SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 25 | 15.00 | 507 | 190 | 0.19 / 450.29 | 2 | 3 |
2 | 7 | 1904.36 | 38 | 14.58 | 2985 | 1654 | 1.84 / 451.94 | 2 | 4 |
3 | 13 | 1329.72 | 18 | 14.72 | 2254 | 597 | 2.44 / 452.54 | 2 | 5 |
4 | 13 | 776.28 | 18 | 14.85 | 1504 | 402 | 2.84 / 452.94 | 2 | 5 |
5 | 13 | 337.04 | 18 | 14.99 | 863 | 233 | 3.08 / 453.18 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.07 | 323 | 803 | 3.88 / 453.98 | 2 | 10 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 25 | 15.01 | 490 | 184 | 0.18 / 446.43 | 2 | 2 |
2 | 7 | 1905.72 | 38 | 14.58 | 2978 | 1650 | 1.83 / 448.08 | 2 | 3 |
3 | 13 | 1340.40 | 18 | 14.70 | 2266 | 600 | 2.43 / 448.68 | 2 | 3 |
4 | 13 | 734.84 | 18 | 14.84 | 1434 | 383 | 2.82 / 449.06 | 2 | 4 |
5 | 13 | 304.24 | 18 | 15.01 | 816 | 220 | 3.04 / 449.28 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.06 | 328 | 815 | 3.85 / 450.10 | 2 | 10 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 25 | 15.02 | 483 | 181 | 0.18 / 442.54 | 2 | 2 |
2 | 7 | 1906.20 | 38 | 14.58 | 2969 | 1645 | 1.83 / 444.18 | 2 | 4 |
3 | 13 | 1294.24 | 18 | 14.73 | 2199 | 583 | 2.41 / 444.77 | 2 | 4 |
4 | 13 | 747.72 | 18 | 14.85 | 1458 | 390 | 2.80 / 445.16 | 2 | 5 |
5 | 13 | 259.84 | 18 | 15.03 | 738 | 200 | 3.00 / 445.36 | 2 | 4 |
6 | 13 | 42.00 | 18 | 15.08 | 391 | 106 | 3.10 / 445.46 | 2 | 4 |
7 | 8 | 0.00 | 165 | 15.05 | 316 | 785 | 3.89 / 446.25 | 2 | 7 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 25 | 15.02 | 501 | 188 | 0.19 / 438.63 | 2 | 3 |
2 | 7 | 1903.36 | 38 | 14.59 | 2976 | 1650 | 1.84 / 440.28 | 2 | 4 |
3 | 13 | 1234.56 | 18 | 14.74 | 2141 | 568 | 2.41 / 440.85 | 2 | 4 |
4 | 13 | 800.08 | 18 | 14.84 | 1534 | 410 | 2.82 / 441.26 | 2 | 4 |
5 | 13 | 251.20 | 18 | 15.04 | 731 | 198 | 3.01 / 441.45 | 2 | 4 |
6 | 13 | 31.92 | 18 | 15.11 | 385 | 105 | 3.12 / 441.56 | 2 | 4 |
7 | 8 | -0.08 | 165 | 15.06 | 322 | 800 | 3.92 / 442.36 | 2 | 11 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 25 | 15.02 | 482 | 181 | 0.18 / 434.70 | 2 | 2 |
2 | 7 | 1902.00 | 38 | 14.60 | 2976 | 1651 | 1.83 / 436.35 | 2 | 3 |
3 | 13 | 1240.64 | 18 | 14.73 | 2144 | 568 | 2.40 / 436.92 | 2 | 4 |
4 | 13 | 800.96 | 18 | 14.84 | 1529 | 408 | 2.81 / 437.33 | 2 | 4 |
5 | 13 | 294.56 | 18 | 15.00 | 794 | 214 | 3.02 / 437.54 | 2 | 4 |
6 | 13 | 28.24 | 18 | 15.08 | 374 | 102 | 3.12 / 437.65 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.04 | 320 | 794 | 3.92 / 438.44 | 2 | 7 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 25 | 15.03 | 475 | 178 | 0.18 / 430.77 | 2 | 3 |
2 | 7 | 1904.44 | 38 | 14.60 | 2979 | 1653 | 1.83 / 432.42 | 2 | 3 |
3 | 13 | 1302.40 | 18 | 14.74 | 2215 | 588 | 2.42 / 433.01 | 2 | 4 |
4 | 13 | 813.76 | 18 | 14.83 | 1555 | 415 | 2.83 / 433.43 | 2 | 5 |
5 | 13 | 268.72 | 18 | 15.03 | 752 | 203 | 3.04 / 433.63 | 2 | 4 |
6 | 13 | 22.72 | 18 | 15.10 | 363 | 99 | 3.14 / 433.73 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.05 | 319 | 792 | 3.93 / 434.52 | 2 | 9 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 25 | 15.02 | 489 | 184 | 0.18 / 426.85 | 2 | 2 |
2 | 7 | 1901.60 | 38 | 14.60 | 2972 | 1649 | 1.83 / 428.50 | 2 | 3 |
3 | 13 | 1280.64 | 18 | 14.75 | 2187 | 581 | 2.41 / 429.08 | 2 | 3 |
4 | 13 | 755.68 | 18 | 14.87 | 1466 | 392 | 2.81 / 429.47 | 2 | 4 |
5 | 13 | 326.40 | 18 | 15.00 | 835 | 225 | 3.03 / 429.70 | 2 | 4 |
6 | 13 | 36.00 | 18 | 15.10 | 385 | 105 | 3.14 / 429.80 | 2 | 4 |
7 | 8 | 0.00 | 165 | 15.06 | 318 | 790 | 3.93 / 430.59 | 2 | 11 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 25 | 15.03 | 492 | 185 | 0.18 / 422.96 | 2 | 2 |
2 | 7 | 1905.08 | 38 | 14.60 | 2971 | 1648 | 1.83 / 424.60 | 2 | 3 |
3 | 13 | 1230.96 | 18 | 14.75 | 2124 | 564 | 2.40 / 425.17 | 2 | 3 |
4 | 13 | 798.72 | 18 | 14.84 | 1548 | 414 | 2.81 / 425.58 | 2 | 4 |
5 | 13 | 242.20 | 18 | 15.04 | 715 | 194 | 3.00 / 425.78 | 2 | 4 |
6 | 13 | 34.32 | 18 | 15.11 | 382 | 104 | 3.11 / 425.88 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.06 | 317 | 788 | 3.90 / 426.67 | 2 | 10 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 25 | 15.02 | 480 | 180 | 0.18 / 419.04 | 2 | 2 |
2 | 7 | 1903.04 | 38 | 14.58 | 2966 | 1643 | 1.82 / 420.69 | 2 | 3 |
3 | 13 | 1288.76 | 18 | 14.71 | 2208 | 585 | 2.41 / 421.27 | 2 | 4 |
4 | 13 | 829.96 | 18 | 14.81 | 1574 | 420 | 2.83 / 421.69 | 2 | 4 |
5 | 13 | 233.48 | 18 | 15.04 | 699 | 189 | 3.02 / 421.88 | 2 | 4 |
6 | 13 | 27.24 | 18 | 15.10 | 369 | 100 | 3.12 / 421.98 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.05 | 318 | 790 | 3.91 / 422.77 | 2 | 11 |
Average= | 5.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.92 | 25 | 15.01 | 502 | 188 | 0.19 / 415.09 | 2 | 2 |
2 | 7 | 1903.16 | 38 | 14.60 | 2978 | 1652 | 1.84 / 416.74 | 2 | 3 |
3 | 13 | 1288.24 | 18 | 14.72 | 2207 | 585 | 2.43 / 417.32 | 2 | 3 |
4 | 13 | 789.84 | 18 | 14.84 | 1526 | 408 | 2.83 / 417.73 | 2 | 4 |
5 | 13 | 336.08 | 18 | 14.99 | 859 | 232 | 3.06 / 417.96 | 2 | 5 |
6 | 13 | 23.12 | 18 | 15.11 | 370 | 101 | 3.17 / 418.06 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.07 | 322 | 801 | 3.97 / 418.86 | 2 | 11 |
Average= | 5.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 25 | 15.03 | 488 | 183 | 0.18 / 411.20 | 2 | 2 |
2 | 7 | 1902.20 | 38 | 14.58 | 2977 | 1649 | 1.83 / 412.84 | 2 | 3 |
3 | 13 | 1255.76 | 18 | 14.72 | 2163 | 573 | 2.41 / 413.42 | 2 | 4 |
4 | 13 | 773.92 | 18 | 14.85 | 1500 | 401 | 2.81 / 413.82 | 2 | 4 |
5 | 13 | 228.36 | 18 | 15.03 | 691 | 187 | 2.99 / 414.01 | 2 | 4 |
6 | 13 | 24.08 | 18 | 15.10 | 367 | 100 | 3.09 / 414.11 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.06 | 319 | 793 | 3.89 / 414.90 | 2 | 10 |
Average= | 5.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 25 | 15.03 | 502 | 189 | 0.19 / 407.28 | 2 | 2 |
2 | 7 | 1902.68 | 38 | 14.59 | 2970 | 1647 | 1.84 / 408.92 | 2 | 3 |
3 | 13 | 1254.32 | 18 | 14.74 | 2153 | 571 | 2.41 / 409.49 | 2 | 4 |
4 | 13 | 807.20 | 18 | 14.85 | 1547 | 414 | 2.82 / 409.91 | 2 | 4 |
5 | 13 | 256.56 | 18 | 15.03 | 742 | 201 | 3.02 / 410.11 | 2 | 4 |
6 | 13 | 22.08 | 18 | 15.11 | 368 | 100 | 3.12 / 410.21 | 2 | 4 |
7 | 8 | -0.12 | 165 | 15.06 | 323 | 803 | 3.92 / 411.01 | 2 | 11 |
Average= | 5.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 25 | 15.03 | 491 | 184 | 0.18 / 403.29 | 2 | 2 |
2 | 7 | 1903.80 | 38 | 14.60 | 2978 | 1652 | 1.84 / 404.95 | 2 | 3 |
3 | 13 | 1347.88 | 18 | 14.72 | 2278 | 604 | 2.44 / 405.55 | 2 | 3 |
4 | 13 | 793.68 | 18 | 14.84 | 1510 | 403 | 2.84 / 405.95 | 2 | 4 |
5 | 13 | 343.40 | 18 | 14.99 | 873 | 236 | 3.08 / 406.19 | 2 | 4 |
6 | 13 | 29.20 | 18 | 15.12 | 374 | 102 | 3.18 / 406.29 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.08 | 321 | 799 | 3.98 / 407.09 | 2 | 9 |
Average= | 5.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 25 | 15.04 | 486 | 183 | 0.18 / 399.40 | 2 | 2 |
2 | 7 | 1904.24 | 38 | 14.61 | 2975 | 1652 | 1.83 / 401.05 | 2 | 3 |
3 | 13 | 1289.56 | 18 | 14.73 | 2192 | 581 | 2.42 / 401.64 | 2 | 4 |
4 | 13 | 742.72 | 18 | 14.86 | 1447 | 387 | 2.80 / 402.02 | 2 | 4 |
5 | 13 | 263.28 | 18 | 15.03 | 743 | 201 | 3.00 / 402.22 | 2 | 4 |
6 | 13 | 19.84 | 18 | 15.10 | 356 | 97 | 3.10 / 402.32 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.07 | 317 | 788 | 3.89 / 403.11 | 2 | 8 |
Average= | 5.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 25 | 15.04 | 485 | 182 | 0.18 / 395.47 | 2 | 2 |
2 | 7 | 1904.00 | 38 | 14.61 | 2971 | 1649 | 1.83 / 397.12 | 2 | 3 |
3 | 13 | 1298.92 | 18 | 14.75 | 2201 | 584 | 2.42 / 397.71 | 2 | 3 |
4 | 13 | 802.92 | 18 | 14.85 | 1524 | 407 | 2.82 / 398.12 | 2 | 4 |
5 | 13 | 254.44 | 18 | 15.04 | 736 | 199 | 3.02 / 398.31 | 2 | 4 |
6 | 13 | 20.64 | 18 | 15.11 | 368 | 100 | 3.12 / 398.41 | 2 | 4 |
7 | 8 | -0.08 | 165 | 15.07 | 324 | 806 | 3.93 / 399.22 | 2 | 8 |
Average= | 5.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 25 | 15.04 | 487 | 183 | 0.18 / 391.58 | 2 | 2 |
2 | 7 | 1903.12 | 38 | 14.62 | 2977 | 1654 | 1.84 / 393.24 | 2 | 4 |
3 | 13 | 1282.40 | 18 | 14.76 | 2180 | 579 | 2.42 / 393.82 | 2 | 4 |
4 | 13 | 752.48 | 18 | 14.88 | 1456 | 390 | 2.81 / 394.21 | 2 | 4 |
5 | 13 | 274.80 | 18 | 15.04 | 757 | 205 | 3.01 / 394.41 | 2 | 4 |
6 | 13 | 24.20 | 18 | 15.12 | 360 | 98 | 3.11 / 394.51 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.09 | 314 | 782 | 3.89 / 395.29 | 2 | 13 |
Average= | 5.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 25 | 15.05 | 488 | 184 | 0.18 / 387.70 | 2 | 3 |
2 | 7 | 1902.24 | 38 | 14.61 | 2973 | 1651 | 1.83 / 389.36 | 2 | 3 |
3 | 13 | 1194.96 | 18 | 14.78 | 2058 | 548 | 2.38 / 389.90 | 2 | 5 |
4 | 13 | 859.44 | 18 | 14.84 | 1612 | 431 | 2.81 / 390.33 | 2 | 4 |
5 | 13 | 241.80 | 18 | 15.06 | 709 | 192 | 3.00 / 390.53 | 2 | 4 |
6 | 13 | 13.68 | 18 | 15.13 | 345 | 94 | 3.10 / 390.62 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.08 | 314 | 781 | 3.88 / 391.40 | 2 | 9 |
Average= | 5.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 25 | 15.04 | 489 | 184 | 0.18 / 383.86 | 2 | 2 |
2 | 7 | 1905.44 | 39 | 14.61 | 2974 | 1695 | 1.88 / 385.55 | 2 | 4 |
3 | 13 | 1232.84 | 18 | 14.76 | 2115 | 562 | 2.44 / 386.11 | 2 | 4 |
4 | 13 | 765.12 | 18 | 14.87 | 1480 | 396 | 2.84 / 386.51 | 2 | 4 |
5 | 13 | 310.04 | 18 | 15.03 | 827 | 224 | 3.06 / 386.73 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.09 | 317 | 789 | 3.85 / 387.52 | 2 | 9 |
Average= | 5.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 25 | 15.05 | 471 | 177 | 0.18 / 379.90 | 2 | 2 |
2 | 7 | 1902.72 | 39 | 14.61 | 2988 | 1703 | 1.88 / 381.60 | 2 | 3 |
3 | 13 | 1215.00 | 18 | 14.78 | 2078 | 553 | 2.43 / 382.16 | 2 | 3 |
4 | 13 | 729.48 | 18 | 14.89 | 1443 | 387 | 2.82 / 382.54 | 2 | 4 |
5 | 13 | 341.36 | 18 | 15.02 | 870 | 235 | 3.05 / 382.78 | 2 | 4 |
6 | 13 | 19.60 | 18 | 15.12 | 356 | 97 | 3.15 / 382.88 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.08 | 320 | 796 | 3.95 / 383.67 | 2 | 10 |
Average= | 5.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 25 | 15.05 | 490 | 184 | 0.18 / 376.14 | 2 | 2 |
2 | 7 | 1901.44 | 38 | 14.60 | 2973 | 1649 | 1.83 / 377.79 | 2 | 3 |
3 | 13 | 1236.48 | 18 | 14.75 | 2134 | 567 | 2.40 / 378.36 | 2 | 4 |
4 | 13 | 752.44 | 18 | 14.87 | 1457 | 390 | 2.79 / 378.75 | 2 | 4 |
5 | 13 | 268.52 | 18 | 15.05 | 743 | 201 | 2.99 / 378.95 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.09 | 312 | 777 | 3.77 / 379.72 | 2 | 9 |
Average= | 5.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 25 | 15.04 | 487 | 183 | 0.18 / 372.32 | 2 | 2 |
2 | 7 | 1904.08 | 38 | 14.61 | 2973 | 1651 | 1.83 / 373.97 | 2 | 3 |
3 | 13 | 1322.16 | 18 | 14.74 | 2250 | 597 | 2.43 / 374.57 | 2 | 4 |
4 | 13 | 761.68 | 18 | 14.87 | 1481 | 396 | 2.83 / 374.96 | 2 | 4 |
5 | 13 | 272.28 | 18 | 15.04 | 753 | 204 | 3.03 / 375.17 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.09 | 316 | 787 | 3.82 / 375.96 | 2 | 10 |
Average= | 5.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 25 | 15.05 | 487 | 183 | 0.18 / 368.51 | 2 | 3 |
2 | 7 | 1901.68 | 38 | 14.61 | 2972 | 1650 | 1.83 / 370.16 | 2 | 3 |
3 | 13 | 1288.60 | 18 | 14.75 | 2194 | 583 | 2.42 / 370.74 | 2 | 3 |
4 | 13 | 758.92 | 18 | 14.88 | 1478 | 396 | 2.81 / 371.13 | 2 | 4 |
5 | 13 | 281.44 | 18 | 15.04 | 770 | 208 | 3.02 / 371.34 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.09 | 319 | 794 | 3.81 / 372.14 | 2 | 9 |
Average= | 5.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 25 | 15.04 | 494 | 186 | 0.19 / 364.73 | 2 | 2 |
2 | 7 | 1902.40 | 38 | 14.60 | 2975 | 1651 | 1.84 / 366.38 | 2 | 3 |
3 | 13 | 1231.52 | 18 | 14.77 | 2117 | 563 | 2.40 / 366.94 | 2 | 5 |
4 | 13 | 747.04 | 18 | 14.89 | 1449 | 388 | 2.79 / 367.33 | 2 | 4 |
5 | 13 | 265.52 | 18 | 15.05 | 740 | 200 | 2.99 / 367.53 | 2 | 4 |
6 | 8 | -0.08 | 165 | 15.10 | 319 | 795 | 3.78 / 368.32 | 2 | 9 |
Average= | 5.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 25 | 15.05 | 491 | 185 | 0.18 / 360.91 | 2 | 3 |
2 | 7 | 1905.52 | 38 | 14.60 | 2975 | 1651 | 1.84 / 362.56 | 2 | 3 |
3 | 13 | 1292.72 | 18 | 14.75 | 2193 | 582 | 2.42 / 363.15 | 2 | 4 |
4 | 13 | 753.36 | 18 | 14.88 | 1463 | 392 | 2.81 / 363.54 | 2 | 4 |
5 | 13 | 234.48 | 18 | 15.07 | 706 | 192 | 3.00 / 363.73 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.09 | 326 | 812 | 3.81 / 364.54 | 2 | 10 |
Average= | 5.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 25 | 15.06 | 481 | 181 | 0.18 / 357.10 | 2 | 2 |
2 | 7 | 1905.40 | 38 | 14.60 | 2977 | 1652 | 1.83 / 358.75 | 2 | 3 |
3 | 13 | 1290.96 | 18 | 14.76 | 2193 | 583 | 2.42 / 359.33 | 2 | 4 |
4 | 13 | 746.08 | 18 | 14.90 | 1462 | 392 | 2.81 / 359.73 | 2 | 4 |
5 | 13 | 269.48 | 18 | 15.06 | 755 | 205 | 3.01 / 359.93 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.10 | 320 | 797 | 3.81 / 360.73 | 2 | 9 |
Average= | 5.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 25 | 15.04 | 491 | 185 | 0.18 / 353.25 | 2 | 2 |
2 | 7 | 1901.52 | 38 | 14.60 | 2971 | 1648 | 1.83 / 354.90 | 2 | 4 |
3 | 13 | 1378.00 | 18 | 14.71 | 2323 | 615 | 2.45 / 355.51 | 2 | 4 |
4 | 13 | 748.84 | 18 | 14.90 | 1457 | 391 | 2.84 / 355.91 | 2 | 4 |
5 | 13 | 315.52 | 18 | 15.05 | 823 | 223 | 3.06 / 356.13 | 2 | 4 |
6 | 8 | 0.24 | 165 | 15.11 | 317 | 790 | 3.85 / 356.92 | 2 | 9 |
Average= | 5.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 25 | 15.07 | 489 | 184 | 0.18 / 349.09 | 2 | 3 |
2 | 7 | 1902.88 | 38 | 14.60 | 2978 | 1652 | 1.84 / 350.74 | 2 | 4 |
3 | 13 | 1249.56 | 18 | 14.74 | 2145 | 569 | 2.41 / 351.31 | 2 | 4 |
4 | 13 | 774.08 | 18 | 14.87 | 1489 | 399 | 2.80 / 351.71 | 2 | 4 |
5 | 13 | 283.72 | 18 | 15.04 | 771 | 209 | 3.01 / 351.92 | 2 | 4 |
6 | 8 | -0.20 | 165 | 15.10 | 319 | 795 | 3.81 / 352.71 | 2 | 6 |
7 | 14 | -0.20 | 75 | 15.06 | 315 | 356 | 4.16 / 353.07 | 2 | 14 |
Average= | 5.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 25 | 15.05 | 497 | 187 | 0.19 / 345.22 | 2 | 2 |
2 | 7 | 1907.60 | 38 | 14.59 | 2985 | 1655 | 1.84 / 346.87 | 2 | 3 |
3 | 13 | 1291.20 | 18 | 14.74 | 2195 | 582 | 2.42 / 347.45 | 2 | 4 |
4 | 13 | 845.72 | 18 | 14.83 | 1595 | 426 | 2.85 / 347.88 | 2 | 4 |
5 | 13 | 343.36 | 18 | 15.02 | 865 | 234 | 3.08 / 348.11 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.10 | 317 | 790 | 3.87 / 348.90 | 2 | 8 |
Average= | 6.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 25 | 15.06 | 493 | 186 | 0.19 / 341.35 | 2 | 3 |
2 | 7 | 1903.72 | 38 | 14.60 | 2990 | 1659 | 1.84 / 343.01 | 2 | 3 |
3 | 13 | 1304.40 | 18 | 14.74 | 2225 | 590 | 2.43 / 343.60 | 2 | 3 |
4 | 13 | 809.56 | 18 | 14.87 | 1550 | 415 | 2.85 / 344.02 | 2 | 4 |
5 | 13 | 309.00 | 18 | 15.04 | 811 | 220 | 3.07 / 344.24 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.10 | 318 | 792 | 3.86 / 345.03 | 2 | 7 |
Average= | 6.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 25 | 15.06 | 483 | 182 | 0.18 / 337.51 | 2 | 2 |
2 | 7 | 1901.80 | 38 | 14.62 | 2975 | 1653 | 1.83 / 339.16 | 2 | 3 |
3 | 13 | 1253.84 | 18 | 14.77 | 2168 | 576 | 2.41 / 339.73 | 2 | 4 |
4 | 13 | 813.24 | 18 | 14.87 | 1544 | 413 | 2.82 / 340.15 | 2 | 4 |
5 | 13 | 316.88 | 18 | 15.05 | 829 | 225 | 3.05 / 340.37 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.11 | 319 | 795 | 3.84 / 341.17 | 2 | 9 |
Average= | 6.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 25 | 15.07 | 488 | 184 | 0.18 / 333.67 | 2 | 3 |
2 | 7 | 1905.72 | 38 | 14.62 | 2982 | 1657 | 1.84 / 335.33 | 2 | 4 |
3 | 13 | 1301.84 | 18 | 14.74 | 2222 | 590 | 2.43 / 335.92 | 2 | 3 |
4 | 13 | 749.52 | 18 | 14.88 | 1461 | 391 | 2.82 / 336.31 | 2 | 4 |
5 | 13 | 318.48 | 18 | 15.02 | 824 | 223 | 3.04 / 336.53 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.11 | 318 | 793 | 3.84 / 337.32 | 2 | 9 |
Average= | 6.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 25 | 15.06 | 494 | 186 | 0.19 / 329.84 | 2 | 2 |
2 | 7 | 1901.96 | 38 | 14.61 | 2971 | 1649 | 1.84 / 331.49 | 2 | 3 |
3 | 13 | 1269.32 | 18 | 14.77 | 2173 | 578 | 2.41 / 332.07 | 2 | 3 |
4 | 13 | 766.96 | 18 | 14.89 | 1482 | 397 | 2.81 / 332.46 | 2 | 4 |
5 | 13 | 325.16 | 18 | 15.04 | 831 | 225 | 3.04 / 332.69 | 2 | 5 |
6 | 8 | 0.12 | 165 | 15.11 | 320 | 798 | 3.83 / 333.49 | 2 | 13 |
Average= | 6.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 25 | 15.07 | 497 | 187 | 0.19 / 326.00 | 2 | 3 |
2 | 7 | 1903.28 | 38 | 14.61 | 2972 | 1650 | 1.84 / 327.65 | 2 | 3 |
3 | 13 | 1290.48 | 18 | 14.76 | 2209 | 587 | 2.42 / 328.24 | 2 | 4 |
4 | 13 | 753.72 | 18 | 14.88 | 1469 | 393 | 2.82 / 328.63 | 2 | 4 |
5 | 13 | 321.08 | 18 | 15.04 | 829 | 224 | 3.04 / 328.86 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.11 | 319 | 795 | 3.84 / 329.65 | 2 | 8 |
Average= | 6.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 25 | 15.07 | 486 | 183 | 0.18 / 322.13 | 2 | 2 |
2 | 7 | 1903.24 | 38 | 14.62 | 2974 | 1652 | 1.84 / 323.78 | 2 | 3 |
3 | 13 | 1340.64 | 18 | 14.74 | 2275 | 604 | 2.44 / 324.39 | 2 | 4 |
4 | 13 | 838.32 | 18 | 14.87 | 1577 | 422 | 2.86 / 324.81 | 2 | 4 |
5 | 13 | 281.44 | 18 | 15.07 | 769 | 209 | 3.07 / 325.02 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.11 | 321 | 800 | 3.87 / 325.82 | 2 | 10 |
Average= | 6.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.92 | 25 | 15.08 | 509 | 192 | 0.19 / 318.23 | 2 | 2 |
2 | 7 | 1904.08 | 39 | 14.59 | 2971 | 1691 | 1.88 / 319.92 | 2 | 3 |
3 | 13 | 1345.24 | 18 | 14.72 | 2281 | 604 | 2.49 / 320.53 | 2 | 4 |
4 | 13 | 781.16 | 18 | 14.87 | 1508 | 404 | 2.89 / 320.93 | 2 | 5 |
5 | 13 | 289.92 | 18 | 15.05 | 788 | 213 | 3.10 / 321.15 | 2 | 4 |
6 | 8 | 0.24 | 165 | 15.12 | 321 | 801 | 3.90 / 321.95 | 2 | 8 |
Average= | 6.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 25 | 15.07 | 492 | 185 | 0.19 / 314.39 | 2 | 2 |
2 | 7 | 1902.92 | 38 | 14.61 | 2974 | 1651 | 1.84 / 316.04 | 2 | 3 |
3 | 13 | 1249.84 | 18 | 14.76 | 2135 | 567 | 2.40 / 316.61 | 2 | 4 |
4 | 13 | 812.44 | 18 | 14.87 | 1541 | 412 | 2.82 / 317.02 | 2 | 4 |
5 | 13 | 306.88 | 18 | 15.04 | 809 | 219 | 3.04 / 317.24 | 2 | 4 |
6 | 8 | -0.20 | 165 | 15.11 | 321 | 800 | 3.84 / 318.04 | 2 | 7 |
Average= | 6.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 25 | 15.08 | 487 | 184 | 0.18 / 310.18 | 2 | 2 |
2 | 7 | 1903.92 | 38 | 14.63 | 2978 | 1656 | 1.84 / 311.83 | 2 | 3 |
3 | 13 | 1334.00 | 18 | 14.75 | 2265 | 601 | 2.44 / 312.43 | 2 | 3 |
4 | 13 | 780.88 | 18 | 14.91 | 1502 | 403 | 2.84 / 312.84 | 2 | 4 |
5 | 13 | 296.16 | 18 | 15.06 | 795 | 216 | 3.06 / 313.05 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.12 | 319 | 796 | 3.86 / 313.85 | 2 | 10 |
7 | 14 | 0.08 | 75 | 15.08 | 316 | 357 | 4.21 / 314.21 | 2 | 15 |
Average= | 6.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 25 | 15.08 | 498 | 188 | 0.19 / 306.38 | 2 | 2 |
2 | 7 | 1902.92 | 38 | 14.61 | 2971 | 1649 | 1.84 / 308.03 | 2 | 4 |
3 | 13 | 1351.96 | 18 | 14.73 | 2290 | 607 | 2.44 / 308.64 | 2 | 3 |
4 | 13 | 757.36 | 18 | 14.90 | 1466 | 393 | 2.84 / 309.03 | 2 | 5 |
5 | 13 | 220.88 | 18 | 15.09 | 670 | 182 | 3.02 / 309.21 | 2 | 4 |
6 | 8 | -0.16 | 165 | 15.12 | 314 | 783 | 3.80 / 309.99 | 2 | 8 |
Average= | 6.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 25 | 15.08 | 496 | 187 | 0.19 / 302.54 | 2 | 2 |
2 | 7 | 1903.80 | 39 | 14.61 | 2979 | 1697 | 1.88 / 304.24 | 2 | 3 |
3 | 13 | 1325.24 | 18 | 14.74 | 2253 | 598 | 2.48 / 304.84 | 2 | 4 |
4 | 13 | 721.44 | 18 | 14.91 | 1417 | 380 | 2.86 / 305.22 | 2 | 4 |
5 | 13 | 236.64 | 18 | 15.08 | 702 | 191 | 3.05 / 305.41 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.13 | 314 | 784 | 3.84 / 306.19 | 2 | 11 |
Average= | 6.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 25 | 15.09 | 475 | 179 | 0.18 / 298.71 | 2 | 2 |
2 | 7 | 1903.32 | 38 | 14.61 | 2977 | 1653 | 1.83 / 300.36 | 2 | 3 |
3 | 13 | 1319.60 | 18 | 14.76 | 2240 | 595 | 2.43 / 300.96 | 2 | 3 |
4 | 13 | 749.36 | 18 | 14.91 | 1458 | 391 | 2.82 / 301.35 | 2 | 4 |
5 | 13 | 311.40 | 18 | 15.05 | 813 | 220 | 3.04 / 301.57 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.12 | 315 | 786 | 3.82 / 302.35 | 2 | 7 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 25 | 15.10 | 483 | 182 | 0.18 / 294.88 | 2 | 3 |
2 | 7 | 1902.64 | 39 | 14.63 | 2977 | 1699 | 1.88 / 296.58 | 2 | 3 |
3 | 13 | 1264.32 | 18 | 14.77 | 2159 | 574 | 2.45 / 297.16 | 2 | 3 |
4 | 13 | 719.40 | 18 | 14.92 | 1409 | 378 | 2.83 / 297.54 | 2 | 4 |
5 | 13 | 279.44 | 18 | 15.07 | 763 | 207 | 3.04 / 297.74 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.14 | 315 | 787 | 3.83 / 298.53 | 2 | 11 |
Average= | 6.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 25 | 15.10 | 494 | 186 | 0.19 / 291.05 | 2 | 2 |
2 | 7 | 1901.40 | 38 | 14.62 | 2977 | 1654 | 1.84 / 292.71 | 2 | 3 |
3 | 13 | 1333.96 | 18 | 14.77 | 2260 | 601 | 2.44 / 293.31 | 2 | 4 |
4 | 13 | 783.20 | 18 | 14.91 | 1520 | 408 | 2.85 / 293.71 | 2 | 4 |
5 | 13 | 247.68 | 18 | 15.11 | 714 | 194 | 3.04 / 293.91 | 2 | 4 |
6 | 8 | -0.12 | 165 | 15.13 | 318 | 794 | 3.84 / 294.70 | 2 | 9 |
Average= | 6.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 25 | 15.09 | 477 | 180 | 0.18 / 287.20 | 2 | 2 |
2 | 7 | 1903.36 | 38 | 14.63 | 2975 | 1654 | 1.83 / 288.86 | 2 | 4 |
3 | 13 | 1278.72 | 18 | 14.79 | 2184 | 581 | 2.42 / 289.44 | 2 | 3 |
4 | 13 | 779.92 | 18 | 14.91 | 1503 | 403 | 2.82 / 289.84 | 2 | 4 |
5 | 13 | 339.76 | 18 | 15.07 | 861 | 234 | 3.05 / 290.08 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.14 | 316 | 789 | 3.84 / 290.86 | 2 | 8 |
Average= | 6.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 25 | 15.12 | 477 | 180 | 0.18 / 283.33 | 2 | 3 |
2 | 7 | 1905.52 | 38 | 14.64 | 2975 | 1655 | 1.84 / 284.98 | 2 | 3 |
3 | 13 | 1194.04 | 18 | 14.81 | 2078 | 554 | 2.39 / 285.54 | 2 | 3 |
4 | 13 | 722.60 | 18 | 14.93 | 1432 | 385 | 2.77 / 285.92 | 2 | 4 |
5 | 13 | 287.00 | 18 | 15.09 | 778 | 211 | 2.99 / 286.13 | 2 | 4 |
6 | 13 | 26.24 | 18 | 15.17 | 366 | 100 | 3.09 / 286.23 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.13 | 317 | 791 | 3.88 / 287.02 | 2 | 9 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 25 | 15.10 | 475 | 179 | 0.18 / 279.45 | 2 | 3 |
2 | 7 | 1902.52 | 38 | 14.63 | 2969 | 1651 | 1.83 / 281.11 | 2 | 3 |
3 | 13 | 1224.88 | 18 | 14.80 | 2107 | 561 | 2.39 / 281.67 | 2 | 3 |
4 | 13 | 743.92 | 18 | 14.93 | 1455 | 391 | 2.78 / 282.06 | 2 | 4 |
5 | 13 | 254.64 | 18 | 15.11 | 734 | 200 | 2.98 / 282.26 | 2 | 4 |
6 | 13 | 43.24 | 18 | 15.19 | 391 | 107 | 3.09 / 282.36 | 2 | 4 |
7 | 8 | 0.20 | 165 | 15.15 | 313 | 782 | 3.87 / 283.15 | 2 | 10 |
Average= | 6.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 25 | 15.11 | 495 | 187 | 0.19 / 275.41 | 2 | 2 |
2 | 7 | 1905.28 | 38 | 14.63 | 2974 | 1653 | 1.84 / 277.06 | 2 | 3 |
3 | 13 | 1245.16 | 18 | 14.79 | 2131 | 567 | 2.41 / 277.63 | 2 | 3 |
4 | 13 | 1151.16 | 18 | 14.78 | 2020 | 537 | 2.95 / 278.17 | 2 | 4 |
5 | 13 | 292.04 | 18 | 15.10 | 791 | 215 | 3.16 / 278.38 | 2 | 4 |
6 | 13 | 30.24 | 18 | 15.18 | 375 | 102 | 3.26 / 278.49 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.13 | 316 | 789 | 4.05 / 279.28 | 2 | 10 |
Average= | 6.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 24 | 15.11 | 476 | 173 | 0.17 / 271.50 | 2 | 2 |
2 | 7 | 1902.76 | 38 | 14.64 | 2979 | 1657 | 1.83 / 273.16 | 2 | 3 |
3 | 13 | 1331.72 | 18 | 14.79 | 2248 | 598 | 2.43 / 273.75 | 2 | 4 |
4 | 13 | 770.24 | 18 | 14.94 | 1488 | 400 | 2.83 / 274.15 | 2 | 5 |
5 | 13 | 229.44 | 18 | 15.12 | 692 | 188 | 3.02 / 274.34 | 2 | 4 |
6 | 13 | 27.40 | 18 | 15.19 | 364 | 100 | 3.12 / 274.44 | 2 | 4 |
7 | 8 | 0.00 | 165 | 15.15 | 313 | 782 | 3.90 / 275.22 | 2 | 9 |
Average= | 7.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 24 | 15.12 | 476 | 173 | 0.17 / 267.68 | 2 | 2 |
2 | 7 | 1903.60 | 38 | 14.63 | 2974 | 1653 | 1.83 / 269.33 | 2 | 3 |
3 | 13 | 1217.36 | 18 | 14.81 | 2101 | 560 | 2.39 / 269.89 | 2 | 3 |
4 | 13 | 736.00 | 18 | 14.92 | 1439 | 386 | 2.77 / 270.28 | 2 | 4 |
5 | 13 | 197.56 | 18 | 15.13 | 640 | 174 | 2.95 / 270.45 | 2 | 4 |
6 | 13 | 23.92 | 18 | 15.19 | 358 | 98 | 3.04 / 270.55 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.15 | 311 | 777 | 3.82 / 271.33 | 2 | 9 |
Average= | 7.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 24 | 15.11 | 492 | 178 | 0.18 / 263.71 | 2 | 2 |
2 | 7 | 1902.88 | 39 | 14.64 | 2983 | 1703 | 1.88 / 265.42 | 2 | 3 |
3 | 13 | 1229.84 | 18 | 14.82 | 2130 | 568 | 2.45 / 265.99 | 2 | 3 |
4 | 13 | 794.72 | 18 | 14.92 | 1530 | 411 | 2.86 / 266.40 | 2 | 4 |
5 | 13 | 294.56 | 18 | 15.10 | 797 | 217 | 3.08 / 266.61 | 2 | 4 |
6 | 13 | 31.92 | 18 | 15.20 | 374 | 102 | 3.18 / 266.72 | 2 | 4 |
7 | 8 | 0.00 | 165 | 15.15 | 315 | 787 | 3.97 / 267.50 | 2 | 9 |
Average= | 7.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 25 | 15.13 | 477 | 180 | 0.18 / 259.78 | 2 | 3 |
2 | 7 | 1903.28 | 38 | 14.64 | 2976 | 1656 | 1.84 / 261.44 | 2 | 3 |
3 | 13 | 1315.12 | 18 | 14.79 | 2237 | 596 | 2.43 / 262.03 | 2 | 3 |
4 | 13 | 753.76 | 18 | 14.95 | 1460 | 393 | 2.82 / 262.42 | 2 | 4 |
5 | 13 | 301.60 | 18 | 15.11 | 795 | 216 | 3.04 / 262.64 | 2 | 4 |
6 | 13 | 29.44 | 18 | 15.19 | 377 | 103 | 3.14 / 262.74 | 2 | 4 |
7 | 8 | -0.08 | 165 | 15.15 | 317 | 792 | 3.94 / 263.54 | 2 | 10 |
Average= | 7.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 25 | 15.12 | 488 | 184 | 0.18 / 255.86 | 2 | 2 |
2 | 7 | 1903.12 | 39 | 14.64 | 2976 | 1699 | 1.88 / 257.56 | 2 | 4 |
3 | 13 | 1243.88 | 18 | 14.81 | 2143 | 571 | 2.45 / 258.13 | 2 | 3 |
4 | 13 | 715.04 | 18 | 14.96 | 1410 | 380 | 2.83 / 258.51 | 2 | 4 |
5 | 13 | 239.00 | 18 | 15.13 | 706 | 192 | 3.03 / 258.71 | 2 | 4 |
6 | 13 | 27.80 | 18 | 15.20 | 372 | 102 | 3.13 / 258.81 | 2 | 4 |
7 | 8 | -0.12 | 165 | 15.16 | 317 | 793 | 3.92 / 259.60 | 2 | 10 |
Average= | 7.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 25 | 15.14 | 483 | 183 | 0.18 / 251.93 | 2 | 3 |
2 | 7 | 1903.96 | 38 | 14.65 | 2974 | 1656 | 1.84 / 253.59 | 2 | 3 |
3 | 13 | 1237.44 | 18 | 14.84 | 2142 | 572 | 2.41 / 254.16 | 2 | 4 |
4 | 13 | 747.40 | 18 | 14.95 | 1454 | 391 | 2.80 / 254.55 | 2 | 4 |
5 | 13 | 311.80 | 18 | 15.11 | 819 | 223 | 3.02 / 254.77 | 2 | 4 |
6 | 13 | 15.84 | 18 | 15.21 | 355 | 97 | 3.12 / 254.87 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.17 | 322 | 806 | 3.93 / 255.68 | 2 | 9 |
Average= | 7.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 25 | 15.13 | 494 | 187 | 0.19 / 247.96 | 2 | 3 |
2 | 7 | 1902.40 | 38 | 14.65 | 2981 | 1660 | 1.85 / 249.62 | 2 | 4 |
3 | 13 | 1384.20 | 18 | 14.78 | 2337 | 622 | 2.47 / 250.25 | 2 | 4 |
4 | 13 | 804.88 | 18 | 14.94 | 1534 | 413 | 2.88 / 250.66 | 2 | 4 |
5 | 13 | 250.04 | 18 | 15.14 | 729 | 199 | 3.08 / 250.86 | 2 | 4 |
6 | 13 | 18.16 | 18 | 15.21 | 356 | 97 | 3.18 / 250.95 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.17 | 318 | 796 | 3.97 / 251.75 | 2 | 8 |
Average= | 7.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 25 | 15.15 | 490 | 186 | 0.19 / 244.03 | 2 | 2 |
2 | 7 | 1905.04 | 38 | 14.65 | 2979 | 1658 | 1.84 / 245.69 | 2 | 3 |
3 | 13 | 1325.00 | 18 | 14.81 | 2253 | 601 | 2.44 / 246.29 | 2 | 3 |
4 | 13 | 762.88 | 18 | 14.95 | 1486 | 400 | 2.84 / 246.69 | 2 | 4 |
5 | 13 | 217.92 | 18 | 15.15 | 677 | 185 | 3.03 / 246.88 | 2 | 4 |
6 | 13 | 21.12 | 18 | 15.21 | 360 | 99 | 3.13 / 246.98 | 2 | 4 |
7 | 8 | -0.12 | 165 | 15.18 | 320 | 802 | 3.93 / 247.78 | 2 | 11 |
Average= | 7.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 25 | 15.15 | 479 | 181 | 0.18 / 240.19 | 2 | 2 |
2 | 7 | 1903.20 | 38 | 14.66 | 2979 | 1660 | 1.84 / 241.85 | 2 | 4 |
3 | 13 | 1347.12 | 18 | 14.80 | 2277 | 607 | 2.45 / 242.45 | 2 | 4 |
4 | 13 | 784.72 | 18 | 14.95 | 1512 | 407 | 2.85 / 242.86 | 2 | 4 |
5 | 13 | 242.80 | 18 | 15.14 | 715 | 195 | 3.05 / 243.06 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.19 | 316 | 792 | 3.84 / 243.85 | 2 | 10 |
Average= | 7.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 24 | 15.16 | 486 | 177 | 0.18 / 236.27 | 2 | 3 |
2 | 3 | 1017.08 | 1 | 15.17 | 1869 | 28 | 0.21 / 236.30 | 2 | 3 |
3 | 7 | 1907.00 | 38 | 14.65 | 2985 | 1662 | 1.87 / 237.96 | 2 | 3 |
4 | 13 | 1357.40 | 18 | 14.80 | 2295 | 611 | 2.48 / 238.57 | 2 | 4 |
5 | 13 | 841.48 | 18 | 14.92 | 1596 | 429 | 2.91 / 239.00 | 2 | 5 |
6 | 13 | 298.16 | 18 | 15.13 | 798 | 217 | 3.12 / 239.22 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.19 | 315 | 790 | 3.91 / 240.01 | 2 | 9 |
Average= | 8.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 24 | 15.14 | 483 | 176 | 0.18 / 232.45 | 2 | 3 |
2 | 7 | 1901.92 | 38 | 14.65 | 2982 | 1660 | 1.84 / 234.11 | 2 | 3 |
3 | 13 | 1194.92 | 18 | 14.86 | 2079 | 556 | 2.39 / 234.67 | 2 | 3 |
4 | 13 | 757.60 | 18 | 14.97 | 1476 | 398 | 2.79 / 235.07 | 2 | 4 |
5 | 13 | 309.64 | 18 | 15.12 | 820 | 223 | 3.01 / 235.29 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.19 | 320 | 802 | 3.81 / 236.09 | 2 | 9 |
Average= | 8.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 24 | 15.15 | 486 | 177 | 0.18 / 228.63 | 2 | 3 |
2 | 7 | 1902.40 | 38 | 14.64 | 2974 | 1654 | 1.83 / 230.28 | 2 | 3 |
3 | 13 | 1286.20 | 18 | 14.81 | 2196 | 585 | 2.42 / 230.87 | 2 | 4 |
4 | 13 | 785.80 | 18 | 14.95 | 1505 | 405 | 2.82 / 231.27 | 2 | 4 |
5 | 13 | 278.32 | 18 | 15.14 | 758 | 207 | 3.03 / 231.48 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.18 | 319 | 799 | 3.83 / 232.28 | 2 | 7 |
Average= | 8.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 24 | 15.14 | 487 | 177 | 0.18 / 224.80 | 2 | 2 |
2 | 7 | 1906.44 | 38 | 14.64 | 2986 | 1661 | 1.84 / 226.46 | 2 | 3 |
3 | 13 | 1254.76 | 18 | 14.82 | 2158 | 576 | 2.41 / 227.04 | 2 | 3 |
4 | 13 | 765.08 | 18 | 14.96 | 1485 | 400 | 2.81 / 227.44 | 2 | 4 |
5 | 13 | 275.12 | 18 | 15.13 | 762 | 208 | 3.02 / 227.65 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.20 | 321 | 805 | 3.83 / 228.45 | 2 | 9 |
Average= | 8.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 24 | 15.15 | 494 | 180 | 0.18 / 221.03 | 2 | 3 |
2 | 7 | 1903.00 | 38 | 14.65 | 2973 | 1655 | 1.83 / 222.69 | 2 | 4 |
3 | 13 | 1227.96 | 18 | 14.83 | 2113 | 564 | 2.40 / 223.25 | 2 | 4 |
4 | 13 | 740.76 | 18 | 14.96 | 1455 | 392 | 2.79 / 223.64 | 2 | 5 |
5 | 13 | 198.68 | 18 | 15.17 | 654 | 179 | 2.97 / 223.82 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.19 | 320 | 802 | 3.77 / 224.63 | 2 | 10 |
Average= | 8.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 24 | 15.15 | 501 | 182 | 0.18 / 217.28 | 2 | 3 |
2 | 7 | 1903.88 | 38 | 14.66 | 2979 | 1660 | 1.84 / 218.94 | 2 | 4 |
3 | 13 | 1195.08 | 18 | 14.86 | 2084 | 557 | 2.40 / 219.50 | 2 | 4 |
4 | 13 | 668.24 | 18 | 15.01 | 1351 | 365 | 2.76 / 219.86 | 2 | 4 |
5 | 13 | 228.60 | 18 | 15.17 | 691 | 189 | 2.95 / 220.05 | 2 | 4 |
6 | 8 | -0.04 | 165 | 15.20 | 321 | 805 | 3.76 / 220.85 | 2 | 12 |
Average= | 8.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 24 | 15.15 | 494 | 180 | 0.18 / 213.40 | 2 | 2 |
2 | 3 | 1017.12 | 1 | 15.17 | 1905 | 29 | 0.21 / 213.43 | 2 | 3 |
3 | 7 | 1901.60 | 39 | 14.65 | 2988 | 1707 | 1.92 / 215.14 | 2 | 3 |
4 | 13 | 1234.80 | 18 | 14.83 | 2137 | 570 | 2.49 / 215.71 | 2 | 4 |
5 | 13 | 697.32 | 18 | 14.99 | 1385 | 374 | 2.86 / 216.08 | 2 | 4 |
6 | 13 | 218.64 | 18 | 15.17 | 684 | 187 | 3.05 / 216.27 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.20 | 330 | 828 | 3.87 / 217.10 | 2 | 13 |
Average= | 9.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 24 | 15.17 | 488 | 178 | 0.18 / 209.60 | 2 | 2 |
2 | 7 | 1901.84 | 38 | 14.68 | 2967 | 1655 | 1.83 / 211.26 | 2 | 3 |
3 | 13 | 1234.12 | 18 | 14.84 | 2131 | 569 | 2.40 / 211.83 | 2 | 4 |
4 | 13 | 736.00 | 18 | 14.99 | 1431 | 386 | 2.79 / 212.21 | 2 | 4 |
5 | 13 | 244.64 | 18 | 15.15 | 727 | 198 | 2.99 / 212.41 | 2 | 4 |
6 | 8 | -0.08 | 165 | 15.19 | 323 | 810 | 3.80 / 213.22 | 2 | 9 |
Average= | 9.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 24 | 15.17 | 481 | 175 | 0.18 / 205.77 | 2 | 2 |
2 | 7 | 1901.72 | 38 | 14.66 | 2967 | 1653 | 1.83 / 207.42 | 2 | 3 |
3 | 13 | 1349.32 | 18 | 14.82 | 2272 | 606 | 2.43 / 208.03 | 2 | 4 |
4 | 13 | 736.44 | 18 | 14.99 | 1438 | 388 | 2.82 / 208.42 | 2 | 4 |
5 | 13 | 256.96 | 18 | 15.15 | 732 | 200 | 3.02 / 208.62 | 2 | 4 |
6 | 8 | 0.24 | 165 | 15.22 | 322 | 809 | 3.83 / 209.43 | 2 | 8 |
Average= | 9.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 24 | 15.17 | 486 | 177 | 0.18 / 201.99 | 2 | 2 |
2 | 7 | 1903.52 | 38 | 14.67 | 2975 | 1658 | 1.84 / 203.64 | 2 | 3 |
3 | 13 | 1286.00 | 18 | 14.83 | 2188 | 584 | 2.42 / 204.23 | 2 | 3 |
4 | 13 | 735.08 | 18 | 14.99 | 1442 | 389 | 2.81 / 204.62 | 2 | 4 |
5 | 13 | 197.68 | 18 | 15.20 | 633 | 173 | 2.98 / 204.79 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.21 | 321 | 806 | 3.79 / 205.60 | 2 | 9 |
Average= | 9.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 24 | 15.16 | 486 | 177 | 0.18 / 198.17 | 2 | 2 |
2 | 7 | 1902.48 | 39 | 14.68 | 2968 | 1699 | 1.88 / 199.87 | 2 | 3 |
3 | 13 | 1234.16 | 18 | 14.85 | 2117 | 566 | 2.44 / 200.43 | 2 | 4 |
4 | 13 | 748.64 | 18 | 14.99 | 1452 | 392 | 2.83 / 200.82 | 2 | 4 |
5 | 13 | 217.32 | 18 | 15.19 | 669 | 183 | 3.02 / 201.01 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.21 | 319 | 801 | 3.82 / 201.81 | 2 | 8 |
Average= | 10.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 24 | 15.17 | 480 | 175 | 0.17 / 194.45 | 2 | 2 |
2 | 7 | 1904.04 | 38 | 14.65 | 2957 | 1646 | 1.82 / 196.09 | 2 | 3 |
3 | 13 | 1195.88 | 18 | 14.86 | 2062 | 552 | 2.37 / 196.64 | 2 | 4 |
4 | 13 | 726.48 | 18 | 14.99 | 1410 | 380 | 2.75 / 197.02 | 2 | 4 |
5 | 13 | 194.88 | 18 | 15.18 | 627 | 171 | 2.92 / 197.20 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.21 | 317 | 796 | 3.72 / 197.99 | 2 | 8 |
Average= | 10.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 24 | 15.18 | 490 | 179 | 0.18 / 190.62 | 2 | 3 |
2 | 7 | 1902.16 | 39 | 14.66 | 2968 | 1697 | 1.88 / 192.31 | 2 | 3 |
3 | 13 | 1231.28 | 18 | 14.88 | 2109 | 565 | 2.44 / 192.88 | 2 | 3 |
4 | 13 | 829.04 | 18 | 14.97 | 1569 | 423 | 2.86 / 193.30 | 2 | 4 |
5 | 13 | 215.20 | 18 | 15.19 | 662 | 181 | 3.04 / 193.48 | 2 | 4 |
6 | 8 | -0.16 | 165 | 15.22 | 314 | 789 | 3.83 / 194.27 | 2 | 10 |
Average= | 10.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 24 | 15.19 | 492 | 179 | 0.18 / 186.80 | 2 | 3 |
2 | 7 | 1901.56 | 38 | 14.67 | 2956 | 1648 | 1.83 / 188.45 | 2 | 3 |
3 | 13 | 1329.20 | 18 | 14.84 | 2244 | 599 | 2.43 / 189.05 | 2 | 4 |
4 | 13 | 771.16 | 18 | 15.00 | 1495 | 404 | 2.83 / 189.45 | 2 | 4 |
5 | 13 | 231.32 | 18 | 15.19 | 684 | 187 | 3.02 / 189.64 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.23 | 318 | 799 | 3.82 / 190.44 | 2 | 12 |
Average= | 11.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 24 | 15.19 | 499 | 182 | 0.18 / 182.98 | 2 | 2 |
2 | 7 | 1903.96 | 38 | 14.67 | 2967 | 1654 | 1.84 / 184.64 | 2 | 3 |
3 | 13 | 1338.28 | 18 | 14.84 | 2260 | 604 | 2.44 / 185.24 | 2 | 3 |
4 | 13 | 772.20 | 18 | 15.01 | 1493 | 403 | 2.84 / 185.64 | 2 | 4 |
5 | 13 | 226.84 | 18 | 15.19 | 682 | 186 | 3.03 / 185.83 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.22 | 316 | 794 | 3.82 / 186.62 | 2 | 9 |
Average= | 11.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 24 | 15.20 | 495 | 181 | 0.18 / 179.26 | 2 | 2 |
2 | 7 | 1902.00 | 38 | 14.68 | 2963 | 1653 | 1.83 / 180.91 | 2 | 3 |
3 | 13 | 1171.60 | 18 | 14.89 | 2035 | 545 | 2.38 / 181.45 | 2 | 4 |
4 | 13 | 738.00 | 18 | 15.01 | 1440 | 389 | 2.77 / 181.84 | 2 | 4 |
5 | 13 | 152.84 | 18 | 15.22 | 572 | 157 | 2.92 / 182.00 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.24 | 318 | 800 | 3.72 / 182.80 | 2 | 8 |
Average= | 12.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 24 | 15.21 | 497 | 181 | 0.18 / 175.05 | 2 | 2 |
2 | 7 | 1901.80 | 50 | 14.64 | 2962 | 2168 | 2.35 / 177.22 | 2 | 3 |
3 | 13 | 901.12 | 18 | 14.99 | 1657 | 447 | 2.80 / 177.66 | 2 | 4 |
4 | 13 | 335.96 | 18 | 15.17 | 852 | 233 | 3.03 / 177.90 | 2 | 4 |
5 | 8 | 0.08 | 165 | 15.26 | 324 | 816 | 3.85 / 178.71 | 2 | 8 |
6 | 14 | 0.08 | 75 | 15.23 | 318 | 363 | 4.21 / 179.08 | 2 | 15 |
Average= | 12.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 24 | 15.21 | 501 | 183 | 0.18 / 171.10 | 2 | 3 |
2 | 7 | 1903.64 | 51 | 14.65 | 2974 | 2222 | 2.40 / 173.32 | 2 | 3 |
3 | 13 | 899.84 | 18 | 14.97 | 1685 | 454 | 2.86 / 173.77 | 2 | 5 |
4 | 13 | 454.64 | 18 | 15.13 | 1042 | 284 | 3.14 / 174.06 | 2 | 5 |
5 | 8 | 0.36 | 165 | 15.26 | 322 | 811 | 3.95 / 174.87 | 2 | 9 |
Average= | 13.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 24 | 15.19 | 495 | 180 | 0.18 / 167.18 | 2 | 2 |
2 | 7 | 1903.76 | 50 | 14.66 | 2977 | 2182 | 2.36 / 169.36 | 2 | 3 |
3 | 13 | 909.76 | 18 | 14.99 | 1679 | 453 | 2.82 / 169.81 | 2 | 4 |
4 | 13 | 467.32 | 18 | 15.13 | 1056 | 288 | 3.10 / 170.10 | 2 | 4 |
5 | 8 | 0.24 | 165 | 15.25 | 323 | 813 | 3.92 / 170.91 | 2 | 9 |
Average= | 14.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 24 | 15.23 | 495 | 181 | 0.18 / 162.90 | 2 | 2 |
2 | 7 | 1903.44 | 50 | 14.66 | 2969 | 2176 | 2.36 / 165.07 | 2 | 3 |
3 | 13 | 919.80 | 18 | 14.98 | 1694 | 457 | 2.81 / 165.53 | 2 | 4 |
4 | 13 | 481.28 | 18 | 15.12 | 1062 | 289 | 3.10 / 165.82 | 2 | 4 |
5 | 8 | 0.24 | 165 | 15.26 | 323 | 813 | 3.92 / 166.63 | 2 | 11 |
6 | 14 | 0.24 | 75 | 15.22 | 321 | 366 | 4.28 / 167.00 | 3 | 10 |
Average= | 15.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 24 | 15.23 | 472 | 173 | 0.17 / 159.03 | 2 | 2 |
2 | 7 | 1904.68 | 50 | 14.68 | 2973 | 2182 | 2.35 / 161.22 | 2 | 4 |
3 | 13 | 910.76 | 18 | 14.99 | 1679 | 453 | 2.81 / 161.67 | 2 | 4 |
4 | 13 | 358.00 | 18 | 15.20 | 887 | 243 | 3.05 / 161.91 | 2 | 4 |
5 | 8 | -0.16 | 165 | 15.27 | 319 | 804 | 3.85 / 162.71 | 2 | 8 |
Average= | 16.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 24 | 15.23 | 510 | 186 | 0.19 / 154.56 | 2 | 2 |
2 | 3 | 1020.48 | 1 | 15.24 | 1890 | 29 | 0.22 / 154.59 | 2 | 3 |
3 | 7 | 1902.72 | 74 | 14.61 | 2972 | 3213 | 3.43 / 157.80 | 2 | 5 |
4 | 13 | 377.52 | 18 | 15.19 | 915 | 250 | 3.68 / 158.05 | 2 | 4 |
5 | 8 | 0.28 | 165 | 15.28 | 320 | 807 | 4.49 / 158.86 | 2 | 7 |
Average= | 17.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 24 | 15.24 | 490 | 179 | 0.18 / 150.11 | 2 | 2 |
2 | 3 | 1016.72 | 1 | 15.23 | 1904 | 29 | 0.21 / 150.14 | 2 | 3 |
3 | 7 | 1910.80 | 74 | 14.58 | 2976 | 3211 | 3.42 / 153.35 | 2 | 3 |
4 | 13 | 252.28 | 18 | 15.24 | 722 | 198 | 3.62 / 153.55 | 2 | 4 |
5 | 8 | 0.20 | 165 | 15.28 | 327 | 824 | 4.44 / 154.38 | 2 | 8 |
Average= | 19.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 24 | 15.24 | 498 | 182 | 0.18 / 145.51 | 2 | 2 |
2 | 7 | 1917.40 | 74 | 14.57 | 2997 | 3231 | 3.41 / 148.74 | 2 | 3 |
3 | 13 | 389.80 | 18 | 15.18 | 948 | 259 | 3.67 / 149.00 | 2 | 4 |
4 | 13 | 46.52 | 18 | 15.28 | 407 | 112 | 3.78 / 149.11 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.27 | 325 | 819 | 4.60 / 149.93 | 2 | 10 |
Average= | 21.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 24 | 15.24 | 470 | 172 | 0.17 / 141.71 | 2 | 2 |
2 | 7 | 1507.52 | 74 | 14.78 | 2447 | 2676 | 2.85 / 144.39 | 2 | 4 |
3 | 13 | 111.08 | 18 | 15.31 | 508 | 140 | 2.99 / 144.53 | 2 | 4 |
4 | 8 | 0.24 | 165 | 15.29 | 318 | 802 | 3.79 / 145.33 | 2 | 9 |
Average= | 24.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 24 | 15.24 | 491 | 180 | 0.18 / 137.86 | 2 | 2 |
2 | 3 | 1016.28 | 1 | 15.26 | 1866 | 28 | 0.21 / 137.89 | 2 | 3 |
3 | 7 | 1514.80 | 74 | 14.78 | 2470 | 2701 | 2.91 / 140.59 | 2 | 3 |
4 | 13 | 141.24 | 18 | 15.29 | 555 | 153 | 3.06 / 140.74 | 2 | 4 |
5 | 8 | 0.28 | 165 | 15.29 | 315 | 795 | 3.86 / 141.54 | 2 | 9 |
Average= | 28.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 23 | 15.31 | 510 | 180 | 0.18 / 133.63 | 2 | 2 |
2 | 3 | 1040.28 | 1 | 15.19 | 1924 | 29 | 0.21 / 133.66 | 2 | 3 |
3 | 7 | 1516.56 | 74 | 14.78 | 2457 | 2687 | 2.90 / 136.35 | 2 | 5 |
4 | 13 | 130.36 | 18 | 15.29 | 546 | 150 | 3.05 / 136.50 | 2 | 4 |
5 | 8 | 0.24 | 165 | 15.29 | 324 | 817 | 3.86 / 137.32 | 2 | 13 |
6 | 14 | 0.24 | 75 | 15.26 | 318 | 364 | 4.23 / 137.68 | 2 | 12 |
Average= | 34.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 23 | 15.29 | 498 | 175 | 0.18 / 130.59 | 2 | 2 |
2 | 3 | 1038.32 | 1 | 15.18 | 1914 | 29 | 0.20 / 130.62 | 2 | 3 |
3 | 7 | 1008.16 | 74 | 15.03 | 1793 | 1994 | 2.20 / 132.61 | 2 | 4 |
4 | 8 | 0.00 | 165 | 15.35 | 332 | 841 | 3.04 / 133.45 | 2 | 9 |
Average= | 44.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 11 | 15.33 | 509 | 86 | 0.09 / 127.13 | 2 | 2 |
2 | 10 | 1084.80 | 6 | 15.09 | 1957 | 177 | 0.26 / 127.31 | 2 | 3 |
3 | 10 | 1135.68 | 3 | 15.09 | 2031 | 92 | 0.35 / 127.40 | 2 | 3 |
4 | 3 | 1136.32 | 4 | 15.06 | 2031 | 122 | 0.48 / 127.52 | 2 | 3 |
5 | 3 | 1061.96 | 2 | 15.10 | 1981 | 60 | 0.54 / 127.58 | 2 | 3 |
6 | 7 | 1017.20 | 74 | 15.01 | 1799 | 1998 | 2.54 / 129.58 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.34 | 330 | 835 | 3.37 / 130.42 | 2 | 10 |
Average= | 65.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 1009.72 | 11 | 15.07 | 1869 | 310 | 0.31 / 123.48 | 2 | 2 |
2 | 2 | 1020.32 | 24 | 14.99 | 1846 | 664 | 0.97 / 124.14 | 2 | 3 |
3 | 2 | 1020.32 | 6 | 14.96 | 1858 | 167 | 1.14 / 124.31 | 2 | 3 |
4 | 3 | 517.48 | -9 | 15.59 | 0 | 0 | 0.83 / 124.31 | 2 | 3 |
5 | 3 | 793.00 | -4 | 15.62 | 1 | 0 | 0.83 / 124.31 | 2 | 3 |
6 | 7 | 931.20 | 75 | 15.08 | 1675 | 1894 | 3.04 / 126.20 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.36 | 332 | 841 | 3.88 / 127.05 | 2 | 11 |
Average= | 127.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 24 | 15.23 | 487 | 178 | 0.18 / 118.80 | 2 | 2 |
2 | 7 | 1913.68 | 75 | 14.58 | 2973 | 3251 | 3.43 / 122.05 | 2 | 3 |
3 | 13 | 257.76 | 18 | 15.23 | 740 | 203 | 3.63 / 122.25 | 2 | 4 |
4 | 13 | 24.32 | 18 | 15.30 | 370 | 102 | 3.73 / 122.35 | 2 | 4 |
5 | 8 | 0.36 | 165 | 15.27 | 323 | 814 | 4.55 / 123.17 | 2 | 10 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 24 | 15.24 | 476 | 174 | 0.17 / 114.23 | 2 | 2 |
2 | 7 | 1917.20 | 74 | 14.60 | 2982 | 3222 | 3.40 / 117.46 | 2 | 3 |
3 | 13 | 369.44 | 18 | 15.20 | 908 | 248 | 3.64 / 117.70 | 2 | 4 |
4 | 13 | 43.40 | 18 | 15.32 | 396 | 109 | 3.75 / 117.81 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.29 | 320 | 807 | 4.56 / 118.62 | 2 | 7 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 24 | 15.24 | 496 | 181 | 0.18 / 109.64 | 2 | 2 |
2 | 7 | 1913.00 | 75 | 14.60 | 2979 | 3262 | 3.44 / 112.90 | 2 | 3 |
3 | 13 | 360.88 | 18 | 15.19 | 896 | 245 | 3.69 / 113.15 | 2 | 4 |
4 | 13 | 21.76 | 18 | 15.32 | 367 | 101 | 3.79 / 113.25 | 2 | 4 |
5 | 8 | 0.12 | 165 | 15.28 | 322 | 812 | 4.60 / 114.06 | 2 | 10 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 24 | 15.25 | 478 | 175 | 0.17 / 105.12 | 2 | 2 |
2 | 7 | 1918.04 | 74 | 14.59 | 2982 | 3220 | 3.39 / 108.34 | 2 | 3 |
3 | 13 | 264.16 | 18 | 15.24 | 745 | 204 | 3.60 / 108.55 | 2 | 4 |
4 | 13 | 27.88 | 18 | 15.32 | 374 | 103 | 3.70 / 108.65 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.28 | 320 | 807 | 4.51 / 109.46 | 2 | 10 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 24 | 15.24 | 485 | 177 | 0.18 / 100.56 | 2 | 3 |
2 | 7 | 1915.88 | 74 | 14.60 | 2978 | 3217 | 3.39 / 103.78 | 2 | 3 |
3 | 13 | 376.72 | 18 | 15.20 | 919 | 251 | 3.65 / 104.03 | 2 | 4 |
4 | 13 | 25.24 | 18 | 15.32 | 373 | 103 | 3.75 / 104.14 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.28 | 323 | 814 | 4.56 / 104.95 | 2 | 9 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 24 | 15.24 | 492 | 180 | 0.18 / 95.97 | 2 | 2 |
2 | 7 | 1910.64 | 75 | 14.60 | 2967 | 3249 | 3.43 / 99.22 | 2 | 4 |
3 | 13 | 366.80 | 18 | 15.20 | 907 | 248 | 3.68 / 99.47 | 2 | 4 |
4 | 13 | 35.80 | 18 | 15.30 | 387 | 107 | 3.78 / 99.58 | 2 | 4 |
5 | 8 | 0.16 | 165 | 15.27 | 321 | 809 | 4.59 / 100.39 | 2 | 10 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 24 | 15.23 | 486 | 178 | 0.18 / 91.42 | 2 | 2 |
2 | 7 | 1914.08 | 74 | 14.61 | 2980 | 3222 | 3.40 / 94.64 | 2 | 4 |
3 | 13 | 364.76 | 18 | 15.22 | 901 | 247 | 3.65 / 94.89 | 2 | 4 |
4 | 13 | 19.64 | 18 | 15.32 | 361 | 100 | 3.75 / 94.98 | 2 | 4 |
5 | 8 | 0.20 | 165 | 15.28 | 321 | 809 | 4.56 / 95.79 | 2 | 10 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 24 | 15.23 | 491 | 179 | 0.18 / 86.83 | 2 | 3 |
2 | 7 | 1909.72 | 75 | 14.60 | 2968 | 3250 | 3.43 / 90.08 | 2 | 3 |
3 | 13 | 358.56 | 18 | 15.20 | 886 | 242 | 3.67 / 90.32 | 2 | 4 |
4 | 13 | 34.04 | 18 | 15.32 | 387 | 107 | 3.78 / 90.43 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.28 | 322 | 812 | 4.59 / 91.24 | 2 | 11 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 24 | 15.24 | 479 | 175 | 0.18 / 82.29 | 2 | 2 |
2 | 7 | 1909.28 | 74 | 14.62 | 2959 | 3201 | 3.38 / 85.50 | 2 | 4 |
3 | 13 | 370.04 | 18 | 15.19 | 905 | 247 | 3.62 / 85.74 | 2 | 4 |
4 | 13 | 22.88 | 18 | 15.32 | 366 | 101 | 3.72 / 85.84 | 2 | 4 |
5 | 8 | 0.12 | 165 | 15.28 | 319 | 804 | 4.53 / 86.65 | 2 | 10 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 24 | 15.25 | 485 | 178 | 0.18 / 77.77 | 2 | 2 |
2 | 7 | 1908.32 | 75 | 14.62 | 2962 | 3248 | 3.43 / 81.02 | 2 | 4 |
3 | 13 | 240.48 | 18 | 15.26 | 703 | 193 | 3.62 / 81.21 | 2 | 4 |
4 | 13 | 45.24 | 18 | 15.31 | 395 | 109 | 3.73 / 81.32 | 2 | 4 |
5 | 8 | 0.08 | 165 | 15.28 | 318 | 802 | 4.53 / 82.12 | 2 | 9 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 24 | 15.25 | 490 | 179 | 0.18 / 73.22 | 2 | 2 |
2 | 7 | 1911.00 | 74 | 14.62 | 2968 | 3211 | 3.39 / 76.43 | 2 | 4 |
3 | 13 | 370.44 | 18 | 15.20 | 903 | 247 | 3.64 / 76.68 | 2 | 4 |
4 | 13 | 40.80 | 18 | 15.32 | 398 | 110 | 3.75 / 76.79 | 2 | 4 |
5 | 8 | 0.16 | 165 | 15.28 | 319 | 804 | 4.55 / 77.59 | 2 | 10 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 24 | 15.25 | 496 | 182 | 0.18 / 68.68 | 2 | 2 |
2 | 7 | 1910.72 | 74 | 14.63 | 2973 | 3219 | 3.40 / 71.89 | 2 | 3 |
3 | 13 | 367.36 | 18 | 15.21 | 901 | 247 | 3.65 / 72.14 | 2 | 4 |
4 | 13 | 22.92 | 18 | 15.33 | 362 | 100 | 3.75 / 72.24 | 2 | 4 |
5 | 8 | 0.08 | 165 | 15.30 | 316 | 798 | 4.54 / 73.04 | 2 | 9 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 24 | 15.26 | 484 | 177 | 0.18 / 64.11 | 2 | 2 |
2 | 7 | 1902.96 | 74 | 14.62 | 2970 | 3213 | 3.39 / 67.32 | 2 | 6 |
3 | 13 | 343.96 | 18 | 15.24 | 871 | 239 | 3.63 / 67.56 | 2 | 4 |
4 | 13 | 17.72 | 18 | 15.34 | 370 | 102 | 3.73 / 67.66 | 2 | 4 |
5 | 8 | 0.08 | 165 | 15.29 | 330 | 833 | 4.56 / 68.49 | 2 | 9 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 24 | 15.26 | 496 | 182 | 0.18 / 59.63 | 2 | 2 |
2 | 7 | 1905.20 | 74 | 14.64 | 2958 | 3205 | 3.39 / 62.83 | 2 | 3 |
3 | 13 | 243.52 | 18 | 15.28 | 710 | 195 | 3.58 / 63.02 | 2 | 4 |
4 | 13 | 22.00 | 18 | 15.34 | 365 | 101 | 3.68 / 63.13 | 2 | 4 |
5 | 8 | 0.24 | 165 | 15.29 | 319 | 805 | 4.49 / 63.93 | 2 | 9 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 24 | 15.25 | 491 | 180 | 0.18 / 55.12 | 2 | 2 |
2 | 7 | 1916.92 | 74 | 14.64 | 2982 | 3231 | 3.41 / 58.35 | 2 | 3 |
3 | 13 | 237.04 | 18 | 15.27 | 697 | 192 | 3.60 / 58.54 | 2 | 4 |
4 | 13 | 23.12 | 18 | 15.32 | 366 | 101 | 3.70 / 58.64 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.29 | 318 | 802 | 4.51 / 59.44 | 2 | 9 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 24 | 15.26 | 486 | 178 | 0.18 / 50.56 | 2 | 2 |
2 | 7 | 1911.88 | 74 | 14.64 | 2971 | 3219 | 3.40 / 53.78 | 2 | 6 |
3 | 13 | 360.96 | 18 | 15.21 | 893 | 244 | 3.64 / 54.02 | 2 | 4 |
4 | 13 | 17.16 | 18 | 15.33 | 357 | 99 | 3.74 / 54.12 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.30 | 324 | 818 | 4.56 / 54.94 | 2 | 9 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 24 | 15.27 | 488 | 179 | 0.18 / 46.13 | 2 | 2 |
2 | 7 | 1908.48 | 75 | 14.63 | 2961 | 3249 | 3.43 / 49.38 | 2 | 5 |
3 | 13 | 230.92 | 18 | 15.26 | 697 | 191 | 3.62 / 49.57 | 2 | 4 |
4 | 8 | 0.00 | 165 | 15.30 | 320 | 808 | 4.43 / 50.38 | 2 | 9 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 24 | 15.27 | 497 | 182 | 0.18 / 41.69 | 2 | 2 |
2 | 7 | 1905.64 | 74 | 14.65 | 2965 | 3214 | 3.40 / 44.90 | 2 | 4 |
3 | 13 | 358.60 | 18 | 15.23 | 891 | 244 | 3.64 / 45.14 | 2 | 4 |
4 | 8 | 0.16 | 165 | 15.32 | 320 | 809 | 4.45 / 45.95 | 2 | 8 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 24 | 15.26 | 496 | 182 | 0.18 / 37.21 | 2 | 2 |
2 | 7 | 1904.44 | 74 | 14.64 | 2974 | 3222 | 3.40 / 40.43 | 2 | 3 |
3 | 13 | 354.40 | 18 | 15.21 | 891 | 244 | 3.65 / 40.67 | 2 | 4 |
4 | 8 | 0.16 | 165 | 15.31 | 329 | 831 | 4.48 / 41.50 | 2 | 7 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 23 | 15.25 | 509 | 179 | 0.18 / 32.78 | 2 | 2 |
2 | 3 | 1017.32 | 1 | 15.25 | 1903 | 29 | 0.21 / 32.81 | 2 | 2 |
3 | 7 | 1903.96 | 74 | 14.63 | 2967 | 3212 | 3.42 / 36.02 | 2 | 3 |
4 | 13 | 231.52 | 18 | 15.27 | 687 | 189 | 3.61 / 36.21 | 2 | 4 |
5 | 8 | 0.28 | 165 | 15.31 | 323 | 816 | 4.42 / 37.03 | 2 | 9 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 22 | 15.24 | 512 | 172 | 0.17 / 28.22 | 2 | 2 |
2 | 3 | 1047.44 | 1 | 15.19 | 1920 | 29 | 0.20 / 28.25 | 2 | 3 |
3 | 7 | 1908.56 | 75 | 14.64 | 2984 | 3276 | 3.48 / 31.52 | 2 | 3 |
4 | 13 | 342.56 | 18 | 15.23 | 878 | 241 | 3.72 / 31.76 | 2 | 4 |
5 | 8 | 0.12 | 165 | 15.31 | 331 | 836 | 4.55 / 32.60 | 2 | 8 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 29 | 15.26 | 481 | 213 | 0.21 / 23.75 | 2 | 2 |
2 | 3 | 797.32 | -4 | 15.60 | 0 | 0 | 0.00 / 23.75 | 2 | 2 |
3 | 3 | 924.68 | -1 | 15.64 | 0 | 0 | 0.00 / 23.75 | 2 | 2 |
4 | 7 | 1901.64 | 74 | 14.65 | 2963 | 3212 | 3.43 / 26.96 | 2 | 3 |
5 | 13 | 363.00 | 18 | 15.24 | 898 | 246 | 3.67 / 27.21 | 2 | 4 |
6 | 8 | 0.36 | 165 | 15.30 | 332 | 838 | 4.51 / 28.05 | 2 | 8 |
Average= | 5.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 23 | 15.24 | 483 | 169 | 0.17 / 19.86 | 2 | 2 |
2 | 7 | 1507.76 | 75 | 14.81 | 2441 | 2711 | 2.88 / 22.58 | 2 | 3 |
3 | 13 | 104.24 | 18 | 15.33 | 502 | 139 | 3.02 / 22.71 | 2 | 3 |
4 | 8 | 0.20 | 165 | 15.30 | 326 | 823 | 3.84 / 23.54 | 2 | 8 |
Average= | 5.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 22 | 15.25 | 487 | 163 | 0.16 / 15.65 | 2 | 2 |
2 | 3 | 1037.16 | 1 | 15.20 | 1916 | 29 | 0.19 / 15.68 | 2 | 3 |
3 | 7 | 1509.84 | 74 | 14.82 | 2447 | 2684 | 2.88 / 18.37 | 2 | 3 |
4 | 13 | 112.24 | 18 | 15.32 | 512 | 141 | 3.02 / 18.51 | 2 | 3 |
5 | 8 | -0.16 | 165 | 15.30 | 325 | 820 | 3.84 / 19.33 | 2 | 7 |
6 | 14 | -0.16 | 75 | 15.26 | 321 | 367 | 4.21 / 19.70 | 3 | 10 |
Average= | 6.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 32 | 15.27 | 487 | 238 | 0.24 / 11.88 | 2 | 2 |
2 | 3 | 726.04 | -5 | 15.61 | 0 | 0 | 0.00 / 11.88 | 2 | 2 |
3 | 3 | 877.44 | -2 | 15.63 | 0 | 0 | 0.00 / 11.88 | 2 | 2 |
4 | 7 | 1507.40 | 74 | 14.81 | 2439 | 2673 | 2.91 / 14.55 | 2 | 3 |
5 | 13 | 106.16 | 18 | 15.31 | 491 | 135 | 3.05 / 14.68 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.30 | 319 | 805 | 3.85 / 15.49 | 2 | 10 |
Average= | 7.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 554.12 | 25 | 15.21 | 1133 | 431 | 0.43 / 8.88 | 2 | 2 |
2 | 3 | 882.40 | -2 | 15.59 | 1 | 0 | 0.00 / 8.88 | 2 | 2 |
3 | 3 | 954.76 | -1 | 15.62 | 1 | 0 | 0.00 / 8.88 | 2 | 2 |
4 | 7 | 986.88 | 74 | 15.00 | 1739 | 1930 | 2.36 / 10.81 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.31 | 326 | 824 | 3.18 / 11.64 | 2 | 10 |
Average= | 11.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 836.92 | 23 | 15.21 | 1603 | 561 | 0.56 / 5.60 | 2 | 3 |
2 | 10 | 1020.60 | 2 | 15.24 | 1872 | 57 | 0.62 / 5.66 | 2 | 3 |
3 | 7 | 1005.32 | 74 | 15.03 | 1773 | 1972 | 2.59 / 7.63 | 2 | 4 |
4 | 8 | 0.16 | 165 | 15.36 | 326 | 826 | 3.42 / 8.45 | 2 | 9 |
Average= | 8.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 951.00 | 27 | 15.17 | 1757 | 720 | 0.72 / 2.31 | 2 | 3 |
2 | 3 | 931.48 | -1 | 15.68 | 0 | 0 | 0.00 / 2.31 | 2 | 3 |
3 | 3 | 963.12 | -1 | 15.69 | 0 | 0 | 0.00 / 2.31 | 2 | 3 |
4 | 7 | 998.40 | 74 | 15.06 | 1748 | 1948 | 2.67 / 4.26 | 2 | 4 |
5 | 8 | -0.08 | 165 | 15.35 | 307 | 778 | 3.45 / 5.04 | 2 | 9 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 66.92 | 26 | 15.61 | 386 | 157 | 0.16 / 0.16 | 2 | 3 |
2 | 7 | 83.24 | 75 | 15.57 | 396 | 462 | 0.62 / 0.62 | 2 | 3 |
3 | 8 | 0.24 | 240 | 15.54 | 261 | 973 | 1.59 / 1.59 | 2 | 12 |
Average= | 1.59 (KJ/cycle) |