SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 27 | 14.63 | 477 | 188 | 0.19 / 8.93 | 2 | 2 |
2 | 7 | 1514.60 | 74 | 13.05 | 2529 | 2442 | 2.63 / 11.37 | 2 | 2 |
3 | 13 | 781.60 | 20 | 13.95 | 1487 | 415 | 3.05 / 11.78 | 2 | 2 |
4 | 13 | 16.92 | 20 | 14.78 | 343 | 101 | 3.15 / 11.89 | 2 | 2 |
5 | 14 | -0.04 | 240 | 14.23 | 370 | 1264 | 4.41 / 13.15 | 2 | 22 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 24 | 14.63 | 469 | 165 | 0.16 / 4.65 | 2 | 2 |
2 | 10 | 1015.04 | 3 | 14.40 | 1863 | 80 | 0.25 / 4.73 | 2 | 2 |
3 | 7 | 1501.76 | 74 | 12.92 | 2519 | 2408 | 2.65 / 7.14 | 2 | 2 |
4 | 13 | 769.60 | 20 | 13.90 | 1461 | 406 | 3.06 / 7.54 | 2 | 2 |
5 | 13 | 140.48 | 20 | 14.56 | 527 | 153 | 3.21 / 7.70 | 2 | 2 |
6 | 14 | 0.08 | 241 | 14.33 | 302 | 1043 | 4.26 / 8.74 | 2 | 22 |
Average= | 2.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 27 | 14.54 | 461 | 181 | 0.18 / 1.72 | 2 | 2 |
2 | 7 | 998.20 | 74 | 13.15 | 1788 | 1740 | 1.92 / 3.46 | 2 | 2 |
3 | 14 | -0.04 | 240 | 14.30 | 297 | 1019 | 2.94 / 4.48 | 2 | 22 |
Average= | 2.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 76.36 | 26 | 14.32 | 408 | 152 | 0.15 / 0.15 | 2 | 2 |
2 | 7 | 82.56 | 75 | 14.16 | 409 | 434 | 0.59 / 0.59 | 2 | 2 |
3 | 14 | -0.00 | 241 | 14.28 | 278 | 957 | 1.54 / 1.54 | 2 | 31 |
Average= | 1.54 (KJ/cycle) |