SIO Argo Site:
Pump Diagnostics Page   



Serial= 8883 WMO= 4903400

Return

←PreviousNext→

Cycle 152 GMT 9/11/2024 19:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 29 14.96 415 180 0.18 / 568.82 2 3
2 7 2007.20 31 14.80 2959 1358 1.54 / 570.18 2 3
3 13 1590.64 24 14.78 2431 862 2.40 / 571.04 2 3
4 13 830.16 24 14.87 1412 504 2.90 / 571.55 2 3
5 13 139.76 24 15.04 481 174 3.08 / 571.72 2 5
6 8 0.08 165 15.04 259 643 3.72 / 572.36 2 10
Average= 3.74
(KJ/cycle)

Cycle 151 GMT 31/10/2024 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 29 14.98 406 176 0.18 / 564.96 2 3
2 7 2011.72 31 14.80 2956 1356 1.53 / 566.31 2 3
3 13 1596.96 24 14.79 2433 864 2.40 / 567.18 2 3
4 13 838.76 24 14.88 1427 510 2.91 / 567.69 2 3
5 13 192.68 24 15.03 553 199 3.11 / 567.89 2 3
6 13 18.92 24 15.07 296 107 3.21 / 567.99 2 3
7 8 0.08 165 15.03 262 650 3.86 / 568.64 2 9
Average= 3.74
(KJ/cycle)

Cycle 150 GMT 21/10/2024 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 14.98 407 177 0.18 / 561.09 2 3
2 7 2011.60 31 14.80 2948 1353 1.53 / 562.44 2 3
3 13 1596.08 24 14.78 2429 862 2.39 / 563.30 2 3
4 13 834.52 24 14.88 1427 510 2.90 / 563.81 2 3
5 13 206.64 24 15.03 571 206 3.11 / 564.02 2 3
6 13 19.48 24 15.06 298 108 3.21 / 564.13 2 4
7 8 0.04 165 15.04 264 655 3.87 / 564.78 2 6
Average= 3.74
(KJ/cycle)

Cycle 149 GMT 11/10/2024 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 29 14.99 409 178 0.18 / 557.14 2 3
2 7 2008.76 31 14.80 2947 1352 1.53 / 558.50 2 3
3 13 1733.00 24 14.76 2606 923 2.45 / 559.42 2 3
4 13 937.80 24 14.86 1555 555 3.01 / 559.97 2 3
5 13 163.68 24 15.04 512 185 3.19 / 560.16 2 3
6 13 21.00 24 15.06 299 108 3.30 / 560.27 2 4
7 8 -0.04 165 15.02 260 644 3.94 / 560.91 2 8
Average= 3.74
(KJ/cycle)

Cycle 148 GMT 1/10/2024 15:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 29 14.98 407 177 0.18 / 553.30 2 3
2 7 2011.32 31 14.80 2955 1356 1.53 / 554.66 2 3
3 13 1605.08 24 14.78 2443 867 2.40 / 555.52 2 3
4 13 846.76 24 14.88 1442 515 2.91 / 556.04 2 3
5 13 137.80 24 15.05 475 172 3.09 / 556.21 2 3
6 13 31.44 24 15.06 314 113 3.20 / 556.32 2 2
7 8 0.08 165 15.03 260 645 3.84 / 556.97 2 15
Average= 3.74
(KJ/cycle)

Cycle 147 GMT 21/ 9/2024 20:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 29 14.99 402 175 0.17 / 549.46 2 3
2 7 2003.28 31 14.80 2945 1351 1.53 / 550.81 2 3
3 13 1605.72 24 14.79 2433 864 2.39 / 551.67 2 4
4 13 842.24 24 14.89 1433 512 2.90 / 552.18 2 3
5 13 137.28 24 15.04 483 174 3.08 / 552.36 2 3
6 13 30.48 24 15.06 314 113 3.19 / 552.47 2 3
7 8 0.08 165 15.05 262 651 3.84 / 553.12 2 11
Average= 3.74
(KJ/cycle)

Cycle 146 GMT 12/ 9/2024 1:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 14.97 407 177 0.18 / 545.58 2 3
2 7 2008.24 31 14.83 2943 1353 1.53 / 546.93 2 3
3 13 1605.64 24 14.78 2448 868 2.40 / 547.80 2 2
4 13 853.44 24 14.89 1444 516 2.91 / 548.31 2 3
5 13 219.04 24 15.03 590 213 3.13 / 548.53 2 3
6 13 22.84 24 15.07 302 109 3.24 / 548.64 2 5
7 8 0.00 165 15.05 260 646 3.88 / 549.28 3 13
Average= 3.74
(KJ/cycle)

Cycle 145 GMT 2/ 9/2024 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 29 14.99 408 177 0.18 / 541.69 2 3
2 7 2012.96 31 14.81 2955 1357 1.53 / 543.05 2 3
3 13 1593.16 24 14.79 2434 864 2.40 / 543.91 2 3
4 13 853.20 24 14.90 1443 516 2.91 / 544.43 2 3
5 13 218.72 24 15.03 588 212 3.13 / 544.64 2 4
6 13 20.36 24 15.08 300 109 3.23 / 544.75 2 2
7 8 -0.04 165 15.04 262 650 3.88 / 545.40 2 8
Average= 3.74
(KJ/cycle)

Cycle 144 GMT 23/ 8/2024 11:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 14.97 408 177 0.18 / 537.82 2 3
2 7 2009.32 32 14.81 2940 1393 1.57 / 539.21 2 3
3 13 1591.64 24 14.79 2429 862 2.43 / 540.08 2 4
4 13 839.48 24 14.89 1427 510 2.94 / 540.59 2 4
5 13 140.84 24 15.06 481 174 3.12 / 540.76 2 3
6 13 15.04 24 15.08 291 105 3.22 / 540.87 2 3
7 8 0.16 165 15.05 262 651 3.87 / 541.52 2 8
Average= 3.73
(KJ/cycle)

Cycle 143 GMT 13/ 8/2024 16:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 29 14.98 407 177 0.18 / 534.00 2 3
2 7 2009.04 31 14.82 2943 1352 1.53 / 535.35 2 3
3 13 1590.76 24 14.79 2423 860 2.39 / 536.21 2 3
4 13 837.64 24 14.89 1426 510 2.90 / 536.72 2 3
5 13 136.12 24 15.06 473 171 3.07 / 536.89 2 4
6 13 15.76 24 15.08 288 104 3.17 / 537.00 2 5
7 8 0.04 165 15.03 260 645 3.82 / 537.64 2 4
Average= 3.73
(KJ/cycle)

Cycle 142 GMT 3/ 8/2024 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 29 15.00 400 174 0.17 / 530.13 2 3
2 7 2009.60 31 14.82 2954 1357 1.53 / 531.49 2 3
3 13 1597.68 24 14.79 2440 866 2.40 / 532.36 2 3
4 13 827.20 24 14.90 1413 505 2.90 / 532.86 2 3
5 13 194.44 24 15.04 555 200 3.10 / 533.06 2 4
6 13 18.08 24 15.07 294 106 3.21 / 533.17 2 4
7 8 0.04 165 15.04 264 655 3.86 / 533.83 2 5
Average= 3.73
(KJ/cycle)

Cycle 141 GMT 25/ 7/2024 2:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 29 14.99 421 183 0.18 / 526.30 2 3
2 7 2006.12 31 14.81 2952 1355 1.54 / 527.66 2 2
3 13 1735.40 24 14.76 2614 926 2.46 / 528.59 2 3
4 13 929.80 24 14.88 1550 554 3.02 / 529.14 2 3
5 13 153.40 24 15.05 493 178 3.20 / 529.32 2 5
6 8 0.08 165 15.06 259 644 3.84 / 529.96 2 4
Average= 3.73
(KJ/cycle)

Cycle 140 GMT 15/ 7/2024 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 29 15.00 410 178 0.18 / 522.35 2 3
2 7 2011.88 31 14.82 2958 1359 1.54 / 523.71 2 3
3 13 1737.52 24 14.77 2617 928 2.46 / 524.64 2 3
4 13 820.36 24 14.91 1404 502 2.97 / 525.14 2 4
5 13 208.28 24 15.04 573 207 3.17 / 525.35 2 3
6 13 17.56 24 15.09 298 108 3.28 / 525.46 2 2
7 8 0.08 165 15.05 267 663 3.95 / 526.12 2 16
Average= 3.73
(KJ/cycle)

Cycle 139 GMT 5/ 7/2024 12:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.99 408 177 0.18 / 518.63 2 2
2 7 2013.92 31 14.82 2959 1359 1.54 / 519.98 2 2
3 13 1599.80 24 14.79 2432 863 2.40 / 520.85 2 4
4 13 834.24 24 14.90 1424 509 2.91 / 521.36 2 3
5 13 141.64 24 15.05 479 173 3.08 / 521.53 2 4
6 8 0.16 165 15.06 260 646 3.73 / 522.18 2 5
Average= 3.73
(KJ/cycle)

Cycle 138 GMT 25/ 6/2024 17:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 15.01 406 177 0.18 / 514.81 2 3
2 7 2014.96 32 14.82 2965 1406 1.58 / 516.21 2 3
3 13 1612.36 24 14.79 2450 870 2.45 / 517.08 2 3
4 13 846.76 24 14.90 1428 511 2.96 / 517.59 2 3
5 13 213.00 24 15.03 578 208 3.17 / 517.80 2 4
6 8 0.08 165 15.06 260 646 3.82 / 518.45 2 13
Average= 3.73
(KJ/cycle)

Cycle 137 GMT 15/ 6/2024 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 15.00 407 177 0.18 / 511.11 2 3
2 7 2010.48 31 14.82 2959 1359 1.54 / 512.47 2 3
3 13 1613.12 24 14.80 2448 870 2.41 / 513.34 2 3
4 13 737.12 24 14.93 1296 464 2.87 / 513.80 2 3
5 13 167.04 24 15.06 515 186 3.06 / 513.99 2 3
6 8 0.08 165 15.07 258 642 3.70 / 514.63 2 9
Average= 3.73
(KJ/cycle)

Cycle 136 GMT 6/ 6/2024 3:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 29 14.98 405 176 0.18 / 507.28 2 3
2 7 2003.36 31 14.83 2936 1350 1.53 / 508.63 2 3
3 13 1731.08 24 14.78 2593 920 2.45 / 509.55 2 3
4 13 924.88 24 14.89 1542 551 3.00 / 510.10 2 3
5 13 171.32 24 15.06 521 188 3.18 / 510.29 2 3
6 8 0.00 165 15.07 259 644 3.83 / 510.93 2 4
Average= 3.73
(KJ/cycle)

Cycle 135 GMT 27/ 5/2024 8:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 15.00 406 177 0.18 / 503.54 2 3
2 7 2007.56 31 14.81 2940 1350 1.53 / 504.89 2 3
3 13 1599.28 24 14.79 2421 859 2.39 / 505.75 2 3
4 13 834.20 24 14.90 1423 509 2.89 / 506.25 2 3
5 13 206.40 24 15.03 570 206 3.10 / 506.46 2 4
6 8 -0.04 165 15.05 259 643 3.74 / 507.10 2 5
Average= 3.73
(KJ/cycle)

Cycle 134 GMT 17/ 5/2024 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 29 15.00 420 183 0.18 / 499.77 2 2
2 7 2009.04 31 14.82 2952 1356 1.54 / 501.13 2 3
3 13 1608.36 24 14.81 2446 869 2.41 / 502.00 2 3
4 13 837.96 24 14.90 1426 510 2.92 / 502.51 2 3
5 13 210.24 24 15.05 571 206 3.12 / 502.71 2 3
6 8 0.00 165 15.06 260 646 3.77 / 503.36 2 10
Average= 3.73
(KJ/cycle)

Cycle 133 GMT 7/ 5/2024 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 29 15.00 412 179 0.18 / 495.92 2 3
2 7 2009.52 31 14.82 2957 1359 1.54 / 497.28 2 3
3 13 1735.88 24 14.78 2609 925 2.46 / 498.20 2 4
4 13 913.72 24 14.89 1531 547 3.01 / 498.75 2 3
5 13 171.04 24 15.06 524 189 3.20 / 498.94 2 3
6 8 0.12 165 15.06 261 649 3.85 / 499.59 2 10
Average= 3.73
(KJ/cycle)

Cycle 132 GMT 27/ 4/2024 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 14.99 415 180 0.18 / 492.01 2 3
2 7 2011.48 32 14.82 2953 1400 1.58 / 493.41 2 3
3 13 1742.20 24 14.78 2605 924 2.50 / 494.34 2 3
4 13 930.60 24 14.89 1553 555 3.06 / 494.89 2 3
5 13 184.24 24 15.05 535 193 3.25 / 495.09 2 3
6 8 0.00 165 15.07 263 654 3.91 / 495.74 2 7
Average= 3.73
(KJ/cycle)

Cycle 131 GMT 18/ 4/2024 4:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 29 14.99 409 178 0.18 / 488.24 2 3
2 7 2008.60 31 14.82 2954 1357 1.53 / 489.60 2 3
3 13 1593.56 24 14.80 2438 866 2.40 / 490.46 2 4
4 13 832.88 24 14.91 1426 510 2.91 / 490.97 2 3
5 13 200.92 24 15.04 562 203 3.11 / 491.18 2 3
6 8 0.00 165 15.06 264 656 3.77 / 491.83 2 8
Average= 3.73
(KJ/cycle)

Cycle 130 GMT 8/ 4/2024 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 15.00 420 183 0.18 / 484.50 2 3
2 7 2007.12 31 14.81 2934 1347 1.53 / 485.85 2 3
3 13 1587.84 24 14.79 2417 858 2.39 / 486.70 2 3
4 13 832.92 24 14.91 1423 509 2.90 / 487.21 2 3
5 13 198.92 24 15.05 562 203 3.10 / 487.42 2 3
6 8 0.16 165 15.06 261 649 3.75 / 488.06 2 9
Average= 3.73
(KJ/cycle)

Cycle 129 GMT 29/ 3/2024 14:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 29 15.00 404 176 0.18 / 480.73 2 2
2 7 2008.20 31 14.81 2947 1353 1.53 / 482.08 2 2
3 13 1593.56 24 14.80 2425 861 2.39 / 482.94 2 3
4 13 839.68 24 14.91 1427 511 2.90 / 483.45 2 3
5 13 208.88 24 15.05 581 210 3.11 / 483.66 2 4
6 8 0.04 165 15.07 262 651 3.76 / 484.32 2 4
Average= 3.73
(KJ/cycle)

Cycle 128 GMT 19/ 3/2024 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 29 15.00 409 178 0.18 / 476.95 2 3
2 7 2009.84 31 14.82 2962 1361 1.54 / 478.31 2 2
3 13 1602.68 24 14.80 2446 869 2.41 / 479.18 2 3
4 13 843.96 24 14.90 1433 512 2.92 / 479.69 2 3
5 13 205.76 24 15.05 574 207 3.13 / 479.90 2 3
6 8 -0.04 165 15.07 262 651 3.78 / 480.55 2 4
Average= 3.73
(KJ/cycle)

Cycle 127 GMT 10/ 3/2024 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 15.02 413 180 0.18 / 473.10 2 3
2 7 2004.92 31 14.83 2937 1350 1.53 / 474.45 2 3
3 13 1741.60 24 14.79 2619 930 2.46 / 475.38 2 3
4 13 850.52 24 14.90 1443 516 2.98 / 475.90 2 4
5 13 229.36 24 15.04 605 218 3.19 / 476.12 2 3
6 8 0.08 165 15.07 264 656 3.85 / 476.77 2 5
Average= 3.72
(KJ/cycle)

Cycle 126 GMT 29/ 2/2024 5:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 29 15.01 415 181 0.18 / 469.35 2 3
2 7 2010.68 31 14.83 2962 1362 1.54 / 470.71 2 3
3 13 1616.84 24 14.81 2463 875 2.42 / 471.58 2 3
4 13 847.76 24 14.91 1441 516 2.93 / 472.10 2 3
5 13 154.04 24 15.07 497 180 3.11 / 472.28 2 3
6 8 0.12 165 15.08 259 644 3.76 / 472.92 2 7
Average= 3.72
(KJ/cycle)

Cycle 125 GMT 19/ 2/2024 10:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 15.00 409 178 0.18 / 465.61 2 3
2 7 2004.64 32 14.83 2946 1398 1.58 / 467.01 2 3
3 13 1604.32 24 14.80 2437 866 2.44 / 467.87 2 3
4 13 735.08 24 14.93 1297 465 2.91 / 468.34 2 3
5 13 159.84 24 15.06 511 185 3.09 / 468.52 2 3
6 8 0.00 165 15.07 259 644 3.74 / 469.17 2 9
Average= 3.72
(KJ/cycle)

Cycle 124 GMT 9/ 2/2024 15:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 29 14.99 408 177 0.18 / 461.80 2 2
2 7 2002.48 32 14.83 2954 1402 1.58 / 463.21 2 3
3 13 1574.04 24 14.81 2400 853 2.43 / 464.06 2 4
4 13 825.60 24 14.92 1410 505 2.94 / 464.56 2 4
5 13 198.72 24 15.06 561 203 3.14 / 464.77 2 3
6 8 0.12 165 15.07 267 664 3.80 / 465.43 2 4
Average= 3.72
(KJ/cycle)

Cycle 123 GMT 30/ 1/2024 20:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 29 15.01 415 181 0.18 / 458.05 2 3
2 7 2008.60 31 14.82 2956 1358 1.54 / 459.40 2 3
3 13 1590.48 24 14.79 2421 859 2.40 / 460.26 2 3
4 13 830.96 24 14.92 1422 509 2.91 / 460.77 2 3
5 13 197.92 24 15.05 556 201 3.11 / 460.97 2 4
6 8 0.12 165 15.06 263 654 3.76 / 461.63 2 7
Average= 3.72
(KJ/cycle)

Cycle 122 GMT 21/ 1/2024 1:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 29 15.01 417 182 0.18 / 454.29 2 3
2 7 2003.96 31 14.83 2957 1359 1.54 / 455.65 2 3
3 13 1586.64 24 14.81 2426 862 2.40 / 456.52 2 3
4 13 809.08 24 14.92 1397 500 2.90 / 457.02 2 3
5 13 187.52 24 15.06 548 198 3.10 / 457.21 2 3
6 8 -0.04 165 15.07 262 651 3.75 / 457.87 2 10
Average= 3.72
(KJ/cycle)

Cycle 121 GMT 11/ 1/2024 6:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 29 14.99 415 180 0.18 / 450.49 2 3
2 7 2002.96 32 14.83 2945 1398 1.58 / 451.88 2 3
3 13 1586.32 24 14.80 2423 861 2.44 / 452.74 2 3
4 13 819.16 24 14.92 1410 505 2.94 / 453.25 2 3
5 13 197.96 24 15.05 567 205 3.15 / 453.45 2 4
6 8 0.08 165 15.07 265 659 3.81 / 454.11 2 3
Average= 3.72
(KJ/cycle)

Cycle 120 GMT 1/ 1/2024 11:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 15.01 409 178 0.18 / 446.61 2 3
2 7 2013.92 31 14.82 2959 1359 1.54 / 447.97 2 3
3 13 1588.80 24 14.81 2421 861 2.40 / 448.83 2 3
4 13 828.40 24 14.91 1416 507 2.90 / 449.34 2 4
5 13 203.68 24 15.05 574 207 3.11 / 449.55 2 5
6 13 16.56 24 15.10 294 107 3.22 / 449.65 2 3
7 8 0.00 165 15.07 262 651 3.87 / 450.31 2 5
Average= 3.72
(KJ/cycle)

Cycle 119 GMT 22/12/2023 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 29 15.01 415 181 0.18 / 442.82 2 3
2 7 2004.28 32 14.82 2944 1396 1.58 / 444.22 2 3
3 13 1596.84 24 14.82 2424 862 2.44 / 445.08 2 5
4 13 828.48 24 14.91 1414 506 2.94 / 445.59 2 4
5 13 202.48 24 15.06 569 206 3.15 / 445.79 2 4
6 8 0.16 165 15.06 259 644 3.79 / 446.44 2 9
Average= 3.72
(KJ/cycle)

Cycle 118 GMT 12/12/2023 21:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 14.99 418 182 0.18 / 439.05 2 3
2 7 2004.68 31 14.83 2946 1354 1.54 / 440.41 2 3
3 13 1591.24 24 14.81 2423 861 2.40 / 441.27 2 3
4 13 842.68 24 14.91 1436 514 2.91 / 441.78 2 3
5 13 200.60 24 15.05 569 206 3.12 / 441.99 2 4
6 8 0.04 165 15.07 263 654 3.77 / 442.64 2 7
Average= 3.72
(KJ/cycle)

Cycle 117 GMT 3/12/2023 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 29 15.01 409 178 0.18 / 435.15 2 3
2 7 2005.96 31 14.84 2956 1360 1.54 / 436.51 2 3
3 13 1605.64 24 14.81 2450 871 2.41 / 437.38 2 3
4 13 848.12 24 14.92 1444 517 2.93 / 437.90 2 3
5 13 219.60 24 15.05 593 214 3.14 / 438.11 2 3
6 13 21.84 24 15.09 299 108 3.25 / 438.22 2 4
7 8 0.08 165 15.06 261 649 3.90 / 438.87 2 10
Average= 3.72
(KJ/cycle)

Cycle 116 GMT 23/11/2023 7:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 15.01 417 182 0.18 / 431.38 2 3
2 7 2011.84 31 14.83 2964 1363 1.54 / 432.74 2 3
3 13 1588.32 24 14.82 2422 861 2.41 / 433.60 2 3
4 13 839.68 24 14.93 1435 514 2.92 / 434.11 2 3
5 13 201.76 24 15.07 568 205 3.13 / 434.32 2 4
6 8 0.12 165 15.08 263 654 3.78 / 434.97 2 6
Average= 3.72
(KJ/cycle)

Cycle 115 GMT 13/11/2023 12:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 29 14.99 412 179 0.18 / 427.60 2 3
2 7 2004.32 31 14.83 2947 1355 1.53 / 428.96 2 3
3 13 1603.04 24 14.81 2440 867 2.40 / 429.83 2 3
4 13 828.52 24 14.92 1420 508 2.91 / 430.33 2 3
5 13 193.44 24 15.07 555 201 3.11 / 430.54 2 3
6 8 0.16 165 15.07 265 659 3.77 / 431.19 2 4
Average= 3.72
(KJ/cycle)

Cycle 114 GMT 3/11/2023 17:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 15.00 407 177 0.18 / 423.69 2 3
2 7 2007.96 31 14.83 2962 1362 1.54 / 425.05 2 3
3 13 1593.08 24 14.81 2420 860 2.40 / 425.91 2 3
4 13 843.32 24 14.93 1437 515 2.91 / 426.43 2 3
5 13 213.28 24 15.06 586 212 3.13 / 426.64 2 3
6 13 40.36 24 15.09 333 121 3.25 / 426.76 2 4
7 8 0.04 165 15.07 267 664 3.91 / 427.42 2 5
Average= 3.72
(KJ/cycle)

Cycle 113 GMT 24/10/2023 22:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 29 15.00 406 177 0.18 / 419.85 2 2
2 7 2007.68 31 14.84 2955 1359 1.54 / 421.21 2 3
3 13 1580.64 24 14.82 2407 856 2.39 / 422.07 2 3
4 13 836.08 24 14.93 1421 509 2.90 / 422.58 2 4
5 13 147.40 24 15.08 489 177 3.08 / 422.75 2 3
6 13 32.20 24 15.10 314 114 3.19 / 422.87 2 5
7 8 0.04 165 15.07 260 647 3.84 / 423.51 2 13
Average= 3.72
(KJ/cycle)

Cycle 112 GMT 15/10/2023 3:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 29 15.00 411 179 0.18 / 415.99 2 2
2 7 2009.96 31 14.83 2948 1355 1.53 / 417.35 2 3
3 13 1600.80 24 14.81 2428 863 2.40 / 418.21 2 3
4 13 828.96 24 14.92 1414 506 2.90 / 418.72 2 3
5 13 196.08 24 15.06 561 203 3.11 / 418.92 2 3
6 13 17.84 24 15.09 292 106 3.21 / 419.02 2 3
7 8 0.00 165 15.06 262 651 3.86 / 419.68 2 5
Average= 3.71
(KJ/cycle)

Cycle 111 GMT 5/10/2023 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 29 15.01 404 176 0.18 / 412.12 2 3
2 7 2008.48 31 14.84 2941 1353 1.53 / 413.48 2 2
3 13 1589.96 24 14.82 2420 861 2.39 / 414.34 2 3
4 13 829.76 24 14.92 1415 507 2.90 / 414.84 2 3
5 13 199.04 24 15.06 567 205 3.10 / 415.05 2 4
6 13 20.40 24 15.09 298 108 3.21 / 415.16 2 2
7 8 0.08 165 15.06 264 656 3.87 / 415.81 2 11
Average= 3.71
(KJ/cycle)

Cycle 110 GMT 25/ 9/2023 13:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 29 15.01 409 178 0.18 / 408.27 2 2
2 7 2012.36 31 14.83 2952 1357 1.54 / 409.62 2 3
3 13 1600.40 24 14.82 2417 860 2.39 / 410.48 2 3
4 13 836.24 24 14.92 1423 510 2.90 / 410.99 2 3
5 13 199.12 24 15.05 561 203 3.11 / 411.19 2 3
6 13 20.12 24 15.09 296 107 3.21 / 411.30 2 3
7 8 0.00 165 15.06 260 646 3.86 / 411.95 2 10
Average= 3.71
(KJ/cycle)

Cycle 109 GMT 15/ 9/2023 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 29 15.00 407 177 0.18 / 404.52 2 3
2 7 2004.08 31 14.85 2951 1358 1.54 / 405.88 2 3
3 13 1589.16 24 14.82 2419 860 2.40 / 406.74 2 3
4 13 827.12 24 14.94 1413 507 2.90 / 407.24 2 4
5 13 195.48 24 15.07 553 200 3.10 / 407.44 2 4
6 8 0.16 165 15.08 259 644 3.75 / 408.09 2 7
Average= 3.71
(KJ/cycle)

Cycle 108 GMT 5/ 9/2023 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 29 15.01 401 175 0.17 / 400.74 2 3
2 7 2007.32 31 14.85 2942 1354 1.53 / 402.09 2 3
3 13 1589.24 24 14.83 2418 861 2.39 / 402.95 2 3
4 13 944.68 24 14.90 1566 560 2.95 / 403.51 2 3
5 13 159.64 24 15.08 507 183 3.13 / 403.70 2 4
6 8 0.00 165 15.09 259 645 3.78 / 404.34 2 10
Average= 3.71
(KJ/cycle)

Cycle 107 GMT 27/ 8/2023 4:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 15.03 411 179 0.18 / 397.01 2 3
2 7 2010.56 32 14.82 2938 1393 1.57 / 398.40 2 3
3 13 1475.32 24 14.82 2274 809 2.38 / 399.21 2 3
4 13 875.12 24 14.89 1475 527 2.91 / 399.74 2 3
5 13 152.52 24 15.06 496 179 3.09 / 399.92 2 3
6 8 0.04 165 15.07 259 644 3.73 / 400.56 2 9
Average= 3.71
(KJ/cycle)

Cycle 106 GMT 17/ 8/2023 7: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 15.02 417 182 0.18 / 393.23 2 3
2 7 2008.80 31 14.84 2955 1359 1.54 / 394.59 2 3
3 13 1599.56 24 14.83 2432 866 2.41 / 395.46 2 3
4 13 843.08 24 14.93 1434 514 2.92 / 395.97 2 3
5 13 204.88 24 15.07 574 208 3.13 / 396.18 2 4
6 8 0.16 165 15.09 262 652 3.78 / 396.83 2 11
Average= 3.71
(KJ/cycle)

Cycle 105 GMT 7/ 8/2023 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 15.00 412 179 0.18 / 389.44 2 3
2 7 2010.48 31 14.84 2960 1362 1.54 / 390.81 2 3
3 13 1596.56 24 14.82 2436 866 2.41 / 391.67 2 3
4 13 844.36 24 14.93 1436 515 2.92 / 392.19 2 3
5 13 204.92 24 15.07 570 206 3.13 / 392.39 2 3
6 8 0.04 165 15.08 264 657 3.78 / 393.05 2 7
Average= 3.71
(KJ/cycle)

Cycle 104 GMT 28/ 7/2023 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 29 15.02 408 178 0.18 / 385.65 2 3
2 7 2012.68 31 14.83 2956 1359 1.54 / 387.01 2 2
3 13 1613.64 24 14.82 2454 873 2.41 / 387.89 2 4
4 13 843.64 24 14.94 1441 517 2.93 / 388.40 2 4
5 13 213.52 24 15.06 577 209 3.13 / 388.61 2 4
6 8 0.08 165 15.08 263 654 3.79 / 389.27 2 8
Average= 3.71
(KJ/cycle)

Cycle 103 GMT 18/ 7/2023 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 29 15.04 415 181 0.18 / 381.88 2 3
2 7 2003.44 31 14.85 2949 1358 1.54 / 383.24 2 3
3 13 1596.84 24 14.84 2434 867 2.41 / 384.10 2 3
4 13 823.04 24 14.93 1415 507 2.91 / 384.61 2 4
5 13 193.08 24 15.07 557 201 3.11 / 384.81 2 3
6 8 0.00 165 15.08 267 664 3.78 / 385.48 2 7
Average= 3.71
(KJ/cycle)

Cycle 102 GMT 8/ 7/2023 16:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 29 15.01 412 179 0.18 / 378.23 2 3
2 7 2007.88 31 14.84 2956 1360 1.54 / 379.59 2 3
3 13 1473.44 24 14.84 2268 808 2.35 / 380.40 2 3
4 13 748.68 24 14.95 1311 470 2.82 / 380.87 2 3
5 13 150.04 24 15.09 494 179 3.00 / 381.05 2 3
6 8 0.08 165 15.09 262 652 3.65 / 381.70 2 6
Average= 3.71
(KJ/cycle)

Cycle 101 GMT 28/ 6/2023 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 15.03 412 180 0.18 / 374.36 2 3
2 7 2011.20 31 14.84 2952 1358 1.54 / 375.71 2 3
3 13 1602.08 24 14.81 2432 864 2.40 / 376.58 2 3
4 13 830.44 24 14.92 1418 508 2.91 / 377.09 2 4
5 13 191.12 24 15.07 553 200 3.11 / 377.29 2 3
6 13 17.56 24 15.10 297 108 3.22 / 377.39 2 3
7 8 0.00 165 15.07 264 656 3.87 / 378.05 2 6
Average= 3.71
(KJ/cycle)

Cycle 100 GMT 18/ 6/2023 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 29 15.03 405 177 0.18 / 370.54 2 3
2 7 2005.24 31 14.85 2946 1356 1.53 / 371.90 2 3
3 13 1727.32 24 14.81 2604 926 2.46 / 372.82 2 3
4 13 796.72 24 14.95 1375 493 2.95 / 373.32 2 3
5 13 187.48 24 15.09 545 197 3.15 / 373.52 2 4
6 8 0.12 165 15.10 265 660 3.81 / 374.18 2 10
Average= 3.70
(KJ/cycle)

Cycle 99 GMT 8/ 6/2023 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 29 15.02 416 181 0.18 / 366.82 2 3
2 7 2009.40 31 14.86 2950 1359 1.54 / 368.18 2 3
3 13 1490.16 24 14.85 2290 816 2.36 / 369.00 2 3
4 13 885.08 24 14.92 1490 534 2.89 / 369.53 2 3
5 13 158.00 24 15.08 502 182 3.07 / 369.71 2 3
6 8 0.16 165 15.09 262 652 3.72 / 370.37 2 7
Average= 3.70
(KJ/cycle)

Cycle 98 GMT 30/ 5/2023 1:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 29 15.03 414 180 0.18 / 362.89 2 3
2 7 2002.96 32 14.84 2946 1399 1.58 / 364.29 2 3
3 13 1719.48 24 14.80 2579 916 2.50 / 365.21 2 3
4 13 915.64 24 14.91 1525 546 3.04 / 365.75 2 3
5 13 259.24 24 15.05 646 233 3.27 / 365.99 2 4
6 8 0.12 165 15.09 263 655 3.93 / 366.64 2 8
Average= 3.70
(KJ/cycle)

Cycle 97 GMT 20/ 5/2023 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 15.04 408 178 0.18 / 359.13 2 3
2 7 2008.24 31 14.86 2954 1361 1.54 / 360.49 2 3
3 13 1592.72 24 14.83 2423 862 2.40 / 361.35 2 3
4 13 826.88 24 14.95 1413 507 2.91 / 361.86 2 3
5 13 189.80 24 15.09 551 200 3.11 / 362.06 2 4
6 8 0.04 165 15.10 263 655 3.76 / 362.71 2 7
Average= 3.70
(KJ/cycle)

Cycle 96 GMT 10/ 5/2023 5:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 15.04 406 177 0.18 / 355.35 2 3
2 7 2007.20 32 14.86 2940 1398 1.58 / 356.75 2 3
3 13 1580.04 24 14.84 2404 856 2.43 / 357.60 2 3
4 13 822.00 24 14.95 1407 505 2.94 / 358.11 2 3
5 13 190.48 24 15.09 539 195 3.13 / 358.30 2 3
6 8 0.04 165 15.10 260 648 3.78 / 358.95 2 10
Average= 3.70
(KJ/cycle)

Cycle 95 GMT 30/ 4/2023 8:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 29 15.03 406 177 0.18 / 351.67 2 3
2 7 2007.64 31 14.86 2948 1358 1.53 / 353.02 2 3
3 13 1595.84 24 14.84 2421 862 2.40 / 353.89 2 4
4 13 713.72 24 14.97 1260 453 2.85 / 354.34 2 4
5 13 160.00 24 15.09 504 183 3.03 / 354.52 2 3
6 8 0.00 165 15.10 261 650 3.68 / 355.17 2 6
Average= 3.70
(KJ/cycle)

Cycle 94 GMT 20/ 4/2023 10:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 29 15.03 414 180 0.18 / 347.92 2 3
2 7 2003.04 31 14.84 2942 1353 1.53 / 349.27 2 3
3 13 1591.84 24 14.82 2414 859 2.39 / 350.13 2 3
4 13 827.36 24 14.94 1408 505 2.90 / 350.63 2 3
5 13 187.32 24 15.08 546 198 3.09 / 350.83 2 3
6 8 0.00 165 15.09 264 657 3.75 / 351.49 2 8
Average= 3.70
(KJ/cycle)

Cycle 93 GMT 10/ 4/2023 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 29 15.03 406 177 0.18 / 344.13 2 3
2 7 2002.96 32 14.87 2936 1397 1.57 / 345.53 2 3
3 13 1579.48 24 14.85 2401 856 2.43 / 346.39 2 4
4 13 812.24 24 14.96 1396 501 2.93 / 346.89 2 3
5 13 192.76 24 15.09 549 199 3.13 / 347.09 2 3
6 8 0.00 165 15.11 261 651 3.78 / 347.74 2 6
Average= 3.70
(KJ/cycle)

Cycle 92 GMT 31/ 3/2023 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 15.03 407 177 0.18 / 340.41 2 3
2 7 2010.80 31 14.87 2951 1360 1.54 / 341.78 2 3
3 13 1477.92 24 14.87 2268 809 2.35 / 342.58 2 3
4 13 893.72 24 14.94 1502 539 2.89 / 343.12 2 3
5 13 155.88 24 15.09 503 182 3.07 / 343.31 2 3
6 8 0.12 165 15.10 261 650 3.72 / 343.96 2 9
Average= 3.70
(KJ/cycle)

Cycle 91 GMT 21/ 3/2023 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 15.06 402 176 0.18 / 336.67 2 3
2 7 2012.52 31 14.85 2952 1359 1.53 / 338.03 2 3
3 13 1597.76 24 14.83 2426 863 2.40 / 338.89 2 3
4 13 819.76 24 14.94 1402 503 2.90 / 339.40 2 3
5 13 185.00 24 15.08 538 195 3.10 / 339.59 2 3
6 8 -0.08 165 15.09 260 647 3.74 / 340.24 2 8
Average= 3.70
(KJ/cycle)

Cycle 90 GMT 11/ 3/2023 19:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 29 15.04 411 179 0.18 / 332.97 2 3
2 7 2004.68 31 14.88 2948 1360 1.54 / 334.32 2 3
3 13 1477.96 24 14.86 2273 811 2.35 / 335.14 2 3
4 13 874.32 24 14.94 1474 529 2.88 / 335.66 2 4
5 13 148.96 24 15.11 489 177 3.06 / 335.84 2 3
6 8 0.04 165 15.11 262 653 3.71 / 336.49 2 8
Average= 3.70
(KJ/cycle)

Cycle 89 GMT 1/ 3/2023 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 29 15.04 413 180 0.18 / 329.21 2 3
2 7 2014.24 31 14.87 2969 1369 1.55 / 330.58 2 3
3 13 1598.16 24 14.83 2417 860 2.41 / 331.44 2 3
4 13 820.88 24 14.94 1404 503 2.91 / 331.95 2 3
5 13 190.68 24 15.09 546 198 3.11 / 332.14 2 4
6 8 0.08 165 15.09 258 642 3.75 / 332.79 2 7
Average= 3.70
(KJ/cycle)

Cycle 88 GMT 20/ 2/2023 0:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 29 15.07 418 183 0.18 / 325.31 2 3
2 7 2004.88 31 14.87 2948 1359 1.54 / 326.67 2 3
3 13 1600.96 24 14.84 2440 869 2.41 / 327.54 2 3
4 13 841.20 24 14.96 1427 512 2.92 / 328.05 2 4
5 13 214.64 24 15.09 582 211 3.13 / 328.27 2 3
6 8 -0.04 165 15.11 261 651 3.78 / 328.92 2 6
7 14 -0.04 30 15.09 259 117 3.90 / 329.03 3 9
Average= 3.70
(KJ/cycle)

Cycle 87 GMT 10/ 2/2023 2:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 29 15.05 412 180 0.18 / 321.56 2 3
2 7 2011.00 31 14.87 2951 1360 1.54 / 322.92 2 3
3 13 1583.72 24 14.84 2410 858 2.40 / 323.77 2 4
4 13 826.84 24 14.96 1410 506 2.90 / 324.28 2 4
5 13 197.32 24 15.09 554 201 3.11 / 324.48 2 3
6 8 0.12 165 15.11 261 651 3.76 / 325.13 2 8
Average= 3.69
(KJ/cycle)

Cycle 86 GMT 31/ 1/2023 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 29 15.04 406 177 0.18 / 317.81 2 3
2 7 2010.24 31 14.87 2945 1358 1.53 / 319.16 2 3
3 13 1483.72 24 14.87 2287 816 2.35 / 319.98 2 3
4 13 869.40 24 14.94 1470 527 2.88 / 320.51 2 3
5 13 213.92 24 15.08 581 210 3.09 / 320.72 2 4
6 8 -0.08 165 15.10 264 658 3.75 / 321.38 2 7
Average= 3.69
(KJ/cycle)

Cycle 85 GMT 21/ 1/2023 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 29 15.07 408 178 0.18 / 314.05 2 3
2 7 2004.76 31 14.86 2945 1357 1.53 / 315.41 2 3
3 13 1601.00 24 14.85 2426 865 2.40 / 316.27 2 3
4 13 825.00 24 14.96 1408 506 2.91 / 316.78 2 3
5 13 194.20 24 15.10 556 201 3.11 / 316.98 2 4
6 8 0.12 165 15.11 260 648 3.75 / 317.63 2 5
Average= 3.69
(KJ/cycle)

Cycle 84 GMT 11/ 1/2023 9:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 29 15.05 410 179 0.18 / 310.25 2 3
2 7 2003.16 31 14.87 2951 1360 1.54 / 311.61 2 3
3 13 1726.16 24 14.85 2597 926 2.46 / 312.54 2 3
4 13 789.16 24 14.98 1369 492 2.96 / 313.03 2 5
5 13 190.04 24 15.12 550 200 3.16 / 313.23 2 3
6 8 0.12 165 15.12 259 646 3.80 / 313.87 2 8
Average= 3.69
(KJ/cycle)

Cycle 83 GMT 1/ 1/2023 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 29 15.08 413 181 0.18 / 306.50 2 3
2 7 2010.88 31 14.90 2950 1363 1.54 / 307.86 2 3
3 13 1468.80 24 14.88 2265 809 2.35 / 308.67 2 3
4 13 868.92 24 14.97 1471 529 2.88 / 309.20 2 4
5 13 220.68 24 15.10 591 214 3.09 / 309.41 2 4
6 8 0.04 165 15.13 265 662 3.76 / 310.07 2 7
Average= 3.69
(KJ/cycle)

Cycle 82 GMT 22/12/2022 14:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 29 15.06 405 177 0.18 / 302.73 2 3
2 7 2009.40 31 14.88 2974 1372 1.55 / 304.10 2 3
3 13 1581.20 24 14.87 2410 860 2.41 / 304.96 2 3
4 13 824.04 24 14.98 1410 507 2.92 / 305.47 2 3
5 13 182.52 24 15.12 538 195 3.11 / 305.66 2 3
6 8 0.12 165 15.14 262 655 3.77 / 306.32 2 6
Average= 3.69
(KJ/cycle)

Cycle 81 GMT 12/12/2022 17:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 29 15.07 408 178 0.18 / 298.98 2 3
2 7 2003.04 31 14.86 2934 1352 1.53 / 300.33 2 3
3 13 1582.64 24 14.85 2409 859 2.39 / 301.19 2 3
4 13 828.72 24 14.96 1416 508 2.90 / 301.70 2 3
5 13 202.16 24 15.10 563 204 3.10 / 301.90 2 3
6 8 0.08 165 15.12 259 646 3.75 / 302.55 2 7
Average= 3.69
(KJ/cycle)

Cycle 80 GMT 2/12/2022 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 29 15.06 402 176 0.18 / 295.16 2 3
2 7 2012.80 31 14.88 2954 1363 1.54 / 296.52 2 3
3 13 1741.48 24 14.85 2613 931 2.47 / 297.46 2 3
4 13 805.32 24 14.99 1388 499 2.97 / 297.95 2 5
5 13 190.88 24 15.12 549 199 3.17 / 298.15 2 3
6 8 0.04 165 15.13 260 649 3.82 / 298.80 2 7
Average= 3.69
(KJ/cycle)

Cycle 79 GMT 22/11/2022 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 29 15.08 409 179 0.18 / 291.42 2 3
2 7 2004.08 31 14.88 2949 1360 1.54 / 292.78 2 3
3 13 1579.28 24 14.86 2403 857 2.40 / 293.64 2 3
4 13 807.60 24 14.98 1391 500 2.90 / 294.14 2 4
5 13 180.48 24 15.12 534 194 3.09 / 294.33 2 4
6 8 0.04 165 15.12 261 651 3.74 / 294.99 2 9
Average= 3.69
(KJ/cycle)

Cycle 78 GMT 13/11/2022 0:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 29 15.08 405 177 0.18 / 287.67 2 3
2 7 2003.08 32 14.88 2941 1400 1.58 / 289.07 2 3
3 13 1582.00 24 14.86 2407 858 2.44 / 289.93 2 3
4 13 821.40 24 14.98 1404 505 2.94 / 290.43 2 3
5 13 127.04 24 15.14 457 166 3.11 / 290.60 2 3
6 8 0.08 165 15.14 259 647 3.75 / 291.24 2 13
Average= 3.69
(KJ/cycle)

Cycle 77 GMT 3/11/2022 2:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 15.08 409 179 0.18 / 283.90 2 3
2 7 2003.68 31 14.89 2947 1360 1.54 / 285.26 2 2
3 13 1599.68 24 14.86 2429 866 2.41 / 286.13 2 3
4 13 826.28 24 14.98 1412 508 2.91 / 286.64 2 4
5 13 187.68 24 15.13 547 199 3.11 / 286.84 2 4
6 8 0.08 165 15.14 262 655 3.77 / 287.49 2 4
Average= 3.69
(KJ/cycle)

Cycle 76 GMT 24/10/2022 5:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 29 15.07 404 177 0.18 / 280.15 2 3
2 7 2005.24 31 14.87 2956 1363 1.54 / 281.51 2 3
3 13 1579.84 24 14.87 2407 859 2.40 / 282.37 2 3
4 13 806.96 24 14.98 1386 498 2.90 / 282.87 2 3
5 13 182.84 24 15.12 540 196 3.09 / 283.06 2 3
6 8 0.00 165 15.14 265 662 3.75 / 283.72 2 5
Average= 3.68
(KJ/cycle)

Cycle 75 GMT 14/10/2022 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 29 15.09 412 180 0.18 / 276.27 2 3
2 7 2006.68 31 14.89 2962 1367 1.55 / 277.64 2 3
3 13 1589.96 24 14.86 2422 864 2.41 / 278.50 2 3
4 13 818.80 24 14.99 1405 505 2.92 / 279.01 2 3
5 13 185.16 24 15.13 547 199 3.12 / 279.20 2 3
6 13 17.52 24 15.16 293 107 3.22 / 279.31 2 3
7 8 -0.08 165 15.14 264 659 3.88 / 279.97 2 9
Average= 3.68
(KJ/cycle)

Cycle 74 GMT 4/10/2022 9:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 29 15.08 399 174 0.17 / 272.41 2 3
2 7 2010.84 31 14.89 2953 1363 1.54 / 273.77 2 3
3 13 1607.56 24 14.87 2444 872 2.41 / 274.64 2 3
4 13 824.08 24 15.00 1407 507 2.92 / 275.15 2 3
5 13 127.16 24 15.16 467 170 3.09 / 275.32 2 3
6 13 29.92 24 15.17 313 114 3.20 / 275.43 2 3
7 8 0.00 165 15.15 263 657 3.86 / 276.09 2 8
Average= 3.68
(KJ/cycle)

Cycle 73 GMT 24/ 9/2022 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 29 15.11 409 179 0.18 / 268.45 2 3
2 7 2007.64 31 14.89 2943 1358 1.54 / 269.81 2 4
3 13 1587.88 24 14.88 2415 862 2.40 / 270.67 2 3
4 13 800.56 24 15.00 1367 492 2.89 / 271.16 2 5
5 13 179.60 24 15.15 536 195 3.09 / 271.36 2 3
6 13 15.48 24 15.17 287 104 3.19 / 271.46 2 3
7 8 0.00 165 15.15 260 650 3.84 / 272.11 2 11
8 14 0.00 30 15.13 260 118 3.96 / 272.23 2 9
Average= 3.68
(KJ/cycle)

Cycle 72 GMT 14/ 9/2022 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 29 15.10 408 179 0.18 / 264.68 2 3
2 7 2007.56 32 14.88 2936 1398 1.58 / 266.07 2 3
3 13 1589.96 24 14.87 2414 862 2.44 / 266.93 2 3
4 13 801.36 24 14.99 1379 496 2.93 / 267.43 2 3
5 13 179.20 24 15.14 530 193 3.13 / 267.62 2 4
6 8 0.12 165 15.17 259 648 3.78 / 268.27 2 7
Average= 3.67
(KJ/cycle)

Cycle 71 GMT 4/ 9/2022 17: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 15.11 399 175 0.17 / 260.80 2 3
2 7 2011.56 31 14.91 2959 1368 1.54 / 262.17 2 3
3 13 1587.56 24 14.88 2417 863 2.41 / 263.03 2 3
4 13 822.68 24 15.01 1409 508 2.91 / 263.54 2 3
5 13 198.40 24 15.15 561 204 3.12 / 263.74 2 3
6 13 18.08 24 15.18 294 107 3.22 / 263.85 2 3
7 8 0.04 165 15.15 259 647 3.87 / 264.50 2 11
Average= 3.67
(KJ/cycle)

Cycle 70 GMT 25/ 8/2022 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 29 15.10 403 176 0.18 / 256.98 2 3
2 7 2007.56 32 14.90 2949 1406 1.58 / 258.39 2 3
3 13 1591.00 24 14.89 2431 869 2.45 / 259.26 2 3
4 13 830.72 24 15.00 1418 510 2.96 / 259.77 2 3
5 13 190.00 24 15.16 548 199 3.16 / 259.97 2 3
6 8 0.08 165 15.17 262 656 3.82 / 260.62 2 9
Average= 3.67
(KJ/cycle)

Cycle 69 GMT 15/ 8/2022 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 29 15.10 406 178 0.18 / 253.10 2 3
2 7 2010.76 31 14.89 2951 1362 1.54 / 254.46 2 3
3 13 1601.88 24 14.88 2437 870 2.41 / 255.33 2 4
4 13 844.40 24 15.00 1435 517 2.93 / 255.85 2 4
5 13 215.96 24 15.13 585 212 3.14 / 256.06 2 3
6 13 17.60 24 15.18 289 105 3.24 / 256.16 2 3
7 8 -0.04 165 15.15 258 645 3.89 / 256.81 2 9
Average= 3.67
(KJ/cycle)

Cycle 68 GMT 6/ 8/2022 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 28 15.10 405 171 0.17 / 249.33 2 3
2 7 2003.44 31 14.90 2940 1358 1.53 / 250.69 2 3
3 13 1590.36 24 14.89 2417 864 2.39 / 251.56 2 3
4 13 833.16 24 15.00 1419 511 2.90 / 252.07 2 4
5 13 191.60 24 15.16 553 201 3.11 / 252.27 2 4
6 8 0.04 165 15.17 260 651 3.76 / 252.92 2 6
Average= 3.67
(KJ/cycle)

Cycle 67 GMT 27/ 7/2022 2:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 28 15.12 404 171 0.17 / 245.62 2 3
2 7 2003.32 31 14.89 2939 1357 1.53 / 246.98 2 3
3 13 1468.60 24 14.90 2267 811 2.34 / 247.79 2 3
4 13 852.88 24 14.99 1449 521 2.86 / 248.31 2 4
5 13 202.68 24 15.15 565 205 3.07 / 248.51 2 3
6 8 0.00 165 15.16 259 648 3.71 / 249.16 2 8
Average= 3.66
(KJ/cycle)

Cycle 66 GMT 17/ 7/2022 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 15.13 413 175 0.17 / 241.86 2 3
2 7 2003.76 31 14.92 2942 1361 1.54 / 243.23 2 3
3 13 1591.12 24 14.89 2423 866 2.40 / 244.09 2 3
4 13 828.20 24 15.01 1419 511 2.91 / 244.60 2 3
5 13 198.04 24 15.16 560 204 3.12 / 244.81 2 4
6 8 0.04 165 15.18 257 644 3.76 / 245.45 2 6
Average= 3.66
(KJ/cycle)

Cycle 65 GMT 7/ 7/2022 7: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 15.12 410 174 0.17 / 238.14 2 3
2 7 2009.88 31 14.90 2967 1370 1.54 / 239.51 2 3
3 13 1608.48 24 14.88 2452 876 2.42 / 240.39 2 3
4 13 728.16 24 15.03 1283 463 2.88 / 240.85 2 4
5 13 141.52 24 15.18 487 177 3.06 / 241.03 2 3
6 8 0.04 165 15.18 263 659 3.72 / 241.69 2 11
Average= 3.66
(KJ/cycle)

Cycle 64 GMT 27/ 6/2022 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 28 15.12 412 174 0.17 / 234.37 2 3
2 7 2004.28 31 14.91 2945 1361 1.54 / 235.73 2 3
3 13 1581.92 24 14.90 2411 862 2.40 / 236.59 2 3
4 13 833.96 24 15.02 1428 515 2.91 / 237.11 2 3
5 13 208.68 24 15.17 574 209 3.12 / 237.31 2 3
6 8 0.04 165 15.19 262 657 3.78 / 237.97 2 9
Average= 3.66
(KJ/cycle)

Cycle 63 GMT 17/ 6/2022 11:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 15.14 400 170 0.17 / 230.60 2 3
2 7 2005.80 31 14.90 2947 1361 1.53 / 231.96 2 3
3 13 1582.48 24 14.88 2404 859 2.39 / 232.82 2 3
4 13 825.68 24 15.01 1409 508 2.90 / 233.33 2 3
5 13 194.04 24 15.16 559 203 3.10 / 233.53 2 4
6 8 0.08 165 15.18 263 659 3.76 / 234.19 2 8
Average= 3.66
(KJ/cycle)

Cycle 62 GMT 7/ 6/2022 13:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 28 15.14 407 173 0.17 / 226.84 2 3
2 7 2010.68 31 14.91 2967 1371 1.54 / 228.21 2 3
3 13 1598.60 24 14.90 2435 871 2.41 / 229.08 2 4
4 13 831.00 24 15.02 1421 512 2.93 / 229.59 2 4
5 13 172.88 24 15.19 525 191 3.12 / 229.78 2 3
6 8 0.04 165 15.20 260 652 3.77 / 230.43 2 6
Average= 3.66
(KJ/cycle)

Cycle 61 GMT 28/ 5/2022 16:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 15.15 403 171 0.17 / 223.07 2 3
2 7 2011.84 31 14.89 2961 1367 1.54 / 224.44 2 2
3 13 1593.20 24 14.89 2424 866 2.40 / 225.30 2 3
4 13 815.56 24 15.01 1394 502 2.91 / 225.81 2 4
5 13 180.44 24 15.17 542 197 3.10 / 226.00 2 3
6 8 -0.12 165 15.18 263 659 3.76 / 226.66 2 7
Average= 3.66
(KJ/cycle)

Cycle 60 GMT 18/ 5/2022 18:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 28 15.13 409 173 0.17 / 219.39 2 3
2 7 2006.52 32 14.90 2950 1407 1.58 / 220.79 2 3
3 13 1466.96 24 14.90 2256 807 2.39 / 221.60 2 3
4 13 735.00 24 15.05 1290 466 2.85 / 222.06 2 3
5 13 146.40 24 15.19 493 180 3.03 / 222.24 2 4
6 8 0.00 165 15.19 262 657 3.69 / 222.90 2 9
Average= 3.65
(KJ/cycle)

Cycle 59 GMT 8/ 5/2022 20:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 28 15.14 408 173 0.17 / 215.56 2 3
2 7 2012.72 31 14.90 2955 1365 1.54 / 216.92 2 3
3 13 1606.92 24 14.88 2440 871 2.41 / 217.79 2 4
4 13 972.20 24 14.97 1603 576 2.99 / 218.37 2 3
5 13 173.00 24 15.17 525 191 3.18 / 218.56 2 3
6 8 0.08 165 15.19 260 652 3.83 / 219.21 2 13
Average= 3.65
(KJ/cycle)

Cycle 58 GMT 28/ 4/2022 23: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 28 15.14 396 168 0.17 / 211.81 2 3
2 7 2005.96 31 14.91 2940 1359 1.53 / 213.17 2 3
3 13 1589.24 24 14.90 2413 863 2.39 / 214.03 2 3
4 13 824.92 24 15.03 1408 508 2.90 / 214.54 2 4
5 13 185.84 24 15.19 540 197 3.09 / 214.74 2 3
6 8 0.00 165 15.20 257 645 3.74 / 215.38 2 7
Average= 3.65
(KJ/cycle)

Cycle 57 GMT 19/ 4/2022 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 28 15.15 401 170 0.17 / 208.17 2 3
2 7 2005.04 31 14.91 2937 1358 1.53 / 209.53 2 3
3 13 1474.80 24 14.92 2263 810 2.34 / 210.34 2 3
4 13 759.48 24 15.04 1322 477 2.82 / 210.82 2 3
5 13 153.96 24 15.20 498 182 3.00 / 211.00 2 3
6 8 0.00 165 15.20 257 645 3.64 / 211.65 2 6
Average= 3.65
(KJ/cycle)

Cycle 56 GMT 9/ 4/2022 3:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 28 15.15 401 170 0.17 / 204.45 2 3
2 7 2011.44 31 14.90 2940 1358 1.53 / 205.81 2 3
3 13 1477.84 24 14.91 2270 812 2.34 / 206.62 2 3
4 13 865.56 24 15.02 1457 525 2.87 / 207.14 2 4
5 13 209.64 24 15.19 576 210 3.08 / 207.35 2 4
6 8 -0.04 165 15.20 259 650 3.73 / 208.00 2 6
Average= 3.65
(KJ/cycle)

Cycle 55 GMT 30/ 3/2022 5:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 28 15.17 400 170 0.17 / 200.73 2 3
2 7 2006.12 31 14.91 2932 1355 1.53 / 202.08 2 3
3 13 1599.68 24 14.90 2432 870 2.39 / 202.95 2 3
4 13 831.36 24 15.03 1409 508 2.90 / 203.46 2 3
5 13 131.16 24 15.22 462 169 3.07 / 203.63 2 3
6 8 0.08 165 15.22 259 650 3.72 / 204.28 2 6
Average= 3.65
(KJ/cycle)

Cycle 54 GMT 20/ 3/2022 8: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 28 15.17 407 173 0.17 / 197.07 2 3
2 7 2007.20 31 14.91 2944 1361 1.53 / 198.43 2 3
3 13 1585.40 24 14.91 2406 861 2.39 / 199.29 2 3
4 13 704.60 24 15.08 1249 452 2.85 / 199.74 2 4
5 13 134.20 24 15.21 469 171 3.02 / 199.91 2 3
6 8 0.00 165 15.22 257 645 3.66 / 200.56 2 10
Average= 3.65
(KJ/cycle)

Cycle 53 GMT 10/ 3/2022 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 28 15.17 402 171 0.17 / 193.36 2 3
2 7 2005.04 31 14.92 2942 1361 1.53 / 194.72 2 3
3 13 1474.32 24 14.93 2267 812 2.34 / 195.53 2 3
4 13 899.00 24 15.02 1502 541 2.89 / 196.08 2 3
5 13 142.76 24 15.22 476 174 3.06 / 196.25 2 3
6 8 0.00 165 15.22 256 643 3.70 / 196.89 2 9
Average= 3.65
(KJ/cycle)

Cycle 52 GMT 28/ 2/2022 12:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 15.17 403 171 0.17 / 189.73 2 3
2 7 2007.08 31 14.92 2942 1361 1.53 / 191.09 2 3
3 13 1476.88 24 14.93 2269 813 2.34 / 191.91 2 3
4 13 737.52 24 15.08 1294 468 2.81 / 192.38 2 3
5 13 144.60 24 15.23 479 175 2.99 / 192.55 2 4
6 8 0.00 165 15.23 255 641 3.63 / 193.19 2 7
Average= 3.65
(KJ/cycle)

Cycle 51 GMT 18/ 2/2022 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 28 15.20 393 167 0.17 / 185.97 2 2
2 7 2009.32 31 14.93 2957 1369 1.54 / 187.34 2 3
3 13 1582.20 24 14.93 2408 863 2.40 / 188.20 2 3
4 13 832.48 24 15.04 1426 515 2.91 / 188.72 2 4
5 13 186.48 24 15.21 541 197 3.11 / 188.92 2 3
6 8 0.08 165 15.23 257 646 3.76 / 189.56 2 6
Average= 3.65
(KJ/cycle)

Cycle 50 GMT 8/ 2/2022 17: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 28 15.21 397 169 0.17 / 182.22 2 3
2 7 2007.20 31 14.94 2948 1365 1.53 / 183.58 2 3
3 13 1597.56 24 14.92 2419 866 2.40 / 184.45 2 3
4 13 828.56 24 15.06 1418 513 2.91 / 184.96 2 3
5 13 185.64 24 15.24 540 198 3.11 / 185.16 2 4
6 8 0.16 165 15.24 257 646 3.76 / 185.81 2 6
Average= 3.64
(KJ/cycle)

Cycle 49 GMT 29/ 1/2022 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 28 15.18 402 171 0.17 / 178.39 2 3
2 3 1017.60 1 15.25 1748 27 0.20 / 178.42 2 3
3 7 2006.32 31 14.93 2961 1370 1.57 / 179.79 2 3
4 13 1605.68 24 14.93 2446 876 2.44 / 180.67 2 3
5 13 954.96 24 15.05 1577 570 3.01 / 181.24 2 3
6 13 154.60 24 15.25 492 180 3.19 / 181.42 2 3
7 8 0.00 165 15.26 251 632 3.83 / 182.05 2 9
Average= 3.64
(KJ/cycle)

Cycle 48 GMT 19/ 1/2022 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 15.19 392 167 0.17 / 174.69 2 3
2 7 2012.80 32 14.93 2947 1408 1.57 / 176.10 2 3
3 13 1592.68 24 14.92 2419 866 2.44 / 176.96 2 4
4 13 700.20 24 15.11 1240 450 2.89 / 177.41 2 3
5 13 137.40 24 15.24 473 173 3.06 / 177.59 2 4
6 8 0.08 165 15.25 253 637 3.70 / 178.22 2 10
Average= 3.64
(KJ/cycle)

Cycle 47 GMT 9/ 1/2022 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 28 15.21 402 171 0.17 / 170.94 2 3
2 7 2008.56 31 14.96 2954 1370 1.54 / 172.31 2 3
3 13 1603.32 24 14.93 2435 873 2.41 / 173.18 2 3
4 13 858.88 24 15.07 1454 526 2.94 / 173.71 2 4
5 13 145.88 24 15.25 484 177 3.12 / 173.88 2 3
6 8 0.16 165 15.26 253 637 3.75 / 174.52 2 10
Average= 3.64
(KJ/cycle)

Cycle 46 GMT 31/12/2021 2: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 28 15.20 399 170 0.17 / 167.19 2 3
2 7 2002.84 31 14.94 2951 1367 1.54 / 168.55 2 3
3 13 1585.44 24 14.93 2408 863 2.40 / 169.42 2 3
4 13 806.96 24 15.08 1394 505 2.90 / 169.92 2 3
5 13 174.64 24 15.24 530 194 3.10 / 170.12 2 3
6 8 0.08 165 15.26 259 652 3.75 / 170.77 2 7
Average= 3.63
(KJ/cycle)

Cycle 45 GMT 21/12/2021 4:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 28 15.21 402 171 0.17 / 163.42 2 3
2 7 2008.36 31 14.95 2949 1367 1.54 / 164.79 2 3
3 13 1599.92 24 14.93 2439 874 2.41 / 165.66 2 3
4 13 829.20 24 15.08 1406 509 2.92 / 166.17 2 4
5 13 185.76 24 15.24 542 198 3.12 / 166.37 2 4
6 8 -0.08 165 15.26 258 650 3.77 / 167.02 2 9
Average= 3.63
(KJ/cycle)

Cycle 44 GMT 11/12/2021 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 28 15.22 404 172 0.17 / 159.67 2 3
2 7 2007.72 31 14.94 2949 1366 1.54 / 161.03 2 3
3 13 1579.56 24 14.94 2410 864 2.40 / 161.90 2 3
4 13 815.84 24 15.08 1406 509 2.91 / 162.41 2 3
5 13 177.48 24 15.24 533 195 3.11 / 162.60 2 4
6 8 0.04 165 15.26 258 650 3.76 / 163.25 2 7
Average= 3.63
(KJ/cycle)

Cycle 43 GMT 1/12/2021 9:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 28 15.21 389 166 0.17 / 155.88 2 3
2 7 2005.64 31 14.94 2966 1374 1.54 / 157.26 2 3
3 13 1731.08 24 14.91 2604 932 2.47 / 158.19 2 3
4 13 776.04 24 15.11 1344 487 2.96 / 158.68 2 3
5 13 162.36 24 15.26 506 185 3.14 / 158.86 2 3
6 8 0.12 165 15.28 251 633 3.78 / 159.49 2 9
Average= 3.62
(KJ/cycle)

Cycle 42 GMT 21/11/2021 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 28 15.21 388 165 0.17 / 152.20 2 3
2 7 2004.16 31 14.96 2947 1367 1.53 / 153.57 2 3
3 13 1474.04 24 14.97 2276 818 2.35 / 154.39 2 3
4 13 859.68 24 15.08 1456 527 2.88 / 154.91 2 3
5 13 130.08 24 15.27 459 168 3.04 / 155.08 2 3
6 8 0.08 165 15.28 252 635 3.68 / 155.72 2 7
Average= 3.62
(KJ/cycle)

Cycle 41 GMT 11/11/2021 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 28 15.20 397 169 0.17 / 148.34 2 3
2 7 2009.72 31 14.95 2972 1377 1.55 / 149.72 2 3
3 13 1578.36 24 14.96 2412 866 2.41 / 150.58 2 3
4 13 815.12 24 15.10 1393 505 2.92 / 151.09 2 4
5 13 174.48 24 15.26 523 192 3.11 / 151.28 2 3
6 8 0.04 165 15.27 254 640 3.75 / 151.92 2 4
7 14 0.04 30 15.25 254 116 3.86 / 152.04 3 10
Average= 3.62
(KJ/cycle)

Cycle 40 GMT 1/11/2021 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 28 15.22 397 169 0.17 / 144.52 2 3
2 7 2003.32 31 14.95 2938 1362 1.53 / 145.88 2 3
3 13 1571.52 24 14.96 2392 859 2.39 / 146.74 2 3
4 13 808.20 24 15.10 1386 502 2.89 / 147.24 2 4
5 13 174.24 24 15.27 522 191 3.08 / 147.43 2 3
6 13 16.12 24 15.30 280 103 3.19 / 147.54 2 3
7 8 -0.12 165 15.27 253 637 3.82 / 148.17 2 7
Average= 3.61
(KJ/cycle)

Cycle 39 GMT 22/10/2021 18:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 15.23 398 170 0.17 / 140.81 2 3
2 7 2004.60 32 14.95 2957 1415 1.58 / 142.22 2 3
3 13 1588.64 24 14.95 2415 867 2.45 / 143.09 2 3
4 13 697.08 24 15.14 1239 450 2.90 / 143.54 2 3
5 13 131.76 24 15.29 461 169 3.07 / 143.71 2 3
6 8 0.16 165 15.28 255 643 3.71 / 144.35 2 11
Average= 3.61
(KJ/cycle)

Cycle 38 GMT 12/10/2021 20:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 28 15.23 400 171 0.17 / 136.96 2 3
2 7 2006.04 31 14.97 2941 1365 1.54 / 138.32 2 3
3 13 1580.72 24 14.96 2399 861 2.40 / 139.18 2 3
4 13 812.60 24 15.11 1392 505 2.90 / 139.69 2 4
5 13 170.56 24 15.28 524 192 3.09 / 139.88 2 4
6 13 16.12 24 15.31 291 107 3.20 / 139.99 2 2
7 8 0.12 165 15.27 257 648 3.85 / 140.64 2 7
Average= 3.61
(KJ/cycle)

Cycle 37 GMT 2/10/2021 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 28 15.22 391 167 0.17 / 133.21 2 3
2 7 2002.72 31 14.96 2945 1366 1.53 / 134.58 2 3
3 13 1577.16 24 14.97 2404 864 2.40 / 135.44 2 4
4 13 802.04 24 15.13 1381 501 2.90 / 135.94 2 3
5 13 173.32 24 15.28 529 194 3.09 / 136.13 2 3
6 8 0.08 165 15.29 259 653 3.74 / 136.79 2 6
Average= 3.60
(KJ/cycle)

Cycle 36 GMT 23/ 9/2021 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 28 15.24 395 169 0.17 / 129.48 2 3
2 7 2004.08 31 14.97 2933 1361 1.53 / 130.84 2 3
3 13 1587.60 24 14.98 2418 869 2.40 / 131.71 2 3
4 13 790.00 24 15.13 1365 496 2.89 / 132.21 2 3
5 13 151.76 24 15.29 495 182 3.08 / 132.39 2 4
6 8 0.00 165 15.29 259 653 3.73 / 133.04 2 7
Average= 3.60
(KJ/cycle)

Cycle 35 GMT 13/ 9/2021 3:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 15.26 400 171 0.17 / 125.84 2 3
2 7 2005.72 31 14.99 2940 1366 1.54 / 127.20 2 3
3 13 1467.16 24 15.02 2271 819 2.36 / 128.02 2 3
4 13 740.00 24 15.15 1295 471 2.83 / 128.49 2 3
5 13 140.76 24 15.30 477 175 3.00 / 128.67 2 3
6 8 0.08 165 15.30 256 646 3.65 / 129.31 2 8
Average= 3.59
(KJ/cycle)

Cycle 34 GMT 3/ 9/2021 5:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 15.25 397 170 0.17 / 122.16 2 3
2 7 2007.12 31 14.97 2957 1372 1.54 / 123.53 2 3
3 13 1587.08 24 14.97 2422 870 2.41 / 124.40 2 3
4 13 698.96 24 15.17 1239 451 2.86 / 124.85 2 3
5 13 127.32 24 15.30 459 169 3.03 / 125.02 2 3
6 8 0.16 165 15.31 256 647 3.68 / 125.67 2 6
Average= 3.59
(KJ/cycle)

Cycle 33 GMT 24/ 8/2021 7:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 15.26 400 171 0.17 / 118.42 2 3
2 7 2006.72 31 14.97 2940 1364 1.54 / 119.79 2 3
3 13 1606.64 24 14.98 2438 877 2.41 / 120.66 2 4
4 13 829.08 24 15.13 1412 513 2.92 / 121.18 2 3
5 13 110.32 24 15.31 434 159 3.08 / 121.34 2 3
6 8 -0.04 165 15.30 258 651 3.74 / 121.99 2 5
Average= 3.59
(KJ/cycle)

Cycle 32 GMT 14/ 8/2021 9:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 15.26 389 166 0.17 / 114.71 2 3
2 7 2004.88 31 14.99 2934 1363 1.53 / 116.07 2 3
3 13 1581.08 24 14.98 2405 865 2.39 / 116.94 2 3
4 13 833.08 24 15.13 1415 514 2.91 / 117.45 2 5
5 13 116.32 24 15.31 439 161 3.07 / 117.61 2 3
6 8 0.04 165 15.31 253 639 3.71 / 118.25 2 8
Average= 3.58
(KJ/cycle)

Cycle 31 GMT 4/ 8/2021 12:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 28 15.26 421 180 0.18 / 110.97 2 3
2 7 2004.20 32 14.97 2944 1410 1.59 / 112.38 2 3
3 13 1580.12 24 14.99 2390 860 2.45 / 113.24 2 4
4 13 824.28 24 15.12 1406 510 2.96 / 113.75 2 3
5 13 119.36 24 15.30 439 161 3.12 / 113.91 2 3
6 8 0.08 165 15.31 251 634 3.76 / 114.54 2 7
Average= 3.58
(KJ/cycle)

Cycle 30 GMT 25/ 7/2021 14:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 28 15.26 403 172 0.17 / 107.31 2 3
2 7 2003.28 31 15.00 2935 1365 1.54 / 108.68 2 3
3 13 1569.36 24 15.00 2381 857 2.39 / 109.53 2 3
4 13 684.36 24 15.19 1214 443 2.84 / 109.98 2 4
5 13 134.24 24 15.33 460 169 3.01 / 110.15 2 3
6 8 0.04 165 15.33 254 642 3.65 / 110.79 2 9
Average= 3.57
(KJ/cycle)

Cycle 29 GMT 15/ 7/2021 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 28 15.26 396 169 0.17 / 103.58 2 3
2 7 2012.40 31 15.00 2964 1378 1.55 / 104.96 2 3
3 13 1455.48 24 15.03 2241 808 2.36 / 105.76 2 3
4 13 857.20 24 15.15 1450 527 2.88 / 106.29 2 4
5 13 187.36 24 15.31 541 199 3.08 / 106.49 2 4
6 8 0.12 165 15.32 257 650 3.73 / 107.14 2 7
Average= 3.57
(KJ/cycle)

Cycle 28 GMT 5/ 7/2021 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 15.27 401 171 0.17 / 99.95 2 3
2 7 2002.32 31 15.00 2940 1367 1.54 / 101.31 2 3
3 13 1453.76 24 15.03 2244 809 2.35 / 102.12 2 3
4 13 725.40 24 15.18 1275 465 2.81 / 102.59 2 3
5 13 130.84 24 15.33 459 169 2.98 / 102.76 2 3
6 8 -0.04 165 15.33 257 650 3.63 / 103.41 2 6
Average= 3.57
(KJ/cycle)

Cycle 27 GMT 25/ 6/2021 21: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 28 15.27 393 168 0.17 / 96.20 2 3
2 7 2003.64 31 15.00 2947 1370 1.54 / 97.57 2 3
3 13 1589.12 24 15.00 2413 869 2.41 / 98.44 2 3
4 13 805.16 24 15.16 1381 502 2.91 / 98.94 2 3
5 13 158.16 24 15.32 502 185 3.09 / 99.13 2 4
6 8 0.08 165 15.33 257 650 3.74 / 99.78 2 6
Average= 3.56
(KJ/cycle)

Cycle 26 GMT 15/ 6/2021 23:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 28 15.27 402 172 0.17 / 92.46 2 3
2 7 2006.64 31 15.01 2948 1372 1.54 / 93.83 2 3
3 13 1582.52 24 15.01 2410 868 2.41 / 94.70 2 3
4 13 795.04 24 15.17 1370 499 2.91 / 95.20 2 3
5 13 160.76 24 15.32 506 186 3.10 / 95.38 2 3
6 8 0.04 165 15.34 257 650 3.75 / 96.03 2 6
Average= 3.56
(KJ/cycle)

Cycle 25 GMT 6/ 6/2021 1:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 28 15.27 401 171 0.17 / 88.72 2 2
2 7 2002.88 31 15.00 2942 1368 1.54 / 90.09 2 3
3 13 1568.08 24 15.02 2394 863 2.40 / 90.95 2 3
4 13 788.32 24 15.18 1360 495 2.90 / 91.44 2 4
5 13 148.76 24 15.34 491 181 3.08 / 91.62 2 4
6 8 -0.08 165 15.34 261 661 3.74 / 92.28 2 10
Average= 3.55
(KJ/cycle)

Cycle 24 GMT 27/ 5/2021 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 15.28 400 171 0.17 / 84.96 2 3
2 7 2004.20 31 15.02 2935 1367 1.54 / 86.32 2 3
3 13 1583.28 24 15.02 2414 870 2.41 / 87.19 2 3
4 13 810.24 24 15.17 1394 508 2.92 / 87.70 2 3
5 13 159.80 24 15.33 509 187 3.10 / 87.89 2 4
6 8 0.08 165 15.34 260 658 3.76 / 88.55 2 9
Average= 3.54
(KJ/cycle)

Cycle 23 GMT 17/ 5/2021 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 28 15.29 399 171 0.17 / 81.19 2 3
2 7 2008.20 31 15.01 2946 1371 1.54 / 82.56 2 3
3 13 1596.92 24 15.00 2436 877 2.42 / 83.44 2 3
4 13 813.52 24 15.18 1395 508 2.93 / 83.95 2 4
5 13 168.76 24 15.33 513 189 3.12 / 84.13 2 4
6 8 0.08 165 15.34 257 650 3.77 / 84.78 2 8
Average= 3.53
(KJ/cycle)

Cycle 22 GMT 7/ 5/2021 8:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 28 15.29 392 168 0.17 / 77.50 2 3
2 7 2003.36 31 15.01 2941 1368 1.54 / 78.87 2 3
3 13 1581.60 24 15.03 2404 867 2.40 / 79.74 2 3
4 13 701.08 24 15.21 1242 453 2.86 / 80.19 2 3
5 13 130.72 24 15.34 463 170 3.03 / 80.36 2 3
6 8 0.16 165 15.35 259 656 3.68 / 81.02 2 8
Average= 3.52
(KJ/cycle)

Cycle 21 GMT 27/ 4/2021 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 28 15.28 423 181 0.18 / 73.86 2 3
2 7 2006.28 31 15.02 2960 1378 1.56 / 75.23 2 3
3 13 1456.92 24 15.05 2243 810 2.37 / 76.04 2 3
4 13 722.88 24 15.20 1271 464 2.83 / 76.51 2 3
5 13 132.12 24 15.35 466 172 3.00 / 76.68 2 4
6 8 -0.08 165 15.35 259 656 3.66 / 77.34 2 7
Average= 3.52
(KJ/cycle)

Cycle 20 GMT 17/ 4/2021 12:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 28 15.29 405 173 0.17 / 70.20 2 3
2 7 2008.16 31 15.02 2941 1369 1.54 / 71.57 2 3
3 13 1457.20 24 15.06 2244 811 2.35 / 72.38 2 3
4 13 735.20 24 15.20 1290 471 2.82 / 72.85 2 3
5 13 129.20 24 15.35 461 170 2.99 / 73.02 2 4
6 8 0.04 165 15.34 259 656 3.65 / 73.67 2 7
Average= 3.51
(KJ/cycle)

Cycle 19 GMT 7/ 4/2021 14:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 28 15.30 403 173 0.17 / 66.52 2 3
2 7 2002.84 31 15.03 2952 1375 1.55 / 67.90 2 3
3 13 1563.04 24 15.04 2380 859 2.41 / 68.76 2 3
4 13 682.28 24 15.23 1221 446 2.85 / 69.20 2 3
5 13 112.68 24 15.36 438 161 3.01 / 69.36 2 3
6 8 -0.08 165 15.36 261 661 3.68 / 70.02 2 6
Average= 3.50
(KJ/cycle)

Cycle 18 GMT 28/ 3/2021 16:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 28 15.31 421 180 0.18 / 62.83 2 3
2 7 2004.60 31 15.02 2951 1374 1.55 / 64.21 2 3
3 13 1580.28 24 15.04 2411 870 2.42 / 65.08 2 3
4 13 680.12 24 15.22 1215 444 2.87 / 65.52 2 3
5 13 110.52 24 15.37 437 161 3.03 / 65.68 2 3
6 8 -0.04 165 15.36 263 667 3.70 / 66.35 2 9
Average= 3.49
(KJ/cycle)

Cycle 17 GMT 18/ 3/2021 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 15.29 402 172 0.17 / 59.09 2 3
2 7 2003.72 31 15.04 2943 1372 1.54 / 60.47 2 3
3 13 1590.56 24 15.04 2420 874 2.42 / 61.34 2 3
4 13 800.24 24 15.20 1372 501 2.92 / 61.84 2 3
5 13 102.08 24 15.38 423 156 3.07 / 62.00 2 4
6 8 -0.04 165 15.36 259 656 3.73 / 62.65 2 9
Average= 3.48
(KJ/cycle)

Cycle 16 GMT 8/ 3/2021 21:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 27 15.32 394 163 0.16 / 55.26 2 3
2 7 2005.04 31 15.04 2929 1366 1.53 / 56.63 2 3
3 13 1590.00 24 15.04 2424 875 2.40 / 57.50 2 3
4 13 952.96 24 15.17 1579 575 2.98 / 58.08 2 4
5 13 155.40 24 15.35 498 183 3.16 / 58.26 2 3
6 8 0.08 165 15.36 261 661 3.82 / 58.92 2 7
Average= 3.47
(KJ/cycle)

Cycle 15 GMT 26/ 2/2021 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 27 15.32 395 163 0.16 / 51.60 2 3
2 7 2004.40 31 15.04 2936 1369 1.53 / 52.97 2 3
3 13 1457.16 24 15.08 2245 813 2.34 / 53.78 2 3
4 13 838.52 24 15.20 1420 518 2.86 / 54.30 2 3
5 13 103.16 24 15.39 421 156 3.02 / 54.46 2 4
6 8 -0.20 165 15.37 253 642 3.66 / 55.10 2 8
Average= 3.44
(KJ/cycle)

Cycle 14 GMT 17/ 2/2021 1:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 27 15.33 394 163 0.16 / 47.98 2 3
2 7 2010.04 31 15.07 2957 1381 1.54 / 49.36 2 3
3 13 1460.88 24 15.09 2250 815 2.36 / 50.18 2 3
4 13 709.68 24 15.24 1248 456 2.82 / 50.63 2 3
5 13 117.16 24 15.38 439 162 2.98 / 50.80 2 4
6 8 0.04 165 15.38 253 642 3.62 / 51.44 2 7
Average= 3.43
(KJ/cycle)

Cycle 13 GMT 7/ 2/2021 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 27 15.31 397 164 0.16 / 44.32 2 3
2 7 2006.24 31 15.04 2936 1369 1.53 / 45.69 2 3
3 13 1586.60 24 15.05 2413 872 2.40 / 46.56 2 3
4 13 688.96 24 15.23 1221 446 2.85 / 47.01 2 3
5 13 117.20 24 15.38 443 164 3.01 / 47.17 2 3
6 8 0.20 165 15.37 256 649 3.66 / 47.82 2 6
Average= 3.42
(KJ/cycle)

Cycle 12 GMT 28/ 1/2021 5:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 27 15.33 391 162 0.16 / 40.66 2 3
2 7 2007.36 31 15.05 2950 1376 1.54 / 42.03 2 3
3 13 1578.84 24 15.07 2395 866 2.40 / 42.90 2 3
4 13 705.76 24 15.25 1240 454 2.86 / 43.35 2 4
5 13 113.16 24 15.38 433 160 3.02 / 43.51 2 3
6 8 0.16 165 15.38 253 642 3.66 / 44.15 2 8
Average= 3.40
(KJ/cycle)

Cycle 11 GMT 18/ 1/2021 8: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 27 15.32 393 163 0.16 / 36.96 2 3
2 7 2002.92 31 15.07 2948 1377 1.54 / 38.33 2 3
3 13 1476.32 24 15.10 2267 822 2.36 / 39.15 2 3
4 13 872.76 24 15.19 1468 535 2.90 / 39.69 2 4
5 13 114.44 24 15.39 438 162 3.06 / 39.85 2 4
6 8 0.04 165 15.39 253 642 3.70 / 40.49 2 9
Average= 3.37
(KJ/cycle)

Cycle 10 GMT 8/ 1/2021 10:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 27 15.31 405 167 0.17 / 33.19 2 3
2 7 2009.88 32 15.05 2949 1420 1.59 / 34.61 2 3
3 13 1596.52 24 15.06 2421 875 2.46 / 35.49 2 3
4 13 820.12 24 15.21 1398 510 2.97 / 36.00 2 4
5 13 103.48 24 15.39 419 155 3.13 / 36.15 2 4
6 8 0.12 165 15.38 253 642 3.77 / 36.79 2 6
Average= 3.34
(KJ/cycle)

Cycle 9 GMT 29/12/2020 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 27 15.33 389 161 0.16 / 29.48 2 3
2 7 2007.68 31 15.05 2934 1369 1.53 / 30.85 2 3
3 13 1585.68 24 15.06 2385 862 2.39 / 31.71 2 3
4 13 799.00 24 15.21 1372 501 2.89 / 32.21 2 3
5 13 137.88 24 15.38 471 174 3.07 / 32.39 2 3
6 8 0.04 165 15.38 251 637 3.70 / 33.02 2 7
Average= 3.30
(KJ/cycle)

Cycle 8 GMT 19/12/2020 14:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 27 15.32 386 160 0.16 / 25.90 2 3
2 7 2008.80 38 15.01 2939 1676 1.84 / 27.58 2 3
3 13 1280.44 18 15.14 2008 547 2.38 / 28.12 2 3
4 13 708.44 18 15.25 1251 343 2.73 / 28.47 2 3
5 13 150.80 18 15.39 486 135 2.86 / 28.60 2 3
6 13 39.96 18 15.40 320 89 2.95 / 28.69 2 3
7 8 0.08 165 15.37 248 629 3.58 / 29.32 2 10
Average= 3.26
(KJ/cycle)

Cycle 7 GMT 9/12/2020 16: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 27 15.34 391 162 0.16 / 22.27 2 3
2 7 2008.88 39 15.01 2928 1714 1.88 / 23.98 2 3
3 13 1384.48 18 15.12 2144 584 2.46 / 24.56 2 3
4 13 671.52 18 15.28 1197 329 2.79 / 24.89 2 3
5 13 140.08 18 15.39 470 130 2.92 / 25.02 2 3
6 13 40.76 18 15.41 320 89 3.01 / 25.11 2 3
7 8 0.12 165 15.39 248 630 3.64 / 25.74 2 9
Average= 3.22
(KJ/cycle)

Cycle 6 GMT 29/11/2020 18: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 26 15.32 389 155 0.15 / 18.66 2 3
2 3 1029.28 1 15.36 1715 26 0.18 / 18.69 2 3
3 7 2008.40 38 15.02 2933 1674 1.86 / 20.36 2 3
4 13 1275.76 18 15.15 2001 546 2.40 / 20.91 2 3
5 13 715.84 18 15.26 1259 346 2.75 / 21.25 2 3
6 13 152.28 18 15.39 484 134 2.88 / 21.39 2 3
7 13 40.40 18 15.41 318 88 2.97 / 21.47 2 3
8 8 0.20 165 15.39 248 630 3.60 / 22.10 2 12
Average= 3.16
(KJ/cycle)

Cycle 5 GMT 19/11/2020 20: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 29 15.34 386 172 0.17 / 15.02 2 3
2 3 899.68 -3 15.65 0 0 0.00 / 15.02 2 3
3 7 2005.92 38 15.01 2927 1670 1.84 / 16.69 2 3
4 13 1385.00 18 15.12 2140 582 2.42 / 17.27 2 3
5 13 787.00 18 15.24 1349 370 2.79 / 17.64 2 3
6 13 180.92 18 15.39 524 145 2.94 / 17.78 2 3
7 13 48.64 18 15.40 333 92 3.03 / 17.88 2 3
8 8 0.04 165 15.38 248 629 3.66 / 18.51 2 8
Average= 3.08
(KJ/cycle)

Cycle 4 GMT 9/11/2020 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 26 15.33 385 153 0.15 / 11.42 2 3
2 3 1021.40 1 15.40 1718 26 0.18 / 11.44 2 3
3 7 1516.96 74 15.09 2288 2555 2.73 / 14.00 2 3
4 13 140.56 18 15.41 468 130 2.86 / 14.13 2 3
5 13 44.24 18 15.42 324 90 2.95 / 14.22 2 3
6 8 0.04 165 15.40 246 625 3.58 / 14.84 2 10
Average= 2.97
(KJ/cycle)

Cycle 3 GMT 8/11/2020 22:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 23 15.34 383 135 0.14 / 7.78 2 3
2 10 1011.84 3 15.29 1675 77 0.21 / 7.86 2 2
3 7 1508.24 74 15.08 2273 2536 2.75 / 10.40 2 3
4 13 189.76 18 15.40 533 148 2.90 / 10.55 2 3
5 13 47.56 18 15.42 331 92 2.99 / 10.64 2 3
6 8 0.00 165 15.40 247 628 3.62 / 11.26 2 8
Average= 2.82
(KJ/cycle)

Cycle 2 GMT 7/11/2020 22:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 30 15.38 389 179 0.18 / 4.27 2 3
2 3 829.32 -3 15.66 0 0 0.00 / 4.27 2 3
3 3 908.56 -2 15.67 0 0 0.00 / 4.27 2 3
4 7 1519.16 74 15.08 2284 2549 2.73 / 6.82 2 4
5 13 143.28 18 15.40 465 129 2.86 / 6.95 2 3
6 13 40.36 18 15.41 312 87 2.94 / 7.03 2 3
7 8 0.04 165 15.39 243 617 3.56 / 7.65 2 10
Average= 2.55
(KJ/cycle)

Cycle 1 GMT 6/11/2020 22:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 27 15.50 351 147 0.15 / 1.63 3 3
2 3 961.04 -1 15.68 0 0 0.00 / 1.63 3 3
3 7 993.60 75 15.25 1596 1825 1.97 / 3.46 2 3
4 8 0.12 165 15.45 247 630 2.60 / 4.09 2 9
Average= 2.04
(KJ/cycle)

Cycle 0 GMT 6/11/2020 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.08 26 15.64 432 176 0.18 / 0.18 3 3
2 7 165.68 74 15.61 442 511 0.69 / 0.69 3 3
3 8 -0.00 240 15.58 214 800 1.49 / 1.49 3 28
Average= 1.49
(KJ/cycle)