533.96 | 24 | 14.79 | 2326 | 826 | 2.46 / 139.23 | 2 | 4 |
5 | 13 | 862.72 | 24 | 14.94 | 1501 | 538 | 3.00 / 139.76 | 2 | 4 |
6 | 13 | 174.48 | 24 | 15.17 | 585 | 213 | 3.21 / 139.98 | 2 | 3 |
7 | 13 | 67.36 | 24 | 15.20 | 427 | 156 | 3.36 / 140.13 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.18 | 320 | 802 | 4.17 / 140.93 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 32 | 15.15 | 458 | 222 | 0.22 / 132.89 | 2 | 2 |
2 | 12 | 1142.52 | 2 | 15.22 | 1909 | 58 | 0.28 / 132.95 | 2 | 2 |
3 | 7 | 2003.64 | 31 | 14.76 | 2865 | 1311 | 1.59 / 134.26 | 2 | 3 |
4 | 13 | 1530.24 | 24 | 14.79 | 2324 | 825 | 2.42 / 135.08 | 2 | 4 |
5 | 13 | 834.16 | 24 | 14.95 | 1460 | 524 | 2.94 / 135.61 | 2 | 3 |
6 | 13 | 169.20 | 24 | 15.17 | 579 | 211 | 3.15 / 135.82 | 2 | 3 |
7 | 13 | 66.52 | 24 | 15.20 | 421 | 154 | 3.30 / 135.97 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.18 | 318 | 796 | 4.10 / 136.77 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 32 | 15.16 | 440 | 213 | 0.21 / 128.75 | 2 | 2 |
2 | 12 | 1153.68 | 2 | 15.22 | 1930 | 59 | 0.27 / 128.81 | 2 | 2 |
3 | 7 | 2002.16 | 32 | 14.76 | 2862 | 1352 | 1.62 / 130.16 | 2 | 3 |
4 | 13 | 1534.28 | 24 | 14.79 | 2321 | 824 | 2.45 / 130.98 | 2 | 3 |
5 | 13 | 853.92 | 24 | 14.95 | 1484 | 532 | 2.98 / 131.51 | 2 | 4 |
6 | 13 | 173.08 | 24 | 15.17 | 581 | 212 | 3.19 / 131.73 | 2 | 3 |
7 | 13 | 56.52 | 24 | 15.21 | 406 | 148 | 3.34 / 131.87 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.19 | 316 | 792 | 4.13 / 132.67 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 32 | 15.17 | 448 | 217 | 0.22 / 124.26 | 2 | 2 |
2 | 12 | 1311.56 | 2 | 15.18 | 2122 | 64 | 0.28 / 124.33 | 2 | 2 |
3 | 7 | 2007.76 | 31 | 14.76 | 2873 | 1315 | 1.60 / 125.64 | 2 | 3 |
4 | 13 | 1852.04 | 24 | 14.72 | 2704 | 955 | 2.55 / 126.60 | 2 | 3 |
5 | 13 | 1105.20 | 24 | 14.88 | 1796 | 641 | 3.19 / 127.24 | 2 | 4 |
6 | 13 | 194.76 | 24 | 15.17 | 615 | 224 | 3.42 / 127.46 | 2 | 3 |
7 | 13 | 71.68 | 24 | 15.21 | 429 | 157 | 3.57 / 127.62 | 2 | 3 |
8 | 13 | 19.56 | 24 | 15.22 | 350 | 128 | 3.70 / 127.75 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.19 | 314 | 787 | 4.49 / 128.53 | 2 | 11 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 32 | 15.17 | 460 | 223 | 0.22 / 120.03 | 2 | 2 |
2 | 12 | 1163.32 | 2 | 15.22 | 1927 | 59 | 0.28 / 120.09 | 2 | 2 |
3 | 7 | 2005.56 | 31 | 14.77 | 2864 | 1311 | 1.59 / 121.40 | 2 | 3 |
4 | 13 | 1675.56 | 24 | 14.77 | 2490 | 883 | 2.48 / 122.29 | 2 | 3 |
5 | 13 | 941.16 | 24 | 14.92 | 1596 | 571 | 3.05 / 122.86 | 2 | 3 |
6 | 13 | 217.72 | 24 | 15.16 | 645 | 235 | 3.28 / 123.09 | 2 | 3 |
7 | 13 | 72.60 | 24 | 15.21 | 429 | 157 | 3.44 / 123.25 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.20 | 318 | 798 | 4.24 / 124.05 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 32 | 15.17 | 465 | 226 | 0.23 / 115.81 | 2 | 2 |
2 | 10 | 1011.00 | 2 | 15.14 | 1707 | 52 | 0.28 / 115.86 | 2 | 3 |
3 | 3 | 954.00 | -1 | 15.52 | 3 | 0 | 0.05 / 115.86 | 2 | 3 |
4 | 12 | 1169.16 | 2 | 15.24 | 1948 | 59 | 0.34 / 115.92 | 2 | 2 |
5 | 7 | 2006.68 | 31 | 14.77 | 2866 | 1312 | 1.65 / 117.24 | 2 | 4 |
6 | 13 | 1680.44 | 24 | 14.76 | 2504 | 887 | 2.54 / 118.12 | 2 | 4 |
7 | 13 | 814.84 | 24 | 14.97 | 1440 | 517 | 3.05 / 118.64 | 2 | 4 |
8 | 13 | 175.80 | 24 | 15.18 | 579 | 211 | 3.26 / 118.85 | 2 | 3 |
9 | 13 | 62.84 | 24 | 15.22 | 420 | 153 | 3.42 / 119.00 | 2 | 3 |
10 | 8 | -0.12 | 165 | 15.20 | 321 | 805 | 4.22 / 119.81 | 2 | 7 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 32 | 15.18 | 457 | 222 | 0.22 / 111.65 | 2 | 2 |
2 | 12 | 1150.32 | 2 | 15.24 | 1915 | 58 | 0.28 / 111.71 | 2 | 2 |
3 | 7 | 2002.48 | 31 | 14.78 | 2865 | 1313 | 1.59 / 113.02 | 2 | 2 |
4 | 13 | 1670.08 | 24 | 14.78 | 2486 | 882 | 2.47 / 113.90 | 2 | 3 |
5 | 13 | 832.00 | 24 | 14.97 | 1461 | 525 | 3.00 / 114.43 | 2 | 3 |
6 | 13 | 185.56 | 24 | 15.18 | 590 | 215 | 3.21 / 114.64 | 2 | 3 |
7 | 13 | 67.88 | 24 | 15.22 | 421 | 154 | 3.37 / 114.79 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.21 | 316 | 793 | 4.16 / 115.59 | 2 | 9 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 32 | 15.16 | 460 | 223 | 0.22 / 107.52 | 2 | 2 |
2 | 12 | 1155.28 | 2 | 15.23 | 1935 | 59 | 0.28 / 107.58 | 2 | 2 |
3 | 7 | 2003.16 | 31 | 14.78 | 2872 | 1316 | 1.60 / 108.90 | 2 | 3 |
4 | 13 | 1526.92 | 24 | 14.81 | 2320 | 825 | 2.42 / 109.72 | 2 | 3 |
5 | 13 | 866.96 | 24 | 14.96 | 1508 | 541 | 2.96 / 110.26 | 2 | 3 |
6 | 13 | 186.88 | 24 | 15.18 | 596 | 217 | 3.18 / 110.48 | 2 | 3 |
7 | 13 | 63.76 | 24 | 15.22 | 414 | 151 | 3.33 / 110.63 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.21 | 316 | 793 | 4.13 / 111.43 | 2 | 6 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 32 | 15.17 | 447 | 217 | 0.22 / 103.08 | 2 | 2 |
2 | 12 | 1156.88 | 2 | 15.24 | 1932 | 59 | 0.28 / 103.14 | 2 | 2 |
3 | 7 | 2022.84 | 31 | 14.77 | 2890 | 1323 | 1.60 / 104.47 | 2 | 3 |
4 | 13 | 1873.76 | 24 | 14.73 | 2723 | 963 | 2.56 / 105.43 | 2 | 3 |
5 | 13 | 819.12 | 24 | 14.98 | 1441 | 518 | 3.08 / 105.95 | 2 | 4 |
6 | 13 | 271.00 | 24 | 15.15 | 723 | 263 | 3.34 / 106.21 | 2 | 4 |
7 | 13 | 78.04 | 24 | 15.21 | 442 | 161 | 3.50 / 106.37 | 2 | 3 |
8 | 13 | 22.36 | 24 | 15.22 | 359 | 131 | 3.64 / 106.50 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.19 | 318 | 797 | 4.43 / 107.30 | 2 | 7 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 32 | 15.18 | 449 | 218 | 0.22 / 98.77 | 2 | 2 |
2 | 12 | 1129.64 | 2 | 15.24 | 1897 | 58 | 0.28 / 98.83 | 2 | 2 |
3 | 7 | 2004.48 | 31 | 14.78 | 2858 | 1309 | 1.59 / 100.14 | 2 | 3 |
4 | 13 | 1688.28 | 24 | 14.78 | 2501 | 887 | 2.47 / 101.03 | 2 | 3 |
5 | 13 | 1114.36 | 24 | 14.89 | 1815 | 649 | 3.12 / 101.68 | 2 | 4 |
6 | 13 | 207.44 | 24 | 15.18 | 632 | 230 | 3.35 / 101.91 | 2 | 3 |
7 | 13 | 58.72 | 24 | 15.23 | 415 | 152 | 3.50 / 102.06 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.21 | 322 | 808 | 4.31 / 102.87 | 2 | 7 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 32 | 15.18 | 455 | 221 | 0.22 / 94.53 | 2 | 2 |
2 | 12 | 1151.16 | 2 | 15.24 | 1915 | 58 | 0.28 / 94.59 | 2 | 2 |
3 | 7 | 2001.08 | 31 | 14.79 | 2864 | 1313 | 1.59 / 95.90 | 2 | 3 |
4 | 13 | 1675.04 | 24 | 14.79 | 2484 | 882 | 2.47 / 96.78 | 2 | 3 |
5 | 13 | 944.80 | 24 | 14.95 | 1607 | 577 | 3.05 / 97.36 | 2 | 4 |
6 | 13 | 228.44 | 24 | 15.18 | 664 | 242 | 3.29 / 97.60 | 2 | 3 |
7 | 13 | 69.52 | 24 | 15.22 | 423 | 155 | 3.45 / 97.76 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.21 | 319 | 801 | 4.25 / 98.56 | 2 | 6 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 32 | 15.18 | 462 | 224 | 0.22 / 90.40 | 2 | 2 |
2 | 12 | 1156.08 | 2 | 15.26 | 1934 | 59 | 0.28 / 90.46 | 2 | 2 |
3 | 7 | 2002.36 | 31 | 14.78 | 2867 | 1314 | 1.60 / 91.77 | 2 | 2 |
4 | 13 | 1493.64 | 24 | 14.83 | 2288 | 814 | 2.41 / 92.58 | 2 | 3 |
5 | 13 | 801.96 | 24 | 15.00 | 1424 | 513 | 2.92 / 93.10 | 2 | 3 |
6 | 13 | 247.44 | 24 | 15.17 | 687 | 250 | 3.17 / 93.35 | 2 | 3 |
7 | 13 | 67.88 | 24 | 15.23 | 425 | 155 | 3.33 / 93.50 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.21 | 321 | 806 | 4.14 / 94.31 | 2 | 7 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 31 | 15.20 | 444 | 209 | 0.21 / 86.02 | 2 | 2 |
2 | 3 | 1018.60 | 1 | 15.25 | 1752 | 27 | 0.24 / 86.04 | 2 | 3 |
3 | 12 | 1290.56 | 2 | 15.21 | 2088 | 64 | 0.30 / 86.11 | 2 | 2 |
4 | 7 | 2005.96 | 31 | 14.79 | 2866 | 1314 | 1.61 / 87.42 | 2 | 2 |
5 | 13 | 1675.40 | 24 | 14.79 | 2503 | 888 | 2.50 / 88.31 | 2 | 4 |
6 | 13 | 1121.36 | 24 | 14.89 | 1833 | 655 | 3.16 / 88.96 | 2 | 4 |
7 | 13 | 215.44 | 24 | 15.18 | 650 | 237 | 3.39 / 89.20 | 2 | 3 |
8 | 13 | 61.72 | 24 | 15.23 | 428 | 156 | 3.55 / 89.36 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.21 | 325 | 816 | 4.37 / 90.17 | 2 | 8 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 31 | 15.19 | 455 | 214 | 0.21 / 81.87 | 2 | 2 |
2 | 12 | 1295.28 | 2 | 15.21 | 2094 | 64 | 0.28 / 81.93 | 2 | 2 |
3 | 7 | 2003.40 | 31 | 14.79 | 2856 | 1309 | 1.59 / 83.24 | 2 | 3 |
4 | 13 | 1702.28 | 24 | 14.79 | 2530 | 898 | 2.49 / 84.14 | 2 | 3 |
5 | 13 | 836.64 | 24 | 14.99 | 1464 | 527 | 3.01 / 84.66 | 2 | 4 |
6 | 13 | 178.76 | 24 | 15.21 | 588 | 215 | 3.23 / 84.88 | 2 | 3 |
7 | 13 | 59.00 | 24 | 15.24 | 404 | 148 | 3.37 / 85.03 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.23 | 311 | 782 | 4.16 / 85.81 | 2 | 5 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 31 | 15.19 | 455 | 214 | 0.21 / 77.61 | 2 | 2 |
2 | 12 | 1147.84 | 2 | 15.26 | 1920 | 59 | 0.27 / 77.67 | 2 | 2 |
3 | 7 | 2003.12 | 31 | 14.80 | 2875 | 1319 | 1.59 / 78.99 | 2 | 3 |
4 | 13 | 1667.80 | 24 | 14.80 | 2500 | 888 | 2.48 / 79.87 | 2 | 4 |
5 | 13 | 953.04 | 24 | 14.96 | 1623 | 583 | 3.06 / 80.46 | 2 | 3 |
6 | 13 | 242.72 | 24 | 15.18 | 679 | 247 | 3.31 / 80.70 | 2 | 3 |
7 | 13 | 61.20 | 24 | 15.24 | 412 | 151 | 3.46 / 80.86 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.22 | 317 | 796 | 4.26 / 81.65 | 2 | 8 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 31 | 15.21 | 454 | 214 | 0.21 / 73.35 | 2 | 2 |
2 | 12 | 1139.08 | 2 | 15.27 | 1904 | 58 | 0.27 / 73.41 | 2 | 2 |
3 | 7 | 2013.56 | 31 | 14.80 | 2890 | 1326 | 1.60 / 74.73 | 2 | 3 |
4 | 13 | 1543.52 | 24 | 14.83 | 2351 | 837 | 2.43 / 75.57 | 2 | 3 |
5 | 13 | 999.32 | 24 | 14.94 | 1682 | 603 | 3.04 / 76.17 | 2 | 3 |
6 | 13 | 250.60 | 24 | 15.18 | 693 | 252 | 3.29 / 76.43 | 2 | 3 |
7 | 13 | 62.88 | 24 | 15.24 | 425 | 155 | 3.45 / 76.58 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.22 | 324 | 814 | 4.26 / 77.39 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 31 | 15.21 | 449 | 212 | 0.21 / 69.12 | 2 | 2 |
2 | 12 | 1158.32 | 2 | 15.26 | 1924 | 59 | 0.27 / 69.18 | 2 | 2 |
3 | 7 | 2006.16 | 33 | 14.79 | 2869 | 1400 | 1.67 / 70.58 | 2 | 3 |
4 | 13 | 1521.32 | 23 | 14.84 | 2304 | 786 | 2.46 / 71.37 | 2 | 3 |
5 | 13 | 826.20 | 23 | 15.01 | 1449 | 500 | 2.96 / 71.87 | 2 | 4 |
6 | 13 | 178.44 | 23 | 15.22 | 581 | 203 | 3.16 / 72.07 | 2 | 3 |
7 | 13 | 56.56 | 23 | 15.25 | 408 | 143 | 3.30 / 72.21 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.23 | 319 | 802 | 4.11 / 73.02 | 2 | 7 |
9 | 14 | 0.16 | 25 | 15.21 | 312 | 119 | 4.22 / 73.14 | 2 | 9 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 31 | 15.22 | 447 | 211 | 0.21 / 65.02 | 2 | 2 |
2 | 12 | 1303.92 | 2 | 15.22 | 2103 | 64 | 0.27 / 65.08 | 2 | 2 |
3 | 7 | 2003.60 | 33 | 14.80 | 2852 | 1393 | 1.67 / 66.47 | 2 | 3 |
4 | 13 | 1525.44 | 23 | 14.84 | 2320 | 792 | 2.46 / 67.27 | 2 | 4 |
5 | 13 | 823.72 | 23 | 15.01 | 1447 | 500 | 2.96 / 67.77 | 2 | 4 |
6 | 13 | 174.80 | 23 | 15.22 | 582 | 204 | 3.16 / 67.97 | 2 | 3 |
7 | 13 | 54.44 | 23 | 15.26 | 403 | 141 | 3.30 / 68.11 | 2 | 2 |
8 | 8 | 0.20 | 165 | 15.24 | 318 | 800 | 4.10 / 68.91 | 2 | 5 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 31 | 15.20 | 462 | 218 | 0.22 / 60.94 | 2 | 2 |
2 | 12 | 1303.84 | 2 | 15.22 | 2127 | 65 | 0.28 / 61.01 | 2 | 2 |
3 | 7 | 2004.20 | 33 | 14.80 | 2870 | 1402 | 1.68 / 62.41 | 2 | 3 |
4 | 13 | 1505.24 | 23 | 14.86 | 2294 | 784 | 2.47 / 63.19 | 2 | 3 |
5 | 13 | 795.92 | 23 | 15.02 | 1414 | 488 | 2.96 / 63.68 | 2 | 4 |
6 | 13 | 159.40 | 23 | 15.23 | 553 | 194 | 3.15 / 63.88 | 2 | 3 |
7 | 13 | 49.64 | 23 | 15.26 | 395 | 139 | 3.29 / 64.01 | 2 | 3 |
8 | 8 | 0.20 | 165 | 15.24 | 315 | 792 | 4.08 / 64.81 | 2 | 5 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 31 | 15.21 | 458 | 216 | 0.22 / 56.77 | 2 | 2 |
2 | 12 | 1160.56 | 2 | 15.27 | 1938 | 59 | 0.28 / 56.83 | 2 | 2 |
3 | 7 | 2001.68 | 33 | 14.80 | 2865 | 1399 | 1.67 / 58.23 | 2 | 2 |
4 | 13 | 1523.88 | 23 | 14.86 | 2314 | 791 | 2.47 / 59.02 | 2 | 3 |
5 | 13 | 827.64 | 23 | 15.01 | 1450 | 501 | 2.97 / 59.52 | 2 | 4 |
6 | 13 | 260.40 | 23 | 15.18 | 710 | 248 | 3.21 / 59.77 | 2 | 3 |
7 | 13 | 63.16 | 23 | 15.25 | 424 | 149 | 3.36 / 59.91 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.23 | 323 | 812 | 4.17 / 60.73 | 2 | 5 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 31 | 15.22 | 454 | 214 | 0.21 / 52.65 | 2 | 2 |
2 | 12 | 1296.08 | 2 | 15.23 | 2128 | 65 | 0.28 / 52.72 | 2 | 2 |
3 | 7 | 2005.72 | 33 | 14.80 | 2868 | 1401 | 1.68 / 54.12 | 2 | 3 |
4 | 13 | 1503.20 | 23 | 14.87 | 2286 | 782 | 2.46 / 54.90 | 2 | 3 |
5 | 13 | 827.92 | 23 | 15.02 | 1459 | 504 | 2.97 / 55.40 | 2 | 3 |
6 | 13 | 165.32 | 23 | 15.23 | 569 | 199 | 3.16 / 55.60 | 2 | 3 |
7 | 13 | 59.88 | 23 | 15.26 | 415 | 146 | 3.31 / 55.75 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.24 | 319 | 802 | 4.11 / 56.55 | 2 | 7 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 31 | 15.21 | 459 | 216 | 0.22 / 48.58 | 2 | 2 |
2 | 12 | 1177.20 | 2 | 15.26 | 1960 | 60 | 0.28 / 48.64 | 2 | 2 |
3 | 7 | 2007.64 | 33 | 14.80 | 2873 | 1403 | 1.68 / 50.04 | 2 | 2 |
4 | 13 | 1384.00 | 23 | 14.90 | 2149 | 736 | 2.42 / 50.78 | 2 | 3 |
5 | 13 | 873.24 | 23 | 15.00 | 1515 | 523 | 2.94 / 51.30 | 2 | 4 |
6 | 13 | 179.80 | 23 | 15.23 | 585 | 205 | 3.14 / 51.50 | 2 | 3 |
7 | 13 | 67.52 | 23 | 15.27 | 419 | 147 | 3.29 / 51.65 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.25 | 313 | 788 | 4.08 / 52.44 | 2 | 5 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 31 | 15.22 | 465 | 219 | 0.22 / 44.34 | 2 | 2 |
2 | 12 | 1156.92 | 2 | 15.28 | 1923 | 59 | 0.28 / 44.40 | 2 | 2 |
3 | 7 | 2001.32 | 33 | 14.81 | 2871 | 1403 | 1.68 / 45.80 | 2 | 3 |
4 | 13 | 1491.40 | 23 | 14.88 | 2276 | 779 | 2.46 / 46.58 | 2 | 4 |
5 | 13 | 796.80 | 23 | 15.03 | 1415 | 489 | 2.95 / 47.07 | 2 | 4 |
6 | 13 | 164.72 | 23 | 15.24 | 568 | 199 | 3.15 / 47.27 | 2 | 3 |
7 | 13 | 86.12 | 23 | 15.25 | 453 | 159 | 3.31 / 47.43 | 2 | 3 |
8 | 13 | 22.72 | 23 | 15.27 | 360 | 126 | 3.43 / 47.55 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.24 | 321 | 807 | 4.24 / 48.36 | 2 | 8 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 31 | 15.23 | 457 | 216 | 0.22 / 40.23 | 2 | 2 |
2 | 12 | 1281.16 | 2 | 15.24 | 2078 | 63 | 0.28 / 40.29 | 2 | 2 |
3 | 7 | 2002.24 | 33 | 14.82 | 2863 | 1400 | 1.68 / 41.69 | 2 | 3 |
4 | 13 | 1500.84 | 18 | 14.91 | 2306 | 619 | 2.30 / 42.31 | 2 | 3 |
5 | 13 | 999.72 | 18 | 15.00 | 1683 | 454 | 2.75 / 42.76 | 2 | 4 |
6 | 13 | 480.48 | 18 | 15.13 | 1015 | 276 | 3.03 / 43.04 | 2 | 5 |
7 | 13 | 143.16 | 18 | 15.24 | 545 | 150 | 3.18 / 43.19 | 2 | 3 |
8 | 13 | 78.64 | 18 | 15.26 | 446 | 123 | 3.30 / 43.31 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.25 | 321 | 808 | 4.11 / 44.12 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 31 | 15.22 | 461 | 218 | 0.22 / 36.19 | 2 | 2 |
2 | 12 | 1149.40 | 2 | 15.29 | 1937 | 59 | 0.28 / 36.25 | 2 | 2 |
3 | 7 | 2002.24 | 33 | 14.82 | 2878 | 1408 | 1.68 / 37.66 | 2 | 4 |
4 | 13 | 1498.52 | 18 | 14.91 | 2295 | 616 | 2.30 / 38.28 | 2 | 4 |
5 | 13 | 987.00 | 18 | 15.01 | 1664 | 450 | 2.75 / 38.73 | 2 | 3 |
6 | 13 | 333.48 | 18 | 15.19 | 814 | 223 | 2.97 / 38.95 | 2 | 3 |
7 | 13 | 111.84 | 18 | 15.26 | 490 | 135 | 3.11 / 39.08 | 2 | 3 |
8 | 13 | 72.92 | 18 | 15.27 | 434 | 119 | 3.23 / 39.20 | 2 | 3 |
9 | 8 | 0.24 | 165 | 15.26 | 321 | 808 | 4.03 / 40.01 | 2 | 7 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 31 | 15.25 | 447 | 211 | 0.21 / 32.10 | 2 | 2 |
2 | 12 | 1310.88 | 2 | 15.24 | 2130 | 65 | 0.28 / 32.16 | 2 | 2 |
3 | 7 | 2004.00 | 33 | 14.83 | 2861 | 1400 | 1.68 / 33.56 | 2 | 3 |
4 | 13 | 1508.40 | 18 | 14.91 | 2302 | 618 | 2.29 / 34.18 | 2 | 3 |
5 | 13 | 983.36 | 18 | 15.01 | 1670 | 451 | 2.75 / 34.63 | 2 | 3 |
6 | 13 | 465.76 | 18 | 15.14 | 993 | 271 | 3.02 / 34.90 | 2 | 4 |
7 | 13 | 146.44 | 18 | 15.25 | 544 | 149 | 3.17 / 35.05 | 2 | 3 |
8 | 13 | 52.56 | 18 | 15.28 | 408 | 112 | 3.28 / 35.16 | 2 | 2 |
9 | 8 | 0.04 | 165 | 15.26 | 323 | 813 | 4.09 / 35.98 | 2 | 5 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 30 | 15.23 | 455 | 208 | 0.21 / 28.07 | 2 | 2 |
2 | 12 | 1301.80 | 3 | 15.22 | 2115 | 97 | 0.30 / 28.16 | 2 | 2 |
3 | 7 | 1986.80 | 33 | 14.82 | 2843 | 1390 | 1.69 / 29.55 | 2 | 4 |
4 | 13 | 1652.04 | 18 | 14.87 | 2464 | 660 | 2.35 / 30.21 | 2 | 3 |
5 | 13 | 946.76 | 18 | 15.02 | 1603 | 433 | 2.79 / 30.65 | 2 | 5 |
6 | 13 | 298.44 | 18 | 15.21 | 752 | 206 | 2.99 / 30.85 | 2 | 3 |
7 | 13 | 107.56 | 18 | 15.28 | 470 | 129 | 3.12 / 30.98 | 2 | 2 |
8 | 13 | 70.64 | 18 | 15.28 | 420 | 116 | 3.24 / 31.10 | 2 | 2 |
9 | 8 | 0.08 | 165 | 15.27 | 313 | 789 | 4.03 / 31.89 | 2 | 7 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 30 | 15.23 | 445 | 203 | 0.20 / 23.97 | 2 | 2 |
2 | 3 | 1020.92 | 1 | 15.29 | 1767 | 27 | 0.23 / 24.00 | 2 | 2 |
3 | 12 | 1307.60 | 3 | 15.23 | 2142 | 98 | 0.33 / 24.10 | 2 | 2 |
4 | 7 | 1984.32 | 34 | 14.82 | 2850 | 1436 | 1.76 / 25.54 | 2 | 3 |
5 | 13 | 1471.44 | 18 | 14.92 | 2263 | 608 | 2.37 / 26.14 | 2 | 3 |
6 | 13 | 949.96 | 18 | 15.02 | 1609 | 435 | 2.81 / 26.58 | 2 | 3 |
7 | 13 | 410.84 | 18 | 15.17 | 918 | 251 | 3.06 / 26.83 | 2 | 5 |
8 | 13 | 113.84 | 18 | 15.27 | 492 | 135 | 3.19 / 26.96 | 2 | 3 |
9 | 13 | 64.12 | 18 | 15.28 | 416 | 114 | 3.31 / 27.08 | 2 | 3 |
10 | 8 | 0.08 | 165 | 15.26 | 310 | 781 | 4.09 / 27.86 | 2 | 7 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 29 | 15.23 | 446 | 197 | 0.20 / 19.92 | 2 | 2 |
2 | 3 | 1041.84 | 1 | 15.24 | 1786 | 27 | 0.22 / 19.94 | 2 | 3 |
3 | 7 | 2007.36 | 34 | 14.84 | 2861 | 1444 | 1.67 / 21.39 | 3 | 4 |
4 | 13 | 1533.68 | 18 | 14.92 | 2327 | 625 | 2.29 / 22.01 | 2 | 3 |
5 | 13 | 1016.36 | 18 | 15.01 | 1690 | 457 | 2.75 / 22.47 | 2 | 3 |
6 | 13 | 497.40 | 18 | 15.14 | 1028 | 280 | 3.03 / 22.75 | 2 | 5 |
7 | 13 | 112.28 | 18 | 15.27 | 481 | 132 | 3.16 / 22.88 | 2 | 3 |
8 | 13 | 70.88 | 18 | 15.28 | 417 | 115 | 3.28 / 23.00 | 2 | 2 |
9 | 8 | 0.12 | 165 | 15.26 | 308 | 776 | 4.05 / 23.77 | 2 | 6 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 28 | 15.25 | 428 | 183 | 0.18 / 15.91 | 2 | 2 |
2 | 3 | 1047.76 | 1 | 15.24 | 1767 | 27 | 0.21 / 15.94 | 2 | 3 |
3 | 7 | 2004.64 | 33 | 14.86 | 2829 | 1387 | 1.60 / 17.33 | 3 | 3 |
4 | 13 | 1682.44 | 18 | 14.90 | 2482 | 666 | 2.26 / 17.99 | 2 | 3 |
5 | 13 | 984.28 | 18 | 15.03 | 1627 | 440 | 2.70 / 18.43 | 2 | 4 |
6 | 13 | 492.44 | 18 | 15.15 | 1003 | 274 | 2.98 / 18.71 | 2 | 6 |
7 | 13 | 147.08 | 18 | 15.26 | 519 | 143 | 3.12 / 18.85 | 2 | 3 |
8 | 13 | 79.44 | 18 | 15.27 | 420 | 115 | 3.23 / 18.96 | 2 | 3 |
9 | 8 | 0.00 | 165 | 15.27 | 300 | 756 | 3.99 / 19.72 | 2 | 7 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 29 | 15.25 | 419 | 185 | 0.19 / 12.51 | 2 | 2 |
2 | 7 | 1505.96 | 33 | 15.02 | 2236 | 1108 | 1.29 / 13.62 | 2 | 3 |
3 | 13 | 1360.20 | 18 | 15.02 | 2069 | 559 | 1.85 / 14.18 | 2 | 4 |
4 | 13 | 868.96 | 18 | 15.09 | 1476 | 401 | 2.25 / 14.58 | 2 | 3 |
5 | 13 | 240.24 | 18 | 15.26 | 648 | 178 | 2.43 / 14.76 | 2 | 3 |
6 | 13 | 130.72 | 18 | 15.29 | 488 | 134 | 2.57 / 14.89 | 2 | 2 |
7 | 13 | 68.88 | 18 | 15.30 | 396 | 109 | 2.68 / 15.00 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.29 | 289 | 729 | 3.40 / 15.73 | 2 | 5 |
Average= | 3.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 29 | 15.24 | 415 | 183 | 0.18 / 9.00 | 2 | 2 |
2 | 10 | 1004.52 | 2 | 15.20 | 1674 | 51 | 0.23 / 9.05 | 2 | 3 |
3 | 3 | 971.56 | -1 | 15.57 | 3 | 0 | 0.05 / 9.05 | 2 | 3 |
4 | 7 | 1526.96 | 34 | 15.01 | 2254 | 1150 | 1.38 / 10.20 | 3 | 3 |
5 | 13 | 1382.00 | 18 | 15.01 | 2095 | 566 | 1.95 / 10.77 | 2 | 3 |
6 | 13 | 848.80 | 18 | 15.10 | 1448 | 394 | 2.34 / 11.16 | 2 | 4 |
7 | 13 | 330.96 | 18 | 15.22 | 782 | 214 | 2.56 / 11.37 | 2 | 3 |
8 | 13 | 104.60 | 18 | 15.29 | 450 | 124 | 2.68 / 11.50 | 2 | 3 |
9 | 13 | 67.28 | 18 | 15.30 | 393 | 108 | 2.79 / 11.61 | 2 | 2 |
10 | 8 | 0.12 | 165 | 15.29 | 285 | 719 | 3.51 / 12.32 | 2 | 6 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 28 | 15.29 | 418 | 179 | 0.18 / 4.88 | 2 | 2 |
2 | 3 | 1028.68 | 1 | 15.30 | 1752 | 27 | 0.21 / 4.91 | 2 | 4 |
3 | 7 | 1513.60 | 74 | 14.91 | 2218 | 2447 | 2.65 / 7.36 | 4 | 3 |
4 | 13 | 280.88 | 18 | 15.24 | 707 | 194 | 2.85 / 7.55 | 2 | 3 |
5 | 13 | 103.68 | 18 | 15.30 | 446 | 123 | 2.97 / 7.68 | 2 | 2 |
6 | 13 | 63.72 | 18 | 15.30 | 384 | 106 | 3.08 / 7.78 | 2 | 2 |
7 | 8 | 0.04 | 240 | 15.27 | 282 | 1033 | 4.11 / 8.81 | 2 | 14 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 28 | 15.48 | 378 | 164 | 0.16 / 1.75 | 2 | 3 |
2 | 3 | 1021.00 | 1 | 15.33 | 1743 | 27 | 0.19 / 1.78 | 2 | 3 |
3 | 7 | 994.76 | 74 | 15.09 | 1588 | 1773 | 1.96 / 3.55 | 3 | 4 |
4 | 13 | 55.44 | 18 | 15.36 | 381 | 105 | 2.07 / 3.65 | 2 | 3 |
5 | 8 | 0.08 | 240 | 15.33 | 286 | 1052 | 3.12 / 4.71 | 2 | 12 |
Average= | 2.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 147.24 | 22 | 15.64 | 433 | 149 | 0.15 / 0.15 | 2 | 3 |
2 | 7 | 161.32 | 74 | 15.61 | 437 | 505 | 0.65 / 0.65 | 3 | 3 |
3 | 13 | 52.88 | 18 | 15.59 | 298 | 84 | 0.74 / 0.74 | 2 | 3 |
4 | 8 | 0.28 | 240 | 15.55 | 227 | 847 | 1.58 / 1.58 | 2 | 6 |
Average= | 1.58 (KJ/cycle) |