SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 28 | 14.95 | 570 | 239 | 0.24 / 476.39 | 2 | 2 |
2 | 12 | 1153.20 | 1 | 15.18 | 2127 | 32 | 0.27 / 476.42 | 2 | 2 |
3 | 7 | 2010.28 | 25 | 14.79 | 3245 | 1200 | 1.47 / 477.62 | 2 | 2 |
4 | 13 | 1880.96 | 18 | 14.69 | 3081 | 815 | 2.29 / 478.43 | 2 | 2 |
5 | 13 | 1141.60 | 18 | 14.78 | 2065 | 549 | 2.83 / 478.98 | 2 | 3 |
6 | 13 | 556.52 | 18 | 14.92 | 1244 | 334 | 3.17 / 479.32 | 2 | 4 |
7 | 13 | 141.84 | 18 | 15.04 | 630 | 171 | 3.34 / 479.49 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.00 | 414 | 1025 | 4.36 / 480.51 | 2 | 5 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 28 | 14.94 | 567 | 237 | 0.24 / 472.08 | 2 | 2 |
2 | 12 | 1159.56 | 1 | 15.16 | 2151 | 33 | 0.27 / 472.12 | 2 | 2 |
3 | 7 | 2009.84 | 25 | 14.76 | 3218 | 1187 | 1.46 / 473.30 | 2 | 2 |
4 | 13 | 1745.92 | 18 | 14.70 | 2898 | 767 | 2.22 / 474.07 | 2 | 2 |
5 | 13 | 1161.24 | 18 | 14.77 | 2081 | 553 | 2.78 / 474.62 | 2 | 3 |
6 | 13 | 550.20 | 18 | 14.91 | 1221 | 328 | 3.10 / 474.95 | 2 | 4 |
7 | 13 | 131.08 | 18 | 15.02 | 613 | 166 | 3.27 / 475.12 | 2 | 4 |
8 | 8 | 0.12 | 165 | 15.00 | 416 | 1030 | 4.30 / 476.15 | 2 | 5 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 28 | 14.92 | 583 | 244 | 0.24 / 467.66 | 2 | 2 |
2 | 12 | 1172.48 | 1 | 15.17 | 2148 | 33 | 0.28 / 467.69 | 2 | 2 |
3 | 7 | 2004.40 | 25 | 14.80 | 3220 | 1191 | 1.47 / 468.88 | 2 | 2 |
4 | 13 | 1736.44 | 18 | 14.70 | 2871 | 760 | 2.23 / 469.64 | 2 | 3 |
5 | 13 | 1157.40 | 18 | 14.78 | 2075 | 552 | 2.78 / 470.20 | 2 | 4 |
6 | 13 | 560.76 | 18 | 14.93 | 1241 | 334 | 3.11 / 470.53 | 2 | 4 |
7 | 13 | 137.92 | 18 | 15.05 | 624 | 169 | 3.28 / 470.70 | 2 | 3 |
8 | 13 | 30.24 | 18 | 15.06 | 457 | 124 | 3.41 / 470.82 | 2 | 2 |
9 | 8 | 0.00 | 165 | 15.00 | 414 | 1025 | 4.43 / 471.85 | 2 | 10 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 28 | 14.93 | 573 | 240 | 0.24 / 463.20 | 2 | 2 |
2 | 12 | 1183.68 | 1 | 15.16 | 2161 | 33 | 0.27 / 463.24 | 2 | 2 |
3 | 7 | 2004.32 | 26 | 14.77 | 3229 | 1240 | 1.51 / 464.48 | 2 | 2 |
4 | 13 | 1730.00 | 18 | 14.70 | 2873 | 760 | 2.27 / 465.24 | 2 | 3 |
5 | 13 | 1027.96 | 18 | 14.82 | 1904 | 508 | 2.78 / 465.75 | 2 | 4 |
6 | 13 | 582.60 | 18 | 14.90 | 1278 | 343 | 3.12 / 466.09 | 2 | 4 |
7 | 13 | 134.84 | 18 | 15.03 | 621 | 168 | 3.29 / 466.26 | 2 | 4 |
8 | 13 | 29.76 | 18 | 15.04 | 459 | 124 | 3.42 / 466.38 | 2 | 3 |
9 | 8 | 0.00 | 165 | 14.98 | 419 | 1036 | 4.45 / 467.42 | 2 | 7 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 28 | 14.94 | 584 | 244 | 0.24 / 458.87 | 2 | 2 |
2 | 12 | 1171.56 | 1 | 15.17 | 2169 | 33 | 0.28 / 458.90 | 2 | 2 |
3 | 7 | 2007.64 | 25 | 14.78 | 3212 | 1187 | 1.46 / 460.09 | 2 | 2 |
4 | 13 | 1740.08 | 18 | 14.70 | 2883 | 763 | 2.23 / 460.85 | 2 | 3 |
5 | 13 | 1026.48 | 18 | 14.81 | 1889 | 504 | 2.73 / 461.35 | 2 | 3 |
6 | 13 | 468.56 | 18 | 14.95 | 1114 | 300 | 3.03 / 461.65 | 2 | 4 |
7 | 13 | 108.00 | 18 | 15.06 | 582 | 158 | 3.19 / 461.81 | 2 | 3 |
8 | 13 | 26.16 | 18 | 15.05 | 452 | 122 | 3.31 / 461.93 | 2 | 2 |
9 | 8 | 0.12 | 165 | 14.99 | 417 | 1031 | 4.34 / 462.97 | 2 | 6 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 28 | 14.94 | 579 | 242 | 0.24 / 454.40 | 2 | 2 |
2 | 12 | 1172.20 | 1 | 15.18 | 2174 | 33 | 0.28 / 454.44 | 2 | 2 |
3 | 7 | 2007.08 | 25 | 14.82 | 3209 | 1189 | 1.46 / 455.63 | 2 | 2 |
4 | 13 | 1740.24 | 18 | 14.71 | 2875 | 761 | 2.23 / 456.39 | 2 | 3 |
5 | 13 | 1156.00 | 18 | 14.80 | 2081 | 554 | 2.78 / 456.94 | 2 | 3 |
6 | 13 | 558.28 | 18 | 14.93 | 1241 | 334 | 3.11 / 457.27 | 2 | 4 |
7 | 13 | 133.32 | 18 | 15.04 | 635 | 172 | 3.29 / 457.45 | 2 | 3 |
8 | 13 | 34.56 | 18 | 15.06 | 481 | 130 | 3.42 / 457.58 | 2 | 3 |
9 | 8 | 0.00 | 165 | 15.00 | 423 | 1047 | 4.46 / 458.62 | 2 | 7 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 27 | 14.94 | 567 | 229 | 0.23 / 449.90 | 2 | 2 |
2 | 12 | 1174.28 | 1 | 15.16 | 2162 | 33 | 0.26 / 449.94 | 2 | 2 |
3 | 7 | 2005.88 | 26 | 14.78 | 3212 | 1234 | 1.50 / 451.17 | 2 | 2 |
4 | 13 | 1743.68 | 18 | 14.71 | 2891 | 765 | 2.26 / 451.93 | 2 | 2 |
5 | 13 | 1162.84 | 18 | 14.78 | 2083 | 554 | 2.82 / 452.49 | 2 | 3 |
6 | 13 | 562.40 | 18 | 14.93 | 1246 | 335 | 3.15 / 452.82 | 2 | 4 |
7 | 13 | 136.12 | 18 | 15.04 | 632 | 171 | 3.32 / 452.99 | 2 | 3 |
8 | 13 | 29.96 | 18 | 15.06 | 458 | 124 | 3.45 / 453.12 | 2 | 4 |
9 | 8 | 0.04 | 165 | 15.00 | 421 | 1042 | 4.49 / 454.16 | 2 | 9 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 27 | 14.94 | 575 | 232 | 0.23 / 445.43 | 2 | 2 |
2 | 12 | 1162.48 | 1 | 15.16 | 2136 | 32 | 0.26 / 445.46 | 2 | 2 |
3 | 7 | 2011.24 | 25 | 14.80 | 3233 | 1196 | 1.46 / 446.66 | 2 | 2 |
4 | 13 | 1761.04 | 18 | 14.71 | 2917 | 772 | 2.23 / 447.43 | 2 | 2 |
5 | 13 | 1168.28 | 18 | 14.79 | 2096 | 558 | 2.79 / 447.99 | 2 | 3 |
6 | 13 | 592.56 | 18 | 14.91 | 1291 | 346 | 3.14 / 448.34 | 2 | 3 |
7 | 13 | 148.68 | 18 | 15.04 | 648 | 175 | 3.31 / 448.51 | 2 | 4 |
8 | 13 | 33.04 | 18 | 15.05 | 468 | 127 | 3.44 / 448.64 | 2 | 2 |
9 | 8 | -0.12 | 165 | 14.99 | 419 | 1036 | 4.48 / 449.67 | 2 | 10 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 27 | 14.94 | 561 | 226 | 0.23 / 441.12 | 2 | 2 |
2 | 12 | 1159.48 | 1 | 15.17 | 2129 | 32 | 0.26 / 441.16 | 2 | 2 |
3 | 7 | 2006.68 | 25 | 14.77 | 3218 | 1188 | 1.45 / 442.35 | 2 | 2 |
4 | 13 | 1605.64 | 18 | 14.74 | 2700 | 716 | 2.16 / 443.06 | 2 | 3 |
5 | 13 | 1049.16 | 18 | 14.80 | 1930 | 514 | 2.68 / 443.58 | 2 | 3 |
6 | 13 | 481.00 | 18 | 14.94 | 1135 | 305 | 2.98 / 443.88 | 2 | 3 |
7 | 13 | 105.84 | 18 | 15.05 | 586 | 159 | 3.14 / 444.04 | 2 | 3 |
8 | 13 | 25.00 | 18 | 15.05 | 458 | 124 | 3.27 / 444.16 | 2 | 4 |
9 | 8 | 0.04 | 165 | 14.99 | 418 | 1034 | 4.30 / 445.20 | 2 | 6 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 27 | 14.95 | 561 | 226 | 0.23 / 436.80 | 2 | 2 |
2 | 12 | 1179.52 | 1 | 15.17 | 2164 | 33 | 0.26 / 436.83 | 2 | 2 |
3 | 7 | 2005.96 | 25 | 14.82 | 3225 | 1195 | 1.45 / 438.03 | 2 | 2 |
4 | 13 | 1739.40 | 18 | 14.72 | 2877 | 762 | 2.22 / 438.79 | 2 | 2 |
5 | 13 | 1037.04 | 18 | 14.82 | 1911 | 510 | 2.73 / 439.30 | 2 | 3 |
6 | 13 | 475.24 | 18 | 14.94 | 1114 | 300 | 3.03 / 439.60 | 2 | 3 |
7 | 13 | 118.76 | 18 | 15.05 | 594 | 161 | 3.19 / 439.76 | 2 | 3 |
8 | 13 | 29.20 | 18 | 15.05 | 454 | 123 | 3.31 / 439.88 | 2 | 4 |
9 | 8 | -0.04 | 165 | 15.00 | 410 | 1015 | 4.32 / 440.90 | 2 | 12 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 27 | 14.95 | 566 | 228 | 0.23 / 432.46 | 2 | 2 |
2 | 12 | 1165.36 | 1 | 15.18 | 2136 | 32 | 0.26 / 432.49 | 2 | 2 |
3 | 7 | 2004.40 | 25 | 14.79 | 3205 | 1185 | 1.45 / 433.68 | 2 | 2 |
4 | 13 | 1747.24 | 18 | 14.71 | 2875 | 761 | 2.21 / 434.44 | 2 | 2 |
5 | 13 | 1025.68 | 18 | 14.84 | 1892 | 505 | 2.71 / 434.94 | 2 | 4 |
6 | 13 | 590.64 | 18 | 14.92 | 1283 | 345 | 3.06 / 435.29 | 2 | 3 |
7 | 13 | 101.96 | 18 | 15.05 | 568 | 154 | 3.21 / 435.44 | 2 | 6 |
8 | 13 | 23.56 | 18 | 15.06 | 445 | 121 | 3.33 / 435.56 | 2 | 4 |
9 | 8 | -0.08 | 165 | 15.00 | 409 | 1012 | 4.34 / 436.57 | 2 | 4 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 27 | 14.93 | 559 | 225 | 0.23 / 428.25 | 2 | 2 |
2 | 12 | 1163.88 | 1 | 15.18 | 2151 | 33 | 0.26 / 428.28 | 2 | 2 |
3 | 7 | 2009.68 | 26 | 14.77 | 3227 | 1239 | 1.50 / 429.52 | 2 | 2 |
4 | 13 | 1622.48 | 18 | 14.73 | 2724 | 722 | 2.22 / 430.24 | 2 | 2 |
5 | 13 | 1060.12 | 18 | 14.80 | 1943 | 518 | 2.74 / 430.76 | 2 | 3 |
6 | 13 | 484.88 | 18 | 14.94 | 1127 | 303 | 3.04 / 431.06 | 2 | 4 |
7 | 13 | 104.04 | 18 | 15.05 | 569 | 154 | 3.19 / 431.22 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.01 | 409 | 1013 | 4.21 / 432.23 | 2 | 6 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 27 | 14.95 | 558 | 225 | 0.23 / 423.87 | 2 | 2 |
2 | 12 | 1182.48 | 1 | 15.17 | 2166 | 33 | 0.26 / 423.90 | 2 | 2 |
3 | 7 | 2003.00 | 25 | 14.81 | 3192 | 1182 | 1.44 / 425.08 | 2 | 2 |
4 | 13 | 1742.80 | 18 | 14.71 | 2884 | 764 | 2.20 / 425.84 | 2 | 3 |
5 | 13 | 1155.24 | 18 | 14.78 | 2071 | 551 | 2.75 / 426.39 | 2 | 3 |
6 | 13 | 561.72 | 18 | 14.93 | 1236 | 332 | 3.09 / 426.73 | 2 | 3 |
7 | 13 | 140.88 | 18 | 15.04 | 626 | 169 | 3.26 / 426.90 | 2 | 4 |
8 | 13 | 31.68 | 18 | 15.05 | 450 | 122 | 3.38 / 427.02 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.00 | 406 | 1005 | 4.38 / 428.02 | 2 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 27 | 14.96 | 560 | 226 | 0.23 / 419.65 | 2 | 2 |
2 | 12 | 1155.72 | 1 | 15.17 | 2110 | 32 | 0.26 / 419.69 | 2 | 2 |
3 | 7 | 2009.32 | 26 | 14.77 | 3214 | 1234 | 1.49 / 420.92 | 2 | 2 |
4 | 13 | 1630.20 | 18 | 14.73 | 2723 | 722 | 2.21 / 421.64 | 2 | 2 |
5 | 13 | 1078.00 | 18 | 14.80 | 1958 | 522 | 2.74 / 422.16 | 2 | 3 |
6 | 13 | 499.52 | 18 | 14.95 | 1157 | 311 | 3.05 / 422.48 | 2 | 3 |
7 | 13 | 115.56 | 18 | 15.04 | 587 | 159 | 3.21 / 422.63 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.01 | 406 | 1006 | 4.21 / 423.64 | 2 | 7 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 27 | 14.94 | 558 | 225 | 0.23 / 415.47 | 2 | 2 |
2 | 12 | 1174.00 | 1 | 15.18 | 2152 | 33 | 0.26 / 415.50 | 2 | 2 |
3 | 7 | 2006.88 | 25 | 14.78 | 3215 | 1188 | 1.45 / 416.69 | 2 | 2 |
4 | 13 | 1735.88 | 18 | 14.72 | 2863 | 759 | 2.20 / 417.45 | 2 | 2 |
5 | 13 | 1031.04 | 18 | 14.83 | 1894 | 506 | 2.71 / 417.95 | 2 | 3 |
6 | 13 | 491.00 | 18 | 14.95 | 1140 | 307 | 3.02 / 418.26 | 2 | 3 |
7 | 13 | 126.60 | 18 | 15.05 | 594 | 161 | 3.18 / 418.42 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.02 | 407 | 1009 | 4.19 / 419.43 | 2 | 6 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 27 | 14.97 | 563 | 228 | 0.23 / 411.22 | 2 | 2 |
2 | 12 | 1169.44 | 1 | 15.17 | 2143 | 33 | 0.26 / 411.25 | 2 | 2 |
3 | 7 | 2009.48 | 25 | 14.78 | 3211 | 1186 | 1.45 / 412.43 | 2 | 3 |
4 | 13 | 1742.36 | 18 | 14.72 | 2878 | 763 | 2.21 / 413.20 | 2 | 2 |
5 | 13 | 1156.76 | 18 | 14.78 | 2076 | 552 | 2.76 / 413.75 | 2 | 3 |
6 | 13 | 553.16 | 18 | 14.93 | 1232 | 331 | 3.09 / 414.08 | 2 | 4 |
7 | 13 | 141.04 | 18 | 15.04 | 621 | 168 | 3.26 / 414.25 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.01 | 401 | 993 | 4.25 / 415.24 | 2 | 4 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 27 | 14.97 | 550 | 222 | 0.22 / 406.94 | 2 | 2 |
2 | 12 | 1162.08 | 1 | 15.17 | 2131 | 32 | 0.25 / 406.97 | 2 | 2 |
3 | 7 | 2006.20 | 25 | 14.81 | 3220 | 1192 | 1.45 / 408.16 | 2 | 2 |
4 | 13 | 1754.16 | 18 | 14.71 | 2893 | 766 | 2.21 / 408.93 | 2 | 2 |
5 | 13 | 1164.28 | 18 | 14.78 | 2081 | 554 | 2.77 / 409.48 | 2 | 3 |
6 | 13 | 582.52 | 18 | 14.92 | 1263 | 339 | 3.11 / 409.82 | 2 | 4 |
7 | 13 | 147.84 | 18 | 15.04 | 631 | 171 | 3.28 / 409.99 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.00 | 402 | 995 | 4.27 / 410.99 | 2 | 5 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 27 | 14.96 | 556 | 225 | 0.22 / 402.67 | 2 | 2 |
2 | 12 | 1163.76 | 1 | 15.18 | 2145 | 33 | 0.26 / 402.70 | 2 | 2 |
3 | 7 | 2008.68 | 25 | 14.81 | 3211 | 1189 | 1.45 / 403.89 | 2 | 2 |
4 | 13 | 1743.36 | 18 | 14.72 | 2872 | 761 | 2.21 / 404.65 | 2 | 2 |
5 | 13 | 1156.04 | 18 | 14.79 | 2061 | 549 | 2.76 / 405.20 | 2 | 3 |
6 | 13 | 579.76 | 18 | 14.93 | 1266 | 340 | 3.10 / 405.54 | 2 | 3 |
7 | 13 | 151.64 | 18 | 15.04 | 643 | 174 | 3.27 / 405.72 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.02 | 404 | 1001 | 4.27 / 406.72 | 2 | 9 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 27 | 14.97 | 558 | 226 | 0.23 / 398.52 | 2 | 2 |
2 | 12 | 1168.80 | 1 | 15.18 | 2134 | 32 | 0.26 / 398.55 | 2 | 2 |
3 | 7 | 2004.44 | 25 | 14.79 | 3204 | 1185 | 1.44 / 399.73 | 2 | 2 |
4 | 13 | 1620.72 | 18 | 14.73 | 2710 | 719 | 2.16 / 400.45 | 2 | 3 |
5 | 13 | 1070.72 | 18 | 14.81 | 1952 | 520 | 2.68 / 400.97 | 2 | 3 |
6 | 13 | 504.28 | 18 | 14.94 | 1157 | 311 | 2.99 / 401.28 | 2 | 3 |
7 | 13 | 122.40 | 18 | 15.04 | 601 | 163 | 3.16 / 401.44 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.01 | 404 | 1001 | 4.16 / 402.45 | 2 | 10 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 27 | 14.97 | 561 | 227 | 0.23 / 394.34 | 2 | 2 |
2 | 12 | 1328.76 | 1 | 15.12 | 2388 | 36 | 0.26 / 394.38 | 2 | 2 |
3 | 7 | 2003.00 | 25 | 14.78 | 3199 | 1182 | 1.44 / 395.56 | 2 | 2 |
4 | 13 | 1612.64 | 18 | 14.75 | 2693 | 715 | 2.16 / 396.28 | 2 | 2 |
5 | 13 | 1184.12 | 18 | 14.78 | 2107 | 561 | 2.72 / 396.84 | 2 | 3 |
6 | 13 | 459.12 | 18 | 14.94 | 1092 | 294 | 3.01 / 397.13 | 2 | 3 |
7 | 13 | 110.40 | 18 | 15.05 | 584 | 158 | 3.17 / 397.29 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.02 | 404 | 1001 | 4.17 / 398.29 | 2 | 6 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 27 | 14.96 | 563 | 227 | 0.23 / 390.15 | 2 | 2 |
2 | 12 | 1174.40 | 1 | 15.19 | 2146 | 33 | 0.26 / 390.18 | 2 | 2 |
3 | 7 | 2004.96 | 26 | 14.80 | 3201 | 1232 | 1.49 / 391.41 | 2 | 2 |
4 | 13 | 1737.96 | 18 | 14.73 | 2868 | 760 | 2.25 / 392.17 | 2 | 2 |
5 | 13 | 1011.88 | 18 | 14.83 | 1874 | 500 | 2.75 / 392.67 | 2 | 4 |
6 | 13 | 451.08 | 18 | 14.97 | 1085 | 292 | 3.04 / 392.97 | 2 | 4 |
7 | 13 | 108.24 | 18 | 15.05 | 582 | 158 | 3.20 / 393.12 | 2 | 5 |
8 | 8 | -0.04 | 165 | 15.02 | 400 | 991 | 4.19 / 394.12 | 2 | 9 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 27 | 14.98 | 542 | 219 | 0.22 / 385.89 | 2 | 2 |
2 | 12 | 1144.96 | 1 | 15.20 | 2108 | 32 | 0.25 / 385.93 | 2 | 2 |
3 | 7 | 2006.56 | 25 | 14.81 | 3199 | 1184 | 1.44 / 387.11 | 2 | 2 |
4 | 13 | 1743.32 | 18 | 14.73 | 2866 | 760 | 2.20 / 387.87 | 2 | 2 |
5 | 13 | 1153.88 | 18 | 14.80 | 2062 | 549 | 2.74 / 388.42 | 2 | 3 |
6 | 13 | 550.44 | 18 | 14.94 | 1222 | 329 | 3.07 / 388.75 | 2 | 4 |
7 | 13 | 137.64 | 18 | 15.05 | 622 | 168 | 3.24 / 388.92 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.02 | 406 | 1006 | 4.25 / 389.92 | 2 | 7 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 27 | 14.97 | 550 | 222 | 0.22 / 381.64 | 2 | 2 |
2 | 12 | 1138.80 | 1 | 15.19 | 2087 | 32 | 0.25 / 381.68 | 2 | 2 |
3 | 7 | 2008.60 | 25 | 14.82 | 3213 | 1190 | 1.44 / 382.87 | 2 | 2 |
4 | 13 | 1742.68 | 18 | 14.74 | 2873 | 762 | 2.21 / 383.63 | 2 | 2 |
5 | 13 | 1161.48 | 18 | 14.80 | 2078 | 554 | 2.76 / 384.18 | 2 | 2 |
6 | 13 | 574.24 | 18 | 14.94 | 1258 | 338 | 3.10 / 384.52 | 2 | 4 |
7 | 13 | 148.24 | 18 | 15.05 | 635 | 172 | 3.27 / 384.69 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.02 | 396 | 981 | 4.25 / 385.67 | 2 | 6 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 28 | 14.97 | 549 | 230 | 0.23 / 377.36 | 2 | 2 |
2 | 12 | 1164.16 | 1 | 15.19 | 2130 | 32 | 0.26 / 377.39 | 2 | 2 |
3 | 7 | 2008.12 | 25 | 14.83 | 3199 | 1186 | 1.45 / 378.58 | 2 | 2 |
4 | 13 | 1756.04 | 18 | 14.71 | 2894 | 766 | 2.21 / 379.35 | 2 | 2 |
5 | 13 | 1169.08 | 18 | 14.80 | 2088 | 556 | 2.77 / 379.90 | 2 | 2 |
6 | 13 | 597.32 | 18 | 14.93 | 1291 | 347 | 3.12 / 380.25 | 2 | 4 |
7 | 13 | 157.04 | 18 | 15.04 | 654 | 177 | 3.30 / 380.43 | 2 | 3 |
8 | 8 | 0.20 | 165 | 15.02 | 402 | 996 | 4.29 / 381.42 | 2 | 8 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 27 | 14.97 | 558 | 226 | 0.23 / 373.04 | 2 | 2 |
2 | 3 | 1021.76 | 1 | 15.04 | 1920 | 29 | 0.25 / 373.07 | 2 | 3 |
3 | 12 | 1175.32 | 1 | 15.19 | 2128 | 32 | 0.29 / 373.10 | 2 | 2 |
4 | 7 | 2009.00 | 26 | 14.80 | 3191 | 1228 | 1.51 / 374.33 | 2 | 2 |
5 | 13 | 1740.12 | 18 | 14.73 | 2856 | 757 | 2.27 / 375.08 | 2 | 2 |
6 | 13 | 1147.64 | 18 | 14.81 | 2047 | 546 | 2.82 / 375.63 | 2 | 3 |
7 | 13 | 679.32 | 18 | 14.90 | 1392 | 373 | 3.19 / 376.00 | 2 | 4 |
8 | 13 | 127.32 | 18 | 15.05 | 591 | 160 | 3.35 / 376.16 | 2 | 4 |
9 | 8 | 0.04 | 165 | 15.03 | 390 | 967 | 4.32 / 377.13 | 2 | 5 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 27 | 14.97 | 546 | 221 | 0.22 / 368.82 | 2 | 2 |
2 | 12 | 1157.24 | 1 | 15.20 | 2101 | 32 | 0.25 / 368.85 | 2 | 2 |
3 | 7 | 2005.16 | 25 | 14.82 | 3183 | 1179 | 1.43 / 370.03 | 2 | 2 |
4 | 13 | 1731.96 | 18 | 14.74 | 2842 | 754 | 2.19 / 370.79 | 2 | 2 |
5 | 13 | 1149.12 | 18 | 14.80 | 2043 | 544 | 2.73 / 371.33 | 2 | 3 |
6 | 13 | 564.44 | 18 | 14.93 | 1242 | 334 | 3.06 / 371.66 | 2 | 4 |
7 | 13 | 151.80 | 18 | 15.04 | 633 | 171 | 3.24 / 371.84 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.02 | 394 | 976 | 4.21 / 372.81 | 2 | 6 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 27 | 14.97 | 536 | 217 | 0.22 / 364.65 | 2 | 2 |
2 | 12 | 1163.52 | 1 | 15.19 | 2131 | 32 | 0.25 / 364.68 | 2 | 2 |
3 | 7 | 2013.00 | 25 | 14.83 | 3214 | 1192 | 1.44 / 365.88 | 2 | 2 |
4 | 13 | 1752.72 | 18 | 14.73 | 2877 | 763 | 2.20 / 366.64 | 2 | 2 |
5 | 13 | 1053.24 | 18 | 14.83 | 1917 | 512 | 2.72 / 367.15 | 2 | 3 |
6 | 13 | 509.96 | 18 | 14.96 | 1158 | 312 | 3.03 / 367.46 | 2 | 4 |
7 | 13 | 133.52 | 18 | 15.05 | 608 | 165 | 3.19 / 367.63 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.03 | 393 | 975 | 4.17 / 368.60 | 2 | 7 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 27 | 14.98 | 545 | 220 | 0.22 / 360.47 | 2 | 2 |
2 | 12 | 1174.96 | 1 | 15.19 | 2123 | 32 | 0.25 / 360.50 | 2 | 2 |
3 | 7 | 2008.52 | 25 | 14.82 | 3198 | 1185 | 1.44 / 361.68 | 2 | 2 |
4 | 13 | 1744.96 | 18 | 14.74 | 2874 | 763 | 2.20 / 362.44 | 2 | 3 |
5 | 13 | 1159.68 | 18 | 14.81 | 2054 | 548 | 2.75 / 362.99 | 2 | 3 |
6 | 13 | 468.72 | 18 | 14.97 | 1097 | 296 | 3.04 / 363.29 | 2 | 4 |
7 | 13 | 182.08 | 18 | 15.04 | 681 | 184 | 3.23 / 363.47 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.03 | 388 | 962 | 4.19 / 364.43 | 2 | 7 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 27 | 14.96 | 548 | 221 | 0.22 / 356.23 | 2 | 2 |
2 | 12 | 1171.40 | 1 | 15.19 | 2139 | 32 | 0.25 / 356.26 | 2 | 2 |
3 | 7 | 2003.52 | 26 | 14.83 | 3195 | 1232 | 1.49 / 357.50 | 2 | 2 |
4 | 13 | 1736.16 | 18 | 14.74 | 2850 | 756 | 2.24 / 358.25 | 2 | 2 |
5 | 13 | 1145.00 | 18 | 14.80 | 2042 | 544 | 2.79 / 358.80 | 2 | 3 |
6 | 13 | 556.12 | 18 | 14.93 | 1213 | 326 | 3.11 / 359.12 | 2 | 3 |
7 | 13 | 141.28 | 18 | 15.05 | 608 | 165 | 3.28 / 359.29 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.03 | 386 | 957 | 4.23 / 360.24 | 2 | 6 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 27 | 14.98 | 536 | 217 | 0.22 / 352.04 | 2 | 2 |
2 | 12 | 1160.32 | 1 | 15.19 | 2090 | 32 | 0.25 / 352.07 | 2 | 2 |
3 | 7 | 2003.08 | 25 | 14.82 | 3189 | 1182 | 1.43 / 353.25 | 2 | 2 |
4 | 13 | 1729.92 | 18 | 14.72 | 2851 | 755 | 2.19 / 354.01 | 2 | 2 |
5 | 13 | 1153.16 | 18 | 14.81 | 2055 | 548 | 2.73 / 354.55 | 2 | 3 |
6 | 13 | 569.64 | 18 | 14.93 | 1239 | 333 | 3.07 / 354.89 | 2 | 4 |
7 | 13 | 148.68 | 18 | 15.05 | 621 | 168 | 3.23 / 355.05 | 2 | 3 |
8 | 8 | 0.20 | 165 | 15.02 | 386 | 957 | 4.19 / 356.01 | 2 | 5 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 28 | 14.99 | 532 | 223 | 0.22 / 347.84 | 2 | 2 |
2 | 12 | 1295.04 | 1 | 15.16 | 2324 | 35 | 0.26 / 347.88 | 2 | 2 |
3 | 7 | 2007.52 | 25 | 14.84 | 3198 | 1186 | 1.44 / 349.06 | 2 | 2 |
4 | 13 | 1748.12 | 18 | 14.74 | 2877 | 763 | 2.21 / 349.83 | 2 | 2 |
5 | 13 | 1036.04 | 18 | 14.85 | 1893 | 506 | 2.71 / 350.33 | 2 | 4 |
6 | 13 | 608.00 | 18 | 14.94 | 1293 | 348 | 3.06 / 350.68 | 2 | 4 |
7 | 13 | 169.68 | 18 | 15.06 | 657 | 178 | 3.24 / 350.86 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.04 | 387 | 960 | 4.20 / 351.82 | 2 | 7 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.96 | 27 | 14.99 | 558 | 226 | 0.23 / 343.62 | 2 | 2 |
2 | 3 | 1029.84 | 1 | 15.04 | 1920 | 29 | 0.25 / 343.65 | 2 | 3 |
3 | 12 | 1164.88 | 1 | 15.21 | 2112 | 32 | 0.29 / 343.68 | 2 | 2 |
4 | 7 | 2006.00 | 25 | 14.84 | 3193 | 1185 | 1.47 / 344.86 | 2 | 2 |
5 | 13 | 1747.36 | 18 | 14.74 | 2875 | 763 | 2.23 / 345.63 | 2 | 2 |
6 | 13 | 1160.84 | 18 | 14.81 | 2064 | 550 | 2.78 / 346.18 | 2 | 3 |
7 | 13 | 566.24 | 18 | 14.95 | 1237 | 333 | 3.12 / 346.51 | 2 | 4 |
8 | 13 | 149.00 | 18 | 15.06 | 623 | 169 | 3.29 / 346.68 | 2 | 4 |
9 | 8 | 0.00 | 165 | 15.04 | 379 | 941 | 4.23 / 347.62 | 2 | 7 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 27 | 14.99 | 533 | 216 | 0.22 / 339.28 | 2 | 2 |
2 | 12 | 1167.08 | 1 | 15.20 | 2115 | 32 | 0.25 / 339.31 | 2 | 2 |
3 | 7 | 2006.32 | 26 | 14.81 | 3194 | 1230 | 1.48 / 340.54 | 2 | 2 |
4 | 13 | 1738.48 | 18 | 14.74 | 2859 | 759 | 2.24 / 341.30 | 2 | 2 |
5 | 13 | 1144.28 | 18 | 14.81 | 2037 | 543 | 2.78 / 341.84 | 2 | 3 |
6 | 13 | 547.56 | 18 | 14.96 | 1209 | 326 | 3.10 / 342.17 | 2 | 4 |
7 | 13 | 139.48 | 18 | 15.06 | 606 | 164 | 3.27 / 342.33 | 2 | 4 |
8 | 13 | 30.36 | 18 | 15.08 | 435 | 118 | 3.39 / 342.45 | 2 | 2 |
9 | 8 | 0.08 | 165 | 15.03 | 381 | 945 | 4.33 / 343.39 | 2 | 7 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 27 | 15.00 | 536 | 217 | 0.22 / 335.08 | 2 | 2 |
2 | 12 | 1164.36 | 1 | 15.23 | 2139 | 33 | 0.25 / 335.11 | 2 | 2 |
3 | 7 | 2004.72 | 25 | 14.86 | 3190 | 1185 | 1.43 / 336.30 | 2 | 2 |
4 | 13 | 1742.96 | 18 | 14.76 | 2858 | 759 | 2.19 / 337.06 | 2 | 3 |
5 | 13 | 1168.84 | 18 | 14.83 | 2078 | 555 | 2.75 / 337.61 | 2 | 3 |
6 | 13 | 567.72 | 18 | 14.97 | 1237 | 333 | 3.08 / 337.94 | 2 | 3 |
7 | 13 | 142.76 | 18 | 15.09 | 614 | 167 | 3.25 / 338.11 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.06 | 382 | 949 | 4.20 / 339.06 | 2 | 6 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 27 | 14.99 | 538 | 218 | 0.22 / 330.73 | 2 | 2 |
2 | 12 | 1329.28 | 1 | 15.17 | 2346 | 36 | 0.25 / 330.76 | 2 | 2 |
3 | 7 | 2007.72 | 25 | 14.86 | 3191 | 1185 | 1.44 / 331.95 | 2 | 2 |
4 | 13 | 1744.76 | 18 | 14.76 | 2856 | 759 | 2.20 / 332.71 | 2 | 2 |
5 | 13 | 1289.24 | 18 | 14.80 | 2250 | 599 | 2.80 / 333.31 | 2 | 3 |
6 | 13 | 535.92 | 18 | 14.97 | 1193 | 321 | 3.12 / 333.63 | 2 | 4 |
7 | 13 | 147.92 | 18 | 15.08 | 630 | 171 | 3.29 / 333.80 | 2 | 3 |
8 | 13 | 15.36 | 18 | 15.09 | 415 | 113 | 3.40 / 333.91 | 2 | 2 |
9 | 8 | 0.00 | 165 | 15.04 | 383 | 950 | 4.35 / 334.86 | 2 | 6 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 27 | 15.00 | 538 | 218 | 0.22 / 326.55 | 2 | 2 |
2 | 12 | 1318.36 | 1 | 15.16 | 2345 | 36 | 0.25 / 326.58 | 2 | 2 |
3 | 7 | 2008.08 | 25 | 14.82 | 3193 | 1183 | 1.44 / 327.77 | 2 | 2 |
4 | 13 | 1607.80 | 18 | 14.77 | 2682 | 713 | 2.15 / 328.48 | 2 | 3 |
5 | 13 | 1045.72 | 18 | 14.86 | 1906 | 510 | 2.66 / 328.99 | 2 | 2 |
6 | 13 | 477.24 | 18 | 14.98 | 1114 | 300 | 2.96 / 329.29 | 2 | 3 |
7 | 13 | 113.48 | 18 | 15.07 | 572 | 155 | 3.11 / 329.44 | 2 | 2 |
8 | 13 | 28.32 | 18 | 15.09 | 440 | 120 | 3.23 / 329.56 | 2 | 2 |
9 | 8 | 0.00 | 165 | 15.04 | 381 | 945 | 4.18 / 330.51 | 2 | 7 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 28 | 15.00 | 520 | 218 | 0.22 / 322.36 | 2 | 2 |
2 | 12 | 1146.56 | 1 | 15.23 | 2093 | 32 | 0.25 / 322.40 | 2 | 2 |
3 | 7 | 2004.00 | 25 | 14.85 | 3174 | 1178 | 1.43 / 323.57 | 2 | 2 |
4 | 13 | 1748.36 | 18 | 14.76 | 2862 | 760 | 2.19 / 324.34 | 2 | 2 |
5 | 13 | 1158.24 | 18 | 14.83 | 2055 | 549 | 2.74 / 324.88 | 2 | 3 |
6 | 13 | 558.80 | 18 | 14.97 | 1234 | 333 | 3.07 / 325.22 | 2 | 4 |
7 | 13 | 144.16 | 18 | 15.09 | 623 | 169 | 3.24 / 325.39 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.06 | 380 | 944 | 4.18 / 326.33 | 2 | 12 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 28 | 14.99 | 536 | 225 | 0.22 / 318.19 | 2 | 2 |
2 | 12 | 1295.92 | 1 | 15.18 | 2320 | 35 | 0.26 / 318.23 | 2 | 2 |
3 | 7 | 2003.88 | 25 | 14.83 | 3174 | 1177 | 1.44 / 319.40 | 2 | 2 |
4 | 13 | 1734.84 | 18 | 14.76 | 2850 | 757 | 2.19 / 320.16 | 2 | 3 |
5 | 13 | 1145.88 | 18 | 14.84 | 2044 | 546 | 2.74 / 320.71 | 2 | 2 |
6 | 13 | 563.12 | 18 | 14.96 | 1233 | 332 | 3.07 / 321.04 | 2 | 3 |
7 | 13 | 139.12 | 18 | 15.08 | 607 | 165 | 3.24 / 321.20 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.05 | 380 | 944 | 4.18 / 322.15 | 2 | 5 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 28 | 15.00 | 538 | 226 | 0.23 / 313.95 | 2 | 2 |
2 | 12 | 1170.20 | 1 | 15.22 | 2112 | 32 | 0.26 / 313.99 | 2 | 2 |
3 | 7 | 2004.68 | 25 | 14.87 | 3206 | 1192 | 1.45 / 315.18 | 2 | 2 |
4 | 13 | 1615.36 | 18 | 14.80 | 2703 | 720 | 2.17 / 315.90 | 2 | 2 |
5 | 13 | 1064.28 | 18 | 14.86 | 1940 | 519 | 2.69 / 316.42 | 2 | 4 |
6 | 13 | 510.88 | 18 | 14.99 | 1167 | 315 | 3.00 / 316.73 | 2 | 4 |
7 | 13 | 127.60 | 18 | 15.09 | 596 | 162 | 3.17 / 316.89 | 2 | 3 |
8 | 13 | 30.36 | 18 | 15.10 | 442 | 120 | 3.29 / 317.01 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.06 | 383 | 952 | 4.24 / 317.97 | 2 | 10 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 27 | 15.00 | 526 | 213 | 0.21 / 309.69 | 2 | 2 |
2 | 3 | 1017.24 | 1 | 15.08 | 1918 | 29 | 0.24 / 309.72 | 2 | 2 |
3 | 12 | 1166.36 | 1 | 15.23 | 2111 | 32 | 0.27 / 309.75 | 2 | 2 |
4 | 7 | 2005.92 | 26 | 14.84 | 3183 | 1228 | 1.50 / 310.98 | 2 | 2 |
5 | 13 | 1616.12 | 18 | 14.78 | 2687 | 715 | 2.22 / 311.69 | 2 | 2 |
6 | 13 | 1043.60 | 18 | 14.86 | 1895 | 507 | 2.72 / 312.20 | 2 | 3 |
7 | 13 | 479.80 | 18 | 14.99 | 1116 | 301 | 3.03 / 312.50 | 2 | 4 |
8 | 13 | 114.20 | 18 | 15.08 | 578 | 157 | 3.18 / 312.66 | 2 | 3 |
9 | 13 | 26.08 | 18 | 15.10 | 436 | 119 | 3.30 / 312.78 | 2 | 3 |
10 | 8 | 0.00 | 165 | 15.05 | 383 | 951 | 4.25 / 313.73 | 2 | 8 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 28 | 15.01 | 519 | 218 | 0.22 / 305.36 | 2 | 2 |
2 | 12 | 1162.40 | 1 | 15.25 | 2090 | 32 | 0.25 / 305.39 | 2 | 2 |
3 | 7 | 2006.08 | 26 | 14.83 | 3188 | 1229 | 1.48 / 306.62 | 2 | 2 |
4 | 13 | 1738.12 | 18 | 14.77 | 2866 | 762 | 2.24 / 307.38 | 2 | 2 |
5 | 13 | 1163.56 | 18 | 14.83 | 2063 | 551 | 2.79 / 307.93 | 2 | 2 |
6 | 13 | 555.80 | 18 | 14.98 | 1214 | 327 | 3.12 / 308.26 | 2 | 4 |
7 | 13 | 136.24 | 18 | 15.09 | 602 | 164 | 3.28 / 308.42 | 2 | 3 |
8 | 13 | 29.72 | 18 | 15.11 | 436 | 119 | 3.40 / 308.54 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.06 | 377 | 937 | 4.34 / 309.48 | 2 | 9 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 28 | 15.01 | 530 | 223 | 0.22 / 301.06 | 2 | 2 |
2 | 12 | 1166.72 | 1 | 15.22 | 2104 | 32 | 0.25 / 301.09 | 2 | 2 |
3 | 7 | 2002.96 | 25 | 14.85 | 3176 | 1179 | 1.43 / 302.27 | 2 | 2 |
4 | 13 | 1747.12 | 18 | 14.76 | 2861 | 760 | 2.19 / 303.03 | 2 | 2 |
5 | 13 | 1167.32 | 18 | 14.84 | 2065 | 552 | 2.75 / 303.58 | 2 | 3 |
6 | 13 | 580.04 | 18 | 14.96 | 1253 | 337 | 3.08 / 303.92 | 2 | 4 |
7 | 13 | 145.84 | 18 | 15.09 | 615 | 167 | 3.25 / 304.09 | 2 | 3 |
8 | 13 | 31.96 | 18 | 15.10 | 438 | 119 | 3.37 / 304.20 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.06 | 376 | 934 | 4.30 / 305.14 | 2 | 9 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 28 | 15.01 | 520 | 219 | 0.22 / 296.75 | 2 | 2 |
2 | 12 | 1327.88 | 1 | 15.18 | 2339 | 36 | 0.25 / 296.79 | 2 | 2 |
3 | 7 | 2003.60 | 25 | 14.83 | 3189 | 1182 | 1.44 / 297.97 | 2 | 2 |
4 | 13 | 1743.04 | 18 | 14.76 | 2862 | 760 | 2.20 / 298.73 | 2 | 2 |
5 | 13 | 1154.04 | 18 | 14.83 | 2066 | 551 | 2.75 / 299.28 | 2 | 3 |
6 | 13 | 566.56 | 18 | 14.98 | 1237 | 334 | 3.08 / 299.61 | 2 | 4 |
7 | 13 | 147.64 | 18 | 15.09 | 622 | 169 | 3.25 / 299.78 | 2 | 3 |
8 | 13 | 32.32 | 18 | 15.11 | 440 | 120 | 3.37 / 299.90 | 2 | 3 |
9 | 8 | 0.00 | 165 | 15.06 | 375 | 932 | 4.30 / 300.84 | 2 | 8 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 27 | 15.02 | 523 | 212 | 0.21 / 292.46 | 2 | 2 |
2 | 12 | 1167.80 | 1 | 15.22 | 2118 | 32 | 0.24 / 292.49 | 2 | 2 |
3 | 7 | 2009.12 | 25 | 14.85 | 3172 | 1178 | 1.42 / 293.67 | 2 | 2 |
4 | 13 | 1744.76 | 18 | 14.77 | 2867 | 762 | 2.18 / 294.43 | 2 | 2 |
5 | 13 | 1172.80 | 18 | 14.84 | 2068 | 552 | 2.74 / 294.98 | 2 | 3 |
6 | 13 | 567.48 | 18 | 14.98 | 1243 | 335 | 3.07 / 295.32 | 2 | 4 |
7 | 13 | 143.72 | 18 | 15.10 | 613 | 167 | 3.24 / 295.48 | 2 | 3 |
8 | 13 | 31.88 | 18 | 15.11 | 437 | 119 | 3.36 / 295.60 | 2 | 3 |
9 | 8 | 0.00 | 165 | 15.06 | 375 | 932 | 4.29 / 296.53 | 2 | 8 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 27 | 15.03 | 522 | 212 | 0.21 / 288.36 | 2 | 2 |
2 | 12 | 1176.64 | 1 | 15.22 | 2125 | 32 | 0.24 / 288.39 | 2 | 2 |
3 | 7 | 2011.40 | 25 | 14.86 | 3188 | 1184 | 1.43 / 289.57 | 2 | 2 |
4 | 13 | 1755.28 | 18 | 14.77 | 2863 | 761 | 2.19 / 290.34 | 2 | 2 |
5 | 13 | 1050.48 | 18 | 14.88 | 1902 | 509 | 2.70 / 290.85 | 2 | 3 |
6 | 13 | 504.76 | 18 | 15.01 | 1141 | 308 | 3.01 / 291.15 | 2 | 4 |
7 | 13 | 130.96 | 18 | 15.10 | 590 | 160 | 3.17 / 291.31 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.07 | 374 | 930 | 4.10 / 292.24 | 2 | 7 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 27 | 15.04 | 524 | 213 | 0.21 / 284.21 | 2 | 2 |
2 | 12 | 1325.40 | 1 | 15.19 | 2356 | 36 | 0.25 / 284.24 | 2 | 2 |
3 | 7 | 2004.24 | 25 | 14.84 | 3177 | 1179 | 1.43 / 285.42 | 2 | 2 |
4 | 13 | 1737.60 | 18 | 14.76 | 2846 | 756 | 2.18 / 286.18 | 2 | 2 |
5 | 13 | 1155.76 | 18 | 14.85 | 2048 | 547 | 2.73 / 286.73 | 2 | 2 |
6 | 13 | 556.68 | 18 | 15.00 | 1213 | 328 | 3.06 / 287.05 | 2 | 4 |
7 | 13 | 137.04 | 18 | 15.11 | 598 | 163 | 3.22 / 287.22 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.07 | 374 | 930 | 4.15 / 288.15 | 2 | 7 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 27 | 15.04 | 512 | 208 | 0.21 / 280.03 | 2 | 2 |
2 | 12 | 1167.92 | 1 | 15.23 | 2106 | 32 | 0.24 / 280.06 | 2 | 2 |
3 | 7 | 2006.52 | 25 | 14.87 | 3170 | 1178 | 1.42 / 281.24 | 2 | 2 |
4 | 13 | 1748.80 | 18 | 14.78 | 2867 | 763 | 2.18 / 282.00 | 2 | 2 |
5 | 13 | 1173.96 | 18 | 14.86 | 2082 | 557 | 2.74 / 282.56 | 2 | 3 |
6 | 13 | 580.00 | 18 | 14.99 | 1258 | 339 | 3.08 / 282.90 | 2 | 3 |
7 | 13 | 144.52 | 18 | 15.10 | 616 | 167 | 3.24 / 283.07 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.09 | 373 | 929 | 4.17 / 284.00 | 2 | 5 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 27 | 15.05 | 519 | 211 | 0.21 / 275.91 | 2 | 2 |
2 | 12 | 1328.92 | 1 | 15.19 | 2345 | 36 | 0.25 / 275.94 | 2 | 2 |
3 | 7 | 2002.08 | 25 | 14.84 | 3175 | 1178 | 1.42 / 277.12 | 2 | 2 |
4 | 13 | 1721.96 | 18 | 14.79 | 2816 | 750 | 2.17 / 277.87 | 2 | 2 |
5 | 13 | 1139.12 | 18 | 14.86 | 2026 | 542 | 2.72 / 278.41 | 2 | 2 |
6 | 13 | 547.64 | 18 | 15.01 | 1202 | 325 | 3.04 / 278.74 | 2 | 5 |
7 | 13 | 141.16 | 18 | 15.12 | 602 | 164 | 3.20 / 278.90 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.10 | 370 | 922 | 4.13 / 279.82 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 27 | 15.04 | 521 | 212 | 0.21 / 271.78 | 2 | 2 |
2 | 12 | 1155.52 | 1 | 15.24 | 2089 | 32 | 0.24 / 271.81 | 2 | 2 |
3 | 7 | 2004.92 | 25 | 14.84 | 3168 | 1175 | 1.42 / 272.99 | 2 | 2 |
4 | 13 | 1733.64 | 18 | 14.77 | 2833 | 753 | 2.17 / 273.74 | 2 | 3 |
5 | 13 | 1142.68 | 18 | 14.87 | 2042 | 547 | 2.72 / 274.29 | 2 | 3 |
6 | 13 | 542.88 | 18 | 15.01 | 1195 | 323 | 3.04 / 274.61 | 2 | 4 |
7 | 13 | 135.64 | 18 | 15.12 | 595 | 162 | 3.20 / 274.77 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.10 | 370 | 922 | 4.13 / 275.70 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 27 | 15.06 | 529 | 215 | 0.22 / 267.62 | 2 | 2 |
2 | 12 | 1318.96 | 1 | 15.20 | 2332 | 35 | 0.25 / 267.65 | 2 | 2 |
3 | 7 | 2008.28 | 25 | 14.88 | 3184 | 1184 | 1.43 / 268.83 | 2 | 2 |
4 | 13 | 1748.36 | 18 | 14.79 | 2866 | 763 | 2.20 / 269.60 | 2 | 2 |
5 | 13 | 1159.92 | 18 | 14.87 | 2050 | 549 | 2.75 / 270.15 | 2 | 3 |
6 | 13 | 579.52 | 18 | 15.01 | 1247 | 337 | 3.08 / 270.48 | 2 | 3 |
7 | 13 | 153.60 | 18 | 15.12 | 623 | 170 | 3.25 / 270.65 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.10 | 368 | 917 | 4.17 / 271.57 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 27 | 15.06 | 527 | 214 | 0.21 / 263.49 | 2 | 2 |
2 | 12 | 1155.52 | 1 | 15.24 | 2066 | 31 | 0.25 / 263.52 | 2 | 2 |
3 | 7 | 2011.76 | 25 | 14.89 | 3182 | 1184 | 1.43 / 264.70 | 2 | 2 |
4 | 13 | 1622.72 | 18 | 14.79 | 2710 | 721 | 2.15 / 265.42 | 2 | 2 |
5 | 13 | 1180.96 | 18 | 14.85 | 2097 | 561 | 2.71 / 265.98 | 2 | 2 |
6 | 13 | 571.20 | 18 | 15.01 | 1237 | 334 | 3.05 / 266.32 | 2 | 3 |
7 | 13 | 149.00 | 18 | 15.12 | 615 | 167 | 3.21 / 266.48 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.11 | 367 | 915 | 4.13 / 267.40 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 27 | 15.07 | 510 | 208 | 0.21 / 259.41 | 2 | 2 |
2 | 12 | 1150.44 | 1 | 15.25 | 2066 | 32 | 0.24 / 259.44 | 2 | 2 |
3 | 7 | 2005.24 | 25 | 14.89 | 3185 | 1186 | 1.42 / 260.63 | 2 | 2 |
4 | 13 | 1742.68 | 18 | 14.80 | 2852 | 760 | 2.18 / 261.38 | 2 | 2 |
5 | 13 | 1040.88 | 18 | 14.91 | 1893 | 508 | 2.69 / 261.89 | 2 | 3 |
6 | 13 | 489.32 | 18 | 15.04 | 1126 | 305 | 3.00 / 262.20 | 2 | 3 |
7 | 13 | 126.00 | 18 | 15.14 | 579 | 158 | 3.16 / 262.36 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.12 | 367 | 916 | 4.07 / 263.27 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 27 | 15.05 | 526 | 214 | 0.21 / 255.36 | 2 | 2 |
2 | 3 | 1016.08 | 1 | 15.10 | 1866 | 28 | 0.24 / 255.39 | 2 | 2 |
3 | 12 | 1324.72 | 1 | 15.20 | 2335 | 35 | 0.28 / 255.42 | 2 | 2 |
4 | 7 | 2006.64 | 25 | 14.86 | 3180 | 1181 | 1.46 / 256.61 | 2 | 2 |
5 | 13 | 1610.84 | 18 | 14.81 | 2689 | 717 | 2.18 / 257.32 | 2 | 2 |
6 | 13 | 1061.52 | 18 | 14.89 | 1915 | 513 | 2.69 / 257.84 | 2 | 3 |
7 | 13 | 490.12 | 18 | 15.03 | 1120 | 303 | 2.99 / 258.14 | 2 | 4 |
8 | 13 | 118.40 | 18 | 15.13 | 567 | 154 | 3.15 / 258.29 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.11 | 364 | 908 | 4.05 / 259.20 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 27 | 15.07 | 523 | 213 | 0.21 / 251.27 | 2 | 2 |
2 | 12 | 1164.12 | 1 | 15.23 | 2072 | 32 | 0.24 / 251.30 | 2 | 2 |
3 | 7 | 2003.44 | 25 | 14.84 | 3156 | 1171 | 1.42 / 252.47 | 2 | 2 |
4 | 13 | 1603.44 | 18 | 14.80 | 2658 | 708 | 2.12 / 253.18 | 2 | 3 |
5 | 13 | 1175.16 | 18 | 14.85 | 2074 | 554 | 2.68 / 253.73 | 2 | 3 |
6 | 13 | 573.92 | 18 | 14.99 | 1237 | 334 | 3.01 / 254.07 | 2 | 4 |
7 | 13 | 142.32 | 18 | 15.12 | 603 | 164 | 3.18 / 254.23 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.10 | 367 | 914 | 4.09 / 255.15 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 27 | 15.09 | 515 | 210 | 0.21 / 247.11 | 2 | 2 |
2 | 12 | 1171.24 | 1 | 15.25 | 2103 | 32 | 0.24 / 247.14 | 2 | 2 |
3 | 7 | 2007.40 | 25 | 14.89 | 3186 | 1186 | 1.43 / 248.33 | 2 | 2 |
4 | 13 | 1746.64 | 18 | 14.80 | 2857 | 761 | 2.19 / 249.09 | 2 | 2 |
5 | 13 | 1158.60 | 18 | 14.88 | 2055 | 550 | 2.74 / 249.64 | 2 | 2 |
6 | 13 | 563.00 | 18 | 15.03 | 1229 | 332 | 3.07 / 249.97 | 2 | 4 |
7 | 13 | 150.92 | 18 | 15.15 | 616 | 168 | 3.24 / 250.14 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.13 | 367 | 916 | 4.16 / 251.06 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 26 | 15.08 | 520 | 204 | 0.20 / 243.01 | 2 | 2 |
2 | 12 | 1176.56 | 1 | 15.26 | 2107 | 32 | 0.24 / 243.04 | 2 | 2 |
3 | 7 | 2004.04 | 25 | 14.86 | 3174 | 1179 | 1.42 / 244.22 | 2 | 2 |
4 | 13 | 1729.40 | 18 | 14.80 | 2826 | 753 | 2.17 / 244.97 | 2 | 2 |
5 | 13 | 1120.40 | 18 | 14.89 | 1993 | 534 | 2.70 / 245.51 | 2 | 3 |
6 | 13 | 529.44 | 18 | 15.05 | 1179 | 319 | 3.02 / 245.83 | 2 | 3 |
7 | 13 | 128.84 | 18 | 15.16 | 587 | 160 | 3.18 / 245.99 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.14 | 366 | 914 | 4.10 / 246.90 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 27 | 15.08 | 522 | 213 | 0.21 / 238.97 | 2 | 2 |
2 | 12 | 1302.40 | 1 | 15.20 | 2324 | 35 | 0.25 / 239.01 | 2 | 2 |
3 | 7 | 2004.00 | 26 | 14.87 | 3164 | 1223 | 1.47 / 240.23 | 2 | 2 |
4 | 13 | 1602.48 | 18 | 14.82 | 2658 | 709 | 2.18 / 240.94 | 2 | 2 |
5 | 13 | 1054.72 | 18 | 14.91 | 1905 | 511 | 2.69 / 241.45 | 2 | 3 |
6 | 13 | 481.28 | 18 | 15.06 | 1102 | 299 | 2.99 / 241.75 | 2 | 3 |
7 | 13 | 120.40 | 18 | 15.16 | 565 | 154 | 3.14 / 241.90 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.14 | 361 | 902 | 4.05 / 242.80 | 2 | 7 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 26 | 15.08 | 531 | 208 | 0.21 / 234.79 | 2 | 2 |
2 | 10 | 1007.00 | 2 | 15.06 | 1859 | 56 | 0.26 / 234.84 | 2 | 2 |
3 | 3 | 953.80 | -1 | 15.46 | 0 | 0 | 0.06 / 234.84 | 2 | 2 |
4 | 12 | 1150.20 | 1 | 15.24 | 2073 | 32 | 0.30 / 234.87 | 2 | 2 |
5 | 7 | 2002.48 | 26 | 14.86 | 3160 | 1221 | 1.52 / 236.09 | 2 | 2 |
6 | 13 | 1732.32 | 18 | 14.79 | 2831 | 754 | 2.27 / 236.85 | 2 | 2 |
7 | 13 | 1141.60 | 18 | 14.88 | 2030 | 544 | 2.81 / 237.39 | 2 | 3 |
8 | 13 | 441.52 | 18 | 15.07 | 1047 | 284 | 3.10 / 237.68 | 2 | 3 |
9 | 13 | 160.64 | 18 | 15.14 | 631 | 172 | 3.27 / 237.85 | 2 | 3 |
10 | 8 | 0.04 | 165 | 15.13 | 365 | 911 | 4.18 / 238.76 | 2 | 7 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 26 | 15.09 | 518 | 203 | 0.20 / 230.66 | 2 | 2 |
2 | 12 | 1170.44 | 1 | 15.24 | 2097 | 32 | 0.24 / 230.69 | 2 | 2 |
3 | 7 | 2003.48 | 25 | 14.88 | 3173 | 1180 | 1.42 / 231.87 | 2 | 2 |
4 | 13 | 1735.88 | 18 | 14.79 | 2836 | 755 | 2.17 / 232.62 | 2 | 2 |
5 | 13 | 1169.68 | 18 | 14.88 | 2055 | 550 | 2.72 / 233.17 | 2 | 2 |
6 | 13 | 582.16 | 18 | 15.04 | 1240 | 336 | 3.06 / 233.51 | 2 | 4 |
7 | 13 | 148.32 | 18 | 15.15 | 607 | 166 | 3.22 / 233.68 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.14 | 361 | 902 | 4.12 / 234.58 | 2 | 8 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 26 | 15.10 | 523 | 205 | 0.21 / 226.50 | 2 | 2 |
2 | 12 | 1170.92 | 1 | 15.26 | 2102 | 32 | 0.24 / 226.54 | 2 | 2 |
3 | 7 | 2004.68 | 26 | 14.86 | 3177 | 1227 | 1.46 / 227.76 | 2 | 2 |
4 | 13 | 1737.96 | 18 | 14.79 | 2852 | 759 | 2.22 / 228.52 | 2 | 2 |
5 | 13 | 1138.36 | 18 | 14.89 | 2019 | 541 | 2.77 / 229.06 | 2 | 3 |
6 | 13 | 544.04 | 18 | 15.05 | 1193 | 323 | 3.09 / 229.39 | 2 | 3 |
7 | 13 | 133.08 | 18 | 15.15 | 585 | 160 | 3.25 / 229.55 | 2 | 3 |
8 | 8 | 0.24 | 165 | 15.14 | 363 | 907 | 4.15 / 230.45 | 2 | 3 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 26 | 15.11 | 520 | 204 | 0.20 / 222.39 | 2 | 2 |
2 | 12 | 1165.80 | 1 | 15.26 | 2093 | 32 | 0.24 / 222.42 | 2 | 2 |
3 | 7 | 2011.24 | 25 | 14.89 | 3182 | 1184 | 1.42 / 223.61 | 2 | 2 |
4 | 13 | 1612.32 | 18 | 14.82 | 2680 | 715 | 2.14 / 224.32 | 2 | 2 |
5 | 13 | 1171.80 | 18 | 14.89 | 2073 | 556 | 2.69 / 224.88 | 2 | 3 |
6 | 13 | 578.40 | 18 | 15.04 | 1240 | 336 | 3.03 / 225.21 | 2 | 3 |
7 | 13 | 148.48 | 18 | 15.17 | 618 | 169 | 3.20 / 225.38 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.15 | 366 | 915 | 4.11 / 226.30 | 2 | 4 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 26 | 15.10 | 517 | 203 | 0.20 / 218.19 | 2 | 2 |
2 | 3 | 1016.60 | 1 | 15.14 | 1902 | 29 | 0.23 / 218.21 | 2 | 3 |
3 | 12 | 1164.48 | 1 | 15.27 | 2084 | 32 | 0.26 / 218.25 | 2 | 2 |
4 | 7 | 2005.68 | 26 | 14.88 | 3171 | 1227 | 1.49 / 219.47 | 2 | 2 |
5 | 13 | 1741.28 | 18 | 14.80 | 2845 | 758 | 2.25 / 220.23 | 2 | 2 |
6 | 13 | 1161.44 | 18 | 14.90 | 2058 | 552 | 2.80 / 220.78 | 2 | 2 |
7 | 13 | 552.92 | 18 | 15.05 | 1206 | 327 | 3.13 / 221.11 | 2 | 3 |
8 | 13 | 145.88 | 18 | 15.17 | 609 | 166 | 3.29 / 221.28 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.15 | 365 | 912 | 4.21 / 222.19 | 2 | 6 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 27 | 15.10 | 515 | 210 | 0.21 / 214.04 | 2 | 2 |
2 | 3 | 972.56 | -1 | 15.50 | 0 | 0 | 0.00 / 214.04 | 2 | 2 |
3 | 12 | 1178.12 | 1 | 15.27 | 2108 | 32 | 0.24 / 214.07 | 2 | 2 |
4 | 7 | 2007.72 | 25 | 14.91 | 3166 | 1180 | 1.42 / 215.25 | 2 | 2 |
5 | 13 | 1757.84 | 18 | 14.81 | 2872 | 766 | 2.19 / 216.02 | 2 | 2 |
6 | 13 | 1163.96 | 18 | 14.89 | 2064 | 553 | 2.74 / 216.57 | 2 | 3 |
7 | 13 | 570.92 | 18 | 15.06 | 1227 | 333 | 3.07 / 216.91 | 2 | 3 |
8 | 13 | 142.12 | 18 | 15.18 | 600 | 164 | 3.24 / 217.07 | 2 | 3 |
9 | 8 | 0.24 | 165 | 15.15 | 365 | 912 | 4.15 / 217.98 | 2 | 6 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 26 | 15.12 | 530 | 208 | 0.21 / 209.90 | 2 | 2 |
2 | 3 | 1043.56 | 1 | 15.11 | 1921 | 29 | 0.24 / 209.93 | 2 | 2 |
3 | 12 | 1170.00 | 1 | 15.26 | 2100 | 32 | 0.27 / 209.96 | 2 | 2 |
4 | 7 | 2005.44 | 25 | 14.87 | 3160 | 1175 | 1.44 / 211.14 | 2 | 3 |
5 | 13 | 1728.92 | 18 | 14.81 | 2825 | 753 | 2.20 / 211.89 | 2 | 2 |
6 | 13 | 1150.64 | 18 | 14.91 | 2034 | 546 | 2.74 / 212.44 | 2 | 3 |
7 | 13 | 555.96 | 18 | 15.06 | 1210 | 328 | 3.07 / 212.77 | 2 | 3 |
8 | 13 | 138.92 | 18 | 15.19 | 590 | 161 | 3.23 / 212.93 | 2 | 2 |
9 | 8 | 0.08 | 165 | 15.16 | 362 | 906 | 4.14 / 213.83 | 2 | 7 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 26 | 15.12 | 508 | 200 | 0.20 / 205.81 | 2 | 2 |
2 | 12 | 1319.60 | 1 | 15.23 | 2305 | 35 | 0.23 / 205.85 | 2 | 2 |
3 | 7 | 2007.36 | 25 | 14.87 | 3162 | 1175 | 1.41 / 207.02 | 2 | 2 |
4 | 13 | 1749.80 | 18 | 14.81 | 2855 | 761 | 2.17 / 207.78 | 2 | 2 |
5 | 13 | 1032.88 | 18 | 14.95 | 1873 | 504 | 2.68 / 208.29 | 2 | 3 |
6 | 13 | 591.16 | 18 | 15.05 | 1256 | 340 | 3.02 / 208.63 | 2 | 3 |
7 | 13 | 146.88 | 18 | 15.19 | 604 | 165 | 3.18 / 208.79 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.16 | 361 | 903 | 4.08 / 209.69 | 2 | 8 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 27 | 15.12 | 514 | 210 | 0.21 / 201.62 | 2 | 2 |
2 | 3 | 969.28 | -1 | 15.50 | 0 | 0 | 0.00 / 201.62 | 2 | 2 |
3 | 12 | 1311.68 | 1 | 15.23 | 2287 | 35 | 0.24 / 201.66 | 2 | 2 |
4 | 7 | 2004.00 | 25 | 14.91 | 3178 | 1185 | 1.43 / 202.84 | 2 | 2 |
5 | 13 | 1874.32 | 18 | 14.79 | 3009 | 801 | 2.23 / 203.64 | 2 | 2 |
6 | 13 | 1258.48 | 18 | 14.89 | 2185 | 586 | 2.82 / 204.23 | 2 | 3 |
7 | 13 | 529.04 | 18 | 15.08 | 1165 | 316 | 3.13 / 204.54 | 2 | 3 |
8 | 13 | 138.60 | 18 | 15.19 | 591 | 162 | 3.29 / 204.70 | 2 | 2 |
9 | 8 | 0.12 | 165 | 15.17 | 362 | 906 | 4.20 / 205.61 | 2 | 7 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 27 | 15.09 | 513 | 209 | 0.21 / 197.56 | 2 | 2 |
2 | 12 | 1152.80 | 1 | 15.30 | 2065 | 32 | 0.24 / 197.59 | 2 | 2 |
3 | 7 | 2004.68 | 25 | 14.90 | 3181 | 1185 | 1.43 / 198.77 | 2 | 2 |
4 | 13 | 1733.52 | 18 | 14.82 | 2828 | 754 | 2.18 / 199.53 | 2 | 2 |
5 | 13 | 1160.44 | 18 | 14.92 | 2051 | 551 | 2.73 / 200.08 | 2 | 2 |
6 | 13 | 459.56 | 18 | 15.10 | 1068 | 290 | 3.02 / 200.37 | 2 | 3 |
7 | 13 | 116.76 | 18 | 15.19 | 556 | 152 | 3.17 / 200.52 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.17 | 356 | 891 | 4.06 / 201.41 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 27 | 15.10 | 507 | 207 | 0.21 / 193.35 | 2 | 2 |
2 | 3 | 1016.08 | 1 | 15.15 | 1867 | 28 | 0.23 / 193.38 | 2 | 2 |
3 | 12 | 1158.60 | 1 | 15.27 | 2066 | 32 | 0.27 / 193.41 | 2 | 2 |
4 | 7 | 2005.96 | 25 | 14.87 | 3171 | 1179 | 1.45 / 194.59 | 2 | 2 |
5 | 13 | 1741.32 | 18 | 14.80 | 2855 | 761 | 2.21 / 195.35 | 2 | 2 |
6 | 13 | 1147.64 | 18 | 14.91 | 2033 | 546 | 2.75 / 195.89 | 2 | 3 |
7 | 13 | 451.16 | 18 | 15.09 | 1054 | 286 | 3.04 / 196.18 | 2 | 2 |
8 | 13 | 166.80 | 18 | 15.16 | 634 | 173 | 3.21 / 196.35 | 2 | 3 |
9 | 13 | 15.56 | 18 | 15.19 | 393 | 107 | 3.32 / 196.46 | 2 | 3 |
10 | 8 | -0.04 | 165 | 15.15 | 355 | 887 | 4.21 / 197.35 | 2 | 8 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 27 | 15.14 | 493 | 202 | 0.20 / 189.26 | 2 | 2 |
2 | 12 | 1163.64 | 1 | 15.25 | 2067 | 32 | 0.23 / 189.29 | 2 | 2 |
3 | 7 | 2003.88 | 25 | 14.90 | 3165 | 1179 | 1.41 / 190.47 | 2 | 2 |
4 | 13 | 1616.96 | 18 | 14.81 | 2673 | 713 | 2.12 / 191.18 | 2 | 2 |
5 | 13 | 1075.00 | 18 | 14.92 | 1924 | 517 | 2.64 / 191.70 | 2 | 3 |
6 | 13 | 506.96 | 18 | 15.08 | 1134 | 308 | 2.95 / 192.01 | 2 | 3 |
7 | 13 | 126.44 | 18 | 15.17 | 562 | 153 | 3.10 / 192.16 | 2 | 3 |
8 | 13 | 25.28 | 18 | 15.19 | 401 | 110 | 3.21 / 192.27 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.15 | 349 | 872 | 4.08 / 193.14 | 2 | 11 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 27 | 15.13 | 502 | 205 | 0.21 / 185.19 | 2 | 2 |
2 | 12 | 1169.68 | 1 | 15.29 | 2078 | 32 | 0.24 / 185.22 | 2 | 2 |
3 | 7 | 2003.16 | 25 | 14.91 | 3180 | 1185 | 1.42 / 186.40 | 2 | 2 |
4 | 13 | 1738.68 | 18 | 14.82 | 2844 | 759 | 2.18 / 187.16 | 2 | 2 |
5 | 13 | 1039.20 | 18 | 14.96 | 1885 | 508 | 2.69 / 187.67 | 2 | 3 |
6 | 13 | 599.80 | 18 | 15.08 | 1267 | 344 | 3.03 / 188.01 | 2 | 3 |
7 | 13 | 152.12 | 18 | 15.19 | 607 | 166 | 3.20 / 188.18 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.18 | 350 | 877 | 4.07 / 189.06 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 27 | 15.12 | 503 | 205 | 0.21 / 181.22 | 2 | 2 |
2 | 12 | 1172.08 | 1 | 15.28 | 2097 | 32 | 0.24 / 181.25 | 2 | 2 |
3 | 7 | 2011.32 | 25 | 14.89 | 3169 | 1180 | 1.42 / 182.43 | 2 | 2 |
4 | 13 | 1621.88 | 18 | 14.85 | 2674 | 715 | 2.13 / 183.14 | 2 | 2 |
5 | 13 | 1058.08 | 18 | 14.95 | 1907 | 513 | 2.64 / 183.66 | 2 | 3 |
6 | 13 | 480.84 | 18 | 15.11 | 1093 | 297 | 2.94 / 183.95 | 2 | 4 |
7 | 13 | 114.04 | 18 | 15.20 | 542 | 148 | 3.09 / 184.10 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.18 | 351 | 879 | 3.97 / 184.98 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 27 | 15.13 | 506 | 207 | 0.21 / 177.20 | 2 | 2 |
2 | 12 | 1145.36 | 1 | 15.29 | 2031 | 31 | 0.24 / 177.23 | 2 | 2 |
3 | 7 | 2005.24 | 25 | 14.89 | 3167 | 1179 | 1.42 / 178.41 | 2 | 2 |
4 | 13 | 1608.28 | 18 | 14.85 | 2664 | 712 | 2.13 / 179.12 | 2 | 3 |
5 | 13 | 1185.48 | 18 | 14.91 | 2079 | 558 | 2.69 / 179.68 | 2 | 3 |
6 | 13 | 454.96 | 18 | 15.11 | 1057 | 287 | 2.97 / 179.96 | 2 | 3 |
7 | 13 | 163.88 | 18 | 15.19 | 625 | 171 | 3.15 / 180.13 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.18 | 350 | 877 | 4.02 / 181.01 | 2 | 4 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 27 | 15.14 | 498 | 204 | 0.20 / 173.16 | 2 | 2 |
2 | 12 | 1155.72 | 1 | 15.30 | 2069 | 32 | 0.24 / 173.19 | 2 | 2 |
3 | 7 | 2004.44 | 25 | 14.90 | 3168 | 1180 | 1.42 / 174.37 | 2 | 3 |
4 | 13 | 1741.04 | 18 | 14.83 | 2843 | 759 | 2.17 / 175.13 | 2 | 2 |
5 | 13 | 1022.20 | 18 | 14.98 | 1864 | 503 | 2.68 / 175.64 | 2 | 3 |
6 | 13 | 471.48 | 18 | 15.13 | 1084 | 295 | 2.97 / 175.93 | 2 | 3 |
7 | 13 | 175.16 | 18 | 15.19 | 644 | 176 | 3.15 / 176.11 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.19 | 352 | 882 | 4.03 / 176.99 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 28 | 15.14 | 493 | 209 | 0.21 / 169.14 | 2 | 2 |
2 | 12 | 1157.72 | 1 | 15.29 | 2076 | 32 | 0.24 / 169.17 | 2 | 2 |
3 | 7 | 2004.56 | 25 | 14.91 | 3159 | 1178 | 1.42 / 170.35 | 2 | 2 |
4 | 13 | 1611.76 | 18 | 14.87 | 2663 | 713 | 2.13 / 171.06 | 2 | 2 |
5 | 13 | 1059.32 | 18 | 14.98 | 1902 | 513 | 2.64 / 171.57 | 2 | 2 |
6 | 13 | 616.88 | 18 | 15.08 | 1283 | 348 | 2.99 / 171.92 | 2 | 3 |
7 | 13 | 156.76 | 18 | 15.21 | 610 | 167 | 3.16 / 172.09 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.20 | 348 | 873 | 4.03 / 172.96 | 2 | 4 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 28 | 15.15 | 503 | 213 | 0.21 / 165.10 | 2 | 2 |
2 | 12 | 1163.52 | 1 | 15.29 | 2066 | 32 | 0.24 / 165.13 | 2 | 2 |
3 | 7 | 2004.84 | 26 | 14.89 | 3148 | 1219 | 1.46 / 166.35 | 2 | 3 |
4 | 13 | 1741.68 | 18 | 14.83 | 2835 | 757 | 2.22 / 167.10 | 2 | 2 |
5 | 13 | 1026.80 | 18 | 14.98 | 1854 | 500 | 2.72 / 167.60 | 2 | 3 |
6 | 13 | 457.92 | 18 | 15.14 | 1057 | 288 | 3.01 / 167.89 | 2 | 3 |
7 | 13 | 162.56 | 18 | 15.20 | 622 | 170 | 3.18 / 168.06 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.21 | 345 | 866 | 4.04 / 168.93 | 2 | 3 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 27 | 15.16 | 497 | 203 | 0.20 / 161.01 | 2 | 2 |
2 | 12 | 1327.48 | 1 | 15.24 | 2315 | 35 | 0.24 / 161.05 | 2 | 2 |
3 | 7 | 2005.36 | 25 | 14.92 | 3170 | 1182 | 1.42 / 162.23 | 2 | 2 |
4 | 13 | 1737.92 | 18 | 14.83 | 2831 | 756 | 2.18 / 162.98 | 2 | 2 |
5 | 13 | 1152.04 | 18 | 14.95 | 2031 | 547 | 2.72 / 163.53 | 2 | 3 |
6 | 13 | 562.96 | 18 | 15.10 | 1210 | 329 | 3.05 / 163.86 | 2 | 3 |
7 | 13 | 145.44 | 18 | 15.21 | 595 | 163 | 3.22 / 164.02 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.20 | 343 | 860 | 4.08 / 164.88 | 2 | 6 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 27 | 15.17 | 495 | 203 | 0.20 / 156.82 | 2 | 2 |
2 | 12 | 1167.08 | 1 | 15.31 | 2074 | 32 | 0.23 / 156.86 | 2 | 2 |
3 | 7 | 2003.20 | 25 | 14.96 | 3164 | 1183 | 1.42 / 158.04 | 2 | 2 |
4 | 13 | 1732.68 | 18 | 14.86 | 2822 | 755 | 2.17 / 158.79 | 2 | 2 |
5 | 13 | 1155.24 | 18 | 14.96 | 2032 | 547 | 2.72 / 159.34 | 2 | 3 |
6 | 13 | 564.16 | 18 | 15.12 | 1213 | 330 | 3.05 / 159.67 | 2 | 3 |
7 | 13 | 143.72 | 18 | 15.23 | 593 | 163 | 3.21 / 159.83 | 2 | 3 |
8 | 13 | 32.08 | 18 | 15.24 | 413 | 113 | 3.33 / 159.95 | 2 | 2 |
9 | 8 | 0.04 | 165 | 15.20 | 343 | 860 | 4.19 / 160.81 | 2 | 10 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 27 | 15.14 | 505 | 206 | 0.21 / 152.69 | 2 | 2 |
2 | 12 | 1171.20 | 1 | 15.33 | 2086 | 32 | 0.24 / 152.72 | 2 | 2 |
3 | 7 | 2003.76 | 25 | 14.92 | 3152 | 1176 | 1.41 / 153.90 | 2 | 2 |
4 | 13 | 1730.72 | 18 | 14.86 | 2823 | 755 | 2.17 / 154.65 | 2 | 2 |
5 | 13 | 1119.36 | 18 | 14.97 | 1992 | 537 | 2.71 / 155.19 | 2 | 2 |
6 | 13 | 524.72 | 18 | 15.13 | 1160 | 316 | 3.02 / 155.51 | 2 | 4 |
7 | 13 | 117.08 | 18 | 15.24 | 542 | 149 | 3.17 / 155.65 | 2 | 3 |
8 | 13 | 25.80 | 18 | 15.25 | 397 | 109 | 3.28 / 155.76 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.20 | 342 | 858 | 4.14 / 156.62 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 27 | 15.15 | 483 | 198 | 0.20 / 148.53 | 2 | 2 |
2 | 12 | 1324.76 | 1 | 15.26 | 2312 | 35 | 0.23 / 148.57 | 2 | 2 |
3 | 7 | 2003.16 | 25 | 14.91 | 3159 | 1178 | 1.41 / 149.75 | 2 | 2 |
4 | 13 | 1728.16 | 18 | 14.85 | 2818 | 753 | 2.16 / 150.50 | 2 | 2 |
5 | 13 | 1134.72 | 18 | 14.95 | 2006 | 540 | 2.70 / 151.04 | 2 | 2 |
6 | 13 | 540.56 | 18 | 15.11 | 1172 | 319 | 3.02 / 151.36 | 2 | 3 |
7 | 13 | 129.32 | 18 | 15.22 | 567 | 155 | 3.18 / 151.51 | 2 | 2 |
8 | 13 | 28.04 | 18 | 15.24 | 402 | 110 | 3.29 / 151.62 | 2 | 3 |
9 | 8 | -0.04 | 165 | 15.20 | 343 | 860 | 4.15 / 152.48 | 2 | 6 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 27 | 15.17 | 485 | 199 | 0.20 / 144.45 | 2 | 2 |
2 | 12 | 1161.44 | 1 | 15.31 | 2072 | 32 | 0.23 / 144.48 | 2 | 2 |
3 | 7 | 2007.32 | 25 | 14.94 | 3161 | 1181 | 1.41 / 145.66 | 2 | 2 |
4 | 13 | 1609.04 | 18 | 14.88 | 2662 | 713 | 2.12 / 146.37 | 2 | 2 |
5 | 13 | 1179.84 | 18 | 14.96 | 2069 | 557 | 2.68 / 146.93 | 2 | 2 |
6 | 13 | 462.80 | 18 | 15.14 | 1064 | 290 | 2.97 / 147.22 | 2 | 3 |
7 | 13 | 117.16 | 18 | 15.23 | 545 | 149 | 3.12 / 147.37 | 2 | 3 |
8 | 13 | 27.08 | 18 | 15.24 | 397 | 109 | 3.23 / 147.48 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.20 | 342 | 858 | 4.09 / 148.34 | 2 | 6 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 27 | 15.15 | 482 | 197 | 0.20 / 140.27 | 2 | 2 |
2 | 12 | 1325.60 | 1 | 15.27 | 2320 | 35 | 0.23 / 140.31 | 2 | 2 |
3 | 7 | 2003.36 | 25 | 14.95 | 3163 | 1182 | 1.41 / 141.49 | 2 | 2 |
4 | 13 | 1738.08 | 18 | 14.85 | 2829 | 756 | 2.17 / 142.24 | 2 | 2 |
5 | 13 | 1154.32 | 18 | 14.96 | 2033 | 547 | 2.72 / 142.79 | 2 | 2 |
6 | 13 | 559.72 | 18 | 15.12 | 1200 | 327 | 3.04 / 143.12 | 2 | 3 |
7 | 13 | 142.16 | 18 | 15.23 | 581 | 159 | 3.20 / 143.28 | 2 | 2 |
8 | 13 | 31.32 | 18 | 15.24 | 406 | 111 | 3.32 / 143.39 | 2 | 2 |
9 | 8 | -0.04 | 165 | 15.20 | 343 | 860 | 4.18 / 144.25 | 2 | 7 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 27 | 15.15 | 488 | 200 | 0.20 / 136.27 | 2 | 2 |
2 | 12 | 1154.32 | 1 | 15.30 | 2045 | 31 | 0.23 / 136.30 | 2 | 2 |
3 | 7 | 2004.64 | 25 | 14.90 | 3149 | 1173 | 1.40 / 137.48 | 2 | 2 |
4 | 13 | 1605.08 | 18 | 14.87 | 2647 | 708 | 2.11 / 138.18 | 2 | 2 |
5 | 13 | 1075.28 | 18 | 14.97 | 1914 | 516 | 2.63 / 138.70 | 2 | 2 |
6 | 13 | 614.56 | 18 | 15.10 | 1276 | 347 | 2.97 / 139.05 | 2 | 3 |
7 | 13 | 148.40 | 18 | 15.23 | 593 | 163 | 3.14 / 139.21 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.21 | 344 | 863 | 4.00 / 140.07 | 2 | 6 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 27 | 15.16 | 492 | 201 | 0.20 / 132.22 | 2 | 2 |
2 | 12 | 1323.76 | 1 | 15.25 | 2310 | 35 | 0.24 / 132.25 | 2 | 2 |
3 | 7 | 2005.68 | 26 | 14.91 | 3157 | 1224 | 1.46 / 133.48 | 2 | 2 |
4 | 13 | 1622.24 | 18 | 14.87 | 2678 | 717 | 2.18 / 134.20 | 2 | 2 |
5 | 13 | 1187.04 | 18 | 14.95 | 2073 | 558 | 2.74 / 134.75 | 2 | 3 |
6 | 13 | 457.52 | 18 | 15.15 | 1055 | 288 | 3.02 / 135.04 | 2 | 3 |
7 | 13 | 161.76 | 18 | 15.22 | 613 | 168 | 3.19 / 135.21 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.21 | 344 | 863 | 4.05 / 136.07 | 2 | 6 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 27 | 15.18 | 493 | 202 | 0.20 / 128.15 | 2 | 2 |
2 | 12 | 1309.72 | 1 | 15.27 | 2284 | 35 | 0.24 / 128.18 | 2 | 2 |
3 | 7 | 2002.40 | 25 | 14.94 | 3152 | 1177 | 1.41 / 129.36 | 2 | 2 |
4 | 13 | 1741.00 | 18 | 14.87 | 2849 | 763 | 2.18 / 130.12 | 2 | 2 |
5 | 13 | 1161.68 | 18 | 14.97 | 2047 | 552 | 2.73 / 130.68 | 2 | 2 |
6 | 13 | 560.88 | 18 | 15.12 | 1204 | 328 | 3.06 / 131.00 | 2 | 3 |
7 | 13 | 134.08 | 18 | 15.24 | 569 | 156 | 3.21 / 131.16 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.22 | 342 | 859 | 4.07 / 132.02 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 27 | 15.19 | 503 | 206 | 0.21 / 124.21 | 2 | 2 |
2 | 12 | 1164.96 | 1 | 15.31 | 2087 | 32 | 0.24 / 124.24 | 2 | 2 |
3 | 7 | 2008.52 | 25 | 14.92 | 3153 | 1176 | 1.41 / 125.42 | 2 | 2 |
4 | 13 | 1617.04 | 18 | 14.88 | 2681 | 718 | 2.13 / 126.13 | 2 | 2 |
5 | 13 | 1054.24 | 18 | 15.00 | 1892 | 511 | 2.64 / 126.64 | 2 | 3 |
6 | 13 | 469.28 | 18 | 15.16 | 1072 | 293 | 2.94 / 126.94 | 2 | 3 |
7 | 13 | 113.76 | 18 | 15.25 | 542 | 149 | 3.08 / 127.09 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.22 | 343 | 861 | 3.95 / 127.95 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 27 | 15.18 | 494 | 202 | 0.20 / 120.17 | 2 | 2 |
2 | 12 | 1152.56 | 1 | 15.31 | 2054 | 31 | 0.23 / 120.20 | 2 | 2 |
3 | 7 | 2003.80 | 25 | 14.92 | 3180 | 1186 | 1.42 / 121.38 | 2 | 2 |
4 | 13 | 1602.76 | 18 | 14.91 | 2649 | 711 | 2.13 / 122.09 | 2 | 2 |
5 | 13 | 1170.24 | 18 | 14.98 | 2050 | 553 | 2.68 / 122.65 | 2 | 3 |
6 | 13 | 559.20 | 18 | 15.13 | 1200 | 327 | 3.01 / 122.97 | 2 | 3 |
7 | 13 | 135.80 | 18 | 15.25 | 575 | 158 | 3.17 / 123.13 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.23 | 346 | 869 | 4.04 / 124.00 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 27 | 15.17 | 492 | 202 | 0.20 / 116.18 | 2 | 2 |
2 | 12 | 1310.16 | 1 | 15.28 | 2283 | 35 | 0.24 / 116.22 | 2 | 2 |
3 | 7 | 2003.48 | 25 | 14.93 | 3166 | 1182 | 1.42 / 117.40 | 2 | 2 |
4 | 13 | 1734.72 | 18 | 14.88 | 2835 | 759 | 2.18 / 118.16 | 2 | 2 |
5 | 13 | 1020.80 | 18 | 15.01 | 1847 | 499 | 2.68 / 118.66 | 2 | 3 |
6 | 13 | 485.52 | 18 | 15.17 | 1099 | 300 | 2.98 / 118.96 | 2 | 3 |
7 | 13 | 104.44 | 18 | 15.25 | 522 | 143 | 3.12 / 119.10 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.23 | 344 | 864 | 3.98 / 119.96 | 2 | 6 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 27 | 15.18 | 489 | 200 | 0.20 / 112.12 | 2 | 2 |
2 | 12 | 1164.52 | 1 | 15.30 | 2084 | 32 | 0.23 / 112.15 | 2 | 2 |
3 | 7 | 2002.12 | 25 | 14.92 | 3161 | 1179 | 1.41 / 113.33 | 2 | 2 |
4 | 13 | 1734.40 | 18 | 14.86 | 2830 | 757 | 2.17 / 114.09 | 2 | 2 |
5 | 13 | 1138.84 | 18 | 14.98 | 2009 | 542 | 2.71 / 114.63 | 2 | 3 |
6 | 13 | 545.52 | 18 | 15.13 | 1188 | 324 | 3.03 / 114.95 | 2 | 3 |
7 | 13 | 135.04 | 18 | 15.25 | 572 | 157 | 3.19 / 115.11 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.23 | 346 | 869 | 4.06 / 115.98 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 27 | 15.20 | 492 | 202 | 0.20 / 108.15 | 2 | 2 |
2 | 12 | 1154.88 | 1 | 15.33 | 2060 | 32 | 0.23 / 108.18 | 2 | 2 |
3 | 7 | 2005.44 | 25 | 14.93 | 3158 | 1179 | 1.41 / 109.36 | 2 | 2 |
4 | 13 | 1613.96 | 18 | 14.90 | 2658 | 713 | 2.13 / 110.08 | 2 | 2 |
5 | 13 | 1043.72 | 18 | 15.01 | 1872 | 506 | 2.63 / 110.58 | 2 | 3 |
6 | 13 | 473.64 | 18 | 15.16 | 1079 | 294 | 2.93 / 110.88 | 2 | 3 |
7 | 13 | 176.88 | 18 | 15.24 | 640 | 176 | 3.10 / 111.05 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.24 | 345 | 868 | 3.97 / 111.92 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.16 | 27 | 15.19 | 528 | 217 | 0.22 / 104.20 | 2 | 2 |
2 | 12 | 1169.88 | 1 | 15.32 | 2073 | 32 | 0.25 / 104.23 | 2 | 2 |
3 | 7 | 2003.20 | 25 | 14.93 | 3167 | 1182 | 1.43 / 105.41 | 2 | 2 |
4 | 13 | 1610.84 | 18 | 14.92 | 2664 | 715 | 2.15 / 106.13 | 2 | 2 |
5 | 13 | 1055.20 | 18 | 15.02 | 1893 | 512 | 2.66 / 106.64 | 2 | 3 |
6 | 13 | 486.92 | 18 | 15.17 | 1096 | 299 | 2.96 / 106.94 | 2 | 3 |
7 | 13 | 112.08 | 18 | 15.25 | 532 | 146 | 3.10 / 107.09 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.23 | 344 | 864 | 3.97 / 107.95 | 2 | 6 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 27 | 15.19 | 495 | 203 | 0.20 / 100.14 | 2 | 2 |
2 | 3 | 1027.92 | 1 | 15.20 | 1886 | 29 | 0.23 / 100.17 | 2 | 2 |
3 | 12 | 1156.36 | 1 | 15.33 | 2059 | 32 | 0.26 / 100.20 | 2 | 2 |
4 | 7 | 2004.08 | 25 | 14.94 | 3153 | 1178 | 1.44 / 101.37 | 2 | 2 |
5 | 13 | 1606.72 | 18 | 14.90 | 2647 | 710 | 2.15 / 102.08 | 2 | 2 |
6 | 13 | 1168.88 | 18 | 14.98 | 2054 | 554 | 2.70 / 102.64 | 2 | 3 |
7 | 13 | 559.04 | 18 | 15.14 | 1196 | 326 | 3.03 / 102.96 | 2 | 3 |
8 | 13 | 134.56 | 18 | 15.24 | 569 | 156 | 3.19 / 103.12 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.24 | 343 | 863 | 4.05 / 103.98 | 2 | 9 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 26 | 15.19 | 504 | 199 | 0.20 / 96.12 | 2 | 2 |
2 | 12 | 1165.84 | 1 | 15.34 | 2065 | 32 | 0.23 / 96.15 | 2 | 2 |
3 | 7 | 2005.96 | 25 | 14.96 | 3156 | 1180 | 1.41 / 97.33 | 2 | 2 |
4 | 13 | 1610.36 | 18 | 14.91 | 2665 | 715 | 2.13 / 98.05 | 2 | 2 |
5 | 13 | 1052.72 | 18 | 15.02 | 1890 | 511 | 2.64 / 98.56 | 2 | 3 |
6 | 13 | 610.32 | 18 | 15.14 | 1278 | 348 | 2.99 / 98.91 | 2 | 3 |
7 | 13 | 149.80 | 18 | 15.26 | 595 | 163 | 3.15 / 99.07 | 2 | 2 |
8 | 8 | -0.08 | 165 | 15.24 | 344 | 865 | 4.01 / 99.93 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 27 | 15.20 | 491 | 202 | 0.20 / 92.05 | 2 | 2 |
2 | 3 | 960.48 | -1 | 15.56 | 0 | 0 | 0.00 / 92.05 | 2 | 2 |
3 | 12 | 1168.80 | 1 | 15.32 | 2073 | 32 | 0.23 / 92.08 | 2 | 2 |
4 | 7 | 2002.80 | 25 | 14.93 | 3165 | 1181 | 1.41 / 93.26 | 2 | 2 |
5 | 13 | 1749.12 | 18 | 14.88 | 2845 | 762 | 2.18 / 94.02 | 2 | 2 |
6 | 13 | 1161.08 | 18 | 14.99 | 2034 | 549 | 2.73 / 94.57 | 2 | 2 |
7 | 13 | 546.08 | 18 | 15.15 | 1182 | 322 | 3.05 / 94.89 | 2 | 3 |
8 | 13 | 132.40 | 18 | 15.26 | 567 | 156 | 3.20 / 95.05 | 2 | 3 |
9 | 8 | -0.08 | 165 | 15.24 | 346 | 870 | 4.07 / 95.92 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 28 | 15.20 | 516 | 220 | 0.22 / 88.08 | 2 | 2 |
2 | 12 | 1161.24 | 1 | 15.33 | 2070 | 32 | 0.25 / 88.11 | 2 | 2 |
3 | 7 | 2002.28 | 25 | 14.98 | 3177 | 1190 | 1.44 / 89.30 | 2 | 2 |
4 | 13 | 1614.80 | 18 | 14.92 | 2656 | 713 | 2.15 / 90.01 | 2 | 2 |
5 | 13 | 1054.00 | 18 | 15.02 | 1890 | 511 | 2.67 / 90.52 | 2 | 3 |
6 | 13 | 503.80 | 18 | 15.17 | 1121 | 306 | 2.97 / 90.83 | 2 | 3 |
7 | 13 | 117.68 | 18 | 15.27 | 546 | 150 | 3.12 / 90.98 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.25 | 345 | 868 | 3.99 / 91.85 | 2 | 7 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 27 | 15.22 | 513 | 211 | 0.21 / 83.78 | 2 | 2 |
2 | 3 | 1016.84 | 1 | 15.27 | 1857 | 28 | 0.24 / 83.81 | 2 | 2 |
3 | 12 | 1309.76 | 1 | 15.31 | 2297 | 35 | 0.27 / 83.85 | 2 | 2 |
4 | 7 | 2003.60 | 25 | 14.96 | 3187 | 1192 | 1.47 / 85.04 | 2 | 2 |
5 | 13 | 1733.48 | 18 | 14.90 | 2841 | 762 | 2.23 / 85.80 | 2 | 2 |
6 | 13 | 1148.24 | 18 | 15.00 | 2025 | 547 | 2.77 / 86.35 | 2 | 2 |
7 | 13 | 563.20 | 18 | 15.16 | 1205 | 329 | 3.10 / 86.68 | 2 | 3 |
8 | 13 | 141.84 | 18 | 15.26 | 579 | 159 | 3.26 / 86.84 | 2 | 3 |
9 | 8 | 0.24 | 165 | 15.25 | 344 | 866 | 4.13 / 87.70 | 2 | 8 |
10 | 14 | 0.24 | 30 | 15.22 | 340 | 155 | 4.28 / 87.86 | 2 | 12 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 28 | 15.21 | 494 | 210 | 0.21 / 79.78 | 2 | 2 |
2 | 12 | 1307.56 | 1 | 15.29 | 2283 | 35 | 0.25 / 79.81 | 2 | 2 |
3 | 7 | 2006.40 | 25 | 14.95 | 3153 | 1178 | 1.42 / 80.99 | 2 | 2 |
4 | 13 | 1744.92 | 18 | 14.91 | 2837 | 761 | 2.19 / 81.75 | 2 | 2 |
5 | 13 | 1018.52 | 18 | 15.05 | 1842 | 499 | 2.68 / 82.25 | 2 | 3 |
6 | 13 | 453.92 | 18 | 15.20 | 1054 | 288 | 2.97 / 82.54 | 2 | 3 |
7 | 13 | 159.36 | 18 | 15.27 | 603 | 166 | 3.14 / 82.70 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.26 | 345 | 869 | 4.01 / 83.57 | 2 | 8 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.68 | 27 | 15.22 | 514 | 211 | 0.21 / 75.71 | 2 | 2 |
2 | 12 | 1320.36 | 1 | 15.31 | 2298 | 35 | 0.25 / 75.74 | 2 | 2 |
3 | 7 | 2005.12 | 25 | 14.98 | 3152 | 1180 | 1.43 / 76.92 | 2 | 2 |
4 | 13 | 1750.52 | 18 | 14.90 | 2842 | 762 | 2.19 / 77.69 | 2 | 2 |
5 | 13 | 1146.80 | 18 | 15.01 | 2022 | 546 | 2.74 / 78.23 | 2 | 2 |
6 | 13 | 553.12 | 18 | 15.16 | 1193 | 326 | 3.06 / 78.56 | 2 | 3 |
7 | 13 | 143.76 | 18 | 15.27 | 576 | 158 | 3.22 / 78.72 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.27 | 337 | 849 | 4.07 / 79.57 | 2 | 6 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 122.00 | 28 | 15.22 | 525 | 224 | 0.22 / 71.73 | 2 | 2 |
2 | 12 | 1298.84 | 1 | 15.31 | 2293 | 35 | 0.26 / 71.77 | 2 | 2 |
3 | 7 | 2003.04 | 25 | 14.99 | 3147 | 1179 | 1.44 / 72.95 | 2 | 2 |
4 | 13 | 1743.44 | 18 | 14.92 | 2822 | 758 | 2.20 / 73.71 | 2 | 2 |
5 | 13 | 1025.12 | 18 | 15.06 | 1844 | 500 | 2.70 / 74.21 | 2 | 3 |
6 | 13 | 474.88 | 18 | 15.19 | 1073 | 293 | 2.99 / 74.50 | 2 | 3 |
7 | 13 | 110.48 | 18 | 15.28 | 523 | 144 | 3.13 / 74.64 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.27 | 339 | 854 | 3.99 / 75.50 | 2 | 6 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.00 | 27 | 15.21 | 522 | 214 | 0.21 / 67.60 | 2 | 2 |
2 | 12 | 1317.08 | 1 | 15.33 | 2295 | 35 | 0.25 / 67.63 | 2 | 2 |
3 | 7 | 2004.16 | 26 | 14.98 | 3153 | 1228 | 1.48 / 68.86 | 2 | 2 |
4 | 13 | 1742.40 | 18 | 14.91 | 2835 | 761 | 2.24 / 69.62 | 2 | 2 |
5 | 13 | 1142.64 | 18 | 15.03 | 2009 | 544 | 2.78 / 70.16 | 2 | 2 |
6 | 13 | 553.44 | 18 | 15.18 | 1190 | 325 | 3.11 / 70.49 | 2 | 3 |
7 | 13 | 134.52 | 18 | 15.28 | 564 | 155 | 3.26 / 70.64 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.27 | 344 | 867 | 4.13 / 71.51 | 2 | 6 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 27 | 15.23 | 521 | 214 | 0.21 / 63.49 | 2 | 2 |
2 | 12 | 1166.04 | 1 | 15.36 | 2058 | 32 | 0.25 / 63.52 | 2 | 2 |
3 | 7 | 2005.36 | 25 | 15.00 | 3160 | 1185 | 1.43 / 64.71 | 2 | 2 |
4 | 13 | 1743.16 | 18 | 14.94 | 2835 | 762 | 2.19 / 65.47 | 2 | 2 |
5 | 13 | 1145.52 | 18 | 15.04 | 2024 | 548 | 2.74 / 66.02 | 2 | 2 |
6 | 13 | 560.68 | 18 | 15.19 | 1202 | 329 | 3.07 / 66.35 | 2 | 3 |
7 | 13 | 140.84 | 18 | 15.29 | 578 | 159 | 3.23 / 66.50 | 2 | 3 |
8 | 8 | -0.08 | 165 | 15.28 | 348 | 877 | 4.11 / 67.38 | 2 | 5 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 27 | 15.21 | 495 | 203 | 0.20 / 59.48 | 2 | 2 |
2 | 12 | 1149.88 | 1 | 15.36 | 2047 | 31 | 0.23 / 59.51 | 2 | 2 |
3 | 7 | 2006.92 | 26 | 14.97 | 3161 | 1230 | 1.47 / 60.74 | 2 | 2 |
4 | 13 | 1612.16 | 18 | 14.94 | 2654 | 714 | 2.18 / 61.45 | 2 | 2 |
5 | 13 | 1054.32 | 18 | 15.05 | 1888 | 511 | 2.69 / 61.97 | 2 | 3 |
6 | 13 | 482.24 | 18 | 15.20 | 1086 | 297 | 2.99 / 62.26 | 2 | 3 |
7 | 13 | 112.00 | 18 | 15.29 | 529 | 146 | 3.13 / 62.41 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.27 | 344 | 867 | 4.00 / 63.28 | 2 | 7 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 28 | 15.23 | 512 | 218 | 0.22 / 55.48 | 2 | 2 |
2 | 12 | 1145.32 | 1 | 15.36 | 2049 | 31 | 0.25 / 55.51 | 2 | 2 |
3 | 7 | 2002.60 | 26 | 14.96 | 3164 | 1231 | 1.48 / 56.74 | 2 | 2 |
4 | 13 | 1594.44 | 18 | 14.94 | 2639 | 710 | 2.19 / 57.45 | 2 | 2 |
5 | 13 | 1026.32 | 18 | 15.06 | 1850 | 501 | 2.69 / 57.95 | 2 | 3 |
6 | 13 | 452.96 | 18 | 15.20 | 1051 | 288 | 2.98 / 58.24 | 2 | 3 |
7 | 13 | 155.96 | 18 | 15.27 | 603 | 166 | 3.14 / 58.40 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.26 | 347 | 874 | 4.02 / 59.28 | 2 | 8 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 27 | 15.23 | 493 | 203 | 0.20 / 51.43 | 2 | 2 |
2 | 3 | 1025.84 | 1 | 15.27 | 1894 | 29 | 0.23 / 51.46 | 2 | 2 |
3 | 12 | 1309.20 | 1 | 15.32 | 2289 | 35 | 0.27 / 51.49 | 2 | 2 |
4 | 7 | 2007.40 | 25 | 14.97 | 3173 | 1187 | 1.45 / 52.68 | 2 | 2 |
5 | 13 | 1589.92 | 18 | 14.96 | 2634 | 709 | 2.16 / 53.39 | 2 | 3 |
6 | 13 | 1029.92 | 18 | 15.06 | 1858 | 504 | 2.67 / 53.89 | 2 | 3 |
7 | 13 | 573.60 | 18 | 15.18 | 1225 | 335 | 3.00 / 54.23 | 2 | 3 |
8 | 13 | 134.36 | 18 | 15.29 | 568 | 156 | 3.16 / 54.38 | 2 | 3 |
9 | 8 | 0.16 | 165 | 15.28 | 347 | 875 | 4.03 / 55.26 | 2 | 7 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 27 | 15.23 | 492 | 202 | 0.20 / 47.29 | 2 | 2 |
2 | 12 | 1319.80 | 1 | 15.33 | 2301 | 35 | 0.24 / 47.33 | 2 | 2 |
3 | 7 | 2004.08 | 26 | 14.96 | 3174 | 1235 | 1.47 / 48.56 | 2 | 2 |
4 | 13 | 1745.16 | 18 | 14.92 | 2841 | 763 | 2.24 / 49.33 | 2 | 2 |
5 | 13 | 1145.60 | 18 | 15.05 | 2022 | 548 | 2.78 / 49.88 | 2 | 2 |
6 | 13 | 535.32 | 18 | 15.19 | 1172 | 320 | 3.10 / 50.20 | 2 | 3 |
7 | 13 | 124.40 | 18 | 15.29 | 556 | 153 | 3.26 / 50.35 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.28 | 347 | 875 | 4.13 / 51.22 | 2 | 5 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 27 | 15.22 | 486 | 200 | 0.20 / 43.24 | 2 | 2 |
2 | 12 | 1167.84 | 1 | 15.35 | 2066 | 32 | 0.23 / 43.27 | 2 | 2 |
3 | 7 | 2005.60 | 25 | 14.98 | 3166 | 1186 | 1.42 / 44.46 | 2 | 2 |
4 | 13 | 1737.20 | 18 | 14.93 | 2832 | 761 | 2.18 / 45.22 | 2 | 2 |
5 | 13 | 1128.24 | 18 | 15.04 | 1996 | 540 | 2.72 / 45.76 | 2 | 3 |
6 | 13 | 529.80 | 18 | 15.20 | 1158 | 317 | 3.04 / 46.08 | 2 | 3 |
7 | 13 | 122.24 | 18 | 15.30 | 548 | 151 | 3.19 / 46.23 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.28 | 343 | 865 | 4.05 / 47.09 | 2 | 5 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.92 | 27 | 15.24 | 514 | 212 | 0.21 / 39.20 | 2 | 2 |
2 | 12 | 1309.76 | 1 | 15.33 | 2287 | 35 | 0.25 / 39.24 | 2 | 2 |
3 | 7 | 2008.88 | 25 | 14.99 | 3160 | 1184 | 1.43 / 40.42 | 2 | 2 |
4 | 13 | 1613.16 | 18 | 14.96 | 2663 | 717 | 2.15 / 41.14 | 2 | 2 |
5 | 13 | 1179.12 | 18 | 15.04 | 2062 | 558 | 2.71 / 41.70 | 2 | 2 |
6 | 13 | 554.32 | 18 | 15.18 | 1189 | 325 | 3.03 / 42.02 | 2 | 3 |
7 | 13 | 131.00 | 18 | 15.29 | 561 | 154 | 3.19 / 42.18 | 2 | 3 |
8 | 8 | -0.12 | 165 | 15.28 | 343 | 865 | 4.05 / 43.04 | 2 | 4 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 28 | 15.24 | 491 | 210 | 0.21 / 35.09 | 2 | 2 |
2 | 3 | 967.56 | -1 | 15.63 | 0 | 0 | 0.00 / 35.09 | 2 | 2 |
3 | 12 | 1307.24 | 1 | 15.34 | 2280 | 35 | 0.24 / 35.12 | 2 | 2 |
4 | 7 | 2004.36 | 25 | 15.02 | 3165 | 1188 | 1.43 / 36.31 | 2 | 2 |
5 | 13 | 1745.40 | 18 | 14.95 | 2836 | 763 | 2.20 / 37.07 | 2 | 2 |
6 | 13 | 1277.08 | 18 | 15.01 | 2199 | 594 | 2.79 / 37.67 | 2 | 2 |
7 | 13 | 518.64 | 18 | 15.20 | 1142 | 312 | 3.10 / 37.98 | 2 | 3 |
8 | 13 | 130.20 | 18 | 15.30 | 556 | 153 | 3.26 / 38.13 | 2 | 3 |
9 | 8 | -0.04 | 165 | 15.29 | 340 | 858 | 4.11 / 38.99 | 2 | 6 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 27 | 15.24 | 497 | 205 | 0.20 / 31.00 | 2 | 2 |
2 | 3 | 1036.76 | 1 | 15.25 | 1916 | 29 | 0.23 / 31.03 | 2 | 2 |
3 | 12 | 1313.84 | 1 | 15.32 | 2284 | 35 | 0.27 / 31.07 | 2 | 2 |
4 | 7 | 2004.12 | 25 | 14.99 | 3163 | 1185 | 1.45 / 32.25 | 2 | 2 |
5 | 13 | 1741.92 | 18 | 14.95 | 2843 | 765 | 2.22 / 33.02 | 2 | 2 |
6 | 13 | 1146.12 | 18 | 15.05 | 2017 | 546 | 2.77 / 33.56 | 2 | 3 |
7 | 13 | 514.96 | 18 | 15.21 | 1133 | 310 | 3.08 / 33.87 | 2 | 3 |
8 | 13 | 120.48 | 18 | 15.30 | 538 | 148 | 3.22 / 34.02 | 2 | 2 |
9 | 8 | 0.04 | 165 | 15.28 | 340 | 857 | 4.08 / 34.88 | 2 | 5 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 27 | 15.23 | 500 | 206 | 0.21 / 26.97 | 2 | 2 |
2 | 12 | 1313.36 | 1 | 15.30 | 2302 | 35 | 0.24 / 27.00 | 2 | 2 |
3 | 7 | 2003.36 | 25 | 15.01 | 3142 | 1179 | 1.42 / 28.18 | 2 | 2 |
4 | 13 | 1739.00 | 18 | 14.94 | 2820 | 758 | 2.18 / 28.94 | 2 | 2 |
5 | 13 | 1141.60 | 18 | 15.04 | 2000 | 541 | 2.72 / 29.48 | 2 | 3 |
6 | 13 | 546.36 | 18 | 15.18 | 1176 | 321 | 3.04 / 29.80 | 2 | 3 |
7 | 13 | 127.68 | 18 | 15.29 | 547 | 151 | 3.19 / 29.95 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.28 | 334 | 842 | 4.03 / 30.80 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 26 | 15.26 | 507 | 201 | 0.20 / 22.04 | 2 | 2 |
2 | 3 | 1043.92 | 1 | 15.28 | 1920 | 29 | 0.23 / 22.06 | 2 | 2 |
3 | 7 | 2004.12 | 75 | 14.76 | 3145 | 3482 | 3.71 / 25.55 | 2 | 3 |
4 | 13 | 317.00 | 18 | 15.27 | 834 | 229 | 3.94 / 25.78 | 2 | 3 |
5 | 13 | 79.36 | 18 | 15.32 | 474 | 131 | 4.07 / 25.91 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.28 | 340 | 857 | 4.93 / 26.76 | 2 | 6 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 28 | 15.25 | 503 | 215 | 0.21 / 17.22 | 2 | 2 |
2 | 3 | 928.32 | -1 | 15.64 | 0 | 0 | 0.00 / 17.22 | 2 | 2 |
3 | 3 | 971.16 | -1 | 15.65 | 0 | 0 | 0.00 / 17.22 | 2 | 2 |
4 | 7 | 2002.56 | 74 | 14.77 | 3134 | 3425 | 3.64 / 20.64 | 2 | 2 |
5 | 13 | 326.80 | 18 | 15.28 | 845 | 232 | 3.87 / 20.87 | 2 | 3 |
6 | 13 | 46.08 | 18 | 15.34 | 418 | 115 | 3.99 / 20.99 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.30 | 335 | 846 | 4.83 / 21.83 | 2 | 5 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 28 | 15.24 | 503 | 215 | 0.21 / 13.20 | 2 | 2 |
2 | 3 | 959.24 | -1 | 15.63 | 0 | 0 | 0.00 / 13.20 | 2 | 2 |
3 | 7 | 1522.80 | 74 | 14.94 | 2498 | 2762 | 2.98 / 15.97 | 2 | 3 |
4 | 13 | 222.56 | 18 | 15.31 | 695 | 192 | 3.17 / 16.16 | 2 | 2 |
5 | 8 | 0.00 | 165 | 15.30 | 334 | 843 | 4.01 / 17.00 | 2 | 5 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 25 | 15.26 | 511 | 195 | 0.19 / 9.12 | 2 | 2 |
2 | 10 | 1012.32 | 2 | 15.21 | 1858 | 57 | 0.25 / 9.18 | 2 | 2 |
3 | 3 | 1032.72 | 1 | 15.27 | 1885 | 29 | 0.28 / 9.21 | 2 | 2 |
4 | 7 | 1522.56 | 74 | 14.93 | 2490 | 2751 | 3.03 / 11.96 | 2 | 3 |
5 | 13 | 225.92 | 18 | 15.30 | 703 | 194 | 3.22 / 12.15 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.30 | 331 | 836 | 4.06 / 12.99 | 2 | 4 |
Average= | 3.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 31 | 15.29 | 481 | 228 | 0.23 / 5.14 | 2 | 2 |
2 | 3 | 822.84 | -3 | 15.66 | 0 | 0 | 0.00 / 5.14 | 2 | 2 |
3 | 3 | 923.36 | -1 | 15.67 | 0 | 0 | 0.00 / 5.14 | 2 | 2 |
4 | 7 | 1526.88 | 74 | 14.94 | 2498 | 2762 | 2.99 / 7.90 | 2 | 2 |
5 | 13 | 212.92 | 18 | 15.30 | 679 | 187 | 3.18 / 8.09 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.30 | 334 | 843 | 4.02 / 8.93 | 2 | 4 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.92 | 26 | 15.43 | 481 | 193 | 0.19 / 1.99 | 2 | 2 |
2 | 10 | 1036.08 | 2 | 15.28 | 1899 | 58 | 0.25 / 2.05 | 2 | 2 |
3 | 3 | 1037.20 | 1 | 15.30 | 1905 | 29 | 0.28 / 2.07 | 2 | 2 |
4 | 7 | 1003.64 | 74 | 15.12 | 1777 | 1988 | 2.27 / 4.06 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.35 | 334 | 846 | 3.11 / 4.91 | 2 | 7 |
Average= | 2.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 25 | 15.60 | 463 | 181 | 0.18 / 0.18 | 2 | 2 |
2 | 7 | 122.72 | 74 | 15.56 | 476 | 548 | 0.73 / 0.73 | 2 | 2 |
3 | 8 | 0.28 | 240 | 15.53 | 286 | 1066 | 1.79 / 1.79 | 2 | 6 |
Average= | 1.79 (KJ/cycle) |