SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 29 | 14.81 | 510 | 219 | 0.22 / 1347.20 | 2 | 3 |
2 | 7 | 2003.20 | 43 | 14.27 | 3144 | 1929 | 2.15 / 1349.13 | 2 | 3 |
3 | 13 | 1735.24 | 19 | 14.28 | 2781 | 755 | 2.90 / 1349.89 | 2 | 4 |
4 | 13 | 997.28 | 19 | 14.51 | 1776 | 490 | 3.39 / 1350.38 | 2 | 5 |
5 | 13 | 426.72 | 19 | 14.74 | 969 | 271 | 3.66 / 1350.65 | 2 | 5 |
6 | 8 | 0.00 | 170 | 14.87 | 359 | 908 | 4.57 / 1351.55 | 2 | 11 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 29 | 15.00 | 512 | 223 | 0.22 / 1342.51 | 2 | 3 |
2 | 7 | 2005.20 | 44 | 14.26 | 3138 | 1969 | 2.19 / 1344.48 | 3 | 4 |
3 | 13 | 1593.52 | 19 | 14.31 | 2589 | 704 | 2.90 / 1345.19 | 2 | 3 |
4 | 13 | 1013.28 | 19 | 14.50 | 1795 | 495 | 3.39 / 1345.68 | 2 | 4 |
5 | 13 | 439.52 | 19 | 14.74 | 981 | 275 | 3.66 / 1345.95 | 2 | 4 |
6 | 13 | 13.04 | 19 | 14.92 | 396 | 112 | 3.78 / 1346.07 | 2 | 4 |
7 | 8 | 0.56 | 170 | 14.85 | 363 | 916 | 4.69 / 1346.98 | 2 | 12 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 29 | 14.82 | 523 | 225 | 0.22 / 1337.86 | 2 | 3 |
2 | 7 | 2007.52 | 43 | 14.27 | 3149 | 1932 | 2.16 / 1339.80 | 2 | 2 |
3 | 13 | 1739.92 | 19 | 14.29 | 2789 | 757 | 2.91 / 1340.55 | 2 | 6 |
4 | 13 | 1151.44 | 19 | 14.45 | 1995 | 548 | 3.46 / 1341.10 | 2 | 7 |
5 | 13 | 430.96 | 19 | 14.75 | 973 | 273 | 3.73 / 1341.37 | 2 | 4 |
6 | 8 | -0.32 | 170 | 14.87 | 362 | 915 | 4.65 / 1342.29 | 2 | 16 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 29 | 14.98 | 526 | 229 | 0.23 / 1333.30 | 2 | 2 |
2 | 7 | 2002.64 | 43 | 14.27 | 3138 | 1926 | 2.15 / 1335.23 | 2 | 2 |
3 | 13 | 1597.28 | 19 | 14.32 | 2610 | 710 | 2.86 / 1335.94 | 2 | 5 |
4 | 13 | 1015.68 | 19 | 14.51 | 1810 | 499 | 3.36 / 1336.44 | 2 | 6 |
5 | 13 | 437.92 | 19 | 14.74 | 982 | 275 | 3.64 / 1336.71 | 2 | 4 |
6 | 8 | -0.08 | 170 | 14.86 | 368 | 930 | 4.57 / 1337.64 | 2 | 16 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 29 | 15.00 | 513 | 223 | 0.22 / 1328.62 | 2 | 3 |
2 | 7 | 2003.92 | 43 | 14.27 | 3143 | 1929 | 2.15 / 1330.55 | 2 | 3 |
3 | 13 | 1599.24 | 19 | 14.31 | 2612 | 710 | 2.86 / 1331.26 | 2 | 7 |
4 | 13 | 1031.56 | 19 | 14.50 | 1823 | 502 | 3.36 / 1331.76 | 2 | 4 |
5 | 13 | 444.88 | 19 | 14.74 | 992 | 278 | 3.64 / 1332.04 | 2 | 5 |
6 | 13 | 15.80 | 19 | 14.91 | 401 | 114 | 3.76 / 1332.15 | 2 | 5 |
7 | 8 | -0.28 | 170 | 14.85 | 364 | 919 | 4.67 / 1333.07 | 2 | 8 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 29 | 14.82 | 517 | 222 | 0.22 / 1324.09 | 2 | 3 |
2 | 7 | 2002.80 | 43 | 14.28 | 3136 | 1926 | 2.15 / 1326.01 | 3 | 3 |
3 | 13 | 1584.92 | 19 | 14.32 | 2582 | 703 | 2.85 / 1326.71 | 2 | 3 |
4 | 13 | 1019.96 | 19 | 14.50 | 1806 | 498 | 3.35 / 1327.21 | 2 | 5 |
5 | 13 | 451.36 | 19 | 14.74 | 992 | 278 | 3.63 / 1327.49 | 2 | 5 |
6 | 8 | 1.52 | 170 | 14.87 | 359 | 908 | 4.53 / 1328.40 | 2 | 11 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 29 | 14.81 | 518 | 222 | 0.22 / 1319.38 | 2 | 3 |
2 | 7 | 2001.72 | 43 | 14.28 | 3143 | 1930 | 2.15 / 1321.31 | 3 | 2 |
3 | 13 | 1717.12 | 19 | 14.29 | 2764 | 750 | 2.90 / 1322.06 | 2 | 4 |
4 | 13 | 994.48 | 19 | 14.52 | 1772 | 489 | 3.39 / 1322.55 | 2 | 8 |
5 | 13 | 422.56 | 19 | 14.75 | 960 | 269 | 3.66 / 1322.82 | 2 | 5 |
6 | 13 | 60.08 | 19 | 14.90 | 457 | 129 | 3.79 / 1322.95 | 2 | 6 |
7 | 8 | -0.12 | 170 | 14.86 | 362 | 914 | 4.70 / 1323.86 | 2 | 10 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 29 | 14.82 | 508 | 218 | 0.22 / 1314.80 | 2 | 3 |
2 | 7 | 2003.16 | 43 | 14.28 | 3142 | 1929 | 2.15 / 1316.73 | 3 | 2 |
3 | 13 | 1592.32 | 19 | 14.32 | 2600 | 707 | 2.86 / 1317.44 | 2 | 5 |
4 | 13 | 1024.44 | 19 | 14.51 | 1813 | 500 | 3.35 / 1317.94 | 2 | 5 |
5 | 13 | 447.28 | 19 | 14.74 | 1001 | 280 | 3.64 / 1318.22 | 2 | 5 |
6 | 8 | 0.00 | 170 | 14.86 | 373 | 942 | 4.58 / 1319.16 | 2 | 12 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 29 | 14.80 | 529 | 227 | 0.23 / 1310.33 | 2 | 4 |
2 | 7 | 2003.80 | 43 | 14.28 | 3134 | 1924 | 2.15 / 1312.25 | 2 | 4 |
3 | 13 | 1597.80 | 19 | 14.31 | 2608 | 709 | 2.86 / 1312.96 | 2 | 5 |
4 | 13 | 897.64 | 19 | 14.56 | 1636 | 453 | 3.31 / 1313.41 | 2 | 8 |
5 | 13 | 346.16 | 19 | 14.78 | 858 | 241 | 3.55 / 1313.65 | 2 | 5 |
6 | 8 | 0.20 | 170 | 14.87 | 368 | 930 | 4.48 / 1314.58 | 2 | 10 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 29 | 14.98 | 521 | 226 | 0.23 / 1305.73 | 2 | 3 |
2 | 7 | 2008.56 | 43 | 14.27 | 3142 | 1928 | 2.15 / 1307.65 | 2 | 2 |
3 | 13 | 1591.08 | 19 | 14.32 | 2600 | 707 | 2.86 / 1308.36 | 2 | 4 |
4 | 13 | 1041.00 | 19 | 14.50 | 1835 | 506 | 3.37 / 1308.87 | 2 | 8 |
5 | 13 | 449.72 | 19 | 14.74 | 1001 | 280 | 3.65 / 1309.15 | 2 | 5 |
6 | 8 | 0.12 | 170 | 14.86 | 376 | 950 | 4.60 / 1310.10 | 2 | 12 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 29 | 14.80 | 529 | 227 | 0.23 / 1300.98 | 2 | 5 |
2 | 7 | 2005.00 | 44 | 14.28 | 3132 | 1968 | 2.19 / 1302.95 | 5 | 3 |
3 | 13 | 1587.44 | 19 | 14.31 | 2599 | 707 | 2.90 / 1303.66 | 2 | 5 |
4 | 13 | 1151.64 | 19 | 14.44 | 1997 | 548 | 3.45 / 1304.21 | 2 | 6 |
5 | 13 | 408.28 | 19 | 14.76 | 940 | 264 | 3.71 / 1304.47 | 2 | 6 |
6 | 13 | 28.12 | 19 | 14.91 | 424 | 120 | 3.83 / 1304.59 | 2 | 4 |
7 | 8 | 0.00 | 170 | 14.85 | 361 | 911 | 4.74 / 1305.50 | 2 | 16 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 29 | 14.81 | 518 | 222 | 0.22 / 1296.27 | 2 | 4 |
2 | 7 | 2008.56 | 43 | 14.28 | 3135 | 1925 | 2.15 / 1298.20 | 2 | 3 |
3 | 13 | 1601.52 | 19 | 14.31 | 2628 | 715 | 2.86 / 1298.91 | 2 | 6 |
4 | 13 | 1030.00 | 19 | 14.50 | 1833 | 505 | 3.37 / 1299.42 | 2 | 6 |
5 | 13 | 467.16 | 19 | 14.73 | 1023 | 286 | 3.65 / 1299.71 | 2 | 4 |
6 | 13 | 17.12 | 19 | 14.91 | 411 | 116 | 3.77 / 1299.82 | 2 | 4 |
7 | 8 | 0.56 | 170 | 14.85 | 370 | 934 | 4.70 / 1300.76 | 2 | 11 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 29 | 14.80 | 528 | 227 | 0.23 / 1291.73 | 2 | 4 |
2 | 7 | 2006.96 | 43 | 14.28 | 3130 | 1922 | 2.15 / 1293.65 | 4 | 2 |
3 | 13 | 1594.52 | 19 | 14.31 | 2602 | 707 | 2.86 / 1294.36 | 2 | 4 |
4 | 13 | 913.12 | 19 | 14.56 | 1665 | 461 | 3.32 / 1294.82 | 2 | 4 |
5 | 13 | 485.96 | 19 | 14.72 | 1052 | 294 | 3.61 / 1295.11 | 2 | 5 |
6 | 8 | -0.04 | 170 | 14.86 | 373 | 942 | 4.55 / 1296.05 | 2 | 11 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 29 | 14.98 | 522 | 227 | 0.23 / 1286.99 | 2 | 4 |
2 | 7 | 2004.88 | 44 | 14.27 | 3123 | 1961 | 2.19 / 1288.95 | 2 | 4 |
3 | 13 | 1597.28 | 19 | 14.31 | 2616 | 711 | 2.90 / 1289.66 | 2 | 6 |
4 | 13 | 1021.40 | 19 | 14.51 | 1822 | 502 | 3.40 / 1290.16 | 2 | 5 |
5 | 13 | 428.72 | 19 | 14.75 | 970 | 272 | 3.67 / 1290.43 | 2 | 5 |
6 | 13 | 27.60 | 19 | 14.90 | 427 | 121 | 3.79 / 1290.56 | 2 | 4 |
7 | 8 | 0.16 | 170 | 14.84 | 374 | 944 | 4.74 / 1291.50 | 2 | 14 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 29 | 14.97 | 532 | 231 | 0.23 / 1282.47 | 2 | 3 |
2 | 7 | 2009.00 | 43 | 14.28 | 3135 | 1925 | 2.16 / 1284.39 | 2 | 2 |
3 | 13 | 1482.96 | 19 | 14.35 | 2469 | 673 | 2.83 / 1285.07 | 2 | 5 |
4 | 13 | 1064.96 | 19 | 14.49 | 1876 | 516 | 3.35 / 1285.58 | 2 | 7 |
5 | 13 | 344.16 | 19 | 14.78 | 855 | 240 | 3.59 / 1285.82 | 2 | 4 |
6 | 8 | 0.20 | 170 | 14.86 | 371 | 937 | 4.52 / 1286.76 | 2 | 12 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 29 | 14.81 | 523 | 225 | 0.22 / 1277.69 | 2 | 4 |
2 | 7 | 2009.12 | 44 | 14.27 | 3123 | 1961 | 2.19 / 1279.65 | 2 | 3 |
3 | 13 | 1610.16 | 19 | 14.30 | 2638 | 717 | 2.90 / 1280.37 | 2 | 6 |
4 | 13 | 1046.80 | 19 | 14.50 | 1839 | 507 | 3.41 / 1280.87 | 2 | 7 |
5 | 13 | 322.68 | 19 | 14.80 | 819 | 230 | 3.64 / 1281.10 | 2 | 4 |
6 | 13 | 18.04 | 19 | 14.92 | 401 | 114 | 3.75 / 1281.22 | 2 | 4 |
7 | 8 | 0.00 | 170 | 14.85 | 362 | 914 | 4.67 / 1282.13 | 2 | 12 |
8 | 14 | 0.00 | 20 | 14.83 | 367 | 109 | 4.78 / 1282.24 | 2 | 14 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 29 | 14.81 | 522 | 224 | 0.22 / 1273.12 | 2 | 4 |
2 | 7 | 2007.32 | 44 | 14.27 | 3153 | 1980 | 2.20 / 1275.10 | 2 | 3 |
3 | 13 | 1590.72 | 19 | 14.31 | 2605 | 708 | 2.91 / 1275.81 | 2 | 4 |
4 | 13 | 1016.44 | 19 | 14.51 | 1802 | 497 | 3.41 / 1276.30 | 2 | 6 |
5 | 13 | 315.04 | 19 | 14.81 | 810 | 228 | 3.64 / 1276.53 | 2 | 5 |
6 | 8 | 0.04 | 170 | 14.86 | 369 | 932 | 4.57 / 1277.46 | 2 | 12 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 29 | 14.98 | 534 | 232 | 0.23 / 1268.43 | 2 | 3 |
2 | 7 | 2002.60 | 43 | 14.27 | 3151 | 1933 | 2.17 / 1270.36 | 2 | 3 |
3 | 13 | 1597.04 | 19 | 14.32 | 2609 | 710 | 2.88 / 1271.07 | 2 | 6 |
4 | 13 | 1013.80 | 19 | 14.51 | 1812 | 500 | 3.37 / 1271.57 | 2 | 4 |
5 | 13 | 435.92 | 19 | 14.75 | 982 | 275 | 3.65 / 1271.84 | 2 | 4 |
6 | 13 | 29.00 | 19 | 14.91 | 428 | 121 | 3.77 / 1271.97 | 2 | 4 |
7 | 8 | 0.20 | 170 | 14.85 | 368 | 929 | 4.70 / 1272.89 | 2 | 12 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 29 | 15.00 | 521 | 227 | 0.23 / 1263.85 | 2 | 3 |
2 | 7 | 2001.64 | 43 | 14.28 | 3132 | 1923 | 2.15 / 1265.77 | 2 | 3 |
3 | 13 | 1584.12 | 19 | 14.33 | 2595 | 707 | 2.86 / 1266.48 | 2 | 6 |
4 | 13 | 1003.64 | 19 | 14.52 | 1781 | 491 | 3.35 / 1266.97 | 2 | 8 |
5 | 13 | 436.52 | 19 | 14.75 | 990 | 277 | 3.63 / 1267.25 | 2 | 5 |
6 | 8 | 0.28 | 170 | 14.86 | 375 | 947 | 4.57 / 1268.19 | 2 | 19 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 29 | 14.98 | 529 | 230 | 0.23 / 1259.27 | 2 | 3 |
2 | 7 | 2005.48 | 43 | 14.28 | 3117 | 1914 | 2.14 / 1261.18 | 2 | 4 |
3 | 13 | 1729.64 | 19 | 14.29 | 2775 | 753 | 2.90 / 1261.94 | 2 | 5 |
4 | 13 | 999.20 | 19 | 14.53 | 1772 | 489 | 3.39 / 1262.43 | 2 | 7 |
5 | 13 | 434.88 | 19 | 14.75 | 979 | 274 | 3.66 / 1262.70 | 2 | 4 |
6 | 8 | 0.00 | 170 | 14.87 | 364 | 920 | 4.58 / 1263.62 | 2 | 13 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 29 | 14.82 | 515 | 221 | 0.22 / 1254.45 | 2 | 3 |
2 | 7 | 2006.56 | 44 | 14.27 | 3142 | 1973 | 2.19 / 1256.42 | 2 | 4 |
3 | 13 | 1590.72 | 19 | 14.32 | 2595 | 706 | 2.90 / 1257.13 | 2 | 3 |
4 | 13 | 999.08 | 19 | 14.52 | 1771 | 489 | 3.39 / 1257.61 | 2 | 6 |
5 | 13 | 413.24 | 19 | 14.76 | 946 | 265 | 3.65 / 1257.88 | 2 | 5 |
6 | 13 | 78.40 | 19 | 14.90 | 485 | 137 | 3.79 / 1258.02 | 2 | 6 |
7 | 13 | 42.76 | 19 | 14.90 | 434 | 123 | 3.91 / 1258.14 | 2 | 5 |
8 | 8 | -0.08 | 170 | 14.85 | 357 | 901 | 4.82 / 1259.04 | 2 | 22 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 29 | 14.81 | 528 | 227 | 0.23 / 1249.97 | 2 | 3 |
2 | 7 | 2004.04 | 43 | 14.28 | 3144 | 1931 | 2.16 / 1251.90 | 2 | 4 |
3 | 13 | 1599.72 | 19 | 14.32 | 2611 | 710 | 2.87 / 1252.61 | 2 | 4 |
4 | 13 | 892.28 | 19 | 14.57 | 1628 | 451 | 3.32 / 1253.06 | 2 | 5 |
5 | 13 | 335.16 | 19 | 14.79 | 850 | 239 | 3.56 / 1253.30 | 2 | 6 |
6 | 8 | 0.28 | 170 | 14.87 | 367 | 928 | 4.48 / 1254.22 | 2 | 11 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 29 | 14.82 | 519 | 223 | 0.22 / 1245.25 | 2 | 3 |
2 | 7 | 2003.12 | 43 | 14.28 | 3156 | 1938 | 2.16 / 1247.18 | 2 | 4 |
3 | 13 | 1588.92 | 19 | 14.32 | 2600 | 707 | 2.87 / 1247.89 | 2 | 5 |
4 | 13 | 1019.48 | 19 | 14.51 | 1818 | 501 | 3.37 / 1248.39 | 2 | 5 |
5 | 13 | 439.08 | 19 | 14.75 | 998 | 280 | 3.65 / 1248.67 | 2 | 5 |
6 | 13 | 13.96 | 19 | 14.92 | 409 | 116 | 3.77 / 1248.79 | 2 | 5 |
7 | 8 | 0.04 | 170 | 14.85 | 377 | 952 | 4.72 / 1249.74 | 2 | 10 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 29 | 14.82 | 529 | 227 | 0.23 / 1240.77 | 2 | 3 |
2 | 7 | 2003.52 | 44 | 14.28 | 3151 | 1980 | 2.21 / 1242.75 | 2 | 3 |
3 | 13 | 1457.84 | 19 | 14.36 | 2432 | 664 | 2.87 / 1243.41 | 2 | 4 |
4 | 13 | 891.92 | 19 | 14.56 | 1628 | 450 | 3.32 / 1243.86 | 2 | 4 |
5 | 13 | 326.76 | 19 | 14.80 | 835 | 235 | 3.56 / 1244.10 | 2 | 6 |
6 | 8 | 0.44 | 170 | 14.87 | 366 | 925 | 4.48 / 1245.02 | 2 | 16 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 29 | 14.83 | 515 | 221 | 0.22 / 1236.15 | 2 | 3 |
2 | 7 | 2002.48 | 43 | 14.29 | 3128 | 1922 | 2.14 / 1238.07 | 3 | 4 |
3 | 13 | 1597.40 | 19 | 14.33 | 2615 | 712 | 2.86 / 1238.78 | 2 | 4 |
4 | 13 | 1040.72 | 19 | 14.51 | 1827 | 504 | 3.36 / 1239.29 | 2 | 4 |
5 | 13 | 332.92 | 19 | 14.80 | 830 | 233 | 3.59 / 1239.52 | 2 | 5 |
6 | 13 | 18.76 | 19 | 14.93 | 399 | 113 | 3.71 / 1239.63 | 2 | 4 |
7 | 8 | 0.12 | 170 | 14.87 | 360 | 910 | 4.62 / 1240.54 | 2 | 8 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 29 | 14.82 | 505 | 217 | 0.22 / 1231.59 | 2 | 3 |
2 | 7 | 2007.04 | 43 | 14.29 | 3150 | 1936 | 2.15 / 1233.52 | 2 | 2 |
3 | 13 | 1601.12 | 19 | 14.33 | 2615 | 712 | 2.86 / 1234.23 | 2 | 4 |
4 | 13 | 1030.36 | 19 | 14.51 | 1828 | 504 | 3.37 / 1234.74 | 2 | 5 |
5 | 13 | 444.00 | 19 | 14.75 | 990 | 277 | 3.65 / 1235.02 | 2 | 4 |
6 | 8 | -0.12 | 170 | 14.88 | 360 | 911 | 4.56 / 1235.93 | 2 | 11 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 28 | 14.84 | 517 | 215 | 0.21 / 1226.89 | 2 | 2 |
2 | 7 | 2004.00 | 43 | 14.29 | 3135 | 1926 | 2.14 / 1228.81 | 2 | 4 |
3 | 13 | 1592.64 | 19 | 14.34 | 2610 | 711 | 2.85 / 1229.53 | 2 | 5 |
4 | 13 | 1043.32 | 19 | 14.50 | 1852 | 510 | 3.36 / 1230.04 | 2 | 4 |
5 | 13 | 458.52 | 19 | 14.74 | 1024 | 287 | 3.65 / 1230.32 | 2 | 5 |
6 | 13 | 15.32 | 19 | 14.93 | 404 | 115 | 3.76 / 1230.44 | 2 | 5 |
7 | 8 | 0.08 | 170 | 14.86 | 369 | 932 | 4.70 / 1231.37 | 2 | 12 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 28 | 14.97 | 501 | 210 | 0.21 / 1222.34 | 2 | 2 |
2 | 7 | 2008.76 | 43 | 14.29 | 3140 | 1929 | 2.14 / 1224.27 | 2 | 2 |
3 | 13 | 1600.48 | 19 | 14.33 | 2601 | 708 | 2.85 / 1224.98 | 2 | 5 |
4 | 13 | 1034.68 | 19 | 14.51 | 1824 | 503 | 3.35 / 1225.48 | 2 | 5 |
5 | 13 | 459.48 | 19 | 14.74 | 1013 | 284 | 3.63 / 1225.76 | 2 | 4 |
6 | 8 | 0.32 | 170 | 14.88 | 360 | 911 | 4.54 / 1226.67 | 2 | 16 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 28 | 15.02 | 502 | 211 | 0.21 / 1217.83 | 2 | 2 |
2 | 7 | 2004.52 | 43 | 14.29 | 3133 | 1925 | 2.14 / 1219.75 | 2 | 3 |
3 | 13 | 1466.44 | 19 | 14.37 | 2420 | 661 | 2.80 / 1220.41 | 2 | 5 |
4 | 13 | 922.92 | 19 | 14.55 | 1667 | 461 | 3.26 / 1220.87 | 2 | 4 |
5 | 13 | 355.00 | 19 | 14.78 | 867 | 243 | 3.50 / 1221.12 | 2 | 4 |
6 | 13 | 22.28 | 19 | 14.93 | 401 | 114 | 3.62 / 1221.23 | 2 | 4 |
7 | 8 | -0.32 | 170 | 14.87 | 355 | 897 | 4.51 / 1222.13 | 2 | 18 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 29 | 15.03 | 513 | 224 | 0.22 / 1213.38 | 2 | 2 |
2 | 7 | 2006.56 | 43 | 14.29 | 3137 | 1928 | 2.15 / 1215.31 | 2 | 4 |
3 | 13 | 1457.00 | 19 | 14.37 | 2412 | 659 | 2.81 / 1215.97 | 2 | 4 |
4 | 13 | 1043.32 | 19 | 14.50 | 1840 | 507 | 3.32 / 1216.47 | 2 | 5 |
5 | 13 | 327.04 | 19 | 14.80 | 826 | 232 | 3.55 / 1216.71 | 2 | 4 |
6 | 8 | 0.80 | 170 | 14.87 | 360 | 910 | 4.46 / 1217.62 | 2 | 9 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 29 | 14.83 | 508 | 218 | 0.22 / 1208.76 | 2 | 3 |
2 | 7 | 2004.12 | 43 | 14.30 | 3143 | 1933 | 2.15 / 1210.69 | 3 | 3 |
3 | 13 | 1595.16 | 19 | 14.33 | 2600 | 708 | 2.86 / 1211.40 | 2 | 4 |
4 | 13 | 913.40 | 19 | 14.56 | 1655 | 458 | 3.32 / 1211.86 | 2 | 7 |
5 | 13 | 488.64 | 19 | 14.73 | 1048 | 293 | 3.61 / 1212.15 | 2 | 5 |
6 | 13 | 20.48 | 19 | 14.93 | 401 | 114 | 3.72 / 1212.26 | 2 | 5 |
7 | 8 | 0.08 | 170 | 14.87 | 353 | 892 | 4.62 / 1213.16 | 2 | 18 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 28 | 14.82 | 506 | 210 | 0.21 / 1204.32 | 2 | 2 |
2 | 7 | 2004.48 | 43 | 14.30 | 3137 | 1929 | 2.14 / 1206.25 | 2 | 3 |
3 | 13 | 1467.76 | 19 | 14.37 | 2430 | 663 | 2.80 / 1206.91 | 2 | 4 |
4 | 13 | 1037.60 | 19 | 14.50 | 1829 | 504 | 3.31 / 1207.42 | 2 | 4 |
5 | 13 | 329.72 | 19 | 14.80 | 835 | 235 | 3.54 / 1207.65 | 2 | 4 |
6 | 8 | 0.64 | 170 | 14.88 | 351 | 888 | 4.43 / 1208.54 | 2 | 9 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 29 | 15.01 | 513 | 223 | 0.22 / 1199.68 | 2 | 2 |
2 | 7 | 2008.52 | 44 | 14.28 | 3148 | 1978 | 2.20 / 1201.66 | 2 | 3 |
3 | 13 | 1592.60 | 19 | 14.33 | 2588 | 705 | 2.91 / 1202.36 | 2 | 6 |
4 | 13 | 1014.52 | 19 | 14.52 | 1802 | 497 | 3.40 / 1202.86 | 2 | 8 |
5 | 13 | 299.32 | 19 | 14.82 | 790 | 222 | 3.63 / 1203.08 | 2 | 4 |
6 | 13 | 75.52 | 19 | 14.90 | 478 | 135 | 3.76 / 1203.22 | 2 | 4 |
7 | 8 | 0.12 | 170 | 14.87 | 354 | 895 | 4.66 / 1204.11 | 2 | 17 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 29 | 14.83 | 516 | 222 | 0.22 / 1195.13 | 2 | 3 |
2 | 7 | 2004.84 | 43 | 14.30 | 3123 | 1920 | 2.14 / 1197.05 | 3 | 2 |
3 | 13 | 1592.60 | 19 | 14.33 | 2601 | 708 | 2.85 / 1197.76 | 2 | 7 |
4 | 13 | 898.88 | 19 | 14.57 | 1632 | 452 | 3.30 / 1198.21 | 2 | 5 |
5 | 13 | 340.76 | 19 | 14.80 | 842 | 237 | 3.54 / 1198.45 | 2 | 4 |
6 | 13 | 20.48 | 19 | 14.93 | 399 | 113 | 3.65 / 1198.56 | 2 | 5 |
7 | 8 | -0.40 | 170 | 14.87 | 354 | 895 | 4.55 / 1199.46 | 2 | 12 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 29 | 14.83 | 511 | 220 | 0.22 / 1190.54 | 2 | 3 |
2 | 7 | 2002.80 | 43 | 14.30 | 3134 | 1927 | 2.15 / 1192.46 | 2 | 3 |
3 | 13 | 1732.20 | 19 | 14.30 | 2799 | 760 | 2.91 / 1193.23 | 2 | 4 |
4 | 13 | 995.72 | 19 | 14.53 | 1772 | 489 | 3.40 / 1193.71 | 2 | 5 |
5 | 13 | 429.36 | 19 | 14.76 | 970 | 272 | 3.67 / 1193.99 | 2 | 5 |
6 | 8 | 0.48 | 170 | 14.87 | 365 | 923 | 4.59 / 1194.91 | 2 | 11 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 29 | 14.84 | 511 | 220 | 0.22 / 1185.90 | 2 | 2 |
2 | 7 | 2006.28 | 43 | 14.30 | 3127 | 1923 | 2.14 / 1187.82 | 2 | 2 |
3 | 13 | 1742.40 | 19 | 14.29 | 2798 | 760 | 2.90 / 1188.58 | 2 | 3 |
4 | 13 | 1150.68 | 19 | 14.46 | 1996 | 548 | 3.45 / 1189.13 | 2 | 6 |
5 | 13 | 404.04 | 19 | 14.77 | 942 | 264 | 3.72 / 1189.40 | 2 | 5 |
6 | 8 | -0.28 | 170 | 14.87 | 365 | 923 | 4.64 / 1190.32 | 2 | 10 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 29 | 15.03 | 510 | 222 | 0.22 / 1181.36 | 2 | 2 |
2 | 7 | 2002.32 | 43 | 14.29 | 3138 | 1928 | 2.15 / 1183.29 | 2 | 3 |
3 | 13 | 1592.64 | 19 | 14.34 | 2599 | 708 | 2.86 / 1183.99 | 2 | 4 |
4 | 13 | 1017.60 | 19 | 14.52 | 1810 | 499 | 3.36 / 1184.49 | 2 | 5 |
5 | 13 | 439.96 | 19 | 14.75 | 991 | 278 | 3.64 / 1184.77 | 2 | 4 |
6 | 8 | 0.72 | 170 | 14.88 | 359 | 908 | 4.54 / 1185.68 | 2 | 10 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 28 | 15.03 | 510 | 215 | 0.21 / 1176.82 | 2 | 2 |
2 | 7 | 2002.60 | 43 | 14.30 | 3131 | 1925 | 2.14 / 1178.75 | 2 | 3 |
3 | 13 | 1599.96 | 19 | 14.33 | 2614 | 712 | 2.85 / 1179.46 | 2 | 6 |
4 | 13 | 1030.16 | 19 | 14.51 | 1825 | 503 | 3.35 / 1179.96 | 2 | 5 |
5 | 13 | 455.28 | 19 | 14.76 | 1006 | 282 | 3.64 / 1180.24 | 2 | 5 |
6 | 8 | -0.16 | 170 | 14.89 | 353 | 894 | 4.53 / 1181.14 | 2 | 12 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 29 | 15.03 | 509 | 222 | 0.22 / 1172.13 | 2 | 2 |
2 | 7 | 2003.92 | 43 | 14.30 | 3142 | 1932 | 2.15 / 1174.06 | 2 | 2 |
3 | 13 | 1731.00 | 19 | 14.30 | 2778 | 755 | 2.91 / 1174.81 | 2 | 5 |
4 | 13 | 1020.56 | 19 | 14.52 | 1807 | 499 | 3.41 / 1175.31 | 2 | 4 |
5 | 13 | 466.16 | 19 | 14.75 | 1024 | 287 | 3.69 / 1175.60 | 2 | 4 |
6 | 8 | -0.08 | 170 | 14.89 | 356 | 901 | 4.60 / 1176.50 | 2 | 14 |
7 | 14 | -0.08 | 20 | 14.86 | 353 | 105 | 4.70 / 1176.61 | 2 | 12 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 29 | 14.82 | 517 | 222 | 0.22 / 1167.53 | 2 | 2 |
2 | 7 | 2003.32 | 43 | 14.30 | 3129 | 1924 | 2.15 / 1169.45 | 2 | 4 |
3 | 13 | 1721.60 | 19 | 14.31 | 2779 | 756 | 2.90 / 1170.21 | 2 | 3 |
4 | 13 | 1126.72 | 19 | 14.47 | 1962 | 539 | 3.44 / 1170.75 | 2 | 7 |
5 | 13 | 403.00 | 19 | 14.78 | 935 | 263 | 3.70 / 1171.01 | 2 | 4 |
6 | 8 | 0.44 | 170 | 14.89 | 353 | 894 | 4.60 / 1171.91 | 2 | 8 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 28 | 14.84 | 506 | 210 | 0.21 / 1162.73 | 2 | 2 |
2 | 3 | 1018.88 | 1 | 15.09 | 1866 | 28 | 0.24 / 1162.75 | 2 | 2 |
3 | 7 | 2002.88 | 43 | 14.30 | 3130 | 1925 | 2.16 / 1164.68 | 2 | 2 |
4 | 13 | 1716.56 | 19 | 14.30 | 2759 | 750 | 2.91 / 1165.43 | 2 | 3 |
5 | 13 | 1149.76 | 19 | 14.46 | 1990 | 547 | 3.46 / 1165.97 | 2 | 6 |
6 | 13 | 563.52 | 19 | 14.70 | 1148 | 321 | 3.78 / 1166.30 | 2 | 5 |
7 | 13 | 11.84 | 19 | 14.94 | 390 | 111 | 3.89 / 1166.41 | 2 | 4 |
8 | 8 | 0.16 | 170 | 14.87 | 357 | 902 | 4.79 / 1167.31 | 2 | 14 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 30 | 14.83 | 520 | 231 | 0.23 / 1158.11 | 2 | 2 |
2 | 3 | 969.20 | -1 | 15.39 | 0 | 0 | 0.00 / 1158.11 | 2 | 2 |
3 | 7 | 2006.72 | 43 | 14.30 | 3138 | 1930 | 2.16 / 1160.04 | 2 | 3 |
4 | 13 | 1588.88 | 19 | 14.33 | 2594 | 706 | 2.87 / 1160.74 | 2 | 4 |
5 | 13 | 1156.04 | 19 | 14.45 | 1997 | 548 | 3.42 / 1161.29 | 2 | 3 |
6 | 13 | 545.88 | 19 | 14.71 | 1131 | 316 | 3.73 / 1161.61 | 2 | 6 |
7 | 8 | 0.00 | 170 | 14.89 | 359 | 909 | 4.64 / 1162.51 | 2 | 10 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 29 | 14.84 | 506 | 218 | 0.22 / 1153.36 | 2 | 2 |
2 | 3 | 1024.52 | 1 | 15.08 | 1858 | 28 | 0.25 / 1153.39 | 2 | 2 |
3 | 7 | 2005.00 | 43 | 14.29 | 3142 | 1931 | 2.18 / 1155.32 | 2 | 3 |
4 | 13 | 1733.76 | 19 | 14.30 | 2787 | 757 | 2.93 / 1156.08 | 2 | 4 |
5 | 13 | 1019.08 | 19 | 14.53 | 1808 | 499 | 3.43 / 1156.58 | 2 | 5 |
6 | 13 | 439.60 | 19 | 14.76 | 980 | 275 | 3.71 / 1156.85 | 2 | 4 |
7 | 13 | 69.52 | 19 | 14.91 | 469 | 133 | 3.84 / 1156.99 | 2 | 4 |
8 | 8 | 0.16 | 170 | 14.87 | 351 | 887 | 4.73 / 1157.87 | 2 | 12 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 27 | 14.99 | 509 | 206 | 0.21 / 1148.67 | 2 | 2 |
2 | 10 | 1020.48 | 3 | 14.88 | 1817 | 81 | 0.29 / 1148.76 | 2 | 4 |
3 | 7 | 2008.92 | 43 | 14.29 | 3142 | 1931 | 2.22 / 1150.69 | 4 | 2 |
4 | 13 | 1891.32 | 19 | 14.25 | 2989 | 809 | 3.03 / 1151.50 | 2 | 3 |
5 | 13 | 1033.56 | 19 | 14.52 | 1828 | 504 | 3.53 / 1152.00 | 2 | 6 |
6 | 13 | 362.12 | 19 | 14.79 | 878 | 247 | 3.78 / 1152.25 | 2 | 4 |
7 | 8 | 0.04 | 170 | 14.88 | 356 | 901 | 4.68 / 1153.15 | 2 | 10 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 28 | 14.83 | 508 | 211 | 0.21 / 1143.82 | 2 | 2 |
2 | 3 | 971.24 | -1 | 15.38 | 0 | 0 | 0.00 / 1143.82 | 2 | 2 |
3 | 7 | 2008.24 | 43 | 14.28 | 3142 | 1929 | 2.14 / 1145.75 | 2 | 3 |
4 | 13 | 1742.88 | 19 | 14.28 | 2791 | 757 | 2.90 / 1146.51 | 2 | 4 |
5 | 13 | 1139.96 | 19 | 14.47 | 1980 | 544 | 3.44 / 1147.05 | 2 | 6 |
6 | 13 | 688.28 | 19 | 14.64 | 1329 | 370 | 3.81 / 1147.42 | 2 | 6 |
7 | 13 | 24.32 | 19 | 14.92 | 419 | 119 | 3.93 / 1147.54 | 2 | 4 |
8 | 8 | 0.04 | 170 | 14.86 | 367 | 927 | 4.86 / 1148.47 | 2 | 13 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 28 | 14.89 | 513 | 214 | 0.21 / 1139.17 | 2 | 2 |
2 | 7 | 2010.48 | 43 | 14.27 | 3136 | 1924 | 2.14 / 1141.10 | 2 | 2 |
3 | 13 | 1898.08 | 19 | 14.24 | 3003 | 812 | 2.95 / 1141.91 | 2 | 2 |
4 | 13 | 1275.92 | 19 | 14.40 | 2167 | 593 | 3.54 / 1142.50 | 2 | 7 |
5 | 13 | 246.64 | 19 | 14.84 | 722 | 204 | 3.75 / 1142.71 | 2 | 4 |
6 | 8 | 0.04 | 170 | 14.88 | 358 | 906 | 4.65 / 1143.61 | 2 | 8 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 28 | 14.83 | 500 | 208 | 0.21 / 1134.30 | 2 | 2 |
2 | 10 | 1026.92 | 3 | 14.80 | 1826 | 81 | 0.29 / 1134.38 | 2 | 5 |
3 | 3 | 930.24 | -1 | 15.35 | 0 | 0 | 0.08 / 1134.38 | 2 | 5 |
4 | 3 | 934.16 | -1 | 15.38 | 0 | 0 | 0.08 / 1134.38 | 2 | 5 |
5 | 7 | 2006.44 | 43 | 14.29 | 3129 | 1923 | 2.21 / 1136.31 | 5 | 2 |
6 | 13 | 1461.28 | 19 | 14.37 | 2421 | 661 | 2.87 / 1136.97 | 2 | 4 |
7 | 13 | 1329.84 | 19 | 14.36 | 2238 | 611 | 3.48 / 1137.58 | 2 | 6 |
8 | 13 | 527.88 | 19 | 14.72 | 1090 | 305 | 3.79 / 1137.88 | 2 | 4 |
9 | 13 | 22.12 | 19 | 14.93 | 385 | 109 | 3.90 / 1137.99 | 2 | 4 |
10 | 8 | -0.08 | 170 | 14.87 | 341 | 862 | 4.76 / 1138.86 | 2 | 19 |
11 | 14 | -0.08 | 20 | 14.85 | 347 | 103 | 4.86 / 1138.96 | 2 | 11 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 28 | 14.84 | 492 | 204 | 0.20 / 1129.81 | 2 | 2 |
2 | 3 | 1020.64 | 1 | 15.04 | 1849 | 28 | 0.23 / 1129.84 | 2 | 2 |
3 | 7 | 2003.00 | 43 | 14.27 | 3144 | 1929 | 2.16 / 1131.77 | 2 | 2 |
4 | 13 | 1452.84 | 19 | 14.36 | 2412 | 658 | 2.82 / 1132.43 | 2 | 7 |
5 | 13 | 1035.12 | 19 | 14.50 | 1833 | 505 | 3.32 / 1132.93 | 2 | 5 |
6 | 13 | 444.52 | 19 | 14.74 | 986 | 276 | 3.60 / 1133.21 | 2 | 4 |
7 | 8 | 0.20 | 170 | 14.88 | 350 | 885 | 4.49 / 1134.10 | 2 | 8 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 29 | 15.02 | 511 | 223 | 0.22 / 1125.24 | 2 | 2 |
2 | 3 | 970.24 | -1 | 15.40 | 0 | 0 | 0.00 / 1125.24 | 2 | 2 |
3 | 7 | 2002.36 | 43 | 14.28 | 3135 | 1925 | 2.15 / 1127.16 | 2 | 2 |
4 | 13 | 1602.80 | 19 | 14.32 | 2614 | 711 | 2.86 / 1127.87 | 2 | 3 |
5 | 13 | 903.44 | 19 | 14.57 | 1655 | 458 | 3.32 / 1128.33 | 2 | 7 |
6 | 13 | 479.20 | 19 | 14.73 | 1046 | 293 | 3.61 / 1128.62 | 2 | 4 |
7 | 13 | 37.76 | 19 | 14.92 | 417 | 118 | 3.73 / 1128.74 | 2 | 3 |
8 | 8 | -0.04 | 170 | 14.87 | 344 | 870 | 4.60 / 1129.61 | 2 | 11 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 29 | 14.84 | 506 | 218 | 0.22 / 1120.59 | 2 | 2 |
2 | 7 | 2005.60 | 43 | 14.28 | 3141 | 1929 | 2.15 / 1122.52 | 2 | 3 |
3 | 13 | 1590.96 | 19 | 14.32 | 2590 | 705 | 2.85 / 1123.23 | 2 | 4 |
4 | 13 | 1045.52 | 19 | 14.50 | 1850 | 510 | 3.36 / 1123.74 | 2 | 5 |
5 | 13 | 472.64 | 19 | 14.73 | 1037 | 290 | 3.65 / 1124.03 | 2 | 4 |
6 | 13 | 51.76 | 19 | 14.92 | 430 | 122 | 3.77 / 1124.15 | 2 | 4 |
7 | 8 | 0.00 | 170 | 14.88 | 342 | 865 | 4.64 / 1125.01 | 2 | 16 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 29 | 15.04 | 512 | 223 | 0.22 / 1116.02 | 2 | 2 |
2 | 7 | 2010.92 | 43 | 14.27 | 3147 | 1931 | 2.15 / 1117.95 | 2 | 3 |
3 | 13 | 1495.32 | 19 | 14.35 | 2475 | 675 | 2.83 / 1118.62 | 2 | 3 |
4 | 13 | 1089.84 | 19 | 14.48 | 1909 | 525 | 3.35 / 1119.15 | 2 | 6 |
5 | 13 | 658.20 | 19 | 14.65 | 1291 | 359 | 3.71 / 1119.51 | 2 | 5 |
6 | 8 | 0.20 | 170 | 14.89 | 343 | 868 | 4.58 / 1120.37 | 2 | 11 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 27 | 14.97 | 517 | 209 | 0.21 / 1111.36 | 2 | 2 |
2 | 3 | 1063.48 | 2 | 14.90 | 1893 | 56 | 0.27 / 1111.42 | 2 | 4 |
3 | 7 | 2006.20 | 43 | 14.29 | 3149 | 1935 | 2.20 / 1113.35 | 2 | 2 |
4 | 13 | 1739.52 | 19 | 14.29 | 2789 | 757 | 2.96 / 1114.11 | 2 | 3 |
5 | 13 | 1161.60 | 19 | 14.46 | 2001 | 550 | 3.51 / 1114.66 | 2 | 5 |
6 | 13 | 446.48 | 19 | 14.77 | 1001 | 281 | 3.79 / 1114.94 | 2 | 3 |
7 | 8 | 0.40 | 170 | 14.90 | 337 | 854 | 4.64 / 1115.79 | 2 | 21 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 28 | 14.99 | 518 | 217 | 0.22 / 1106.74 | 2 | 2 |
2 | 3 | 973.28 | -1 | 15.37 | 0 | 0 | 0.00 / 1106.74 | 2 | 2 |
3 | 7 | 2009.44 | 43 | 14.27 | 3146 | 1930 | 2.15 / 1108.67 | 2 | 2 |
4 | 13 | 1472.44 | 19 | 14.36 | 2433 | 664 | 2.81 / 1109.34 | 2 | 6 |
5 | 13 | 1048.04 | 19 | 14.49 | 1849 | 509 | 3.32 / 1109.85 | 2 | 7 |
6 | 13 | 463.88 | 19 | 14.72 | 1017 | 284 | 3.61 / 1110.13 | 2 | 4 |
7 | 13 | 37.68 | 19 | 14.89 | 431 | 122 | 3.73 / 1110.25 | 2 | 3 |
8 | 8 | -0.04 | 170 | 14.83 | 356 | 898 | 4.62 / 1111.15 | 2 | 9 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 28 | 14.99 | 514 | 216 | 0.22 / 1102.17 | 2 | 2 |
2 | 7 | 2006.16 | 43 | 14.27 | 3140 | 1927 | 2.14 / 1104.09 | 2 | 3 |
3 | 13 | 1734.20 | 19 | 14.28 | 2782 | 755 | 2.90 / 1104.85 | 2 | 3 |
4 | 13 | 1009.32 | 19 | 14.51 | 1792 | 494 | 3.39 / 1105.34 | 2 | 5 |
5 | 13 | 444.12 | 19 | 14.72 | 993 | 278 | 3.67 / 1105.62 | 2 | 4 |
6 | 8 | 0.00 | 170 | 14.85 | 359 | 906 | 4.58 / 1106.53 | 2 | 10 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 29 | 14.81 | 507 | 218 | 0.22 / 1097.65 | 2 | 2 |
2 | 7 | 2007.08 | 43 | 14.28 | 3143 | 1930 | 2.15 / 1099.58 | 2 | 3 |
3 | 13 | 1604.00 | 19 | 14.32 | 2615 | 711 | 2.86 / 1100.29 | 2 | 4 |
4 | 13 | 1033.52 | 19 | 14.50 | 1821 | 502 | 3.36 / 1100.79 | 2 | 6 |
5 | 13 | 451.56 | 19 | 14.72 | 991 | 277 | 3.64 / 1101.07 | 2 | 4 |
6 | 8 | 0.44 | 170 | 14.86 | 348 | 879 | 4.52 / 1101.95 | 2 | 14 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 28 | 14.81 | 505 | 209 | 0.21 / 1093.05 | 2 | 2 |
2 | 3 | 1023.20 | 1 | 15.00 | 1843 | 28 | 0.24 / 1093.08 | 2 | 2 |
3 | 7 | 2003.56 | 43 | 14.27 | 3148 | 1932 | 2.17 / 1095.01 | 2 | 3 |
4 | 13 | 1734.36 | 19 | 14.28 | 2801 | 760 | 2.93 / 1095.77 | 2 | 5 |
5 | 13 | 1026.40 | 19 | 14.50 | 1819 | 501 | 3.43 / 1096.27 | 2 | 3 |
6 | 13 | 453.24 | 19 | 14.72 | 999 | 279 | 3.71 / 1096.55 | 2 | 4 |
7 | 8 | -0.28 | 170 | 14.85 | 349 | 881 | 4.59 / 1097.43 | 2 | 12 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 28 | 15.00 | 503 | 211 | 0.21 / 1088.33 | 2 | 2 |
2 | 7 | 2005.52 | 44 | 14.27 | 3137 | 1970 | 2.18 / 1090.30 | 2 | 4 |
3 | 13 | 1733.04 | 19 | 14.27 | 2787 | 756 | 2.94 / 1091.06 | 2 | 4 |
4 | 13 | 1133.60 | 19 | 14.46 | 1966 | 540 | 3.48 / 1091.60 | 2 | 5 |
5 | 13 | 379.28 | 19 | 14.75 | 899 | 252 | 3.73 / 1091.85 | 2 | 4 |
6 | 13 | 22.32 | 19 | 14.90 | 394 | 112 | 3.84 / 1091.96 | 2 | 3 |
7 | 8 | 0.32 | 170 | 14.84 | 350 | 883 | 4.72 / 1092.84 | 2 | 8 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 28 | 14.99 | 523 | 220 | 0.22 / 1083.73 | 2 | 2 |
2 | 7 | 2003.44 | 43 | 14.28 | 3135 | 1925 | 2.14 / 1085.66 | 2 | 2 |
3 | 13 | 1715.52 | 19 | 14.29 | 2764 | 750 | 2.89 / 1086.41 | 2 | 5 |
4 | 13 | 1124.80 | 19 | 14.46 | 1951 | 536 | 3.43 / 1086.94 | 2 | 4 |
5 | 13 | 550.00 | 19 | 14.69 | 1136 | 317 | 3.75 / 1087.26 | 2 | 4 |
6 | 8 | 0.12 | 170 | 14.87 | 340 | 859 | 4.61 / 1088.12 | 2 | 8 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 28 | 15.00 | 507 | 213 | 0.21 / 1079.04 | 2 | 2 |
2 | 7 | 2002.44 | 44 | 14.27 | 3134 | 1968 | 2.18 / 1081.00 | 2 | 2 |
3 | 13 | 1591.84 | 19 | 14.32 | 2599 | 707 | 2.89 / 1081.71 | 2 | 5 |
4 | 13 | 1019.16 | 19 | 14.50 | 1809 | 498 | 3.39 / 1082.21 | 2 | 5 |
5 | 13 | 320.40 | 19 | 14.78 | 819 | 230 | 3.62 / 1082.44 | 2 | 4 |
6 | 13 | 35.28 | 19 | 14.90 | 408 | 116 | 3.73 / 1082.55 | 2 | 4 |
7 | 13 | 14.12 | 19 | 14.90 | 371 | 105 | 3.84 / 1082.66 | 2 | 4 |
8 | 8 | -0.12 | 170 | 14.84 | 338 | 853 | 4.69 / 1083.51 | 2 | 11 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 28 | 15.00 | 503 | 211 | 0.21 / 1074.39 | 2 | 2 |
2 | 7 | 2005.48 | 43 | 14.28 | 3140 | 1928 | 2.14 / 1076.31 | 2 | 2 |
3 | 13 | 1588.68 | 19 | 14.32 | 2603 | 708 | 2.85 / 1077.02 | 2 | 3 |
4 | 13 | 1162.08 | 19 | 14.45 | 2006 | 551 | 3.40 / 1077.57 | 2 | 5 |
5 | 13 | 442.16 | 19 | 14.73 | 988 | 277 | 3.67 / 1077.85 | 2 | 5 |
6 | 13 | 27.20 | 19 | 14.90 | 391 | 111 | 3.79 / 1077.96 | 2 | 3 |
7 | 8 | 0.04 | 170 | 14.85 | 342 | 863 | 4.65 / 1078.82 | 2 | 11 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 28 | 14.82 | 514 | 213 | 0.21 / 1069.80 | 2 | 2 |
2 | 7 | 2003.28 | 43 | 14.28 | 3137 | 1926 | 2.14 / 1071.72 | 2 | 3 |
3 | 13 | 1589.68 | 19 | 14.32 | 2591 | 705 | 2.84 / 1072.43 | 2 | 4 |
4 | 13 | 1029.24 | 19 | 14.49 | 1815 | 500 | 3.34 / 1072.93 | 2 | 7 |
5 | 13 | 458.00 | 19 | 14.72 | 1007 | 282 | 3.63 / 1073.21 | 2 | 4 |
6 | 13 | 15.04 | 19 | 14.91 | 373 | 106 | 3.73 / 1073.31 | 2 | 4 |
7 | 8 | 0.20 | 170 | 14.85 | 341 | 861 | 4.59 / 1074.17 | 2 | 8 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 28 | 14.81 | 514 | 213 | 0.21 / 1065.20 | 2 | 2 |
2 | 7 | 2002.08 | 43 | 14.29 | 3128 | 1922 | 2.14 / 1067.12 | 2 | 3 |
3 | 13 | 1588.48 | 19 | 14.33 | 2587 | 704 | 2.84 / 1067.82 | 2 | 4 |
4 | 13 | 1032.44 | 19 | 14.49 | 1828 | 503 | 3.34 / 1068.33 | 2 | 4 |
5 | 13 | 455.84 | 19 | 14.72 | 1004 | 281 | 3.62 / 1068.61 | 2 | 4 |
6 | 13 | 5.48 | 19 | 14.91 | 364 | 103 | 3.73 / 1068.71 | 2 | 3 |
7 | 8 | -0.28 | 170 | 14.85 | 345 | 871 | 4.60 / 1069.58 | 2 | 14 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 28 | 14.82 | 498 | 207 | 0.21 / 1060.65 | 2 | 2 |
2 | 7 | 2002.04 | 43 | 14.28 | 3132 | 1923 | 2.13 / 1062.57 | 2 | 2 |
3 | 13 | 1597.84 | 19 | 14.32 | 2612 | 711 | 2.84 / 1063.28 | 2 | 5 |
4 | 13 | 1032.60 | 19 | 14.49 | 1821 | 501 | 3.34 / 1063.79 | 2 | 5 |
5 | 13 | 592.24 | 19 | 14.66 | 1186 | 330 | 3.67 / 1064.12 | 2 | 4 |
6 | 8 | 0.24 | 170 | 14.85 | 344 | 868 | 4.54 / 1064.98 | 2 | 9 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 28 | 15.02 | 483 | 203 | 0.20 / 1055.93 | 2 | 2 |
2 | 7 | 2006.16 | 44 | 14.27 | 3133 | 1967 | 2.17 / 1057.90 | 2 | 2 |
3 | 13 | 1593.08 | 19 | 14.32 | 2597 | 707 | 2.88 / 1058.60 | 2 | 4 |
4 | 13 | 1019.56 | 19 | 14.49 | 1807 | 497 | 3.37 / 1059.10 | 2 | 4 |
5 | 13 | 435.12 | 19 | 14.73 | 977 | 273 | 3.65 / 1059.38 | 2 | 3 |
6 | 13 | 30.92 | 19 | 14.90 | 393 | 111 | 3.76 / 1059.49 | 2 | 3 |
7 | 8 | 0.20 | 170 | 14.85 | 339 | 856 | 4.61 / 1060.34 | 2 | 9 |
8 | 14 | 0.20 | 20 | 14.82 | 341 | 101 | 4.72 / 1060.44 | 2 | 16 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 29 | 15.01 | 489 | 213 | 0.21 / 1051.30 | 2 | 2 |
2 | 7 | 2003.40 | 43 | 14.28 | 3133 | 1924 | 2.14 / 1053.22 | 2 | 3 |
3 | 13 | 1605.64 | 19 | 14.32 | 2628 | 715 | 2.85 / 1053.94 | 2 | 4 |
4 | 13 | 1175.36 | 19 | 14.44 | 2017 | 553 | 3.41 / 1054.49 | 2 | 7 |
5 | 13 | 439.00 | 19 | 14.73 | 977 | 273 | 3.68 / 1054.77 | 2 | 4 |
6 | 13 | 64.80 | 19 | 14.89 | 441 | 125 | 3.80 / 1054.89 | 2 | 4 |
7 | 8 | 0.04 | 170 | 14.86 | 331 | 836 | 4.64 / 1055.73 | 2 | 14 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 29 | 14.84 | 493 | 212 | 0.21 / 1046.74 | 2 | 2 |
2 | 7 | 2006.96 | 44 | 14.29 | 3127 | 1966 | 2.18 / 1048.71 | 2 | 4 |
3 | 13 | 1599.44 | 19 | 14.32 | 2599 | 707 | 2.89 / 1049.42 | 2 | 5 |
4 | 13 | 1023.80 | 19 | 14.50 | 1810 | 499 | 3.38 / 1049.91 | 2 | 5 |
5 | 13 | 328.48 | 19 | 14.78 | 826 | 232 | 3.62 / 1050.15 | 2 | 4 |
6 | 13 | 17.52 | 19 | 14.91 | 371 | 105 | 3.72 / 1050.25 | 2 | 3 |
7 | 8 | -0.04 | 170 | 14.86 | 331 | 836 | 4.56 / 1051.09 | 2 | 15 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 29 | 14.84 | 491 | 211 | 0.21 / 1042.31 | 2 | 2 |
2 | 7 | 2005.32 | 43 | 14.29 | 3135 | 1926 | 2.14 / 1044.24 | 2 | 3 |
3 | 13 | 1597.96 | 19 | 14.32 | 2592 | 705 | 2.84 / 1044.94 | 2 | 6 |
4 | 13 | 1041.76 | 19 | 14.49 | 1839 | 506 | 3.35 / 1045.45 | 2 | 5 |
5 | 13 | 340.48 | 19 | 14.77 | 842 | 236 | 3.59 / 1045.69 | 2 | 4 |
6 | 8 | 0.12 | 170 | 14.87 | 334 | 844 | 4.43 / 1046.53 | 2 | 11 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 14.84 | 498 | 214 | 0.21 / 1037.88 | 2 | 2 |
2 | 7 | 2004.52 | 43 | 14.29 | 3138 | 1928 | 2.14 / 1039.81 | 2 | 3 |
3 | 13 | 1599.12 | 19 | 14.32 | 2600 | 707 | 2.85 / 1040.51 | 2 | 3 |
4 | 13 | 1044.40 | 19 | 14.49 | 1840 | 507 | 3.36 / 1041.02 | 2 | 5 |
5 | 13 | 348.80 | 19 | 14.77 | 851 | 239 | 3.60 / 1041.26 | 2 | 4 |
6 | 8 | -0.20 | 170 | 14.87 | 333 | 842 | 4.44 / 1042.10 | 2 | 11 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 28 | 14.83 | 503 | 209 | 0.21 / 1033.34 | 2 | 2 |
2 | 7 | 2008.80 | 43 | 14.29 | 3130 | 1923 | 2.13 / 1035.27 | 2 | 4 |
3 | 13 | 1741.08 | 19 | 14.29 | 2788 | 757 | 2.89 / 1036.02 | 2 | 5 |
4 | 13 | 1033.92 | 19 | 14.49 | 1828 | 503 | 3.39 / 1036.53 | 2 | 4 |
5 | 13 | 467.92 | 19 | 14.72 | 1019 | 285 | 3.68 / 1036.81 | 2 | 4 |
6 | 8 | 0.28 | 170 | 14.87 | 337 | 852 | 4.53 / 1037.66 | 2 | 10 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 28 | 14.83 | 494 | 205 | 0.21 / 1028.91 | 2 | 2 |
2 | 7 | 2004.76 | 44 | 14.29 | 3138 | 1973 | 2.18 / 1030.89 | 2 | 3 |
3 | 13 | 1477.64 | 19 | 14.35 | 2457 | 670 | 2.85 / 1031.56 | 2 | 4 |
4 | 13 | 933.92 | 19 | 14.52 | 1694 | 467 | 3.32 / 1032.02 | 2 | 3 |
5 | 13 | 370.04 | 19 | 14.75 | 894 | 251 | 3.57 / 1032.27 | 2 | 3 |
6 | 8 | -0.04 | 170 | 14.86 | 341 | 861 | 4.43 / 1033.13 | 2 | 15 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 28 | 15.01 | 502 | 211 | 0.21 / 1024.37 | 2 | 2 |
2 | 7 | 2003.00 | 43 | 14.30 | 3130 | 1925 | 2.14 / 1026.29 | 2 | 4 |
3 | 13 | 1722.64 | 19 | 14.29 | 2776 | 754 | 2.89 / 1027.04 | 2 | 5 |
4 | 13 | 1140.84 | 19 | 14.45 | 1971 | 541 | 3.43 / 1027.58 | 2 | 6 |
5 | 13 | 421.84 | 19 | 14.74 | 960 | 269 | 3.70 / 1027.85 | 2 | 4 |
6 | 8 | 0.00 | 170 | 14.86 | 338 | 854 | 4.55 / 1028.71 | 2 | 10 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 28 | 14.84 | 501 | 208 | 0.21 / 1019.88 | 2 | 2 |
2 | 7 | 2006.44 | 43 | 14.29 | 3131 | 1924 | 2.13 / 1021.80 | 2 | 4 |
3 | 13 | 1594.92 | 19 | 14.32 | 2597 | 707 | 2.84 / 1022.51 | 2 | 3 |
4 | 13 | 1038.64 | 19 | 14.49 | 1828 | 503 | 3.34 / 1023.01 | 2 | 5 |
5 | 13 | 461.52 | 19 | 14.71 | 1013 | 283 | 3.63 / 1023.30 | 2 | 3 |
6 | 8 | 0.20 | 170 | 14.86 | 340 | 859 | 4.48 / 1024.15 | 2 | 6 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 28 | 14.82 | 510 | 212 | 0.21 / 1015.38 | 2 | 2 |
2 | 7 | 2005.84 | 44 | 14.29 | 3137 | 1972 | 2.18 / 1017.35 | 2 | 3 |
3 | 13 | 1726.56 | 19 | 14.28 | 2781 | 755 | 2.94 / 1018.11 | 2 | 4 |
4 | 13 | 998.20 | 19 | 14.50 | 1774 | 489 | 3.43 / 1018.60 | 2 | 5 |
5 | 13 | 298.72 | 19 | 14.79 | 786 | 221 | 3.65 / 1018.82 | 2 | 5 |
6 | 8 | -0.08 | 170 | 14.86 | 338 | 854 | 4.50 / 1019.67 | 2 | 8 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 29 | 14.92 | 500 | 216 | 0.22 / 1010.87 | 2 | 2 |
2 | 7 | 2006.12 | 43 | 14.29 | 3134 | 1926 | 2.14 / 1012.80 | 2 | 3 |
3 | 13 | 1601.48 | 19 | 14.32 | 2607 | 709 | 2.85 / 1013.51 | 2 | 6 |
4 | 13 | 1042.04 | 19 | 14.49 | 1841 | 507 | 3.36 / 1014.01 | 2 | 7 |
5 | 13 | 465.28 | 19 | 14.71 | 1022 | 286 | 3.64 / 1014.30 | 2 | 4 |
6 | 8 | 0.16 | 170 | 14.86 | 344 | 869 | 4.51 / 1015.17 | 2 | 9 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 29 | 14.82 | 500 | 215 | 0.21 / 1006.43 | 2 | 2 |
2 | 7 | 2003.32 | 43 | 14.30 | 3130 | 1925 | 2.14 / 1008.35 | 2 | 4 |
3 | 13 | 1596.12 | 19 | 14.33 | 2600 | 708 | 2.85 / 1009.06 | 2 | 3 |
4 | 13 | 1034.60 | 19 | 14.48 | 1821 | 501 | 3.35 / 1009.56 | 2 | 5 |
5 | 13 | 333.04 | 19 | 14.77 | 833 | 234 | 3.58 / 1009.80 | 2 | 4 |
6 | 8 | 0.12 | 170 | 14.86 | 340 | 859 | 4.44 / 1010.66 | 2 | 10 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 29 | 14.82 | 505 | 217 | 0.22 / 1001.86 | 2 | 2 |
2 | 7 | 2005.32 | 43 | 14.30 | 3142 | 1932 | 2.15 / 1003.79 | 2 | 3 |
3 | 13 | 1725.80 | 19 | 14.30 | 2771 | 753 | 2.90 / 1004.54 | 2 | 4 |
4 | 13 | 1133.00 | 19 | 14.45 | 1968 | 540 | 3.44 / 1005.08 | 2 | 5 |
5 | 13 | 414.60 | 19 | 14.73 | 955 | 267 | 3.71 / 1005.35 | 2 | 4 |
6 | 8 | 0.00 | 170 | 14.86 | 342 | 864 | 4.57 / 1006.21 | 2 | 10 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 29 | 14.81 | 516 | 222 | 0.22 / 997.35 | 2 | 2 |
2 | 7 | 2006.24 | 43 | 14.30 | 3138 | 1930 | 2.15 / 999.28 | 2 | 4 |
3 | 13 | 1590.84 | 19 | 14.32 | 2597 | 707 | 2.86 / 999.99 | 2 | 5 |
4 | 13 | 1027.48 | 19 | 14.49 | 1827 | 503 | 3.36 / 1000.49 | 2 | 4 |
5 | 13 | 457.64 | 19 | 14.71 | 1013 | 283 | 3.64 / 1000.78 | 2 | 4 |
6 | 8 | -0.04 | 170 | 14.86 | 342 | 864 | 4.51 / 1001.64 | 2 | 9 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 29 | 14.82 | 510 | 219 | 0.22 / 992.82 | 2 | 2 |
2 | 7 | 2008.60 | 43 | 14.30 | 3135 | 1928 | 2.15 / 994.75 | 2 | 3 |
3 | 13 | 1482.64 | 19 | 14.36 | 2447 | 668 | 2.81 / 995.42 | 2 | 6 |
4 | 13 | 1072.88 | 19 | 14.46 | 1873 | 515 | 3.33 / 995.93 | 2 | 5 |
5 | 13 | 362.48 | 19 | 14.75 | 874 | 245 | 3.57 / 996.18 | 2 | 4 |
6 | 13 | 20.84 | 19 | 14.90 | 377 | 107 | 3.68 / 996.28 | 2 | 3 |
7 | 8 | 0.20 | 170 | 14.85 | 336 | 848 | 4.53 / 997.13 | 2 | 10 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 28 | 14.82 | 509 | 211 | 0.21 / 988.32 | 2 | 2 |
2 | 3 | 1024.84 | 1 | 15.01 | 1857 | 28 | 0.24 / 988.35 | 2 | 2 |
3 | 7 | 2003.48 | 44 | 14.30 | 3143 | 1978 | 2.22 / 990.33 | 2 | 2 |
4 | 13 | 1584.36 | 19 | 14.32 | 2578 | 701 | 2.92 / 991.03 | 2 | 5 |
5 | 13 | 899.32 | 19 | 14.54 | 1643 | 454 | 3.37 / 991.48 | 2 | 4 |
6 | 13 | 342.12 | 19 | 14.76 | 860 | 241 | 3.61 / 991.72 | 2 | 4 |
7 | 8 | -0.12 | 170 | 14.86 | 348 | 879 | 4.49 / 992.60 | 2 | 10 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 28 | 15.00 | 513 | 215 | 0.22 / 983.73 | 2 | 2 |
2 | 7 | 2003.96 | 43 | 14.30 | 3135 | 1928 | 2.14 / 985.65 | 2 | 3 |
3 | 13 | 1727.60 | 19 | 14.29 | 2786 | 756 | 2.90 / 986.41 | 2 | 4 |
4 | 13 | 1138.20 | 19 | 14.45 | 1977 | 543 | 3.44 / 986.95 | 2 | 7 |
5 | 13 | 412.40 | 19 | 14.73 | 959 | 268 | 3.71 / 987.22 | 2 | 4 |
6 | 8 | 0.36 | 170 | 14.86 | 352 | 889 | 4.60 / 988.11 | 2 | 16 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 28 | 14.99 | 516 | 217 | 0.22 / 979.17 | 2 | 2 |
2 | 7 | 2007.92 | 43 | 14.30 | 3133 | 1926 | 2.14 / 981.10 | 2 | 3 |
3 | 13 | 1613.16 | 19 | 14.32 | 2626 | 714 | 2.86 / 981.82 | 2 | 3 |
4 | 13 | 1054.92 | 19 | 14.48 | 1853 | 510 | 3.37 / 982.32 | 2 | 5 |
5 | 13 | 488.64 | 19 | 14.70 | 1055 | 295 | 3.66 / 982.62 | 2 | 5 |
6 | 8 | 0.00 | 170 | 14.86 | 353 | 892 | 4.55 / 983.51 | 2 | 5 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 28 | 14.98 | 500 | 210 | 0.21 / 974.67 | 2 | 2 |
2 | 7 | 2005.16 | 43 | 14.30 | 3142 | 1932 | 2.14 / 976.60 | 2 | 2 |
3 | 13 | 1602.00 | 19 | 14.32 | 2599 | 707 | 2.85 / 977.31 | 2 | 6 |
4 | 13 | 1031.88 | 19 | 14.48 | 1826 | 502 | 3.35 / 977.81 | 2 | 7 |
5 | 13 | 460.36 | 19 | 14.70 | 1006 | 281 | 3.63 / 978.09 | 2 | 4 |
6 | 8 | 0.12 | 170 | 14.85 | 343 | 866 | 4.50 / 978.96 | 2 | 14 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 28 | 14.82 | 494 | 205 | 0.20 / 970.15 | 2 | 2 |
2 | 7 | 2005.08 | 43 | 14.30 | 3135 | 1928 | 2.13 / 972.08 | 2 | 3 |
3 | 13 | 1584.72 | 19 | 14.33 | 2588 | 705 | 2.84 / 972.78 | 2 | 4 |
4 | 13 | 1157.28 | 19 | 14.43 | 2001 | 549 | 3.39 / 973.33 | 2 | 4 |
5 | 13 | 423.56 | 19 | 14.72 | 953 | 267 | 3.65 / 973.60 | 2 | 3 |
6 | 8 | 0.04 | 170 | 14.85 | 341 | 861 | 4.51 / 974.46 | 2 | 9 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 28 | 15.00 | 496 | 208 | 0.21 / 965.55 | 2 | 2 |
2 | 7 | 2007.28 | 43 | 14.30 | 3137 | 1929 | 2.14 / 967.48 | 2 | 3 |
3 | 13 | 1726.36 | 19 | 14.29 | 2770 | 752 | 2.89 / 968.23 | 2 | 4 |
4 | 13 | 1142.96 | 19 | 14.44 | 1979 | 543 | 3.43 / 968.77 | 2 | 7 |
5 | 13 | 548.68 | 19 | 14.67 | 1133 | 316 | 3.75 / 969.09 | 2 | 4 |
6 | 8 | 0.44 | 170 | 14.86 | 340 | 859 | 4.61 / 969.95 | 2 | 8 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 28 | 15.00 | 502 | 211 | 0.21 / 961.04 | 2 | 2 |
2 | 7 | 2008.12 | 43 | 14.30 | 3144 | 1933 | 2.14 / 962.97 | 2 | 2 |
3 | 13 | 1603.44 | 19 | 14.32 | 2624 | 714 | 2.86 / 963.69 | 2 | 5 |
4 | 13 | 1037.20 | 19 | 14.48 | 1832 | 504 | 3.36 / 964.19 | 2 | 3 |
5 | 13 | 461.84 | 19 | 14.71 | 1015 | 284 | 3.65 / 964.48 | 2 | 3 |
6 | 8 | 0.16 | 170 | 14.85 | 342 | 863 | 4.51 / 965.34 | 2 | 11 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 29 | 15.01 | 502 | 219 | 0.22 / 956.42 | 2 | 2 |
2 | 7 | 2005.76 | 43 | 14.30 | 3137 | 1929 | 2.15 / 958.35 | 2 | 2 |
3 | 13 | 1594.44 | 19 | 14.33 | 2597 | 707 | 2.85 / 959.06 | 2 | 4 |
4 | 13 | 1036.36 | 19 | 14.48 | 1832 | 504 | 3.36 / 959.56 | 2 | 4 |
5 | 13 | 462.00 | 19 | 14.71 | 1018 | 285 | 3.64 / 959.85 | 2 | 4 |
6 | 13 | 66.36 | 19 | 14.88 | 449 | 127 | 3.77 / 959.97 | 2 | 3 |
7 | 8 | -0.28 | 170 | 14.84 | 339 | 855 | 4.63 / 960.83 | 2 | 19 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 29 | 14.82 | 501 | 215 | 0.22 / 951.88 | 2 | 2 |
2 | 7 | 2004.76 | 43 | 14.30 | 3136 | 1928 | 2.14 / 953.81 | 2 | 3 |
3 | 13 | 1593.64 | 19 | 14.33 | 2584 | 704 | 2.85 / 954.51 | 2 | 5 |
4 | 13 | 1035.76 | 19 | 14.48 | 1824 | 502 | 3.35 / 955.02 | 2 | 4 |
5 | 13 | 336.60 | 19 | 14.77 | 836 | 235 | 3.58 / 955.25 | 2 | 3 |
6 | 13 | 19.72 | 19 | 14.91 | 374 | 106 | 3.69 / 955.36 | 2 | 3 |
7 | 8 | -0.20 | 170 | 14.85 | 336 | 848 | 4.54 / 956.20 | 2 | 12 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 29 | 14.83 | 495 | 213 | 0.21 / 947.40 | 2 | 2 |
2 | 7 | 2008.16 | 43 | 14.30 | 3141 | 1931 | 2.14 / 949.33 | 2 | 2 |
3 | 13 | 1601.32 | 19 | 14.32 | 2608 | 710 | 2.85 / 950.04 | 2 | 3 |
4 | 13 | 1035.12 | 19 | 14.49 | 1824 | 502 | 3.36 / 950.54 | 2 | 7 |
5 | 13 | 456.40 | 19 | 14.71 | 1003 | 280 | 3.64 / 950.82 | 2 | 3 |
6 | 8 | -0.04 | 170 | 14.86 | 335 | 846 | 4.48 / 951.67 | 2 | 12 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 29 | 14.83 | 488 | 210 | 0.21 / 942.94 | 2 | 2 |
2 | 7 | 2002.60 | 43 | 14.31 | 3128 | 1925 | 2.13 / 944.87 | 2 | 2 |
3 | 13 | 1590.00 | 19 | 14.33 | 2597 | 707 | 2.84 / 945.58 | 2 | 3 |
4 | 13 | 1043.52 | 19 | 14.48 | 1840 | 506 | 3.35 / 946.08 | 2 | 5 |
5 | 13 | 465.24 | 19 | 14.71 | 1015 | 284 | 3.63 / 946.37 | 2 | 4 |
6 | 8 | 0.32 | 170 | 14.87 | 324 | 819 | 4.45 / 947.18 | 2 | 6 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 29 | 14.83 | 494 | 212 | 0.21 / 938.36 | 2 | 2 |
2 | 7 | 2004.20 | 43 | 14.31 | 3138 | 1931 | 2.14 / 940.29 | 2 | 3 |
3 | 13 | 1597.76 | 19 | 14.33 | 2609 | 710 | 2.85 / 941.00 | 2 | 5 |
4 | 13 | 1042.48 | 19 | 14.48 | 1835 | 505 | 3.36 / 941.51 | 2 | 6 |
5 | 13 | 469.88 | 19 | 14.72 | 1028 | 288 | 3.65 / 941.80 | 2 | 3 |
6 | 13 | 36.48 | 19 | 14.91 | 392 | 111 | 3.76 / 941.91 | 2 | 3 |
7 | 8 | 0.12 | 170 | 14.87 | 327 | 827 | 4.58 / 942.73 | 2 | 12 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 29 | 14.85 | 481 | 207 | 0.21 / 933.89 | 2 | 2 |
2 | 7 | 2002.68 | 43 | 14.31 | 3134 | 1928 | 2.14 / 935.81 | 2 | 3 |
3 | 13 | 1596.76 | 19 | 14.33 | 2605 | 709 | 2.84 / 936.52 | 2 | 5 |
4 | 13 | 1035.92 | 19 | 14.48 | 1831 | 504 | 3.35 / 937.03 | 2 | 3 |
5 | 13 | 454.24 | 19 | 14.72 | 1006 | 281 | 3.63 / 937.31 | 2 | 3 |
6 | 8 | 0.36 | 170 | 14.87 | 333 | 842 | 4.47 / 938.15 | 2 | 8 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 29 | 14.84 | 487 | 210 | 0.21 / 929.34 | 2 | 2 |
2 | 7 | 2004.64 | 43 | 14.31 | 3137 | 1930 | 2.14 / 931.27 | 2 | 3 |
3 | 13 | 1600.52 | 19 | 14.33 | 2608 | 710 | 2.85 / 931.98 | 2 | 4 |
4 | 13 | 1167.84 | 19 | 14.43 | 2019 | 554 | 3.40 / 932.53 | 2 | 4 |
5 | 13 | 322.48 | 19 | 14.80 | 805 | 226 | 3.63 / 932.76 | 2 | 3 |
6 | 13 | 18.76 | 19 | 14.93 | 364 | 103 | 3.73 / 932.86 | 2 | 2 |
7 | 8 | -0.28 | 170 | 14.88 | 324 | 820 | 4.55 / 933.68 | 2 | 12 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 30 | 15.01 | 489 | 220 | 0.22 / 924.82 | 2 | 2 |
2 | 7 | 2005.88 | 43 | 14.31 | 3133 | 1928 | 2.15 / 926.75 | 2 | 2 |
3 | 13 | 1595.68 | 19 | 14.33 | 2604 | 709 | 2.86 / 927.46 | 2 | 5 |
4 | 13 | 1163.68 | 19 | 14.43 | 2007 | 550 | 3.41 / 928.01 | 2 | 8 |
5 | 13 | 433.12 | 19 | 14.74 | 975 | 273 | 3.68 / 928.28 | 2 | 3 |
6 | 8 | 0.24 | 170 | 14.88 | 333 | 842 | 4.52 / 929.13 | 2 | 8 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 29 | 14.86 | 483 | 208 | 0.21 / 920.21 | 2 | 2 |
2 | 7 | 2006.44 | 43 | 14.31 | 3145 | 1935 | 2.14 / 922.14 | 2 | 3 |
3 | 13 | 1589.16 | 19 | 14.33 | 2604 | 709 | 2.85 / 922.85 | 2 | 3 |
4 | 13 | 1159.88 | 19 | 14.43 | 2012 | 552 | 3.40 / 923.40 | 2 | 4 |
5 | 13 | 441.48 | 19 | 14.74 | 976 | 273 | 3.68 / 923.68 | 2 | 3 |
6 | 13 | 13.28 | 19 | 14.92 | 356 | 101 | 3.78 / 923.78 | 2 | 2 |
7 | 8 | 0.08 | 170 | 14.87 | 326 | 824 | 4.60 / 924.60 | 2 | 9 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 29 | 15.00 | 483 | 210 | 0.21 / 915.61 | 2 | 2 |
2 | 7 | 2002.48 | 44 | 14.30 | 3140 | 1976 | 2.19 / 917.59 | 2 | 2 |
3 | 13 | 1721.64 | 19 | 14.29 | 2778 | 754 | 2.94 / 918.34 | 2 | 4 |
4 | 13 | 1267.60 | 19 | 14.39 | 2149 | 588 | 3.53 / 918.93 | 2 | 5 |
5 | 13 | 382.24 | 19 | 14.78 | 886 | 249 | 3.78 / 919.18 | 2 | 3 |
6 | 8 | 0.24 | 170 | 14.89 | 324 | 820 | 4.60 / 920.00 | 2 | 6 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 30 | 15.06 | 484 | 219 | 0.22 / 911.20 | 2 | 2 |
2 | 7 | 2004.92 | 43 | 14.31 | 3138 | 1931 | 2.15 / 913.14 | 2 | 2 |
3 | 13 | 1604.00 | 19 | 14.32 | 2610 | 710 | 2.86 / 913.85 | 2 | 4 |
4 | 13 | 1051.56 | 19 | 14.48 | 1854 | 510 | 3.37 / 914.36 | 2 | 6 |
5 | 13 | 345.80 | 19 | 14.80 | 838 | 236 | 3.61 / 914.59 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.89 | 321 | 813 | 4.42 / 915.40 | 2 | 8 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 30 | 14.92 | 474 | 212 | 0.21 / 906.46 | 2 | 2 |
2 | 7 | 2008.32 | 43 | 14.31 | 3144 | 1935 | 2.15 / 908.39 | 2 | 2 |
3 | 13 | 1732.28 | 19 | 14.29 | 2780 | 755 | 2.90 / 909.15 | 2 | 3 |
4 | 13 | 1151.44 | 19 | 14.44 | 1991 | 546 | 3.45 / 909.69 | 2 | 4 |
5 | 13 | 436.52 | 19 | 14.75 | 964 | 270 | 3.72 / 909.96 | 2 | 2 |
6 | 13 | 58.92 | 19 | 14.91 | 417 | 118 | 3.84 / 910.08 | 2 | 2 |
7 | 8 | 0.00 | 170 | 14.88 | 320 | 809 | 4.65 / 910.89 | 2 | 14 |
8 | 14 | 0.00 | 20 | 14.85 | 321 | 95 | 4.74 / 910.99 | 2 | 9 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 29 | 14.86 | 484 | 209 | 0.21 / 901.91 | 2 | 2 |
2 | 7 | 2004.40 | 43 | 14.31 | 3144 | 1935 | 2.14 / 903.84 | 2 | 2 |
3 | 13 | 1730.96 | 19 | 14.30 | 2780 | 755 | 2.90 / 904.60 | 2 | 3 |
4 | 13 | 1033.52 | 19 | 14.49 | 1821 | 501 | 3.40 / 905.10 | 2 | 6 |
5 | 13 | 333.36 | 19 | 14.80 | 814 | 229 | 3.63 / 905.33 | 2 | 2 |
6 | 13 | 37.96 | 19 | 14.93 | 382 | 108 | 3.74 / 905.44 | 2 | 2 |
7 | 8 | 0.20 | 170 | 14.88 | 319 | 807 | 4.54 / 906.25 | 2 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 29 | 14.86 | 484 | 209 | 0.21 / 897.42 | 2 | 2 |
2 | 7 | 2009.36 | 43 | 14.32 | 3148 | 1938 | 2.15 / 899.36 | 2 | 2 |
3 | 13 | 1612.00 | 19 | 14.32 | 2625 | 714 | 2.86 / 900.08 | 2 | 3 |
4 | 13 | 1054.48 | 19 | 14.47 | 1861 | 512 | 3.37 / 900.59 | 2 | 3 |
5 | 13 | 479.08 | 19 | 14.73 | 1035 | 290 | 3.66 / 900.88 | 2 | 3 |
6 | 8 | -0.04 | 170 | 14.89 | 325 | 823 | 4.49 / 901.70 | 2 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 29 | 14.95 | 486 | 211 | 0.21 / 892.90 | 2 | 2 |
2 | 7 | 2001.64 | 43 | 14.32 | 3140 | 1933 | 2.14 / 894.84 | 2 | 2 |
3 | 13 | 1727.40 | 19 | 14.31 | 2774 | 754 | 2.90 / 895.59 | 2 | 3 |
4 | 13 | 1139.60 | 19 | 14.44 | 1974 | 542 | 3.44 / 896.13 | 2 | 5 |
5 | 13 | 426.00 | 19 | 14.76 | 953 | 267 | 3.71 / 896.40 | 2 | 3 |
6 | 8 | 0.40 | 170 | 14.89 | 323 | 818 | 4.52 / 897.22 | 2 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 29 | 14.85 | 479 | 206 | 0.21 / 888.19 | 2 | 2 |
2 | 7 | 2002.32 | 43 | 14.32 | 3144 | 1936 | 2.14 / 890.13 | 2 | 2 |
3 | 13 | 1728.12 | 19 | 14.30 | 2791 | 758 | 2.90 / 890.88 | 2 | 3 |
4 | 13 | 1147.48 | 19 | 14.44 | 1989 | 546 | 3.45 / 891.43 | 2 | 3 |
5 | 13 | 562.48 | 19 | 14.68 | 1161 | 324 | 3.77 / 891.75 | 2 | 3 |
6 | 13 | 47.84 | 19 | 14.91 | 409 | 116 | 3.89 / 891.87 | 2 | 3 |
7 | 8 | 0.16 | 170 | 14.87 | 325 | 822 | 4.71 / 892.69 | 2 | 12 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 30 | 15.08 | 474 | 214 | 0.21 / 883.77 | 2 | 2 |
2 | 7 | 2004.08 | 43 | 14.31 | 3144 | 1935 | 2.15 / 885.71 | 2 | 2 |
3 | 13 | 1605.04 | 19 | 14.32 | 2613 | 711 | 2.86 / 886.42 | 2 | 3 |
4 | 13 | 1049.32 | 19 | 14.47 | 1850 | 509 | 3.37 / 886.93 | 2 | 5 |
5 | 13 | 338.00 | 19 | 14.79 | 829 | 233 | 3.60 / 887.16 | 2 | 3 |
6 | 8 | 0.28 | 170 | 14.88 | 325 | 822 | 4.42 / 887.98 | 2 | 6 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 29 | 14.85 | 482 | 208 | 0.21 / 879.23 | 2 | 2 |
2 | 7 | 2003.84 | 43 | 14.32 | 3144 | 1936 | 2.14 / 881.16 | 2 | 2 |
3 | 13 | 1729.64 | 19 | 14.30 | 2778 | 755 | 2.90 / 881.92 | 2 | 5 |
4 | 13 | 1161.68 | 19 | 14.43 | 1999 | 548 | 3.45 / 882.47 | 2 | 4 |
5 | 13 | 445.36 | 19 | 14.75 | 983 | 275 | 3.72 / 882.74 | 2 | 3 |
6 | 8 | 0.28 | 170 | 14.89 | 323 | 818 | 4.54 / 883.56 | 2 | 5 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 29 | 14.86 | 468 | 202 | 0.20 / 874.67 | 2 | 2 |
2 | 7 | 2002.44 | 43 | 14.32 | 3147 | 1938 | 2.14 / 876.61 | 2 | 2 |
3 | 13 | 1731.04 | 19 | 14.30 | 2789 | 758 | 2.90 / 877.37 | 2 | 3 |
4 | 13 | 1023.92 | 19 | 14.49 | 1815 | 500 | 3.40 / 877.87 | 2 | 2 |
5 | 13 | 321.64 | 19 | 14.81 | 805 | 227 | 3.62 / 878.09 | 2 | 2 |
6 | 13 | 34.40 | 19 | 14.92 | 386 | 109 | 3.73 / 878.20 | 2 | 2 |
7 | 8 | 0.08 | 170 | 14.88 | 323 | 817 | 4.55 / 879.02 | 2 | 11 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 30 | 15.03 | 465 | 210 | 0.21 / 870.24 | 2 | 2 |
2 | 7 | 2002.84 | 43 | 14.32 | 3138 | 1932 | 2.14 / 872.17 | 2 | 2 |
3 | 13 | 1600.88 | 19 | 14.32 | 2609 | 710 | 2.85 / 872.88 | 2 | 3 |
4 | 13 | 1173.04 | 19 | 14.42 | 2014 | 552 | 3.40 / 873.43 | 2 | 5 |
5 | 13 | 313.76 | 19 | 14.81 | 788 | 222 | 3.63 / 873.65 | 2 | 3 |
6 | 8 | 0.08 | 170 | 14.88 | 323 | 817 | 4.44 / 874.47 | 2 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 29 | 14.87 | 470 | 203 | 0.20 / 865.73 | 2 | 2 |
2 | 7 | 2004.40 | 43 | 14.32 | 3145 | 1937 | 2.14 / 867.67 | 2 | 2 |
3 | 13 | 1602.64 | 19 | 14.33 | 2616 | 712 | 2.85 / 868.38 | 2 | 4 |
4 | 13 | 1179.44 | 19 | 14.42 | 2038 | 558 | 3.41 / 868.94 | 2 | 6 |
5 | 13 | 442.32 | 19 | 14.75 | 982 | 275 | 3.69 / 869.21 | 2 | 3 |
6 | 8 | 0.04 | 170 | 14.88 | 323 | 817 | 4.50 / 870.03 | 2 | 9 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 29 | 14.86 | 462 | 199 | 0.20 / 861.29 | 2 | 2 |
2 | 7 | 2005.04 | 44 | 14.31 | 3145 | 1980 | 2.18 / 863.27 | 2 | 2 |
3 | 13 | 1591.24 | 19 | 14.33 | 2596 | 707 | 2.89 / 863.98 | 2 | 2 |
4 | 13 | 1035.08 | 19 | 14.48 | 1832 | 504 | 3.39 / 864.48 | 2 | 6 |
5 | 13 | 325.36 | 19 | 14.80 | 807 | 227 | 3.62 / 864.71 | 2 | 3 |
6 | 8 | -0.24 | 170 | 14.88 | 322 | 815 | 4.43 / 865.53 | 2 | 5 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 29 | 15.09 | 458 | 200 | 0.20 / 856.83 | 2 | 2 |
2 | 7 | 2003.04 | 43 | 14.32 | 3139 | 1933 | 2.13 / 858.77 | 2 | 2 |
3 | 13 | 1601.72 | 19 | 14.32 | 2603 | 708 | 2.84 / 859.47 | 2 | 3 |
4 | 13 | 1171.48 | 19 | 14.43 | 2015 | 552 | 3.39 / 860.03 | 2 | 3 |
5 | 13 | 439.24 | 19 | 14.75 | 965 | 270 | 3.66 / 860.30 | 2 | 2 |
6 | 8 | 0.40 | 170 | 14.89 | 315 | 797 | 4.46 / 861.09 | 2 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 29 | 15.08 | 472 | 206 | 0.21 / 852.39 | 2 | 2 |
2 | 7 | 2003.80 | 43 | 14.32 | 3134 | 1930 | 2.14 / 854.32 | 2 | 2 |
3 | 13 | 1594.92 | 19 | 14.33 | 2602 | 708 | 2.84 / 855.03 | 2 | 4 |
4 | 13 | 1052.52 | 19 | 14.47 | 1856 | 510 | 3.35 / 855.54 | 2 | 5 |
5 | 13 | 476.76 | 19 | 14.73 | 1019 | 285 | 3.64 / 855.82 | 2 | 3 |
6 | 8 | -0.04 | 170 | 14.88 | 320 | 809 | 4.45 / 856.63 | 2 | 5 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 29 | 14.86 | 459 | 198 | 0.20 / 847.82 | 2 | 2 |
2 | 7 | 2001.88 | 43 | 14.33 | 3148 | 1940 | 2.14 / 849.76 | 2 | 2 |
3 | 13 | 1728.12 | 19 | 14.31 | 2775 | 754 | 2.89 / 850.51 | 2 | 4 |
4 | 13 | 1145.80 | 19 | 14.44 | 1984 | 544 | 3.44 / 851.06 | 2 | 4 |
5 | 13 | 557.52 | 19 | 14.69 | 1137 | 317 | 3.75 / 851.37 | 2 | 2 |
6 | 8 | 0.16 | 170 | 14.88 | 320 | 809 | 4.56 / 852.18 | 2 | 6 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 29 | 15.08 | 467 | 204 | 0.20 / 843.39 | 2 | 2 |
2 | 7 | 2006.44 | 43 | 14.32 | 3150 | 1940 | 2.14 / 845.32 | 2 | 3 |
3 | 13 | 1736.04 | 19 | 14.30 | 2787 | 757 | 2.90 / 846.08 | 2 | 3 |
4 | 13 | 1032.84 | 19 | 14.48 | 1819 | 500 | 3.40 / 846.58 | 2 | 5 |
5 | 13 | 334.92 | 19 | 14.80 | 817 | 230 | 3.63 / 846.81 | 2 | 2 |
6 | 8 | 0.04 | 170 | 14.89 | 319 | 807 | 4.44 / 847.62 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 29 | 15.07 | 461 | 201 | 0.20 / 838.91 | 2 | 2 |
2 | 7 | 2004.44 | 44 | 14.32 | 3140 | 1978 | 2.18 / 840.89 | 2 | 3 |
3 | 13 | 1594.80 | 19 | 14.33 | 2596 | 707 | 2.89 / 841.59 | 2 | 4 |
4 | 13 | 1019.68 | 19 | 14.48 | 1808 | 497 | 3.38 / 842.09 | 2 | 5 |
5 | 13 | 445.64 | 19 | 14.74 | 986 | 276 | 3.66 / 842.37 | 2 | 3 |
6 | 8 | 0.12 | 170 | 14.88 | 322 | 815 | 4.47 / 843.18 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 29 | 15.06 | 467 | 204 | 0.20 / 834.43 | 2 | 2 |
2 | 7 | 2003.60 | 43 | 14.32 | 3145 | 1937 | 2.14 / 836.37 | 2 | 2 |
3 | 13 | 1595.20 | 19 | 14.34 | 2597 | 708 | 2.85 / 837.07 | 2 | 3 |
4 | 13 | 1166.96 | 19 | 14.42 | 2012 | 551 | 3.40 / 837.62 | 2 | 3 |
5 | 13 | 420.60 | 19 | 14.75 | 945 | 265 | 3.66 / 837.89 | 2 | 2 |
6 | 8 | 0.00 | 170 | 14.88 | 323 | 817 | 4.48 / 838.71 | 2 | 8 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 15.06 | 468 | 204 | 0.20 / 829.94 | 2 | 2 |
2 | 7 | 2002.60 | 43 | 14.33 | 3138 | 1934 | 2.14 / 831.88 | 2 | 2 |
3 | 13 | 1598.64 | 19 | 14.33 | 2594 | 706 | 2.84 / 832.58 | 2 | 3 |
4 | 13 | 1174.32 | 19 | 14.42 | 2018 | 553 | 3.40 / 833.13 | 2 | 3 |
5 | 13 | 457.04 | 19 | 14.74 | 995 | 279 | 3.68 / 833.41 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.88 | 321 | 812 | 4.49 / 834.22 | 2 | 6 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 29 | 15.06 | 475 | 207 | 0.21 / 825.48 | 2 | 2 |
2 | 7 | 2004.88 | 43 | 14.33 | 3141 | 1935 | 2.14 / 827.42 | 2 | 2 |
3 | 13 | 1599.88 | 19 | 14.33 | 2603 | 709 | 2.85 / 828.12 | 2 | 4 |
4 | 13 | 1047.12 | 19 | 14.48 | 1844 | 507 | 3.36 / 828.63 | 2 | 5 |
5 | 13 | 485.56 | 19 | 14.73 | 1031 | 289 | 3.65 / 828.92 | 2 | 3 |
6 | 8 | 0.28 | 170 | 14.88 | 323 | 817 | 4.46 / 829.74 | 2 | 7 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 29 | 15.06 | 471 | 206 | 0.21 / 820.93 | 2 | 2 |
2 | 7 | 2007.36 | 43 | 14.33 | 3143 | 1937 | 2.14 / 822.86 | 2 | 2 |
3 | 13 | 1728.80 | 19 | 14.31 | 2780 | 756 | 2.90 / 823.62 | 2 | 3 |
4 | 13 | 1157.44 | 19 | 14.44 | 1995 | 547 | 3.45 / 824.17 | 2 | 6 |
5 | 13 | 436.84 | 19 | 14.75 | 966 | 271 | 3.72 / 824.44 | 2 | 2 |
6 | 8 | 0.16 | 170 | 14.88 | 330 | 835 | 4.55 / 825.27 | 2 | 10 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 29 | 15.06 | 470 | 205 | 0.21 / 816.50 | 2 | 2 |
2 | 7 | 2009.28 | 43 | 14.33 | 3146 | 1939 | 2.14 / 818.43 | 2 | 3 |
3 | 13 | 1601.12 | 19 | 14.33 | 2600 | 708 | 2.85 / 819.14 | 2 | 5 |
4 | 13 | 1171.88 | 19 | 14.43 | 2016 | 553 | 3.40 / 819.70 | 2 | 4 |
5 | 13 | 303.04 | 19 | 14.81 | 770 | 217 | 3.62 / 819.91 | 2 | 2 |
6 | 8 | 0.24 | 170 | 14.88 | 320 | 809 | 4.43 / 820.72 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 29 | 14.85 | 498 | 214 | 0.21 / 812.05 | 2 | 2 |
2 | 7 | 2003.40 | 43 | 14.33 | 3146 | 1939 | 2.15 / 813.99 | 2 | 2 |
3 | 13 | 1594.80 | 19 | 14.34 | 2608 | 711 | 2.86 / 814.70 | 2 | 5 |
4 | 13 | 1167.00 | 19 | 14.42 | 2011 | 551 | 3.41 / 815.25 | 2 | 5 |
5 | 13 | 313.64 | 19 | 14.81 | 794 | 223 | 3.64 / 815.47 | 2 | 2 |
6 | 8 | -0.28 | 170 | 14.88 | 323 | 817 | 4.46 / 816.29 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 29 | 15.05 | 487 | 213 | 0.21 / 807.62 | 2 | 2 |
2 | 7 | 2003.44 | 43 | 14.33 | 3137 | 1933 | 2.15 / 809.55 | 2 | 2 |
3 | 13 | 1602.48 | 19 | 14.34 | 2609 | 711 | 2.86 / 810.26 | 2 | 3 |
4 | 13 | 1045.88 | 19 | 14.48 | 1845 | 508 | 3.36 / 810.77 | 2 | 4 |
5 | 13 | 336.56 | 19 | 14.80 | 829 | 233 | 3.60 / 811.00 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.88 | 330 | 835 | 4.43 / 811.84 | 2 | 10 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 29 | 15.06 | 492 | 215 | 0.21 / 803.10 | 2 | 2 |
2 | 7 | 2003.36 | 43 | 14.34 | 3142 | 1937 | 2.15 / 805.04 | 2 | 2 |
3 | 13 | 1603.80 | 19 | 14.34 | 2614 | 712 | 2.86 / 805.75 | 2 | 5 |
4 | 13 | 1174.68 | 19 | 14.42 | 2025 | 555 | 3.42 / 806.30 | 2 | 3 |
5 | 13 | 446.52 | 19 | 14.74 | 981 | 275 | 3.69 / 806.58 | 2 | 2 |
6 | 8 | 0.52 | 170 | 14.87 | 327 | 827 | 4.52 / 807.40 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 29 | 15.06 | 490 | 214 | 0.21 / 798.66 | 2 | 2 |
2 | 7 | 2005.76 | 43 | 14.33 | 3147 | 1939 | 2.15 / 800.60 | 2 | 2 |
3 | 13 | 1611.08 | 19 | 14.33 | 2620 | 713 | 2.87 / 801.32 | 2 | 4 |
4 | 13 | 1058.76 | 19 | 14.47 | 1862 | 512 | 3.38 / 801.83 | 2 | 4 |
5 | 13 | 346.76 | 19 | 14.79 | 835 | 235 | 3.61 / 802.06 | 2 | 2 |
6 | 8 | -0.36 | 170 | 14.88 | 324 | 820 | 4.43 / 802.88 | 2 | 15 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 29 | 14.83 | 482 | 207 | 0.21 / 794.14 | 2 | 2 |
2 | 7 | 2006.72 | 43 | 14.34 | 3141 | 1937 | 2.14 / 796.07 | 2 | 2 |
3 | 13 | 1736.88 | 19 | 14.31 | 2791 | 759 | 2.90 / 796.83 | 2 | 5 |
4 | 13 | 1024.12 | 19 | 14.49 | 1814 | 499 | 3.40 / 797.33 | 2 | 5 |
5 | 13 | 448.00 | 19 | 14.75 | 990 | 277 | 3.68 / 797.61 | 2 | 3 |
6 | 8 | 0.08 | 170 | 14.88 | 333 | 842 | 4.52 / 798.45 | 2 | 17 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 29 | 14.86 | 494 | 213 | 0.21 / 789.51 | 2 | 2 |
2 | 7 | 2005.40 | 43 | 14.34 | 3140 | 1936 | 2.15 / 791.45 | 2 | 2 |
3 | 13 | 1729.80 | 19 | 14.32 | 2780 | 756 | 2.91 / 792.21 | 2 | 2 |
4 | 13 | 1143.44 | 19 | 14.44 | 1993 | 547 | 3.45 / 792.75 | 2 | 4 |
5 | 13 | 296.16 | 19 | 14.82 | 782 | 220 | 3.67 / 792.97 | 2 | 2 |
6 | 13 | 72.28 | 19 | 14.91 | 445 | 126 | 3.80 / 793.10 | 2 | 2 |
7 | 8 | 0.12 | 170 | 14.88 | 328 | 830 | 4.63 / 793.93 | 2 | 10 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 29 | 14.93 | 483 | 209 | 0.21 / 784.99 | 2 | 2 |
2 | 7 | 2007.00 | 43 | 14.34 | 3146 | 1940 | 2.15 / 786.93 | 2 | 3 |
3 | 13 | 1741.60 | 19 | 14.32 | 2795 | 760 | 2.91 / 787.69 | 2 | 3 |
4 | 13 | 1024.00 | 19 | 14.49 | 1824 | 502 | 3.41 / 788.19 | 2 | 5 |
5 | 13 | 453.44 | 19 | 14.75 | 997 | 279 | 3.69 / 788.47 | 2 | 2 |
6 | 8 | 0.24 | 170 | 14.89 | 327 | 828 | 4.52 / 789.30 | 2 | 4 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 29 | 15.07 | 486 | 212 | 0.21 / 780.02 | 2 | 2 |
2 | 7 | 2003.20 | 43 | 14.33 | 3141 | 1935 | 2.15 / 781.96 | 2 | 2 |
3 | 13 | 1873.88 | 19 | 14.29 | 2981 | 809 | 2.96 / 782.77 | 2 | 3 |
4 | 13 | 1842.92 | 19 | 14.21 | 2936 | 793 | 3.75 / 783.56 | 2 | 3 |
5 | 13 | 478.28 | 19 | 14.74 | 1035 | 290 | 4.04 / 783.85 | 2 | 2 |
6 | 8 | 2.68 | 170 | 14.89 | 330 | 835 | 4.88 / 784.68 | 2 | 9 |
7 | 14 | 2.68 | 20 | 14.86 | 329 | 98 | 4.97 / 784.78 | 2 | 6 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 29 | 14.91 | 486 | 210 | 0.21 / 775.55 | 2 | 2 |
2 | 7 | 2003.16 | 43 | 14.33 | 3153 | 1943 | 2.15 / 777.49 | 2 | 2 |
3 | 13 | 1729.68 | 19 | 14.32 | 2785 | 758 | 2.91 / 778.25 | 2 | 3 |
4 | 13 | 1027.08 | 19 | 14.49 | 1829 | 504 | 3.41 / 778.75 | 2 | 3 |
5 | 13 | 326.84 | 19 | 14.81 | 818 | 230 | 3.64 / 778.98 | 2 | 3 |
6 | 8 | -0.20 | 170 | 14.89 | 327 | 828 | 4.47 / 779.81 | 2 | 5 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 29 | 15.06 | 483 | 211 | 0.21 / 771.13 | 2 | 2 |
2 | 7 | 2010.28 | 43 | 14.34 | 3139 | 1936 | 2.15 / 773.06 | 2 | 2 |
3 | 13 | 1606.68 | 19 | 14.34 | 2623 | 715 | 2.86 / 773.78 | 2 | 3 |
4 | 13 | 1049.68 | 19 | 14.47 | 1858 | 511 | 3.37 / 774.29 | 2 | 3 |
5 | 13 | 337.12 | 19 | 14.79 | 824 | 232 | 3.60 / 774.52 | 2 | 2 |
6 | 8 | -0.16 | 170 | 14.88 | 323 | 817 | 4.42 / 775.34 | 2 | 7 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 29 | 15.08 | 471 | 206 | 0.21 / 766.64 | 2 | 2 |
2 | 7 | 2002.24 | 43 | 14.34 | 3135 | 1933 | 2.14 / 768.57 | 2 | 2 |
3 | 13 | 1595.40 | 19 | 14.34 | 2601 | 709 | 2.85 / 769.28 | 2 | 3 |
4 | 13 | 1167.12 | 19 | 14.42 | 2004 | 549 | 3.40 / 769.83 | 2 | 4 |
5 | 13 | 431.72 | 19 | 14.74 | 963 | 270 | 3.67 / 770.10 | 2 | 2 |
6 | 8 | 0.40 | 170 | 14.88 | 324 | 820 | 4.49 / 770.92 | 2 | 6 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 29 | 14.91 | 477 | 206 | 0.21 / 762.23 | 2 | 2 |
2 | 7 | 2004.92 | 43 | 14.35 | 3136 | 1935 | 2.14 / 764.16 | 2 | 2 |
3 | 13 | 1609.00 | 19 | 14.35 | 2609 | 711 | 2.85 / 764.88 | 2 | 3 |
4 | 13 | 1045.08 | 19 | 14.48 | 1836 | 505 | 3.36 / 765.38 | 2 | 4 |
5 | 13 | 345.60 | 19 | 14.79 | 835 | 235 | 3.59 / 765.62 | 2 | 2 |
6 | 8 | 0.00 | 170 | 14.88 | 322 | 815 | 4.41 / 766.43 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 29 | 15.08 | 480 | 210 | 0.21 / 757.73 | 2 | 2 |
2 | 7 | 2007.20 | 43 | 14.34 | 3137 | 1934 | 2.14 / 759.67 | 2 | 2 |
3 | 13 | 1593.48 | 19 | 14.35 | 2605 | 710 | 2.85 / 760.38 | 2 | 5 |
4 | 13 | 1050.20 | 19 | 14.48 | 1844 | 507 | 3.36 / 760.88 | 2 | 5 |
5 | 13 | 339.72 | 19 | 14.79 | 826 | 232 | 3.59 / 761.12 | 2 | 2 |
6 | 13 | 17.32 | 19 | 14.93 | 351 | 100 | 3.69 / 761.22 | 2 | 2 |
7 | 8 | 0.12 | 170 | 14.87 | 319 | 806 | 4.50 / 762.02 | 2 | 12 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 29 | 14.86 | 472 | 203 | 0.20 / 753.30 | 2 | 2 |
2 | 7 | 2002.56 | 43 | 14.34 | 3131 | 1931 | 2.13 / 755.23 | 2 | 2 |
3 | 13 | 1590.32 | 19 | 14.35 | 2583 | 704 | 2.84 / 755.93 | 2 | 3 |
4 | 13 | 1037.24 | 19 | 14.49 | 1824 | 502 | 3.34 / 756.44 | 2 | 4 |
5 | 13 | 454.64 | 19 | 14.74 | 988 | 277 | 3.62 / 756.71 | 2 | 2 |
6 | 8 | -0.12 | 170 | 14.88 | 320 | 809 | 4.43 / 757.52 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 29 | 15.10 | 463 | 203 | 0.20 / 748.89 | 2 | 2 |
2 | 7 | 2002.92 | 44 | 14.33 | 3140 | 1980 | 2.18 / 750.87 | 2 | 2 |
3 | 13 | 1595.92 | 19 | 14.34 | 2596 | 707 | 2.89 / 751.57 | 2 | 4 |
4 | 13 | 1027.68 | 19 | 14.48 | 1816 | 500 | 3.39 / 752.07 | 2 | 3 |
5 | 13 | 312.48 | 19 | 14.80 | 786 | 221 | 3.61 / 752.29 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.88 | 317 | 802 | 4.41 / 753.10 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 29 | 14.88 | 466 | 201 | 0.20 / 744.47 | 2 | 2 |
2 | 7 | 2007.40 | 43 | 14.34 | 3142 | 1937 | 2.14 / 746.41 | 2 | 3 |
3 | 13 | 1732.72 | 19 | 14.33 | 2784 | 758 | 2.90 / 747.17 | 2 | 4 |
4 | 13 | 1021.84 | 19 | 14.50 | 1799 | 496 | 3.39 / 747.66 | 2 | 6 |
5 | 13 | 314.16 | 19 | 14.81 | 785 | 221 | 3.61 / 747.88 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.89 | 316 | 800 | 4.41 / 748.68 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 29 | 14.87 | 470 | 203 | 0.20 / 740.09 | 2 | 2 |
2 | 7 | 2009.72 | 43 | 14.35 | 3147 | 1942 | 2.14 / 742.03 | 2 | 2 |
3 | 13 | 1598.52 | 19 | 14.36 | 2598 | 709 | 2.85 / 742.74 | 2 | 3 |
4 | 13 | 1050.12 | 19 | 14.48 | 1845 | 508 | 3.36 / 743.25 | 2 | 3 |
5 | 13 | 339.60 | 19 | 14.80 | 824 | 232 | 3.59 / 743.48 | 2 | 2 |
6 | 8 | 0.04 | 170 | 14.90 | 312 | 790 | 4.38 / 744.27 | 2 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 29 | 14.86 | 460 | 198 | 0.20 / 735.49 | 2 | 2 |
2 | 7 | 2003.12 | 44 | 14.34 | 3135 | 1978 | 2.18 / 737.47 | 2 | 2 |
3 | 13 | 1588.32 | 19 | 14.35 | 2581 | 704 | 2.88 / 738.17 | 2 | 3 |
4 | 13 | 1033.36 | 19 | 14.49 | 1827 | 503 | 3.38 / 738.67 | 2 | 2 |
5 | 13 | 323.32 | 19 | 14.81 | 799 | 225 | 3.61 / 738.90 | 2 | 2 |
6 | 13 | 17.92 | 19 | 14.93 | 347 | 98 | 3.71 / 739.00 | 2 | 2 |
7 | 8 | -0.12 | 170 | 14.88 | 315 | 797 | 4.50 / 739.79 | 2 | 3 |
8 | 14 | -0.12 | 20 | 14.85 | 313 | 93 | 4.60 / 739.89 | 2 | 15 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 29 | 15.13 | 443 | 194 | 0.19 / 731.13 | 2 | 2 |
2 | 7 | 2008.28 | 43 | 14.34 | 3137 | 1934 | 2.13 / 733.06 | 2 | 2 |
3 | 13 | 1597.68 | 19 | 14.34 | 2599 | 708 | 2.84 / 733.77 | 2 | 3 |
4 | 13 | 1037.68 | 19 | 14.47 | 1831 | 503 | 3.34 / 734.27 | 2 | 3 |
5 | 13 | 327.16 | 19 | 14.80 | 806 | 227 | 3.57 / 734.50 | 2 | 2 |
6 | 8 | 0.36 | 170 | 14.88 | 314 | 794 | 4.36 / 735.29 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 29 | 14.88 | 459 | 198 | 0.20 / 726.70 | 2 | 2 |
2 | 7 | 2002.72 | 43 | 14.35 | 3149 | 1943 | 2.14 / 728.65 | 2 | 2 |
3 | 13 | 1592.44 | 19 | 14.35 | 2610 | 712 | 2.85 / 729.36 | 2 | 3 |
4 | 13 | 1043.96 | 19 | 14.49 | 1844 | 508 | 3.36 / 729.87 | 2 | 5 |
5 | 13 | 457.12 | 19 | 14.75 | 988 | 277 | 3.64 / 730.14 | 2 | 3 |
6 | 8 | 0.04 | 170 | 14.89 | 311 | 787 | 4.42 / 730.93 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 29 | 14.88 | 456 | 197 | 0.20 / 722.26 | 2 | 2 |
2 | 7 | 2007.60 | 43 | 14.35 | 3144 | 1940 | 2.14 / 724.20 | 2 | 2 |
3 | 13 | 1732.20 | 19 | 14.33 | 2782 | 757 | 2.89 / 724.96 | 2 | 2 |
4 | 13 | 1033.24 | 19 | 14.50 | 1822 | 502 | 3.40 / 725.46 | 2 | 4 |
5 | 13 | 450.16 | 19 | 14.76 | 977 | 274 | 3.67 / 725.73 | 2 | 2 |
6 | 8 | 0.24 | 170 | 14.90 | 306 | 775 | 4.45 / 726.51 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 29 | 15.13 | 436 | 191 | 0.19 / 717.81 | 2 | 2 |
2 | 7 | 2002.88 | 43 | 14.35 | 3130 | 1931 | 2.12 / 719.74 | 2 | 2 |
3 | 13 | 1599.52 | 19 | 14.36 | 2588 | 706 | 2.83 / 720.45 | 2 | 4 |
4 | 13 | 1165.36 | 19 | 14.43 | 2009 | 551 | 3.38 / 721.00 | 2 | 4 |
5 | 13 | 433.96 | 19 | 14.75 | 968 | 271 | 3.65 / 721.27 | 2 | 2 |
6 | 8 | 0.00 | 170 | 14.89 | 312 | 790 | 4.44 / 722.06 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 29 | 15.14 | 440 | 193 | 0.19 / 713.42 | 2 | 2 |
2 | 7 | 2002.04 | 43 | 14.35 | 3130 | 1931 | 2.12 / 715.35 | 2 | 3 |
3 | 13 | 1594.52 | 19 | 14.36 | 2593 | 707 | 2.83 / 716.05 | 2 | 4 |
4 | 13 | 1036.72 | 19 | 14.49 | 1822 | 502 | 3.33 / 716.56 | 2 | 4 |
5 | 13 | 460.08 | 19 | 14.74 | 998 | 279 | 3.61 / 716.84 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.89 | 310 | 785 | 4.40 / 717.62 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 29 | 14.88 | 448 | 193 | 0.19 / 709.12 | 2 | 2 |
2 | 7 | 2003.56 | 43 | 14.36 | 3124 | 1929 | 2.12 / 711.05 | 2 | 2 |
3 | 13 | 1600.12 | 19 | 14.36 | 2593 | 707 | 2.83 / 711.76 | 2 | 3 |
4 | 13 | 1046.00 | 19 | 14.49 | 1846 | 508 | 3.34 / 712.26 | 2 | 4 |
5 | 13 | 204.08 | 19 | 14.87 | 621 | 175 | 3.51 / 712.44 | 2 | 2 |
6 | 8 | -0.04 | 170 | 14.90 | 309 | 783 | 4.30 / 713.22 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 29 | 15.15 | 433 | 190 | 0.19 / 704.78 | 2 | 2 |
2 | 7 | 2006.60 | 43 | 14.35 | 3133 | 1933 | 2.12 / 706.71 | 2 | 2 |
3 | 13 | 1601.40 | 19 | 14.35 | 2594 | 707 | 2.83 / 707.42 | 2 | 5 |
4 | 13 | 1047.68 | 19 | 14.48 | 1834 | 505 | 3.34 / 707.92 | 2 | 5 |
5 | 13 | 338.48 | 19 | 14.80 | 814 | 229 | 3.56 / 708.15 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.89 | 307 | 777 | 4.34 / 708.93 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 29 | 14.88 | 458 | 198 | 0.20 / 700.41 | 2 | 2 |
2 | 7 | 2002.88 | 43 | 14.36 | 3131 | 1933 | 2.13 / 702.34 | 2 | 3 |
3 | 13 | 1474.56 | 19 | 14.39 | 2433 | 665 | 2.80 / 703.01 | 2 | 5 |
4 | 13 | 1068.12 | 19 | 14.47 | 1871 | 514 | 3.31 / 703.52 | 2 | 5 |
5 | 13 | 485.88 | 19 | 14.73 | 1028 | 288 | 3.60 / 703.81 | 2 | 3 |
6 | 8 | -0.20 | 170 | 14.90 | 307 | 778 | 4.38 / 704.58 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 29 | 15.13 | 441 | 193 | 0.19 / 695.97 | 2 | 2 |
2 | 7 | 2005.36 | 43 | 14.35 | 3132 | 1933 | 2.13 / 697.90 | 2 | 2 |
3 | 13 | 1723.60 | 19 | 14.34 | 2768 | 754 | 2.88 / 698.66 | 2 | 3 |
4 | 13 | 1014.56 | 19 | 14.50 | 1798 | 495 | 3.38 / 699.15 | 2 | 5 |
5 | 13 | 445.00 | 19 | 14.75 | 974 | 273 | 3.65 / 699.42 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.90 | 310 | 785 | 4.43 / 700.21 | 2 | 3 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 29 | 14.88 | 456 | 197 | 0.20 / 691.53 | 2 | 2 |
2 | 7 | 2006.68 | 43 | 14.36 | 3132 | 1934 | 2.13 / 693.47 | 2 | 3 |
3 | 13 | 1725.52 | 19 | 14.34 | 2762 | 753 | 2.88 / 694.22 | 2 | 4 |
4 | 13 | 1026.68 | 19 | 14.51 | 1802 | 497 | 3.38 / 694.72 | 2 | 3 |
5 | 13 | 456.00 | 19 | 14.76 | 981 | 275 | 3.66 / 694.99 | 2 | 2 |
6 | 8 | 0.36 | 170 | 14.91 | 309 | 783 | 4.44 / 695.78 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 29 | 14.87 | 458 | 198 | 0.20 / 687.17 | 2 | 2 |
2 | 7 | 2007.56 | 43 | 14.36 | 3127 | 1931 | 2.13 / 689.10 | 2 | 3 |
3 | 13 | 1606.08 | 19 | 14.37 | 2599 | 710 | 2.84 / 689.81 | 2 | 5 |
4 | 13 | 1051.08 | 19 | 14.49 | 1841 | 507 | 3.34 / 690.32 | 2 | 5 |
5 | 13 | 336.32 | 19 | 14.81 | 815 | 229 | 3.57 / 690.55 | 2 | 2 |
6 | 8 | -0.12 | 170 | 14.90 | 311 | 788 | 4.36 / 691.34 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 29 | 15.13 | 457 | 201 | 0.20 / 682.74 | 2 | 2 |
2 | 7 | 2002.92 | 44 | 14.35 | 3132 | 1978 | 2.18 / 684.72 | 2 | 2 |
3 | 13 | 1584.52 | 19 | 14.37 | 2585 | 706 | 2.88 / 685.42 | 2 | 4 |
4 | 13 | 1019.20 | 19 | 14.50 | 1803 | 497 | 3.38 / 685.92 | 2 | 5 |
5 | 13 | 421.80 | 19 | 14.76 | 934 | 262 | 3.64 / 686.18 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.89 | 314 | 795 | 4.44 / 686.97 | 2 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 29 | 14.89 | 469 | 203 | 0.20 / 678.22 | 2 | 2 |
2 | 7 | 2002.92 | 43 | 14.36 | 3122 | 1928 | 2.13 / 680.15 | 2 | 3 |
3 | 13 | 1594.44 | 19 | 14.37 | 2588 | 707 | 2.84 / 680.85 | 2 | 4 |
4 | 13 | 1036.24 | 19 | 14.50 | 1818 | 501 | 3.34 / 681.36 | 2 | 4 |
5 | 13 | 457.48 | 19 | 14.75 | 1000 | 280 | 3.62 / 681.64 | 2 | 2 |
6 | 13 | 17.88 | 19 | 14.94 | 347 | 98 | 3.72 / 681.73 | 2 | 2 |
7 | 8 | 0.24 | 170 | 14.90 | 317 | 803 | 4.52 / 682.54 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 29 | 14.87 | 458 | 198 | 0.20 / 673.69 | 2 | 2 |
2 | 3 | 1021.92 | 1 | 15.12 | 1818 | 27 | 0.22 / 673.72 | 2 | 2 |
3 | 7 | 2003.56 | 43 | 14.36 | 3125 | 1930 | 2.15 / 675.65 | 2 | 2 |
4 | 13 | 1604.08 | 19 | 14.37 | 2602 | 710 | 2.87 / 676.36 | 2 | 2 |
5 | 13 | 1044.76 | 19 | 14.50 | 1825 | 503 | 3.37 / 676.86 | 2 | 3 |
6 | 13 | 463.84 | 19 | 14.76 | 991 | 278 | 3.65 / 677.14 | 2 | 2 |
7 | 8 | 0.08 | 170 | 14.91 | 311 | 788 | 4.43 / 677.92 | 2 | 10 |
8 | 14 | 0.08 | 20 | 14.88 | 314 | 93 | 4.53 / 678.02 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 28 | 15.15 | 435 | 185 | 0.18 / 669.23 | 2 | 2 |
2 | 7 | 2007.00 | 44 | 14.34 | 3146 | 1985 | 2.17 / 671.22 | 2 | 2 |
3 | 13 | 1596.40 | 19 | 14.36 | 2606 | 711 | 2.88 / 671.93 | 2 | 2 |
4 | 13 | 1028.20 | 19 | 14.49 | 1811 | 499 | 3.38 / 672.43 | 2 | 3 |
5 | 13 | 453.12 | 19 | 14.75 | 981 | 275 | 3.65 / 672.70 | 2 | 2 |
6 | 8 | -0.16 | 170 | 14.89 | 312 | 790 | 4.44 / 673.49 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 28 | 15.15 | 435 | 185 | 0.18 / 664.69 | 2 | 2 |
2 | 7 | 2007.44 | 43 | 14.36 | 3139 | 1938 | 2.12 / 666.63 | 2 | 2 |
3 | 13 | 1593.44 | 19 | 14.37 | 2585 | 706 | 2.83 / 667.33 | 2 | 3 |
4 | 13 | 1165.48 | 19 | 14.44 | 2000 | 549 | 3.38 / 667.88 | 2 | 5 |
5 | 13 | 428.68 | 19 | 14.77 | 950 | 267 | 3.64 / 668.15 | 2 | 2 |
6 | 13 | 81.36 | 19 | 14.92 | 433 | 123 | 3.77 / 668.27 | 2 | 2 |
7 | 8 | 0.36 | 170 | 14.90 | 307 | 778 | 4.54 / 669.05 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 29 | 15.14 | 439 | 193 | 0.19 / 660.34 | 2 | 2 |
2 | 7 | 2004.04 | 44 | 14.35 | 3118 | 1969 | 2.16 / 662.31 | 2 | 3 |
3 | 13 | 1590.48 | 19 | 14.36 | 2581 | 704 | 2.87 / 663.01 | 2 | 4 |
4 | 13 | 1030.08 | 19 | 14.50 | 1815 | 500 | 3.37 / 663.51 | 2 | 6 |
5 | 13 | 306.28 | 19 | 14.83 | 769 | 217 | 3.58 / 663.73 | 2 | 3 |
6 | 8 | 0.00 | 170 | 14.91 | 306 | 776 | 4.36 / 664.50 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 29 | 15.13 | 446 | 196 | 0.20 / 655.95 | 2 | 2 |
2 | 7 | 2004.76 | 44 | 14.36 | 3123 | 1973 | 2.17 / 657.92 | 2 | 2 |
3 | 13 | 1593.84 | 19 | 14.37 | 2590 | 707 | 2.88 / 658.63 | 2 | 5 |
4 | 13 | 1023.76 | 19 | 14.50 | 1807 | 498 | 3.37 / 659.13 | 2 | 3 |
5 | 13 | 310.16 | 19 | 14.82 | 781 | 220 | 3.59 / 659.35 | 2 | 2 |
6 | 8 | -0.08 | 170 | 14.90 | 315 | 798 | 4.39 / 660.14 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 29 | 15.10 | 476 | 208 | 0.21 / 651.59 | 2 | 2 |
2 | 7 | 2006.36 | 43 | 14.36 | 3127 | 1931 | 2.14 / 653.52 | 2 | 2 |
3 | 13 | 1583.52 | 19 | 14.37 | 2579 | 704 | 2.84 / 654.23 | 2 | 4 |
4 | 13 | 1031.12 | 19 | 14.50 | 1821 | 502 | 3.35 / 654.73 | 2 | 5 |
5 | 13 | 317.56 | 19 | 14.82 | 797 | 224 | 3.57 / 654.95 | 2 | 3 |
6 | 8 | 0.12 | 170 | 14.90 | 316 | 800 | 4.37 / 655.75 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 29 | 14.89 | 476 | 206 | 0.21 / 647.13 | 2 | 2 |
2 | 7 | 2004.40 | 43 | 14.37 | 3129 | 1933 | 2.14 / 649.07 | 2 | 2 |
3 | 13 | 1594.68 | 19 | 14.38 | 2610 | 713 | 2.85 / 649.78 | 2 | 3 |
4 | 13 | 1162.08 | 19 | 14.45 | 2002 | 550 | 3.40 / 650.33 | 2 | 4 |
5 | 13 | 306.72 | 19 | 14.83 | 790 | 223 | 3.62 / 650.55 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.90 | 328 | 831 | 4.46 / 651.38 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 29 | 15.13 | 442 | 194 | 0.19 / 642.64 | 2 | 2 |
2 | 7 | 2004.00 | 43 | 14.37 | 3122 | 1929 | 2.12 / 644.57 | 2 | 2 |
3 | 13 | 1736.32 | 19 | 14.35 | 2775 | 757 | 2.88 / 645.33 | 2 | 3 |
4 | 13 | 1152.72 | 19 | 14.46 | 1978 | 543 | 3.42 / 645.87 | 2 | 6 |
5 | 13 | 424.64 | 19 | 14.78 | 942 | 265 | 3.69 / 646.14 | 2 | 2 |
6 | 8 | 0.32 | 170 | 14.91 | 312 | 791 | 4.48 / 646.93 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 29 | 15.15 | 447 | 196 | 0.20 / 638.21 | 2 | 2 |
2 | 7 | 2006.32 | 43 | 14.37 | 3136 | 1938 | 2.13 / 640.15 | 2 | 2 |
3 | 13 | 1734.52 | 19 | 14.35 | 2778 | 757 | 2.89 / 640.90 | 2 | 2 |
4 | 13 | 1023.60 | 19 | 14.52 | 1788 | 493 | 3.38 / 641.40 | 2 | 4 |
5 | 13 | 455.32 | 19 | 14.77 | 981 | 275 | 3.66 / 641.67 | 2 | 2 |
6 | 8 | 0.36 | 170 | 14.91 | 307 | 778 | 4.44 / 642.45 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 29 | 14.87 | 455 | 196 | 0.20 / 633.76 | 2 | 2 |
2 | 7 | 2004.96 | 43 | 14.37 | 3137 | 1938 | 2.13 / 635.70 | 2 | 2 |
3 | 13 | 1723.56 | 19 | 14.36 | 2765 | 754 | 2.89 / 636.45 | 2 | 3 |
4 | 13 | 1132.60 | 19 | 14.48 | 1947 | 536 | 3.42 / 636.99 | 2 | 6 |
5 | 13 | 408.32 | 19 | 14.80 | 915 | 257 | 3.68 / 637.24 | 2 | 2 |
6 | 8 | 0.28 | 170 | 14.92 | 302 | 766 | 4.45 / 638.01 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 29 | 14.88 | 445 | 192 | 0.19 / 629.48 | 2 | 2 |
2 | 7 | 2008.20 | 43 | 14.37 | 3137 | 1938 | 2.13 / 631.41 | 2 | 3 |
3 | 13 | 1479.60 | 19 | 14.41 | 2436 | 667 | 2.80 / 632.08 | 2 | 3 |
4 | 13 | 1066.60 | 19 | 14.49 | 1865 | 513 | 3.31 / 632.59 | 2 | 2 |
5 | 13 | 215.72 | 19 | 14.87 | 639 | 181 | 3.49 / 632.77 | 2 | 2 |
6 | 8 | -0.16 | 170 | 14.91 | 311 | 788 | 4.28 / 633.56 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 29 | 15.13 | 439 | 193 | 0.19 / 625.17 | 2 | 2 |
2 | 7 | 2005.52 | 43 | 14.36 | 3132 | 1934 | 2.13 / 627.11 | 2 | 2 |
3 | 13 | 1597.72 | 19 | 14.38 | 2587 | 707 | 2.83 / 627.81 | 2 | 4 |
4 | 13 | 916.12 | 19 | 14.57 | 1639 | 454 | 3.29 / 628.27 | 2 | 3 |
5 | 13 | 358.72 | 19 | 14.81 | 844 | 237 | 3.52 / 628.51 | 2 | 2 |
6 | 8 | 0.36 | 170 | 14.91 | 307 | 778 | 4.30 / 629.28 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 29 | 15.13 | 462 | 203 | 0.20 / 620.74 | 2 | 2 |
2 | 7 | 2004.56 | 43 | 14.38 | 3136 | 1939 | 2.14 / 622.68 | 2 | 2 |
3 | 13 | 1598.88 | 19 | 14.38 | 2589 | 707 | 2.85 / 623.38 | 2 | 5 |
4 | 13 | 1166.12 | 19 | 14.46 | 2008 | 552 | 3.40 / 623.94 | 2 | 5 |
5 | 13 | 441.76 | 19 | 14.77 | 960 | 269 | 3.67 / 624.20 | 2 | 2 |
6 | 8 | 0.52 | 170 | 14.91 | 306 | 776 | 4.45 / 624.98 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 29 | 14.88 | 453 | 195 | 0.20 / 616.39 | 2 | 2 |
2 | 7 | 2006.68 | 44 | 14.38 | 3131 | 1981 | 2.18 / 618.37 | 2 | 2 |
3 | 13 | 1588.48 | 19 | 14.39 | 2584 | 706 | 2.88 / 619.08 | 2 | 3 |
4 | 13 | 894.88 | 19 | 14.59 | 1617 | 448 | 3.33 / 619.53 | 2 | 4 |
5 | 13 | 330.72 | 19 | 14.83 | 807 | 227 | 3.56 / 619.75 | 2 | 3 |
6 | 8 | -0.04 | 170 | 14.91 | 308 | 781 | 4.34 / 620.53 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 29 | 15.15 | 447 | 196 | 0.20 / 611.99 | 2 | 2 |
2 | 7 | 2007.04 | 44 | 14.37 | 3137 | 1983 | 2.18 / 613.98 | 2 | 2 |
3 | 13 | 1589.64 | 19 | 14.38 | 2583 | 706 | 2.89 / 614.68 | 2 | 3 |
4 | 13 | 1028.52 | 19 | 14.51 | 1816 | 501 | 3.39 / 615.18 | 2 | 5 |
5 | 13 | 326.36 | 19 | 14.82 | 801 | 226 | 3.61 / 615.41 | 2 | 2 |
6 | 8 | 0.24 | 170 | 14.91 | 310 | 786 | 4.40 / 616.20 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 29 | 15.15 | 441 | 194 | 0.19 / 607.50 | 2 | 2 |
2 | 7 | 2003.88 | 42 | 14.39 | 3125 | 1889 | 2.08 / 609.39 | 2 | 3 |
3 | 13 | 1732.00 | 21 | 14.35 | 2777 | 837 | 2.92 / 610.23 | 2 | 3 |
4 | 13 | 1010.24 | 21 | 14.53 | 1785 | 545 | 3.46 / 610.77 | 2 | 4 |
5 | 13 | 295.60 | 21 | 14.85 | 751 | 234 | 3.70 / 611.01 | 2 | 2 |
6 | 8 | 0.28 | 170 | 14.92 | 312 | 791 | 4.49 / 611.80 | 2 | 3 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 28 | 14.90 | 451 | 188 | 0.19 / 602.97 | 2 | 2 |
2 | 3 | 1025.24 | 1 | 15.13 | 1812 | 27 | 0.22 / 603.00 | 2 | 2 |
3 | 7 | 2007.48 | 42 | 14.39 | 3145 | 1901 | 2.12 / 604.90 | 2 | 2 |
4 | 13 | 1604.52 | 21 | 14.38 | 2606 | 787 | 2.90 / 605.69 | 2 | 3 |
5 | 13 | 1167.56 | 21 | 14.46 | 2005 | 609 | 3.51 / 606.30 | 2 | 2 |
6 | 13 | 267.88 | 21 | 14.85 | 717 | 224 | 3.74 / 606.52 | 2 | 2 |
7 | 8 | -0.24 | 170 | 14.91 | 310 | 786 | 4.52 / 607.31 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 28 | 15.17 | 452 | 192 | 0.19 / 598.58 | 2 | 2 |
2 | 7 | 2008.92 | 41 | 14.37 | 3147 | 1854 | 2.05 / 600.43 | 2 | 2 |
3 | 13 | 1736.44 | 21 | 14.35 | 2789 | 840 | 2.89 / 601.27 | 2 | 2 |
4 | 13 | 1013.80 | 21 | 14.53 | 1784 | 544 | 3.43 / 601.81 | 2 | 3 |
5 | 13 | 160.32 | 21 | 14.91 | 568 | 178 | 3.61 / 601.99 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.93 | 313 | 794 | 4.40 / 602.79 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 29 | 15.16 | 450 | 198 | 0.20 / 594.15 | 2 | 2 |
2 | 7 | 2004.20 | 42 | 14.38 | 3133 | 1892 | 2.09 / 596.04 | 2 | 2 |
3 | 13 | 1721.76 | 21 | 14.35 | 2758 | 831 | 2.92 / 596.87 | 2 | 4 |
4 | 13 | 1009.40 | 21 | 14.53 | 1794 | 547 | 3.47 / 597.42 | 2 | 3 |
5 | 13 | 162.04 | 21 | 14.91 | 569 | 178 | 3.65 / 597.59 | 2 | 2 |
6 | 8 | -0.04 | 170 | 14.93 | 311 | 789 | 4.44 / 598.38 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 29 | 14.90 | 458 | 198 | 0.20 / 589.70 | 2 | 2 |
2 | 7 | 2003.16 | 41 | 14.39 | 3134 | 1849 | 2.05 / 591.55 | 2 | 2 |
3 | 13 | 1736.20 | 21 | 14.35 | 2771 | 835 | 2.88 / 592.38 | 2 | 4 |
4 | 13 | 1013.80 | 21 | 14.54 | 1794 | 548 | 3.43 / 592.93 | 2 | 5 |
5 | 13 | 293.52 | 21 | 14.85 | 753 | 235 | 3.66 / 593.17 | 2 | 2 |
6 | 8 | 0.16 | 170 | 14.93 | 308 | 782 | 4.45 / 593.95 | 2 | 3 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 28 | 14.92 | 447 | 187 | 0.19 / 585.32 | 2 | 2 |
2 | 3 | 1019.52 | 1 | 15.14 | 1813 | 27 | 0.21 / 585.35 | 2 | 2 |
3 | 7 | 2004.12 | 41 | 14.38 | 3132 | 1847 | 2.06 / 587.19 | 2 | 3 |
4 | 13 | 1598.64 | 21 | 14.38 | 2602 | 786 | 2.85 / 587.98 | 2 | 3 |
5 | 13 | 1035.00 | 21 | 14.51 | 1830 | 558 | 3.40 / 588.54 | 2 | 5 |
6 | 13 | 170.92 | 21 | 14.90 | 581 | 182 | 3.59 / 588.72 | 2 | 2 |
7 | 8 | 0.12 | 170 | 14.92 | 308 | 781 | 4.37 / 589.50 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 28 | 15.19 | 427 | 182 | 0.18 / 580.98 | 2 | 2 |
2 | 7 | 2008.04 | 41 | 14.39 | 3136 | 1850 | 2.03 / 582.83 | 2 | 3 |
3 | 13 | 1616.96 | 21 | 14.38 | 2616 | 790 | 2.82 / 583.62 | 2 | 3 |
4 | 13 | 1069.88 | 21 | 14.50 | 1858 | 566 | 3.39 / 584.18 | 2 | 6 |
5 | 13 | 208.76 | 21 | 14.90 | 615 | 192 | 3.58 / 584.37 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.94 | 299 | 759 | 4.34 / 585.13 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 29 | 15.20 | 430 | 190 | 0.19 / 576.65 | 2 | 2 |
2 | 7 | 2006.32 | 41 | 14.38 | 3122 | 1841 | 2.03 / 578.49 | 2 | 2 |
3 | 13 | 1726.08 | 21 | 14.36 | 2758 | 832 | 2.86 / 579.32 | 2 | 4 |
4 | 13 | 1010.68 | 21 | 14.53 | 1780 | 543 | 3.41 / 579.86 | 2 | 3 |
5 | 13 | 161.68 | 21 | 14.92 | 554 | 174 | 3.58 / 580.04 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.94 | 299 | 759 | 4.34 / 580.79 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 29 | 14.92 | 450 | 195 | 0.19 / 572.19 | 2 | 2 |
2 | 7 | 2002.96 | 41 | 14.39 | 3127 | 1845 | 2.04 / 574.03 | 2 | 2 |
3 | 13 | 1734.44 | 21 | 14.37 | 2769 | 836 | 2.88 / 574.87 | 2 | 2 |
4 | 13 | 1148.44 | 21 | 14.48 | 1980 | 602 | 3.48 / 575.47 | 2 | 5 |
5 | 13 | 275.72 | 21 | 14.87 | 717 | 224 | 3.70 / 575.69 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.94 | 300 | 762 | 4.46 / 576.46 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 28 | 14.93 | 456 | 191 | 0.19 / 567.74 | 2 | 2 |
2 | 3 | 1026.76 | 1 | 15.12 | 1849 | 28 | 0.22 / 567.77 | 2 | 2 |
3 | 7 | 2004.44 | 41 | 14.39 | 3129 | 1846 | 2.06 / 569.61 | 2 | 3 |
4 | 13 | 1727.60 | 21 | 14.36 | 2758 | 832 | 2.90 / 570.44 | 2 | 3 |
5 | 13 | 1012.96 | 21 | 14.54 | 1792 | 547 | 3.44 / 570.99 | 2 | 3 |
6 | 13 | 283.72 | 21 | 14.87 | 741 | 231 | 3.67 / 571.22 | 2 | 2 |
7 | 8 | 0.04 | 170 | 14.94 | 304 | 772 | 4.45 / 571.99 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 28 | 15.20 | 424 | 180 | 0.18 / 563.38 | 2 | 2 |
2 | 7 | 2004.40 | 41 | 14.37 | 3138 | 1849 | 2.03 / 565.23 | 2 | 3 |
3 | 13 | 1594.20 | 21 | 14.38 | 2586 | 781 | 2.81 / 566.01 | 2 | 5 |
4 | 13 | 1023.64 | 21 | 14.52 | 1801 | 549 | 3.36 / 566.56 | 2 | 5 |
5 | 13 | 286.88 | 21 | 14.85 | 735 | 229 | 3.59 / 566.79 | 2 | 2 |
6 | 8 | 0.24 | 170 | 14.93 | 299 | 759 | 4.35 / 567.55 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 28 | 15.20 | 431 | 183 | 0.18 / 559.05 | 2 | 2 |
2 | 7 | 2008.24 | 41 | 14.37 | 3137 | 1848 | 2.03 / 560.90 | 2 | 2 |
3 | 13 | 1602.32 | 21 | 14.38 | 2601 | 785 | 2.82 / 561.68 | 2 | 2 |
4 | 13 | 1037.52 | 21 | 14.52 | 1830 | 558 | 3.38 / 562.24 | 2 | 5 |
5 | 13 | 176.16 | 21 | 14.91 | 588 | 184 | 3.56 / 562.43 | 2 | 2 |
6 | 8 | 0.24 | 170 | 14.94 | 304 | 772 | 4.33 / 563.20 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 28 | 15.20 | 423 | 180 | 0.18 / 554.72 | 2 | 2 |
2 | 7 | 2002.76 | 41 | 14.38 | 3128 | 1844 | 2.02 / 556.56 | 2 | 2 |
3 | 13 | 1727.20 | 21 | 14.36 | 2761 | 833 | 2.86 / 557.39 | 2 | 3 |
4 | 13 | 1008.88 | 21 | 14.54 | 1777 | 543 | 3.40 / 557.93 | 2 | 4 |
5 | 13 | 156.68 | 21 | 14.93 | 545 | 171 | 3.57 / 558.11 | 2 | 2 |
6 | 8 | -0.16 | 170 | 14.94 | 300 | 762 | 4.33 / 558.87 | 2 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 29 | 15.20 | 422 | 186 | 0.19 / 550.35 | 2 | 2 |
2 | 7 | 2003.00 | 42 | 14.38 | 3125 | 1887 | 2.07 / 552.24 | 2 | 2 |
3 | 13 | 1609.36 | 21 | 14.38 | 2607 | 787 | 2.86 / 553.03 | 2 | 4 |
4 | 13 | 1042.72 | 21 | 14.52 | 1828 | 557 | 3.42 / 553.59 | 2 | 5 |
5 | 13 | 180.24 | 21 | 14.91 | 582 | 182 | 3.60 / 553.77 | 2 | 2 |
6 | 8 | -0.08 | 170 | 14.94 | 302 | 767 | 4.37 / 554.54 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 29 | 14.93 | 447 | 194 | 0.19 / 545.90 | 2 | 2 |
2 | 7 | 2002.40 | 41 | 14.39 | 3126 | 1844 | 2.04 / 547.74 | 2 | 3 |
3 | 13 | 1601.36 | 21 | 14.39 | 2584 | 781 | 2.82 / 548.52 | 2 | 5 |
4 | 13 | 1021.16 | 21 | 14.53 | 1803 | 550 | 3.37 / 549.07 | 2 | 4 |
5 | 13 | 278.32 | 21 | 14.86 | 728 | 227 | 3.60 / 549.30 | 2 | 2 |
6 | 13 | 24.16 | 21 | 14.97 | 341 | 107 | 3.70 / 549.41 | 2 | 2 |
7 | 8 | -0.08 | 170 | 14.93 | 300 | 761 | 4.46 / 550.17 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 29 | 14.93 | 445 | 193 | 0.19 / 541.53 | 2 | 2 |
2 | 7 | 2006.68 | 41 | 14.39 | 3134 | 1849 | 2.04 / 543.38 | 2 | 2 |
3 | 13 | 1729.36 | 21 | 14.37 | 2773 | 837 | 2.88 / 544.22 | 2 | 3 |
4 | 13 | 998.84 | 21 | 14.55 | 1770 | 541 | 3.42 / 544.76 | 2 | 3 |
5 | 13 | 143.80 | 21 | 14.94 | 525 | 165 | 3.58 / 544.92 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.95 | 307 | 780 | 4.36 / 545.70 | 2 | 3 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 29 | 14.93 | 446 | 193 | 0.19 / 537.21 | 2 | 2 |
2 | 7 | 2005.24 | 41 | 14.39 | 3125 | 1844 | 2.04 / 539.06 | 2 | 2 |
3 | 13 | 1590.80 | 21 | 14.40 | 2588 | 783 | 2.82 / 539.84 | 2 | 4 |
4 | 13 | 1016.24 | 21 | 14.54 | 1790 | 547 | 3.37 / 540.39 | 2 | 6 |
5 | 13 | 159.16 | 21 | 14.93 | 552 | 173 | 3.54 / 540.56 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.95 | 307 | 780 | 4.32 / 541.34 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 29 | 15.00 | 443 | 193 | 0.19 / 532.83 | 2 | 2 |
2 | 7 | 2004.52 | 42 | 14.39 | 3129 | 1891 | 2.08 / 534.72 | 2 | 3 |
3 | 13 | 1598.76 | 21 | 14.40 | 2588 | 783 | 2.87 / 535.51 | 2 | 4 |
4 | 13 | 1034.96 | 21 | 14.53 | 1823 | 556 | 3.42 / 536.06 | 2 | 4 |
5 | 13 | 173.80 | 21 | 14.92 | 579 | 181 | 3.60 / 536.24 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.95 | 305 | 775 | 4.38 / 537.02 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 29 | 14.93 | 447 | 194 | 0.19 / 528.50 | 2 | 2 |
2 | 7 | 2004.24 | 41 | 14.39 | 3135 | 1850 | 2.04 / 530.35 | 2 | 3 |
3 | 13 | 1600.32 | 21 | 14.40 | 2600 | 786 | 2.83 / 531.13 | 2 | 5 |
4 | 13 | 1022.68 | 21 | 14.53 | 1802 | 550 | 3.38 / 531.68 | 2 | 3 |
5 | 13 | 165.72 | 21 | 14.93 | 562 | 176 | 3.56 / 531.86 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.94 | 308 | 782 | 4.34 / 532.64 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 28 | 14.94 | 464 | 194 | 0.19 / 524.15 | 2 | 2 |
2 | 7 | 2008.56 | 41 | 14.39 | 3123 | 1843 | 2.04 / 525.99 | 2 | 2 |
3 | 13 | 1610.52 | 21 | 14.40 | 2619 | 792 | 2.83 / 526.79 | 2 | 3 |
4 | 13 | 1033.72 | 21 | 14.53 | 1826 | 557 | 3.39 / 527.34 | 2 | 4 |
5 | 13 | 163.44 | 21 | 14.93 | 564 | 177 | 3.56 / 527.52 | 2 | 2 |
6 | 8 | -0.20 | 170 | 14.94 | 308 | 782 | 4.34 / 528.30 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 28 | 14.93 | 456 | 191 | 0.19 / 519.80 | 2 | 2 |
2 | 7 | 2002.00 | 41 | 14.40 | 3128 | 1847 | 2.04 / 521.64 | 2 | 2 |
3 | 13 | 1724.48 | 21 | 14.37 | 2762 | 833 | 2.87 / 522.48 | 2 | 5 |
4 | 13 | 995.68 | 21 | 14.56 | 1768 | 541 | 3.41 / 523.02 | 2 | 5 |
5 | 13 | 131.16 | 21 | 14.96 | 511 | 161 | 3.57 / 523.18 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.96 | 307 | 781 | 4.35 / 523.96 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 28 | 15.17 | 451 | 192 | 0.19 / 515.47 | 2 | 2 |
2 | 7 | 2004.24 | 42 | 14.39 | 3131 | 1892 | 2.08 / 517.37 | 2 | 2 |
3 | 13 | 1597.28 | 21 | 14.40 | 2590 | 783 | 2.87 / 518.15 | 2 | 5 |
4 | 13 | 1028.60 | 21 | 14.53 | 1808 | 552 | 3.42 / 518.70 | 2 | 5 |
5 | 13 | 77.72 | 21 | 14.97 | 425 | 134 | 3.55 / 518.84 | 2 | 2 |
6 | 8 | 0.24 | 170 | 14.95 | 303 | 770 | 4.32 / 519.61 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 28 | 14.92 | 477 | 199 | 0.20 / 511.14 | 2 | 2 |
2 | 7 | 2003.88 | 41 | 14.40 | 3123 | 1844 | 2.04 / 512.98 | 2 | 2 |
3 | 13 | 1586.32 | 21 | 14.41 | 2583 | 782 | 2.82 / 513.76 | 2 | 3 |
4 | 13 | 1022.76 | 21 | 14.54 | 1809 | 552 | 3.38 / 514.31 | 2 | 4 |
5 | 13 | 140.52 | 21 | 14.94 | 537 | 168 | 3.55 / 514.48 | 2 | 2 |
6 | 8 | -0.20 | 170 | 14.95 | 315 | 801 | 4.35 / 515.28 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 28 | 14.91 | 459 | 192 | 0.19 / 506.72 | 2 | 2 |
2 | 7 | 2003.20 | 42 | 14.41 | 3135 | 1897 | 2.09 / 508.61 | 2 | 2 |
3 | 13 | 1595.40 | 21 | 14.41 | 2600 | 787 | 2.88 / 509.40 | 2 | 3 |
4 | 13 | 1027.56 | 21 | 14.54 | 1816 | 554 | 3.43 / 509.96 | 2 | 5 |
5 | 13 | 162.08 | 21 | 14.94 | 568 | 178 | 3.61 / 510.13 | 2 | 2 |
6 | 8 | 0.28 | 170 | 14.95 | 316 | 803 | 4.41 / 510.94 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 28 | 14.92 | 458 | 191 | 0.19 / 502.21 | 2 | 2 |
2 | 7 | 2004.28 | 42 | 14.40 | 3123 | 1889 | 2.08 / 504.10 | 2 | 2 |
3 | 13 | 1724.48 | 21 | 14.39 | 2770 | 837 | 2.92 / 504.94 | 2 | 4 |
4 | 13 | 1008.16 | 21 | 14.55 | 1795 | 548 | 3.47 / 505.49 | 2 | 4 |
5 | 13 | 283.60 | 21 | 14.88 | 747 | 233 | 3.70 / 505.72 | 2 | 2 |
6 | 8 | -0.12 | 170 | 14.94 | 316 | 803 | 4.50 / 506.53 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 28 | 15.15 | 472 | 200 | 0.20 / 497.86 | 2 | 2 |
2 | 7 | 2002.44 | 41 | 14.40 | 3126 | 1846 | 2.05 / 499.71 | 2 | 3 |
3 | 13 | 1599.48 | 21 | 14.41 | 2595 | 785 | 2.83 / 500.49 | 2 | 4 |
4 | 13 | 1030.40 | 21 | 14.54 | 1813 | 554 | 3.38 / 501.04 | 2 | 5 |
5 | 13 | 173.44 | 21 | 14.93 | 577 | 181 | 3.57 / 501.23 | 2 | 2 |
6 | 8 | 0.04 | 170 | 14.95 | 314 | 798 | 4.36 / 502.02 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 28 | 15.15 | 470 | 199 | 0.20 / 493.48 | 2 | 2 |
2 | 7 | 2005.44 | 41 | 14.40 | 3126 | 1846 | 2.04 / 495.32 | 2 | 2 |
3 | 13 | 1605.28 | 21 | 14.40 | 2605 | 788 | 2.83 / 496.11 | 2 | 3 |
4 | 13 | 1037.16 | 21 | 14.54 | 1830 | 559 | 3.39 / 496.67 | 2 | 3 |
5 | 13 | 164.44 | 21 | 14.93 | 565 | 177 | 3.57 / 496.85 | 2 | 2 |
6 | 8 | 0.16 | 170 | 14.95 | 320 | 813 | 4.38 / 497.66 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 28 | 14.91 | 486 | 203 | 0.20 / 489.08 | 2 | 2 |
2 | 7 | 2007.28 | 41 | 14.41 | 3120 | 1843 | 2.05 / 490.93 | 2 | 2 |
3 | 13 | 1613.60 | 21 | 14.41 | 2629 | 796 | 2.84 / 491.72 | 2 | 4 |
4 | 13 | 1047.72 | 21 | 14.54 | 1850 | 565 | 3.41 / 492.29 | 2 | 6 |
5 | 13 | 185.72 | 21 | 14.93 | 595 | 187 | 3.59 / 492.47 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.95 | 316 | 803 | 4.40 / 493.28 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 28 | 15.15 | 456 | 193 | 0.19 / 484.60 | 2 | 2 |
2 | 7 | 2006.28 | 42 | 14.40 | 3140 | 1899 | 2.09 / 486.50 | 2 | 3 |
3 | 13 | 1599.80 | 21 | 14.41 | 2589 | 783 | 2.88 / 487.29 | 2 | 3 |
4 | 13 | 1020.04 | 21 | 14.55 | 1803 | 551 | 3.43 / 487.84 | 2 | 4 |
5 | 13 | 287.80 | 21 | 14.88 | 745 | 233 | 3.66 / 488.07 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.94 | 320 | 813 | 4.47 / 488.88 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 28 | 15.08 | 467 | 197 | 0.20 / 480.20 | 2 | 2 |
2 | 7 | 2003.32 | 41 | 14.41 | 3124 | 1846 | 2.04 / 482.05 | 2 | 2 |
3 | 13 | 1728.96 | 21 | 14.39 | 2766 | 836 | 2.88 / 482.89 | 2 | 3 |
4 | 13 | 1005.64 | 21 | 14.56 | 1790 | 547 | 3.43 / 483.43 | 2 | 4 |
5 | 13 | 161.08 | 21 | 14.95 | 559 | 175 | 3.60 / 483.61 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.96 | 315 | 801 | 4.40 / 484.41 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 28 | 14.92 | 485 | 203 | 0.20 / 475.75 | 2 | 2 |
2 | 7 | 2003.92 | 41 | 14.41 | 3132 | 1850 | 2.05 / 477.60 | 2 | 3 |
3 | 13 | 1728.76 | 21 | 14.39 | 2770 | 837 | 2.89 / 478.44 | 2 | 2 |
4 | 13 | 1001.00 | 21 | 14.57 | 1772 | 542 | 3.43 / 478.98 | 2 | 3 |
5 | 13 | 266.00 | 21 | 14.90 | 708 | 222 | 3.65 / 479.20 | 2 | 2 |
6 | 8 | -0.12 | 170 | 14.95 | 316 | 803 | 4.46 / 480.01 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 28 | 15.16 | 459 | 195 | 0.19 / 471.30 | 2 | 2 |
2 | 7 | 2003.40 | 41 | 14.41 | 3115 | 1840 | 2.04 / 473.14 | 2 | 2 |
3 | 13 | 1731.64 | 21 | 14.38 | 2775 | 838 | 2.87 / 473.98 | 2 | 3 |
4 | 13 | 1003.00 | 21 | 14.57 | 1781 | 545 | 3.42 / 474.52 | 2 | 6 |
5 | 13 | 272.72 | 21 | 14.89 | 723 | 226 | 3.64 / 474.75 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.95 | 315 | 801 | 4.44 / 475.55 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 28 | 15.16 | 451 | 191 | 0.19 / 466.94 | 2 | 2 |
2 | 7 | 2006.72 | 41 | 14.40 | 3122 | 1843 | 2.03 / 468.78 | 2 | 2 |
3 | 13 | 1592.24 | 21 | 14.41 | 2595 | 785 | 2.82 / 469.57 | 2 | 3 |
4 | 13 | 1023.84 | 21 | 14.55 | 1808 | 552 | 3.37 / 470.12 | 2 | 4 |
5 | 13 | 168.96 | 21 | 14.94 | 577 | 181 | 3.55 / 470.30 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.96 | 317 | 806 | 4.36 / 471.10 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 28 | 14.93 | 459 | 192 | 0.19 / 462.54 | 2 | 2 |
2 | 7 | 2003.80 | 42 | 14.41 | 3120 | 1888 | 2.08 / 464.42 | 2 | 2 |
3 | 13 | 1605.28 | 21 | 14.41 | 2598 | 786 | 2.87 / 465.21 | 2 | 4 |
4 | 13 | 1027.04 | 21 | 14.56 | 1818 | 556 | 3.42 / 465.77 | 2 | 6 |
5 | 13 | 150.44 | 21 | 14.95 | 550 | 173 | 3.59 / 465.94 | 2 | 2 |
6 | 8 | 0.40 | 170 | 14.96 | 317 | 806 | 4.40 / 466.75 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 14.94 | 469 | 196 | 0.20 / 458.09 | 2 | 2 |
2 | 7 | 2006.84 | 42 | 14.41 | 3117 | 1886 | 2.08 / 459.98 | 2 | 2 |
3 | 13 | 1589.80 | 21 | 14.43 | 2580 | 782 | 2.86 / 460.76 | 2 | 3 |
4 | 13 | 1022.56 | 21 | 14.56 | 1808 | 553 | 3.42 / 461.31 | 2 | 4 |
5 | 13 | 290.20 | 21 | 14.89 | 748 | 234 | 3.65 / 461.55 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.95 | 313 | 795 | 4.45 / 462.34 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 28 | 15.18 | 449 | 191 | 0.19 / 453.72 | 2 | 2 |
2 | 7 | 2007.76 | 41 | 14.41 | 3127 | 1847 | 2.04 / 455.57 | 2 | 2 |
3 | 13 | 1613.64 | 21 | 14.41 | 2603 | 788 | 2.83 / 456.36 | 2 | 4 |
4 | 13 | 1038.28 | 21 | 14.55 | 1825 | 558 | 3.38 / 456.91 | 2 | 3 |
5 | 13 | 177.84 | 21 | 14.94 | 590 | 185 | 3.57 / 457.10 | 2 | 2 |
6 | 8 | -0.08 | 170 | 14.95 | 314 | 798 | 4.37 / 457.90 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 28 | 15.18 | 448 | 190 | 0.19 / 449.37 | 2 | 2 |
2 | 7 | 2007.72 | 41 | 14.41 | 3132 | 1850 | 2.04 / 451.22 | 2 | 2 |
3 | 13 | 1602.68 | 21 | 14.41 | 2604 | 788 | 2.83 / 452.01 | 2 | 3 |
4 | 13 | 1031.32 | 21 | 14.55 | 1814 | 554 | 3.38 / 452.56 | 2 | 5 |
5 | 13 | 160.32 | 21 | 14.95 | 555 | 174 | 3.56 / 452.73 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.96 | 313 | 796 | 4.35 / 453.53 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 28 | 14.93 | 472 | 197 | 0.20 / 444.99 | 2 | 2 |
2 | 7 | 2002.84 | 42 | 14.42 | 3109 | 1883 | 2.08 / 446.87 | 2 | 2 |
3 | 13 | 1599.40 | 21 | 14.43 | 2594 | 786 | 2.87 / 447.66 | 2 | 4 |
4 | 13 | 1020.28 | 21 | 14.57 | 1804 | 552 | 3.42 / 448.21 | 2 | 5 |
5 | 13 | 140.08 | 21 | 14.96 | 527 | 166 | 3.58 / 448.37 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.96 | 316 | 804 | 4.39 / 449.18 | 2 | 10 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 28 | 14.94 | 461 | 193 | 0.19 / 440.54 | 2 | 2 |
2 | 7 | 2005.20 | 42 | 14.41 | 3114 | 1885 | 2.08 / 442.42 | 2 | 2 |
3 | 13 | 1596.68 | 21 | 14.42 | 2593 | 785 | 2.86 / 443.21 | 2 | 3 |
4 | 13 | 1027.00 | 21 | 14.56 | 1811 | 554 | 3.42 / 443.76 | 2 | 5 |
5 | 13 | 283.44 | 21 | 14.89 | 738 | 231 | 3.65 / 443.99 | 2 | 2 |
6 | 8 | 0.04 | 170 | 14.96 | 313 | 796 | 4.44 / 444.79 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 28 | 14.94 | 452 | 189 | 0.19 / 436.14 | 2 | 2 |
2 | 7 | 2003.12 | 42 | 14.41 | 3110 | 1882 | 2.07 / 438.02 | 2 | 3 |
3 | 13 | 1602.04 | 21 | 14.42 | 2603 | 788 | 2.86 / 438.81 | 2 | 3 |
4 | 13 | 1030.44 | 21 | 14.56 | 1810 | 553 | 3.41 / 439.36 | 2 | 5 |
5 | 13 | 168.76 | 21 | 14.95 | 574 | 180 | 3.59 / 439.54 | 2 | 2 |
6 | 8 | 0.32 | 170 | 14.97 | 317 | 807 | 4.40 / 440.35 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 28 | 14.94 | 478 | 200 | 0.20 / 431.67 | 2 | 2 |
2 | 7 | 2003.20 | 41 | 14.42 | 3131 | 1851 | 2.05 / 433.52 | 2 | 2 |
3 | 13 | 1735.44 | 21 | 14.39 | 2780 | 840 | 2.89 / 434.36 | 2 | 2 |
4 | 13 | 1024.04 | 21 | 14.58 | 1808 | 554 | 3.44 / 434.91 | 2 | 3 |
5 | 13 | 293.08 | 21 | 14.90 | 755 | 236 | 3.68 / 435.15 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.97 | 314 | 799 | 4.48 / 435.95 | 2 | 11 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 28 | 14.95 | 461 | 193 | 0.19 / 427.15 | 2 | 2 |
2 | 7 | 2003.72 | 41 | 14.41 | 3130 | 1849 | 2.04 / 429.00 | 2 | 2 |
3 | 13 | 1729.80 | 21 | 14.39 | 2769 | 837 | 2.88 / 429.83 | 2 | 3 |
4 | 13 | 1135.80 | 21 | 14.52 | 1972 | 601 | 3.48 / 430.44 | 2 | 3 |
5 | 13 | 252.72 | 21 | 14.92 | 700 | 219 | 3.70 / 430.65 | 2 | 2 |
6 | 8 | 0.16 | 170 | 14.97 | 319 | 812 | 4.51 / 431.47 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 28 | 14.95 | 458 | 192 | 0.19 / 422.77 | 2 | 2 |
2 | 7 | 2007.92 | 41 | 14.41 | 3135 | 1852 | 2.04 / 424.62 | 2 | 2 |
3 | 13 | 1597.28 | 21 | 14.43 | 2603 | 789 | 2.83 / 425.41 | 2 | 3 |
4 | 13 | 1024.00 | 21 | 14.57 | 1818 | 556 | 3.39 / 425.97 | 2 | 3 |
5 | 13 | 156.80 | 21 | 14.96 | 562 | 177 | 3.57 / 426.15 | 2 | 2 |
6 | 8 | -0.04 | 170 | 14.97 | 318 | 809 | 4.37 / 426.96 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 28 | 15.21 | 446 | 190 | 0.19 / 418.37 | 2 | 2 |
2 | 7 | 2003.32 | 41 | 14.41 | 3129 | 1849 | 2.04 / 420.21 | 2 | 2 |
3 | 13 | 1724.72 | 21 | 14.39 | 2765 | 836 | 2.87 / 421.05 | 2 | 3 |
4 | 13 | 1003.68 | 21 | 14.57 | 1786 | 546 | 3.42 / 421.60 | 2 | 2 |
5 | 13 | 146.44 | 21 | 14.96 | 548 | 172 | 3.59 / 421.77 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.97 | 319 | 812 | 4.40 / 422.58 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 28 | 14.95 | 464 | 194 | 0.19 / 414.00 | 2 | 2 |
2 | 7 | 2006.40 | 41 | 14.42 | 3133 | 1852 | 2.05 / 415.85 | 2 | 2 |
3 | 13 | 1591.72 | 21 | 14.43 | 2592 | 785 | 2.83 / 416.64 | 2 | 3 |
4 | 13 | 1018.72 | 21 | 14.57 | 1814 | 555 | 3.39 / 417.19 | 2 | 3 |
5 | 13 | 158.80 | 21 | 14.96 | 563 | 177 | 3.56 / 417.37 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.97 | 316 | 804 | 4.37 / 418.18 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 28 | 14.95 | 460 | 193 | 0.19 / 409.52 | 2 | 2 |
2 | 7 | 2004.28 | 41 | 14.42 | 3146 | 1860 | 2.05 / 411.38 | 2 | 2 |
3 | 13 | 1729.44 | 21 | 14.40 | 2771 | 838 | 2.89 / 412.21 | 2 | 4 |
4 | 13 | 1002.40 | 21 | 14.58 | 1791 | 548 | 3.44 / 412.76 | 2 | 4 |
5 | 13 | 279.72 | 21 | 14.90 | 750 | 235 | 3.67 / 413.00 | 2 | 2 |
6 | 8 | 0.08 | 170 | 14.97 | 319 | 812 | 4.49 / 413.81 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 28 | 14.96 | 453 | 190 | 0.19 / 405.00 | 2 | 2 |
2 | 7 | 2006.04 | 41 | 14.42 | 3143 | 1858 | 2.05 / 406.86 | 2 | 2 |
3 | 13 | 1599.20 | 21 | 14.43 | 2606 | 790 | 2.84 / 407.65 | 2 | 3 |
4 | 13 | 1025.60 | 21 | 14.57 | 1818 | 556 | 3.39 / 408.21 | 2 | 3 |
5 | 13 | 166.52 | 21 | 14.96 | 585 | 184 | 3.58 / 408.39 | 2 | 2 |
6 | 13 | 13.92 | 21 | 15.01 | 350 | 110 | 3.69 / 408.50 | 2 | 2 |
7 | 8 | 1.08 | 170 | 14.96 | 323 | 821 | 4.51 / 409.32 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 28 | 15.09 | 445 | 188 | 0.19 / 400.62 | 2 | 2 |
2 | 7 | 2002.28 | 41 | 14.42 | 3123 | 1846 | 2.03 / 402.46 | 2 | 2 |
3 | 13 | 1719.80 | 21 | 14.41 | 2758 | 835 | 2.87 / 403.30 | 2 | 3 |
4 | 13 | 995.76 | 21 | 14.59 | 1778 | 545 | 3.41 / 403.84 | 2 | 4 |
5 | 13 | 140.72 | 21 | 14.97 | 534 | 168 | 3.58 / 404.01 | 2 | 2 |
6 | 8 | 0.20 | 170 | 14.98 | 315 | 802 | 4.38 / 404.81 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 28 | 14.95 | 478 | 200 | 0.20 / 396.18 | 2 | 2 |
2 | 7 | 2002.72 | 41 | 14.42 | 3131 | 1851 | 2.05 / 398.03 | 2 | 2 |
3 | 13 | 1593.32 | 21 | 14.43 | 2599 | 788 | 2.84 / 398.82 | 2 | 3 |
4 | 13 | 1024.28 | 21 | 14.57 | 1821 | 557 | 3.40 / 399.38 | 2 | 2 |
5 | 13 | 291.60 | 21 | 14.90 | 763 | 239 | 3.63 / 399.61 | 2 | 2 |
6 | 8 | 0.04 | 170 | 14.97 | 320 | 814 | 4.45 / 400.43 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 28 | 14.95 | 455 | 190 | 0.19 / 391.78 | 2 | 2 |
2 | 7 | 2005.76 | 41 | 14.42 | 3138 | 1855 | 2.05 / 393.63 | 2 | 2 |
3 | 13 | 1600.36 | 21 | 14.43 | 2609 | 791 | 2.84 / 394.42 | 2 | 3 |
4 | 13 | 1032.00 | 21 | 14.57 | 1833 | 561 | 3.40 / 394.98 | 2 | 5 |
5 | 13 | 162.28 | 21 | 14.96 | 577 | 181 | 3.58 / 395.16 | 2 | 2 |
6 | 8 | -0.04 | 170 | 14.97 | 321 | 817 | 4.40 / 395.98 | 2 | 2 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 28 | 15.22 | 441 | 188 | 0.19 / 387.26 | 2 | 2 |
2 | 7 | 2001.92 | 41 | 14.42 | 3126 | 1848 | 2.04 / 389.11 | 2 | 2 |
3 | 13 | 1723.80 | 21 | 14.39 | 2774 | 838 | 2.87 / 389.95 | 2 | 3 |
4 | 13 | 994.96 | 21 | 14.58 | 1780 | 545 | 3.42 / 390.50 | 2 | 5 |
5 | 13 | 139.44 | 21 | 14.97 | 542 | 170 | 3.59 / 390.67 | 2 | 2 |
6 | 13 | 13.00 | 21 | 15.02 | 340 | 107 | 3.70 / 390.77 | 2 | 2 |
7 | 8 | -0.12 | 170 | 14.96 | 319 | 811 | 4.51 / 391.58 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 28 | 15.24 | 433 | 185 | 0.18 / 382.91 | 2 | 2 |
2 | 7 | 2003.80 | 41 | 14.41 | 3128 | 1848 | 2.03 / 384.76 | 2 | 2 |
3 | 13 | 1598.64 | 21 | 14.42 | 2605 | 789 | 2.82 / 385.55 | 2 | 3 |
4 | 13 | 1023.04 | 21 | 14.56 | 1812 | 554 | 3.38 / 386.10 | 2 | 3 |
5 | 13 | 162.44 | 21 | 14.96 | 565 | 178 | 3.55 / 386.28 | 2 | 2 |
6 | 8 | -0.04 | 170 | 14.97 | 313 | 797 | 4.35 / 387.08 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 28 | 15.23 | 454 | 194 | 0.19 / 378.54 | 2 | 2 |
2 | 7 | 2001.92 | 41 | 14.41 | 3122 | 1845 | 2.04 / 380.38 | 2 | 2 |
3 | 13 | 1728.64 | 21 | 14.39 | 2769 | 837 | 2.87 / 381.22 | 2 | 4 |
4 | 13 | 1005.88 | 21 | 14.59 | 1785 | 547 | 3.42 / 381.77 | 2 | 5 |
5 | 13 | 151.52 | 21 | 14.98 | 544 | 171 | 3.59 / 381.94 | 2 | 2 |
6 | 8 | -0.16 | 170 | 14.99 | 310 | 790 | 4.38 / 382.73 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 28 | 14.96 | 451 | 189 | 0.19 / 374.12 | 2 | 2 |
2 | 7 | 2003.12 | 42 | 14.41 | 3117 | 1886 | 2.08 / 376.00 | 2 | 2 |
3 | 13 | 1725.64 | 21 | 14.40 | 2764 | 836 | 2.91 / 376.84 | 2 | 4 |
4 | 13 | 1001.64 | 21 | 14.60 | 1780 | 546 | 3.46 / 377.38 | 2 | 3 |
5 | 13 | 142.56 | 21 | 14.99 | 527 | 166 | 3.62 / 377.55 | 2 | 2 |
6 | 8 | 0.28 | 170 | 15.00 | 311 | 793 | 4.42 / 378.34 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 28 | 14.96 | 452 | 189 | 0.19 / 369.61 | 2 | 2 |
2 | 3 | 1019.60 | 1 | 15.19 | 1820 | 28 | 0.22 / 369.64 | 2 | 2 |
3 | 7 | 2002.28 | 42 | 14.40 | 3121 | 1888 | 2.10 / 371.53 | 2 | 2 |
4 | 13 | 1726.84 | 21 | 14.39 | 2770 | 837 | 2.94 / 372.36 | 2 | 3 |
5 | 13 | 1007.84 | 21 | 14.59 | 1784 | 547 | 3.49 / 372.91 | 2 | 3 |
6 | 13 | 272.64 | 21 | 14.92 | 726 | 227 | 3.72 / 373.14 | 2 | 2 |
7 | 8 | -0.20 | 170 | 14.98 | 310 | 789 | 4.51 / 373.93 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 28 | 15.21 | 446 | 190 | 0.19 / 365.31 | 2 | 2 |
2 | 7 | 2003.72 | 41 | 14.40 | 3109 | 1836 | 2.03 / 367.14 | 2 | 2 |
3 | 13 | 1592.84 | 21 | 14.42 | 2593 | 785 | 2.81 / 367.93 | 2 | 4 |
4 | 13 | 1025.00 | 21 | 14.57 | 1829 | 560 | 3.37 / 368.49 | 2 | 4 |
5 | 13 | 87.36 | 21 | 15.00 | 451 | 142 | 3.51 / 368.63 | 2 | 2 |
6 | 8 | -0.08 | 170 | 14.98 | 311 | 792 | 4.30 / 369.42 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 28 | 15.21 | 457 | 195 | 0.19 / 360.91 | 2 | 2 |
2 | 7 | 2003.28 | 41 | 14.41 | 3116 | 1841 | 2.04 / 362.76 | 2 | 2 |
3 | 13 | 1591.72 | 21 | 14.43 | 2586 | 784 | 2.82 / 363.54 | 2 | 2 |
4 | 13 | 1022.96 | 21 | 14.56 | 1807 | 553 | 3.37 / 364.09 | 2 | 3 |
5 | 13 | 292.24 | 21 | 14.90 | 747 | 234 | 3.61 / 364.32 | 2 | 2 |
6 | 8 | -0.12 | 170 | 14.96 | 312 | 793 | 4.40 / 365.12 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 28 | 15.21 | 454 | 193 | 0.19 / 356.57 | 2 | 2 |
2 | 7 | 2003.20 | 41 | 14.41 | 3129 | 1849 | 2.04 / 358.42 | 2 | 3 |
3 | 13 | 1589.64 | 21 | 14.43 | 2583 | 783 | 2.82 / 359.20 | 2 | 4 |
4 | 13 | 1021.72 | 21 | 14.56 | 1812 | 554 | 3.38 / 359.75 | 2 | 4 |
5 | 13 | 162.72 | 21 | 14.97 | 560 | 176 | 3.55 / 359.93 | 2 | 2 |
6 | 8 | 0.00 | 170 | 14.98 | 310 | 789 | 4.34 / 360.72 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 28 | 14.96 | 456 | 191 | 0.19 / 352.23 | 2 | 2 |
2 | 7 | 2005.08 | 41 | 14.43 | 3109 | 1839 | 2.03 / 354.07 | 2 | 2 |
3 | 13 | 1595.72 | 21 | 14.43 | 2598 | 787 | 2.82 / 354.86 | 2 | 3 |
4 | 13 | 1025.68 | 21 | 14.57 | 1813 | 555 | 3.37 / 355.41 | 2 | 2 |
5 | 13 | 153.76 | 21 | 14.98 | 545 | 171 | 3.54 / 355.59 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.99 | 310 | 790 | 4.33 / 356.38 | 2 | 2 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 28 | 15.21 | 452 | 192 | 0.19 / 347.89 | 2 | 2 |
2 | 7 | 2002.56 | 41 | 14.42 | 3117 | 1843 | 2.04 / 349.73 | 2 | 2 |
3 | 13 | 1589.56 | 21 | 14.43 | 2587 | 784 | 2.82 / 350.52 | 2 | 3 |
4 | 13 | 1022.44 | 21 | 14.57 | 1802 | 551 | 3.37 / 351.07 | 2 | 4 |
5 | 13 | 156.92 | 21 | 14.97 | 565 | 178 | 3.55 / 351.24 | 2 | 2 |
6 | 8 | 0.04 | 170 | 14.98 | 313 | 797 | 4.35 / 352.04 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 28 | 15.21 | 445 | 190 | 0.19 / 343.55 | 2 | 2 |
2 | 7 | 2002.44 | 41 | 14.42 | 3111 | 1839 | 2.03 / 345.39 | 2 | 2 |
3 | 13 | 1592.28 | 21 | 14.43 | 2589 | 785 | 2.81 / 346.17 | 2 | 4 |
4 | 13 | 1019.20 | 21 | 14.57 | 1809 | 553 | 3.37 / 346.72 | 2 | 4 |
5 | 13 | 158.72 | 21 | 14.97 | 557 | 175 | 3.54 / 346.90 | 2 | 2 |
6 | 8 | 0.00 | 170 | 14.98 | 313 | 797 | 4.34 / 347.70 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 27 | 14.95 | 468 | 189 | 0.19 / 339.20 | 2 | 2 |
2 | 7 | 2002.48 | 41 | 14.42 | 3121 | 1845 | 2.03 / 341.04 | 2 | 2 |
3 | 13 | 1585.84 | 21 | 14.44 | 2594 | 787 | 2.82 / 341.83 | 2 | 3 |
4 | 13 | 1010.28 | 21 | 14.59 | 1792 | 549 | 3.37 / 342.38 | 2 | 4 |
5 | 13 | 141.12 | 21 | 14.99 | 533 | 168 | 3.54 / 342.55 | 2 | 2 |
6 | 8 | 0.00 | 170 | 14.99 | 318 | 810 | 4.35 / 343.36 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 27 | 15.20 | 465 | 191 | 0.19 / 334.74 | 2 | 2 |
2 | 7 | 2002.12 | 42 | 14.43 | 3105 | 1882 | 2.07 / 336.62 | 2 | 2 |
3 | 13 | 1593.24 | 21 | 14.43 | 2599 | 788 | 2.86 / 337.41 | 2 | 3 |
4 | 13 | 1018.56 | 21 | 14.57 | 1799 | 550 | 3.41 / 337.96 | 2 | 4 |
5 | 13 | 282.00 | 21 | 14.91 | 747 | 234 | 3.64 / 338.19 | 2 | 2 |
6 | 8 | -0.08 | 170 | 14.98 | 321 | 817 | 4.46 / 339.01 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 28 | 15.21 | 466 | 198 | 0.20 / 330.24 | 2 | 2 |
2 | 7 | 2002.64 | 41 | 14.42 | 3121 | 1845 | 2.04 / 332.09 | 2 | 2 |
3 | 13 | 1596.96 | 21 | 14.43 | 2602 | 788 | 2.83 / 332.87 | 2 | 4 |
4 | 13 | 1026.52 | 21 | 14.58 | 1812 | 555 | 3.39 / 333.43 | 2 | 3 |
5 | 13 | 437.88 | 21 | 14.84 | 973 | 303 | 3.69 / 333.73 | 2 | 2 |
6 | 8 | 0.12 | 170 | 14.98 | 320 | 815 | 4.51 / 334.55 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 28 | 14.97 | 474 | 199 | 0.20 / 325.86 | 2 | 2 |
2 | 7 | 2005.96 | 41 | 14.43 | 3125 | 1849 | 2.05 / 327.71 | 2 | 2 |
3 | 13 | 1595.00 | 21 | 14.44 | 2602 | 789 | 2.84 / 328.50 | 2 | 3 |
4 | 13 | 1025.16 | 21 | 14.59 | 1814 | 556 | 3.39 / 329.06 | 2 | 4 |
5 | 13 | 151.60 | 21 | 14.99 | 555 | 175 | 3.57 / 329.23 | 2 | 2 |
6 | 8 | 0.24 | 170 | 15.00 | 318 | 811 | 4.38 / 330.04 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 28 | 14.97 | 474 | 199 | 0.20 / 321.35 | 2 | 2 |
2 | 7 | 2003.92 | 41 | 14.44 | 3107 | 1839 | 2.04 / 323.19 | 2 | 2 |
3 | 13 | 1589.96 | 21 | 14.45 | 2586 | 785 | 2.82 / 323.98 | 2 | 3 |
4 | 13 | 1005.24 | 21 | 14.60 | 1772 | 543 | 3.37 / 324.52 | 2 | 4 |
5 | 13 | 268.08 | 21 | 14.93 | 730 | 229 | 3.60 / 324.75 | 2 | 2 |
6 | 8 | 0.48 | 170 | 14.99 | 322 | 821 | 4.42 / 325.57 | 2 | 4 |
7 | 14 | 0.48 | 20 | 14.96 | 316 | 95 | 4.51 / 325.66 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 28 | 14.97 | 476 | 200 | 0.20 / 316.97 | 2 | 2 |
2 | 7 | 2003.44 | 41 | 14.44 | 3122 | 1848 | 2.05 / 318.82 | 2 | 2 |
3 | 13 | 1603.52 | 21 | 14.45 | 2605 | 790 | 2.84 / 319.61 | 2 | 3 |
4 | 13 | 1024.64 | 21 | 14.59 | 1814 | 556 | 3.39 / 320.17 | 2 | 5 |
5 | 13 | 164.52 | 21 | 14.99 | 572 | 180 | 3.57 / 320.35 | 2 | 2 |
6 | 8 | 0.00 | 170 | 15.00 | 317 | 808 | 4.38 / 321.15 | 2 | 4 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 28 | 14.97 | 463 | 194 | 0.19 / 312.48 | 2 | 2 |
2 | 7 | 2005.48 | 41 | 14.44 | 3131 | 1854 | 2.05 / 314.34 | 2 | 2 |
3 | 13 | 1730.64 | 21 | 14.42 | 2770 | 839 | 2.89 / 315.17 | 2 | 3 |
4 | 13 | 999.28 | 21 | 14.61 | 1787 | 548 | 3.43 / 315.72 | 2 | 3 |
5 | 13 | 275.00 | 21 | 14.94 | 742 | 233 | 3.67 / 315.96 | 2 | 2 |
6 | 8 | 0.04 | 170 | 15.00 | 320 | 816 | 4.48 / 316.77 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 27 | 14.98 | 451 | 182 | 0.18 / 308.01 | 2 | 2 |
2 | 7 | 2005.04 | 41 | 14.46 | 3118 | 1849 | 2.03 / 309.86 | 2 | 2 |
3 | 13 | 1735.16 | 21 | 14.43 | 2788 | 845 | 2.88 / 310.70 | 2 | 3 |
4 | 13 | 1008.12 | 21 | 14.62 | 1789 | 549 | 3.43 / 311.25 | 2 | 4 |
5 | 13 | 277.64 | 21 | 14.94 | 731 | 229 | 3.65 / 311.48 | 2 | 2 |
6 | 8 | 0.00 | 170 | 15.00 | 317 | 808 | 4.46 / 312.29 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 27 | 15.22 | 449 | 185 | 0.18 / 303.68 | 2 | 2 |
2 | 7 | 2003.72 | 41 | 14.44 | 3130 | 1853 | 2.04 / 305.53 | 2 | 2 |
3 | 13 | 1583.20 | 21 | 14.46 | 2574 | 782 | 2.82 / 306.31 | 2 | 3 |
4 | 13 | 1002.36 | 21 | 14.61 | 1778 | 546 | 3.36 / 306.86 | 2 | 3 |
5 | 13 | 135.60 | 21 | 15.00 | 525 | 165 | 3.53 / 307.02 | 2 | 2 |
6 | 8 | 0.28 | 170 | 15.00 | 315 | 803 | 4.33 / 307.83 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 28 | 15.21 | 461 | 196 | 0.20 / 299.29 | 2 | 2 |
2 | 7 | 2005.92 | 42 | 14.44 | 3123 | 1894 | 2.09 / 301.18 | 2 | 2 |
3 | 13 | 1596.88 | 21 | 14.46 | 2591 | 787 | 2.88 / 301.97 | 2 | 3 |
4 | 13 | 1021.00 | 21 | 14.60 | 1809 | 555 | 3.43 / 302.52 | 2 | 3 |
5 | 13 | 151.36 | 21 | 15.00 | 538 | 169 | 3.60 / 302.69 | 2 | 2 |
6 | 8 | 0.00 | 170 | 15.01 | 313 | 799 | 4.40 / 303.49 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 27 | 14.98 | 461 | 186 | 0.19 / 294.80 | 2 | 2 |
2 | 7 | 2005.20 | 42 | 14.46 | 3120 | 1895 | 2.08 / 296.70 | 2 | 2 |
3 | 13 | 1585.48 | 21 | 14.48 | 2555 | 777 | 2.86 / 297.48 | 2 | 3 |
4 | 13 | 1144.72 | 21 | 14.56 | 1964 | 601 | 3.46 / 298.08 | 2 | 5 |
5 | 13 | 250.76 | 21 | 14.96 | 697 | 219 | 3.68 / 298.30 | 2 | 2 |
6 | 8 | -0.04 | 170 | 15.01 | 312 | 796 | 4.47 / 299.09 | 2 | 3 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 27 | 15.23 | 446 | 183 | 0.18 / 290.33 | 2 | 2 |
2 | 7 | 2006.12 | 42 | 14.45 | 3116 | 1891 | 2.07 / 292.22 | 2 | 2 |
3 | 13 | 1603.04 | 21 | 14.47 | 2600 | 790 | 2.86 / 293.01 | 2 | 3 |
4 | 13 | 1031.24 | 21 | 14.61 | 1821 | 559 | 3.42 / 293.57 | 2 | 4 |
5 | 13 | 304.64 | 21 | 14.93 | 779 | 244 | 3.67 / 293.81 | 2 | 2 |
6 | 8 | -0.08 | 170 | 15.01 | 316 | 806 | 4.47 / 294.62 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 27 | 15.01 | 462 | 187 | 0.19 / 285.88 | 2 | 2 |
2 | 7 | 2004.24 | 42 | 14.46 | 3123 | 1897 | 2.08 / 287.78 | 2 | 2 |
3 | 13 | 1730.00 | 21 | 14.45 | 2758 | 837 | 2.92 / 288.61 | 2 | 3 |
4 | 13 | 1002.92 | 21 | 14.64 | 1783 | 548 | 3.47 / 289.16 | 2 | 5 |
5 | 13 | 145.24 | 21 | 15.02 | 539 | 170 | 3.64 / 289.33 | 2 | 2 |
6 | 8 | 0.00 | 170 | 15.03 | 318 | 813 | 4.45 / 290.14 | 2 | 3 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 27 | 15.25 | 455 | 187 | 0.19 / 281.56 | 2 | 2 |
2 | 7 | 2003.28 | 41 | 14.46 | 3120 | 1850 | 2.04 / 283.41 | 2 | 2 |
3 | 13 | 1596.08 | 21 | 14.48 | 2597 | 790 | 2.83 / 284.20 | 2 | 3 |
4 | 13 | 899.32 | 21 | 14.68 | 1635 | 504 | 3.33 / 284.70 | 2 | 3 |
5 | 13 | 181.60 | 21 | 15.00 | 601 | 189 | 3.52 / 284.89 | 2 | 2 |
6 | 8 | 0.32 | 170 | 15.03 | 314 | 802 | 4.32 / 285.69 | 2 | 5 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 27 | 15.07 | 458 | 186 | 0.19 / 276.98 | 2 | 2 |
2 | 7 | 2005.00 | 42 | 14.46 | 3132 | 1902 | 2.09 / 278.88 | 2 | 2 |
3 | 13 | 1591.36 | 29 | 14.46 | 2595 | 1088 | 3.18 / 279.97 | 2 | 3 |
4 | 13 | 711.68 | 29 | 14.76 | 1358 | 581 | 3.76 / 280.55 | 2 | 3 |
5 | 8 | 0.24 | 170 | 15.03 | 321 | 820 | 4.58 / 281.37 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 27 | 15.27 | 428 | 176 | 0.18 / 272.25 | 2 | 2 |
2 | 7 | 2005.00 | 41 | 14.47 | 3121 | 1852 | 2.03 / 274.10 | 2 | 2 |
3 | 13 | 1599.24 | 29 | 14.46 | 2581 | 1082 | 3.11 / 275.18 | 2 | 3 |
4 | 13 | 847.08 | 29 | 14.69 | 1541 | 656 | 3.77 / 275.84 | 2 | 3 |
5 | 13 | 16.92 | 29 | 15.07 | 340 | 149 | 3.92 / 275.99 | 2 | 2 |
6 | 8 | -0.20 | 170 | 15.01 | 315 | 804 | 4.72 / 276.79 | 2 | 6 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 27 | 15.01 | 453 | 184 | 0.18 / 267.89 | 2 | 2 |
2 | 7 | 2002.16 | 41 | 14.48 | 3114 | 1849 | 2.03 / 269.73 | 2 | 2 |
3 | 13 | 1474.64 | 29 | 14.51 | 2415 | 1016 | 3.05 / 270.75 | 2 | 3 |
4 | 13 | 616.24 | 29 | 14.82 | 1225 | 526 | 3.57 / 271.28 | 2 | 3 |
5 | 8 | 0.16 | 170 | 15.05 | 311 | 796 | 4.37 / 272.07 | 2 | 5 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 27 | 15.02 | 440 | 178 | 0.18 / 263.11 | 2 | 2 |
2 | 3 | 1021.92 | 1 | 15.21 | 1828 | 28 | 0.21 / 263.14 | 2 | 2 |
3 | 7 | 2001.48 | 41 | 14.49 | 3111 | 1848 | 2.05 / 264.99 | 2 | 2 |
4 | 13 | 1592.96 | 29 | 14.48 | 2571 | 1080 | 3.13 / 266.07 | 2 | 3 |
5 | 13 | 839.52 | 29 | 14.71 | 1543 | 658 | 3.79 / 266.73 | 2 | 4 |
6 | 13 | 38.96 | 29 | 15.07 | 382 | 167 | 3.96 / 266.89 | 2 | 2 |
7 | 8 | 0.00 | 170 | 15.03 | 317 | 810 | 4.77 / 267.70 | 2 | 6 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 27 | 15.29 | 428 | 177 | 0.18 / 258.39 | 2 | 2 |
2 | 7 | 2001.96 | 42 | 14.47 | 3128 | 1901 | 2.08 / 260.29 | 2 | 3 |
3 | 13 | 1580.44 | 29 | 14.48 | 2566 | 1078 | 3.16 / 261.37 | 2 | 2 |
4 | 13 | 812.76 | 29 | 14.72 | 1493 | 637 | 3.79 / 262.00 | 2 | 3 |
5 | 13 | 15.84 | 29 | 15.09 | 328 | 144 | 3.94 / 262.15 | 2 | 2 |
6 | 8 | -0.08 | 170 | 15.03 | 307 | 784 | 4.72 / 262.93 | 2 | 5 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 27 | 15.30 | 418 | 173 | 0.17 / 253.76 | 2 | 2 |
2 | 7 | 2001.28 | 42 | 14.48 | 3115 | 1894 | 2.07 / 255.66 | 2 | 2 |
3 | 13 | 1590.96 | 29 | 14.49 | 2580 | 1084 | 3.15 / 256.74 | 2 | 3 |
4 | 13 | 832.56 | 29 | 14.73 | 1525 | 651 | 3.80 / 257.39 | 2 | 3 |
5 | 8 | 0.04 | 170 | 15.05 | 320 | 819 | 4.62 / 258.21 | 2 | 4 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 27 | 15.30 | 423 | 175 | 0.17 / 249.26 | 2 | 2 |
2 | 7 | 2001.72 | 42 | 14.49 | 3110 | 1893 | 2.07 / 251.15 | 2 | 2 |
3 | 13 | 1584.92 | 29 | 14.50 | 2570 | 1081 | 3.15 / 252.24 | 2 | 3 |
4 | 13 | 692.68 | 29 | 14.80 | 1326 | 569 | 3.72 / 252.80 | 2 | 3 |
5 | 8 | -0.08 | 170 | 15.07 | 307 | 787 | 4.50 / 253.59 | 2 | 7 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 27 | 15.04 | 452 | 184 | 0.18 / 244.79 | 2 | 2 |
2 | 7 | 2004.28 | 41 | 14.49 | 3120 | 1854 | 2.04 / 246.64 | 2 | 2 |
3 | 13 | 1600.84 | 29 | 14.50 | 2598 | 1092 | 3.13 / 247.73 | 2 | 3 |
4 | 13 | 697.80 | 29 | 14.81 | 1334 | 573 | 3.70 / 248.31 | 2 | 3 |
5 | 8 | 0.12 | 170 | 15.08 | 305 | 782 | 4.48 / 249.09 | 2 | 4 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 27 | 15.31 | 424 | 175 | 0.18 / 240.08 | 2 | 2 |
2 | 7 | 2001.36 | 42 | 14.49 | 3120 | 1899 | 2.07 / 241.97 | 2 | 2 |
3 | 13 | 1596.72 | 29 | 14.51 | 2580 | 1086 | 3.16 / 243.06 | 2 | 2 |
4 | 13 | 704.36 | 29 | 14.81 | 1358 | 583 | 3.74 / 243.64 | 2 | 3 |
5 | 13 | 28.12 | 29 | 15.10 | 364 | 159 | 3.90 / 243.80 | 2 | 2 |
6 | 8 | 0.20 | 170 | 15.05 | 313 | 801 | 4.70 / 244.60 | 2 | 6 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 27 | 15.31 | 423 | 175 | 0.17 / 235.44 | 2 | 2 |
2 | 7 | 2005.80 | 41 | 14.49 | 3109 | 1847 | 2.02 / 237.29 | 2 | 2 |
3 | 13 | 1595.28 | 29 | 14.51 | 2586 | 1088 | 3.11 / 238.38 | 2 | 3 |
4 | 13 | 702.72 | 29 | 14.82 | 1342 | 577 | 3.69 / 238.96 | 2 | 2 |
5 | 13 | 18.40 | 29 | 15.11 | 341 | 149 | 3.84 / 239.11 | 2 | 2 |
6 | 8 | 0.16 | 170 | 15.06 | 310 | 794 | 4.63 / 239.90 | 2 | 7 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 27 | 15.32 | 417 | 172 | 0.17 / 230.78 | 2 | 2 |
2 | 7 | 2003.36 | 42 | 14.50 | 3111 | 1895 | 2.07 / 232.67 | 2 | 2 |
3 | 13 | 1590.16 | 29 | 14.52 | 2565 | 1080 | 3.15 / 233.75 | 2 | 3 |
4 | 13 | 690.00 | 29 | 14.84 | 1328 | 572 | 3.72 / 234.32 | 2 | 3 |
5 | 13 | 34.52 | 29 | 15.11 | 364 | 160 | 3.88 / 234.48 | 2 | 2 |
6 | 8 | -0.08 | 170 | 15.07 | 308 | 789 | 4.67 / 235.27 | 2 | 5 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 27 | 15.32 | 428 | 177 | 0.18 / 226.30 | 2 | 2 |
2 | 7 | 2003.08 | 41 | 14.50 | 3124 | 1857 | 2.03 / 228.16 | 2 | 2 |
3 | 13 | 1594.60 | 29 | 14.52 | 2574 | 1084 | 3.12 / 229.25 | 2 | 3 |
4 | 13 | 701.40 | 29 | 14.83 | 1348 | 580 | 3.70 / 229.83 | 2 | 3 |
5 | 8 | 0.04 | 170 | 15.09 | 303 | 777 | 4.48 / 230.60 | 2 | 6 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 27 | 15.09 | 445 | 181 | 0.18 / 221.96 | 2 | 2 |
2 | 7 | 1818.92 | 42 | 14.57 | 2876 | 1760 | 1.94 / 223.72 | 2 | 2 |
3 | 13 | 1549.32 | 29 | 14.56 | 2513 | 1061 | 3.00 / 224.78 | 2 | 5 |
4 | 13 | 661.16 | 29 | 14.86 | 1288 | 555 | 3.56 / 225.33 | 2 | 3 |
5 | 8 | 0.20 | 170 | 15.10 | 309 | 793 | 4.35 / 226.13 | 2 | 4 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 27 | 15.08 | 452 | 184 | 0.18 / 218.00 | 2 | 2 |
2 | 7 | 1538.52 | 41 | 14.69 | 2503 | 1508 | 1.69 / 219.50 | 2 | 2 |
3 | 13 | 1416.40 | 29 | 14.63 | 2351 | 997 | 2.69 / 220.50 | 2 | 4 |
4 | 13 | 538.20 | 29 | 14.93 | 1111 | 481 | 3.17 / 220.98 | 2 | 3 |
5 | 8 | -0.04 | 170 | 15.11 | 309 | 794 | 3.96 / 221.78 | 2 | 5 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 27 | 15.10 | 438 | 179 | 0.18 / 213.72 | 2 | 2 |
2 | 7 | 1786.20 | 41 | 14.58 | 2833 | 1694 | 1.87 / 215.41 | 2 | 3 |
3 | 13 | 1523.76 | 29 | 14.58 | 2483 | 1050 | 2.92 / 216.46 | 2 | 5 |
4 | 13 | 617.24 | 29 | 14.89 | 1239 | 535 | 3.46 / 217.00 | 2 | 3 |
5 | 8 | -0.04 | 170 | 15.10 | 317 | 814 | 4.27 / 217.81 | 2 | 3 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 27 | 15.09 | 466 | 190 | 0.19 / 210.08 | 2 | 2 |
2 | 7 | 1308.28 | 42 | 14.80 | 2188 | 1360 | 1.55 / 211.44 | 2 | 2 |
3 | 13 | 1195.04 | 29 | 14.75 | 2025 | 866 | 2.42 / 212.30 | 2 | 5 |
4 | 13 | 480.28 | 29 | 14.98 | 1034 | 449 | 2.87 / 212.75 | 2 | 2 |
5 | 8 | 0.04 | 170 | 15.13 | 307 | 790 | 3.65 / 213.54 | 2 | 10 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 27 | 15.10 | 453 | 185 | 0.18 / 205.75 | 2 | 2 |
2 | 7 | 1741.56 | 42 | 14.61 | 2773 | 1702 | 1.89 / 207.45 | 2 | 2 |
3 | 13 | 1484.68 | 29 | 14.60 | 2444 | 1035 | 2.92 / 208.49 | 2 | 3 |
4 | 13 | 717.20 | 29 | 14.85 | 1372 | 591 | 3.51 / 209.08 | 2 | 3 |
5 | 8 | 0.24 | 170 | 15.11 | 315 | 809 | 4.32 / 209.89 | 2 | 5 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 27 | 15.10 | 442 | 180 | 0.18 / 201.94 | 2 | 2 |
2 | 7 | 1457.84 | 41 | 14.74 | 2393 | 1446 | 1.63 / 203.39 | 2 | 4 |
3 | 13 | 1342.92 | 29 | 14.69 | 2231 | 950 | 2.58 / 204.34 | 2 | 4 |
4 | 13 | 463.40 | 29 | 14.99 | 999 | 434 | 3.01 / 204.77 | 2 | 2 |
5 | 8 | -0.36 | 170 | 15.13 | 309 | 795 | 3.81 / 205.57 | 2 | 6 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 27 | 15.10 | 466 | 190 | 0.19 / 197.67 | 2 | 2 |
2 | 7 | 1757.68 | 41 | 14.62 | 2795 | 1675 | 1.87 / 199.34 | 2 | 2 |
3 | 13 | 1494.96 | 29 | 14.61 | 2445 | 1036 | 2.90 / 200.38 | 2 | 5 |
4 | 13 | 736.56 | 29 | 14.85 | 1398 | 602 | 3.50 / 200.98 | 2 | 3 |
5 | 8 | -0.20 | 170 | 15.13 | 303 | 779 | 4.28 / 201.76 | 2 | 5 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 27 | 15.09 | 486 | 198 | 0.20 / 193.08 | 2 | 2 |
2 | 7 | 2003.76 | 41 | 14.53 | 3115 | 1856 | 2.05 / 194.94 | 2 | 2 |
3 | 13 | 1727.44 | 29 | 14.53 | 2752 | 1160 | 3.21 / 196.10 | 2 | 3 |
4 | 13 | 687.96 | 29 | 14.89 | 1333 | 576 | 3.79 / 196.68 | 2 | 3 |
5 | 8 | -0.12 | 170 | 15.13 | 312 | 802 | 4.59 / 197.48 | 2 | 6 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 27 | 15.10 | 474 | 193 | 0.19 / 188.52 | 2 | 2 |
2 | 7 | 2001.80 | 41 | 14.53 | 3123 | 1860 | 2.05 / 190.38 | 2 | 2 |
3 | 13 | 1589.64 | 29 | 14.58 | 2578 | 1090 | 3.14 / 191.47 | 2 | 4 |
4 | 13 | 695.68 | 29 | 14.88 | 1356 | 585 | 3.73 / 192.05 | 2 | 4 |
5 | 8 | -0.04 | 170 | 15.12 | 325 | 835 | 4.56 / 192.89 | 2 | 5 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 27 | 15.12 | 472 | 193 | 0.19 / 183.95 | 2 | 2 |
2 | 7 | 2002.76 | 41 | 14.54 | 3116 | 1858 | 2.05 / 185.80 | 2 | 2 |
3 | 13 | 1594.56 | 29 | 14.58 | 2584 | 1093 | 3.14 / 186.90 | 2 | 3 |
4 | 13 | 706.84 | 29 | 14.88 | 1374 | 593 | 3.74 / 187.49 | 2 | 3 |
5 | 8 | 0.32 | 170 | 15.13 | 324 | 833 | 4.57 / 188.32 | 2 | 4 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 27 | 15.11 | 468 | 191 | 0.19 / 179.23 | 2 | 2 |
2 | 7 | 2003.16 | 41 | 14.54 | 3112 | 1855 | 2.05 / 181.08 | 2 | 2 |
3 | 13 | 1594.16 | 29 | 14.59 | 2581 | 1092 | 3.14 / 182.17 | 2 | 3 |
4 | 13 | 840.24 | 29 | 14.82 | 1543 | 663 | 3.80 / 182.84 | 2 | 3 |
5 | 8 | -0.16 | 190 | 15.13 | 319 | 917 | 4.72 / 183.75 | 2 | 13 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 27 | 15.12 | 471 | 192 | 0.19 / 174.54 | 2 | 2 |
2 | 7 | 2001.68 | 41 | 14.53 | 3139 | 1870 | 2.06 / 176.41 | 2 | 2 |
3 | 13 | 1590.68 | 29 | 14.58 | 2586 | 1093 | 3.16 / 177.50 | 2 | 2 |
4 | 13 | 703.16 | 29 | 14.89 | 1362 | 588 | 3.74 / 178.09 | 2 | 4 |
5 | 8 | -0.04 | 190 | 15.13 | 328 | 943 | 4.69 / 179.03 | 2 | 8 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 27 | 15.12 | 481 | 196 | 0.20 / 169.89 | 2 | 2 |
2 | 7 | 2003.80 | 41 | 14.54 | 3130 | 1866 | 2.06 / 171.76 | 2 | 2 |
3 | 13 | 1581.64 | 29 | 14.60 | 2569 | 1088 | 3.15 / 172.85 | 2 | 4 |
4 | 13 | 684.20 | 29 | 14.91 | 1326 | 573 | 3.72 / 173.42 | 2 | 3 |
5 | 8 | 0.04 | 190 | 15.14 | 322 | 926 | 4.65 / 174.35 | 2 | 5 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 27 | 15.11 | 473 | 193 | 0.19 / 165.24 | 2 | 2 |
2 | 7 | 2004.16 | 41 | 14.54 | 3122 | 1861 | 2.05 / 167.10 | 2 | 2 |
3 | 13 | 1584.32 | 29 | 14.60 | 2568 | 1087 | 3.14 / 168.19 | 2 | 2 |
4 | 13 | 689.96 | 29 | 14.91 | 1334 | 577 | 3.72 / 168.77 | 2 | 3 |
5 | 8 | -0.04 | 190 | 15.14 | 324 | 932 | 4.65 / 169.70 | 2 | 7 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 27 | 15.13 | 458 | 187 | 0.19 / 160.52 | 2 | 2 |
2 | 7 | 2005.12 | 41 | 14.55 | 3129 | 1867 | 2.05 / 162.38 | 2 | 2 |
3 | 13 | 1464.44 | 29 | 14.64 | 2398 | 1018 | 3.07 / 163.40 | 2 | 4 |
4 | 13 | 718.88 | 29 | 14.89 | 1373 | 593 | 3.66 / 163.99 | 2 | 3 |
5 | 13 | 14.84 | 29 | 15.18 | 338 | 149 | 3.81 / 164.14 | 2 | 2 |
6 | 8 | -0.04 | 190 | 15.12 | 315 | 905 | 4.72 / 165.05 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 27 | 15.12 | 467 | 191 | 0.19 / 155.91 | 2 | 2 |
2 | 7 | 2003.16 | 41 | 14.55 | 3117 | 1859 | 2.05 / 157.77 | 2 | 2 |
3 | 13 | 1585.56 | 29 | 14.61 | 2561 | 1085 | 3.14 / 158.85 | 2 | 3 |
4 | 13 | 685.16 | 29 | 14.92 | 1320 | 571 | 3.71 / 159.42 | 2 | 3 |
5 | 8 | 0.12 | 190 | 15.14 | 315 | 906 | 4.61 / 160.33 | 2 | 6 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 27 | 15.13 | 460 | 188 | 0.19 / 151.00 | 2 | 2 |
2 | 7 | 2002.84 | 41 | 14.56 | 3126 | 1866 | 2.05 / 152.87 | 2 | 2 |
3 | 13 | 1588.40 | 29 | 14.61 | 2567 | 1088 | 3.14 / 153.96 | 2 | 3 |
4 | 13 | 831.16 | 29 | 14.85 | 1535 | 661 | 3.80 / 154.62 | 2 | 3 |
5 | 13 | 80.96 | 29 | 15.16 | 439 | 193 | 4.00 / 154.81 | 2 | 2 |
6 | 8 | 0.04 | 190 | 15.13 | 315 | 906 | 4.90 / 155.72 | 2 | 11 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 27 | 15.15 | 454 | 186 | 0.19 / 146.37 | 2 | 2 |
2 | 7 | 2003.40 | 41 | 14.56 | 3129 | 1868 | 2.05 / 148.23 | 2 | 2 |
3 | 13 | 1591.40 | 29 | 14.61 | 2590 | 1097 | 3.15 / 149.33 | 2 | 4 |
4 | 13 | 692.16 | 29 | 14.92 | 1329 | 575 | 3.73 / 149.91 | 2 | 3 |
5 | 8 | 0.40 | 190 | 15.15 | 316 | 910 | 4.64 / 150.82 | 2 | 5 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 27 | 15.13 | 455 | 186 | 0.19 / 141.74 | 2 | 2 |
2 | 7 | 2003.12 | 39 | 14.58 | 3122 | 1775 | 1.96 / 143.51 | 2 | 3 |
3 | 13 | 1598.88 | 29 | 14.62 | 2590 | 1098 | 3.06 / 144.61 | 2 | 2 |
4 | 13 | 847.28 | 29 | 14.85 | 1559 | 671 | 3.73 / 145.28 | 2 | 3 |
5 | 8 | -0.12 | 190 | 15.16 | 312 | 899 | 4.63 / 146.18 | 2 | 14 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 27 | 15.15 | 459 | 188 | 0.19 / 136.89 | 2 | 2 |
2 | 7 | 2004.60 | 39 | 14.58 | 3134 | 1782 | 1.97 / 138.67 | 2 | 2 |
3 | 13 | 1737.12 | 29 | 14.58 | 2776 | 1174 | 3.14 / 139.84 | 2 | 2 |
4 | 13 | 815.24 | 29 | 14.87 | 1510 | 651 | 3.79 / 140.49 | 2 | 3 |
5 | 13 | 16.44 | 29 | 15.20 | 337 | 149 | 3.94 / 140.64 | 2 | 2 |
6 | 8 | -0.08 | 190 | 15.14 | 316 | 909 | 4.85 / 141.55 | 2 | 10 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 27 | 15.15 | 474 | 194 | 0.19 / 132.20 | 2 | 2 |
2 | 7 | 2002.68 | 39 | 14.58 | 3136 | 1783 | 1.98 / 133.98 | 2 | 2 |
3 | 13 | 1723.80 | 29 | 14.59 | 2757 | 1167 | 3.14 / 135.15 | 2 | 3 |
4 | 13 | 807.60 | 29 | 14.88 | 1499 | 647 | 3.79 / 135.80 | 2 | 3 |
5 | 8 | -0.08 | 190 | 15.17 | 313 | 902 | 4.69 / 136.70 | 2 | 6 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 27 | 15.15 | 448 | 183 | 0.18 / 127.64 | 2 | 2 |
2 | 7 | 2002.28 | 39 | 14.58 | 3127 | 1778 | 1.96 / 129.41 | 2 | 2 |
3 | 13 | 1601.12 | 29 | 14.63 | 2602 | 1104 | 3.07 / 130.52 | 2 | 3 |
4 | 13 | 715.08 | 29 | 14.93 | 1362 | 590 | 3.65 / 131.11 | 2 | 3 |
5 | 8 | 0.12 | 190 | 15.17 | 312 | 899 | 4.55 / 132.01 | 2 | 7 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 27 | 15.15 | 452 | 185 | 0.18 / 122.93 | 2 | 2 |
2 | 7 | 2003.48 | 39 | 14.58 | 3139 | 1785 | 1.97 / 124.71 | 2 | 2 |
3 | 13 | 1600.56 | 29 | 14.63 | 2590 | 1099 | 3.07 / 125.81 | 2 | 3 |
4 | 13 | 726.52 | 29 | 14.92 | 1385 | 599 | 3.67 / 126.41 | 2 | 3 |
5 | 13 | 16.76 | 29 | 15.21 | 337 | 149 | 3.82 / 126.56 | 2 | 2 |
6 | 8 | -0.04 | 190 | 15.15 | 310 | 892 | 4.71 / 127.45 | 2 | 9 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 27 | 15.16 | 454 | 186 | 0.19 / 118.12 | 2 | 2 |
2 | 7 | 2003.20 | 40 | 14.59 | 3123 | 1823 | 2.01 / 119.94 | 2 | 2 |
3 | 13 | 1594.92 | 29 | 14.64 | 2582 | 1096 | 3.10 / 121.04 | 2 | 3 |
4 | 13 | 833.20 | 29 | 14.87 | 1535 | 662 | 3.77 / 121.70 | 2 | 3 |
5 | 13 | 30.52 | 29 | 15.21 | 360 | 159 | 3.93 / 121.86 | 2 | 2 |
6 | 8 | -0.08 | 190 | 15.16 | 308 | 887 | 4.81 / 122.74 | 2 | 7 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 27 | 15.17 | 451 | 185 | 0.18 / 113.52 | 2 | 2 |
2 | 7 | 2004.08 | 40 | 14.60 | 3126 | 1826 | 2.01 / 115.35 | 2 | 2 |
3 | 13 | 1598.40 | 29 | 14.64 | 2589 | 1099 | 3.11 / 116.45 | 2 | 2 |
4 | 13 | 708.64 | 29 | 14.94 | 1356 | 588 | 3.70 / 117.04 | 2 | 3 |
5 | 8 | 0.08 | 190 | 15.18 | 310 | 894 | 4.59 / 117.93 | 2 | 6 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 27 | 15.17 | 446 | 183 | 0.18 / 108.91 | 2 | 2 |
2 | 7 | 2001.24 | 39 | 14.60 | 3116 | 1774 | 1.96 / 110.68 | 2 | 2 |
3 | 13 | 1591.44 | 29 | 14.65 | 2588 | 1100 | 3.06 / 111.78 | 2 | 3 |
4 | 13 | 837.40 | 29 | 14.87 | 1542 | 665 | 3.72 / 112.45 | 2 | 3 |
5 | 8 | 0.28 | 190 | 15.18 | 309 | 891 | 4.61 / 113.34 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 27 | 15.17 | 441 | 181 | 0.18 / 104.38 | 2 | 2 |
2 | 7 | 2001.96 | 39 | 14.61 | 3115 | 1775 | 1.96 / 106.15 | 2 | 2 |
3 | 13 | 1598.12 | 29 | 14.65 | 2589 | 1100 | 3.06 / 107.25 | 2 | 2 |
4 | 13 | 716.36 | 29 | 14.94 | 1361 | 590 | 3.65 / 107.84 | 2 | 2 |
5 | 8 | -0.28 | 190 | 15.18 | 307 | 885 | 4.53 / 108.73 | 2 | 5 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 26 | 15.17 | 444 | 175 | 0.18 / 99.72 | 2 | 2 |
2 | 7 | 2003.56 | 40 | 14.61 | 3127 | 1827 | 2.00 / 101.55 | 2 | 2 |
3 | 13 | 1726.60 | 28 | 14.62 | 2758 | 1129 | 3.13 / 102.68 | 2 | 2 |
4 | 13 | 809.88 | 28 | 14.90 | 1498 | 625 | 3.76 / 103.31 | 2 | 3 |
5 | 8 | -0.16 | 190 | 15.18 | 309 | 891 | 4.65 / 104.20 | 2 | 8 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 26 | 15.18 | 437 | 172 | 0.17 / 95.04 | 2 | 2 |
2 | 7 | 2003.56 | 39 | 14.62 | 3113 | 1775 | 1.95 / 96.81 | 2 | 2 |
3 | 13 | 1597.00 | 28 | 14.66 | 2585 | 1061 | 3.01 / 97.87 | 2 | 2 |
4 | 13 | 846.24 | 28 | 14.88 | 1548 | 645 | 3.65 / 98.52 | 2 | 4 |
5 | 13 | 20.32 | 28 | 15.23 | 336 | 143 | 3.80 / 98.66 | 2 | 2 |
6 | 8 | 0.04 | 190 | 15.18 | 307 | 885 | 4.68 / 99.55 | 2 | 8 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 26 | 15.17 | 444 | 175 | 0.18 / 90.52 | 2 | 2 |
2 | 7 | 2003.08 | 39 | 14.62 | 3107 | 1772 | 1.95 / 92.29 | 2 | 2 |
3 | 13 | 1588.96 | 28 | 14.67 | 2565 | 1054 | 3.00 / 93.35 | 2 | 2 |
4 | 13 | 837.96 | 28 | 14.89 | 1535 | 640 | 3.64 / 93.99 | 2 | 2 |
5 | 8 | 0.04 | 190 | 15.20 | 304 | 878 | 4.52 / 94.87 | 2 | 6 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 26 | 15.19 | 441 | 174 | 0.17 / 85.81 | 2 | 2 |
2 | 7 | 2004.32 | 39 | 14.62 | 3115 | 1776 | 1.95 / 87.59 | 2 | 2 |
3 | 13 | 1602.12 | 28 | 14.66 | 2594 | 1065 | 3.02 / 88.65 | 2 | 2 |
4 | 13 | 846.60 | 28 | 14.89 | 1550 | 646 | 3.66 / 89.30 | 2 | 2 |
5 | 13 | 37.36 | 28 | 15.22 | 371 | 158 | 3.82 / 89.45 | 2 | 2 |
6 | 8 | -0.24 | 190 | 15.18 | 310 | 894 | 4.71 / 90.35 | 2 | 12 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 26 | 15.19 | 437 | 173 | 0.17 / 81.36 | 2 | 2 |
2 | 7 | 2002.52 | 38 | 14.64 | 3121 | 1736 | 1.91 / 83.09 | 2 | 2 |
3 | 13 | 1602.88 | 28 | 14.67 | 2590 | 1064 | 2.97 / 84.16 | 2 | 2 |
4 | 13 | 742.24 | 28 | 14.95 | 1402 | 587 | 3.56 / 84.75 | 2 | 2 |
5 | 8 | 0.00 | 190 | 15.20 | 308 | 890 | 4.45 / 85.63 | 2 | 5 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 26 | 15.20 | 430 | 170 | 0.17 / 77.09 | 2 | 2 |
2 | 7 | 2001.28 | 37 | 14.64 | 3114 | 1687 | 1.86 / 78.78 | 2 | 2 |
3 | 13 | 1490.80 | 28 | 14.71 | 2431 | 1001 | 2.86 / 79.78 | 2 | 2 |
4 | 13 | 665.44 | 28 | 14.99 | 1277 | 536 | 3.39 / 80.31 | 2 | 2 |
5 | 8 | 0.00 | 190 | 15.20 | 302 | 872 | 4.27 / 81.19 | 2 | 4 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 26 | 15.20 | 455 | 180 | 0.18 / 72.81 | 2 | 2 |
2 | 7 | 2003.16 | 37 | 14.66 | 3101 | 1682 | 1.86 / 74.49 | 2 | 2 |
3 | 13 | 1508.60 | 28 | 14.71 | 2454 | 1011 | 2.87 / 75.50 | 2 | 2 |
4 | 13 | 683.08 | 28 | 14.98 | 1305 | 547 | 3.42 / 76.05 | 2 | 2 |
5 | 8 | -0.20 | 190 | 15.21 | 301 | 870 | 4.29 / 76.92 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 26 | 15.21 | 435 | 172 | 0.17 / 68.55 | 2 | 2 |
2 | 7 | 2003.68 | 37 | 14.65 | 3102 | 1681 | 1.85 / 70.23 | 2 | 2 |
3 | 13 | 1485.08 | 28 | 14.72 | 2425 | 999 | 2.85 / 71.23 | 2 | 2 |
4 | 13 | 656.04 | 28 | 15.00 | 1268 | 533 | 3.39 / 71.76 | 2 | 2 |
5 | 8 | 0.16 | 190 | 15.21 | 301 | 870 | 4.26 / 72.63 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 26 | 15.21 | 423 | 167 | 0.17 / 64.32 | 2 | 2 |
2 | 7 | 2001.92 | 37 | 14.66 | 3099 | 1681 | 1.85 / 66.00 | 2 | 2 |
3 | 13 | 1486.32 | 28 | 14.72 | 2412 | 994 | 2.84 / 66.99 | 2 | 2 |
4 | 13 | 655.88 | 28 | 15.01 | 1260 | 530 | 3.37 / 67.52 | 2 | 2 |
5 | 8 | -0.08 | 190 | 15.22 | 295 | 853 | 4.23 / 68.37 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 26 | 15.20 | 437 | 173 | 0.17 / 60.07 | 2 | 2 |
2 | 7 | 2003.00 | 37 | 14.66 | 3107 | 1685 | 1.86 / 61.76 | 2 | 2 |
3 | 13 | 1489.76 | 28 | 14.73 | 2423 | 999 | 2.86 / 62.76 | 2 | 2 |
4 | 13 | 659.72 | 28 | 15.01 | 1272 | 535 | 3.39 / 63.29 | 2 | 2 |
5 | 8 | 0.00 | 190 | 15.22 | 297 | 859 | 4.25 / 64.15 | 2 | 8 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 26 | 15.20 | 435 | 172 | 0.17 / 55.82 | 2 | 2 |
2 | 7 | 2002.68 | 37 | 14.67 | 3110 | 1688 | 1.86 / 57.51 | 2 | 2 |
3 | 13 | 1486.24 | 28 | 14.73 | 2422 | 999 | 2.86 / 58.51 | 2 | 2 |
4 | 13 | 645.92 | 28 | 15.01 | 1246 | 524 | 3.38 / 59.03 | 2 | 2 |
5 | 8 | -0.04 | 190 | 15.22 | 299 | 865 | 4.25 / 59.90 | 2 | 6 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 26 | 15.21 | 447 | 177 | 0.18 / 51.34 | 2 | 2 |
2 | 7 | 2002.28 | 37 | 14.68 | 3095 | 1681 | 1.86 / 53.02 | 2 | 2 |
3 | 13 | 1604.16 | 28 | 14.71 | 2578 | 1062 | 2.92 / 54.08 | 2 | 2 |
4 | 13 | 739.80 | 28 | 14.97 | 1382 | 579 | 3.50 / 54.66 | 2 | 2 |
5 | 13 | 19.24 | 28 | 15.26 | 328 | 140 | 3.64 / 54.80 | 2 | 2 |
6 | 8 | -0.16 | 190 | 15.21 | 295 | 853 | 4.49 / 55.65 | 2 | 5 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 26 | 15.21 | 438 | 173 | 0.17 / 47.08 | 2 | 2 |
2 | 7 | 2004.04 | 37 | 14.68 | 3107 | 1688 | 1.86 / 48.77 | 2 | 2 |
3 | 13 | 1487.72 | 28 | 14.73 | 2414 | 996 | 2.86 / 49.76 | 2 | 2 |
4 | 13 | 649.84 | 28 | 15.01 | 1258 | 529 | 3.39 / 50.29 | 2 | 2 |
5 | 8 | -0.08 | 190 | 15.22 | 300 | 868 | 4.25 / 51.16 | 2 | 6 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 26 | 15.21 | 434 | 172 | 0.17 / 42.78 | 2 | 2 |
2 | 7 | 2000.76 | 38 | 14.69 | 3097 | 1729 | 1.90 / 44.51 | 2 | 2 |
3 | 13 | 1482.84 | 28 | 14.74 | 2420 | 999 | 2.90 / 45.51 | 2 | 2 |
4 | 13 | 654.08 | 28 | 15.01 | 1261 | 530 | 3.43 / 46.04 | 2 | 2 |
5 | 8 | 0.04 | 190 | 15.22 | 300 | 868 | 4.30 / 46.91 | 2 | 8 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 26 | 15.20 | 459 | 181 | 0.18 / 38.59 | 2 | 2 |
2 | 7 | 2003.76 | 37 | 14.69 | 3107 | 1689 | 1.87 / 40.28 | 2 | 2 |
3 | 13 | 1498.96 | 28 | 14.73 | 2439 | 1006 | 2.88 / 41.29 | 2 | 2 |
4 | 13 | 549.64 | 28 | 15.07 | 1110 | 468 | 3.34 / 41.75 | 2 | 2 |
5 | 8 | -0.08 | 190 | 15.23 | 296 | 857 | 4.20 / 42.61 | 2 | 7 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 26 | 15.20 | 454 | 179 | 0.18 / 34.23 | 2 | 2 |
2 | 7 | 2002.40 | 38 | 14.69 | 3110 | 1736 | 1.92 / 35.96 | 2 | 2 |
3 | 13 | 1481.48 | 25 | 14.76 | 2421 | 893 | 2.81 / 36.86 | 2 | 2 |
4 | 13 | 790.36 | 25 | 14.96 | 1464 | 548 | 3.36 / 37.40 | 2 | 2 |
5 | 13 | 16.24 | 25 | 15.27 | 333 | 127 | 3.48 / 37.53 | 2 | 2 |
6 | 8 | -0.16 | 190 | 15.21 | 304 | 879 | 4.36 / 38.41 | 2 | 5 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 26 | 15.21 | 453 | 179 | 0.18 / 29.76 | 2 | 2 |
2 | 7 | 2001.00 | 43 | 14.67 | 3108 | 1961 | 2.14 / 31.72 | 2 | 2 |
3 | 13 | 1325.80 | 22 | 14.80 | 2198 | 716 | 2.86 / 32.44 | 2 | 2 |
4 | 13 | 653.20 | 22 | 15.03 | 1261 | 417 | 3.27 / 32.85 | 2 | 2 |
5 | 13 | 18.28 | 22 | 15.27 | 330 | 111 | 3.38 / 32.96 | 2 | 2 |
6 | 8 | -0.04 | 240 | 15.21 | 297 | 1084 | 4.47 / 34.05 | 2 | 18 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 25 | 15.19 | 457 | 174 | 0.17 / 25.37 | 2 | 2 |
2 | 7 | 2001.08 | 43 | 14.67 | 3101 | 1956 | 2.13 / 27.32 | 2 | 2 |
3 | 13 | 1332.60 | 20 | 14.81 | 2211 | 655 | 2.78 / 27.98 | 2 | 2 |
4 | 13 | 674.80 | 20 | 15.03 | 1300 | 391 | 3.18 / 28.37 | 2 | 2 |
5 | 13 | 27.16 | 20 | 15.27 | 350 | 107 | 3.28 / 28.48 | 2 | 2 |
6 | 8 | 0.16 | 240 | 15.21 | 302 | 1102 | 4.38 / 29.58 | 2 | 17 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 25 | 15.20 | 453 | 172 | 0.17 / 20.79 | 2 | 2 |
2 | 3 | 1037.60 | 1 | 15.28 | 1845 | 28 | 0.20 / 20.82 | 2 | 2 |
3 | 7 | 2001.56 | 49 | 14.65 | 3100 | 2225 | 2.43 / 23.05 | 2 | 2 |
4 | 13 | 1173.56 | 25 | 14.84 | 1998 | 741 | 3.17 / 23.79 | 2 | 2 |
5 | 13 | 345.12 | 25 | 15.16 | 818 | 310 | 3.48 / 24.10 | 2 | 2 |
6 | 8 | -0.08 | 240 | 15.21 | 301 | 1099 | 4.58 / 25.20 | 2 | 19 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 24 | 15.21 | 464 | 169 | 0.17 / 16.32 | 2 | 2 |
2 | 7 | 1990.96 | 50 | 14.65 | 3082 | 2258 | 2.43 / 18.57 | 2 | 2 |
3 | 13 | 1152.16 | 25 | 14.85 | 1971 | 732 | 3.16 / 19.30 | 2 | 2 |
4 | 13 | 197.08 | 25 | 15.22 | 594 | 226 | 3.38 / 19.53 | 2 | 2 |
5 | 8 | -0.04 | 240 | 15.22 | 298 | 1089 | 4.47 / 20.62 | 2 | 11 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 24 | 15.20 | 453 | 165 | 0.17 / 12.50 | 2 | 2 |
2 | 7 | 1512.56 | 49 | 14.88 | 2434 | 1775 | 1.94 / 14.27 | 2 | 2 |
3 | 13 | 998.76 | 25 | 14.96 | 1756 | 657 | 2.60 / 14.93 | 2 | 2 |
4 | 13 | 36.80 | 25 | 15.30 | 355 | 136 | 2.73 / 15.06 | 2 | 2 |
5 | 8 | -0.04 | 240 | 15.24 | 296 | 1083 | 3.82 / 16.15 | 2 | 18 |
Average= | 3.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 24 | 15.21 | 460 | 168 | 0.17 / 8.70 | 2 | 2 |
2 | 7 | 1508.64 | 50 | 14.88 | 2440 | 1815 | 1.98 / 10.52 | 2 | 2 |
3 | 13 | 870.92 | 25 | 14.99 | 1575 | 590 | 2.57 / 11.11 | 2 | 2 |
4 | 13 | 16.60 | 25 | 15.30 | 330 | 126 | 2.70 / 11.23 | 2 | 2 |
5 | 8 | 0.08 | 240 | 15.23 | 300 | 1097 | 3.80 / 12.33 | 2 | 18 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 24 | 15.20 | 453 | 165 | 0.17 / 5.02 | 2 | 2 |
2 | 7 | 1513.28 | 49 | 14.87 | 2441 | 1779 | 1.94 / 6.80 | 2 | 2 |
3 | 13 | 983.44 | 25 | 14.95 | 1737 | 649 | 2.59 / 7.44 | 2 | 2 |
4 | 8 | 0.16 | 240 | 15.24 | 298 | 1090 | 3.68 / 8.53 | 2 | 9 |
Average= | 2.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 24 | 15.31 | 433 | 159 | 0.16 / 1.88 | 2 | 2 |
2 | 7 | 987.24 | 74 | 14.98 | 1708 | 1893 | 2.05 / 3.77 | 2 | 2 |
3 | 8 | -0.04 | 240 | 15.24 | 296 | 1083 | 3.14 / 4.85 | 2 | 15 |
Average= | 2.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 24 | 15.53 | 453 | 169 | 0.17 / 0.17 | 2 | 2 |
2 | 7 | 115.84 | 74 | 15.48 | 451 | 517 | 0.69 / 0.69 | 2 | 2 |
3 | 8 | 0.12 | 240 | 15.40 | 279 | 1031 | 1.72 / 1.72 | 2 | 22 |
Average= | 1.72 (KJ/cycle) |