SIO Argo Site:
Pump Diagnostics Page   



Serial= 8643 WMO= 5905274

Return

←PreviousNext→

Cycle 255 GMT 16/12/2024 16: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 30 14.88 418 187 0.19 / 1051.75 3 3
2 12 1171.36 3 14.99 1921 86 0.27 / 1051.83 2 3
3 7 2006.28 33 14.51 2935 1405 1.68 / 1053.24 3 2
4 13 1673.08 27 14.50 2509 982 2.66 / 1054.22 2 3
5 13 921.08 27 14.63 1533 606 3.27 / 1054.83 2 2
6 13 193.84 27 14.87 588 236 3.50 / 1055.06 2 3
7 8 0.12 165 14.91 294 723 4.23 / 1055.78 3 3
Average= 4.12
(KJ/cycle)

Cycle 254 GMT 6/12/2024 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.88 431 186 0.19 / 1047.55 3 3
2 12 1198.52 3 14.97 1953 88 0.27 / 1047.63 2 3
3 7 2005.84 32 14.51 2947 1368 1.64 / 1049.00 3 2
4 13 1544.88 27 14.52 2339 917 2.56 / 1049.92 2 2
5 13 837.80 27 14.65 1446 572 3.13 / 1050.49 2 2
6 13 182.64 27 14.87 568 228 3.36 / 1050.72 2 3
7 13 19.44 27 14.93 312 126 3.48 / 1050.84 3 3
8 8 0.08 165 14.90 291 715 4.20 / 1051.56 3 6
Average= 4.12
(KJ/cycle)

Cycle 253 GMT 26/11/2024 20: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 29 14.87 432 186 0.19 / 1043.37 3 3
2 12 1181.44 3 14.99 1950 88 0.27 / 1043.45 2 2
3 7 2004.12 32 14.53 2943 1368 1.64 / 1044.82 2 2
4 13 1509.72 27 14.55 2279 895 2.54 / 1045.72 2 2
5 13 787.76 27 14.68 1368 542 3.08 / 1046.26 2 2
6 13 218.20 27 14.85 631 253 3.33 / 1046.51 2 2
7 13 21.08 27 14.93 319 129 3.46 / 1046.64 2 3
8 8 0.04 165 14.90 292 718 4.18 / 1047.36 3 3
Average= 4.12
(KJ/cycle)

Cycle 252 GMT 16/11/2024 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 29 14.89 431 186 0.19 / 1039.07 3 3
2 12 1164.92 3 14.97 1911 86 0.27 / 1039.16 2 3
3 7 2003.20 32 14.52 2925 1359 1.63 / 1040.52 3 2
4 13 1676.36 27 14.50 2513 984 2.61 / 1041.50 2 2
5 13 774.56 27 14.67 1367 541 3.16 / 1042.04 2 2
6 13 239.28 27 14.84 669 268 3.42 / 1042.31 2 3
7 13 52.20 27 14.91 370 149 3.57 / 1042.46 2 3
8 8 0.00 165 14.88 293 719 4.29 / 1043.18 3 7
Average= 4.12
(KJ/cycle)

Cycle 251 GMT 7/11/2024 0:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 14.88 441 190 0.19 / 1035.08 3 3
2 12 1188.04 3 14.98 1921 86 0.28 / 1035.17 2 3
3 7 2003.00 32 14.51 2929 1360 1.64 / 1036.53 3 2
4 13 1527.80 27 14.53 2321 911 2.55 / 1037.44 2 2
5 13 692.48 27 14.70 1269 504 3.05 / 1037.94 2 2
6 13 186.80 27 14.87 586 235 3.29 / 1038.18 2 3
7 8 0.16 165 14.91 288 709 3.99 / 1038.89 3 3
Average= 4.12
(KJ/cycle)

Cycle 250 GMT 28/10/2024 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 14.88 441 190 0.19 / 1030.93 3 3
2 12 1176.76 3 14.97 1972 89 0.28 / 1031.02 2 3
3 7 2002.96 32 14.52 2923 1358 1.64 / 1032.38 3 2
4 13 1518.72 27 14.54 2289 899 2.54 / 1033.27 2 2
5 13 807.16 27 14.67 1399 554 3.09 / 1033.83 2 2
6 13 160.76 27 14.88 535 215 3.30 / 1034.04 2 3
7 13 37.48 27 14.92 339 137 3.44 / 1034.18 2 3
8 8 0.04 165 14.90 290 713 4.15 / 1034.89 3 3
Average= 4.12
(KJ/cycle)

Cycle 249 GMT 18/10/2024 4:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 29 14.87 451 194 0.19 / 1026.74 3 3
2 12 1178.52 3 14.98 1934 87 0.28 / 1026.83 2 2
3 7 2005.96 32 14.50 2948 1368 1.65 / 1028.19 2 2
4 13 1704.16 27 14.48 2556 999 2.65 / 1029.19 2 2
5 13 624.52 27 14.72 1181 469 3.12 / 1029.66 2 3
6 13 166.68 27 14.88 554 223 3.34 / 1029.89 2 3
7 13 21.52 27 14.93 311 125 3.47 / 1030.01 3 3
8 8 0.08 165 14.90 296 728 4.19 / 1030.74 3 4
Average= 4.12
(KJ/cycle)

Cycle 248 GMT 8/10/2024 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 29 14.87 443 191 0.19 / 1022.52 3 3
2 12 1204.72 3 14.98 1986 89 0.28 / 1022.61 2 2
3 7 2005.76 32 14.51 2944 1367 1.65 / 1023.98 2 2
4 13 1495.20 27 14.54 2266 890 2.54 / 1024.87 2 2
5 13 785.08 27 14.67 1388 550 3.09 / 1025.42 2 3
6 13 215.16 27 14.85 638 256 3.34 / 1025.67 2 3
7 13 41.16 27 14.91 351 141 3.48 / 1025.81 2 3
8 8 0.04 165 14.89 298 732 4.22 / 1026.54 3 4
Average= 4.12
(KJ/cycle)

Cycle 247 GMT 28/ 9/2024 8:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 14.88 433 187 0.19 / 1018.26 3 3
2 12 1173.20 3 14.97 1913 86 0.27 / 1018.35 2 2
3 7 2005.56 32 14.51 2947 1368 1.64 / 1019.72 2 2
4 13 1665.04 27 14.49 2489 974 2.61 / 1020.69 2 3
5 13 751.04 27 14.68 1337 530 3.14 / 1021.22 2 2
6 13 203.12 27 14.85 617 247 3.39 / 1021.47 2 3
7 13 47.08 27 14.91 360 145 3.54 / 1021.61 2 3
8 8 0.04 165 14.89 292 717 4.25 / 1022.33 3 3
Average= 4.12
(KJ/cycle)

Cycle 246 GMT 18/ 9/2024 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 29 14.87 440 190 0.19 / 1013.95 3 3
2 12 1163.72 3 14.99 1962 88 0.28 / 1014.04 2 2
3 7 2003.24 32 14.52 2923 1358 1.64 / 1015.40 2 2
4 13 1664.72 27 14.50 2503 980 2.62 / 1016.38 2 2
5 13 899.96 27 14.64 1520 601 3.22 / 1016.98 2 2
6 13 180.60 27 14.87 578 232 3.45 / 1017.21 2 3
7 13 41.92 27 14.92 353 142 3.59 / 1017.35 2 3
8 8 0.12 165 14.90 293 720 4.31 / 1018.07 3 5
Average= 4.12
(KJ/cycle)

Cycle 245 GMT 8/ 9/2024 12:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 29 14.87 446 192 0.19 / 1009.73 3 3
2 12 1181.40 3 14.98 1968 88 0.28 / 1009.82 2 3
3 7 2005.32 32 14.51 2937 1364 1.64 / 1011.18 3 3
4 13 1529.76 27 14.53 2318 909 2.55 / 1012.09 2 2
5 13 826.04 27 14.66 1438 569 3.12 / 1012.66 2 3
6 13 166.72 27 14.88 560 225 3.35 / 1012.88 2 3
7 13 36.76 27 14.92 351 141 3.49 / 1013.03 3 3
8 8 0.00 165 14.90 300 738 4.23 / 1013.76 3 4
Average= 4.12
(KJ/cycle)

Cycle 244 GMT 29/ 8/2024 14:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 29 14.87 435 188 0.19 / 1005.50 3 3
2 12 1176.64 3 14.98 1964 88 0.28 / 1005.59 2 3
3 7 2002.04 32 14.52 2931 1362 1.64 / 1006.95 3 2
4 13 1534.20 27 14.53 2322 911 2.55 / 1007.86 2 2
5 13 831.88 27 14.66 1438 569 3.12 / 1008.43 2 2
6 13 167.04 27 14.87 556 223 3.34 / 1008.65 2 3
7 13 39.96 27 14.91 364 147 3.49 / 1008.80 2 3
8 8 0.00 165 14.89 300 737 4.22 / 1009.54 3 7
Average= 4.12
(KJ/cycle)

Cycle 243 GMT 19/ 8/2024 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 14.86 446 192 0.19 / 1001.32 3 3
2 12 1176.20 3 14.98 1940 87 0.28 / 1001.41 2 2
3 7 2001.76 32 14.52 2909 1352 1.63 / 1002.76 2 3
4 13 1512.12 27 14.53 2291 899 2.53 / 1003.66 2 2
5 13 774.52 27 14.68 1351 535 3.07 / 1004.20 2 2
6 13 200.56 27 14.86 611 245 3.31 / 1004.44 2 2
7 13 38.52 27 14.91 348 140 3.45 / 1004.58 2 3
8 8 0.08 165 14.89 297 730 4.18 / 1005.31 3 5
Average= 4.12
(KJ/cycle)

Cycle 242 GMT 9/ 8/2024 18:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 29 14.88 426 184 0.18 / 997.11 3 3
2 12 1164.52 3 14.97 1930 87 0.27 / 997.20 2 2
3 7 2003.64 32 14.51 2922 1357 1.63 / 998.55 2 3
4 13 1514.80 27 14.54 2281 895 2.52 / 999.45 2 2
5 13 800.16 27 14.67 1372 543 3.07 / 999.99 2 2
6 13 224.72 27 14.84 648 260 3.33 / 1000.25 2 2
7 13 42.92 27 14.91 356 143 3.47 / 1000.39 2 3
8 8 0.00 165 14.89 300 737 4.21 / 1001.13 3 4
Average= 4.12
(KJ/cycle)

Cycle 241 GMT 30/ 7/2024 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 29 14.88 444 192 0.19 / 992.99 3 3
2 12 1159.72 3 14.98 1946 87 0.28 / 993.08 2 2
3 7 2005.64 32 14.51 2917 1354 1.63 / 994.43 2 2
4 13 1683.48 27 14.49 2506 980 2.61 / 995.41 2 2
5 13 764.96 27 14.68 1357 538 3.15 / 995.95 2 2
6 13 218.32 27 14.85 635 255 3.41 / 996.21 2 2
7 8 0.20 165 14.91 292 718 4.12 / 996.92 3 3
Average= 4.12
(KJ/cycle)

Cycle 240 GMT 20/ 7/2024 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 29 14.87 437 188 0.19 / 989.04 3 3
2 12 1177.40 3 15.00 1918 86 0.27 / 989.13 2 2
3 7 2003.72 32 14.50 2942 1365 1.64 / 990.49 2 2
4 13 1508.24 27 14.54 2279 895 2.53 / 991.39 2 2
5 13 647.32 27 14.71 1184 470 3.00 / 991.86 2 2
6 13 169.72 27 14.88 552 222 3.23 / 992.08 2 3
7 8 0.12 165 14.90 294 723 3.95 / 992.80 3 4
Average= 4.12
(KJ/cycle)

Cycle 239 GMT 11/ 7/2024 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 29 14.86 444 191 0.19 / 984.83 3 3
2 12 1163.92 3 14.95 1966 88 0.28 / 984.92 2 2
3 7 2003.36 32 14.52 2920 1357 1.64 / 986.27 2 3
4 13 1496.32 27 14.54 2277 894 2.53 / 987.17 2 2
5 13 779.96 27 14.67 1382 547 3.08 / 987.72 2 2
6 13 206.48 27 14.85 625 251 3.33 / 987.97 2 3
7 13 38.08 27 14.91 360 145 3.47 / 988.11 2 3
8 8 0.04 165 14.89 301 740 4.21 / 988.85 2 4
Average= 4.12
(KJ/cycle)

Cycle 238 GMT 1/ 7/2024 2:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 29 14.88 440 190 0.19 / 980.58 3 3
2 12 1167.60 3 14.99 1909 86 0.28 / 980.67 2 2
3 7 2004.20 32 14.51 2914 1353 1.63 / 982.02 2 2
4 13 1535.44 27 14.52 2325 911 2.54 / 982.93 2 2
5 13 800.08 27 14.66 1410 558 3.10 / 983.49 2 2
6 13 229.88 27 14.83 663 265 3.36 / 983.75 2 3
7 13 19.92 27 14.91 337 136 3.50 / 983.89 2 3
8 8 0.00 165 14.88 305 749 4.25 / 984.64 3 5
Average= 4.12
(KJ/cycle)

Cycle 237 GMT 21/ 6/2024 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 29 14.86 446 192 0.19 / 976.37 3 3
2 12 1173.36 3 14.99 1970 89 0.28 / 976.46 2 2
3 7 2007.12 32 14.52 2926 1360 1.64 / 977.82 2 2
4 13 1532.88 27 14.53 2306 905 2.54 / 978.73 2 2
5 13 828.32 27 14.66 1424 564 3.11 / 979.29 2 2
6 13 167.68 27 14.87 559 224 3.33 / 979.51 2 2
7 13 39.12 27 14.92 355 143 3.48 / 979.66 2 3
8 8 0.04 165 14.89 298 732 4.21 / 980.39 3 5
Average= 4.12
(KJ/cycle)

Cycle 236 GMT 11/ 6/2024 5:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 30 14.86 454 202 0.20 / 972.11 3 3
2 12 1175.76 3 14.98 1929 87 0.29 / 972.19 2 2
3 7 2007.08 32 14.52 2939 1366 1.65 / 973.56 2 2
4 13 1519.16 27 14.54 2326 913 2.57 / 974.47 2 2
5 13 794.40 27 14.67 1394 552 3.12 / 975.03 2 2
6 13 206.52 27 14.84 635 254 3.37 / 975.28 2 3
7 13 41.48 27 14.90 369 148 3.52 / 975.43 2 3
8 8 -0.08 165 14.87 307 753 4.28 / 976.18 2 11
Average= 4.12
(KJ/cycle)

Cycle 235 GMT 1/ 6/2024 8:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 30 14.86 454 202 0.20 / 967.82 3 3
2 12 1171.84 3 14.98 1924 86 0.29 / 967.90 2 2
3 7 2007.12 33 14.50 2962 1417 1.71 / 969.32 2 2
4 13 1541.36 27 14.53 2342 919 2.62 / 970.24 2 2
5 13 816.72 27 14.66 1421 562 3.19 / 970.80 2 2
6 13 144.12 27 14.88 528 212 3.40 / 971.01 2 2
7 13 16.96 27 14.92 332 134 3.53 / 971.15 2 3
8 8 -0.04 165 14.88 309 759 4.29 / 971.91 3 5
Average= 4.12
(KJ/cycle)

Cycle 234 GMT 22/ 5/2024 10: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 30 14.85 460 205 0.20 / 963.58 3 3
2 12 1193.20 3 14.98 1992 90 0.29 / 963.67 2 3
3 7 2002.44 32 14.53 2921 1358 1.65 / 965.02 3 2
4 13 1505.88 27 14.54 2296 901 2.55 / 965.93 2 3
5 13 782.80 27 14.67 1389 550 3.10 / 966.48 2 3
6 13 214.80 27 14.85 631 253 3.36 / 966.73 2 3
7 13 17.24 27 14.92 331 133 3.49 / 966.86 2 3
8 8 -0.08 165 14.88 306 751 4.24 / 967.61 3 5
Average= 4.12
(KJ/cycle)

Cycle 233 GMT 12/ 5/2024 12:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 30 14.87 444 198 0.20 / 959.20 3 3
2 12 1165.88 3 14.98 1931 87 0.28 / 959.28 2 3
3 7 2002.36 33 14.51 2957 1416 1.70 / 960.70 3 2
4 13 1674.64 27 14.51 2510 983 2.68 / 961.68 2 2
5 13 756.00 27 14.68 1349 535 3.22 / 962.22 2 2
6 13 198.20 27 14.85 621 249 3.47 / 962.47 2 2
7 13 36.68 27 14.91 362 146 3.61 / 962.61 2 3
8 8 0.04 165 14.88 309 759 4.37 / 963.37 3 4
Average= 4.12
(KJ/cycle)

Cycle 232 GMT 2/ 5/2024 14:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 29 14.87 445 192 0.19 / 955.04 3 3
2 12 1187.72 3 14.97 1955 88 0.28 / 955.13 2 2
3 7 2004.52 32 14.52 2946 1369 1.65 / 956.50 2 2
4 13 1680.56 27 14.51 2530 991 2.64 / 957.49 2 2
5 13 770.16 27 14.69 1336 530 3.17 / 958.02 2 2
6 13 199.76 27 14.85 611 245 3.41 / 958.26 2 2
7 8 0.04 165 14.90 300 738 4.15 / 959.00 3 3
Average= 4.12
(KJ/cycle)

Cycle 231 GMT 22/ 4/2024 16:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 29 14.86 463 200 0.20 / 950.88 3 3
2 12 1168.48 3 14.99 1964 88 0.29 / 950.96 2 2
3 7 2005.20 32 14.51 2928 1360 1.65 / 952.32 2 2
4 13 1657.16 27 14.51 2483 973 2.62 / 953.30 2 2
5 13 782.08 27 14.68 1387 550 3.17 / 953.85 2 3
6 13 200.28 27 14.85 621 249 3.42 / 954.10 2 3
7 8 0.12 165 14.89 306 752 4.17 / 954.85 3 5
Average= 4.12
(KJ/cycle)

Cycle 230 GMT 12/ 4/2024 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 29 14.87 453 195 0.20 / 946.84 3 3
2 12 1171.40 3 14.99 1957 88 0.28 / 946.93 2 2
3 7 2008.60 32 14.52 2976 1383 1.67 / 948.31 2 2
4 13 1531.08 27 14.53 2333 915 2.58 / 949.23 2 2
5 13 652.96 27 14.72 1208 480 3.06 / 949.71 2 3
6 13 151.76 27 14.87 544 218 3.28 / 949.92 2 2
7 8 0.08 165 14.90 306 752 4.03 / 950.68 3 6
Average= 4.12
(KJ/cycle)

Cycle 229 GMT 2/ 4/2024 21:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 29 14.87 447 193 0.19 / 942.67 3 3
2 12 1175.68 3 15.00 1951 88 0.28 / 942.76 2 2
3 7 2003.28 32 14.52 2953 1372 1.65 / 944.13 2 2
4 13 1681.40 27 14.51 2519 987 2.64 / 945.12 2 2
5 13 757.88 27 14.68 1350 535 3.17 / 945.65 2 2
6 13 198.76 27 14.85 625 251 3.43 / 945.90 2 3
7 8 -0.04 165 14.90 302 742 4.17 / 946.64 3 3
Average= 4.12
(KJ/cycle)

Cycle 228 GMT 23/ 3/2024 23:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 29 14.87 430 185 0.19 / 938.52 3 3
2 12 1178.16 3 14.99 1934 87 0.27 / 938.61 2 3
3 7 2002.20 32 14.53 2923 1359 1.63 / 939.97 3 2
4 13 1664.64 27 14.52 2493 977 2.61 / 940.95 2 2
5 13 749.56 27 14.69 1339 531 3.14 / 941.48 2 2
6 13 193.60 27 14.85 611 245 3.38 / 941.72 2 3
7 8 0.20 165 14.90 307 755 4.14 / 942.48 3 3
Average= 4.12
(KJ/cycle)

Cycle 227 GMT 14/ 3/2024 1:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 29 14.87 442 191 0.19 / 934.38 3 3
2 12 1174.84 3 14.99 1946 88 0.28 / 934.47 2 2
3 7 2003.76 32 14.53 2951 1372 1.65 / 935.84 2 2
4 13 1671.72 27 14.51 2496 978 2.63 / 936.82 2 2
5 13 755.68 27 14.69 1349 535 3.16 / 937.35 2 2
6 13 189.84 27 14.85 605 243 3.41 / 937.60 2 2
7 8 0.08 165 14.89 302 742 4.15 / 938.34 2 3
Average= 4.12
(KJ/cycle)

Cycle 226 GMT 4/ 3/2024 3:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 29 14.87 439 189 0.19 / 930.38 3 3
2 12 1184.64 3 14.98 1968 88 0.28 / 930.47 2 3
3 7 2006.52 32 14.53 2946 1370 1.65 / 931.84 3 2
4 13 1524.20 27 14.55 2297 902 2.55 / 932.74 2 2
5 13 665.00 27 14.71 1234 490 3.04 / 933.24 2 2
6 13 162.56 27 14.87 553 222 3.26 / 933.46 2 3
7 8 0.08 165 14.90 298 733 3.99 / 934.19 2 3
Average= 4.12
(KJ/cycle)

Cycle 225 GMT 23/ 2/2024 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 29 14.87 458 198 0.20 / 926.40 3 3
2 12 1173.00 3 14.99 1907 86 0.28 / 926.49 2 3
3 7 2003.44 32 14.52 2921 1357 1.64 / 927.85 3 3
4 13 1520.92 27 14.54 2310 907 2.55 / 928.75 2 2
5 13 649.84 27 14.72 1214 482 3.03 / 929.23 2 2
6 13 157.00 27 14.87 548 220 3.25 / 929.45 2 2
7 8 0.12 165 14.90 301 740 3.99 / 930.20 3 3
Average= 4.12
(KJ/cycle)

Cycle 224 GMT 13/ 2/2024 7:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 14.86 453 195 0.20 / 922.25 3 3
2 12 1158.40 3 14.98 1898 85 0.28 / 922.34 2 3
3 7 2007.64 32 14.52 2948 1370 1.65 / 923.71 3 3
4 13 1688.28 27 14.51 2529 991 2.64 / 924.70 2 3
5 13 756.88 27 14.68 1355 537 3.18 / 925.23 2 2
6 13 138.20 27 14.88 540 217 3.40 / 925.45 2 3
7 8 0.00 165 14.90 307 755 4.15 / 926.21 2 6
Average= 4.12
(KJ/cycle)

Cycle 223 GMT 3/ 2/2024 9:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 14.88 440 190 0.19 / 918.02 3 3
2 12 1164.12 3 15.00 1923 87 0.28 / 918.11 2 3
3 7 2004.08 32 14.52 2943 1367 1.64 / 919.48 3 2
4 13 1534.56 27 14.53 2322 911 2.55 / 920.39 2 2
5 13 804.36 27 14.67 1404 556 3.11 / 920.94 2 2
6 13 140.56 27 14.87 526 211 3.32 / 921.15 2 2
7 13 32.84 27 14.91 356 143 3.47 / 921.30 2 3
8 8 0.20 165 14.88 309 759 4.22 / 922.06 2 4
Average= 4.12
(KJ/cycle)

Cycle 222 GMT 24/ 1/2024 11: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 29 14.86 461 199 0.20 / 913.99 3 3
2 12 1165.60 3 14.98 1936 87 0.29 / 914.08 2 2
3 7 2002.40 33 14.52 2938 1408 1.69 / 915.49 2 2
4 13 1498.24 27 14.55 2297 902 2.60 / 916.39 2 2
5 13 654.72 27 14.71 1220 485 3.08 / 916.88 2 2
6 13 163.72 27 14.87 553 222 3.30 / 917.10 2 2
7 8 0.04 165 14.90 298 733 4.04 / 917.83 3 4
Average= 4.12
(KJ/cycle)

Cycle 221 GMT 14/ 1/2024 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 29 14.86 458 197 0.20 / 909.75 3 3
2 3 1021.12 1 14.97 1784 27 0.22 / 909.77 2 2
3 12 1179.28 3 14.99 1937 87 0.31 / 909.86 2 2
4 7 2005.40 32 14.53 2938 1366 1.68 / 911.23 2 2
5 13 1514.40 27 14.55 2305 906 2.58 / 912.13 2 2
6 13 770.60 27 14.68 1365 541 3.12 / 912.67 2 2
7 13 214.32 27 14.85 625 251 3.37 / 912.92 2 3
8 13 19.52 27 14.92 320 129 3.50 / 913.05 2 3
9 8 -0.12 165 14.89 303 744 4.25 / 913.80 3 6
Average= 4.12
(KJ/cycle)

Cycle 220 GMT 4/ 1/2024 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 14.87 462 199 0.20 / 905.67 3 3
2 12 1188.84 3 14.99 1976 89 0.29 / 905.76 2 2
3 7 2002.56 32 14.53 2928 1361 1.65 / 907.12 2 3
4 13 1501.00 27 14.55 2292 900 2.55 / 908.02 2 2
5 13 767.16 27 14.68 1348 534 3.08 / 908.56 2 2
6 13 198.20 27 14.86 605 243 3.33 / 908.80 2 3
7 8 0.08 165 14.89 305 749 4.08 / 909.55 2 5
Average= 4.12
(KJ/cycle)

Cycle 219 GMT 25/12/2023 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 29 14.87 454 196 0.20 / 901.42 3 3
2 12 1168.40 3 15.00 1960 88 0.28 / 901.50 2 2
3 7 2003.92 32 14.54 2940 1368 1.65 / 902.87 2 2
4 13 1675.80 27 14.52 2500 980 2.63 / 903.85 2 2
5 13 897.28 27 14.64 1523 602 3.23 / 904.45 2 2
6 13 182.20 27 14.87 588 236 3.47 / 904.69 2 3
7 8 0.12 165 14.90 318 782 4.25 / 905.47 3 4
Average= 4.12
(KJ/cycle)

Cycle 218 GMT 15/12/2023 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 14.88 441 190 0.19 / 897.31 3 3
2 12 1175.52 3 15.00 1959 88 0.28 / 897.40 2 2
3 7 2004.68 32 14.54 2929 1363 1.64 / 898.77 2 2
4 13 1524.88 27 14.55 2310 907 2.55 / 899.67 2 2
5 13 807.92 27 14.67 1419 562 3.11 / 900.23 2 2
6 13 145.44 27 14.88 533 214 3.32 / 900.45 2 2
7 8 0.12 165 14.89 314 771 4.10 / 901.22 2 7
Average= 4.12
(KJ/cycle)

Cycle 217 GMT 5/12/2023 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 29 14.86 441 190 0.19 / 893.24 3 3
2 12 1184.48 3 14.99 1980 89 0.28 / 893.33 2 3
3 7 2004.92 32 14.53 2930 1362 1.64 / 894.69 3 3
4 13 1515.20 27 14.55 2310 907 2.55 / 895.60 2 3
5 13 798.44 27 14.67 1407 557 3.11 / 896.16 2 2
6 13 145.00 27 14.88 528 212 3.32 / 896.37 2 2
7 8 0.20 165 14.90 306 752 4.07 / 897.12 3 6
Average= 4.12
(KJ/cycle)

Cycle 216 GMT 25/11/2023 23:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 29 14.87 443 191 0.19 / 889.09 3 3
2 12 1173.04 3 15.00 1948 88 0.28 / 889.18 2 3
3 7 2004.92 33 14.53 2932 1406 1.68 / 890.59 3 3
4 13 1514.84 27 14.55 2307 906 2.59 / 891.49 2 2
5 13 786.96 27 14.68 1394 553 3.14 / 892.04 2 2
6 13 209.80 27 14.84 637 255 3.40 / 892.30 2 2
7 8 0.04 165 14.89 307 754 4.15 / 893.05 2 4
Average= 4.12
(KJ/cycle)

Cycle 215 GMT 16/11/2023 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 29 14.88 459 198 0.20 / 885.09 3 3
2 12 1177.72 3 14.98 1948 88 0.29 / 885.18 2 2
3 7 2006.56 32 14.52 2937 1365 1.65 / 886.54 2 2
4 13 1505.12 27 14.55 2307 906 2.56 / 887.45 2 2
5 13 642.72 27 14.72 1209 481 3.04 / 887.93 2 3
6 13 151.84 27 14.87 546 219 3.26 / 888.15 2 2
7 8 0.12 165 14.90 307 755 4.01 / 888.90 2 4
Average= 4.12
(KJ/cycle)

Cycle 214 GMT 6/11/2023 3:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 29 14.87 441 190 0.19 / 881.01 3 3
2 12 1170.32 3 15.00 1959 88 0.28 / 881.10 2 3
3 7 2007.08 32 14.53 2954 1373 1.65 / 882.48 3 3
4 13 1530.00 27 14.55 2317 910 2.56 / 883.39 2 2
5 13 793.64 27 14.68 1390 551 3.11 / 883.94 2 2
6 13 144.80 27 14.88 530 213 3.33 / 884.15 2 2
7 8 0.04 165 14.90 301 740 4.07 / 884.89 2 5
Average= 4.12
(KJ/cycle)

Cycle 213 GMT 27/10/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 29 14.87 454 196 0.20 / 876.97 3 3
2 12 1165.84 3 15.00 1907 86 0.28 / 877.06 2 3
3 7 2002.12 32 14.53 2910 1353 1.63 / 878.41 3 2
4 13 1493.84 27 14.57 2253 886 2.52 / 879.30 2 2
5 13 762.20 27 14.68 1348 534 3.06 / 879.83 2 2
6 13 177.96 27 14.86 584 234 3.29 / 880.06 2 2
7 8 0.20 165 14.89 309 759 4.05 / 880.82 3 4
Average= 4.12
(KJ/cycle)

Cycle 212 GMT 17/10/2023 7:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 29 14.86 461 199 0.20 / 872.99 3 3
2 12 1191.48 3 15.00 1942 87 0.29 / 873.07 2 2
3 7 2004.68 32 14.54 2919 1358 1.64 / 874.43 2 2
4 13 1499.36 27 14.57 2269 893 2.54 / 875.32 2 2
5 13 657.92 27 14.72 1225 487 3.02 / 875.81 2 3
6 13 157.60 27 14.88 547 220 3.24 / 876.03 2 2
7 8 0.04 165 14.90 303 745 3.99 / 876.77 3 3
Average= 4.12
(KJ/cycle)

Cycle 211 GMT 7/10/2023 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 29 14.88 451 195 0.19 / 868.65 3 3
2 12 1196.92 3 14.99 1976 89 0.28 / 868.74 2 3
3 7 2007.16 32 14.53 2947 1370 1.65 / 870.11 3 2
4 13 1681.68 27 14.52 2502 981 2.63 / 871.09 2 2
5 13 763.64 27 14.69 1363 541 3.18 / 871.63 2 3
6 13 205.48 27 14.85 629 252 3.43 / 871.89 2 2
7 13 41.00 27 14.91 369 149 3.58 / 872.04 2 3
8 8 0.00 165 14.88 306 751 4.33 / 872.79 3 7
Average= 4.12
(KJ/cycle)

Cycle 210 GMT 27/ 9/2023 11:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 14.88 440 190 0.19 / 864.58 3 3
2 12 1180.24 3 14.98 1966 88 0.28 / 864.66 2 2
3 7 2002.72 32 14.53 2940 1367 1.65 / 866.03 2 3
4 13 1518.76 27 14.56 2304 906 2.55 / 866.94 2 2
5 13 818.88 27 14.67 1422 563 3.11 / 867.50 2 2
6 13 154.60 27 14.88 541 217 3.33 / 867.72 2 2
7 8 0.04 165 14.90 302 742 4.07 / 868.46 3 3
Average= 4.12
(KJ/cycle)

Cycle 209 GMT 17/ 9/2023 13:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.88 435 188 0.19 / 860.53 3 3
2 12 1173.36 3 14.99 1925 87 0.27 / 860.62 2 2
3 7 2005.20 32 14.54 2914 1356 1.63 / 861.97 2 2
4 13 1535.68 27 14.55 2296 902 2.53 / 862.88 2 2
5 13 806.28 27 14.68 1405 557 3.09 / 863.43 2 2
6 13 154.40 27 14.89 528 212 3.30 / 863.64 2 3
7 8 0.24 165 14.91 301 741 4.04 / 864.39 3 4
Average= 4.12
(KJ/cycle)

Cycle 208 GMT 7/ 9/2023 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 29 14.88 437 189 0.19 / 856.32 3 3
2 12 1163.04 3 15.00 1925 87 0.28 / 856.41 2 2
3 7 2003.60 32 14.53 2956 1374 1.65 / 857.79 2 2
4 13 1531.64 27 14.55 2330 915 2.56 / 858.70 2 2
5 13 813.12 27 14.67 1411 559 3.12 / 859.26 2 2
6 13 153.28 27 14.88 537 216 3.34 / 859.48 2 3
7 13 35.08 27 14.92 343 138 3.48 / 859.61 2 3
8 8 0.04 165 14.90 297 730 4.21 / 860.34 3 10
Average= 4.12
(KJ/cycle)

Cycle 207 GMT 28/ 8/2023 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 29 14.88 446 192 0.19 / 852.31 3 3
2 12 1170.80 3 14.99 1927 87 0.28 / 852.40 2 3
3 7 2009.00 32 14.54 2928 1362 1.64 / 853.76 3 2
4 13 1507.64 27 14.56 2294 902 2.54 / 854.66 2 3
5 13 775.04 27 14.69 1367 542 3.09 / 855.21 2 2
6 13 140.52 27 14.89 506 203 3.29 / 855.41 2 3
7 8 0.08 165 14.91 295 726 4.01 / 856.14 3 3
Average= 4.12
(KJ/cycle)

Cycle 206 GMT 18/ 8/2023 19:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 29 14.88 435 188 0.19 / 848.16 3 3
2 12 1177.52 3 14.99 1969 89 0.28 / 848.25 2 3
3 7 2004.84 32 14.53 2943 1368 1.64 / 849.61 3 2
4 13 1507.60 27 14.56 2285 898 2.54 / 850.51 2 2
5 13 777.32 27 14.69 1361 540 3.08 / 851.05 2 3
6 13 140.68 27 14.89 505 203 3.29 / 851.26 2 3
7 13 34.52 27 14.92 341 137 3.42 / 851.39 2 3
8 8 0.16 165 14.90 296 728 4.15 / 852.12 3 5
Average= 4.12
(KJ/cycle)

Cycle 205 GMT 8/ 8/2023 21:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 29 14.87 433 187 0.19 / 843.78 3 3
2 12 1172.20 3 15.01 1939 87 0.27 / 843.87 2 3
3 7 2003.32 32 14.55 2918 1359 1.63 / 845.23 3 2
4 13 1658.76 27 14.53 2457 964 2.60 / 846.19 2 2
5 13 753.60 27 14.70 1332 529 3.13 / 846.72 2 3
6 13 197.68 27 14.86 602 242 3.37 / 846.96 2 2
7 13 44.88 27 14.92 361 145 3.51 / 847.11 2 3
8 8 -0.04 165 14.89 298 732 4.24 / 847.84 3 7
9 14 -0.04 30 14.87 297 132 4.38 / 847.97 3 14
Average= 4.12
(KJ/cycle)

Cycle 204 GMT 29/ 7/2023 23:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.88 427 184 0.18 / 839.59 3 3
2 12 1175.12 3 14.99 1953 88 0.27 / 839.67 2 3
3 7 2002.92 32 14.54 2928 1362 1.63 / 841.04 3 2
4 13 1515.68 27 14.57 2275 895 2.53 / 841.93 2 2
5 13 778.72 27 14.69 1372 544 3.07 / 842.48 2 2
6 13 208.20 27 14.86 629 252 3.33 / 842.73 2 3
7 13 18.36 27 14.92 324 131 3.46 / 842.86 2 3
8 8 0.04 165 14.89 299 735 4.19 / 843.59 3 4
Average= 4.12
(KJ/cycle)

Cycle 203 GMT 20/ 7/2023 1:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 29 14.88 447 193 0.19 / 835.53 3 3
2 12 1179.68 3 14.99 1971 89 0.28 / 835.62 2 2
3 7 2006.80 32 14.54 2927 1362 1.64 / 836.98 2 3
4 13 1519.92 27 14.57 2303 906 2.55 / 837.89 2 2
5 13 814.52 27 14.67 1421 563 3.11 / 838.45 2 2
6 13 154.04 27 14.88 532 214 3.33 / 838.66 2 3
7 8 0.16 165 14.91 301 741 4.07 / 839.40 2 3
Average= 4.11
(KJ/cycle)

Cycle 202 GMT 10/ 7/2023 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 29 14.86 455 196 0.20 / 831.47 3 3
2 12 1160.72 3 15.01 1933 87 0.28 / 831.56 2 2
3 7 2003.28 32 14.55 2930 1364 1.65 / 832.92 2 3
4 13 1512.00 27 14.57 2261 889 2.54 / 833.81 2 2
5 13 789.16 27 14.69 1385 549 3.09 / 834.36 2 2
6 13 214.52 27 14.86 625 251 3.34 / 834.61 2 3
7 8 0.08 165 14.91 294 723 4.06 / 835.34 3 6
Average= 4.11
(KJ/cycle)

Cycle 201 GMT 30/ 6/2023 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 14.89 434 187 0.19 / 827.22 3 3
2 12 1164.28 3 15.00 1921 86 0.27 / 827.30 2 3
3 7 2004.76 32 14.55 2911 1355 1.63 / 828.66 3 3
4 13 1535.52 27 14.55 2331 916 2.54 / 829.57 2 2
5 13 798.36 27 14.69 1379 547 3.09 / 830.12 2 2
6 13 216.36 27 14.85 636 255 3.35 / 830.38 2 2
7 13 38.00 27 14.91 362 146 3.49 / 830.52 2 3
8 8 -0.08 165 14.89 307 754 4.25 / 831.28 3 6
Average= 4.12
(KJ/cycle)

Cycle 200 GMT 20/ 6/2023 7:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 29 14.86 442 190 0.19 / 823.16 3 3
2 12 1184.52 3 14.99 1973 89 0.28 / 823.25 2 3
3 7 2006.32 32 14.54 2936 1366 1.65 / 824.62 3 3
4 13 1526.00 27 14.56 2299 904 2.55 / 825.52 2 2
5 13 797.12 27 14.68 1409 558 3.11 / 826.08 2 2
6 13 143.04 27 14.89 525 211 3.32 / 826.29 2 3
7 8 0.12 165 14.91 300 738 4.06 / 827.03 3 3
Average= 4.11
(KJ/cycle)

Cycle 199 GMT 10/ 6/2023 9:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 29 14.89 431 186 0.19 / 818.85 3 3
2 12 1185.56 3 15.00 1994 90 0.28 / 818.94 2 3
3 7 2003.84 32 14.55 2924 1361 1.64 / 820.30 3 2
4 13 1673.88 27 14.53 2499 980 2.62 / 821.28 2 2
5 13 760.48 27 14.70 1349 535 3.15 / 821.81 2 3
6 13 187.56 27 14.86 610 245 3.40 / 822.06 2 3
7 13 36.28 27 14.92 365 147 3.54 / 822.21 2 3
8 8 -0.04 165 14.89 312 767 4.31 / 822.97 3 7
Average= 4.11
(KJ/cycle)

Cycle 198 GMT 31/ 5/2023 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 29 14.88 453 195 0.20 / 814.74 3 3
2 12 1184.56 3 15.02 1948 88 0.28 / 814.83 2 2
3 7 2003.56 32 14.55 2923 1361 1.64 / 816.19 2 2
4 13 1507.80 27 14.57 2283 898 2.54 / 817.09 2 2
5 13 815.20 27 14.68 1428 566 3.11 / 817.65 2 3
6 13 226.52 27 14.84 659 264 3.37 / 817.92 2 2
7 8 0.16 165 14.90 303 745 4.12 / 818.66 2 3
Average= 4.11
(KJ/cycle)

Cycle 197 GMT 21/ 5/2023 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 29 14.87 444 191 0.19 / 810.69 3 3
2 12 1171.00 3 15.00 1980 89 0.28 / 810.77 2 2
3 7 2004.76 32 14.55 2940 1369 1.65 / 812.14 2 3
4 13 1513.64 27 14.56 2297 903 2.55 / 813.05 2 2
5 13 799.40 27 14.69 1398 554 3.11 / 813.60 2 3
6 13 145.36 27 14.89 526 211 3.32 / 813.81 2 3
7 8 0.08 165 14.91 297 731 4.05 / 814.54 3 3
Average= 4.11
(KJ/cycle)

Cycle 196 GMT 11/ 5/2023 15:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 29 14.88 439 189 0.19 / 806.40 3 3
2 12 1191.36 3 14.98 1980 89 0.28 / 806.49 2 3
3 7 2005.92 32 14.55 2952 1374 1.65 / 807.87 3 2
4 13 1671.96 27 14.53 2506 983 2.64 / 808.85 2 2
5 13 748.52 27 14.71 1336 531 3.17 / 809.38 2 2
6 13 186.92 27 14.87 599 240 3.41 / 809.62 2 3
7 13 17.80 27 14.93 325 131 3.54 / 809.75 2 3
8 8 0.00 165 14.90 302 742 4.28 / 810.49 2 6
Average= 4.11
(KJ/cycle)

Cycle 195 GMT 1/ 5/2023 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 29 14.88 454 196 0.20 / 802.19 3 3
2 12 1185.96 3 15.01 1960 88 0.28 / 802.28 2 2
3 7 2003.88 32 14.55 2916 1358 1.64 / 803.64 2 2
4 13 1522.72 27 14.55 2315 909 2.55 / 804.55 2 2
5 13 810.92 27 14.69 1406 558 3.11 / 805.11 2 2
6 13 148.28 27 14.89 536 215 3.32 / 805.32 2 3
7 13 17.12 27 14.93 334 135 3.46 / 805.46 2 3
8 8 0.08 165 14.90 308 757 4.22 / 806.21 3 9
Average= 4.11
(KJ/cycle)

Cycle 194 GMT 21/ 4/2023 19: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 29 14.87 449 194 0.19 / 798.09 3 3
2 12 1184.12 3 15.00 1933 87 0.28 / 798.18 2 2
3 7 2002.44 32 14.54 2938 1367 1.65 / 799.55 2 2
4 13 1507.76 27 14.57 2284 899 2.55 / 800.45 2 2
5 13 777.52 27 14.70 1355 538 3.08 / 800.98 2 2
6 13 204.76 27 14.86 624 250 3.33 / 801.23 2 3
7 8 0.20 165 14.91 310 763 4.10 / 802.00 3 5
Average= 4.11
(KJ/cycle)

Cycle 193 GMT 11/ 4/2023 21:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 14.90 442 191 0.19 / 793.76 3 3
2 12 1188.84 3 14.99 1950 88 0.28 / 793.84 2 2
3 7 2005.44 32 14.55 2941 1369 1.65 / 795.21 2 3
4 13 1666.12 27 14.54 2504 983 2.63 / 796.20 2 2
5 13 776.24 27 14.70 1374 545 3.18 / 796.74 2 3
6 13 215.64 27 14.86 636 255 3.43 / 797.00 2 2
7 13 40.36 27 14.92 367 148 3.58 / 797.14 2 3
8 8 -0.04 165 14.89 308 757 4.34 / 797.90 3 4
Average= 4.11
(KJ/cycle)

Cycle 192 GMT 1/ 4/2023 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 14.89 447 193 0.19 / 789.68 3 3
2 12 1164.36 3 15.02 1914 86 0.28 / 789.77 2 2
3 7 2003.52 32 14.55 2918 1359 1.64 / 791.13 2 2
4 13 1513.32 27 14.57 2298 904 2.54 / 792.03 2 2
5 13 798.84 27 14.69 1405 557 3.10 / 792.59 2 3
6 13 147.56 27 14.90 537 216 3.32 / 792.81 2 3
7 8 0.16 165 14.92 308 758 4.07 / 793.56 3 3
Average= 4.11
(KJ/cycle)

Cycle 191 GMT 23/ 3/2023 1:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 29 14.89 442 191 0.19 / 785.60 3 3
2 12 1171.96 3 15.02 1946 88 0.28 / 785.69 2 2
3 7 2004.56 32 14.56 2930 1365 1.64 / 787.05 2 2
4 13 1519.36 27 14.57 2317 911 2.56 / 787.96 2 2
5 13 815.72 27 14.69 1434 569 3.12 / 788.53 2 3
6 13 149.84 27 14.89 540 217 3.34 / 788.75 2 2
7 8 0.16 165 14.92 302 743 4.08 / 789.49 3 5
Average= 4.11
(KJ/cycle)

Cycle 190 GMT 13/ 3/2023 3: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 29 14.87 457 197 0.20 / 781.43 3 3
2 12 1163.20 3 15.00 1936 87 0.28 / 781.52 2 3
3 7 2004.08 32 14.55 2944 1371 1.65 / 782.89 3 3
4 13 1662.84 27 14.54 2504 983 2.64 / 783.87 2 3
5 13 783.32 27 14.70 1390 552 3.19 / 784.42 2 2
6 13 139.08 27 14.90 531 214 3.40 / 784.64 2 3
7 8 0.20 165 14.91 313 770 4.17 / 785.41 3 4
Average= 4.11
(KJ/cycle)

Cycle 189 GMT 3/ 3/2023 4:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 29 14.88 456 197 0.20 / 777.23 3 3
2 12 1156.08 3 15.01 1940 87 0.28 / 777.32 2 3
3 7 2007.96 32 14.55 2933 1366 1.65 / 778.68 3 3
4 13 1514.44 27 14.58 2271 894 2.54 / 779.57 2 2
5 13 789.48 27 14.70 1391 552 3.10 / 780.13 2 2
6 13 130.56 27 14.90 527 212 3.31 / 780.34 2 3
7 13 16.48 27 14.94 334 135 3.44 / 780.47 2 3
8 8 0.04 165 14.90 309 760 4.20 / 781.23 3 8
Average= 4.11
(KJ/cycle)

Cycle 188 GMT 21/ 2/2023 6:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 29 14.88 454 196 0.20 / 773.17 3 3
2 12 1172.92 3 15.00 1971 89 0.28 / 773.26 2 3
3 7 2006.00 32 14.56 2921 1361 1.65 / 774.62 3 3
4 13 1537.44 27 14.57 2306 907 2.55 / 775.53 2 2
5 13 703.12 27 14.72 1272 506 3.06 / 776.04 2 2
6 13 153.76 27 14.89 558 224 3.28 / 776.26 2 3
7 8 0.00 165 14.91 313 770 4.05 / 777.03 3 7
Average= 4.11
(KJ/cycle)

Cycle 187 GMT 11/ 2/2023 8:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 29 14.89 452 195 0.20 / 768.96 3 3
2 12 1167.04 3 15.02 1928 87 0.28 / 769.05 2 2
3 7 2008.08 32 14.55 2931 1365 1.65 / 770.41 2 2
4 13 1539.04 27 14.58 2291 902 2.55 / 771.32 2 2
5 13 793.76 27 14.70 1379 547 3.10 / 771.86 2 2
6 13 127.16 27 14.90 520 209 3.31 / 772.07 2 3
7 8 0.24 165 14.91 312 768 4.07 / 772.84 3 3
8 14 0.24 30 14.88 311 139 4.21 / 772.98 2 4
Average= 4.11
(KJ/cycle)

Cycle 186 GMT 1/ 2/2023 10:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 29 14.88 461 199 0.20 / 764.88 3 3
2 12 1171.40 3 15.01 1953 88 0.29 / 764.96 2 3
3 7 2002.60 32 14.55 2934 1366 1.65 / 766.33 3 3
4 13 1505.52 27 14.58 2286 900 2.55 / 767.23 2 2
5 13 805.12 27 14.70 1405 558 3.11 / 767.79 2 2
6 13 132.40 27 14.90 524 211 3.32 / 768.00 2 3
7 8 0.12 165 14.92 312 768 4.09 / 768.77 3 4
Average= 4.11
(KJ/cycle)

Cycle 185 GMT 22/ 1/2023 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 29 14.89 442 191 0.19 / 760.63 3 3
2 12 1177.16 3 15.00 1957 88 0.28 / 760.72 2 2
3 7 2005.00 32 14.55 2933 1366 1.64 / 762.09 2 2
4 13 1511.68 27 14.58 2297 904 2.55 / 762.99 2 2
5 13 790.80 27 14.70 1394 553 3.10 / 763.54 2 2
6 13 126.68 27 14.90 510 205 3.31 / 763.75 2 3
7 13 28.84 27 14.93 370 149 3.46 / 763.90 2 3
8 8 0.04 165 14.90 317 779 4.24 / 764.68 2 5
Average= 4.11
(KJ/cycle)

Cycle 184 GMT 12/ 1/2023 14: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 14.90 441 191 0.19 / 756.42 3 3
2 12 1176.12 3 15.02 1921 87 0.28 / 756.51 2 3
3 7 2010.20 32 14.55 2939 1368 1.65 / 757.87 3 2
4 13 1524.60 27 14.58 2295 903 2.55 / 758.78 2 3
5 13 797.80 27 14.70 1414 561 3.11 / 759.34 2 2
6 13 137.32 27 14.90 515 207 3.32 / 759.55 2 3
7 13 31.24 27 14.94 353 142 3.46 / 759.69 2 3
8 8 0.00 165 14.91 306 753 4.21 / 760.44 3 3
Average= 4.11
(KJ/cycle)

Cycle 183 GMT 2/ 1/2023 15:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 29 14.89 441 190 0.19 / 752.36 3 3
2 12 1159.28 3 15.02 1896 85 0.28 / 752.44 2 3
3 7 2006.36 32 14.54 2939 1367 1.64 / 753.81 3 2
4 13 1514.96 27 14.57 2312 910 2.55 / 754.72 2 2
5 13 787.36 27 14.70 1394 553 3.11 / 755.27 2 3
6 13 136.68 27 14.91 520 209 3.32 / 755.48 2 3
7 8 0.08 165 14.92 304 748 4.06 / 756.23 3 6
Average= 4.11
(KJ/cycle)

Cycle 182 GMT 23/12/2022 17:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 29 14.89 435 188 0.19 / 748.30 3 3
2 12 1173.36 3 15.02 1899 86 0.27 / 748.38 2 2
3 7 2002.96 32 14.55 2923 1361 1.63 / 749.74 2 3
4 13 1515.32 27 14.58 2311 910 2.54 / 750.65 2 2
5 13 791.72 27 14.70 1404 557 3.10 / 751.21 2 3
6 13 141.76 27 14.90 534 215 3.32 / 751.42 2 2
7 8 0.04 165 14.92 301 741 4.06 / 752.17 3 4
Average= 4.11
(KJ/cycle)

Cycle 181 GMT 13/12/2022 19:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 29 14.88 443 191 0.19 / 744.08 3 3
2 12 1173.84 3 15.00 1948 88 0.28 / 744.17 2 2
3 7 2007.24 32 14.55 2933 1366 1.64 / 745.54 2 2
4 13 1515.88 27 14.57 2306 907 2.55 / 746.44 2 2
5 13 756.00 27 14.72 1327 527 3.08 / 746.97 2 2
6 13 190.08 27 14.88 607 244 3.32 / 747.22 2 2
7 13 37.00 27 14.93 359 145 3.47 / 747.36 2 3
8 8 0.00 165 14.91 304 748 4.22 / 748.11 2 4
Average= 4.11
(KJ/cycle)

Cycle 180 GMT 3/12/2022 21:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 29 14.90 430 186 0.19 / 739.79 3 3
2 12 1164.56 3 15.03 1914 86 0.27 / 739.88 2 3
3 7 2003.88 32 14.56 2905 1353 1.63 / 741.23 3 3
4 13 1681.64 27 14.54 2479 973 2.60 / 742.20 2 2
5 13 762.80 27 14.72 1354 538 3.14 / 742.74 2 2
6 13 195.04 27 14.88 613 246 3.38 / 742.99 2 2
7 13 41.88 27 14.93 371 150 3.53 / 743.14 2 3
8 8 -0.08 165 14.91 307 755 4.29 / 743.89 3 5
Average= 4.11
(KJ/cycle)

Cycle 179 GMT 23/11/2022 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 29 14.90 441 191 0.19 / 735.73 3 3
2 12 1187.60 3 15.01 1970 89 0.28 / 735.82 2 2
3 7 2002.32 33 14.55 2923 1403 1.68 / 737.22 2 2
4 13 1500.36 27 14.57 2289 900 2.58 / 738.12 2 2
5 13 775.32 27 14.71 1372 545 3.13 / 738.67 2 2
6 13 139.24 27 14.91 516 208 3.34 / 738.87 2 3
7 8 0.00 165 14.93 297 732 4.07 / 739.60 3 3
Average= 4.11
(KJ/cycle)

Cycle 178 GMT 14/11/2022 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 29 14.90 431 186 0.19 / 731.68 3 3
2 12 1160.44 3 15.04 1908 86 0.27 / 731.76 2 2
3 7 2003.28 32 14.55 2951 1374 1.65 / 733.14 2 2
4 13 1510.00 27 14.58 2304 907 2.55 / 734.04 2 2
5 13 792.16 27 14.71 1379 548 3.10 / 734.59 2 2
6 13 142.16 27 14.91 525 211 3.31 / 734.80 2 3
7 8 0.04 165 14.93 298 734 4.05 / 735.54 3 5
Average= 4.11
(KJ/cycle)

Cycle 177 GMT 4/11/2022 3:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 29 14.89 443 191 0.19 / 727.49 3 3
2 12 1158.28 3 15.03 1906 86 0.28 / 727.58 2 3
3 7 2008.16 32 14.56 2933 1367 1.64 / 728.95 3 3
4 13 1506.84 27 14.59 2298 905 2.55 / 729.85 2 3
5 13 799.28 27 14.71 1402 557 3.11 / 730.41 2 3
6 13 143.64 27 14.91 530 213 3.32 / 730.62 2 3
7 13 35.40 27 14.94 350 141 3.46 / 730.76 2 3
8 8 0.00 165 14.92 296 729 4.19 / 731.49 3 5
Average= 4.11
(KJ/cycle)

Cycle 176 GMT 25/10/2022 5:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 29 14.88 440 190 0.19 / 723.27 3 3
2 12 1179.04 3 15.01 1918 86 0.28 / 723.35 2 3
3 7 2005.28 32 14.56 2925 1363 1.64 / 724.72 3 3
4 13 1515.24 27 14.58 2298 905 2.54 / 725.62 2 3
5 13 776.08 27 14.71 1380 548 3.09 / 726.17 2 3
6 13 200.44 27 14.88 614 247 3.34 / 726.42 2 3
7 13 42.64 27 14.94 369 149 3.49 / 726.57 2 3
8 8 -0.04 165 14.91 299 736 4.22 / 727.30 3 6
Average= 4.11
(KJ/cycle)

Cycle 175 GMT 15/10/2022 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.90 424 183 0.18 / 719.05 3 3
2 12 1185.76 3 15.01 1938 87 0.27 / 719.14 2 3
3 7 2002.16 32 14.55 2940 1369 1.64 / 720.51 3 2
4 13 1505.64 27 14.59 2258 889 2.53 / 721.40 2 3
5 13 768.72 27 14.72 1365 543 3.07 / 721.94 2 3
6 13 189.88 27 14.89 600 241 3.31 / 722.18 2 2
7 13 34.76 27 14.94 362 146 3.46 / 722.33 3 3
8 8 0.00 165 14.91 306 753 4.21 / 723.08 3 5
Average= 4.11
(KJ/cycle)

Cycle 174 GMT 5/10/2022 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 29 14.92 428 185 0.19 / 714.85 3 3
2 12 1174.60 3 15.04 1923 87 0.27 / 714.94 2 3
3 7 2005.24 32 14.56 2942 1371 1.64 / 716.31 3 2
4 13 1525.52 27 14.58 2317 912 2.55 / 717.22 2 2
5 13 811.84 27 14.70 1413 561 3.12 / 717.78 2 2
6 13 157.76 27 14.91 543 219 3.33 / 718.00 2 3
7 13 36.60 27 14.95 349 141 3.48 / 718.14 2 3
8 8 0.00 165 14.92 296 729 4.20 / 718.87 3 6
Average= 4.11
(KJ/cycle)

Cycle 173 GMT 25/ 9/2022 11: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 29 14.90 441 191 0.19 / 710.74 3 3
2 12 1169.08 3 15.02 1958 88 0.28 / 710.83 2 3
3 7 2007.76 33 14.55 2967 1425 1.70 / 712.26 3 3
4 13 1518.68 27 14.58 2320 913 2.62 / 713.17 2 2
5 13 787.16 27 14.71 1387 551 3.17 / 713.72 2 3
6 13 147.64 27 14.92 531 214 3.38 / 713.93 2 3
7 8 0.24 165 14.94 296 730 4.11 / 714.66 3 3
Average= 4.11
(KJ/cycle)

Cycle 172 GMT 15/ 9/2022 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 29 14.90 421 182 0.18 / 706.51 3 3
2 12 1194.16 3 15.02 1983 89 0.27 / 706.60 2 3
3 7 2007.16 32 14.56 2935 1367 1.64 / 707.96 3 2
4 13 1526.32 27 14.59 2286 901 2.54 / 708.86 2 2
5 13 788.52 27 14.72 1387 551 3.09 / 709.41 2 2
6 13 213.76 27 14.88 632 254 3.34 / 709.67 2 2
7 13 42.08 27 14.94 360 145 3.49 / 709.81 2 3
8 8 0.04 165 14.92 300 739 4.23 / 710.55 3 6
Average= 4.11
(KJ/cycle)

Cycle 171 GMT 5/ 9/2022 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 29 14.90 438 189 0.19 / 702.27 3 3
2 12 1172.04 3 15.00 1946 88 0.28 / 702.35 2 3
3 7 2004.00 32 14.57 2939 1370 1.65 / 703.73 3 2
4 13 1509.20 27 14.59 2310 910 2.56 / 704.64 2 2
5 13 789.24 27 14.72 1389 552 3.11 / 705.19 2 2
6 13 221.56 27 14.88 649 261 3.37 / 705.45 2 3
7 13 42.48 27 14.94 360 145 3.52 / 705.59 2 3
8 8 0.04 165 14.92 297 731 4.25 / 706.32 3 6
Average= 4.11
(KJ/cycle)

Cycle 170 GMT 26/ 8/2022 17: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 29 14.90 438 189 0.19 / 698.07 3 3
2 12 1183.68 3 15.01 1973 89 0.28 / 698.16 2 3
3 7 2003.84 32 14.57 2938 1370 1.65 / 699.53 3 2
4 13 1490.72 27 14.60 2261 891 2.54 / 700.42 2 2
5 13 761.96 27 14.73 1350 537 3.08 / 700.96 2 3
6 13 175.40 27 14.90 580 233 3.31 / 701.19 2 3
7 13 37.48 27 14.95 355 143 3.45 / 701.33 2 3
8 8 0.00 165 14.92 303 746 4.20 / 702.08 3 6
Average= 4.11
(KJ/cycle)

Cycle 169 GMT 16/ 8/2022 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 29 14.91 441 191 0.19 / 693.73 3 3
2 12 1177.20 3 15.02 1954 88 0.28 / 693.81 2 2
3 7 2004.28 33 14.56 2931 1408 1.69 / 695.22 2 2
4 13 1666.92 27 14.55 2499 982 2.67 / 696.20 2 2
5 13 766.96 27 14.72 1358 540 3.21 / 696.74 2 3
6 13 196.92 27 14.89 611 246 3.45 / 696.99 2 2
7 13 40.88 27 14.95 359 145 3.60 / 697.13 2 3
8 8 0.04 165 14.92 303 746 4.34 / 697.88 3 7
Average= 4.11
(KJ/cycle)

Cycle 168 GMT 6/ 8/2022 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 29 14.92 446 193 0.19 / 689.48 3 3
2 12 1170.44 3 15.03 1940 87 0.28 / 689.57 2 2
3 7 2005.08 32 14.55 2940 1369 1.65 / 690.94 2 2
4 13 1526.28 27 14.59 2314 912 2.56 / 691.85 2 3
5 13 785.76 27 14.72 1387 551 3.11 / 692.40 2 2
6 13 212.40 27 14.89 633 254 3.37 / 692.65 2 2
7 13 43.56 27 14.95 360 145 3.51 / 692.80 2 3
8 8 -0.08 165 14.92 299 736 4.25 / 693.53 3 4
Average= 4.10
(KJ/cycle)

Cycle 167 GMT 27/ 7/2022 23:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 29 14.92 436 189 0.19 / 685.41 3 3
2 12 1182.60 3 15.04 1960 88 0.28 / 685.50 2 3
3 7 2006.08 32 14.57 2941 1371 1.65 / 686.87 3 3
4 13 1526.16 27 14.58 2315 911 2.56 / 687.78 2 2
5 13 794.64 27 14.71 1388 551 3.11 / 688.33 2 3
6 13 143.84 27 14.92 520 209 3.32 / 688.54 2 3
7 8 0.12 165 14.94 301 742 4.06 / 689.29 3 3
Average= 4.10
(KJ/cycle)

Cycle 166 GMT 18/ 7/2022 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 14.92 434 188 0.19 / 681.37 3 3
2 12 1173.44 3 15.04 1935 87 0.28 / 681.46 2 3
3 7 2002.12 33 14.55 2907 1396 1.67 / 682.85 3 2
4 13 1496.32 27 14.59 2267 893 2.56 / 683.75 2 2
5 13 756.64 27 14.73 1340 533 3.10 / 684.28 2 2
6 13 129.48 27 14.93 500 202 3.30 / 684.48 2 3
7 8 0.12 165 14.94 302 744 4.04 / 685.22 3 4
Average= 4.10
(KJ/cycle)

Cycle 165 GMT 8/ 7/2022 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 14.92 435 188 0.19 / 677.37 3 3
2 12 1165.80 3 15.04 1918 87 0.27 / 677.46 2 2
3 7 2003.48 32 14.55 2942 1370 1.64 / 678.83 2 3
4 13 1513.24 27 14.58 2304 907 2.55 / 679.74 2 2
5 13 640.24 27 14.76 1207 481 3.03 / 680.22 2 2
6 13 146.32 27 14.92 535 216 3.25 / 680.43 2 2
7 8 0.04 165 14.94 303 747 4.00 / 681.18 3 4
Average= 4.10
(KJ/cycle)

Cycle 164 GMT 28/ 6/2022 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 29 14.91 443 192 0.19 / 673.17 3 3
2 12 1168.76 3 15.00 1941 87 0.28 / 673.26 2 3
3 7 2006.68 32 14.56 2953 1376 1.65 / 674.64 3 2
4 13 1498.68 27 14.59 2282 899 2.55 / 675.54 2 2
5 13 789.16 27 14.72 1388 552 3.11 / 676.09 2 2
6 13 142.16 27 14.92 524 211 3.32 / 676.30 2 3
7 13 29.92 27 14.96 351 142 3.46 / 676.44 2 3
8 8 0.00 165 14.93 303 746 4.20 / 677.19 3 5
Average= 4.10
(KJ/cycle)

Cycle 163 GMT 18/ 6/2022 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 29 14.91 440 190 0.19 / 669.05 3 3
2 12 1163.20 3 15.03 1936 87 0.28 / 669.14 2 3
3 7 2003.60 32 14.57 2931 1367 1.64 / 670.50 3 3
4 13 1390.16 27 14.61 2144 846 2.49 / 671.35 2 2
5 13 709.28 27 14.74 1292 514 3.00 / 671.86 2 2
6 13 175.44 27 14.90 570 229 3.23 / 672.09 2 2
7 13 34.40 27 14.95 356 144 3.38 / 672.24 2 3
8 8 0.04 165 14.93 303 746 4.12 / 672.98 3 6
Average= 4.10
(KJ/cycle)

Cycle 162 GMT 8/ 6/2022 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 29 14.92 450 195 0.19 / 664.74 3 3
2 12 1176.32 3 15.02 1908 86 0.28 / 664.82 2 3
3 7 2008.40 32 14.57 2932 1367 1.65 / 666.19 3 3
4 13 1682.48 27 14.55 2484 976 2.62 / 667.17 2 2
5 13 773.96 27 14.73 1362 542 3.17 / 667.71 2 3
6 13 222.76 27 14.89 650 261 3.43 / 667.97 2 2
7 13 19.88 27 14.97 332 134 3.56 / 668.10 2 3
8 8 0.04 165 14.93 306 754 4.31 / 668.86 3 4
Average= 4.10
(KJ/cycle)

Cycle 161 GMT 29/ 5/2022 9:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 29 14.92 438 190 0.19 / 660.66 3 3
2 12 1189.24 3 15.02 1975 89 0.28 / 660.75 2 2
3 7 2001.20 32 14.56 2928 1364 1.64 / 662.11 2 2
4 13 1485.08 27 14.60 2265 893 2.54 / 663.01 2 2
5 13 753.32 27 14.74 1354 539 3.07 / 663.55 2 2
6 13 187.40 27 14.91 592 238 3.31 / 663.78 2 3
7 8 0.12 165 14.94 308 759 4.07 / 664.54 3 3
Average= 4.10
(KJ/cycle)

Cycle 160 GMT 19/ 5/2022 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 29 14.91 448 194 0.19 / 656.58 3 3
2 12 1186.36 3 15.00 1974 89 0.28 / 656.67 2 2
3 7 2005.12 33 14.56 2936 1411 1.69 / 658.08 2 2
4 13 1489.96 27 14.59 2273 895 2.59 / 658.98 2 2
5 13 770.12 27 14.72 1370 544 3.13 / 659.52 2 2
6 13 135.52 27 14.93 505 204 3.34 / 659.72 2 2
7 8 0.08 165 14.95 303 747 4.08 / 660.47 3 5
Average= 4.10
(KJ/cycle)

Cycle 159 GMT 9/ 5/2022 14: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 29 14.92 432 187 0.19 / 652.27 3 3
2 12 1162.52 3 15.02 1936 87 0.27 / 652.36 2 3
3 7 2004.04 32 14.57 2937 1369 1.64 / 653.73 3 2
4 13 1520.36 27 14.58 2310 909 2.55 / 654.64 2 2
5 13 805.88 27 14.72 1416 563 3.12 / 655.20 2 3
6 13 228.20 27 14.88 671 270 3.39 / 655.47 2 3
7 13 46.88 27 14.95 379 153 3.54 / 655.63 2 3
8 8 0.04 165 14.93 309 761 4.30 / 656.39 3 4
Average= 4.10
(KJ/cycle)

Cycle 158 GMT 29/ 4/2022 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 29 14.92 452 196 0.20 / 648.24 3 3
2 12 1153.64 3 15.02 1904 86 0.28 / 648.33 2 2
3 7 2006.60 33 14.57 2912 1400 1.68 / 649.73 2 2
4 13 1504.20 27 14.60 2278 898 2.58 / 650.63 2 2
5 13 657.44 27 14.77 1227 489 3.07 / 651.12 2 2
6 13 156.08 27 14.92 546 220 3.29 / 651.34 2 2
7 8 0.12 165 14.95 304 750 4.04 / 652.09 3 3
Average= 4.10
(KJ/cycle)

Cycle 157 GMT 19/ 4/2022 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 29 14.92 447 193 0.19 / 643.88 3 3
2 12 1187.28 3 15.01 1959 88 0.28 / 643.97 2 3
3 7 2003.72 32 14.57 2943 1372 1.65 / 645.34 3 3
4 13 1489.12 27 14.59 2286 901 2.55 / 646.24 2 2
5 13 795.28 27 14.72 1392 553 3.11 / 646.80 2 2
6 13 153.40 27 14.93 544 219 3.33 / 647.02 2 3
7 13 32.48 27 14.97 356 144 3.47 / 647.16 2 3
8 8 -0.08 165 14.94 306 754 4.23 / 647.91 3 6
9 14 -0.08 30 14.92 303 136 4.36 / 648.05 2 6
Average= 4.10
(KJ/cycle)

Cycle 156 GMT 9/ 4/2022 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 29 14.91 438 189 0.19 / 639.88 3 3
2 12 1166.92 3 15.03 1946 88 0.28 / 639.97 2 2
3 7 2002.52 32 14.55 2945 1371 1.65 / 641.34 2 2
4 13 1499.52 27 14.59 2282 899 2.55 / 642.24 2 2
5 13 639.60 27 14.78 1195 477 3.02 / 642.72 2 2
6 13 144.32 27 14.94 529 213 3.24 / 642.93 2 3
7 8 0.08 165 14.95 307 757 3.99 / 643.69 3 3
Average= 4.10
(KJ/cycle)

Cycle 155 GMT 30/ 3/2022 20:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 29 14.93 444 192 0.19 / 635.54 3 3
2 12 1172.76 3 15.03 1951 88 0.28 / 635.63 2 3
3 7 2003.72 32 14.58 2928 1366 1.65 / 637.00 3 2
4 13 1680.04 27 14.56 2503 984 2.63 / 637.98 2 2
5 13 778.88 27 14.73 1384 550 3.18 / 638.53 2 3
6 13 218.96 27 14.90 646 260 3.44 / 638.79 2 3
7 13 18.36 27 14.97 338 137 3.58 / 638.93 2 3
8 8 -0.08 165 14.93 311 766 4.34 / 639.69 2 6
Average= 4.10
(KJ/cycle)

Cycle 154 GMT 20/ 3/2022 23: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 29 14.92 446 193 0.19 / 631.47 3 3
2 12 1168.28 3 15.03 1961 88 0.28 / 631.56 2 3
3 7 2004.88 32 14.57 2933 1367 1.65 / 632.93 3 2
4 13 1523.92 27 14.59 2307 909 2.56 / 633.83 2 2
5 13 784.12 27 14.73 1387 552 3.11 / 634.39 2 2
6 13 139.80 27 14.94 527 213 3.32 / 634.60 2 3
7 8 0.04 165 14.95 305 752 4.07 / 635.35 3 6
Average= 4.10
(KJ/cycle)

Cycle 153 GMT 11/ 3/2022 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 29 14.92 443 192 0.19 / 627.23 3 3
2 12 1192.88 3 15.03 1979 89 0.28 / 627.32 2 3
3 7 2004.76 32 14.58 2941 1372 1.65 / 628.69 3 3
4 13 1680.76 27 14.56 2505 985 2.64 / 629.68 2 3
5 13 787.40 27 14.73 1398 556 3.19 / 630.23 2 2
6 13 236.52 27 14.90 674 271 3.46 / 630.50 2 3
7 8 0.16 165 14.95 313 772 4.24 / 631.28 3 3
Average= 4.10
(KJ/cycle)

Cycle 152 GMT 1/ 3/2022 2:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 14.92 461 199 0.20 / 623.04 3 3
2 12 1187.16 3 15.04 1968 89 0.29 / 623.13 2 2
3 7 2004.92 33 14.58 2928 1409 1.70 / 624.54 2 3
4 13 1529.88 27 14.58 2340 921 2.62 / 625.46 2 2
5 13 795.48 27 14.73 1397 556 3.17 / 626.02 2 2
6 13 213.64 27 14.91 636 256 3.43 / 626.27 2 3
7 8 0.00 165 14.95 311 767 4.20 / 627.04 2 5
Average= 4.10
(KJ/cycle)

Cycle 151 GMT 19/ 2/2022 4:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 29 14.93 460 199 0.20 / 619.00 3 3
2 12 1184.72 3 15.03 1968 89 0.29 / 619.09 2 2
3 7 2004.60 32 14.58 2954 1378 1.67 / 620.47 2 2
4 13 1528.48 27 14.59 2319 914 2.58 / 621.38 2 2
5 13 668.16 27 14.77 1239 494 3.07 / 621.88 2 3
6 13 164.72 27 14.94 551 222 3.30 / 622.10 2 3
7 8 0.00 165 14.96 301 743 4.04 / 622.84 3 4
Average= 4.10
(KJ/cycle)

Cycle 150 GMT 9/ 2/2022 6:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 29 14.93 436 189 0.19 / 614.91 3 3
2 12 1181.16 3 15.03 1936 87 0.28 / 615.00 2 2
3 7 2002.84 33 14.57 2931 1409 1.69 / 616.41 2 3
4 13 1506.96 27 14.59 2297 905 2.59 / 617.31 2 3
5 13 782.52 27 14.74 1362 542 3.13 / 617.85 2 3
6 13 141.96 27 14.94 518 209 3.34 / 618.06 2 3
7 8 0.04 165 14.96 300 741 4.08 / 618.80 3 4
Average= 4.10
(KJ/cycle)

Cycle 149 GMT 30/ 1/2022 8:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 29 14.94 435 188 0.19 / 610.94 3 3
2 12 1175.24 3 15.03 1963 89 0.28 / 611.03 2 2
3 7 2002.96 32 14.58 2928 1366 1.64 / 612.39 2 3
4 13 1513.88 27 14.60 2273 896 2.54 / 613.29 2 2
5 13 628.72 27 14.79 1189 475 3.01 / 613.76 2 3
6 13 155.84 27 14.94 540 218 3.23 / 613.98 2 3
7 8 0.16 165 14.96 300 741 3.97 / 614.72 3 3
Average= 4.10
(KJ/cycle)

Cycle 148 GMT 20/ 1/2022 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 29 14.94 459 199 0.20 / 606.88 3 3
2 12 1184.16 3 15.04 1946 88 0.29 / 606.97 2 2
3 7 2002.24 32 14.59 2910 1359 1.65 / 608.33 2 3
4 13 1501.12 27 14.61 2255 890 2.53 / 609.22 2 3
5 13 769.12 27 14.75 1366 544 3.08 / 609.76 2 3
6 13 212.24 27 14.91 625 252 3.33 / 610.01 2 3
7 8 0.16 165 14.96 298 736 4.07 / 610.75 3 4
Average= 4.10
(KJ/cycle)

Cycle 147 GMT 10/ 1/2022 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 29 14.93 433 187 0.19 / 602.87 3 3
2 12 1190.60 3 15.04 1967 89 0.28 / 602.96 2 3
3 7 2008.96 32 14.57 2927 1365 1.64 / 604.32 3 2
4 13 1522.80 27 14.59 2328 917 2.56 / 605.24 2 3
5 13 643.96 27 14.79 1207 482 3.04 / 605.72 2 2
6 13 175.84 27 14.94 563 227 3.27 / 605.95 2 2
7 8 0.24 165 14.97 298 736 4.00 / 606.68 3 4
Average= 4.10
(KJ/cycle)

Cycle 146 GMT 31/12/2021 13:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 29 14.94 437 189 0.19 / 598.83 3 3
2 12 1177.56 3 15.03 1952 88 0.28 / 598.92 2 3
3 7 2002.68 32 14.58 2948 1375 1.65 / 600.29 3 3
4 13 1531.40 27 14.59 2323 915 2.57 / 601.21 2 2
5 13 671.64 27 14.78 1242 496 3.06 / 601.70 2 2
6 13 171.60 27 14.93 571 230 3.29 / 601.93 2 3
7 8 0.04 165 14.96 303 748 4.04 / 602.68 3 4
Average= 4.10
(KJ/cycle)

Cycle 145 GMT 21/12/2021 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 29 14.93 457 198 0.20 / 594.67 3 3
2 12 1174.12 3 15.05 1955 88 0.29 / 594.75 2 2
3 7 2006.64 32 14.56 2929 1365 1.65 / 596.12 2 2
4 13 1662.84 27 14.56 2496 981 2.63 / 597.10 2 2
5 13 752.60 27 14.75 1346 536 3.17 / 597.64 2 2
6 13 209.68 27 14.92 631 254 3.42 / 597.89 2 2
7 8 0.04 165 14.96 303 748 4.17 / 598.64 2 3
Average= 4.10
(KJ/cycle)

Cycle 144 GMT 11/12/2021 17:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 29 14.93 442 191 0.19 / 590.43 3 3
2 12 1179.40 3 15.02 1974 89 0.28 / 590.52 2 2
3 7 2003.28 32 14.59 2907 1357 1.64 / 591.88 2 2
4 13 1670.88 27 14.57 2493 981 2.62 / 592.86 2 2
5 13 923.04 27 14.69 1565 621 3.24 / 593.48 2 2
6 13 191.16 27 14.93 592 239 3.48 / 593.72 2 3
7 8 0.12 165 14.96 303 748 4.23 / 594.47 2 5
Average= 4.10
(KJ/cycle)

Cycle 143 GMT 1/12/2021 19:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 29 14.93 450 195 0.19 / 586.32 3 3
2 12 1174.48 3 15.01 1943 87 0.28 / 586.41 2 3
3 7 2003.36 32 14.57 2948 1374 1.66 / 587.78 3 2
4 13 1518.52 27 14.59 2316 912 2.57 / 588.69 2 2
5 13 796.28 27 14.73 1400 557 3.13 / 589.25 2 2
6 13 210.72 27 14.91 632 254 3.38 / 589.50 2 2
7 8 0.04 165 14.97 299 739 4.12 / 590.24 3 5
Average= 4.10
(KJ/cycle)

Cycle 142 GMT 21/11/2021 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 14.93 449 194 0.19 / 582.12 3 3
2 12 1182.00 3 15.04 1940 88 0.28 / 582.21 2 2
3 7 2003.52 32 14.57 2940 1371 1.65 / 583.58 2 3
4 13 1492.48 27 14.61 2276 898 2.55 / 584.48 2 3
5 13 751.88 27 14.75 1345 536 3.09 / 585.01 2 3
6 13 202.00 27 14.93 606 244 3.33 / 585.26 2 3
7 13 21.84 27 14.99 329 133 3.46 / 585.39 3 3
8 8 0.20 165 14.96 298 736 4.20 / 586.12 3 5
Average= 4.10
(KJ/cycle)

Cycle 141 GMT 11/11/2021 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 14.94 442 192 0.19 / 577.87 3 3
2 12 1166.08 3 15.02 1938 87 0.28 / 577.95 2 2
3 7 2005.00 32 14.58 2934 1369 1.65 / 579.32 2 2
4 13 1489.84 27 14.61 2277 898 2.55 / 580.22 2 2
5 13 779.28 27 14.75 1382 550 3.10 / 580.77 2 2
6 13 210.36 27 14.92 627 253 3.35 / 581.02 2 2
7 13 42.72 27 14.98 371 150 3.50 / 581.17 2 3
8 8 -0.04 165 14.95 304 750 4.25 / 581.92 3 4
Average= 4.10
(KJ/cycle)

Cycle 140 GMT 2/11/2021 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 29 14.94 433 188 0.19 / 573.73 3 3
2 12 1176.28 3 15.05 1946 88 0.28 / 573.81 2 2
3 7 2004.76 32 14.58 2946 1374 1.65 / 575.19 2 2
4 13 1518.12 27 14.60 2307 909 2.56 / 576.10 2 2
5 13 658.84 27 14.78 1232 492 3.05 / 576.59 2 3
6 13 175.36 27 14.94 561 226 3.28 / 576.82 2 3
7 13 21.40 27 15.00 320 130 3.41 / 576.95 2 3
8 8 -0.04 165 14.96 296 731 4.14 / 577.68 3 5
Average= 4.10
(KJ/cycle)

Cycle 139 GMT 23/10/2021 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.92 29 14.96 462 200 0.20 / 569.63 3 3
2 12 1179.96 3 15.04 1966 89 0.29 / 569.72 2 3
3 7 2004.00 32 14.58 2938 1371 1.66 / 571.09 3 2
4 13 1497.52 27 14.62 2260 892 2.55 / 571.98 2 2
5 13 645.96 27 14.80 1182 472 3.02 / 572.45 2 3
6 13 188.76 27 14.94 573 231 3.26 / 572.68 2 3
7 13 21.80 27 15.00 321 130 3.39 / 572.81 3 3
8 8 -0.08 165 14.97 293 724 4.11 / 573.54 3 4
Average= 4.10
(KJ/cycle)

Cycle 138 GMT 13/10/2021 4:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 29 14.93 440 191 0.19 / 565.55 3 3
2 12 1184.44 3 15.02 1975 89 0.28 / 565.64 2 2
3 7 2006.12 32 14.58 2944 1374 1.65 / 567.01 2 3
4 13 1507.76 27 14.62 2287 903 2.56 / 567.92 2 2
5 13 798.80 27 14.74 1400 557 3.11 / 568.47 2 3
6 13 163.16 27 14.95 554 224 3.34 / 568.70 2 3
7 8 0.36 165 14.98 296 732 4.07 / 569.43 3 4
Average= 4.10
(KJ/cycle)

Cycle 137 GMT 3/10/2021 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 29 14.95 439 190 0.19 / 561.44 3 3
2 12 1175.64 3 15.04 1940 88 0.28 / 561.52 2 3
3 7 2004.28 32 14.60 2928 1368 1.65 / 562.89 3 2
4 13 1395.12 27 14.64 2161 854 2.50 / 563.75 2 2
5 13 682.76 27 14.78 1248 498 3.00 / 564.24 2 3
6 13 168.84 27 14.94 566 228 3.23 / 564.47 2 3
7 13 38.96 27 14.98 364 147 3.37 / 564.62 2 3
8 8 0.12 165 14.96 300 741 4.11 / 565.36 3 4
Average= 4.10
(KJ/cycle)

Cycle 136 GMT 23/ 9/2021 8:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 29 14.93 440 191 0.19 / 557.26 3 3
2 12 1185.40 3 15.05 1967 89 0.28 / 557.35 2 3
3 7 2005.60 33 14.59 2941 1416 1.70 / 558.77 3 2
4 13 1511.08 27 14.61 2295 905 2.60 / 559.67 2 3
5 13 641.00 27 14.80 1202 480 3.08 / 560.15 2 3
6 13 152.64 27 14.96 537 217 3.30 / 560.37 2 3
7 13 19.04 27 15.00 326 132 3.43 / 560.50 2 3
8 8 0.00 165 14.97 301 743 4.17 / 561.25 3 4
Average= 4.10
(KJ/cycle)

Cycle 135 GMT 13/ 9/2021 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 29 14.94 443 192 0.19 / 552.96 3 3
2 12 1178.84 3 15.05 1941 88 0.28 / 553.04 2 2
3 7 2007.96 32 14.57 2950 1375 1.65 / 554.42 2 2
4 13 1512.00 27 14.61 2302 908 2.56 / 555.33 2 3
5 13 797.60 27 14.74 1401 558 3.12 / 555.89 2 2
6 13 216.52 27 14.92 653 263 3.38 / 556.15 2 3
7 13 37.48 27 14.98 377 152 3.54 / 556.30 2 3
8 8 -0.08 165 14.95 313 772 4.31 / 557.07 3 5
Average= 4.10
(KJ/cycle)

Cycle 134 GMT 3/ 9/2021 12: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 29 14.94 429 186 0.19 / 548.86 3 3
2 12 1178.12 3 15.04 1951 88 0.27 / 548.95 2 2
3 7 2001.60 32 14.59 2928 1367 1.64 / 550.32 2 3
4 13 1487.48 27 14.62 2271 896 2.54 / 551.21 2 2
5 13 773.84 27 14.76 1375 548 3.09 / 551.76 2 3
6 13 184.64 27 14.93 604 243 3.33 / 552.00 2 3
7 8 0.00 165 14.97 308 761 4.09 / 552.77 3 5
Average= 4.09
(KJ/cycle)

Cycle 133 GMT 24/ 8/2021 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 29 14.94 443 192 0.19 / 544.57 3 3
2 12 1166.68 3 15.04 1960 88 0.28 / 544.66 2 3
3 7 2005.76 33 14.58 2955 1422 1.70 / 546.08 3 3
4 13 1524.52 27 14.60 2324 916 2.62 / 547.00 2 2
5 13 810.48 27 14.75 1416 564 3.18 / 547.56 2 3
6 13 135.92 27 14.96 523 211 3.39 / 547.77 2 3
7 13 32.56 27 14.99 354 143 3.54 / 547.92 2 3
8 8 0.04 165 14.96 307 758 4.29 / 548.68 3 5
Average= 4.09
(KJ/cycle)

Cycle 132 GMT 14/ 8/2021 15:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 29 14.94 453 196 0.20 / 540.13 3 3
2 12 1168.68 3 15.04 1950 88 0.28 / 540.22 2 2
3 7 2008.88 32 14.59 2948 1376 1.66 / 541.60 2 2
4 13 1690.24 27 14.57 2529 995 2.66 / 542.59 2 2
5 13 945.52 27 14.70 1595 633 3.29 / 543.23 2 2
6 13 186.08 27 14.94 596 240 3.53 / 543.47 2 3
7 13 42.40 27 14.99 371 150 3.68 / 543.62 2 3
8 8 0.00 165 14.96 310 765 4.44 / 544.38 3 5
Average= 4.09
(KJ/cycle)

Cycle 131 GMT 4/ 8/2021 17:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 14.94 439 190 0.19 / 535.84 3 3
2 12 1184.44 3 15.05 1969 89 0.28 / 535.93 2 3
3 7 2005.64 32 14.59 2936 1371 1.65 / 537.30 3 2
4 13 1510.52 27 14.62 2303 909 2.56 / 538.21 2 2
5 13 795.84 27 14.75 1406 560 3.12 / 538.77 2 2
6 13 219.48 27 14.92 650 262 3.38 / 539.03 2 3
7 13 23.92 27 15.00 338 137 3.52 / 539.17 2 3
8 8 -0.08 165 14.96 310 765 4.28 / 539.94 3 4
Average= 4.09
(KJ/cycle)

Cycle 130 GMT 25/ 7/2021 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 29 14.94 441 191 0.19 / 531.42 3 3
2 12 1165.36 3 15.05 1966 89 0.28 / 531.51 2 3
3 7 2005.36 32 14.59 2949 1377 1.66 / 532.89 3 3
4 13 1523.04 27 14.61 2314 913 2.57 / 533.80 2 3
5 13 790.48 27 14.76 1397 557 3.13 / 534.36 2 3
6 13 213.16 27 14.93 633 255 3.38 / 534.61 2 2
7 13 47.72 27 14.99 371 150 3.53 / 534.76 2 3
8 8 0.00 165 14.96 307 758 4.29 / 535.52 3 5
9 14 0.00 30 14.94 296 133 4.42 / 535.65 3 9
Average= 4.09
(KJ/cycle)

Cycle 129 GMT 15/ 7/2021 21:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 29 14.95 448 194 0.19 / 527.14 3 3
2 12 1179.24 3 15.07 1943 88 0.28 / 527.23 2 2
3 7 2005.32 32 14.60 2947 1377 1.66 / 528.61 2 3
4 13 1506.32 27 14.62 2291 904 2.56 / 529.51 2 3
5 13 792.60 27 14.76 1403 559 3.12 / 530.07 2 2
6 13 216.16 27 14.93 644 260 3.38 / 530.33 2 3
7 13 45.20 27 14.99 375 152 3.53 / 530.48 2 3
8 8 0.08 165 14.97 303 748 4.28 / 531.23 3 3
Average= 4.09
(KJ/cycle)

Cycle 128 GMT 5/ 7/2021 23:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 29 14.95 447 194 0.19 / 522.91 3 3
2 12 1168.20 3 15.06 1914 86 0.28 / 522.99 2 3
3 7 2005.72 32 14.60 2929 1368 1.65 / 524.36 3 2
4 13 1532.76 27 14.62 2322 917 2.57 / 525.28 2 2
5 13 801.48 27 14.76 1403 559 3.12 / 525.84 2 2
6 13 157.64 27 14.97 540 218 3.34 / 526.05 2 3
7 13 39.12 27 15.01 355 144 3.49 / 526.20 3 3
8 8 0.12 165 14.98 304 751 4.24 / 526.95 3 3
Average= 4.08
(KJ/cycle)

Cycle 127 GMT 26/ 6/2021 1:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 29 14.94 438 190 0.19 / 518.61 3 3
2 10 1005.64 2 14.96 1734 52 0.24 / 518.66 2 3
3 3 949.84 -1 15.35 1 0 0.05 / 518.66 2 3
4 12 1160.28 3 15.07 1929 87 0.33 / 518.75 2 3
5 7 2003.72 32 14.58 2965 1383 1.71 / 520.13 3 3
6 13 1517.20 27 14.61 2304 909 2.62 / 521.04 2 3
7 13 800.92 27 14.76 1412 563 3.18 / 521.61 2 3
8 13 132.00 27 14.98 511 207 3.39 / 521.81 2 3
9 13 29.56 27 15.01 352 143 3.53 / 521.96 3 3
10 8 0.08 165 14.98 306 756 4.29 / 522.71 3 5
Average= 4.08
(KJ/cycle)

Cycle 126 GMT 16/ 6/2021 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 29 14.94 441 191 0.19 / 514.36 3 3
2 12 1188.84 3 15.03 1951 88 0.28 / 514.44 2 3
3 7 2003.88 32 14.59 2939 1372 1.65 / 515.82 3 3
4 13 1527.84 27 14.61 2324 917 2.57 / 516.73 2 3
5 13 769.28 27 14.77 1344 536 3.10 / 517.27 2 2
6 13 199.36 27 14.94 613 247 3.35 / 517.52 2 3
7 13 40.36 27 14.99 367 149 3.50 / 517.66 2 3
8 8 0.08 165 14.97 307 758 4.26 / 518.42 3 4
Average= 4.08
(KJ/cycle)

Cycle 125 GMT 6/ 6/2021 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 29 14.95 446 193 0.19 / 510.07 3 3
2 12 1188.92 3 15.05 1960 88 0.28 / 510.16 2 2
3 7 2006.28 32 14.59 2938 1372 1.65 / 511.53 2 3
4 13 1523.96 27 14.61 2318 914 2.57 / 512.45 2 2
5 13 791.64 27 14.76 1389 554 3.12 / 513.00 2 2
6 13 224.84 27 14.93 650 262 3.38 / 513.26 2 2
7 13 22.60 27 15.00 339 137 3.52 / 513.40 2 3
8 8 0.04 165 14.97 309 763 4.28 / 514.16 3 5
Average= 4.08
(KJ/cycle)

Cycle 124 GMT 27/ 5/2021 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 29 14.95 438 190 0.19 / 505.86 3 3
2 12 1156.76 3 15.05 1905 86 0.28 / 505.95 2 3
3 7 2003.96 32 14.59 2944 1374 1.65 / 507.32 3 2
4 13 1503.56 27 14.63 2297 907 2.56 / 508.23 2 2
5 13 782.44 27 14.77 1382 551 3.11 / 508.78 2 3
6 13 142.24 27 14.98 522 211 3.32 / 508.99 2 3
7 13 34.68 27 15.01 356 144 3.46 / 509.13 3 3
8 8 -0.08 165 14.98 302 746 4.21 / 509.88 2 4
Average= 4.08
(KJ/cycle)

Cycle 123 GMT 17/ 5/2021 8:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 29 14.96 452 196 0.20 / 501.55 3 3
2 12 1181.84 3 15.04 1972 89 0.29 / 501.64 2 3
3 7 2005.20 32 14.59 2968 1386 1.67 / 503.03 3 3
4 13 1534.36 27 14.61 2330 919 2.59 / 503.94 2 2
5 13 809.76 27 14.75 1417 564 3.15 / 504.51 2 2
6 13 224.20 27 14.93 654 264 3.42 / 504.77 2 2
7 13 44.04 27 14.99 366 148 3.57 / 504.92 2 3
8 8 0.00 165 14.97 303 748 4.31 / 505.67 3 5
Average= 4.08
(KJ/cycle)

Cycle 122 GMT 7/ 5/2021 11: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 29 14.95 452 196 0.20 / 497.43 3 3
2 12 1178.04 3 15.05 1983 90 0.29 / 497.52 2 2
3 7 2002.72 32 14.60 2951 1379 1.66 / 498.90 2 3
4 13 1516.48 27 14.62 2310 912 2.58 / 499.81 2 2
5 13 771.40 27 14.77 1369 546 3.12 / 500.36 2 2
6 13 210.24 27 14.94 626 253 3.37 / 500.61 2 3
7 8 0.20 165 14.99 300 742 4.12 / 501.36 3 3
Average= 4.08
(KJ/cycle)

Cycle 121 GMT 27/ 4/2021 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 14.97 434 188 0.19 / 493.12 3 3
2 12 1171.56 3 15.05 1929 87 0.28 / 493.21 2 3
3 7 2002.96 32 14.60 2947 1377 1.65 / 494.58 3 3
4 13 1671.08 27 14.59 2506 987 2.64 / 495.57 2 2
5 13 742.28 27 14.78 1338 534 3.17 / 496.10 2 2
6 13 203.76 27 14.95 615 248 3.42 / 496.35 2 3
7 13 22.32 27 15.01 339 137 3.56 / 496.49 2 3
8 8 -0.04 165 14.98 303 749 4.31 / 497.24 3 5
Average= 4.08
(KJ/cycle)

Cycle 120 GMT 17/ 4/2021 14:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 14.97 453 197 0.20 / 488.98 3 3
2 12 1171.56 3 15.04 1970 89 0.29 / 489.07 2 2
3 7 2002.92 32 14.60 2946 1376 1.66 / 490.45 2 2
4 13 1512.72 27 14.62 2309 911 2.57 / 491.36 2 2
5 13 805.20 27 14.76 1408 561 3.13 / 491.92 2 3
6 13 223.76 27 14.94 645 260 3.39 / 492.18 2 3
7 8 0.24 165 14.99 303 749 4.14 / 492.93 3 5
Average= 4.07
(KJ/cycle)

Cycle 119 GMT 7/ 4/2021 16:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 29 14.95 465 202 0.20 / 484.92 3 3
2 12 1166.92 3 15.03 1975 89 0.29 / 485.01 2 2
3 7 2004.04 33 14.58 2957 1423 1.71 / 486.43 2 3
4 13 1507.64 27 14.62 2286 902 2.62 / 487.34 2 2
5 13 641.08 27 14.81 1203 481 3.10 / 487.82 2 2
6 13 156.84 27 14.97 539 218 3.31 / 488.03 2 2
7 8 0.08 165 15.00 304 752 4.07 / 488.79 3 6
Average= 4.07
(KJ/cycle)

Cycle 118 GMT 28/ 3/2021 18: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 29 14.95 465 202 0.20 / 480.82 3 3
2 12 1172.92 3 15.06 1929 87 0.29 / 480.91 2 2
3 7 2002.56 32 14.59 2941 1373 1.66 / 482.28 2 2
4 13 1481.12 27 14.63 2252 890 2.55 / 483.17 2 3
5 13 752.24 27 14.78 1345 537 3.09 / 483.71 2 3
6 13 194.36 27 14.95 609 246 3.33 / 483.96 2 2
7 8 0.00 165 14.99 309 764 4.10 / 484.72 3 4
Average= 4.07
(KJ/cycle)

Cycle 117 GMT 18/ 3/2021 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 29 14.97 453 197 0.20 / 476.26 3 3
2 12 1183.40 3 15.05 1971 89 0.29 / 476.35 2 3
3 7 2003.60 32 14.59 2946 1375 1.66 / 477.73 3 2
4 13 1518.84 27 14.62 2312 913 2.57 / 478.64 2 2
5 13 974.84 27 14.70 1621 643 3.22 / 479.28 2 2
6 13 195.40 27 14.95 610 246 3.46 / 479.53 2 3
7 8 0.00 165 14.99 304 752 4.22 / 480.28 3 6
8 14 0.00 75 14.95 302 339 4.55 / 480.62 3 8
Average= 4.07
(KJ/cycle)

Cycle 116 GMT 8/ 3/2021 21:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 29 14.97 447 194 0.19 / 472.08 3 3
2 12 1159.12 3 15.05 1952 88 0.28 / 472.17 2 3
3 7 2001.52 32 14.60 2945 1376 1.66 / 473.55 3 2
4 13 1679.36 27 14.58 2534 998 2.66 / 474.54 2 2
5 13 757.04 27 14.78 1340 535 3.19 / 475.08 2 2
6 13 199.72 27 14.95 613 247 3.44 / 475.32 2 3
7 8 0.12 165 15.00 300 742 4.18 / 476.07 3 3
Average= 4.07
(KJ/cycle)

Cycle 115 GMT 26/ 2/2021 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 14.97 450 195 0.20 / 467.93 3 3
2 12 1170.88 3 15.04 1953 88 0.28 / 468.02 2 3
3 7 2002.92 32 14.59 2965 1384 1.67 / 469.41 3 2
4 13 1506.44 27 14.62 2310 912 2.58 / 470.32 2 2
5 13 775.60 27 14.77 1381 551 3.13 / 470.87 2 3
6 13 216.16 27 14.94 647 261 3.39 / 471.13 2 2
7 8 0.00 165 14.99 306 757 4.15 / 471.89 3 3
Average= 4.07
(KJ/cycle)

Cycle 114 GMT 17/ 2/2021 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 14.96 452 196 0.20 / 463.93 3 3
2 12 1186.60 3 15.06 1959 89 0.28 / 464.02 2 2
3 7 2008.96 32 14.60 2945 1376 1.66 / 465.40 2 3
4 13 1507.12 27 14.61 2316 914 2.57 / 466.31 2 2
5 13 614.04 27 14.83 1166 467 3.04 / 466.78 2 2
6 13 166.20 27 14.97 548 221 3.26 / 467.00 2 3
7 8 0.12 165 15.00 298 738 4.00 / 467.74 3 3
Average= 4.07
(KJ/cycle)

Cycle 113 GMT 7/ 2/2021 2:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 29 14.96 455 197 0.20 / 459.70 3 3
2 12 1166.48 3 15.05 1951 88 0.29 / 459.79 2 2
3 7 2001.96 34 14.58 2954 1464 1.75 / 461.25 2 2
4 13 1493.44 28 14.62 2281 934 2.68 / 462.19 2 2
5 13 746.28 28 14.77 1348 557 3.24 / 462.75 2 2
6 13 178.76 28 14.96 577 242 3.48 / 462.99 2 3
7 8 0.12 165 14.99 304 752 4.23 / 463.74 3 5
Average= 4.07
(KJ/cycle)

Cycle 112 GMT 28/ 1/2021 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 29 14.97 436 189 0.19 / 455.41 3 3
2 12 1175.96 3 15.05 1971 89 0.28 / 455.50 2 3
3 7 2004.68 34 14.59 2944 1460 1.74 / 456.96 3 3
4 13 1663.56 28 14.58 2496 1019 2.76 / 457.98 2 2
5 13 719.44 28 14.79 1304 540 3.30 / 458.52 2 3
6 13 168.28 28 14.97 559 234 3.53 / 458.75 2 3
7 8 0.00 165 14.99 304 752 4.28 / 459.50 3 4
Average= 4.07
(KJ/cycle)

Cycle 111 GMT 18/ 1/2021 7: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 14.95 461 200 0.20 / 451.00 3 3
2 12 1171.32 2 15.07 1972 59 0.26 / 451.06 2 2
3 7 2003.16 34 14.59 2952 1464 1.72 / 452.53 2 3
4 13 1504.56 28 14.63 2275 932 2.66 / 453.46 2 3
5 13 611.40 28 14.83 1159 481 3.14 / 453.94 2 3
6 13 156.16 28 14.98 529 222 3.36 / 454.16 2 3
7 8 0.16 165 15.00 294 728 4.09 / 454.89 3 6
8 14 0.16 75 14.97 295 331 4.42 / 455.22 3 16
Average= 4.06
(KJ/cycle)

Cycle 110 GMT 8/ 1/2021 8:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 29 14.97 439 191 0.19 / 446.57 3 3
2 12 1172.48 2 15.08 1972 59 0.25 / 446.63 2 3
3 7 2004.96 34 14.59 2936 1456 1.71 / 448.09 3 2
4 13 1666.08 28 14.57 2512 1025 2.73 / 449.11 2 2
5 13 731.16 28 14.79 1310 542 3.27 / 449.65 2 2
6 13 183.08 28 14.96 584 245 3.52 / 449.90 2 3
7 13 37.72 28 15.01 355 149 3.67 / 450.05 2 3
8 8 0.04 165 14.98 305 754 4.42 / 450.80 3 4
Average= 4.06
(KJ/cycle)

Cycle 109 GMT 29/12/2020 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 29 14.96 462 200 0.20 / 442.37 3 3
2 12 1167.80 2 15.09 1950 59 0.26 / 442.43 2 2
3 7 2003.40 34 14.58 2950 1462 1.72 / 443.90 2 2
4 13 1504.16 28 14.62 2307 944 2.67 / 444.84 2 3
5 13 763.96 28 14.77 1348 557 3.22 / 445.40 2 2
6 13 196.52 28 14.95 600 251 3.47 / 445.65 2 3
7 8 0.12 165 14.99 296 732 4.21 / 446.38 3 3
Average= 4.06
(KJ/cycle)

Cycle 108 GMT 19/12/2020 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 29 14.98 442 192 0.19 / 438.17 3 3
2 12 1171.68 2 15.09 1937 58 0.25 / 438.23 2 3
3 7 2001.08 34 14.59 2955 1466 1.72 / 439.70 3 2
4 13 1497.48 28 14.63 2288 937 2.65 / 440.64 2 2
5 13 759.96 28 14.78 1351 559 3.21 / 441.20 2 3
6 13 193.16 28 14.95 595 249 3.46 / 441.44 2 3
7 8 0.08 165 15.00 295 730 4.19 / 442.17 3 4
Average= 4.06
(KJ/cycle)

Cycle 107 GMT 9/12/2020 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 29 14.98 433 188 0.19 / 434.11 3 3
2 7 2013.48 34 14.60 2961 1470 1.66 / 435.58 3 3
3 13 1547.96 21 14.63 2361 725 2.38 / 436.31 2 3
4 13 1047.44 21 14.71 1731 535 2.92 / 436.84 2 3
5 13 361.92 21 14.90 847 265 3.18 / 437.11 2 3
6 13 129.72 21 14.99 487 153 3.34 / 437.26 2 3
7 8 0.04 165 15.00 292 723 4.06 / 437.98 3 3
Average= 4.06
(KJ/cycle)

Cycle 106 GMT 29/11/2020 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 29 14.97 433 188 0.19 / 429.98 3 3
2 7 2003.44 35 14.60 2936 1500 1.69 / 431.48 2 3
3 13 1524.52 21 14.65 2324 715 2.40 / 432.19 2 3
4 13 1002.24 21 14.72 1672 517 2.92 / 432.71 2 2
5 13 304.92 21 14.92 766 240 3.16 / 432.95 2 2
6 13 112.56 21 15.00 469 148 3.31 / 433.10 3 3
7 13 25.44 21 15.02 332 105 3.41 / 433.20 2 3
8 8 0.20 165 15.00 292 723 4.14 / 433.92 3 5
Average= 4.06
(KJ/cycle)

Cycle 105 GMT 19/11/2020 19:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 29 14.97 448 194 0.19 / 425.87 3 3
2 7 2009.80 34 14.60 2941 1460 1.65 / 427.33 3 3
3 13 1674.08 21 14.62 2506 769 2.42 / 428.10 2 3
4 13 847.28 21 14.78 1450 450 2.87 / 428.55 2 2
5 13 356.84 21 14.91 835 261 3.14 / 428.81 2 3
6 13 117.84 21 15.00 474 149 3.28 / 428.96 2 3
7 13 30.84 21 15.02 334 105 3.39 / 429.07 3 3
8 8 0.12 165 15.00 291 720 4.11 / 429.79 3 5
Average= 4.05
(KJ/cycle)

Cycle 104 GMT 9/11/2020 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 29 14.96 426 185 0.18 / 421.69 3 3
2 7 2012.52 34 14.60 2970 1474 1.66 / 423.16 3 2
3 13 1690.84 21 14.62 2533 778 2.44 / 423.94 2 2
4 13 983.16 21 14.73 1636 506 2.94 / 424.45 2 2
5 13 326.00 21 14.92 790 248 3.19 / 424.69 2 3
6 13 104.60 21 15.00 463 146 3.34 / 424.84 2 3
7 13 27.20 21 15.02 341 108 3.44 / 424.95 3 3
8 8 0.04 165 15.00 295 730 4.17 / 425.68 3 3
Average= 4.05
(KJ/cycle)

Cycle 103 GMT 30/10/2020 23:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 29 14.97 449 195 0.19 / 417.50 3 3
2 7 2010.84 34 14.58 2949 1462 1.66 / 418.96 3 2
3 13 1685.24 21 14.61 2533 777 2.43 / 419.74 2 2
4 13 996.52 21 14.73 1651 511 2.94 / 420.25 2 3
5 13 349.52 21 14.91 832 261 3.21 / 420.51 2 2
6 13 115.20 21 14.99 474 149 3.35 / 420.66 2 3
7 13 61.84 21 15.00 383 121 3.48 / 420.78 2 3
8 8 0.20 165 14.99 293 725 4.20 / 421.50 3 5
Average= 4.05
(KJ/cycle)

Cycle 102 GMT 21/10/2020 1:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 29 14.97 435 189 0.19 / 413.21 3 3
2 7 2007.48 34 14.60 2947 1463 1.65 / 414.68 3 2
3 13 1685.24 21 14.61 2496 766 2.42 / 415.44 2 3
4 13 1136.24 21 14.69 1837 567 2.98 / 416.01 2 2
5 13 449.76 21 14.87 966 302 3.29 / 416.31 2 2
6 13 160.04 21 14.98 532 167 3.45 / 416.48 2 3
7 13 18.56 21 15.03 314 99 3.55 / 416.58 2 3
8 8 0.08 165 14.99 294 727 4.28 / 417.30 3 4
Average= 4.05
(KJ/cycle)

Cycle 101 GMT 11/10/2020 4: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 29 14.97 447 194 0.19 / 408.99 3 3
2 7 2005.28 34 14.61 2951 1466 1.66 / 410.46 3 3
3 13 1679.40 21 14.62 2510 771 2.43 / 411.23 2 2
4 13 979.16 21 14.75 1614 500 2.93 / 411.73 2 2
5 13 451.24 21 14.87 955 298 3.23 / 412.03 2 3
6 13 166.44 21 14.98 533 168 3.40 / 412.19 2 3
7 13 43.16 21 15.02 348 110 3.51 / 412.30 3 3
8 8 0.12 165 15.00 291 720 4.23 / 413.02 3 3
Average= 4.05
(KJ/cycle)

Cycle 100 GMT 1/10/2020 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 29 14.97 435 189 0.19 / 404.88 3 3
2 7 2005.44 34 14.60 2954 1466 1.66 / 406.35 3 2
3 13 1531.20 21 14.65 2346 722 2.38 / 407.07 2 3
4 13 889.20 21 14.77 1519 471 2.85 / 407.54 2 2
5 13 373.04 21 14.90 866 271 3.12 / 407.81 2 3
6 13 134.08 21 14.99 502 158 3.28 / 407.97 2 3
7 13 35.80 21 15.02 342 108 3.38 / 408.08 2 3
8 8 0.04 165 15.00 292 723 4.11 / 408.80 3 4
Average= 4.05
(KJ/cycle)

Cycle 99 GMT 21/ 9/2020 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 29 14.97 456 198 0.20 / 400.68 3 3
2 7 2008.24 34 14.61 2946 1463 1.66 / 402.14 3 2
3 13 1648.12 21 14.63 2476 761 2.42 / 402.90 2 2
4 13 973.72 21 14.74 1618 501 2.92 / 403.40 2 2
5 13 432.60 21 14.88 938 293 3.22 / 403.69 2 2
6 13 138.16 21 14.99 510 161 3.38 / 403.85 2 3
7 13 34.96 21 15.02 344 109 3.49 / 403.96 2 3
8 8 -0.08 165 15.00 294 728 4.21 / 404.69 3 8
Average= 4.05
(KJ/cycle)

Cycle 98 GMT 11/ 9/2020 10:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 29 14.96 461 200 0.20 / 396.52 3 3
2 7 2006.96 35 14.60 2943 1504 1.70 / 398.03 3 2
3 13 1535.32 21 14.65 2358 725 2.43 / 398.75 2 2
4 13 1019.48 21 14.72 1692 523 2.95 / 399.27 2 2
5 13 453.28 21 14.87 965 301 3.25 / 399.58 2 2
6 13 144.56 21 14.98 522 164 3.42 / 399.74 2 3
7 8 0.20 165 15.00 298 738 4.16 / 400.48 3 4
Average= 4.05
(KJ/cycle)

Cycle 97 GMT 1/ 9/2020 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 29 14.97 446 194 0.19 / 392.38 3 3
2 7 2005.20 35 14.60 2956 1511 1.70 / 393.89 3 3
3 13 1524.00 21 14.64 2335 718 2.42 / 394.61 2 3
4 13 855.72 21 14.78 1483 460 2.88 / 395.07 2 2
5 13 357.24 21 14.91 840 263 3.15 / 395.33 2 2
6 13 118.56 21 14.99 476 150 3.30 / 395.48 2 3
7 13 30.24 21 15.02 343 108 3.40 / 395.59 2 3
8 8 0.12 165 15.00 295 730 4.13 / 396.32 3 5
Average= 4.04
(KJ/cycle)

Cycle 96 GMT 22/ 8/2020 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 29 14.98 447 194 0.19 / 388.39 3 3
2 7 2007.24 34 14.61 2941 1461 1.66 / 389.85 3 2
3 13 1524.52 21 14.66 2330 717 2.37 / 390.57 2 2
4 13 866.12 21 14.78 1489 462 2.83 / 391.03 2 2
5 13 372.44 21 14.90 861 269 3.10 / 391.30 2 3
6 13 117.72 21 14.99 484 152 3.26 / 391.45 2 2
7 8 0.16 165 15.00 299 740 4.00 / 392.19 3 3
Average= 4.04
(KJ/cycle)

Cycle 95 GMT 12/ 8/2020 17: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 14.97 438 190 0.19 / 384.24 3 3
2 7 2002.60 34 14.61 2942 1461 1.65 / 385.70 3 2
3 13 1681.60 21 14.63 2515 773 2.42 / 386.47 2 2
4 13 982.20 21 14.75 1635 506 2.93 / 386.98 2 2
5 13 313.08 21 14.93 775 243 3.17 / 387.22 2 3
6 13 112.00 21 15.01 463 146 3.32 / 387.37 2 3
7 13 28.64 21 15.03 335 106 3.43 / 387.47 3 3
8 8 0.04 165 15.01 291 721 4.15 / 388.19 3 4
Average= 4.04
(KJ/cycle)

Cycle 94 GMT 2/ 8/2020 19:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 28 14.98 447 187 0.19 / 380.15 3 3
2 7 2008.80 34 14.61 2955 1468 1.66 / 381.61 3 2
3 13 1521.80 21 14.65 2321 714 2.37 / 382.33 2 2
4 13 866.12 21 14.77 1499 465 2.83 / 382.79 2 2
5 13 363.12 21 14.91 843 264 3.10 / 383.06 2 2
6 13 106.92 21 15.00 467 147 3.25 / 383.20 2 3
7 13 27.60 21 15.02 341 108 3.35 / 383.31 2 3
8 8 0.16 165 15.00 297 735 4.09 / 384.05 3 4
Average= 4.04
(KJ/cycle)

Cycle 93 GMT 23/ 7/2020 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 28 14.98 436 183 0.18 / 376.14 3 3
2 7 2005.80 34 14.61 2956 1468 1.65 / 377.60 3 3
3 13 1536.88 21 14.66 2359 726 2.38 / 378.33 2 3
4 13 862.44 21 14.78 1493 463 2.84 / 378.79 2 2
5 13 359.56 21 14.91 843 264 3.10 / 379.06 2 3
6 13 117.24 21 15.00 487 153 3.26 / 379.21 2 3
7 8 0.08 165 15.01 302 748 4.01 / 379.96 3 5
Average= 4.04
(KJ/cycle)

Cycle 92 GMT 13/ 7/2020 23:34:29

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 28 14.97 450 189 0.19 / 372.08 3 3
2 7 2006.04 34 14.61 2958 1469 1.66 / 373.54 3 3
3 13 1531.76 21 14.67 2312 712 2.37 / 374.26 2 2
4 13 1012.36 21 14.74 1663 515 2.89 / 374.77 2 2
5 13 457.84 21 14.88 968 302 3.19 / 375.07 2 2
6 13 95.28 21 15.01 445 140 3.33 / 375.21 2 3
7 8 0.16 165 15.01 298 738 4.07 / 375.95 3 4
Average= 4.04
(KJ/cycle)

Cycle 91 GMT 4/ 7/2020 1:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 29 14.98 444 193 0.19 / 368.04 3 3
2 7 2004.16 34 14.61 2948 1464 1.66 / 369.51 3 2
3 13 1536.80 21 14.65 2342 721 2.38 / 370.23 2 2
4 13 1003.52 21 14.74 1672 518 2.90 / 370.75 2 2
5 13 328.56 21 14.93 799 251 3.15 / 371.00 2 3
6 13 102.00 21 15.01 455 143 3.29 / 371.14 2 3
7 8 0.08 165 15.01 301 745 4.03 / 371.89 3 4
Average= 4.04
(KJ/cycle)

Cycle 90 GMT 24/ 6/2020 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 14.99 443 193 0.19 / 364.04 3 3
2 7 2003.76 34 14.62 2949 1466 1.66 / 365.50 3 2
3 13 1526.96 21 14.66 2329 717 2.38 / 366.22 2 2
4 13 870.00 21 14.78 1499 465 2.84 / 366.69 2 3
5 13 362.56 21 14.91 854 267 3.11 / 366.95 2 2
6 13 105.52 21 15.00 468 147 3.26 / 367.10 2 3
7 8 0.04 165 15.01 303 750 4.01 / 367.85 3 3
Average= 4.04
(KJ/cycle)

Cycle 89 GMT 14/ 6/2020 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 29 14.98 438 190 0.19 / 360.00 3 3
2 7 2003.24 35 14.61 2950 1508 1.70 / 361.51 3 2
3 13 1493.92 21 14.67 2309 711 2.41 / 362.22 2 3
4 13 966.36 21 14.75 1626 504 2.91 / 362.72 2 3
5 13 288.16 21 14.95 750 235 3.15 / 362.96 2 2
6 13 97.36 21 15.02 450 142 3.29 / 363.10 2 3
7 8 0.16 165 15.02 302 748 4.04 / 363.85 3 6
Average= 4.04
(KJ/cycle)

Cycle 88 GMT 4/ 6/2020 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 29 14.98 452 196 0.20 / 355.97 3 3
2 7 2009.40 34 14.62 2938 1460 1.66 / 357.43 3 2
3 13 1529.52 21 14.67 2316 713 2.37 / 358.14 2 3
4 13 1001.36 21 14.75 1655 513 2.88 / 358.65 2 2
5 13 316.52 21 14.94 784 246 3.13 / 358.90 2 2
6 13 101.72 21 15.02 457 144 3.27 / 359.04 2 3
7 8 0.16 165 15.01 308 763 4.04 / 359.81 3 4
Average= 4.04
(KJ/cycle)

Cycle 87 GMT 25/ 5/2020 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 29 14.99 450 196 0.20 / 351.90 3 3
2 7 2006.84 34 14.62 2959 1471 1.67 / 353.37 3 3
3 13 1541.12 21 14.65 2347 722 2.39 / 354.09 2 2
4 13 1031.68 21 14.74 1706 528 2.92 / 354.62 2 2
5 13 340.44 21 14.93 827 259 3.18 / 354.88 2 2
6 13 117.48 21 15.01 481 152 3.33 / 355.03 2 3
7 8 0.08 165 15.02 300 743 4.07 / 355.77 3 3
Average= 4.04
(KJ/cycle)

Cycle 86 GMT 15/ 5/2020 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 29 14.99 453 197 0.20 / 347.76 3 3
2 7 2003.00 34 14.62 2949 1466 1.66 / 349.22 3 3
3 13 1666.68 21 14.64 2517 774 2.44 / 349.99 2 2
4 13 970.12 21 14.76 1615 501 2.94 / 350.50 2 2
5 13 435.44 21 14.90 942 295 3.23 / 350.79 2 2
6 13 149.88 21 15.00 527 166 3.40 / 350.96 2 3
7 8 0.04 165 15.02 300 743 4.14 / 351.70 3 5
Average= 4.04
(KJ/cycle)

Cycle 85 GMT 5/ 5/2020 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 29 15.00 445 194 0.19 / 343.69 3 3
2 7 2004.00 34 14.63 2944 1464 1.66 / 345.16 3 3
3 13 1689.52 21 14.64 2567 789 2.45 / 345.95 2 2
4 13 840.84 21 14.80 1465 455 2.90 / 346.40 2 2
5 13 349.80 21 14.93 833 261 3.16 / 346.66 2 2
6 13 126.44 21 15.02 492 155 3.32 / 346.82 2 3
7 8 0.20 165 15.03 298 739 4.06 / 347.56 3 4
Average= 4.04
(KJ/cycle)

Cycle 84 GMT 25/ 4/2020 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 29 14.99 449 195 0.20 / 339.65 3 3
2 7 2015.96 35 14.62 2973 1521 1.72 / 341.17 3 3
3 13 1538.68 21 14.67 2342 721 2.44 / 341.89 2 2
4 13 864.16 21 14.79 1489 462 2.90 / 342.35 2 2
5 13 344.52 21 14.93 823 258 3.16 / 342.61 2 2
6 13 123.92 21 15.02 486 153 3.31 / 342.76 2 3
7 8 0.08 165 15.03 297 737 4.05 / 343.50 3 7
Average= 4.04
(KJ/cycle)

Cycle 83 GMT 15/ 4/2020 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 28 14.99 452 190 0.19 / 335.63 3 3
2 3 1019.52 1 15.11 1778 27 0.22 / 335.65 2 3
3 7 2011.24 34 14.62 2953 1468 1.68 / 337.12 3 3
4 13 1521.00 21 14.68 2318 715 2.40 / 337.84 2 3
5 13 845.24 21 14.81 1467 456 2.86 / 338.29 2 2
6 13 353.80 21 14.94 834 262 3.12 / 338.55 2 2
7 13 120.16 21 15.02 481 152 3.27 / 338.71 2 3
8 8 0.16 165 15.03 301 746 4.02 / 339.45 3 3
Average= 4.04
(KJ/cycle)

Cycle 82 GMT 5/ 4/2020 20:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 14.99 454 191 0.19 / 331.52 3 3
2 7 2004.00 34 14.63 2961 1473 1.66 / 332.99 2 3
3 13 1672.96 21 14.64 2525 776 2.44 / 333.77 2 2
4 13 963.60 21 14.77 1620 502 2.94 / 334.27 2 2
5 13 298.08 21 14.96 761 239 3.18 / 334.51 2 3
6 13 154.88 21 15.01 540 170 3.35 / 334.68 2 2
7 8 0.04 165 15.03 305 756 4.11 / 335.44 3 4
Average= 4.04
(KJ/cycle)

Cycle 81 GMT 26/ 3/2020 22:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 28 15.00 449 189 0.19 / 327.51 3 3
2 7 2006.28 34 14.63 2962 1473 1.66 / 328.99 3 3
3 13 1403.00 21 14.70 2172 670 2.33 / 329.66 2 2
4 13 894.68 21 14.79 1539 478 2.81 / 330.13 2 2
5 13 384.52 21 14.93 883 277 3.09 / 330.41 2 3
6 13 129.76 21 15.01 502 158 3.25 / 330.57 2 3
7 8 0.20 165 15.03 306 759 4.00 / 331.33 3 4
Average= 4.04
(KJ/cycle)

Cycle 80 GMT 17/ 3/2020 0:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 28 15.00 448 188 0.19 / 323.48 3 3
2 7 2012.16 34 14.64 2931 1459 1.65 / 324.94 3 3
3 13 1515.40 21 14.69 2329 718 2.37 / 325.65 2 2
4 13 992.88 21 14.78 1644 510 2.88 / 326.16 2 2
5 13 315.64 21 14.96 787 247 3.12 / 326.41 2 3
6 13 99.72 21 15.04 464 147 3.27 / 326.56 2 3
7 8 0.00 165 15.03 309 766 4.04 / 327.32 3 3
Average= 4.04
(KJ/cycle)

Cycle 79 GMT 7/ 3/2020 2:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 15.03 438 184 0.18 / 319.39 3 3
2 7 2012.28 35 14.62 2962 1516 1.70 / 320.91 3 2
3 13 1528.64 21 14.68 2346 723 2.42 / 321.63 2 2
4 13 993.48 21 14.77 1647 511 2.93 / 322.14 2 2
5 13 303.72 21 14.96 766 241 3.17 / 322.38 2 3
6 13 98.72 21 15.04 461 146 3.32 / 322.53 2 3
7 8 0.00 165 15.03 307 761 4.08 / 323.29 3 6
Average= 4.04
(KJ/cycle)

Cycle 78 GMT 26/ 2/2020 5: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 28 15.02 450 189 0.19 / 315.32 3 3
2 7 2004.48 34 14.64 2949 1468 1.66 / 316.79 3 2
3 13 1677.56 21 14.66 2523 777 2.43 / 317.57 2 2
4 13 963.32 21 14.78 1619 503 2.94 / 318.07 2 3
5 13 298.16 21 14.97 763 240 3.18 / 318.31 2 2
6 13 132.28 21 15.04 497 157 3.33 / 318.47 2 3
7 8 0.12 165 15.05 298 740 4.07 / 319.21 3 3
Average= 4.04
(KJ/cycle)

Cycle 77 GMT 16/ 2/2020 7:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 28 14.99 440 185 0.18 / 311.28 3 3
2 7 2003.68 34 14.64 2949 1468 1.65 / 312.75 3 2
3 13 1508.96 21 14.69 2328 718 2.37 / 313.46 2 2
4 13 981.40 21 14.79 1649 512 2.88 / 313.98 2 2
5 13 308.04 21 14.98 782 246 3.13 / 314.22 2 2
6 13 129.24 21 15.05 493 156 3.28 / 314.38 2 3
7 8 0.20 165 15.05 304 755 4.04 / 315.13 3 4
Average= 4.04
(KJ/cycle)

Cycle 76 GMT 6/ 2/2020 9: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 15.02 447 188 0.19 / 306.66 3 3
2 3 1018.16 1 15.14 1744 26 0.21 / 306.69 2 2
3 7 2003.20 34 14.64 2937 1462 1.68 / 308.15 2 3
4 13 1661.20 21 14.67 2508 773 2.45 / 308.92 2 3
5 13 976.32 21 14.79 1639 509 2.96 / 309.43 2 2
6 13 432.96 21 14.93 940 295 3.25 / 309.73 2 2
7 13 119.24 21 15.04 494 156 3.41 / 309.88 2 3
8 13 29.12 21 15.07 355 112 3.52 / 309.99 2 3
9 8 0.00 165 15.04 307 762 4.28 / 310.76 3 5
10 14 0.00 75 15.00 301 339 4.62 / 311.09 3 30
Average= 4.04
(KJ/cycle)

Cycle 75 GMT 27/ 1/2020 11:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 15.02 453 191 0.19 / 302.48 3 3
2 7 2007.24 34 14.64 2963 1475 1.67 / 303.96 3 3
3 13 1533.64 21 14.68 2365 729 2.39 / 304.68 2 2
4 13 1023.48 21 14.77 1696 526 2.92 / 305.21 2 2
5 13 333.60 21 14.96 817 257 3.18 / 305.47 2 2
6 13 94.08 21 15.06 452 143 3.32 / 305.61 2 3
7 13 24.64 21 15.07 347 110 3.43 / 305.72 2 3
8 8 0.16 165 15.05 303 752 4.18 / 306.47 3 4
Average= 4.03
(KJ/cycle)

Cycle 74 GMT 17/ 1/2020 13:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 28 15.04 447 188 0.19 / 298.44 3 3
2 7 2009.56 34 14.64 2949 1468 1.66 / 299.90 3 3
3 13 1521.96 21 14.69 2313 714 2.37 / 300.62 2 3
4 13 1002.56 21 14.78 1677 521 2.89 / 301.14 2 2
5 13 317.04 21 14.98 795 250 3.14 / 301.39 2 2
6 13 93.40 21 15.06 459 145 3.29 / 301.53 2 3
7 8 0.04 165 15.06 305 758 4.04 / 302.29 3 4
Average= 4.03
(KJ/cycle)

Cycle 73 GMT 7/ 1/2020 15:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 28 15.03 450 189 0.19 / 294.40 3 3
2 7 2003.04 34 14.64 2948 1467 1.66 / 295.87 3 2
3 13 1519.96 21 14.70 2326 718 2.37 / 296.58 2 2
4 13 994.20 21 14.78 1654 513 2.89 / 297.10 2 2
5 13 298.28 21 14.99 769 242 3.13 / 297.34 2 3
6 13 88.92 21 15.07 446 141 3.27 / 297.48 2 3
7 8 0.12 165 15.07 308 766 4.04 / 298.25 3 4
Average= 4.03
(KJ/cycle)

Cycle 72 GMT 28/12/2019 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 28 15.04 443 187 0.19 / 290.13 3 3
2 7 2007.56 34 14.64 2936 1461 1.65 / 291.59 3 2
3 13 1665.88 21 14.67 2523 777 2.43 / 292.37 2 3
4 13 1093.16 21 14.76 1785 553 2.98 / 292.92 2 3
5 13 362.64 21 14.97 853 268 3.25 / 293.19 2 3
6 13 108.00 21 15.07 479 152 3.40 / 293.34 2 3
7 13 29.20 21 15.09 354 112 3.51 / 293.45 2 3
8 8 -0.12 165 15.06 305 758 4.27 / 294.21 3 4
Average= 4.03
(KJ/cycle)

Cycle 71 GMT 18/12/2019 20: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 28 15.04 443 187 0.19 / 285.98 3 3
2 7 2009.24 34 14.64 2946 1466 1.65 / 287.45 2 2
3 13 1677.28 21 14.67 2537 782 2.43 / 288.23 2 2
4 13 958.68 21 14.81 1606 499 2.93 / 288.73 2 2
5 13 421.80 21 14.96 924 290 3.22 / 289.02 2 3
6 13 118.36 21 15.06 496 157 3.38 / 289.18 2 3
7 8 0.16 165 15.07 308 766 4.15 / 289.94 3 4
Average= 4.03
(KJ/cycle)

Cycle 70 GMT 8/12/2019 22: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.06 439 185 0.19 / 281.91 3 3
2 7 2011.56 34 14.64 2964 1475 1.66 / 283.39 3 2
3 13 1530.20 21 14.69 2340 722 2.38 / 284.11 2 2
4 13 1012.44 21 14.79 1687 524 2.91 / 284.63 2 2
5 13 324.52 21 14.99 806 254 3.16 / 284.89 2 3
6 13 93.40 21 15.07 457 145 3.30 / 285.03 2 3
7 8 0.08 165 15.07 306 761 4.07 / 285.79 3 4
Average= 4.03
(KJ/cycle)

Cycle 69 GMT 29/11/2019 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 28 15.05 438 185 0.18 / 277.86 3 3
2 7 2003.68 35 14.64 2950 1512 1.70 / 279.37 3 2
3 13 1519.76 21 14.70 2314 714 2.41 / 280.09 2 2
4 13 971.44 21 14.81 1623 505 2.92 / 280.59 2 2
5 13 294.24 21 15.01 756 238 3.15 / 280.83 2 3
6 13 88.12 21 15.09 443 140 3.29 / 280.97 2 3
7 8 0.12 165 15.08 304 756 4.05 / 281.73 3 5
Average= 4.02
(KJ/cycle)

Cycle 68 GMT 19/11/2019 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 28 15.05 450 190 0.19 / 273.58 3 3
2 7 2007.16 35 14.65 2954 1515 1.70 / 275.10 3 3
3 13 1686.52 21 14.67 2539 782 2.49 / 275.88 2 3
4 13 929.32 21 14.82 1583 493 2.98 / 276.37 2 2
5 13 395.04 21 14.98 895 282 3.26 / 276.66 2 3
6 13 112.60 21 15.07 482 153 3.41 / 276.81 2 3
7 13 25.84 21 15.10 345 109 3.52 / 276.92 2 3
8 8 0.04 165 15.07 306 761 4.28 / 277.68 3 4
Average= 4.02
(KJ/cycle)

Cycle 67 GMT 9/11/2019 4:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 28 15.06 438 185 0.18 / 269.33 3 3
2 7 2005.68 34 14.66 2947 1469 1.65 / 270.80 2 3
3 13 1662.36 21 14.67 2520 776 2.43 / 271.58 2 2
4 13 943.72 21 14.83 1597 497 2.93 / 272.08 2 2
5 13 410.96 21 14.98 921 290 3.22 / 272.37 2 2
6 13 130.84 21 15.07 508 161 3.38 / 272.53 2 3
7 13 30.36 21 15.11 348 110 3.49 / 272.64 3 3
8 8 0.04 165 15.08 304 756 4.24 / 273.39 3 5
Average= 4.02
(KJ/cycle)

Cycle 66 GMT 30/10/2019 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 15.07 451 190 0.19 / 265.25 3 3
2 7 2003.88 34 14.66 2939 1465 1.66 / 266.71 3 2
3 13 1520.36 21 14.71 2329 719 2.37 / 267.43 2 2
4 13 839.48 21 14.86 1460 456 2.83 / 267.89 2 2
5 13 323.08 21 15.01 799 252 3.08 / 268.14 2 3
6 13 109.84 21 15.10 471 149 3.23 / 268.29 2 3
7 13 28.20 21 15.11 343 109 3.34 / 268.40 2 3
8 8 0.12 165 15.09 302 752 4.09 / 269.15 3 3
Average= 4.02
(KJ/cycle)

Cycle 65 GMT 20/10/2019 8:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 28 15.07 445 188 0.19 / 261.12 3 3
2 7 2012.20 34 14.65 2966 1477 1.67 / 262.60 2 3
3 13 1521.64 21 14.71 2332 720 2.39 / 263.32 2 3
4 13 864.68 21 14.86 1493 466 2.85 / 263.79 2 3
5 13 351.64 21 15.00 845 266 3.12 / 264.05 2 3
6 13 107.64 21 15.10 467 148 3.27 / 264.20 2 3
7 13 26.24 21 15.12 345 110 3.38 / 264.31 3 3
8 8 0.16 165 15.09 300 747 4.12 / 265.06 3 4
Average= 4.02
(KJ/cycle)

Cycle 64 GMT 10/10/2019 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 28 15.07 447 189 0.19 / 256.89 3 3
2 7 2005.08 34 14.65 2950 1469 1.66 / 258.36 3 2
3 13 1671.24 21 14.69 2480 765 2.42 / 259.13 2 2
4 13 946.64 21 14.84 1602 499 2.92 / 259.63 2 2
5 13 407.36 21 14.99 908 286 3.21 / 259.91 2 3
6 13 120.64 21 15.09 497 157 3.37 / 260.07 2 3
7 13 33.48 21 15.12 356 113 3.48 / 260.18 2 3
8 8 -0.04 165 15.09 302 752 4.23 / 260.94 3 4
Average= 4.01
(KJ/cycle)

Cycle 63 GMT 30/ 9/2019 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 28 15.07 450 190 0.19 / 252.77 3 3
2 7 2009.04 34 14.66 2951 1471 1.66 / 254.24 2 2
3 13 1512.88 21 14.73 2325 719 2.38 / 254.96 2 3
4 13 831.00 21 14.88 1456 455 2.83 / 255.41 2 2
5 13 325.12 21 15.02 811 256 3.09 / 255.67 2 2
6 13 108.80 21 15.10 481 153 3.24 / 255.82 2 3
7 13 58.00 21 15.12 396 126 3.37 / 255.95 2 3
8 8 0.16 165 15.10 305 760 4.13 / 256.71 3 4
Average= 4.01
(KJ/cycle)

Cycle 62 GMT 20/ 9/2019 14:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 28 15.08 438 185 0.18 / 248.56 3 3
2 7 2004.64 34 14.67 2907 1450 1.63 / 250.01 3 2
3 13 1515.00 21 14.72 2317 716 2.35 / 250.72 2 2
4 13 975.32 21 14.83 1642 511 2.86 / 251.23 2 2
5 13 421.32 21 14.99 930 293 3.16 / 251.53 2 2
6 13 120.64 21 15.09 509 161 3.32 / 251.69 2 2
7 13 32.44 21 15.12 364 116 3.43 / 251.80 2 3
8 8 0.00 165 15.10 310 772 4.20 / 252.58 3 4
Average= 4.01
(KJ/cycle)

Cycle 61 GMT 10/ 9/2019 17: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 28 15.07 435 184 0.18 / 244.41 3 3
2 7 2003.48 34 14.67 2934 1463 1.65 / 245.87 3 2
3 13 1682.28 21 14.69 2543 784 2.43 / 246.65 2 2
4 13 819.44 21 14.89 1427 446 2.88 / 247.10 2 2
5 13 324.16 21 15.03 809 255 3.13 / 247.36 2 2
6 13 96.68 21 15.12 461 146 3.28 / 247.50 2 2
7 13 25.40 21 15.14 349 111 3.39 / 247.61 2 3
8 8 0.00 165 15.11 304 758 4.15 / 248.37 3 4
Average= 4.01
(KJ/cycle)

Cycle 60 GMT 31/ 8/2019 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 28 15.09 441 186 0.19 / 239.95 3 3
2 7 2003.28 34 14.67 2935 1464 1.65 / 241.42 3 3
3 13 1522.28 21 14.73 2334 722 2.37 / 242.14 2 2
4 13 878.76 21 14.88 1506 471 2.84 / 242.61 2 2
5 13 359.36 21 15.03 853 269 3.11 / 242.88 2 3
6 13 101.80 21 15.11 470 149 3.26 / 243.03 2 3
7 13 27.64 21 15.13 348 111 3.37 / 243.14 2 3
8 8 0.04 165 15.11 302 753 4.12 / 243.89 3 5
9 14 0.04 75 15.08 295 334 4.46 / 244.22 3 47
Average= 4.00
(KJ/cycle)

Cycle 59 GMT 21/ 8/2019 21: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 28 15.10 449 190 0.19 / 235.80 3 3
2 7 2010.32 35 14.66 2933 1505 1.69 / 237.30 3 3
3 13 1519.60 21 14.74 2308 714 2.41 / 238.01 2 2
4 13 991.36 21 14.84 1655 516 2.92 / 238.53 2 2
5 13 287.64 21 15.05 759 240 3.16 / 238.77 2 2
6 13 95.20 21 15.13 448 142 3.31 / 238.91 2 3
7 13 23.40 21 15.15 334 106 3.41 / 239.02 2 3
8 8 0.12 165 15.12 299 746 4.16 / 239.77 3 3
Average= 4.00
(KJ/cycle)

Cycle 58 GMT 11/ 8/2019 23:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 28 15.10 444 188 0.19 / 231.76 3 3
2 7 2012.20 35 14.67 2940 1510 1.70 / 233.27 3 2
3 13 1515.52 21 14.74 2321 718 2.42 / 233.99 2 2
4 13 858.96 21 14.89 1487 465 2.88 / 234.45 2 2
5 13 319.60 21 15.04 804 254 3.13 / 234.71 2 2
6 13 94.44 21 15.13 452 144 3.28 / 234.85 2 3
7 8 0.08 165 15.13 302 754 4.03 / 235.61 3 5
Average= 3.99
(KJ/cycle)

Cycle 57 GMT 2/ 8/2019 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 28 15.10 445 188 0.19 / 227.53 3 3
2 7 2003.96 34 14.67 2949 1471 1.66 / 229.00 3 2
3 13 1668.60 21 14.71 2495 771 2.43 / 229.77 2 2
4 13 941.52 21 14.87 1593 497 2.93 / 230.27 2 2
5 13 387.12 21 15.03 888 280 3.21 / 230.55 2 2
6 13 112.40 21 15.12 487 155 3.36 / 230.70 2 3
7 13 27.40 21 15.15 347 110 3.47 / 230.81 2 3
8 8 0.00 165 15.12 305 761 4.23 / 231.57 3 5
Average= 3.99
(KJ/cycle)

Cycle 56 GMT 23/ 7/2019 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 28 15.10 449 190 0.19 / 223.53 3 3
2 7 2006.96 34 14.68 2944 1469 1.66 / 225.00 3 3
3 13 1514.84 21 14.75 2327 721 2.38 / 225.72 2 3
4 13 853.48 21 14.90 1483 464 2.84 / 226.18 2 2
5 13 337.40 21 15.05 826 261 3.11 / 226.44 2 2
6 13 94.24 21 15.14 455 145 3.25 / 226.59 2 3
7 8 0.04 165 15.14 302 754 4.00 / 227.34 3 3
Average= 3.99
(KJ/cycle)

Cycle 55 GMT 13/ 7/2019 5:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 28 15.11 444 188 0.19 / 219.52 3 3
2 7 2005.48 34 14.68 2923 1459 1.65 / 220.97 3 2
3 13 1394.36 21 14.78 2171 674 2.32 / 221.65 2 2
4 13 914.96 21 14.88 1575 492 2.81 / 222.14 2 2
5 13 378.04 21 15.03 875 276 3.09 / 222.42 2 2
6 13 108.20 21 15.13 478 152 3.24 / 222.57 2 3
7 8 0.08 165 15.14 307 767 4.01 / 223.34 3 4
Average= 3.99
(KJ/cycle)

Cycle 54 GMT 3/ 7/2019 7:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 28 15.11 443 187 0.19 / 215.47 3 3
2 7 2005.92 35 14.68 2925 1503 1.69 / 216.97 3 2
3 13 1528.04 21 14.74 2347 726 2.42 / 217.70 2 2
4 13 843.84 21 14.91 1476 462 2.88 / 218.16 2 2
5 13 328.08 21 15.06 808 256 3.13 / 218.42 2 2
6 13 92.52 21 15.14 456 145 3.28 / 218.56 2 3
7 8 0.12 165 15.14 306 764 4.04 / 219.33 3 4
Average= 3.99
(KJ/cycle)

Cycle 53 GMT 23/ 6/2019 8:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 28 15.11 455 193 0.19 / 211.48 3 3
2 7 2008.64 34 14.68 2963 1479 1.67 / 212.96 3 2
3 13 1358.44 21 14.80 2131 662 2.33 / 213.63 2 3
4 13 874.60 21 14.91 1512 473 2.81 / 214.10 2 3
5 13 338.56 21 15.06 834 264 3.07 / 214.36 2 3
6 13 92.00 21 15.15 455 145 3.22 / 214.51 2 3
7 8 0.20 165 15.14 311 777 3.99 / 215.28 3 4
Average= 3.99
(KJ/cycle)

Cycle 52 GMT 13/ 6/2019 11: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 15.12 442 187 0.19 / 207.43 3 3
2 7 2003.92 34 14.69 2933 1465 1.65 / 208.89 3 2
3 13 1506.80 21 14.76 2327 721 2.37 / 209.61 2 2
4 13 986.28 21 14.88 1656 517 2.89 / 210.13 2 3
5 13 306.60 21 15.08 777 246 3.14 / 210.38 2 3
6 13 91.92 21 15.15 451 143 3.28 / 210.52 2 3
7 8 0.12 165 15.15 309 772 4.05 / 211.29 3 5
Average= 3.99
(KJ/cycle)

Cycle 51 GMT 3/ 6/2019 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 27 15.12 455 186 0.19 / 203.42 3 3
2 7 2007.64 34 14.68 2962 1478 1.66 / 204.90 2 2
3 13 1524.48 21 14.76 2336 724 2.39 / 205.63 2 2
4 13 832.32 21 14.93 1445 453 2.84 / 206.08 2 2
5 13 309.12 21 15.08 787 249 3.09 / 206.33 2 2
6 13 83.24 21 15.16 444 141 3.23 / 206.47 2 3
7 8 0.00 165 15.15 308 770 4.00 / 207.24 3 3
Average= 3.99
(KJ/cycle)

Cycle 50 GMT 24/ 5/2019 15: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 15.12 445 182 0.18 / 199.35 3 3
2 7 2009.52 34 14.70 2925 1462 1.64 / 200.81 2 2
3 13 1692.32 21 14.72 2544 786 2.43 / 201.60 2 2
4 13 833.44 21 14.93 1459 457 2.89 / 202.05 2 2
5 13 330.52 21 15.08 818 259 3.15 / 202.31 2 2
6 13 97.28 21 15.16 458 146 3.29 / 202.46 2 3
7 8 0.12 165 15.15 311 777 4.07 / 203.24 3 3
Average= 3.99
(KJ/cycle)

Cycle 49 GMT 14/ 5/2019 17: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 27 15.13 471 192 0.19 / 195.27 3 3
2 7 2007.80 34 14.69 2951 1474 1.67 / 196.75 3 2
3 13 1669.36 21 14.73 2528 782 2.45 / 197.53 2 2
4 13 958.32 21 14.89 1615 505 2.95 / 198.04 2 2
5 13 265.40 21 15.10 729 231 3.18 / 198.27 2 2
6 13 81.56 21 15.17 433 138 3.32 / 198.40 2 3
7 8 0.04 165 15.16 305 763 4.09 / 199.17 3 4
Average= 3.98
(KJ/cycle)

Cycle 48 GMT 4/ 5/2019 19: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 27 15.13 451 184 0.18 / 191.23 3 3
2 7 2005.92 34 14.70 2957 1478 1.66 / 192.70 3 2
3 13 1506.96 21 14.77 2321 720 2.38 / 193.42 2 2
4 13 973.96 21 14.89 1634 511 2.89 / 193.93 2 2
5 13 270.56 21 15.10 736 233 3.13 / 194.17 2 2
6 13 88.12 21 15.17 445 142 3.27 / 194.31 2 3
7 8 0.04 165 15.16 309 773 4.04 / 195.08 2 4
Average= 3.98
(KJ/cycle)

Cycle 47 GMT 24/ 4/2019 21:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 27 15.13 461 188 0.19 / 187.17 3 3
2 7 2018.04 34 14.70 2951 1475 1.66 / 188.64 3 2
3 13 1524.52 21 14.77 2333 724 2.39 / 189.37 2 2
4 13 995.84 21 14.88 1655 517 2.90 / 189.88 2 3
5 13 276.32 21 15.10 739 234 3.14 / 190.12 2 2
6 13 88.52 21 15.17 445 142 3.28 / 190.26 2 3
7 8 0.04 165 15.16 312 780 4.06 / 191.04 3 3
Average= 3.98
(KJ/cycle)

Cycle 46 GMT 14/ 4/2019 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 27 15.14 449 184 0.18 / 183.07 3 3
2 3 1018.68 1 15.18 1773 27 0.21 / 183.10 2 2
3 7 2012.16 34 14.70 2947 1473 1.68 / 184.57 2 2
4 13 1504.12 21 14.78 2326 722 2.41 / 185.29 2 2
5 13 988.12 21 14.89 1660 519 2.92 / 185.81 2 3
6 13 289.56 21 15.10 769 244 3.17 / 186.06 2 3
7 13 88.24 21 15.18 450 143 3.31 / 186.20 2 2
8 8 0.12 165 15.17 312 781 4.09 / 186.98 2 3
Average= 3.98
(KJ/cycle)

Cycle 45 GMT 5/ 4/2019 1:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 27 15.14 464 190 0.19 / 178.95 3 3
2 7 2006.64 34 14.71 2926 1463 1.65 / 180.42 2 2
3 13 1643.64 21 14.75 2498 774 2.43 / 181.19 2 3
4 13 918.28 21 14.92 1568 491 2.92 / 181.68 2 2
5 13 369.80 21 15.08 859 272 3.19 / 181.96 2 2
6 13 108.28 21 15.17 477 152 3.34 / 182.11 2 3
7 8 0.08 165 15.17 312 781 4.12 / 182.89 3 8
Average= 3.98
(KJ/cycle)

Cycle 44 GMT 26/ 3/2019 3:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 15.14 451 184 0.18 / 174.99 3 3
2 7 2013.36 34 14.71 2943 1472 1.66 / 176.46 3 2
3 13 1377.72 21 14.82 2166 674 2.33 / 177.14 2 2
4 13 893.68 21 14.93 1535 481 2.81 / 177.62 2 2
5 13 242.04 21 15.13 689 219 3.03 / 177.84 2 2
6 13 85.36 21 15.18 443 141 3.17 / 177.98 2 3
7 8 0.00 165 15.18 314 786 3.96 / 178.76 3 5
Average= 3.97
(KJ/cycle)

Cycle 43 GMT 16/ 3/2019 5:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 27 15.15 453 185 0.19 / 170.88 3 3
2 7 2004.48 34 14.70 2954 1476 1.66 / 172.36 3 3
3 13 1494.20 21 14.80 2301 715 2.38 / 173.08 2 3
4 13 816.12 21 14.96 1437 451 2.83 / 173.53 2 3
5 13 293.60 21 15.11 773 245 3.07 / 173.77 2 2
6 13 96.12 21 15.18 461 147 3.22 / 173.92 2 3
7 13 20.28 21 15.20 340 109 3.33 / 174.03 2 3
8 8 0.00 165 15.17 311 778 4.11 / 174.81 2 3
Average= 3.97
(KJ/cycle)

Cycle 42 GMT 6/ 3/2019 7:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 27 15.15 463 189 0.19 / 166.84 3 3
2 7 2004.76 34 14.73 2912 1458 1.65 / 168.30 3 2
3 13 1508.04 21 14.79 2327 723 2.37 / 169.02 2 2
4 13 963.88 21 14.92 1623 509 2.88 / 169.53 2 2
5 13 261.76 21 15.12 729 231 3.11 / 169.76 2 2
6 13 102.20 21 15.18 478 152 3.26 / 169.92 2 3
7 8 0.00 165 15.18 313 784 4.05 / 170.70 3 5
Average= 3.97
(KJ/cycle)

Cycle 41 GMT 24/ 2/2019 9:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 27 15.15 452 185 0.18 / 162.83 3 3
2 7 2005.20 34 14.72 2961 1482 1.67 / 164.32 3 3
3 13 1500.52 21 14.80 2322 722 2.39 / 165.04 2 3
4 13 814.20 21 14.97 1429 449 2.84 / 165.49 2 3
5 13 285.40 21 15.12 750 238 3.08 / 165.73 2 3
6 13 83.64 21 15.19 441 141 3.22 / 165.87 2 3
7 8 0.12 165 15.18 314 786 4.00 / 166.65 3 4
Average= 3.97
(KJ/cycle)

Cycle 40 GMT 14/ 2/2019 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 27 15.16 452 185 0.19 / 158.71 3 3
2 7 2002.60 34 14.72 2939 1471 1.66 / 160.18 3 2
3 13 1501.24 21 14.80 2331 724 2.38 / 160.90 2 2
4 13 830.32 21 14.96 1461 459 2.84 / 161.36 2 3
5 13 303.92 21 15.11 783 248 3.09 / 161.61 2 2
6 13 80.72 21 15.19 443 141 3.23 / 161.75 2 3
7 13 16.40 21 15.21 346 111 3.34 / 161.86 2 3
8 8 0.12 165 15.17 315 788 4.13 / 162.65 3 7
Average= 3.97
(KJ/cycle)

Cycle 39 GMT 4/ 2/2019 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 27 15.16 462 189 0.19 / 154.66 3 3
2 7 2002.60 34 14.72 2930 1466 1.66 / 156.13 3 2
3 13 1525.28 21 14.80 2335 726 2.38 / 156.85 2 2
4 13 985.60 21 14.91 1656 519 2.90 / 157.37 2 2
5 13 260.20 21 15.13 720 229 3.13 / 157.60 2 3
6 13 83.44 21 15.20 439 140 3.27 / 157.74 2 3
7 8 0.04 165 15.19 311 779 4.05 / 158.52 3 4
Average= 3.96
(KJ/cycle)

Cycle 38 GMT 25/ 1/2019 15:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 27 15.17 445 182 0.18 / 150.63 3 3
2 7 2004.64 34 14.72 2934 1468 1.65 / 152.10 3 2
3 13 1492.52 21 14.81 2311 719 2.37 / 152.82 2 3
4 13 959.24 21 14.93 1621 508 2.88 / 153.33 2 2
5 13 268.16 21 15.14 725 231 3.11 / 153.56 2 3
6 13 90.08 21 15.20 444 142 3.25 / 153.70 2 3
7 8 0.08 165 15.19 308 772 4.02 / 154.47 3 5
Average= 3.96
(KJ/cycle)

Cycle 37 GMT 15/ 1/2019 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 27 15.17 454 186 0.19 / 146.62 3 3
2 7 2005.84 35 14.73 2920 1505 1.69 / 148.12 3 3
3 13 1484.60 21 14.82 2293 714 2.40 / 148.84 2 3
4 13 825.92 21 14.97 1451 456 2.86 / 149.29 2 2
5 13 295.96 21 15.13 761 242 3.10 / 149.53 2 2
6 13 87.20 21 15.20 445 142 3.24 / 149.68 2 3
7 8 0.20 165 15.20 309 775 4.02 / 150.45 3 4
Average= 3.96
(KJ/cycle)

Cycle 36 GMT 5/ 1/2019 19:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 15.17 440 180 0.18 / 142.55 3 3
2 7 2004.20 34 14.73 2925 1465 1.65 / 144.01 3 2
3 13 1661.48 21 14.77 2515 780 2.43 / 144.79 2 3
4 13 920.12 21 14.95 1569 493 2.92 / 145.29 2 2
5 13 241.00 21 15.15 693 220 3.14 / 145.51 2 3
6 13 79.96 21 15.21 438 140 3.28 / 145.65 2 3
7 8 0.08 165 15.20 313 785 4.06 / 146.43 3 7
Average= 3.96
(KJ/cycle)

Cycle 35 GMT 26/12/2018 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 27 15.16 456 187 0.19 / 138.48 3 3
2 7 2008.36 34 14.73 2951 1478 1.66 / 139.96 3 2
3 13 1699.48 21 14.77 2565 796 2.46 / 140.75 2 2
4 13 794.92 21 15.00 1404 442 2.90 / 141.19 2 2
5 13 291.16 21 15.13 763 242 3.14 / 141.44 2 2
6 13 95.00 21 15.21 464 148 3.29 / 141.59 2 3
7 8 0.08 165 15.20 312 782 4.08 / 142.37 3 4
Average= 3.95
(KJ/cycle)

Cycle 34 GMT 16/12/2018 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 27 15.18 445 182 0.18 / 134.46 3 3
2 7 2004.60 34 14.73 2930 1467 1.65 / 135.92 3 2
3 13 1514.40 21 14.81 2335 726 2.38 / 136.65 2 2
4 13 837.12 21 14.98 1443 454 2.83 / 137.10 2 2
5 13 317.64 21 15.12 803 255 3.08 / 137.36 2 2
6 13 84.88 21 15.20 451 144 3.23 / 137.50 2 3
7 8 0.12 165 15.20 315 790 4.02 / 138.29 2 6
Average= 3.95
(KJ/cycle)

Cycle 33 GMT 7/12/2018 1:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 27 15.17 455 186 0.19 / 130.49 3 3
2 7 2012.12 34 14.74 2943 1475 1.66 / 131.97 3 2
3 13 1497.48 21 14.82 2311 719 2.38 / 132.69 2 2
4 13 834.16 21 14.98 1468 462 2.84 / 133.15 2 2
5 13 206.32 21 15.17 647 206 3.05 / 133.36 2 2
6 13 65.24 21 15.22 420 134 3.18 / 133.49 2 3
7 8 -0.04 165 15.20 312 782 3.97 / 134.27 3 5
Average= 3.95
(KJ/cycle)

Cycle 32 GMT 27/11/2018 3:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 27 15.16 456 187 0.19 / 126.42 3 3
2 7 2005.88 34 14.74 2937 1472 1.66 / 127.89 3 2
3 13 1518.48 21 14.82 2309 719 2.38 / 128.61 2 3
4 13 983.56 21 14.94 1661 521 2.90 / 129.13 2 2
5 13 274.44 21 15.15 747 238 3.14 / 129.37 2 2
6 13 67.72 21 15.21 433 138 3.27 / 129.51 2 2
7 8 0.04 165 15.20 319 800 4.07 / 130.31 2 5
Average= 3.95
(KJ/cycle)

Cycle 31 GMT 17/11/2018 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 27 15.19 445 183 0.18 / 121.99 3 3
2 7 2007.12 34 14.74 2956 1481 1.66 / 123.47 3 2
3 13 1504.12 21 14.83 2323 723 2.39 / 124.19 2 2
4 13 961.92 21 14.94 1631 512 2.90 / 124.70 2 2
5 13 257.08 21 15.16 720 229 3.13 / 124.93 2 3
6 13 70.32 21 15.22 436 139 3.27 / 125.07 2 3
7 8 0.12 165 15.21 321 806 4.07 / 125.88 3 3
8 14 0.12 75 15.17 314 357 4.43 / 126.23 3 19
Average= 3.94
(KJ/cycle)

Cycle 30 GMT 7/11/2018 7:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 27 15.19 450 185 0.18 / 118.02 3 3
2 7 2004.48 34 14.75 2962 1485 1.67 / 119.50 2 2
3 13 1505.76 20 14.85 2309 686 2.36 / 120.19 2 2
4 13 840.00 20 15.00 1482 445 2.80 / 120.63 2 2
5 13 329.60 20 15.14 819 248 3.05 / 120.88 2 2
6 13 88.08 20 15.22 463 141 3.19 / 121.02 2 3
7 8 0.08 165 15.21 312 783 3.97 / 121.80 3 4
Average= 3.93
(KJ/cycle)

Cycle 29 GMT 28/10/2018 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 27 15.19 447 183 0.18 / 113.96 3 3
2 7 2002.00 34 14.75 2945 1477 1.66 / 115.44 3 3
3 13 1497.12 20 14.85 2334 693 2.35 / 116.13 2 2
4 13 832.16 20 15.00 1466 440 2.79 / 116.57 2 2
5 13 315.24 20 15.15 799 242 3.04 / 116.81 2 2
6 13 98.76 20 15.22 466 142 3.18 / 116.96 2 3
7 13 29.28 20 15.24 352 107 3.28 / 117.06 2 3
8 8 0.12 165 15.21 306 768 4.05 / 117.83 3 3
Average= 3.93
(KJ/cycle)

Cycle 28 GMT 18/10/2018 11:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 27 15.19 451 185 0.18 / 109.91 3 3
2 7 2003.12 34 14.75 2971 1490 1.67 / 111.40 2 3
3 13 1496.76 20 14.85 2310 686 2.36 / 112.09 2 2
4 13 824.72 20 15.00 1444 433 2.79 / 112.52 2 2
5 13 326.20 20 15.15 813 246 3.04 / 112.76 2 3
6 13 99.84 20 15.23 464 141 3.18 / 112.91 2 3
7 13 25.76 20 15.24 350 107 3.29 / 113.01 2 3
8 8 0.12 165 15.22 305 766 4.05 / 113.78 3 3
Average= 3.92
(KJ/cycle)

Cycle 27 GMT 8/10/2018 13:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 27 15.20 461 189 0.19 / 105.95 3 3
2 7 2009.68 34 14.75 2956 1482 1.67 / 107.43 3 2
3 13 1396.24 20 14.87 2191 652 2.32 / 108.08 2 2
4 13 892.04 20 14.98 1542 462 2.79 / 108.54 2 2
5 13 336.88 20 15.14 837 253 3.04 / 108.80 2 3
6 13 112.88 20 15.22 492 150 3.19 / 108.95 2 3
7 8 0.16 165 15.22 310 779 3.97 / 109.72 3 4
Average= 3.92
(KJ/cycle)

Cycle 26 GMT 28/ 9/2018 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 27 15.20 448 184 0.18 / 101.94 3 3
2 7 2004.44 34 14.75 2965 1487 1.67 / 103.43 3 2
3 13 1510.80 20 14.85 2331 692 2.36 / 104.12 2 2
4 13 840.24 20 15.01 1485 446 2.81 / 104.57 2 3
5 13 329.80 20 15.14 822 249 3.06 / 104.82 2 3
6 13 103.84 20 15.22 477 145 3.20 / 104.96 2 2
7 8 0.16 165 15.22 317 796 4.00 / 105.76 3 3
Average= 3.92
(KJ/cycle)

Cycle 25 GMT 18/ 9/2018 17:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 27 15.19 460 189 0.19 / 97.95 3 3
2 7 2002.08 34 14.77 2942 1477 1.67 / 99.43 3 2
3 13 1523.64 20 14.85 2362 702 2.37 / 100.13 2 2
4 13 846.08 20 15.00 1491 447 2.81 / 100.58 2 2
5 13 340.20 20 15.14 839 254 3.07 / 100.83 2 3
6 13 99.28 20 15.23 473 144 3.21 / 100.97 2 3
7 8 0.08 165 15.23 312 784 4.00 / 101.76 3 4
Average= 3.91
(KJ/cycle)

Cycle 24 GMT 8/ 9/2018 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 27 15.20 465 191 0.19 / 93.76 3 3
2 7 2009.88 34 14.76 2941 1476 1.67 / 95.24 3 2
3 13 1511.88 20 14.87 2291 681 2.35 / 95.92 2 2
4 13 981.40 20 14.96 1662 497 2.85 / 96.42 2 2
5 13 414.24 20 15.12 933 282 3.13 / 96.70 2 2
6 13 113.84 20 15.22 510 155 3.28 / 96.85 2 3
7 13 32.52 20 15.24 373 114 3.40 / 96.97 2 3
8 8 0.04 165 15.22 316 794 4.19 / 97.76 3 6
Average= 3.91
(KJ/cycle)

Cycle 23 GMT 29/ 8/2018 21: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 27 15.21 459 188 0.19 / 89.78 3 3
2 7 2009.44 34 14.76 2943 1477 1.67 / 91.25 3 2
3 13 1495.84 20 14.86 2317 689 2.35 / 91.94 2 2
4 13 842.88 20 15.01 1484 445 2.80 / 92.39 2 2
5 13 332.96 20 15.15 837 254 3.05 / 92.64 2 2
6 13 95.44 20 15.23 470 143 3.20 / 92.78 2 2
7 8 0.20 165 15.23 313 787 3.98 / 93.57 3 5
Average= 3.90
(KJ/cycle)

Cycle 22 GMT 19/ 8/2018 23:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 27 15.21 444 182 0.18 / 85.77 3 3
2 7 2005.04 34 14.77 2951 1482 1.66 / 87.25 3 2
3 13 1492.04 20 14.87 2309 687 2.35 / 87.94 2 2
4 13 972.72 20 14.98 1652 495 2.85 / 88.44 2 3
5 13 289.16 20 15.17 767 233 3.08 / 88.67 2 3
6 13 88.36 20 15.24 454 138 3.22 / 88.81 2 3
7 8 0.08 165 15.24 311 782 4.00 / 89.59 3 3
Average= 3.90
(KJ/cycle)

Cycle 21 GMT 10/ 8/2018 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 27 15.21 453 186 0.19 / 81.69 3 3
2 7 2007.56 34 14.78 2925 1470 1.66 / 83.16 3 2
3 13 1482.60 20 14.89 2281 679 2.34 / 83.84 2 2
4 13 966.00 20 14.98 1637 490 2.83 / 84.33 2 2
5 13 288.12 20 15.18 765 232 3.06 / 84.56 2 2
6 13 87.36 20 15.25 452 138 3.20 / 84.70 2 3
7 13 23.04 20 15.26 355 108 3.30 / 84.81 2 3
8 8 0.00 165 15.24 311 782 4.09 / 85.59 3 5
Average= 3.89
(KJ/cycle)

Cycle 20 GMT 31/ 7/2018 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 27 15.21 444 182 0.18 / 77.50 3 3
2 7 2008.44 34 14.78 2956 1485 1.67 / 78.99 3 2
3 13 1520.04 20 14.87 2359 702 2.37 / 79.69 2 2
4 13 1027.68 20 14.96 1723 516 2.88 / 80.21 2 2
5 13 343.20 20 15.16 843 256 3.14 / 80.46 2 2
6 13 103.00 20 15.24 480 146 3.29 / 80.61 2 3
7 13 22.48 20 15.26 353 108 3.39 / 80.72 2 3
8 8 0.04 165 15.23 313 787 4.18 / 81.50 3 7
Average= 3.88
(KJ/cycle)

Cycle 19 GMT 21/ 7/2018 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 27 15.22 464 191 0.19 / 73.32 3 3
2 7 2003.32 34 14.78 2952 1483 1.67 / 74.80 3 2
3 13 1653.16 20 14.85 2498 742 2.42 / 75.55 2 2
4 13 923.68 20 15.01 1568 471 2.89 / 76.02 2 2
5 13 371.08 20 15.15 886 268 3.16 / 76.29 2 2
6 13 106.84 20 15.24 488 149 3.30 / 76.43 2 3
7 13 23.36 20 15.27 356 109 3.41 / 76.54 2 3
8 8 -0.08 165 15.24 310 780 4.19 / 77.32 3 5
Average= 3.87
(KJ/cycle)

Cycle 18 GMT 11/ 7/2018 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 27 15.22 456 187 0.19 / 69.19 3 3
2 7 2005.76 34 14.78 2967 1491 1.68 / 70.68 3 2
3 13 1487.84 20 14.89 2313 689 2.37 / 71.37 2 2
4 13 970.56 20 14.99 1652 495 2.86 / 71.87 2 2
5 13 279.28 20 15.19 764 232 3.09 / 72.10 2 2
6 13 79.20 20 15.26 444 136 3.23 / 72.23 2 3
7 13 25.72 20 15.27 358 109 3.34 / 72.34 2 3
8 8 0.12 165 15.24 313 787 4.13 / 73.13 3 3
Average= 3.85
(KJ/cycle)

Cycle 17 GMT 1/ 7/2018 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 27 15.22 465 191 0.19 / 65.22 3 3
2 7 2006.12 34 14.80 2944 1481 1.67 / 66.70 3 2
3 13 1501.56 20 14.88 2323 691 2.36 / 67.39 2 2
4 13 825.44 20 15.03 1471 442 2.81 / 67.83 2 2
5 13 313.76 20 15.18 817 248 3.05 / 68.08 2 3
6 13 103.92 20 15.25 478 146 3.20 / 68.23 2 3
7 8 0.20 165 15.26 308 776 3.98 / 69.00 3 3
Average= 3.83
(KJ/cycle)

Cycle 16 GMT 21/ 6/2018 10:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 27 15.22 452 186 0.19 / 61.19 3 3
2 7 2012.28 34 14.79 2956 1486 1.67 / 62.67 3 2
3 13 1508.60 20 14.89 2305 686 2.36 / 63.36 2 2
4 13 972.32 20 15.00 1643 493 2.85 / 63.85 2 2
5 13 281.16 20 15.19 756 230 3.08 / 64.08 2 2
6 13 82.12 20 15.26 457 139 3.22 / 64.22 2 3
7 8 0.12 165 15.25 320 805 4.03 / 65.03 3 4
Average= 3.83
(KJ/cycle)

Cycle 15 GMT 11/ 6/2018 12:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 26 15.23 458 181 0.18 / 57.18 3 3
2 7 2007.16 34 14.80 2977 1498 1.68 / 58.67 2 3
3 13 1512.84 20 14.89 2344 698 2.38 / 59.37 2 2
4 13 835.20 20 15.04 1475 444 2.82 / 59.82 2 2
5 13 317.72 20 15.18 820 249 3.07 / 60.06 2 3
6 13 86.24 20 15.26 461 141 3.21 / 60.20 2 3
7 8 0.08 165 15.25 317 798 4.01 / 61.00 3 4
Average= 3.81
(KJ/cycle)

Cycle 14 GMT 1/ 6/2018 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 26 15.22 463 183 0.18 / 53.21 3 3
2 7 2004.08 34 14.81 2941 1481 1.66 / 54.69 3 3
3 13 1508.68 19 14.90 2304 652 2.32 / 55.34 2 2
4 13 988.88 19 15.00 1681 479 2.80 / 55.82 2 2
5 13 289.96 19 15.20 785 227 3.02 / 56.05 2 3
6 13 82.72 19 15.27 465 135 3.16 / 56.18 2 3
7 8 0.16 165 15.26 322 811 3.97 / 56.99 3 4
Average= 3.80
(KJ/cycle)

Cycle 13 GMT 22/ 5/2018 16:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 26 15.22 465 184 0.18 / 49.06 3 3
2 7 2008.52 34 14.81 2972 1497 1.68 / 50.56 3 2
3 13 1516.08 19 14.91 2318 657 2.34 / 51.21 2 2
4 13 982.36 19 15.01 1626 464 2.80 / 51.68 2 2
5 13 431.24 19 15.15 965 278 3.08 / 51.95 2 2
6 13 124.60 19 15.25 524 152 3.23 / 52.11 2 2
7 13 28.68 19 15.28 370 107 3.34 / 52.21 2 3
8 8 -0.08 165 15.25 323 813 4.15 / 53.03 3 4
Average= 3.79
(KJ/cycle)

Cycle 12 GMT 12/ 5/2018 18:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 26 15.23 455 180 0.18 / 45.12 3 3
2 7 2009.04 34 14.81 2961 1491 1.67 / 46.62 3 2
3 13 1386.20 19 14.94 2156 612 2.28 / 47.23 2 2
4 13 895.36 19 15.03 1559 445 2.73 / 47.67 2 2
5 13 359.80 19 15.17 872 251 2.98 / 47.92 2 2
6 13 99.00 19 15.26 485 141 3.12 / 48.06 2 2
7 8 0.16 165 15.26 322 811 3.93 / 48.88 3 4
Average= 3.76
(KJ/cycle)

Cycle 11 GMT 2/ 5/2018 20:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 26 15.23 464 184 0.18 / 41.04 3 3
2 7 2004.68 34 14.82 2963 1493 1.68 / 42.53 2 2
3 13 1495.60 19 14.91 2336 662 2.34 / 43.19 2 2
4 13 983.08 19 15.00 1669 476 2.81 / 43.67 2 2
5 13 291.40 19 15.20 782 226 3.04 / 43.89 2 2
6 13 104.12 19 15.26 491 142 3.18 / 44.03 2 3
7 13 25.64 19 15.29 360 105 3.29 / 44.14 2 3
8 8 0.08 165 15.26 320 806 4.09 / 44.94 3 4
Average= 3.75
(KJ/cycle)

Cycle 10 GMT 22/ 4/2018 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 26 15.22 477 189 0.19 / 37.00 3 3
2 7 2010.80 34 14.82 2953 1488 1.68 / 38.49 3 3
3 13 1499.36 19 14.92 2311 655 2.33 / 39.15 2 2
4 13 821.24 19 15.06 1461 418 2.75 / 39.57 2 2
5 13 318.24 19 15.19 821 237 2.99 / 39.80 2 3
6 13 99.04 19 15.27 480 139 3.13 / 39.94 2 2
7 13 26.32 19 15.29 366 106 3.23 / 40.05 2 3
8 8 0.04 165 15.26 319 803 4.04 / 40.85 3 3
Average= 3.71
(KJ/cycle)

Cycle 9 GMT 12/ 4/2018 23:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 26 15.23 467 185 0.18 / 32.89 3 3
2 7 2003.80 34 14.83 2960 1492 1.68 / 34.38 2 2
3 13 1496.36 19 14.91 2344 664 2.34 / 35.04 2 2
4 13 975.56 19 15.01 1669 476 2.82 / 35.52 2 2
5 13 276.76 19 15.21 767 222 3.04 / 35.74 2 2
6 13 86.48 19 15.27 475 138 3.18 / 35.88 2 3
7 13 25.00 19 15.28 374 109 3.29 / 35.99 2 3
8 8 0.24 165 15.26 329 828 4.11 / 36.82 2 3
Average= 3.68
(KJ/cycle)

Cycle 8 GMT 3/ 4/2018 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 26 15.23 459 182 0.18 / 28.82 3 3
2 7 2003.72 32 14.85 2955 1404 1.59 / 30.23 2 2
3 13 1511.92 19 14.91 2347 665 2.25 / 30.89 2 2
4 13 1003.92 19 15.01 1712 488 2.74 / 31.38 2 2
5 13 322.32 19 15.19 828 239 2.98 / 31.62 2 2
6 13 95.56 19 15.27 486 141 3.12 / 31.76 2 2
7 13 23.64 19 15.29 376 109 3.23 / 31.87 2 3
8 8 0.04 165 15.26 330 831 4.06 / 32.70 2 5
Average= 3.63
(KJ/cycle)

Cycle 7 GMT 24/ 3/2018 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 24 15.24 471 172 0.17 / 24.72 3 3
2 10 1020.88 2 15.17 1810 55 0.23 / 24.77 2 3
3 7 2005.64 32 14.84 2946 1399 1.63 / 26.17 3 2
4 13 1514.68 19 14.92 2356 668 2.29 / 26.84 2 2
5 13 998.76 19 15.01 1700 485 2.78 / 27.32 2 2
6 13 326.76 19 15.19 835 241 3.02 / 27.56 2 2
7 13 91.72 19 15.27 485 141 3.16 / 27.70 2 3
8 13 23.16 19 15.29 369 107 3.27 / 27.81 2 3
9 8 0.12 165 15.26 330 831 4.10 / 28.64 3 3
Average= 3.58
(KJ/cycle)

Cycle 6 GMT 14/ 3/2018 5: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 24 15.24 457 167 0.17 / 20.66 3 3
2 10 1052.24 2 15.18 1832 56 0.22 / 20.72 2 2
3 3 1034.48 1 15.25 1831 28 0.25 / 20.74 2 2
4 7 2001.60 37 14.84 2936 1612 1.86 / 22.36 2 2
5 13 1483.80 18 14.95 2275 612 2.47 / 22.97 2 2
6 13 937.68 18 15.04 1624 440 2.91 / 23.41 2 2
7 13 251.44 18 15.23 731 200 3.12 / 23.61 2 2
8 13 80.76 18 15.28 460 127 3.24 / 23.74 2 3
9 8 0.24 165 15.27 321 809 4.05 / 24.54 2 7
Average= 3.51
(KJ/cycle)

Cycle 5 GMT 4/ 3/2018 7: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 23 15.24 457 160 0.16 / 16.72 3 3
2 10 1009.32 2 15.18 1780 54 0.21 / 16.78 2 2
3 7 2003.00 36 14.83 2938 1569 1.78 / 18.35 2 2
4 13 1314.40 18 14.97 2105 567 2.35 / 18.91 2 2
5 13 833.60 18 15.07 1482 402 2.75 / 19.32 2 2
6 13 322.68 18 15.20 831 227 2.98 / 19.54 2 2
7 13 99.28 18 15.27 490 135 3.11 / 19.68 2 3
8 8 0.08 165 15.27 324 816 3.93 / 20.49 2 4
Average= 3.42
(KJ/cycle)

Cycle 4 GMT 22/ 2/2018 8:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 24 15.23 451 165 0.16 / 13.37 3 3
2 7 1508.88 36 14.99 2324 1254 1.42 / 14.62 2 3
3 13 1206.04 18 15.03 1960 530 1.95 / 15.15 2 2
4 13 564.24 18 15.16 1140 311 2.26 / 15.46 2 2
5 13 148.00 18 15.27 577 159 2.42 / 15.62 2 3
6 13 84.44 18 15.29 462 127 2.55 / 15.75 2 3
7 8 0.16 165 15.28 324 817 3.36 / 16.56 3 4
Average= 3.31
(KJ/cycle)

Cycle 3 GMT 21/ 2/2018 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 24 15.22 446 163 0.16 / 9.14 3 3
2 7 1517.36 74 14.89 2328 2565 2.73 / 11.70 3 3
3 13 150.88 22 15.26 579 194 2.92 / 11.90 2 2
4 13 47.48 22 15.30 395 133 3.06 / 12.03 2 2
5 8 0.12 240 15.26 320 1172 4.23 / 13.20 3 22
Average= 3.30
(KJ/cycle)

Cycle 2 GMT 20/ 2/2018 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 24 15.26 476 174 0.17 / 4.92 3 3
2 7 1523.28 74 14.90 2318 2556 2.73 / 7.48 3 3
3 13 143.44 22 15.27 562 189 2.92 / 7.67 2 2
4 13 43.08 22 15.30 391 132 3.05 / 7.80 2 3
5 8 0.08 240 15.26 321 1176 4.23 / 8.97 2 20
Average= 2.99
(KJ/cycle)

Cycle 1 GMT 19/ 2/2018 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 23 15.49 397 141 0.14 / 1.63 3 3
2 3 1033.80 1 15.28 1812 28 0.17 / 1.66 2 2
3 7 1013.04 74 15.06 1680 1872 2.04 / 3.53 2 2
4 8 0.16 240 15.31 330 1213 3.25 / 4.75 2 8
Average= 2.37
(KJ/cycle)

Cycle 0 GMT 19/ 2/2018 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 22 15.64 391 135 0.13 / 0.13 3 3
2 7 117.20 74 15.60 407 470 0.60 / 0.60 3 3
3 8 0.24 240 15.56 238 889 1.49 / 1.49 3 20
Average= 1.49
(KJ/cycle)