SIO Argo Site:
Pump Diagnostics Page   



Serial= 8647 WMO= 5905277

Return

←PreviousNext→

Cycle 255 GMT 20/12/2024 19:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 21 14.85 485 151 0.15 / 1049.17 2 2
2 12 1304.52 2 14.96 2270 68 0.22 / 1049.24 2 2
3 7 2003.48 30 14.58 3091 1352 1.57 / 1050.59 2 2
4 13 1516.12 31 14.55 2384 1075 2.65 / 1051.67 2 2
5 13 559.36 31 14.73 1119 511 3.16 / 1052.18 2 2
6 13 80.84 31 14.86 478 220 3.38 / 1052.40 2 2
7 8 0.04 165 14.85 343 840 4.22 / 1053.24 2 10
Average= 4.11
(KJ/cycle)

Cycle 254 GMT 10/12/2024 21: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 21 14.85 500 156 0.16 / 1045.00 2 2
2 12 1318.28 2 14.95 2318 69 0.23 / 1045.07 2 2
3 7 2003.32 30 14.57 3075 1344 1.57 / 1046.41 2 2
4 13 1506.52 31 14.54 2364 1066 2.63 / 1047.48 2 2
5 13 563.40 31 14.73 1111 507 3.14 / 1047.98 2 2
6 13 76.64 31 14.87 471 217 3.36 / 1048.20 2 2
7 8 -0.08 165 14.85 336 823 4.18 / 1049.02 2 4
Average= 4.11
(KJ/cycle)

Cycle 253 GMT 30/11/2024 22:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 21 14.85 500 156 0.16 / 1040.87 2 2
2 12 1309.88 2 14.96 2275 68 0.22 / 1040.94 2 2
3 7 2002.48 30 14.58 3059 1338 1.56 / 1042.27 2 2
4 13 1353.28 31 14.59 2135 966 2.53 / 1043.24 2 2
5 13 618.20 31 14.71 1191 543 3.07 / 1043.78 2 2
6 13 92.28 31 14.86 493 227 3.30 / 1044.01 2 2
7 8 0.04 165 14.85 339 831 4.13 / 1044.84 2 7
Average= 4.11
(KJ/cycle)

Cycle 252 GMT 21/11/2024 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 21 14.84 495 154 0.15 / 1036.66 2 2
2 12 1310.24 2 14.96 2282 68 0.22 / 1036.73 2 2
3 7 2007.44 30 14.58 3065 1341 1.56 / 1038.07 2 2
4 13 1515.60 31 14.54 2396 1080 2.64 / 1039.15 2 2
5 13 564.84 31 14.73 1121 512 3.16 / 1039.67 2 2
6 13 86.00 31 14.86 479 221 3.38 / 1039.89 2 2
7 8 0.08 165 14.86 337 826 4.20 / 1040.71 2 6
Average= 4.11
(KJ/cycle)

Cycle 251 GMT 11/11/2024 2:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 21 14.85 492 153 0.15 / 1032.33 2 2
2 12 1323.52 2 14.95 2306 69 0.22 / 1032.40 2 2
3 7 2003.92 30 14.58 3050 1334 1.56 / 1033.73 2 2
4 13 1522.04 31 14.55 2388 1077 2.63 / 1034.81 2 2
5 13 577.32 31 14.73 1130 516 3.15 / 1035.33 2 2
6 13 91.48 31 14.86 481 222 3.37 / 1035.55 2 2
7 8 0.08 165 14.86 332 814 4.19 / 1036.36 2 5
8 14 0.08 30 14.83 330 147 4.33 / 1036.51 2 8
Average= 4.11
(KJ/cycle)

Cycle 250 GMT 1/11/2024 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 21 14.85 495 154 0.15 / 1028.31 2 2
2 12 1303.32 2 14.96 2269 68 0.22 / 1028.38 2 2
3 7 2004.60 30 14.59 3031 1327 1.55 / 1029.71 2 2
4 13 1363.08 31 14.58 2181 986 2.53 / 1030.69 2 2
5 13 462.76 31 14.75 1007 460 3.00 / 1031.15 2 2
6 13 79.08 31 14.87 460 212 3.21 / 1031.37 2 2
7 8 0.08 165 14.86 331 812 4.02 / 1032.18 2 4
Average= 4.11
(KJ/cycle)

Cycle 249 GMT 22/10/2024 5:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 21 14.84 487 152 0.15 / 1024.09 2 2
2 12 1325.76 2 14.96 2312 69 0.22 / 1024.16 2 2
3 7 2006.92 31 14.59 3070 1389 1.61 / 1025.55 2 2
4 13 1525.24 31 14.55 2371 1069 2.68 / 1026.62 2 2
5 13 558.68 31 14.74 1101 503 3.18 / 1027.12 2 2
6 13 84.92 31 14.87 475 219 3.40 / 1027.34 2 2
7 8 0.08 165 14.86 333 816 4.22 / 1028.16 2 6
Average= 4.11
(KJ/cycle)

Cycle 248 GMT 12/10/2024 7:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 22 14.84 492 161 0.16 / 1019.84 2 2
2 12 1307.20 2 14.97 2289 69 0.23 / 1019.91 2 2
3 7 2005.20 31 14.58 3065 1385 1.61 / 1021.29 2 2
4 13 1509.68 31 14.55 2413 1088 2.70 / 1022.38 2 2
5 13 563.00 31 14.73 1119 511 3.21 / 1022.89 2 2
6 13 72.88 31 14.87 462 213 3.43 / 1023.10 2 2
7 8 0.04 165 14.85 342 838 4.26 / 1023.94 2 5
Average= 4.11
(KJ/cycle)

Cycle 247 GMT 2/10/2024 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 22 14.84 497 162 0.16 / 1015.53 2 2
2 12 1320.24 2 14.96 2291 69 0.23 / 1015.60 2 2
3 7 2004.56 30 14.60 3064 1342 1.57 / 1016.94 2 2
4 13 1682.96 31 14.53 2598 1170 2.74 / 1018.11 2 2
5 13 562.56 31 14.73 1122 512 3.26 / 1018.62 2 2
6 13 85.12 31 14.86 481 222 3.48 / 1018.84 2 2
7 8 0.08 165 14.86 340 834 4.31 / 1019.68 2 4
Average= 4.11
(KJ/cycle)

Cycle 246 GMT 22/ 9/2024 11:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 22 14.83 491 160 0.16 / 1011.26 2 2
2 12 1307.04 2 14.96 2280 68 0.23 / 1011.33 2 2
3 7 2003.56 30 14.59 3093 1354 1.58 / 1012.68 2 2
4 13 1521.20 31 14.55 2391 1078 2.66 / 1013.76 2 2
5 13 595.16 31 14.72 1159 529 3.19 / 1014.29 2 2
6 13 87.60 31 14.86 497 229 3.42 / 1014.52 2 2
7 8 0.08 165 14.86 345 846 4.26 / 1015.37 2 5
Average= 4.11
(KJ/cycle)

Cycle 245 GMT 12/ 9/2024 13:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 21 14.84 504 157 0.16 / 1007.06 2 2
2 12 1316.52 2 14.96 2285 68 0.23 / 1007.13 2 2
3 7 2006.16 30 14.59 3077 1347 1.57 / 1008.47 2 2
4 13 1509.64 31 14.57 2348 1061 2.63 / 1009.53 2 2
5 13 556.04 31 14.74 1114 509 3.14 / 1010.04 2 2
6 13 80.00 31 14.86 481 222 3.36 / 1010.26 2 2
7 8 -0.04 165 14.85 342 838 4.20 / 1011.10 2 7
Average= 4.11
(KJ/cycle)

Cycle 244 GMT 2/ 9/2024 15:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 21 14.83 504 157 0.16 / 1002.85 2 2
2 12 1302.60 2 14.96 2260 68 0.22 / 1002.92 2 2
3 7 2001.64 30 14.59 3051 1335 1.56 / 1004.26 2 2
4 13 1500.20 31 14.56 2384 1076 2.64 / 1005.33 2 2
5 13 566.84 31 14.73 1132 517 3.15 / 1005.85 2 2
6 13 72.44 31 14.87 466 215 3.37 / 1006.06 2 2
7 8 0.08 165 14.85 342 838 4.21 / 1006.90 2 5
Average= 4.11
(KJ/cycle)

Cycle 243 GMT 23/ 8/2024 17:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 21 14.84 494 154 0.15 / 998.58 2 2
2 12 1284.72 2 14.97 2221 66 0.22 / 998.65 2 2
3 7 2001.28 31 14.58 3091 1397 1.62 / 1000.05 2 2
4 13 1493.72 31 14.57 2352 1062 2.68 / 1001.11 2 2
5 13 556.60 31 14.73 1136 519 3.20 / 1001.63 2 2
6 13 77.56 31 14.87 473 218 3.42 / 1001.85 2 2
7 8 0.00 165 14.85 346 848 4.26 / 1002.70 2 7
Average= 4.11
(KJ/cycle)

Cycle 242 GMT 13/ 8/2024 19:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 22 14.85 495 162 0.16 / 994.33 2 2
2 12 1309.28 2 14.97 2264 68 0.23 / 994.40 2 2
3 7 2002.88 30 14.60 3088 1353 1.58 / 995.75 2 2
4 13 1508.24 31 14.56 2387 1077 2.66 / 996.83 2 2
5 13 584.56 31 14.72 1176 537 3.20 / 997.36 2 2
6 13 84.20 31 14.86 487 224 3.42 / 997.59 2 2
7 8 0.12 165 14.85 344 843 4.26 / 998.43 2 6
Average= 4.11
(KJ/cycle)

Cycle 241 GMT 3/ 8/2024 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 21 14.84 497 155 0.15 / 990.08 2 2
2 12 1307.12 2 14.96 2286 68 0.22 / 990.15 2 2
3 7 2005.88 31 14.58 3123 1412 1.63 / 991.56 2 2
4 13 1487.68 31 14.57 2353 1063 2.70 / 992.62 2 2
5 13 530.76 31 14.74 1098 502 3.20 / 993.12 2 2
6 13 85.80 31 14.87 476 219 3.42 / 993.34 2 2
7 8 0.08 165 14.86 337 826 4.25 / 994.17 2 6
Average= 4.11
(KJ/cycle)

Cycle 240 GMT 24/ 7/2024 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 21 14.83 503 157 0.16 / 985.81 2 2
2 12 1327.12 2 14.96 2281 68 0.22 / 985.88 2 2
3 7 2004.60 30 14.58 3068 1342 1.57 / 987.22 2 2
4 13 1663.12 31 14.53 2595 1169 2.74 / 988.39 2 2
5 13 511.04 31 14.75 1070 489 3.22 / 988.88 2 2
6 13 77.92 31 14.87 470 217 3.44 / 989.10 2 2
7 8 -0.04 165 14.86 337 826 4.27 / 989.92 2 5
Average= 4.11
(KJ/cycle)

Cycle 239 GMT 15/ 7/2024 1:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 22 14.85 498 163 0.16 / 981.61 2 2
2 12 1291.60 2 14.98 2249 67 0.23 / 981.68 2 2
3 7 2003.52 30 14.59 3078 1347 1.58 / 983.03 2 2
4 13 1499.00 31 14.57 2363 1067 2.64 / 984.09 2 2
5 13 545.04 31 14.73 1110 507 3.15 / 984.60 2 2
6 13 86.52 31 14.86 482 222 3.37 / 984.82 2 2
7 8 0.08 165 14.85 340 833 4.21 / 985.65 2 4
Average= 4.11
(KJ/cycle)

Cycle 238 GMT 5/ 7/2024 3:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 22 14.84 494 161 0.16 / 977.48 2 2
2 12 1304.52 2 14.98 2258 68 0.23 / 977.55 2 2
3 7 2006.44 30 14.60 3076 1347 1.58 / 978.90 2 2
4 13 1506.64 31 14.57 2384 1077 2.65 / 979.98 2 2
5 13 434.12 31 14.77 962 440 3.09 / 980.42 2 2
6 13 86.72 31 14.87 479 221 3.31 / 980.64 2 2
7 8 0.04 165 14.86 331 812 4.13 / 981.45 2 3
Average= 4.11
(KJ/cycle)

Cycle 237 GMT 25/ 6/2024 5:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 22 14.83 508 166 0.17 / 973.29 2 2
2 12 1311.92 2 14.97 2266 68 0.23 / 973.35 2 2
3 7 2002.16 30 14.61 3033 1329 1.56 / 974.68 2 2
4 13 1504.80 31 14.57 2373 1072 2.63 / 975.76 2 2
5 13 579.20 31 14.73 1146 523 3.16 / 976.28 2 2
6 13 96.64 31 14.86 489 225 3.38 / 976.50 2 2
7 8 -0.12 165 14.85 334 818 4.20 / 977.32 2 8
Average= 4.11
(KJ/cycle)

Cycle 236 GMT 15/ 6/2024 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 22 14.84 507 166 0.17 / 969.05 2 2
2 12 1304.88 2 14.98 2275 68 0.23 / 969.12 2 2
3 7 2005.16 30 14.59 3080 1348 1.58 / 970.47 2 2
4 13 1508.68 31 14.56 2391 1079 2.66 / 971.55 2 2
5 13 566.36 31 14.73 1138 520 3.18 / 972.07 2 2
6 13 95.68 31 14.86 492 227 3.41 / 972.29 2 2
7 8 -0.04 165 14.85 338 828 4.24 / 973.12 2 3
Average= 4.11
(KJ/cycle)

Cycle 235 GMT 5/ 6/2024 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 22 14.84 508 166 0.17 / 964.73 2 2
2 12 1320.24 2 14.96 2302 69 0.23 / 964.80 2 2
3 7 2007.28 30 14.61 3056 1339 1.57 / 966.14 2 2
4 13 1675.64 31 14.53 2620 1180 2.75 / 967.32 2 2
5 13 556.04 31 14.73 1121 512 3.27 / 967.83 2 2
6 13 103.72 31 14.86 503 232 3.50 / 968.06 2 2
7 8 0.00 165 14.85 337 826 4.32 / 968.88 2 3
Average= 4.11
(KJ/cycle)

Cycle 234 GMT 26/ 5/2024 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 22 14.83 508 166 0.17 / 960.47 2 2
2 12 1325.28 2 14.96 2327 70 0.24 / 960.54 2 2
3 7 2003.12 30 14.61 3062 1342 1.58 / 961.89 2 2
4 13 1510.92 31 14.57 2409 1088 2.67 / 962.97 2 2
5 13 573.68 31 14.73 1154 527 3.19 / 963.50 2 2
6 13 113.84 31 14.85 526 242 3.43 / 963.74 2 2
7 8 0.04 165 14.86 334 819 4.25 / 964.56 2 3
Average= 4.10
(KJ/cycle)

Cycle 233 GMT 16/ 5/2024 13: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 22 14.84 497 162 0.16 / 956.24 2 2
2 12 1303.12 2 14.97 2263 68 0.23 / 956.31 2 2
3 7 2005.92 30 14.59 3070 1344 1.57 / 957.65 2 2
4 13 1506.72 31 14.57 2371 1071 2.64 / 958.72 2 2
5 13 575.52 31 14.72 1155 527 3.17 / 959.25 2 2
6 13 98.52 31 14.86 505 233 3.40 / 959.48 2 2
7 8 -0.08 165 14.85 338 828 4.23 / 960.31 2 9
Average= 4.10
(KJ/cycle)

Cycle 232 GMT 6/ 5/2024 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 21 14.84 510 159 0.16 / 951.93 2 2
2 3 1022.76 1 14.93 1903 28 0.19 / 951.96 2 2
3 12 1319.84 2 14.97 2295 69 0.26 / 952.03 2 2
4 7 2002.04 30 14.61 3064 1343 1.60 / 953.37 2 2
5 13 1518.64 31 14.57 2389 1079 2.68 / 954.45 2 2
6 13 586.88 31 14.72 1170 534 3.21 / 954.99 2 2
7 13 107.20 31 14.85 526 242 3.45 / 955.23 2 2
8 8 0.00 165 14.85 345 845 4.30 / 956.08 2 8
Average= 4.10
(KJ/cycle)

Cycle 231 GMT 26/ 4/2024 16:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 21 14.83 504 157 0.16 / 947.68 2 2
2 12 1326.00 2 14.97 2310 69 0.23 / 947.74 2 2
3 7 2006.08 30 14.61 3069 1345 1.57 / 949.09 2 2
4 13 1520.32 31 14.56 2403 1085 2.66 / 950.17 2 2
5 13 573.72 31 14.73 1147 524 3.18 / 950.70 2 2
6 13 96.00 31 14.86 509 234 3.41 / 950.93 2 2
7 8 0.08 165 14.85 344 843 4.26 / 951.78 2 3
Average= 4.10
(KJ/cycle)

Cycle 230 GMT 16/ 4/2024 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 21 14.83 509 159 0.16 / 943.41 2 2
2 12 1313.68 2 14.98 2290 69 0.23 / 943.48 2 2
3 7 2007.36 30 14.59 3104 1359 1.59 / 944.84 2 2
4 13 1533.64 31 14.57 2394 1081 2.67 / 945.92 2 2
5 13 593.72 31 14.72 1167 533 3.20 / 946.45 2 2
6 13 101.48 31 14.85 512 236 3.44 / 946.69 2 2
7 8 0.08 165 14.85 340 833 4.27 / 947.52 2 3
Average= 4.10
(KJ/cycle)

Cycle 229 GMT 6/ 4/2024 20:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 21 14.84 498 155 0.16 / 939.13 2 2
2 12 1293.24 2 14.98 2254 68 0.22 / 939.20 2 2
3 7 2008.68 30 14.60 3101 1358 1.58 / 940.55 2 2
4 13 1521.88 31 14.58 2385 1078 2.66 / 941.63 2 2
5 13 603.32 31 14.72 1175 536 3.20 / 942.17 2 2
6 13 104.76 31 14.85 520 239 3.43 / 942.41 2 2
7 8 -0.08 165 14.85 344 843 4.28 / 943.25 2 4
Average= 4.10
(KJ/cycle)

Cycle 228 GMT 27/ 3/2024 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 21 14.83 508 158 0.16 / 934.95 2 2
2 12 1304.04 2 14.98 2245 67 0.23 / 935.02 2 2
3 7 2004.04 30 14.60 3057 1339 1.56 / 936.36 2 2
4 13 1468.12 31 14.59 2307 1043 2.61 / 937.40 2 2
5 13 549.44 31 14.74 1117 510 3.12 / 937.91 2 2
6 13 100.32 31 14.86 501 231 3.35 / 938.14 2 2
7 8 0.12 165 14.85 338 828 4.18 / 938.97 2 7
Average= 4.10
(KJ/cycle)

Cycle 227 GMT 18/ 3/2024 0:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 21 14.84 507 158 0.16 / 930.72 2 2
2 12 1298.12 2 14.97 2257 68 0.23 / 930.78 2 2
3 7 2003.52 30 14.60 3067 1343 1.57 / 932.13 2 2
4 13 1513.56 31 14.57 2395 1082 2.65 / 933.21 2 2
5 13 577.00 31 14.73 1138 520 3.17 / 933.73 2 2
6 13 103.76 31 14.85 508 234 3.40 / 933.96 2 2
7 8 0.12 165 14.85 340 833 4.24 / 934.80 2 5
Average= 4.10
(KJ/cycle)

Cycle 226 GMT 8/ 3/2024 1:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 21 14.83 503 157 0.16 / 926.64 2 2
2 12 1316.44 2 14.98 2272 68 0.22 / 926.71 2 2
3 7 2004.44 30 14.60 3050 1336 1.56 / 928.05 2 2
4 13 1365.48 31 14.60 2202 997 2.56 / 929.04 2 2
5 13 469.48 31 14.76 1009 462 3.02 / 929.50 2 2
6 13 95.00 31 14.86 495 228 3.25 / 929.73 2 2
7 8 0.04 165 14.85 337 826 4.07 / 930.56 2 3
Average= 4.10
(KJ/cycle)

Cycle 225 GMT 27/ 2/2024 3:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 21 14.84 503 157 0.16 / 922.35 2 2
2 12 1316.52 2 14.98 2304 69 0.23 / 922.42 2 2
3 7 2004.72 31 14.59 3092 1398 1.62 / 923.82 2 2
4 13 1521.68 31 14.56 2411 1088 2.71 / 924.91 2 2
5 13 559.00 31 14.73 1119 511 3.22 / 925.42 2 2
6 13 91.00 31 14.86 493 227 3.45 / 925.65 2 2
7 8 0.12 165 14.85 342 838 4.29 / 926.49 2 4
Average= 4.10
(KJ/cycle)

Cycle 224 GMT 17/ 2/2024 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 21 14.83 504 157 0.16 / 918.14 2 2
2 12 1305.48 2 14.98 2283 68 0.23 / 918.21 2 2
3 7 2002.72 30 14.60 3109 1362 1.59 / 919.57 2 2
4 13 1488.00 31 14.59 2321 1050 2.64 / 920.62 2 2
5 13 550.24 31 14.74 1107 506 3.14 / 921.13 2 2
6 13 82.24 31 14.86 483 222 3.37 / 921.35 2 2
7 8 0.04 165 14.85 345 845 4.21 / 922.20 2 7
Average= 4.10
(KJ/cycle)

Cycle 223 GMT 7/ 2/2024 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 21 14.82 506 157 0.16 / 913.90 2 2
2 12 1294.96 2 14.99 2260 68 0.23 / 913.97 2 2
3 7 2005.08 30 14.61 3088 1353 1.58 / 915.32 2 2
4 13 1511.72 31 14.58 2373 1073 2.65 / 916.39 2 2
5 13 583.96 31 14.73 1148 524 3.18 / 916.92 2 2
6 13 78.92 31 14.85 484 223 3.40 / 917.14 2 2
7 8 0.12 165 14.84 346 847 4.25 / 917.99 2 6
Average= 4.10
(KJ/cycle)

Cycle 222 GMT 28/ 1/2024 9:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 21 14.83 511 159 0.16 / 909.67 2 2
2 12 1297.16 2 14.98 2259 68 0.23 / 909.74 2 2
3 7 2001.60 30 14.60 3076 1347 1.57 / 911.09 2 2
4 13 1496.20 31 14.58 2378 1075 2.65 / 912.16 2 2
5 13 549.80 31 14.74 1104 504 3.15 / 912.67 2 2
6 13 80.92 31 14.86 485 223 3.38 / 912.89 2 2
7 8 0.08 165 14.85 348 853 4.23 / 913.74 2 4
Average= 4.10
(KJ/cycle)

Cycle 221 GMT 18/ 1/2024 10:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 21 14.82 515 160 0.16 / 905.34 2 2
2 12 1301.40 2 14.99 2256 68 0.23 / 905.40 2 2
3 7 2004.68 30 14.61 3086 1353 1.58 / 906.76 2 2
4 13 1683.48 31 14.54 2637 1189 2.77 / 907.95 2 2
5 13 533.00 31 14.74 1081 494 3.26 / 908.44 2 2
6 13 92.24 31 14.86 497 229 3.49 / 908.67 2 2
7 8 -0.12 165 14.85 344 843 4.33 / 909.51 2 5
Average= 4.10
(KJ/cycle)

Cycle 220 GMT 8/ 1/2024 12:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 21 14.83 509 159 0.16 / 901.06 2 2
2 12 1312.04 2 14.97 2295 69 0.23 / 901.13 2 2
3 7 2002.52 31 14.60 3081 1394 1.62 / 902.52 2 2
4 13 1515.84 31 14.58 2354 1064 2.69 / 903.58 2 2
5 13 567.36 31 14.74 1129 516 3.20 / 904.10 2 2
6 13 91.00 31 14.86 501 231 3.43 / 904.33 2 2
7 8 -0.04 165 14.85 345 845 4.28 / 905.18 2 3
Average= 4.10
(KJ/cycle)

Cycle 219 GMT 29/12/2023 14:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 21 14.83 511 159 0.16 / 896.86 2 2
2 12 1310.40 2 14.99 2277 68 0.23 / 896.93 2 2
3 7 2001.84 30 14.61 3023 1325 1.55 / 898.26 2 2
4 13 1490.44 31 14.59 2322 1050 2.60 / 899.31 2 2
5 13 566.40 31 14.73 1121 512 3.11 / 899.82 2 2
6 13 97.16 31 14.86 504 232 3.35 / 900.05 2 2
7 8 0.08 165 14.85 346 848 4.19 / 900.90 2 6
Average= 4.09
(KJ/cycle)

Cycle 218 GMT 19/12/2023 16:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 21 14.82 524 163 0.16 / 892.67 2 2
2 12 1320.64 2 14.98 2300 69 0.23 / 892.74 2 2
3 7 2003.08 30 14.61 3030 1328 1.56 / 894.06 2 2
4 13 1490.20 31 14.59 2324 1051 2.61 / 895.11 2 2
5 13 566.72 31 14.73 1139 520 3.13 / 895.63 2 2
6 13 91.16 31 14.86 494 228 3.36 / 895.86 2 2
7 8 0.08 165 14.85 344 843 4.20 / 896.70 2 5
Average= 4.09
(KJ/cycle)

Cycle 217 GMT 9/12/2023 18:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 21 14.83 503 157 0.16 / 888.45 2 2
2 12 1315.60 2 14.98 2263 68 0.22 / 888.52 2 2
3 7 2002.76 30 14.61 3060 1341 1.57 / 889.86 2 2
4 13 1493.32 31 14.59 2354 1065 2.63 / 890.93 2 2
5 13 545.88 31 14.74 1110 507 3.14 / 891.43 2 2
6 13 80.64 31 14.86 481 222 3.36 / 891.66 2 2
7 8 -0.04 165 14.85 346 848 4.21 / 892.50 2 10
Average= 4.09
(KJ/cycle)

Cycle 216 GMT 29/11/2023 20:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 21 14.83 501 156 0.16 / 884.23 2 2
2 12 1308.68 2 14.99 2268 68 0.22 / 884.30 2 2
3 7 2006.00 30 14.61 3098 1358 1.58 / 885.66 2 2
4 13 1500.76 31 14.59 2355 1065 2.65 / 886.72 2 2
5 13 560.16 31 14.73 1119 511 3.16 / 887.23 2 2
6 13 80.84 31 14.86 480 221 3.38 / 887.45 2 2
7 8 0.12 165 14.85 344 843 4.22 / 888.30 2 4
Average= 4.09
(KJ/cycle)

Cycle 215 GMT 19/11/2023 22:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 21 14.83 500 156 0.16 / 880.07 2 2
2 12 1302.08 2 14.98 2250 67 0.22 / 880.13 2 2
3 7 2002.52 30 14.62 3028 1328 1.55 / 881.46 2 2
4 13 1520.56 31 14.58 2406 1087 2.64 / 882.55 2 2
5 13 476.28 31 14.76 1012 463 3.10 / 883.01 2 2
6 13 73.28 31 14.86 468 216 3.32 / 883.23 2 2
7 8 -0.04 165 14.85 345 845 4.16 / 884.07 2 8
Average= 4.09
(KJ/cycle)

Cycle 214 GMT 10/11/2023 0:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 21 14.82 510 159 0.16 / 875.86 2 2
2 12 1314.36 2 14.98 2299 69 0.23 / 875.93 2 2
3 7 2003.60 30 14.61 3032 1329 1.56 / 877.26 2 2
4 13 1513.00 31 14.58 2375 1073 2.63 / 878.33 2 2
5 13 551.24 31 14.74 1111 508 3.14 / 878.84 2 2
6 13 77.80 31 14.86 484 223 3.36 / 879.06 2 2
7 8 0.00 165 14.84 347 850 4.21 / 879.91 2 3
Average= 4.09
(KJ/cycle)

Cycle 213 GMT 31/10/2023 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 21 14.83 502 156 0.16 / 871.58 2 2
2 12 1322.36 2 14.98 2305 69 0.23 / 871.65 2 2
3 7 2001.92 31 14.61 3070 1390 1.62 / 873.04 2 2
4 13 1511.32 31 14.59 2358 1066 2.68 / 874.11 2 2
5 13 579.24 31 14.73 1144 522 3.20 / 874.63 2 2
6 13 89.96 31 14.86 497 229 3.43 / 874.86 2 2
7 8 0.12 165 14.84 343 840 4.27 / 875.70 2 3
Average= 4.09
(KJ/cycle)

Cycle 212 GMT 21/10/2023 3:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 21 14.82 507 158 0.16 / 867.16 2 2
2 12 1304.16 2 14.99 2232 67 0.22 / 867.23 2 2
3 7 2005.16 30 14.61 3099 1358 1.58 / 868.59 2 2
4 13 1680.84 31 14.55 2625 1184 2.77 / 869.77 2 2
5 13 688.68 31 14.71 1281 584 3.35 / 870.36 2 2
6 13 90.36 31 14.86 496 228 3.58 / 870.58 2 2
7 8 -0.04 165 14.85 344 843 4.42 / 871.43 2 4
Average= 4.09
(KJ/cycle)

Cycle 211 GMT 11/10/2023 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 21 14.83 497 155 0.15 / 862.95 2 2
2 12 1329.60 2 14.99 2277 68 0.22 / 863.02 2 2
3 7 2003.04 30 14.61 3050 1337 1.56 / 864.36 2 2
4 13 1510.32 31 14.59 2353 1064 2.62 / 865.42 2 2
5 13 547.60 31 14.74 1124 514 3.14 / 865.94 2 2
6 13 75.92 31 14.86 480 221 3.36 / 866.16 2 2
7 8 0.00 165 14.84 346 847 4.21 / 867.01 2 4
Average= 4.09
(KJ/cycle)

Cycle 210 GMT 1/10/2023 7:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 21 14.82 501 156 0.16 / 858.71 2 2
2 12 1312.80 2 14.98 2282 68 0.22 / 858.78 2 2
3 7 2003.16 30 14.60 3096 1356 1.58 / 860.14 2 2
4 13 1504.80 31 14.58 2387 1079 2.66 / 861.21 2 2
5 13 553.64 31 14.73 1127 515 3.17 / 861.73 2 2
6 13 84.72 31 14.85 490 226 3.40 / 861.95 2 2
7 8 0.00 165 14.84 345 845 4.24 / 862.80 2 5
Average= 4.09
(KJ/cycle)

Cycle 209 GMT 21/ 9/2023 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 21 14.84 501 156 0.16 / 854.46 2 2
2 12 1294.32 2 14.98 2242 67 0.22 / 854.52 2 2
3 7 2003.68 31 14.61 3060 1386 1.61 / 855.91 2 2
4 13 1504.04 31 14.59 2349 1062 2.67 / 856.97 2 2
5 13 574.40 31 14.72 1134 517 3.19 / 857.49 2 2
6 13 91.04 31 14.85 496 228 3.42 / 857.72 2 2
7 8 0.00 165 14.84 342 837 4.25 / 858.55 2 6
Average= 4.09
(KJ/cycle)

Cycle 208 GMT 11/ 9/2023 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 21 14.83 494 154 0.15 / 850.16 2 2
2 12 1294.16 2 15.00 2244 67 0.22 / 850.23 2 2
3 7 2002.60 30 14.63 3072 1348 1.57 / 851.58 2 2
4 13 1659.28 31 14.56 2579 1164 2.73 / 852.74 2 2
5 13 540.04 31 14.74 1100 503 3.24 / 853.25 2 2
6 13 96.40 31 14.86 497 229 3.47 / 853.47 2 2
7 8 0.12 165 14.85 337 826 4.29 / 854.30 2 4
Average= 4.09
(KJ/cycle)

Cycle 207 GMT 1/ 9/2023 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 21 14.82 498 155 0.15 / 845.91 2 2
2 12 1312.76 2 14.98 2255 68 0.22 / 845.97 2 2
3 7 2002.64 30 14.62 3087 1354 1.58 / 847.33 2 2
4 13 1527.84 31 14.59 2378 1076 2.65 / 848.40 2 2
5 13 607.68 31 14.72 1185 541 3.19 / 848.94 2 2
6 13 112.40 31 14.85 524 241 3.43 / 849.19 2 2
7 8 0.12 165 14.85 336 823 4.26 / 850.01 2 3
Average= 4.09
(KJ/cycle)

Cycle 206 GMT 22/ 8/2023 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 21 14.83 500 156 0.16 / 841.63 2 2
2 12 1298.16 2 14.98 2227 67 0.22 / 841.70 2 2
3 7 2001.56 30 14.62 3054 1339 1.56 / 843.04 2 2
4 13 1504.16 31 14.60 2359 1068 2.63 / 844.10 2 2
5 13 709.64 31 14.70 1304 594 3.22 / 844.70 2 2
6 13 91.12 31 14.86 491 226 3.45 / 844.92 2 2
7 8 0.00 165 14.85 338 828 4.28 / 845.75 2 3
Average= 4.09
(KJ/cycle)

Cycle 205 GMT 12/ 8/2023 17: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 21 14.82 502 156 0.16 / 837.24 2 2
2 12 1302.52 2 15.00 2251 68 0.22 / 837.30 2 2
3 7 2003.44 30 14.63 3043 1336 1.56 / 838.64 2 2
4 13 1666.36 31 14.57 2568 1160 2.72 / 839.80 2 2
5 13 683.76 31 14.71 1270 579 3.30 / 840.38 2 2
6 13 117.48 31 14.84 547 252 3.55 / 840.63 2 2
7 8 0.00 165 14.84 345 845 4.39 / 841.47 2 3
Average= 4.08
(KJ/cycle)

Cycle 204 GMT 2/ 8/2023 18:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 21 14.83 516 161 0.16 / 833.03 2 2
2 12 1311.40 2 14.99 2276 68 0.23 / 833.09 2 2
3 7 2002.56 30 14.62 3032 1330 1.56 / 834.42 2 2
4 13 1510.12 31 14.60 2352 1065 2.62 / 835.49 2 2
5 13 574.28 31 14.73 1152 526 3.15 / 836.02 2 2
6 13 104.72 31 14.85 512 236 3.39 / 836.25 2 2
7 8 0.00 165 14.85 338 828 4.21 / 837.08 2 5
Average= 4.08
(KJ/cycle)

Cycle 203 GMT 23/ 7/2023 20:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 21 14.82 493 153 0.15 / 828.73 2 2
2 12 1307.24 2 14.99 2283 68 0.22 / 828.80 2 2
3 7 2002.80 30 14.63 3050 1339 1.56 / 830.13 2 2
4 13 1517.40 31 14.60 2362 1069 2.63 / 831.20 2 2
5 13 712.92 31 14.70 1310 597 3.23 / 831.80 2 2
6 13 117.64 31 14.85 525 242 3.47 / 832.04 2 2
7 8 0.16 165 14.85 336 823 4.29 / 832.87 2 3
Average= 4.08
(KJ/cycle)

Cycle 202 GMT 13/ 7/2023 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 21 14.83 505 157 0.16 / 824.50 2 2
2 12 1311.20 2 14.99 2251 67 0.22 / 824.57 2 2
3 7 2000.84 30 14.63 3075 1350 1.57 / 825.92 2 2
4 13 1507.96 31 14.60 2359 1068 2.64 / 826.99 2 2
5 13 575.48 31 14.73 1154 527 3.17 / 827.52 2 2
6 13 109.20 31 14.85 516 238 3.41 / 827.75 2 2
7 8 -0.04 165 14.85 335 821 4.23 / 828.57 2 8
Average= 4.08
(KJ/cycle)

Cycle 201 GMT 4/ 7/2023 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 21 14.82 503 157 0.16 / 820.29 2 2
2 12 1302.16 2 15.00 2281 68 0.22 / 820.36 2 2
3 7 2009.88 30 14.62 3046 1336 1.56 / 821.70 2 2
4 13 1510.68 31 14.60 2356 1066 2.63 / 822.76 2 2
5 13 557.00 31 14.74 1125 514 3.14 / 823.28 2 2
6 13 104.76 31 14.85 510 235 3.38 / 823.51 2 2
7 8 0.08 165 14.85 341 836 4.21 / 824.35 2 4
Average= 4.08
(KJ/cycle)

Cycle 200 GMT 24/ 6/2023 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 21 14.83 505 157 0.16 / 816.10 2 2
2 12 1315.84 2 14.99 2297 69 0.23 / 816.17 2 2
3 7 2003.52 30 14.62 3078 1350 1.58 / 817.52 2 2
4 13 1382.76 31 14.62 2196 995 2.57 / 818.52 2 2
5 13 628.84 31 14.72 1205 550 3.12 / 819.07 2 2
6 13 105.08 31 14.84 518 238 3.36 / 819.31 2 2
7 8 0.00 165 14.84 339 830 4.19 / 820.14 2 4
Average= 4.08
(KJ/cycle)

Cycle 199 GMT 14/ 6/2023 4:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 21 14.83 502 156 0.16 / 811.71 2 2
2 12 1309.84 2 14.99 2261 68 0.22 / 811.78 2 2
3 7 2005.32 30 14.63 3056 1341 1.57 / 813.12 2 2
4 13 1668.16 31 14.57 2622 1184 2.75 / 814.31 2 2
5 13 679.76 31 14.71 1274 581 3.33 / 814.89 2 2
6 13 97.32 31 14.86 496 228 3.56 / 815.11 2 2
7 8 0.16 165 14.85 339 831 4.39 / 815.95 2 5
Average= 4.08
(KJ/cycle)

Cycle 198 GMT 4/ 6/2023 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 21 14.82 508 158 0.16 / 807.46 2 2
2 12 1313.76 2 15.00 2267 68 0.23 / 807.53 2 2
3 7 2002.32 30 14.62 3097 1358 1.58 / 808.89 2 2
4 13 1510.64 31 14.61 2351 1065 2.65 / 809.95 2 2
5 13 581.76 31 14.73 1157 528 3.18 / 810.48 2 2
6 13 102.08 31 14.85 513 236 3.41 / 810.72 2 2
7 8 0.04 165 14.84 343 840 4.25 / 811.56 2 4
Average= 4.08
(KJ/cycle)

Cycle 197 GMT 25/ 5/2023 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 21 14.82 503 157 0.16 / 803.23 2 2
2 12 1313.20 2 15.00 2272 68 0.22 / 803.30 2 2
3 7 2001.20 30 14.64 3024 1328 1.55 / 804.63 2 2
4 13 1500.28 31 14.61 2340 1060 2.61 / 805.69 2 2
5 13 580.60 31 14.74 1149 525 3.14 / 806.22 2 2
6 13 85.16 31 14.85 494 227 3.37 / 806.44 2 2
7 8 0.00 165 14.84 351 859 4.22 / 807.30 2 5
Average= 4.08
(KJ/cycle)

Cycle 196 GMT 15/ 5/2023 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 21 14.82 513 160 0.16 / 798.87 2 2
2 3 1018.84 1 14.97 1925 29 0.19 / 798.90 2 2
3 12 1310.36 2 14.99 2267 68 0.26 / 798.97 2 2
4 7 2005.48 30 14.63 3073 1349 1.61 / 800.32 2 2
5 13 1514.16 31 14.60 2394 1084 2.69 / 801.40 2 2
6 13 728.04 31 14.70 1331 607 3.30 / 802.01 2 2
7 13 87.60 31 14.86 493 227 3.52 / 802.23 2 2
8 8 0.08 165 14.84 345 845 4.37 / 803.08 2 5
Average= 4.08
(KJ/cycle)

Cycle 195 GMT 5/ 5/2023 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 21 14.83 490 153 0.15 / 794.62 2 2
2 12 1304.96 2 15.01 2268 68 0.22 / 794.69 2 2
3 7 2006.20 30 14.62 3098 1359 1.58 / 796.05 2 2
4 13 1500.84 31 14.61 2362 1070 2.65 / 797.12 2 2
5 13 568.12 31 14.74 1149 525 3.17 / 797.64 2 2
6 13 95.72 31 14.85 500 230 3.40 / 797.87 2 2
7 8 0.04 165 14.84 342 837 4.24 / 798.71 2 5
Average= 4.08
(KJ/cycle)

Cycle 194 GMT 25/ 4/2023 14: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 21 14.82 508 158 0.16 / 790.23 2 2
2 12 1315.92 2 14.99 2296 69 0.23 / 790.30 2 2
3 7 2002.24 30 14.64 3039 1335 1.56 / 791.63 2 2
4 13 1513.84 31 14.61 2376 1076 2.64 / 792.71 2 2
5 13 576.12 31 14.74 1152 526 3.16 / 793.24 2 2
6 13 98.28 31 14.85 506 233 3.40 / 793.47 2 2
7 8 0.00 165 14.84 346 847 4.24 / 794.32 2 4
8 14 0.00 30 14.82 343 152 4.40 / 794.47 2 5
Average= 4.07
(KJ/cycle)

Cycle 193 GMT 15/ 4/2023 15:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 21 14.83 501 156 0.16 / 785.99 2 2
2 12 1319.04 2 15.00 2267 68 0.22 / 786.06 2 2
3 7 2005.20 30 14.61 3083 1351 1.58 / 787.41 2 2
4 13 1500.12 31 14.60 2371 1073 2.65 / 788.48 2 2
5 13 550.64 31 14.74 1127 515 3.16 / 789.00 2 2
6 13 90.36 31 14.86 495 228 3.39 / 789.23 2 2
7 8 -0.04 165 14.85 345 845 4.24 / 790.07 2 5
Average= 4.07
(KJ/cycle)

Cycle 192 GMT 5/ 4/2023 17:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 21 14.83 493 154 0.15 / 781.65 2 2
2 12 1303.84 2 15.00 2264 68 0.22 / 781.72 2 2
3 7 2006.16 30 14.62 3104 1361 1.58 / 783.08 2 2
4 13 1688.56 31 14.57 2614 1181 2.76 / 784.26 2 2
5 13 535.36 31 14.74 1096 501 3.26 / 784.76 2 2
6 13 107.60 31 14.85 516 238 3.50 / 785.00 2 2
7 8 0.00 165 14.85 340 833 4.33 / 785.84 2 3
Average= 4.07
(KJ/cycle)

Cycle 191 GMT 26/ 3/2023 19:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 21 14.82 511 159 0.16 / 777.42 2 2
2 12 1308.92 2 15.00 2291 69 0.23 / 777.48 2 2
3 7 2004.68 30 14.61 3099 1358 1.59 / 778.84 2 2
4 13 1502.40 31 14.60 2383 1079 2.66 / 779.92 2 2
5 13 545.76 31 14.74 1120 512 3.18 / 780.43 2 2
6 13 94.40 31 14.85 502 231 3.41 / 780.66 2 2
7 8 -0.04 165 14.85 341 836 4.24 / 781.50 2 4
Average= 4.07
(KJ/cycle)

Cycle 190 GMT 16/ 3/2023 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 21 14.82 503 157 0.16 / 773.18 2 2
2 12 1306.88 2 15.01 2265 68 0.22 / 773.25 2 2
3 7 2002.80 30 14.63 3064 1345 1.57 / 774.59 2 2
4 13 1499.60 31 14.61 2369 1073 2.64 / 775.66 2 2
5 13 569.32 31 14.74 1141 521 3.16 / 776.19 2 2
6 13 99.96 31 14.85 506 233 3.40 / 776.42 2 2
7 8 0.00 165 14.85 342 838 4.23 / 777.26 2 3
Average= 4.07
(KJ/cycle)

Cycle 189 GMT 6/ 3/2023 22:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 21 14.83 505 157 0.16 / 768.89 2 2
2 12 1321.80 2 14.99 2311 69 0.23 / 768.96 2 2
3 7 2002.56 31 14.62 3095 1403 1.63 / 770.36 2 2
4 13 1508.08 31 14.61 2374 1075 2.70 / 771.44 2 2
5 13 559.76 31 14.74 1126 515 3.22 / 771.95 2 2
6 13 99.60 31 14.86 506 233 3.45 / 772.18 2 2
7 8 0.08 165 14.85 342 838 4.29 / 773.02 2 6
Average= 4.07
(KJ/cycle)

Cycle 188 GMT 25/ 2/2023 0:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 21 14.83 502 156 0.16 / 764.69 2 2
2 12 1329.60 2 15.01 2291 69 0.23 / 764.75 2 2
3 7 2002.76 30 14.63 3060 1343 1.57 / 766.10 2 2
4 13 1488.16 31 14.61 2332 1056 2.62 / 767.15 2 2
5 13 540.76 31 14.75 1114 509 3.13 / 767.66 2 2
6 13 109.08 31 14.85 515 237 3.37 / 767.90 2 2
7 8 0.12 165 14.85 340 833 4.20 / 768.73 2 4
Average= 4.07
(KJ/cycle)

Cycle 187 GMT 15/ 2/2023 2:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 21 14.83 508 158 0.16 / 760.47 2 2
2 12 1321.56 2 15.01 2282 69 0.23 / 760.54 2 2
3 7 2005.12 30 14.63 3075 1350 1.58 / 761.89 2 2
4 13 1487.68 31 14.62 2346 1063 2.64 / 762.95 2 2
5 13 538.92 31 14.75 1118 511 3.15 / 763.46 2 2
6 13 102.80 31 14.85 515 237 3.39 / 763.70 2 2
7 8 0.04 165 14.85 339 831 4.22 / 764.53 2 6
Average= 4.07
(KJ/cycle)

Cycle 186 GMT 5/ 2/2023 4:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 21 14.82 498 155 0.15 / 756.31 2 2
2 12 1299.16 2 15.01 2238 67 0.22 / 756.37 2 2
3 7 2003.36 30 14.64 3079 1352 1.57 / 757.73 2 2
4 13 1507.72 31 14.61 2371 1074 2.65 / 758.80 2 2
5 13 460.72 31 14.78 1002 459 3.11 / 759.26 2 2
6 13 85.80 31 14.87 482 222 3.33 / 759.48 2 2
7 8 0.04 165 14.85 338 828 4.16 / 760.31 2 3
Average= 4.07
(KJ/cycle)

Cycle 185 GMT 26/ 1/2023 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 21 14.83 499 155 0.16 / 752.08 2 2
2 12 1319.84 2 15.00 2283 68 0.22 / 752.15 2 2
3 7 2001.72 30 14.63 3080 1352 1.58 / 753.50 2 2
4 13 1505.04 31 14.62 2351 1066 2.64 / 754.57 2 2
5 13 563.36 31 14.74 1134 518 3.16 / 755.09 2 2
6 13 78.16 31 14.86 478 220 3.38 / 755.31 2 2
7 8 0.04 165 14.85 345 845 4.22 / 756.15 2 7
Average= 4.07
(KJ/cycle)

Cycle 184 GMT 16/ 1/2023 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 21 14.82 503 157 0.16 / 747.86 2 2
2 12 1316.44 2 15.01 2282 69 0.23 / 747.93 2 2
3 7 2004.84 30 14.65 3060 1345 1.57 / 749.28 2 2
4 13 1509.56 31 14.62 2349 1065 2.63 / 750.34 2 2
5 13 578.32 31 14.75 1132 518 3.15 / 750.86 2 2
6 13 86.24 31 14.86 493 227 3.38 / 751.09 2 2
7 8 -0.04 165 14.85 343 840 4.22 / 751.93 2 4
Average= 4.06
(KJ/cycle)

Cycle 183 GMT 6/ 1/2023 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 21 14.82 502 156 0.16 / 743.61 2 2
2 12 1314.88 2 15.00 2272 68 0.22 / 743.68 2 2
3 7 2002.72 30 14.64 3081 1353 1.58 / 745.04 2 2
4 13 1517.16 31 14.62 2365 1072 2.65 / 746.11 2 2
5 13 597.04 31 14.74 1165 532 3.18 / 746.64 2 2
6 13 82.20 31 14.86 488 225 3.41 / 746.86 2 2
7 8 -0.04 165 14.85 344 843 4.25 / 747.71 2 4
Average= 4.06
(KJ/cycle)

Cycle 182 GMT 27/12/2022 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 21 14.83 507 158 0.16 / 739.41 2 2
2 12 1302.92 2 15.02 2243 67 0.23 / 739.48 2 2
3 7 2003.44 30 14.64 3069 1348 1.57 / 740.82 2 2
4 13 1499.16 31 14.61 2366 1072 2.64 / 741.90 2 2
5 13 542.28 31 14.76 1103 505 3.15 / 742.40 2 2
6 13 75.28 31 14.87 470 217 3.37 / 742.62 2 2
7 8 0.16 165 14.85 343 840 4.21 / 743.46 2 6
Average= 4.06
(KJ/cycle)

Cycle 181 GMT 17/12/2022 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 21 14.83 510 159 0.16 / 735.20 2 2
2 12 1322.52 2 15.01 2283 69 0.23 / 735.26 2 2
3 7 2006.60 30 14.64 3042 1336 1.56 / 736.60 2 2
4 13 1511.80 31 14.62 2349 1065 2.63 / 737.66 2 2
5 13 565.08 31 14.75 1127 515 3.14 / 738.18 2 2
6 13 82.08 31 14.86 486 224 3.37 / 738.40 2 2
7 8 -0.04 165 14.85 346 848 4.22 / 739.25 2 4
Average= 4.06
(KJ/cycle)

Cycle 180 GMT 7/12/2022 14:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 21 14.82 506 157 0.16 / 730.98 2 2
2 12 1298.32 2 15.02 2239 67 0.22 / 731.05 2 2
3 7 2003.60 30 14.64 3056 1342 1.57 / 732.39 2 2
4 13 1497.48 31 14.62 2338 1060 2.63 / 733.45 2 2
5 13 549.12 31 14.75 1113 509 3.14 / 733.96 2 2
6 13 81.20 31 14.87 486 224 3.36 / 734.18 2 2
7 8 0.00 165 14.85 349 855 4.21 / 735.04 2 6
Average= 4.06
(KJ/cycle)

Cycle 179 GMT 27/11/2022 16:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 21 14.83 501 156 0.16 / 726.74 2 2
2 12 1291.48 2 15.02 2240 67 0.22 / 726.81 2 2
3 7 2001.36 30 14.64 3076 1351 1.57 / 728.16 2 2
4 13 1498.40 31 14.62 2338 1060 2.63 / 729.22 2 2
5 13 575.16 31 14.75 1160 530 3.16 / 729.75 2 2
6 13 84.80 31 14.86 495 228 3.39 / 729.98 2 2
7 8 -0.08 165 14.85 345 845 4.24 / 730.82 2 5
Average= 4.06
(KJ/cycle)

Cycle 178 GMT 17/11/2022 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 21 14.82 503 157 0.16 / 722.45 2 2
2 12 1301.28 2 15.02 2240 67 0.22 / 722.51 2 2
3 7 2000.56 30 14.63 3072 1348 1.57 / 723.86 2 2
4 13 1649.32 31 14.58 2605 1177 2.75 / 725.04 2 2
5 13 512.20 31 14.76 1069 489 3.24 / 725.53 2 2
6 13 81.88 31 14.87 477 220 3.46 / 725.75 2 2
7 8 0.00 165 14.85 341 836 4.29 / 726.58 2 6
Average= 4.06
(KJ/cycle)

Cycle 177 GMT 7/11/2022 19:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 21 14.83 503 157 0.16 / 718.22 2 2
2 12 1318.32 2 15.00 2289 69 0.23 / 718.29 2 2
3 7 2002.56 30 14.65 3063 1346 1.57 / 719.63 2 2
4 13 1506.40 31 14.62 2355 1067 2.64 / 720.70 2 2
5 13 569.20 31 14.75 1151 526 3.17 / 721.23 2 2
6 13 90.24 31 14.86 495 228 3.39 / 721.45 2 2
7 8 0.08 165 14.85 341 836 4.23 / 722.29 2 3
Average= 4.06
(KJ/cycle)

Cycle 176 GMT 28/10/2022 21:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 21 14.84 502 156 0.16 / 713.93 2 2
2 12 1322.04 2 15.00 2314 69 0.23 / 714.00 2 2
3 7 2002.36 30 14.65 3026 1330 1.56 / 715.33 2 2
4 13 1672.64 31 14.59 2599 1176 2.73 / 716.50 2 2
5 13 546.48 31 14.76 1119 512 3.24 / 717.01 2 2
6 13 83.60 31 14.87 481 222 3.47 / 717.24 2 2
7 8 -0.04 165 14.86 337 826 4.29 / 718.06 2 6
Average= 4.06
(KJ/cycle)

Cycle 175 GMT 18/10/2022 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 21 14.83 502 156 0.16 / 709.56 2 2
2 12 1299.16 2 15.02 2260 68 0.22 / 709.62 2 2
3 7 2002.36 30 14.65 3058 1344 1.57 / 710.97 2 2
4 13 1676.76 31 14.60 2576 1166 2.73 / 712.13 2 2
5 13 682.20 31 14.73 1272 581 3.31 / 712.72 2 2
6 13 92.44 31 14.87 491 226 3.54 / 712.94 2 2
7 8 0.16 165 14.86 338 829 4.37 / 713.77 2 3
Average= 4.06
(KJ/cycle)

Cycle 174 GMT 9/10/2022 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 21 14.83 501 156 0.16 / 705.37 2 2
2 12 1315.36 2 15.01 2295 69 0.22 / 705.44 2 2
3 7 2002.84 30 14.65 3058 1344 1.57 / 706.78 2 2
4 13 1501.24 31 14.62 2344 1062 2.63 / 707.84 2 2
5 13 555.44 31 14.75 1118 511 3.14 / 708.35 2 2
6 13 79.56 31 14.87 470 217 3.36 / 708.57 2 2
7 8 0.12 165 14.85 339 831 4.19 / 709.40 2 7
Average= 4.05
(KJ/cycle)

Cycle 173 GMT 29/ 9/2022 2:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 21 14.83 502 156 0.16 / 701.06 2 2
2 12 1296.36 2 15.02 2219 67 0.22 / 701.12 2 2
3 7 2005.36 30 14.66 3034 1334 1.56 / 702.46 2 2
4 13 1521.76 31 14.62 2386 1081 2.64 / 703.54 2 2
5 13 741.84 31 14.72 1328 606 3.24 / 704.15 2 2
6 13 90.04 31 14.87 487 224 3.47 / 704.37 2 2
7 8 0.20 165 14.85 343 840 4.31 / 705.21 2 4
Average= 4.05
(KJ/cycle)

Cycle 172 GMT 19/ 9/2022 3:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 21 14.83 497 155 0.15 / 696.85 2 2
2 12 1285.60 2 15.02 2218 67 0.22 / 696.92 2 2
3 7 2001.04 30 14.64 3071 1349 1.57 / 698.27 2 2
4 13 1485.80 31 14.62 2361 1070 2.64 / 699.34 2 2
5 13 549.00 31 14.76 1114 510 3.15 / 699.85 2 2
6 13 79.48 31 14.87 475 219 3.37 / 700.06 2 2
7 8 0.00 165 14.86 341 836 4.21 / 700.90 2 4
Average= 4.05
(KJ/cycle)

Cycle 171 GMT 9/ 9/2022 5:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 21 14.84 495 154 0.15 / 692.68 2 2
2 12 1310.84 2 15.01 2249 68 0.22 / 692.74 2 2
3 7 2005.44 30 14.65 3084 1355 1.58 / 694.10 2 2
4 13 1528.08 31 14.61 2422 1097 2.67 / 695.20 2 2
5 13 445.12 31 14.79 968 444 3.12 / 695.64 2 2
6 13 69.00 31 14.87 462 213 3.33 / 695.85 2 2
7 8 0.04 165 14.85 344 843 4.17 / 696.70 2 5
Average= 4.05
(KJ/cycle)

Cycle 170 GMT 30/ 8/2022 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 21 14.83 505 157 0.16 / 688.42 2 2
2 12 1305.80 2 15.02 2293 69 0.23 / 688.49 2 2
3 7 2004.88 30 14.65 3084 1355 1.58 / 689.85 2 2
4 13 1521.80 31 14.62 2377 1077 2.66 / 690.92 2 2
5 13 575.84 31 14.75 1147 524 3.18 / 691.45 2 2
6 13 87.52 31 14.87 491 226 3.41 / 691.67 2 2
7 8 0.04 165 14.86 346 848 4.26 / 692.52 2 3
Average= 4.05
(KJ/cycle)

Cycle 169 GMT 20/ 8/2022 8:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 21 14.83 508 158 0.16 / 684.22 2 2
2 12 1317.48 2 15.01 2297 69 0.23 / 684.29 2 2
3 7 2002.08 30 14.66 3040 1337 1.56 / 685.62 2 2
4 13 1501.60 31 14.63 2375 1077 2.64 / 686.70 2 2
5 13 549.48 31 14.77 1107 507 3.15 / 687.21 2 2
6 13 79.40 31 14.87 476 219 3.37 / 687.43 2 2
7 8 0.04 165 14.86 341 836 4.20 / 688.26 2 5
Average= 4.05
(KJ/cycle)

Cycle 168 GMT 10/ 8/2022 10:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 21 14.83 495 154 0.15 / 679.96 2 2
2 12 1302.76 2 15.01 2294 69 0.22 / 680.03 2 2
3 7 2004.12 30 14.65 3067 1348 1.57 / 681.38 2 2
4 13 1520.08 31 14.61 2445 1107 2.68 / 682.48 2 2
5 13 561.16 31 14.76 1129 517 3.19 / 683.00 2 2
6 13 82.08 31 14.87 484 223 3.42 / 683.22 2 2
7 8 0.00 165 14.85 342 838 4.26 / 684.06 2 4
Average= 4.05
(KJ/cycle)

Cycle 167 GMT 31/ 7/2022 11:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 21 14.83 513 160 0.16 / 675.76 2 2
2 12 1311.60 2 15.02 2286 69 0.23 / 675.83 2 2
3 7 2004.60 31 14.64 3073 1395 1.62 / 677.22 2 2
4 13 1517.44 31 14.61 2383 1079 2.70 / 678.30 2 2
5 13 419.40 31 14.80 951 436 3.14 / 678.74 2 2
6 13 76.60 31 14.88 473 218 3.36 / 678.96 2 2
7 8 0.04 165 14.86 345 846 4.20 / 679.80 2 3
Average= 4.05
(KJ/cycle)

Cycle 166 GMT 21/ 7/2022 13:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 21 14.84 504 157 0.16 / 671.52 2 2
2 12 1296.48 2 15.03 2250 68 0.22 / 671.59 2 2
3 7 2001.48 30 14.66 3054 1343 1.57 / 672.93 2 2
4 13 1493.52 31 14.64 2341 1062 2.63 / 673.99 2 2
5 13 570.88 31 14.76 1152 527 3.16 / 674.52 2 2
6 13 95.40 31 14.87 503 232 3.39 / 674.75 2 2
7 8 0.04 165 14.86 346 848 4.24 / 675.60 2 8
Average= 4.05
(KJ/cycle)

Cycle 165 GMT 11/ 7/2022 15:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 21 14.84 504 157 0.16 / 667.19 2 2
2 12 1306.16 2 15.02 2267 68 0.23 / 667.25 2 2
3 7 2003.88 30 14.65 3096 1361 1.59 / 668.62 2 2
4 13 1510.40 31 14.63 2388 1083 2.67 / 669.70 2 2
5 13 721.84 31 14.73 1325 605 3.27 / 670.30 2 2
6 13 87.72 31 14.88 487 225 3.50 / 670.53 2 2
7 8 0.08 165 14.86 341 836 4.33 / 671.36 2 3
Average= 4.04
(KJ/cycle)

Cycle 164 GMT 1/ 7/2022 17:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 21 14.83 501 156 0.16 / 663.03 2 2
2 12 1304.60 2 15.03 2253 68 0.22 / 663.10 2 2
3 7 2000.92 30 14.65 3054 1342 1.57 / 664.44 2 2
4 13 1346.12 31 14.66 2130 968 2.53 / 665.41 2 2
5 13 601.12 31 14.75 1196 547 3.08 / 665.96 2 2
6 13 77.44 31 14.87 481 222 3.30 / 666.18 2 2
7 8 0.00 165 14.86 346 848 4.15 / 667.03 2 3
Average= 4.04
(KJ/cycle)

Cycle 163 GMT 21/ 6/2022 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 21 14.84 502 156 0.16 / 658.79 2 2
2 12 1311.04 2 15.03 2291 69 0.23 / 658.86 2 2
3 7 2002.60 30 14.66 3060 1346 1.57 / 660.21 2 2
4 13 1507.12 31 14.64 2362 1072 2.64 / 661.28 2 2
5 13 577.96 31 14.76 1148 525 3.17 / 661.81 2 2
6 13 78.84 31 14.88 480 221 3.39 / 662.03 2 2
7 8 0.00 165 14.86 347 851 4.24 / 662.88 2 3
Average= 4.04
(KJ/cycle)

Cycle 162 GMT 11/ 6/2022 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 21 14.84 501 156 0.16 / 654.59 2 2
2 12 1300.20 2 15.02 2268 68 0.22 / 654.66 2 2
3 7 2002.76 30 14.65 3049 1340 1.56 / 656.00 2 2
4 13 1485.48 31 14.64 2326 1056 2.62 / 657.05 2 2
5 13 554.00 31 14.77 1123 514 3.13 / 657.57 2 2
6 13 75.44 31 14.88 473 218 3.35 / 657.78 2 2
7 8 0.04 165 14.86 348 853 4.21 / 658.64 2 3
Average= 4.04
(KJ/cycle)

Cycle 161 GMT 1/ 6/2022 22:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 21 14.84 496 155 0.15 / 650.33 2 2
2 12 1297.84 2 15.02 2265 68 0.22 / 650.40 2 2
3 7 2002.28 31 14.64 3086 1401 1.62 / 651.80 2 2
4 13 1510.72 31 14.63 2341 1062 2.68 / 652.86 2 2
5 13 558.20 31 14.77 1125 515 3.20 / 653.38 2 2
6 13 75.80 31 14.88 471 217 3.42 / 653.59 2 2
7 8 0.04 165 14.86 342 839 4.26 / 654.43 2 5
Average= 4.04
(KJ/cycle)

Cycle 160 GMT 22/ 5/2022 23:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 21 14.84 499 156 0.16 / 646.09 2 2
2 12 1313.80 2 15.02 2257 68 0.22 / 646.16 2 2
3 7 2000.84 30 14.67 3059 1346 1.57 / 647.51 2 2
4 13 1524.36 31 14.64 2364 1073 2.64 / 648.58 2 2
5 13 580.52 31 14.76 1152 527 3.17 / 649.11 2 2
6 13 84.84 31 14.88 485 224 3.39 / 649.33 2 2
7 8 0.08 165 14.87 345 846 4.24 / 650.18 2 6
Average= 4.04
(KJ/cycle)

Cycle 159 GMT 13/ 5/2022 1:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 21 14.85 496 155 0.15 / 641.87 2 2
2 12 1296.44 2 15.02 2260 68 0.22 / 641.94 2 2
3 7 2002.64 30 14.65 3061 1345 1.57 / 643.28 2 2
4 13 1504.96 31 14.63 2387 1083 2.65 / 644.37 2 2
5 13 549.44 31 14.77 1109 508 3.16 / 644.88 2 2
6 13 81.64 31 14.88 483 223 3.38 / 645.10 2 2
7 8 -0.08 165 14.86 342 839 4.22 / 645.94 2 4
Average= 4.04
(KJ/cycle)

Cycle 158 GMT 3/ 5/2022 3:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 21 14.84 495 154 0.15 / 637.78 2 2
2 12 1299.60 2 15.04 2249 68 0.22 / 637.85 2 2
3 7 2001.04 30 14.65 3060 1345 1.57 / 639.20 2 2
4 13 1367.08 31 14.67 2159 982 2.55 / 640.18 2 2
5 13 497.56 31 14.78 1048 480 3.03 / 640.66 2 2
6 13 100.68 31 14.87 500 230 3.26 / 640.89 2 2
7 8 0.00 165 14.87 338 829 4.09 / 641.72 2 4
Average= 4.04
(KJ/cycle)

Cycle 157 GMT 23/ 4/2022 4:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 21 14.85 497 155 0.15 / 633.51 2 2
2 12 1304.48 2 15.02 2286 69 0.22 / 633.58 2 2
3 7 2005.04 31 14.65 3061 1390 1.61 / 634.97 2 2
4 13 1509.36 31 14.63 2354 1068 2.68 / 636.04 2 2
5 13 571.32 31 14.76 1142 523 3.20 / 636.56 2 2
6 13 106.08 31 14.87 514 237 3.44 / 636.80 2 2
7 8 0.00 165 14.86 339 831 4.27 / 637.63 2 5
Average= 4.04
(KJ/cycle)

Cycle 156 GMT 13/ 4/2022 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 21 14.84 501 156 0.16 / 629.18 2 2
2 12 1296.96 2 15.03 2266 68 0.22 / 629.25 2 2
3 7 2001.08 31 14.65 3064 1392 1.62 / 630.64 2 2
4 13 1660.04 31 14.61 2561 1160 2.78 / 631.80 2 2
5 13 528.72 31 14.78 1090 499 3.28 / 632.30 2 2
6 13 96.72 31 14.88 497 229 3.50 / 632.53 2 2
7 8 0.08 165 14.87 337 827 4.33 / 633.36 2 5
Average= 4.03
(KJ/cycle)

Cycle 155 GMT 3/ 4/2022 7:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 21 14.84 506 158 0.16 / 624.97 2 2
2 12 1275.00 2 15.03 2233 67 0.22 / 625.04 2 2
3 7 2005.36 30 14.65 3089 1358 1.58 / 626.40 2 2
4 13 1388.00 31 14.65 2210 1004 2.59 / 627.40 2 2
5 13 621.44 31 14.75 1200 549 3.13 / 627.95 2 2
6 13 101.88 31 14.87 510 235 3.37 / 628.18 2 2
7 8 -0.04 165 14.86 343 841 4.21 / 629.03 2 3
Average= 4.03
(KJ/cycle)

Cycle 154 GMT 24/ 3/2022 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 21 14.85 504 157 0.16 / 620.71 2 2
2 12 1289.76 2 15.03 2268 68 0.23 / 620.78 2 2
3 7 2004.24 31 14.66 3071 1396 1.62 / 622.18 2 2
4 13 1502.32 31 14.65 2336 1061 2.68 / 623.24 2 2
5 13 548.04 31 14.78 1118 512 3.19 / 623.75 2 2
6 13 87.32 31 14.88 486 224 3.42 / 623.97 2 2
7 8 -0.08 165 14.87 343 842 4.26 / 624.81 2 3
Average= 4.03
(KJ/cycle)

Cycle 153 GMT 14/ 3/2022 10:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 21 14.85 506 158 0.16 / 616.39 2 2
2 12 1314.20 2 15.04 2275 68 0.23 / 616.46 2 2
3 7 2003.84 30 14.67 3057 1345 1.57 / 617.80 2 2
4 13 1499.96 31 14.65 2366 1075 2.65 / 618.88 2 2
5 13 721.20 31 14.74 1317 602 3.25 / 619.48 2 2
6 13 104.88 31 14.88 512 236 3.48 / 619.72 2 2
7 8 0.12 165 14.87 342 839 4.32 / 620.55 2 3
Average= 4.03
(KJ/cycle)

Cycle 152 GMT 4/ 3/2022 12:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 21 14.85 501 156 0.16 / 612.14 2 2
2 12 1307.36 2 15.04 2283 69 0.22 / 612.21 2 2
3 7 2005.32 30 14.65 3110 1367 1.59 / 613.58 2 2
4 13 1498.68 31 14.64 2350 1067 2.66 / 614.64 2 2
5 13 556.56 31 14.78 1125 515 3.17 / 615.16 2 2
6 13 95.80 31 14.88 503 232 3.41 / 615.39 2 2
7 8 0.08 165 14.87 343 842 4.25 / 616.23 2 4
Average= 4.03
(KJ/cycle)

Cycle 151 GMT 22/ 2/2022 14:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 21 14.85 512 160 0.16 / 608.02 2 2
2 12 1317.96 2 15.03 2273 68 0.23 / 608.09 2 2
3 7 2003.40 30 14.67 3056 1345 1.57 / 609.43 2 2
4 13 1380.00 31 14.67 2180 991 2.56 / 610.43 2 2
5 13 496.04 31 14.79 1056 484 3.05 / 610.91 2 2
6 13 102.28 31 14.88 509 235 3.28 / 611.14 2 2
7 8 0.16 165 14.87 342 839 4.12 / 611.98 2 4
Average= 4.03
(KJ/cycle)

Cycle 150 GMT 12/ 2/2022 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 21 14.84 507 158 0.16 / 603.77 2 2
2 12 1306.00 2 15.03 2258 68 0.23 / 603.83 2 2
3 7 2001.48 31 14.66 3058 1390 1.62 / 605.22 2 2
4 13 1483.16 31 14.65 2336 1061 2.68 / 606.29 2 2
5 13 530.04 31 14.79 1085 497 3.17 / 606.78 2 2
6 13 95.92 31 14.89 502 232 3.41 / 607.01 2 2
7 8 0.04 165 14.88 345 847 4.25 / 607.86 2 3
Average= 4.03
(KJ/cycle)

Cycle 149 GMT 2/ 2/2022 17:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 21 14.85 495 154 0.15 / 599.49 2 2
2 12 1304.12 2 15.04 2248 68 0.22 / 599.56 2 2
3 7 2002.68 30 14.67 3066 1349 1.57 / 600.91 2 2
4 13 1525.20 31 14.64 2402 1090 2.66 / 602.00 2 2
5 13 591.04 31 14.77 1166 534 3.20 / 602.53 2 2
6 13 92.52 31 14.88 502 232 3.43 / 602.76 2 2
7 8 -0.08 165 14.87 345 846 4.27 / 603.61 2 7
Average= 4.02
(KJ/cycle)

Cycle 148 GMT 23/ 1/2022 19:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 21 14.86 499 156 0.16 / 595.33 2 2
2 12 1300.76 2 15.04 2273 68 0.22 / 595.40 2 2
3 7 2002.84 30 14.65 3085 1356 1.58 / 596.76 2 2
4 13 1336.68 31 14.68 2131 970 2.55 / 597.73 2 2
5 13 586.36 31 14.77 1172 537 3.09 / 598.26 2 2
6 13 94.56 31 14.88 502 232 3.32 / 598.49 2 2
7 8 0.08 165 14.87 343 842 4.16 / 599.34 2 5
Average= 4.02
(KJ/cycle)

Cycle 147 GMT 13/ 1/2022 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 21 14.85 506 158 0.16 / 590.93 2 2
2 12 1301.32 2 15.03 2257 68 0.23 / 591.00 2 2
3 7 2000.24 30 14.66 3043 1338 1.56 / 592.34 2 2
4 13 1663.60 31 14.61 2611 1183 2.75 / 593.52 2 2
5 13 655.48 31 14.76 1253 573 3.32 / 594.10 2 2
6 13 112.40 31 14.88 532 245 3.57 / 594.34 2 2
7 8 0.20 165 14.88 340 835 4.40 / 595.18 2 4
Average= 4.02
(KJ/cycle)

Cycle 146 GMT 3/ 1/2022 22:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 21 14.86 497 155 0.16 / 586.72 2 2
2 12 1302.48 2 15.03 2274 68 0.22 / 586.79 2 2
3 7 2002.64 30 14.66 3043 1338 1.56 / 588.13 2 2
4 13 1484.72 31 14.65 2346 1065 2.63 / 589.19 2 2
5 13 546.04 31 14.79 1115 511 3.14 / 589.70 2 2
6 13 89.92 31 14.90 496 229 3.37 / 589.93 2 2
7 8 0.00 165 14.88 343 842 4.21 / 590.78 2 6
Average= 4.02
(KJ/cycle)

Cycle 145 GMT 25/12/2021 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 21 14.86 502 157 0.16 / 582.58 2 2
2 12 1293.52 2 15.04 2228 67 0.22 / 582.65 2 2
3 7 2003.20 30 14.66 3092 1360 1.58 / 584.01 2 2
4 13 1502.48 31 14.66 2333 1060 2.64 / 585.07 2 2
5 13 437.16 31 14.82 961 442 3.09 / 585.51 2 2
6 13 77.04 31 14.90 472 218 3.30 / 585.73 2 2
7 8 0.04 165 14.89 342 840 4.14 / 586.57 2 3
Average= 4.02
(KJ/cycle)

Cycle 144 GMT 15/12/2021 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 21 14.86 505 158 0.16 / 578.34 2 2
2 3 1018.52 1 15.01 1918 29 0.19 / 578.37 2 2
3 12 1293.20 2 15.05 2266 68 0.25 / 578.44 2 2
4 7 2000.92 30 14.67 3034 1335 1.59 / 579.77 2 2
5 13 1506.40 31 14.65 2361 1072 2.66 / 580.85 2 2
6 13 550.40 31 14.79 1109 508 3.17 / 581.35 2 2
7 13 77.88 31 14.89 480 222 3.39 / 581.58 2 2
8 8 0.00 165 14.88 345 847 4.24 / 582.42 2 4
Average= 4.02
(KJ/cycle)

Cycle 143 GMT 5/12/2021 3:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 21 14.85 499 156 0.16 / 574.11 2 2
2 12 1310.88 2 15.04 2285 69 0.22 / 574.18 2 2
3 7 2002.88 30 14.66 3060 1346 1.57 / 575.53 2 2
4 13 1499.80 31 14.66 2341 1064 2.63 / 576.59 2 2
5 13 553.36 31 14.79 1129 518 3.15 / 577.11 2 2
6 13 82.28 31 14.90 485 224 3.38 / 577.33 2 2
7 8 0.12 165 14.89 347 853 4.23 / 578.18 2 3
Average= 4.02
(KJ/cycle)

Cycle 142 GMT 25/11/2021 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 21 14.85 502 157 0.16 / 569.80 2 2
2 12 1313.28 2 15.03 2279 69 0.23 / 569.86 2 2
3 7 2003.52 28 14.70 3086 1270 1.50 / 571.13 2 2
4 13 1517.92 30 14.66 2392 1052 2.55 / 572.19 2 2
5 13 594.28 30 14.79 1177 522 3.07 / 572.71 2 2
6 13 86.24 30 14.90 496 222 3.29 / 572.93 2 2
7 13 18.44 30 14.91 383 171 3.46 / 573.10 2 2
8 8 -0.04 165 14.87 348 854 4.32 / 573.96 2 6
Average= 4.01
(KJ/cycle)

Cycle 141 GMT 15/11/2021 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 21 14.85 491 153 0.15 / 565.41 2 2
2 12 1310.76 2 15.03 2260 68 0.22 / 565.48 2 2
3 7 2000.68 28 14.69 3068 1262 1.48 / 566.74 2 2
4 13 1514.08 30 14.66 2391 1052 2.53 / 567.79 2 2
5 13 762.88 30 14.75 1366 604 3.14 / 568.40 2 2
6 13 76.20 30 14.90 485 217 3.36 / 568.61 2 2
7 13 19.48 30 14.91 385 172 3.53 / 568.79 2 2
8 8 -0.08 165 14.87 348 854 4.38 / 569.64 2 8
Average= 4.01
(KJ/cycle)

Cycle 140 GMT 5/11/2021 8:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 21 14.85 503 157 0.16 / 561.07 2 2
2 12 1306.40 2 15.04 2277 68 0.23 / 561.13 2 2
3 7 2003.12 29 14.68 3063 1304 1.53 / 562.44 2 2
4 13 1516.16 30 14.66 2370 1042 2.57 / 563.48 2 2
5 13 600.68 30 14.78 1193 529 3.10 / 564.01 2 2
6 13 92.60 30 14.89 506 226 3.33 / 564.24 2 2
7 13 20.24 30 14.91 385 172 3.50 / 564.41 2 2
8 8 -0.08 165 14.87 346 849 4.35 / 565.26 2 6
Average= 4.01
(KJ/cycle)

Cycle 139 GMT 26/10/2021 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 21 14.87 496 155 0.15 / 556.74 2 2
2 12 1302.20 2 15.06 2231 67 0.22 / 556.81 2 2
3 7 2002.56 30 14.69 3069 1353 1.57 / 558.16 2 2
4 13 1490.08 29 14.66 2348 998 2.57 / 559.16 2 2
5 13 603.04 29 14.79 1191 511 3.08 / 559.67 2 2
6 13 93.16 29 14.90 505 218 3.30 / 559.89 2 2
7 13 21.64 29 14.91 387 167 3.47 / 560.06 2 2
8 8 -0.04 165 14.87 347 851 4.32 / 560.91 2 8
Average= 4.01
(KJ/cycle)

Cycle 138 GMT 16/10/2021 10:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 21 14.86 512 160 0.16 / 552.72 2 2
2 12 1308.32 2 15.04 2292 69 0.23 / 552.79 2 2
3 7 2000.92 30 14.67 3067 1350 1.58 / 554.14 2 2
4 13 1367.36 29 14.68 2196 935 2.51 / 555.08 2 2
5 13 495.56 29 14.82 1044 449 2.96 / 555.53 2 2
6 13 76.44 29 14.91 478 207 3.17 / 555.73 2 2
7 8 0.08 165 14.89 348 855 4.02 / 556.59 2 6
Average= 4.00
(KJ/cycle)

Cycle 137 GMT 6/10/2021 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 21 14.88 508 159 0.16 / 548.56 2 2
2 12 1309.84 2 15.04 2257 68 0.23 / 548.63 2 2
3 7 2002.40 30 14.65 3104 1364 1.59 / 550.00 2 2
4 13 1505.40 29 14.66 2359 1003 2.59 / 551.00 2 2
5 13 574.64 29 14.79 1160 498 3.09 / 551.50 2 2
6 13 88.36 29 14.90 501 216 3.31 / 551.71 2 2
7 8 0.00 165 14.89 347 853 4.16 / 552.56 2 5
Average= 4.00
(KJ/cycle)

Cycle 136 GMT 26/ 9/2021 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 21 14.86 497 155 0.16 / 544.47 2 2
2 12 1324.48 2 15.04 2292 69 0.22 / 544.53 2 2
3 7 2003.76 31 14.67 3052 1388 1.61 / 545.92 2 2
4 13 1483.20 28 14.66 2333 958 2.57 / 546.88 2 2
5 13 565.64 28 14.80 1151 477 3.05 / 547.36 2 2
6 13 113.16 28 14.90 524 219 3.27 / 547.58 2 2
7 8 0.16 165 14.90 337 829 4.09 / 548.40 2 5
Average= 4.00
(KJ/cycle)

Cycle 135 GMT 16/ 9/2021 14:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 21 14.88 499 156 0.16 / 540.27 2 2
2 12 1304.76 2 15.03 2274 68 0.22 / 540.33 2 2
3 7 2002.76 31 14.66 3015 1370 1.59 / 541.70 2 2
4 13 1355.60 28 14.68 2175 894 2.49 / 542.60 2 2
5 13 628.88 28 14.78 1204 498 2.99 / 543.10 2 2
6 13 107.56 28 14.90 526 219 3.21 / 543.32 2 2
7 13 24.68 28 14.92 383 160 3.37 / 543.48 2 2
8 8 -0.08 165 14.88 340 835 4.20 / 544.31 2 4
Average= 4.00
(KJ/cycle)

Cycle 134 GMT 6/ 9/2021 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 21 14.87 495 155 0.15 / 536.16 2 2
2 12 1319.52 2 15.05 2276 69 0.22 / 536.23 2 2
3 7 2001.84 31 14.66 3085 1402 1.63 / 537.63 2 2
4 13 1469.36 28 14.67 2336 960 2.58 / 538.59 2 2
5 13 565.44 28 14.80 1144 474 3.06 / 539.06 2 2
6 13 99.40 28 14.91 512 214 3.27 / 539.28 2 2
7 8 0.04 165 14.91 338 832 4.10 / 540.11 2 4
Average= 4.00
(KJ/cycle)

Cycle 133 GMT 27/ 8/2021 17:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 21 14.87 499 156 0.16 / 531.90 2 2
2 12 1302.92 2 15.05 2258 68 0.22 / 531.97 2 2
3 7 2004.08 30 14.68 3082 1357 1.58 / 533.33 2 2
4 13 1505.52 27 14.68 2364 937 2.52 / 534.27 2 2
5 13 747.80 27 14.77 1355 540 3.06 / 534.81 2 2
6 13 97.32 27 14.92 508 205 3.26 / 535.01 2 2
7 13 29.76 27 14.93 394 159 3.42 / 535.17 2 2
8 8 0.04 165 14.90 340 836 4.26 / 536.01 2 6
Average= 4.00
(KJ/cycle)

Cycle 132 GMT 17/ 8/2021 19:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 21 14.88 501 157 0.16 / 527.63 2 2
2 12 1287.56 2 15.05 2214 67 0.22 / 527.70 2 2
3 7 2001.72 31 14.66 3098 1408 1.63 / 529.11 2 2
4 13 1499.60 27 14.68 2355 933 2.56 / 530.04 2 2
5 13 615.52 27 14.79 1194 477 3.04 / 530.52 2 2
6 13 109.36 27 14.91 530 213 3.25 / 530.73 2 2
7 13 26.64 27 14.93 401 162 3.42 / 530.89 2 2
8 8 -0.08 165 14.89 348 855 4.27 / 531.75 2 7
Average= 4.00
(KJ/cycle)

Cycle 131 GMT 7/ 8/2021 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 21 14.88 495 155 0.15 / 523.40 2 2
2 12 1292.92 2 15.05 2214 67 0.22 / 523.46 2 2
3 7 2000.56 30 14.67 3058 1346 1.57 / 524.81 2 2
4 13 1494.20 27 14.67 2353 932 2.50 / 525.74 2 2
5 13 729.28 27 14.78 1326 529 3.03 / 526.27 2 2
6 13 107.40 27 14.92 520 209 3.24 / 526.48 2 2
7 13 29.08 27 14.93 393 158 3.40 / 526.64 2 2
8 8 0.08 165 14.90 341 838 4.23 / 527.48 2 6
Average= 4.00
(KJ/cycle)

Cycle 130 GMT 28/ 7/2021 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 21 14.89 501 157 0.16 / 519.26 2 2
2 12 1301.68 2 15.05 2227 67 0.22 / 519.32 2 2
3 7 2002.72 31 14.67 3064 1393 1.62 / 520.72 2 2
4 13 1500.84 27 14.67 2381 943 2.56 / 521.66 2 2
5 13 750.12 27 14.77 1362 543 3.10 / 522.20 2 2
6 13 97.24 27 14.91 510 205 3.31 / 522.41 2 2
7 8 0.12 165 14.91 339 834 4.14 / 523.24 2 4
Average= 3.99
(KJ/cycle)

Cycle 129 GMT 19/ 7/2021 0:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 21 14.89 504 158 0.16 / 515.17 2 2
2 12 1285.40 2 15.05 2252 68 0.23 / 515.23 2 2
3 7 2003.28 31 14.68 3043 1385 1.61 / 516.62 2 2
4 13 1519.08 27 14.66 2392 947 2.56 / 517.57 2 2
5 13 597.60 27 14.80 1185 474 3.03 / 518.04 2 2
6 13 107.40 27 14.91 530 213 3.24 / 518.25 2 2
7 8 0.12 165 14.91 344 846 4.09 / 519.10 2 3
Average= 3.99
(KJ/cycle)

Cycle 128 GMT 9/ 7/2021 1:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 21 14.89 498 156 0.16 / 511.13 2 2
2 12 1301.76 2 15.05 2266 68 0.22 / 511.20 2 2
3 7 2002.48 30 14.69 3067 1352 1.58 / 512.55 2 2
4 13 1501.28 27 14.68 2346 930 2.51 / 513.48 2 2
5 13 608.80 27 14.80 1207 482 2.99 / 513.96 2 2
6 13 114.80 27 14.91 532 214 3.20 / 514.18 2 2
7 8 0.00 165 14.92 338 832 4.03 / 515.01 2 3
Average= 3.99
(KJ/cycle)

Cycle 127 GMT 29/ 6/2021 3:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 21 14.89 495 155 0.15 / 507.10 2 2
2 12 1285.20 2 15.06 2222 67 0.22 / 507.17 2 2
3 7 2001.68 30 14.68 3066 1350 1.57 / 508.52 2 2
4 13 1499.68 27 14.67 2380 943 2.51 / 509.46 2 2
5 13 585.96 27 14.81 1182 473 2.99 / 509.94 2 2
6 13 105.60 27 14.92 521 210 3.20 / 510.15 2 2
7 8 0.04 165 14.92 337 830 4.03 / 510.98 2 5
Average= 3.99
(KJ/cycle)

Cycle 126 GMT 19/ 6/2021 5: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 21 14.89 503 157 0.16 / 503.02 2 2
2 12 1304.28 2 15.06 2263 68 0.23 / 503.09 2 2
3 7 2002.08 31 14.66 3100 1409 1.63 / 504.50 2 2
4 13 1493.92 27 14.67 2366 937 2.57 / 505.44 2 2
5 13 580.12 27 14.81 1157 463 3.03 / 505.90 2 2
6 13 109.72 27 14.92 529 213 3.25 / 506.11 2 2
7 8 0.04 165 14.92 340 837 4.08 / 506.95 2 4
Average= 3.99
(KJ/cycle)

Cycle 125 GMT 9/ 6/2021 6:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 21 14.90 487 152 0.15 / 498.99 2 2
2 12 1287.24 2 15.06 2240 67 0.22 / 499.06 2 2
3 7 2002.72 30 14.68 3050 1343 1.56 / 500.40 2 2
4 13 1497.28 27 14.67 2372 940 2.50 / 501.34 2 2
5 13 596.64 27 14.81 1179 471 2.97 / 501.81 2 2
6 13 113.28 27 14.92 538 217 3.19 / 502.03 2 2
7 8 0.12 165 14.92 339 835 4.03 / 502.86 2 4
Average= 3.99
(KJ/cycle)

Cycle 124 GMT 30/ 5/2021 7:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 21 14.89 503 157 0.16 / 494.89 2 2
2 12 1307.84 2 15.04 2260 68 0.23 / 494.95 2 2
3 7 2001.16 30 14.68 3106 1368 1.59 / 496.32 2 2
4 13 1488.68 27 14.68 2381 944 2.54 / 497.27 2 2
5 13 748.60 27 14.78 1355 541 3.08 / 497.81 2 2
6 13 102.24 27 14.93 516 208 3.29 / 498.01 2 2
7 8 0.04 165 14.92 335 825 4.11 / 498.84 2 6
Average= 3.99
(KJ/cycle)

Cycle 123 GMT 20/ 5/2021 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 21 14.89 502 157 0.16 / 490.81 2 2
2 12 1309.80 2 15.05 2284 69 0.23 / 490.88 2 2
3 7 2000.56 30 14.68 3060 1348 1.57 / 492.23 2 2
4 13 1485.12 27 14.68 2336 926 2.50 / 493.15 2 2
5 13 726.04 27 14.78 1323 528 3.03 / 493.68 2 2
6 13 92.88 27 14.93 502 202 3.23 / 493.88 2 2
7 8 0.04 165 14.92 343 844 4.07 / 494.73 2 6
Average= 3.99
(KJ/cycle)

Cycle 122 GMT 10/ 5/2021 10:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 21 14.90 492 154 0.15 / 486.77 2 2
2 12 1290.76 2 15.06 2224 67 0.22 / 486.84 2 2
3 7 2003.28 30 14.69 3085 1360 1.58 / 488.19 2 2
4 13 1498.00 27 14.68 2348 931 2.51 / 489.13 2 2
5 13 628.64 27 14.81 1220 488 3.00 / 489.61 2 2
6 13 115.36 27 14.92 532 214 3.21 / 489.83 2 2
7 8 -0.04 165 14.92 336 827 4.04 / 490.65 2 6
Average= 3.99
(KJ/cycle)

Cycle 121 GMT 30/ 4/2021 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 21 14.89 500 156 0.16 / 482.73 2 2
2 12 1293.04 2 15.06 2250 68 0.22 / 482.80 2 2
3 7 2001.28 30 14.69 3062 1349 1.57 / 484.15 2 2
4 13 1502.20 27 14.69 2356 934 2.51 / 485.08 2 2
5 13 629.16 27 14.81 1220 488 3.00 / 485.57 2 2
6 13 109.64 27 14.92 530 214 3.21 / 485.78 2 2
7 8 0.12 165 14.92 337 830 4.04 / 486.61 2 6
Average= 3.99
(KJ/cycle)

Cycle 120 GMT 20/ 4/2021 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 21 14.89 511 160 0.16 / 478.58 2 2
2 12 1307.68 2 15.05 2273 68 0.23 / 478.65 2 2
3 7 2001.96 33 14.66 3067 1484 1.71 / 480.13 2 2
4 13 1481.92 27 14.67 2353 932 2.64 / 481.06 2 2
5 13 568.00 27 14.82 1142 457 3.10 / 481.52 2 2
6 13 96.36 27 14.93 514 207 3.31 / 481.73 2 2
7 8 0.00 165 14.92 344 847 4.15 / 482.58 2 6
Average= 3.99
(KJ/cycle)

Cycle 119 GMT 10/ 4/2021 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 21 14.91 495 155 0.15 / 474.49 2 2
2 12 1313.24 2 15.05 2258 68 0.22 / 474.56 2 2
3 7 2005.48 33 14.66 3052 1476 1.70 / 476.04 2 2
4 13 1327.48 27 14.70 2130 845 2.54 / 476.88 2 2
5 13 601.88 27 14.81 1199 479 3.02 / 477.36 2 2
6 13 103.52 27 14.92 520 209 3.23 / 477.57 2 2
7 8 0.04 165 14.92 345 849 4.08 / 478.42 2 5
Average= 3.99
(KJ/cycle)

Cycle 118 GMT 31/ 3/2021 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 21 14.89 512 160 0.16 / 470.43 2 2
2 12 1297.16 1 15.08 2298 35 0.19 / 470.46 2 2
3 7 2004.48 33 14.67 3066 1484 1.68 / 471.94 2 2
4 13 1469.80 26 14.68 2345 895 2.57 / 472.84 2 2
5 13 578.80 26 14.82 1163 448 3.02 / 473.29 2 2
6 13 103.44 26 14.94 522 203 3.22 / 473.49 2 2
7 8 0.08 165 14.93 344 847 4.07 / 474.34 2 5
Average= 3.99
(KJ/cycle)

Cycle 117 GMT 21/ 3/2021 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 21 14.89 510 159 0.16 / 466.24 2 2
2 12 1324.80 1 15.08 2344 35 0.19 / 466.28 2 2
3 7 2002.52 33 14.67 3054 1478 1.67 / 467.76 2 2
4 13 1341.32 26 14.70 2181 834 2.51 / 468.59 2 2
5 13 622.48 26 14.81 1213 467 2.97 / 469.06 2 2
6 13 107.08 26 14.93 533 207 3.18 / 469.27 2 2
7 13 25.36 26 14.95 393 153 3.33 / 469.42 2 2
8 8 -0.12 165 14.91 344 846 4.18 / 470.26 2 7
Average= 3.99
(KJ/cycle)

Cycle 116 GMT 11/ 3/2021 19:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 20 14.90 500 149 0.15 / 462.10 2 2
2 12 1310.20 1 15.08 2303 35 0.18 / 462.14 2 2
3 7 2006.08 33 14.67 3046 1475 1.66 / 463.61 2 2
4 13 1490.52 22 14.70 2363 764 2.42 / 464.38 2 2
5 13 765.60 22 14.80 1391 453 2.88 / 464.83 2 2
6 13 131.20 22 14.93 572 188 3.06 / 465.02 2 2
7 13 80.44 22 14.94 488 160 3.22 / 465.18 2 2
8 8 0.04 175 14.92 347 906 4.13 / 466.09 2 4
Average= 3.98
(KJ/cycle)

Cycle 115 GMT 1/ 3/2021 21:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 20 14.89 497 148 0.15 / 457.99 2 2
2 12 1306.20 1 15.08 2310 35 0.18 / 458.03 2 2
3 7 2005.80 33 14.68 3043 1474 1.66 / 459.50 2 2
4 13 1480.56 22 14.70 2364 765 2.42 / 460.26 2 2
5 13 772.00 22 14.80 1406 458 2.88 / 460.72 2 2
6 13 122.72 22 14.94 555 182 3.06 / 460.90 2 2
7 13 83.68 22 14.94 488 160 3.22 / 461.06 2 2
8 8 0.20 175 14.93 341 891 4.11 / 461.96 2 6
Average= 3.98
(KJ/cycle)

Cycle 114 GMT 19/ 2/2021 23:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 21 14.91 498 156 0.16 / 453.87 2 2
2 12 1311.16 1 15.08 2346 35 0.19 / 453.91 2 2
3 7 2004.56 34 14.66 3068 1529 1.72 / 455.44 2 2
4 13 1343.44 22 14.71 2154 697 2.42 / 456.13 2 2
5 13 807.08 22 14.78 1452 472 2.89 / 456.61 2 2
6 13 121.60 22 14.93 555 182 3.07 / 456.79 2 2
7 13 77.68 22 14.94 485 159 3.23 / 456.95 2 2
8 8 0.00 175 14.92 343 896 4.13 / 457.84 2 8
Average= 3.98
(KJ/cycle)

Cycle 113 GMT 10/ 2/2021 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 21 14.90 498 156 0.16 / 449.78 2 2
2 12 1294.40 1 15.08 2287 34 0.19 / 449.81 2 2
3 7 2003.00 33 14.68 3030 1468 1.66 / 451.28 2 2
4 13 1480.36 22 14.70 2355 762 2.42 / 452.04 2 2
5 13 746.12 22 14.80 1375 448 2.87 / 452.49 2 2
6 13 114.40 22 14.95 543 179 3.05 / 452.67 2 2
7 13 79.52 22 14.95 483 159 3.20 / 452.83 2 2
8 8 0.04 175 14.93 340 888 4.09 / 453.72 2 6
Average= 3.98
(KJ/cycle)

Cycle 112 GMT 31/ 1/2021 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 21 14.91 497 156 0.16 / 445.79 2 2
2 12 1295.76 1 15.09 2287 35 0.19 / 445.83 2 2
3 7 2006.76 33 14.68 3035 1470 1.66 / 447.30 2 2
4 13 1348.72 22 14.73 2126 689 2.35 / 447.99 2 2
5 13 695.28 22 14.81 1303 425 2.77 / 448.41 2 2
6 13 109.32 22 14.94 533 175 2.95 / 448.59 2 2
7 13 79.52 22 14.94 474 156 3.10 / 448.74 2 2
8 8 0.04 175 14.93 337 880 3.99 / 449.62 2 5
Average= 3.98
(KJ/cycle)

Cycle 111 GMT 21/ 1/2021 4: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 21 14.90 500 156 0.16 / 441.68 2 2
2 12 1291.32 1 15.09 2268 34 0.19 / 441.72 2 2
3 7 2003.32 33 14.67 3045 1474 1.66 / 443.19 2 2
4 13 1489.28 22 14.70 2351 760 2.43 / 443.95 2 2
5 13 770.56 22 14.80 1399 456 2.88 / 444.41 2 2
6 13 133.52 22 14.94 563 185 3.07 / 444.59 2 2
7 13 82.52 22 14.95 480 158 3.22 / 444.75 2 2
8 8 0.00 175 14.93 339 886 4.11 / 445.64 2 2
Average= 3.98
(KJ/cycle)

Cycle 110 GMT 11/ 1/2021 5:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 21 14.90 500 156 0.16 / 437.58 2 2
2 12 1280.88 1 15.09 2258 34 0.19 / 437.61 2 2
3 7 2002.52 33 14.68 3051 1478 1.67 / 439.09 2 2
4 13 1478.84 22 14.70 2336 755 2.42 / 439.84 2 2
5 13 752.08 22 14.81 1369 446 2.87 / 440.29 2 2
6 13 110.96 22 14.95 540 178 3.05 / 440.47 2 2
7 13 71.00 22 14.95 475 156 3.20 / 440.62 2 2
8 8 0.04 175 14.93 346 904 4.11 / 441.53 2 10
Average= 3.98
(KJ/cycle)

Cycle 109 GMT 1/ 1/2021 7:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 21 14.91 500 157 0.16 / 433.51 2 2
2 12 1319.60 1 15.08 2317 35 0.19 / 433.54 2 2
3 7 2005.32 33 14.69 3033 1470 1.66 / 435.01 2 2
4 13 1487.24 22 14.71 2360 764 2.43 / 435.78 2 2
5 13 627.24 22 14.84 1232 402 2.83 / 436.18 2 2
6 13 129.88 22 14.94 562 185 3.01 / 436.36 2 2
7 13 73.16 22 14.95 477 157 3.17 / 436.52 2 2
8 8 -0.04 175 14.93 344 899 4.07 / 437.42 2 4
Average= 3.98
(KJ/cycle)

Cycle 108 GMT 22/12/2020 8:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 21 14.91 502 157 0.16 / 429.48 2 2
2 12 1301.44 1 15.08 2326 35 0.19 / 429.52 2 2
3 7 2002.24 33 14.68 3051 1478 1.67 / 431.00 2 2
4 13 1349.60 22 14.72 2205 714 2.38 / 431.71 2 2
5 13 650.92 22 14.83 1262 412 2.80 / 432.12 2 2
6 13 97.80 22 14.95 522 172 2.97 / 432.29 2 2
7 13 68.56 22 14.95 470 155 3.12 / 432.45 2 2
8 8 -0.04 175 14.93 346 904 4.03 / 433.35 2 5
Average= 3.98
(KJ/cycle)

Cycle 107 GMT 12/12/2020 10:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 21 14.92 504 158 0.16 / 425.40 2 2
2 3 1021.92 1 15.07 1911 29 0.19 / 425.43 2 2
3 12 1295.56 1 15.10 2296 35 0.22 / 425.47 2 2
4 7 2002.24 33 14.68 3050 1478 1.70 / 426.94 2 2
5 13 1466.72 22 14.70 2344 758 2.46 / 427.70 2 2
6 13 748.24 22 14.81 1368 446 2.90 / 428.15 2 2
7 13 116.16 22 14.95 545 179 3.08 / 428.33 2 2
8 13 66.92 22 14.96 465 153 3.23 / 428.48 2 2
9 8 -0.04 165 14.94 343 846 4.08 / 429.32 2 6
Average= 3.98
(KJ/cycle)

Cycle 106 GMT 2/12/2020 12:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 21 14.92 510 160 0.16 / 421.41 2 2
2 12 1308.68 1 15.08 2319 35 0.19 / 421.44 2 2
3 7 2003.96 31 14.69 3036 1383 1.58 / 422.83 2 2
4 13 1514.16 22 14.70 2386 772 2.35 / 423.60 2 2
5 13 810.36 22 14.80 1447 471 2.82 / 424.07 2 2
6 13 159.48 22 14.94 600 197 3.02 / 424.27 2 2
7 13 106.40 22 14.95 511 168 3.19 / 424.43 2 2
8 8 0.16 165 14.94 329 811 4.00 / 425.24 2 4
Average= 3.97
(KJ/cycle)

Cycle 105 GMT 22/11/2020 13:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 21 14.90 502 157 0.16 / 417.22 2 2
2 12 1309.32 1 15.08 2300 35 0.19 / 417.25 2 2
3 7 2001.28 31 14.70 3035 1383 1.57 / 418.63 2 2
4 13 1669.16 22 14.68 2602 840 2.42 / 419.47 2 2
5 13 765.60 22 14.82 1379 450 2.86 / 419.92 2 2
6 13 151.64 22 14.95 594 195 3.06 / 420.12 2 2
7 13 89.44 22 14.96 493 162 3.22 / 420.28 2 2
8 13 50.88 22 14.96 427 141 3.36 / 420.42 2 2
9 8 0.08 165 14.94 335 826 4.19 / 421.25 2 7
Average= 3.97
(KJ/cycle)

Cycle 104 GMT 12/11/2020 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 20 14.92 498 149 0.15 / 413.11 2 2
2 12 1325.12 1 15.08 2338 35 0.18 / 413.15 2 2
3 7 2002.32 31 14.70 3062 1395 1.58 / 414.55 2 2
4 13 1490.64 22 14.71 2341 758 2.34 / 415.30 2 2
5 13 782.04 22 14.81 1401 456 2.79 / 415.76 2 2
6 13 134.96 22 14.95 566 186 2.98 / 415.95 2 2
7 13 83.64 22 14.96 484 159 3.14 / 416.10 2 2
8 13 22.00 22 14.97 378 124 3.26 / 416.23 2 2
9 8 -0.08 165 14.93 337 830 4.09 / 417.06 2 7
Average= 3.97
(KJ/cycle)

Cycle 103 GMT 2/11/2020 16:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 20 14.91 490 146 0.15 / 409.15 2 2
2 12 1301.36 1 15.08 2297 35 0.18 / 409.18 2 2
3 7 2004.04 31 14.69 3062 1394 1.58 / 410.58 2 2
4 13 1482.88 22 14.72 2361 765 2.34 / 411.34 2 2
5 13 771.24 22 14.81 1391 453 2.79 / 411.79 2 2
6 13 130.52 22 14.95 559 184 2.98 / 411.98 2 2
7 13 87.20 22 14.96 490 161 3.14 / 412.14 2 2
8 8 0.12 165 14.95 335 826 3.96 / 412.97 2 3
Average= 3.97
(KJ/cycle)

Cycle 102 GMT 23/10/2020 18:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 21 14.91 501 157 0.16 / 404.97 2 2
2 12 1309.16 1 15.09 2303 35 0.19 / 405.01 2 2
3 7 2003.24 31 14.70 3064 1396 1.59 / 406.41 2 2
4 13 1500.12 22 14.72 2376 769 2.36 / 407.17 2 2
5 13 947.60 22 14.77 1624 528 2.89 / 407.70 2 2
6 13 127.32 22 14.96 553 182 3.07 / 407.88 2 2
7 13 79.88 22 14.96 479 158 3.22 / 408.04 2 2
8 13 21.16 22 14.97 375 124 3.35 / 408.17 2 2
9 8 -0.04 165 14.94 339 836 4.18 / 409.00 2 5
Average= 3.97
(KJ/cycle)

Cycle 101 GMT 13/10/2020 20: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 21 14.92 491 154 0.15 / 400.88 2 2
2 12 1321.32 1 15.09 2331 35 0.19 / 400.92 2 2
3 7 2006.72 31 14.71 3039 1386 1.57 / 402.31 2 2
4 13 1369.40 22 14.74 2173 705 2.28 / 403.01 2 2
5 13 849.88 22 14.79 1493 486 2.77 / 403.50 2 2
6 13 152.44 22 14.95 585 192 2.96 / 403.69 2 2
7 13 85.44 22 14.95 490 161 3.12 / 403.85 2 2
8 13 46.24 22 14.96 419 138 3.26 / 403.99 2 2
9 8 -0.12 165 14.93 337 830 4.09 / 404.82 2 7
Average= 3.97
(KJ/cycle)

Cycle 100 GMT 3/10/2020 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 20 14.93 492 147 0.15 / 396.68 2 2
2 12 1293.44 1 15.10 2280 34 0.18 / 396.71 2 2
3 7 2006.32 31 14.70 3047 1389 1.57 / 398.10 2 2
4 13 1512.88 22 14.71 2377 769 2.34 / 398.87 2 2
5 13 965.20 22 14.77 1651 536 2.88 / 399.41 2 2
6 13 206.92 22 14.93 667 219 3.09 / 399.63 2 2
7 13 78.72 22 14.97 472 155 3.25 / 399.78 2 2
8 13 20.76 22 14.98 370 122 3.37 / 399.90 2 2
9 8 0.04 165 14.94 335 826 4.20 / 400.73 2 7
Average= 3.97
(KJ/cycle)

Cycle 99 GMT 23/ 9/2020 23:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 20 14.92 491 147 0.15 / 392.70 2 2
2 12 1311.44 1 15.09 2312 35 0.18 / 392.74 2 2
3 7 2001.08 31 14.71 3052 1392 1.57 / 394.13 2 2
4 13 1508.20 22 14.71 2375 769 2.34 / 394.90 2 2
5 13 810.32 22 14.81 1448 472 2.81 / 395.37 2 2
6 13 137.68 22 14.96 567 187 3.00 / 395.56 2 2
7 13 75.84 22 14.97 473 156 3.16 / 395.71 2 2
8 8 0.00 165 14.95 333 821 3.98 / 396.53 2 3
Average= 3.97
(KJ/cycle)

Cycle 98 GMT 14/ 9/2020 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 20 14.94 491 147 0.15 / 388.69 2 2
2 12 1310.08 1 15.08 2310 35 0.18 / 388.72 2 2
3 7 2003.88 32 14.69 3075 1445 1.63 / 390.17 2 2
4 13 1483.60 22 14.70 2387 772 2.40 / 390.94 2 2
5 13 761.80 22 14.82 1386 452 2.85 / 391.39 2 2
6 13 113.04 22 14.97 534 176 3.03 / 391.57 2 2
7 13 68.84 22 14.97 461 152 3.18 / 391.72 2 2
8 8 0.12 165 14.95 338 834 4.01 / 392.56 2 6
Average= 3.97
(KJ/cycle)

Cycle 97 GMT 4/ 9/2020 2:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 20 14.93 496 148 0.15 / 384.92 2 2
2 12 1180.20 1 15.13 2119 32 0.18 / 384.96 2 2
3 7 1896.64 30 14.74 2889 1278 1.46 / 386.23 2 2
4 13 1401.84 22 14.74 2268 735 2.19 / 386.97 2 2
5 13 688.08 22 14.85 1288 421 2.61 / 387.39 2 2
6 13 103.00 22 14.98 520 171 2.79 / 387.56 2 2
7 13 64.92 22 14.98 453 149 2.93 / 387.71 2 2
8 8 0.00 165 14.96 337 832 3.77 / 388.54 2 4
Average= 3.96
(KJ/cycle)

Cycle 96 GMT 25/ 8/2020 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 20 14.92 496 148 0.15 / 381.21 2 2
2 12 1171.04 1 15.12 2109 32 0.18 / 381.25 2 2
3 7 1888.92 30 14.76 2855 1264 1.44 / 382.51 2 2
4 13 1363.68 22 14.77 2182 709 2.15 / 383.22 2 2
5 13 657.44 22 14.86 1251 409 2.56 / 383.63 2 2
6 13 98.48 22 14.98 514 169 2.73 / 383.80 2 2
7 13 62.08 22 14.98 448 148 2.88 / 383.94 2 2
8 8 0.08 165 14.96 337 832 3.71 / 384.78 2 6
Average= 3.97
(KJ/cycle)

Cycle 95 GMT 15/ 8/2020 1:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 20 14.93 492 147 0.15 / 377.24 2 2
2 12 1315.32 1 15.09 2316 35 0.18 / 377.28 2 2
3 7 2019.76 30 14.69 3085 1360 1.54 / 378.63 2 2
4 13 1403.88 22 14.73 2228 722 2.26 / 379.36 2 2
5 13 887.08 22 14.78 1557 506 2.77 / 379.86 2 2
6 13 158.60 22 14.94 603 198 2.97 / 380.06 2 2
7 13 83.96 22 14.96 491 162 3.13 / 380.22 2 2
8 8 0.08 165 14.94 342 843 3.97 / 381.07 2 5
Average= 3.97
(KJ/cycle)

Cycle 94 GMT 5/ 8/2020 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 20 14.93 498 149 0.15 / 373.27 2 2
2 12 1322.32 1 15.10 2362 36 0.18 / 373.31 2 2
3 7 2001.40 30 14.71 3073 1356 1.54 / 374.66 2 2
4 13 1499.24 22 14.72 2389 774 2.31 / 375.43 2 2
5 13 812.88 22 14.81 1446 471 2.79 / 375.91 2 2
6 13 139.72 22 14.96 576 190 2.97 / 376.10 2 2
7 13 91.76 22 14.97 503 166 3.14 / 376.26 2 2
8 8 -0.04 165 14.96 337 832 3.97 / 377.09 2 3
Average= 3.97
(KJ/cycle)

Cycle 93 GMT 26/ 7/2020 4:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 20 14.94 498 149 0.15 / 369.34 2 2
2 12 1312.28 1 15.09 2315 35 0.18 / 369.38 2 2
3 7 2003.24 30 14.72 3037 1341 1.52 / 370.72 2 2
4 13 1494.40 22 14.72 2354 762 2.29 / 371.48 2 2
5 13 799.84 22 14.82 1421 463 2.75 / 371.94 2 2
6 13 141.44 22 14.96 577 190 2.94 / 372.13 2 2
7 13 87.64 22 14.97 489 161 3.10 / 372.29 2 2
8 8 0.04 165 14.96 335 827 3.93 / 373.12 2 6
Average= 3.97
(KJ/cycle)

Cycle 92 GMT 16/ 7/2020 6: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 20 14.94 496 148 0.15 / 365.36 2 2
2 7 2004.60 30 14.72 3040 1342 1.49 / 366.70 2 2
3 13 1518.44 22 14.72 2400 777 2.27 / 367.48 2 2
4 13 827.76 22 14.81 1474 480 2.75 / 367.96 2 2
5 13 292.32 22 14.91 784 257 3.01 / 368.22 2 2
6 13 93.52 22 14.97 492 162 3.17 / 368.38 2 2
7 8 0.08 165 14.96 330 815 3.98 / 369.19 2 5
Average= 3.97
(KJ/cycle)

Cycle 91 GMT 6/ 7/2020 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 20 14.93 498 149 0.15 / 361.31 2 2
2 7 2007.60 30 14.70 3078 1357 1.51 / 362.67 2 2
3 13 1673.92 22 14.69 2631 850 2.36 / 363.52 2 2
4 13 793.24 22 14.82 1426 465 2.82 / 363.99 2 2
5 13 264.56 22 14.93 751 247 3.07 / 364.23 2 2
6 13 98.48 22 14.97 500 165 3.23 / 364.40 2 2
7 8 0.12 165 14.97 329 813 4.05 / 365.21 2 4
Average= 3.97
(KJ/cycle)

Cycle 90 GMT 26/ 6/2020 10: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 20 14.93 501 150 0.15 / 357.16 2 2
2 7 2009.48 31 14.72 3079 1405 1.55 / 358.57 2 2
3 13 1674.44 20 14.70 2626 772 2.33 / 359.34 2 2
4 13 961.84 20 14.79 1655 490 2.82 / 359.83 2 2
5 13 257.52 20 14.94 741 221 3.04 / 360.05 2 2
6 13 100.16 20 14.97 510 153 3.19 / 360.21 2 2
7 13 57.92 20 14.99 436 131 3.32 / 360.34 2 2
8 8 0.12 165 14.96 336 829 4.15 / 361.17 2 7
Average= 3.97
(KJ/cycle)

Cycle 89 GMT 16/ 6/2020 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 20 14.93 509 152 0.15 / 353.09 2 2
2 7 2015.28 30 14.72 3077 1359 1.51 / 354.45 2 2
3 13 1546.72 20 14.73 2455 723 2.23 / 355.17 2 2
4 13 877.28 20 14.80 1549 459 2.69 / 355.63 2 2
5 13 359.32 20 14.91 873 260 2.95 / 355.89 2 2
6 13 91.92 20 14.97 508 152 3.10 / 356.04 2 2
7 13 58.16 20 14.98 446 134 3.24 / 356.17 2 2
8 8 0.00 165 14.95 341 841 4.08 / 357.01 2 4
Average= 3.97
(KJ/cycle)

Cycle 88 GMT 6/ 6/2020 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 20 14.93 498 149 0.15 / 349.02 2 2
2 7 2003.32 31 14.72 3045 1389 1.54 / 350.41 2 2
3 13 1519.12 20 14.73 2419 713 2.25 / 351.12 2 2
4 13 860.56 20 14.81 1515 449 2.70 / 351.57 2 2
5 13 342.08 20 14.91 856 255 2.95 / 351.82 2 2
6 13 92.84 20 14.97 504 151 3.11 / 351.97 2 2
7 13 50.84 20 14.98 426 128 3.23 / 352.10 2 2
8 8 0.04 165 14.95 338 834 4.07 / 352.94 2 7
Average= 3.97
(KJ/cycle)

Cycle 87 GMT 27/ 5/2020 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 20 14.93 494 148 0.15 / 344.92 2 2
2 7 2006.20 30 14.73 3059 1352 1.50 / 346.27 2 2
3 13 1541.48 20 14.73 2425 714 2.21 / 346.99 2 2
4 13 1017.64 20 14.78 1727 511 2.72 / 347.50 2 2
5 13 319.96 20 14.92 832 248 2.97 / 347.75 2 2
6 13 105.88 20 14.98 522 156 3.13 / 347.90 2 2
7 13 59.80 20 14.98 439 132 3.26 / 348.03 2 2
8 8 0.04 165 14.96 338 834 4.09 / 348.87 2 6
Average= 3.96
(KJ/cycle)

Cycle 86 GMT 17/ 5/2020 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 20 14.94 494 148 0.15 / 340.85 2 2
2 7 2007.76 30 14.73 3079 1361 1.51 / 342.21 2 2
3 13 1534.60 20 14.73 2462 725 2.23 / 342.94 2 2
4 13 880.00 20 14.81 1541 456 2.69 / 343.39 2 2
5 13 362.20 20 14.91 884 264 2.95 / 343.66 2 2
6 13 106.92 20 14.97 522 156 3.11 / 343.81 2 2
7 13 67.52 20 14.98 453 136 3.25 / 343.95 2 2
8 8 0.00 165 14.96 334 824 4.07 / 344.77 2 6
Average= 3.96
(KJ/cycle)

Cycle 85 GMT 7/ 5/2020 19: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 20 14.94 500 149 0.15 / 336.71 2 2
2 7 2007.12 31 14.73 3027 1382 1.53 / 338.10 2 2
3 13 1662.92 20 14.71 2612 768 2.30 / 338.87 2 2
4 13 950.88 20 14.80 1663 492 2.79 / 339.36 2 2
5 13 276.80 20 14.94 771 230 3.02 / 339.59 2 2
6 13 102.52 20 14.98 516 155 3.18 / 339.74 2 2
7 13 58.28 20 14.99 445 133 3.31 / 339.88 2 2
8 8 0.12 165 14.97 335 827 4.14 / 340.70 2 4
Average= 3.96
(KJ/cycle)

Cycle 84 GMT 27/ 4/2020 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 20 14.95 496 148 0.15 / 332.63 2 2
2 7 2003.28 30 14.75 3021 1337 1.49 / 333.97 2 2
3 13 1532.96 20 14.73 2429 716 2.20 / 334.68 2 2
4 13 1015.76 20 14.79 1724 510 2.71 / 335.19 2 2
5 13 302.28 20 14.93 803 240 2.95 / 335.43 2 2
6 13 105.64 20 14.98 523 157 3.11 / 335.59 2 2
7 13 64.12 20 14.98 449 135 3.24 / 335.72 2 2
8 8 -0.08 165 14.96 341 842 4.08 / 336.57 2 4
Average= 3.96
(KJ/cycle)

Cycle 83 GMT 17/ 4/2020 22:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 20 14.94 496 148 0.15 / 328.59 2 2
2 7 2010.00 30 14.72 3049 1346 1.49 / 329.93 2 2
3 13 1518.12 20 14.74 2404 709 2.20 / 330.64 2 2
4 13 990.92 20 14.79 1686 499 2.70 / 331.14 2 2
5 13 260.44 20 14.95 749 224 2.93 / 331.36 2 2
6 13 107.56 20 14.99 519 156 3.08 / 331.52 2 2
7 13 64.60 20 14.99 449 135 3.22 / 331.65 2 2
8 8 0.12 165 14.97 335 827 4.04 / 332.48 2 7
Average= 3.96
(KJ/cycle)

Cycle 82 GMT 8/ 4/2020 0:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 20 14.95 500 149 0.15 / 324.57 2 2
2 7 2002.40 30 14.72 3061 1352 1.50 / 325.92 2 2
3 13 1499.08 20 14.74 2372 699 2.20 / 326.62 2 2
4 13 958.00 20 14.81 1622 480 2.68 / 327.10 2 2
5 13 266.04 20 14.95 752 225 2.91 / 327.32 2 2
6 13 93.36 20 14.99 501 150 3.06 / 327.47 2 2
7 13 55.00 20 15.00 437 131 3.19 / 327.60 2 2
8 8 0.08 165 14.97 338 835 4.02 / 328.44 2 4
Average= 3.96
(KJ/cycle)

Cycle 81 GMT 29/ 3/2020 2:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 20 14.94 505 151 0.15 / 320.49 2 2
2 7 2005.40 31 14.73 3048 1392 1.54 / 321.88 2 2
3 13 1689.88 20 14.71 2634 775 2.32 / 322.66 2 2
4 13 847.32 20 14.83 1497 444 2.76 / 323.10 2 2
5 13 182.36 20 14.97 634 190 2.95 / 323.29 2 2
6 13 103.92 20 14.99 521 156 3.11 / 323.45 2 2
7 13 59.40 20 15.00 445 133 3.24 / 323.58 2 2
8 8 0.00 165 14.97 338 835 4.08 / 324.42 2 4
Average= 3.96
(KJ/cycle)

Cycle 80 GMT 19/ 3/2020 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 20 14.96 499 149 0.15 / 316.46 2 2
2 7 2002.12 30 14.73 3045 1346 1.49 / 317.81 2 2
3 13 1526.00 20 14.74 2428 716 2.21 / 318.53 2 2
4 13 847.20 20 14.83 1500 445 2.66 / 318.97 2 2
5 13 335.20 20 14.93 846 253 2.91 / 319.22 2 2
6 13 97.92 20 14.99 507 152 3.06 / 319.38 2 2
7 13 58.80 20 14.99 440 132 3.19 / 319.51 2 2
8 8 0.00 165 14.97 337 832 4.02 / 320.34 2 4
Average= 3.95
(KJ/cycle)

Cycle 79 GMT 9/ 3/2020 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 20 14.95 497 149 0.15 / 312.32 2 2
2 7 2007.84 30 14.74 3076 1360 1.51 / 313.68 2 2
3 13 1684.40 20 14.72 2656 782 2.29 / 314.46 2 2
4 13 977.00 20 14.81 1666 493 2.78 / 314.95 2 2
5 13 294.56 20 14.95 794 237 3.02 / 315.19 2 2
6 13 97.44 20 15.00 510 153 3.17 / 315.34 2 2
7 13 58.20 20 15.00 445 133 3.31 / 315.48 2 2
8 8 0.08 165 14.98 340 840 4.15 / 316.32 2 4
Average= 3.95
(KJ/cycle)

Cycle 78 GMT 28/ 2/2020 8:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 20 14.94 503 150 0.15 / 308.25 2 2
2 7 2004.56 30 14.74 3029 1339 1.49 / 309.59 2 2
3 13 1518.04 20 14.75 2393 706 2.20 / 310.29 2 2
4 13 1003.12 20 14.80 1720 509 2.70 / 310.80 2 2
5 13 289.20 20 14.95 789 236 2.94 / 311.04 2 2
6 13 87.88 20 15.00 501 150 3.09 / 311.19 2 2
7 13 49.80 20 15.00 431 129 3.22 / 311.32 2 2
8 8 0.16 165 14.98 343 848 4.07 / 312.17 2 3
Average= 3.95
(KJ/cycle)

Cycle 77 GMT 18/ 2/2020 10:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 20 14.95 512 153 0.15 / 304.19 2 2
2 7 2004.72 30 14.76 3041 1347 1.50 / 305.54 2 2
3 13 1529.84 20 14.75 2437 719 2.22 / 306.26 2 2
4 13 864.64 20 14.83 1526 453 2.67 / 306.71 2 2
5 13 351.20 20 14.93 860 257 2.93 / 306.97 2 2
6 13 88.04 20 15.00 499 150 3.08 / 307.12 2 2
7 13 50.84 20 15.00 432 130 3.21 / 307.25 2 2
8 8 -0.04 165 14.98 344 850 4.06 / 308.10 2 7
Average= 3.95
(KJ/cycle)

Cycle 76 GMT 8/ 2/2020 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 20 14.95 506 151 0.15 / 300.09 2 2
2 7 2005.32 31 14.75 3036 1388 1.54 / 301.48 2 2
3 13 1532.00 20 14.75 2415 712 2.25 / 302.19 2 2
4 13 865.20 20 14.83 1526 453 2.70 / 302.64 2 2
5 13 351.08 20 14.94 864 258 2.96 / 302.90 2 2
6 13 86.28 20 15.00 502 151 3.11 / 303.05 2 2
7 13 53.52 20 15.00 440 132 3.25 / 303.18 2 2
8 8 -0.04 165 14.97 347 857 4.10 / 304.04 2 7
Average= 3.95
(KJ/cycle)

Cycle 75 GMT 29/ 1/2020 13:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 20 14.96 506 151 0.15 / 296.05 2 2
2 7 2004.00 30 14.74 3044 1346 1.50 / 297.39 2 2
3 13 1517.92 20 14.74 2433 717 2.21 / 298.11 2 2
4 13 846.60 20 14.84 1499 445 2.66 / 298.56 2 2
5 13 337.80 20 14.94 853 255 2.91 / 298.81 2 2
6 13 91.88 20 15.00 504 151 3.07 / 298.96 2 2
7 13 56.08 20 15.00 441 132 3.20 / 299.09 2 2
8 8 0.00 165 14.98 342 845 4.04 / 299.94 2 5
Average= 3.95
(KJ/cycle)

Cycle 74 GMT 19/ 1/2020 15:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 20 14.97 501 150 0.15 / 292.04 2 2
2 7 2005.88 30 14.75 3051 1350 1.50 / 293.39 2 2
3 13 1507.64 20 14.76 2382 703 2.20 / 294.09 2 2
4 13 843.00 20 14.85 1486 441 2.64 / 294.54 2 2
5 13 309.36 20 14.95 813 243 2.89 / 294.78 2 2
6 13 99.32 20 15.01 508 153 3.04 / 294.93 2 2
7 13 61.00 20 15.01 444 133 3.17 / 295.06 2 2
8 8 0.04 165 14.99 336 831 4.00 / 295.90 2 7
Average= 3.95
(KJ/cycle)

Cycle 73 GMT 9/ 1/2020 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 20 14.98 499 150 0.15 / 288.02 2 2
2 7 2008.44 31 14.75 3041 1390 1.54 / 289.41 2 2
3 13 1516.64 20 14.74 2437 718 2.26 / 290.13 2 2
4 13 859.92 20 14.84 1517 450 2.71 / 290.58 2 2
5 13 203.12 20 14.99 661 198 2.91 / 290.77 2 2
6 13 112.32 20 15.01 529 159 3.07 / 290.93 2 2
7 13 62.92 20 15.01 446 134 3.20 / 291.07 2 2
8 8 0.12 165 14.99 333 824 4.02 / 291.89 2 8
Average= 3.94
(KJ/cycle)

Cycle 72 GMT 30/12/2019 19:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 20 14.98 503 151 0.15 / 283.96 2 2
2 7 2003.36 30 14.76 3065 1357 1.51 / 285.32 2 2
3 13 1493.04 20 14.77 2367 699 2.21 / 286.01 2 2
4 13 981.20 20 14.82 1718 509 2.72 / 286.52 2 2
5 13 278.64 20 14.98 775 232 2.95 / 286.76 2 2
6 13 91.84 20 15.02 497 149 3.10 / 286.91 2 2
7 13 55.96 20 15.03 436 131 3.23 / 287.04 2 2
8 8 0.08 165 15.00 336 832 4.06 / 287.87 2 4
Average= 3.94
(KJ/cycle)

Cycle 71 GMT 20/12/2019 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 20 14.98 505 151 0.15 / 279.94 2 2
2 7 2004.00 30 14.75 3057 1353 1.50 / 281.29 2 2
3 13 1513.60 20 14.77 2390 706 2.21 / 282.00 2 2
4 13 832.40 20 14.86 1477 439 2.65 / 282.44 2 2
5 13 307.28 20 14.96 809 242 2.89 / 282.68 2 2
6 13 93.64 20 15.02 507 152 3.04 / 282.83 2 2
7 13 54.72 20 15.02 443 133 3.18 / 282.97 2 2
8 8 -0.04 165 15.00 340 841 4.02 / 283.81 2 4
Average= 3.94
(KJ/cycle)

Cycle 70 GMT 10/12/2019 23: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 20 14.99 506 152 0.15 / 275.87 2 2
2 7 2004.60 31 14.76 3042 1392 1.54 / 277.26 2 2
3 13 1516.96 20 14.77 2399 709 2.25 / 277.97 2 2
4 13 849.76 20 14.86 1510 449 2.70 / 278.42 2 2
5 13 321.00 20 14.97 821 246 2.95 / 278.67 2 2
6 13 96.92 20 15.02 504 151 3.10 / 278.82 2 2
7 13 60.20 20 15.03 445 134 3.23 / 278.95 2 2
8 8 0.08 165 15.00 338 837 4.07 / 279.79 2 5
Average= 3.94
(KJ/cycle)

Cycle 69 GMT 1/12/2019 0:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 20 14.99 498 149 0.15 / 271.78 2 2
2 7 2006.40 30 14.75 3054 1351 1.50 / 273.14 2 2
3 13 1528.28 20 14.77 2420 715 2.22 / 273.85 2 2
4 13 1008.68 20 14.82 1736 515 2.73 / 274.37 2 2
5 13 303.20 20 14.98 801 240 2.97 / 274.61 2 2
6 13 90.20 20 15.03 492 148 3.12 / 274.75 2 2
7 13 53.20 20 15.03 436 131 3.25 / 274.88 2 2
8 8 0.08 165 15.01 338 837 4.09 / 275.72 2 3
Average= 3.94
(KJ/cycle)

Cycle 68 GMT 21/11/2019 2:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 20 15.00 506 152 0.15 / 267.66 2 2
2 7 2003.44 30 14.77 3061 1356 1.51 / 269.01 2 2
3 13 1671.24 20 14.75 2608 769 2.28 / 269.78 2 2
4 13 963.80 20 14.84 1680 499 2.78 / 270.28 2 2
5 13 271.92 20 14.99 761 228 3.00 / 270.51 2 2
6 13 92.60 20 15.04 501 151 3.15 / 270.66 2 2
7 13 55.84 20 15.04 441 133 3.29 / 270.79 2 2
8 8 0.04 165 15.02 340 843 4.13 / 271.63 2 5
Average= 3.94
(KJ/cycle)

Cycle 67 GMT 11/11/2019 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 20 15.02 500 150 0.15 / 263.61 2 2
2 7 2002.92 31 14.76 3059 1400 1.55 / 265.01 2 2
3 13 1525.84 20 14.76 2449 723 2.27 / 265.74 2 2
4 13 849.88 20 14.87 1494 444 2.72 / 266.18 2 2
5 13 184.52 20 15.03 643 193 2.91 / 266.37 2 2
6 13 97.92 20 15.04 518 156 3.07 / 266.53 2 2
7 13 35.80 20 15.06 408 123 3.19 / 266.65 2 2
8 8 0.00 165 15.03 344 853 4.04 / 267.50 2 4
Average= 3.93
(KJ/cycle)

Cycle 66 GMT 1/11/2019 6:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 20 15.02 488 147 0.15 / 259.47 2 2
2 7 2004.36 31 14.77 3059 1401 1.55 / 260.87 2 2
3 13 1674.44 20 14.75 2601 767 2.31 / 261.64 2 2
4 13 957.92 20 14.85 1662 494 2.81 / 262.14 2 2
5 13 239.72 20 15.02 714 214 3.02 / 262.35 2 2
6 13 91.76 20 15.06 498 150 3.17 / 262.50 2 2
7 13 56.28 20 15.06 435 131 3.30 / 262.63 2 2
8 8 0.00 165 15.04 335 831 4.13 / 263.46 2 5
Average= 3.93
(KJ/cycle)

Cycle 65 GMT 22/10/2019 8: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 20 15.02 503 151 0.15 / 255.38 2 2
2 7 2007.80 30 14.76 3059 1355 1.51 / 256.73 2 2
3 13 1683.04 20 14.75 2639 779 2.28 / 257.51 2 2
4 13 967.60 20 14.85 1687 501 2.79 / 258.01 2 2
5 13 155.12 20 15.05 602 181 2.97 / 258.19 2 2
6 13 102.28 20 15.05 520 157 3.12 / 258.35 2 2
7 13 33.28 20 15.08 404 122 3.24 / 258.47 2 2
8 8 0.16 165 15.04 345 856 4.10 / 259.33 2 6
Average= 3.93
(KJ/cycle)

Cycle 64 GMT 12/10/2019 9:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 20 15.02 502 151 0.15 / 251.29 2 2
2 7 2002.36 31 14.77 3038 1391 1.54 / 252.68 2 2
3 13 1505.44 20 14.79 2389 707 2.25 / 253.39 2 2
4 13 961.04 20 14.86 1651 491 2.74 / 253.88 2 2
5 13 240.76 20 15.02 720 216 2.96 / 254.09 2 2
6 13 106.56 20 15.06 519 156 3.11 / 254.25 2 2
7 13 59.00 20 15.07 442 133 3.24 / 254.38 2 2
8 8 0.12 165 15.05 340 844 4.09 / 255.23 2 5
Average= 3.93
(KJ/cycle)

Cycle 63 GMT 2/10/2019 11:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 20 15.03 490 147 0.15 / 247.24 2 2
2 7 2003.80 30 14.78 3038 1347 1.49 / 248.58 2 2
3 13 1519.68 20 14.79 2429 718 2.21 / 249.30 2 2
4 13 842.36 20 14.89 1487 443 2.66 / 249.75 2 2
5 13 344.12 20 15.00 860 258 2.91 / 250.00 2 2
6 13 101.00 20 15.07 513 155 3.07 / 250.16 2 2
7 13 61.00 20 15.07 448 135 3.20 / 250.29 2 2
8 8 0.04 165 15.05 340 844 4.05 / 251.14 2 5
Average= 3.92
(KJ/cycle)

Cycle 62 GMT 22/ 9/2019 13:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 20 15.03 504 152 0.15 / 243.16 2 2
2 7 2005.28 30 14.78 3066 1359 1.51 / 244.52 2 2
3 13 1522.16 20 14.79 2384 705 2.22 / 245.23 2 2
4 13 991.80 20 14.86 1693 503 2.72 / 245.73 2 2
5 13 299.68 20 15.02 797 239 2.96 / 245.97 2 2
6 13 111.12 20 15.07 519 156 3.12 / 246.13 2 2
7 13 63.00 20 15.08 441 133 3.25 / 246.26 2 2
8 8 0.04 165 15.06 334 830 4.08 / 247.09 2 6
Average= 3.92
(KJ/cycle)

Cycle 61 GMT 12/ 9/2019 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 20 15.04 509 153 0.15 / 239.05 2 2
2 7 2003.08 30 14.79 3055 1356 1.51 / 240.40 2 2
3 13 1665.96 20 14.77 2620 774 2.28 / 241.18 2 2
4 13 951.96 20 14.88 1626 484 2.77 / 241.66 2 2
5 13 277.20 20 15.04 767 231 3.00 / 241.89 2 2
6 13 103.08 20 15.08 518 156 3.15 / 242.05 2 2
7 13 57.84 20 15.09 440 133 3.29 / 242.18 2 2
8 8 -0.04 165 15.06 335 832 4.12 / 243.01 2 9
Average= 3.92
(KJ/cycle)

Cycle 60 GMT 2/ 9/2019 17:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 20 15.04 501 151 0.15 / 235.05 2 2
2 7 2002.12 31 14.78 3012 1380 1.53 / 236.43 2 2
3 13 1491.12 20 14.80 2339 692 2.22 / 237.12 2 2
4 13 805.44 20 14.92 1437 429 2.65 / 237.55 2 2
5 13 288.64 20 15.04 777 234 2.89 / 237.78 2 2
6 13 112.00 20 15.08 527 159 3.04 / 237.94 2 2
7 13 35.32 20 15.10 391 118 3.16 / 238.06 2 2
8 8 0.00 165 15.08 334 831 3.99 / 238.89 2 6
Average= 3.92
(KJ/cycle)

Cycle 59 GMT 23/ 8/2019 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 20 15.06 504 152 0.15 / 230.94 2 2
2 7 2002.16 30 14.78 3078 1365 1.52 / 232.31 2 2
3 13 1528.68 20 14.80 2411 714 2.23 / 233.02 2 2
4 13 1008.92 20 14.87 1707 508 2.74 / 233.53 2 2
5 13 297.28 20 15.04 787 237 2.97 / 233.76 2 2
6 13 109.88 20 15.09 519 157 3.13 / 233.92 2 2
7 13 62.64 20 15.10 444 134 3.27 / 234.05 2 2
8 8 0.08 165 15.07 340 845 4.11 / 234.90 2 5
Average= 3.91
(KJ/cycle)

Cycle 58 GMT 13/ 8/2019 21: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 20 15.05 501 151 0.15 / 226.94 2 2
2 7 2004.72 31 14.78 3057 1401 1.55 / 228.34 2 2
3 13 1508.20 20 14.81 2358 698 2.25 / 229.04 2 2
4 13 836.08 20 14.92 1476 440 2.69 / 229.48 2 2
5 13 185.92 20 15.08 639 193 2.88 / 229.67 2 2
6 13 113.44 20 15.09 531 160 3.04 / 229.83 2 2
7 13 32.00 20 15.11 398 120 3.16 / 229.95 2 2
8 8 0.16 165 15.08 337 839 4.00 / 230.79 2 4
Average= 3.91
(KJ/cycle)

Cycle 57 GMT 3/ 8/2019 22:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 20 15.06 493 148 0.15 / 222.74 2 2
2 7 2004.36 30 14.79 3043 1350 1.50 / 224.09 2 2
3 13 1668.24 20 14.78 2605 770 2.27 / 224.86 2 2
4 13 952.72 20 14.90 1659 494 2.76 / 225.36 2 2
5 13 404.64 20 15.02 935 281 3.04 / 225.64 2 2
6 13 99.08 20 15.10 519 157 3.20 / 225.79 2 2
7 13 55.88 20 15.10 442 133 3.33 / 225.93 2 2
8 8 0.04 165 15.08 345 858 4.19 / 226.79 2 5
Average= 3.91
(KJ/cycle)

Cycle 56 GMT 25/ 7/2019 1:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 20 15.07 491 148 0.15 / 218.75 2 2
2 7 2002.76 30 14.79 3034 1346 1.49 / 220.09 2 2
3 13 1510.92 20 14.81 2410 714 2.21 / 220.81 2 2
4 13 852.16 20 14.93 1485 443 2.65 / 221.25 2 2
5 13 314.92 20 15.05 817 246 2.90 / 221.49 2 2
6 13 95.44 20 15.10 501 151 3.05 / 221.65 2 2
7 13 28.40 20 15.12 385 116 3.17 / 221.76 2 2
8 8 0.04 165 15.09 334 832 4.00 / 222.59 2 7
Average= 3.91
(KJ/cycle)

Cycle 55 GMT 15/ 7/2019 3: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 20 15.08 498 150 0.15 / 214.70 2 2
2 7 2004.36 30 14.80 3072 1364 1.51 / 216.06 2 2
3 13 1542.24 20 14.80 2404 712 2.23 / 216.77 2 2
4 13 890.12 20 14.92 1550 463 2.69 / 217.23 2 2
5 13 351.32 20 15.04 854 257 2.95 / 217.49 2 2
6 13 99.44 20 15.11 510 154 3.10 / 217.64 2 2
7 13 27.68 20 15.13 391 118 3.22 / 217.76 2 2
8 8 0.04 165 15.10 335 835 4.05 / 218.60 2 4
Average= 3.90
(KJ/cycle)

Cycle 54 GMT 5/ 7/2019 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 20 15.08 496 150 0.15 / 210.59 2 2
2 7 2006.16 30 14.80 3065 1361 1.51 / 211.95 2 2
3 13 1670.88 20 14.78 2606 770 2.28 / 212.72 2 2
4 13 971.28 20 14.91 1648 491 2.77 / 213.21 2 2
5 13 273.68 20 15.07 758 228 3.00 / 213.44 2 2
6 13 109.12 20 15.12 521 158 3.16 / 213.60 2 2
7 13 33.20 20 15.14 393 119 3.28 / 213.71 2 2
8 8 -0.04 165 15.11 333 830 4.11 / 214.54 2 5
Average= 3.90
(KJ/cycle)

Cycle 53 GMT 25/ 6/2019 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 20 15.09 490 148 0.15 / 206.54 2 2
2 7 2004.36 30 14.79 3052 1354 1.50 / 207.89 2 2
3 13 1506.20 20 14.82 2354 698 2.20 / 208.59 2 2
4 13 969.28 20 14.91 1651 492 2.69 / 209.08 2 2
5 13 272.56 20 15.07 760 229 2.92 / 209.31 2 2
6 13 107.00 20 15.12 517 156 3.08 / 209.47 2 2
7 13 59.80 20 15.13 438 133 3.21 / 209.60 2 2
8 8 0.00 165 15.11 336 838 4.05 / 210.44 2 4
Average= 3.90
(KJ/cycle)

Cycle 52 GMT 15/ 6/2019 8:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 20 15.10 496 150 0.15 / 202.45 2 2
2 7 2004.24 30 14.79 3065 1360 1.51 / 203.81 2 2
3 13 1668.92 20 14.79 2612 773 2.28 / 204.58 2 2
4 13 937.80 20 14.92 1637 488 2.77 / 205.07 2 2
5 13 247.68 20 15.09 722 218 2.99 / 205.29 2 2
6 13 100.80 20 15.13 509 154 3.14 / 205.44 2 2
7 13 27.76 20 15.15 384 116 3.26 / 205.56 2 2
8 8 -0.04 165 15.12 334 833 4.09 / 206.39 2 4
Average= 3.89
(KJ/cycle)

Cycle 51 GMT 5/ 6/2019 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 20 15.10 495 149 0.15 / 198.44 2 2
2 7 2004.12 30 14.82 3047 1355 1.50 / 199.80 2 2
3 13 1685.04 20 14.80 2608 772 2.28 / 200.57 2 2
4 13 983.00 20 14.92 1679 501 2.78 / 201.07 2 2
5 13 290.24 20 15.08 782 236 3.01 / 201.31 2 2
6 13 106.88 20 15.13 521 158 3.17 / 201.46 2 2
7 8 0.04 165 15.13 334 834 4.00 / 202.30 2 4
Average= 3.89
(KJ/cycle)

Cycle 50 GMT 26/ 5/2019 11:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 20 15.09 506 153 0.15 / 194.34 2 2
2 7 2004.60 30 14.81 3058 1359 1.51 / 195.70 2 2
3 13 1531.40 20 14.83 2399 712 2.22 / 196.41 2 2
4 13 1006.32 20 14.91 1696 506 2.73 / 196.92 2 2
5 13 174.80 20 15.12 622 188 2.92 / 197.10 2 2
6 13 122.00 20 15.13 543 164 3.08 / 197.27 2 2
7 13 31.80 20 15.16 389 118 3.20 / 197.39 2 2
8 8 0.20 180 15.12 333 906 4.11 / 198.29 2 6
Average= 3.89
(KJ/cycle)

Cycle 49 GMT 16/ 5/2019 13:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 20 15.11 504 152 0.15 / 190.23 2 2
2 7 2007.64 31 14.81 3020 1387 1.54 / 191.62 2 2
3 13 1532.40 20 14.82 2429 720 2.26 / 192.34 2 2
4 13 856.08 20 14.95 1502 449 2.71 / 192.79 2 2
5 13 204.28 20 15.11 664 201 2.91 / 192.99 2 2
6 13 107.04 20 15.13 522 158 3.07 / 193.15 2 2
7 13 57.60 20 15.14 434 131 3.20 / 193.28 2 2
8 8 -0.08 180 15.12 334 909 4.11 / 194.19 2 12
Average= 3.88
(KJ/cycle)

Cycle 48 GMT 6/ 5/2019 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 20 15.12 488 148 0.15 / 186.27 2 2
2 7 2008.20 30 14.81 3062 1360 1.51 / 187.63 2 2
3 13 1492.84 20 14.85 2336 694 2.20 / 188.32 2 2
4 13 972.16 20 14.93 1648 492 2.69 / 188.81 2 2
5 13 245.52 20 15.11 717 217 2.91 / 189.03 2 2
6 13 114.64 20 15.14 526 159 3.07 / 189.19 2 2
7 8 0.08 180 15.14 327 891 3.96 / 190.08 2 4
Average= 3.88
(KJ/cycle)

Cycle 47 GMT 26/ 4/2019 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 20 15.12 486 147 0.15 / 182.24 2 2
2 7 2009.32 30 14.80 3048 1353 1.50 / 183.59 2 2
3 13 1522.96 20 14.84 2382 707 2.21 / 184.30 2 2
4 13 852.32 20 14.96 1505 450 2.66 / 184.75 2 2
5 13 494.40 20 15.03 1054 317 2.97 / 185.06 2 2
6 13 111.24 20 15.14 518 157 3.13 / 185.22 2 2
7 8 0.04 180 15.14 330 899 4.03 / 186.12 2 4
Average= 3.88
(KJ/cycle)

Cycle 46 GMT 16/ 4/2019 18:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 20 15.11 496 150 0.15 / 178.25 2 2
2 7 2006.80 31 14.81 3021 1387 1.54 / 179.64 2 2
3 13 1485.16 20 14.86 2321 690 2.23 / 180.33 2 2
4 13 951.52 20 14.94 1630 487 2.71 / 180.81 2 2
5 13 260.56 20 15.11 736 222 2.94 / 181.04 2 2
6 13 119.76 20 15.15 530 161 3.10 / 181.20 2 2
7 8 0.12 180 15.15 327 892 3.99 / 182.09 2 5
Average= 3.87
(KJ/cycle)

Cycle 45 GMT 6/ 4/2019 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 20 15.12 494 149 0.15 / 174.24 2 2
2 7 2003.20 30 14.83 3015 1341 1.49 / 175.58 2 2
3 13 1510.48 22 14.84 2367 773 2.26 / 176.35 2 2
4 13 824.52 22 14.98 1452 479 2.74 / 176.83 2 2
5 13 167.76 22 15.14 609 203 2.94 / 177.03 2 2
6 13 104.84 22 15.15 506 169 3.11 / 177.20 2 2
7 8 0.04 180 15.14 330 899 4.01 / 178.10 2 7
Average= 3.87
(KJ/cycle)

Cycle 44 GMT 27/ 3/2019 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 20 15.12 497 150 0.15 / 170.20 2 2
2 7 2002.52 30 14.83 3032 1349 1.50 / 171.55 2 2
3 13 1502.64 22 14.85 2359 771 2.27 / 172.32 2 2
4 13 814.64 22 14.99 1454 480 2.75 / 172.80 2 2
5 13 169.52 22 15.14 620 207 2.96 / 173.01 2 2
6 13 105.52 22 15.15 515 172 3.13 / 173.18 2 2
7 8 0.12 180 15.15 334 911 4.04 / 174.09 2 5
Average= 3.87
(KJ/cycle)

Cycle 43 GMT 18/ 3/2019 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 20 15.13 502 152 0.15 / 166.05 2 2
2 7 2007.60 30 14.82 3083 1371 1.52 / 167.42 2 2
3 13 1516.72 22 14.85 2379 777 2.30 / 168.20 2 2
4 13 970.76 22 14.94 1643 540 2.84 / 168.74 2 2
5 13 206.92 22 15.13 661 220 3.06 / 168.96 2 2
6 13 107.76 22 15.15 521 174 3.23 / 169.13 2 2
7 8 0.12 180 15.14 337 918 4.15 / 170.05 2 9
Average= 3.86
(KJ/cycle)

Cycle 42 GMT 8/ 3/2019 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 20 15.13 488 148 0.15 / 162.06 2 2
2 7 2002.64 30 14.82 3046 1354 1.50 / 163.41 2 2
3 13 1500.12 22 14.87 2342 766 2.27 / 164.18 2 2
4 13 814.96 22 14.99 1433 473 2.74 / 164.65 2 2
5 13 152.32 22 15.16 587 196 2.94 / 164.85 2 2
6 13 103.92 22 15.16 507 169 3.11 / 165.02 2 2
7 8 -0.04 175 15.15 332 880 3.99 / 165.90 2 4
Average= 3.86
(KJ/cycle)

Cycle 41 GMT 26/ 2/2019 4:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 20 15.13 494 149 0.15 / 158.05 2 2
2 7 2006.84 30 14.83 3066 1364 1.51 / 159.42 2 2
3 13 1511.48 22 14.86 2352 769 2.28 / 160.19 2 2
4 13 838.00 22 14.99 1459 481 2.76 / 160.67 2 2
5 13 155.76 22 15.15 589 196 2.96 / 160.86 2 2
6 13 92.76 22 15.16 497 166 3.13 / 161.03 2 2
7 8 0.00 175 15.15 333 883 4.01 / 161.91 2 5
Average= 3.86
(KJ/cycle)

Cycle 40 GMT 16/ 2/2019 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 20 15.14 488 148 0.15 / 154.05 2 2
2 7 2002.32 30 14.85 3015 1343 1.49 / 155.39 2 2
3 13 1508.20 22 14.86 2393 782 2.27 / 156.17 2 2
4 13 817.48 22 15.00 1442 476 2.75 / 156.65 2 2
5 13 147.88 22 15.16 585 195 2.94 / 156.84 2 2
6 13 88.52 22 15.17 490 164 3.11 / 157.01 2 2
7 8 0.08 175 15.16 338 897 4.00 / 157.90 2 4
Average= 3.85
(KJ/cycle)

Cycle 39 GMT 6/ 2/2019 7:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 20 15.15 493 149 0.15 / 149.92 2 2
2 7 2002.12 30 14.86 3037 1354 1.50 / 151.27 2 2
3 13 1671.68 22 14.84 2584 844 2.35 / 152.12 2 2
4 13 930.84 22 14.97 1610 530 2.88 / 152.65 2 2
5 13 197.92 22 15.15 650 217 3.09 / 152.86 2 2
6 13 89.44 22 15.18 487 163 3.26 / 153.03 2 2
7 8 0.08 175 15.17 329 873 4.13 / 153.90 2 5
Average= 3.85
(KJ/cycle)

Cycle 38 GMT 27/ 1/2019 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 20 15.14 493 149 0.15 / 145.90 2 2
2 7 2007.48 30 14.85 3047 1357 1.51 / 147.26 2 2
3 13 1512.52 22 14.88 2360 773 2.28 / 148.03 2 2
4 13 805.64 22 15.01 1447 478 2.76 / 148.51 2 2
5 13 155.72 22 15.17 601 201 2.96 / 148.71 2 2
6 13 105.80 22 15.18 517 173 3.13 / 148.88 2 2
7 8 0.16 175 15.18 333 885 4.01 / 149.77 2 5
Average= 3.84
(KJ/cycle)

Cycle 37 GMT 17/ 1/2019 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 20 15.15 477 145 0.14 / 141.90 2 2
2 7 2008.60 30 14.84 3082 1372 1.52 / 143.27 2 2
3 13 1530.04 22 14.87 2402 786 2.30 / 144.05 2 2
4 13 835.52 22 15.00 1481 489 2.79 / 144.54 2 2
5 13 148.92 22 15.17 591 197 2.99 / 144.74 2 2
6 13 80.08 22 15.18 482 161 3.15 / 144.90 2 2
7 8 0.12 165 15.17 341 854 4.00 / 145.75 2 4
Average= 3.84
(KJ/cycle)

Cycle 36 GMT 7/ 1/2019 13:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 20 15.15 489 148 0.15 / 137.88 2 2
2 7 2006.68 30 14.85 3065 1365 1.51 / 139.24 2 2
3 13 1517.88 23 14.87 2394 819 2.33 / 140.06 2 2
4 13 815.04 23 15.00 1440 497 2.83 / 140.56 2 2
5 13 142.84 23 15.17 573 200 3.03 / 140.76 2 2
6 13 62.84 23 15.19 445 155 3.18 / 140.91 2 2
7 8 0.12 165 15.17 335 839 4.02 / 141.75 2 5
Average= 3.83
(KJ/cycle)

Cycle 35 GMT 28/12/2018 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 20 15.15 494 150 0.15 / 133.83 2 2
2 7 2002.24 30 14.85 3065 1365 1.52 / 135.20 2 2
3 13 1522.32 23 14.86 2402 821 2.34 / 136.02 2 2
4 13 823.52 23 15.00 1446 499 2.83 / 136.52 2 2
5 13 143.68 23 15.17 581 203 3.04 / 136.72 2 2
6 13 65.56 23 15.19 452 158 3.20 / 136.88 2 2
7 8 -0.04 165 15.18 339 849 4.04 / 137.73 2 6
Average= 3.83
(KJ/cycle)

Cycle 34 GMT 18/12/2018 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 20 15.15 494 150 0.15 / 129.83 2 2
2 7 2006.56 30 14.85 3047 1357 1.51 / 131.19 2 2
3 13 1509.00 23 14.88 2365 809 2.32 / 132.00 2 2
4 13 800.60 23 15.02 1412 488 2.80 / 132.49 2 2
5 13 141.56 23 15.18 569 199 3.00 / 132.69 2 2
6 13 57.56 23 15.20 437 153 3.16 / 132.84 2 2
7 8 0.12 165 15.18 337 844 4.00 / 133.68 2 4
Average= 3.82
(KJ/cycle)

Cycle 33 GMT 8/12/2018 19:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 20 15.16 491 149 0.15 / 125.81 2 2
2 7 2007.80 31 14.85 3036 1398 1.55 / 127.21 2 2
3 13 1673.36 18 14.85 2599 695 2.24 / 127.90 2 2
4 13 976.44 18 14.99 1683 454 2.70 / 128.36 2 2
5 13 316.08 18 15.14 817 223 2.92 / 128.58 2 2
6 13 84.96 18 15.20 492 135 3.05 / 128.71 2 2
7 13 46.48 18 15.20 427 117 3.17 / 128.83 2 2
8 8 -0.04 165 15.18 340 852 4.02 / 129.68 2 5
Average= 3.81
(KJ/cycle)

Cycle 32 GMT 28/11/2018 20:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 20 15.16 491 149 0.15 / 121.96 2 2
2 7 2002.92 30 14.86 3034 1353 1.50 / 123.31 2 2
3 13 1368.36 18 14.93 2170 583 2.08 / 123.90 2 2
4 13 902.04 18 15.01 1558 421 2.51 / 124.32 2 2
5 13 395.60 18 15.12 917 250 2.76 / 124.57 2 2
6 13 75.96 18 15.20 471 129 2.88 / 124.70 2 2
7 13 47.92 18 15.20 426 117 3.00 / 124.81 2 2
8 8 0.04 165 15.18 339 849 3.85 / 125.66 2 4
Average= 3.81
(KJ/cycle)

Cycle 31 GMT 18/11/2018 22:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 20 15.16 505 153 0.15 / 117.99 2 2
2 7 2009.08 30 14.86 3025 1349 1.50 / 119.34 2 2
3 13 1521.04 18 14.90 2408 646 2.15 / 119.99 2 2
4 13 1007.52 18 14.99 1715 463 2.61 / 120.45 2 2
5 13 473.84 18 15.10 1021 278 2.89 / 120.73 2 2
6 13 89.00 18 15.21 491 134 3.02 / 120.86 2 2
7 13 56.36 18 15.21 438 120 3.14 / 120.98 2 2
8 8 0.08 165 15.19 332 832 3.97 / 121.81 2 5
Average= 3.81
(KJ/cycle)

Cycle 30 GMT 9/11/2018 0:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 20 15.17 488 148 0.15 / 114.10 2 2
2 7 2001.48 30 14.87 3035 1354 1.50 / 115.46 2 2
3 13 1489.32 18 14.92 2320 623 2.13 / 116.08 2 2
4 13 970.24 18 15.01 1662 449 2.57 / 116.53 2 2
5 13 303.88 18 15.16 797 217 2.79 / 116.74 2 2
6 13 87.52 18 15.21 493 135 2.93 / 116.88 2 2
7 13 56.20 18 15.21 435 119 3.05 / 117.00 2 2
8 8 -0.04 165 15.19 335 840 3.89 / 117.84 2 4
Average= 3.80
(KJ/cycle)

Cycle 29 GMT 30/10/2018 2:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 20 15.17 488 148 0.15 / 110.15 2 2
2 7 2004.04 30 14.87 3037 1355 1.50 / 111.51 2 2
3 13 1493.64 18 14.92 2352 632 2.13 / 112.14 2 2
4 13 967.08 18 15.01 1660 448 2.58 / 112.59 2 2
5 13 438.80 18 15.12 974 265 2.85 / 112.85 2 2
6 13 82.68 18 15.21 487 133 2.98 / 112.99 2 2
7 13 51.92 18 15.22 433 119 3.10 / 113.11 2 2
8 8 0.08 165 15.19 338 847 3.95 / 113.95 2 4
Average= 3.80
(KJ/cycle)

Cycle 28 GMT 20/10/2018 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 20 15.18 494 150 0.15 / 106.07 2 2
2 7 2006.96 30 14.89 3024 1351 1.50 / 107.42 2 2
3 13 1527.44 18 14.92 2375 638 2.14 / 108.06 2 2
4 13 1018.00 18 15.00 1700 459 2.60 / 108.52 2 2
5 13 478.36 18 15.12 1025 279 2.88 / 108.79 2 2
6 13 92.12 18 15.21 492 135 3.01 / 108.93 2 2
7 13 58.60 18 15.21 442 121 3.13 / 109.05 2 2
8 13 32.68 18 15.22 397 109 3.24 / 109.16 2 2
9 8 -0.04 165 15.19 338 847 4.09 / 110.01 2 9
Average= 3.79
(KJ/cycle)

Cycle 27 GMT 10/10/2018 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 20 15.18 492 149 0.15 / 102.15 2 2
2 7 2003.64 31 14.87 3059 1410 1.56 / 103.56 2 2
3 13 1355.28 18 14.96 2137 575 2.13 / 104.14 2 2
4 13 1014.04 18 15.00 1710 462 2.60 / 104.60 2 2
5 13 316.52 18 15.16 820 224 2.82 / 104.82 2 2
6 13 107.64 18 15.21 523 143 2.96 / 104.96 2 2
7 13 66.00 18 15.22 448 123 3.09 / 105.09 2 2
8 8 0.12 165 15.20 331 830 3.92 / 105.92 2 4
Average= 3.78
(KJ/cycle)

Cycle 26 GMT 30/ 9/2018 8: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 20 15.17 489 148 0.15 / 98.18 2 2
2 7 2005.20 30 14.87 3054 1362 1.51 / 99.54 2 2
3 13 1516.84 18 14.92 2372 637 2.15 / 100.18 2 2
4 13 991.68 18 15.01 1690 457 2.60 / 100.63 2 2
5 13 461.20 18 15.13 1004 273 2.88 / 100.91 2 2
6 13 97.68 18 15.22 502 138 3.02 / 101.04 2 2
7 13 66.28 18 15.22 453 124 3.14 / 101.17 2 2
8 8 0.24 165 15.21 332 833 3.97 / 102.00 2 3
Average= 3.78
(KJ/cycle)

Cycle 25 GMT 20/ 9/2018 10: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 20 15.19 490 149 0.15 / 94.05 2 2
2 7 2004.20 30 14.89 3034 1355 1.50 / 95.41 2 2
3 13 1523.12 18 14.92 2429 652 2.16 / 96.06 2 2
4 13 1022.52 18 15.00 1754 474 2.63 / 96.53 2 2
5 13 489.52 18 15.12 1050 286 2.92 / 96.82 2 2
6 13 94.48 18 15.22 510 140 3.06 / 96.96 2 2
7 13 58.48 18 15.22 444 122 3.18 / 97.08 2 2
8 13 16.80 18 15.23 373 102 3.28 / 97.18 2 2
9 8 0.04 165 15.20 338 848 4.13 / 98.03 2 3
Average= 3.77
(KJ/cycle)

Cycle 24 GMT 10/ 9/2018 11:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 20 15.19 508 154 0.15 / 90.06 2 2
2 7 2001.84 30 14.89 3040 1358 1.51 / 91.42 2 2
3 13 1506.76 18 14.94 2389 642 2.15 / 92.06 2 2
4 13 1003.20 18 15.01 1717 464 2.62 / 92.53 2 2
5 13 469.20 18 15.12 1014 276 2.89 / 92.80 2 2
6 13 91.00 18 15.23 498 137 3.03 / 92.94 2 2
7 13 60.92 18 15.23 444 122 3.15 / 93.06 2 2
8 8 0.08 165 15.21 335 841 3.99 / 93.90 2 5
Average= 3.76
(KJ/cycle)

Cycle 23 GMT 31/ 8/2018 13:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 20 15.19 480 146 0.15 / 85.96 2 2
2 7 2007.12 31 14.87 3094 1426 1.57 / 87.39 2 2
3 13 1483.48 18 14.94 2347 631 2.20 / 88.02 2 2
4 13 1134.48 18 14.99 1884 508 2.71 / 88.53 2 2
5 13 399.96 18 15.15 929 253 2.96 / 88.78 2 2
6 13 102.44 18 15.22 523 143 3.11 / 88.93 2 2
7 13 68.28 18 15.23 463 127 3.24 / 89.05 2 2
8 8 0.08 165 15.21 341 856 4.09 / 89.91 2 4
Average= 3.75
(KJ/cycle)

Cycle 22 GMT 21/ 8/2018 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 19 15.19 490 141 0.14 / 81.93 2 2
2 7 2003.52 30 14.89 3044 1360 1.50 / 83.29 2 2
3 13 1687.56 18 14.90 2680 719 2.22 / 84.01 2 2
4 13 978.36 18 15.03 1669 452 2.67 / 84.46 2 2
5 13 446.36 18 15.14 985 268 2.94 / 84.73 2 2
6 13 78.84 18 15.24 476 131 3.07 / 84.86 2 2
7 13 56.48 18 15.23 434 119 3.19 / 84.98 2 2
8 8 -0.04 165 15.22 333 836 4.03 / 85.82 2 4
Average= 3.73
(KJ/cycle)

Cycle 21 GMT 11/ 8/2018 17:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 19 15.20 490 142 0.14 / 77.91 2 2
2 7 2003.00 30 14.90 3041 1359 1.50 / 79.27 2 2
3 13 1674.04 18 14.91 2626 705 2.21 / 79.98 2 2
4 13 964.28 18 15.04 1663 450 2.66 / 80.43 2 2
5 13 440.24 18 15.15 968 264 2.92 / 80.69 2 2
6 13 81.36 18 15.24 485 133 3.05 / 80.82 2 2
7 13 54.88 18 15.24 437 120 3.17 / 80.94 2 2
8 8 0.04 165 15.22 338 849 4.02 / 81.79 2 4
Average= 3.72
(KJ/cycle)

Cycle 20 GMT 1/ 8/2018 19:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 19 15.20 483 139 0.14 / 73.95 2 2
2 7 2004.64 30 14.91 3029 1355 1.49 / 75.31 2 2
3 13 1667.00 18 14.92 2619 703 2.20 / 76.01 2 2
4 13 963.80 18 15.03 1669 452 2.65 / 76.46 2 2
5 13 294.00 18 15.19 783 214 2.86 / 76.67 2 2
6 13 89.00 18 15.24 496 136 3.00 / 76.81 2 2
7 13 58.56 18 15.25 437 120 3.12 / 76.93 2 2
8 8 0.12 165 15.23 334 839 3.96 / 77.77 2 5
Average= 3.70
(KJ/cycle)

Cycle 19 GMT 22/ 7/2018 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 20 15.20 500 152 0.15 / 70.04 2 2
2 7 2003.44 30 14.92 3011 1348 1.50 / 71.39 2 2
3 13 1522.08 18 14.96 2389 643 2.14 / 72.03 2 2
4 13 1008.60 18 15.04 1695 459 2.60 / 72.49 2 2
5 13 335.20 18 15.19 838 229 2.83 / 72.72 2 2
6 13 80.84 18 15.24 481 132 2.96 / 72.85 2 2
7 13 56.64 18 15.24 438 120 3.08 / 72.97 2 2
8 8 0.08 165 15.23 334 839 3.92 / 73.81 2 5
Average= 3.69
(KJ/cycle)

Cycle 18 GMT 12/ 7/2018 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 19 15.20 507 146 0.15 / 66.10 2 2
2 10 1002.76 2 15.16 1825 55 0.20 / 66.16 2 2
3 3 965.52 -1 15.52 0 0 0.06 / 66.16 2 2
4 7 2004.56 30 14.90 3012 1346 1.55 / 67.51 2 2
5 13 1506.08 18 14.97 2363 637 2.18 / 68.14 2 2
6 13 844.72 18 15.08 1470 399 2.58 / 68.54 2 2
7 13 351.36 18 15.18 862 236 2.82 / 68.78 2 2
8 13 80.40 18 15.24 492 135 2.95 / 68.91 2 2
9 13 50.76 18 15.24 439 120 3.07 / 69.03 2 2
10 8 0.16 165 15.23 341 857 3.93 / 69.89 2 3
Average= 3.68
(KJ/cycle)

Cycle 17 GMT 3/ 7/2018 1: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 19 15.21 474 137 0.14 / 62.16 2 2
2 7 2014.92 31 14.91 3047 1408 1.55 / 63.56 2 2
3 13 1508.20 18 14.96 2379 641 2.19 / 64.20 2 2
4 13 968.40 18 15.05 1655 448 2.63 / 64.65 2 2
5 13 277.56 18 15.20 748 205 2.84 / 64.86 2 2
6 13 67.56 18 15.25 462 127 2.97 / 64.98 2 2
7 13 45.16 18 15.25 422 116 3.08 / 65.10 2 2
8 8 0.20 165 15.23 341 857 3.94 / 65.96 2 5
Average= 3.66
(KJ/cycle)

Cycle 16 GMT 23/ 6/2018 2:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 19 15.22 475 137 0.14 / 58.18 2 2
2 7 2005.20 30 14.92 3033 1358 1.49 / 59.54 2 2
3 13 1666.84 18 14.94 2591 697 2.19 / 60.23 2 2
4 13 983.28 18 15.05 1659 449 2.64 / 60.68 2 2
5 13 449.44 18 15.16 976 266 2.91 / 60.95 2 2
6 13 70.96 18 15.26 461 127 3.03 / 61.07 2 2
7 13 49.68 18 15.26 423 116 3.15 / 61.19 2 2
8 8 0.00 165 15.24 329 827 3.98 / 62.02 2 4
Average= 3.65
(KJ/cycle)

Cycle 15 GMT 13/ 6/2018 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 20 15.22 482 147 0.15 / 54.40 2 2
2 3 969.68 -1 15.54 0 0 0.00 / 54.40 2 2
3 7 2007.24 30 14.92 3014 1349 1.50 / 55.75 2 2
4 13 1513.08 18 14.99 2358 636 2.13 / 56.39 2 2
5 13 848.76 18 15.09 1496 406 2.54 / 56.80 2 2
6 13 209.36 18 15.23 657 180 2.72 / 56.98 2 2
7 13 69.68 18 15.26 452 124 2.84 / 57.10 2 2
8 13 46.48 18 15.26 414 114 2.96 / 57.21 2 2
9 8 0.04 165 15.24 329 827 3.78 / 58.04 2 4
Average= 3.63
(KJ/cycle)

Cycle 14 GMT 3/ 6/2018 6: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 20 15.22 494 150 0.15 / 50.42 2 2
2 3 1036.52 1 15.23 1904 29 0.18 / 50.45 2 2
3 7 2004.76 30 14.93 3014 1350 1.53 / 51.80 2 2
4 13 1506.44 18 14.98 2350 634 2.16 / 52.44 2 2
5 13 993.56 18 15.06 1685 457 2.62 / 52.89 2 2
6 13 463.88 18 15.17 1000 273 2.89 / 53.17 2 2
7 13 80.08 18 15.26 477 131 3.02 / 53.30 2 2
8 13 55.40 18 15.26 436 120 3.14 / 53.42 2 2
9 8 -0.04 165 15.24 334 840 3.98 / 54.26 2 10
Average= 3.62
(KJ/cycle)

Cycle 13 GMT 24/ 5/2018 7:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 20 15.22 467 142 0.14 / 46.48 2 2
2 7 2004.96 30 14.94 3029 1358 1.50 / 47.84 2 2
3 13 1674.16 18 14.96 2586 696 2.20 / 48.53 2 2
4 13 972.76 18 15.07 1645 446 2.64 / 48.98 2 2
5 13 311.68 18 15.21 794 217 2.86 / 49.20 2 2
6 13 79.96 18 15.27 473 130 2.99 / 49.33 2 2
7 13 53.12 18 15.26 427 117 3.11 / 49.45 2 2
8 8 0.08 165 15.25 329 828 3.93 / 50.27 2 4
Average= 3.59
(KJ/cycle)

Cycle 12 GMT 14/ 5/2018 9:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 20 15.23 475 145 0.14 / 42.67 2 2
2 7 2003.76 30 14.93 3034 1359 1.50 / 44.03 2 2
3 13 1482.80 18 15.00 2318 626 2.13 / 44.65 2 2
4 13 836.20 18 15.11 1449 394 2.52 / 45.05 2 2
5 13 329.24 18 15.21 818 224 2.75 / 45.27 2 2
6 13 73.52 18 15.27 463 127 2.87 / 45.40 2 2
7 13 44.60 18 15.27 409 112 2.99 / 45.51 2 2
8 8 -0.08 165 15.24 329 827 3.81 / 46.34 2 7
Average= 3.56
(KJ/cycle)

Cycle 11 GMT 4/ 5/2018 11:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 20 15.23 491 150 0.15 / 38.77 2 2
2 7 2005.84 30 14.93 3051 1367 1.52 / 40.13 2 2
3 13 1509.20 18 14.98 2359 636 2.15 / 40.77 2 2
4 13 972.40 18 15.07 1647 447 2.60 / 41.22 2 2
5 13 415.64 18 15.19 922 252 2.85 / 41.47 2 2
6 13 89.64 18 15.27 478 131 2.98 / 41.60 2 2
7 13 58.68 18 15.27 423 116 3.10 / 41.72 2 2
8 8 0.12 165 15.25 321 808 3.91 / 42.52 2 10
Average= 3.54
(KJ/cycle)

Cycle 10 GMT 24/ 4/2018 13:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 20 15.24 444 135 0.14 / 34.91 2 2
2 7 2005.48 30 14.94 3028 1357 1.49 / 36.27 2 2
3 13 1504.24 18 15.00 2346 633 2.13 / 36.90 2 2
4 13 980.68 18 15.07 1620 439 2.57 / 37.34 2 2
5 13 442.52 18 15.18 943 258 2.82 / 37.60 2 2
6 13 86.36 18 15.28 451 124 2.95 / 37.72 2 2
7 13 58.28 18 15.28 399 110 3.06 / 37.83 2 2
8 8 0.04 165 15.26 313 788 3.84 / 38.62 2 5
Average= 3.51
(KJ/cycle)

Cycle 9 GMT 14/ 4/2018 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 20 15.23 454 138 0.14 / 31.21 2 2
2 7 2003.92 30 14.95 3058 1372 1.51 / 32.59 2 2
3 13 1391.60 18 15.02 2186 591 2.10 / 33.18 2 2
4 13 900.12 18 15.09 1550 421 2.52 / 33.60 2 2
5 13 250.24 18 15.24 691 190 2.71 / 33.79 2 2
6 13 87.52 18 15.28 452 124 2.84 / 33.91 2 2
7 13 56.32 18 15.28 394 108 2.94 / 34.02 2 2
8 8 0.00 165 15.26 299 753 3.70 / 34.77 2 3
Average= 3.48
(KJ/cycle)

Cycle 8 GMT 4/ 4/2018 16:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 20 15.23 452 138 0.14 / 27.30 2 2
2 7 2003.56 37 14.91 2998 1654 1.79 / 28.95 2 2
3 13 1296.04 18 15.04 2052 556 2.35 / 29.51 2 2
4 13 787.44 18 15.12 1385 377 2.72 / 29.88 2 2
5 13 267.88 18 15.23 714 196 2.92 / 30.08 2 2
6 13 75.80 18 15.28 435 120 3.04 / 30.20 2 2
7 13 46.32 18 15.28 381 105 3.14 / 30.30 2 2
8 8 0.04 165 15.26 307 773 3.92 / 31.08 2 7
Average= 3.45
(KJ/cycle)

Cycle 7 GMT 25/ 3/2018 18:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 19 15.24 447 129 0.13 / 23.40 2 2
2 3 1022.36 1 15.25 1868 28 0.16 / 23.43 2 2
3 7 2005.72 36 14.92 2972 1596 1.75 / 25.02 2 2
4 13 1316.32 18 15.03 2072 561 2.31 / 25.58 2 2
5 13 797.68 18 15.12 1401 381 2.70 / 25.96 2 2
6 13 257.76 18 15.24 697 191 2.89 / 26.16 2 2
7 13 80.36 18 15.28 446 123 3.01 / 26.28 2 2
8 13 43.36 18 15.28 382 105 3.12 / 26.38 2 2
9 8 -0.08 165 15.26 308 776 3.89 / 27.16 2 6
Average= 3.39
(KJ/cycle)

Cycle 6 GMT 15/ 3/2018 20:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 21 15.23 451 144 0.14 / 19.65 2 2
2 3 939.24 -1 15.56 0 0 0.00 / 19.65 2 2
3 3 970.60 -1 15.58 0 0 0.00 / 19.65 2 2
4 7 1927.48 36 14.96 2845 1532 1.68 / 21.18 2 2
5 13 1270.52 18 15.05 2028 549 2.23 / 21.73 2 2
6 13 765.20 18 15.13 1354 369 2.59 / 22.10 2 2
7 13 226.56 18 15.25 653 179 2.77 / 22.28 2 2
8 13 71.60 18 15.29 427 118 2.89 / 22.40 2 2
9 13 38.80 18 15.29 366 101 2.99 / 22.50 2 2
10 8 0.04 165 15.27 306 771 3.76 / 23.27 2 5
Average= 3.32
(KJ/cycle)

Cycle 5 GMT 5/ 3/2018 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 23 15.25 453 159 0.16 / 15.82 2 2
2 3 829.72 -3 15.56 0 0 0.00 / 15.82 2 2
3 3 927.24 -1 15.58 0 0 0.00 / 15.82 2 2
4 7 2003.28 36 14.93 2973 1598 1.76 / 17.41 2 2
5 13 1308.40 18 15.05 2037 552 2.31 / 17.97 2 2
6 13 796.40 18 15.12 1392 379 2.69 / 18.34 2 2
7 13 248.28 18 15.24 676 185 2.87 / 18.53 2 2
8 13 65.20 18 15.29 415 114 2.99 / 18.64 2 2
9 13 20.64 18 15.29 337 93 3.08 / 18.74 2 2
10 8 -0.04 165 15.26 305 768 3.85 / 19.51 2 6
Average= 3.25
(KJ/cycle)

Cycle 4 GMT 23/ 2/2018 21:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 21 15.25 445 143 0.14 / 12.55 2 2
2 3 925.56 -1 15.56 0 0 0.00 / 12.55 2 2
3 3 964.96 -1 15.58 0 0 0.00 / 12.55 2 2
4 7 1520.60 36 15.07 2369 1285 1.43 / 13.84 2 2
5 13 1214.60 18 15.10 1902 517 1.94 / 14.35 2 2
6 13 544.80 18 15.20 1073 294 2.24 / 14.65 2 2
7 13 107.00 18 15.29 487 134 2.37 / 14.78 2 2
8 13 63.60 18 15.29 413 114 2.49 / 14.90 2 2
9 8 0.12 165 15.28 302 761 3.25 / 15.66 2 3
Average= 3.13
(KJ/cycle)

Cycle 3 GMT 22/ 2/2018 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 22 15.24 437 147 0.15 / 9.27 2 2
2 3 874.52 -2 15.56 0 0 0.00 / 9.27 2 2
3 3 940.16 -1 15.58 0 0 0.00 / 9.27 2 2
4 7 1516.64 37 15.08 2342 1307 1.45 / 10.58 2 2
5 13 1220.16 18 15.10 1918 521 1.97 / 11.10 2 2
6 13 539.00 18 15.20 1070 293 2.27 / 11.39 2 2
7 13 113.60 18 15.29 499 137 2.40 / 11.53 2 2
8 13 67.28 18 15.30 422 116 2.52 / 11.65 2 2
9 8 -0.04 165 15.28 303 764 3.28 / 12.41 2 4
Average= 3.10
(KJ/cycle)

Cycle 2 GMT 21/ 2/2018 23:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 24 15.26 460 168 0.17 / 5.11 2 2
2 3 773.32 -4 15.58 0 0 0.00 / 5.11 2 2
3 3 908.88 -2 15.60 0 0 0.00 / 5.11 2 2
4 7 1515.28 74 14.98 2337 2591 2.76 / 7.70 2 2
5 13 105.96 22 15.29 490 165 2.92 / 7.86 2 2
6 13 58.52 22 15.30 407 137 3.06 / 8.00 2 2
7 8 -0.04 240 15.26 307 1124 4.19 / 9.13 2 36
Average= 3.04
(KJ/cycle)

Cycle 1 GMT 21/ 2/2018 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 23 15.48 421 150 0.15 / 1.83 2 2
2 3 865.96 -3 15.60 0 0 0.00 / 1.83 2 2
3 3 969.76 -1 15.61 0 0 0.00 / 1.83 2 2
4 7 996.40 74 15.16 1619 1816 1.97 / 3.64 2 2
5 13 48.12 22 15.35 409 138 2.10 / 3.78 2 2
6 8 -0.08 240 15.32 315 1158 3.26 / 4.94 2 33
Average= 2.47
(KJ/cycle)

Cycle 0 GMT 20/ 2/2018 14:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 147.72 22 15.61 498 171 0.17 / 0.17 2 2
2 7 158.08 74 15.58 493 568 0.74 / 0.74 2 2
3 8 0.04 234 15.54 258 938 1.68 / 1.68 2 114
Average= 1.68